Overview of MSRR, SERC Building, and Security Planning NRC Docket Number 50-610 Dr. Rusty Towell NEXT Lab Director, Abilene Christian University April 13, 2023

2 Molten Salt Research Reactor is Simplified MSRE The Molten Salt Reactor Experiment operated at ORNL from 1965-1969 on U-235 and U-233.

© 2023 Abilene Christian University

MSRR: simplified concepts 19.75% instead of 33% 235U 1 MWth instead of 8-10 MWth SS-316 instead of Hastelloy-N No freeze valve Utilizing 50 years of technology advancement MSRE: shared concepts UF4LiF-BeF2fuel Loop design Graphite moderator Drain tank Trench-based radiation protection 5-years of full-power operation

© 2023 Abilene Christian University

Science and Engineering Research Center

  • 28,000 ft2 facility
  • 6, 000 ft2 Research Bay
  • Specialty Research Labs
  • Offices
  • Design completed by Parkhill
  • Linbeck construction company
  • Design Completed: 2021
  • Begin Construction:

2022

  • Completed:

2023

© 2023 Abilene Christian University

© 2023 Abilene Christian University

6

© 2023 Abilene Christian University

80 15 25 40t Crane 120 50

© 2023 Abilene Christian University

8

© 2023 Abilene Christian University

9

© 2023 Abilene Christian University

10

© 2023 Abilene Christian University

11

© 2023 Abilene Christian University

12

© 2023 Abilene Christian University

13

© 2023 Abilene Christian University

14

© 2023 Abilene Christian University

© 2023 Abilene Christian University

April 13, 2023 ACU MSRR and SERC Overview 16

© 2023 Abilene Christian University

17

© 2023 Abilene Christian University

Full-service law enforcement agency

  • 24/7/365 operations
  • 14 Full-time Police Officers/6 Civilian Staff
  • All ACUPD officers are fully certified/armed Texas police officers
  • Formal Working Agreement w/ Abilene Police Dept.
  • Joint 800 MHz radios system/dispatch
  • Full jurisdiction on/off-campus
  • Primary Response 24/7 to area Alarms
  • Close working relationship with local, State DPS, FBI April 13, 2023 ACU MSRR and SERC Overview 18 ACU Police Department

© 2023 Abilene Christian University

April 13, 2023 ACU MSRR and SERC Overview 19

  • 287 Combined (Sworn & Civilian )
  • Recognized Agency-Texas Police Chiefs Association
  • Event Response:
  • Co-Jurisdiction with ACUPD
  • Backup for Alarm Response Procedure
  • Formal Joint-operations Agreement w/

ACUPD

  • Close relationship/Info Sharing with all local, State, and federal agencies City of Abilene Police Department

© 2023 Abilene Christian University

April 13, 2023 ACU MSRR and SERC Overview 20

  • Anticipated SNM license inventory:
  • 500 kg U
  • HALUE (enrichment less than 20%)
  • Small Unirradiated SNM inventory after initial startup:
  • Physical Form of SNM MSRR Design Features: Fuel

© 2023 Abilene Christian University

April 13, 2023 ACU MSRR and SERC Overview 21

  • Facility security
  • Barriers to access:
  • Access control
  • Intrusion detectors
  • Alarmed response
  • Containment of SNM/fission products:
  • Multiple barriers
  • Salt
  • Primary Salt Loop
  • Reactor Enclosure
  • Massive shielding
  • Off Gas System
  • Information Technology Security (Cybersecurity)

MSRR Design Features: Facility

© 2023 Abilene Christian University

THANK YOU acunextlab.org 22

© 2023 Abilene Christian University