DOCUMENT DATE:
TITLE:
CASE
REFERENCE:
KEYWORD:
ADAMS Template: SECY-067 02/12/1997 PR-002, 040, 070, AND 076 - 62FR06672 - USEC PRIVATIZATION ACT: CERTIFICATION AND LICENSING OF URANIUM ENRICHMENT FACILITIES PR-002, 040, 070, AND 076 62FR06672 RULEMAKING COMMENTS Document Sensitivity: Non-sensitive - SUNSI Review Complete
STATUS OF RULEMAKING PROPOSED RULE :
PR-002, 040, 070, AND 076 OPEN ITEM (Y/N) N RULE NAME:
USEC PRIVATIZATION ACT:
CERTIFICATION AND LICENSING OF URANIUM ENRICHMENT FACILITIES PROPOSED RULE FED REG CITE:
62FR06672 PROPOSED RULE PUBLICATION DATE:
02/12/ 97 ORIGINAL DATE FOR COMMENTS: 03 / 14/ 97 NUMBER OF COMMENTS:
EXTENSION DATE:
I I
1 FINAL RULE FED. REG. CITE: 62FR06664 FINAL RULE PUBLICATION DATE: 02 / 12 / 97 NOTES ON: AMENDING REGS TO CONFORM TO CHANGES IN ATOMIC ENERGY ACT OF 1954.
STATUS PRINCIPAL EFFECT OF LEGISLATION IS TO DIRECT BOARD OF DIRECTORS OF OF RULE:
USEC TO SELL ASSETS TO PRIVATE SECTOR ENTITY.
FILE ON Pl.
HISTORY OF THE RULE PART AFFECTED: PR-002, 040, 070, AND 076 RULE TITLE:
USEC PRIVATIZATION ACT:
CERTIFICATION AND LICENSING OF URANIUM ENRICHMENT FACILITIES PROPOSED RULE PROPOSED RULE DATE PROPOSED RULE SECY PAPER: 96-258 SRM DATE:
01/22/ 97 SIGNED BY SECRETARY:
FINAL RULE FINAL RULE DATE FINAL RULE SECY PAPER: 96-258 SRM DATE:
01/22 / 97 SIGNED BY SECRETARY:
STAFF CONTACTS ON THE RULE CONTACT!: CHARLES W. NILSEN MAIL STOP: T-9-F31 PHONE:
CONTACT2: CAROL GALLAGHER MAIL STOP: T-9-F29 PHONE:
02 / 06 / 97 02 / 06 / 97 415-6209 415-5905
DOCKET NO. PR-002, 040, 070, AND 076 (62FR06672)
In the Matter of USEC PRIVATIZATION ACT: CERTIFICATION AND LICENSING OF URANIUM ENRICHMENT FACILITIES DATE DATE OF TITLE OR DOCKETED DOCUMENT DESCRIPTION OF DOCUMENT 02/10/97 02/10/97 03/14/97 04/01/97 02/06/97 02/06/97 03/14/97 03/27/97 FEDERAL REGISTER NOTICE - PROPOSED RULE FEDERAL REGISTER NOTICE - DIRECT FINAL RULE COMMENT OF UNITED STATES ENRICHMENT CORPORATION (ROBERT L. WOOLLEY) (
- 1)
LTR ROBERT L. WOOLLEY OF UNITED STATES ENRICHMENT CORPORATION WITHDRAWING COMMENT NO. 1
us United States Enrichment Corporation DOCKETED USNRC
- 97 APR -1 A 9 :50 Jlf,flCE 017 ~ECRETARY March 27, 11'.fOCKETING l SE VICE BRAHC United States Enrichment Corporation 2 Democracy Center 6903 Rockledge Drive Bethesda, MD 20817 Tel: (301) 564-3200 Fax: (301) 564-3201 Secretary SERIAL: GDP 97-0045 U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Attention: Docketing and Service Branch Paducah Gaseous Diffusion Plant (PGDP)
Portsmouth Gaseous Diffusion Plant (PORTS)
Docket Nos. 70-7001 and 70-7002 DOCKET NUMBER PROPOSED RULE PR 2. J./ 0, 10.J 7 L
(~a f/?./,fo1i) I Modification of USEC Comments on NRC Direct Final Rulemaking Regarding "USEC Privatization Act: Certification and Licensing of Uranium Enrichment Facilities," 62 Fed.
Reg. 6667 (February 12, 1997)
Dear Sir:
By letter dated March 14, 1997 (Serial: GDP 97-0030), the United States Enrichment Corporation (USEC) provided its comments on the NRC's Direct Final Rulemaking implementing the USEC Privatization Act. USEC supported the proposed rule changes, but recommended that the NRC delete 10 CFR § 76.53. USEC continues to support the proposed rule, but wishes to withdraw its recommendation that section 76.53 be deleted from the regulations. We are therefore requesting no change in the rule as published for comment by the NRC.
If you have any questions, please contact me at (301) 564-3413 or Ms. Lisamarie Jarriel at (301) 564-3247.
Sincerely,
@{:Lfl~
Robert L. Woolley Nuclear Regulatory Assurance and Policy Manager Offices in Paducah, Kentucky Portsmouth, Ohio Washington, DC
J.S. NUCLEAR REGULATORY COMMIS~IOrt DOCKETING & SERVICE SECTION OFFICE OF THE SECRETARY OF THE COMMISSION Document Statistics Postmark Date
.3 / :J '1 / 9 '7 Copies Received. _
_ /_-.-__
,\dd'I Copies,9eproduced __ 1/-'----
Special Distribution_
IV! Jim - -
Gall~ffier; 1>1)~ 1<rps
us United States Enrichment Corporation Secretary US Nuclear Regulatory Commission Washington, D.C. 20555-0001 Attention: Docketing and Service Branch March 14, 1997 Paducah Gaseous Diffusion Plant (PGDP)
Portsmouth Gaseous Diffusion Plant (PORTS)
Docket Nos. 70-7001 and 70-7002 United States
(!)
Enrichment Corporation 2 Democracy Center 6903 Rockledge Drive Bethesda, MD 20817 Tel (301) 564-3200 Fax: (301) 564-3201 SERIAL: GDP 97-0030 USEC Comments on NRC Direct Final Rulemaking Regarding "USEC Privatization Act:
Certification and Licensing of Uranium Enrichment Facilities," 62 Fed. Reg. 6667 (February 12, 1997)
Dear Sir:
On behalf of the United States Enrichment Corporation (USEC), I am pleased to provide comments on the NRC's Direct Final Rulemaking implementing the USEC Privatization Act. USEC has no "significant adverse" comments that would, under the NRC's notice, warrant any delay in the effective date of the rule changes. Indeed, USEC supports the proposed rule changes and commends the NRC for its expeditious development of regulatory changes implementing the requirements of the USEC Privatization Act.
We have identified one provision of the Privatization Act that does not appear to have been incorporated into the language of the Direct Final Rule. The Energy Policy Act of 1992, among other things, added section 1701(c)(2) to the Atomic Energy Act (AEA) specifying that the NRC "in consultation with the Environmental Protection Agency, shall review any... application [for a certificate of compliance]... " The NRC implemented this provision in 10 CFR § 76.53, which mandates that the Director of NMSS "consult with" EPA and solicit EPA's written comments on certification applications.
Section 3116 of the USEC Privatization Act, however, amends section 1701(c)(2) of the AEA by eliminating the requirement for NRC consultation with EPA on the certificate of compliance applications. As amended, section 1701(c)(2) simply states that the NRC "shall review any such application... " The Direct Final Rulemaking package does not explicitly address this aspect of the Privatization Act.
MAR 2 O 1997
~cknowledged by card *NIIIJIIUEI v*aew..-i a,*
Offices in Paducah, Kentucky Portsmouth, Ohio Washington, DC
t,S. NUCLEAR REGULATORY OMM1S~10~
DOCKETll'G &
ION OFFICE OF-Y OFT =
Cop:..,s R
\d1 I Co C JC-21 u I iJ:...~: 1
~=-!LI---
G~,~
~,........ -r--'-~'~P5=-_
Docketing and Service Branch March 14, 1997 GDP 97-0030 Page 2 USEC does not object to, and indeed, encourages the NRC to consult with the EPA whenever the NRC determines such consultation would be appropriate and helpful. However, the regulation should be changed to reflect the changes to section l 70l(c)(2).
Deletion of 76.53 would implement the statutory change while maintaining the NRC's discretion to consult with EPA as necessary.
We would be pleased to discuss this comment with you. Please contact me at (301) 564-3413 or Ms. Lisamarie Jarriel at (301) 564-3247.
Sincerely,
~
Q l<'oJt \ f.,--
Robert L. Woolley Nuclear Regulatory Assurance and Policy Manager
1997,03-14 15: 10
- 334 P,02/03 FROM :USEC USEC United States Enrichment Corpor-.:ition 301-564-3210 DOCKETED USNRC "97 MAR 14 P 3 :33 OFFICE OF S CRE~ RYE DOCKET! G &. SERvlC BRANCH Un~St~
Ennc:,mer-C-~cr--:D10n 2 ~.Cf C?m:r 690i~k~~
Betresr;:a. tAO 2e-:-
TeL *301 I Sii4-32:J; Fax. 301) :64--32C:-
DOCKET NU BER (f)
PROPOSED RULE 1
~. '70. 10 r 7 h March 14, 1997
( h ~ FR lt,h'l.2-)
Secretary US Nuclear Regulatory Commission Washington, D.C. 20555-0001 Attention: Docketing and Service Branch Paducah Gaseous Diffusion Plant (PGDP)
Portsmouth Ga.<<ieous Diffusion Plant (PORTS)
Docket Nos. 70-7001 and 70-7002 SElUAL: GDP 97-0030 USEC Comments on NRC Db-ect Final Rnlemaking Regarding 19USEC Privatization Act:
Certification and Licensing of Uranium Enrichment Facilities," 62 Fed. Reg. 6667 (February 12, 1997)
Dear Sir:
On behalf of the United States Enrichment Corporation (USEC). tam pleased to provide commems on the NRC's Direct Final Rulemaking implementing the USEC Privatization Act. USEC has no "significant adverse" comments that would, under the NR.C's notice, warrant any delay in the effective date of the rule changes. Indeed. USEC supports the proposed IUle changes and commends the N.RC for its expeditious development of regulatory changes implementing the requirements of the USEC Privatization Act.
We have identified one provision of the Privatization Act that does not appear to have been incorporated into the language of the Direct Final Rule. The Energy Policy Act of 1992, among other things, added section 170I(c)(2) to the Atomic Energy Act (AEA) specifying that the NRC '"in consultation with the Environmental Protection Agency, shall review any... application [for a certificate of compliance].,." The NRC implemented this provision in 10 CFR § 76.53, which mandates that the Director of NMSS "consult with" EPA and solicit EP A's written comments on certification applications.
Section 3116 of the USEC Privatization Act, however, amends section 1701(c)(2) of the AEA by eliminating the requirement for NRC consultation with BP A on the certificate of compliance applications. As amended, section 1701(c)(2) simply states that the NRC shall review any such application... " The Direct Final Rulemaking package does not explicitly address this aspect of the Privatization Act.
i-S. NUCLEAR REGULATORY COMMl~~IU DOCKETING & SERVICE SECTION OFFICE OF THE SECRETARY OF THE COMMISSION Do ument Statisti s Postmark Date lJY) 3/<1/97 ( ~
.2 J~ ~)
Copies Recelved_~
,\dd'I Copie~*9ep Sp *
- *
- ri
. Se.
__,,,,.__,__:....:..;..,,..Cj..L.L.'<e'-'-Y--~ 1?1> e I n,i, D
~
FROM : USEC Docketing and Service Branch March 14, 1997 GDP 97...()030 Page 2 301-564-3210 1997, 03-14 15:1 1
- 334 P, 03/03 USEC does not object to, and indeed, encourages the NR.C to consult with the EPA whenever the NRC determines such consultation would be appropriate and helpful. However, the regulation should be changed to reflect the changes to section I70l(c)(2). Deletion of 76.53 would implement the statutory change while maintaining the NRC's discretion to consult with EPA as necessary.
We would be pleased to discuss this comment with you. Please contact me at (301) 564-3413 or Ms. Lisamarie Jarriel at (301) 564-3247.
Sincerely, S: 0 r'<oJT~ f.,,,
Robert L. Woolley Nuclear Regulatory Assurance and Policy Manager
DOCKET NUMBER PROPOSED A LP" 61 ~D,, '10 1-7b
( lR:). F"~ (piP1~)
NUCLEAR REGULATORY COMMISSION 10 CFR Parts 2, 40, 70, and 76 RIN: 3150-AF56 USEC Privatization Act AGENCY:
Nuclear Regulatory Commission.
ACTION:
Direct final rule.
DOCKETED USNRC
[7590-01-P]
"97 FEB 10 Al0 :54 OFFICE OF SEC E R OOCKETlt
&. S f VIC:
BRANCH
SUMMARY
The Nuclear Regulatory Commission (NRC) is amending its regulations concerning the certification and licensing of uranium enrichment facilities to conform to changes made to the Atomic Energy Act of 1954, as amended (the Act), by the USEC Privatization Act legislation. Although the principal effect of this legislation is to direct the Board of Directors of the United States Enrichment Corporation (USEC) to sell the assets of the USEC to a private sector entity, this legislation also amended the Act with respect to NRC certification of gaseous diffusion plants leased by USEC and the licensing of atomic vapor laser isotope separation (AVLIS) technology.
USEC is responsible for the operation of the two gaseous diffusion plants and the development of the AVLIS technology.
The legislation requires that AVLIS uranium enrichment facilities be licensed subject to the provisions of the Act pertaining to source material and special nuclear material rather than under the provisions pertaining to a production facility; provides for the issuance of civil penalties to USEC or its successor for failure to comply with regulatory requirements governing the operation of gaseous diffusion plants; prohibits issuance of a f µ,1y_ fiYI ~ /1 ~ I q 1 at IRA Ff{ vi,"' c./
license/certificate to the Corporation or its successor if it is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government, or if its issuance would be inimical to the common defense and security of the United States or to the maintenance of a reliable and economical domestic source of enrichment services; and eliminates the annual requirement that the Commission certify that USEC or its successor is in compliance with NRC regulations.
The Commission may determine how frequently USEC or its successor must submit a recertification application to the NRC, provided that the NRC recertify USEC's or its successor's compliance with its regulations not less frequently than every five years. The adopted rule changes bring the current regulations into conformance with these provi~ions.
~
11, /C/'1 1 DATE:
The final rule is effective on [iAsert date iQ days after ~~elieation]
~
t'l-1 l9'11 unless significant adverse comments are received by [iAnrt data 30 da:)', after publicatiofti. If the effective date is delayed, timely notice will be published in the Federal Register.
ADDRESSES:
Mail written comments to:
The Secretary, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.
ATTN:
Docketing and Service Branch.
Hand deliver comments to:
11555 Rockville Pike, Rockville, MD, between 7:30 am and 4:15 pm on Federal workdays.
For information on submitting comments electronically, see the discussion under Electronic Access in the Supplementary Information Section.
Copies of comments received may be examined or copied for a fee at the NRC Public Document Room, 2120 L Street NW. (Lower Level), Washington, DC.
2
FOR FURTHER INFORMATION CONTACT:
Mr. C. W. Nilsen, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, telephone (301) 415-6209.
SUPPLEMENTARY INFORMATION:
Background
On April 26, 1996, President Clinton signed legislation that provides for fiscal year (FY) 1996 appropriations to a number of Federal agencies (H.R.
3019 (Pub. L. 104-134)).
Included within the legislation is Title Ill, Chapter 1, entitled *usEC Privatization Act,* which directs the Board of Directors of the United States Enrichment Corporation (USEC) to sell the assets of the USEC to a private sector entity. The private sector corporation that purchases the assets of USEC will be responsible for the operation of the gaseous diffusion plants known as the Portsmouth Plant and the Paducah Plant, located at Piketon, Ohio, and Paducah, Kentucky, respectively, and the development of the atomic vapor laser isotope separation (AVLIS) technology.
In addition, the legislation amended the Atomtc Energy Act of 1954, as amended (the Act), with respect to the certification of gaseous diffusion plants and licensing of an AVLIS uranium enrichment facility. The gaseous diffusion plants are regulated under 10 CFR Part 76, "Certification of Gaseous Diffusion Plants." Operation of an AVLIS uranium enrichment facility will be licensed under 10 CFR Parts 40, "Domestic Licensing of Source material* and 70,
- Domestic Licensing of Special Nuclear Material.*
3
Discussion A principal effect of Pub. L. 104-134 on NRC licensing actions is that the referenced AVLIS uranium enrichment facilities will be licensed pursuant to the provisions of the Act pertaining to source material and special nuclear material rather than the provisions pertaining to a production facility.
Under this legislation, AVLIS licensing will be a single-step licensing process with one license issued pursuant to 10 CFR Parts 40 and 70, rather than a two-step licensing process under 10 CFR Part 50.
The regulations previously were amended on April 30, 1992 (57 FR 18388) to conform with the "Solar, Wind, Waste, and Geothermal Power Production Incentives Act of 1990,"
(Pub. L. 101-575) by providing a single-step process for licensing uranium enrichment.
The April 30, 1992 amendments also made 10 CFR Part 70 the basic regulation for licensing a uranium enrichment facility. Although the 1990 legislation specifically excluded AVLIS uranium enrichment, then under development by the Department of Energy, from the one-step licensing process, Pub. L. 104-134 made the development of AVLIS a responsibility of USEC (which will become a private entity as a result of this legislation) and removed the exclusion of AVLIS from one-step licensing. Therefore, licensing of AVLIS, as with other licensed uranium enrichment facilities, will be a one-step process requiring an environmental review, adjudicatory hearing, inspection before operation, and third party liability insurance. However, for other purposes of the Act, such as controlling the export of specially designed or prepared uranium enrichment equipment.and preservation of Federal authority in Agreement States, all uranium enrichment facilities regulated by the NRC 4
remain under the Atomic Energy Act provisions for production facilities.
Specific implementing amendments are as follows:
In 10 CFR 70.1, "Purpose" is revised to indicate that all uranium enrichment facilities requiring a license will be licensed under 10 CFR Part 70, "Domestic Licensing of Special Nuclear Material."
In 10 CFR 40.4 and 70.4, "Definitions* the term Corporation is added to refer appropriately to the licensing-of ttle Corporation* or its s-uccessor for
- operation of an AVLIS facility.
In 10 CFR 76.4, "Definitions" the term Corporation is amended to include the successor to USEC.
In addition, in confonnance with the 1996 legislation, provisions;,:are made in 10 CFR Parts 2 and 76 to allow the NRC to impose civil penalties on the USEC or its successor for failure to comply with regulatory requirements governing the operation of the gaseous diffusion plants regulated under 10 CFR Part 76.
Civil penalty authority presently contained in 10 CFR Part 70 would apply to AVLIS licensing. Furthennore, the "General Statement of Policy and Procedures for NRC Enforcement Actiona NUREG-1600, is being supplemented to provide examples of violations in each of the four severity levels as guidance in detennining the appropriate severity level for violations in the area of gaseous diffusion plant operations. Specific implementing amendments are as follows:
In 10 CFR 2.200(a) concerning the scope of Subpart B of Part 2, a new sentence is added to read as follows:
- However, with regard to the holder of a Part 76 Certificate of Compliance or Compliance Plan, except for civil penalty procedures in this subpart, the applicable procedures.are set forth in
§ 76.70." This will clarify that the provisions governing the issuance of an 5
order or notice of violation to the holder of a certificate of compliance or compliance plan under 10 CFR Part 76 are contained in§ 76.70 but the civil penalty procedures in subpart B of Part 2 are applicable to these entities.
In 10 CFR 2.205{a), a reference to the§ 76.70{d), "notice of violation,* and a reference to the provisions of a 10 CFR Part 76,
- certificate of compliance or compliance plan," are added because the Connnission now has authority to issue civil penalties to the Corporation for violation of its regulations.
Similarly, in 10 CFR 76.l0{b), the last phrase, *except, that the Corporation is not subject to the authority of Section 234 of the Act," is eliminated because the Corporation is now subject to Section 234 of the Act.
10 CFR 76.60 {c){l) and {d)(l) are removed.
These paragraph designations are reserved and the last phrase of§ 76.60{i), *provided, however, that civil penalties shall not be imposed on the Corporation pursuant to.§ 95.61 of this chapter except for violations of Section 206 of the Energy Reorganization Act" is also eliminated. These prohibitions on issuing civil penalties are removed to pennit the imposition of civil penalties.
In 10. CFR 76.72{d), a reference to the new Section 234 civil penalty authority is added.
e The 10 CFR 76.131{a){3) reference to Title XI of the Energy Policy Act of 1992, is eliminated because this act's applicable provisions were amendments, to the Atomic Energy Act of 1954.
Reference to Section 206 of the Energy Reorganization Act has been relocated from§ 76.13l{b) to paragraph
{b){2). References to violations under Section 234 of the Atomic Energy Act of 1954, as amended, and specific references to sections of the Act are added as paragraphs {b){l), {b){3), and {b){4) to describe _the new civil penalty authority.
6
A provision is also added stating that the Commission will not issue a license or certificate to the Corporation or its successor if the Corrmission finds that the Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government, or that issuance would be inimical to the common defense and security of the United States or to the maintenance of a reliable and economical domestic source of enrichment services. This provi-sion is added to conform with the legislation which includes specific language that restricts issuance of a certificate or a license to the USEC or its successor if the issuance would be inimical to the maintenance of a reliable and economical domestic source of enrichment services. Heretofore, the Commission has not been asked in its regulatory decisions to evaluate whether a proposed action is inimical to the viability of the domestic industries subject to NRC's regulation.
Information about the intent of the language is contained in a Senate Committee report on an earlier version of the legislation (S. Rpt. No. 104-173 on S.755, November 17, 1995),
which states that the provision is to *guard against the possibility of a foreign uranium enrichment company acquiring the Corporation with the intent of operating it in such a manner inconsistent with its maintenance as an ongoing uranium enrichment concern." The report further states that no certificate or license should be issued "if in the opinion of the NRC the issuance of such a license or certificate of compliance would be inimical to the co11111on defense and security of the United States or would be inimical to the maintenance of a reliable and economical domestic source of enrichment services because of the nature and extent of the ownership, control, or domination of the Corporation by a foreign corporation or a foreign government or any other relevant factors or circumstances.*
7
To comply with this provision of the 1996 legislation, the NRC staff will evaluate this restriction on certification and licensing based, in ~art, on the following:
Information required under §§.70.22 and 76.33 "infonnation known to the applicant concerning the control or ownership, if any, exercised over the applicant by any alien, foreign corporation, or foreign government."
- Information to be obtained under a proposed rule (61 FR.40555; August 5, 1996) ~mending the provisions of 10 CFR Parts 25 and 95 that deal with requirements for access to and protection of classified information. (The Corrmission expects to adopt this proposed rule as a final rule in January of 1997.) These amendments were proposed to conform the NRC's regulations*with the nationally applicable requirements for the protection of and access to classified National Security Information, which have been revised through the issuance of the National Industrial Security Program Operating Manual (NISPOM), published January 1995; Executive Order 12958, "Classified National Security Infonnation," dated April 17, 1995; and Executive Order 12968, "Access to Classified Information," dated August 4, 1995. Specifically, as related to foreign ownership, control, or domination, the NISPOM provides criteria for determining whether U.S. companies handling classified material are under foreign ownership, control, or influence (FOCI).
FOCI requirements established in proposed revisions to 10 CFR Part 95 are considered useful to the subject finding the Corrmission must make under the provisions of the 1996 legislation. This is especially so based upon the sensitive nature of the facilittes and USEC's role,* and the fact that USEC will have access to classified information and equipment.
8
Further, the existing regulations(§§ 40.3l(b), 70.22(d), and 76.33(d))
reflect NRC authority under the Atomic Energy Act to require that an applicant, licensee, or certificate holder submit additional information concerning issuance of a license or certificate. Therefore, under these provisions USEC also may be required to submit additional information addressing whether issuance would be inimical to the maintenan~e of a reliable and economical domestic sourc~uf enrichment ~ervices. - The staff is*
considering whether there are specific additional information needs and will reconanend to the Co11111ission whether further amendments to the regulations are warranted.
In addition the staff is preparing procedures for developing the required annual report to Congress and guidance for recertification, and, developing procedures to consider the issues of foreign ownership_ and control, and inimicalness to the co111110n defense and security and to a reliable and economical supply of domestic enrichments services. Specific implementing amendments are as follows:
New sections 10 CFR 40.38 and 70.40 entitled "Ineligibility of certain applicants," are added to state that the NRC will not issue a license to operate an AVLIS enrichment facility to the Corporation if:
(1) It is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; (2) Issuance would be inimical to the co11111on defense and security of the United States; or (3) Issuance would be inimical to the maintenance of a reliable and economical domestic source of enrichment services.
9
A new section 10 CFR 76.22 entitled "Ine1fgibi1ity of certain applicants," is added that states that the NRC will not issue a certificate of compliance to the Corporation under these parts if:
(1) It is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; (2) Issuance would be inimical to the connnon defense and security of the United States; or (3) Issuance would be inimical to the maintenance of a reliable and economical domestic source of enrichment services.
Another provision in the legislation eliminates the requirement that the NRC must certify that USEC or its successor's operation of the gaseous diffusion plants is in compliance with NRC regulations each year.
- Instead, the Commission may determine how frequently the USEC or its successor must submit a recertification application to the NRC.
However, NRC must recertify the Corporation's compliance at least every 5 years. The initial certification, granted in a September 19, 1996 Director's decision, was made effective for 2 years to permit most items of USEC's compliance plan to be completed.
As part of the certification ~rocess, the compliance plan details how the Corporation will achieve compliance with NRC regulations in transition from the operation of the gaseous diffusion plants under the requirements of the Department of Energy to operation under the regulatory authority of the NRC.
Subsequent recertification will be based on a number of considerations, including implementation status of compliance plans and certification regulatory experience as determined by the NRC's inspection program.
The exact term of each certification will be specified in the certificate. As noted in a Senate Committee report on a previous version of the legislation 10
{S. Rpt. No. 104-173 on S.755, November 17, 1995, page 31), "With periodic certification, the NRC would have the flexibility to determine the appropriate length of certification, not to exceed five years." Specific implementing amendments are as follows:
10 CFR 76.31 is revised to provide for periodic application for recertification of compliance on or before April 15 of the year specified in an exist i iig -certificate- -of comp 1 i arice -as deteriili nea --by the -co11111i ss ion, but rfot less frequently than every 5 years.
Accordingly, in 10 CFR 76.35, 76.36, 76.43, 76.45, 76.55, and 76.66 references to annual recertification are removed.
10 CFR 76.68 is revised to provide that the Corporation or its successor will continue to submit revised change pages to their approved application and safety analysis report annually to ensure current plant documentation, even
~
though the requirement for an annual application has been removed.
In addition, in response to the "Rulemaking Plan - USEC Privatization
- ~
Act," which was made available to the public on the NRC electronic bulletin board, USEC by letter dated November 13, 1996, provided co111nent concerning the i:
rulemaking action (enclosure 3).
In their letter USEC provided proposed revisions to CFR Parts 76, 70, and 40 for the purposes of implementing the USEC Privatization Act, and proposed language to§ 76.45 to clarify the agency's intention concerning Director's decision on applications for amendments to the Certificate.
USEC also proposed deleting certain sections which in their view are i11111aterial now that the Director's decision on the initial certification has been issued.
With respect to the first item, no new informatiqn was provided beyond that which the staff had already considered in this direct final rulemaking.
The other USEC proposed revisions are not 11
included as a part of this limited scope direct final rulemaking as they are not revisions to the Co11111issioo's regulations which are required by the legislative amendments to the Act being here codified.
The Co1T111ission is proceeding with this rulemaking to amend 10 CFR Parts 2, 40, 70, and 76 as required to implement section 3116 of Pub L. 104-134.
To confonn with these changes to the Act, the amendments in this rule contain several new and revised AVLIS licensing and gaseous diffusion plant certification requirements specific to the Corporation's and its successor's operation of uranium enrichment facilities.
In su11111ary, the amendments to 10 CFR Chapter I are being made to:
{a) Provide that uranium enrichment facilities will be licensed under 10 CFR Part 70, Domestic Licensing of Special Nuclear Material {See§ 70.1);
b) Add and amend where needed the definition of "Corporation" to include the USEC privatized entity (See§§ 40.4, 70.4 and 76.4);
c) Note that the Commission will not issue a license/certificate if the Commission finds that USEC or its successor is under foreign ownership or control or that issuance would be inimical to the co11111on defense and security or to the maintenance of a reliable and economical source of domestic enrichment services (See§§ 40.38, 70.40, and 76.22);
d) Amend the provision concerning periodic recertification for operation (See§§ 76.31, 76.35(n), 76.36{a), 76.43, 76.45(a), 76.55, 76.66 and 76.68(b)); and e) Note and clarify the authority to issue civil penalties to USEC or its successor for regulatory violations (See§§ 2.200(a), 2.205(a), 76.lO(b),
76.60, 76.72{d) and 76.131).
12
The NRC is also amending the regulations in 10 CFR Part 76 to correct several miscellaneous errors in the regulatory text. These errors in the Code of Federal Regulations text occurred in the process of preparing and printing the final rule published on September 23, 1994 (59 FR 48944). Specifically:
in§ 76.2l(b) the reference to§ 40.41 should be to§ 40.51; in§§ 76.111 and 76.113 "uncontrolled classified* should be *unclassified Controlled" Nuclear
- Information, and in § 76.76(a)(2) the "(t)* should be -n-(b)."
In addition; the definition of *uranium enrichment plant" is removed from§ 76.4 because it is neither needed nor used in Part 76, which is specific to gaseous diffusion plants.
Furthermore, the NRC is amending the regulations in 10 CFR Part 2-*.to reflect an agency reorganization. Specifically: in§ 2.205 paragraphs (a),
(d), (g) and (h) all references to the ".Deputy Executive Director for Nuclear Materials Safety, Safeguards, and Operations Support, or the Deputy's designee" are changed to read "Executive Director for Operations or the Executive Director's designee."
Electronic Access Conunents may be submitted electronically, in either ASCII text or WordPerfect format (version 5.1 or later), by calling the NRC Electronic.
Bulletin Board (BBS) on FedWorld.
The Bulletin Board may be accessed using a personal computer, a modem, and one of the co11111only available cOIJlllunications software packages, or directly via Internet. Background documents on the rulemaking are also available, as practical, for downloading and viewing on the Bulletin Board.
13
If using a personal computer and modem, the NRC rulemaking subsystem on FedWorld can be accessed directly by dialing the toll free number (800) 303-9672.
Communication software parameters should be set as follows:
parity to none, data bits to 8, and stop bits to 1 (N,8,1). Using ANSI or VT-100 tenninal emulation, the NRC rulemaking subsystem can then be accessed by selecting the *Rules Menu" option from the "NRC Main Menu."
Users will find the "FedWorld Online User's Guides" particularly helpful.
Many NRC subsystems and data bases also have a *Help/Information Center" option that is tailored to the particular subsystem.
The NRC subsystem on FedWorld can also be accessed by a direct dial phone number for the main FedWorld BBS, (703) 321-3339, or by using Telnet via Internet: fedworld.gov.
If using (703) 321-3339 to contact FedWorld, the NRC subsystem will be accessed from the main FedWorld menu by selecting the "Regulatory, Government Administration and State Systems," then selecting "Regulatory Information Mall." At that point, a menu will be displayed that has an option "U.S. Nuclear Regulatory Conmission" that will take you to the NRC Online main menu.
The NRC Online area also can be accessed directly by typing "/go nrc" at a FedWorld conmand line. If you access NRC from FedWorld's main menu, you may return to FedWorld by selecting the "Return to
-FedWorld" option from the NRC Online Main Menu.
However, if you access NRC at FedWorld by usjng NRC's toll-free number, you will have full access to all NRC systems, but you will not have access to the main FedWorld system.
If you contact FedWorld using Telnet, you will see the NRC area and menus, including the Rules Menu.
Although you will be able to download documents and leave messages, you will not be able to write conments or upload files (conments).
If you contact FedWorld using FTP, all files can be 14
accessed and downloaded but uploads are not allowed; all you will see is a list of files without descriptions (normal Gopher look).
An index file listing all files within a subdirectory, with descriptions, is available.
There is a IS-minute time limit for FTP access.
Although FedWorld also can be accessed through the World Wide Web, like FTP, that mode only provides access for downloading files and does not display the NRC Rules Menu.
For more information on NRC bulletin boards call Mr. Arthur Davis, Systems Integration and Development Branch, NRC, Washington, DC 20555-0001, telephone (301) 415-5780; e-mail AXD3@nrc.gov.
Procedural Background The NRC considers this action noncontroversial and routine because it implements specific statutory requirements {Pub. L. 104-134). Therefore, the Con111ission is approving it without seeking public con111ents on proposed amendments.
This action will become effective on [60 days after publication
~
in the Federal Register]. However, if the NRC receives significant adverse conments by [30 days after publication in the Federal Register], the NRC will withdraw this action and address the significant adverse con111ents received in response to the revisions published in this Federal Register notice before a final rule becomes effective. The NRC will not initiate a second co11111ent period on this action.
15
Revision to NUREG-1600 "General Statement of Policy and Procedures for NRC Enforcement Actions" Concurrently with this Direct Final Rule the Co11111ission is publishing a document elsewhere in this issue of the Federal Register that amends NUREG-1600, "General Statement of Policy and Procedures for NRC Enforcement Action" which provides examples of violations in each of the four severity levels as guidance in determining the appropriate severity level for violations in the areas of fuel cycle and gaseous diffusion plant operations. The amendment is
~
to Supplement VI, "Fuel Cycle and Materials Operations," which provides additional examples of violations that should be categorized at Severity Levels I, II, III, and IV.
In addition, the Enforcement Policy is being amended to establish base civil penalties for GDPs.
The policy recognizes that regulatory requirements have varying degrees of safety, safeguards, or environmental significance. Therefore, the relative importance of each violation, including both the technical significance and the regulatory significance, is evaluated as the first step in the enforcement process.
In considering the significance of a violation, the staff.considers the technical significance (i.e., actual and potential consequences) and regulatory significance.
16
Environmental Impact:
Categorical Exclusion The NRC has detennined that this regulation is the type of action described as a categorical exclusion in 10 CFR 51.22{c)(l) and (3).
Therefore, neither an environmental impact statement nor an environmental assessment has been prepared for this direct final rule.
Paperwork Reduction Act Statement for Direct Final Rule This direct final rule does not contain a new or amended information collection requirement subject to the Paperwork Reduction Act of 1995 {44 U.S.C. 3501 et seq.). Existing requirements were approved by the Office of Management and Budget, approval numbers 3150-0020, -0021, -000~ -0039.
Public Protection Notification The NRC may not conduct or sponsor, and a person is not,required to respond to, a collection of information unless it displays a currently valid 0MB control number.
Regulatory Analysis Changes to 10 CFR Parts 2, 40, 70, and 76 must be made to bring these regulations into confonnance with the Act as amended by the "USEC Privatization Act* (Public Law 104-134).
The chief benefit to the public, industry, and NRC will be derived from codification of NRC regulations to 17
confonn to the changes to the Act.
Codification should result in a better understanding of the procedures and requirements for licensing and/or certification of enrichment facilities, and thereby facilitate the process for review of a license application for uranium enrichment facility, and possibly reduce the litigative risk that might result from not having the regulatory basis for health and safety review of the application codified by regulation.
The principal cost will be the expenditure of NRC staff resources in codifying the requirements.
This constitutes the regulatory analysis for the direct final rule.
Regulatory Flexibility Certification In accordance with the Regulatory Flexibility Act, 5 U.S.C. 605(b), the Commission certifies that this rulemaking will not have a significant economic impact on a substantial number of small entities because it only addresses the Corporation or its successor.
The Corporation does not fall within the scope of the definition of "small entities" set forth in 10 CFR 2.810 or the Small Business Size Standards set out in regulations issued by the Small Business Administration at 13 CFR Part 121.
Small Business Regulatory Enforcement Act In accordance with the Small Business Regulatory Enforcement Fairness Act of 1996, the NRC has determined that this action is not a "major rule" and has verified this determination with the Office of Information and Regulatory Affairs, Office of Management and Budget.
18
Backfit Analysis The NRC has determined that the backfit rules, 10 CFR 50.109 and 76.76, do not apply to this rule. Thus, a backfit analysis is not required for these amendments because they do not involve any provisions that would impose backfits as defined in§§ 50.109(a)(l) and 76.76(a)(l).
List of Subjects 10 CFR Part 2 Administrative practice and procedure, Antitrust, Byproduct materia*l, Classified information, Environmental protection, Nuclear materials, Nuclear power plants and reactors, Penalties, Sex discrimination, Source material, Special nuclear material, Waste treatment and disposal.
10 CFR Part 40 Criminal penalties, Government contracts, Hazardous materials transportation, Nuclear materials, Reporting and recordkeeping requirements, Source material, Uranium.
10 CFR Part 70 Criminal penalties, Hazardous materials transportation, Material control and accounting, Nuclear materials, Packaging and containers, Radiation protection, Reporting and recordkeeping requirements, Scientific equipment, Security measures, Special nuclear material.
19
(
10 CFR Part 76 Certification, Criminal penalties, Radiation protection, Reporting and recordkeeping requirements, Security measures, Special nuclear material, Uranium enrichment by gaseous diffusion.
For the reasons set forth in the preamble and under the authority of the Atomic Energy Act of 1954, as amended; the Energy Reorganization Act of 1974, as amended; and 5 U.S.C. 552 and 553; the Co111T1ission is adopting the following amendments to 10 CFR Parts 2, 40, 70, and 76.
PART 2 -- RULES OF PRACTICE FOR DOMESTIC LICENSING PROCEEDINGS AND ISSUANCE OF ORDERS
- 1. The authority citation for Part 2 is revised to read as f~llows:
AUTHORITY:
Secs. 161, 181, 68 Stat. 948, 953, as amended {42 U.S.C.
2201, 2231); sec. 191, as amended, Pub. L.87-615, 76 Stat. 409 {42 U.S.C.
2241); sec. 201, 88 Stat. 1242, as amended {42 U.S.C. 5841); 5 U.S.C. 552.
Section 2.101 also issued under secs. 53, 62, 63, 81, 103, 104, 105, 68 Stat. 930, 932, 933, 935, 936, 937, 938, as amended {42 U.S.C. 2073, 2092, 2093, 2111, 2133, 2134, 2135); sec. 114{f), Pub. L.97-425, 96 Stat. 2213, as amended {42 U.S.C. 10134{f)); sec. 102, Pub. L.91-190, 83 Stat. 853, as amended (42 U.S.C. 4332); sec. 301, 88 Stat. 1248 {42 U.S.C. 5871). Sections 2.102, 2.103, 2.104, 2.105, 2.721 also issued under secs. 102, 103, 104, 105, 183, 189, 68 Stat. 936, 937, 938, 954, 955, as amended (42 U.S.C. 2132, 2133, 2134, 2135, 2233, 2239).
Section 2.105 also issued under Pub. L.97-415, 96 Stat. 2073 (42 U.S.C. 2239).
Sections 2.200-2.206 also issued under secs.
20
161b, I, o, 182, 186, 234, 68 Stat. 948-951, 955, 83 Stat. 444, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349, as amended (42 U.S.C. 2201 (b),
(I), (o), 2236, 2282); sec. 206, 88 Stat 1246 (42 U.S.C. 5846).
Sections 2.600-2.606 also issued under sec. 102, Pub. L.91-190, 83 Stat. 853, as amended (42 U.S.C. 4332). Sections 2.700a, 2.719 also issued under 5 U.S.C.
554. Sections 2.754, 2.760, 2.770, 2.780 also issued under 5 U.S.C. 557.
Section 2.764 and Table IA of Appendix C also issued under secs. 135, 141, Pub. L.97-425, 96 Stat. 2232, 2241 (42 U.S.C. 10155, 10161). Section 2.790 also issued under sec. 103, 68 Stat. 936, as amended (42 U.S.C. 2133) and 5 U.S.C. 552.
Sections 2.800 and 2.808 also issued under 5 U.S.C. 553. Section 2.809 also issued under 5 U.S.C. 553 and sec. 29, Pub. L.85-256, 71 Stat.
579, as amended (42 U.S.C. 2039). Subpart K also issued under sec. 189, 68 Stat. 955 (42 U.S.C. 2239); sec. 134, Pub. L.97-425, 96 Stat. 2230 (42 U.S.C. 10154). Subpart L also issued under sec. 189, 68 Stat. 955 (42 U.S.C.
2239).
Appendix A also issued under sec. 6, Pub. L.91-560, 84 Stat. 1473 (42 U.S.C. 2135). Appendix B also issued under sec. 10, Pub. L.99-240, 99 Stat.
1842 (42 U.S.C. 2021b et seq.) *
- 2.
In§ 2.200, paragraph (a) is revised to read as follows:
§ 2.200 Scope of subpart.
(a) This subpart prescribes the procedures in cases initiated by the staff, or upon a request by any person, to impose requirements by order, or to modify, suspend, or revoke a license, or to take other action as may be proper, against any person subject to the jurisdiction of the Connn1ssion.
However, with regard to the holder of a Part 76 certificate of compliance or 21
compliance plan, except for civil penalty procedures in this subpart, the applicable procedures are set forth in§ 76.70.
- 3. In§ 2.205, paragraphs (a}, (d}, (g} and (h} are revised to read as follows:
§ 2.205 Civil penalties.
(a}
Before instituting any proceeding to impose a civil penalty under section 234 of the Act, the Executive Director for Operations or the Executive Director's designee, as appropriate, shall serve a written notice of violation upon the person charged. This notice may be included in a notice issued pursuant to§ 2.201 or§ 76.70(d}.
The notice of violation shall specify the date or dates, facts, and the nature of the alleged act or omission with which the person is charged, and shall identify specifically the particular provision or provisions of the law, rule, regulation, license, pennit, Part 76 certificate of compliance or compliance plan, or cease and desist order involved in the alleged violation and must state the amount of each proposed penalty. The notice of violation shall also advise the person charged that the civil penalty may be paid in the amount specified therein, or the proposed imposition of the civil penalty may be protested in its entirety or in part, by a written answer, either denying the violation or showing extenuating circumstances.
The notice of violation shall advise the person charged that upon failure to pay a civil penalty subsequently determined by the Conunission, tf any~ unless compromised, remitted, or mitigated, be collected by civil action, pursuant to Section 234c of the Act.
22
(d} If the person charged with violation files an answer to the notice of violation, the Executive Director for Operations or the Executive Director's designee, upon consideration of the answer, will issue an order dismissing the proceeding or imposing, mitigating, or remitting the civil penalty.
The person charged may, within twenty {20} days of the date of the order or other time specified in the order, request a hearing.
(g) The Executive Director for Operations or the Executive Director's designee, as appropriate may compromise any civil penalty, subject to the provisions of§ 2.203.
(h) If the civil penalty is not compromised, or is not remitted by* the Executive Director for Operations or the Executive Director's designee, as appropriate, the presiding officer, or the Commission, and if payment is not made within ten (10) days following either the service_ of the order described in paragraph (c) or (f) of this section, or the expiration of the time for requesting a hearing described in paragraph {d) of this section, the Executive 23
Director for Operations or the Executive Director's designee, as appropriate, may refer the matter to the Attorney General for collection.
PART 40 -- DOMESTIC LICENSING OF SOURCE MATERIAL
- 4.
The authority citation for Part 40 is revised to read as follows:
AUTHORITY:
Secs. 62, 63, 64, 65, 81, 161, 182, 183, 186, 68 Stat. 932, 933, 935, 948, 953, 954, 955, as amended, secs. lle(2), 83, 84, Pub. L.95-604, 9l Stat. 3033, as amended, 3039, sec. 234, 83 Stat. 444, as amended (42 u.s.c. 2014(e){2), 2092, 2093, 2094, 2095, 2111, 2113, 2114, 2201, 2232, 2233, 2236, 2282); sec. 274, Pub. L.86-373, 73 Stat. 688 (42 U.S.C. 2021); secs. 201, as amended, 202, 206, 88 Stat. 1242, as amended, 1244, 1246 {42 U.S.C.
5841, 5842, 5846); sec. 275, 92 Stat. 3021, as amended by Pub. L.97-415, 96 Stat. 2067 {42 U.S.C. 2022); sec. 193, 104 Stat. 2835, as amended by Pub. L.
104-134, 110 Stat. 1321, 1321-349 (42 U.S.C. 2243).
Section 40.7 also issued under Pub. L.95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851). Section 40.3l(g) also issued under sec. 122, 68 Stat. 939 (42 U.S.C. 2152). Section 40.46 also issued under sec. 184, 68 Stat. 954, as amended (42 U.S.C. 2234). Section 40.71 also issued under sec. 187, 68 Stat.
955 (42 u.s.c. 2237).
- 5.
In§ 40.4, the term "Corporation" is added to read as follows:
§ 40.4 Definitions.
24
Corporation means the United States Enrichment Corporation (USEC), or its successor, a Corporation that is authorized by statute to lease the gaseous diffusion enrichment plants in Paducah, Kentucky, and Piketon, Ohio, from the Department of Energy, or any person authorized to operate one or both of the gaseous diffusion plants, or other facilities, pursuant to a plan for the privatization of USEC that is approved by the President.
- 6.
A new§ 40.38 is added to read as follows:
§ 40.38 Ineligibility of certain applicants.
A license may not be issued to the Corporation if the Commission determines that:
(a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a license would be inimical to-(1) The common defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services.
PART 70 -- DOMESTIC LICENSING OF SPECIAL NUCLEAR MATERIAL
- 7.
The authority citation for Part 70 is revised to read as follows:
AUTHORITY:
Secs. 51, 53, 161, 182, 183, 68 Stat. 929, 930, 948, 953, 954, as amended, sec. 234, 83 Stat. 444, as amended (42 U.S.C. 2071, 2073, 2201, 2232, 2233, 2282, 2297f); secs. 201, as amended, 202, 204, 206, 88 Stat.
25
1242, as amended, 1244, 1245, 1246 (42 U.S.C. 5841, 5842, 5845, 5846); sec. 193, 104 Stat. 2835 as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 (42 u.s.c. 2243).
Sections 70.l and 70.20a(b) also issued under secs. 135, 141, Pub. L.97-425, 96 Stat. 2232, 2241 (42 U.S.C. 10155, 10161). Section 70.7 also issued under Pub. L.95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851). Section 70.21(g) also issued under sec. 122, 68 Stat. 939 (42 U.S.C. 2152). Section 70.31 also issued under sec. 57d, Pub. L.93-377, 88 Stat. 475 (42 U.S.C.
2077).
Sections 70.36 and 70.44 also issued under sec. 184, 68 Stat. 954, as amended (42 U.S.C. 2234). Section 70.61 also issued under secs. 186, 187, 68 Stat. 955 (42 U.S.C. 2236, 2237). Section 70.62 also issued under sec. 108, 68 Stat. 939, as amended (42 U.S.C. 2138).
- 8. In§ 70.1, A new paragraph {e) is added to read as follows:
§ 70.1 Purpose.
(e) As provided in the Atomic Energy Act of 1954, as amended, the regulations in this part establish requirements, procedures, and criteria for the issuance of licenses to uranium enrichment facilities.
- 9. In§ 70.4, the term "Corporation" is added to read as follows:
§ 70.4 Definitions.
26
Corporation means the United States Enrichment Corporation (USEC), or its successor, a Corporation that is authorized by statute to lease the gaseous diffusion enrichment plants in Paducah, Kentucky, and piketon, Ohio, from the Department of Energy, or any person authorized to operate one or both of the gaseous diffusion plants, or other facilities, pursuant to a plan for the privatization of USEC that is approved by the President.
- 10. A new§ 70.40 is added to read as follows:
§ 70.40 Ineligibility of certain applicants.
A license may not be issued to the Corporation if the Commission determines that:
(a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a license would be inimical to-(1) The convnon defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services.
PART 76 -- CERTIFICATION OF GASEOUS DIFFUSION PLANTS
- 11.
The authority citation for Part 76 is revised to read as follows:
AUTHORITY:
Secs. 161, 68 Stat. 948, as amended, secs. 1312, 1701, as amended, 106 Stat. 2932, 2951, 2952, 2953, 110 Stat. 1321-349, (42 U.S.C.
2201, 2297b-ll, 2297f); secs. 201, as amended, 204, 206, 88 Stat. 1244, 1245, 27
1246 {42 U.S.C. 5841, 5842, 5845, 5846); sec. 234{a), 83 Stat. 444, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 {42 U.S.C. 2243{a)).
Sec. 76.7 also issued under Pub. L.95-601, sec. 10, 92 Stat. 2951 {42 U.S.C. 5851). Sec. 76.22 is also issued under sec. 193{f), as amended, 104 Stat. 2835, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 {42 U.S.C.
2243{f)). Sec. 76.35{j) also issued under sec. 122, 68 Stat. 939 {42 ~.S.C.
2152).
- 12. In§ 76.4, the term "Corporation" is amended to read as follows and the term "Uranium enrichment plant" is removed:
§ 76.4 Definitions.
Corporation means the United States Enrichment Corporation {USEC), or
. its successor, a Corporation that is authorized by statute to lease the gaseous diffusion enrichment plants in Paducah, Kentucky, and Piketon,,Ohio, from the Department of Energy, or any person authorized to operate one or both of the gaseous diffusio~ plants, or other facilities, pursuant to a plan for the pri vat i zat i o.n of USEC that is approved by the President.
- 13.
In§ 76.10, paragraph {b) is revised to read as follows:
§ 76.10 Deliberate misconduct.
28
(b) A person who violates paragraph (a)(l) or (a)(2) of this section may be subject to enforcement action in accordance with the procedures in 10 CFR Part 2, subpart B.
- 14.
In§ 76.21, paragraph (b) is revised to read as follows:
§ 76.21 Certificate required.
(b)
For the purposes of§§ 30.41, 40.51, and 70.42 of this chapter, the Corporation shall be authorized to receive, and licensees shall be authorized to transfer to the Corporation, byproduct material, source material, or special nuclear material to the extent pennitted under the certificate of compliance issued, and/or the compliance plan approved, pursuant to this part.
- 15.
A new§ 76.22 is added to read as follows:
§ 76.22 Ineligibility of certain applicants.
A certificate of compliance may not be issued to the Corporation if the Commission detennines that:
(a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a certificate of compliance would be inimical to-(1) The conunon defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services. -
29
- 16. Section 76.31 is revised to read as follows:
§ 76.31 Periodic application requirement.
The Corporation shall periodically apply to the Convnission for a certificate of compliance, in accordance with§ 76.36, on or before April 15 of the year specified in an existing certificate of compliance as determined by the Commission, but not less frequently than every 5 years.
- 17.
In§ 76.35, paragraph (n) is revised to read as follows:
§ 76.35 Contents of initial application.
(n) A description of the funding program to be established to ensure that funds will be set aside and available for those aspects of the ultimate disposal of waste and depleted uranium, decontamination and deconmissioning, relating to the gaseous diffusion plants leased to the Corporation by the Department of Energy, which are the financial responsibility of the Corporation.
The Corporation shall establish financial surety arrangements to ensure that sufficient funds will be available for the ultimate disposal of waste and depleted uranium, and decontamination and decommissioning activities which are the financial responsibility of the_Corporation.
The funding mechanism, such as prepayment, surety, insurance, or e~ternal sinking fund, must ensure availability of funds for any activities which are required to be completed both before or after the return of the gaseous diffusion facilities to the Department of Energy in accordance with the lease between the Department and the Corporation.
The funding program must contain a basis for cost estimates used to establish funding levels and must contain means of adjusting cost estimates and associated funding levels over the duration of 30
the lease. The funding program need not address funding for those aspects of decontamination and deco111111ss1on1ng of the gaseous diffusion plants assigned to the Department of Energy under the Atomic Energy Act of 1954, as amended.
The Corporation should address the adequacy of the financing mechanism selected in its periodic application for certification.
- 18. In§ 76.36, the section heading and paragraph (a) are revised to read as follows:
§ 76.36 Renewals.
(a) After issuance by the Commission of the initial certificate of compliance and/or an approved compliance plan, the Corporation shall file periodic applications for renewal, as required by§ 76.31.
- 19. Section 76.43 is revised to read as follows:
§ 76.43 Date for decision.
The Director will render a decision on an application within 6 months of the receipt of the application unless the Director alters the date for decision and publishes notice of the new date in the Federal Regiiter.
- 20.
In§ 76.45, paragraph (a) is revised to read as follows:
§ 76.45 Application for amendment of certificate.
(a) Contents of amendment application.
In addition to the application for certification subm'itted pursuant to § 76.31, the Corporation may at any time apply for amendment of the certificate to cover proposed new or modified activities. The amendment application should contain sufficient information 31
for the Director to make findings of compliance or acceptability for the proposed activities as required for the original certificate.
- 21. Section 76.55 is revised to read as follows:
§ 76.55 Timely renewal.
In any case in which the Corporation has timely filed a sufficient application for a certificate of compliance, the existing certificate of compliance or approved compliance plan does not expire until the application for a certificate of compliance has been finally determined by the NRC.
For purposes of this rule, a sufficient application is one that addresses all elements of§ 76.36.
- 22.
In§ 76.60, paragraphs (c)(l), and (d)(l), are removed and reserved and paragraph (i) is revised to read as follows:
§ 76.60 Regulatory requirements which apply.
(c)
(1)
[Reserved]
(d)
(1)
[Reserved]
32
(i) The Corporation shall comply with the applicable provisions of IO CFR Part 95, "Security Facility Approval and Safeguarding of National Security Information and Restricted Data, 8 as specified in subpart E to this part.
- 23.
In§ 76.66, paragraph {c) is revised to read as follows:
§ 76.66 Expiration and termination of certificates.
{c) If the Corporation does not submit a renewal application under
§ 76.36, the Corporation shall, on or before the expiration date specified in the existing certificate, terminate operation of the gaseous diffusion plants.
- 24.
In§ 76.68, paragraph {b) is revised to read as follows:
§ 76.68 Plant changes.
{b) To ensure that the approved application rema~ns current with respect to the actual site description and that the plant's programs, plans, policies, and operations are in place, the Corporation shall submit revised pages to the approved application and safety analysis report, marked and dated to indicate each change.
The Corporation shall evaluate any as-found conditions that do not agree with the plant's programs, plans, policies, and operations in accordance with paragraph {a) of this section. These revisions must be 33
submitted before April 15 of each calendar year, or at a shorter interval as may be specified in the certificate. If a renewal application for a certificate is filed in accordance with§ 76.36 of this part, the revisions shall be incorporated into the application.
- 25.
In§ 76.72, paragraph (d} is revised to read as follows:
§ 76.72 Miscellaneous procedural matters.
(d} The procedures set forth in 10 CFR 2.205, and in 10 CFR Part 2, subpart G, will be applied in connection with NRC action to impose a civil penalty pursuant to Section 234 of the Atomic Energy Act of 1954, as amended, or Section 206 of the Energy Reorganization Act of 1974 and the implementing regulations in 10 CFR Part 21 (Reporting of Defects and Noncompliance}, as authorized by Section 1312(e} of the Atomic Energy Act of 1954, as amended;
- 26.
In§ 76.76, paragraph (a}(2} is revised to read as follows:
§ 76.76 Backfitting.
(a}
(2} Except as provided in paragraph (a}(4} of this section, the Commission shall require a systematic and documented analysis pursuant to paragraph (b} of this section for backfits which it seeks to impose.
34
- 27.
Section 76.111 is revised to read as follows:
§ 76.111 Physical security, material control and accounting, and protection of certain information.
Nuclear Regulatory CoD111ission regulations that will be used for certification of the Corporation1 for physical security and material control and accounting are contained in Title 10 of the Code of Federal Regulations as described in this subpart.
The regulations referenced in this subpart contain requirements for physical security and material control and accounting for formula quantities of strategic special nuclear material {Category I), special nuclear material of moderate strategic significance {Category II), and special nuclear material of low strategic significance {Category Ill), and for protection of Restricted Data, National Security Information, Safeguards Information, and information designated by the U.S. Department of Energy as Unclassified Controlled Nuclear Information.
- 28.
In§ 76.113, paragraph {c) is revised to read as follows:
§ 76.113 Formula quantities of strategic special nuclear material-Category I.
1For the purpose of this subpart, the terms *licensee" or "license" used in parts 70, 73, and 74 of this chapter, mean, respectively, the Corporation, or the certificate of compliance or approved compliance plan.
35
(c) The requirements for the protection of Safeguards Information pertaining to formula quantity of strategic special nuclear material (Category I) are contained in§ 73.21.
Information designated by the U.S.
Department of Energy as Unclassified Controlled Nuclear Information must be protected at a level equivalent to that accorded Safeguards Information.
- 29. Section 76.131 is revised to read as follows:
§ 76.131 Violations.
(a) The Commission may obtain an injunction or other court order to prevent a violation of the provisions of:
(1} The Atomic Energy Act of 1954, as amended;
{2) Title II of the Energy Reorganization Act of 1974, as amended; (3} A regulation or order issued pursuant to those Acts.
(b) The Commission may obtain a court order for the payment of a civil penalty imposed under Section 234 of the Atomic Energy Act of 1954, as amended, or under Section 1312(e) of the Atomic Energy Act of 1954, as amended, and Section 206 of the Energy Reorganization Act of 1974, as amended, for violations of:
(1) Sections 53, 57, 62, 63, 81, 82, 101, 103, 104, 107, 109, or 1701 of the Atomic Energy Act of 1954, as amended; (2)
Section 206 of the Energy Reorganization Act; (3) Any rule, regulation, or order issued pursuant to the sections specified in paragraph {b)(l) of this section; 36
(4}
Any term, condition, or limitation of any certificate of compliance or approved compliance plan issued under the sections specified in paragraph (b}(l} of this section.
Dated at Rockville, Maryland, this C, -t!:: day of February, 1997.
For the Nuclear Regulatory Commission.
John
- Hoyle, Seer ary of the Commission.
37
NUCLEAR REGULATORY COMMISSION 10 CFR Parts 2, 40, 70, and 76 RIN: 3150-AFS6 USEC Privatization Act DOCKETED USHRC
[7590-01-P]
"9? f£8 l O A10 :54 OFFICE OF SEC ETARY DOCKETING & SERVICE RANCH AGENCY:
Nuclear Regulatory Commission.
DOCKET NUMBER ACTION:
Proposed rule.
PROPOSED RULE PB ~ -t-10,, 1 O I J /p
( (p~ Ff<. t,~7~)
SUMMARY
The Nuclear Regul atory Commission (NRC) is proposing to amend its regulations concerning the certification and licensing of uranium enrichment facilities to conform to changes made to the Atomic Energy Act of 1954, as amended (the Act), by the USEC Privatization Act legislation. Although the principal effect of this legislation is to direct the Board of Directors of the United States Enrichment Corporation (USEC) to sell the assets of the USEC to a private sector entity, this legislation also amended the Act with respect to NRC certification of gaseous diffusion plants leased by USEC and the licensing of atomic vapor laser isotope separation (AVLIS) technology.
USEC is responsible for the operation of the two gaseous diffusion plants and the development of the AVLIS technology.
The legislation requires that AVLIS uranium enrichment facilities be licensed subject to the provisions of the Act pertaining to source material and special nuclear material rather than under the provisions pertaining to a production facility; provides for the issuance of civil penalties to USEC or its successor for failure to comply with regulatory requirements governing the operation of gaseous diffusion plants; prohibits issuance of a license/certificate to the Corporation or its successor if it is owned,
controlled, or dominated by an alien, a foreign corporation, or a foreign government, or its issuance would be inimical to the common defense and security of the United States or to the maintenance of a reliable and economical domestic source of enrichment services; and eliminates the annual requirement that the Commi ssion certify that USEC or its successor is in compliance with NRC regulations.
The Commission may determine how frequently USEC or its successor must submit a recertification application to the NRC, provided that the NRC recertify USEC's or its successor's compliance with its regulations not less frequently than every five years.
The proposed changes to the regulations bring 10 CFR Parts 2, 40, 70, and 76 into conformance with the USEC Privatization Act.
DATE:
Comments on the proposed rule must be received on or before [insert date 30 days after publication in the Federal Register].
~
11; !99'1 ADDRESSES:
Mail written comments to: The Secretary, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.
ATTN:
Docketing and Service Branch.
Hand deliver comments to:
11555 Rockville Pike, Rockville, MD, between 7:30 am and 4:15 pm on Federal workdays.
For information on submitting comments electronically, see the discussion under Electric Assess in the Supplementary Information Section.
Copies of comments received may be examined or copied for a fee, at the NRC Public Document Room, 2120 L Street NW. (Lower Level), Washington, DC.
2
j.
NUCLEAR REGULATORY CotttISSION 10 CFR Parts 2, 40, 70, and 76 RIN: 3150-AF56 USEC Privatization Act DOCKETED USHRC
[7590-01-P]
"91 f£B \0 A10 :54 ib~~f8~GsiCf f Jt,~t eRAHCH AGENCY:
Nuclear Regulatory Commission.
DOCKET.NUMBERM ACTION:
Proposed rule.
PROPOSED RULE re ~--;-40, 10 17b
({r;~Ff?.t,t,J:i.)
SUMMARY
The Nuclear Regulatory Commission (NRC) is proposing to amend its regulations concernifig the certification and licensing of uranium enrichment facilities to conform to changes made to the Atomic Energy Act of 1954, as*
amended (the Act), by the USEC Privatization Act legislation. Although the principal effect of this legislation is to direct the Board of Directors of*
the United States Enrichment Corporation (USEC) to sell the assets of the USEC to a ~rivate sector entity, this legislation also amended the Act with respect to NRC certification of gaseous diffusion plants leased by USEC and the l'icensing of atomic vapor laser isotope separation (AVLIS) technology.
USEC is responsible for the operation of the two gaseous diffusion plants and the development of the AVLIS technology.
The legislation requires that AVLIS uranium enrichment facilities be licensed subject to the provisions of the Act pertaining to source material and special nuclear material rather than under the provisions pertaining to a production facility; provides for the issuance of civil penalties to USEC or its successor for failure to comply with regulatory requirements governing the operation of gaseous diffusion plants; prohibits issuance of a license/certificate to the Corporation or its successor if it is owned,
controlled, or dominated by an alien, a foreign corporation, or a foreign government," or its fssuance would be inimical to the common defense and security. of the United States or to the maintenance of a reliable and
~
economical ~omestic<source of enrichment services; and eliminates the annual requirement that the Commission certify that USEC or its. successor is in compliance with NRC regulations.
The Commission may determine how frequently USEC or its successor must submit a recertification application to the NRC, prov'ide'd**that the NRC recertify USEC's or its successor's compliance with its regulations not less frequently than every five years. The proposed changes to the regulations bring 10 CFR Parts 2, 40, 70, and 76 into conformance with the USEC Privatization Act.
DATE:
Comments on the proposed.rule must be received on or before [insert date 30 days after publication in the Federal Register].
~
t'f; /C/9'1 ADDRESSES:
Mail written comments to: The Secretary, U.S. Nuclear Regulatory Corrmission, Washington, DC *20555-0001.
ATTN:
Docketing and Service Branch.
Hand deliver comments to:
11555 Rockville Pike, Rockville, MD, between 7:30 am and 4:15 pm on Federal workdays.
For information on submitting commen~s electronically, see the discussion under Electric Assess in the Supplementary Information Section.
. Copies of comments received may be examined or copied for a fee, at the NRC Public Document Room, 2120 L Street NW. (Lower Level), Washington, DC.
2
FOR FURTHER INFORMATION CONTACT:
Mr. C. W. Nilsen, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Co1T1T1ission, Washington, DC 20555-0001, telephone (301) 415-6209.
SUPPLEMENTARY INFORMATION:
F.or-add-iti-onal -information see the Direct Final Rule published in the rules section of this Federal Register.
Procedural Background The NRC considers this action noncontroversial and routine because it implements specific statutory requirements (Public Law 104-134). Therefore, we are publishing this proposed rule concurrently as a Oirect Final Rule in the final rule section of this Federal Register.
The Direct Final Rule will become effective on [insert 60 days after publication in the Federal Register].
However, if the NRC receives significant adverse co1T1T1ents by {30 days after publication in the Federal Register), the NRC will withdraw the Direct Final Rule and address the significant adverse conunents received in response to the revisions.
Any significant adverse connents will be addressed in a subsequent final rule on this proposal. Absent significant modifications to the propo.sed revisions requiring repub l i cation, the NRC wi 11 not initiate a second comment period on this action.
3
Electronic Access Conments may be submitted electronically, in either ASCII text or WordPerfect fonnat {version 5.1 or later), by calling the NRC Electronic Bulletin Board {BBS) on FedWorld.
The Bulletin Board may be accessed using a personal computer, a modem, and one of the convnonly available co111T1unications software packages, or directly via Internet. Background documents on the rulemaking are also available, as practical, for downloading and viewing on the Bulletin Board.
If using a personal computer and modem, the NRC rulemaking subsystem on FedWorld can be accessed directly by dialing the toll free number {800) 303-9672.
Co1T111unication software parameters should be set as follows:
parity to none, data bits to 8, and stop bits to 1 {N,8,1). Using ANSI or VT-100 terminal emulation, the NRC rulemaking subsystem can then be accessed by selecting the "Rules *Menu" option from the "NRC Main Menu."
Users will find the "FedWorld Online User's Guides" particularly helpful.
Many NRC subsystems and data bases also have a "Help/Information Center* option that is tailored to the particular subsystem.
The NRC subsystem on FedWorld can also be accessed by a direct dial phone number for the main FedWorld BBS, {703) 321-3339, or by using Telnet via Internet: fedworld.gov.
If using (703) 321-3339 to contact FedWorld, the NRC subsystem will be accessed from the main FedWorld menu by selecting the "Regulatory, Government Administration and State Systems," then selecting
- Regulatory Information Mall.* At that point, a menu will be displayed that has an option "U.S. Nuclear Regulatory Collll'li~sion" that will take you to the NRC Online main menu.
The NRC Online area also can be accessed directly by 4
typing "/go nrc 11 at a FedWorld command line. If you access NRC from FedWorld's main menu, you may return to FedWorld by selecting the "Return to FedWorld 11 option from the NRC Online Main Menu.
However, if you access NRC at FedWorld by using NRC's toll-free number, you will have full access to all NRC systems, but you will not have access to the main FedWorld system.
If you contact FedWorld using Telnet, you will see the NRC area and menus, including the Rules Menu.
Although you will be able to download documents and leave messages, you will not be able to write comments or upload files {comments).
If you contact FedWorld using FTP, all files can be accessed and downloaded but uploads are not allowed; all you will see is a list of files without descriptions {normal Gopher 1 ook).
An index f1 le -
listing all files within a subdirectory, with descriptions, is available:
There is a IS-minute time limit for FTP access.
Although FedWorld also can be accessed through the World Wide Web, like FTP, that mode only provides access for downloading files and does not display the NRC Rules Menu.
For more information on NRC bulletin boards call Mr. Arthur Davis,':-
Systems Integration and Development Branch, NRC, Washington, DC 20555-0001, telephone {301) 415-5780; e-mail AXD3~nrc.gov.
List of Subjects 10 CFR Part 2 Administrative practice and procedure, -Antitrust, Byproduct material, Classified infonnation, Environmental protection, Nuclear materials, Nuclear 5
power plants and reactors, Penalties, Sex discrimination, Source material, Special nuclear material, Waste treatment and disposal.
10 CFR Part 40 Criminal penalties, Government contracts, Hazardous materials transportation, Nuclear materials, Reporting and recordkeeping requirements, Source material, Uranium.
10 CFR Part 70 Criminal penalties, Hazardous materials transportation, Material control and accounting, Nuclear materials, Packaging and containers, Radiation protection, Reporting and recordkeeping requirements, Scientific equipment, Security measures, Special nuclear material.
10 CFR Part 76 Certification, Criminal penalties, Radiation protection, Reporting and recordkeeping requirements, Security measures, Special nuclear material, Uranium enrichment by gaseous diffusion.
For the reasons set forth in the preamble and under the authority of the Atomic Energy Act of 1954, as amended; the Energy Reorganization Act of 1974, as amended; and 5 U.S.C. 552 and 553; the Convnission is adopting the following amendments to 10 CFR Parts 2, 40, 70, and 76.
6
/
PART 2 -- RULES OF PRACTICE FOR DOMESTIC LICENSING PROCEEDINGS AND ISSUANCE OF ORDERS
- 1.
The authority citation for Part 2 is revised to read as follows:
AUTHORITY:
Secs. 161, 181, 68 Stat. 948, 953, as amended (42 U.S.C.
2201, 2231}; sec. 191, as amended, Pub. L.87-615, 76 Stat. 409 (42 U.S.C.
2241}; sec. -201, 88 Stat. -1242; as amended (4-2 U.S.C. 5841}; 5-U.S.C. -552. -
Section 2.101 also issued under secs. 53, 62, 63, 81, 103, 104, 105, 68 Stat. 930, 932, 933, 935, 936, 937, 938, as amended (42 U.S.C. 2073, 2092, 2093, 2111, 2133, 2134, 2135}; sec. 114(f}, Pub. L.97-425, 96 Stat. 2213, as amended (42 U.S.C. 10134(f; sec. 102, Pub. L. 91-190, 83 Stat. 853, as~ amended (42 U.S.C. 4332}; sec. 301, 88 Stat. 1248 (42 U.S.C. 5871}. Sections 2.102, 2.103, 2.104, 2.105, 2.721 also tssued under secs. 102, 103, 104, 105, 183, 189, 68 Stat. 936, 937, 938, 954, 955, as amended (42 U.S.C. 2132, 2133, 2134, 2135, 2233, 2239}. Section 2.105 also issued under Pub. L. 97-415, 96 Stat. 2073 (42 U.S.C. 2239}. Sections 2.200-2.206 also issued under secs. 161b, I, o, 182, 186, 234, 68 Stat. 948-951, 955, 83 Stat. 444, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349, as amended (42 U.S.C. 2201 (b}, (I}, (o), 2236, 2282); sec. 206, 88 Stat 1246 (42 U.S.C. 5846}. Sections 2.600-2.606 also issued under sec. 102, Pub. L. 91-190, 83 Stat. 853, as amended (42 U.S.C. 4332}. Sections 2.700a, 2.719 also issued under 5 U.S.C. 554. Sections 2.754, 2.760, 2.770, 2.780 also issued under 5 U.S.C. 557. Section 2.764 and Table IA of Appendix C also issued under secs. 135, 141, Pub. L. 97-425, 96 Stat. 2232, 2241 (42 U.S.C. 10155, 10161}. Section 2.790 also issued under sec. 103, 68 Stat. 936, as amended (42 U.S.C. 2133) and 5 U.S.C. 552. Sections 2.800 and 2.808 also issued under 5 U.S.C. 553. Section 7
2.809 also issued under 5 U.S.C. 553 and sec. 29, Pub. L. 85-256, 71 Stat. 579, as amended {42 U.S.C. 2039). Subpart K also issued under sec. 189, 68 Stat. 955 {42 U.S.C. 2239); sec. 134, Pub. L. 97-425, 96 Stat. 2230 {42 U.S.C. 10154). Subpart L also issued under sec. 189, 68 Stat. 955 {42 U.S.C. 2239). Appendix A also issued under sec. 6, Pub. L. 91-560, 84 Stat. 1473 {42 U.S.C. 2135). Appendix B also issued under sec. 10, Pub. L. 99-240, 99 Stat. 1842 {42 U.S.C. 2021b et seq.).
- 2.
In§ 2.200, paragraph {a) is revised to read as follows: § 2.200 Scope of subpart. {a) This subpart prescribes the procedures in,cases initiated by the staff, or upon a request by any person, to impose requirements by order, or to modify, suspend, or revoke a license, or to take other action as may be proper, against any person subject to the jurisdiction of the Convnission. However, with regard to the holder of a Part 76 certificate of compliance or compliance plan, except for civil penalty procedures in this subpart, the applicable procedures are set forth in§ 76.70.
- 3. In§ 2.205, paragraphs {a), {d), {g) and {h) are revised to read as follows:
§ 2.205 Civil penalties. {a) Before instituting any proceeding to impose a civil penalty under section 234 of the Act, the Executive Director for Operations or the Executive Director's designee, as appropriate, shall serve a written notice of violation 8
upon the person charged. This notice may be included in a notice issued pursuant to§ 2.201 or§ 76.70(d}. The notice of violation shall specify the date or dates, facts, and the nature of the alleged act or omission with which the person is charged, and shall identify specifically the particular provision or provisions of the law, rule, regulation, license, permit, Part 76 certificate of compliance or compliance plan, or cease and desist order involved in the alleged violation and must state the amount of each proposed penalty. The notice of violation shall also advise the person charged that the civil penalty may be paid in the amount specified therein, or the proposed imposition of the civil penalty may be protested in its entirety or in part, by a written answer, either denying the violation or showing extenuating__,: circumstances. The notice of violation shall advise the person charged that upon failure to pay a civil penalty subsequently determined by the Convnission, if any, unless compromised, remitted, or mitigated, be collected by civil action, pursuant to section 234c of the Act. (d) If the person charged with violation files an answer to the notice of violation, the Executive Director for Operations or the Executive Director's designee, upon consideration of the answer, will issue an order dismissing the proceeding or imposing, mitigating, or remitting the civil penalty. The person charged may, within twenty (20} days of the date of the order or other time specified in the order, request a hearing. 9
{g) The Executive Director for Operations or the Executive Director's designee, as appropriate may compromise any civil penalty, subject to the provisions of§ 2.203. {h) If the civil penalty is not compromised, or is not remitted by the Executive Director for Operations or the Executive Director's designee, as appropriate, the presiding officer, or the Commission, and if payment is not made within ten (10) days following either the service of the order described in paragraph {c) or (f) of this section, or the expiration of the time for requesting a hearing described in paragraph {d) of this section, the Executive Director for Operations or the Executive Director's designee, as appropriate, may refer the matter to the Attorney General for collection. PART 40 -- DOMESTIC LICENSING OF SOURCE MATERIAL
- 4.
The authority citation for Part 40 is revised to read as follows: AUTHORITY: Secs. 62, 63, 64, 65, 81, 161, 182, 183, 186, 68 Stat. 932, 933, 935, 948, 953, 954, 955, as amended, secs. lle(2), 83, 84, Pub. L. 95-604, 92 Stat. 3033, as amended, 3039, sec. 234, 83 Stat. 444, as amended (42 U.S.C. 2014{e)(2), 2092, 2093, 2094, 2095, 2111, 2113, 2114, 2201, 2232, 2233, 10
2236, 2282); sec. 274, Pub. L. 86-373, 73 Stat. 688 (42 U.S.C. 2021); secs. 201, as amended, 202, 206, 88 Stat. 1242, as amended, 1244, 1246 (42 U.S.C. 5841, 5842, 5846); sec. 275, 92 Stat. 3021, as amended by Pub. L. 97-415, 96 Stat. 2067 (42 U.S.C. 2022); sec. 193, 104 Stat. 2835, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 (42 U.S.C. 2243). Section 40.7 also issued under Pub. L. 95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851). Section 40.3l(g) also issued under sec. 122, 68 Stat. 939 (42 U.S.C. 2152). Section 40.46 also issued under sec. 184, 68 Stat. 954, as amended (42 U.S.C. 2234). Section 40.71 also issued under sec. 187, 68 Stat. 955 (42 u.s.c. 2237).
- 5.
In§ 40.4, the tenn "Corporation" is added to read as follows: § 40.4 De'finitions. Corporation means the United States Enrichment Corporation (USEC), or its successor, a Corporation that is authorized by statute to lease the gaseous diffusion enrichment plants in Paducah, Kentucky, and Piketon, Ohio, from the Department of Energy, or any person authorized to operate one or both of the gaseous diffusion plants, or other facilities, pursuant to a plan for the privatization of USEC that is approved by the President.
- 6. A new§ 40.38 is added to read as follows:
§ 40.38 Ineligibility of certain applicants. 11
A license may not be issued to the Corporation if the Commission determines that: (a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a license would be inimical to-(1) The conman defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services. PART 70 -- DOMESTIC LICENSING OF SPECIAL NUCLEAR MATERIAL
- 7.
The authority citation for Part 70 is revised to read as follows: AUTHORITY: Secs. 51, 53, 161, 182, 183, 68 Stat. 929, 930, 948, 953, 954, as amended, sec. 234, 83 Stat. 444, as amended (42 U.S.C. 2071, 2073, 2201, 2232, 2233, 2282, 2297f); secs. 201, as amended, 202, 204, 206, 88 Stat. 1242, as amended, 1244, 1245, 1246 (42 U.S.C. 5841, 5842, 5845, 5846); sec. 193, 104 Stat. 2835 as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 (42 u.s.c. 2243). Sections 70.l and 70.20a(b) also issued under secs. 135, 141, Pub. L. 97-425, 96 Stat. 2232, 2241 (42 U.S.C. 10155, 10161). Section 70.7 also issued under Pub. L. 95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851). Section 70.21(g) also issued under sec. 122, 68 Stat. 939 (42 U.S.C. 2152). Section 70.31 also issued under sec. 57d, Pub. L. 93-377, 88 Stat. 475 (42 U.S.C. 2077). Sections 70.36 and 70.44 also issued under sec. 184, 68 Stat. 954, as amended (42 U.S.C. 2234). Section 70.61 also issued under secs. 186, 187, 68 12
Stat. 955 {42 U.S.C. 2236, 2237). Section 70.62 also issued under sec. 108, 68 Stat. 939, as amended {42 U.S.C. 2138).
- 8.
In§ 70.1, A new paragraph {e) is added to read as follows: § 70.1 Purpose. (e) As provided in the Atomic Energy Act of 1954, as amended, the regulations in this part establish requirements, procedures, and criteria for the issuance of licenses to uranium enrichment facilities.
- 9.
In§ 70.4, the term *corporationn is added to read as follows: § 70.4 Definitions. Corporation means the United States Enrichment Corporation (USEC),. or its successor, a Corporation that is authorized by statute to lease the -- gaseous diffusion enrichment plants in Paducah, Kentucky, and Piketon, Ohio, from the Department of Energy, or_any person authorized to operate one or both of the gaseous diffusion plants, or other facilities, pursuant to a plan for the privatization of USEC that is approved by the President.
- 10. A new§ 70.40 is added to read as follows:
§ 70.40 Ineligibility of certain applicants. 13
A license may not be issued to the Corporation if the Comnission detennines that: {a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a license would be inimical to-(1) The common defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services. PART 76 -- CERTIFICATION OF GASEOUS DIFFUSION PLANTS
- 11. The authority citation for Part 76 is revised to read as follows:
AUTHORITY: Secs. 161, 68 Stat. 948, as amended, secs. 1312, 1701, as amended, 106 Stat. 2932, 2951, 2952, 2953, 110 Stat. 1321-349, {42 U.S.C. 2201, 2297b-ll, 2297f); secs. 201, as amended, 204, 206, 88 Stat. 1244, 1245, 1246 (42 U.S.C. 5841, 5842, 5845, 5846); sec. 234(a), 83 Stat. 444, as amended by Pub. L. 104-134, 110 Stat. 1321", 1321-349 (42 U.S.C. 2243(a)). Sec. 76.7 also issued under Pub. L. 95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851). Sec. 76.22 is also issued under sec. 193(f), as amended, 104 Stat. 2835, as amended by Pub. L. 104-134, 110 Stat. 1321, 1321-349 (42 U.S.C. 2243(f)). Sec. 76.35(j) also issued under sec. 122, 68 Stat. 939 (42rU.S.C. 2152).
- 12.
In§ 76.4, the tenn *corporation" is amended to read as follows and the term *uranium enrichment plant" is removed: § 76.4 Definitions. 14
Corporation means the United States Enrichment Corporation (USEC), or its successor, a Corporation that is authorized by statute to lease the gaseous diffusion enrichment plants in Paducah, Kentucky, and Piketon, Ohio, from the Department of Energy, or any person authorized to operate one or both of the gaseous diffusion plants, or other facilities, pursuant to a plan for the privatization of USEC that is approved by the President.
- 13. In§ 76.10, paragraph (b) is revised to read as follows:
§ 76.10 Deliberate misconduct. (b) A person who violates paragraph (a)(l) or (a)(2) of this section may be subject to enforcement action in accordance with the procedures in 10 CFR Part 2, subpart B.
- 14.
In§ 76.21, paragraph (b) is revised to read as follows:
- 76.21 Certificate required.
{b) For the purposes of§§ 30.41, 40.51, and 70.42 of this chapter, the Corporation shall be authorized to receive, and licensees shall be authorized to transfer to the Corporation, byproduct material, source material, or 15
special nuclear material to the extent permitted under the certificate of compliance issued, and/or the compliance plan approved, pursuant to this part.
- 15. A new§ 76.22 is added to read as follows:
§ 76.22 Ineligibility of certain applicants. A certificate of compliance may not be issued to the Corporation if the Conunission determines that: (a) The Corporation is owned, controlled, or dominated by an alien, a foreign corporation, or a foreign government; or (b) The issuance of such a certificate of compliance would be inimical to-(1} The co11111on defense and security of the United States; or (2) The maintenance of a reliable and economical domestic source of enrichment services.
- 16. Section 76.31 is revised to read as follows:
§ 76.31 Periodic application requirement.
- The Corporation shall periodically apply to the Convnission for a certificate of compliance, in accordance with§ 76.36, on or before April 15 of the year specified in an existing certificate of compliance as determined by the Commission, but not less frequently than every 5 years.
- 17.
In§ 76.35, paragraph (n) is revised to read as follows: § 76.35 Contents of initial application. 16
(n) A description of the funding program to be established to ensure that funds will be set aside and available for those aspects of the ultimate disposal of waste and depleted uranium, decontamination and decommissioning, relating to the gaseous diffusion plants leased to the Corporation by the Department of Energy, which are the financial responsibility of the Corporation. The Corporation shall establish financial surety arrangements to ~nsure that sufficient funds will be available for the ultimate disposal -of-waste and depleted uranium, and decontamination and decomnissioning activities which are the financial responsibility of the Corporation. The funding mechanism, such as prepayment, surety, insurance, or external sinking fund, must ensure availability of funds for any activities which are required to be completed both before or after the return of the gaseous diffusion facilities to the Department of Energy in accordance with the lease between the Department and the Corporation. The funding program must contain a basis for cost estimates used to establish funding levels and must contain means of adjusting cost estimates and associated funding levels over the duration of the lease. The funding program need not address funding for those asp~c;__t~ of decontamination and decomnissioning of the gaseous diffusion plants -assigned to the Department of Energy under the Atomic Energy Act of 1954, as amended. The Corporation should address the adequacy of the financing mechanism selected in its periodic application for certification.
- 18.
In§ 76.36, the section heading and paragraph (a) are revised to read as follows: § 76.36 Renewals. 17
(a) After issuance by the Corrvnission of the initial certificate of compliance and/or an approved compliance plan, the Corporation shall file periodic applications for renewal, as required by§ 76.31.
- 19. Section 76.43 is revised to read as follows:
§ 76,43 Date for decision. The Director will render a decision on an application within 6 months of the receipt of the application unless the Director alters the date for decision and publishes notice of the new date in the Federal Register.
- 20.
In§ 76.45, paragraph (a) is revised to read as follows: § 76.45 Application for amendment of certificate. (a) Contents of amendment app]jcatjon. In addition to the application for certification submitted pursuant to§ 76.31, the Corporation may at any time apply for amendment of the certificate to cover proposed new or modified activities. The amendment application should contain sufficient information for the Director to make findings of compliance or acceptability for the proposed activities as required for the original certificate.
- 21.
Section 76.55 is revised to read as follows: § 76.55 Timely renewal. In any case in which the Corporation has timely filed a sufficient application for a certificate of compliance, the existing certificate of compliance or approved compliance plan does not expire until the application 18
for a certificate of compliance has been finally detennined by the NRC. For purposes of this rule, a sufficient application is one that addresses all elements of§ 76.36.
- 22.
In§ 76.60, paragraphs (c)(l), and (d)(l), are removed and reserved and paragraph (i) is revised to read as follows: § 76.60 Regulatory requirements which apply. (c) (1) [Reserved] (d) (1) [Reserved] (i) The Corporation shall comply with the applicable provisions of 10 CFR Part 95, "Security Facility Approval and Safeguarding of National Security Infonnation and Restricted Data, 11 as specified in subpart E to this part. 19
- 23.
In§ 76.66, paragraph (c) is revised to read as follows: § 76.66 Expiration and termination of certificates. (c) If the Corporation does not submit a renewal application under § 76.36, the Corporation shall, on or before the expiration date specified in the existing certificate, tenninate operation of the gaseous diffusion plants.
- 24.
In§ 76.68, paragraph (b) is revised to read as follows: § 76.68 Plant changes. (b) To ensure that the approved application remains current with respect to the actual site description and that the plant's programs, plans, policies, and operations are in place, the Corporation shall submit revised pages to the approved application and safety analysis report, marked and dated to indicate each change. The Corporation shall evaluate any as-found conditions that do not agree with the plant's programs, plans, policies, and operations in accordance with paragraph (a) of this section. These revisions must be submitted before April 15 of each calendar year, or at a shorter interval as may be specified in the certificate. If a renewal application for a certificate is filed in accordance with§ 76.36 of this part, the revisions shall be incorporated into the application. 20
- 25.
In§ 76.72, paragraph (d) is revised to read as follows: § 76.72 Miscellaneous procedural matters. (d) The procedures set forth in 10 CFR 2.205, and in 10 CFR Part 2, subpart G, will be applied in connection with NRC action to impose a civil penalty pursuant to Se~tion-234 of the Atomic Energy Act of-1954, as amended, or Section* 206 of the Energy Reorganization Act of 1974 and the implementing regulations in 10 CFR Part 21 (Reporting of Defects and Noncompliance), as authorized by Section 1312(e) of the Atomic Energy Act of 1954, as amended;
- 26.
In§ 76.76, paragraph (a)(2) is revised to read as follows: § 76.76 Backfitting. v (a) (2) Except as provided in paragraph (a)(4) of this section, the Con111i ss ion sha 11 require a systematic and documented analysis_ pursuant to paragraph (b) of this section for backfits which it seeks to impose.
- 27.
Section 76.111 is revised to read as follows: § 76.111 Physical security, material control and accounting, and protection of certain information. 21
- Jrl
Nuclear Regulatory Commission regulations that will be used for certification of the Corporation 1 for physical security and material control and accounting are contained in Title 10 of the Code of Federal Regulations as described in this subpart. The regulations referenced in this subpart contain requirements for physical security and material control and accounting for formula quantities of strategic special nuclear material {Category I), special nuclear material of moderate strategic significance {Category II), and special nuclear material of low strategic significance {Category III), and for protection of Restricted Data, National Security Information, Safeguards Information, and information designated by the U.S. Department of Energy as Unclassified Controlled Nuclear Information.
- 28.
In§ 76.113, paragraph {c) is revised to read as follows: § 76.113 Formula quantities of strategic special nuclear material-Category I. {c) The requirements for the protection of Safeguards Information pertaining to formula quantity of strategic special nuclear material {Category I) are contained in§ 73.21. Information designated by the U.S. Department of Energy as Unclassified Controlled Nuclear Information must be protected at a level equivalent to that accorded Safeguards Information. 1For the purpose of this subpart, the terms "licenseew or wlicense" used in parts 70, 73, and 74 of this chapter, mean, respectively, the Corporation, or the certificate of compliance or approved compliance plan. 22
- 29.
Section 76.131 is revised to read as follows: § 76.131 Violations. (a) The Commission may obtain an injunction or other court order to prevent a violation of the provisions of: (1) The Atomic Energy Act of 1954, as amended; (2) Title II of the Energy Reorganization Act of 1974, as amended; (3) A regulation or order issued pursuant to those Acts. {b) The Commission may obtain a court order for the payment of a civil penalty imposed under Section 234 of the Atomic Energy*Act of 1954, as amended, or under Section 1312{e) of the Atomic Energy Act of 1954, as amended, and Section 206 of the Energy Reorganization Act of 1974, as amended, for violations of: (1) Sections 53, 57, 62, 63, 81, 82, 101, 103, 104, 107, 109, or 1701 of the Atomic Energy Act of 1954, as amended; (2) Section 206 of the Energy Reorganization Act; (3) Any rule, regulation, or order issued pursuant to the sections specified in paragraph {b){l) of this section; 23 , (,t,
(4) Any term, condition, or limitation of any certificate of compliance or approved compliance plan. issued under the sections specified in paragraph (b)(l) of this section. Dated at Rockville, Maryland, this t f"'::1 day of February, 1997. For the Nuclear Regulatory Commission. 24 I,}}