ML23089A149
| ML23089A149 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 03/30/2023 |
| From: | Ameren Missouri, Union Electric Co |
| To: | Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML23089A145 | List: |
| References | |
| ULNRC-06798 | |
| Download: ML23089A149 (1) | |
Text
Enclosure3to ULNRC06798 Updatedfor2023Filing 105.00
=1986$Cost
[From10CFR50.75(c)(1)(i)ForPWR3400MWt]
3.178 =Lx U.S.DepartmentofLabor,BureauofLaborStatistics; EmploymentCostIndexfortotalcompensation,forprivateindustryworkers,bybargainingstatus,census regionanddivision,andmetropolitanareastatus MidwestRegion BaseLx=2.080(December2005=100)
December2022ECI=152.8(December2005=100)
Lx=[(BaseLx/100)*ECI]
3.443 =Ex FromNUREG1307Revision19 Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
DeterminePxValue 2.451 =Px U.S.DepartmentofLabor,BureauofLaborStatistics; ProducerPriceIndexCommodities SeriesID:WPU0543 NotSeasonallyAdjusted Fuelsandrelatedproductsandpower Industrialelectricpower 1982=100 January1986ValueofPPISeriesIDWPU0543=114.200 December2022ValueofPPISeriesIDWPU0543=279.934 Px=December2022ValueofPPISeriesIDWPU0543/January1986ValueofPPISeriesIDWPU0543 DetermineFxValue 4.813 =Fx U.S.DepartmentofLabor,BureauofLaborStatistics; ProducerPriceIndexCommodities SeriesID:WPU0573 NotSeasonallyAdjusted Fuelsandrelatedproductsandpower Lightfueloils 1982=100 January1986ValueofPPISeriesIDWPU0573=82.000 December2022ValueofPPISeriesIDWPU0573=394.700 Fx=December2022ValueofPPISeriesIDWPU0573/January1986ValueofPPISeriesIDWPU0573 13.711 =Bx FromNUREG1307Revision19 Table21 BxValuesforGeneratorsLocatedintheUnaffiliatedStatesandthoseLocatedinCompactAffiliatedStates havingnoDisposalFacility PWR CalculatetheDecommissioningCostEstimateDecember2022$
EstimatedCost(Yearx)=[1986$Cost]*[(A*Lx)+(B*Ex)+(C*Bx)]
0.65 =LxCoefficient(A) 0.13 =ExCoefficient(B) 0.22 =BxCoeficcient(C) 580.597
=EstimatedDecember2022$Cost DetermineEstimatedDecommissioningCostsin1986Dollars:
CalculateLaborAdjustmentFactor(Lx):
CalculateEnergyAdjustmentFactor(Ex):
CalculateWasteBurialAdjustmentFactor(Bx):
MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS
($Millions)
Page1of18 to ULNRC06798 EstimatedCost(Yearx)=[1986$Cost]*[(A*Lx)+(B*Ex)+(C*Bx)]
Year$
1986 Cost Lx Coefficient (A)
Lx (UseDecof Yearx1 Value)
Ex Coefficient (B)
Ex (UseDecof Yearx Value)
Bx Coefficient (C)
Bx (UseYearxValues fromNUREG1307)
TotalEstimated DecommissioningCost (DecemberYearxx$)
Jan1986 105.000 0.65 1.000 0.13 1.000 0.22 1.000 105.000 Dec1986 105.000 0.65 1.028 0.13 0.804 0.22 1.000 104.241 Dec1987 105.000 0.65 1.057 0.13 0.854 0.22 2.007 130.161 Dec1988 105.000 0.65 1.108 0.13 0.820 0.22 2.007 133.150 Dec1989 105.000 0.65 1.152 0.13 0.929 0.22 2.007 137.697 Dec1990 105.000 0.65 1.211 0.13 1.061 0.22 2.494 154.756 Dec1991 105.000 0.65 1.269 0.13 0.954 0.22 2.494 157.227 Dec1992 105.000 0.65 1.313 0.13 0.948 0.22 11.408 366.065 Dec1993 105.000 0.65 1.371 0.13 0.903 0.22 11.873 380.135 Dec1994 105.000 0.65 1.414 0.13 0.927 0.22 12.824 405.364 Dec1995 105.000 0.65 1.451 0.13 0.959 0.22 12.771 407.120 Dec1996 105.000 0.65 1.494 0.13 1.038 0.22 15.852 482.307 Dec1997 105.000 0.65 1.548 0.13 0.956 0.22 15.886 485.671 Dec1998 105.000 0.65 1.599 0.13 0.842 0.22 15.886 487.586 Dec1999 105.000 0.65 1.654 0.13 1.016 0.22 8.052 312.780 Dec2000 105.000 0.65 1.734 0.13 1.189 0.22 8.052 320.549 Dec2001 105.000 0.65 1.793 0.13 0.985 0.22 9.467 354.540 Dec2002 105.000 0.65 1.861 0.13 1.142 0.22 9.467 361.316 Dec2003 105.000 0.65 1.951 0.13 1.216 0.22 7.934 333.013 Dec2004 105.000 0.65 2.012 0.13 1.428 0.22 7.934 340.066 Dec2005 105.000 0.65 2.080 0.13 1.811 0.22 8.683 367.233 Dec2006 105.000 0.65 2.138 0.13 1.879 0.22 8.683 372.126 Dec2007 105.000 0.65 2.190 0.13 2.280 0.22 9.872 408.621 Dec2008 105.000 0.65 2.238 0.13 1.791 0.22 9.872 405.211 Dec2009 105.000 0.65 2.258 0.13 1.956 0.22 12.280 464.508 Dec2010 105.000 0.65 2.315 0.13 2.253 0.22 12.280 472.385 Dec2011 105.000 0.65 2.369 0.13 2.580 0.22 12.280 480.542 Dec2012 105.000 0.65 2.410 0.13 2.639 0.22 13.885 521.269 Dec2013 105.000 0.65 2.450 0.13 2.570 0.22 13.885 523.015 Dec2014 105.000 0.65 2.502 0.13 2.208 0.22 13.885 521.620 Dec2015 105.000 0.65 2.547 0.13 1.762 0.22 12.471 486.003 Dec2016 105.000 0.65 2.614 0.13 1.860 0.22 12.471 491.882 Dec2017 105.000 0.65 2.672 0.13 2.295 0.22 12.853 510.614 Dec2018 105.000 0.65 2.751 0.13 2.359 0.22 12.853 516.873 Dec2019 105.000 0.65 2.822 0.13 2.305 0.22 12.853 520.969 Dec2020 105.000 0.65 2.893 0.13 2.255 0.22 12.793 523.724 Dec2021 105.000 0.65 3.026 0.13 2.933 0.22 12.793 542.061 Dec2022 105.000 0.65 3.178 0.13 3.443 0.22 13.711 580.597 MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS
($Millions) 0 100 200 300 400 500 600 700
$Millions NRCMinimumCostEstimates($Millions) to ULNRC06798 LaborAdjustmentFactor(Lx)Derivation 124.6 =Dec1985IndexValueJune1981=100 1.409=Multiplier:ConversionofJune1989=100IndexValuestoJune1981=100IndexValues 1.839 =Multiplier:ConversionofDec2005=100IndexValuestoJune1989=100IndexValues IndexDate IndexValue IndexBaseYear IndexValue IndexBaseYear IndexValue IndexBaseYear Lx AtIndexdate MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Mar1986 125.9 June1981=100 1.010
Jun1986 126.2 June1981=100 1.013
Sep1986 127.3 June1981=100 1.022
Dec1986 128.1 June1981=100 1.028
Mar1987 129.1 June1981=100 1.036
Jun1987 130.2 June1981=100 1.045
Sep1987 131.2 June1981=100 1.053
Dec1987 131.7 June1981=100 1.057
Mar1988 134.4 June1981=100 1.079
Jun1988 135.5 June1981=100 1.087
Sep1988 136.7 June1981=100 1.097
Dec1988 138.0 June1981=100 1.108
Mar1989 139.3 June1981=100 98.9 June1989=100 1.118
Jun1989 140.9 June1981=100 100.0 June1989=100 1.131
Sep1989 142.3 June1981=100 101.0 June1989=100 1.142
Dec1989 143.6 June1981=100 101.9 June1989=100 1.152
Mar1990 145.8 103.5 June1989=100 1.170
Jun1990 147.7 104.8 June1989=100 1.185
Sep1990 149.8 106.3 June1989=100 1.202
Dec1990 150.9 107.1 June1989=100 1.211
Mar1991 152.9 108.5 June1989=100 1.227
Jun1991 154.6 109.7 June1989=100 1.241
Sep1991 156.7 111.2 June1989=100 1.257
Dec1991 158.1 112.2 June1989=100 1.269
Mar1992 160.3 113.8 June1989=100 1.287
Jun1992 161.5 114.6 June1989=100 1.296
Sep1992 162.5 115.3 June1989=100 1.304
Dec1992 163.6 116.1 June1989=100 1.313
Mar1993 166.1 117.9 June1989=100 1.333
Jun1993 168.1 119.3 June1989=100 1.349
Sep1993 169.2 120.1 June1989=100 1.358
Dec1993 170.8 121.2 June1989=100 1.371
Mar1994 173.0 122.8 June1989=100 1.389
Jun1994 174.2 123.6 June1989=100 1.398
Sep1994 175.6 124.6 June1989=100 1.409
Dec1994 176.1 125.0 June1989=100 1.414
Mar1995 177.3 125.8 June1989=100 1.423
Jun1995 178.8 126.9 June1989=100 1.435
Sep1995 179.9 127.7 June1989=100 1.444
Dec1995 180.8 128.3 June1989=100 1.451
Mar1996 182.5 129.5 June1989=100 1.464
Jun1996 184.2 130.7 June1989=100 1.478
Sep1996 185.0 131.3 June1989=100 1.485
Dec1996 186.1 132.1 June1989=100 1.494
Mar1997 187.8 133.3 June1989=100 1.507
Jun1997 189.8 134.7 June1989=100 1.523
Sep1997 191.9 136.2 June1989=100 1.540
Dec1997 192.9 136.9 June1989=100 1.548
Mar1998 194.9 138.3 June1989=100 1.564
Jun1998 196.7 139.6 June1989=100 1.579
Sep1998 198.5 140.9 June1989=100 1.593
Dec1998 199.2 141.4 June1989=100 1.599
Mar1999 199.7 141.7 June1989=100 1.602
Jun1999 202.3 143.6 June1989=100 1.624
Sep1999 204.3 145.0 June1989=100 1.640
Dec1999 206.1 146.3 June1989=100 1.654
Mar2000 209.8 148.9 June1989=100 1.684
Page3of18 to ULNRC06798 LaborAdjustmentFactor(Lx)Derivation 124.6 =Dec1985IndexValueJune1981=100 1.409=Multiplier:ConversionofJune1989=100IndexValuestoJune1981=100IndexValues 1.839 =Multiplier:ConversionofDec2005=100IndexValuestoJune1989=100IndexValues IndexDate IndexValue IndexBaseYear IndexValue IndexBaseYear IndexValue IndexBaseYear Lx AtIndexdate MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Jun2000 212.3 150.7 June1989=100 1.704
Sep2000 214.4 152.2 June1989=100 1.721
Dec2000 216.0 153.3 June1989=100 1.734
Mar2001 218.1 154.8 June1989=100 84.8 Dec2005=100 1.751
Jun2001 219.8 156.0 June1989=100 85.4 Dec2005=100 1.764
Sep2001 221.8 157.4 June1989=100 86.1 Dec2005=100 1.780
Dec2001 223.5 158.6 June1989=100 86.7 Dec2005=100 1.793
Mar2002 227.0 161.1 June1989=100 88.0 Dec2005=100 1.822
Jun2002 229.1 162.6 June1989=100 88.7 Dec2005=100 1.839
Sep2002 230.4 163.5 June1989=100 89.0 Dec2005=100 1.849
Dec2002 231.9 164.6 June1989=100 89.5 Dec2005=100 1.861
Mar2003 238.1 169.0 June1989=100 92.1 Dec2005=100 1.911
Jun2003 240.1 170.4 June1989=100 92.8 Dec2005=100 1.927
Sep2003 241.9 171.7 June1989=100 93.6 Dec2005=100 1.942
Dec2003 243.1 172.5 June1989=100 94.0 Dec2005=100 1.951
Mar2004 246.2 174.7 June1989=100 95.0 Dec2005=100 1.976
Jun2004 248.3 176.2 June1989=100 95.9 Dec2005=100 1.993
Sep2004 250.2 177.6 June1989=100 96.6 Dec2005=100 2.008
Dec2004 250.7 177.9 June1989=100 96.9 Dec2005=100 2.012
Mar2005 253.6 180.0 June1989=100 97.8 Dec2005=100 2.035
Jun2005 254.9 180.9 June1989=100 98.4 Dec2005=100 2.046
Sep2005 257.8 183.0 June1989=100 99.5 Dec2005=100 2.069
Dec2005 259.1 183.9 June1989=100 100.0 Dec2005=100 2.080
Mar2006 260.9 185.2 100.7 Dec2005=100 2.094
Jun2006 263.5 187.0 101.7 Dec2005=100 2.115
Sep2006 265.1 188.1 102.3 Dec2005=100 2.127
Dec2006 266.4 189.0 102.8 Dec2005=100 2.138
Mar2007 267.7 190.0 103.3 Dec2005=100 2.148
Jun2007 270.0 191.6 104.2 Dec2005=100 2.167
Sep2007 271.0 192.4 104.6 Dec2005=100 2.175
Dec2007 272.8 193.6 105.3 Dec2005=100 2.190
Mar2008 274.7 194.9 106.0 Dec2005=100 2.204
Jun2008 277.3 196.8 107.0 Dec2005=100 2.225
Sep2008 278.3 197.5 107.4 Dec2005=100 2.233
Dec2008 278.8 197.9 107.6 Dec2005=100 2.238
Mar2009 279.6 198.4 107.9 Dec2005=100 2.244
Jun2009 280.1 198.8 108.1 Dec2005=100 2.248
Sep2009 280.9 199.3 108.4 Dec2005=100 2.254
Dec2009 281.4 199.7 108.6 Dec2005=100 2.258
Mar2010 284.8 202.1 109.9 Dec2005=100 2.285
Jun2010 286.1 203.0 110.4 Dec2005=100 2.296
Sep2010 287.6 204.1 111.0 Dec2005=100 2.308
Dec2010 288.4 204.7 111.3 Dec2005=100 2.315
Mar2011 290.7 206.3 112.2 Dec2005=100 2.333
Jun2011 293.6 208.4 113.3 Dec2005=100 2.356
Sep2011 294.4 208.9 113.6 Dec2005=100 2.362
Dec2011 295.1 209.5 113.9 Dec2005=100 2.369
Mar2012 297.2 210.9 114.7 Dec2005=100 2.385
Jun2012 298.8 212.0 115.3 Dec2005=100 2.398
Sep2012 299.5 212.6 115.6 Dec2005=100 2.404
Dec2012 300.3 213.1 115.9 Dec2005=100 2.410
Mar2013 301.6 214.1 116.4 Dec2005=100 2.421
Jun2013 303.2 215.2 117.0 Dec2005=100 2.433
Sep2013 304.2 215.9 117.4 Dec2005=100 2.441
Dec2013 305.2 216.6 117.8 Dec2005=100 2.450
Mar2014 306.8 217.7 118.4 Dec2005=100 2.462
Jun2014 309.6 219.8 119.5 Dec2005=100 2.485
Page4of18 to ULNRC06798 LaborAdjustmentFactor(Lx)Derivation 124.6 =Dec1985IndexValueJune1981=100 1.409=Multiplier:ConversionofJune1989=100IndexValuestoJune1981=100IndexValues 1.839 =Multiplier:ConversionofDec2005=100IndexValuestoJune1989=100IndexValues IndexDate IndexValue IndexBaseYear IndexValue IndexBaseYear IndexValue IndexBaseYear Lx AtIndexdate MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Sep2014 310.9 220.7 120.0 Dec2005=100 2.495
Dec2014 311.7 221.2 120.3 Dec2005=100 2.502
Mar2015 314.0 222.9 121.2 Dec2005=100 2.520
Jun2015 314.6 223.3 121.4 Dec2005=100 2.525
Sep2015 316.4 224.5 122.1 Dec2005=100 2.539
Dec2015 317.4 225.3 122.5 Dec2005=100 2.547
Mar2016 319.7 226.9 123.4 Dec2005=100 2.566
Jun2016 322.6 229.0 124.5 Dec2005=100 2.589
Sep2016 324.7 230.4 125.3 Dec2005=100 2.606
Dec2016 325.7 231.2 125.7 Dec2005=100 2.614
Mar2017 328.6 233.2 126.8 Dec2005=100 2.637
Jun2017 330.1 234.3 127.4 Dec2005=100 2.649
Sep2017 331.7 235.4 128.0 Dec2005=100 2.662
Dec2017 333.0 236.3 128.5 Dec2005=100 2.672
Mar2018 336.3 238.7 129.8 Dec2005=100 2.699
Jun2018 338.4 240.2 130.6 Dec2005=100 2.716
Sep2018 341.0 242.0 131.6 Dec2005=100 2.737
Dec2018 342.8 243.3 132.3 Dec2005=100 2.751
Mar2019 345.9 245.5 133.5 Dec2005=100 2.776
Jun2019 347.5 246.6 134.1 Dec2005=100 2.789
Sep2019 349.8 248.3 135.0 Dec2005=100 2.807
Dec2019 351.6 249.6 135.7 Dec2005=100 2.822
Mar2020 356.3 252.9 137.5 Dec2005=100 2.859
Jun2020 356.5 253.0 137.6 Dec2005=100 2.861
Sep2020 358.1 254.1 138.2 Dec2005=100 2.874
Dec2020 360.4 255.8 139.1 Dec2005=100 2.893
Mar2021 364.6 258.7 140.7 Dec2005=100 2.926
Jun2021 367.4 260.8 141.8 Dec2005=100 2.949
Sep2021 371.8 263.9 143.5 Dec2005=100 2.984
Dec2021 377.0 267.6 145.5 Dec2005=100 3.026
Mar2022 383.2 272.0 147.9 Dec2005=100 3.076
Jun2022 388.4 275.7 149.9 Dec2005=100 3.117
Sep2022 393.3 279.2 151.8 Dec2005=100 3.157
Dec2022 395.9 281.0 152.8 Dec2005=100 3.178
Series Id:
Not seasonally adjusted Series
Title:
Total compensation for Private industry workers in Midwest, Index Ownership:
Component:
Occupation:
Industry:
Subcategory:
Area:
Midwest census region Employment Cost Index Original Data Value CIU2010000000230I Private industry workers Total compensation All workers All workers All workers Page5of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex Dec1985 112.9 89.400 Jan1986 114.2 1.000 82.000 1.000 1.000 Feb1986 115.0 1.007 62.400 0.761 0.904 Mar1986 114.4 1.002 51.300 0.626 0.844 Apr1986 113.7 0.996 49.800 0.607 0.833 May1986 114.1 0.999 47.000 0.573 0.820 Jun1986 115.3 1.010 44.700 0.545 0.815 Jul1986 116.2 1.018 36.400 0.444 0.777 Aug1986 116.3 1.018 40.100 0.489 0.796 Sep1986 116.3 1.018 46.300 0.565 0.828 Oct1986 113.0 0.989 43.100 0.526 0.795 Nov1986 112.7 0.987 43.500 0.530 0.795 Dec1986 112.3 0.983 45.600 0.556 0.804 Jan1987 110.3 0.966 51.400 0.627 0.823 Feb1987 109.8 0.961 53.100 0.648 0.830 Mar1987 110.2 0.965 49.700 0.606 0.814 Apr1987 109.9 0.962 52.000 0.634 0.825 May1987 111.8 0.979 53.300 0.650 0.841 Jun1987 113.9 0.997 55.100 0.672 0.861 Jul1987 116.2 1.018 56.300 0.687 0.879 Aug1987 115.7 1.013 59.400 0.724 0.892 Sep1987 115.5 1.011 56.800 0.693 0.878 Oct1987 111.0 0.972 59.300 0.723 0.867 Nov1987 109.2 0.956 61.200 0.746 0.868 Dec1987 109.6 0.960 58.100 0.709 0.854 Jan1988 108.8 0.953 54.800 0.668 0.833 Feb1988 109.0 0.954 51.500 0.628 0.817 Mar1988 109.0 0.954 49.700 0.606 0.808 Apr1988 109.1 0.955 53.300 0.650 0.827 May1988 108.9 0.954 54.300 0.662 0.831 Jun1988 117.2 1.026 50.600 0.617 0.854 Jul1988 118.2 1.035 46.900 0.572 0.841 Aug1988 118.3 1.036 46.800 0.571 0.841 Sep1988 118.5 1.038 45.900 0.560 0.837 Oct1988 114.2 1.000 42.300 0.516 0.797 Nov1988 109.2 0.956 47.200 0.576 0.796 Dec1988 110.5 0.968 50.600 0.617 0.820 Jan1989 112.0 0.981 54.900 0.670 0.850 Feb1989 112.0 0.981 54.000 0.659 0.845 Mar1989 112.3 0.983 57.300 0.699 0.864 Apr1989 112.4 0.984 61.500 0.750 0.886 May1989 113.6 0.995 57.500 0.701 0.871 Jun1989 119.8 1.049 53.300 0.650 0.881 Jul1989 122.2 1.070 52.700 0.643 0.891 MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Page6of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Aug1989 122.4 1.072 53.500 0.652 0.896 Sep1989 122.5 1.073 59.300 0.723 0.926 Oct1989 117.2 1.026 64.000 0.780 0.923 Nov1989 113.5 0.994 64.400 0.785 0.906 Dec1989 114.2 1.000 68.100 0.830 0.929 Jan1990 114.9 1.006 85.300 1.040 1.020 Feb1990 115.0 1.007 59.400 0.724 0.888 Mar1990 115.4 1.011 60.400 0.737 0.895 Apr1990 115.1 1.008 61.000 0.744 0.897 May1990 117.0 1.025 58.400 0.712 0.893 Jun1990 123.9 1.085 53.000 0.646 0.901 Jul1990 124.4 1.089 51.600 0.629 0.896 Aug1990 124.6 1.091 72.300 0.882 1.003 Sep1990 125.0 1.095 87.300 1.065 1.082 Oct1990 121.2 1.061 104.800 1.278 1.152 Nov1990 120.2 1.053 98.900 1.206 1.117 Dec1990 118.9 1.041 89.300 1.089 1.061 Jan1991 124.2 1.088 82.900 1.011 1.055 Feb1991 124.3 1.088 74.300 0.906 1.012 Mar1991 124.3 1.088 61.600 0.751 0.947 Apr1991 124.7 1.092 60.000 0.732 0.941 May1991 128.2 1.123 59.600 0.727 0.956 Jun1991 132.6 1.161 57.600 0.702 0.968 Jul1991 134.5 1.178 58.100 0.709 0.981 Aug1991 133.8 1.172 62.100 0.757 0.998 Sep1991 133.8 1.172 65.400 0.798 1.015 Oct1991 128.3 1.123 67.600 0.824 0.998 Nov1991 123.1 1.078 71.000 0.866 0.989 Dec1991 125.1 1.095 62.200 0.759 0.954 Jan1992 125.9 1.102 54.400 0.663 0.918 Feb1992 125.3 1.097 57.300 0.699 0.930 Mar1992 125.8 1.102 56.000 0.683 0.926 Apr1992 124.8 1.093 59.000 0.720 0.936 May1992 128.5 1.125 62.100 0.757 0.971 Jun1992 134.8 1.180 65.400 0.798 1.020 Jul1992 135.6 1.187 64.600 0.788 1.020 Aug1992 135.1 1.183 63.300 0.772 1.010 Sep1992 135.9 1.190 65.600 0.800 1.026 Oct1992 131.2 1.149 68.200 0.832 1.016 Nov1992 125.5 1.099 64.200 0.783 0.966 Dec1992 126.7 1.109 59.400 0.724 0.948 Jan1993 127.1 1.113 59.000 0.720 0.948 Feb1993 126.4 1.107 60.400 0.737 0.951 Mar1993 126.7 1.109 63.200 0.771 0.967 Page7of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Apr1993 126.8 1.110 62.400 0.761 0.964 May1993 127.5 1.116 62.600 0.763 0.968 Jun1993 136.9 1.199 60.800 0.741 1.007 Jul1993 137.1 1.201 57.000 0.695 0.988 Aug1993 137.2 1.201 54.400 0.663 0.975 Sep1993 137.6 1.205 59.300 0.723 1.003 Oct1993 131.9 1.155 65.400 0.798 1.005 Nov1993 126.3 1.106 61.600 0.751 0.957 Dec1993 126.0 1.103 51.400 0.627 0.903 Jan1994 126.2 1.105 51.500 0.628 0.905 Feb1994 125.9 1.102 57.500 0.701 0.934 Mar1994 125.8 1.102 56.200 0.685 0.927 Apr1994 125.4 1.098 54.700 0.667 0.917 May1994 126.0 1.103 54.700 0.667 0.920 Jun1994 133.5 1.169 54.100 0.660 0.955 Jul1994 134.5 1.178 56.300 0.687 0.971 Aug1994 134.5 1.178 57.500 0.701 0.978 Sep1994 134.9 1.181 57.700 0.704 0.981 Oct1994 129.1 1.130 57.700 0.704 0.951 Nov1994 127.0 1.112 58.800 0.717 0.946 Dec1994 127.4 1.116 54.700 0.667 0.927 Jan1995 127.6 1.117 54.700 0.667 0.928 Feb1995 128.0 1.121 53.300 0.650 0.923 Mar1995 128.3 1.123 54.300 0.662 0.930 Apr1995 126.4 1.107 57.100 0.696 0.934 May1995 130.2 1.140 59.100 0.721 0.964 Jun1995 135.3 1.185 55.800 0.680 0.973 Jul1995 136.6 1.196 53.500 0.652 0.968 Aug1995 136.5 1.195 55.600 0.678 0.978 Sep1995 133.7 1.171 58.200 0.710 0.977 Oct1995 131.4 1.151 57.800 0.705 0.963 Nov1995 127.6 1.117 59.500 0.726 0.953 Dec1995 127.7 1.118 60.600 0.739 0.959 Jan1996 127.9 1.120 62.600 0.763 0.970 Feb1996 127.1 1.113 59.700 0.728 0.951 Mar1996 127.8 1.119 63.500 0.774 0.974 Apr1996 129.1 1.130 74.700 0.911 1.038 May1996 135.0 1.182 72.000 0.878 1.054 Jun1996 137.5 1.204 62.800 0.766 1.020 Jul1996 136.0 1.191 64.300 0.784 1.020 Aug1996 136.2 1.193 66.500 0.811 1.032 Sep1996 136.2 1.193 73.400 0.895 1.068 Oct1996 131.2 1.149 79.700 0.972 1.075 Nov1996 127.1 1.113 76.500 0.933 1.037 Page8of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Dec1996 127.7 1.118 76.100 0.928 1.038 Jan1997 128.3 1.123 73.700 0.899 1.029 Feb1997 128.1 1.122 72.300 0.882 1.021 Mar1997 128.2 1.123 65.200 0.795 0.985 Apr1997 127.3 1.115 65.300 0.796 0.981 May1997 129.7 1.136 64.200 0.783 0.988 Jun1997 135.1 1.183 60.800 0.741 0.998 Jul1997 135.9 1.190 57.800 0.705 0.986 Aug1997 134.7 1.180 61.500 0.750 0.999 Sep1997 136.0 1.191 60.400 0.737 1.000 Oct1997 130.1 1.139 64.800 0.790 0.993 Nov1997 127.9 1.120 65.800 0.802 0.987 Dec1997 128.3 1.123 59.400 0.724 0.956 Jan1998 127.4 1.116 54.100 0.660 0.924 Feb1998 127.2 1.114 52.000 0.634 0.912 Mar1998 126.7 1.109 48.300 0.589 0.891 Apr1998 126.4 1.107 50.200 0.612 0.899 May1998 129.2 1.131 50.000 0.610 0.912 Jun1998 133.8 1.172 46.300 0.565 0.917 Jul1998 134.8 1.180 45.000 0.549 0.915 Aug1998 135.2 1.184 44.000 0.537 0.912 Sep1998 135.2 1.184 48.300 0.589 0.934 Oct1998 130.4 1.142 47.400 0.578 0.905 Nov1998 127.6 1.117 46.200 0.563 0.885 Dec1998 126.6 1.109 38.800 0.473 0.842 Jan1999 126.1 1.104 40.900 0.499 0.850 Feb1999 125.5 1.099 38.200 0.466 0.833 Mar1999 125.5 1.099 42.800 0.522 0.857 Apr1999 125.2 1.096 52.500 0.640 0.905 May1999 127.4 1.116 52.600 0.641 0.916 Jun1999 131.6 1.152 52.400 0.639 0.937 Jul1999 133.9 1.173 58.700 0.716 0.981 Aug1999 133.9 1.173 63.000 0.768 1.003 Sep1999 134.1 1.174 67.600 0.824 1.027 Oct1999 129.5 1.134 65.500 0.799 0.993 Nov1999 127.5 1.116 71.300 0.870 1.013 Dec1999 126.5 1.108 72.900 0.889 1.016 Jan2000 126.8 1.110 75.300 0.918 1.030 Feb2000 126.7 1.109 87.900 1.072 1.094 Mar2000 126.7 1.109 89.700 1.094 1.103 Apr2000 126.8 1.110 83.100 1.013 1.070 May2000 128.6 1.126 82.900 1.011 1.078 Jun2000 133.6 1.170 86.200 1.051 1.120 Jul2000 136.2 1.193 88.700 1.082 1.146 Page9of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Aug2000 137.4 1.203 91.600 1.117 1.167 Sep2000 137.8 1.207 110.100 1.343 1.264 Oct2000 134.1 1.174 108.600 1.324 1.237 Nov2000 130.9 1.146 108.400 1.322 1.220 Dec2000 132.7 1.162 100.600 1.227 1.189 Jan2001 136.4 1.194 96.100 1.172 1.185 Feb2001 136.4 1.194 91.600 1.117 1.162 Mar2001 136.5 1.195 83.100 1.013 1.119 Apr2001 135.1 1.183 86.200 1.051 1.128 May2001 136.2 1.193 94.200 1.149 1.174 Jun2001 148.4 1.299 90.200 1.100 1.216 Jul2001 149.5 1.309 81.300 0.991 1.176 Aug2001 148.9 1.304 83.200 1.015 1.182 Sep2001 148.2 1.298 93.000 1.134 1.229 Oct2001 143.8 1.259 76.800 0.937 1.124 Nov2001 137.3 1.202 70.500 0.860 1.058 Dec2001 136.9 1.199 56.600 0.690 0.985 Jan2002 136.3 1.194 58.300 0.711 0.991 Feb2002 135.4 1.186 59.600 0.727 0.993 Mar2002 135.7 1.188 69.100 0.843 1.043 Apr2002 135.4 1.186 76.400 0.932 1.079 May2002 137.9 1.208 75.000 0.915 1.085 Jun2002 143.6 1.257 71.400 0.871 1.095 Jul2002 144.9 1.269 75.500 0.921 1.123 Aug2002 145.0 1.270 77.900 0.950 1.135 Sep2002 145.8 1.277 89.500 1.091 1.199 Oct2002 140.0 1.226 95.100 1.160 1.198 Nov2002 139.5 1.222 82.800 1.010 1.133 Dec2002 139.6 1.222 84.600 1.032 1.142 Jan2003 140.3 1.229 95.700 1.167 1.203 Feb2003 140.6 1.231 120.400 1.468 1.331 Mar2003 143.3 1.255 128.900 1.572 1.388 Apr2003 144.3 1.264 98.300 1.199 1.236 May2003 145.1 1.271 85.500 1.043 1.175 Jun2003 148.3 1.299 87.200 1.063 1.200 Jul2003 151.6 1.327 90.100 1.099 1.231 Aug2003 151.3 1.325 94.100 1.148 1.250 Sep2003 152.0 1.331 88.200 1.076 1.224 Oct2003 147.4 1.291 97.800 1.193 1.250 Nov2003 142.7 1.250 93.000 1.134 1.201 Dec2003 142.9 1.251 95.800 1.168 1.216 Jan2004 143.1 1.253 106.800 1.302 1.274 Feb2004 143.1 1.253 100.800 1.229 1.243 Mar2004 143.1 1.253 107.800 1.315 1.279 Page10of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Apr2004 143.1 1.253 115.200 1.405 1.317 May2004 144.2 1.263 116.000 1.415 1.327 Jun2004 152.4 1.335 111.500 1.360 1.345 Jul2004 152.2 1.333 119.300 1.455 1.384 Aug2004 154.0 1.349 131.100 1.599 1.454 Sep2004 154.0 1.349 136.800 1.668 1.483 Oct2004 145.8 1.277 161.700 1.972 1.569 Nov2004 144.9 1.269 153.600 1.873 1.523 Dec2004 146.2 1.280 133.800 1.632 1.428 Jan2005 148.9 1.304 138.500 1.689 1.466 Feb2005 148.0 1.296 146.000 1.780 1.499 Mar2005 148.1 1.297 169.400 2.066 1.620 Apr2005 148.7 1.302 170.900 2.084 1.631 May2005 151.1 1.323 165.300 2.016 1.614 Jun2005 159.7 1.398 180.600 2.202 1.736 Jul2005 162.1 1.419 186.200 2.271 1.777 Aug2005 162.5 1.423 194.500 2.372 1.822 Sep2005 162.8 1.426 209.900 2.560 1.902 Oct2005 159.5 1.397 252.000 3.073 2.101 Nov2005 161.1 1.411 199.100 2.428 1.838 Dec2005 161.4 1.413 193.600 2.361 1.811 Jan2006 167.0 1.462 191.800 2.339 1.831 Feb2006 168.6 1.476 190.000 2.317 1.829 Mar2006 167.4 1.466 199.200 2.429 1.870 Apr2006 169.6 1.485 221.900 2.706 1.998 May2006 170.8 1.496 231.400 2.822 2.053 Jun2006 181.2 1.587 238.100 2.904 2.140 Jul2006 181.9 1.593 231.600 2.824 2.110 Aug2006 180.2 1.578 241.400 2.944 2.152 Sep2006 181.0 1.585 203.100 2.477 1.960 Oct2006 171.2 1.499 198.100 2.416 1.884 Nov2006 167.2 1.464 198.200 2.417 1.864 Dec2006 167.8 1.469 200.400 2.444 1.879 Jan2007 171.9 1.505 180.000 2.195 1.795 Feb2007 175.7 1.539 191.500 2.335 1.873 Mar2007 172.1 1.507 215.100 2.623 1.976 Apr2007 173.1 1.516 231.800 2.827 2.066 May2007 179.2 1.569 225.300 2.748 2.064 Jun2007 186.7 1.635 222.400 2.712 2.087 Jul2007 187.0 1.637 237.800 2.900 2.168 Aug2007 187.6 1.643 225.500 2.750 2.108 Sep2007 188.4 1.650 238.900 2.913 2.180 Oct2007 182.7 1.600 243.300 2.967 2.174 Nov2007 180.3 1.579 288.200 3.515 2.392 Page11of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Dec2007 180.0 1.576 266.700 3.252 2.280 Jan2008 181.9 1.593 273.800 3.339 2.326 Feb2008 180.0 1.576 280.200 3.417 2.349 Mar2008 183.1 1.603 339.600 4.141 2.669 Apr2008 185.2 1.622 352.500 4.299 2.746 May2008 189.5 1.659 384.900 4.694 2.934 Jun2008 191.9 1.680 410.500 5.006 3.077 Jul2008 196.1 1.717 423.800 5.168 3.167 Aug2008 197.1 1.726 343.900 4.194 2.762 Sep2008 195.9 1.715 335.100 4.087 2.711 Oct2008 193.0 1.690 279.000 3.402 2.409 Nov2008 187.7 1.644 218.200 2.661 2.071 Dec2008 188.3 1.649 163.000 1.988 1.791 Jan2009 190.3 1.666 159.800 1.949 1.785 Feb2009 190.3 1.666 145.600 1.776 1.712 Mar2009 187.6 1.643 136.800 1.668 1.653 Apr2009 186.9 1.637 159.900 1.950 1.768 May2009 190.5 1.668 158.600 1.934 1.780 Jun2009 193.3 1.693 183.700 2.240 1.923 Jul2009 196.2 1.718 165.200 2.015 1.843 Aug2009 194.7 1.705 196.100 2.391 1.993 Sep2009 194.9 1.707 186.600 2.276 1.946 Oct2009 189.9 1.663 193.300 2.357 1.955 Nov2009 186.0 1.629 207.800 2.534 2.009 Dec2009 186.0 1.629 197.500 2.409 1.956 Jan2010 186.3 1.631 220.700 2.691 2.077 Feb2010 186.1 1.630 200.200 2.441 1.971 Mar2010 189.0 1.655 217.000 2.646 2.071 Apr2010 188.8 1.653 231.500 2.823 2.145 May2010 192.0 1.681 226.000 2.756 2.133 Jun2010 197.8 1.732 212.400 2.590 2.092 Jul2010 199.8 1.750 209.300 2.552 2.087 Aug2010 200.8 1.758 221.400 2.700 2.154 Sep2010 200.0 1.751 220.000 2.683 2.143 Oct2010 194.6 1.704 235.800 2.876 2.196 Nov2010 190.9 1.672 245.300 2.991 2.226 Dec2010 191.4 1.676 250.000 3.049 2.253 Jan2011 193.1 1.691 260.400 3.176 2.314 Feb2011 194.4 1.702 278.800 3.400 2.415 Mar2011 195.0 1.708 307.500 3.750 2.565 Apr2011 194.1 1.700 325.100 3.965 2.651 May2011 196.9 1.724 315.100 3.843 2.614 Jun2011 205.7 1.801 316.900 3.865 2.668 Jul2011 215.3 1.885 311.500 3.799 2.689 Page12of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Aug2011 216.6 1.897 296.900 3.621 2.621 Sep2011 215.8 1.890 306.500 3.738 2.666 Oct2011 206.6 1.809 299.600 3.654 2.584 Nov2011 204.0 1.786 322.700 3.935 2.689 Dec2011 204.4 1.790 301.000 3.671 2.580 Jan2012 201.1 1.761 308.800 3.766 2.603 Feb2012 200.3 1.754 316.500 3.860 2.638 Mar2012 199.8 1.750 330.800 4.034 2.709 Apr2012 198.1 1.735 327.100 3.989 2.682 May2012 201.5 1.764 315.600 3.849 2.640 Jun2012 207.7 1.819 284.600 3.471 2.513 Jul2012 221.5 1.940 287.900 3.511 2.600 Aug2012 222.1 1.945 313.400 3.822 2.733 Sep2012 222.8 1.951 330.400 4.029 2.824 Oct2012 214.1 1.875 334.100 4.074 2.799 Nov2012 212.3 1.859 311.600 3.800 2.674 Dec2012 213.8 1.872 303.300 3.699 2.639 Jan2013 199.2 1.744 303.600 3.702 2.567 Feb2013 199.4 1.746 327.700 3.996 2.691 Mar2013 199.0 1.743 308.700 3.765 2.592 Apr2013 198.8 1.741 303.900 3.706 2.566 May2013 203.5 1.782 296.400 3.615 2.552 Jun2013 211.9 1.856 294.900 3.596 2.587 Jul2013 211.4 1.851 300.400 3.663 2.612 Aug2013 210.4 1.842 307.400 3.749 2.643 Sep2013 210.3 1.842 315.300 3.845 2.683 Oct2013 201.2 1.762 306.800 3.741 2.593 Nov2013 199.0 1.743 295.300 3.601 2.523 Dec2013 200.5 1.756 302.900 3.694 2.570 Jan2014 215.1 1.884 297.500 3.628 2.616 Feb2014 214.4 1.877 309.100 3.770 2.672 Mar2014 214.8 1.881 306.500 3.738 2.661 Apr2014 210.8 1.846 306.700 3.740 2.642 May2014 215.2 1.884 304.400 3.712 2.652 Jun2014 224.0 1.961 296.500 3.616 2.656 Jul2014 227.5 1.992 295.300 3.601 2.668 Aug2014 227.7 1.994 293.900 3.584 2.662 Sep2014 225.1 1.971 291.000 3.549 2.634 Oct2014 217.0 1.900 271.400 3.310 2.492 Nov2014 210.7 1.845 260.900 3.182 2.406 Dec2014 213.9 1.873 218.900 2.670 2.208 Jan2015 222.4 1.947 173.600 2.117 2.019 Feb2015 221.1 1.936 184.300 2.248 2.067 Mar2015 218.2 1.911 185.700 2.265 2.059 Page13of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Apr2015 213.3 1.868 178.200 2.173 1.996 May2015 217.0 1.900 196.600 2.398 2.109 Jun2015 237.2 2.077 193.400 2.359 2.195 Jul2015 237.3 2.078 187.000 2.280 2.163 Aug2015 236.8 2.074 180.400 2.200 2.127 Sep2015 234.2 2.051 163.100 1.989 2.025 Oct2015 218.2 1.911 165.300 2.016 1.955 Nov2015 213.4 1.869 159.700 1.948 1.902 Dec2015 214.8 1.881 131.100 1.599 1.762 Jan2016 205.3 1.798 114.400 1.395 1.629 Feb2016 204.3 1.789 107.700 1.313 1.589 Mar2016 204.5 1.791 113.800 1.388 1.621 Apr2016 202.4 1.772 116.800 1.424 1.626 May2016 206.3 1.806 137.800 1.680 1.754 Jun2016 220.4 1.930 149.400 1.822 1.885 Jul2016 226.2 1.981 152.200 1.856 1.928 Aug2016 227.3 1.990 143.500 1.750 1.889 Sep2016 228.1 1.997 155.500 1.896 1.955 Oct2016 214.9 1.882 153.400 1.871 1.877 Nov2016 211.3 1.850 152.900 1.865 1.856 Dec2016 211.7 1.854 153.300 1.870 1.860 Jan2017 231.8 2.030 158.000 1.927 1.987 Feb2017 232.9 2.039 159.700 1.948 2.001 Mar2017 234.2 2.051 158.000 1.927 1.999 Apr2017 234.3 2.052 157.900 1.926 1.999 May2017 237.1 2.076 165.300 2.016 2.051 Jun2017 251.0 2.198 163.100 1.989 2.110 Jul2017 253.4 2.219 169.100 2.062 2.153 Aug2017 251.2 2.200 179.000 2.183 2.193 Sep2017 249.0 2.180 192.500 2.348 2.251 Oct2017 238.7 2.090 202.900 2.474 2.252 Nov2017 236.8 2.074 211.200 2.576 2.284 Dec2017 237.4 2.079 212.700 2.594 2.295 Jan2018 243.4 2.131 218.000 2.659 2.353 Feb2018 245.3 2.148 216.600 2.641 2.355 Mar2018 241.0 2.110 214.000 2.610 2.320 Apr2018 237.7 2.081 220.500 2.689 2.337 May2018 241.3 2.113 238.800 2.912 2.449 Jun2018 255.2 2.235 248.900 3.035 2.571 Jul2018 258.8 2.266 244.200 2.978 2.565 Aug2018 258.7 2.265 242.000 2.951 2.553 Sep2018 255.4 2.236 249.800 3.046 2.577 Oct2018 246.6 2.159 258.400 3.151 2.576 Nov2018 240.2 2.103 252.600 3.080 2.514 Page14of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Dec2018 241.0 2.110 221.500 2.701 2.359 Jan2019 244.9 2.144 191.600 2.337 2.225 Feb2019 244.0 2.137 207.800 2.534 2.304 Mar2019 241.6 2.116 227.300 2.772 2.391 Apr2019 238.7 2.090 226.200 2.759 2.371 May2019 241.1 2.111 224.400 2.737 2.374 Jun2019 250.7 2.195 197.000 2.402 2.282 Jul2019 253.3 2.218 209.400 2.554 2.359 Aug2019 257.1 2.251 198.500 2.421 2.322 Sep2019 254.4 2.228 208.000 2.537 2.357 Oct2019 231.4 2.026 210.600 2.568 2.254 Nov2019 230.2 2.016 212.700 2.594 2.259 Dec2019 232.5 2.036 219.500 2.677 2.305 Jan2020 232.9 2.039 205.400 2.505 2.235 Feb2020 234.3 2.052 184.000 2.244 2.132 Mar2020 233.2 2.042 160.400 1.956 2.006 Apr2020 233.0 2.040 116.100 1.416 1.778 May2020 232.8 2.039 101.800 1.241 1.704 Jun2020 250.4 2.193 130.100 1.587 1.938 Jul2020 253.5 2.220 168.600 2.056 2.151 Aug2020 253.6 2.221 178.200 2.173 2.201 Sep2020 256.2 2.243 165.700 2.021 2.150 Oct2020 236.5 2.071 174.200 2.124 2.093 Nov2020 233.3 2.043 187.000 2.280 2.143 Dec2020 232.8 2.039 209.400 2.554 2.255 Jan2021 234.7 2.055 217.600 2.654 2.307 Feb2021 235.3 2.060 247.000 3.012 2.460 Mar2021 253.2 2.217 282.500 3.445 2.733 Apr2021 237.1 2.076 263.400 3.212 2.553 May2021 239.2 2.095 296.700 3.618 2.735 Jun2021 259.8 2.275 296.800 3.620 2.840 Jul2021 264.727 2.318 305.392 3.724 2.909 Aug2021 266.382 2.333 300.698 3.667 2.893 Sep2021 263.224 2.305 311.738 3.802 2.934 Oct2021 255.289 2.235 349.598 4.263 3.087 Nov2021 253.517 2.220 343.086 4.184 3.045 Dec2021 251.385 2.201 323.329 3.943 2.933 Jan2022 263.262 2.305 342.535 4.177 3.092 Feb2022 269.233 2.358 389.425 4.749 3.362 Mar2022 264.930 2.320 472.872 5.767 3.768 Apr2022 262.970 2.303 497.370 6.065 3.883 May2022 267.786 2.345 551.997 6.732 4.187 Jun2022 284.453 2.491 622.389 7.590 4.633 Jul2022 297.134 2.602 531.451 6.481 4.231 Page15of18 to ULNRC06798 EnergyAdjustmentFactor(Ex)Derivation Ex=Px(PxCoefficient)+Fx(FxCoefficient) 0.58 =PxCoefficient(ForPWR) 0.42 =FxCoefficient(ForPWR)
Preliminary Px Fx IndexDate WPU0543 WPU0573 Ex MINIMUMDECOMMISSIONINGCOSTPER10CFR50.75FORMULAPROCESS Aug2022 300.917 2.635 466.971 5.695 3.920 Sep2022 304.327 2.665 512.191 6.246 4.169 Oct2022 285.264 2.498 565.417 6.895 4.345 Nov2022 274.040 2.400 544.954 6.646 4.183 Dec2022 279.934 2.451 394.700 4.813 3.443 Producer Price Index-Commodities Producer Price Index-Commodities Original Data Value Original Data Value Px Values Fx Values Series Id:
WPU0543 Series Id:
WPU0573 Not Seasonally Adjusted Not Seasonally Adjusted Group:
Fuels and related products and power Group:
Fuels and related products and power Item:
Industrial electric power Item:
Light fuel oils Base Date:
198200 Base Date:
198200 Page16of18 to ULNRC06798 Bx 1986 1.000 1987 1.000 1988 2.007 1989 2.007 1990 2.007 1991 2.494 1992 2.494 1993 11.408 1994 11.873 1995 12.824 1996 12.771 1997 15.852 1998 15.886 1999 15.886 2000 8.052 2001 8.052 2002 9.467 2003 9.467 2004 7.934 2005 7.934 2006 8.683 2007 8.683 2008 9.872 2009 9.872 2010 12.280 2011 12.280 2012 12.280 2013 13.885 2014 13.885 2015 13.885 NUREG1307Rev15;FinalReport;PublishedJanuary2013 BxValuesforGenericLLWDisposalSite(e)
CombinationofCompactAffiliatedandNonCompactFacility(f,g)
PWR NUREG1307Rev14;PublishedNovember2010 BxValuesforGenericLLWDisposalSite(e)
DirectDisposalwithVendors(f)
PWR WasteBurialAdjustmentFactor(Bx)Determination MINIMUMDECOMMISSIONINGCOST PER10CFR50.75FORMULAPROCESS Page17of18 to ULNRC06798 Bx WasteBurialAdjustmentFactor(Bx)Determination MINIMUMDECOMMISSIONINGCOST PER10CFR50.75FORMULAPROCESS 2016 12.471 2017 12.471 2018 12.853 NUREG1307Rev17;FinalReport;PublishedFebruary2019 BxValuesforGeneratorsLocatedintheUnaffiliatedStatesandthoseLocatedinCompactAffiliatedStateshaving noDisposalFacility(c)
PWR 2019 12.853 2020 12.793 NUREG1307Rev18;FinalReport;PublishedJanuary2021 BxValuesforGeneratorsLocatedintheUnaffiliatedStatesandthoseLocatedinCompactAffiliatedStateshaving noDisposalFacility(c)
PWR 2021 12.793 2022 13.711 NUREG1307Rev19;FinalReport;PublishedFebruary2023 BxValuesforGeneratorsLocatedintheUnaffiliatedStatesandthoseLocatedinCompactAffiliatedStateshaving noDisposalFacility(c)
PWR NUREG1307Rev16;FinalReport;PublishedMarch2017 BxValuesforGeneratorsLocatedintheUnaffiliatedStatesandthoseLocatedinCompactAffiliatedStateshaving noDisposalFacility(c)
PWR NUREG1307,Rev.19,Page6,Paragraph1states:
LicenseesnotlocatedintheNorthwest,RockyMountain,Atlantic,orTexasCompactsshouldusetheBx valuesforGeneratorsLocatedinStates NotAffiliatedwithaCompacthavingaDisposalFacility(seefootnote(c)inTable21).
Footnote(c)toTable2.1,"ValuesofBx asaFunctionofLLWBurialSiteandYear(a)"states:
EffectivewithNUREG1307,Revision16,theCWFinAndrewsCounty,Texas,isalsoavailableasafullservice(i.e.,ClassA,B, andC)LLW disposalfacilityforwastegeneratorslocatedinStatesnotaffiliatedwiththeTexasCompact.Outofcompactgenerators,however,must submitanimportpetitiontotheTexasCompactCommissionforapprovalpriortoshipping.TheStateofTexasalsolimitstotalnoncompact wastedisposedattheCWFto30percentoflicensedcapacityandimposesadditionalfeesonLLWdisposedoffromoutofcompactgenerators.
WiththeavailabilityofthisfullservicedisposalfacilitytooutofcompactwastegeneratorsandtheClive,UtahdisposalfacilityforanyClassA LLWgeneratedintheU.S.,theGenericLLWDisposalSitescenariousedinpreviousversionsofNUREG1307isreplacedwiththisscenario,which providesBx valuesrepresentingacompositeofthedisposalratesforthesetwodisposalfacilities.TheseBx factorsarerecommendedforusefor plantsthatcurrentlyhavenodisposalsiteavailablewithintheirdesignatedLLWCompact.
Page18of18