Summary of March 7, 2023, Meeting with Nextera Energy Seabrook, LLC Regarding Planned Submittal of License Amendment Request to Revise Emergency Action Level Due to Modification to Containment Fire Detection Equipment
ML23086B996
Person / Time
Site: Seabrook 
Issue date: 04/04/2023
From: Justin Poole
Plant Licensing Branch 1
To:
NextEra Energy Seabrook
Poole J, NRR/DORL/LPLI, 415-2048
Shared Package
ML23086C006 List:
References
EPID L-2023-LRM-0013
Download: ML23086B996 (1)


Text

April 4, 2023 LICENSEE:

NEXTERA ENERGY SEABROOK, LLC FACILITIES: SEABROOK STATION, UNIT NO. 1

SUBJECT:

SUMMARY

OF MARCH 7, 2023, MEETING WITH NEXTERA ENERGY SEABROOK, LLC REGARDING PLANNED SUBMITTAL OF LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY ACTION LEVEL DUE TO MODIFICATION TO CONTAINMENT FIRE DETECTION EQUIPMENT (EPID L-2023-LRM-0013)

On March 7, 2023, an Observation public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of NextEra Energy Seabrook, LLC (the licensee) via webinar. The purpose of the meeting was to discuss the licensees plan to submit a license amendment request to revise the Seabrook Station, Unit. No. 1 emergency action level (EAL) due to a modification to the containment fire detection equipment scheduled for implementation in the fall 2024 refueling outage. The meeting notice and agenda, dated February 22, 2023, is available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML23053A145. A list of attendees is provided as an Enclosure.

The licensees slide presentation is available in ADAMS at Accession No. ML23066A247. In the meeting, the licensee discussed how they intend to submit a license amendment request for Seabrook to update an EAL to account for a planned modification in the containment building fire detector system. Specifically, the licensee stated that the amendment would be looking to continue the exception in EAL HU4(2) but for a single detector, rather than a zone, and that the exception would be applicable for all Modes instead of just Modes 1 and 2, as is currently approved. The licensee said that the current containment building fire detection system has 9 zones, comprised of 137 ionization smoke detectors. The new system will have 120 photoelectric smoke detectors outside the bio-shield wall and two linear heat detection cables inside the bio-shield wall with an upgraded alarm panel provided in the control room. The licensee stated that they planned to submit the amendment by July 2023. The NRC staff asked a few clarifying questions and reminded the licensee to provide clear justification for the changes being proposed.

A member of the public was in attendance. No Public Meeting Feedback Forms were received.

Please direct any inquiries to me at 301-415-2048, or via email at Justin.Poole@nrc.gov.

/RA James Kim for/

Justin C. Poole, Project Manager Plant Licensing Branch I Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-443

Enclosure:

List of Attendees cc: Listserv

Enclosure LIST OF ATTENDEES MARCH 7, 2023, MEETING WITH NEXTERA ENERGY SEABROOK LLC PROPOSED EAL CHANGE LICENSE AMENDMENT REQUEST NRC

Participants:

Justin Poole, Project Manager Raymond Hoffman, Emergency Preparedness Specialist Keith Miller, Emergency Preparedness Specialist Jeffrey Herrera, Emergency Preparedness Specialist Neil Sheehan, Public Affairs Officer NextEra Energy/FPL

Participants:

Kenneth Mack, Fleet Licensing Manager Jerry Phillabaum, Principle Engineer David Currier, Emergency Preparedness Manager Michael Finnegan, Emergency Preparedness Senior Analyst Patricia Furio, Enercon Rolando Robelin, Enercon Brian Fox, Enercon Jeffrey Quinn, EPM Aram, Kayserian, EPM Public:

Sarah Abramson, C-10

Package: ML23086C006 Meeting Slides: ML23066A247 Meeting Notice: ML23053A145 Meeting Summary: ML23086B996 OFFICE NRR/DORL/LPL1/PM NRR/DORL/LPL1/LA NRR/DORL/LPL1/BC NRR/DORL/LPL1/PM NAME JPoole KZeleznock HGonzález JPoole (JKim for)

DATE 03/27/2023 04/04/2023 04/04/2023 04/04/2023