March 28, 2023 LICENSEE:

Florida Power and Light/NextEra FACILITIES: Turkey Point Nuclear Generating Unit Nos. 3 and 4

SUBJECT:

SUMMARY

OF DECEMBER 7, 2022, MEETING WITH FLORIDA POWER AND LIGHT/NEXTERA TO DISCUSS A TURKEY POINT PLANNED LICENSE AMENDMENT REQUEST TO TRANSITION TO A 24-MONTH FUEL CYCLE (EPID NO. L-2022-LRM-0096)

On December 7, 2022, a virtual observation public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Florida Power and Light/NextEra (FPL, the licensee). The purpose of the meeting was to discuss a planned license amendment requests (LAR) for Turkey Point Nuclear Generating Unit Nos. 3 and 4 (Turkey Point) to transition to a 24-month fuel cycle. The licensee also plans to submit another planned LAR which modifies the spent fuel pool criticality analysis in support of transition to a 24-month fuel cycle. The meeting notice and agenda, dated November 17, 2022, are available in the Agencywide Documents Access and Management System (ADAMS) Accession No. ML22326A034. A list of attendees is provided in the enclosure.

The licensee presented (ML22336A026) and discussed the following:

Objectives of the LARs o Scope and Schedule.

o Contents of each LAR.

o Licensee requested approval timeline.

Completed Licensing Actions (to support the transition to 24-months), which include:

o License Amendments 296 and 286 (ML22028A064) which approves adoption of Full Spectrum Loss-Of-Coolant Accident (FSLOCA).

o Requirements of NRC Generic Letter (GL) 91-04:

License Amendments 263 and 258 (ML15166A320) which approves adoption of the Surveillance Frequency Control Program (Technical Specification Task Force (TSTF)-425.

License Amendments 295 and 288 (ML21119A355) which approves adoption of Containment Leak Rate Frequency Extension in accordance with Nuclear Energy Institute (NEI) 94-01, Revision 3A.

Revised Frequencies for Steam Generator Tube Inspections in accordance with TSTF-577. This request is currently under review by the NRC staff, as part of the Improved Standard Technical Specifications (ITS) conversion.

Proposed Licensing Actions and Schedules:

o Spent Fuel Pool Criticality LAR:

Incorporates fuel management changes.

Updated to fully comply with latest guidance.

o Transition to 24-Month Fuel Cycle LAR:

Fuel design change technical justifications.

Nuclear Steam Supply System (NSSS) and Balance of Plant (BOP) analyses updates.

Instrument drift (in accordance with GL 91-04).

Technical Specifications (TS), TS Bases and Core Operating Limit Report (COLR) markups.

o Exemption for use of AXIOM Cladding.

Methodology and Approach:

o ADOPT Fuel Introduction Use of WCAP-18482-P.

o AXIOM Cladding:

Use of WCAP-18546-P.

Use of AXIOM cladding requires an exemption from 10 CRF 50.46.

o FSLOCA Re-analysis:

Approved May 2022 for Turkey Point.

o Non-LOCA Re-analysis:

No changes to analysis models or methods, except Rod Ejection.

Majority of Non-LOCA event to be reanalyzed.

o Spent Fuel Pool Criticality Analysis:

Incorporate fuel management changes as result of 24-month cycle:

Burnable absorbers.

Soluble boron during depletion.

Axial profiles.

Other fuel design input, such as fuel density.

Use of NEI-12-16, Revision 4, as endorsed by RG 1.240.

There were three members of the public in attendance. They had no questions or feedback.

Please direct any inquiries to me at 301-415-3867, or Michael.Mahoney@nrc.gov.

Sincerely,

/RA/

Michael Mahoney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-250 and 50-251

Enclosure:

List of Attendees cc: Listserv

Enclosure LIST OF ATTENDEES DECEMBER 7, 2022, PUBLIC MEETING WITH FLORIDA POWER AND LIGHT/NEXTERA TURKEY POINT NUCLEAR GENERATING UNITS NOS. 3 AND 4 PLANNED LICENSE AMENDMENT REQUEST RELATED TO THE TRANSITION TO A 24-MONTH FUEL CYCLE Name Organization Michael Mahoney U.S. Nuclear Regulatory Commission (NRC)

Santosh Bhatt NRC Charley Peabody NRC Mathew Panicker NRC Steve Catron Florida Power and Light Company (FPL)

Kenneth Mack FPL Jarrett Mack FPL Emilio Fuentes FPL Patrick Han FPL Philip Tiemann FPL Rob Regan FPL James Smith Westinghouse Electric Company (Westhinghouse)

Michael Wenner Westinghouse Kevin Barber Westinghouse Peter Hilton Westinghouse Michael Watson Westinghouse Guirong Pan Westinghouse Lucas Burkett Westinghouse Christopher Trelaeani Westinghouse Bill Hickey Westinghouse Mary Catherine Hancock Westinghouse Phil Couture Westinghouse William Higby Westinghouse Steve Kane Westinghouse Bob Clark Westinghouse DL Williams Westinghouse Matthew Marzano Public - Senate EPW Phil Opsal Public - Framatome Ron Jarrett Public - Framatome

Package: ML23081A081 Meeting Notice: ML22326A034 Meeting Summary: ML23081A502 OFFICE NRR/DORL/LPL2-2/PM NRR/DORL/LPL2-2/LA NRR/DORL/LPL2-2/BC NAME MMahoney RButler DWrona DATE 03/21/2023 03/27/2023 03/27/2023