UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Don Shaw Licensing Manager TN Americas LLC 7160 Riverwood Drive Suite 200 Columbia, MD 21046
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. TN-40 PACKAGE
Dear Don Shaw:
By letter dated December 16, 2021 (Agencywide Documents Access and Management System Package Accession No [ADAMS] ML21350A282), TN Americas LLC submitted an amendment request for Revision No. 4 to Certificate of Compliance No. 9313 for the Model No. TN-40 package. The staff accepted your application, with Observations, for a detailed technical review on June 15, 2022 (ADAMS No. ML22164A321)
In connection with our review, we need the information identified in the enclosure to this letter.
We request that you provide this information by July 10, 2023. If you are unable to meet this deadline, you must notify us in writing no later than July 1, 2023, of your submittal date and the reasons for the delay. The staff will then assess the impact of the new submittal date and notify you of a revised schedule.
Please reference Docket No. 71-9313 and Enterprise Project Identifier (EPID) No. L-2021-LLA-0086 in future correspondence related to this request.
Sincerely, Pierre M. Saverot, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9313 EPID L-2021-LLA-0086
Enclosure:
Request for Additional Information February 9, 2023 Signed by Saverot, Pierre on 02/09/23
D. Shaw
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. TN-40 PACKAGE, DOCUMENT DATE:
DISTRIBUTION:
71sf9313all@listmgr.nrc.gov SHelton, NMSS ADimitriadis, RI BDesai, RII DHills, RIII GWarnick, RIV ADAMS Package No. ML23037A100(Pkg) ML23037A102 (Ltr) ML23037A103(RAI)
OFC:
NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME:
PSaverot YKim JHuang TBoyce JGoodridge DATE:
02/06/2023 02/07/2023 02/07/2023 02/08/2023 02/09/2023 OFC:
NMSS/DFM NAME:
YDiaz-Sanabria DATE:
02/09/2023 OFFICIAL RECORD COPY February 9, 2023
ML23037A100; Ltr ML23037A102 OFFICE NMSS/DFM/STLB NSIR/DPR NMSS/DFM/STLB NAME PSaverot JGoodridge PSaverot DATE Feb 6, 2023 Feb 9, 2023 Feb 9, 2023