ND-22-0600, ITAAC Closure Notification on Completion of ITAAC 2.3.02.05.i (Index Number 291)

From kanterella
(Redirected from ML22350A723)
Jump to navigation Jump to search

ITAAC Closure Notification on Completion of ITAAC 2.3.02.05.i (Index Number 291)
ML22350A723
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 12/16/2022
From: Coleman J
Southern Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
ND-22-0600, ITAAC 2.3.02.05.i
Download: ML22350A723 (1)


Text

Jamie M. Coleman 7825 River Road Regulatot7 Affairs Director Waynesboro, GA 30830

^ Southern Nuclear Voglle 3 & 4 706-848-6926 tel

December 16, 2022

Docket No.: 52-026

ND-22-0600 10 CFR 52.99(c)(1)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Southern Nuclear Operating Company Vogtie Electric Generating Plant Unit 4 ITAAC Closure Notification on Completion of ITAAC 2.3.02.05.i [Index Number 2911

Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) ohhe completion of Vogtie Electric Generating Plant (VEGP)

Unit 4 Inspections. Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.3.02.05.1 [Index Number 291] to demonstrate that the Chemical and Volume Control System (CVS) equipment identified as seismic Category I or Class IE in the Combined License (COL) Appendix C, Table 2.3.2-1 is designed and constructed in accordance with applicable requirements.

The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEl) 08-01, "Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted

Jamte M. Coleman Regulatory Affairs Director Vogtie 3 & 4

Enclosure:

Vogtie Electric Generating Plant (VEGP) Unit 4 Completion of ITAAC 2.3.02.05.i [Index Number 291]

JMC/AD/sfr U.S. Nuclear Regulatory Commission ND-22-0600 Page 2 of 2

cc: Regional Administrator, Region II Director, Office of Nuclear Reactor Regulation (NRR)

Director. Vogtle Project Office NRR Senior Resident Inspector - Vogtle 3 & 4 U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 1 of 9

Southern Nuclear Operating Company ND-22-0600 Enclosure

Vogtie Electric Generating Plant (VEGP) Unit 4 Completion of ITAAC 2.3.02.05.i [Index Number 291]

U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 2 of 9

ITAAC Statement

Design Commitment

5. The seismic Category I equipment identified in Table 2.3.2-1 can withstand seismic design basis loads without loss of safety function.

6.a) The Class 1E equipment identified in Table 2.3.2-1 as being qualified for a harsh environment can withstand the environmental conditions that would exist before, during, and following a design basis accident without loss of safety function for the time required to perform the safety function.

Inspections. Tests. Analyses

i) Inspection will be performed to verify that the seismic Category I equipment identified in Table 2.3.2-1 is located on the Nuclear Island.

ii) Type tests, analyses, or a combination of type tests and analyses of seismic Category I equipment will be performed.

iii) Inspection will be performed for the existence of a report verifying that the as-built equipment including anchorage is seismically bounded by the tested or analyzed conditions.

i) Type tests, analyses, or a combination of type tests and analyses will be performed on Class 1E equipment located in a harsh environment.

ii) Inspection will be performed of the as-bullt Class IE equipment and the associated wiring, cables, and terminations located in a harsh environment.

Acceptance Criteria

i) The seismic Category I equipment identified in Table 2.3.2-1 is located on the Nuclear Island.

ii) A report exists and concludes that the seismic Category I equipment can withstand seismic design basis dynamic loads without loss of safety function.

iii) A report exists and concludes that the as-built equipment including anchorage is seismically bounded by the tested or analyzed conditions.

I) A report exists and concludes that the Class 1E equipment identified in Table 2.3.2-1 as being qualified for a harsh environment can withstand the environmental conditions that would exist before, during, and following a design basis accident without loss of safety function for the time required to perform the safety function.

ii) A report exists and concludes that the as-built Class 1E equipment and the associated wiring cables, and terminations identified in Table 2.3.2-1 as being qualified for a harsh environment are bounded by type tests, analyses, or a combination of type tests and analyses.

U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 3 of 9

ITAAC Determination Basis

This ITAAC requires that inspections, tests, and analyses be performed and documented to ensure the Chemical and Volume Control System (CVS) equipment identified as seismic Category I or Class 1E in the Combined License (COL) Appendix C, Table 2.3.2-1 (the Table) is designed and constructed in accordance with applicable requirements.

\\) The seismic Category I equipment identified in Table 2.3.2-1 is located on the Nuclear Island.

To assure that seismic Category I equipment can withstand seismic design basis loads without loss of safety function, all the equipment in the Table is designed to be located on the seismic Category I Nuclear Island. In accordance with Equipment Qualification (EQ) ITAAC As-built Walkdown Guideline and the EQ ITAAC As-built Installation Documentation Guideline (References 1 and 2), an inspection was conducted of the CVS to confirm the satisfactory installation of the seismically qualified equipment. The inspection includes verification of equipment make/model/serial number and verification of equipment location (Building, Elevation, Room). The EQ As-Built Reconciliation Report (EQRR) (Reference 3) identified in Attachment A documents the results of the inspection and concludes that the seismic Category I equipment is located on the Nuclear Island.

ii) A report exists and concludes that the seismic Category I equipment can withstand seismic design basis dynamic loads without loss of safety function.

Seismic Category I equipment in the Table requires type tests and/or analyses to demonstrate structural integrity and operability. Structural integrity of the seismic Category I valves is demonstrated by analysis in accordance with American Society of Mechanical Engineers (ASME) Code Section III (Reference 4). Functionality of the subset of active safety-related valves under seismic loads is determined using the guidance of ASME QME-1-2007 (Reference 5).

Safety-related (Class 1E) electrical equipment in the Table is seismically qualified by type testing combined with analysis in accordance with Institute of Electrical and Electronics Engineers (IEEE) Standard 344-1987 (Reference 6). This equipment includes safety-related active valve accessories such as electric actuators, position switches, pilot solenoid valves and electrical connector assemblies. The specific qualification method (i.e., type testing, analysis, or combination) used for each piece of equipment in the Table is identified in Attachment A.

Additional Information about the methods used to qualify AP1000 safety-related equipment is provided in the Updated Final Safety Analysis Report (UFSAR) Appendix 3D (Reference 7).

The EQ Reports (Reference 8) identified in Attachment A contain applicable test reports and associated documentation and conclude that the seismic Category I equipment can withstand seismic design basis loads without loss of safety function,

iin A report exists and concludes that the as-built equipment including anchorage is seismically bounded bv the tested or analyzed conditions.

An inspection (References 1 and 2) was conducted to confirm the satisfactory installation of the seismically qualified equipment in the Table. The inspection verifies the equipment make/model/serial number, as-designed equipment mounting orientation, anchorage and clearances, and electrical and other interfaces. The documentation of installed configuration of U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 4 of 9

seismically qualified equipment includes photographs and/or sketches/drawings of equipment/mounting/interfaces.

As part of the seismic qualification program, consideration was given to the definition of the clearances needed around the equipment mounted in the plant to permit the equipment to move during a postulated seismic event without causing impact between adjacent pieces of safety-related equipment. When required, seismic testing measuring the maximum dynamic relative displacement of the top and bottom of the equipment was performed. EQ Reports (Reference 8) identify the equipment mounting employed for qualification and establish interface requirements for assuring that subsequent in-plant installation does not degrade the established qualification.

Interface requirements are defined based on the test configuration and other design requirements.

Attachment A identifies the EQRR (Reference 3) completed to verify that the as-built seismic Category I equipment listed in the Table, including anchorage, are seismically bounded by the tested or analyzed conditions, IEEE Standard 344-1987 (Reference 6), and NRC Regulatory Guide (RG) 1.100 (Reference 9).

i) A report exists and concludes that the Class 1E equipment identified in Table 2.3.2-1 as being qualified for a harsh environment can withstand the environmental conditions that would exist before, during, and following a desian basis accident without loss of safety function for the time required to perform the safety function.

The harsh environment Class 1E equipment in the Table is qualified by type testing and/or analyses. Class 1E electrical equipment type testing was performed in accordance with IEEE Standard 323-1974 (Reference 10} and RG 1.89 (Reference 11) to meet the requirements of 10 CFR 50.49. Type testing of safety-related equipment meets the requirements of 10 CFR Part 50, Appendix A, General Design Criterion 4. Attachment A identifies the EQ program and specific qualification method for each piece of safety-related mechanical equipment located in a harsh environment. Additional information about the methods used to qualify AP1000 safety-related equipment is provided in the UFSAR Appendix 3D (Reference 7). EQ Reports (Reference 8) identified in Attachment A contain applicable test reports and associated documentation and conclude that the equipment can withstand the environmental conditions that would exist before, during, and following a design basis accident without loss of safety function for the time required to perform the safety function.

ii} A report exists and concludes that the as-built Class 1E equipment and the associated wiring, cables, and terminations identified in Table 2.3.2-1 as being qualified for a harsh environment are bounded by type tests, analyses, or a combination of type tests and analyses.

An inspection (References 1 and 2) was conducted of the CVS to confirm the satisfactory installation of the Class 1E equipment in the Table. The inspection verifies the equipment location, make/model/serial number, as-designed equipment mounting, wiring, cables, and terminations, and confirms that the environmental conditions for the zone (Attachment A) in which the equipment is mounted are bounded by the tested and/or analyzed conditions. It also documented the installed configuration with photographs or sketches/drawings of equipment mounting and connections. The EQRR (Reference 3) identified in Attachment A documents this inspection and concludes that the as-built harsh environment Class 1E equipment and the associated wiring, cables, and terminations are bounded by the qualified configuration and IEEE Standard 323-1974 (Reference 10).

U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 5 of 9

Together, these reports (References 3 and 8) provide evidence that the ITAAC Acceptance Criteria requirements are met:

The seismic Category I equipment identified in Table 2.3.2-1 is located on the Nuclear Island.

A report exists and concludes that the seismic Category I equipment can withstand seismic design basis dynamic loads without toss of safety function.

A report exists and concludes that the as-built equipment including anchorage is seismically bounded by the tested or analyzed conditions.

A report exists and concludes that the Class 1E equipment identified in Table 2.3.2-1 as being qualified for a harsh environment can withstand the environmental conditions that would exist before, during, and following a design basis accident without loss of safety function for the time required to perform the safety function.

A report exists and concludes that the as-built Class 1E equipment and the associated wiring, cables, and terminations identified in Table 2.3.2-1 as being qualified for a harsh environment are bounded by type tests, analyses, or a combination of type tests and analyses.

References 3 and 8 are available for NRC inspection as part of the Unit 4 ITAAC 2.3.02.05.1 Completion Package (Reference 12).

ITAAC Finding Review

In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all ITAAC findings and associated corrective actions.

This review, which included now consolidated ITAAC Indexes 292, 293, 294 and 295, found the following relevant ITAAC finding associated with this ITAAC:

1) Notice of Nonconformance (NON) 99901412/2012-201-02 (Closed)

ITAAC Completion Statement

Based on the above information, SNC hereby notifies the NRC that ITAAC 2.3.02.05.I was performed for VEGP Unit 4 and that the prescribed acceptance criteria are met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with the approved plant programs and procedures.

References (available for NRC inspection)

1. ND-RA-001-014, EQ ITAAC As-built Walkdown Guideline, Version 3.1
2. ND-RA-001-016, EQ ITAAC As-built Installation Documentation Guideline, Version 1,0 U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 6 of 9
3. EQ As-Built Reconciliation Report (EQRR) as identified in Attachment A for Unit 4
4. American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV)

Code,Section III, Rules for Construction of Nuclear Power Plant Components, 1998 Edition with 2000 Addenda

5. ASME QME-1-2007, Qualification of Active Mechanical Equipment Used in Nuclear Power Plants, The American Society of Mechanical Engineers, June 2007
6. IEEE Standard 344-1987, IEEE Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations
7. Vogtie 3&4 Updated Final Safety Analysis Report Appendix 3D, Methodology for Qualifying API 000 Safety-Related Electrical and Mechanical Equipment"
8. Equipment Qualification (EQ) Reports as identified in Attachment A
9. Regulatory Guide 1.100, Rev. 2, "Seismic Qualification of Electric and Mechanical Equipment for Nuclear Power Plants"
10. IEEE Standard 323-1974, "IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations"
11. Regulatory Guide 1.89, Rev 1, "Environmental Qualification of Certain Electric Equipment Important to Safety for Nuclear Power Plants"
12. 2.3.02.05.i-U4-CP-Rev0, ITAAC Completion Package U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 7 of 9

Attachment A

System: Chemical and Volume Control System (CVS)

Class 1E/

Tag No. ^ Seismic Qual. for Envir. Envir Qual Type of EQ Reports As-Built EQRR Equipment Name

  • Cat. I ^ Harsh Zone1 Program^ Qual. (Reference 8) (Reference 3)

Envir/^

RCS Purification Motor-CVS-PL-V001 Yes YesA'es 1 M

  • E S Type Testing SV4-PV01-VBR-012/ 2.3.02.05.i-U4-EQRR-operated Isolation Valve & Analysis SV4-PV01-VBR-011 PCD001-Rev0 RCS Purification Motor-CVS-PL-V002 Yes YesA^es 1 M*ES Type Testing SV4-PV01-VBR-012/ 2.3.02.05.i-U4-EQRR-operated Isolation Valve & Analysis SV4-PV01-VBR-011 PCD001-Rev0 RCS Purification Motor-CVS-PL-V003 Yes YesA'es 1 M
  • ES Type Testing SV4-PV01-VBR-014/ 2.3.02.05J-U4-EQRR-operated Isolation Valve & Analysis SV4-PV01-VBR-013 PCD001-Rev0 CVS Resin Flush Line Type Testing SV4-PV10-VBR-008/ 2.3.02.05.i-U4-EQRR-Containment Isolation CVS-PL-V040 Yes -/- NA NA & Analysis SV4-PV10-VBR-007 PCD001-Rev0 Valve CVS Resin Flush Line Type Testing SV4-PV10-VBR-008/ 2.3.02.05.i-U4-EQRR-Containment Isolation CVS-PL-V041 Yes -/- NA NA & Analysis SV4-PV10-VBR-007 PCD001-Rev0 Valve CVS Demineralizer Resin Flush Line ContainmentCVS-PL-V042 Yes -/- NA NA Type Testing SV4-PV16-VBR-002/ 2.3.02.05.I-U4-EQRR-Isolation Thermal Relief & Analysis SV4-PV16-VBR-001 PCD001-Rev0 Valve CVS Letdown Type Testing SV4-PV14-VBR-002/ 2.3.02.05.I-U4-EQRR-Containment Isolation CVS-PL-V045 Yes YesA'es 1 M*ES & Analysis SV4-PV14-VBR-001 PCD001-Rev0 Valve CVS Letdown Type Testing SV4-PV14-VBR-002 / 2.3.02.05J-U4-EQRR-Containment Isolation CVS-PL-V047 Yes Yes/No NA NA & Analysis SV4-PV14-VBR-001 PCD001-Rev0 Valve CVS Letdown Line Type Testing SV4-PV16-VBR-002/ 2.3.02.05.I-U4-EQRR-Containment Isolation CVS-PL-V058 Yes NA NA & Analysis SV4-PV16-VBR-001 PCD001-Rev0 Thermal Relief Valve CVS Makeup Return LineCVS-PL-V067 Yes Type Testing SV4-PV02-VBR-012/ 2.3.02.05.i-U4-EQRR-Bypass Check Valve -/- NA NA & Analysis SV4-PV02-VBR-011 PCD001-Rev0 U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 8 of 9

Class 1E/

Equipment Name ^ Tag No.

  • Seismic Qual. for Envir. Envir Qual Type of EQ Reports As-BuMt EQRR Cat. I
  • Harsh Zone^ Program^ Qual. (Reference 8) (Reference 3)

Envir.+ 3 CVS Purification Return SV4-PV03-VBR-014/ 2.3.02.05J-U4-EQRR-Line Pressure BoundaryCVS-PL-V080 Yes -/- NA NA Analysis SV4-PV03-VBR-013 PCD001-Rev0 Check Valve CVS Purification Return Type TestingSV4-PV14-VBR-190002 2.3.02.05.i-U4-EQRR-Line Pressure BoundaryCVS-PL-V081 Yes -/- NA NA & Analysis / PCD001-Rev0 Isolation Check Valve SV4-PV14-VBR-190001 CVS Purification Return SV4-PV03-VBR-014/ 2.3.02.05.i-U4-EQRR-Line Pressure BoundaryCVS-PL-V082 Yes -/- NA NA Analysis SV4-PV03-VBR-013 PCD001-Rev0 Check Valve CVS Auxiliary Pressurizer M*ES Type Testing SV4-PV14-VBR-002/ 2.3.02.05J-U4-EQRR-Spray Line Pressure CVS-PL-V084 Yes YesA'es 1 & Analysis SV4-PV14-VBR-001 PCD001-Rev0 Boundary Valve CVS Auxiliary Pressurizer -/- NA NA SV4-PV02-VBR-012/ 2.3.02.05.i-U4-EQRR-Spray Line Pressure CVS-PL-V085 Yes Analysis SV4-PV02-VBR-011 PCD001-Rev0 Boundary Check Valve CVS Makeup Line Type Testing 2.3.02.05.i-U4-EQRR-Containment Isolation SV4-PV01-VBR-012/CVS-PL-V090 YesYes/No NA NA& AnalysisSV4-PV01-VBR-011PCD001-Rev0 Motor-operated Valve CVS Makeup Line Type Testing SV4-PV01-VBR-012/ 2.3.02.05J-U4-EQRR-Containment Isolation CVS-PL-V091 Yes YesA'es 1 M*ES & Analysis SV4-PV01-VBR-011 PCD001-Rev0 Motor-operated Valve CVS Zinc Injection Type Testing SV4-PV14-VBR-002/ 2.3.02.05.i-U4-EQRR-Containment Isolation CVS-PL-V092 Yes YesA'es 10 M*ES & Analysis SV4-PV14-VBR-001 PCD001-Rev0 Valve ORC CVS Zinc Injection Type Testing SV4-PV14-VBR-002/ 2.3.02.05.I-U4-EQRR-Containment Isolation CVS-PL-V094 Yes Yes / Yes 1 M*ES & Analysis SV4-PV14-VBR-001 PCDOOI-RevO Valve IRC CVS Zinc Addition Line Type Testing SV4-PV16-VBR-002/ 2.3.02.05.i-U4-EQRR-Ctmt Isol Thermal ReliefCVS-PL-V098 Yes -/- NA NA & Analysis SV4-PV16-VBR-001 PCDOOI-RevO Valve U.S. Nuclear Regulatory Commission ND-22-0600 Enclosure Page 9 of 9

Class 1E/

Seismic Qual. for Envir. Type of EQ Reports As-Built EQRR Equipment Name Tag No. Cat. I

  • Harsh Zone1 Envir QualProgram^Qual. (Reference 8) (Reference 3)

Envlr.^^

CVS Makeup Line CVS-PL-V100 Yes -/- NA NA SV4-PV02-VBR-012/ 2.3.02.05.i-U4-EQRR-Containment Isolation Analysis SV4-PV02-VBR-011 PCD001-Rev0 Thermal Relief Valve CVS Demineralized CVS-PL-V136A Yes Yes/No NA Type Testing SV4-PV11-VBR-004/ 2.3.02.05J-U4-EQRR-Water Isolation Valve NA & Analysis SV4-PV11-VBR-003 PCD001-Rev0 CVS Demineralized CVS-PL-V136B Yes Yes/No NA Type Testing SV4-PV11-VBR-004/ 2.3.02.05.i-U4-EQRR-Water Isolation Valve NA & Analysis SV4-PV11-VBR-003 PCD001-Rev0 CVS Hydrogen Injection -/- NA NA SV4-PV02-VBR-017/ 2.3.02.05.i-U4-EQRR-Containment Isolation CVS-PL-V217 Yes Analysis SV4-PV02-VBR-018 PCD001-Rev0 Check Valve IRC CVS Hydrogen Injection YesA'es 10 M*ES Type Testing SV4-PV14-VBR-002/ 2.3.02.05.i-U4-EQRR-Containment Isolation CVS-PL-V219 Yes & Analysis SV4-PV14-VBR-001 PCD001-Rev0 Valve ORC

Notes:

+ Excerpt from COL Appendix C Table 2.3.2-1

1. See Table 3D.5-1 of UFSAR
2. E - Electrical Equipment Program (limit switch and the motor operator, squib operator, solenoid operator)

M - Mechanical Equipment Program (valve)

S = Qualified for submergence or operation with spray

  • - Harsh Environment
3. Dash (-) indicates not applicable