MONTHYEARML22262A2642022-08-29029 August 2022, 30 August 2022 Certificate of Compliance No. 9365, Revision 3, Amendment Request Project stage: Request ML22262A2652022-08-29029 August 2022 Certificate of Compliance No. 9365, Revision 3, Amendment Request Cover Letter Project stage: Other ML22312A3622022-11-21021 November 2022 Letter - Application for Amendment to Certificate of Compliance for the Model No. RT-100 Package - Supplemental Information Needed Project stage: Other ML22335A0812022-11-22022 November 2022 Robatel Technologies Responses to the Us NRC Request for Supplemental Information for Model No. RT-100 Package, Docket No. 71-9365 Project stage: Request ML22339A1002022-12-0606 December 2022 Amendment Request for Certificate of Compliance No. 9365 for the Model No. RT-100 Package-Accepted for Review Project stage: Other NL-23-0076, Exigent License Amendment Request: Technical Specification Exceptions for In-containment Refueling Water Storage Tank Operability Prior to Initial Criticality (LAR-23-004)2023-01-31031 January 2023 Exigent License Amendment Request: Technical Specification Exceptions for In-containment Refueling Water Storage Tank Operability Prior to Initial Criticality (LAR-23-004) Project stage: Request ML23045A0912023-02-27027 February 2023 Letter Request for Additional Information for Review of the Model No. RT-100 Package Project stage: RAI ML23095A0662023-03-31031 March 2023 Robatel Technologies, LLC, Request an Extension of Submittal Date of NRCs Request for Additional Information for the Review of the Model RT-100 Project stage: Request ML23143A1772023-05-19019 May 2023 Robatel Request for Additional Information Response Project stage: Request ML23181A1272023-06-20020 June 2023 RT-100 RAI Clarification Response Project stage: Request NRC-23-0049, Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)2023-07-24024 July 2023 Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS) Project stage: Request ML23191A8512023-07-28028 July 2023 Certificate of Compliance No. 9365, Revision No. 3, for the Model No. RT-100 Package Project stage: Request ML23191A8522023-07-28028 July 2023 Enclosure 2 - Certificate of Compliance No. 9365, Revision No. 3, for the Model No. RT-100 Package Project stage: Other ML23191A8532023-07-28028 July 2023 Certificate of Compliance No. 9365, Revision No. 3, for the Model No. RT-100 Package Transmittal Letter Project stage: Other ML23191A8552023-07-28028 July 2023 Enclosure 1 - Certificate of Compliance No. 9365, Revision No. 3, for the Model No. RT-100 Package Safety Evaluation Report Project stage: Approval NRC-23-0050, Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)2023-08-10010 August 2023 Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS) Project stage: Request NRC-23-0059, Response to Request for Additional Information Exigent License Amendment Request for Technical Specification 3.7.2,Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)2023-08-25025 August 2023 Response to Request for Additional Information Exigent License Amendment Request for Technical Specification 3.7.2,Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS) Project stage: Response to RAI NRC-23-0068, Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating2023-09-28028 September 2023 Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating Project stage: Request NRC-23-0072, Clarification for RAI Response from 10-16-23 Phone Call Regarding Exigent License Amendment Request for Exigent License Amendment Request for Technical Specification 3.8.1, AC Sources - Operating - in Relation to Mechanical Draft Cool2023-10-18018 October 2023 Clarification for RAI Response from 10-16-23 Phone Call Regarding Exigent License Amendment Request for Exigent License Amendment Request for Technical Specification 3.8.1, AC Sources - Operating - in Relation to Mechanical Draft Cool Project stage: Draft Request 05000341/LER-2023-003, Reactor Pressure Boundary Leakage at Socket Weld on Reactor Recirculation Sample Line Caused by Fatigue Failure2023-10-18018 October 2023 Reactor Pressure Boundary Leakage at Socket Weld on Reactor Recirculation Sample Line Caused by Fatigue Failure Project stage: Request ML23297A0512023-10-30030 October 2023 Issuance of Amendment No. 226 Regarding Revision of Technical Specifications 3.8.1, AC Sources - Operating (Exigent Circumstances) Project stage: Approval 2023-02-27
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Abdulsalam Shakhatreh Engineering Manager Robatel Technologies 5115 Bernard Drive Suite 304 Roanoke, VA 24018
SUBJECT:
AMENDMENT REQUEST FOR CERTIFICATE OF COMPLIANCE NO. 9365 FOR THE MODEL NO. RT-100 PACKAGE - ACCEPTED FOR REVIEW
Dear Abdulsalam Shakhatreh:
By letter dated August 29, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22262A264), as supplemented November 22, 2022 (ADAMS Accession No. ML22335A081), you submitted an application to revise Certificate of Compliance (CoC) No. 9365, for the Model No. RT-100 transport package. The application proposes to add activated hardware as new contents and provide flexibility to ship filters of varying activities.
The staff performed an acceptance review of your application and determined the application contains sufficient technical information in scope and depth to allow the staff to complete a detailed technical review.
We have established a schedule for the review and estimated that the staff may need approximately 600 staff review hours. The schedule allows for the staff to issue a request for additional information (RAI) in March 2023 and, if a second RAI is not needed, a CoC in June 2023, based on you responding to the first RAI in April 2023. In general, no additional changes to the application should be submitted except for changes resulting from your response to an RAI.
If you have any questions regarding this matter, please contact me at (301) 415-6877.
Sincerely, Chris Allen, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9365 EPID NO. L-2022-LLA-0134 cc w/encls 71bw9365all@listmgr.nrc.gov December 6, 2022 Signed by Allen, William on 12/06/22