Cheryl A. Gayheart 3535 Colonnade Parkway Regulatory Affairs Director Birmingham, AL 35243 205 992 5316 tel 205 992 7601 fax cagayhea@southernco.com September 30, 2022 Docket Nos.: 50-321 NL-22-0757 50-366 10 CFR 50.90 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b" Ladies and Gentlemen:

On October 26, 2021 [ADAMS Accession Number ML21300A153], pursuant to the provisions of Section 50.90 of Title 10 of the Code of Federal Regulations, Southern Nuclear Operating Company (SNC) requested amendments to Edwin I. Hatch Nuclear Plant (HNP), Units 1 and 2 renewed facility operating licenses (RFOLs) DPR-57 and NPF-5, respectively. The proposed amendment requested U.S. Nuclear Regulatory Commission (NRC) approval to modify Technical Specifications (TS) requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 2, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b" [ML18183A493]. The LAR impacted several TS sections, including TS 3.6.1.3 On December 6, 2021, subsequent to the submittal of the HNP TSTF-505 license amendment request (LAR), SNC submitted a LAR to adopt certain aspects of TSTF-207 [ML21340A255].

On September 2, 2022, the NRC issued Amendments 317 and 262 to the HNP Units 1 and 2 RFOLs, respectively, approving SNCs Hatch TSTF-207 LAR. Amendments 317 and 262 include changes to some of the same pages in TS 3.6.1.3 as SNCs HNP TSTF-505 LAR.

The Enclosure to this letter describes the TS markup changes and assesses their impact on SNCs Hatch TSTF-505 LAR.

The Attachment to this letter updates the TS markups, provided initially in the license amendment request dated October 26, 2021, to include the effects of Amendments 317 and 262. These markups supersede only the TS 3.6.1.3 markups provided in the initial license amendment request dated October 26, 2021.

SNC requests the same approval and implementation schedule as requested in its original application [ML21300A153]. The conclusions of the No Significant Hazards Consideration Determination and Environmental Consideration contained in the original application have been reviewed and are unaffected by this supplement.

U. S. Nuclear Regulatory Commission NL-22-0757 Page 2 of 2 In accordance with 10 CFR 50.91, SNC is notifying the State of Georgia of this supplement to license amendment request by transmitting a copy of this letter, with attachment, to the designated State Official.

This letter contains no regulatory commitments. If you have any questions, please contact Amy Chamberlain at 205.992.6361.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 30th day of September 2022.

Respectfully submitted, C. A. Gayheart Director, Regulatory Affairs Southern Nuclear Operating Company CAG/agq

Enclosure:

Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request

Attachment:

Revised TSTF-505 Markups Reflecting Amendments 317 and 262 cc: Regional Administrator, Region ll NRR Project Manager - Hatch Senior Resident Inspector - Hatch Director, Environmental Protection Division - State of Georgia RType: CHA02.004

Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b" NL-22-0757 Enclosure Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Enclosure consists of 6 pages, excluding this cover page

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request

1.0 INTRODUCTION

On October 26, 2021 [ADAMS Accession Number ML21300A153], Southern Nuclear Operating Company (SNC) requested amendments to Edwin I. Hatch Nuclear Plant (HNP), Units 1 and 2 renewed facility operating licenses (RFOLs) DPR-57 and NPF-5, respectively. The proposed amendment requested U.S. Nuclear Regulatory Commission (NRC) approval to modify Technical Specifications (TS) requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 2, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b" [ML18183A493]. The LAR impacted several TS sections, including TS 3.6.1.3, Primary Containment Isolation Valves.

On December 6, 2021, subsequent to the submittal of the HNP TSTF-505 license amendment request (LAR), SNC submitted a LAR to adopt certain aspects of TSTF-207 [ML21340A255].

On September 2, 2022, the NRC issued Amendments 317 and 262 to the HNP Units 1 and 2 RFOLs, respectively, approving SNCs HNP TSTF-207 LAR. Amendments 317 and 262 include changes to some of the same pages in TS 3.6.1.3 as SNCs TSTF-505 LAR.

2.0 DESCRIPTION

OF CHANGE AND ASSESSMENT OF IMPACT The issuance of HNP RFOL Amendments 317 and 262 included issuance of revised TS pages 3.6-7 through 3.6-12 (impacts TS 3.6.1.3 Conditions A through D and Required Action D.1 Completion Time). The Hatch TSTF-505 LAR included changes to TS pages 3.6-7 through 3.6-9 (impacts Condition A Required Actions and Completion Times and Required Action Completion Time C.2), thus there is overlap in the affected pages. Table 1 provides descriptions of the changes and assess the impact Amendments 317 and 262 have on SNCs HNP TSTF-505 LAR.

E-1

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Table 1: Descriptions of Changes and Assessment of Impact (Sheet 1 of 5)

TS 3.6.1.3 Condition Amendment 317 and 262 HNP TSTF-505 LAR (1)(2)

Changes (3) Proposed Changes (3) Assessment of Impact to HNP TSTF-505 LAR A Revised Condition A Note as Adds following Note to The addition of or more to the Note of TS 3.6.1.3, Condition A, follows: Required Action A.1: clarifies that the Condition applies to penetration flow paths with more than two PCIVs. This was an administrative change aligning the HNP Only applicable to penetration Not applicable to main steam TS with TSTF-207-A, Revision 5 as implemented in the Boiling Water flow paths with two or more line. Reactor (BWR) Owners Group Standard Technical Specifications PCIVs.

(STS), NUREG-1433. Due to the administrative nature of this change, there is no impact to the proposed note that the HNP TSTF-505 LAR adds to Required Action A.1 (which is also an administrative change itself as described in Attachment 1, Section 2.3 of the HNP TSTF-505 LAR [ML21300A153]).

Revised Condition A as Revises Required Action A.1 Rewording the exception to refer to reasons other than TS 3.6.1.3 follows: Completion Time as follows: Condition D is an administrative/equivalent change since TS 3.6.1.3 Condition D and TS 3.6.1.1 have required actions for leakage not One or more penetration flow 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> except for main steam within limits. Due to the administrative nature of this change, other than paths with one PCIV line changes to background text in the TS markups, there is no impact to inoperable except due to the proposed change that the HNP TSTF-505 LAR makes to Required leakage not within limit for OR Action A.1 (which is also an administrative change itself as described in reasons other than Condition Attachment 1, Section 2.3 of the HNP TSTF-505 LAR).

D.

In accordance with the Risk Informed Completion Time Program AND 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for main steam line E-2

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Table 1: Descriptions of Changes and Assessment of Impact (Sheet 2 of 5)

TS 3.6.1.3 Condition Amendment 317 and 262 HNP TSTF-505 LAR (1)(2)

Changes (3) Proposed Changes (3) Assessment of Impact to HNP TSTF-505 LAR A (contd) Adds new Required Action The assessment of Required Action A.1 in previous row also applies to A.2 as follows: the addition of a new Required Action A.2.


NOTE---------------

Only applicable to main steam line.

Isolate the affected penetration flow path by use of at least one closed and de-activated automatic valve, closed manual valve, blind flange, or check valve with flow through the valve secured.

Adds new Required Action The assessment of Required Action A.1 in previous row also applies to A.2 Completion Time as the addition of a Completion Time for new Required Action A.2.

follows:

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> OR In accordance with the Risk Informed Completion Time Program E-3

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Table 1: Descriptions of Changes and Assessment of Impact (Sheet 3 of 5)

TS 3.6.1.3 Condition Amendment 317 and 262 HNP TSTF-505 LAR (1)(2)

Changes (3) Proposed Changes (3) Assessment of Impact to HNP TSTF-505 LAR A (contd) Renumbers Required Action This is an administrative change due to making Required Action A.1 A.2 to A.3 as follows: two separate Required Actions, A.1 and A.2. Amendments 317 and 262 have no impact on this change.

A.23 Revises first part of new The HNP TSTF-505 LAR adds following isolation in accordance with Required Action A.3 TSTF-505-A, Revision 2 to account for the time change caused by Completion Time as follows: RICT implementation. The Amendment 317 and 262 change to Condition A have no impact on this change.

Once per 31 days following isolation for isolation devices outside primary containment B Revised Condition B Note as The addition of or more to the Note of TS 3.6.1.3, Condition B, follows: clarifies that the Condition applies to penetration flow paths with more than two PCIVs. This was an administrative change aligning the HNP Only applicable to penetration TS with TSTF-207-A, Revision 5 as implemented in the BWR Owners flow paths with two or more Group STS, NUREG-1433. Due to the administrative nature of this PCIVs.

change, there would be no change in application of the HNP TSTF-505 LAR proposed changes, and there is no impact to the HNP TSTF-505 LAR other than changes to background information in the TS markups.

E-4

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Table 1: Descriptions of Changes and Assessment of Impact (Sheet 4 of 5)

TS 3.6.1.3 Condition Amendment 317 and 262 HNP TSTF-505 LAR (1)(2)

Changes (3) Proposed Changes (3) Assessment of Impact to HNP TSTF-505 LAR B (contd) Changed Condition B as See discussion of Condition A change above. Additionally, Condition B follows: is not involved in the HNP TSTF-505 LAR, so there is no impact to the HNP TSTF-505 LAR other than changes to background text in the TS One or more penetration flow markups.

paths with two or more PCIVs inoperable except due to leakage not within limit for reasons other than Condition D.

C Changed Condition C as Revises Required Action C.2 The discussion of the Condition A change above also applies to follows: Completion Time as follows: Condition C.

One or more penetration flow Once per 31 days following The HNP TSTF-505 LAR adds following isolation in accordance with paths with one PCIV isolation TSTF-505-A, Revision 2 to account for the time change caused by inoperable except due to RICT implementation. The Amendment 317 and 262 changes to leakage not within limit for Condition C have no impact on this change.

reasons other than Condition D.

D Changed Condition D as This change specifies the individual types of penetration flow paths to follows: which the Condition applies. The HNP TSTF-505 LAR does not propose applying Risk Informed Completion Time to the Condition D One or more penetration flow Required Action. Therefore, there is no impact to the HNP TSTF-505 paths with leakage secondary LAR aside from changes to background text in the TS markups.

containment bypass leakage rate, MSIV leakage rate, or EFCV leakage rate not within limit.

E-5

NL-22-0757 Assessment of Amendments 317 and 262 Impact on HNP TSTF-505 License Amendment Request Table 1: Descriptions of Changes and Assessment of Impact (Sheet 5 of 5)

TS 3.6.1.3 Condition Amendment 317 and 262 HNP TSTF-505 LAR (1)(2)

Changes (3) Proposed Changes (3) Assessment of Impact to HNP TSTF-505 LAR D (contd) Changed Required Action D.1 This change specifies Completion Times for the Required Actions Completion Time as follows: associated with the individual types of penetration flow paths identified.

The HNP TSTF-505 LAR does not propose applying Risk Informed 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for secondary Completion Time to the Condition D Required Action. Therefore, there containment bypass leakage is no impact to the HNP TSTF-505 LAR aside from changes to AND background text in the TS markups.

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for MSIV leakage AND 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for EFCV leakage Notes:

1. Due to formatting of tracked changes, some text rolls to pages 3.6-8, 3.6-9, and 3.6-10. Therefore, the changes are compared on a TS Condition basis.
2. Conditions listed apply to Unit 1 TS and Unit 2 TS pages.
3. Underline format (e.g., underline) text indicates added text, and strikethrough format (e.g., deleted) text indicates deleted text.

E-6

Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b" NL-22-0757 Attachment Revised TSTF-505 Markups Reflecting Amendments 317 and 262 Note:

Blue underline indicates new text proposed in submittal dated October 26, 2021 Red strikethrough indicates deleted text proposed in submittal dated October 26, 2021 Green underline indicates new text added by Amendments 317 and 262 Grey strikethrough indicates text deleted by Amendments 317 and 262 Attachment consists of 8 pages, excluding this cover page

PCIVs 3.6.1.3 3.6 CONTAINMENT SYSTEMS 3.6.1.3 Primary Containment Isolation Valves (PCIVs)

LCO 3.6.1.3 Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.

APPLICABILITY: MODES 1, 2, and 3.

ACTIONS


NOTES-----------------------------------------------------------

1. Penetration flow paths except for 18 inch purge valve penetration flow paths may be unisolated intermittently under administrative controls.
2. Separate Condition entry is allowed for each penetration flow path.
3. Enter applicable Conditions and Required Actions for systems made inoperable by PCIVs.
4. Enter applicable Conditions and Required Actions of LCO 3.6.1.1, "Primary Containment," when PCIV leakage results in exceeding overall containment leakage rate acceptance criteria.

CONDITION REQUIRED ACTION COMPLETION TIME A. -------------NOTE--------------- A.1 -------------NOTE----------

Only applicable to Not applicable to main penetration flow paths with steam line.

two or more PCIVs. --------------------------------

One or more penetration Isolate the affected 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> except for flow paths with one PCIV penetration flow path by main steam line inoperable except due to use of at least one leakage not within limit for closed and de-activated ANDOR reasons other than automatic valve, closed Condition D. manual valve, blind 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for main flange, or check valve steam line with flow through the In accordance with the valve secured. Risk Informed Completion Time Program AND (continued)

HATCH UNIT 1 3.6-7 Amendment No. 317

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. (continued) A.2 ------------NOTE-----------

Only applicable to main steam line.

Isolate the affected 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> penetration flow path by use of at least one OR closed and de-activated automatic valve, closed In accordance with the manual valve, blind Risk Informed flange, or check valve Completion Time with flow through the Program valve secured.

AND A.32 -----------NOTES----------

1. Isolation devices in high radiation areas may be verified by use of administrative means.
2. Isolation devices that are locked, sealed, or otherwise secured may be verified by administrative means.

Verify the affected Once per 31 days penetration flow path is following isolation for isolated. isolation devices outside primary containment AND (continued)

HATCH UNIT 1 3.6-8 Amendment No. 317

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. (continued) Prior to entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days, for isolation devices inside primary containment B. -------------NOTE--------------- B.1 Isolate the affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Only applicable to penetration flow path by penetration flow paths with use of at least one two or more PCIVs. closed and de-activated


automatic valve, closed manual valve, or blind One or more penetration flange.

flow paths with two or more PCIVs inoperable except due to leakage not within limit for reasons other than Condition D.

C. ---------------NOTE------------- C.1 Isolate the affected 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> except for Only applicable to penetration flow path by excess flow check penetration flow paths with use of at least one valve (EFCV) line and only one PCIV. closed and de-activated penetrations with a


automatic valve, closed closed system manual valve, or blind One or more penetration flange. AND flow paths with one PCIV inoperable except due to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for leakage not within limits for EFCV line and reasons other than penetrations with a Condition D. closed system AND (continued)

HATCH UNIT 1 3.6-9 Amendment No. 317

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME C. (continued) C.2 -----------NOTES----------

1. Valves and blind flanges in high radiation areas may be verified by use of administrative means.
2. Isolation devices that are locked, sealed, or otherwise secured may be verified by administrative means.

Verify the affected Once per 31 days penetration flow path is following isolation isolated.

D. One or more penetration D.1 Restore leakage to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for secondary flow paths with leakage within limit. containment bypass secondary containment leakage bypass leakage rate, MSIV leakage rate, or EFCV AND leakage rate not within limit. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for MSIV leakage AND 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for EFCV leakage E. Required Action and E.1 Be in MODE 3. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition A, B, C, AND or D not met.

E.2 Be in MODE 4. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> HATCH UNIT 1 3.6-10 Amendment No. 317

PCIVs 3.6.1.3 3.6 CONTAINMENT SYSTEMS 3.6.1.3 Primary Containment Isolation Valves (PCIVs)

LCO 3.6.1.3 Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.

APPLICABILITY: MODES 1, 2, and 3.

ACTIONS


NOTES------------------------------------------------------------

1. Penetration flow paths except for 18 inch purge valve penetration flow paths may be unisolated intermittently under administrative controls.
2. Separate Condition entry is allowed for each penetration flow path.
3. Enter applicable Conditions and Required Actions for systems made inoperable by PCIVs.
4. Enter applicable Conditions and Required Actions of LCO 3.6.1.1, "Primary Containment," when PCIV leakage results in exceeding overall containment leakage rate acceptance criteria.

CONDITION REQUIRED ACTION COMPLETION TIME A. --------------NOTE--------------- A.1 ------------NOTE-----------

Only applicable to Not applicable to main penetration flow paths with steam line.

two or more PCIVs. --------------------------------

One or more penetration Isolate the affected 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> except for flow paths with one PCIV penetration flow path by main steam line inoperable except due to use of at least one leakage not within limit for closed and de-activated ANDOR reasons other than automatic valve, closed Condition D. manual valve, blind 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for main flange, or check valve steam line with flow through the In accordance with the valve secured. Risk Informed Completion Time Program AND (continued)

HATCH UNIT 2 3.6-7 Amendment No. 262

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. (continued) A.2 ------------NOTE-----------

Only applicable to main steam line.

Isolate the affected 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> penetration flow path by use of at least one OR closed and de-activated automatic valve, closed In accordance with the manual valve, blind Risk Informed flange, or check valve Completion Time with flow through the Program valve secured.

AND A.32 ------------NOTES-----------

1. Isolation devices in high radiation areas may be verified by use of administrative means.
2. Isolation devices that are locked, sealed, or otherwise secured may be verified by administrative means.

Verify the affected Once per 31 days penetration flow path is following isolation for isolated. isolation devices outside primary containment AND (continued)

HATCH UNIT 2 3.6-8 Amendment No. 262

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. (continued) Prior to entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days, for isolation devices inside primary containment B. --------------NOTE--------------- B.1 Isolate the affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Only applicable to penetration flow path by penetration flow paths with use of at least one two or more PCIVs. closed and de-activated


automatic valve, closed manual valve, or blind One or more penetration flange.

flow paths with two or more PCIVs inoperable except due to leakage not within limit for reasons other than Condition D.

C. --------------NOTE--------------- C.1 Isolate the affected 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> except for Only applicable to penetration flow path by excess flow check penetration flow paths with use of at least one valve (EFCV) line and only one PCIV. closed and de-activated penetrations with a


automatic valve, closed closed system manual valve, or blind One or more penetration flange. AND flow paths with one PCIV inoperable except due to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for leakage not within limits for EFCV line and reasons other than penetrations with a Condition D. closed system AND (continued)

HATCH UNIT 2 3.6-9 Amendment No. 262

PCIVs 3.6.1.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME C. (continued) C.2 ----------NOTES-----------

1. Valves and blind flanges in high radiation areas may be verified by use of administrative means.
2. Isolation devices that are locked, sealed, or otherwise secured may be verified by administrative means.

Verify the affected Once per 31 days penetration flow path is following isolation isolated.

D. One or more penetration D.1 Restore leakage to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for secondary flow paths with leakage within limit. containment bypass secondary containment leakage bypass leakage rate, MSIV leakage rate, or EFCV AND leakage rate not within limit. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for MSIV leakage AND 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for EFCV leakage E. Required Action and E.1 Be in MODE 3. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition A, B, C, AND or D not met.

E.2 Be in MODE 4. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> HATCH UNIT 2 3.6-10 Amendment No. 262