September 30, 2022 MEMORANDUM TO:

Michael I. Dudek, Chief New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation FROM:

Carolyn Lauron, Sr. Project Manager

/RA/

New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation

SUBJECT:

U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE SEPTEMBER 13, 2022, PREAPPLICATION PUBLIC MEETING WITH SMR, LLC TO DISCUSS QUESTIONS REGARDING CONTROL ROD DRIVE SYSTEM The U.S. Nuclear Regulatory Commission (NRC) held a preapplication public meeting on September 13, 2022, with SMR, LLC (SMR), a Holtec International Company, to discuss questions regarding the control rod drives system (CRDS) to support the construction permit application for the SMR-160 design. Specifically, SMR (applicant) requested the meeting to provide the staff with a high-level overview of the SMR-160 CRDS design and the associated Standard Review Plan Section 3.9.4 testing requirements and to discuss acceptable analytical methods that can be used in lieu of prototype testing, and industry experience and plant referenced designs that preclude the use of analytical methods.1,2 This virtual preapplication meeting had attendees from SMR, LLC, Holtec International, LLC, and the NRC staff. No members of the public participated in the meeting.

CONTACT: Carolyn Lauron, NRR/DNRL 301-415-2736 1

SMR, LLC, Preapplication Materials for September 13, 2022 (Project No. 99902049, dated September 13, 2022. Agencywide Documents and Access Management System (ADAMS) Accession No. ML22256A019.

2 U.S. NRC, NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition (NUREG-0800, Formerly issued as NUREG-75/087), Chapter 3, Design of Structures, Components, Equipment, and Systems, Section 3.9.4, Control Rod Drive Systems, ML16133A472.

M. Dudek 2

The NRC issued the public meeting notice on August 16, 2022, and posted it on the NRC public website.3 Enclosed are the meeting agenda (Enclosure 1), list of participants for the meeting (Enclosure 2), and a summary of the meeting (Enclosure 3).

Docket No. 99902049

Enclosures:

1. Meeting Agenda
2. List of Attendees
3. Summary of Meeting 3 U.S. NRC, 9/13/2022 Notice of Preapplication Meeting with Holtec International, LLC, regarding control rod drive system to support the Construction Permit for the SMR-160 design, dated August 16, 2022.

(ML22242A185)

PKG: ML22252A181 Memo: ML22252A182 : ML22252A183 : ML22252A193 : ML22252A194

  • via email NRR-106

Page 1 of 2 HOLTEC - Mailing List Revised 08/15/2022 cc:

Thomas Marcille Vice President, SMR Reactor Technologies SMR, LLC, a wholly owned subsidiary of Holtec International 1 Holtec Boulevard Camden, NJ 08104 Jean Fleming Vice President, Licensing, Regulatory & PSA Holtec International 1 Holtec Boulevard Camden, NJ 08104 Justin Hawkins Director, SMR Licensing Holtec International 1 Holtec Boulevard Camden, NJ 08104 Rick Trotta Director, SMR SMR, LLC, a wholly owned subsidiary of Holtec International 1 Holtec Boulevard Camden, NJ 08104

Page 2 of 2 HOLTEC - Mailing List Email J.Fleming@holtec.com (J. Fleming)

J.Hawkins@holtec.com (Justin Hawkins)

R.Trotta@holtec.com (Rick Trotta)

T.Marcille@holtec.com (Thomas Marcille)