1 to Updated Final Safety Analysis Report, Chapter 2.5, Figures, Part 2_Redacted
ML22245A059
Person / Time
Site: Seabrook 
Issue date: 05/05/2022
From:
NextEra Energy Seabrook
To:
Office of Nuclear Reactor Regulation
Poole J, NRR/DORL/LPLI, 415-2048
Shared Package
ML22244A196 List:
References
SBK-L-22042
Download: ML22245A059 (23)


Text

Offsite Borrow SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-51

Offsite Borrow Compaction Test Results - Typical Winter Period SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-52

Offsite Borrow Compaction Test Results - Typical Spring Period SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-53

Offsite Borrow Compaction Test Results - Typical Summer Period SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-54

Offsite Borrow Compaction Test Results 95% Critieria -

Revetment Area SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-55

Offsite Borrow Compaction Test Results 90% Critieria -

Revetment Area SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-56

Tunnel Cuttings Compaction Test Results SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-57

Sand-Cement Test Results SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-58

Fill Concrete Test Results SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-59

Backfill Concrete Test Results SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-60

Tunnel Cuttings SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-61

Overall View of Foundation Excavations, Looking East from Unit 2 toward Unit 1 SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-62

Foundation Excavation for Service and Circulating Water Pumphouse Looking North SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-63

Summary Plot of Compaction Curves for Tunnel Cuttings (March to September 1979)

SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-64

Summary Plot of Compaction Curves for Offsite Borrow (June to December 1979)

SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-65

Lateral Loading Diagrams for Nonrigid Walls SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-66

Lateral Loading Diagrams for Rigid Walls SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-67

Soil Profile and Finite Mesh Revetment A - Deepest Soil Deposit Cross Section Q-Q SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-68

Soil Profile and Finite Mesh Revetment A - Highest Section Cross Section R-R SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-69

Trial Wedges and Method of Settlement Analysis Revetment SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-70

Shear Modules at Low Strain Levels for Offsite Borrow and Tunnel Cuttings SEABROOK STATION UPDATED FINAL SAFETY ANALYSIS REPORT Figure 2.5-71