Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION REPORT Docket No. 71-9274 Model No. ABB-2901 Package Certificate of Compliance No. 9274 Revision No. 11

SUMMARY

By letter dated June 27, 2022, Westinghouse Electric Company, LLC. requested renewal of the Certificate of Compliance (CoC) No. 9274 for the Model No. ABB-2901 package. The Certificate of Compliance No. 9274, Revision No. 11, was renewed for five years.

EVALUATION By letter dated June 27, 2022, Westinghouse Electric Company, LLC. requested renewal of CoC No. 71-9274 for the Model No. ABB-2901 package. No changes in the package design, operating procedures, acceptance tests and maintenance program or contents of the package were requested. There are no changes to the Safety Analysis Report (SAR) Revision 4, submitted in supplement dated November 21, 2003, Ref: NFT-NRC-03-010.

The staff reviewed the documents referenced in the Certificate of Compliance, Revision No. 11, and determined that the package application was complete.

CONDITIONS Condition No. 11 has been revised to extend the CoC expiration date to September 30, 2027.

CONCLUSION Based on the statements and representations in the application, as supplemented, and the conditions listed above, the staff concludes that the Model No. ABB-2901 package design has been adequately described and evaluated and that these changes do not affect the ability of the package to meet the requirements of 10 CFR Part 71.

Issued with Certificate of Compliance No. 9274, Revision No. 11.