ML22243A248
| ML22243A248 | |
| Person / Time | |
|---|---|
| Site: | Hermes File:Kairos Power icon.png |
| Issue date: | 08/31/2022 |
| From: | Hastings P Kairos Power |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22243A247 | List: |
| References | |
| KP-NRC-2208-014 | |
| Download: ML22243A248 (2) | |
Text
KPNRC2208014
KairosPowerLLC
www.kairospower.com 707WTowerAve,SuiteA 5201HawkingDrSE,UnitA 2115RexfordRd,Suite325 Alameda,CA94501 Albuquerque,NM87106 Charlotte,NC28211
August31,2022 DocketNo.507513
USNuclearRegulatoryCommission ATTN:DocumentControlDesk Washington,DC205550001
Subject:
KairosPowerLLC ResponsetoNRCRequestforAdditionalInformation348and339
References:
- 1. Letter,KairosPowerLLCtoDocumentControlDesk,SubmittalofthePreliminary SafetyAnalysisReportfortheKairosPowerFluorideSaltCooled,HighTemperature NonPowerReactor(Hermes),September29,2021(ML21272A376)
- 2. Email,NuclearRegulatoryCommissionBenjaminBeasleytoDarrellGardner,Drew Peebles,JimTomkins,andMartyBryanFinalRAI348onShutdownRodReliability andDefenseinDepthAugust8,2022(ML22227A180)
- 3. Email,NuclearRegulatoryCommissionBenjaminBeasleytoDarrellGardner,Drew Peebles,JimTomkins,andMartyBryanNRCFinalRequestforAdditional Information339forHermesConstructionPermitApplicationRegardingInspectionof VesselInternalsandtheNaturalCirculationFlowPathAugust8,2022 (ML22230D076)
InSeptember2021,KairosPowersubmittedaPreliminarySafetyAnalysisReport(PSAR)(Reference1)as partoftheConstructionPermitApplication(CPA)fortheHermesnonpowerreactor.OnAugust8,2022, theNuclearRegulatoryCommissiontransmittedRequestsforAdditionalInformation(RAI)348andRAI 339(Reference2and3,respectively).Enclosure1providesKairosPowersresponsetoRAI348and providestheresponsetoRAI339.KairosPowerrequestsNRCreviewoftheseresponsesas partofthecontinuedreviewoftheHermesCPA.
Ifyouhaveanyquestionsorneedanyadditionalinformation,pleasecontactNicoleSchlichting schlichting@kairospower.comor(980)2159252,orDarrellGardneratgardner@kairospower.comor (704)7691226.
Sincerely,
PeterHastings,PE VicePresident,RegulatoryAffairsandQuality
KPNRC2208014 Page2
Enclosures:
- 1) ResponsetoNRCRequestforAdditionalInformation348
- 2) ResponsetoNRCRequestforAdditionalInformation339
xc(w/enclosure):
WilliamKennedy,ActingChief,NRRAdvancedReactorLicensingBranch BenjaminBeasley,ProjectManager,NRRAdvancedReactorLicensingBranch EdwardHelvenston,ProjectManager,NRRAdvancedReactorLicensingBranch SamuelCuadradodeJesus,ProjectManager,NRRAdvancedReactorLicensingBranch