SMR, LLC Preapplication Meeting Materials for August 31, 2022 (Project No. 99902049)
ML22236A529
Person / Time
Site: 99902049
Issue date: 08/24/2022
From: Hawkins J
Holtec, SMR
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
160-USNRC-015
Download: ML22236A529 (11)


Text

SMR, LLC. A Holtec International Company Krishna P. Singh Technology Campus,1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Transmittal No. 160-USNRC-015 Page 1 of 1 August 24, 2022 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

SMR, LLC Preapplication Meeting Materials for August 31, 2022 (Project No.

99902049)

SMR, LLC is pleased to submit presentation materials (Enclosure 1) for a preapplication meeting regarding loss-of-coolant analyses to support the construction permit application for the SMR-160 design on August 31, 2022.

If you have any questions or require any additional information, please contact Justin Hawkins, SMR-160 Director of Licensing, at j.hawkins@holtec.com, (O) 856-797-0900 x3452, or (C) 609-941-5765.

Respectfully, Justin Hawkins Director of Licensing, SMR, LLC

Enclosure:

1. SMR, LLC Preapplication Meeting Presentation Materials for August 31, 2022 CC:

T. Marcille (SMR, LLC, Vice President of Reactor Technologies)

J. Fleming (Holtec International, LLC, Vice President of Licensing, Regulatory Affairs &

PSA R. Trotta (SMR, LLC, Director of SMR-160)

M. Dudek (USNRC, DNRL, NRLB, Branch Chief)

C. Lauron (USNRC, DRNL, NRLB, Senior Project Manager G. Cranston (USNRC, DRNL, NRLB, Senior Project Manager)

Digitally signed by Justin Hawkins DN: cn=Justin Hawkins, c=US, o=U.S. Government, ou=External

Partners, email=j.hawkins@holtec.com Date: 2022.08.24 12:14:14 -04'00' Justin Hawkins

www.holtec.com NRC Public Meeting Regarding SMR-160 Licensing Questions - LOCA August 31, 2022 Holtecs SMR-160 Technology Safe, Secure, Reliable, Flexible, Economical Clean Energy to Support the Worlds Energy Needs

www.holtec.com l Page 2 Discuss with the NRC staff questions, and the context for these questions, that the SMR-160 licensing group has concerning applicable LBLOCA regulations, definitions, guidance, and previous RAIs on LTR HI-2201064 Receive feedback from the NRC staff on the questions, context, and answers/NRC positions Purpose

www.holtec.com l Page 3 Is the term design-basis accident (DBA) defined in NRC regulations?

The NRC website defines DBA as a postulated accident that a nuclear facility must be designed and built to withstand without loss to the systems, structures, and components necessary to ensure public health and safety.

We are trying to understand the relationship between the terms postulated and design-basis accident (DBA).

Question #1 Context

www.holtec.com l Page 4 Is the term beyond DBA (BDBA) defined in NRC regulations?

The NRC website defines BDBAs as This term is used as a technical way to discuss accident sequences that are possible but were not fully considered in the design process because they were judged to be too unlikely. (In that sense, they are considered beyond the scope of design-basis accidents that a nuclear facility must be designed and built to withstand.) As the regulatory process strives to be as thorough as possible, "beyond design-basis" accident sequences are analyzed to fully understand the capability of a design.

We are trying to understand the NRCs threshold for transitioning from DBA space to BDBA space.

Question #2 Context

www.holtec.com l Page 5 Loss of coolant accidents (LOCAs) are defined in the introduction to 10 CFR 50 App A as LOCAs mean those postulated accidents that result from the loss of reactor coolant at a rate in excess of the capability of the reactor coolant makeup system from breaks in the reactor coolant pressure boundary, up to and including a break equivalent in size to the double-ended rupture of the largest pipe of the reactor coolant system.

LOCAs is also defined in 10 CFR 46(c)(1) as hypothetical accidents that would result from the loss of reactor coolant, at a rate in excess of the capability of the reactor coolant makeup system, from breaks in pipes in the reactor coolant pressure boundary up to and including a break equivalent in size to the double-ended rupture of the largest pipe in the reactor coolant system. Are the terms postulated and hypothetical interchangeable in the definition of a LOCA?

We are trying to understand the relationship between the words in the definition of a LOCA and the words in the definitions of DBA and BDBA. Understanding the link will help us inform any potential exemption or exclusion from the LOCA requirements based on our design.

Question #3 Context

www.holtec.com l Page 6 Do the postulated events (such as accidents or pipe ruptures) discussed in the introduction to the GDCs, GDC 4, and 50.46, only include design basis events, or do they include both design basis and beyond design basis events?

Similar to the first three questions, we are seeking to understand the link between the term postulated and design basis. (If an event or accident is postulated then is that design basis space only )

Question #4 Context

www.holtec.com l Page 7 RAI 9832 states that Special circumstances may be justified to exclude postulating a LOCA at the specified locations from the design basis if Holtec can provide appropriate justification and conservative acceptance criteria that demonstrates a sufficiently low likelihood of failure at the subject locations with acceptably low consequences. Excluding postulating a break from the design basis and/or design basis accident analyses entirely would, in part, require meeting the minimum necessary for exclusion of the dynamic effects and additional considerations that demonstrate that the probability of fluid system piping rupture is sufficiently low (i.e., beyond extremely low) to determine that reasonable assurance of adequate protection is provided.

Why would Special circumstances (exemption) be necessary, in this case, if it could be proven that the probability of a break at a specified location was sufficiently low (i.e., beyond extremely low)? Wouldnt this sufficiently low determination designate a break at this location as a BDBE?

We are trying to determine the relationship between extremely low, sufficiently low, DBE and BDBE. If BDBE, do LOCA rules apply?

Question #5 Context

www.holtec.com l Page 8 Has an exemption ever been approved for GDC 35 and/or 10 CFR 50.46, specifically related to postulated LOCA break sizes or loss of coolant rates?

We are trying to determine if the NRC has ever considered an exemption request involving LOCA break sizes based in part on postulated breaks in certain locations being of sufficiently low likelihood.

Question #6 Context

www.holtec.com l Page 9 How do prior RAI histories, such as on Licensing Topical Reports, affect or relate to future applications related to the same technology?

For example, do RAIs 9832, 9843, and 9846 have any practical bearing or relation to a future Construction Permit Application for an SMR-160?

We would like to understand how our past attempt at justifying a potential exclusion from the LOCA rules will impact our future attempts at potentially justifying an exemption to the LOCA rules.

Question #7 Context

www.holtec.com l Page 10 Additional Questions and Follow-up Discussions Regarding This Topic