ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Braidwood Date of Examination:
5/18/20 Examination Level: RO SRO Operating Test Number:
19-1 NRC Administrative Topic (see Note)
Type Code*
Describe activity to be performed Conduct of Operations R, D R-102: Perform a QPTR Calculation without the Plant Process Computer K/A - GEN2.1.7 Importance - 4.4 Conduct of Operations R, D R-113: Perform 1BwOS RF-1, CONTAINMENT FLOOR DRAIN MONITORING SYSTEM NON-ROUTINE SURVEILLANCE K/A - GEN2.1.19 Importance - 3.9 Equipment Control R, D R-204: Identify Leak Isolation Points from Station Mechanical Drawings K/A - GEN2.2.41 Importance - 3.5 Radiation Control N/A N/A Emergency Plan R, M R-406: Perform NARS Form Transmittal for an ALERT (NARS Phone Failure)
K/A - GEN2.4.43 Importance - 3.2 NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes and Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)
(N)ew or (M)odified from bank ( 1)
(P)revious 2 exams ( 1, randomly selected)
ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Braidwood Date of Examination:
5/18/20 Examination Level: RO SRO Operating Test Number:
19-1 NRC Administrative Topic (see Note)
Type Code*
Describe activity to be performed Conduct of Operations R, D S-103: Call Out for Shift Staffing K/A - GEN2.1.5 Importance - 3.9 Conduct of Operations R, D S-111: Review and Approve Reactivity Change K/A - GEN2.1.43 Importance - 4.3 Equipment Control R, D S-202: Initiate a LCOAR (1B SX Pump)
K/A - GEN2.2.23 Importance - 4.6 Radiation Control R, D, P S-300: Review and Approve Containment Release K/A - GEN2.3.6 Importance - 3.8 Emergency Plan R, M S-410: Prepare and Approve NARS Form (General Emergency)
K/A - GEN2.4.38 Importance - 4.4 NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes and Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)
(N)ew or (M)odified from bank ( 1)
(P)revious 2 exams ( 1, randomly selected)