Text
This overview white paper is being released to support ongoing public discussions concerning the development of preliminary proposed rule language. This white paper has not been subject to complete NRC management or legal review, and its contents should not be interpreted as official agency positions. The NRC staff continues to work on the preliminary proposed rule language described in this document and continues to welcome public participation in these the rulemaking activities.
Part 53 Framework B Development Process and Provisions Overview The Nuclear Regulatory Commission (NRC) staff is developing optional regulatory frameworks to support eventual licensing of commercial nuclear plants through the proposed addition of a new part (Part 53) in Title 10 of the Code of Federal Regulations (10 CFR).1 The existing regulatory frameworks in 10 CFR Part 50 (Part 50) and 10 CFR Part 52 (Part 52) are currently being used for licensing new reactor technologies, but they were developed largely to accommodate the design and licensing of large, light-water reactors (LWRs). Part 53 would provide technology-inclusive regulations using methods of evaluation that are flexible and practicable for application to a variety of advanced reactor technologies, such as high-temperature gas and molten salt reactors. This would, in turn, help to reduce the need for non-LWR applicants to apply exemptions from certain existing LWR-specific requirements.
Preliminary proposed Part 53 language includes two distinct licensing framework options:
Framework A: Requirements would support an iterative approach to design and licensing where a Probabilistic Risk Assessment (PRA) is used in a leading manner.
Functional design criteria informed by a PRA are established to ensure that high-level safety and design requirements are satisfied. Framework A leverages many of the principles developed as part of the licensing modernization project as outlined in Nuclear Energy Institute Report 18-04,2 and NRC Regulatory Guide (RG) 1.233.3 Framework B: Requirements would support a traditional approach to design and licensing where deterministic safety analyses are complemented by risk insights; risk insights may also be used to confirm the results of traditional safety analyses. Principal design criteria are established in the initial stages of design and licensing and subsequent design activities are performed to ensure that these criteria are met.
Framework B also provides for the optional use of an Alternate Evaluation for Risk Insights (AERI) approach if certain criteria are satisfied to demonstrate that the bounding accident of such a facility would be of very low consequence.
1 This rulemaking was initiated, in part, in response to Congressional direction in the Nuclear Energy Innovation and Modernization Act, Pub. L. No. 115-439, § 103(a)(4), 132 Stat. 5565, 5572 (Jan. 14, 2019)
(codified at 42 U.S.C. § 2133 note).
2 Nuclear Energy Institute Technical Report 18-04, Revision 1. Risk-Informed Performance-Based Technology Inclusive Guidance for Non-Light Water Reactor Licensing Basis Development. August 2019 (ML19241A336).
3 Regulatory Guide (RG) 1.233, Revision 0. Guidance for a Technology-Inclusive, Risk-Informed, and Performance-Based Methodology to Inform the Licensing Basis and Content of Applications for Licenses, Certifications, and Approvals for Non-Light Water Reactors. June 2020 (ML20091L698).
Framework A preliminary proposed rule language development is largely complete. The second consolidated iteration of preliminary proposed rule language for Framework A was issued in May 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22125A000).
The NRC staff is preparing a consolidated draft proposed rule package with both frameworks to be provided to the Commission in February 2023. In the interim, the NRC staff continues to provide opportunities for stakeholders to provide feedback and comments on preliminary proposed rule language4 and supports additional stakeholder interactions through public meetings.
Background
Framework B was developed in response to stakeholder feedback regarding the need for additional flexibility in the use of PRA in Part 53. Framework B development was also motivated by stakeholder feedback suggesting that some reactor vendors may initially pursue international markets where licensing frameworks are informed by international safety standards and guidelines that more closely align with traditional paradigms in Part 50 and Part 52. Therefore, an internationally licensed design could subsequently be licensed domestically under a traditional framework, such as Framework B, without the need for major changes to the design approach.
Efforts to develop a traditional licensing framework in Part 53 began in mid-to late-2021 with the Part 5X effort which proposed technology-inclusive alternatives to some of the technical requirements in Parts 50 and 52. The initial iteration of the Part 5X rule text was included within the Part 53 consolidated draft preliminary proposed rule text package issued in February 2022 (ADAMS Accession No. ML22024A066). The Part 5X rule text, including feedback received on the Part 5X rule text during stakeholder interactions in 2021, was leveraged to develop certain Framework B technical content of application requirements. For example, the accident analysis and initiating event requirements in paragraph § 53.4730(a)(5) of the draft preliminary proposed rule text was informed by the Part 5X effort.
Development Methodology The NRC staff employed the following approach for developing Framework B requirements:
Adopt Framework A requirements when the Framework A requirements are independent of the analysis methodology (e.g., decommissioning).
o The NRC staff used direct cross-references to Framework A, where possible.
o Where direct cross-references could not be used, Framework A provisions were copied to Framework B with updated internal cross-references, terminology, etc.
Assess if existing requirements in Parts 50 and 52 are technology inclusive. If so, adopt them directly by copying the existing requirements into Framework B. In some instances, provisions from Parts 50 and 52 were not copied into Framework B, but were used by 4 For information on how to submit comments go to https://www.regulations.gov and search for Docket ID NRC-2019-0062 drafting conforming changes in the existing requirements and including a reference to these requirements in Framework B.
Develop unique, technology-inclusive requirements corresponding, where appropriate, to existing requirements in Parts 50 and 52. Consider state-of-practice technical and policy initiatives and, as appropriate and consistent with Commission policy, approaches used in international standards.
A table summarizing the results of this development process, including the source of Framework B requirements and reason for deviations from the source, as applicable, is provided in. Enclosure 1 reveals that a majority of Framework B preliminary proposed rule language is derived from Framework A or Parts 50 and 52. The NRC staff notes that there are instances where Frameworks A and B are intended to be identical or similar, but may have diverged slightly due to the timing between when the most recent iteration of each framework was released. These deviations will be reconciled when the frameworks are merged.
Structure Like Framework A, Framework B was developed to establish a standalone set of requirements covering the entire lifecycle of a commercial nuclear plant. Therefore, Framework A was used as a starting point for establishing the structure of Framework B. As shown in Table 1, Framework A and B structures are largely parallel.
Table 1: Part 53 Organization Subpart Title Framework A Subpart Framework B Subpart General Provisions Subpart A (Common)
Technology-Inclusive Safety Requirements Subpart B Note (1)
Design and Analysis Requirements Subpart C Siting Requirements Subpart D Note (2)
Definitions Note (3)
Subpart N Construction and Manufacturing Requirements Subpart E Subpart O Requirements for Operation Subpart F Subpart P Decommissioning Requirements Subpart G Subpart Q Licenses, Certifications, and Approvals Subpart H Subpart R Maintaining and Revising Licensing Basis Information Subpart I Subpart S Reporting and Other Administrative Requirements Subpart J Subpart T Quality Assurance Criteria Subpart K Subpart U Notes:
(1) Framework B does not include separate subparts for safety and design requirements. These are largely captured by the requirements in Subpart R in a manner similar to how technical requirements are captured for the various application types in Parts 50 and 52 as part of the technical content of application requirements for a given application type.
(2) Framework B does not include a separate subpart for siting requirements. The siting requirements in 10 CFR Part 100 are used instead, consistent with the treatment of siting in Parts 50 and 52.
(3) The most recent iteration of Framework A issued in May 2022 does not include a separate subpart for framework-specific definitions. It is expected that definitions specific to Framework A will be included within an existing Framework A subpart as the preliminary proposed rule language is further refined.
Subpart A: General Provisions Provides a scope and purpose statement, definitions of terms common to Frameworks A and B, and other provisions common to both frameworks (e.g., written communications, employee protection, specific exemptions).
Subpart N: Definitions Provides definitions that are unique to Framework B.
Subpart O: Construction and Manufacturing Requirements Provides requirements regarding construction and manufacturing activities; requirements are consistent with Framework A Subpart E except for internal references.
Subpart P: Requirements for Operation Provides requirements regarding plant operations, including plant personnel, maintenance, and programs. The structure of Subpart P parallels Framework A Subpart F in with some exceptions. These exceptions include certain programmatic requirements derived from the traditional licensing frameworks in Parts 50 and 52 (e.g., assessing maintenance effectiveness, environmental qualification of electrical equipment).
Subpart Q: Decommissioning Requirements Provides decommissioning requirements that are consistent with Framework A Subpart G, except for internal references.
Subpart R: Licenses, Certifications, and Approvals Provides design and licensing requirements for the various application types (early site permit, standard design approval, design certification, manufacturing license, construction permit, operating license, and combined license). Subpart R is analogous to Framework A Subpart H, but includes many of the technical requirements foundational and unique to Framework B (e.g.,
accident analyses, risk evaluations). For additional information see the Technical Requirements section below.
Subpart S: Maintaining and Revising Licensing Basis Information Provides requirements for maintaining licensing basis information and is structured identically to Subpart I in Framework A, with some exceptions. Certain requirements have been derived from Parts 50 and 52 (e.g., changes to a facility as described in the final safety analysis report without prior NRC approval) or adapted to account for Framework B-specific features (e.g.,
maintenance of a risk evaluation to include AERI).
Subpart T: Reporting and Other Administrative Requirements Provides reporting and administrative requirements that are analogous to Subpart J in Framework A, with some exceptions. Certain provisions were adapted from Part 50 and 52 to account for the framework-specific approaches to structures, systems, and components (SSCs) classification (e.g., immediate notification requirements from § 50.72 and licensee event reports from § 50.73).
Subpart U: Quality Assurance Criteria Provides quality assurance requirements for the design, manufacture, construction, and operation of certain SSCs. Subpart U is structured similar to Framework A Subpart K, and as Subpart K, the criteria have been sourced from Part 50 Appendix B.
Technical Requirements In contrast to the structure of technical content of application requirements in Part 50 and 52, Subpart R features a consolidated listing of technical requirements in § 53.4730 that are later referenced, as appropriate, in application-specific sections. The requirements in § 53.4730 are largely derived from the technical content of application requirements for a combined license (COL) application in § 52.79 because these requirements generally encompass the requirements for other application types. The following example illustrates how the Framework B approach compares to the organization of technical content of application requirements in Parts 50 and 52.
Design Certification (DC) and COL applicants under Part 52 are required to provide an analysis and description of the equipment and systems for combustible gas control by § 52.47(a)(12) and § 52.79(a)(8), respectively. The requirements in each of these two paragraphs in Part 52 are identical. Framework B includes a singular, identical, combustible gas control requirement in
§ 53.4730(a)(7) that is referenced in the technical content of application requirements for a DC and COL in § 53.4839 and § 53.5016, respectively.
A matrix summarizing § 53.4730 technical requirements referenced by each application type is provided in Enclosure 2.
Alternate Evaluation for Risk Insights (AERI)
The NRC staff recognized that the broad spectrum for which applicants may eventually pursue licensing under Framework B could include facilities that would have maximum accidents of very low consequence (e.g., low power microreactors). Considering this potential, the NRC staff has proposed an AERI approach for developing risk insights that would support licensing of these facilities. The AERI approach permits the use of alternate methods for developing risk insights (e.g., qualitative approaches) in lieu of a PRA if an applicant can satisfy the criteria in subparagraph § 53.4730(a)(34)(ii). Applicants and licensees using the AERI approach would still be required to maintain alternate risk evaluations in accordance with the requirements of
§ 53.6052, similar to the requirements for maintaining a PRA that are currently applied to licensees under § 50.71(h).
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3)
Subpart N - Scope and Definitions 53.3010 Definition - Anticipated operational occurrence 10 CFR Part 50 Appendix A, with modifications Modifications made to acknowledge the use of the term in Framework B 53.3010 Definition - Design bases 10 CFR 50.2, with modifications Modifications replace functional goals with specific functions 53.3010 Definition - Reactor coolant pressure boundary 10 CFR 50.2, with modifications Modifications made to clarify that definition only applies to water-cooled reactors 53.3010 Definition - Safety-related SSCs 10 CFR 50.2, with modifications Definition from 50.2 for LWRs does not vary, new definition proposed for term as applied to non-LWRs Subpart O - Construction and Manufacturing Requirements 53.4100 Construction and manufacturing -
scope and purpose.
Part 53 Framework A (copies 53.600)
Not applicable 53.4105 Reporting of defects and noncompliance.
Part 53 Framework A (copies 53.605, with modifications; derived from 50.55(e))
Modifications made to cross-reference equivalent Framework B provisions 53.4110 Construction.
Part 53 Framework A (copies 53.610, with modifications; derived from 50.10)
Modifications made to cross-reference equivalent Framework B provisions 53.4110(a)
Management and control Part 53 Framework A (copies 53.4110(a), with modifications)
Modifications reference the technical requirements in Subpart R in lieu of those in Subparts B and C 53.4110(b)
Construction activities Part 53 Framework A (copies 53.4110(b), with modifications) and 10 CFR 50.34(a)(11)
Modifications made regarding provisions for construction involving multiple reactor unit requirements adapted from 50.34(a)(11) 53.4120 Manufacturing.
Part 53 Framework A (copies 53.620, with modifications)
Modifications made to reflect the scope of SSCs that must meet quality assurance requirements in Framework B
Subpart P - Requirements for Operation 53.4210 Maintenance, repair, and inspection programs.
10 CFR 50.65, with modifications Modifications to existing Part 50 requirements made to ensure technology-inclusiveness and maintain
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) equivalent scope of SSCs considered within the scope of 10 CFR 50.65 53.4213 Technical specifications.
10 CFR 50.36, with modifications Modifications to existing Part 50 requirements made to ensure technology-inclusiveness and maintain equivalent scope of SSCs in TSs 53.4215 Vibratory ground motion required shutdown.
Part 53 Framework A (copies 53.720) and 10 CFR 50.54(ff)
Not applicable 53.4220 General staffing, training, personnel qualifications, and human factors requirements.
Part 53 Framework A (copies 53.725), with modifications Adapted to Framework B. In general, a primary difference that spans the requirements of Framework B §§ 53.4220 through 53.4282 is that the certified operator provisions of Framework A are reserved. Beyond that, another key source of significant differences in comparison with Framework A stems from Framework B not including the provisions of Part 53 subparts B & C.
53.4222 Communications Part 53 Framework A (copies 53.726), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4224 Information Collection Requirements Part 53 Framework A (copies 53.727), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4226 Defining, fulfilling, and maintaining the role of personnel in ensuring safe operations.
Part 53 Framework A (copies 53.730), with modifications Omits certified operator provisions 53.4228 General exemptions.
Part 53 Framework A (copies 53.735), with modifications Omits certified operator provisions and ensures appropriate cross referencing 53.4230 Conditions for operations staffing for operating or combined licenses under this part.
Part 53 Framework A (copies 53.740), with modifications Omits certified operator staffing screening criteria and related certified operator provisions 53.4232 Medical requirements.
Part 53 Framework A (copies 53.745), with modifications Omits certified operator provisions.
53.4234 Violations.
Part 53 Framework A (direct reference to 53.750)
Not applicable
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4236 Criminal penalties.
Part 53 Framework A (copies 53.755), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4240 Operator licensing.
Part 53 Framework A (copies 53.760), with modifications Adapted to Framework B 53.4242 License requirements.
Part 53 Framework A (direct reference to 53.765)
Not applicable 53.4244 Completeness and accuracy of information.
Part 53 Framework A (direct reference to 53.770)
Not applicable 53.4246 Incapacitation because of disability or illness.
Part 53 Framework A (direct reference to 53.775)
Not applicable 53.4248 Applications for licensed operators.
Part 53 Framework A (direct reference to 53.780)
Not applicable 53.4250 Training program.
Part 53 Framework A (reference to 53.785), with modifications References to change control provisions are adapted to the relevant section of Framework B 53.4252 Conditions of licensed operator and senior licensed operator licenses.
Part 53 Framework A (direct reference to 53.790)
Not applicable 53.4254 Expiration and Renewal Part 53 Framework A (direct reference to 53.792)
Not applicable 53.4256 Issuance, modification, and revocation of licenses.
Part 53 Framework A (direct reference to 53.795)
Not applicable 53.4260 - 53.4279 Reserved.
Not applicable Not applicable 53.4280 Training and qualification of commercial nuclear plant personnel.
Part 53 Framework A (copies 53.835), with modifications Adapted to Framework B 53.4282 Training and qualification requirements.
Part 53 Framework A (direct reference to 53.840)
Not applicable 53.4300 Programs.
Part 53 Framework A (copies 53.840), with modifications Modifications made to align prefatory text with fundamental safety objectives in Framework B 53.4310 Radiation protection.
See below 53.4310(a)
Radiation protection.
Part 53 Framework A (copies 53.850(a)), with modifications Modifications made to cross-reference equivalent Framework B provisions and ensure compliance with entirety of 10 CFR Part 20.
53.4310(b)
Radiation protection.
Part 53 Framework A (copies 53.850(b)), with modifications, and 10 CFR 50.36a Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4310(c)
Radiation protection.
New requirement developed for consistency with existing Standard Technical Specifications and 10 CFR 50.36a requirements Establishes specific requirements for process control program through compliance with radioactive waste control provisions 53.4320 Emergency preparedness.
Part 53 Framework A (direct reference to 53.855)
Not applicable.
53.4330 Security programs.
Part 53 Framework A (copies 53.860), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4340 Quality assurance.
Part 53 Framework A (copies 53.865), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4350 Fire protection.
10 CFR 50.48, 10 CFR Part 50 Appendix R with modifications, NFPA-805 Technology-inclusive fire protection requirements that require applicant to define safe and stable state for their design and determine the safe shutdown functions to achieve and maintain safe and stable state; performance-based alternative provided in 53.4350(c) 53.4360 Inservice inspection/inservice testing.
See below 53.4360(a)
Inservice inspection/inservice testing for LWRs Reference to 10 CFR 50.55a (ISI and IST provisions only)
Not applicable 53.4360(b)
Inservice inspection/inservice testing for NLWRs Part 53 Framework A (direct reference to 53.880)
Not applicable 53.4380 Environmental qualification of electric equipment important to safety for nuclear power plants.
10 CFR 50.49, with modifications Modifications made to Part 50 requirements to ensure technology-inclusiveness 53.4390 Procedures and guidelines.
Part 53 Framework A (copies portions of 53.910),
with modifications Modifications made to address variances in design basis events and SSC classifications between frameworks 53.4400 Integrity assessment program Part 53 Framework A (53.870), with modifications Modifications made to accommodate SSC classification scheme used in Framework B; scope of SSCs derived from 10 CFR 53.4210
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4410 Primary containment leakage rate testing program.
10 CFR 50.54(o), with modifications Modifications made to cross-reference equivalent Framework B provisions Subpart Q - Decommissioning 53.4600 Scope and Purpose.
Part 53 Framework A (copies 53.1000), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4610 Financial assurance for decommissioning.
Part 53 Framework A (copies 53.1010), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4620 Cost estimates for required decommissioning funds.
Part 53 Framework A (copies 53.1020), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4630 Annual adjustments.
Part 53 Framework A (copies 53.1030), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4640 Financial instruments for decommissioning funds.
Part 53 Framework A (copies 53.1040), with modifications, and 10 CFR 50.75(e)
Modifications made to cross-reference equivalent Framework B provisions 53.4645 Financial management of decommissioning funds.
Part 53 Framework A (copies 53.1045), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4650 NRC oversight.
Part 53 Framework A (copies 53.1050) and 10 CFR 50.75(e)(2)
Not applicable 53.4660 Reporting and recordkeeping requirements.
Part 53 Framework A (copies 53.1060), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4670 Termination of license.
Part 53 Framework A (copies 53.1070), with modifications, and 10 CFR 50.82 Modifications made to cross-reference equivalent Framework B provisions 53.4680 Release of part of a commercial nuclear plant or site for unrestricted use.
Part 53 Framework A (copies 53.1080), with modifications, and 10 CFR 50.83 Modifications made to cross-reference equivalent Framework B provisions Subpart R - Licenses, Certifications, and Approvals 53.4700 Filing of application for licenses, certifications, or approvals; oath or affirmation.
Part 53 Framework A (copies 53.1100), with modifications, and 10 CFR 50.30 Modifications made to cross-reference equivalent Framework B provisions 53.4701 Requirement for license.
Part 53 Framework A (copies 53.1101), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4703 Combining applications.
Part 53 Framework A (copies 53.1103), with modifications, and 10 CFR 50.31 and 52.8 Modifications made to cross-reference equivalent Framework B provisions 53.4706 Elimination of repetition.
Part 53 Framework A (copies 53.1106), with modifications, and 10 CFR 50.32 Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4709 Contents of application; general information.
Part 53 Framework A (copies 53.1109), with modifications, and 10 CFR 50.33 Modifications made to cross-reference equivalent Framework B provisions 53.4712 Environmental conditions.
Part 53 Framework A (copies 53.1112), with modifications, and 10 CFR 50.36(b)
Modifications made to cross-reference equivalent Framework B provisions 53.4715 Agreement limiting access to Classified Information.
Part 53 Framework A (copies 53.1115), with modifications, and 10 CFR 50.37 Modifications made to cross-reference equivalent Framework B provisions 53.4718 Ineligibility of certain applicants.
Part 53 Framework A (copies 53.1118), with modifications, and 10 CFR 50.38 Modifications made to cross-reference equivalent Framework B provisions 53.4720 Exceptions and exemptions from licensing requirements Part 53 Framework A (copies 53.1120), with modifications, and 10 CFR 50.11 Modifications made to cross-reference equivalent Framework B provisions 53.4721 Public inspection of applications.
Part 53 Framework A (copies 53.1121), with modifications, and 10 CFR 50.39 Modifications made to cross-reference equivalent Framework B provisions 53.4724 Relationship between sections.
Part 53 Framework A (copies 53.1124), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4725 Standards for review.
See below 53.4725(a)
Common standards.
10 CFR 50.40, with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4725(b)
Additional standards for class 104 licenses.
10 CFR 50.41, with modifications Modifications made to limit scope of the review standard to potential Framework B applicants 53.4725(c)
Additional standards for class 103 licenses.
10 CFR 50.42, with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4725(d)
Additional standards and provisions affecting class 103 licenses and certifications for commercial power.
10 CFR 50.43, with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4730 General technical requirements.
See below 53.4730(a)(1)
Site safety analysis.
10 CFR 52.79(a)(1), with modifications Modifications made to support technology-inclusive rule text 53.4730(a)(2)
Facility description.
10 CFR 52.79(a)(2), with modifications Modifications made to support technology-inclusive rule text 53.4730(a)(3)
Kinds and quantities of radioactive materials.
10 CFR 52.79(a)(3), with modifications, 10 CFR 50.34a, and 10 CFR 20.1101(b)
Modifications made to reflect requirements in 10 CFR Subpart B for ALARA
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(4)
Design bases and principal design criteria 10 CFR 52.79(a)(4), with modifications Modifications made to support technology-inclusive rule text 53.4730(a)(5)
Initiating event and accident analysis See below 53.4730(a)(5)(i)
Initiating event and accident analysis - Requirement for analysis and evaluation 10 CFR 52.79(a)(5), with modifications Modifications made to support technology-inclusive rule text and accommodate new event classifications below 53.4730(a)(5)(ii)
Initiating event and accident analysis - DBA New technology-inclusive requirements for DBA analyses and SSC classification; 10 CFR 50.46 Modifications made to support technology-inclusive rule text, define acceptance criteria consistent with current rules and create new 50.46-like requirement; includes addition of bounding option 53.4730(a)(5)(iii)
Initiating event and accident analysis - AOO New requirement for AOOs that is consistent with current requirements to remain below Part 20 acceptance criteria and prevent event escalation Requirement is new but is based on other existing requirements (and includes a pointer to Part 20) and guidance for AOOs 53.4730(a)(5)(iv)
Initiating event and accident analysis - BDBEs New requirements for assessments and analyses for credible BDBEs in (A), requirement to provide design features or programmatic controls to mitigate these events in (B) (attempt to create technology-inclusive class of events such as SBO and ATWS)
Provides technology-inclusive requirements for important BDBEs and analysis requirements for other BDBEs, similar to international defense in depth requirements 53.4730(a)(5)(v)
Initiating event and accident analysis - severe accidents 10 CFR 52.79(a)(38), with modifications Modifications made to support technology-inclusive rule text 53.4730(a)(5)(vi)
Initiating event and accident analysis - chemical hazards Part 53 Framework A (53.440(k)), with modifications New requirement that was modified from Framework A for consistency with Framework B organization and analysis approach 53.4730(a)(6)
Fire protection.
10 CFR 52.79(a)(6) and (a)(40), with modifications Modifications reference back to analogous program and design requirements in subpart P
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(7)
Combustible gas control.
10 CFR 52.79(a)(8) and 10 CFR 50.44, by extension Not applicable 53.4730(a)(8)
Environmental qualification of electric equipment important to safety.
10 CFR 52.79(a)(10), with modifications, and 10 CFR 50.49, by extension Modifications reference back to analogous program requirements in subpart P. Split to accommodate the different amounts of information required for the various applications.
53.4730(a)(9)
Role of personnel.
10 CFR 52.79(a)(14) and 10 CFR 52.79(a)(34) with restructuring New requirement that maps back to analogous operational requirements in subpart P 53.4730(a)(10)
Maintenance rule.
10 CFR 52.79(a)(15), with modifications, and 10 CFR 50.65, by extension Modifications made to reference analogous program requirements in subpart P 53.4730(a)(11)
Effluent control 10 CFR 52.79(a)(16), 10 CFR 50.34a, and 10 CFR 20.1101(d), with modifications Modifications made to reference analogous program requirements in subpart P and address existing light-water-reactor requirements in 10 CFR Part 50, Appendix I for effluents 53.4730(a)(12)
Post-accident radiation monitoring and protection.
See below 53.4730(a)(12)(i)
Post-accident radiation monitoring and protection (TMI action item) 10 CFR 50.34(f)(2)(vii)
Not applicable 53.4730(a)(12)(ii)
Post-accident radiation monitoring and protection (TMI action item) 10 CFR 50.34(f)(2)(viii), with modifications Modifications made to acknowledge that the list referred to in the source reference does not exist in 10 CFR Appendix B nor has one been proposed for inclusion in Subpart U.
53.4730(a)(12)(iii)
Post-accident radiation monitoring and protection (TMI action item) 10 CFR 50.34(f)(2)(xv)
Not applicable 53.4730(a)(13)
Reserved.
Not applicable 53.4730(a)(14)
Earthquake engineering criteria.
10 CFR 52.79(a)(19), with modifications, and 10 CFR Part 50 Appendix S, by extension Modifications have been made to ensure technology-inclusiveness when referencing 10 CFR Part 50 Appendix S requirements
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(15)
Emergency plans 10 CFR 52.79(a)(21), with modifications Modifications made to cross-reference requirements in subpart P, which ultimately map back to Framework A (53.855) 53.4730(a)(16)
State and local government cooperation in emergency planning.
10 CFR 52.79(a)(22), with modifications Modifications made to reflect state-of-practice policy initiatives and align with Commissions Tribal Policy Statement (82 FR 2402) and the 2019 issuance of NUREG-0654/FEMA-REP-1, Revision 2, which encourages the involvement of Tribal governments in NRC activities (also see SECY-22-0001) 53.4730(a)(17)
Safety feature testing, analyses, operating experience, and prototypes.
10 CFR 52.79(a)(24) and 10 CFR 50.43(e), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4730(a)(18)
Quality assurance program.
See below 53.4730(a)(18)(i)
Quality assurance program (TMI action item) 10 CFR 50.34(f)(3)(iii), with modifications Modifications to limit applicability, consistent with existing requirements in 10 CFR 50.34(f) which limit applicability based on technical relevance 53.4730(a)(18)(ii)
Quality assurance program (TMI action item) 10 CFR 50.34(f)(3)(ii), with modifications Modifications to cross-reference subpart U instead of 10 CFR Part 50 Appendix B 53.4730(a)(18)(iii)
Quality assurance program (COL application req.)
10 CFR 52.79(a)(25), with modifications Modifications made to reference analogous program requirements in subpart U 53.4730(a)(19)
Organizational structure.
Not applicable 53.4730(a)(20)
Managerial and administrative controls.
See below 53.4730(a)(20)(i)
Managerial and administrative controls.
10 CFR 52.79(a)(27), with modifications
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(20)(ii)
Managerial and administrative controls (TMI action item) 10 CFR 50.34(f)(3)(vii), with modifications Modifications made to limit applicability consistent with existing provisions in 10 CFR 50.34(f) 53.4730(a)(21)
Preoperational testing and initial startup.
Not applicable 53.4730(a)(22)
Normal operations and maintenance.
Not applicable 53.4730(a)(23)
Technical specifications.
10 CFR 52.79(a)(30), with modifications and 10 CFR 50.36 Modifications made to reference technical specification requirements in subpart P and differentiate requirements for TSs between application types 53.4730(a)(24)
Fitness-for-duty programs.
10 CFR 52.79(a)(44) and 10 CFR Part 26, by extension Not applicable 53.4730(a)(25)
Multi-unit sites.
Not applicable 53.4730(a)(26)
Technical qualifications.
Not applicable 53.4730(a)(27)
Training program.
10 CFR 52.79(a)(33), with modifications Modifications made to reference analogous program requirements in subpart P 53.4730(a)(28)
Physical security program.
10 CFR 52.79(a)(35), with modifications Modifications made to reference analogous program requirements in subpart P 53.4730(a)(29)
Safeguards, security, and related training and qualifications.
10 CFR 52.79(a)(36), with modifications Modifications made to include an additional reference to 10 CFR 73.22 53.4730(a)(30)
Operating experience.
10 CFR 52.79(a)(37), with modifications Modifications limit applicability of this requirement to accommodate designs with limited operating experience 53.4730(a)(31)
Radiation protection program 10 CFR 52.79(a)(39), with modifications Modifications made to reference analogous program requirements in subpart P 53.4730(a)(32)
Criticality accident requirements.
10 CFR 52.79(a)(43), with modifications Modifications made to reference criticality accident and monitoring requirements in part 53 Framework A 53.440(m)
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(33)
Minimization of contamination.
10 CFR 52.79(a)(45) and 10 CFR 20.1406, by extension Not applicable 53.4730(a)(34)
Risk evaluations.
See below 53.4730(a)(34)(i)
Risk evaluations - PRA 10 CFR 52.79(a)(46), with modifications Modifications made to accommodate same requirement in Framework B; no technical changes 53.4730(a)(34)(ii)
Risk evaluations - AERI New alternative to meeting 53.4730(a)(34)(i)
Not applicable 53.4730(a)(35)
Aircraft impact assessment.
10 CFR 50.150(a) and (b), with modifications.
Modifications made to support technology-inclusive rule text 53.4730(a)(36)
Functional containment.
See below 53.4730(a)(36)(i)
Functional containment - NLWR New alternative developed for NLWRs consistent with policy in SECY-18-0096 Not applicable 53.4730(a)(36)(ii)
Functional containment - LWR Requirements developed by combining 10 CFR Part 50 Appendix J requirements with relevant TMI action items (10 CFR 50.34(f)(2)(xiv),
(f)(2)(xv), and (f)(3)(iv))
Modifications to TMI action items made to limit applicability, consistent with current requirements in 10 CFR 50.34(f), which are limited based on technical relevance 53.4730(a)(37)
Water-cooled reactor requirements.
See below 53.4730(a)(37)(i)
Emergency core cooling systems.
10 CFR 52.79(a)(5), with modifications, and 10 CFR 50.46 and 10 CFR 50.46a, by extension Modifications made to abbreviate language from existing requirement 53.4730(a)(37)(ii)
Codes and standards.
10 CFR 52.79(a)(11) and 10 CFR 50.55a, by extension Not applicable 53.4730(a)(37)(iii)
Pressurized thermal shock and fracture toughness requirements.
10 CFR 52.79(a)(7) and 10 CFR 50.60 and 10 CFR 50.61, by extension Not applicable 53.4730(a)(37)(iv)
Anticipated transients without scram.
10 CFR 52.79(a)(42) and 10 CFR 50.62, by extension Not applicable 53.4730(a)(37)(v)
Station blackout.
10 CFR 52.79(a)(9) and 10 CFR 50.63, by extension Not applicable 53.4730(a)(37)(vi)
Reactor vessel material surveillance.
10 CFR 52.79(a)(13) and 10 CFR Part 50 Appendix H, by extension Not applicable 53.4730(a)(37)(vii)
Containment leakage testing.
10 CFR 52.79(a)(12) and 10 CFR Part 50 Appendix J, by extension Not applicable 53.4730(a)(37)(viii)
Standard review plan evaluation.
Not applicable
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4730(a)(37)(ix)
Resolution of generic issues.
10 CFR 52.79(a)(20), with modifications Modifications to adopt corrections proposed in ongoing policy initiatives that recognize new classification scheme in NUREG-0933 53.4730(a)(37)(x)
LWR-specific Three Mile Island requirements.
See below 53.4730(a)(37)(x)(A)
LWR-specific Three Mile Island requirements.
Not applicable 53.4730(a)(37)(x)(B)
LWR-specific Three Mile Island requirements.
Not applicable 53.4730(a)(37)(x)(C)
LWR-specific Three Mile Island requirements.
Not applicable 53.4731 Risk-informed classification of structures, systems, and components 10 CFR 50.69, with modifications Modifications made to ensure technology-inclusiveness and reference equivalent provisions from Framework B 53.4740 Limited work authorizations.
Part 53 Framework A (copies 53.1130), with modifications, and 10 CFR 50.10 Modifications made to cross-reference equivalent Framework B provisions 53.4750 Early site permits.
Part 53 Framework A (copies 53.1140), with modifications, and 10 CFR 52.12 Modifications made to cross-reference equivalent Framework B provisions 53.4753 Filing of applications.
Part 53 Framework A (copies 53.1143), with modifications, and 10 CFR 52.15 Modifications made to cross-reference equivalent Framework B provisions 53.4754 Contents of applications for early site permits; general information.
Part 53 Framework A (copies 53.1144), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4756 Contents of applications for early site permits; technical information.
10 CFR 52.17, with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.4759 Review of applications.
Part 53 Framework A (copies 53.1149), with modifications, and 10 CFR 52.18 and 52.21 Modifications made to cross-reference equivalent Framework B provisions 53.4765 Referral to the Advisory Committee on Reactor Safeguards (ACRS).
Part 53 Framework A (copies 53.1155), with modifications, and 10 CFR 52.23 Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4768 Issuance of early site permit.
Part 53 Framework A (copies 53.1158), with modifications, and 10 CFR 52.24 Modifications made to cross-reference equivalent Framework B provisions 53.4771 Extent of activities permitted.
Part 53 Framework A (copies 53.1161), with modifications, and 10 CFR 52.25 Modifications made to cross-reference equivalent Framework B provisions 53.4774 Duration of permit.
Part 53 Framework A (copies 53.1164), with modifications, and 10 CFR 52.26 Modifications made to cross-reference equivalent Framework B provisions 53.4777 Limited work authorization after issuance of early site permit.
Part 53 Framework A (copies 53.1167), with modifications, and 10 CFR 52.27 Modifications made to cross-reference equivalent Framework B provisions 53.4780 Transfer of early site permit.
Part 53 Framework A (copies 53.1170), with modifications, and 10 CFR 52.28 Modifications made to cross-reference equivalent Framework B provisions 53.4783 Application for renewal.
Part 53 Framework A (copies 53.1173), with modifications, and 10 CFR 52.29 Modifications made to cross-reference equivalent Framework B provisions 53.4786 Criteria for renewal.
Part 53 Framework A (copies 53.1176), with modifications, and 10 CFR 52.31 Modifications made to cross-reference equivalent Framework B provisions 53.4789 Duration of renewal.
Part 53 Framework A (copies 53.1179), with modifications, and 10 CFR 52.33 Modifications made to cross-reference equivalent Framework B provisions 53.4792 Use of site for other purposes.
Part 53 Framework A (copies 53.1182), with modifications, and 10 CFR 52.35 Modifications made to cross-reference equivalent Framework B provisions 53.4795 Reporting of defects and noncompliance; revocation, suspension, modification of permits for cause.
Part 53 Framework A (copies 53.1185), with modifications, and 10 CFR 52.37 Modifications made to cross-reference equivalent Framework B provisions 53.4798 Finality of early site permit determinations.
Part 53 Framework A (copies 53.1188), with modifications, and 10 CFR 52.39 Modifications made to cross-reference equivalent Framework B provisions 53.4800 Standard design approvals.
Part 53 Framework A (copies 53.1200), with modifications, and 10 CFR 52.131 Modifications made to cross-reference equivalent Framework B provisions 53.4803 Filing of applications.
Part 53 Framework A (copies 53.1203), with modifications, and 10 CFR 52.135 Modifications made to cross-reference equivalent Framework B provisions 53.4806 Contents of applications for standard design approvals; general information.
Part 53 Framework A (copies 53.1206), with modifications, and 10 CFR 52.136 Modifications made to cross-reference equivalent Framework B provisions 53.4809 Contents of applications for standard design approvals; technical information.
10 CFR 52.137, with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) was not leveraged, update references to equivalent provisions in Framework B
53.4812 Review of applications.
Part 53 Framework A (copies 53.1212), with modifications, and 10 CFR 52.139 Modifications made to cross-reference equivalent Framework B provisions 53.4815 Referral to the Advisory Committee on Reactor Safeguards (ACRS).
Part 53 Framework A (copies 53.1215), with modifications, and 10 CFR 52.141 Modifications made to cross-reference equivalent Framework B provisions 53.4818 Staff approval of design.
Part 53 Framework A (copies 53.1218), with modifications, and 10 CFR 52.143 and 52.147 Modifications made to cross-reference equivalent Framework B provisions 53.4821 Finality of standard design approvals; information requests.
Part 53 Framework A (copies 53.1221), with modifications, and 10 CFR 52.145 Modifications made to cross-reference equivalent Framework B provisions 53.4830 Standard design certifications.
Part 53 Framework A (copies 53.1230), with modifications, and 10 CFR 52.41 Modifications made to cross-reference equivalent Framework B provisions 53.4833 Filing of applications.
Part 53 Framework A (copies 53.1233), with modifications, and 10 CFR 52.45 Modifications made to cross-reference equivalent Framework B provisions 53.4836 Contents of applications for standard design certifications; general information.
Part 53 Framework A (copies 53.1236), with modifications, and 10 CFR 52.46 Modifications made to cross-reference equivalent Framework B provisions 53.4839 Contents of applications for standard design certifications; technical information.
10 CFR 52.47, with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.4841 Contents of applications for standard design certifications; other application content.
Part 53 Framework A (copies 53.1241), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4842 Review of applications.
Part 53 Framework A (copies 53.1242), with modifications, and 10 CFR 52.48 and 52.51 Modifications made to cross-reference equivalent Framework B provisions 53.4845 Referral to the Advisory Committee on Reactor Safeguards (ACRS).
Part 53 Framework A (copies 53.1245), with modifications, and 10 CFR 52.53 Modifications made to cross-reference equivalent Framework B provisions 53.4848 Issuance of standard design certification.
Part 53 Framework A (copies 53.1248), with modifications, and 10 CFR 52.54 Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4851 Duration of certification.
Part 53 Framework A (copies 53.1251), with modifications, and 10 CFR 52.55 Modifications made to cross-reference equivalent Framework B provisions 53.4854 Application for renewal.
Part 53 Framework A (copies 53.1254), with modifications, and 10 CFR 52.57 Modifications made to cross-reference equivalent Framework B provisions 53.4857 Criteria for renewal.
Part 53 Framework A (copies 53.1257), with modifications, and 10 CFR 52.59 Modifications made to cross-reference equivalent Framework B provisions 53.4860 Duration of renewal.
Part 53 Framework A (copies 53.1260), with modifications, and 10 CFR 52.61 Modifications made to cross-reference equivalent Framework B provisions 53.4863 Finality of standard design certifications.
Part 53 Framework A (copies 53.1263), with modifications, and 10 CFR 52.63 Modifications made to cross-reference equivalent Framework B provisions 53.4870 Manufacturing licenses.
Part 53 Framework A (copies 53.1270), with modifications, and 10 CFR 52.151 Modifications made to cross-reference equivalent Framework B provisions 53.4873 Filing of applications.
Part 53 Framework A (copies 53.1273), with modifications, and 10 CFR 52.155 Modifications made to cross-reference equivalent Framework B provisions 53.4876 Contents of applications for manufacturing licenses; general information.
Part 53 Framework A (copies 53.1276), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4879 Contents of applications for manufacturing licenses; technical information.
10 CFR 52.157, with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.4882 Contents of applications for manufacturing licenses; other application content.
Part 53 Framework A (copies 53.1282), with modifications, and 10 CFR 52.158 Modifications made to cross-reference equivalent Framework B provisions 53.4885 Review of applications.
Part 53 Framework A (copies 53.1285), with modifications, and 10 CFR 52.159 Modifications made to cross-reference equivalent Framework B provisions 53.4886 Referral to ACRS.
Part 53 Framework A (copies 53.1286), with modifications, and 10 CFR 52.165 Modifications made to cross-reference equivalent Framework B provisions 53.4887 Issuance of a manufacturing license.
Part 53 Framework A (copies 53.1287), with modifications, and 10 CFR 52.167 Modifications made to cross-reference equivalent Framework B provisions 53.4888 Finality of manufacturing licenses; information requests.
Part 53 Framework A (copies 53.1288), with modifications, and 10 CFR 52.171 Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4891 Duration of manufacturing licenses.
Part 53 Framework A (copies 53.1291), with modifications, and 10 CFR 52.173 Modifications made to cross-reference equivalent Framework B provisions 53.4893 Transfer of manufacturing licenses.
Part 53 Framework A (copies 53.1293), with modifications, and 10 CFR 52.175 Modifications made to cross-reference equivalent Framework B provisions 53.4895 Renewal of manufacturing licenses.
Part 53 Framework A (copies 53.1295), with modifications, and 10 CFR 52.177 and 52.179 Modifications made to cross-reference equivalent Framework B provisions 53.4900 Construction permits.
Part 53 Framework A (copies 53.1300), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4906 Contents of applications for construction permits; general information.
Part 53 Framework A (copies 53.1306), with modifications, and 10 CFR 50.33 Modifications made to cross-reference equivalent Framework B provisions 53.4909 Contents of applications for construction permits; technical information.
10 CFR 50.34(a), with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.4912 Contents of applications for construction permits; other application content.
Part 53 Framework A (copies 53.1312), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4915 Review of applications.
Part 53 Framework A (copies 53.1315), with modifications, and 10 CFR 52.81, 50.58, and 52.85 Modifications made to cross-reference equivalent Framework B provisions 53.4918 Finality of referenced NRC approvals, licenses and certifications.
Part 53 Framework A (copies 53.1318), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4924 Referral to the Advisory Committee on Reactor Safeguards (ACRS).
Part 53 Framework A (copies 53.1324), with modifications, and 10 CFR 50.58 and 52.87 Modifications made to cross-reference equivalent Framework B provisions 53.4927 Authorization to conduct limited work authorization activities.
Part 53 Framework A (copies 53.1327), with modifications, and 10 CFR 50.10(g)
Modifications made to cross-reference equivalent Framework B provisions 53.4930 Exemptions, departures, and variances.
Part 53 Framework A (copies 53.1330), with modifications, and 10 CFR 50.11, 52.93, 52.39(d)
Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4933 Issuance of construction permits.
Part 53 Framework A (copies 53.1333), with modifications, and 10 CFR 30.35, 50.36(b),
52.97(c), and 50.35(b)
Modifications made to cross-reference equivalent Framework B provisions 53.4936 Finality of construction permits.
Part 53 Framework A (copies 53.1336), with modifications, and 10 CFR 50.35(b) and (c)
Modifications made to cross-reference equivalent Framework B provisions 53.4939 Construction activities.
Part 53 Framework A (copies 53.1339), with modifications, and 10 CFR 53.610 Modifications made to cross-reference equivalent Framework B provisions 53.4942 Duration of construction permit.
Part 53 Framework A (copies 53.1342), with modifications, and 10 CFR 50.55(a) and (b)
Modifications made to cross-reference equivalent Framework B provisions 53.4945 Transfer of construction permits.
Part 53 Framework A (copies 53.1345), with modifications, and 10 CFR 50.80 Modifications made to cross-reference equivalent Framework B provisions 53.4948 Termination of construction permits. Part 53 Framework A (copies 53.1348), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4960 Operating licenses.
Part 53 Framework A (copies 53.1360), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4966 Contents of applications for operating licenses; general information.
Part 53 Framework A (copies 53.1366), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4969 Contents of applications for operating licenses; technical information.
10 CFR 50.34(b) with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.4972 Contents of applications for operating licenses; other application content.
Part 53 Framework A (copies 53.1372), with modifications, and 10 CFR 51.50, 53.710(a), and 53.710(b)
Modifications made to cross-reference equivalent Framework B provisions 53.4975 Review of applications.
Part 53 Framework A (copies 53.1375), with modifications, and 10 CFR 52.81, 50.34, and 52.85 Modifications made to cross-reference equivalent Framework B provisions 53.4981 Referral to the Advisory Committee on Reactor Safeguards (ACRS).
Part 53 Framework A (copies 53.1381), with modifications, and 10 CFR 50.58 and 52.87 Modifications made to cross-reference equivalent Framework B provisions 53.4984 Exemptions, departures, and variances.
Part 53 Framework A (copies 53.1384), with modifications, and 10 CFR 52.93 and 52.39(d)
Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.4987 Issuance of operating licenses.
Part 53 Framework A (copies 53.1387), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.4990 Finality of operating licenses.
Part 53 Framework A (copies 53.1390), with modifications, and 10 CFR 52.98(a)
Modifications made to cross-reference equivalent Framework B provisions 53.4996 Duration of operating license.
Part 53 Framework A (copies 53.1396), with modifications, and 10 CFR 50.51 Modifications made to cross-reference equivalent Framework B provisions 53.4999 Transfer of an operating license.
Part 53 Framework A (copies 53.1399), with modifications, and 10 CFR 52.105 Modifications made to cross-reference equivalent Framework B provisions 53.5002 Application for renewal.
Part 53 Framework A (copies 53.1402), with modifications, and 10 CFR 52.107 Modifications made to cross-reference equivalent Framework B provisions 53.5005 Continuation of an operating license.
Part 53 Framework A (copies 53.1405), with modifications, and 10 CFR 50.51 Modifications made to cross-reference equivalent Framework B provisions 53.5010 Combined licenses.
Part 53 Framework A (copies 53.1410), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.5013 Contents of applications for combined licenses; general information.
Part 53 Framework A (copies 53.1413), with modifications, and 10 CFR 52.77 Modifications made to cross-reference equivalent Framework B provisions 53.5016 Contents of applications for combined licenses; technical information.
10 CFR 52.79, with modifications Modifications made to adopt equivalent technical requirements in section 53.4730 and, where section 53.4730 was not leveraged, update references to equivalent provisions in Framework B
53.5019 Contents of applications for combined licenses; other application content.
Part 53 Framework A (copies 53.1419), with modifications, and 10 CFR 52.80 Modifications made to cross-reference equivalent Framework B provisions 53.5022 Review of applications.
Part 53 Framework A (copies 53.1422), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.5025 Finality of referenced NRC approvals.
Part 53 Framework A (copies 53.1425), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.5031 Referral to the Advisory Committee on Reactor Safeguards.
Part 53 Framework A (copies 53.1431), with modifications, and 10 CFR 52.87 Modifications made to cross-reference equivalent Framework B provisions 53.5034 Authorization to conduct limited work authorization activities.
Part 53 Framework A (copies 53.1434), with modifications, and 10 CFR 52.91 Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.5037 Exemptions and variances.
Part 53 Framework A (copies 53.1437), with modifications, and 10 CFR 52.93 Modifications made to cross-reference equivalent Framework B provisions 53.5040 Issuance of combined licenses.
Part 53 Framework A (copies 53.1440), with modifications, and 10 CFR 52.97 Modifications made to cross-reference equivalent Framework B provisions 53.5043 Finality of combined licenses.
Part 53 Framework A (copies 53.1443), with modifications, and 10 CFR 52.98 Modifications made to cross-reference equivalent Framework B provisions 53.5046 Construction activities.
Part 53 Framework A (copies 53.1446), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.5049 Inspection during construction.
Part 53 Framework A (copies 53.1449), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.5052 Operation under a combined license.
Part 53 Framework A (copies 53.1452), with modifications, and 10 CFR 52.103 Modifications made to cross-reference equivalent Framework B provisions 53.5055 Duration of combined license.
Part 53 Framework A (copies 53.1455), with modifications, and 10 CFR 52.104 Modifications made to cross-reference equivalent Framework B provisions 53.5056 Transfer of a combined license.
Part 53 Framework A (copies 53.1456), with modifications, and 10 CFR 52.105 Modifications made to cross-reference equivalent Framework B provisions 53.5058 Application for renewal.
Part 53 Framework A (copies 53.1458), with modifications, and 10 CFR 52.107 Modifications made to cross-reference equivalent Framework B provisions 53.5061 Continuation of combined license.
Part 53 Framework A (copies 53.1461), with modifications, and 10 CFR 52.109 Modifications made to cross-reference equivalent Framework B provisions 53.5070 Standardization of nuclear power plant designs: licenses to construct and operate nuclear power reactors of identical design at multiple sites.
Part 53 Framework A (copies 53.1470), with modifications, and Appendix N of Parts 50 and 52 Modifications made to cross-reference equivalent Framework B provisions Subpart S - License Maintenance 53.6000 Licensing basis information.
Part 53 Framework A (copies 53.1500), with modifications Modifications made to clarify applicability under Framework B 53.6002 Specific terms and conditions of licenses Part 53 Framework A (copies 53.1502), with modifications Modifications made to clarify applicability under Framework B 53.6005 Changes to licensing basis information requiring prior NRC approval.
Part 53 Framework A (copies 53.1505), with modifications Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.6010 Application for amendment of license.
Part 53 Framework A (copies 53.1510), with modifications, 10 CFR 50.90 and 10 CFR 50.91(a)(1)
Modifications made to reconcile differences between analysis requirements in Frameworks A and B to support a license amendment (Framework B aligned more closely with existing 10 CFR Part 50 provisions) 53.6015 Public notices; state consultation.
Part 53 Framework A (copies 53.1515), with modifications, and 10 CFR 50.91 Modifications made to cross-reference equivalent Framework B provisions 53.6020 Issuance of amendment.
Part 53 Framework A (copies 53.1520), with modifications, and 10 CFR 50.92 Modifications made to cross-reference equivalent Framework B provisions 53.6025 Revising certification information within a design certification rule.
Part 53 Framework A (copies 53.1525), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6030 Revising design information within a manufacturing license.
Part 53 Framework A (copies 53.1530), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6035 Amendments during construction.
Part 53 Framework A (copies 53.1535), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6040 Updating licensing basis information and determining the need for NRC approval 10 CFR 50.59, with modifications Modifications include eliminating the term Final Hazards Summary Report (legacy term) and inclusion of cross-references to equivalent Framework B provisions 53.6045 Updating final safety analysis reports.
See below.
53.6045(a)
Updating final safety analysis reports.
Part 53 Framework A (copies 53.1545(a), with modifications, and 10 CFR 50.71(e)
Modifications made to cross-reference equivalent Framework B provisions 53.6045(b)
Updating final safety analysis reports.
Part 53 Framework A (copies 53.1545(b)), with modifications, and 10 CFR 50.71(e)
Modifications made to cross-reference equivalent Framework B provisions 53.6045(c)
Updating final safety analysis reports.
10 CFR 50.71(e)(3)(iii), with modifications Modifications made to cross-reference equivalent Framework B provisions and address when a COL applicant or holder would no longer be required to
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) provide annual updates to the FSAR for new information or reevaluated conditions 53.6045(d)
Updating final safety analysis reports.
Part 53 Framework A (copies 53.1545(d)) and 10 CFR 50.71(e)(6)
Not applicable 53.6045(e)
Reserved.
53.6045(f)
Updating final safety analysis reports.
10 CFR 50.71(f), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6050 Evaluating changes to facility as described in final safety analysis reports.
10 CFR 50.59(c) and 10 CFR 50.59(d), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6052 Maintenance of risk evaluations.
See below.
53.6052(a)
Maintenance of risk evaluations.
10 CFR 50.71(h)(1), with modifications Modifications made to include the Alternate Evaluation for Risk Insights (AERI) approach 53.6052(b)
Maintenance of risk evaluations.
10 CFR 50.71(h)(2), with modifications Modifications made to include PRA maintenance and/or upgrade provisions for AERI and PRA 53.6052(c)
Maintenance of risk evaluations.
10 CFR 50.71(h)(3), with modifications Modifications made to reference equivalent Framework B provisions 53.6052(d)
Maintenance of risk evaluations.
New requirement based on 10 CFR 50.71(h)(3),
with modifications.
Modifications made to address the confirmation of the AERI during license renewal 53.6054 Control of aircraft impact assessments.
10 CFR 50.150(c), with modifications Modifications made to cross-reference equivalent Part 50 provisions in Framework B 53.6055 Control of licensing basis information in program descriptions.
Part 53 Framework A (copies 53.1555), with modifications Modifications made to reference equivalent Framework B provisions 53.6060 Updating program documents included in licensing basis information.
Part 53 Framework A (copies 53.1560), with modifications Modifications made to reference equivalent Framework B provisions 53.6065 Evaluating changes to programs included in licensing basis information.
Part 53 Framework A (copies 53.1565), with modifications Modifications made to reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.6070 Transfer of licenses or permits.
Part 53 Framework A (copies 53.1570), with modifications, and 10 CFR 50.80 Modifications made to reference equivalent Framework B provisions 53.6075 Termination of license.
Part 53 Framework A (copies 53.1575), with modifications, and 10 CFR 50.82 Modifications made to reference equivalent Framework B provisions 53.6080 Information requests.
Part 53 Framework A (copies 53.1580), with modifications, and 10 CFR 50.54(f)
Modifications made to reference equivalent Framework B provisions.
53.6085 Revocation, suspension, modification of licenses, permits, and approvals for cause.
Part 53 Framework A (copies 53.1585), with modifications, and 10 CFR 50.100 Modifications made to reference equivalent Framework B provisions.
53.6090 Backfitting.
10 CFR 50.109, with modifications Modifications made to reference equivalent Framework B provisions 53.6095 Renewal.
Part 53 Framework A (copies 53.1595)
Not applicable Subpart T - Reporting and Other Administrative Requirements 53.6300 General information.
Part 53 Framework A (copies 53.1600), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6310 Unfettered access for inspections.
Part 53 Framework A (copies 53.1610) and 10 CFR 50.70 Not applicable.
53.6320 Maintenance of records, making of reports.
See below 53.6320(a)
Maintenance of records, making of reports.
Part 53 Framework A (copies 53.1620(a)) and 10 CFR 50.71(a)
Not applicable 53.6320(b)
Reserved 53.6320(c)
Maintenance of records, making of reports.
Part 53 Framework A (copies 53.1620(c)), with modifications, and 10 CFR 50.71(c)
Modifications made to distinguish records and reports generated under Framework B 53.6320(d)
Maintenance of records, making of reports.
Part 53 Framework A (copies 53.1620(d)), with modifications, and 10 CFR 50.71(d)
Modifications made to distinguish records and reports generated under Framework B 53.6320(e)
Maintenance of records, making of reports.
Policy initiative associated with reporting requirement for fee purposes New requirement ensures licensee promptly notifies NRC of completion of power ascension testing so the NRC can assess part 171 fees
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.6330 Immediate notification requirements for operating commercial nuclear plants.
10 CFR 50.72, with modifications Modifications made to cross-reference equivalent Framework B provisions; reporting requirements aligned to those in 10 CFR 50.72 due to the similarities in SSC classification between Part 50 and Framework B 53.6340 Licensee event report system.
10 CFR 50.73, with modifications Modifications made to cross-reference equivalent Framework B provisions; reporting requirements aligned to those in 10 CFR 50.73 due to the similarities in SSC classification between Part 50 and Framework B 53.6345 Periodic reports.
Part 53 Framework A (copies 53.1645), with modifications, and 10 CFR 50.36a(a)(2)
Modifications made to cross-reference equivalent Framework B provisions 53.6350 Facility information and verification.
Part 53 Framework A (copies 53.1650) and 10 CFR 50.78 Not applicable 53.6360 Financial requirements.
Part 53 Framework A (copies 53.1660), with modifications Modifications made to cross-reference equivalent Framework B provisions 53.6370 Financial qualifications.
Part 53 Framework A (copies 53.1670), with modifications and 10 CFR 50.33 Modifications made to distinguish applicants under Framework B 53.6380 Annual financial reports.
Part 53 Framework A (copies 53.1680) and 10 CFR 50.71(b)
Not applicable 53.6390 Licensees change of status; financial qualifications.
See below 53.6390(a)
Licensees change of status; financial qualifications.
Part 53 Framework A (copies 53.1690(a)), with modifications, and 10 CFR 50.76 Modifications made to cross-reference equivalent Framework B provisions 53.6390(b)
Licensees change of status; financial qualifications.
Part 53 Framework A (copies 53.1690(b)) and 10 CFR 50.54(cc)
Not applicable 53.6400 Creditor regulations.
Part 53 Framework A (copies 53.1700), with modifications, and 10 CFR 50.81 Modifications made to cross-reference equivalent Framework B provisions 53.6410 Financial protection.
Part 53 Framework A (copies 53.1710), with modifications Modifications made to cross-reference equivalent Framework B provisions
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3) 53.6420 Insurance required to stabilize and decontaminate plant following an accident.
Part 53 Framework A (copies 53.1720), with modifications, and 10 CFR 50.54(w)
Modifications made to cross-reference equivalent Framework B subpart 53.6430 Financial protection requirements.
Part 53 Framework A (copies 53.1730)
Not applicable Subpart U - Quality Assurance 53.6600 General Provisions Part 53 Framework A (copies 53.1800), with modifications Modifications made to introductory text to align with introductory text in 10 CFR Part 50 Appendix B 53.6605 Organization 10 CFR Part 50 Appendix B Criterion I Not applicable 53.6610 Quality Assurance Program 10 CFR Part 50 Appendix B Criterion II Not applicable 53.6615 Design Control 10 CFR Part 50 Appendix B Criterion IIII Not applicable 53.6620 Procurement Document Control 10 CFR Part 50 Appendix B Criterion IV Not applicable 53.6625 Instructions, Procedures and Drawings 10 CFR Part 50 Appendix B Criterion V Not applicable 53.6630 Document Control 10 CFR Part 50 Appendix B Criterion VI Not applicable 53.6635 Control of Purchased Material, Equipment and Services 10 CFR Part 50 Appendix B Criterion VII, with modifications Modifications made to adopt commercial nuclear plant in lieu of nuclear power plant.
53.6640 Identification and Control of Materials, Parts and Components 10 CFR Part 50 Appendix B Criterion VIIII Not applicable 53.6645 Control of Special Processes 10 CFR Part 50 Appendix B Criterion IX Not applicable 53.6650 Inspection 10 CFR Part 50 Appendix B Criterion X Not applicable 53.6655 Test Control 10 CFR Part 50 Appendix B Criterion XI Not applicable 53.6660 Control of Measuring and Test Equipment 10 CFR Part 50 Appendix B Criterion XII Not applicable 53.6665 Handling, Storage and Shipping 10 CFR Part 50 Appendix B Criterion XIII Not applicable 53.6670 Inspection, Test and Operating Status 10 CFR Part 50 Appendix B Criterion XIV Not applicable 53.6675 Nonconforming Materials, Parts or Components 10 CFR Part 50 Appendix B Criterion XV Not applicable 53.6680 Corrective Action 10 CFR Part 50 Appendix B Criterion XVI Not applicable 53.6685 Quality Assurance Records 10 CFR Part 50 Appendix B Criterion XVII Not applicable 53.6690 Audits 10 CFR Part 50 Appendix B Criterion XVIII Not applicable
- Summary of Framework B Requirements and Source Section(s)
Section Title/Topic Source of Draft Requirement(1)(2)
Variance(s) from Source (if applicable)(3)
Notes:
(1) Several provisions in Part 53 Framework B are based on the preliminary proposed rule text for Part 53 Framework A. However, several of the provisions in Framework A are based on existing requirements in other parts of 10 CFR. Where appropriate, this column includes additional references to the sources of requirements from Framework A to assist in understanding where a given provision was derived, even if the Framework B draft preliminary proposed rule text was sourced from Framework A.
(2) Several provisions in Framework B were derived from 10 CFR Part 50 and 10 CFR Part 52. In some cases, the provisions from these parts include additional references to other requirements (e.g., 10 CFR 52.79(a)(8) references 10 CFR 50.44). To the extent practicable, this table denotes from where a particular provision for Framework B was sourced in addition to the base requirement associated with the source. In these cases, the table denotes that the Framework B references the base requirement by extension.
(3) For variances that state Modifications made to cross-reference equivalent Framework B provisions, this generally refers to a situation where the source requirement was adopted in its entirety, but conforming changes were required to address the organizational scheme in Framework B.
- Summary of Part 53 Framework B References to § 53.4730 General Technical Requirements 31 Part 53 Framework B Paragraph No.
Description of Part 53 Framework B Requirement Application Type (Technical Requirements Section in Part 53 Framework B)
(§ 53.4756)
(§ 53.4809)
(§ 53.4839)
(§ 53.4879)
(§ 53.4909)
(§ 53.4969)
(§ 53.5016) 53.4730(a)(1)
Site safety analysis.
See below.
53.4730(a)(1)(i)
Site safety analysis.
X X
X5 X
53.4730(a)(1)(ii)
Site safety analysis.
X X
X 53.4730(a)(1)(iii)
Site safety analysis.
X X
X 53.4730(a)(1)(iv)
Site safety analysis.
X X
X 53.4730(a)(1)(v)
Site safety analysis.
X X
X 53.4730(a)(1)(vi)
Site safety analysis.
X X
X X
X X
53.4730(a)(2)
Facility description.
X X
X X6 X
X X
53.4730(a)(3)
Kinds and quantities of radioactive materials.
X X
X X
X 53.4730(a)(4)
Design bases and principal design criteria X
X X
X X
X 53.4730(a)(5)
Initiating event and accident analysis See below.
53.4730(a)(5)(i)
Initiating event and accident analysis - Requirement for analysis and evaluation X
X X
X X
X 53.4730(a)(5)(ii)
Initiating event and accident analysis - DBA X
X X
X X
X 53.4730(a)(5)(iii)
Initiating event and accident analysis - AOO X
X X
X X
X 53.4730(a)(5)(iv)
Initiating event and accident analysis - BDBEs X
X X
X X
X 53.4730(a)(5)(v)
Initiating event and accident analysis - severe accidents X
X X
X X
X 53.4730(a)(5)(vi)
Initiating event and accident analysis - chemical hazards.
X X
X X
X X
53.4730(a)(6)
Fire protection.
X X
53.4730(a)(7)
Combustible gas control.
X X
X X
X X
53.4730(a)(8)
Environmental qualification of electric equipment important to safety.
See below.
53.4730(a)(8)(i)
Environmental qualification of electric equipment important to safety.
X X
53.4730(a)(8)(ii)
Environmental qualification of electric equipment important to safety.
X X
X 53.4730(a)(9)
Role of personnel.
X X
53.4730(a)(10)
Maintenance rule.
X X
5 See § 53.4969(a)(1); the full site evaluation should include a description of changes from the CP.
6 See § 53.4879(b)
- Summary of Part 53 Framework B References to § 53.4730 General Technical Requirements 32 Part 53 Framework B Paragraph No.
Description of Part 53 Framework B Requirement Application Type (Technical Requirements Section in Part 53 Framework B)
(§ 53.4756)
(§ 53.4809)
(§ 53.4839)
(§ 53.4879)
(§ 53.4909)
(§ 53.4969)
(§ 53.5016) 53.4730(a)(11)
Effluent control X
X X
X X
53.4730(a)(12)
Post-accident radiation monitoring and protection.
See below.
53.4730(a)(12)(i)
Post-accident radiation monitoring and protection X
X X
X X
X 53.4730(a)(12)(ii)
Post-accident radiation monitoring and protection X
X X
X X
X 53.4730(a)(12)(iii)
Post-accident radiation monitoring and protection X
X X
X X
X 53.4730(a)(13)
Reserved.
53.4730(a)(14)
Earthquake engineering criteria.
X X
X X
X X
53.4730(a)(15)
X X
X 53.4730(a)(16)
State and local government cooperation in emergency planning.
X X
53.4730(a)(17)
Safety feature testing, analyses, operating experience, and prototypes.
X X
X X
X 53.4730(a)(18)
Quality assurance program.
See below.
53.4730(a)(18)(i)
Quality assurance program X
X X
X X
X X
53.4730(a)(18)(ii)
Quality assurance program X
X X
X X
X X
53.4730(a)(18)(iii)
Quality assurance program X
X X
X X
X X
53.4730(a)(19)
Organizational structure.
X X
53.4730(a)(20)
Managerial and administrative controls.
See below.
53.4730(a)(20)(i)
Managerial and administrative controls X
X 53.4730(a)(20)(ii)
Managerial and administrative controls X
X 53.4730(a)(21)
Preoperational testing and initial startup.
X X
53.4730(a)(22)
Normal operations and maintenance.
X X
53.4730(a)(23)
Technical specifications.
See below.
53.4730(a)(23)(i)
Technical specifications.
X X
53.4730(a)(23)(ii)
Technical specifications.
X X
53.4730(a)(24)
Fitness-for-duty programs.
X X
53.4730(a)(25)
Multi-unit sites X
X X
53.4730(a)(26)
Technical qualifications.
X X
X X
X X
53.4730(a)(27)
Training program.
X X
53.4730(a)(28)
Physical security program.
X X
53.4730(a)(29)
X X
53.4730(a)(30)
Operating experience.
X X
X X
- Summary of Part 53 Framework B References to § 53.4730 General Technical Requirements 33 Part 53 Framework B Paragraph No.
Description of Part 53 Framework B Requirement Application Type (Technical Requirements Section in Part 53 Framework B)
(§ 53.4756)
(§ 53.4809)
(§ 53.4839)
(§ 53.4879)
(§ 53.4909)
(§ 53.4969)
(§ 53.5016) 53.4730(a)(31)
Radiation protection program X
X 53.4730(a)(32)
Criticality accident requirements.
X X
X X
X 53.4730(a)(33)
Minimization of contamination.
X X
X X
X 53.4730(a)(34)
Risk evaluations.
See below.
53.4730(a)(34)(i)
Risk evaluations - PRA X
X X
X X
X 53.4730(a)(34)(ii)
Risk evaluations - AERI X
X X
X X
X 53.4730(a)(35)
Aircraft impact assessment.
X X
X X
X X
53.4730(a)(36)
Functional containment.
See below.
53.4730(a)(36)(i)
Functional containment - NLWR X
X X
X X
53.4730(a)(36)(ii)
Functional containment - LWR X
X X
X X
53.4730(a)(37)
Water-cooled reactor requirements.
See below.
53.4730(a)(37)(i)
Emergency core cooling systems.
X X
X X
X X
53.4730(a)(37)(ii)
Codes and standards.
X X
X 53.4730(a)(37)(iii)
Pressurized thermal shock and fracture toughness requirements.
X X
X X
X 53.4730(a)(37)(iv)
Anticipated transients without scram.
X X
X X
X 53.4730(a)(37)(v)
Station blackout.
X X
X X
X 53.4730(a)(37)(vi)
Reactor vessel material surveillance.
X X
53.4730(a)(37)(vii)
Containment leakage testing.
X X
53.4730(a)(37)(viii)
Standard review plan evaluation.7 X
X X
53.4730(a)(37)(ix)
Resolution of generic issues.
X X
X X
X 53.4730(a)(37)(x)
Requirements from LWR operating experience.
See below.
53.4730(a)(37)(x)(A)
Requirements from LWR operating experience.
X X
X X
X X
53.4730(a)(37)(x)(B)
Requirements from LWR operating experience.
X X
X X
X X
53.4730(a)(37)(x)(C)
Requirements from LWR operating experience.
X X
X X
X X
7 Evaluation of the applicability of this requirement is ongoing.