Dominion Energy Nuclear Connecticut, Inc.
Millstone Power Station 314 Rope Ferry Road, Waterford, CT 06385 DominionEnergy.com U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 DOMINION ENERGY NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 3 CORE OPERATING LIMITS REPORT, CYCLE 22 P
Dominion ij I Energy Serial No.
NSSL/CRD Docket No.
License No.22-119 R1 50-423 NPF-49 MAY 1 2 2022 In accordance with the Millstone Power Station Unit 3 (MPS3) Technical Specifications (TSs), Section 6.9.1.6.d, Dominion Energy Nuclear Connecticut, Inc., hereby submits, as, the Cycle 22 Core Operating Limits Report (COLR).
The changes to the MPS3 COLR for Cycle 22 are summarized below:
(1) LBDCR 20-MP3-004 implemented on April 21, 2022.
(a) Administrative changes to increment the cycle number from 21 to 22.
(b) Analytical Methods/Reference revised to replace WCAP-16009-P-A with WCAP-16996-P-A as approved by MPS3 TS Amendment 279:
(c) Changes to COLR limits using the NRG-approved methodologies. The changed parameters include:
Penalty Factors for Flux Map Analysis Normal Operating Space Reductions fpr Non-Equilibrium Fo(Z) Exceeding its Limits (2) LBDCR 21-MP3-011 implemented on May 3, 2022.
(a) The terminology of control and shutdown "rods" was changed to "banks" to align with terminology used in the NRG approved MPS3 TS Amendment 282.
The COLR has been incorporated into the MPS3 Technical Requirements Manual.
If you have any questions or require additional information, please contact Dean E. Rowe at (860) 444-5292.
Sincerely,
~~-
L. J. Armstrong Director, Nuclear Station Safety and Licensing - Millstone
Enclosures:
(1)
Commitments made in this letter: None
cc:
Regional Administrator U.S. Nuclear Regulatory Commission Region I 475 Allendale Road, Suite 102 King of Prussia, PA 19406-1415 R. V. Guzman Serial No.22-119 Docket No. 50-423 Core Operating Limits Report, Cycle 22 Page 2 of 2 Senior Project Manager - Millstone Power Station U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08 C2 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Millstone Power Station
ENCLOSURE 1 Serial No.22-119 Docket No. 50-423 CORE OPERATING LIMITS REPORT, CYCLE 22 DOMINION ENERGY NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 3
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT CYCLE 22 MILLSTONE - UNIT 3 TRM 8.1-1 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Table of Contents Section INTRODUCTION...................................................................................................................... 8.1-4 2.0 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS........................................ 8.1-4 2.1 Safety Limits........................................................................................................................ 8.1-4 2.2 Limiting Safety System Settings.......................................................................................... 8.1-5 3.0/4.0 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS
........................................................................................................................................ 8.1-7 SHUTDOWN MARGIN - MODES 1 and 2................................................................. 8.1-7 SHUTDOWN MARGIN - MODES 3, 4 and 5 Loops Filled........................................ 8.1-7 SHUTDOWN MARGIN - COLD SHUTDOWN - Loops Not Filled............................. 8.1-7 Moderator Temperature Coefficient........................................................................... 8.1-8 Shutdown Bank Insertion Limits................................................................................ 8.1-9 Control Bank Insertion Limits..................................................................................... 8.1-9 3/4.2.1 AXIAL FLUX DIFFERENCE................................................................................... 8.1-9 3/4.2.2 Heat Flux Hot Channel Factor-Fa(Z).................................................................. 8.1-10 3/4.2.3 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor......................... 8.1-12 3/4.2.5 DNB Parameters.................................................................................................. 8.1-12 3/4.3.5 Shutdown Margin Monitor.................................................................................... 8.1-13 3/4.9 Refueling Operations............................................................................................... 8.1-14 ANAYLTICAL METHODS/ REFERENCES............................................................................ 8.1-25 MILLSTONE - UNIT 3 TRM 8.1-2 LBDCR 21-MP3-011
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 List of Figures Figure Title Page Figure 1 Reactor Core Safety Limits.................................................................................... 8.1-15 Figure 2 Required SHUTDOWN MARGIN for MODE 3....................................................... 8.1-16 Figure 3 Required SHUTDOWN MARGIN for MODE 4....................................................... 8.1-17 Figure 4 Required SHUTDOWN MARGIN for MODE 5 with RCS Loops Filled................... 8.1-18 Figure 5 Required SHUTDOWN MARGIN for COLD SHUTDOWN with RCS Loops Not Filled
.................................................................................................................................. 8.1-19 Figure 6 Control Rod Bank Insertion Limits versus RATED THERMAL POWER................. 8.1-20 Figure 7 AXIAL FLUX DIFFERENCE Limits as a Function of RATED THERMAL POWER. 8.1-21 Figure 8 K(Z) - Normalized Fo(Z) as a Function of Core Height.......................................... 8.1-22 Table Table 1 Table 2 List of Tables Title Penalty Factors for Flux Map Analysis................................................................... 8.1-23 Required Normal Operating Space Reductions for Fo(Z) Exceeding Its Non-Equilibrium Limits..................................................................................................................... 8.1-24 MILLSTONE - UNIT 3 TRM 8.1-3 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 INTRODUCTION Millstone Unit 3 Cycle 22 CORE OPERATING LIMITS REPORT This CORE OPERATING LIMITS REPORT (COLR) for Millstone Unit 3 Cycle 22 has been prepared in accordance with the requirements of Technical Specification 6.9.1.6.a.
The Technical Specifications affected by this report are listed below.
2.1.1 Reactor Core Safety Limits 2.2.1 Limiting Safety System Settings 3/4.1.1.1.1 SHUTDOWN MARGIN - MODES 1 and 2 3/4.1.1.1.2 SHUTDOWN MARGIN - MODES 3, 4 and 5 Loops Filled 3/4.1.1.2 SHUTDOWN MARGIN - COLD SHUTDOWN - Loops Not Filled 3/4.1.1.3 Moderator Temperature Coefficient 3/4.1.3.5 Shutdown Bank Insertion Limits 3/4.1.3.6 Control Bank Insertion Limits 3/4.2.1.1 AXIAL FLUX DIFFERENCE 3/4.2.2.1 Heat Flux Hot Channel Factor 3/4.2.3.1 RCS Total Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor 3/4.2.5 DNB Parameters 3/4.3.5 Shutdown Margin Monitor 3/4.9.1.1 Refueling Operations Boron Concentration The cycle-specific parameter limits for the specifications listed above are presented in the following subsections. These limits have been developed using the NRG-approved methodologies specified in Technical Specification 6.9.1.6.b.
Cycle-specific values are presented in bold. Text in italics is provided for information only.
2.0 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS 2.1 Safety Limits Reactor Core 2.1.1 The combination of THERMAL POWER, Reactor Coolant System highest loop average temperature, and pressurizer pressure shall not exceed the limits shown in Figure 1.
MILLSTONE - UNIT 3 TRM 8.1-4 LBDCR 21-MP3-011
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 2.2 Limiting Safety System Settings Reactor Trip System Instrumentation Setpoints 2.2.1 The Reactor Trip System Instrumentation and Interlock Setpoints shall be set consistent with the Nominal Trip Setpoint values shown in Table 2.2-1.
Table 2.2-1 Note 1: Overtemperature ~ T
[ LffJ(l+ 115) <K1 -K2 (1+ 145) (T-T')+K (P-P')
~Toj(l +12s) -
(1 +15 s) 3 fi(M)
Where:
~Tis measured Reactor Coolant System~ T, °F;
~To is loop specific indicated ~Tat RATED THERMAL POWER, °F; (1+11s)
(1+12s) is the function generated by the lead-lag compensator on measured ~ T; 1 1 and 1 2 are the time constants utilized in the lead-lag compensator for
~ T, 1 1 ?. 8 sec, 1 2.:5. 3 sec; (1+14s)
(1 +-r5s) is the function generated by the lead-lag compensator for 1 4 and -r5 are the time constants utilized in the lead-lag compensator for T avg, 14 ?. 20 sec, -r5.:::. 4 sec; T is measured Reactor Coolant System average temperature, °F; T' is loop specific indicated Tavg at RATED THERMAL POWER,
.:5. 587.1 °F; K3 ~ 0.00113 / psi; P is measured pressurizer pressure, psia; MILLSTONE - UNIT 3 TRM 8.1-5 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 P' is nominal pressurizer pressure, ;;:: 2250 psia; s is the Laplace transform operator, sec-1; and f1 (~I) is a function of the indicated difference between top and bottom detectors of the power range neutron ion chambers; with nominal gains to be selected based on measured instrument response during plant startup tests calibrations such that:
- 1. For qt - % between -18% and +10%, f1(~1) 2 0, where qt and qb are percent RATED THERMAL POWER in the upper and lower halves of the core, respectively, and qt+% is the total THERMAL POWER in percent RATED THERMAL POWER;
- 2. For each percent that the magnitude of qt - % exceeds -18%, the ~ T Trip Setpoint shall be automatically reduced by 2 3.75% of its value at RATED THERMAL POWER;
- 3. For each percent that the magnitude of qt - % exceeds +10%, the~ T Trip Setpoint shall be automatically reduced by 2 2.14% of its value at RATED THERMAL POWER.
Table 2.2-1 Note 3: Overpower AT Where:
~Tis measured Reactor Coolant System~ T, °F;
~To is loop specific indicated.LlT at RATED THERMAL POWER, °F; (l+-r1s)
(l+-r2s) is the function generated by the lead-lag compensator on measured ~ T;
-r1 and -r2 are the time constants utilized in the lead-lag compensator for
~T, -r1.:::. 8 sec, -r2.:s 3 sec; Tis measured average Reactor Coolant System temperature, °F; MILLSTONE - UNIT 3 TRM 8.1-6 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 T" is loop specific indicated T avg at RATED THERMAL POWER, s 587.1 °F; K6 2 0.0015 / °F when T > T" and K6 s 0 I °F when Ts T";
s is the Laplace transform operator, sec-1; 3.0/4.0 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.1 Reactivity Control Systems 3/4.1.1.1 Boration Control SHUTDOWN MARGIN - MODES 1 and 2 3.1.1.1.1 The SHUTDOWN MARGIN shall be greater than or equal to 1.3% t1k/k.
The COLR limit of Specification 4.1.1.1.1 is defined in Specification 3.1.1.1.1.
SHUTDOWN MARGIN - MODES 3, 4 and 5 Loops Filled 3.1.1.1.2 The SHUTDOWN MARGIN shall be greater than or equal to the limits shown in
- Figure 2 for MODE 3,
- Figure 3 for MODE 4, and
- Figure 4 for MODE 5 with RCS Loops Filled.
The COLR limit of Specification 4.1.1.1.2.1 is defined in Specification 3.1. 1. 1.2.
SHUTDOWN MARGIN - COLD SHUTDOWN - Loops Not Filled 3.1.1.2 The SHUTDOWN MARGIN shall be greater than or equal to
- a. the limits shown in Figure 5 for MODE 5 with RCS loops not filled or
- b. the limits shown in Figure 4 for MODE 5 with RCS loops filled with the chemical and volume control system (CVCS) aligned to preclude reactor coolant system boron concentration reduction.
The COLR limit of Specification 4.1.1.2.1 is defined in Specification 3.1.1.2.
MILLSTONE - UNIT 3 TRM 8.1-7 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Moderator Temperature Coefficient 3.1.1.3 The moderator temperature coefficient (MTC) shall be within the limits specified below:
Where:
The maximum upper limit shall be less positive than
+0.5 x 104 L'.lk/k/°F for all the rods withdrawn, beginning of cycle life (BOL), condition for power levels up to 70% RATED THERMAL POWER with a linear ramp to O L'.lk/k/ °Fat 100% RATED THERMAL POWER.
The MTC EOL limit is:
The ARO/EOL/RTP MTC shall be less negative than
- 5.35 x 10-4 ak/k/°F (-53.5 pcm/°F).
The MTC 300 ppm surveillance limit is:
The 300 ppm/ARO/RTP MTC shall be less negative than or equal to - 4.4 x 1 o-4 ak/k/°F (-44 pcm/°F).
- BOL stands for Beginning of Cycle of Life
- ARO stands for All Rods Out
- EOL stands for End of Cycle Life
- RTP stands for RATED THERMAL POWER The COLR limits of Specification 4.1.1.3 are defined by Specification 3.1.1.3 limits given above.
MILLSTONE - UNIT 3 TRM 8.1-8 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 3/4.1.3 3/4.2 3/4.2.1 Moveable Control Assemblies Shutdown Bank Insertion Limits 3.1.3.5 Each shutdown bank shall be at least 220 steps withdrawn The COLR limit of Specification 4.1.3.5 is defined in Specification 3.1.3.5.
Control Bank Insertion Limits 3.1.3.6 The control banks shall be limited in physical insertion
- as shown in Figure 6 for control banks B, C, and D, and
- control bank A shall be at least 220 steps withdrawn The insertion limits of Specification 4.1.3.6 are defined in Specification 3.1.3.6.
Power Distribution Limits AXIAL FLUX DIFFERENCE 3.2.1.1 The indicated AXIAL FLUX DIFFERENCE (AFD) shall be maintained within the limits shown in Figure 7.
The AFD limits of Specifications 4.2.1.1.1 and 4.2.1.1.2 are defined in Specification 3.2.1.1.
MILLSTONE - UNIT 3 TRM 8.1-9 LBDCR 21-MP3-011
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 3/4.2.2 Heat Flux Hot Channel Factor - F0 (Z) 3.2.2.1 F0(Z), as approximated by F0M(z), shall be within the limits specified below:
FRTP F0M(Z) _:s
~ x K(Z) ; for P > 0.5 FRTP F0M(Z) _:s -
0-x K(Z) ; for P ~ 0.5
0.5 Where
THERMAL POWER p = ----------
RATED THERMAL POWER FaRTP = 2.60 K(Z) = the normalized F 0 (Z) as a function of core height as shown in Figure 8.
MILLSTONE - UNIT 3 TRM 8.1-10 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Where:
The Heat Flux Hot Channel Factor non-equilibrium limit is:
THERMAL POWER p = ----------
RATED THERMAL POWER FaRTP = 2.60 K(Z) = the normalized F 0 (Z) as a function of core height as shown in Figure 8 Fq(z), Maximum Condition I N(z) =
FQ(z), Equilibrium Condition I N(z) values are calculated for each flux map using analytically derived F0 (Z) values, consistent with the methodology described in VEP-NE-1.
The factors in Table 1 shall be used for surveillance requirement 4.2.2.1.2.
The values provided in Table 2 shall be used to reduce the normal operating space for F0 M(Z) exceeding its non-equilibrium limits.
The Heat Flux Hot Channel Factor limits of Specifications 4.2.2.1.2 are defined in Specification 3.2.2.1 and the Heat Flux Hot Channel Factor non-equlibrium limit given above.
MILLSTONE - UNIT 3 TRM 8.1-11 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 3/4.2.3 3/4.2.5 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor 3.2.3.1 The indicated Reactor Coolant System (RCS) total flow rate and FN ll.H shall be maintained as follows:
- a. RCS Total Flow Rate ;;:: 363,200 gpm (TS Limit) and greater than or equal to 379,200 gpm (COLR Limit), and
- b. F:H::; F~P [1.0 + PF t,.H (1.0 - P)]
Where: p =
THERMAL POWER RATED THERMAL POWER FRTP t.H = FN ll.H limit at RATED THERMAL POWER = 1.586 PF t.H = the power factor multiplier for FN ll.H = 0.3 for P < 1.0 The COLR limits of Specification 4.2.3.1.3 are defined in Specification 3.2.3.1.a.
DNB Parameters 3.2.5 The following DNB-related parameters shall be maintained within the limits specified below
- a. Reactor Coolant System T avg shall be maintained :::; 593.5°F
- b. Pressurizer Pressure shall be maintained ~ 2204 psia 1 The COLR limits of Specification 4.2.5 are defined in Specification 3.2.5.
1Limit not applicable during either a THERMAL POWER ramp in excess of 5% of RA TED THERMAL POWER per minute or a THERMAL POWER step in excess of 10% of RATED THERMAL POWER.
MILLSTONE - UNIT 3 TRM 8.1-12 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 3/4.3 3/4.3.5 Instrumentation Shutdown Margin Monitor 3.3.5 Two channels of Shutdown Margin Monitors shall be OPERABLE
- a. With a minimum count rate and alarm ratio setting as shown below, or
- b. If the minimum count rate in Specification 3.3.5.a cannot be met, then the Shutdown Margin Monitors may be made OPERABLE with a lower minimum count rate and alarm ratio setting as shown below by borating the Reactor Coolant System above the requirements of Specification 3.1.1.1.2 or 3.1.1.2. The additional boration shall be:
- 1. A minimum of 150 ppm above the SHUTDOWN MARGIN requirements specified in Figure 2 for MODE 3, or
- 2. A minimum of 350 ppm above the SHUTDOWN MARGIN requirements specified in the
- Figure 3 for MODE 4
- Figure 4 for MODE 5 with RCS loops filled, and
- Figure 5 for MODE 5 with RCS loops not filled.
Tech. Spec. LCO SMM Alarm Ratio Setting Min. Count Rate (counts/sec) 3.3.5.a 1.50 1.0 1.25 0.6 3.3.5.b.1 1.50 0.50 1.25 0.35 3.3.5.b.2 1.50 0.35 1.25 0.25 The combination of the SMM Alarm Ratio setting and minimum count rate accounts for the time lag between the indicated and actual count rates, as well as other uncertainties. The specified SMM Alarm Ratio setting ensures that the assumption that an alarm is generated at flux doubling in the Boron Dilution Event analysis remain valid. The count rate is displayed on the SMM.
The COLR limits of Specification 4.3.5 are defined in Specification 3.3.5.
MILLSTONE - UNIT 3 TRM 8.1-13 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 3/4.9 3/4.9.1 Refueling Operations Boron Concentration 3.9.1.1 The boron concentration of all filled portions of the Reactor Coolant System and the refueling canal shall be maintained sufficient to ensure that the more restrictive of the following reactivity conditions is met; either:
- a. A i<etf of 0.95 or less, or
- b. A boron concentration of greater than or equal to 2600 pprn2 Additionally, the eves valves of Specification 4.1.1.2.2 shall be closed and secured in position.
2This boron concentration bounds the condition ofkeff_s 0.95 (all rods in less the most reactive two rods) and subcriticality (keff_::: 1.0 with all rods out).
MILLSTONE - UNIT 3 TRM 8.1-14 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 1-Reactor Core Safety Limits 680.0 -,--------------------------~
660.0 640.0 ii" 0
(!)
~620.0 Cl) u 0:::
600.0 580.0 2425 PSIA 2250 PSIA 2000 PSIA ACCEPTABLE OPERATION UNACCEPTABLE OPERATION
' \\
\\
\\
\\
\\
\\
\\
\\
\\
"\\
560. 0 +---'--'-----'---+---'--'---'---+---'---'--'--l---'-'---'---+---'----'---'---+----..___-'---1 0
0.2 0.4 0.6 0.8 1
1.2 FRACTION OF RATED THERMAL POWER MILLSTONE - UNIT 3 TRM 8.1-15 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22
~
<l
';:!:?.
0 4.0 3.5 3.0
~ 2.5
(!)
0:::
<(
~ 2.0 z s 0
~ 1.5 I
Cl) 1.0 0.5 0.0 lo, 1.3001 0
MILLSTONE - UNIT 3 Figure 2-Required SHUTDOWN MARGIN for MODE 3 I 1550, 3.ooo I V
~ V
/
/'
I 550, 1.300 I 500 1000 1500 2000 RCS CRITICAL BORON CONCENTRATION (ppm)
TRM 8.1-16 I 2500, 3.ooo I 2500 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 3-Required SHUTDOWN MARGIN for MODE 4 6.0 5.5 1 1250, 5.300 I 5.0 4.5 4.0
- ',§ e 3.5 C -~
- E 3.0 C
~
5 2.5
.c "'
2.0 1.5
/
/
/
V
/
/
V
/
0,1.3001
/
7 1.0 I 150, 1.3001 0.5 0.0 0
500 1000 1500 RCS Critical Boron Concentration (ppm)
TRM 8.1-17 MILLSTONE - UNIT 3 I 2500, 5.300 2000 2500 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 4-Required SHUTDOWN MARGIN for MODE 5 with RCS Loops Filled 6.0 5.5 5.0 4.5 4.0
~
~ 3.5 C.§
~ 3.0 C
~
~ 2.5
..c
<I) 2.0 1.5 1.0 0.5 0.0
/
lo,1.3001 /
/ I 150, 1.3001 0
MILLSTONE - UNIT 3 I 1250, 5.440 I
/
/
/
/
/
/v 500 1000 1500 2000 RCS Critical Boron Concentration (ppm)
TRM 8.1-18 I 2500, 5.440 I 2500 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 5-Required SHUTDOWN MARGIN for COLD SHUTDOWN with RCS Loops Not Filled 7.0 6.5 6.0 5.5 5.0 4.5
- s2"
<l e 4.o C *~
~ 3.5 C
3:.g 3.0
.c V) 2.5 2.0 1.5 1.0 o.s 0.0 V
0,1.3001
/
/
1170, 1.3001 0
MILLSTONE - UNIT 3
/
/
500 11soo, 6.150 I I 2500, 6.150 I 11125,5.60~ -
V
/
/
/
/
1000 1500 2000 2500 RCS Critical Boron Concentration (ppm)
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 6-Control Rod Bank Insertion Limits versus RATED THERMAL POWER 240 123.7%, 220 I I 14.1%, 220 I 220 200 180 z
~ 160 er:
0 I I-140
(/)
0..
w I-120
(/)
z 0
I-100
(/)
0 0..
~
80 z
<(
en 0
0 60 er:
40
/
/
/
/
/ I Control Bank B
/
/
/
V V
1100.0%, 164 I H 0.0%, 166:
I I
~
V
- Control Bank C :
/
/
/
/
II"
/
/
/
//
~ Control Bank D ~
/
/
/
Vr V
I 0.0%, s1 I
/
/
20
/
/12s.0%,o I 0
/
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 RATED THERMAL POWER(%)
MILLSTONE - UNIT 3 TRM 8.1-20 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22
~
0 --
0::: w s 0
CL
.J
<(
2 0::: w I I-0 w
~
120.0 100.0 80.0 60.0 40.0 20.0 0.0
-60 Figure 7-AXIAL FLUX DIFFERENCE Limits as a Function of RATED THERMAL POWER l-12, 100 I lg, 1001 UNACCEPTABLE UNACCEPTABLE OPERATION OPERATION
\\
I
\\
ACCEPTABLE OPERATION l-3o, 50 I 127,50
-40
-20 0
20 40 FLUX DIFFERENCE(% DELTA I) 60 MILLSTONE - UNIT 3 TRM 8.1-21 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Figure 8-K(Z) - Normalized F0 (Z) as a Function of Core Height 1.2 1.1 1.0 0.9 N
SZ'
~0.8 0 t,
<t:: 0.7 LL (9
z
~ 0.6 ifi CL
@ 0.5 N
- J
<(
~ 0.4 Cl:'.
0 z 0.3 0.2 0.1 0.0 K(Z) 1.0 1.0 0.925 0
1 2
MILLSTONE - UNIT 3 Elevation 0.0 ft 6.0 ft 12.0 ft 3
4 5
6 7
8 CORE ELEVATION (FEET)
TRM 8.1-22 9
10 11 12 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Table 1 Penalty Factors for Flux Map Analysis Burnup (MWD/MTU)
Penalty(%)
0-999 2.0 1000-1999 2.5 2000-2999 4.5 3000-3999 3.0 4000-4999 2.0 5000-6999 2.0 7000-8999 2.0 9000-10999 2.0 11000-12999 2.0 13000-14999 2.0 15000-16999 2.0 17000-18999 2.0 19000-EOC 2.0 MILLSTONE - UNIT 3 TRM 8.1-23 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 Table 2 Required Normal Operating Space Reductions for F0 (Z) Exceeding Its Non-Equilibrium Limits Required Required Required Negative Required Positive Non-Equilibrium THERMAL Band AFD Band AFD Reduction F0 (Z) Margin POWER Limit Reduction (3/4AFD)
(3/4AFD)
Improvement(%)
(3/4RTP)
> 0% and$ 1%
$ 98.0%
2:, 1.5%
2:. 1.5%
> 1% and $2%
$97.0%
2:. 1.5%
2:. 2.0%
> 2% and $3%
$96.0%
2:,3.0%
2:. 3.5%
>3%
$50%
N/A N/A
- AFD Limits are provided in COLR Figure 7.
MILLSTONE - UNIT 3 TRM 8.1-24 LBDCR 22-MP3-004
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22 ANAYLTICAL METHODS/ REFERENCES The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRG, specifically those described in the following documents.
- 1.
VEP-FRD-42-A, Revision 2, Minor Revision 2, "Reload Nuclear Design Methodology," October 2017.
Methodology for Specifications:
- 2.1.1 Reactor Core Safety Limits
- 3.1.1.1.1 SHUTDOWN MARGIN-MODES 1 AND 2
- 3.1.1.1.2 SHUTDOWN MARGIN-MODES 3, 4, and 5 Loops Filled
- 3.1.1.2 SHUTDOWN MARGIN - COLD SHUTDOWN - Loops Not Filled
- 3.1.1.3 Moderator Temperature Coefficient
- 3.1.3.5 Shutdown Bank Insertion Limits
- 3.1.3.6 Control Bank Insertion Limits
- 3.2.2.1 Heat Flux Hot Channel Factor
- 3.2.3.1 Nuclear Enthalpy Rise Hot Channel Factor
- 3.3.5 Shutdown Margin Monitor
- 3.9.1.1 Refueling Operations Boron Concentration
- 2.
VEP-NE-1-A, Revision 0, Minor Revision 3, "Relaxed Power Distribution Control Methodology and Associated FQ Surveillance Technical Specifications," October 2017.
Methodology for Specifications:
- 3.2.1.1 AXIAL FLUX DIFFERENCE
- 3.2.2.1 Heat Flux Hot Channel Factor
- 3.
WCAP-16996-P-A, "Realistic LOCA Evaluation Methodology Applied to the Full Spectrum of Break Sizes (FULL SPECTRUM LOCA Methodology),"
November 2016 (Westinghouse Proprietary).
Methodology for Specification:
- 3.2.2.1 Heat Flux Hot Channel Factor
- 4.
WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code," August 1985 (Westinghouse Proprietary).
Methodology for Specification:
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22
- 5.
WCAP-10054-P-A, Addendum 2, Revision 1, "Addendum to the Westinghouse Small Break EGGS Evaluation Model Using the NOTRUMP Code: Safety Injection into the Broken Loop and COSI Condensation Model," July 1997 (Westinghouse Proprietary).
Methodology for Specification:
- 3.2.2.1 Heat Flux Hot Channel Factor
- 6.
WCAP-10079-P-A, "NOTRUMP -A Nodal Transient Small Break and General Network Code," August 1985 (Westinghouse Proprietary).
Methodology for Specification:
- 3.2.2.1 Heat Flux Hot Channel Factor
- 7.
WCAP-12610-P-A, "VANTAGE+ Fuel Assembly Report," April 1995 (Westinghouse Proprietary).
Methodology for Specification:
- 3.2.2.1 Heat Flux Hot Channel Factor
- 8.
WCAP-12610-P-A & CENPD-404-P-A, Addendum 1-A, "Optimized ZIRLO'," July 2006 (Westinghouse Proprietary).
Methodology for Specification:
- 3.2.2.1 Heat Flux Hot Channel Factor
- 9.
WCAP-11946, "Safety Evaluation Supporting a More Negative EOL Moderator Temperature Coefficient Technical Specification for the Millstone Nuclear Power Station Unit 3," September 1988 (Westinghouse Proprietary).
Methodology for Specification:
- 3.1.1.3 Moderator Temperature Coefficient
- 10.
WCAP-87 45-P-A, "Design Bases for the Thermal Overpower 1::,. T and Thermal Overtemperature 1::,. T Trip Functions," September 1986 (Westinghouse Proprietary).
Methodology for Specification:
- 2.2.1 Overtemperature 1::,. T and Overpower 1::,. T Setpoints
- 11.
VEP-NE-2-A, Revision 0, "Statistical DNBR Evaluation Methodology," June 1987.
Methodology for Specification:
- 3.2.3.1 RCS Flow Rate, Nuclear Enthalpy Rise Hot Channel Factor
TECHNICAL REQUIREMENTS MANUAL APPENDIX 8.1 CORE OPERATING LIMITS REPORT, CYCLE 22
- 12.
DOM-NAF-2-P-A, Revision 0, Minor Revision 3, "Reactor Core Thermal-Hydraulics Using the VIPRE-D Computer Code," including Appendix C, "Qualification of the Westinghouse WRB-2M CHF Correlation in the Dominion VIPRE-D Computer Code," and Appendix D, "Qualification of the ABB-NV and WLOP CHF Correlations in the Dominion VIPRE-D Computer Code," September 2014.
Methodology for Specification:
- 3.2.3.1