ML22090A230
| ML22090A230 | |
| Person / Time | |
|---|---|
| Site: | 03038522 |
| Issue date: | 03/31/2022 |
| From: | Ricardo Torres NRC/RGN-IV/DRSS |
| To: | Document Control Desk |
| References | |
| License-630537-164870 | |
| Download: ML22090A230 (1) | |
See also: IR 05000294/2039001
Text
U.S. NUCLEAR REGULATORY COMMISSION
MATERIALS LICENSE
PAGE
OF
1
5
Amendment No. 3
PAGES
Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter I,
Parts 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 70 and 71, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued
authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s)
and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This
license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and
orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.
Licensee
Chitina, AK 99566
2. P.O. Box 118
1. Wrangell Mountain Technical Services
4. Expiration Date: March 31, 2024
Docket No.:
5.
030-38522
License No.: 50-29439-01 is
renewed in its entirety to read as
follows:
Reference No.:
3.
In accordance with application
dated March 30, 2022; and letter
dated March 30, 2022,
6.
7.
8.
Byproduct, source,
and/or special nuclear
material
Chemical and/or physical form
Maximum amount that licensee
may possess at any one time
under this license
9.
Authorized use
A.
A.
A.
A.
Possession and storage only with
intent to dispose of a Humboldt
Scientific, Inc., Model 5001 portable
gauging device.
Sealed Sources (AEA
Technology/QSA, Inc., Model
CDC.805; Isotope Products
Laboratories, Model HEG-137)
11 millicuries per source
and 11 millicuries total
B.
B.
B.
B.
Possession and storage only with
intent to dispose of a Humboldt
Scientific, Inc., Model 5001 portable
gauging device.
Sealed Neutron Source (AEA
Technology/QSA, Inc., Model
AMNV.997; Isotope Products
Laboratories, Model AM1.NO2)
44 millicuries per source
and 44 millicuries total
Americium-241/
C.
C.
C.
C.
Possession and storage only with
intent to dispose of a Seaman Nuclear
Corporation Model C-200 Series
portable gauging device.
Sealed Neutron Source (AEA
Technology/QSA, Inc., Model
RAN.C1; Gammatron, Inc.,
Model GT-GHP; Radium
Chemical Company, Model
Drawing 21.94)
5.5 millicuries per source
and 5.5 millicuries total
Radium-226/ Beryllium
License No.:
Docket or Reference No.:
U.S. NUCLEAR REGULATORY COMMISSION
MATERIALS LICENSE
SUPPLEMENTARY SHEET
PAGES
OF
PAGE
5
2
50-29439-01
030-38522
Amendment No. 3
CONDITIONS
10. Licensed material may be used or stored at the licensee's facilities located at:
A. Mile 32.1 Edgerton Highway, Chitina, Alaska, 99566
B. 1800 Richardson Highway, Valdez, Alaska, 99686
C. Temporary job sites anywhere in the United States where the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulating
the use of licensed material, including areas of exclusive Federal jurisdiction within Agreement States.
If the jurisdiction status of a Federal facility within an Agreement State is unknown, the licensee should contact the Federal agency
controlling the job site in question to determine whether the proposed job site is an area of exclusive Federal jurisdiction. Authorization
for use of radioactive materials at job sites in Agreement States not under exclusive Federal jurisdiction shall be obtained from the
appropriate state regulatory agency.
11.
Licensed material shall only be used by, or under the supervision and in the physical presence of, individuals who have received the
training described in the application dated February 25, 2012. The licensee shall maintain records of individuals designated as users for 3
years following the last use of licensed material by the individual.
12. The Radiation Safety Officer (RSO) for this license is Allen D. Minish, P.E.
13. A.
Sealed sources shall be tested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of
registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State. In the absence of a
registration certificate, sealed sources shall be tested for leakage and/or contamination at intervals not to exceed 6 months, or at such
other intervals as specified.
B.
In the absence of a certificate from a transferor indicating that a leak test has been made within the intervals specified in the certificate
of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State, prior to the
transfer, a sealed source received from another person shall not be put into use until tested and the test results received.
License No.:
Docket or Reference No.:
U.S. NUCLEAR REGULATORY COMMISSION
MATERIALS LICENSE
SUPPLEMENTARY SHEET
PAGES
OF
PAGE
5
3
50-29439-01
030-38522
Amendment No. 3
C. Sealed sources need not be tested if they are in storage and are not being used. However, when they are removed from storage for
use or transferred to another person, and have not been tested within the required leak test interval, they shall be tested before use or
transfer. No sealed source shall be stored for a period of more than 10 years without being tested for leakage and/or contamination.
D. The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test
sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be
filed with the U.S. Nuclear Regulatory Commission in accordance with 10 CFR 30.50(c)(2), and the source shall be removed
immediately from service and decontaminated, repaired, or disposed of in accordance with Commission regulations.
E.
Analysis of leak test samples and/or contamination shall be performed by persons specifically licensed by the U.S. Nuclear Regulatory
Commission or an Agreement State to perform such services. The licensee is authorized to collect leak test samples but not perform
the analysis.
F.
Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 years.
14. Sealed sources or source rods containing licensed material shall not be opened or sources removed from source holders or detached from
source rods by the licensee, except as specifically authorized.
15. The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory
Commission, to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be
maintained for 3 years from the date of each inventory, and shall include the radionuclides, quantities, manufacturer's name and model
numbers, and the date of the inventory.
16. Except for maintaining labeling as required by 10 CFR Part 20, or Part 71, the licensee shall obtain authorization from the U.S. Nuclear
Regulatory Commission before making any changes in the sealed source, device, or source-device combination that would alter the
description or specifications as indicated in the respective certificate of registration issued either by the U.S. Nuclear Regulatory
Commission pursuant to 10 CFR 32.210 or by an Agreement State.
License No.:
Docket or Reference No.:
U.S. NUCLEAR REGULATORY COMMISSION
MATERIALS LICENSE
SUPPLEMENTARY SHEET
PAGES
OF
PAGE
5
4
50-29439-01
030-38522
Amendment No. 3
17. Each portable nuclear gauge shall have a lock or outer locked container designed to prevent unauthorized or accidental removal of the
sealed source from its shielded position. The gauge or its container must be locked when in transport or storage, or when not under the
direct surveillance of an authorized user.
18. Any cleaning, maintenance, or repair of the gauge(s) that requires detaching the source or source rod from the gauge shall be performed
only by the manufacturer or by other persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to
perform such services.
19. The licensee will continue to take all actions within its ability to dispose of its material and notify NRC within 30 days if disposal is achieved.
License No.:
Docket or Reference No.:
U.S. NUCLEAR REGULATORY COMMISSION
MATERIALS LICENSE
SUPPLEMENTARY SHEET
PAGES
OF
PAGE
5
5
50-29439-01
030-38522
Amendment No. 3
20. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements,
representations, and procedures contained in the documents, including any enclosures, listed below. This license condition applies only to
those procedures that are required to be submitted in accordance with the regulations. The U.S. Nuclear Regulatory Commission's
regulations shall govern unless the statements, representations, and procedures in the licensee's application and correspondence are
more restrictive than the regulations.
A. Application dated February 25, 2012 (ML12067A168)
B. Letter dated March 9, 2012 (ML12075A225)
C. Letter dated October 26, 2018 with attachments (ML18299A291)
D. Application and letter dated March 30, 2022 (ML22090A069)
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
By:
Date:
Roberto J. Torres
Region IV
March 31, 2022
Roberto J. Torres
Digitally signed by Roberto J.