1 Turkey Point Unit 3 and Unit 4 Reactor Protection System Engineered Safety Feature Actuation System Nuclear Instrumentation System Replacements Non-proprietary information suitable for public disclosure Safety System Replacement Project LAR Eighth NRC Pre-submittal Meeting OPEN SESSION March 7, 2022
2 OPEN SESSION Participant Introduction Background / meeting purpose Implementation Outage Schedule LAR supplements Human Factors Plan Changes CLOSED SESSION Life Cycle Phase Schedule Human Factors Information Availability Comments / Questions Agenda Non-proprietary information suitable for public disclosure
3 Florida Power & Light Contract and Support Introductions - On the Call today
- FPL Nuclear Licensing
- Steve Catron - Licensing Fleet Manager
- Jarrett Mack - Fleet Licensing Lead
- David Stoia - Turkey Point Licensing Lead
- Bill Maher - Improved Technical Specification Project Director
- FPL Nuclear Engineering
- Brian Dunn - Director - Fleet Design
- Phillip Barnes - Design Manager
- Wesley Frewin - Digital Design Supervisor
- Erik Gonzalez - Simulator Engineer
- Warren Busch - Project Engineer
- FPL PTN Operations
- Jim Goodrich - Unit Supervisor
- Brian Haynes - Licensing Lead
- Jacek Novakowski - Human Factors Lead
- Taha Abdelnaeem - Engineering Lead
- Ted Quinn - Licensing Engineer
- Bill Hannaman - Licensing Engineer (HFE)
- Sargent & Lundy (3rd Party review)
- Pareez Golub
- John McCague Non-proprietary information suitable for public disclosure
4 Background/Meeting Purpose Non-proprietary information suitable for public disclosure License Amendment Request for Turkey Point Units 3 & 4 Reactor Protection, Engineered Safety Feature Actuation System, and Nuclear Instrumentation System Replacements Seven Pre-submittal meetings to date discussing:
Vendor Oversight Plan (1/13/21, 2/18/21, 4/8/21, 7/22/21, 8/23/21)
ISG-06 Rev 2 process / LAR content (12/9/20, 1/13/21, 6/9/21, 7/22/21, 8/23/21)
Protection System Architecture (2/18/21, 4/8/21)
Human System Interface (12/9/20, 4/8/21)
Human Factors Engineering Program Plan (12/9/20, 4/8/21, 8/25/21)
Cyber Security (4/8/21)
Surveillance Reduction (4/8/21, 8/25/21)
Diversity and Design in Depth Evaluation (2/18/21, 6/9/21, 7/22/21, 8/25/21)
Diverse Actuation System (2/18/21, 7/22/21 )
Equipment Qualification and Dedication (8/25/21)
LAR / Life Cycle Phase Schedule (2/18/21, 4/8/21, 6/9/21, 8/25/21)
Observation Meeting. Availability of Human Factors Engineering (HFE)
Information, 2/2/2022 Purpose is to update the schedule for replacement Protection System development and implementation, LAR and LAR supplement submittals and HFE activities
5 Implementation Outage Schedule Lead Unit 3 Installed in Fall 2024 Following Unit 4 Installed in Spring 2025 Requested SER Issuance 2nd Quarter 2024 Non-proprietary information suitable for public disclosure 2024 FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC JAN FEB MAR APR MAY 2025 RFO 334 RequestedSERIssuance U3EquipmentOnSite U4EquipmentOnSite 6Months 6Months RFO 435 Notes:TimelineresolutionisMonthtoMonth Durationsandtargetsareforplanning Outagedurationisnotrepresentative RFO(RefuelingOutage)
Unit3 Unit4 TURKEYPOINTUNITS3&4PROTECTIONSYSTEMREPLACEMENTINSTALLATIONTIMELINE
6 Licensing Amendment Request (LAR) and Supplements LAR Submittal (2nd Quarter 2022)
- ISG-06 Revision 2 basis for LAR content LAR Supplements
- Surveillance Reduction (December 2022)
- Equipment Qualification (June 2023)
- ITS Tech Spec Mark-ups (October 2023)
Requested SER issuance (April 2024)
Non-proprietary information suitable for public disclosure
7 Human Factors Engineering - Plan Changes Adjusted based on NRC review approach discussed 2/2/22 Conformance to NUREG-0711 Rev. 3 maintained Recognition of Pre-and Post - Safety Evaluation Activities Three successive, coordinated validation review points
- Conceptual Design Test - (PV1)
- Preliminary Design Test - (PV2)
- Integrated System Validation (ISV)
Combination of Full Scope Glass Top Simulator and modified U3 Certified Simulator Tracking Human Engineering Deficiencies (HED)
Increase in Coordination
- NRC, pre-submittal and post-submittal meetings
- Idaho National Laboratories / Industry Non-proprietary information suitable for public disclosure
8 Full Scope Glass Top Simulator Available for Project Use 4th Quarter 2022 Non-proprietary information suitable for public disclosure
9 Full Scope Glass Top Simulator Development and Testing Activities
- Dynamic display testing with functional plant model
- Testing of critical scenarios and draft operating procedures
- Testing of time critical operator actions
- Testing of system and component level failures
- Procedure development
- Operator training (partial)
Non-proprietary information suitable for public disclosure
10 End of Open Session Comments and Questions Non-proprietary information suitable for public disclosure