ML22059A760
| ML22059A760 | |
| Person / Time | |
|---|---|
| Site: | 07001113 |
| Issue date: | 02/28/2022 |
| From: | Murray S Global Nuclear Fuel |
| To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards |
| References | |
| M220030 | |
| Download: ML22059A760 (2) | |
Text
GNii=
Global Nuclear Fuel M220030
- February 28, 2022 Attn: Document Control Desk Director, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001
Subject:
GNF-A Semi-Annual Effluent Monitoring Report
References:
- 1) NRC License SNM-1097, Docket 70-1113
- 2) NRC Regulation 10 CFR 70.59
Dear Sir or Madam:
Global Nuclear Fuel Scott P. Murray Manager, Facility Licensing 3901 Castle Hayne Road P.O. Box 780 Wilmington, NC 28402 USA T (910) 819-5950 scott.murray@ge.com With respect to activities authorized by NRC License SNM-1097, the Global Nuclear Fuel-Americas, L.L.C. (GNF-A) facility in Wilmington, North Carolina hereby submits the semi-annual effluent monitoring report required by 1 O CFR 70.59 for the period of July through December 2021.
If you have any questions regarding this report, please contact me at (910) 819-5950.
Sincerely, Scf;f::jl!J~
Facility Licensing
. (;/
Attachment:
- 1) Semi-Annual Effluent Monitoring Report (July-December 2021) cc: NRC Region II Administrator, Atlanta, GA J. Rowley, USNRC, NMSS J. Rivera Ortiz, USNRC, All J. Hall, NCDHHS
- D. Crowley, NCDHHS S. Breitmaier, ANI SPM 22-012
SEMI-ANNUAL EFFLUENT REPORT Global Nuclear Fuel - Americas, LLC Wilmington, North Carolina NRC License SNM 1097, Docket# 70-1113 I.
GASEOUS EFFLUENT-PARTICULATE NUCLIDES QUANTITY CONCENTRATION (Cl)
(uCUcc)
U234 7.86E-08 4.37E-15 U235 3.35E-07 1.86E-16 U236 8.09E*09 4.51E-18 U238 1.14E-06 6.34E-16 TOTAL 9.34E-06 1 APPENDIXB LIMIT (uCUcc) 5 E-12 6 E-12 6 E-12 6 E-12 EXHAUST VOLUME=
1.80E+15 (cc) 2 Nuclide QUANTITY CONCENTRATION 1 APPENDIXB (Cl)
(pCUcc)
Limit (pCUcc)
H-3 3.38E*03 4.51E-11 1E-05 EXHAUST VOLUME,.
7.50E+13 (cc)
II. LIQUID EFFLUENT NUCLIDES QUANTITY CONCENTRATION 1 APPENDIXB LIMIT ICII fuCUcc)
(uCl/cc)
U234 5.94E-03 2.77E-0B 3E-07 U235 2.53E-04 1.1BE-09 3 E-07 U236 6.11E-06 2.86E-11 3 E-07 U238 8.60E-04 4.02E-09 3 E-07 TOTALU 7.05E-03
% of LIMIT 0.09%
0.00%
0.00%
0.01%
%of LIMIT 0.00%
% of LIMIT 9.24%
0.39%
0.01%
1.34%
TOTAL VOLUME OF LIQUID EFFLUENT*
2.14E+0B (liters)
Ill. ABNORMAL RELEASES Air Water Total
- Releases 0
0 0
Activity 0
0 0
Released (Cl)
IV.
SUMMARY
3 Max Release CEDE,total COE (Lung), total (uCl/cc)
(mreml (mrem)
Value 2.77E-OB 2.55E-02 2.13E-01 Limit 3.00E-07 25 25
% of Limit 9.24%
0.10%
0.85%
CEDE mrem 2.19E-02 7.82E-04 1.89E-05 2.66E-03 2.53E-02 CEDE (mrem) 1.13E-04 CEDE (mrem) 2.02E-06 1.23E-07 1.97E-09 2.65E-07 2.41E-06 July 2021 - December 2021 Fiscal Weeks 27-52 CDE(Lung) mrem 1.84E-01 8.52E-03 1.58E-04 2.22E-02 2.13E-01 CDE(Lun111 COE (Bone Surface)
(mrem)
(mrem) 1.2BE-06 2.94E-05 7.79E*0B 1.78E-OB 1.26E-09 2.86E-08 1.69E*07 3.84E-06 1.52E-06 3.50E-05 1 Limit from 10 CFR 20 Appendix B, Table 2, Columns 1 and 2. Air limit adjusted to reflect NRC License SNM-1097, Section 1.3.9.
2 This nuclide Is Included due to the the neutron generator licensed by the State of North Carolina.
i From nuclide with release that is the largest percentage of Its release limit.
Notes:
Air sampling is continuous. H-3 gaseous effluent is calculated. Water samples analyzed are representative, continuous composite samples of the process effluent stream.
Reported effluent concentration values are representative of the effluent concentration at the point of release and do not consider
..., 1.*:,r** t ~*,.
t' ~
. ':,,... i, ',
~-~-~~~