Rev.-
No.
Revision Prepared/
Date Checked/
Date Release NCS/
Date Release BAM/
Date 1
Chapter 7 and new W. Bergmann 14.10.2013 T. Breuer 14.10.2013 F. Hilbert 14.10.2013 C. Kuschke 24.10.2013 Publisher: Department AT Inspection Instruction No.: PA-03-04 Inspections of the BU-D Package within the Scope of Maintenance, of Regular and Periodic Inspections Contents
- 1. Object and field of application
- 2. Scope and date of inspections
- 3. Qualification of the inspection personnel
- 4. Documents
- 5. Conditions of visibility
- 6. Inspection performance, assessment and evaluation 6.1 Visual inspections 6.2 Wall thickness measurement 6.3 Inspection of threads with gauge ring and plug
- 7. Special information for repair measures 7.1 Repair of paint damages 7.2 Removal of corrosion at the insulating disc 7.3 Repair of the thermal insulation 7.4 Cleaning of the thread holes of the hexagon nuts of the inner container
- 8. Documentation : Inspection criteria : Sample template for the repair of the light concrete surface
Inspection Instruction No. PA-03-04 Rev. 1 Page 2 of 6
- 1.
Object and field of application The object of these inspection instructions is to determine the conditions for the in-spection of transport casks of type BU-D within the scope of maintenance and period-ic inspections. Furthermore the instruction contains requirements for repair measures.
- 2.
Scope and date of inspections Scope and date of inspections are defined in the higher ranking instruction.
- 3.
Qualification of the inspection personnel Personnel carrying out inspections must be familiar with the inspection instructions and the drawings of the transport cask and must be capable of carrying out visual in-spections.
Furthermore, the requirements put forward in the higher ranking instruction are valid.
- 4.
Documents The drawings and parts list belonging to the cask have to be available for the regular and periodic inspections. During the maintenance within the scope of handling these have to be taken into regard for the evaluation of unacceptable inspection results.
- 5.
Conditions of visibility Good illumination must prevail at the inspection site at the time of inspections, e.g.
daylight or artificial light of 500 Lux at least (this corresponds to lighting conditions 1 m from an 80 W fluorescent lamp). Disturbing light influences, e.g. reflections, are not allowed.
- 6.
Inspection performance, assessment and evaluation 6.1 Visual inspections The various components of the transport cask are submitted to visual inspection covering:
x Cleanliness x
Condition of the paint x
Surface conditions x
Irregularities and damages x
Corrosion x
Completeness The criteria for visual inspections are found in the drawings and parts lists as well as in the instructions in Attachment 1 to these instructions.
If any dents are found during the visual inspection, which apparently are within the admissible scope of error, they shall be measured with a steel ruler and a slide gauge.
6.2 Wall thickness measurement Wall thickness shall be checked randomly on 5 % of the transport casks to be in-spected, using an adequate ultrasound wall thickness measuring unit.
Inspection Instruction No. PA-03-04 Rev. 1 Page 3 of 6 Three points each on the exterior package and on the interior package shall be de-termined randomly. The allowable deviations of the wall thickness are specified in At-tachment 1.
6.3 Inspection of threads with gauge ring and plug The threads are inspected for:
x Cleanliness x
Mechanical damages x
Dimensional accuracy of the threads The criteria for the inspections have to be taken from DIN ISO 1502, the instructions in Attachment I and the instructions of the higher ranking instruction.
- 7.
Special information for repair measures 7.1 Repair of paint damages For the repair of paint damages at the outer and inner container respectively for new painting only paints may be used for which a certificate according to DIN 25415 or ISO 8690 exists which certifies at least good decontamination properties.
The information of the manufacturer has to be observed during painting.
7.2 Removal of corrosion at the insulating disc If corrosions are detected at the zinc-coated plates of the insulating disc these have to be removed for example by sandpapering. After this the insulating disc has to be painted with a primer coat if necessary.
7.3 Repair of the thermal insulation If cracks or spalling at the surface of the thermal insulation between inner and outer container are detected these have to be repaired.
For this the concrete at the affected area is largely removed and repaired by applying new light concrete at the surface. To get an even, smooth surface it is recommended to use a template according to Attachment 2.
When mixing the light concrete as far as possible the composition of perlite, cement and water according to material data sheet WB-02-04 has to be observed. The use of tylose and air-entraining agent is not necessary because these are only necessary for the better pouring of the complete container but not for surface repair.
After the repair of the light concrete surface it has to dry at least for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. After this the surface has to be sealed with decontamination paint.
7.4 Cleaning of the thread holes of the hexagon nuts of the inner container The threads of the hexagon nuts of the inner container can get dirty with residues of the light concrete. These residues have to be removed especially for the gauge test.
To prevent a damage of the threads during the cleaning this should be done as con-serving as possible by brushing and exhausting of the residues. In the case of bond-
Inspection Instruction No. PA-03-04 Rev. 1 Page 4 of 6 ed adhesions the thread should be cleaned manually with a die. It has to be paid at-tention to the correct positioning of the die.
- 8.
Documentation The results of inspections shall be recorded when this is required in the higher rank-ing instructions. If overhauling tasks are required (with exception of cleaning works),
they also have to be documented.
Inspection Instruction No. PA-03-04 Rev. 1 Page 5 of 6
- Inspection criteria
Inspection criteria PA-Nr. PA-03-04 Page 1 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Package identification Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Package identification Legibility Illegible signs Restore readability by painting Completeness Missing signs Correct signs with stencil Conformance with package log book Deviations Correct package marking with stencil
Inspection criteria PA-Nr. PA-03-04 Page 2 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Outer container Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Basic body (outer surface and accessible inner surface)
Surface conditions Maintenance Dirt, if it can impair the function of the package Regular and periodic inspections Dirt Cleaning Maintenance Damaged paint (cracks, flaking) with an extension greater than 1 cm2 Regular and periodic inspections Damaged paint (cracks, flaking)
Repair painting Maintenance Signs of corrosion with an extension greater than 1 cm2 Regular and periodic Inspections Signs of corrosion Derust, repair painting In case of significant material abrasion perform a wall thickness measurement and record in the package log book; If the measured wall thickness is more than 25 % below the requirements of the drawings the cask has to be separated resp. repair measures have to be agreed with BAM Mechanical damages Holes and cracks, dents with a depth greater 30 mm, sharp edges Separate cask resp. agree with BAM on repair measures Wall thickness Wall thickness is below 25 % of the nominal wall thickness Separate cask resp. agree with BAM on repair measures Lid (outer and inner surface)
Surface conditions Maintenance Dirt, if it can impair the function of the package Regular and periodic Cleaning
Inspection criteria PA-Nr. PA-03-04 Page 3 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Outer container inspections: Dirt Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Maintenance Damaged paint (cracks, flaking) with an extension greater than 1 cm2 Regular and periodic inspections Damaged paint (cracks, flaking)
Repair painting Maintenance Signs of corrosion with an extension greater than 1 cm2 Regular and periodic Inspections Signs of corrosion Derust, repair painting In case of significant material abrasion perform a wall thickness measurement and record in the package log book; If the measured wall thickness is more than 25 % below the requirements of the drawings replace the lid Mechanical damages Holes and cracks, dents with a depth greater 30 mm, sharp edges Replace lid Wall thickness Wall thickness is below 25 % of the nominal wall thickness Replace lid Gasket Cleanliness Dirt Cleaning General condition Damages, cracks Replace gasket
Inspection criteria PA-Nr. PA-03-04 Page 4 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Outer container Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Clamping ring Surface conditions Maintenance Dirt, if it can impair the function of the package Regular and periodic inspections:
Dirt Cleaning Maintenance Signs of corrosion with an extension greater than 1 cm2 Regular and periodic Inspections Signs of corrosion Replace clamping ring Mechanical damages Holes, cracks, deformations Replace clamping ring Clamping ring screw Surface conditions Signs of corrosion, which may impair the function Replace clamping ring screw Mechanical damages Damaged threads and screw heads Replace clamping ring screw
Inspection criteria PA-Nr. PA-03-04 Page 5 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Insulating disk Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Surface Surface conditions Dirt Cleaning Signs of corrosion and damages of the surface coating (white discolouration are acceptable)
Derust; in case the function is impaired replace part Mechanical damages Holes and cracks, dents with a depth greater 30 mm, holes, cracks Replace part
Inspection criteria PA-Nr. PA-03-04 Page 6 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Inner container Part Inspection for:
Unacceptable are:
Measures in case of non-conformities Inner cavity Surface conditions Dirt Cleaning Damaged paint (cracks, flaking)
Repair paint Signs of corrosion Derust, repair painting In case of significant material abrasion perform a wall thickness measurement and record in the package log book; If the measured wall thickness is more than 25 % below the requirements of the drawings the cask has to be separated resp. repair measures have to be agreed with BAM Mechanical damages Holes and cracks, dents with a depth greater 30 mm, sharp edges Separate cask resp. agree with BAM on repair measures Wall thickness Wall thickness is below 25 % of the nominal wall thickness Separate cask resp. agree with BAM on repair measures Sealing surface Surface conditions Dirt Cleaning Damage of paint (cracks, flaking)
Repair paint Signs of corrosion Derust, repair coating Mechanical damages Notches, furrows, scratches in the metallic base material larger than 20 mm transversally in relation to the gasket Separate cask resp. agree with BAM on repair measures Lid (outer and inner surface)
Surface conditions Dirt Cleaning Damage of paint (cracks, Repair paint
Inspection criteria PA-Nr. PA-03-04 Page 7 of 7 Inspection instructions: PA-03-04, Rev. 1 Rev. No. Revision Prepared/Date Checked/Date Release NCS/
Date Release BAM/
Date 0
1 Original PA-03-04 Rev. 1 W. Bergmann/
11.04.2003 W. Bergmann 14.10.2013 F. Hilbert/
14.04.2003 T. Breuer 14.10.2013 M. Kübel/
15.04.2003 F. Hilbert 14.10.2013 T. Nitz 05.02.2004 C. Kuschke 24.10.2013 Component:
Inner container Part Inspection for:
Unacceptable are:
Measures in case of non-conformities flaking)
Signs of corrosion Derust, repair painting In case of significant material abrasion perform a wall thickness measurement and record in the package log book; If the measured wall thickness is more than 10 % below the requirements of the drawings replace the lid Mechanical damages Holes and cracks, dents with a depth greater 5 mm Replace lid Wall thickness Wall thickness is below 25 % of the nominal wall thickness Replace lid Gasket Cleanliness Dirt Cleaning General condition Damages, cracks Replace gasket Fastening to the lid Damaged fastening Glue gasket to lid Screws and thread holes Surface conditions Signs of corrosion Replace screws, Rethread, if the tolerances specified in the higher ranking instructions are exceeded repair with Helicoil insert Mechanical damages Damaged threads and screw heads Replace screws, Rethread, if the tolerances specified in the higher ranking instructions are exceeded repair with Helicoil insert
Inspection Instruction No. PA-03-04 Rev. 1 Page 6 of 6
- Sample template for the repair of the light concrete surface
'DWXP 1DPH
,QGH[5HYLVLRQ'DWXP1DPH 3URMHNWSURMHFW
%HQHQQXQJWLWOH
0DVWDE VFDOH
=HLFKQXQJV1UGUDZLQJQR
)RUPDW
- H]HLFKQHW
- HSUIW
$
$OOJHPHLQWROHUDQ]HQQDFK',1,62P.
6FKZHLWROHUDQ]HQQDFK',1(1,62%(
2EHUIOlFKHQEHVFKDIIHQKHLWQDFK',1(1,62
)RUPXQG/DJHWROHULHUXQJQDFK',1,62
8UKHUEHUUHFKWQDFK',1,62
- HQHUDOWROHUDQFHVDFFWR',1,62P.
- HOGLQJWROHUDQFHVDFFWR',1(1,62%(
6XUIDFHWH[WXUHDFFWR',1(1,62
- HRPHWULFDOWROHUDQFLQJDFFWR',1,62
&RS\\ULJKWDFFWR',1,62
'LHVH=HLFKQXQJZXUGHPLWWHOV&$'HUVWHOOWXQGJHSORWWHW'LH=HLFKQXQJVJUlHNDQQGDKHUYRQGHU2UJLQDO]HLFKQXQJDEZHLFKHQ
7KLVGUDZLQJZDVPDGHDQGSORWWHGE\\XVLQJ&$'7KHGUDZLQJVL]HPD\\WKHUHIRUHGLIIHUIURPWKHRULJLQDOVL]H
18&/($5
&$5*26(59,&(
1&6
'$+(5 Bergmann Korn 30.09.
30.09.
Behlter BU-D 1:2 1:1 Formschablone 2 für Betonreparatur am Behlter BU-D 1-270-031-10-00