January 6, 2022 MEMORANDUM TO:

Steven Lynch, Chief Advanced Reactor Policy Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Joseph M. Sebrosky, Senior Project Manager Advanced Reactor Policy Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF DECEMBER 14, 2021, PUBLIC MEETING TO DISCUSS TECHNOLOGY INCLUSIVE CONTENT OF APPLICATION PROJECT On December 14, 2021, the U.S. Nuclear Regulatory Commission (NRC) staff held a public meeting with stakeholders to discuss the technology inclusive content of application project (TICAP). The meeting notice is available in the NRCs Agencywide Documents Access and Management System (ADAMS) at Accession No. ML21344A142, and the presentation slides are available at ADAMS Accession No. ML21344A006. The enclosure to this summary provides the attendees for the meeting as captured by Microsoft Teams.

The purpose of this meeting was to discuss with stakeholders issues related to the Nuclear Energy Institute (NEI) Technical Report 21-07, Revision 0-B, Technology Inclusive Guidance for Non-Light Water Reactors Safety Analysis Report Content for Applicants Using the NEI 18-04 Methodology (ADAMS Accession No. ML21343A292). This meeting was a follow-on meeting to previous public TICAP meetings held on:

May 11, 2021 (meeting summary available in ADAMS at Accession No. ML21132A295)

May 19, 2021 (meeting summary available in ADAMS at Accession No. ML21154A290)

May 26, 2021 (meeting summary available in ADAMS at Accession No. ML21158A223)

June 23, 2021 (meeting summary available in ADAMS at Accession No. ML21181A335)

August 17, 2021 (meeting summary available in ADAMS at Accession No. ML21245A442)

October 5, 2021 (meeting summary available in ADAMS at Accession No. ML21301A189)

November 9, 2021 (meeting summary available in ADAMS at Accession No. ML21328A233)

CONTACT: Joseph Sebrosky, NRR/DANU 301-415-1132 Signed by Sebros on 01/06/22

S. Lynch 2

During the meeting, the NRC staff referred to the TICAP Regulatory Guide draft white paper dated December 2, 2021, (ADAMS Accession No. ML21336A697) that provided an update to an earlier version of the draft white paper based on the staffs review of NEI 21-07, Revision 0 (ADAMS Accession No. ML21250A378). The NRC staff and industry also discussed NEI 21-07, Revision 0-B that was provided to the staff on December 8, 2021. The December 8, 2021, document included changes to address NRC staff comments provided to industry that were discussed during the November 9, 2021, TICAP meeting referenced above.

Meeting Highlights

The NRC staff outlined its position on developing principal design criteria (PDC) using a licensing modernization project (LMP) based approach and provided a set of recommendations for industry to consider in the next revision to NEI 21-07. Highlights of the NRC staffs PDC position included:

o The NRC staffs position is that the requirement to propose PDCs extends to the scope of PDC (i.e., design, fabrication, testing, inspection, and performance requirements) and that applicants may request an exemption if the proposed PDCs do not fully address the scope of PDC.

o In addition, NRC staff clarified that to ensure proposed PDC covered the required important to safety structures, systems, and components (SSCs), the LMP-developed PDCs must address both safety-related SSCs and non-safety related with special treatment SSCs. Further, the NRC staff stated that the proposed two-tiered PDC complimentary design criteria (CDC) approach outlined in NEI 21-07 should be consolidated into just PDCs (e.g., could include PDC Type A and PDC Type B).

o To meet the underlying requirement for the development of PDC, the NRC staff stated that the PDC must cover the scope of the general design criteria (GDC) found in Title 10 of the Code of Federal Regulations (10 CFR) Part 50 Appendix A including SSCs considered important to safety and PDC associated with normal operations (e.g., design criteria to ensure normal effluent release requirements, and occupational dose requirements are met).

Industry stated that it would consider the NRC staffs position and would provide a plan to the staff in early January on how it intends to address the issue. The plan will be discussed in the next TICAP public meeting tentatively scheduled for January 18, 2022.

Another high-priority item for the meeting was the level of information to be captured in the safety analysis report (SAR) relative to anticipated operational occurrences (AOO), design basis events (DBE), and beyond design basis events (BDBE).

o The NRC staffs position is that the SAR should contain important supporting data that is significant to the development of the AOO, DBE, and BDBE analyses conclusions regarding risk significance, meeting frequency consequence curve targets or quantitative health objectives (QHOs), developing SSC classification, or evaluating defense-in-depth.

The NRC staff stated that such information is needed in the SAR to support its regulatory findings and to ensure important information is captured in the SAR to assess changes to the plant made during the operational phase.

S. Lynch 3

o Industry stated that this information is captured in the probabilistic risk assessment (PRA) and it is not necessary to elevate this information to the SAR.

o The NRC staff and industry agreed to develop examples, potentially using the outcome of recent TICAP tabletop exercises, to identify significant supporting AOO, DBE, and BDBE data that should be captured in the SAR.

Other action items from the meeting included:

o Industry will provide comments on the NRC staffs draft TICAP regulatory guide white paper prior to the next TICAP meeting.

o NRC staff will provide feedback on which of the staffs proposed exceptions, clarifications, and additions associated with NEI 21-07 are resolved based on the December 8, 2021, NEI 21-07 revision 0-B.

Enclosure:

Attendance List

S. Lynch 4

SUBJECT:

SUMMARY

OF DECEMBER 14, 2021, PUBLIC MEETING TO DISCUSS TECHNOLOGY INCLUSIVE CONTENT OF APPLICATION PROJECT DATED: JANUARY 6, 2022 DISTRIBUTION:

PUBLIC RidsNrrDanu Resource RidsNrrDanuUarp Resource JSegala SLynch JSebrosky EOesterle ADAMS Accession Number: ML21354A833 NRC-001 OFFICE NRR/DANU/UARP/PM NRR/DANU/UARP/BC NRR/DANU/UARP/PM NAME JSebrosky SLynch JSebrosky DATE 12/21/2021 1/6/2022 1/6/2022 OFFICIAL RECORD COPY

Enclosure December 14, 2021, Public Meeting to Discuss Technology Inclusive Content of Application Project Attendance List*

NAME AFFILIATION NAME AFFILIATION John Segala NRC/NRR/DANU Amir Afzali Southern Company Martin Stutzke NRC/NRR/DANU Brandon Chisholm Southern Company Steven Lynch NRC/NRR/DANU/UARP Ben Holtzman Nuclear Energy Institute (NEI)

William Reckley NRC/NRR/DANU/UARP Cyril Draffin U.S. Nuclear Industry Council Eric Oesterle NRC/NRR/DANU/UARP Steven Nesbit LMNT Consulting Jordan Hoellman NRC/NRR/DANU/UARP Ed Wallace GNBC Associates Joe Sebrosky NRC/NRR/DANU/UARP Neil Haggerty Excel Prosanta Chowdhury NRC/NRR/DANU/UARP Frank Akstulewicz A to Z Reactor Consulting Services Maryam Khan NRC/NRR/DANU/UARP Dennis Henneke GE Power Stephen Philpott NRC/NRR/DANU/UARP Denise Brooks GE Power Arlon Costa NRC/NRR/DANU/UARP Scott Ingalls GE Power Amy Cubbage NRC/NRR/DANU/UARP Karl Fleming KNF Consulting Binesh Tharakan NRC/NRR/DANU/UARP Raymond Wang X-energy Beth Reed NRC/NRR/DANU/UARP Jon Facemire X-energy Michael Orenak NRR/NRR/DANU/UTB1 Brandon Hartle X-energy Hosung Ahn NRC/NRR/DANU/UTB1 Steve Vaughn X-energy Alexander Chereskin NRC/NRR/DANU/UTB1 Charlotte Geiger X-energy Alexandra Siwy NRC/NRR/DANU/UTB2 George Wilson TerraPower Jeffrey Schmidt NRC/NRR/DANU/UTB2 Bryan Eyers TerraPower Ben Adams NRC/NRR/DANU/UTB1 Ryan Sprengel TerraPower Christopher Van Wert NRC/NRR/DANU/UTB1 Sean Morrell NuScale Timothy Lupold NRC/NRR/DANU/UTB1 Amanda Spalding Westinghouse Ian Jung NRC/NRR/DANU/UTB1 George Flanagan ORNL Ed Miller NRC/NRR/DORL/LPL2-1 William Winslow U.S. Army Robert Roche-Rivera NRC/RES/DE/RGPMB Andrew Zach Senate Committee on Environment and Public Works Shakur Walker NRC/COMM/DW Dave Grabaskas Argonne National Lab Henry Marchiewski OCHCO/ADHRTD/NRANB Adam Stein Breakthrough Institute Scott Bussey OCHCO/ADHRTD/RTTB Farshid Shahrokhi Not Available (NA)

Bob Weisman NRC/OGC Richard Paese NA Carolyn Wolf NRC/OCA Frank Schaaf NA Derek Widmayer NRC/ACRS Lisa Peterson NA Jim Kinsey INL Tom Seewald NA Chris Chwasz INL Paul Loza NA Tom King INL Ben Chen NA Tom Hicks INL Rob Burg NA Ewa Muzikova NA Jason Andrus NA

2 NAME AFFILIATION NAME AFFILIATION Steven Pope NA Alan Levin NA Martin ONeill NA Chris Robinson NA Robert Youngblood NA Kiersten Smith NA Don Williams NA Kurt Harris NA Altheia Wyche NA Cindy Williams NA Mike Tschiltz NA Bruce Weir NA Ian Gifford NA

  • Attendance list based on Microsoft Teams Participant list. List does not include 7 individuals that connected via phone.