1 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved NRC Pre-Application Meeting TN-B1 Package Amendment And Letter Authorization Docket No. 9372 November 29, 2021

© Framatome All right reserved

2 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

1. Purpose of Changes
2. Package Amendment
3. Letter Authorization
4. Proposed Schedule
5. Questions Agenda

3 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Support Channeled ATRIUM 11 Fuel Transport

Framatome recently issued a 10 CFR 71.95 Report for fuel channel side thickness exceeding maximum dimension during Browns Ferry reload

Latest Brunswick transport experienced unacceptable vibration

Improve shock isolating system within inner and outer container (multiple materials)

71.95 Report issued on exceeded fuel channel side thickness.

Miscellaneous Improvement

New Criticality Evaluation to address fuel assembly rotational orientation

Incorporate h_poly cross section SCALE errors identified by ORNL

Allow additional Inner and Outer container lid gasket materials

Protective rubber strip near forklift pockets and bolsters to be made optional Letter Authorization

Support March 2022 road tests utilizing enriched fuel assemblies to confirm vibration performance of multiple rubber options

Increase allowable fuel channel side thickness

Incorporate h_poly cross section SCALE errors identified by ORNL

Allow multiple rubber types within the inner container and shock isolation system Purpose

4 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

TN-B1 Packaging

5 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

Outer Container Shock Isolator Changes Rubber pads (4 assemblies per side)

Shock Isolators (4 assemblies per side)

6 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

Outer Container Shock Isolator Changes

Shock Isolator Material

Currently defined as natural rubber

Change material options to include synthetic rubber by eliminating natural

No primary safety function, used to maintain fuel assembly quality

Allow size variation, square versus round

Includes Drawing and Text Changes

From Natural Rubber to Rubber

SAR Drawing 105E3740, Item 9 (shock Isolator)

SAR Drawing 105E3739, Items 7, 8, 11 (rubber pads)

Add note to each drawing allowing size and shape variation

Section 2.2.2, Chemical, Galvanic, or Other Reactions (3 places)

Rubber to be defined as neoprene, butyl, nitrile, natural or synthetic type rubbers

Provide table with maximum defining limits (TBD) based on fuel assembly material control program

For example: Bromine = 150 ppm, Chlorides = 150 ppm, Fluorides = 150 ppm, Sulfur = 350 ppm

7 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

Synthetic Rubber Vibration Performance

8 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

Inner Container Allowable Foam Changes Revise to allow multiple types of rubber on any side

9 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Packaging Amendment

Inner Container Foam Changes

Foam Absorber Pad Under Fuel Assembly

Currently defined as Polyethylene Foam

Change material options to include Polyethylene Foam or discontinuous strips of rubber

Used to maintain fuel assembly quality, no change for NCT or HAC drops

Includes Drawing and Text Change(s)

SAR Drawing 105E3745, Item 40

From Polyethylene Foam to Polyethylene Foam or Rubber

Rubber to be defined as neoprene, butyl, nitrile, natural or synthetic type rubbers

Within inner container, all foam and rubber to be limited by minimum overall thickness and a maximum density to allow for multiple vibration configurations.

1.2, Package Description

2.2, Materials / Structural

No effect, changes provide consistent function for vibration control

3.5, Thermal HAC

No effect, conservatively not modeled

6.1, Criticality Design, 6.12, 11x11 Criticality Design

New maximum allowable density to be defined

7.4, Maintenance, Other Operations (no effective change)

10 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

Outer and Inner Container Lid Gaskets Packaging Amendment

11 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

Outer and Inner Container Lid Gaskets

Gasket

Currently defined as Natural Rubber

Change material options to Rubber or Neoprene

No safety function, purpose of gasket is for dust seal not pressure retaining seal (Section 2.12.3)

Containment boundary is the fuel assembly cladding

Includes Drawing and Text Changes

105E3743, Item 12 (outer container gasket)

105E3743, Items 10 and 14 (inner container end lid gaskets)

105E3747, Items 17, 21 (inner container gaskets)

From Natural Rubber to Rubber or Neoprene

Material discussion in 2.2.2, Chemical, Galvanic, or Other Reactions

Compression discussion in 2.12.3, Outer Container Gasket Sealing Capability Packaging Amendment

12 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

Outer Container Protective Pad Packaging Amendment 4 Locations (2 per side)

13 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

Outer Container Protective Pads

Protective Pad on outside of container above fork pockets and bottom of bolsters

Currently defined as natural rubber

Change material options to include rubber or neoprene

No safety function, clarify pads are optional

Drawing Changes

105E3738, Items 27, 28, 29, 39

From Natural Rubber to Rubber or Neoprene

Clarify Flag Note 10; Rubber pad is optional

No Text Changes Needed Packaging Amendment

14 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

New Criticality Evaluations

Fuel Assembly orientation

Currently, the Fuel Assembly orientation is for a single orientation and is controlled by administrative procedure for axial rotation

Fuel Channel Side Thickness

Increase 11 x 11 allowable fuel channel thickness to <0.315 cm from <0.254 cm

Incorporate h_poly Cross Section SCALE Errors Identified by ORNL

Include penalty for h_poly cross section error

Inner Container

Additional materials allowed including neoprene, butyl, natural or synthetic type rubbers

Additional materials are bounded by polyethylene in the criticality evaluation

Chapter 6 Changes

New evaluation for fuel orientation

Revise existing evaluation and Chapter 6 information to increase allowable channel thickness

Criticality evaluation to establish maximum density conservatively based on polyethelene

New CSI value

CSI =1.5 (from 1.0)

Change is due to allowable fuel assembly rotation Packaging Amendment

15 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved

Letter Authorization Items

Minimum Changes Needed to Support Road Tests for Channeled 11x11 Fuel Assemblies

Maximum of two shipments (2nd based on results of 1st test)

Each shipment will include up to three TN-B1 packages each with up to two channeled fuel assemblies

Up to 6 channeled fuel assemblies per shipment

Will include additional empty packages

Replace Shock Isolator Material and Pad Sizes

Change material options to include synthetic rubber by eliminating natural

Allow variable sizes for shock isolator and pads

Inner Container Foam Absorber Pad Under Fuel Assembly

Change material options to include rubber

Criticality evaluation to establish maximum density conservatively based on polyethelene

Fuel Channel Side Thickness

Increase allowable fuel channel thickness from <0.254 to <0.315 cm

Incorporate h_poly cross section SCALE errors identified by ORNL

No CSI change

CSI=1.0 (no change)

Letter Authorization does not include fuel rotation allowance Letter Authorization

16 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Proposed Schedule

17 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Questions/Discussion

?

18 TN-B1 License Amendment - November 29, 2021

© Framatome All right reserved Thank You