ML21326A270
ML21326A270 | |
Person / Time | |
---|---|
Issue date: | 08/22/2016 |
From: | Eam E Acquisition Management Division |
To: | Premier Management Corp |
References | |
GS00F0003X | |
Download: ML21326A270 (99) | |
Text
2 of 99
- 19. 20. 21. 22. 23. 24.
ITEM NO. SCHEDULE OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 32a. QUANTITY IN COLUMN 21 HAS BEEN RECEIVED INSPECTED ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED:
32b. SIGNATURE OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32e. MA LING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f. TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32g. E-MA L OF AUTHORIZED GOVERNMENT REPRESENTATIVE
- 33. SHIP NUMBER 34. VOUCHER NUMBER 35. AMOUNT VERIFIED 36. PAYMENT 37. CHECK NUMBER CORRECT FOR COMPLETE PARTIAL FINAL PARTIAL FINAL
- 38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY 41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT 42a. RECEIVED BY (Print) 41b. SIGNATURE AND TITLE OF CERTIFY NG OFFICER 41c. DATE 42b. RECEIVED AT (Location) 42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS STANDARD FORM 1449 (REV. 2/2012) BACK
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION B - Supplies or Services/Prices ........................................................................................................4 SECTION C - Description/Specifications ..........................................................................................................6 SECTION D - Packaging and Marking .............................................................................................................18 SECTION E - Inspection and Acceptance.......................................................................................................19 SECTION F - Deliveries or Performance .........................................................................................................20 SECTION G - Contract Administration Data ...................................................................................................21 SECTION H - Special Contract Requirements................................................................................................22 SECTION I - Contract Clauses .........................................................................................................................56 SECTION J - List of Documents, Exhibits and Other Attachments..............................................................88 ATTACHMENT 1 - Billing Instructions - Time-and-Materials/ Labor-Hour Type Contracts......................88 ATTACHMENT 2 - NRC Form 187 ...................................................................................................................96 Page 3 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION C - Description/Specifications Professional Development Center (PDC) Operations and Training Support Statement of Work (SOW)
C.1 Background The U.S. Nuclear Regulatory Commission (NRC) is an independent Federal agency whose mission is to license and regulate the Nations civilian use of byproduct, source, and special nuclear materials to ensure adequate protection of public health and safety, promote the common defense and security, and protect the environment. NRC staff license and inspect nuclear reactors, materials, and waste facilities to ensure compliance with applicable codes and standards during all phases of construction, testing, operation, and decommissioning.
The NRC provides classroom, self-study, web-based and blended learning training courses for its Federal employees in a variety of technical, professional and administrative areas, such as probabilistic risk assessment, health physics, information technology, leadership, finance, acquisition, human resources and communication. Most of these courses are provided by the Office of the Human Chief Capital Officer (OCHCO), Human Resources Training Development (HRTD) Division. The agencys classroom and distance education courses, including blended learning courses, are either off-the-shelf courses or custom designed for NRC staff by contractors and in-house staff.
The Professional Development Center (PDC) was established to support NRC in-house training requirements at its headquarters location in N. Bethesda, MD. The PDC facility is currently located within the NRCs 3 White Flint North (3WFN) building, on the second floor and was specially designed for the agency as part of the construction of the building (2012). The facility features 5 classrooms with a combined capacity of approximately 140 students and two computer lab training rooms with a combined capacity of 28 students.
Until recently the facility also included two multipurpose rooms that were used for small groups and/or meetings, but these rooms are currently being utilized as agency swing space. They may be converted back to PDC multipurpose rooms in several years. The PDC also includes a large student lounge area and kitchen, email checking stations, several telephones for local calls, a few technical exhibits, a library and storage room for training materials, two copier rooms, and work cubicles used primarily by PDC contractor staff.
The training classes held at the PDC are determined by the NRC and include NRC or contracted instructor-led courses as well as special learning events. On occasion, the PDC provides classroom instructors and materials to the NRCs regional sites or contractor facilities near those sites. NRC regional offices are currently located at King of Prussia, PA (Region 1), Atlanta, GA (Region II), Chicago, IL (Region III), Arlington, TX (Region IV), and Chattanooga, TN (Technical Training Center or TTC).
Blended Learning The NRC is increasing its use of both distance education and blended learning in order to allow the NRCs ever-increasing mobile workforce to access as much of their training as possible on an as-needed basis.
Blended learning is defined as using a combination of educational techniques to optimize knowledge transfer and delivery using both formal and informal approaches. Examples of various educational techniques include classroom instruction, videos, websites, virtual classrooms, discussion boards, modelling and simulation, webinars, communities of practice, and hands-on practical application of knowledge and practice of skills with the support and guidance of a mentor or learning coach. Blended learning is also used in professional development and training settings, as it can be used to translate knowledge into a particular skill that is useful and practical for a specific job. The terms "blended," "hybrid," "technology-mediated instruction," "web-enhanced instruction," and "mixed-mode instruction" are often used interchangeably. To achieve this mobility, the NRC relies on the agencys two-way video teleconferencing (VTC) system, GoToMeeting (the NRCs Page 6 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 webinar system), and Adobe Connect technology and videos. In the not-too-distant future, there may also be the use of VM Ware (virtual machine-remote login to computers) and satellite transmission for distance learning. In addition, online courses and learning aids - such as e-books - are available via the NRCs online Learning Management System (LMS) or iLearn as it is commonly known in the agency. Many of the agencys online and support tools are now available in mobile technology formats, such as those especially designed for tablets. As the use of technology in learning and development continues to increase, the agency is dedicated to providing the necessary platforms to support emerging technology requirements.
External Training (SF-182s)
In addition to the PDC and associated systems for the delivery of training, the NRC also provides employees with the opportunity to attend external training courses at typically local, government-approved training vendors, including the attendance of conferences. These external training courses and conferences are utilized when all in-house training options have been exhausted and the best way to develop the skill/competency of the employee is via an external training course. Once the external training course need has been determined and approved by the employees Supervisor the employee then submits an SF-182 or Request to Attend External Training document via the agencys LMS or iLearn system. The SF-182 is reviewed for accuracy and completeness by OCHCO/HRTD/Learning Operations and Process Improvement Branch (LOPIB) staff and, once approved, is routed to OCHCOs budget group for funding.
C.2 Objective The objective of this requirement is to provide contractor support services to assist and support the NRCs in-house (PDC) and external training (SF-182) processes as described below:
PDC facility operations; General administrative office support, such as providing class rosters to instructors and orderings supplies; Training delivery support at the PDC and Offsite locations (support provided remotely), including general IT support with webinars, GoToMeetings, Adobe Connect, VTC, videos and any other IT systems (e.g., VM Ware) as needed to support the training venue; Student record and course data maintenance in the LMS (iLearn); and Standard Form 182 (SF-182) - provide support to the external training process (for those NRC offices whose training function has been centralized in OCHCO) to include (1) review of external training requests for accuracy and completeness (2) verification that the training is on the approved training plan, and (3) registration of approved SF-182s.
The above-referenced items shall be accomplished in a professional, complete, and accurate manner that supports the overall goal of providing training support to the agency as described herein.
C.3 Scope of Work/Tasks The contractor shall provide all resources necessary (personnel, equipment and material) to accomplish the tasks and deliverables described in this Statement of Work (SOW). Services and tasks to be performed by the contractor are detailed below.
C.3.1 Operation of the PDC Facility and General Administrative Support The contractor shall provide continuous oversight and control in operating the PDC facility and classrooms, including a full range of IT services to support distance or blended learning.
Page 7 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- a. At least one contractor staff member shall arrive daily at the PDC by 7:00 a.m. to set up classrooms and turn on AV equipment, classroom computers, and podiums. At least one contractor staff member shall remain at the facility until 4:45 p.m. to ensure all classrooms are properly shut down and all AV equipment and classrooms computers are turned off.
- b. The contractor shall operate the PDC for onsite classes from 8:00 a.m. to 4:15 p.m. every day that the Federal Government is open for business. When the Government experiences a delayed opening, the entire contractor staff shall arrive at least 30 to 45 minutes before the scheduled opening.
- c. The contractor shall protect NRC property and facilities by using and abiding by all NRC security requirements such as closing and locking doors. The contractor shall ensure that all equipment such as laptops, AV equipment, DVD players, video cameras and any other NRC equipment and hardware are in locked areas of the PDC at the end of every business day. The contractor shall contact the NRC Division of Facilities and Security (DFS) via email to resolve any facility or security issues that may arise. The contractor shall copy the COR on all emails to and from DFS.
- d. The contractor shall continuously maintain an accurate and up-to-date inventory of all PDC equipment and furniture. The contractor shall work with the Contracting Officers Representative (COR) to review and reconcile the NRCs annual equipment inventory records. (Note: The contractor shall not be expected to repair or replace defective or obsolete hardware, software, and furniture, but shall be held accountable for keeping track of all inventories in the training facility, for tracking the movement of inventory from the facility, and for immediately reporting any item that is defective, lost, or missing.)
- e. The contractor shall continuously monitor the daily wear and tear on PDC furniture, equipment, and software in PDC classrooms and shall notify the COR within 1 business day when new furniture, equipment or software is needed, or when existing equipment or furniture needs to be repaired.
The contractor shall prepare an NRC Form 30 for requests for supplies, equipment installation and maintenance, courseware installation, and the disposal of items. The NRC Form 30 shall be prepared within 1 business day of when the need arises and shall be submitted to the COR for signature.
- f. The contractor shall ensure that all hardware and software in the PDC classrooms and PDC computer labs are working properly. The contractor shall report via email all computer hardware, software, and systems malfunctions requiring attention to the NRC Customer Service Center (CSC)
(csc@nrc.gov) and the COR within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the occurrence. The contractor shall monitor the progress on resolution of the problems until resolved and shall notify the COR in writing once the problem has been resolved.
- g. On a daily basis the contractor shall monitor the PDC facility to ensure that it is kept clean and orderly. The contractor shall promptly report any custodial problems to the NRC Administrative Services Center and the COR, and shall monitor the resolution of the problem until it is resolved.
The contractor shall notify the COR in writing once the problem has been resolved. Within the classrooms, the contractor shall wipe down the white boards, table tops, computer keyboards, and monitor screens when they have smudge marks or dirt on them using the supplies available in the PDC for that purpose.
- h. At the end of each week the contractor shall conduct a brief inspection of all PDC spaces to ensure that each classroom contains clean white boards, erasers, white board cleaner, dry markers, flip chart stand and paper.
Page 8 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- i. The contractor shall store all equipment, course materials, and supplies neatly; immediately clear empty boxes from the hallways and either store in the storage closet or place them in the trash, and keep the hallway pamphlet holders full of the appropriate materials at all times, as directed by the COR.
- j. The contractor shall maintain and record in a secured file, all the passwords and logins on all PDC classroom and PDC Computer Lab computers, podium computers, and email checking station computers.
- k. The contractor shall continually monitor and evaluate the operation of the training facility and recommend improvements in processes, procedures, policies, and automation to the COR, as needed.
- l. The contractor shall maintain training support capabilities by learning new NRC computer systems when NRC modifies or updates its software. The contractor shall participate in new implementations when these changes affect training facility and function. This involvement may include participating in the discussions with NRC during planning and preparation, providing insight based on the contractor's day-to-day operation of the PDC and computer training services, performing user testing, and reporting any observations and concerns to the COR. In addition, the contractor shall participate in NRC provided training on the use of the new systems.
- m. The contractor shall maintain accurate and orderly files of training rosters, tests, and other course and student information. All files shall be labelled, easily identifiable, neatly organized, and kept in a locked file cabinet.
- n. The contractor shall provide satisfactory customer service and shall employ strong communication skills.
C.3.2 PDC Training Delivery Support at the PDC and Offsite Locations The contractor shall provide all administrative and logistical support needed to deliver NRC classroom training and distance learning.
- a. On a daily basis the contractor shall receive room reservations requests, schedule classes in the LMS, and keep the room reservation system and wall calendar up-to-date, accurate and free of spelling errors. All room reservation requests shall be processed within 2 business days of receipt.
The contractor shall alert the COR to all potential room scheduling issues, including potential double bookings, within 2 business hours of identifying the issue, and shall work with the COR and other NRC staff, as directed by the COR, to resolve the issue(s).
- b. At least 30 minutes before any class, the contractor shall prepare classrooms and computer labs by ensuring that AV equipment is turned on, furniture is arranged appropriately for the learning activity, needed materials and supplies are in the classroom, the VTC connection is ready and the VTC contractor has been notified and is on-site (if applicable).
- c. The contractor shall greet each instructor when they arrive and provide the class roster, course materials and any other information they need to conduct class. The contractor shall ensure that each visiting instructor has a NRC badge or an escort. The contractor shall show the instructor how to operate all of the AV and computer equipment and software in the classroom or computer lab. While class is in session the contractor shall respond to an instructors requests for assistance within 5 minutes and trouble shoot AV and computer equipment within 5 to 10 minutes.
Page 9 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 This involves either fixing the problem or installing backup equipment in the classroom such that class is able to reconvene within 10 minutes.
- d. On an as needed basis the contractor shall load and unload files, run ghosting software, set up the laptops when a classroom is temporarily turned into a computer lab, and conduct limited trouble shooting of the PDCs classroom computers and laptops in coordination and partnership with the NRC Customer Service Center (CSC@nrc.gov). (Note: All NRC computer systems and software are supported and maintained by the NRC Office of the Chief Information Officer and its contractors. The PDC contractor shall have limited administrative rights to the PDC computer systems.)
- e. On a daily basis the contractor shall print out rosters and place them on the instructors table the first morning of each class. The contractor shall collect signed rosters at the close of business on the last day of class and shall record completions and close out the course offering in the LMS within 3 business days after the class ends.
- f. The contractor shall keep course related information on the HRTD internal Web site accurate and up-to-date. Within 1 business hour of determining that any HRTD website information is incorrect the contractor shall notify the COR via email.
- g. On a weekly basis, the contractor shall review upcoming computer lab courses for the following 2 weeks. The contractor shall ensure the computer labs have the software needed to implement the courses, and verify that the event sponsor or course manager has fulfilled the requirements for reserving classrooms at the PDC. The contractor shall notify the COR via email within 1 business day of determining that the procedures are not being correctly followed.
- h. On an as needed basis, before the beginning of each PDC course, the contractor shall set up any necessary equipment such as cameras, DVD players, TV monitors, and Shure phones. At the conclusion of each course the contractor shall breakdown any equipment that was set up for the course. The breakdown shall take place during the same business day that the class concluded.
If time does not permit breakdown on the same day, then breakdown shall be completed during the first 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the next business day.
- i. The contractor shall ensure that the PDCs inventory of laptops is available when needed to convert a classroom into a temporary computer lab by sending an email to the NRC CSC (csc@nrc.gov) 2 business days prior to the start of the class.
- j. When NRC uses paper-based course evaluations, the contractor shall collect the course evaluations at the end of the course. The contractor shall make one copy of the evaluations, place the copy of the evaluations and the class roster in the course files, and send the original course evaluations via NRC interagency mail to the course manager within 5 business days of completion of the course.
- k. For cancellations, within 1 business day of notification by the course manager, the contractor shall send out email notices to the enrolled employees notifying them that the course has been cancelled.
- l. The contractor shall receive incoming packages of training materials. Within 1 business day of delivery, the contractor shall log the materials in the logbook and store the materials in either the classroom closet where the course will take place, or if space is unavailable, then in the PDC Storage Room. The contractor shall send an email to the appropriate course manager by close of business on the date the materials arrive notifying them that their course materials have arrived.
Page 10 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- m. The contractor shall notify NRC course managers when course documents are less than the amount required for the next course offering. In instances where there is a shortage of course materials, the contractor shall assist NRC course managers in both copying and assembling of course materials. The contractor shall also provide assistance in storing course materials in either the courses assigned classroom closet, if space is available, or in the PDC Storage Room.
- n. The contractor shall schedule requested VTC sessions within one business day of receipt of the request using NRCs online VTC reservation system, and shall update the PDCs calendar of VTC events in Outlook before close of business on the day that the VTC session was scheduled. The contractor shall cancel or reschedule VTC sessions within 2 business hours of receipt of the request.
- o. The contractor shall schedule requested GoTo Meeting sessions within one business day of receipt of the request. Two business days before the event the contractor shall send the participants the access information. On the day of the event the contractor shall work with the requester to ensure that the session begins as scheduled and does not experience any technical problems. The contractor shall troubleshoot the system as needed, and cancel or reschedule existing GoTo Meeting sessions within 2 business hours of receipt of the request.
- p. The contractor shall provide logistical assistance for HRTD classroom courses delivered at NRCs facilities located at NRC Headquarters; Region I, Region II, Region III, Region IV and the NRC Technical Training Center (TTC). Logistical assistance is defined as coordination with the course manager to identify a date, available classroom and faculty, and classroom coordination for the set up at the remote training site. The contractor shall mail all course materials and finalize all classroom arrangements at least 7 business days before the offsite class is scheduled to begin.
- q. The contractor shall provide support and assistance in setting up and conducting virtual training using tools such as, but not limited to, the GoTo Meeting Suite and AdobeConnect.
- r. Throughout the period of performance, the contractor shall provide training support at the PDC and Offsite locations (support provided remotely) including, but not limited to, general IT support with webinars, GoToMeetings, AdobeConnect, VTC, videos and any other IT systems (e.g., VM Ware) to support the training venue.
C.3.3 PDC Student Records and Course Data Maintenance in the LMS The contractor shall accurately and efficiently maintain course and student data records in the LMS and shall perform the actions stated below at the request of the COR or Course Managers.
- a. Create, cancel, and schedule learning events in the LMS within 2 business days of when the request is made.
- b. Register, withdraw, or cancel student enrollments within 2 business days of the request.
- c. On a weekly basis, check the LMS completion data for duplication and accuracy and notify the iLearn Administrator(s) via email of duplicative records within 1 business day of identification.
- d. As requested, complete various LMS support activities such as records management, data review and input, maintenance of the LMS catalogue of classroom and online courses.
- e. As requested by the COR, generate reports from the LMS course data.
- f. Return telephone calls and reply to emails from NRC staff related to questions on courses, student enrollments, and training records in the LMS within one business day of receipt.
Page 11 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- g. Forward technical LMS inquires and technical issues beyond the scope of the PDC to the iLearn Administrator(s) located in HRTD within 1 business day of receipt.
C.3.4 External Training (SF-182) Support The PDC Operations contractor shall support NRC staff in registering employees for external training upon approval and funding of the SF-182, as follows:
- a. Register NRC staff for external training (via the SF-182) with requested training vendor utilizing the documented written process. The documented written process will be provided to the contractor subsequent to award.
- b. Confer with either the External Training Program Manager or the LOPIB Branch Chief for those registration items where there are questions or problems.
- c. Send an email to the External Training Program Manager or designee weekly to provide the status of external training (SF-182) items not started, pending, approved, and completed.
- d. Communicate via email with NRC staff as necessary to obtain any additional information needed to finalize a course registration.
- e. Alert either the External Training Program Manager or the LOPIB Branch Chief via email within 1 business day of identification of any problems or issues, where additional assistance is needed.
- f. Provide recommendations for process improvements, where appropriate, to the External Training Program Manager or the LOPIB Branch Chief.
C.4 Estimated Labor Categories, Key Personnel and Levels of Effort Labor Categories, Requirements and Key Personnel. Personnel working under this task order shall meet the minimum requirements for experience and education, as follows:
Labor Category Position Minimum Requirements Key Personnel*
(yes or no)
Sr. Admin At least 4 years of experience in managing and Yes Support/Team supporting a training facility, conference facility, Leader or similar facility. Must have experience in managing a team or leading a group, and the ability to use appropriate judgment to make decisions independently, elevate items (as appropriate) to the COR, and make recommendations for process improvements.
Preferred experience of at least one year supporting a computer classroom or similar facility by trouble shooting minor computer problems, installing files, and solving technical problems when possible to ensure that all computers are operating properly and available for use.
Page 12 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Analytical ability and experience in running reports using a variety of applications, such as Microsoft Excel and Access, including the ability to run reports from a learning management system (LMS); and at least two years of experience in general office administration.
AV/Desktop At least four years of experience supporting a Yes Operations computer classroom or similar facility by setting up computers, podiums and projectors, providing technical assistance to students or customers, trouble shooting minor computer problems, networking computers, resetting and running ghost software, installing files, and solving technical problems when possible to ensure all computers are operating properly and available for use.
Experience in running programs that support distance learning, which may include, but is not limited to: teleconferencing, GoToMeeting, GoToWebinar, GoToTraining; video; AdobeConnect and VMWare technologies.
Overall familiarity with IT programs that support a training facility or conference facility, including basic knowledge of records management, classroom scheduling, course scheduling and registration. Familiarization with maintaining a records database or learning management system (LMS), and producing reports from an LMS, using applications such as Excel and Access.
ADMIN Support At least two years of experience in general office Yes Operations administration, such as ordering supplies, maintaining equipment inventories, processing facility maintenance requests, managing in-house printing of course materials, ordering of externally produced course materials, and demonstrated experience in customer service.
Experience working in either a training or conference facility is preferred.
Familiarization with data entry, producing reports from an IT System, and applications such as Excel and Access is preferred.
Page 13 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Level-of-Effort (in hours). Estimate the number of hours required for each labor category, including base and option periods.
Base Year Option Option Option Option Total Year 1 Year 2 Year 3 Year 4 Labor Estimated Estimated Estimated Estimated Estimated Category Hours Hours Hours Hours Hours Sr. Admin 2,000 2,000 2,000 2,000 2,000 10,000 Support/Team Leader AV/Desktop 2,000 2,000 2,000 2,000 2,000 10,000 Support ADMIN 2,000 2,000 2,000 2,000 2,000 10,000 Support Operations Grand 30,000 Total:
C.5 Certification and License Requirements The following certifications are preferred, but not required. If individuals do possess them, then the contractor shall ensure that its employees assigned to this Government task order maintain these certifications throughout the term of the task order.
- 1. Project Management Certification (e.g., PMP) is preferred for the Sr. Admin Support / Team Leader position
- 2. Microsoft Office Specialist Certification is preferred for the Admin Support Operations position C.6 Reporting Requirements In addition to meeting all of the operational requirements specified in Section C.4, the contractor shall also prepare and provide the reports indicated below.
C.6.1 Monthly Status Report The contractor shall provide a Monthly Status Report (MSR) on the 5th business day of the following month that consists of a technical progress report and a financial status report. This report will be used by the Government to assess the adequacy of the resources proposed by the contractor to accomplish the work contained in this SOW and provide status of contractor progress in achieving tasks and producing deliverables. The report shall include task order summary information, work completed during the specified period, milestone schedule information, pending issues, problem resolution, travel plans, and staff hour summary.
The MSR shall also include a detailed breakout by week of the following items: number of telephone calls received in the PDC (via main line), number of emails received in the PDC Resource email account, listing of weekly reports completed, closed student rosters, number of GoToMeetings set-up, number of laptops set-up, number of students cancelled, withdrawn, or registered for internal training, and number of external registrations completed.
C.6.2 Monthly Student Completion Report The contractor shall provide a Monthly Student Completion Report to the COR and all Course Managers by 3:00 p.m. on the second Thursday of every month that includes student name and identification number; Page 14 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 course name and identification number, course date, and completion status.
C.6.3 Monthly Student Cancellation Report The contractor shall provide a Monthly Student Cancellation Report to the COR and all Course Managers by 3:00 p.m. on the second Thursday of every month that includes student name and identification number; student office assignment, course name and identification number; course date, and course cancellation date.
C.6.4 Weekly Upcoming Scheduled Training Report The contractor shall provide a Weekly Upcoming Scheduled Training Report to the COR and all Course Managers by 3:00 p.m. every Thursday that includes course name and identification number, course date, course description, course location, and course registration status information including course registration totals and available course seats.
C.6.5 Monthly No-Show Report The contractor shall provide a Monthly No-Show Report to the COR and all Course Managers by 3:00 p.m. on the second Thursday of every month that includes course name and identification number, student name and identification number, course date, student office assignment, status information including no-show or late cancellation, and course cancellation date (if applicable). The contractor shall also provide a copy of this report to OCHCO/HRTD/Professional Development Branch (contact name to be provided subsequent to award).
C.7 List of Deliverables Section # Deliverable Due Date Format Submit to C.7.1 Monthly Status 5th business day of Word COR/CO Report the following document month C.7.2 Monthly Student By 3:00 p.m. on Excel COR/Course Completion the second document Managers Report Thursday of every month C.7.3 Monthly Student By 3:00 p.m. on Excel COR/Course Cancellation the second document Managers Report Thursday of every month C.7.4 Weekly By 3:00 p.m. every Excel COR/Course Upcoming Thursday document Managers Scheduled Training Report C.7.5 Monthly No-Show By 3:00 p.m. on Excel COR/Course Report second Thursday document Managers of every month Acceptability Criteria for Deliverables: Deliverables contain all of the required information.
C.8 Required Materials/Facilities N/A Page 15 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 C.9 Release of Publications Any documents generated by the contractor under this task order shall not be released for publication or dissemination without CO and COR prior written approval.
C.10 Place of Performance The work to be performed under this task order shall primarily be performed at the Professional Development Center (PDC) currently located at 11601 Landsdown Street, N. Bethesda, MD 20852. The current PDC facility is located within the NRCs 3 White Flint North (3WFN) building, on the second floor.
C.11 Recognized Holidays The contractor shall not perform services on the Federal holidays listed below:
New Years Day Labor Day Martin Luther King Jr.s Birthday Columbus Day Presidents Day Veterans Day Memorial Day Thanksgiving Day Independence Day Christmas Day In the event of Government or facility closures, the contractor shall not perform within scope services under the task order at an alternative site. All work performed on behalf of the NRC shall be conducted at an authorized NRC facility during normal work hours.
C.12 Hours of Operation The contractor shall provide required support to the NRC every day the agency is open for work except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings. The contractor shall ensure that the PDC is open and ready for onsite and remote (e.g., distance learning) classes from 8:00 a.m. to 4:15 p.m. every day that the Federal Government is open for business. At least one contractor staff member shall arrive daily at the PDC by 7:00 a.m. to set up classrooms, and turn on AV equipment and classroom computers and podiums. At least one contractor staff member shall remain at the facility until 4:45 p.m. to ensure all classrooms are properly shut down and AV equipment and classrooms computers are turned off. When the Government experiences a delayed opening, the contractor shall arrive at least 30 to 45 minutes before the scheduled opening.
C.13 Contractor Travel N/A C.14 Data Rights N/A C.15 Applicable Publications (Current Editions)
Page 16 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 The contractor shall comply with the following applicable regulations, publications, manuals, and local policies and procedures:
- 1. MD 10.77, Employee Training and Development
- 2. Standard Operating Procedure (SOP) for the PDC C.16 Transition It is anticipated that a 30 calendar day transition period shall be required in order for the contractor to become fully operational. This transition period shall consist of on-site training of contractor personnel (as necessary),
the transfer and disposition of paper-based and electronic documents, and the final hand-off of responsibility for performing the work from the current provider to the contractor. In order to provide sufficient time for contractor personnel to complete the security clearance process, it is anticipated that the start work date and transition period will commence two months after the award date.
Page 17 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION D - Packaging and Marking D.1 NRCD020 BRANDING The Contractor is required to use the statement below in any publications, presentations, articles, products, or materials funded under this contract/order, to the extent practical, in order to provide NRC with recognition for its involvement in and contribution to the project. If the work performed is funded entirely with NRC funds, then the contractor must acknowledge that information in its documentation/presentation.
Work Supported by the U.S. Nuclear Regulatory Commission (NRC), Office of Chief of Human Capital Officer, under Contract/order number GS00F003X/NRC-HQ-84-16-T-0001.
Page 18 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION E - Inspection and Acceptance E.1 NOTICE LISTING CONTRACT CLAUSES INCORPORATED BY REFERENCE The following contract clauses pertinent to this section are hereby incorporated by reference (by Citation Number, Title, and Date) in accordance with the clause at FAR 52.252-2 CLAUSES INCORPORATED BY REFERENCE in Section I of this contract. See FAR 52.252-2 for an internet address (if specified) for electronic access to the full text of a clause.
NUMBER TITLE DATE FEDERAL ACQUISITION REGULATION (48 CFR Chapter 1) 52.246-6 INSPECTION - TIME-AND-MATERIAL AND LABOR-HOUR (MAY 2001)
E.2 NRCE010 INSPECTION AND ACCEPTANCE BY THE NRC (SEP 2013)
Inspection and acceptance of the deliverable items to be furnished hereunder shall be made by the NRC Contracting Officers Representative (COR) at the destination, accordance with FAR 52.247 F.o.b.
Destination.
Contract Deliverables:
- 1. Monthly Status Report
- 2. Monthly Student Completion Report
- 3. Monthly Student Cancellation Report
- 4. Weekly Upcoming Scheduled Training Report
- 5. Monthly No-Show Report Page 19 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION F - Deliveries or Performance F.1 52.252-2 CLAUSES INCORPORATED BY REFERENCE. (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):
http://www.acquisition.gov/far/html/52 248 253.html#wp1120047 52.242-15 STOP-WORK ORDER. (AUG 1989) 52.247-34 F.O.B. DESTINATION (NOV 1991)
F.2 NRCF034 OPTION PERIODS - TASK ORDER/DELIVERY ORDER UNDER A GSA FEDERAL SUPPLY SCHEDULE CONTRACT The Period of Performance (POP) for this requirement may extend beyond the Offeror's current POP on their GSA Schedule. Offerors may submit proposals for the entire POP as long as their current GSA Schedule covers the requested POP, or their GSA Schedule contains GSA's "Evergreen Clause" (Option to Extend the Term of the Contract), which covers the requested POP if/when the option(s) are exercised. Offerors are encouraged to submit accurate/realistic pricing for the requirement's entire POP, even if the proposed GSA Schedule does not include pricing for the applicable option years, etc.
For proposal evaluation purposes, the NRC assumes that applicable Evergreen Clause Option(s) will be exercised and the NRC will apply price analysis, as applicable. It is in the best interest of the Offeror to explain major deviations in escalation, proposed in any Evergreen Clause option years. Resulting GSA task/delivery order option years subject to the Evergreen Clause will be initially priced utilizing the same rates proposed under the last GSA-priced year of the subject GSA Schedule. Upon GSA's exercise of the GSA Schedule option year(s) applicable to the Evergreen Clause, the NRC will modify the awarded task/delivery order to incorporate either the proposed pricing for the option years or the GSA-approved pricing (whichever is lower).
It is incumbent upon the Offeror to provide sufficient documentation (GSA-signed schedule, schedule modifications, etc.) that shows both the effective dates, pricing and terms/conditions of the current GSA Schedule, as well as Evergreen Clause terms/conditions (as applicable). Failure to provide this documentation may result in the Offeror's proposal being found unacceptable.
F.3 NRCF030D PERIOD OF PERFORMANCE ALTERNATE IV The ordering period for this contract shall commence on 09/12/2016 and will expire on 09/11/2021. Any orders issued during this period shall be completed within the time specified in the order, unless otherwise specified herein. (See 52.216 Ordering.) The term of this contract may be extended at the option of the Government for an additional 6 months.
Base Period: 09/12/2016 - 09/11/2017 Option Period(s):
Option Year 1: 09/12/2017 - 09/11/2018 Option Year 2: 09/12/2018 - 09/11/2019 Option Year 3: 09/12/2019 - 09/11/2020 Option Year 4: 09/12/2020 - 09/11/2021 Page 20 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION G - Contract Administration Data G.1 NRCG030 ELECTRONIC PAYMENT (SEP 2014)
The Debt Collection Improvement Act of 1996 requires that all payments except IRS tax refunds be made by Electronic Funds Transfer. Payment shall be made in accordance with FAR 52.232-33, entitled Payment by Electronic Funds-Central Contractor Registration.
To receive payment, the contractor shall prepare invoices in accordance with NRCs Billing Instructions.
Claims shall be submitted on the payees letterhead, invoice, or on the Governments Standard Form 1034, Public Voucher for Purchases and Services Other than Personal, and Standard Form 1035, Public Voucher for Purchases Other than Personal - Continuation Sheet. The preferred method of submitting invoices is electronically to: NRCPayments@nrc.gov.
Page 21 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION H - Special Contract Requirements H.1 2009.570 NRC ORGANIZATIONAL CONFLICTS OF INTEREST.
2009.570-1 SCOPE OF POLICY.
(a) It is the policy of NRC to avoid, eliminate, or neutralize contractor organizational conflicts of interest. The NRC achieves this objective by requiring all prospective contractors to submit information describing relationships, if any, with organizations or persons (including those regulated by the NRC) which may give rise to actual or potential conflicts of interest in the event of contract award.
(b) Contractor conflict of interest determinations cannot be made automatically or routinely. The application of sound judgment on virtually a case-by-case basis is necessary if the policy is to be applied to satisfy the overall public interest. It is not possible to prescribe in advance a specific method or set of criteria which would serve to identify and resolve all of the contractor conflict of interest situations that might arise. However, examples are provided in these regulations to guide application of this policy guidance. The ultimate test is as follows:
Might the contractor, if awarded the contract, be placed in a position where its judgment may be biased, or where it may have an unfair competitive advantage?
(c) The conflict of interest rule contained in this subpart applies to contractors and offerors only. Individuals or firms who have other relationships with the NRC (e.g., parties to a licensing proceeding) are not covered by this regulation. This rule does not apply to the acquisition of consulting services through the personnel appointment process, NRC agreements with other Government agencies, international organizations, or state, local, or foreign Governments. Separate procedures for avoiding conflicts of interest will be employed in these agreements, as appropriate.
2009.570-2 DEFINITIONS.
Affiliates means business concerns which are affiliates of each other when either directly or indirectly one concern or individual controls or has the power to control another, or when a third party controls or has the power to control both.
Contract means any contractual agreement or other arrangement with the NRC except as provided in 2009.570-1(c).
Contractor means any person, firm, unincorporated association, joint venture, co-sponsor, partnership, corporation, affiliates thereof, or their successors in interest, including their chief executives, directors, key personnel (identified in the contract), proposed consultants or subcontractors, which are a party to a contract with the NRC.
Evaluation activities means any effort involving the appraisal of a technology, process, product, or policy.
Offeror or prospective contractor means any person, firm, unincorporated association, joint venture, co-sponsor, partnership, corporation, or their affiliates or successors in interest, including their chief executives, directors, key personnel, proposed consultants, or subcontractors, submitting a bid or proposal, solicited or unsolicited, to the NRC to obtain a contract.
Organizational conflicts of interest means that a relationship exists whereby a contractor or prospective contractor has present or planned interests related to the work to be performed under an NRC contract which:
(1) May diminish its capacity to give impartial, technically sound, objective assistance and advice, or may Page 22 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 otherwise result in a biased work product; or (2) May result in its being given an unfair competitive advantage.
Potential conflict of interest means that a factual situation exists that suggests that an actual conflict of interest may arise from award of a proposed contract. The term potential conflict of interest is used to signify those situations that (1) Merit investigation before contract award to ascertain whether award would give rise to an actual conflict; or (2) Must be reported to the contracting officer for investigation if they arise during contract performance.
Research means any scientific or technical work involving theoretical analysis, exploration, or experimentation.
Subcontractor means any subcontractor of any tier who performs work under a contract with the NRC except subcontracts for supplies and subcontracts in amounts not exceeding $10,000.
Technical consulting and management support services means internal assistance to a component of the NRC in the formulation or administration of its programs, projects, or policies which normally require that the contractor be given access to proprietary information or to information that has not been made available to the public. These services typically include assistance in the preparation of program plans, preliminary designs, specifications, or statements of work.
2009.570-3 CRITERIA FOR RECOGNIZING CONTRACTOR ORGANIZATIONAL CONFLICTS OF INTEREST.
(a) General.
(1) Two questions will be asked in determining whether actual or potential organizational conflicts of interest exist:
(i) Are there conflicting roles which might bias an offeror's or contractor's judgment in relation to its work for the NRC?
(ii) May the offeror or contractor be given an unfair competitive advantage based on the performance of the contract?
(2) NRC's ultimate determination that organizational conflicts of interest exist will be made in light of common sense and good business judgment based upon the relevant facts. While it is difficult to identify and to prescribe in advance a specific method for avoiding all of the various situations or relationships that might involve potential organizational conflicts of interest, NRC personnel will pay particular attention to proposed contractual requirements that call for the rendering of advice, consultation or evaluation activities, or similar activities that directly lay the groundwork for the NRC's decisions on regulatory activities, future procurements, and research programs. Any work performed at an applicant or licensee site will also be closely scrutinized by the NRC staff.
(b) Situations or relationships. The following situations or relationships may give rise to organizational conflicts of interest:
(1) The offeror or contractor shall disclose information that may give rise to organizational conflicts of interest under the following circumstances. The information may include the scope of work or specification for the requirement being performed, the period of performance, and the name and telephone number for a point of Page 23 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 contact at the organization knowledgeable about the commercial contract.
(i) Where the offeror or contractor provides advice and recommendations to the NRC in the same technical area where it is also providing consulting assistance to any organization regulated by the NRC.
(ii) Where the offeror or contractor provides advice to the NRC on the same or similar matter on which it is also providing assistance to any organization regulated by the NRC.
(iii) Where the offeror or contractor evaluates its own products or services, or has been substantially involved in the development or marketing of the products or services of another entity.
(iv) Where the award of a contract would result in placing the offeror or contractor in a conflicting role in which its judgment may be biased in relation to its work for the NRC, or would result in an unfair competitive advantage for the offeror or contractor.
(v) Where the offeror or contractor solicits or performs work at an applicant or licensee site while performing work in the same technical area for the NRC at the same site.
(2) The contracting officer may request specific information from an offeror or contractor or may require special contract clauses such as provided in 2009.570-5(b) in the following circumstances:
(i) Where the offeror or contractor prepares specifications that are to be used in competitive procurements of products or services covered by the specifications.
(ii) Where the offeror or contractor prepares plans for specific approaches or methodologies that are to be incorporated into competitive procurements using the approaches or methodologies.
(iii) Where the offeror or contractor is granted access to information not available to the public concerning NRC plans, policies, or programs that could form the basis for a later procurement action.
(iv) Where the offeror or contractor is granted access to proprietary information of its competitors.
(v) Where the award of a contract might result in placing the offeror or contractor in a conflicting role in which its judgment may be biased in relation to its work for the NRC or might result in an unfair competitive advantage for the offeror or contractor.
(c) Policy application guidance. The following examples are illustrative only and are not intended to identify and resolve all contractor organizational conflict of interest situations.
(1)(i) Example. The ABC Corp., in response to a Request For Proposal (RFP), proposes to undertake certain analyses of a reactor component as called for in the RFP. The ABC Corp. is one of several companies considered to be technically well qualified. In response to the inquiry in the RFP, the ABC Corp. advises that it is currently performing similar analyses for the reactor manufacturer.
(ii) Guidance. An NRC contract for that particular work normally would not be awarded to the ABC Corp.
because the company would be placed in a position in which its judgment could be biased in relationship to its work for the NRC. Because there are other well-qualified companies available, there would be no reason for considering a waiver of the policy.
(2)(i) Example. The ABC Corp., in response to an RFP, proposes to perform certain analyses of a reactor component that is unique to one type of advanced reactor. As is the case with other technically qualified companies responding to the RFP, the ABC Corp. is performing various projects for several different utility Page 24 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 clients. None of the ABC Corp. projects have any relationship to the work called for in the RFP. Based on the NRC evaluation, the ABC Corp. is considered to be the best qualified company to perform the work outlined in the RFP.
(ii) Guidance. An NRC contract normally could be awarded to the ABC Corp. because no conflict of interest exists which could motivate bias with respect to the work. An appropriate clause would be included in the contract to preclude the ABC Corp. from subsequently contracting for work with the private sector that could create a conflict during the performance of the NRC contract. For example, ABC Corp. would be precluded from the performance of similar work for the company developing the advanced reactor mentioned in the example.
(3)(i) Example. The ABC Corp., in response to a competitive RFP, submits a proposal to assist the NRC in revising NRC's guidance documents on the respiratory protection requirements of 10 CFR Part 20. ABC Corp.
is the only firm determined to be technically acceptable. ABC Corp. has performed substantial work for regulated utilities in the past and is expected to continue similar efforts in the future. The work has and will cover the writing, implementation, and administration of compliance respiratory protection programs for nuclear power plants.
(ii) Guidance. This situation would place the firm in a role where its judgment could be biased in relationship to its work for the NRC. Because the nature of the required work is vitally important in terms of the NRC's responsibilities and no reasonable alternative exists, a waiver of the policy, in accordance with 2009.570-9 may be warranted. Any waiver must be fully documented in accordance with the waiver provisions of this policy with particular attention to the establishment of protective mechanisms to guard against bias.
(4)(i) Example. The ABC Corp. submits a proposal for a new system to evaluate a specific reactor component's performance for the purpose of developing standards that are important to the NRC program. The ABC Corp.
has advised the NRC that it intends to sell the new system to industry once its practicability has been demonstrated. Other companies in this business are using older systems for evaluation of the specific reactor component.
(ii) Guidance. A contract could be awarded to the ABC Corp. if the contract stipulates that no information produced under the contract will be used in the contractor's private activities unless this information has been reported to the NRC. Data on how the reactor component performs, which is reported to the NRC by contractors, will normally be disseminated by the NRC to others to preclude an unfair competitive advantage.
When the NRC furnishes information about the reactor component to the contractor for the performance of contracted work, the information may not be used in the contractor's private activities unless the information is generally available to others. Further, the contract will stipulate that the contractor will inform the NRC contracting officer of all situations in which the information, developed about the performance of the reactor component under the contract, is proposed to be used.
(5)(i) Example. The ABC Corp., in response to a RFP, proposes to assemble a map showing certain seismological features of the Appalachian fold belt. In accordance with the representation in the RFP and 2009.570-3(b)(1)(i), ABC Corp. informs the NRC that it is presently doing seismological studies for several utilities in the eastern United States, but none of the sites are within the geographic area contemplated by the NRC study.
(ii) Guidance. The contracting officer would normally conclude that award of a contract would not place ABC Corp. in a conflicting role where its judgment might be biased. Section 2052.209-72(c) Work for Others, would preclude ABC Corp. from accepting work which could create a conflict of interest during the term of the NRC contract.
(6)(i) Example. AD Division of ABC Corp., in response to a RFP, submits a proposal to assist the NRC in the Page 25 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 safety and environmental review of applications for licenses for the construction, operation, and decommissioning of fuel cycle facilities. ABC Corp. is divided into two separate and distinct divisions, AD and BC. The BC Division performs the same or similar services for industry. The BC Division is currently providing the same or similar services required under the NRC's contract for an applicant or licensee.
(ii) Guidance. An NRC contract for that particular work would not be awarded to the ABC Corp. The AD Division could be placed in a position to pass judgment on work performed by the BC Division, which could bias its work for NRC. Further, the Conflict of Interest provisions apply to ABC Corp. and not to separate or distinct divisions within the company. If no reasonable alternative exists, a waiver of the policy could be sought in accordance with 2009.570-9.
(7)(i) Example. The ABC Corp. completes an analysis for NRC of steam generator tube leaks at one of a utility's six sites. Three months later, ABC Corp. is asked by this utility to perform the same analysis at another of its sites.
(ii) Guidance. Section 2052.290-72(c)(3) would prohibit the contractor from beginning this work for the utility until one year after completion of the NRC work at the first site.
(8)(i) Example. ABC Corp. is assisting NRC in a major on-site analysis of a utility's redesign of the common areas between its twin reactors. The contract is for two years with an estimated value of $5 million. Near the completion of the NRC work, ABC Corp. requests authority to solicit for a $100K contract with the same utility to transport spent fuel to a disposal site. ABC Corp. is performing no other work for the utility.
(ii) Guidance. The Contracting Officer would allow the contractor to proceed with the solicitation because it is not in the same technical area as the NRC work; and the potential for technical bias by the contractor because of financial ties to the utility is slight due to the relative value of the two contracts.
(9)(i) Example. The ABC Corp. is constructing a turbine building and installing new turbines at a reactor site.
The contract with the utility is for five years and has a total value of $100 million. ABC Corp. has responded to an NRC Request For Proposal requiring the contractor to participate in a major team inspection unrelated to the turbine work at the same site. The estimated value of the contract is $75K.
(ii) Guidance. An NRC contract would not normally be awarded to ABC Corp. because these factors create the potential for financial loyalty to the utility that may bias the technical judgment of the contractor.
(d) Other considerations.
(1) The fact that the NRC can identify and later avoid, eliminate, or neutralize any potential organizational conflicts arising from the performance of a contract is not relevant to a determination of the existence of conflicts prior to the award of a contract.
(2) It is not relevant that the contractor has the professional reputation of being able to resist temptations which arise from organizational conflicts of interest, or that a follow-on procurement is not involved, or that a contract is awarded on a competitive or a sole source basis.
2009.570-4 REPRESENTATION.
(a) The following procedures are designed to assist the NRC contracting officer in determining whether situations or relationships exist which may constitute organizational conflicts of interest with respect to a particular offeror or contractor. The procedures apply to small purchases meeting the criteria stated in the following paragraph (b) of this section.
Page 26 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (b) The organizational conflicts of interest representation provision at 2052.209-71 must be included in solicitations and contracts resulting from unsolicited proposals. The contracting officer must also include this provision for task orders and contract modifications for new work for:
(1) Evaluation services or activities; (2) Technical consulting and management support services; (3) Research; and (4) Other contractual situations where special organizational conflicts of interest provisions are noted in the solicitation and would be included in the resulting contract. This representation requirement also applies to all modifications for additional effort under the contract except those issued under the "Changes" clause. Where, however, a statement of the type required by the organizational conflicts of interest representation provisions has previously been submitted with regard to the contract being modified, only an updating of the statement is required.
(c) The offeror may, because of actual or potential organizational conflicts of interest, propose to exclude specific kinds of work contained in a RFP unless the RFP specifically prohibits the exclusion. Any such proposed exclusion by an offeror will be considered by the NRC in the evaluation of proposals. If the NRC considers the proposed excluded work to be an essential or integral part of the required work and its exclusion would be to the detriment of the competitive posture of the other offerors, the NRC shall reject the proposal as unacceptable.
(d) The offeror's failure to execute the representation required by paragraph (b) of this section with respect to an invitation for bids is considered to be a minor informality. The offeror will be permitted to correct the omission.
2009.570-5 CONTRACT CLAUSES.
(a) General contract clause. All contracts and simplified acquisitions of the types set forth in 2009.570-4(b) must include the clause entitled, "Contractor Organizational Conflicts of Interest," set forth in 2052.209-72.
(b) Other special contract clauses. If it is determined from the nature of the proposed contract that an organizational conflict of interest exists, the contracting officer may determine that the conflict can be avoided, or, after obtaining a waiver in accordance with 2009.570-9, neutralized through the use of an appropriate special contract clause. If appropriate, the offeror may negotiate the terms and conditions of these clauses, including the extent and time period of any restriction. These clauses include but are not limited to:
(1) Hardware exclusion clauses which prohibit the acceptance of production contracts following a related non-production contract previously performed by the contractor; (2) Software exclusion clauses; (3) Clauses which require the contractor (and certain of its key personnel) to avoid certain organizational conflicts of interest; and (4) Clauses which provide for protection of confidential data and guard against its unauthorized use.
Page 27 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 2009.570-6 EVALUATION, FINDINGS, AND CONTRACT AWARD.
The contracting officer shall evaluate all relevant facts submitted by an offeror and other relevant information.
After evaluating this information against the criteria of 2009.570-3, the contracting officer shall make a finding of whether organizational conflicts of interest exist with respect to a particular offeror. If it has been determined that real or potential conflicts of interest exist, the contracting officer shall:
(a) Disqualify the offeror from award; (b) Avoid or eliminate such conflicts by appropriate measures; or (c) Award the contract under the waiver provision of 2009.570-9.
2009.570-7 CONFLICTS IDENTIFIED AFTER AWARD.
If potential organizational conflicts of interest are identified after award with respect to a particular contractor and the contracting officer determines that conflicts do exist and that it would not be in the best interest of the Government to terminate the contract, as provided in the clauses required by 2009.570-5, the contracting officer shall take every reasonable action to avoid, eliminate, or, after obtaining a waiver in accordance with 2009.570-9, neutralize the effects of the identified conflict.
2009.570-8 SUBCONTRACTS.
The contracting officer shall require offerors and contractors to submit a representation statement from all subcontractors (other than a supply subcontractor) and consultants performing services in excess of $10,000 in accordance with 2009.570-4(b). The contracting officer shall require the contractor to include contract clauses in accordance with 2009.570-5 in consultant agreements or subcontracts involving performance of work under a prime contract.
2009.570-9 WAIVER.
(a) The contracting officer determines the need to seek a waiver for specific contract awards with the advice and concurrence of the program office director and legal counsel. Upon the recommendation of the Senior Procurement Executive, and after consultation with legal counsel, the Executive Director for Operations may waive the policy in specific cases if he determines that it is in the best interest of the United States to do so.
(b) Waiver action is strictly limited to those situations in which:
(1) The work to be performed under contract is vital to the NRC program; (2) The work cannot be satisfactorily performed except by a contractor whose interests give rise to a question of conflict of interest.
(3) Contractual and/or technical review and surveillance methods can be employed by the NRC to neutralize the conflict.
(c) The justification and approval documents for any waivers must be placed in the NRC Public Document Room.
2009.570-10 REMEDIES.
In addition to other remedies permitted by law or contract for a breach of the restrictions in this subpart or for Page 28 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 any intentional misrepresentation or intentional nondisclosure of any relevant interest required to be provided for this section, the NRC may debar the contractor from subsequent NRC contracts.
H.2 2052.204-70 SECURITY. (OCT 1999)
(a) Security/Classification Requirements Form. The attached NRC Form 187 (See List of Attachments) furnishes the basis for providing security and classification requirements to prime contractors, subcontractors, or others (e.g., bidders) who have or may have an NRC contractual relationship that requires access to classified information or matter, access on a continuing basis (in excess of 90 or more days) to NRC Headquarters controlled buildings, or otherwise requires NRC photo identification or card-key badges.
(b) It is the contractor's duty to safeguard National Security Information, Restricted Data, and Formerly Restricted Data. The contractor shall, in accordance with the Commission's security regulations and requirements, be responsible for safeguarding National Security Information, Restricted Data, and Formerly Restricted Data, and for protecting against sabotage, espionage, loss, and theft, the classified documents and material in the contractor's possession in connection with the performance of work under this contract. Except as otherwise expressly provided in this contract, the contractor shall transmit to the Commission any classified matter in the possession of the contractor or any person under the contractor's control in connection with performance of this contract upon completion or termination of this contract.
(1) The contractor shall complete a certificate of possession to be furnished to the Commission specifying the classified matter to be retained if the retention is:
(i) Required after the completion or termination of the contract; and (ii) Approved by the contracting officer.
(2) The certification must identify the items and types or categories of matter retained, the conditions governing the retention of the matter and their period of retention, if known. If the retention is approved by the contracting officer, the security provisions of the contract continue to be applicable to the matter retained.
(c) In connection with the performance of the work under this contract, the contractor may be furnished, or may develop or acquire, proprietary data (trade secrets) or confidential or privileged technical, business, or financial information, including Commission plans, policies, reports, financial plans, internal data protected by the Privacy Act of 1974 (Pub. L.93-579), or other information which has not been released to the public or has been determined by the Commission to be otherwise exempt from disclosure to the public. The contractor agrees to hold the information in confidence and not to directly or indirectly duplicate, disseminate, or disclose the information, in whole or in part, to any other person or organization except as necessary to perform the work under this contract. The contractor agrees to return the information to the Commission or otherwise dispose of it at the direction of the contracting officer. Failure to comply with this clause is grounds for termination of this contract.
(d) Regulations. The contractor agrees to conform to all security regulations and requirements of the Commission which are subject to change as directed by the NRC Division of Facilities and Security and the Contracting Officer. These changes will be under the authority of the FAR Changes clause referenced in Section I of this document.
(e) Definition of National Security Information. As used in this clause, the term National Security Information means information that has been determined pursuant to Executive Order 12958 or any predecessor order to require protection against unauthorized disclosure and that is so designated.
Page 29 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (f) Definition of Restricted Data. As used in this clause, the term Restricted Data means all data concerning design, manufacture, or utilization of atomic weapons; the production of special nuclear material; or the use of special nuclear material in the production of energy, but does not include data declassified or removed from the Restricted Data category under to Section 142 of the Atomic Energy Act of 1954, as amended.
(g) Definition of Formerly Restricted Data. As used in this clause the term Formerly Restricted Data means all data removed from the Restricted Data category under Section 142-d of the Atomic Energy Act of 1954, as amended.
(h) Security clearance personnel. The contractor may not permit any individual to have access to Restricted Data, Formerly Restricted Data, or other classified information, except in accordance with the Atomic Energy Act of 1954, as amended, and the Commission's regulations or requirements applicable to the particular type or category of classified information to which access is required. The contractor shall also execute a Standard Form 312, Classified Information Nondisclosure Agreement, when access to classified information is required.
(i) Criminal liabilities. Disclosure of National Security Information, Restricted Data, and Formerly Restricted Data relating to the work or services ordered hereunder to any person not entitled to receive it, or failure to safeguard any Restricted Data, Formerly Restricted Data, or any other classified matter that may come to the contractor or any person under the contractor's control in connection with work under this contract, may subject the contractor, its agents, employees, or subcontractors to criminal liability under the laws of the United States.
(See the Atomic Energy Act of 1954, as amended, 42 U.S.C. 2011 et seq.; 18 U.S.C. 793 and 794; and Executive Order 12958.)
(j) Subcontracts and purchase orders. Except as otherwise authorized, in writing, by the contracting officer, the contractor shall insert provisions similar to the foregoing in all subcontracts and purchase orders under this contract.
(k) In performing contract work, the contractor shall classify all documents, material, and equipment originated or generated by the contractor in accordance with guidance issued by the Commission. Every subcontract and purchase order issued under the contract that involves originating or generating classified documents, material, and equipment must provide that the subcontractor or supplier assign the proper classification to all documents, material, and equipment in accordance with guidance furnished by the contractor.
H.3 2052.204-71 SITE ACCESS BADGE REQUIREMENTS. (JAN 1993)
During the life of this contract, the rights of ingress and egress for contractor personnel must be made available as required. In this regard, all contractor personnel whose duties under this contract require their presence on-site shall be clearly identifiable by a distinctive badge furnished by the Government. The Project Officer shall assist the contractor in obtaining the badges for contractor personnel. It is the sole responsibility of the contractor to ensure that each employee has proper identification at all times. All prescribed identification must be immediately delivered to the Security Office for cancellation or disposition upon the termination of employment of any contractor personnel. Contractor personnel shall have this identification in their possession during on-site performance under this contract. It is the contractor's duty to assure that contractor personnel enter only those work areas necessary for performance of contract work and to assure the safeguarding of any Government records or data that contractor personnel may come into contact with.
H.4 2052.209-70 CURRENT/FORMER AGENCY EMPLOYEE INVOLVEMENT. (OCT 1999)
(a) The following representation is required by the NRC Acquisition Regulation 2009.105-70(b). It is not NRC policy to encourage offerors and contractors to propose current/former agency employees to perform work Page 30 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 under NRC contracts and as set forth in the above cited provision, the use of such employees may, under certain conditions, adversely affect NRC's consideration of non-competitive proposals and task orders.
(b) There [ ] are [ ] are no current/former NRC employees (including special Government employees performing services as experts, advisors, consultants, or members of advisory committees) who have been or will be involved, directly or indirectly, in developing the offer, or in negotiating on behalf of the offeror, or in managing, administering, or performing any contract, consultant agreement, or subcontract resulting from this offer. For each individual so identified, the Technical and Management proposal must contain, as a separate attachment, the name of the individual, the individual's title while employed by the NRC, the date individual left NRC, and a brief description of the individual's role under this proposal.
H.5 2052.209-72 CONTRACTOR ORGANIZATIONAL CONFLICTS OF INTEREST. (JAN 1993)
(a) Purpose. The primary purpose of this clause is to aid in ensuring that the contractor:
(1) Is not placed in a conflicting role because of current or planned interests (financial, contractual, organizational, or otherwise) which relate to the work under this contract; and (2) Does not obtain an unfair competitive advantage over other parties by virtue of its performance of this contract.
(b) Scope. The restrictions described apply to performance or participation by the contractor, as defined in 48 CFR 2009.570-2 in the activities covered by this clause.
(c) Work for others.
(1) Notwithstanding any other provision of this contract, during the term of this contract, the contractor agrees to forego entering into consulting or other contractual arrangements with any firm or organization the result of which may give rise to a conflict of interest with respect to the work being performed under this contract. The contractor shall ensure that all employees under this contract abide by the provision of this clause. If the contractor has reason to believe, with respect to itself or any employee, that any proposed consultant or other contractual arrangement with any firm or organization may involve a potential conflict of interest, the contractor shall obtain the written approval of the contracting officer before the execution of such contractual arrangement.
(2) The contractor may not represent, assist, or otherwise support an NRC licensee or applicant undergoing an NRC audit, inspection, or review where the activities that are the subject of the audit, inspection, or review are the same as or substantially similar to the services within the scope of this contract (or task order as appropriate) except where the NRC licensee or applicant requires the contractor's support to explain or defend the contractor's prior work for the utility or other entity which NRC questions.
(3) When the contractor performs work for the NRC under this contract at any NRC licensee or applicant site, the contractor shall neither solicit nor perform work in the same or similar technical area for that licensee or applicant organization for a period commencing with the award of the task order or beginning of work on the site (if not a task order contract) and ending one year after completion of all work under the associated task order, or last time at the site (if not a task order contract).
(4) When the contractor performs work for the NRC under this contract at any NRC licensee or applicant site, (i) The contractor may not solicit work at that site for that licensee or applicant during the period of performance of the task order or the contract, as appropriate.
Page 31 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (ii) The contractor may not perform work at that site for that licensee or applicant during the period of performance of the task order or the contract, as appropriate, and for one year thereafter.
(iii) Notwithstanding the foregoing, the contracting officer may authorize the contractor to solicit or perform this type of work (except work in the same or similar technical area) if the contracting officer determines that the situation will not pose a potential for technical bias or unfair competitive advantage.
(d) Disclosure after award.
(1) The contractor warrants that to the best of its knowledge and belief, and except as otherwise set forth in this contract, that it does not have any organizational conflicts of interest as defined in 48 CFR 2009.570-2.
(2) The contractor agrees that if, after award, it discovers organizational conflicts of interest with respect to this contract, it shall make an immediate and full disclosure in writing to the contracting officer. This statement must include a description of the action which the contractor has taken or proposes to take to avoid or mitigate such conflicts. The NRC may, however, terminate the contract if termination is in the best interest of the Government.
(3) It is recognized that the scope of work of a task-order-type contract necessarily encompasses a broad spectrum of activities. Consequently, if this is a task-order-type contract, the contractor agrees that it will disclose all proposed new work involving NRC licensees or applicants which comes within the scope of work of the underlying contract. Further, if this contract involves work at a licensee or applicant site, the contractor agrees to exercise diligence to discover and disclose any new work at that licensee or applicant site. This disclosure must be made before the submission of a bid or proposal to the utility or other regulated entity and must be received by the NRC at least 15 days before the proposed award date in any event, unless a written justification demonstrating urgency and due diligence to discover and disclose is provided by the contractor and approved by the contracting officer. The disclosure must include the statement of work, the dollar value of the proposed contract, and any other documents that are needed to fully describe the proposed work for the regulated utility or other regulated entity. NRC may deny approval of the disclosed work only when the NRC has issued a task order which includes the technical area and, if site-specific, the site, or has plans to issue a task order which includes the technical area and, if site-specific, the site, or when the work violates paragraphs (c)(2), (c)(3) or (c)(4) of this section.
(e) Access to and use of information.
(1) If, in the performance of this contract, the contractor obtains access to information, such as NRC plans, policies, reports, studies, financial plans, internal data protected by the Privacy Act of 1974 (5 U.S.C. Section 552a (1988)), or the Freedom of Information Act (5 U.S.C. Section 552 (1986)), the contractor agrees not to:
(i) Use this information for any private purpose until the information has been released to the public; (ii) Compete for work for the Commission based on the information for a period of six months after either the completion of this contract or the release of the information to the public, whichever is first; (iii) Submit an unsolicited proposal to the Government based on the information until one year after the release of the information to the public; or (iv) Release the information without prior written approval by the contracting officer unless the information has previously been released to the public by the NRC.
(2) In addition, the contractor agrees that, to the extent it receives or is given access to proprietary data, data Page 32 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 protected by the Privacy Act of 1974 (5 U.S.C. Section 552a (1988)), or the Freedom of Information Act (5 U.S.C. Section 552 (1986)), or other confidential or privileged technical, business, or financial information under this contract, the contractor shall treat the information in accordance with restrictions placed on use of the information.
(3) Subject to patent and security provisions of this contract, the contractor shall have the right to use technical data it produces under this contract for private purposes provided that all requirements of this contract have been met.
(f) Subcontracts. Except as provided in 48 CFR 2009.570-2, the contractor shall include this clause, including this paragraph, in subcontracts of any tier. The terms contract, contractor, and contracting officer, must be appropriately modified to preserve the Government's rights.
(g) Remedies. For breach of any of the above restrictions, or for intentional nondisclosure or misrepresentation of any relevant interest required to be disclosed concerning this contract or for such erroneous representations that necessarily imply bad faith, the Government may terminate the contract for default, disqualify the contractor from subsequent contractual efforts, and pursue other remedies permitted by law or this contract.
(h) Waiver. A request for waiver under this clause must be directed in writing to the contracting officer in accordance with the procedures outlined in 48 CFR 2009.570-9.
(i) Follow-on effort. The contractor shall be ineligible to participate in NRC contracts, subcontracts, or proposals therefor (solicited or unsolicited) which stem directly from the contractor's performance of work under this contract. Furthermore, unless so directed in writing by the contracting officer, the contractor may not perform any technical consulting or management support services work or evaluation activities under this contract on any of its products or services or the products or services of another firm if the contractor has been substantially involved in the development or marketing of the products or services.
(1) If the contractor under this contract, prepares a complete or essentially complete statement of work or specifications, the contractor is not eligible to perform or participate in the initial contractual effort which is based on the statement of work or specifications. The contractor may not incorporate its products or services in the statement of work or specifications unless so directed in writing by the contracting officer, in which case the restrictions in this paragraph do not apply.
(2) Nothing in this paragraph precludes the contractor from offering or selling its standard commercial items to the Government.
H.6 2052.215-70 KEY PERSONNEL. (JAN 1993)
(a) The following individuals are considered to be essential to the successful performance of the work hereunder:
Sr. Admin Support/ Team Leader AV/Desktop Support Admin Support Operations The contractor agrees that personnel may not be removed from the contract work or replaced without compliance with paragraphs (b) and (c) of this section.
Page 33 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (3) In any way causes an increase or decrease in the total estimated contract cost, the fixed fee, if any, or the time required for contract performance.
(4) Changes any of the expressed terms, conditions, or specifications of the contract.
(5) Terminates the contract, settles any claim or dispute arising under the contract, or issues any unilateral directive whatever.
(d) All technical directions must be issued in writing by the project officer or must be confirmed by the project officer in writing within ten (10) working days after verbal issuance. A copy of the written direction must be furnished to the contracting officer. A copy of NRC Form 445, Request for Approval of Official Foreign Travel, which has received final approval from the NRC must be furnished to the contracting officer.
(e) The contractor shall proceed promptly with the performance of technical directions duly issued by the project officer in the manner prescribed by this clause and within the project officer's authority under the provisions of this clause.
(f) If, in the opinion of the contractor, any instruction or direction issued by the project officer is within one of the categories defined in paragraph (c) of this section, the contractor may not proceed but shall notify the contracting officer in writing within five (5) working days after the receipt of any instruction or direction and shall request that contracting officer to modify the contract accordingly. Upon receiving the notification from the contractor, the contracting officer shall issue an appropriate contract modification or advise the contractor in writing that, in the contracting officer's opinion, the technical direction is within the scope of this article and does not constitute a change under the "Changes" clause.
(g) Any unauthorized commitment or direction issued by the project officer may result in an unnecessary delay in the contractor's performance and may even result in the contractor expending funds for unallowable costs under the contract.
(h) A failure of the parties to agree upon the nature of the instruction or direction or upon the contract action to be taken with respect to the instruction or direction is subject to 52.233 Disputes.
(i) In addition to providing technical direction as defined in paragraph (b) of the section, the project officer shall:
(1) Monitor the contractor's technical progress, including surveillance and assessment of performance, and recommend to the contracting officer changes in requirements.
(2) Assist the contractor in the resolution of technical problems encountered during performance.
(3) Review all costs requested for reimbursement by the contractor and submit to the contracting officer recommendations for approval, disapproval, or suspension of payment for supplies and services required under this contract.
H.8 AWARD NOTIFICATION AND COMMITMENT OF PUBLIC FUNDS (OCT 1999)
(a) All offerors will be notified of their exclusion from the competitive range in accordance with FAR 15.503(a)(1). Under the requirements of FAR 15.503(a)(2), preliminary notification will be provided before award for small business set-aside procurements on negotiated procurements. The contracting officer shall provide written postaward notice to each unsuccessful offeror in accordance with FAR 15.503(b).
Page 35 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (b) The contracting officer is the only individual who can legally commit the NRC to the expenditure of public funds in connection with this procurement. This means that, unless provided in a contract document or specifically authorized by the contracting officer, NRC technical personnel may not issue contract modifications, give informal contractual commitments, or otherwise bind, commit, or obligate the NRC contractually. Informal contractual commitments include:
(1) Encouraging a potential contractor to incur costs before receiving a contract; (2) Requesting or requiring a contractor to make changes under a contract without formal contract modifications; (3) Encouraging a contractor to incur costs under a cost-reimbursable contract in excess of those costs contractually allowable; and (4) Committing the Government to a course of action with regard to a potential contract, contract change, claim, or dispute.
H.9 2052.215-74 DISPOSITION OF PROPOSALS (JAN 1993)
After award of the contract, one copy of each unsuccessful proposal is retained by the NRC's Division of Contracts and Property Management in accordance with the General Records Schedule 3(5)(b). Unless return of the additional copies of the proposals is requested by the offeror upon submission of the proposals, all other copies will be destroyed. This request should appear in a cover letter accompanying the proposal.
H.10 2052.222-70 NONDISCRIMINATION BECAUSE OF AGE (JAN 1993)
It is the policy of the Executive Branch of the Government that:
(a) Contractors and subcontractors engaged in the performance of Federal contracts may not, in connection with the employment, advancement, or discharge of employees or in connection with the terms, conditions, or privileges of their employment, discriminate against persons because of their age except upon the basis of a bona fide occupational qualification, retirement plan, or statutory requirement; and (b) That contractors and subcontractors, or persons acting on their behalf, may not specify, in solicitations or advertisements for employees to work on Government contracts, a maximum age limit for employment unless the specified maximum age limit is based upon a bona fide occupational qualification, retirement plan, or statutory requirement.
H.11 NRCH490 AWARD NOTIFICATION AND COMMITMENT OF PUBLIC FUNDS (a) All offerors will receive preaward and postaward notices in accordance with FAR 15.503.
(b) It is also brought to your attention that the contracting officer is the only individual who can legally obligate funds or commit the NRC to the expenditure of public funds in connection with this procurement. This means that unless provided in a contract document or specifically authorized by the contracting officer, NRC technical personnel may not issue contract modifications, give formal Page 36 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 contractual commitments, or otherwise bind, commit, or obligate the NRC contractually. Informal unauthorized commitments, which do not obligate the NRC and do not entitle the contractor to payment, may include:
(1) Encouraging a potential contractor to incur costs prior to receiving a contract; (2) Requesting or requiring a contractor to make changes under a contract without formal contract modifications; (3) Encouraging a contractor to incur costs under a cost-reimbursable contract in excess of those costs contractually allowable; and (4) Committing the Government to a course of action with regard to a potential contract, contract change, claim, or dispute.
H.12 NRCH480 USE OF AUTOMATED CLEARING HOUSE (ACH) ELECTRONIC PAYMENT/REMITTANCE ADDRESS The Debt Collection Improvement Act of 1996 requires that all Federal payments except IRS tax refunds be made by Electronic Funds Transfer. lt is the policy of the Nuclear Regulatory Commission to pay government vendors by the Automated Clearing House (ACH) electronic funds transfer payment system. Item 15C of the Standard Form 33 may be disregarded.
H.13 NRCH470 GREEN PURCHASING (SEP 2015)
(a) In furtherance of the sustainable acquisition goals of Executive Order (EO) 13693, "Planning for Federal Sustainability in the Next Decade," products and services provided under this contract/order shall be energy efficient (EnergyStar or Federal Energy Management Program - FEMP-designated products), water efficient, biobased, environmentally preferable (excluding EPEAT-registered products), non-ozone depleting, contain recycled content, or are non- or low toxic alternatives or hazardous constituents (e.g., non-VOC paint), where such products and services meet agency performance requirements. See: Executive Order (EO) 13693, "Planning for Federal Sustainability in the Next Decade."
(b) The NRC and contractor may negotiate during the contract term to permit the substitution or addition of designated recycled content products (i.e., Comprehensive Procurement Guidelines - CPG), EPEAT-registered products, EnergyStar- and FEMP designated energy efficient products and appliances, USDA designated biobased products (Biopreferred program), environmentally preferable products, WaterSense and other water efficient products, products containing non- or lower-ozone depleting substances (i.e., SNAP), and products containing non- or low-toxic or hazardous constituents (e.g., non-VOC paint), when such products and services are readily available at a competitive cost and satisfy the NRCs performance needs.
(c) The contractor shall flow down this clause into all subcontracts and other agreements that relate to performance of this contract/order.
H.14 NRCH440 CONTRACTOR RESPONSIBILITY FOR PROTECTING PERSONALLY IDENTIFIABLE INFORMATION (PII)
Page 37 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 0
In accordance with the Office of Management and Budget's guidance to Federal agencies and the Nuclear Regulatory Commission's (NRC) implementing policy and procedures, a contractor (including subcontractors and contractor employees), who performs work on behalf of the NRC, is responsible for protecting, from unauthorized access or disclosure, personally identifiable information (PII) that may be provided, developed, maintained, collected, used, or disseminated, whether in paper, electronic, or other format, during performance of this contract.
A contractor who has access to NRC owned or controlled PII, whether provided to the contractor by the NRC or developed, maintained, collected, used, or disseminated by the contractor during the course of contract performance, must comply with the following requirements:
(1) General. In addition to implementing the specific requirements set forth in this clause, the contractor must adhere to all other applicable NRC guidance, policy and requirements for the handling and protection of NRC owned or controlled PII. The contractor is responsible for making sure that it has an adequate understanding of such guidance, policy and requirements.
(2) Use, Ownership, and Nondisclosure. A contractor may use NRC owned or controlled PII solely for purposes of this contract, and may not collect or use such PII for any purpose outside the contract without the prior written approval of the NRC Contracting Officer. The contractor must restrict access to such information to only those contractor employees who need the information to perform work under this contract, and must ensure that each such contractor employee (including subcontractors' employees) signs a nondisclosure agreement, in a form suitable to the NRC Contracting Officer, prior to being granted access to the information. The NRC retains sole ownership and rights to its PII. Unless the contract states otherwise, upon completion of the contract, the contractor must turn over all PII in its possession to the NRC, and must certify in writing that it has not retained any NRC owned or controlled PII except as otherwise authorized in writing by the NRC Contracting Officer.
(3) Security Plan. When applicable, and unless waived in writing by the NRC Contracting Officer, the contractor must work with the NRC to develop and implement a security plan setting forth adequate procedures for the protection of NRC owned or controlled PII as well as the procedures which the contractor must follow for notifying the NRC in the event of any security breach. The plan will be incorporated into the contract and must be implemented and followed by the contractor once it has been approved by the NRC Contracting Officer. If the contract does not include a security plan at the time of contract award, a plan must be submitted for the approval of the NRC Contracting Officer within 30 days after contract award.
(4) Breach Notification. The contractor must immediately notify the NRC Contracting Officer and the NRC Contracting Officers Representative (COR) upon discovery of any suspected or confirmed breach in the security of NRC owned or controlled PII.
(5) Legal Demands for Information. If a legal demand is made for NRC owned or controlled PII (such as by subpoena), the contractor must immediately notify the NRC Contracting Officer and the NRC Contracting Officers Representative (COR). After notification, the NRC will determine whether and to what extent to comply with the legal demand. The Contracting Officer will then notify the contractor in writing of the determination and such notice will indicate the extent of disclosure authorized, if any. The contractor may only release the information specifically demanded with the written permission of the NRC Contracting Officer.
(6) Audits. The NRC may audit the contractor's compliance with the requirements of this clause, including through the use of online compliance software.
(7) Flow-down. The prime contractor will flow this clause down to subcontractors that would be covered by any portion of this clause, as if they were the prime contractor.
Page 38 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (8) Remedies:
(a) The contractor is responsible for implementing and maintaining adequate security controls to prevent the loss of control or unauthorized disclosure of NRC owned or controlled PII in its possession. Furthermore, the contractor is responsible for reporting any known or suspected loss of control or unauthorized access to PII to the NRC in accordance with the provisions set forth in Article 4 above.
(b) Should the contractor fail to meet its responsibilities under this clause, the NRC reserves the right to take appropriate steps to mitigate the contractor's violation of this clause. This may include, at the sole discretion of the NRC, termination of the subject contract.
(9) Indemnification. Notwithstanding any other remedies available to the NRC, the contractor will indemnify the NRC against all liability (including costs and fees) for any damages arising out of violations of this clause.
H.15 NRCH430 DRUG FREE WORKPLACE TESTING: UNESCORTED ACCESS TO NUCLEAR FACILITIES, ACCESS TO CLASSIFIED INFORMATION OR SAFEGUARDS INFORMATION, OR PERFORMING IN SPECIALLY SENSITIVE POSITIONS (OCT 2014) 0 All contractor employees, subcontractor employees, applicants, and consultants proposed for performance or performing under this contract shall be subject to pre-assignment, random, reasonable suspicion, and post-accident drug testing applicable to: (1) individuals who require unescorted access to nuclear power plants, (2) individuals who have access to classified or safeguards information, (3) individuals who are required to carry firearms in performing security services for the NRC, (4) individuals who are required to operate government vehicles or transport passengers for the NRC, (5) individuals who are required to operate hazardous equipment at NRC facilities, or (6) individuals who admit to recent illegal drug use or those who are found through other means to be using drugs illegally.
The NRC Drug Program Manager will schedule the drug testing for all contractor employees, subcontractor employees, applicants, and consultants who are subject to testing under this clause. The consequences of refusing to undergo drug testing or a refusal to cooperate in such testing, including not appearing at the scheduled appointment time, will result in the Agencys refusal of the contractor employee to work under any NRC contract. Any NRC contractor employee found to be using, distributing or possessing illegal drugs, or any contractor employee who fails to receive a verified negative drug test result under this program while in a duty status will immediately be removed from working under the NRC contract. The contractor's employer will be notified of the denial or revocation of the individual's authorization to have access to information and ability to perform under the contract. The individual may not work on any NRC contract for a period of not less than one year from the date of the failed, positive drug test and will not be considered for reinstatement unless evidence of rehabilitation, as determined by the NRC "drug testing contractor's" Medical Review Officer, is provided.
Contractor drug testing records are protected under the NRC Privacy Act Systems of Records, System 35, "Drug Testing Program Records - NRC" found at: http://www.nrc.gov/reading-rm/foia/privacy-systems.html H.16 NRCH420 AUTHORITY TO USE GOVERNMENT PROVIDED SPACE AT NRC HEADQUARTERS (SEP 2013)
Prior to occupying any Government provided space at NRC Headquarters in Rockville Maryland, the Contractor shall obtain written authorization to occupy specifically designated government space, via the NRC Contracting Officers Representative (COR), from the Chief, Space Design Branch, Office of Administration.
Failure to obtain this prior authorization can result in one, or a combination, of the following remedies as deemed appropriate by the Contracting Officer.
Page 39 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (1) Rental charge for the space occupied will be deducted from the invoice amount due the Contractor (2) Removal from the space occupied (3) Contract Termination H.17 NRCH410 WHISTLEBLOWER PROTECTION FOR NRC CONTRACTOR AND SUBCONTRACTOR EMPLOYEES (a) The U.S. Nuclear Regulatory Commission (NRC) contractor and its subcontractor are subject to the Whistleblower Employee Protection public law provisions as codified at 42 U.S.C. 5851. NRC contractor(s) and subcontractor(s) shall comply with the requirements of this Whistleblower Employee Protection law, and the implementing regulations of the NRC and the Department of Labor (DOL). See, for example, DOL Procedures on Handling Complaints at 29 C.F.R. Part 24 concerning the employer obligations, prohibited acts, DOL procedures and the requirement for prominent posting of notice of Employee Rights at Appendix A to Part 24 entitled: Your Rights Under the Energy Reorganization Act.
(b) Under this Whistleblower Employee Protection law, as implemented by regulations, NRC contractor and subcontractor employees are protected from discharge, reprisal, threats, intimidation, coercion, blacklisting or other employment discrimination practices with respect to compensation, terms, conditions or privileges of their employment because the contractor or subcontractor employee(s) has provided notice to the employer, refused to engage in unlawful practices, assisted in proceedings or testified on activities concerning alleged violations of the Atomic Energy Act of 1954 (as amended) and the Energy Reorganization Act of 1974 (as amended).
(c) The contractor shall insert this or the substance of this clause in any subcontracts involving work performed under this contract.
H.18 NRCH400 SECURITY REQUIREMENTS RELATING TO THE PRODUCTION OF REPORT(S) OR THE PUBLICATION OF RESULTS UNDER CONTRACTS, AGREEMENTS, AND GRANTS Review and Approval of Reports (a) Reporting Requirements. The contractor/grantee shall comply with the terms and conditions of the contract/grant regarding the contents of the draft and final report, summaries, data, and related documents, to include correcting, deleting, editing, revising, modifying, formatting, and supplementing any of the information contained therein, at no additional cost to the NRC. Performance under the contract/grant will not be deemed accepted or completed until it complies with the NRCs directions. The reports, summaries, data, and related documents will be considered draft until approved by the NRC. The contractor/grantee agrees that the direction, determinations, and decisions on approval or disapproval of reports, summaries, data, and related documents created under this contract/grant remain solely within the discretion of the NRC.
(b) Publication of Results. Prior to any dissemination, display, publication, or release of articles, reports, summaries, data, or related documents developed under the contract/grant, the contractor/grantee shall submit them to the NRC for review and approval. The contractor/ grantee shall not release, disseminate, display or publish articles, reports, summaries, data, and related documents, or the contents therein, that have not been reviewed and approved by the NRC for release, display, dissemination or publication. The contractor/grantee agrees to conspicuously place any disclaimers, markings or notices, directed by the NRC, on any articles, reports, summaries, data, and related documents that the contractor/grantee intends to release, display, disseminate or publish to other persons, the public, or any other entities. The contractor/grantee agrees, and Page 40 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 grants, a royalty-free, nonexclusive, irrevocable worldwide license to the government, to use, reproduce, modify, distribute, prepare derivative works, release, display or disclose the articles, reports, summaries, data, and related documents developed under the contract/grant, for any governmental purpose and to have or authorize others to do so.
(c) Identification/Marking of Sensitive Unclassified Non-Safeguards Information (SUNSI) and Safeguards Information (SGI). The decision, determination, or direction by the NRC that information possessed, formulated or produced by the contractor/grantee constitutes SUNSI or SGI is solely within the authority and discretion of the NRC. In performing the contract/grant, the contractor/grantee shall clearly mark SUNSI and SGI, to include for example, OUO-Allegation Information or OUO-Security Related Information on any reports, documents, designs, data, materials, and written information, as directed by the NRC. In addition to marking the information as directed by the NRC, the contractor shall use the applicable NRC cover sheet (e.g., NRC Form 461 Safeguards Information) in maintaining these records and documents. The contractor/grantee shall ensure that SUNSI and SGI is handled, maintained and protected from unauthorized disclosure, consistent with NRC policies and directions. The contractor/grantee shall comply with the requirements to mark, maintain, and protect all information, including documents, summaries, reports, data, designs, and materials in accordance with the provisions of Section 147 of the Atomic Energy Act of 1954 as amended, its implementing regulations (10 CFR 73.21), Sensitive Unclassified Non-Safeguards and Safeguards Information policies, and NRC Management Directives and Handbooks 12.5, 12.6 and 12.7.
(d) Remedies. In addition to any civil, criminal, and contractual remedies available under the applicable laws and regulations, failure to comply with the above provisions, and/or NRC directions, may result in suspension, withholding, or offsetting of any payments invoiced or claimed by the contractor/grantee.
(e) Flowdown. If the contractor/grantee intends to enter into any subcontracts or other agreements to perform this contract/grant, the contractor/grantee shall include all of the above provisions in any subcontracts or agreements.
H.19 NRCH390 NRC INFORMATION TECHNOLOGY SECURITY NRC INFORMATION TECHNOLOGY SECURITY TRAINING (MAY 2016)
NRC contractors shall ensure that their employees, consultants, and subcontractors with access to the agency's information technology (IT) equipment and/or IT services complete NRC's online initial and refresher IT security training requirements to ensure that their knowledge of IT threats, vulnerabilities, and associated countermeasures remains current. Both the initial and refresher IT security training courses generally last an hour or less and can be taken during the employee's regularly scheduled work day.
Contractor employees, consultants, and subcontractors shall complete the NRC's online annual, "Computer Security Awareness" course on the same day that they receive access to the agency's IT equipment and/or services, as their first action using the equipment/service. For those contractor employees, consultants, and subcontractors who are already working under this contract, the on-line training must be completed in accordance with agency Network Announcements issued throughout the year, within three weeks of issuance of this modification.
Additional annual required online NRC training includes but is not limited to the following:
(1) Information Security (INFOSEC) Awareness (2) Continuity of Operations (COOP) Awareness (3) Defensive Counterintelligence and Insider Threat Awareness (4) No FEAR Act (5) Personally Identifiable Information (PII) and Privacy Act Responsibilities Awareness Page 41 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Contractor employees, consultants, and subcontractors who have been granted access to NRC information technology equipment and/or IT services must continue to take IT security refresher training offered online by the NRC throughout the term of the contract. Contractor employees will receive notice of NRC's online IT security refresher training requirements through agency-wide notices.
Contractor Monthly Letter Status Reports (MLSR) must include the following information for all completed training:
(1) the name of the individual completing the course; (2) the course title; and (3) the course completion date.
The MLSR must also include the following information for those individuals who have not completed their required training:
(1) the name of the individual who has not yet completed the training; (2) the title of the course(s) which must still be completed; and (3) the anticipated course completion date(s).
The NRC reserves the right to deny or withdraw Contractor use or access to NRC IT equipment and/or services, and/or take other appropriate contract administrative actions (e.g., disallow costs, terminate for cause) should the Contractor violate the Contractor's responsibility under this clause.
H.20 NRCH380 SECURITY REQUIREMENTS FOR ACCESS TO CLASSIFIED MATTER OR INFORMATION (SEP 2013)
Performance under this contract will require access to classified matter or information (National Security Information or Restricted Data) in accordance with the attached NRC Form 187 (See List of Attachments).
Prime Contractor personnel, subcontractors or others performing work under this contract shall require a "Q" security clearance (allows access to Top Secret, Secret, and Confidential National Security Information and Restricted Data) or an "L" security clearance (allows access to Secret and Confidential National Security Information and/or Confidential Restricted Data).
The Contractor must identify all individuals to work under this contract. The NRC sponsoring office shall make the final determination of the type of security clearance required for all individuals working under this contract.
The Contractor shall conduct a preliminary security interview or review for each of its employees, subcontractor employees and consultants, and submit to the Government only the names of candidates that have a reasonable probability of obtaining the level of security clearance for which the candidate has been proposed.
The Contractor will pre-screen applicants for the following:
(a) pending criminal charges or proceedings; (b) felony arrest records including alcohol related arrest within the last seven (7) years; (c) record of any military courts-martial charges and proceedings in the last seven (7) years and courts-martial convictions in the last ten (10) years; (d )any involvement in hate crimes; (e) involvement in any group or organization that espouses extra-legal violence as a legitimate means to an end; (f) dual or multiple citizenship including the issuance of a foreign passport in the last seven (7) years; (g) illegal use possession, or distribution of narcotics or other controlled substances within the last seven (7) years; (h) financial issues regarding delinquent debts, liens, garnishments, bankruptcy and civil court actions in the last seven (7) years.
The Contractor will make a written record of their pre-screening interview or review (including any information Page 42 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 to mitigate the responses to items listed in (a) - (h)), and have the candidate verify the record, sign and date it.
Two (2) copies of the signed interview record or review will be supplied to DFS/PSB with the applicant's completed security application package.
The Contractor will further ensure that all Contractor employees, subcontractor employees and consultants for classified information access approval complete all security applications required by this clause within fourteen (14) calendar days of notification by DFS/PSB of initiation of the application process. Timely receipt of properly completed security applications (submitted for candidates that have a reasonable probability of obtaining the level of security clearance for which the candidate has been proposed) is a contract requirement.
Failure of the Contractor to comply with this condition may be a basis to cancel the award, or terminate the contract for default, or offset from the contract's invoiced cost or price the NRC's incurred costs or delays as a result of inadequate pre-screening by the Contractor. In the event of termination or cancellation, the Government may select another firm for contract award.
Such Contractor personnel shall be subject to the NRC Contractor personnel security requirements of NRC Management Directive (MD) 12.3, Part I and 10 CFR Part 10.11, which is hereby incorporated by reference and made a part of this contract as though fully set forth herein, and will require a favorably adjudicated Single Scope Background Investigation (SSBI) for "Q" clearances or a favorably adjudicated Access National Agency Check and Inquiries (ANACI), or higher level investigation depending on the position the individual will occupy, for "L" clearances.
A Contractor employee shall not have access to classified information until he/ she is granted a security clearance by DFS/PSB, based on a favorably adjudicated investigation. In the event the Contractor employee's investigation cannot be favorably adjudicated, any interim access approval could possibly be revoked and the individual could be subsequently removed from performing under the contract. If interim approval access is revoked or denied, the Contractor is responsible for assigning another individual to perform the necessary work under this contract without delay to the contract's performance schedule, or without adverse impact to any other terms or conditions of the contract. The individual will be subject to a reinvestigation every five (5) years for "Q" clearances and every ten (10) years for "L" clearances.
CORs are responsible for submitting the completed access/clearance request package as well as other documentation that is necessary to DFS/PSB. The contractor shall submit a completed security forms packet, including the OPM Standard Form (SF) 86 (online Questionnaire for National Security Positions), two (2) copies of the Contractor's signed pre-screening record and two (2) FD 258 fingerprint charts, to DFS/PSB for review and adjudication, prior to submission to the Office of Personnel Management for investigation. The individual may start working under this contract before a final clearance is granted if a temporary access determination can be made by DFS/PSB after the review of the security package. If the individual is granted a temporary access authorization, the individual may not have access to classified information under this contract until DFS/PSB has granted them the appropriate security clearance, and the Contractor has read, understood, and signed the SF 312, "Classified Information Nondisclosure Agreement." The Contractor shall assure that all forms are accurate, complete, and legible (except for Part 2 of the questionnaire, which is required to be completed in private and submitted by the individual to the Contractor in a sealed envelope), as set forth in NRC MD 12.3. Based on DFS/PSB review of the applicant's investigation, the individual may be denied his/her security clearance in accordance with the due process procedures set forth in MD 12.3, E.O.
12968, and 10 CFR Part 10.11.
In accordance with NRCAR 2052.204-70 cleared Contractors shall be subject to the attached NRC Form 187 (See Section J for List of Attachments), MD 12.3, SF- 86 and Contractor's signed record or review of the pre-screening which furnishes the basis for providing security requirements to prime Contractors, subcontractors or others who have or may have an NRC contractual relationship which requires access to classified information.
CANCELLATION OR TERMINATION OF SECURITY CLEARANCE ACCESS/REQUEST Page 43 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 When a request for clearance investigation is to be withdrawn or canceled, the Contractor shall immediately notify the COR by telephone so that the investigation may be promptly discontinued. The notification shall contain the full name of the individual, and the date of the request. Telephone notifications must be promptly confirmed in writing by the Contractor to the COR who will forward the confirmation via email to DFS/PSB.
Additionally, DFS/PSB must be immediately notified in writing when an individual no longer requires access to Government classified information, including the voluntary or involuntary separation of employment of an individual who has been approved for or is being processed for access under the NRC "Personnel Security Program."
H.21 NRCH370 SAFETY OF ON-SITE CONTRACTOR PERSONNEL Ensuring the safety of occupants of Federal buildings is a responsibility shared by the professionals implementing our security and safety programs and the persons being protected. The NRC's Office of Administration (ADM) Division of Facilities and Security (DFS) has coordinated an Occupant Emergency Plan (OEP) for NRC Headquarters buildings with local authorities. The OEP has been approved by the Montgomery County Fire and Rescue Service. It is designed to improve building occupants' chances of survival, minimize damage to property, and promptly account for building occupants when necessary.
The contractor's Project Director shall ensure that all personnel working full time on-site at NRC Headquarters read the NRC's OEP, provided electronically on the NRC Intranet at http://www.internal.nrc.gov/ADM/OEP.pdf.
The contractor's Project Director also shall emphasize to each staff member that they are to be familiar with and guided by the OEP, as well as by instructions given by emergency response personnel in situations which pose an immediate health or safety threat to building occupants.
The NRC Contracting Officers Representative (COR) shall ensure that the contractor's Project Director has communicated the requirement for on-site contractor staff to follow the guidance in the OEP. The NRC Contracting Officers Representative (COR) also will assist in accounting for on-site contract persons in the event of a major emergency (e.g., explosion occurs and casualties or injuries are suspected) during which a full evacuation will be required, including the assembly and accountability of occupants. The NRC DFS will conduct drills periodically to train occupants and assess these procedures.
H.22 NRCH360 INTERNET Neither NRC nor its third party contractors that manage or develop the NRC web site shall send persistent cookies, place persistent cookies on users' computers, nor collect personally identifiable information from visitors to the NRC web site unless in addition to clear and conspicuous notice, each of the following conditions are met: there is a compelling need to gather the data on the site; there are appropriate and publicly disclosed privacy safeguards for handling of information derived from "cookies"; and personal approval is obtained from the head of the agency.
H.23 NRCH340 COMPLIANCE WITH U.S. IMMIGRATION LAWS AND REGULATIONS NRC contractors are responsible to ensure that their alien personnel are not in violation of United States immigration laws and regulations, including employment authorization documents and visa requirements.
Each alien employee of the Contractor must be lawfully admitted for permanent residence as evidenced by Permanent Resident Form I-551 (Green Card), or must present other evidence from the U.S. Department of Homeland Security/U.S. Citizenship and Immigration Services that employment will not affect his/her immigration status. The U.S. Citizenship and Immigration Services provides information to contractors to help Page 44 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 them understand the employment eligibility verification process for non-US citizens. This information can be found on their website, http://www.uscis.gov/portal/site/uscis.
The NRC reserves the right to deny or withdraw Contractor use or access to NRC facilities or its equipment/services, and/or take any number of contract administrative actions (e.g., disallow costs, terminate for cause) should the Contractor violate the Contractor's responsibility under this clause.
H.24 NRCH330 RULES OF BEHAVIOR FOR AUTHORIZED COMPUTER USE In accordance with Appendix III, "Security of Federal Automated Information Resources," to Office of Management and Budget (OMB) Circular A-130, "Management of Federal Information Resources," NRC has established rules of behavior for individual users who access all IT computing resources maintained and operated by the NRC or on behalf of the NRC. In response to the direction from OMB, NRC has issued the "Agency-wide Rules of Behavior for Authorized Computer Use" policy, hereafter referred to as the rules of behavior. The rules of behavior for authorized computer use will be provided to NRC computer users, including contractor personnel, as part of the annual computer security awareness course.
The rules of behavior apply to all NRC employees, contractors, vendors, and agents (users) who have access to any system operated by the NRC or by a contractor or outside entity on behalf of the NRC. This policy does not apply to licensees. The next revision of Management Directive 12.5, "NRC Automated Information Security Program," will include this policy. The rules of behavior can be viewed at http://www.internal.nrc.gov/CSO/documents/ROB.pdf or use NRCs external Web-based ADAMS at http://wba.nrc.gov:8080/ves/ (Under Advanced Search, type ML082190730 in the Query box).
The rules of behavior are effective immediately upon acknowledgement of them by the person who is informed of the requirements contained in those rules of behavior. All current contractor users are required to review and acknowledge the rules of behavior as part of the annual computer security awareness course completion.
All new NRC contractor personnel will be required to acknowledge the rules of behavior within one week of commencing work under this contract and then acknowledge as current users thereafter. The acknowledgement statement can be viewed at http://www.internal.nrc.gov/CSO/documents/ROB_Ack.pdf or use NRCs external Web-based ADAMS at http://wba.nrc.gov:8080/ves/ (Under Advanced Search, type ML082190730 in the Query box).
The NRC Computer Security Office will review and update the rules of behavior annually beginning in FY 2011 by December 31st of each year. Contractors shall ensure that their personnel to which this requirement applies acknowledge the rules of behavior before beginning contract performance and, if the period of performance for the contract lasts more than one year, annually thereafter. Training on the meaning and purpose of the rules of behavior can be provided for contractors upon written request to the NRC Contracting Officers Representative (COR).
The contractor shall flow down this clause into all subcontracts and other agreements that relate to performance of this contract/order if such subcontracts/agreements will authorize access to NRC electronic and information technology (EIT) as that term is defined in FAR 2.101.
H.25 NRCH310 ANNUAL AND FINAL CONTRACTOR PERFORMANCE EVALUATIONS Annual and final evaluations of contractor performance under this contract will be prepared in accordance with FAR Subpart 42.15, "Contractor Performance Information," normally at or near the time the contractor is notified of the NRC's intent to exercise the contract option. If the multi-year contract does not have option years, then an annual evaluation will be prepared [Insert time for annual evaluation here]. Final evaluations of Page 45 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 contractor performance will be prepared at the expiration of the contract during the contract closeout process.
The Contracting Officer will transmit the NRC Contracting Officers Representatives (COR) annual and final contractor performance evaluations to the contractor's Project Manager, unless otherwise instructed by the contractor. The contractor will be permitted thirty days to review the document and submit comments, rebutting statements, or additional information.
Where a contractor concurs with, or takes no exception to an annual performance evaluation, the Contracting Officer will consider such evaluation final and releasable for source selection purposes. Disagreements between the parties regarding a performance evaluation will be referred to an individual one level above the Contracting Officer, whose decision will be final.
The Contracting Officer will send a copy of the completed evaluation report, marked "Source Selection Information, to the contractor's Project Manager for their records as soon as practicable after it has been finalized. The completed evaluation report also will be used as a tool to improve communications between the NRC and the contractor and to improve contract performance.
The completed annual performance evaluation will be used to support future award decisions in accordance with FAR 42.1502 and 42.1503. During the period the information is being used to provide source selection information, the completed annual performance evaluation will be released to only two parties - the Federal government personnel performing the source selection evaluation and the contractor under evaluation if the contractor does not have a copy of the report already.
H.26 NRCH130 DENIAL OF FEDERAL BENEFITS TO INDIVIDUALS CONVICTED OF DRUG TRAFFICKING OR POSSESSION In the event that an award is made to an individual, Section 5301 of the Anti-Drug Abuse Act of 1988 (P.L. 100-690), codified at 21 U.S.C. 862, authorizes denial of Federal benefits such as grants, contracts, purchase orders, financial aid, and business and professional licenses to individuals convicted of drug trafficking or possession.
H.27 NRCH039 IT SECURITY REQUIREMENTS - NRC AND CONTRACTOR (NON-NRC) FACILITIES (APR 2014)
Backups The contractor shall ensure that backup media is created, encrypted (in accordance with information sensitivity) and verified to ensure that data can be retrieved and is restorable to NRC systems based on information sensitivity levels. Backups shall be executed to create readable media that allows successful file/data restoration at the following frequencies:
- At least every 1 calendar day for a high sensitivity system
- At least every 1 calendar day for a moderate sensitivity system
- At least every 7 calendar days for a low sensitivity system Perimeter Protection The Contractor must employ perimeter protection mechanisms, such as firewalls and routers, to deny all communications unless explicitly allowed by exception.
Page 46 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 The contractor must deploy and monitor intrusion detection capability and have an always deployed and actively engaged security monitoring capability in place for systems placed in operation for the NRC.
Intrusion detection and monitoring reports will made available to the NRC upon request for following security categorizations and reporting timeframes:
- 5 calendar days after being requested for a high sensitivity system
- 10 calendar days after being requested for a moderate sensitivity system
- 15 calendar days after being requested for a low sensitivity system H.28 INFORMATION TECHNOLOGY (IT) SECURITY REQUIREMENTS - GENERAL EXCEPTIONS All purchases shall comply with the latest version of policy, procedures and standards. Individual task orders will reference latest versions of policy, procedures, standards or exceptions as necessary. These policy, procedures and standards include: NRC Management Directive (MD) volume 12 Security, Computer Security Office policies, procedures and standards, National Institute of Standards and Technology (NIST) guidance and Federal Information Processing Standards (FIPS), and Committee on National Security Systems (CNSS) policy, directives, instructions, and guidance. This information is available at the following links:
All procurements must be certified and accredited prior to being placed into an operational state.
All electronic processing of NRC sensitive information, including all system development and operations and maintenance activities performed at non-NRC facilities shall be in facilities, networks, and computers that have been accredited by NRC for processing information at the highest sensitivity of the information that is processed or will ultimately be processed.
All systems used to process NRC sensitive information shall meet NRC configuration standards available at:
http://www.internal.nrc.gov/CSO/standards.html .
H.29 NRCH032 INFORMATION TECHNOLOGY (IT) SECURITY REQUIREMENTS - GENERAL (APR 2014)
Basic Contract IT Security Requirements The contractor agrees to insert terms that conform substantially to the language of the IT security requirements, excluding any reference to the Changes clause of this contract, all subcontracts under this contract.
For unclassified information used for the effort, the contractor shall provide an information security categorization document indicating the sensitivity of the information processed as part of this contract if the information security categorization was not provided in the statement of work. The determination shall be made using National Institute of Standards and Technology (NIST) Special Publication (SP) 800-60 and must be approved by CSO. The NRC contracting officer and Contracting Officers Representative (COR) shall be notified immediately before the contractor begins to process information at a higher sensitivity level.
If the effort includes use or processing of classified information, the NRC contracting officer and Contracting Officers Representative (COR) shall be notified before the contractor begins to process information at a more restrictive classification level.
All work under this contract shall comply with the latest version of policy, procedures and standards. Individual task orders will reference latest versions of standards or exceptions as necessary. These policy, procedures Page 47 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 and standards include: NRC Management Directive (MD) volume 12 Security, Computer Security Office policies, procedures and standards, National Institute of Standards and Technology (NIST) guidance and Federal Information Processing Standards (FIPS), and Committee on National Security Systems (CNSS) policy, directives, instructions, and guidance. This information is available at the following links:
NRC Policies, Procedures and Standards (CSO internal website):
http://www.internal.nrc.gov/CSO/policies.html All NRC Management Directives (public website):
http://www.nrc.gov/reading-rm/doc-collections/management-directives/
NIST SP and FIPS documentation is located at:
CNSS documents are located at:
When e-mail is used, the Contractors shall only use NRC provided e-mail accounts to send and receive sensitive information (information that is not releasable to the public) or mechanisms to protect the information during transmission to NRC that have been approved by CSO.
All Contractor employees must sign the NRC Agency-Wide Rules of Behavior for Authorized Computer Use prior to being granted access to NRC computing resources.
The Contractor shall adhere to following NRC policies, including but not limited to:
- Management Directive 12.5, Automated Information Security Program
- Computer Security Policy for Encryption of Data at Rest When Outside of Agency Facilities
- Policy for Copying, Scanning, Printing, and Faxing SGI & Classified Information
- Computer Security Information Protection Policy
- Remote Access Policy
- Use of Commercial Wireless Devices, Services and Technologies Policy
- Laptop Security Policy
- Computer Security Incident Response Policy Contractor will adhere to NRCs prohibition of use of personal devices to process and store NRC sensitive information.
All work performed at non-NRC facilities shall be in facilities, networks, and computers that have been accredited by NRC for processing information at the sensitivity level of the information being processed.
Page 48 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Contract Performance and Closeout The contractor shall ensure that the NRC data processed during the performance of this contract shall be purged from all data storage components of the contractors computer facility, and the contractor will retain no NRC data within 30 calendar days after contract is completed. Until all data is purged, the contractor shall ensure that any NRC data remaining in any storage component will be protected to prevent unauthorized disclosure.
When contractor employees no longer require access to an NRC system, the contractor shall notify the Contracting Officers Representative (COR) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Upon contract completion, the contractor shall provide a status list of all contractor employees who were users of NRC systems and shall note if any users still require access to the system to perform work if a follow-on contract or task order has been issued by NRC.
Control of Information and Data The contractor shall not publish or disclose in any manner, without the contracting officers written consent, the details of any security controls or countermeasures either designed or developed by the contractor under this contract or otherwise provided by the NRC.
Any IT system used to process NRC sensitive information shall:
- Include a mechanism to require users to uniquely identify themselves to the system before beginning to perform any other actions that the system is expected to provide.
- Be able to authenticate data that includes information for verifying the claimed identity of individual users (e.g., passwords).
- Protect authentication data so that it cannot be accessed by any unauthorized user.
- Be able to enforce individual accountability by providing the capability to uniquely identify each individual computer system user.
- Report to appropriate security personnel when attempts are made to guess the authentication data whether inadvertently or deliberately.
Access Controls Any contractor system being used to process NRC data shall be able to define and enforce access privileges for individual users. The discretionary access controls mechanisms shall be configurable to protect objects (e.g., files, folders) from unauthorized access.
The contractor system being used to process NRC data shall provide only essential capabilities and specifically prohibit and/or restrict the use of specified functions, ports, protocols, and/or services.
The contractors shall only use NRC approved methods to send and receive information considered sensitive or classified. Specifically, Page 49 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- Classified Information - All NRC Classified data being transmitted over a network shall use NSA approved encryption and adhere to guidance in MD 12.2 NRC Classified Information Security Program, MD 12.5 NRC Automated Information Security Program and Committee on National Security Systems. Classified processing shall be only within facilities, computers, and spaces that have been specifically approved for classified processing.
- SGI Information - All SGI being transmitted over a network shall adhere to guidance in MD 12.7 NRC Safeguards Information Security Program and MD 12.5 NRC Automated Information Security Program. SGI processing shall be only within facilities, computers, and spaces that have been specifically approved for SGI processing. Cryptographic modules provided as part of the system shall be validated under the Cryptographic Module Validation Program to conform to NIST FIPS 140-2 overall level 2 and must be operated in FIPS mode.
The contractor shall provide the FIPS 140-2 cryptographic module certificate number and a brief description of the encryption module that includes the encryption algorithm(s) used, the key length, and the vendor of the product.
The most restrictive set of rights/privileges or accesses needed by users (or processes acting on behalf of users) for the performance of specified tasks must be enforced by the system through assigned access authorizations.
Separation of duties for contractor systems used to process NRC information must be enforced by the system through assigned access authorizations.
The mechanisms within the contractor system or application that enforces access control and other security features shall be continuously protected against tampering and/or unauthorized changes.
Configuration Standards All systems used to process NRC sensitive information shall meet NRC configuration standards available at:
http://www.internal.nrc.gov/CSO/standards.html.
Information Security Training and Awareness Training Contractors shall ensure that their employees, consultants, and subcontractors that have significant IT responsibilities (e.g., IT administrators, developers, project leads) receive in-depth IT security training in their area of responsibility. This training is at the employers expense.
Media Handling All media used by the contractor to store or process NRC information shall be controlled in accordance with the sensitivity level.
The contractor shall not perform sanitization or destruction of media approved for processing NRC information designated as SGI or Classified. The contractor must provide the media to NRC for destruction.
Vulnerability Management Page 50 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 The Contractor must adhere to NRC patch management processes for all systems used to process NRC information. Patch Management reports will made available to the NRC upon request for following security categorizations and reporting timeframes:
- 5 calendar days after being requested for a high sensitivity system
- 10 calendar days after being requested for a moderate sensitivity system
- 15 calendar days after being requested for a low sensitivity system For any contractor system used to process NRC information, the contractor must ensure that information loaded into the system is scanned for viruses prior to posting; servers are scanned for viruses, adware, and spyware on a regular basis; and virus signatures are updated at the following frequency:
- 1 calendar day for a high sensitivity system
- 3 calendar days for a moderate sensitivity system
- 7 calendar days for a low sensitivity system H.30 NRCH030 SECURITY REQUIREMENTS FOR INFORMATION TECHNOLOGY LEVEL I OR LEVEL II ACCESS APPROVAL (SEP 2013)
The contractor must identify all individuals selected to work under this contract. The NRC Contracting Officers Representative (COR) shall make the final determination of the level, if any, of IT access approval required for all individuals working under this contract/order using the following guidance. The Government shall have full and complete control and discretion over granting, denying, withholding, or terminating IT access approvals for contractor personnel performing work under this contract/order.
The contractor shall conduct a preliminary security interview or review for each employee requiring IT level I or II access and submit to the Government only the names of candidates that have a reasonable probability of obtaining the level of IT access approval for which the employee has been proposed. The contractor shall pre-screen its applicants for the following:
(a) felony arrest in the last seven (7) years; (b) alcohol related arrest within the last five (5) years; (c) record of any military courts-martial convictions in the past ten (10) years; (d) illegal use of narcotics or other controlled substances possession in the past year, or illegal purchase, production, transfer, or distribution of narcotics or other controlled substances in the last seven (7) years; and (e) delinquency on any federal debts or bankruptcy in the last seven (7) years.
The contractor shall make a written record of its pre-screening interview or review (including any information to mitigate the responses to items listed in (a) - (e)), and have the employee verify the pre-screening record or review, sign and date it. The contractor shall supply two (2) copies of the signed contractor's pre-screening record or review to the NRC Contracting Officers Representative (COR), who will then provide them to the NRC Office of Administration, Division of Facilities and Security, Personnel Security Branch with the employees completed IT access application package.
The contractor shall further ensure that its personnel complete all IT access approval security applications Page 51 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 required by this clause within fourteen (14) calendar days of notification by the NRC Contracting Officers Representative (COR) of initiation of the application process. Timely receipt of properly completed records of the pre-screening record and IT access approval applications (submitted for candidates that have a reasonable probability of obtaining the level of security assurance necessary for access to NRC's IT systems/data) is a requirement of this contract/order. Failure of the contractor to comply with this requirement may be a basis to terminate the contract/order for cause, or offset from the contract's invoiced cost or price the NRC's incurred costs or delays as a result of inadequate pre-screening by the contractor.
SECURITY REQUIREMENTS FOR IT LEVEL I Performance under this contract/order will involve contractor personnel who perform services requiring direct access to or operate agency sensitive information technology systems or data (IT Level I). The IT Level I involves responsibility for the planning, direction, and implementation of a computer security program; major responsibility for the direction, planning, and design of a computer system, including hardware and software; or the capability to access a computer system during its operation or maintenance in such a way that could cause or that has a relatively high risk of causing grave damage; or the capability to realize a significant personal gain from computer access.
Contractor personnel shall not have access to sensitive information technology systems or data until they are approved by DFS/PSB and they have been so informed in writing by the NRC Contracting Officers Representative (COR). Temporary IT access may be approved by DFS/PSB based on a favorable review or adjudication of their security forms and checks. Final IT access may be approved by DFS/PSB based on a favorably review or adjudication of a completed background investigation. However, temporary access authorization approval will be revoked and the employee may subsequently be denied IT access in the event the employees investigation cannot be favorably adjudicated. Such an employee will not be authorized to work under any NRC contract/order requiring IT access without the approval of DFS/PSB, as communicated in writing to the contractor by the NRC Contracting Officers Representative (COR). Where temporary access authorization has been revoked or denied by DFS/PSB, the contractor shall assign another contractor employee to perform the necessary work under this contract/order without delay to the contract/order performance schedule, or without adverse impact to any other terms or conditions of the contract/order.
When an individual receives final IT access approval from DFS/PSB, the individual will be subject to a reinvestigation every ten (10) years thereafter (assuming continuous performance under contract/order at NRC) or more frequently in the event of noncontinuous performance under contract/order at NRC.
CORs are responsible for submitting the completed access/clearance request package as well as other documentation that is necessary to DFS/PSB. The contractor shall submit a completed security forms packet, including the OPM Standard Form (SF) 86 (online Questionnaire for National Security Positions), two (2) copies of the Contractor's signed pre-screening record and two (2) FD 258 fingerprint charts, to DFS/PSB for review and adjudication, prior to the individual being authorized to perform work under this contract/order requiring access to sensitive information technology systems or data. Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Employment Authorization Card, or other official documentation issued by the U.S. Citizenship and Immigration Services. Any applicant with less than seven (7) years residency in the U.S. will not be approved for IT Level I access. The Contractor shall submit the documents to the NRC Contracting Officers Representative (COR) who will give them to DFS/PSB. The contractor shall ensure that all forms are accurate, complete, and legible. Based on DFS/PSB review of the contractor employees security forms and/or the receipt of adverse information by NRC, the contractor individual may be denied access to NRC facilities and sensitive information technology systems or data until a final determination is made by DFS/PSB and thereafter communicated to the contractor by the NRC Contracting Officers Representative (COR) regarding the contractor persons eligibility.
In accordance with NRCAR 2052.204-70 "Security," IT Level I contractors shall be subject to the attached NRC Page 52 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Form 187 and SF-86 which furnishes the basis for providing security requirements to contractors that have or may have an NRC contractual relationship which requires access to or operation of agency sensitive information technology systems or remote development and/or analysis of sensitive information technology systems or data or other access to such systems and data; access on a continuing basis (in excess more than 30 calendar days) to NRC buildings; or otherwise requires issuance of an unescorted NRC badge.
SECURITY REQUIREMENTS FOR IT LEVEL II Performance under this contract/order will involve contractor personnel that develop and/or analyze sensitive information technology systems or data or otherwise have access to such systems or data (IT Level II).
The IT Level II involves responsibility for the planning, design, operation, or maintenance of a computer system and all other computer or IT positions.
Contractor personnel shall not have access to sensitive information technology systems or data until they are approved by DFS/PSB and they have been so informed in writing by the NRC Contracting Officers Representative (COR). Temporary access may be approved by DFS/PSB based on a favorable review of their security forms and checks. Final IT access may be approved by DFS/PSB based on a favorably adjudication. However, temporary access authorization approval will be revoked and the contractor employee may subsequently be denied IT access in the event the employee's investigation cannot be favorably adjudicated. Such an employee will not be authorized to work under any NRC contract/order requiring IT access without the approval of DFS/PSB, as communicated in writing to the contractor by the NRC Contracting Officers Representative (COR). Where temporary access authorization has been revoked or denied by DFS/PSB, the contractor is responsible for assigning another contractor employee to perform the necessary work under this contract/order without delay to the contract/order performance schedule, or without adverse impact to any other terms or conditions of the contract/order. When a contractor employee receives final IT access approval from DFS/PSB, the individual will be subject to a review or reinvestigation every ten (10) years (assuming continuous performance under contract/order at NRC) or more frequently in the event of noncontinuous performance under contract/order at NRC.
CORs are responsible for submitting the completed access/clearance request package as well as other documentation that is necessary to DFS/PSB. The contractor shall submit a completed security forms packet, including the OPM Standard Form (SF) 86 (online Questionnaire for National Security Positions), two (2) copies of the Contractor's signed pre-screening record and two (2) FD 258 fingerprint charts, to DFS/PSB for review and adjudication, prior to the contractor employee being authorized to perform work under this contract/order. Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Employment Authorization Card, or other official documentation issued by the U.S. Citizenship and Immigration Services.
Any applicant with less than seven (7) years residency in the U.S. will not be approved for IT Level II access.
The Contractor shall submit the documents to the NRC Contracting Officers Representative (COR) who will give them to DFS/PSB. The contractor shall ensure that all forms are accurate, complete, and legible.
Based on DFS/PSB review of the contractor employees security forms and/or the receipt of adverse information by NRC, the contractor employee may be denied access to NRC facilities, sensitive information technology systems or data until a final determination is made by DFS/PSB regarding the contractor persons eligibility.
In accordance with NRCAR 2052.204-70 "Security," IT Level II contractors shall be subject to the attached NRC Form 187, SF-86, and contractor's record of the pre-screening which furnishes the basis for providing security requirements to contractors that have or may have an NRC contractual relationship which requires access to or operation of agency sensitive information technology systems or remote development and/or analysis of sensitive information technology systems or data or other access to such systems or data; access on a continuing basis (in excess of more than 30 calendar days) to NRC buildings; or otherwise requires Page 53 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 issuance of an unescorted NRC badge.
CANCELLATION OR TERMINATION OF IT ACCESS/REQUEST When a request for IT access is to be withdrawn or canceled, the contractor shall immediately notify the NRC Contracting Officers Representative (COR) by telephone so that the access review may be promptly discontinued. The notification shall contain the full name of the contractor employee and the date of the request. Telephone notifications must be promptly confirmed by the contractor in writing to the NRC Contracting Officers Representative (COR), who will forward the confirmation to DFS/PSB. Additionally, the contractor shall immediately notify the NRC Contracting Officers Representative (COR) in writing, who will in turn notify DFS/PSB, when a contractor employee no longer requires access to NRC sensitive automated information technology systems or data, including the voluntary or involuntary separation of employment of a contractor employee who has been approved for or is being processed for IT access.
The contractor shall flow the requirements of this clause down into all subcontracts and agreements with consultants for work that requires them to access NRC IT resources.
H.31 NRCH020 SECURITY REQUIREMENTS FOR BUILDING ACCESS APPROVAL (SEP 2013)
The Contractor shall ensure that all its employees, subcontractor employees or consultants who are assigned to perform the work herein for contract performance for periods of more than 30 calendar days at NRC facilities, are approved by the NRC for unescorted NRC building access.
The Contractor shall conduct a preliminary federal facilities security screening interview or review for each of its employees, subcontractor employees, and consultants and submit to the NRC only the names of candidates for contract performance that have a reasonable probability of obtaining approval necessary for access to NRC's federal facilities. The Contractor shall pre-screen its applicants for the following:
(a) felony arrest in the last seven (7) years; (b) alcohol related arrest within the last five (5) years; (c) record of any military courts-martial convictions in the past ten (10) years; (d) illegal use of narcotics or other controlled substances possession in the past year, or illegal purchase, production, transfer, or distribution of narcotics or other controlled substances in the last seven (7) years; and (e) delinquency on any federal debts or bankruptcy in the last seven (7) years.
The Contractor shall make a written record of its pre-screening interview or review (including any information to mitigate the responses to items listed in (a) - (e)), and have the applicant verify the pre-screening record or review, sign and date it. Two (2) copies of the pre-screening signed record or review shall be supplied to the Division of Facilities and Security, Personnel Security Branch (DFS/PSB) with the Contractor employee's completed building access application package.
The Contractor shall further ensure that its employees, any subcontractor employees and consultants complete all building access security applications required by this clause within fourteen (14) calendar days of notification by DFS/PSB of initiation of the application process. Timely receipt of properly completed records of the Contractor's signed pre-screening record or review and building access security applications (submitted for candidates that have a reasonable probability of obtaining the level of access authorization necessary for access to NRC's facilities) is a contract requirement. Failure of the Contractor to comply with this contract administration requirement may be a basis to cancel the award, or terminate the contract for default, or offset from the contract's invoiced cost or price the NRC's incurred costs or delays as a result of inadequate pre-screening by the Contractor. In the event of cancellation or termination, the NRC may select another firm for contract award.
Page 54 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 A Contractor, subcontractor employee or consultant shall not have access to NRC facilities until he/she is approved by DFS/PSB. Temporary access may be approved based on a favorable NRC review and discretionary determination of their building access security forms. Final building access will be approved based on favorably adjudicated checks by the Government. However, temporary access approval will be revoked and the Contractor's employee may subsequently be denied access in the event the employee's investigation cannot be favorably determined by the NRC. Such employee will not be authorized to work under any NRC contract requiring building access without the approval of DFS/PSB. When an individual receives final access, the individual will be subject to a review or reinvestigation every five (5) or ten (10) years, depending on their job responsibilities at the NRC.
The Government shall have and exercise full and complete control and discretion over granting, denying, withholding, or terminating building access approvals for individuals performing work under this contract.
Individuals performing work under this contract at NRC facilities for a period of more than 30 calendar days shall be required to complete and submit to the Contractor representative an acceptable OPM Standard Form 85 (Questionnaire for Non-Sensitive Positions), and two (2) FD 258 (Fingerprint Charts). Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Employment Authorization Card, or other official documentation issued by the U.S. Citizenship and Immigration Services. Any applicant with less than five (5) years residency in the U.S. will not be approved for building access. The Contractor shall submit the documents to the NRC Contracting Officers Representative (COR) who will give them to DFS/PSB.
DFS/PSB may, among other things, grant or deny temporary unescorted building access approval to an individual based upon its review of the information contained in the OPM Standard Form 85 and the Contractor's pre-screening record. Also, in the exercise of its authority, the Government may, among other things, grant or deny permanent building access approval based on the results of its review or investigation.
This submittal requirement also applies to the officers of the firm who, for any reason, may visit the NRC work sites for an extended period of time during the term of the contract. In the event that DFS/PSB are unable to grant a temporary or permanent building access approval, to any individual performing work under this contract, the Contractor is responsible for assigning another individual to perform the necessary function without any delay in the contract's performance schedule, or without adverse impact to any other terms or conditions of the contract. The Contractor is responsible for informing those affected by this procedure of the required building access approval process (i.e., temporary and permanent determinations), and the possibility that individuals may be required to wait until permanent building access approvals are granted before beginning work in NRC's buildings.
CANCELLATION OR TERMINATION OF BUILDING ACCESS/ REQUEST The Contractor shall immediately notify the COR when a Contractor or subcontractor employee or consultant's need for NRC building access approval is withdrawn or the need by the Contractor employee's for building access terminates. The COR will immediately notify DFS/PSB (via e-mail) when a Contractor employee no longer requires building access. The Contractor shall be required to return any NRC issued badges to the COR for return to DFS/FSB (Facilities Security Branch) within three (3) days after their termination.
Page 55 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION I - Contract Clauses I.1 52.252-2 CLAUSES INCORPORATED BY REFERENCE. (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):
http://www.acquisition.gov/far/html/52 248 253.html#wp1120047 52.202-1 DEFINITIONS. (NOV 2013) 52.203-3 GRATUITIES. (APR 1984) 52.203-8 CANCELLATION, RESCISSION, AND RECOVERY OF FUNDS FOR ILLEGAL OR IMPROPER ACTIVITY. (MAY 2014) 52.203-10 PRICE OR FEE ADJUSTMENT FOR ILLEGAL OR IMPROPER ACTIVITY. (MAY 2014) 52.203-12 LIMITATION ON PAYMENTS TO INFLUENCE CERTAIN FEDERAL TRANSACTIONS. (OCT 2010) 52.203-17 CONTRACTOR EMPLOYEE WHISTLEBLOWER RIGHTS AND REQUIREMENT TO INFORM EMPLOYEES OF WHISTLEBLOWER RIGHTS. (APR 2014) 52.204-4 PRINTED OR COPIED DOUBLE-SIDED ON POSTCONSUMER FIBER CONTENT PAPER. (MAY 2011) 52.204-9 PERSONAL IDENTITY VERIFICATION OF CONTRACTOR PERSONNEL. (JAN 2011) 52.204-13 SYSTEM FOR AWARD MANAGEMENT MAINTENANCE. (JUL 2013) 52.207-3 RIGHT OF FIRST REFUSAL OF EMPLOYMENT. (MAY 2006) 52.215-8 ORDER OF PRECEDENCE - UNIFORM CONTRACT FORMAT. (OCT 1997) 52.215-23 LIMITATIONS ON PASS-THROUGH CHARGES. (OCT 2009) 52.216-31 TIME-AND-MATERIALS/LABOR-HOUR PROPOSAL REQUIREMENTS-COMMERCIAL ITEM ACQUISITION. (FEB 2007) 52.223-5 POLLUTION PREVENTION AND RIGHT-TO-KNOW INFORMATION. (MAY 2011) 52.223-6 DRUG-FREE WORKPLACE. (MAY 2001) 52.228-5 INSURANCE - WORK ON A GOVERNMENT INSTALLATION. (JAN 1997) 52.229-3 FEDERAL, STATE, AND LOCAL TAXES. (FEB 2013) 52.232-1 PAYMENTS. (APR 1984) 52.232-8 DISCOUNTS FOR PROMPT PAYMENT. (FEB 2002)
Page 56 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 52.232-11 EXTRAS. (APR 1984) 52.232-18 AVAILABILITY OF FUNDS. (APR 1984) 52.232-22 LIMITATION OF FUNDS. (APR 1984) 52.232-23 ASSIGNMENT OF CLAIMS. (MAY 2014) 52.232-33 PAYMENT BY ELECTRONIC FUNDS TRANSFER - SYSTEM FOR AWARD MANAGEMENT (JUL 2013) 52.233-1 DISPUTES. (MAY 2014) - ALTERNATE I (DEC 1991) 52.233-3 PROTEST AFTER AWARD. (AUG 1996) 52.233-4 APPLICABLE LAW FOR BREACH OF CONTRACT CLAIM. (OCT 2004) 52.237-2 PROTECTION OF GOVERNMENT BUILDINGS, EQUIPMENT, AND VEGETATION. (APR 1984) 52.237-3 CONTINUITY OF SERVICES. (JAN 1991) 52.242-1 NOTICE OF INTENT TO DISALLOW COSTS. (APR 1984) 52.242-3 PENALTIES FOR UNALLOWABLE COSTS. (MAY 2014) 52.243-3 CHANGES - TIME-AND-MATERIALS OR LABOR-HOURS. (SEP 2000) 52.244-6 SUBCONTRACTS FOR COMMERCIAL ITEMS. (FEB 2016) 52.246-25 LIMITATION OF LIABILITY - SERVICES. (FEB 1997) 52.249-1 TERMINATION FOR CONVENIENCE OF THE GOVERNMENT (FIXED-PRICE) (SHORT FORM).
(APR 1984) 52.249-2 TERMINATION FOR CONVENIENCE OF THE GOVERNMENT (FIXED-PRICE). (APR 2012) 52.249-4 TERMINATION FOR CONVENIENCE OF THE GOVERNMENT (SERVICES) (SHORT FORM).
(APR 1984) 52.249-14 EXCUSABLE DELAYS. (APR 1984)
I.2 52.204-1 APPROVAL OF CONTRACT (DEC 1989)
This contract is subject to the written approval of the Contracting Officer and shall not be binding until so approved.
I.3 52.212-4 CONTRACT TERMS AND CONDITIONS - COMMERCIAL ITEMS. (MAY 2015) -
ALTERNATE I (MAY 2014)
(a) Inspection/Acceptance. (1) The Government has the right to inspect and test all materials furnished and services performed under this contract, to the extent practicable at all places and times, including the period of performance, and in any event before acceptance. The Government may also inspect the Page 57 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 plant or plants of the Contractor or any subcontractor engaged in contract performance. The Government will perform inspections and tests in a manner that will not unduly delay the work.
(2) If the Government performs inspection or tests on the premises of the Contractor or a subcontractor, the Contractor shall furnish and shall require subcontractors to furnish all reasonable facilities and assistance for the safe and convenient performance of these duties.
(3) Unless otherwise specified in the contract, the Government will accept or reject services and materials at the place of delivery as promptly as practicable after delivery, and they will be presumed accepted 60 days after the date of delivery, unless accepted earlier.
(4) At any time during contract performance, but not later than 6 months (or such other time as may be specified in the contract) after acceptance of the services or materials last delivered under this contract, the Government may require the Contractor to replace or correct services or materials that at time of delivery failed to meet contract requirements. Except as otherwise specified in paragraph (a)(6) of this clause, the cost of replacement or correction shall be determined under paragraph (i) of this clause, but the "hourly rate" for labor hours incurred in the replacement or correction shall be reduced to exclude that portion of the rate attributable to profit. Unless otherwise specified below, the portion of the "hourly rate" attributable to profit shall be 10 percent. The Contractor shall not tender for acceptance materials and services required to be replaced or corrected without disclosing the former requirement for replacement or correction, and, when required, shall disclose the corrective action taken. [Insert portion of labor rate attributable to profit.]
(5)(i) If the Contractor fails to proceed with reasonable promptness to perform required replacement or correction, and if the replacement or correction can be performed within the ceiling price (or the ceiling price as increased by the Government), the Government may-(A) By contract or otherwise, perform the replacement or correction, charge to the Contractor any increased cost, or deduct such increased cost from any amounts paid or due under this contract; or (B) Terminate this contract for cause.
(ii) Failure to agree to the amount of increased cost to be charged to the Contractor shall be a dispute under the Disputes clause of the contract.
(6) Notwithstanding paragraphs (a)(4) and (5) above, the Government may at any time require the Contractor to remedy by correction or replacement, without cost to the Government, any failure by the Contractor to comply with the requirements of this contract, if the failure is due to-(i) Fraud, lack of good faith, or willful misconduct on the part of the Contractor's managerial personnel; or (ii) The conduct of one or more of the Contractor's employees selected or retained by the Contractor after any of the Contractor's managerial personnel has reasonable grounds to believe that the employee is habitually careless or unqualified.
(7) This clause applies in the same manner and to the same extent to corrected or replacement materials or services as to materials and services originally delivered under this contract.
(8) The Contractor has no obligation or liability under this contract to correct or replace materials Page 58 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 and services that at time of delivery do not meet contract requirements, except as provided in this clause or as may be otherwise specified in the contract.
(9) Unless otherwise specified in the contract, the Contractor's obligation to correct or replace Government-furnished property shall be governed by the clause pertaining to Government property.
(b) Assignment. The Contractor or its assignee may assign its rights to receive payment due as a result of performance of this contract to a bank, trust company, or other financing institution, including any Federal lending agency in accordance with the Assignment of Claims Act (31 U.S.C. 3727).
However, when a third party makes payment (e.g., use of the Governmentwide commercial purchase card), the Contractor may not assign its rights to receive payment under this contract.
(c) Changes. Changes in the terms and conditions of this contract may be made only by written agreement of the parties.
(d) Disputes. This contract is subject to 41 U.S.C. chapter 71, Contract Disputes. Failure of the parties to this contract to reach agreement on any request for equitable adjustment, claim, appeal or action arising under or relating to this contract shall be a dispute to be resolved in accordance with the clause at FAR 52.233-1, Disputes, which is incorporated herein by reference. The Contractor shall proceed diligently with performance of this contract, pending final resolution of any dispute arising under the contract.
(e) Definitions. (1) The clause at FAR 52.202-1, Definitions, is incorporated herein by reference. As used in this clause-(i) Direct materials means those materials that enter directly into the end product, or that are used or consumed directly in connection with the furnishing of the end product or service.
(ii) Hourly rate means the rate(s) prescribed in the contract for payment for labor that meets the labor category qualifications of a labor category specified in the contract that are-(A) Performed by the contractor; (B) Performed by the subcontractors; or (C) Transferred between divisions, subsidiaries, or affiliates of the contractor under a common control.
(iii) Materials means-(A) Direct materials, including supplies transferred between divisions, subsidiaries, or affiliates of the contractor under a common control; (B) Subcontracts for supplies and incidental services for which there is not a labor category specified in the contract; (C) Other direct costs (e.g., incidental services for which there is not a labor category specified in the contract, travel, computer usage charges, etc.);
Page 59 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (D) The following subcontracts for services which are specifically excluded from the hourly rate: [Insert any subcontracts for services to be excluded from the hourly rates prescribed in the schedule.]; and (E) Indirect costs specifically provided for in this clause.
(iv) Subcontract means any contract, as defined in FAR Subpart 2.1, entered into with a subcontractor to furnish supplies or services for performance of the prime contract or a subcontract including transfers between divisions, subsidiaries, or affiliates of a contractor or subcontractor. It includes, but is not limited to, purchase orders, and changes and modifications to purchase orders.
(f) Excusable delays. The Contractor shall be liable for default unless nonperformance is caused by an occurrence beyond the reasonable control of the Contractor and without its fault or negligence such as, acts of God or the public enemy, acts of the Government in either its sovereign or contractual capacity, fires, floods, epidemics, quarantine restrictions, strikes, unusually severe weather, and delays of common carriers. The Contractor shall notify the Contracting Officer in writing as soon as it is reasonably possible after the commencement of any excusable delay, setting forth the full particulars in connection therewith, shall remedy such occurrence with all reasonable dispatch, and shall promptly give written notice to the Contracting Officer of the cessation of such occurrence.
(g) Invoice. (1) The Contractor shall submit an original invoice and three copies (or electronic invoice, if authorized) to the address designated in the contract to receive invoices. An invoice must include-(i) Name and address of the Contractor; (ii) Invoice date and number; (iii) Contract number, contract line item number and, if applicable, the order number; (iv) Description, quantity, unit of measure, unit price and extended price of the items delivered; (v) Shipping number and date of shipment, including the bill of lading number and weight of shipment if shipped on Government bill of lading; (vi) Terms of any discount for prompt payment offered; (vii) Name and address of official to whom payment is to be sent; (viii) Name, title, and phone number of person to notify in event of defective invoice; and (ix) Taxpayer Identification Number (TIN). The Contractor shall include its TIN on the invoice only if required elsewhere in this contract.
(x) Electronic funds transfer (EFT) banking information.
(A) The Contractor shall include EFT banking information on the invoice only if required elsewhere in this contract.
(B) If EFT banking information is not required to be on the invoice, in order for the invoice to be a proper invoice, the Contractor shall have submitted correct EFT Page 60 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 banking information in accordance with the applicable solicitation provision, contract clause (e.g., 52.232-33, Payment by Electronic Funds Transfer-System for Award Management, or 52.232-34, Payment by Electronic Funds Transfer-Other Than System for Award Management), or applicable agency procedures.
(C) EFT banking information is not required if the Government waived the requirement to pay by EFT.
(2) Invoices will be handled in accordance with the Prompt Payment Act (31 U.S.C. 3903) and Office of Management and Budget (OMB) prompt payment regulations at 5 CFR part 1315.
(h) Patent indemnity. The Contractor shall indemnify the Government and its officers, employees and agents against liability, including costs, for actual or alleged direct or contributory infringement of, or inducement to infringe, any United States or foreign patent, trademark or copyright, arising out of the performance of this contract, provided the Contractor is reasonably notified of such claims and proceedings.
(i) Payments. (1) Work performed. The Government will pay the Contractor as follows upon the submission of commercial invoices approved by the Contracting Officer:
(i) Hourly rate.
(A) The amounts shall be computed by multiplying the appropriate hourly rates prescribed in the contract by the number of direct labor hours performed.
Fractional parts of an hour shall be payable on a prorated basis.
(B) The rates shall be paid for all labor performed on the contract that meets the labor qualifications specified in the contract. Labor hours incurred to perform tasks for which labor qualifications were specified in the contract will not be paid to the extent the work is performed by individuals that do not meet the qualifications specified in the contract, unless specifically authorized by the Contracting Officer.
(C) Invoices may be submitted once each month (or at more frequent intervals, if approved by the Contracting Officer) to the Contracting Officer or the authorized representative.
(D) When requested by the Contracting Officer or the authorized representative, the Contractor shall substantiate invoices (including any subcontractor hours reimbursed at the hourly rate in the schedule) by evidence of actual payment, individual daily job timecards, records that verify the employees meet the qualifications for the labor categories specified in the contract, or other substantiation specified in the contract.
(E) Unless the Schedule prescribes otherwise, the hourly rates in the Schedule shall not be varied by virtue of the Contractor having performed work on an overtime basis.
(1) If no overtime rates are provided in the Schedule and the Contracting Officer approves overtime work in advance, overtime rates shall be negotiated.
Page 61 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (2) Failure to agree upon these overtime rates shall be treated as a dispute under the Disputes clause of this contract.
(3) If the Schedule provides rates for overtime, the premium portion of those rates will be reimbursable only to the extent the overtime is approved by the Contracting Officer.
(ii) Materials.
(A) If the Contractor furnishes materials that meet the definition of a commercial item at 2.101, the price to be paid for such materials shall not exceed the Contractor's established catalog or market price, adjusted to reflect the-(1) Quantities being acquired; and (2) Any modifications necessary because of contract requirements.
(B) Except as provided for in paragraph (i)(1)(ii)(A) and (D)(2) of this clause, the Government will reimburse the Contractor the actual cost of materials (less any rebates, refunds, or discounts received by the contractor that are identifiable to the contract) provided the Contractor-(1) Has made payments for materials in accordance with the terms and conditions of the agreement or invoice; or (2) Makes these payments within 30 days of the submission of the Contractor's payment request to the Government and such payment is in accordance with the terms and conditions of the agreement or invoice.
(C) To the extent able, the Contractor shall-(1) Obtain materials at the most advantageous prices available with due regard to securing prompt delivery of satisfactory materials; and (2) Give credit to the Government for cash and trade discounts, rebates, scrap, commissions, and other amounts that are identifiable to the contract.
(D) Other Costs. Unless listed below, other direct and indirect costs will not be reimbursed.
(1) Other Direct Costs. The Government will reimburse the Contractor on the basis of actual cost for the following, provided such costs comply with the requirements in paragraph (i)(1)(ii)(B) of this clause: [Insert each element of other direct costs (e.g., travel, computer usage charges, etc.
Insert "None" if no reimbursement for other direct costs will be provided. If this is an indefinite delivery contract, the Contracting Officer may insert "Each order must list separately the elements of other direct charge(s) for that order or, if no reimbursement for other direct costs will be provided, insert 'None'".]
(2) Indirect Costs (Material Handling, Subcontract Administration, etc.).
Page 62 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 The Government will reimburse the Contractor for indirect costs on a pro-rata basis over the period of contract performance at the following fixed price: [Insert a fixed amount for the indirect costs and payment schedule.
Insert "$0" if no fixed price reimbursement for indirect costs will be provided. (If this is an indefinite delivery contract, the Contracting Officer may insert "Each order must list separately the fixed amount for the indirect costs and payment schedule or, if no reimbursement for indirect costs, insert 'None')."]
(2) Total cost. It is estimated that the total cost to the Government for the performance of this contract shall not exceed the ceiling price set forth in the Schedule and the Contractor agrees to use its best efforts to perform the work specified in the Schedule and all obligations under this contract within such ceiling price. If at any time the Contractor has reason to believe that the hourly rate payments and material costs that will accrue in performing this contract in the next succeeding 30 days, if added to all other payments and costs previously accrued, will exceed 85 percent of the ceiling price in the Schedule, the Contractor shall notify the Contracting Officer giving a revised estimate of the total price to the Government for performing this contract with supporting reasons and documentation. If at any time during the performance of this contract, the Contractor has reason to believe that the total price to the Government for performing this contract will be substantially greater or less than the then stated ceiling price, the Contractor shall so notify the Contracting Officer, giving a revised estimate of the total price for performing this contract, with supporting reasons and documentation. If at any time during performance of this contract, the Government has reason to believe that the work to be required in performing this contract will be substantially greater or less than the stated ceiling price, the Contracting Officer will so advise the Contractor, giving the then revised estimate of the total amount of effort to be required under the contract.
(3) Ceiling price. The Government will not be obligated to pay the Contractor any amount in excess of the ceiling price in the Schedule, and the Contractor shall not be obligated to continue performance if to do so would exceed the ceiling price set forth in the Schedule, unless and until the Contracting Officer notifies the Contractor in writing that the ceiling price has been increased and specifies in the notice a revised ceiling that shall constitute the ceiling price for performance under this contract. When and to the extent that the ceiling price set forth in the Schedule has been increased, any hours expended and material costs incurred by the Contractor in excess of the ceiling price before the increase shall be allowable to the same extent as if the hours expended and material costs had been incurred after the increase in the ceiling price.
(4) Access to records. At any time before final payment under this contract, the Contracting Officer (or authorized representative) will have access to the following (access shall be limited to the listing below unless otherwise agreed to by the Contractor and the Contracting Officer):
(i) Records that verify that the employees whose time has been included in any invoice meet the qualifications for the labor categories specified in the contract; (ii) For labor hours (including any subcontractor hours reimbursed at the hourly rate in the schedule), when timecards are required as substantiation for payment-(A) The original timecards (paper-based or electronic);
(B) The Contractor's timekeeping procedures; (C) Contractor records that show the distribution of labor between jobs or Page 63 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 contracts; and (D) Employees whose time has been included in any invoice for the purpose of verifying that these employees have worked the hours shown on the invoices.
(iii) For material and subcontract costs that are reimbursed on the basis of actual cost-(A) Any invoices or subcontract agreements substantiating material costs; and (B) Any documents supporting payment of those invoices.
(5) Overpayments/Underpayments. Each payment previously made shall be subject to reduction to the extent of amounts, on preceding invoices, that are found by the Contracting Officer not to have been properly payable and shall also be subject to reduction for overpayments or to increase for underpayments. The Contractor shall promptly pay any such reduction within 30 days unless the parties agree otherwise. The Government within 30 days will pay any such increases, unless the parties agree otherwise. The Contractor's payment will be made by check.
If the Contractor becomes aware of a duplicate invoice payment or that the Government has otherwise overpaid on an invoice payment, the Contractor shall-(i) Remit the overpayment amount to the payment office cited in the contract along with a description of the overpayment including the-(A) Circumstances of the overpayment (e.g., duplicate payment, erroneous payment, liquidation errors, date(s) of overpayment);
(B) Affected contract number and delivery order number, if applicable; (C) Affected contract line item or subline item, if applicable; and (D) Contractor point of contact.
(ii) Provide a copy of the remittance and supporting documentation to the Contracting Officer.
(6)(i) All amounts that become payable by the Contractor to the Government under this contract shall bear simple interest from the date due until paid unless paid within 30 days of becoming due. The interest rate shall be the interest rate established by the Secretary of the Treasury, as provided in 41 U.S.C. 7109, which is applicable to the period in which the amount becomes due, and then at the rate applicable for each six month period as established by the Secretary until the amount is paid.
(ii) The Government may issue a demand for payment to the Contractor upon finding a debt is due under the contract.
(iii) Final Decisions. The Contracting Officer will issue a final decision as required by 33.211 if-(A) The Contracting Officer and the Contractor are unable to reach agreement on the existence or amount of a debt in a timely manner; (B) The Contractor fails to liquidate a debt previously demanded by the Page 64 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Contracting Officer within the timeline specified in the demand for payment unless the amounts were not repaid because the Contractor has requested an installment payment agreement; or (C) The Contractor requests a deferment of collection on a debt previously demanded by the Contracting Officer (see FAR 32.607-2).
(iv) If a demand for payment was previously issued for the debt, the demand for payment included in the final decision shall identify the same due date as the original demand for payment.
(v) Amounts shall be due at the earliest of the following dates:
(A) The date fixed under this contract.
(B) The date of the first written demand for payment, including any demand for payment resulting from a default termination.
(vi) The interest charge shall be computed for the actual number of calendar days involved beginning on the due date and ending on-(A) The date on which the designated office receives payment from the Contractor; (B) The date of issuance of a Government check to the Contractor from which an amount otherwise payable has been withheld as a credit against the contract debt; or (C) The date on which an amount withheld and applied to the contract debt would otherwise have become payable to the Contractor.
(vii) The interest charge made under this clause may be reduced under the procedures prescribed in 32.608-2 of the Federal Acquisition Regulation in effect on the date of this contract.
(viii) Upon receipt and approval of the invoice designated by the Contractor as the "completion invoice" and supporting documentation, and upon compliance by the Contractor with all terms of this contract, any outstanding balances will be paid within 30 days unless the parties agree otherwise. The completion invoice, and supporting documentation, shall be submitted by the Contractor as promptly as practicable following completion of the work under this contract, but in no event later than 1 year (or such longer period as the Contracting Officer may approve in writing) from the date of completion.
(7) Release of claims. The Contractor, and each assignee under an assignment entered into under this contract and in effect at the time of final payment under this contract, shall execute and deliver, at the time of and as a condition precedent to final payment under this contract, a release discharging the Government, its officers, agents, and employees of and from all liabilities, obligations, and claims arising out of or under this contract, subject only to the following exceptions.
(i) Specified claims in stated amounts, or in estimated amounts if the amounts are not Page 65 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 susceptible to exact statement by the Contractor.
(ii) Claims, together with reasonable incidental expenses, based upon the liabilities of the Contractor to third parties arising out of performing this contract, that are not known to the Contractor on the date of the execution of the release, and of which the Contractor gives notice in writing to the Contracting Officer not more than 6 years after the date of the release or the date of any notice to the Contractor that the Government is prepared to make final payment, whichever is earlier.
(iii) Claims for reimbursement of costs (other than expenses of the Contractor by reason of its indemnification of the Government against patent liability), including reasonable incidental expenses, incurred by the Contractor under the terms of this contract relating to patents.
(8) Prompt payment. The Government will make payment in accordance with the Prompt Payment Act (31 U.S.C. 3903) and prompt payment regulations at 5 CFR part 1315.
(9) Electronic Funds Transfer (EFT). If the Government makes payment by EFT, see 52.212-5(b) for the appropriate EFT clause.
(10) Discount. In connection with any discount offered for early payment, time shall be computed from the date of the invoice. For the purpose of computing the discount earned, payment shall be considered to have been made on the date that appears on the payment check or the specified payment date if an electronic funds transfer payment is made.
(j) Risk of loss. Unless the contract specifically provides otherwise, risk of loss or damage to the supplies provided under this contract shall remain with the Contractor until, and shall pass to the Government upon:
(1) Delivery of the supplies to a carrier, if transportation is f.o.b. origin; or (2) Delivery of the supplies to the Government at the destination specified in the contract, if transportation is f.o.b. destination.
(k) Taxes. The contract price includes all applicable Federal, State, and local taxes and duties.
(l) Termination for the Government's convenience. The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. In the event of such termination, the Contractor shall immediately stop all work hereunder and shall immediately cause any and all of its suppliers and subcontractors to cease work. Subject to the terms of this contract, the Contractor shall be paid an amount for direct labor hours (as defined in the Schedule of the contract) determined by multiplying the number of direct labor hours expended before the effective date of termination by the hourly rate(s) in the contract, less any hourly rate payments already made to the Contractor plus reasonable charges the Contractor can demonstrate to the satisfaction of the Government using its standard record keeping system that have resulted from the termination. The Contractor shall not be required to comply with the cost accounting standards or contract cost principles for this purpose. This paragraph does not give the Government any right to audit the Contractor's records. The Contractor shall not be paid for any work performed or costs incurred that reasonably could have been avoided.
(m) Termination for cause. The Government may terminate this contract, or any part hereof, for cause in the event of any default by the Contractor, or if the Contractor fails to comply with any contract terms and conditions, or fails to provide the Government, upon written request, with adequate assurances of Page 66 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 future performance. Subject to the terms of this contract, the Contractor shall be paid an amount computed under paragraph (i) Payments of this clause, but the "hourly rate" for labor hours expended in furnishing work not delivered to or accepted by the Government shall be reduced to exclude that portion of the rate attributable to profit. Unless otherwise specified in paragraph (a)(4) of this clause, the portion of the "hourly rate" attributable to profit shall be 10 percent. In the event of termination for cause, the Contractor shall be liable to the Government for any and all rights and remedies provided by law. If it is determined that the Government improperly terminated this contract for default, such termination shall be deemed a termination for convenience.
(n) Title. Unless specified elsewhere in this contract, title to items furnished under this contract shall pass to the Government upon acceptance, regardless of when or where the Government takes physical possession.
(o) Warranty. The Contractor warrants and implies that the items delivered hereunder are merchantable and fit for use for the particular purpose described in this contract.
(p) Limitation of liability. Except as otherwise provided by an express warranty, the Contractor will not be liable to the Government for consequential damages resulting from any defect or deficiencies in accepted items.
(q) Other compliances. The Contractor shall comply with all applicable Federal, State and local laws, executive orders, rules and regulations applicable to its performance under this contract.
(r) Compliance with laws unique to Government contracts. The Contractor agrees to comply with 31 U.S.C. 1352 relating to limitations on the use of appropriated funds to influence certain Federal contracts; 18 U.S.C. 431 relating to officials not to benefit; 40 U.S.C. chapter 37, Contract Work Hours and Safety Standards; 41 U.S.C. chapter 87, Kickbacks; 41 U.S.C. 4712 and 10 U.S.C. 2409 relating to whistleblower protections; 49 U.S.C. 40118, Fly American; and 41 U.S.C. chapter 21 relating to procurement integrity.
(s) Order of precedence. Any inconsistencies in this solicitation or contract shall be resolved by giving precedence in the following order: (1) the schedule of supplies/services; (2) The Assignments, Disputes, Payments, Invoice, Other Compliances, Compliance with Laws Unique to Government Contracts, and Unauthorized Obligations paragraphs of this clause; (3) the clause at 52.212-5; (4) addenda to this solicitation or contract, including any license agreements for computer software; (5) solicitation provisions if this is a solicitation; (6) other paragraphs of this clause; (7) the Standard Form 1449; (8) other documents, exhibits, and attachments; and (9) the specification.
(t) System for Award Management (SAM) (1) Unless exempted by an addendum to this contract, the Contractor is responsible during performance and through final payment of any contract for the accuracy and completeness of the data within the SAM database, and for any liability resulting from the Government's reliance on inaccurate or incomplete data. To remain registered in the SAM database after the initial registration, the Contractor is required to review and update on an annual basis from the date of initial registration or subsequent updates its information in the SAM database to ensure it is current, accurate and complete. Updating information in the SAM does not alter the terms and conditions of this contract and is not a substitute for a properly executed contractual document.
(2)(i) If a Contractor has legally changed its business name, "doing business as" name, or division name (whichever is shown on the contract), or has transferred the assets used in performing the contract, but has not completed the necessary requirements regarding novation and change-of-name agreements in FAR subpart 42.12, the Contractor shall provide the responsible Contracting Officer a minimum of one business day's written notification of its Page 67 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 intention to (A) change the name in the SAM database; (B) comply with the requirements of subpart 42.12; and (C) agree in writing to the timeline and procedures specified by the responsible Contracting Officer. The Contractor must provide with the notification sufficient documentation to support the legally changed name.
(ii) If the Contractor fails to comply with the requirements of paragraph (t)(2)(i) of this clause, or fails to perform the agreement at paragraph (t)(2)(i)(C) of this clause, and, in the absence of a properly executed novation or change-of-name agreement, the SAM information that shows the Contractor to be other than the Contractor indicated in the contract will be considered to be incorrect information within the meaning of the "Suspension of Payment" paragraph of the electronic funds transfer (EFT) clause of this contract.
(3) The Contractor shall not change the name or address for EFT payments or manual payments, as appropriate, in the SAM record to reflect an assignee for the purpose of assignment of claims (see Subpart 32.8, Assignment of Claims). Assignees shall be separately registered in the SAM database. Information provided to the Contractor's SAM record that indicates payments, including those made by EFT, to an ultimate recipient other than that Contractor will be considered to be incorrect information within the meaning of the "Suspension of payment" paragraph of the EFT clause of this contract.
(4) Offerors and Contractors may obtain information on registration and annual confirmation requirements via SAM accessed through https://www.acquisition.gov.
(u) Unauthorized Obligations. (1) Except as stated in paragraph (u)(2) of this clause, when any supply or service acquired under this contract is subject to any End User License Agreement (EULA), Terms of Service (TOS), or similar legal instrument or agreement, that includes any clause requiring the Government to indemnify the Contractor or any person or entity for damages, costs, fees, or any other loss or liability that would create an Anti-Deficiency Act violation (31 U.S.C. 1341), the following shall govern:
(i) Any such clause is unenforceable against the Government.
(ii) Neither the Government nor any Government authorized end user shall be deemed to have agreed to such clause by virtue of it appearing in the EULA, TOS, or similar legal instrument or agreement. If the EULA, TOS, or similar legal instrument or agreement is invoked through an "I agree" click box or other comparable mechanism (e.g., "click-wrap" or "browse-wrap" agreements), execution does not bind the Government or any Government authorized end user to such clause.
(iii) Any such clause is deemed to be stricken from the EULA, TOS, or similar legal instrument or agreement.
(2) Paragraph (u)(1) of this clause does not apply to indemnification by the Government that is expressly authorized by statute and specifically authorized under applicable agency regulations and procedures.
(v) Incorporation by reference. The Contractor's representations and certifications, including those completed electronically via the System for Award Management (SAM), are incorporated by reference into the contract.
I.3 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR Page 68 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 EXECUTIVE ORDERS - COMMERCIAL ITEMS. (MAR 2016) - ALTERNATE II (MAR 2016)
(a) The Contractor shall comply with the following Federal Acquisition Regulation (FAR) clauses, which are incorporated in this contract by reference, to implement provisions of law or Executive orders applicable to acquisitions of commercial items:
(1) 52.209-10, Prohibition on Contracting with Inverted Domestic Corporations (NOV 2015).
(2) 52.233-3, Protest After Award (AUG 1996) (31 U.S.C. 3553).
(3) 52.233-4, Applicable Law for Breach of Contract Claim (OCT 2004) (Public Laws 108-77 and 108-78 (19 U.S.C. 3805 note)).
(b) The Contractor shall comply with the FAR clauses in this paragraph (b) that the Contracting Officer has indicated as being incorporated in this contract by reference to implement provisions of law or Executive orders applicable to acquisitions of commercial items: (Contracting Officer check as appropriate.)
[X] (1) 52.203-6, Restrictions on Subcontractor Sales to the Government (SEP 2006), with Alternate I (OCT 1995) (41 U.S.C. 4704 and 10 U.S.C. 2402).
[X] (2) 52.203-13, Contractor Code of Business Ethics and Conduct (OCT 2015) (41 U.S.C.
3509).
[] (3) 52.203-15, Whistleblower Protections under the American Recovery and Reinvestment Act of 2009 (JUN 2010) (Section 1553 of Pub. L. 111-5). (Applies to contracts funded by the American Recovery and Reinvestment Act of 2009.)
[X] (4) 52.204-10, Reporting Executive Compensation and First-Tier Subcontract Awards (OCT 2015) (Pub. L. 109-282) (31 U.S.C. 6101 note).
(5) (Reserved)
[X] (6) 52.204-14, Service Contract Reporting Requirements (JAN 2014) (Pub. L. 111-117, section 743 of Div. C).
[] (7) 52.204-15, Service Contract Reporting Requirements for Indefinite-Delivery Contracts (JAN 2014) (Pub. L. 111-117, section 743 of Div. C).
[X] (8) 52.209-6, Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment. (OCT 2015) (31 U.S.C. 6101 note).
[X] (9) 52.209-9, Updates of Publicly Available Information Regarding Responsibility Matters (JUL 2013) (41 U.S.C. 2313).
[] (10) (Reserved)
[] (11)(i) 52.219-3, Notice of HUBZone Set-Aside or Sole-Source Award (NOV 2011) (15 U.S.C.
657a).
[] (ii) Alternate I (NOV 2011) of 52.219-3.
Page 69 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
[] (12)(i) 52.219-4, Notice of Price Evaluation Preference for HUBZone Small Business Concerns (OCT 2014) (if the offeror elects to waive the preference, it shall so indicate in its offer) (15 U.S.C. 657a).
[] (ii) Alternate I (JAN 2011) of 52.219-4.
[] (13) (Reserved)
[] (14)(i) 52.219-6, Notice of Total Small Business Set-Aside (NOV 2011) (15 U.S.C. 644).
[] (ii) Alternate I (NOV 2011).
[] (iii) Alternate II (NOV 2011).
[] (15)(i) 52.219-7, Notice of Partial Small Business Set-Aside (JUN 2003) (15 U.S.C. 644).
[] (ii) Alternate I (OCT 1995) of 52.219-7.
[] (iii) Alternate II (MAR 2004) of 52.219-7.
[X] (16) 52.219-8, Utilization of Small Business Concerns (OCT 2014) (15 U.S.C. 637(d)(2) and (3)).
[X] (17)(i) 52.219-9, Small Business Subcontracting Plan (OCT 2015) (15 U.S.C. 637(d)(4)).
[] (ii) Alternate I (OCT 2001) of 52.219-9.
[X] (iii) Alternate II (OCT 2001) of 52.219-9.
[] (iv) Alternate III (OCT 2015) of 52.219-9.
[] (18) 52.219-13, Notice of Set-Aside of Orders (NOV 2011) (15 U.S.C. 644(r)).
[] (19) 52.219-14, Limitations on Subcontracting (NOV 2011) (15 U.S.C. 637(a)(14)).
[X] (20) 52.219-16, Liquidated Damages-Subcontracting Plan (JAN 1999) (15 U.S.C.
637(d)(4)(F)(i)).
[] (21) 52.219-27, Notice of Service-Disabled Veteran-Owned Small Business Set-Aside (NOV 2011) (15 U.S.C. 657f).
[X] (22) 52.219-28, Post Award Small Business Program Rerepresentation (JUL 2013) (15 U.S.C. 632(a)(2)).
[] (23) 52.219-29, Notice of Set-Aside for, or Sole Source Award to, Economically Disadvantaged Women-Owned Small Business Concerns (DEC 2015) (15 U.S.C. 637(m)).
[] (24) 52.219-30, Notice of Set-Aside for, or Sole Source Award to, Women-Owned Small Business Concerns Eligible Under the Women-Owned Small Business Program (DEC 2015) (15 U.S.C. 637(m)).
[] (25) 52.222-3, Convict Labor (JUN 2003) (E.O. 11755).
Page 70 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
[] (26) 52.222-19, Child Labor-Cooperation with Authorities and Remedies (FEB 2016) (E.O.
13126).
[] (27) 52.222-21, Prohibition of Segregated Facilities (APR 2015).
[X] (28) 52.222-26, Equal Opportunity (APR 2015) (E.O. 11246).
[X] (29) 52.222-35, Equal Opportunity for Veterans (OCT 2015) (38 U.S.C. 4212).
[X] (30) 52.222-36, Equal Opportunity for Workers with Disabilities (JUL 2014) (29 U.S.C. 793).
[X] (31) 52.222-37, Employment Reports on Veterans (FEB 2016) (38 U.S.C. 4212).
[] (32) 52.222-40, Notification of Employee Rights Under the National Labor Relations Act (DEC 2010) (E.O. 13496).
[X] (33)(i) 52.222-50, Combating Trafficking in Persons (MAR 2015) (22 U.S.C. chapter 78 and E.O. 13627).
[] (ii) Alternate I (MAR 2015) of 52.222-50 (22 U.S.C. chapter 78 and E.O. 13627).
[] (34) 52.222-54, Employment Eligibility Verification (OCT 2015). (E. O. 12989). (Not applicable to the acquisition of commercially available off-the-shelf items or certain other types of commercial items as prescribed in 22.1803.)
[] (35)(i) 52.223-9, Estimate of Percentage of Recovered Material Content for EPA-Designated Items (MAY 2008) (42 U.S.C. 6962(c)(3)(A)(ii)). (Not applicable to the acquisition of commercially available off-the-shelf items.)
[] (ii) Alternate I (MAY 2008) of 52.223-9 (42 U.S.C. 6962(i)(2)(C)). (Not applicable to the acquisition of commercially available off-the-shelf items.)
[] (36)(i) 52.223-13, Acquisition of EPEAT-Registered Imaging Equipment (JUN 2014) (E.O.s 13423 and 13514).
[] (ii) Alternate I (OCT 2015) of 52.223-13.
[] (37)(i) 52.223-14, Acquisition of EPEAT-Registered Televisions (JUN 2014) (E.O.s 13423 and 13514).
(ii) Alternate I (JUN 2014) of 52.223-14.
[] (38) 52.223-15, Energy Efficiency in Energy-Consuming Products (DEC 2007) (42 U.S.C.
8259b).
[] (39)(i) 52.223-16, Acquisition of EPEAT-Registered Personal Computer Products (OCT 2015) (E.O.s 13423 and 13514).
[](ii) Alternate I (JUN 2014) of 52.223-16.
[X] (40) 52.223-18, Encouraging Contractor Policies to Ban Text Messaging While Driving (AUG Page 71 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 2011)
[] (41) 52.225-1, Buy American-Supplies (MAY 2014) (41 U.S.C. chapter 83).
[] (42)(i) 52.225-3, Buy American-Free Trade Agreements-Israeli Trade Act (MAY 2014) (41 U.S.C. chapter 83, 19 U.S.C. 3301 note, 19 U.S.C. 2112 note, 19 U.S.C. 3805 note, 19 U.S.C.
4001 note, Pub. L. 103-182, 108-77, 108-78, 108-286, 108-302, 109-53, 109-169, 109-283, 110-138, 112-41, 112-42, and 112-43.
[] (ii) Alternate I (MAY 2014) of 52.225-3.
[] (iii) Alternate II (MAY 2014) of 52.225-3.
[] (iv) Alternate III (MAY 2014) of 52.225-3.
[] (43) 52.225-5, Trade Agreements (FEB 2016) (19 U.S.C. 2501, et seq., 19 U.S.C. 3301 note).
[X] (44) 52.225-13, Restrictions on Certain Foreign Purchases (JUN 2008) (E.O.'s, proclamations, and statutes administered by the Office of Foreign Assets Control of the Department of the Treasury).
[] (45) 52.225-26, Contractors Performing Private Security Functions Outside the United States (JUL 2013) (Section 862, as amended, of the National Defense Authorization Act for Fiscal Year 2008; 10 U.S.C. 2302 Note).
[] (46) 52.226-4, Notice of Disaster or Emergency Area Set-Aside (NOV 2007) (42 U.S.C. 5150).
[] (47) 52.226-5, Restrictions on Subcontracting Outside Disaster or Emergency Area (NOV 2007) (42 U.S.C. 5150).
[] (48) 52.232-29, Terms for Financing of Purchases of Commercial Items (FEB 2002) (41 U.S.C. 4505, 10 U.S.C. 2307(f)).
[] (49) 52.232-30, Installment Payments for Commercial Items (OCT 1995) (41 U.S.C. 4505, 10 U.S.C. 2307(f)).
[X] (50) 52.232-33, Payment by Electronic Funds Transfer-System for Award Management (JUL 2013) (31 U.S.C. 3332).
[] (51) 52.232-34, Payment by Electronic Funds Transfer - Other than System for Award Management (JUL 2013) (31 U.S.C. 3332).
[] (52) 52.232-36, Payment by Third Party (MAY 2014) (31 U.S.C. 3332).
[] (53) 52.239-1, Privacy or Security Safeguards (AUG 1996) (5 U.S.C. 552a).
[] (54)(i) 52.247-64, Preference for Privately Owned U.S.-Flag Commercial Vessels (FEB 2006)
(46 U.S.C. Appx. 1241(b) and 10 U.S.C. 2631).
[] (ii) Alternate I (APR 2003) of 52.247-64.
(c) The Contractor shall comply with the FAR clauses in this paragraph (c), applicable to commercial Page 72 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 services, that the Contracting Officer has indicated as being incorporated in this contract by reference to implement provisions of law or Executive orders applicable to acquisitions of commercial items:
(Contracting Officer check as appropriate.)
[X] (1) 52.222-17, Nondisplacement of Qualified Workers (MAY 2014) (E.O. 13495).
[] (2) 52.222-41, Service Contract Labor Standards (MAY 2014) (41 U.S.C. chapter 67).
[] (3) 52.222-42, Statement of Equivalent Rates for Federal Hires (MAY 2014) (29 U.S.C. 206 and 41 U.S.C. chapter 67).
[] (4) 52.222-43, Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (Multiple Year and Option Contracts) (MAY 2014) (29 U.S.C. 206 and 41 U.S.C.
chapter 67).
[] (5) 52.222-44, Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (MAY 2014) (29 U.S.C 206 and 41 U.S.C. chapter 67).
[] (6) 52.222-51, Exemption from Application of the Service Contract Labor Standards to Contracts for Maintenance, Calibration, or Repair of Certain Equipment-Requirements (MAY 2014) (41 U.S.C. chapter 67).
[] (7) 52.222-53, Exemption from Application of the Service Contract Labor Standards to Contracts for Certain Services-Requirements (MAY 2014) (41 U.S.C. chapter 67).
[] (8) 52.222-55, Minimum Wages Under Executive Order 13658 (MAR 2016).
[] (9) 52.226-6, Promoting Excess Food Donation to Nonprofit Organizations (MAY 2014) (42 U.S.C. 1792).
[] (10) 52.237-11, Accepting and Dispensing of $1 Coin (SEP 2008) (31 U.S.C. 5112(p)(1)).
(d)(1) The Comptroller General of the United States, an appropriate Inspector General appointed under section 3 or 8G of the Inspector General Act of 1978 (5 U.S.C. App.), or an authorized representative of either of the foregoing officials shall have access to and right to-(i) Examine any of the Contractor's or any subcontractors' records that pertain to, and involve transactions relating to, this contract; and (ii) Interview any officer or employee regarding such transactions.
(e)(1) Notwithstanding the requirements of the clauses in paragraphs (a), (b), and (c), of this clause, the Contractor is not required to flow down any FAR clause in a subcontract for commercial items, other than-(i) Paragraph (d) of this clause. This paragraph flows down to all subcontracts, except the authority of the Inspector General under paragraph (d)(1)(ii) does not flow down; and (ii) Those clauses listed in this paragraph (e)(1). Unless otherwise indicated below, the extent of the flow down shall be as required by the clause-(A) 52.203-13, Contractor Code of Business Ethics and Conduct (OCT 2015) (41 Page 73 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 U.S.C. 3509).
(B) 52.203-15, Whistleblower Protections Under the American Recovery and Reinvestment Act of 2009 (JUN 2010) (Section 1553 of Pub. L. 111-5).
(C) 52.219-8, Utilization of Small Business Concerns (OCT 2014) (15 U.S.C.
637(d)(2) and (3)), in all subcontracts that offer further subcontracting opportunities. If the subcontract (except subcontracts to small business concerns) exceeds $700,000 ($1.5 million for construction of any public facility),
the subcontractor must include 52.219-8 in lower tier subcontracts that offer subcontracting opportunities.
(D) 52.222-21, Prohibition of Segregated Facilities (APR 2015).
(E) 52.222-26, Equal Opportunity (APR 2015) (E.O. 11246).
(F) 52.222-35, Equal Opportunity for Veterans (OCT 2015) (38 U.S.C. 4212).
(G) 52.222-36, Equal Opportunity for Workers with Disabilities (JUL 2014) (29 U.S.C. 793).
(H) 52.222-40, Notification of Employee Rights Under the National Labor Relations Act (DEC 2010) (E.O. 13496). Flow down required in accordance with paragraph (f) of FAR clause 52.222-40.
(I) 52.222-41, Service Contract Labor Standards (MAY 2014) (41 U.S.C. chapter 67).
(J) __ (1) 52.222-50, Combating Trafficking in Persons (MAR 2015) (22 U.S.C.
chapter 78 and E.O. 13627).
__ (2) Alternate I (MAR 2015) of 52.222-50 (22 U.S.C. chapter 78 and E.O. 13627).
(K) 52.222-51, Exemption from Application of the Service Contract Labor Standards to Contracts for Maintenance, Calibration, or Repair of Certain Equipment-Requirements (MAY 2014) (41 U.S.C. chapter 67).
(L) 52.222-53, Exemption from Application of the Service Contract Labor Standards to Contracts for Certain Services-Requirements (MAY 2014) (41 U.S.C. chapter 67).
(M) 52.222-54, Employment Eligibility Verification (OCT 2015) (Executive Order 12989).
(N) 52.222-55, Minimum Wages Under Executive Order 13658 (MAR 2016).
(O) 52.226-6, Promoting Excess Food Donation to Nonprofit Organizations.
(MAY 2014) (42 U.S.C. 1792). Flow down required in accordance with paragraph (e) of FAR clause 52.226-6.
(P) 52.247-64, Preference for Privately Owned U.S.-Flag Commercial Vessels Page 74 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (FEB 2006) (46 U.S.C. Appx. 1241(b) and 10 U.S.C. 2631). Flow down required in accordance with paragraph (d) of FAR clause 52.247-64.
I.4 52.217-8 OPTION TO EXTEND SERVICES. (NOV 1999)
The Government may require continued performance of any services within the limits and at the rates specified in the contract. These rates may be adjusted only as a result of revisions to prevailing labor rates provided by the Secretary of Labor. The option provision may be exercised more than once, but the total extension of performance hereunder shall not exceed 6 months. The Contracting Officer may exercise the option by written notice to the Contractor within 30 days.
I.5 52.217-9 OPTION TO EXTEND THE TERM OF THE CONTRACT. (MAR 2000)
(a) The Government may extend the term of this contract by written notice to the Contractor within 30 days; provided that the Government gives the Contractor a preliminary written notice of its intent to extend at least 30 days before the contract expires. The preliminary notice does not commit the Government to an extension.
(b) If the Government exercises this option, the extended contract shall be considered to include this option clause.
(c) The total duration of this contract, including the exercise of any options under this clause, shall not exceed 5 years.
I.6 52.219-28 POST-AWARD SMALL BUSINESS PROGRAM REREPRESENTATION. (JUL 2013)
(a) Definitions. As used in this clause-Long-term contract means a contract of more than five years in duration, including options. However, the term does not include contracts that exceed five years in duration because the period of performance has been extended for a cumulative period not to exceed six months under the clause at 52.217-8, Option to Extend Services, or other appropriate authority.
Small business concern means a concern, including its affiliates, that is independently owned and operated, not dominant in the field of operation in which it is bidding on Government contracts, and qualified as a small business under the criteria in 13 CFR part 121 and the size standard in paragraph (c) of this clause. Such a concern is "not dominant in its field of operation" when it does not exercise a controlling or major influence on a national basis in a kind of business activity in which a number of business concerns are primarily engaged. In determining whether dominance exists, consideration shall be given to all appropriate factors, including volume of business, number of employees, financial resources, competitive status or position, ownership or control of materials, processes, patents, license agreements, facilities, sales territory, and nature of business activity.
(b) If the Contractor represented that it was a small business concern prior to award of this contract, the Contractor shall rerepresent its size status according to paragraph (e) of this clause or, if applicable, paragraph (g) of this clause, upon the occurrence of any of the following:
(1) Within 30 days after execution of a novation agreement or within 30 days after modification of the contract to include this clause, if the novation agreement was executed prior to inclusion Page 75 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 of this clause in the contract.
(2) Within 30 days after a merger or acquisition that does not require a novation or within 30 days after modification of the contract to include this clause, if the merger or acquisition occurred prior to inclusion of this clause in the contract.
(3) For long-term contracts-(i) Within 60 to 120 days prior to the end of the fifth year of the contract; and (ii) Within 60 to 120 days prior to the date specified in the contract for exercising any option thereafter.
(c) The Contractor shall rerepresent its size status in accordance with the size standard in effect at the time of this rerepresentation that corresponds to the North American Industry Classification System (NAICS) code assigned to this contract. The small business size standard corresponding to this NAICS code can be found at http://www.sba.gov/content/table-small-business-size-standards.
(d) The small business size standard for a Contractor providing a product which it does not manufacture itself, for a contract other than a construction or service contract, is 500 employees.
(e) Except as provided in paragraph (g) of this clause, the Contractor shall make the representation required by paragraph (b) of this clause by validating or updating all its representations in the Reprensentations and Certifications section of the System for Award Management (SAM) and its other data in SAM, as necessary, to ensure that they reflect the Contractor's current status. The Contractor shall notify the contracting office in writing within the timeframes specified in paragraph (b) of this clause that the data have been validated or updated, and provide the date of the validation or update.
(f) If the Contractor represented that it was other than a small business concern prior to award of this contract, the Contractor may, but is not required to, take the actions required by paragraphs (e) or (g) of this clause.
(g) If the Contractor does not have representations and certifications in SAM, or does not have a representation in SAM for the NAICS code applicable to this contract, the Contractor is required to complete the following rerepresentation and submit it to the contracting office, along with the contract number and the date on which the rerepresentation was completed:
The Contractor represents that it _X_ is, __ is not a small business concern under NAICS Code 541513 assigned to contract number GS00F003X/ NRC-HQ-84-16-T-0001.
I.7 52.222-26 EQUAL OPPORTUNITY. (APR 2015) - ALTERNATE I (FEB 1999)
Notice. The following terms of this clause are waived for this contract: [Contracting Officer shall list terms].
(a) Definitions. As used in this clause-Gender identity has the meaning given by the Department of Labor's Office of Federal Contract Compliance Programs, and is found at www.dol.gov/ofccp/LGBT/LGBT_FAQs.html.
Sexual orientation has the meaning given by the Department of Labor's Office of Federal Contract Compliance Programs, and is found at www.dol.gov/ofccp/LGBT/LGBT_FAQs.html.
Page 76 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 United States means the 50 States, the District of Columbia, Puerto Rico, the Northern Mariana Islands, American Samoa, Guam, the U.S. Virgin Islands, and Wake Island.
(b)(1) If, during any 12-month period (including the 12 months preceding the award of this contract),
the Contractor has been or is awarded nonexempt Federal contracts and/or subcontracts that have an aggregate value in excess of $10,000, the Contractor shall comply with this clause, except for work performed outside the United States by employees who were not recruited within the United States.
Upon request, the Contractor shall provide information necessary to determine the applicability of this clause.
(2) If the Contractor is a religious corporation, association, educational institution, or society, the requirements of this clause do not apply with respect to the employment of individuals of a particular religion to perform work connected with the carrying on of the Contractor's activities (41 CFR 60-1.5).
(c)(1) The Contractor shall not discriminate against any employee or applicant for employment because of race, color, religion, sex, sexual orientation, gender identity, or national origin. However, it shall not be a violation of this clause for the Contractor to extend a publicly announced preference in employment to Indians living on or near an Indian reservation, in connection with employment opportunities on or near an Indian reservation, as permitted by 41 CFR 60-1.5.
(2) The Contractor shall take affirmative action to ensure that applicants are employed, and that employees are treated during employment, without regard to their race, color, religion, sex, sexual orientation, gender identity, or national origin. This shall include, but not be limited to, (i) employment, (ii) upgrading, (iii) demotion, (iv) transfer, (v) recruitment or recruitment advertising, (vi) layoff or termination, (vii) rates of pay or other forms of compensation, and (viii) selection for training, including apprenticeship.
(3) The Contractor shall post in conspicuous places available to employees and applicants for employment the notices to be provided by the Contracting Officer that explain this clause.
(4) The Contractor shall, in all solicitations or advertisements for employees placed by or on behalf of the Contractor, state that all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, or national origin.
(5) The Contractor shall send, to each labor union or representative of workers with which it has a collective bargaining agreement or other contract or understanding, the notice to be provided by the Contracting Officer advising the labor union or workers' representative of the Contractor's commitments under this clause, and post copies of the notice in conspicuous places available to employees and applicants for employment.
(6) The Contractor shall comply with Executive Order 11246, as amended, and the rules, regulations, and orders of the Secretary of Labor.
(7) The Contractor shall furnish to the contracting agency all information required by Executive Order 11246, as amended, and by the rules, regulations, and orders of the Secretary of Labor.
The Contractor shall also file Standard Form 100 (EEO-1), or any successor form, as prescribed in 41 CFR part 60-1. Unless the Contractor has filed within the 12 months preceding the date of contract award, the Contractor shall, within 30 days after contract award, apply to either the regional Office of Federal Contract Compliance Programs (OFCCP) or the local office of the Page 77 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Equal Employment Opportunity Commission for the necessary forms.
(8) The Contractor shall permit access to its premises, during normal business hours, by the contracting agency or the OFCCP for the purpose of conducting on-site compliance evaluations and complaint investigations. The Contractor shall permit the Government to inspect and copy any books, accounts, records (including computerized records), and other material that may be relevant to the matter under investigation and pertinent to compliance with Executive Order 11246, as amended, and rules and regulations that implement the Executive Order.
(9) If the OFCCP determines that the Contractor is not in compliance with this clause or any rule, regulation, or order of the Secretary of Labor, this contract may be canceled, terminated, or suspended in whole or in part and the Contractor may be declared ineligible for further Government contracts, under the procedures authorized in Executive Order 11246, as amended. In addition, sanctions may be imposed and remedies invoked against the Contractor as provided in Executive Order 11246, as amended; in the rules, regulations, and orders of the Secretary of Labor; or as otherwise provided by law.
(10) The Contractor shall include the terms and conditions of this clause in every subcontract or purchase order that is not exempted by the rules, regulations, or orders of the Secretary of Labor issued under Executive Order 11246, as amended, so that these terms and conditions will be binding upon each subcontractor or vendor.
(11) The Contractor shall take such action with respect to any subcontract or purchase order as the contracting officer may direct as a means of enforcing these terms and conditions, including sanctions for noncompliance; provided, that if the Contractor becomes involved in, or is threatened with, litigation with a subcontractor or vendor as a result of any direction, the Contractor may request the United States to enter into the litigation to protect the interests of the United States.
(d) Notwithstanding any other clause in this contract, disputes relative to this clause will be governed by the procedures in 41 CFR 60-1.1.
I.8 52.222-35 EQUAL OPPORTUNITY FOR VETERANS. (OCT 2015)
(a) Definitions. As used in this clause-
"Active duty wartime or campaign badge veteran," "Armed Forces service medal veteran," "disabled veteran," "protected veteran," "qualified disabled veteran," and "recently separated veteran" have the meanings given at FAR 22.1301.
(b) Equal opportunity clause. The Contractor shall abide by the requirements of the equal opportunity clause at 41 CFR 60-300.5(a), as of March 24, 2014. This clause prohibits discrimination against qualified protected veterans, and requires affirmative action by the Contractor to employ and advance in employment qualified protected veterans.
(c) Subcontracts. The Contractor shall insert the terms of this clause in subcontracts of $150,000 or more unless exempted by rules, regulations, or orders of the Secretary of Labor. The Contractor shall act as specified by the Director, Office of Federal Contract Compliance Programs, to enforce the terms, including action for noncompliance. Such necessary changes in language may be made as shall be appropriate to identify properly the parties and their undertakings.
Page 78 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 I.9 52.222-36 EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES. (JUL 2014)
(a) Equal opportunity clause. The Contractor shall abide by the requirements of the equal opportunity clause at 41 CFR 60-741.5(a), as of March 24, 2014. This clause prohibits discrimination against qualified individuals on the basis of disability, and requires affirmative action by the Contractor to employ and advance in employment qualified individuals with disabilities.
(b) Subcontracts. The Contractor shall include the terms of this clause in every subcontract or purchase order in excess of $15,000 unless exempted by rules, regulations, or orders of the Secretary, so that such provisions will be binding upon each subcontractor or vendor. The Contractor shall act as specified by the Director, Office of Federal Contract Compliance Programs of the U.S. Department of Labor, to enforce the terms, including action for noncompliance. Such necessary changes in language may be made as shall be appropriate to identify properly the parties and their undertakings.
I.10 52.232-7 PAYMENTS UNDER TIME-AND-MATERIALS AND LABOR-HOUR CONTRACTS. (AUG 2012)
The Government will pay the Contractor as follows upon the submission of vouchers approved by the Contracting Officer or the authorized representative:
(a) Hourly rate. (1) Hourly rate means the rate(s) prescribed in the contract for payment for labor that meets the labor category qualifications of a labor category specified in the contract that are-(i) Performed by the Contractor; (ii) Performed by the subcontractors; or (iii) Transferred between divisions, subsidiaries, or affiliates of the Contractor under a common control.
(2) The amounts shall be computed by multiplying the appropriate hourly rates prescribed in the Schedule by the number of direct labor hours performed.
(3) The hourly rates shall be paid for all labor performed on the contract that meets the labor qualifications specified in the contract. Labor hours incurred to perform tasks for which labor qualifications were specified in the contract will not be paid to the extent the work is performed by employees that do not meet the qualifications specified in the contract, unless specifically authorized by the Contracting Officer.
(4) The hourly rates shall include wages, indirect costs, general and administrative expense, and profit. Fractional parts of an hour shall be payable on a prorated basis.
(5) Vouchers may be submitted not more than once every two weeks, to the Contracting Officer or authorized representative. A small business concern may receive more frequent payments than every two weeks. The Contractor shall substantiate vouchers (including any subcontractor hours reimbursed at the hourly rate in the schedule) by evidence of actual payment and by-(i) Individual daily job timekeeping records; Page 79 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (ii) Records that verify the employees meet the qualifications for the labor categories specified in the contract; or (iii) Other substantiation approved by the Contracting Officer.
(6) Promptly after receipt of each substantiated voucher, the Government shall, except as otherwise provided in this contract, and subject to the terms of paragraph (e) of this clause, pay the voucher as approved by the Contracting Officer or authorized representative.
(7) Unless otherwise prescribed in the Schedule, the Contracting Officer may unilaterally issue a contract modification requiring the Contractor to withhold amounts from its billings until a reserve is set aside in an amount that the Contracting Officer considers necessary to protect the Government's interests. The Contracting Officer may require a withhold of 5 percent of the amounts due under paragraph (a) of this clause, but the total amount withheld for the contract shall not exceed $50,000. The amounts withheld shall be retained until the Contractor executes and delivers the release required by paragraph (g) of this clause.
(8) Unless the Schedule prescribes otherwise, the hourly rates in the Schedule shall not be varied by virtue of the Contractor having performed work on an overtime basis. If no overtime rates are provided in the Schedule and overtime work is approved in advance by the Contracting Officer, overtime rates shall be negotiated. Failure to agree upon these overtime rates shall be treated as a dispute under the Disputes clause of this contract. If the Schedule provides rates for overtime, the premium portion of those rates will be reimbursable only to the extent the overtime is approved by the Contracting Officer.
(b) Materials. (1) For the purposes of this clause-(i) Direct materials means those materials that enter directly into the end product, or that are used or consumed directly in connection with the furnishing of the end product or service.
(ii) Materials means-(A) Direct materials, including supplies transferred between divisions, subsidiaries, or affiliates of the Contractor under a common control; (B) Subcontracts for supplies and incidental services for which there is not a labor category specified in the contract; (C) Other direct costs (e.g., incidental services for which there is not a labor category specified in the contract, travel, computer usage charges, etc.); and (D) Applicable indirect costs.
(2) If the Contractor furnishes its own materials that meet the definition of a commercial item at 2.101, the price to be paid for such materials shall not exceed the Contractor's established catalog or market price, adjusted to reflect the-(i) Quantities being acquired; and (ii) Actual cost of any modifications necessary because of contract requirements.
Page 80 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (3) Except as provided for in paragraph (b)(2) of this clause, the Government will reimburse the Contractor for allowable cost of materials provided the Contractor-(i) Has made payments for materials in accordance with the terms and conditions of the agreement or invoice; or (ii) Ordinarily makes these payments within 30 days of the submission of the Contractor's payment request to the Government and such payment is in accordance with the terms and conditions of the agreement or invoice.
(4) Payment for materials is subject to the Allowable Cost and Payment clause of this contract.
The Contracting Officer will determine allowable costs of materials in accordance with Subpart 31.2 of the Federal Acquisition Regulation (FAR) in effect on the date of this contract.
(5) The Contractor may include allocable indirect costs and other direct costs to the extent they are-(i) Comprised only of costs that are clearly excluded from the hourly rate; (ii) Allocated in accordance with the Contractor's written or established accounting practices; and (iii) Indirect costs are not applied to subcontracts that are paid at the hourly rates.
(6) To the extent able, the Contractor shall-(i) Obtain materials at the most advantageous prices available with due regard to securing prompt delivery of satisfactory materials; and (ii) Take all cash and trade discounts, rebates, allowances, credits, salvage, commissions, and other benefits. When unable to take advantage of the benefits, the Contractor shall promptly notify the Contracting Officer and give the reasons. The Contractor shall give credit to the Government for cash and trade discounts, rebates, scrap, commissions, and other amounts that have accrued to the benefit of the Contractor, or would have accrued except for the fault or neglect of the Contractor. The Contractor shall not deduct from gross costs the benefits lost without fault or neglect on the part of the Contractor, or lost through fault of the Government.
(7) Except as provided for in 31.205-26(e) and (f), the Government will not pay profit or fee to the prime Contractor on materials.
(c) If the Contractor enters into any subcontract that requires consent under the clause at 52.244-2, Subcontracts, without obtaining such consent, the Government is not required to reimburse the Contractor for any costs incurred under the subcontract prior to the date the Contractor obtains the required consent. Any reimbursement of subcontract costs incurred prior to the date the consent was obtained shall be at the sole discretion of the Government.
(d) Total cost. It is estimated that the total cost to the Government for the performance of this contract shall not exceed the ceiling price set forth in the Schedule, and the Contractor agrees to use its best efforts to perform the work specified in the Schedule and all obligations under this contract within such ceiling price. If at any time the Contractor has reason to believe that the hourly rate payments and material costs that will accrue in performing this contract in the next succeeding 30 days, if added to all Page 81 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 other payments and costs previously accrued, will exceed 85 percent of the ceiling price in the Schedule, the Contractor shall notify the Contracting Officer giving a revised estimate of the total price to the Government for performing this contract with supporting reasons and documentation. If at any time during performing this contract, the Contractor has reason to believe that the total price to the Government for performing this contract will be substantially greater or less than the then stated ceiling price, the Contractor shall so notify the Contracting Officer, giving a revised estimate of the total price for performing this contract, with supporting reasons and documentation. If at any time during performing this contract, the Government has reason to believe that the work to be required in performing this contract will be substantially greater or less than the stated ceiling price, the Contracting Officer will so advise the Contractor, giving the then revised estimate of the total amount of effort to be required under the contract.
(e) Ceiling price. The Government will not be obligated to pay the Contractor any amount in excess of the ceiling price in the Schedule, and the Contractor shall not be obligated to continue performance if to do so would exceed the ceiling price set forth in the Schedule, unless and until the Contracting Officer notifies the Contractor in writing that the ceiling price has been increased and specifies in the notice a revised ceiling that shall constitute the ceiling price for performance under this contract. When and to the extent that the ceiling price set forth in the Schedule has been increased, any hours expended and material costs incurred by the Contractor in excess of the ceiling price before the increase shall be allowable to the same extent as if the hours expended and material costs had been incurred after the increase in the ceiling price.
(f) Audit. At any time before final payment under this contract, the Contracting Officer may request audit of the vouchers and supporting documentation. Each payment previously made shall be subject to reduction to the extent of amounts, on preceding vouchers, that are found by the Contracting Officer or authorized representative not to have been properly payable and shall also be subject to reduction for overpayments or to increase for underpayments. Upon receipt and approval of the voucher designated by the Contractor as the "completion voucher" and supporting documentation, and upon compliance by the Contractor with all terms of this contract (including, without limitation, terms relating to patents and the terms of paragraph (g) of this clause), the Government shall promptly pay any balance due the Contractor. The completion voucher, and supporting documentation, shall be submitted by the Contractor as promptly as practicable following completion of the work under this contract, but in no event later than 120 days (or such longer period as the Contracting Officer may approve in writing) from the date of completion.
(g) Assignment and Release of Claims. The Contractor, and each assignee under an assignment entered into under this contract and in effect at the time of final payment under this contract, shall execute and deliver, at the time of and as a condition precedent to final payment under this contract, a release discharging the Government, its officers, agents, and employees of and from all liabilities, obligations, and claims arising out of or under this contract, subject only to the following exceptions:
(1) Specified claims in stated amounts, or in estimated amounts if the amounts are not susceptible of exact statement by the Contractor.
(2) Claims, together with reasonable incidental expenses, based upon the liabilities of the Contractor to third parties arising out of performing this contract, that are not known to the Contractor on the date of the execution of the release, and of which the Contractor gives notice in writing to the Contracting Officer not more than 6 years after the date of the release or the date of any notice to the Contractor that the Government is prepared to make final payment, whichever is earlier.
(3) Claims for reimbursement of costs (other than expenses of the Contractor by reason of its Page 82 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 indemnification of the Government against patent liability), including reasonable incidental expenses, incurred by the Contractor under the terms of this contract relating to patents.
(h) Interim payments on contracts for other than services. (1) Interim payments made prior to the final payment under the contract are contract financing payments. Contract financing payments are not subject to the interest penalty provisions of the Prompt Payment Act.
(2) The designated payment office will make interim payments for contract financing on the
[Contracting Officer insert day as prescribed by agency head; if not prescribed, insert "30th"]
day after the designated billing office receives a proper payment request. In the event that the Government requires an audit or other review of a specific payment request to ensure compliance with the terms and conditions of the contract, the designated payment office is not compelled to make payment by the specified due date.
(i) Interim payments on contracts for services. For interim payments made prior to the final payment under this contract, the Government will make payment in accordance with the Prompt Payment Act (31 U.S.C. 3903) and prompt payment regulations at 5 CFR part 1315.
I.11 52.232-39 UNENFORCEABILITY OF UNAUTHORIZED OBLIGATIONS. (JUN 2013)
(a) Except as stated in paragraph (b) of this clause, when any supply or service acquired under this contract is subject to any End User License Agreement (EULA), Terms of Service (TOS), or similar legal instrument or agreement, that includes any clause requiring the Government to indemnify the Contractor or any person or entity for damages, costs, fees, or any other loss or liability that would create an Anti-Deficiency Act violation (31 U.S.C. 1341), the following shall govern:
(1) Any such clause is unenforceable against the Government.
(2) Neither the Government nor any Government authorized end user shall be deemed to have agreed to such clause by virtue of it appearing in the EULA, TOS, or similar legal instrument or agreement. If the EULA, TOS, or similar legal instrument or agreement is invoked through an "I agree" click box or other comparable mechanism (e.g., "click-wrap" or "browse-wrap" agreements), execution does not bind the Government or any Government authorized end user to such clause.
(3) Any such clause is deemed to be stricken from the EULA, TOS, or similar legal instrument or agreement.
(b) Paragraph (a) of this clause does not apply to indemnification by the Government that is expressly authorized by statute and specifically authorized under applicable agency regulations and procedures.
I.12 52.244-2 SUBCONTRACTS. (OCT 2010)
(a) Definitions. As used in this clause-
"Approved purchasing system" means a Contractor's purchasing system that has been reviewed and approved in accordance with Part 44 of the Federal Acquisition Regulation (FAR).
"Consent to subcontract" means the Contracting Officer's written consent for the Contractor to enter into a particular subcontract.
"Subcontract" means any contract, as defined in FAR Subpart 2.1, entered into by a subcontractor to furnish supplies or services for performance of the prime contract or a subcontract. It includes, but is not limited to, purchase orders, and changes and modifications to purchase orders.
Page 83 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 (b) When this clause is included in a fixed-price type contract, consent to subcontract is required only on unpriced contract actions (including unpriced modifications or unpriced delivery orders), and only if required in accordance with paragraph (c) or (d) of this clause.
(c) If the Contractor does not have an approved purchasing system, consent to subcontract is required for any subcontract that-(1) Is of the cost-reimbursement, time-and-materials, or labor-hour type; or (2) Is fixed-price and exceeds-(i) For a contract awarded by the Department of Defense, the Coast Guard, or the National Aeronautics and Space Administration, the greater of the simplified acquisition threshold or 5 percent of the total estimated cost of the contract; or (ii) For a contract awarded by a civilian agency other than the Coast Guard and the National Aeronautics and Space Administration, either the simplified acquisition threshold or 5 percent of the total estimated cost of the contract.
(d) If the Contractor has an approved purchasing system, the Contractor nevertheless shall obtain the Contracting Officer's written consent before placing the following subcontracts: []
(e)(1) The Contractor shall notify the Contracting Officer reasonably in advance of placing any subcontract or modification thereof for which consent is required under paragraph (b), (c) or (d) of this clause, including the following information:
(i) A description of the supplies or services to be subcontracted.
(ii) Identification of the type of subcontract to be used.
(iii) Identification of the proposed subcontractor.
(iv) The proposed subcontract price.
(v) The subcontractor's current, complete, and accurate certified cost or pricing data and Certificate of Current Cost or Pricing Data, if required by other contract provisions.
(vi) The subcontractor's Disclosure Statement or Certificate relating to Cost Accounting Standards when such data are required by other provisions of this contract.
(vii) A negotiation memorandum reflecting-(A) The principal elements of the subcontract price negotiations; (B) The most significant considerations controlling establishment of initial or revised prices; (C) The reason certified cost or pricing data were or were not required; (D) The extent, if any, to which the Contractor did not rely on the subcontractor's certified cost or pricing data in determining the price objective and in negotiating Page 84 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 the final price; (E) The extent to which it was recognized in the negotiation that the subcontractor's certified cost or pricing data were not accurate, complete, or current; the action taken by the Contractor and the subcontractor; and the effect of any such defective data on the total price negotiated; (F) The reasons for any significant difference between the Contractor's price objective and the price negotiated; and (G) A complete explanation of the incentive fee or profit plan when incentives are used. The explanation shall identify each critical performance element, management decisions used to quantify each incentive element, reasons for the incentives, and a summary of all trade-off possibilities considered.
(2) The Contractor is not required to notify the Contracting Officer in advance of entering into any subcontract for which consent is not required under paragraph (b), (c) or (d) of this clause.
(f) Unless the consent or approval specifically provides otherwise, neither consent by the Contracting Officer to any subcontract nor approval of the Contractor's purchasing system shall constitute a determination-(1) Of the acceptability of any subcontract terms or conditions; (2) Of the allowability of any cost under this contract; or (3) To relieve the Contractor of any responsibility for performing this contract.
(g) No subcontract or modification thereof placed under this contract shall provide for payment on a cost-plus-a-percentage-of-cost basis, and any fee payable under cost-reimbursement type subcontracts shall not exceed the fee limitations in FAR 15.404-4(c)(4)(i).
(h) The Contractor shall give the Contracting Officer immediate written notice of any action or suit filed and prompt notice of any claim made against the Contractor by any subcontractor or vendor that, in the opinion of the Contractor, may result in litigation related in any way to this contract, with respect to which the Contractor may be entitled to reimbursement from the Government.
(i) The Government reserves the right to review the Contractor's purchasing system as set forth in FAR Subpart 44.3.
(j) Paragraphs (c) and (e) of this clause do not apply to the following subcontracts, which were evaluated during negotiations: []
I.13 NRCI020 COMPLIANCE WITH SECTION 508 OF THE REHABILITATION ACT OF 1973, AS 89AMENDED (SEP 2013)
In 1998, Congress amended the Rehabilitation Act of 1973 (29 U.S.C. §794d) as amended by the Workforce Investment Act of 1998 (P.L. 105 - 220), August 7, 1998 to require Federal agencies to make their electronic and information technology (EIT) accessible to people with disabilities. Inaccessible technology interferes with an ability to obtain and use information quickly and easily. Section 508 was enacted to eliminate barriers in information technology, open new opportunities for people with disabilities, and encourage development of technologies that will help achieve these goals. The law applies to all Federal agencies when they develop, Page 85 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 procure, maintain, or use electronic and information technology. Under Section 508 (29 U.S.C. §794d),
agencies must give disabled employees and members of the public access to information that is comparable to access available to others.
Specifically, Section 508 of that Act requires that when Federal agencies develop, procure, maintain, or use EIT, Federal employees with disabilities have access to and use of information and data that is comparable to the access and use by Federal employees who are not individuals with disabilities, unless an undue burden would be imposed on the agency. (36 C.F.R. §1194 implements Section 508 of the Rehabilitation Act of 1973, as amended, and is viewable at: http://www.access-board.gov/sec508/standards.htm)
Exceptions.
All EIT that the government acquires by purchase or by lease/rental under this contract must meet the applicable accessibility standards at 36 C.F.R. Part 1194, unless one or more of the following exceptions at FAR 39.204 applies to this acquisition (applicable if checked):
[ ] The EIT is for a national security system.
[ ] The EIT is acquired by a contractor incidental to a contract.
[ ] The EIT is located in spaces frequented only by service personnel for maintenance, repair or occasional monitoring of equipment.
[ ] Compliance with the applicable 36 C.F.R. Part 1194 provisions would impose an undue burden on the agency.
Applicable Standards.
The following accessibility standards from 36 C.F.R. Part 1194 have been determined to be applicable to this contract/order. See www.section508.gov for more information:
[ ] 1194.21 Software applications and operating systems.
[ ] 1194.22 Web-based intranet and internet information and applications. 16 rules.
[ ] 1194.23 Telecommunications products.
[ ] 1194.24 Video and multimedia products.
[ ] 1194.25 Self contained, closed products.
[ ] 1194.26 Desktop and portable computers.
[ ] 1194.31 Functional performance criteria.
Page 86 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
[ ] 1194.41 Information, documentation, and support.
Note: Under the Exceptions paragraph, the Contracting Officer should check the boxes for any exceptions that apply. If no exceptions apply, then the Contracting Officer should, under the Applicable Standards paragraph, check the boxes that indicate which of the standards apply. See FAR Subpart 39.2 and www.section508.gov for additional guidance.
Page 87 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 SECTION J - List of Documents, Exhibits and Other Attachments ATTACHMENT 1 - Billing Instructions - Time-and-Materials/ Labor-Hour Type Contracts ATTACHMENT 2 - NRC Form 187 - Contract Security and/or Classification Requirements Page 88 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 INVOICE FORMAT FOR LH AND TM Version Control Date: January 26, 2015 ATTACHMENT 1 BILLING INSTRUCTIONS FOR TIME-AND-MATERIALS/LABOR-HOUR TYPE CONTRACTS (JAN 2015)
General: During performance and through final payment of this contract, the contractor is responsible for the accuracy and completeness of data within the System for Award Management (SAM) database and for any liability resulting from the Governments reliance on inaccurate or incomplete SAM data.
The contractor shall prepare invoices/vouchers for reimbursement of costs in the manner and format described herein. FAILURE TO SUBMIT INVOICES/VOUCHERS IN ACCORDANCE WITH THESE INSTRUCTIONS WILL RESULT IN REJECTION OF THE INVOICE/VOUCHER AS IMPROPER.
Standard Forms: Claims shall be submitted on the payee's letterhead, invoice/voucher, or on the Government's Standard Form 1034, "Public Voucher for Purchases and Services Other than Personal," and Standard Form 1035, "Public Voucher for Purchases Other than Personal--Continuation Sheet."
Electronic Invoice/Voucher Submissions: The preferred method of submitting vouchers/invoices is electronically to the U.S. Nuclear Regulatory Commission, via email to: NRCPayments@nrc.gov.
Hard-Copy Invoice/Voucher Submissions: If you submit a hard-copy of the invoice/voucher, a signed original and supporting documentation shall be submitted to the following address:
NRC Payments U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mailstop O3-E17A Rockville, MD 20852-2738 Purchase of Capital Property: ($50,000 or more with life of one year or longer)
Contractors must report to the Contracting Officer, electronically, any capital property acquired with contract funds having an initial cost of $50,000 or more, in accordance with procedures set forth in NRC Management Directive (MD).
Agency Payment Office: Payment will continue to be made by the office designated in the contract in Block 12 of the Standard Form 26, or Block 25 of the Standard Form 33, whichever is applicable.
Frequency: The contractor shall submit claims for reimbursement once each month, unless otherwise authorized by the Contracting Officer.
Format: Invoices/Vouchers shall be submitted in the format depicted on the attached sample form entitled "Invoice/Voucher for Purchases and Services Other Than Personal". Alternate formats are permissible only if they address all requirements of the Billing Instructions. The instructions for preparation and itemization of the invoice/voucher are included with the sample form.
Page 89 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 Task Order Contracts: The contractor must submit a separate invoice/voucher for each individual task order with detailed cost information. This includes all applicable cost elements and other items discussed in paragraphs (a) through (q) of the attached instructions. In addition, the invoice/voucher must specify the contract number, and the NRC-assigned task/delivery order number.
Billing of Costs after Expiration of Contract: If costs are incurred during the contract period and claimed after the contract has expired, you must cite the period during which these costs were incurred. To be considered a proper expiration invoice/voucher, the contractor shall clearly mark it "EXPIRATION INVOICE" or EXPIRATION VOUCHER".
Final invoices/vouchers shall be marked "FINAL INVOICE" or "FINAL VOUCHER".
Currency: Invoices/Vouchers must be expressed in U.S. Dollars.
Supersession: These instructions supersede previous Billing Instructions for Time-and-Materials/Labor-Hour Type Contracts (MAY 2013).
Page 90 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 INVOICE/VOUCHER FOR PURCHASES AND SERVICES OTHER THAN PERSONAL (SAMPLE FORMAT - COVER SHEET)
- 1. Official Agency Billing Office NRC Payments U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mailstop O3-E17A Rockville, MD 20852-2738
- 2. Invoice/Voucher Information
- a. Payee's DUNS Number or DUNS+4. The Payee shall include the Payees Data Universal Number (DUNS) or DUNS+4 number that identifies the Payees name and address. The DUNS+4 number is the DUNS number plus a 4-character suffix that may be assigned at the discretion of the Payee to identify alternative Electronic Funds Transfer (EFT) accounts for the same parent concern.
- b. Payees Name and Address. Show the name of the Payee as it appears in the contract and its correct address. Where the Payee is authorized to assign the proceeds of this contract in accordance with the clause at Federal Acquisition Regulation (FAR) 52.232-23 Assignment of Claims, the Payee shall require as a condition of any such assignment, that the assignee shall register separately in the System for Award Management (SAM) database at http://sam.gov and shall be paid by EFT in accordance with the terms of this contract. See FAR 52.232-33 Payment by Electronic Funds Transfer-System for Award Management.
- c. Taxpayer Identification Number. The Payee shall include the Payees taxpayer identification number (TIN) used by the Internal Revenue Service (IRS) in the administration of tax laws. (See IRS Web site:
http://www.irs.gov/Individuals/International-Taxpayers/Taxpayer-Identification-Numbers-(TIN)).
- d. Contract Number. Insert the NRC contract number (including Enterprise-wide Contract (EWC)), GSA Federal Supply Schedule (FSS), Governmentwide Agency Contract (GWAC) number, or Multiple Agency Contract (MAC) number, as applicable.
- e. Task Order Number. Insert the task/delivery order number (If Applicable). Do not include more than one task order per invoice or the invoice may be rejected as improper.
- f. Invoice/Voucher. The appropriate sequential number of the invoice/voucher, beginning with 001 should be designated. Contractors may also include an individual internal accounting number, if desired, in addition to the 3-digit sequential number.
- g. Date of Invoice/Voucher. Insert the date the invoice/voucher is prepared.
- h. Billing period. Insert the beginning and ending dates (day, month, year) of the period during which costs were incurred and for which reimbursement is requested.
- i. Labor Hours Expended. Provide a general summary description of the services performed and associated labor hours utilized during the invoice period. Specify the Contract Line Item Number (CLIN) or SubCLIN, as applicable, and information pertaining to the contracts labor categories/positions, and corresponding authorized hours.
Page 91 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- j. Property. For contractor acquired property, list each item with an initial acquisition cost of $50,000 or more and provide: (1) an item description, (2) manufacturer, (3) model number, (4) serial number, (5) acquisition cost, (6) date of purchase, and (7) a copy of the purchasing document.
- k. Shipping. Insert weight and zone of shipment, if shipped by parcel post.
- l. Charges for freight or express shipments. Attach prepaid bill if shipped by freight or express.
- m. Instructions. Include instructions to consignee to notify the Contracting Officer of receipt of shipment.
- n. For Indefinite Delivery contracts, the final invoice/voucher shall be marked "FINAL INVOICE" or "FINAL VOUCHER".
- o. Direct Costs. Insert the amount billed for the following cost elements, adjustments, suspensions, and total amounts, for both the current billing period and for the cumulative period (from contract inception to end date of this billing period).
(1) Direct (Burdened) Labor. This consists of salaries and wages paid (or accrued) for direct performance of the contract itemized, including a burden (or load) for indirect costs (i.e., fringe, overhead, General and Administrative, as applicable), and profit component, as follows:
Labor Hours Burdened Cumulative Category Billed Hourly Rate Total Hours Billed (2) Contractor-acquired property ($50,000 or more). List each item costing $50,000 or more and having a life expectancy of more than one year. List only those items of equipment for which reimbursement is requested. For each such item, list the following (as applicable): (a) an item description, (b) manufacturer, (c) model number, (d) serial number, (e) acquisition cost, (f) date of purchase, and (g) a copy of the purchasing document.
(3) Contractor-acquired property (under $50,000), Materials, and Supplies. These are equipment other than that described in (2) above, plus consumable materials and supplies. List by category.
List items valued at $1,000 or more separately. Provide the item number for each piece of equipment valued at $1,000 or more.
(4) Materials Handling Fee. Indirect costs allocated to direct materials in accordance the contractors usual accounting procedures.
(5) Consultant Fee. The supporting information must include the name, hourly or daily rate of the consultant, and reference the NRC approval (if not specifically approved in the original contract).
(6) Travel. Total costs associated with each trip must be shown in the following format:
Start Date Destination Costs From To From To $
(Must include separate detailed costs for airfare, per diem, and other transportation expenses. All costs must be adequately supported by copies of receipts or other documentation.)
(7) Subcontracts. Include separate detailed breakdown of all costs paid to approved Page 92 of 99
GS00F003X/ NRC-HQ-84-16-T-0001 subcontractors during the billing period.
- p. Total Amount Billed. Insert columns for total amounts for the current and cumulative periods.
- q. Adjustments. Insert columns for any adjustments, including outstanding suspensions for unsupported or unauthorized hours or costs, for the current and cumulative periods.
- r. Grand Totals.
Page 93 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- 3. Sample Invoice/Voucher Information Sample Invoice/Voucher Information (Supporting Documentation must be attached)
This invoice/voucher represents reimbursable costs for the billing period from through .
Amount Billed Current Period Cumulative (a)
Direct Costs (1) Direct burdened labor $_________ $_________
(2) Government property ($50,000 or more) $_________ $_________
(3) Government property, Materials, and Supplies (under $50,000 per item) $_________ $_________
(4) Materials Handling Fee $_________ $_________
(5) Consultants Fee $_________ $_________
(6) Travel $_________ $_________
(7) Subcontracts $_________ $_________
Total Direct Costs: $_________ $_________
(b) Total Amount Billed $_________ $_________
(c) Adjustments (+/-) $_________ $_________
(d) Grand Total $_________ $_________
(The invoice/voucher format provided above must include information similar to that included below in the following to ensure accuracy and completeness.)
SAMPLE SUPPORTING INFORMATION The budget information provided below is for format purposes only and is illustrative.
Cost Elements:
- 1) Direct Burdened Labor - $4,800 Labor Hours Burdened Cumulative Category Billed Rate Total Hours Billed Senior Engineer I 100 $28.00 $2,800 975 Engineer 50 $20.00 $1,000 465 Computer Analyst 100 $10.00 $1,000 320
$4,800 1,760 hrs.
Burdened labor rates must come directly from the contract.
- 2) Government-furnished and contractor-acquired property ($50,000 or more) - $60,000 Prototype Spectrometer - item number 1000-01 = $60,000 Page 94 of 99
GS00F003X/ NRC-HQ-84-16-T-0001
- 3) Government-furnished and contractor-acquired property (under $50,000), Materials, and Supplies - $2,000 10 Radon tubes @ $110.00 = $1,100 6 Pairs Electrostatic gloves @ $150.00 = $ 900
$2,000
- 4) Materials Handling Fee - $40 (2% of $2,000 in item #3)
- 5) Consultants' Fee - $100 Dr. Carney - 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> fully-burdened @ $100 = $100
- 6) Travel - $2,640 (i) Airfare: (2 Roundtrip trips for 1 person @ $300 per r/t ticket)
Start Date End Date Days From To Cost 4/1/2011 4/7/2011 7 Philadelphia, PA Wash, D.C. $300 7/1/2011 7/8/2011 8 Philadelphia, PA Wash, D.C. $300 (ii) Per Diem: $136/day x 15 days = $2,040
- 7) Subcontracting - $30,000 Company A = $10,000 Company B = $20,000
$30,000 (EX: Subcontracts for Companies A & B were consented to by the Contracting Officer by letter dated 6/15/2011.)
Total Amount Billed $99,580 Adjustments (+/-) - 0 Grand Total $99,580
- 4. Definitions Material handling costs. When included as part of material costs, material handling costs shall include only costs clearly excluded from the labor-hour rate. Material handling costs may include all appropriate indirect costs allocated to direct materials in accordance with the contractor's usual accounting procedures.
Page 95 of 99
Page 96 of 99
Page 98 of 99