Letter Sequence Draft Approval |
|---|
|
|
MONTHYEARPMNS20201348, Closed December 16, 2020 POST-SUBMITTAL Meeting to Discuss the Review of Holtec Topical Report HI-2200750, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology2020-12-0202 December 2020 Closed December 16, 2020 POST-SUBMITTAL Meeting to Discuss the Review of Holtec Topical Report HI-2200750, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Request ML20329A3682020-12-0303 December 2020 Completeness Determination Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Other ML20329A3602020-12-0404 December 2020 Email Proprietary Information Withholding Determination Form Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Other ML20329A3642020-12-0404 December 2020 Form Proprietary Information Withholding Determination Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Other ML20329A3732020-12-0404 December 2020 E-mail Completeness Determination Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Other ML21028A6382021-02-0202 February 2021 Summary of Closed Follow-up Call to Discuss U.S. Nuclear Regulatory Commission Review of HDI Topical Report HI-2200750, Rev.0, Holtec Spent Fuel Pool Heat Up Calculation Methodology and Initial Draft RAIs Project stage: Draft Approval ML21028A6452021-02-0202 February 2021 Summary of the Closed December 16, 2020 Post-Submittal Meeting to Discuss the Review of Holtec Topical Report Hi-2200750, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Meeting PMNS20211039, Closed Call Between U.S. Nuclear Regulatory Commission and Holtec Decommissioning International to Discuss Responses to the Requests for Additional Information for Hi-2200750, Rev. 0, Holtec Spent Fuel Pool Heat Up Calculation Methodolo2021-08-0505 August 2021 Closed Call Between U.S. Nuclear Regulatory Commission and Holtec Decommissioning International to Discuss Responses to the Requests for Additional Information for Hi-2200750, Rev. 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: RAI ML21228A2622021-08-16016 August 2021 Revised Response to Request for Additional Information - Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Response to RAI ML21239A3622021-09-0707 September 2021 Proprietary Information Withholding Determination Forms Revised Responses to Requests for Additional Information for HDI Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: RAI ML21239A3472021-09-0707 September 2021 Proprietary Information Withholding Determination Form Responses to Requests for Additional Information for HDI Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: RAI ML21238A0212021-09-10010 September 2021 1Summary of Closed Call to Discuss Revised Responses to Requests for Additional Information for the U.S. Nuclear Regulatory Commission Review of Holtec Decommissioning International Topical Report HI-2200750, Rev 0, Holtec Spent Fuel Pool Project stage: RAI ML21291A1612021-10-18018 October 2021 Response to Request for Additional Information 10 - Holtec Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Response to RAI ML21313A3852021-12-20020 December 2021 Email Formal Transmittal of the U.S. NRC Draft Safety Evaluation for Holtec International Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Draft Approval ML22006A3622022-01-0606 January 2022 Submittal of Us NRC Draft Safety Evaluation by the Office of Nuclear Reactor Regulation for the Topical Report HI-2200750, Rev. 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Identifying Information Proprietary to Holtec Internat Project stage: Draft Other ML22046A3182022-02-15015 February 2022 Submittal of Redacted U.S. Nuclear Regulatory Commission Draft Safety Evaluation by the Office of Nuclear Reactor Regulation for the Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Draft Other ML22075A3082022-03-25025 March 2022 Non-Proprietary Enclosure 1 U.S. NRC Final Safety Evaluation for Holtec International Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Approval ML22075A3632022-03-25025 March 2022 Proprietary Information Withholding Determination Form 897 for Holtec Prop Markup on the Draft SE HI-2200750 Rev 0 Spent Fuel Pool Heat Up Calculation Methodology Topical Report Project stage: Draft Approval ML22069B0882022-03-30030 March 2022 Email Formal Transmittal of the U.S. NRC Final Safety Evaluation for Holtec International Topical Report HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Approval ML22182A4182022-06-30030 June 2022 Decommissioning International, Submittal of Topical Report HI-2200750 -A Version Project stage: Other ML22346A1872022-12-21021 December 2022 International, Submittal of Topical Report HI-2200750 -A Version Project stage: Other ML23103A0622023-04-19019 April 2023 NRC 897 Form for the U.S. Nuclear Regulatory Commission Proprietary Withholding Determination for HI-2200750-A, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Other ML23103A0682023-04-20020 April 2023 NRC 896 Form for the U.S. Nuclear Regulatory Commission -A Verification of the HI-2200750-A, Rev 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Other ML23103A0672023-04-20020 April 2023 Transmittal Email of the Proprietary Withholding Determination for the Accepted Version of the Holtec International Topical Report HI-2200750-A, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology Project stage: Other 2021-09-10
[Table View] |
Text
From:
Lenning, Ekaterina To:
Andrea Sterdis
Subject:
Transmittal Email for the U.S. Nuclear Regulatory Commission Draft Safety Evaluation Topical Report (TR) HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology.
Date:
Monday, December 20, 2021 8:15:00 AM
- Andrea, By letter dated September 29, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20280A524), Holtec International (HI) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review the Topical Report (TR) HI-2200750 Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology. Based on its review of the information submitted in the TR, the NRC staff finds the TR is acceptable for referencing subject to the limitations specified in the TR, and in the NRC safety evaluation (SE).
A copy of the draft SE has been placed in the box.com folder. Andrea Sterdis, Holtec Decommissioning International, HI, has been given access to the folder. The draft SE is being provided for a proprietary information review. If HI provides comments on other areas, the NRC staff will exercise its discretion on whether to address those comments.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have determined that the draft SE may contain proprietary information. If you believe that any information in the draft SE is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Use bold brackets and yellow highlight to identify any [proprietary information]. After 10 working days, the draft SE will be made publicly available, if appropriate.
Your response must be via a letter from an authorized individual. In addition, please provide an electronic redline/strikeout Word version of the SE either via email or the box.com folder. It helps expedite the NRC staff response to comments if HI provides in the formal transmittal and in a separate Word file, a table with the following columns: Comment No., PageNo., and Line No., Comment Type (if comments other than proprietary information are provided (i.e.,clarity, accuracy)), Suggested Revision, and a blank column NRC Disposition. However, HI may provide its comments in any format it chooses. The final SE will be issued after making any necessary changes.
Note that at this stage of the process, the NRC staff has completed its review of the submitted information and will not entertain technical arguments. The staff conclusions and conditions will not change unless new information is provided that was not available during our review. If HI would like to discuss the draft SE in detail, we can do that in a noticed meeting that can be closed if proprietary information will be discussed.
Draft SE has been placed in ADAMS. The draft SE was made an Official Agency Record and declared as nonpublic because it may contain proprietary information. This email will be placed into ADAMS, made an Official Agency Record and declared public.
If you have any questions, please feel free to contact me at 301-415-3151 or by email at Ekaterina.Lenning@nrc.gov.
Ekaterina Lenning, Project Manager
Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission
Docket No.: 99902086