ML21028A645

From kanterella
Jump to navigation Jump to search

Summary of the Closed December 16, 2020 Post-Submittal Meeting to Discuss the Review of Holtec Topical Report Hi-2200750, Revision 0, Holtec Spent Fuel Pool Heat Up Calculation Methodology
ML21028A645
Person / Time
Site: 99902086
Issue date: 02/02/2021
From: Lenning K
Licensing Processes Branch
To: Dennis Morey
Licensing Processes Branch
Lenning K
Shared Package
ML21028A621 List:
References
EPID L-2020-TOP-0056, HI-2200750, Rev 0
Download: ML21028A645 (3)


Text

February 2, 2021 MEMORANDUM TO:

Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation FROM:

Ekaterina Lenning, Project Manager /RA/

Licensing Projects Branch Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE CLOSED DECEMBER 16, 2020 POST-SUBMITTAL MEETING TO DISCUSS THE REVIEW OF HOLTEC DECOMMISSIONING INTERNATIONAL TOPICAL REPORT HI-2200750, REVISION 0, "HOLTEC SPENT FUEL POOL HEAT UP CALCULATION METHODOLOGY" (EPID: L-2020-TOP-0056)

On December 16, 2020, a closed virtual post-submittal meeting was held between the U.S. Nuclear Regulatory Commission (NRC) staff and Holtec Decommissioning International (HDI) representatives. HDI requested this meeting to discuss the topical report review schedule, format, and the NRC staff initial draft requests for additional information. The meeting was noticed on November 24, 2020, and is available in the Agencywide Documents Access and Management System Accession No. ML20337A378. The list of attendees is enclosed.

Docket No. 99902086.

Enclosure:

List of Attendees CONTACT:

Ekaterina Lenning, NRR 301-415-3151 Ekaterina.Lenning@nrc.gov

ML21028A621 (Package)

ML20337A378 (Notice)

ML21028A645 (Summary)

OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DSS/SFNB/BC NAME ELenning DHarrison RLukes DATE 1/28/2021 1/29/2021 1/29/2021 OFFICE NRR/DORL/LLPB/BC NRR/DORL/LLPB/PM NAME DMorey ELenning DATE 2/2/2021 2/2/2021

ATTENDEES FOR THE DECEMBER 16, 2020, CLOSED POST-SUBMITTAL MEETING TO DISCUSS THE REVIEW OF HOLTEC DECOMMISSIONING INTERNATIONAL TOPICAL REPORT HI-2200750, REVISION 0, "HOLTEC SPENT FUEL POOL HEAT UP CALCULATION METHODOLOGY" EPID: L-2020-TOP-0056 Attendees Organization Robert Lukes US Nuclear Regulatory Commission (NRC)

Philip McKenna NRC Dennis Morey NRC Josh Kaizer NRC Adam Rau NRC John Grasso NRC Ekaterina Lenning NRC Andrea Sterdis Holtec Decommissioning International (HDI)

Pam Cowan HDI Fred Bidrawn HDI Stefan Anton HDI Debu Majumdar HDI Nikhil Varma HDI Abrar Mohammad HDI Enclosure