From:

Callaway, Gary To:

Zoia, Chuck

Subject:

Point Beach Outline review Date:

Friday, February 26, 2021 8:31:37 AM I completed the Point Beach outline review and I have two comments. I discussed these with Jeffrey.

1. The Proposed SRO Admin JPM for EPLAN is to monitor CSFSTs. This is not an EPLAN task.

The requirement changed in Rev. 10 of NUREG-1021. The table that lists ES-301 changes from Rev 9, says

Throughout: All references to Emergency Procedures/Plan have been changed to Emergency Plan.

Emergency procedures were specifically removed from the description of topic 4 of SRO admin JPMs.

I pointed this out to Jeffrey and he said he will replace this JPM.

2. I also asked Jeffrey to come up with good bounding conditions for critical tasks.

He will run the events with no action and see if some bad thing happens (e.g.

unnecessary E-Plan requirement, orange or red path, or complication to mitigation strategy). I told him to call me if nothing bad happens.

Gary W. Callaway Nuclear Regulatory Commission Senior Reactor Technology Instructor