ES-401 Record of Rejected K/As Form ES-401-4 Tier /
Group Randomly Selected K/A Reason for Rejection Tier 1 /
Group 1 RO 15 00065AA1.02 Went to 00065AA1.02 Unable to write a psychometrically sound RO level question based on no plant equipment/component which minimized drain on the instrument air system.
Based on discussion with the Chief Examiner Randomly re-selected 00065AA1.05 Tier 1 /
Group 1 SRO 80 000062AA2.06 Went to 000062AA2.02 Unable to write a psychometrically sound question at the SRO level based on plant documents not identifying time after loss of SWS flow before a component will be damaged.
Based on discussion with the Chief Examiner Randomly re-selected 000062AA2.02 Tier 2 /
Group 1 RO 36 008000A2.03 Went to 008000A2.04 Unable to write an operationally valid and discriminating question with a tie to a high/low CCW temperature based on procedure layout and questions and areas already sampled on the exam.
Based on discussion with the Chief Examiner Randomly re-selected 008000A2.04 Tier 2 /
Group 1 SRO 90 078000G2.1.32 Went to 078000G2.1.7 Unable to write an operationally valid and discriminating question with a tie to a procedural system precaution or limitation at the SRO level.
Based on discussion with the Chief Examiner Randomly re-selected 078000G2.1.7 Tier 2 /
Group 1 RO 40 013000K4.05 Went to 013000K4.19 System does not exist at a PBNP Based on discussion with an exam team member Randomly re-selected 013000K4.19