October 26, 2021 MEMORANDUM TO:

Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:

Ngola Otto, Project Manager /RA/

Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF SEPTEMBER 15, 2021, PARTIALLY CLOSED MEETING BETWEEN FRAMATOME INC. AND THE U.S. NUCLEAR REGULATORY COMMISSION ON INCREASED BURNUP TOPICAL REPORT PRE-SUBMITTAL DISCUSSION REGARDING FUEL FRAGMENTATION RELOCATION AND DISPERSAL On September 15, 2021, the U.S. Nuclear Regulatory Commission (NRC) staff held a partially closed teleconference meeting via Microsoft Team (Open Session) and WebEx (Closed Session) with representatives from Framatome Inc. (Framatome). The purpose of the meeting was for NRC staff and Framatome representatives to conduct pre-submittal discussions on increased burnup topical report (TR) regarding Fuel Fragmentation, Relocation and Dispersal (FFRD), Criticality, and Core Coolability. The meeting was noticed on September 1, 2021, and is available in the Agencywide Documents Access and Management System (ADAMS)

Accession No. ML21244A343.

During the open session, Framatome representatives provided a list of increased burnup related pre-submittal meetings, a background of the applicable advanced codes and methods, scope of the future increased burnup TR submittal, and an introduction on the topics that would be discussed during the closed session, which included core cooling and criticality following FFRD.

There were no questions from members of the public during the open session. During the closed session, Framatome representatives and NRC staff discussed Framatomes presentation on core coolability background, approach, roadmap, and next steps. The Framatome representatives and NRC staff also discussed criticality background information, assumptions, methodology, sensitivity studies, conclusions, and next steps. Framatome intends to have further interactions with NRC as its TR is developed.

A list of the attendees is enclosed. The Framatome presentation materials, including this meeting summary, can be found at ADAMS Package Accession No. ML21256A006.

Docket No. 99902041

Enclosure:

As stated CONTACT:

Ngola Otto, NRR/DORL 301-415-6695

Enclosure List of Attendees Partially Closed Meeting with Framatome Inc. and the Nuclear Regulatory Commission (NRC) on Increased Burnup Topical Report Pre-Submittal Discussions on Fuel Fragmentation, Relocation and Dispersal (FFRD), Criticality, and Core Coolability September 15, 2021 2:00 pm - 5:00 pm NAME ORGANIZATION Bob Baxter Framatome (Framatome)

Morris Byram Framatome Lisa Gerken Framatome Christina Jones Framatome John Klingenfus Framatome Will Maxson Framatome Glen Seeburger Framatome Gordon Wissinger Framatome Michelle Bales NRC (U.S. Nuclear Regulatory Commission (NRC)

Matthew Bernard NRC Mark Blumberg NRC Kristy Bucholtz NRC Alice Chung NRC Paul Clifford NRC James Corson NRC Elijah Dickson NRC Joseph Donoghue NRC Michael Franovich NRC Kevin Heller NRC Lucas Kyriazidis NRC John Lehning NRC NAME ORGANIZATION Shanlai Lu NRC Robert Lukes NRC Joseph Messina NRC Ngola Otto NRC Mathew Panicker NRC Andrew Proffitt NRC April Pulvirenti NRC Mary-Jane Ross-Lee NRC Josh Whitman NRC Brandon Wise NRC Kent Wood NRC Ronald Ballinger ACRS Member

ML21256A006 (Package)

ML21291A062 (Summary)

ML21244A343 (Notice)

ML21256A016 (Open Session Presentation)

ML21256A013 (Closed Session - Proprietary Presentation)

ML21256A007 (Closed Session - Nonproprietary Presentation)

ML21257A208 (Affidavit)

  • via email OFFICE NRR/DORL/LLPB/PM*

NRR/DORL/LLPB/LA*

NRR/DORL/LLPB/BC*

NRR/DORL/LLPB/PM*

NAME NOtto DHarrison DMorey NOtto DATE 10/13/2021 10/21/2021 10/22/2021 10/26/2021