ML21286A489
Text
BFN-29 11.0-i POWER CONVERSION SYSTEMS TABLE OF CONTENTS 11.0 POWER CONVERSION SYSTEMS.......................................................................................... 11.1-1 11.1 Summary Description................................................................................................................ 11.1-1 11.2 Turbine-Generator..................................................................................................................... 11.2-1 11.2.1 Power Generation Objective...................................................................................... 11.2-1 11.2.2 Power Generation Design Basis................................................................................ 11.2-1 11.2.3 Description................................................................................................................. 11.2-2 11.2.4 Tests and Inspections................................................................................................ 11.2-3 11.3 Main Condenser System........................................................................................................... 11.3-1 11.3.1 Power Generation Objective...................................................................................... 11.3-1 11.3.2 Power Generation Design Basis................................................................................ 11.3-1 11.3.3 System Description.................................................................................................... 11.3-1 11.3.4 Inspection and Testing............................................................................................... 11.3-2 11.4 Main Condenser Gas Removal And Turbine Sealing Systems................................................. 11.4-1 11.4.1 Power Generation Objective...................................................................................... 11.4-1 11.4.2 Power Generation Design Basis................................................................................ 11.4-1 11.4.3 System Description.................................................................................................... 11.4-1 11.4.4 Inspection and Testing............................................................................................... 11.4-2 11.5 Turbine Bypass System............................................................................................................. 11.5-1 11.5.1 Power Generation Objective...................................................................................... 11.5-1 11.5.2 Power Generation Design Basis................................................................................ 11.5-1 11.5.3 System Description.................................................................................................... 11.5-1 11.5.4 Inspection and Testing............................................................................................... 11.5-1 11.6 Condenser Circulating Water System........................................................................................ 11.6-1 11.6.1 Power Generation Objective...................................................................................... 11.6-1 11.6.2 Power Generation Design Basis................................................................................ 11.6-1 11.6.3 System Description.................................................................................................... 11.6-1 11.6.4 Power Generation and Safety Evaluation.................................................................. 11.6-5 11.6.5 Inspection and Testing............................................................................................... 11.6-6 11.6.6 Operational Requirements......................................................................................... 11.6-6 11.6.7 Radioactive Waste Discharge.................................................................................... 11.6-7 11.7 Condensate Filter-Demineralizer System.................................................................................. 11.7-1 11.7.1 Power Generation Objective...................................................................................... 11.7-1 11.7.2 Power Generation Design Basis................................................................................ 11.7-1 11.7.3 System Description.................................................................................................... 11.7-1 11.7.4 Power Generation Evaluation.................................................................................... 11.7-3 11.7.5 Inspection and Testing............................................................................................... 11.7-3
BFN-29 11.0-ii POWER CONVERSION SYSTEM TABLE OF CONTENTS (Cont'd) 11.8 Condensate And Reactor Feedwater Systems.......................................................................... 11.8-1 11.8.1 Power Generation Objective...................................................................................... 11.8-1 11.8.2 Power Generation Design Basis................................................................................ 11.8-1 11.8.3 System Description.................................................................................................... 11.8-1 11.8.4 Inspection and Testing............................................................................................... 11.8-4 11.9 Condensate Storage And Transfer Systems............................................................................. 11.9-1 11.9.1 Power Generation Objective...................................................................................... 11.9-1 11.9.2 Power Generation Design Basis................................................................................ 11.9-1 11.9.3 System Description.................................................................................................... 11.9-1 11.9.4 Power Generation Evaluation.................................................................................... 11.9-4 11.9.5 Inspection and Testing............................................................................................... 11.9-5
BFN-29 11.0-iii POWER CONVERSION SYSTEM TABLE OF CONTENTS (Cont'd)
LIST OF TABLES Table Title 11.6-1 (Deleted) 11.9-1 Quality Requirements for Condensate in Storage
BFN-29 11.0-iv LIST OF ILLUSTRATIONS Figure Title 11.1-1a Main Steam - Flow Diagram 11.1-1b Main Steam - Flow Diagram 11.1-1c Main Steam - Flow Diagram 11.1-1d Main Steam - Flow Diagram 11.1-1e Main Steam - Mechanical Flow Diagram 11.1-1f Main Steam - Flow Diagram 11.6-1 Condenser Circulating Water - Flow Diagram 11.6-2 11.6-3 sht 1 Condenser Circulating Water - Flow Diagram 11.6-3 sht 2 Condenser Circulating Water - Flow Diagram 11.6-3 sht 3 Condenser Circulating Water - Flow Diagram 11.6-3 sht 4 11.6-3 sht 5 11.6-4 Condenser Circulating Water - Flow Diagram 11.6-5 Condenser Circulating Water - Flow Diagram 11.6-6 Condenser Circulating Water - Flow Diagram 11.7.1 Condensate Demineralizers - Flow Diagram 11.7-2 Condensate Demineralizers - Flow Diagram 11.7-3 Condensate Demineralizers - Flow Diagram 11.8-1 sht 1 Reactor Feedwater - Flow Diagram 11.8-1 sht 2 Reactor Feedwater System - Flow Diagram 11.8-1 sht 3 Reactor Feedwater - Flow Diagram 11.8-1 sht 4 Mechanical RPV Level Sensing Lines Instruments and Controls 11.8-1 sht 5 Reactor Feedwater - Flow Diagram 11.8-1 sht 6 Reactor Pressure Vessel Level Sensing Lines Instruments and Controls 11.9-1a Condensate - Flow Diagram 11.9-1b sht 1 Condensate Storage and Supply System - Flow Diagram 11.9-1b sht 2 Condensate Storage and Supply System - Flow Diagram 11.9-1b sht 3 Condensate Storage and Supply System - Flow Diagram 11.9-2 Condensate and Demineralized Water Storage Systems - Mechanical Control Diagram 11.9-3 (Deleted) 11.9-4 Condensate - Flow Diagram 11.9-5 Condensate - Mechanical Flow Diagram Security-Related Information - Withhold Under 10 CFR 2.390