BFN-16 TABLE 7.6-1 (Sheet 1)
REFUELING INTERLOCK EFFECTIVENESS Refueling Refueling Platform Service Platform Hoists Platform Mode Situation Position MMH* FMH* FG Hoist Control Rods Switch Attempt Result
- 1.
Not near core UL*
UL*
UL*
UL*
All rods Refuel Move refueling No restrictions fully inserted platform over core
- 2.
Not near core UL UL UL UL All rods Refuel Withdraw rods Cannot withdraw fully inserted more than one rod
- 3.
Not near core UL UL UL UL One rod Refuel Move refueling No restrictions withdrawn platform over core
- 4.
Not near core Any hoist loaded UL One rod Refuel Move refueling Platform stopped or FG not fully up withdrawn platform over core before over core
- 5.
Not near core UL UL UL UL More than Refuel Move refueling Platform stopped one rod platform over core before over core withdrawn
- 6.
Over core UL UL UL UL All rods Refuel Withdraw rods Cannot withdraw fully inserted more than one rod
- 7.
Over core Any hoist loaded UL All rods Refuel Withdraw rods Rod block or FG not fully up fully inserted
- 8.
Not near core UL UL UL L*
All rods Refuel Withdraw rods Rod block fully inserted
- 9.
Not near core UL UL UL L
All rods Refuel Operate service No restrictions fully inserted platform hoist
- 10.
Not near core UL UL UL L
One rod Refuel Operate service Hoist operation withdrawn platform hoist prevented
BFN-16 TABLE 7.6-1 (Sheet 2)
REFUELING INTERLOCK EFFECTIVENESS Refueling Refueling Platform Service Platform Hoists Platform Mode Situation Position MMH* FMH* FG Hoist Control Rods Switch Attempt Result
- 11.
Not near core UL UL UL UL All rods Startup Move refueling Platform stopped fully inserted platform over core
- 12.
Not near core UL UL UL L
All rods Startup Operate service No restrictions fully inserted platform hoist
- 13.
Not near core UL UL UL L
One rod Startup Operate service Hoist operations withdrawn platform hoist prevented
- 14.
Not near core UL UL UL L
All rods Startup Withdraw rods Rod block fully inserted
- 15.
Not near core UL UL UL UL All rods not Startup Withdraw rods No restrictions fully inserted
- 16.
Over core UL UL UL UL All rods Startup Withdraw rods Rod block fully inserted
- 17.
Any Any condition Any condition Any condition, Startup Turn mode switch Scram reactor not at to run power
- LEGEND: MMH - Monorail Mounted Hoist FMH - Frame Mounted Hoist FG - Fuel Grapple UL
- Unloaded L
- Fuel-loaded