Nuclaer Plant, Units 1, 2 & 3, Amendment 29 to Updated Final Safety Analysis Report, Chapter 3, Figure 3.4, Reactivity Control Mechanical Designs
ML21286A321
Person / Time
Site: Browns Ferry  
Issue date: 10/04/2021
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21286A574 List: ... further results
References
Download: ML21286A321 (25)


Text

{{#Wiki_filter:SHEATH c> I I> ' I I} I I II p~\\ I :I COUPLING RELEASE HANDLE _....;... ____ ltANOLE Oil BAIL ITVPICALI N!UTRON A llSOR BER COMPACTED 1111 STAINLESS STEEL TUUES BLADE AMENDMENT 16 BROWNS FERRY NUCLEAR rLAHT FIHAL SAFETY.A.HALYSIS REPORT ConlrDI Rod - hom.i,ic FIGURE J,4*f

U3" COUPLING SOCKET 9.75" COUPLIIIG 1/IElEASE MMDL£ AMENDMENT 1 6 BROWNS FERRY NUCLEAR PLANT FINAL S,V£TY AHA.LYSIS REPORT Control Rod - Isometric FIGURE 3.4-2

CONTROL ROO ASSEMBLY w/VELOCJTY LIMITER .._ ____ UNLOCKING TUBE INDEX TUBE

  • DRIVE COUPLE9 ACTUATING SHAFT AMENDMENT 16 BROWNS FERRY NUCL!AR PLANT FINAL SAFETY ANALYSIS REPORT Control Rod to Con11al Rod Drive Coupling -

llom81ric FIGURE l.4-3

BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CONTROL ROD VOLOCITY LIMITOR-ISOMETRIC FIGURE 3.4-4 CDll ll~POIIT PUU INSERT ,cu,cmunu CllmlTUH WITHDRAW AMENDMENT 16

80TTOII OF REACTOR VESSEL CRIVE HOUSING DRJVt INSERT LIN£ -------,. HLl CKECM VAL¥£ AMENDMENT 16 DRIVE WITHllRAW LINE ARROIIS SNOI WATEI FLOI WHU THE OAIVE I$ Ill THE 'IITKOR.UAL IIQOE 0F.OP£RllTION. PRESSURES SHOflt ARE 11AXl11UII. PR*REACTOR PRE!SURt BROWNS FERRY NUCLEAR PLANT FlHAL SAFETY ANALYSIS REPORT Control Rod Drive, Simplified Component Illustration FIGURE 3.4-6

NOTE: A CIRCLEO NUt.lBER INDICATES A PRESSURE POINT. GUIDE __ _ CAP PISTON _....::.::::.::.-M-a TUBE PRESSURE OVER PORT DRIVE WITHDRAW LINE HOUSING fl./..NGE GUIDE TUBE n C,... COTTER PIN ~ COLLET-FINGERS~~ COLLET-SPRING COLLET-PISTON ANO RINGS © © DRIVE PISTON ANO ~EALS HOUSING TO F'LANGE IIELO .FLANGE ltUB PRESSURE UNDER PORT DRIVE INSERT LINE BALL CHECK VALVE u _...., J....- VESSEL PORTS DRIVE MAIN FLANGE 'liELDtO PLUG POSITION INDICATOR HOUSING AMENDMENT 16 BROWNS FERRY NUCLEAR PLA.HT FIN.A.L SAFETY ANALYSIS REPORT Control Rod Drive, Schematic Diagram FIGURE 3.4-6

t .. **7! t

==---"-=t=====::==!:~ fr~r=-;" r+-++1-1--~'l><l--1-~ I I: oo01.11e PR~n -~1---o--~,~.. "Oft"~~IT).-,'-l>-'1-f'.!--j...j..j ~ I., I 11 DftM: PR.,~ f!EADEIC.,.4p NlAD[R I I llrGIWll.!C L.. QJNllQ\\.11-:_JT AMENDMENT 22 BROWNS fERR'I' NUCLEAR PLANT FINAL SAFE TY ANA.L'l'SJS REFORT CONTROL ROD DR I VE KYMAUL. IC CONTROL SYST[l,I SIMPLJr1co COW'ONENT ILLUSTRATION fJGURE J.4-7

&10~ ~-S8-0 ~93Lt-Z V'l L9 ~ i!"---DRW DI 85-68 ~ I 2-45[779-17 CNDS AND DMNRLZ WATER I 1-47E610-85-1, GS r----------n I ~, H r--8s-~,1 t~~,l ~vl, L~ ~ {HS'\\ an~ G .!. 85-65 ~ N ~ J - FROM CONDENSATE I 0-47E610-2-2, G~ ~ 85-JK ~ r --t-- \\. TE 85-3B y I I I ~ \\__STRAINER ,---...,4-----' STN-85-701 y \\_1/2" DRAIN DRW DRIVE WATER PLIIP MOTOR 2A MTR-85-1 TE TE TE TE 85-JC 85-30 85-JE 85-JF y ~ y ~ I I I I I I ~ ~ 25-21 PI ..,8'5-1 ~9-s PS 5-1 2s-21 I


J.-j D-45[763-41 t©::

9-5 1is'- 0;;;-(w ~., L.!!,Ll ~ 85-1A ~~ T I I I /'H's\\ (TE\\ L---~1 85-JJ / TE TE TE 85-JG 85-JH 85-SC y ~ y I I I I I I ~ ~ RAW COOLING WATER PUMP 2A GEAR BOX GR-85-1 I 2-47E610-24-1C,F7,;>---' TO CCW DISCH 1 2 47E610 24 2,08 I / " '\\ TE TE 85-SF 85-SG y y I I I I I I ~ ~ I I I I I I I I DRIVE WATER PLIIP 2A PMP-85-1 TE 85-58 y I I I ~ r------------------r-t 2-*s<n*-* 1 I~::: ~);:::(_ -l j,):z J, (Hs\\ (Hs\\ J, ~- I L~ ! 85-88 85-BC ! ~-; N '[ _____ J\\N I I r**ov MOV BD 2C I ,c:::,,. 9-5 < r.;-(_ 4 XS ___ /HS) ~~- 85-8 85-SA <<> r.:=<_ 1 ~ ;&:---, N I Mcc [ 5l:~ SEE NOTE 12 I ~-~ ____________ j FROM ORIVE WATER PUMP 18 IL-85-8 ..------------------------------------------------------------------------------------------.r....,;;;..;;_;;...,...,_ ___________ 1-47E610-85-1,F2 I f-~ TO PIC-85-67 ~_,,.._ __ _,,..._*-,/s~,,_-*.-,:2-47E2610-85-2,F7 ~~ 85-510 ~ PREG TO PIC-85-66 CONTROL AIR 2-47E2847-7.G7 ,--,.._""11't-...,,.**-1:2-47E2610-85-2,E7 8,: ~~ 1T.;7 m11,_ I+~+~,+~ I S!Q fO S!Q <<> I 01, ' J (rcvl, 68-1054 TO RECIRCN PUMP A ~FI SEAL INJECTION, .J__ r ~-\\- 2-47E817-1, 971- ,-6"'8-1052 CRW 25-18A Pl 85-9 ~ 5-18A PI 68-105!,1--I CRW riii19 85-11 y I I .J....25-18A ...r 9-19 (FT\\_ ________ frn\\ __ 85-11 85-11C FE '-( .............. 85-11 ~ 25-18A 1----!!:_DIS 85-10*~---.. y I ~-5 85-10 ~ (F7\\S-18A 85-11 B TO RWCU PUMP A & B

~

BEARING SEALS <2-47E610-85-4.G6f--

--1

~9-5/PI\\ 25-18B,

  • 85-13A 85-138 y

y 85-509 - L ~~ . =--rs:i--: - .x ~ ::i,-Ic;< f .--~/=?.~:::;::i""'1 ~9-5 I.,.f.. cv\\ I G I~ 85.::2_!.A L 25-188 85-1~A ,C:::-,.. R t I /CCV\\ ZI-85-11 AB I

-18e

~ _ 1

-5

_l_25-18A 85-11

  • ~ *

~ _fxs '\\ i 85-11 85-11 PI I ~ .6 8~ V 25-188 PI 85-12 ~ ZI 85-1188 1 (Fcv\\ j 25-18B' 85-11B I I I +----+--- 25-188 PT T" ~l_)j.< L~... ~::c~..,_,, I "'")C.,(, 9-5 > * ~=1.J.~ Hats-8 7 1 I ~-196?\\-19 85-13 85-13 ~-5~ 85-13 ~ 85-13 PI 85-14 ~ 25-188 TO CHARGING WATER HEADER ---,2-47E2610-85-2,E2 6 X B. 5 TO DRIVE WATER HEADER ---12-47E2610-85-2,F2 25-188 ~ 9-5 85-16 l'.£U 85-15A 2s-1**T (FI\\_ 85~8 -1 FE 85-15 25-188 FT 85-15 V @19 FM 85-15 y d1s19 85-15 ~ I ~ ~I I ~-5 I ~-5 /fcv\\_ _ - -... ~ -,L. ~ 85-20A ~ 85-20 85-47 ___K7t--.--~ )1:;.*:i------1:t-~---i ~ X I _x I ~----J 8s~e I /f"cv\\_l 85-21A i )1. I I I ~l-..l..----t*~x 1¥1--f'---1 25-18A Av I /PI\\ at;~}- _J Bt-Y 7 EXHAUST WATER HEADER --<2-47E261D-85-2,G2 I 25-188 PI l--!.85-29 ~ 0 r----m----....... ~ 2-45E779-8 9-5 25-18A 9-5 )';;'{J I (Fl\\ ~ ! ~ (Hs\\ ? ~-...J 85~A 85YB 85-50A ~ ~ 85-508 ! ~ _ ~ L ___ _. L __ i __ y N I ..., _1_9-19 .J_ 8 )';:.--(_ I lEJLl (xs\\,_ fas\\ '? ~--, 9_1985-30 85 85-50C ~ ~-_J ,v~ ;;:~ I (px\\ I ~ -1 I 480V MOV 80 2C I ~..L .J... r-----_J ~ 25-18A(FT'\\ MCC (Fcv, 85-30 IL-85-50 85-50 I FULLY OPEN~. t_...,_, _____...,'-1),<],--£-"'~~-s;~~;;;:---.,"""'.=:--r~;:;~-f>-<l- _\\i1:1--f><-~~ts":it.iT-l><1-T1FE r

  • f...l
    :"j& MCC

~ );;-(_---Q-(PI\\25-1BA 8~ 5Q:TW y---.J 85-501 ~ RWCU SYSTEM 2-47E610-69-1,H7 25-1 BA I (Pcv\\

  • IL 23 l

~ / *cv, l 85-28 25-18A /4?\\ I 85-23 ~ IL-85-27 85-27 I 'y" 25-1 BA l25-18A ~ ~ 9-5 ~ G r, c!i r R 9 9-5 ~ ~ r~* I < i--~ m ©**- ~ - --~~ £---I <L-~,-~ 8:.~1 OT 1....,,_JSDI I in HS HS in I ---- It) HS HS It) I 85-17 I 55_178 ~ "fl 85-23A 85-238 "fl~ 1 1 ~ °1'85-21e a5-27A '? ~ I I -- ~ I L N N 1 1 _ ____ N ....J 19-5 -~ 1/EPD 85-17A 25-18A OT ,--r:---,- 85-18 A-s.,..L:5-18~.1..Js-18A ;,,; ~ (PD I'\\ ( PX '\\ 85-18A 85-188 85-18 9-19 9-19 FE 85-25 25-188 FT -. -- 85-25 (Px\\ 85-25 j 85-25 - 4 ..G~s---r,.::,.; l£.U 25-188/'FI'\\ ~5-25A ~ 85-258 -- ( PI ' -- L __ _:8::.'t_:::-c~:'.,6_~TtD~C~D~O~LtI~NG~WtA~T~ER~H'.:::.;EADER 2 47E2610-85 2,F2 RX VESSEL PRESSURE ..,_ 2-47E610-68-1.H6 I 3 COMPANION DRAWINGS, 1-47E610-85-1 2-47E610-85-2 2-47E61D-85-4 2-47E610-85-5 NOTES:

1. THE CONTROL ROD DRIVE (CRb SYSTEM IS DESIGNED TO PROVIDE THE REACTOR WITH POSITIVE REACTIVITY C NTROL WHILE MAINTAINING A CONSTANT QUANTITY OF CONDENSATE TO THE REACTOR VESSEL IN THE FORM OF DRIVE SEAL LEAKAGE, DRIVE COOLING, AND DIRECT FLOW TO THE REACTOR. THE PUMP SUCTION IS FROM THE CONDENSATE STORAGE SYSTEM AND IS RAISED TO A PRESSURE ABOVE THE REACTOR OPERATING PRESSURE BY THE DRIVE WATER PUMPS. THE PRESSURE IS THEN REDUCED TO THE THREE PRESSURES NEEDED FOR DRIVING, CHARGING, AND COOLING.
2. UNITS 1 AND 2 SHARE THE SPARE DRIVE WATER PUMP l1B~ WHILE UNIT 3 HAS ITS OWN SPARE. EACH PUMP IS CAPABLE OF SUPP YI G 100 GPM AT 1500 PSIG.
3. THE CRD HYDRAULIC SYSTEM PROVIDES CRD OPERATING FLUID, CRD COOLANT, ACCUMULATOR CHARGING AND EXHAUST WATER TO THE REACTOR.
4. THREE STAGES OF WATER PRESSURE ARE DERIVED BY THREE SEPARATE REGULATING SYSTEMS. THE SCRAM ACCUMULATOR CHARGING WATER IS AUTOMATICALLY REGULATED TO 1400 PSIG. THE FLOW CONTROL SYSTEM USING FCV-85-11A ORB ANO FE-85-11 MAINTAINS 100 GPM TO THE SYSTEM.

CRD DRIVE WATER IS MAINTAINED AT REACTOR PRESS. (PR) + 250 PSIG BY CONTROLLING PCV-85-23 AND THE AUTOMATIC CLOSING OF FCV-85-20A OR 21A DURING ROD MOVEMENT. THE COOLING WATER HEADER PRESSURE IS REGULATED TO PR+ 20 PSIG BY POSITIONING PCV-85-27. ONE HUNDRED GALLONS PER MINUTE !100 GPM) FLOWS INTO THE REACTOR WHETHER OR NOT THE CONTROL ROD ARE MOVING OR AT REST.

5. EACH CRD IS EQUIPPED WITH A SEPARATE SCRAM ACCUMULATOR WHICH IS CHARGED WITH NITROGEN. THE NITROGEN CHARGING HEADERS ARE MAINTAINED AT 1400 PSIG. ACCUMULATOR CHARGE PRESSURES ARE MONITORED BY LOCAL PRESSURE GAUGES PI-85-34 AND PS-85-34 WHICH ALARM LOW PRESSURE. ACCUMULATOR DIAPHRAGM INTEGRITY IS ALARMED WITH THE USE OF LS-85-34.
6. CRD POSITIONING IS ACCOMPLISHED BY ELECTRICAL CONTROL OF THE INSERT VALVES FCV-85-40A AND DOR THE WITHDRAW VALVES FCV-85-408 AND C.
7. EACH CONTROL ROD, AS IT TRAVELS UP ~INSERT6 OR DOWN iWITHDRAW)

PASSES A NUMBER OF SWITCHES. THE TO TWO P SITION SW TCHES ZS-85-41 A AND B ARE CALLEO "OVER TRAVEL" AND THE BOTTOM TWO POSITION SWITCHES ARE "WITHDRAW BACKSEAT" ZS-85-42 AND "WITHDRAW DISCONNECT" ZS-85-43. THERE ARE 48 SWITCHES BETWEEN THESE LIMITS ZS-85-44 (-1 THRU -48). THEY ARE DIVIDED INTO TWO SETS. ODD NUMBERED SWITCHES (EXAMPLE FOR CRD NUMBER 1: ZS-85-44-1 5 ETC.) ARE THE ROD RIFTING SWITCHES AND THE EVEN NUMBERED SWITCHES ARE THE CRD LOCKED POSITION SWITCHES. THE ABOVE SWITCHES ARE ACTUATED BY A MAGNET IN THE POSITION PROBE. THE ROD POSITION IS DISPLAYED IN THE MAIN CONTROL ROOM ON PANEL 9-5 REACTOR PANEL.

8. INSTRUMENTATION ASSOCIATED WITH BACKUP CONTROLS IS LOCATED AS SHOWN ON THE DIAGRAM. IF A LOCATION IS NOT SHOWN THE DEVICES WILL BE LOCATED ON THE APPROPRIATE 4160V AC BOARD, 480V AC BOARD, OR 250V DC BOARD. (REF GE DESIGN SPEC. 22A1470)
9. THIS CONTROL LOOP HEADER IS PIPED ONLY TO CRD MODULES 26-55, 30-43, 30-07 AND 30-23, PI-85-71A AND 8 ARE ASSOCIATED ONLY WITH CRD MODULES 30-43 AND 30-23 RESPECTIVELY.

1 0. ALL COMPONENTS SHOWN HAVE UNIT 2-PREFIX, UNLESS OTHERWISE NOTED.

11. PARTIAL LOGIC FOR CONTROL ROD DRIVE SYSTEM IS SHOWN ON THE MECHANICAL LOGIC DIAGRAM LISTED IN REFERENCE DRAWINGS.
12. 2-FCV-85-8 MAY BE OPENED OR CLOSED TO SUPPORT PLANT OPERATIONS EXCEPT WHEN CRD PUMP 18 IS NEEDED TO SUPPLY WATER TO THE UNIT 1 CRD HYDRAULIC CONTROL SYSTEM WHERE 1-FCV-85-8 VALVE IS OPENED. THIS CONDITION REQUIRES THAT 2-FCV-85-8 BE CLOSED.

REFERENCE DRAWINGS: 0-45E763-4.............. 4160V SHUTDOWN AUX POWER SCHEMATIC DIAGRAM 2-45E763-6.............. 4160V SHUTDOWN AUX POWER SCHEMATIC DIAGRAM 2-45E779-7,-B,-17....... 480V SHUTDOWN AUX POWER SCHEMATIC DIAGRAM 2-471600-224............ RPS-CR CONTROL AIR PRESSURE PANELS 0-47W600-224A........... RPS-CRD CONTROL AIR PRESSURE PANELS MEL..................... INSTRUMENT TABULATIONS-CR 2-47E610-1-2............ MECHANICAL CONTROL DIAGRAM-MAIN STEAM SYSTEM 0-47E610-2-2............ MECHANICAL CONTROL DIAGRAM-CONDENSATE & DEMINERALIZED WATER STORAGE SYSTEM 2-47E610-68-1........... MECHANICAL CONTROL DIAGRAM-REACTOR WATER RECIRCN SYSTEM 2-47E610-69-1........... MECHANICAL CONTROL DIAGRAM-REACTOR WATER CLEANUP SYSTEM 2-47E2610-74-1.......... MECHANICAL CONTROL DIAGRAM-RESIDUAL HEAT REMOVAL SYSTEM 2-47E610-85-1, -2, -4... CONTROL DIAGRAM-CR HYDRAULIC SYSTEM 2-47E2610-85-2.......... MECHANICAL CONTROL DIAGRAM-CR HYDRAULIC SYSTEM 0-47E800-1.............. FLOW DIAGRAM-GENERAL PLANT SYSTEMS 0-47E800-2.............. MECHANICAL SYMBOLS & FLOW DIAGRAM DRAWING INDEX 2-47E810-1.............. FLOW DIAGRAM-REACTOR WATER CLEANUP SYSTEM 0,1,2,3-47E820-SERIES... FLOW DIAGRAM-CR 2-47E852-2.............. FLOW DIAGRAM-DRAINAGE-REACTOR BUILDING 2-47E2847-1 & -7........ FLOW DIAGRAM-CONTROL AIR GE DRAWINGS: 2-791E201-2 & -3....... CRD HYDRAULIC INSTRUMENT CONTROL SYSTEM 2-730E321-14........... REACTOR MANUAL CONTROL SYSTEM 730E145................ CRD HYDRAULIC CONTROL UNIT. PIPING AND INSTRUMENT DIAGRAM 729E499................ CR FUNCTIONAL CONTROL DIAGRAM AMENDMENT REACTOR BUILDING UNIT 2 28 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CRD MECHANICAL HYDRAULIC SYSTEM CONTROL DIAGRAM FIGURE 3.4-8a SH 1 H G F E D C B A

8 7 ill"~*n,n r<*HH*~*-" I I @1-11 H-H I 1--l ~~,-.,,~ *t ~---r--T-@~-1~:fr~ l1-1JCD1&-1Jt-i-r-4----, L----l ---1 I ~rffl-lYiMn~ ~~-JI 1 ,sv I,sv, 1 --------<1-m111hl-1,A1 I TDIDIAIIIIOl.1111: l'rn, ' I I IIIIAIN,1:11*1 I I I ,--<z-t1H11H-I,M I r---;:i=',i=-n-1 @:-'- ::. Lffl2~tl- ~--- ZS IIHMITE I ~ +-----------~-7 1nrn:AL IX",":1\\/C

..
.:..:::_---~~:::;;='.;,;:;;;t:::::i IIIIUAL I I

~~ffl 11'1 i 1----,,,..,_,. I -11 I I TOfSV-H-7l7 II 1--T---j 11E1110-A-5 HI) J-731 114 Zl-1&- I 5l'SIDI 6 5 3 (ij$-~IIOIIDIT01 I Cl-1:10Lll1-IJ I r----------+--------, ~;:.m= ~-;__n y ~::1~11,111

  • y 11-73DEJ11-111 L __________ T ________ J f!'..w.,,I¥mN&.E-!

l-ll lz-7JDEJIH4 ~--t-~-/4'!,=M~,w ~,'i'l.! ~~ 1 ~f,'l:\\M ~ ,"ill.! fUifift1' 111 = COCI.IIICIATDIIUDl:I (1 1n10-11-1 *.u! AMENDMENT 29 POWERHOUSE UNIT 2 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CRD HYDRAULIC SYSTEM MECHANICAL CONTROL DIAGRAM FIGURE 3.4-Sa SH 2 H G F E D C 8

A B C D E F G H I J K 1 2 3 5 7 8 v(Qij l-S8-0!93Lt-£ Vi L9 CNDS & DMNRLZ WATER I 0-47E610-2-2, F4 f~l I 45E779-171 85-56 11 POI 5-68 ~~: DI ~ p~ 85-69 ~ i~ 85-56 I I t t;}..J_j CNDS ~ DMNRLZ WATER y I 0-47E610-2-2, H4 '- DRW DRW ~5-21 STRAINER STRAINER I 2 STN-85-701 STN-85-707 __/ 9-5 y ~55-5A-2 y 1/2" DRAIN _/ A 1/2" DRAIN _/ I THIS DWG,B4 1 rlii-~- 7 ~5-21 DRW DRW I I 1 25-21 I (Hs\\ 9-5 PS 25-21 I 5-2 _i ___ 85-2A PS ---r----------------------------~-- ---4 0-45E763-4 I I y ~ 5-1 I I

THIS DWG. 88 I

3-45E766-22f---- - ---- - - ----f I I t---j3-45N3616-3 I r----....J ~ r-r-T-~-5 I I 55-5A-23 I I ©00-llili ili I I PA ~ 13-45N3616-3 ~-- I 9 1 43-45N3616-31 I I I 85-2 I I I ~ I I 8 I l~GI I l..-7 t 4 3-45N3616-3 I ~ I ~9-5 ~ I ~ I I I I I I 8y I I A3190 I ~ ~ ~ I I I@ 4 I fTCv' L_ ---j 3-45N3616-3 I I I 3-45N3616-3 ~ rt.'\\ 6 ---- I L---1 ~ ~5-6~ ~ ~ I (HS\\_ ____ ~ ~ ~5-6~ I HS TE t I E L_ "-1 8t-~ 8t°, (PI\\ 8 t-'5 8~~ I 8~ 85-2 St-~ 8t-~ I I I I L----------+---~ TE 85-62A I I I I TE r ~ 85-62.A r ~ 85-62B DRIVE WATER DRIVE WATER DRIVE WATER PU,.. MOTOR / PllotP JA PllotP MOTOR MTR-85-1 / Pl,l'-85-1 MTR-85-2 / PUW:- JA PLIIP 38 GEAR BOX GEAR BOX / GR-85-1 / GR-85-2 3A JB '\\ TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE 85-38 85-3C 85-30 85-3E 85-JF 85-3G 85-JH 85-5C 85-SF 85-5G 85-58 85-48 85-4C 85-4D 85-4E 85-4F 85-4G 85-4H 85-SC y y ~ y ~ y ~ y y y y y y ~ y ~ y ~ y r I I I I I I I I 3-45N3616-3 ~ -1 I I I 1--j3-45N3616*31 I t--l3-45N3616-3 I t-i3-45N3616-3 I I I --4 ~ "13-45N3616*3 I I-45N3616-3 I ~ -j3-45N3616-3 I 1-i 3-45N3616-3 I r--4 I I 13-45N3616-3 f-- --f I I I I I I I-45N3616-3 I I I I I I 13-45N3616*3 ~...J I I I I L I ~ 5 ~


j3-45N3616*31 TO RECIRCN PUMP A SEAL INJECTION

< 3-47E817-1,A8 25-18A PI 85-9 ~ 0 ~ 1 ~ 8 RAW COOLING WATER l3-47E610*24*1, CB> (3-47E844-2, C4) FROM CONTROL AIR 3-47E3847-7,G6 r,.. c I J ) "" (rcv\\ /fCV\\ 68.::_1_g54 68T55 /FI\\_ 5-18A PI 68-1052 68-1051 L0) ~ ~ CRW ~ 68-1053 ~ DRIVE WATER ~CRW FILTER A 615," X I/ -0 85-11 y I I ~-18A ..,-(FM'\\-19 FM 85-11 85-11C 25-18A FE y 85-11 I DIS ~ ~ I~ I A3191 2 I Lj3-45N3616*31 TO PIC-85-66 3-47E610-85-2,F3 f f TO RECIRCN PUMP B SEAL INJECTION I 3-47E817-1, A2 '7 ~ 1~* M r--- 85-11A -~ 25-188 I I PI ~5 ~5-18A Bs-11 ~ FIC s 85-11 85-11 ~ y I

  • v*

~ 7 ~ 4 ~ 2 ~ ~ ~ 7 TO PIC-85-67 3-47E610-85-2,E3 25-188 PI 85-12 ~ m-9-5 ~ I I I 5 CRD HYO STABIL {Fcv\\_ I£ SOL VLVS


4 XS


13*730E321*12 *141 TO DRIVE WATER HEADER 85-20A I 85-20

---l3-47E3610-85-2,CIO -0 ¥A I -- X I .x - I 13-791 E202-3 ~ 7 _A{ I ~ I f 'C 'C 'C f~ I a5-;6e ----1 ), ), 25-1 BB I ~ I x_ ---1!1) 9-5 a5-16 @I tfcv\\_-t }.. -,~9-5 ~ 85-15A I 85.. A 25-18BT I 1-3El 3-ZI-85-11 AA A I -ltj R 25-188 (FI\\__ .J

  • x I

(FCY\\ I Yfil: 85~8 i I FI FE -0 .x 85-22 85-2 ~as~A L~ 25-188 25-188,J"'""@19 25-18 ~J (Pcv'\\ ZI-85-11AB FE FT FM 1 CV 85-15 85-15 85-15 ~ y 85-218 ~ @19 X [Ceb V 85-15 i" ' ~ ' 85-92 ~ EXHAUST I. ~ - WATER FILTER i--- R MCC 3-47E610-85-3 9 TO CCW DISCHARGE 3-47E610-24-2, D8 ~ +---j 3-45N3616-3 I I ~ I I -13*45N3616-31 I r---- I I I I ~ rf.\\ t (PI\\*t-5 8t°~ I I I I 85-628 I I I I DRIVE WATER / PUii' JB PMP-85-2 '\\ TE TE TE 85-SF 85-6G 85-68 y y y I 1---j 3-45N3616*31 I r--1 I I I I I I 3-45N3616-3 f-~ I ~ ~ ~ I D 1 6 I I L--j3-45N3616*31 RETURN EXHAUST WATER 3-47E3610-85-2,810 25-188 PI 10 1 1 12 ~~~E~~T~8[E~OD DRIVE {CRO) SYSTEM IS DESIGNED TO PROVIDE THE REACTOR WITH POSITIVE REACTIVItY CONTROL WHILE MAINTAINING A CONSTANT QUANTITY OF CONDENSATE TO THE REACTOR VESSEL IN THE FORM OF DRIVE SEAL LEAKAGE ORI VE COOLING, ANO FLOW TO THE REACTOR VIA RWCU RETURN LINE. THE PU PRE MP SUCTION IS FROM THE CONDENSATE STORAGE SYSTEM AND IS RAISED TO A SSURE ABOVE THE REACTOR OPERATING PRESSURE BY THE DRIVE WATER PUMPS. PRESSURE IS THEN REDUCED TO THE THREE PRESSURES NEEDED FOR DRIVING, THE CH NO 1.

2.

ARCING AND COOLING. TES: HYDRAULIC CONTROL UNIT (HCU) DEVICES AND CONTROL ROD DRIVE UNIT (CROU) DEVICES ARE SHOWN FOR A SINGLE UNIT AND ARE TYPICAL OF 185 SUCH UNITS. THE DRIVES ARE NUMBERED IN ACCORDANCE WITH TABLE 3 ON 3-730E321-4. UNIDS OF ALL CCMPONENTS AFFILIATED WITH A PARTICULAR DRIVE WILL HAVE A SUFFIX THE SAME AS THE DRIVE COORDINATE. FOR EXAMPLE, THE UNI FOR FLOW CONTROL VALVE 398 ASSOCIATED WITH DRIVE 2-43 WOULD BE 3-FCV-85-398/243, AND FOR CYLINDER 718 WOULD BE 3-CYL-85-718/243. A 3, UNITS 1 AND 2 SHARE THE SPARE DRIVE WATER PUMP (18\\ WHILE UNIT 3 HAS IT'S OWN SPARE. EACH PUMP IS CAPABLE OF SUP~LY NG 100 GPM AT 1500 PSIG. THE CRD HYDRAULIC SYSTEM PROVIDES CRD OPERATING FLUID, CR COOLANT, 8 ACCUMULATOR CHARGING AND EXHAUST WATER TO THE REACTOR.

4.
5.
6.

THREE STAGES OF WATER PRESSURE ARE DERIVED BY TWO SEPARATE REGULATING SYSTEMS. THE SCRAM ACCUMULATOR CHARGING WATER IS AUTOMATICALLY REGULATED TO 1400 PSIG. THE FLOW CONTROL SYSTEM USING FCV-85-11A ORB AND FE-85-11 MAINTAINS APPROXIMATELY 65 GPM TO THE SYSTEM CRD DRIVE WATER IS MAINTAINED AT REACTOR PRESSURE. CPrl + 250 TO 270 PSIG BY CONTROLLING PCV-85-23 AND THE AUTOMATIC CLOSING OF rcV-85-20A OR 21A DURING ROD MOVEMENT. THE COOLING WATER HEADER PRESSURE IS APPROXIMATELY PR+ 20 PSIG. SIXTY-FIVE GALLONS PER MINUTE (65 GPM) FLOWS INTO THE REACTOR WHETHER OR NOT THE CONTROL RODS ARE MOVING OR AT REST. EACH CRD IS EQUIPPED WITH A SEPARATE SCRAM ACCUMULATOR WHICH IS CHARGED WITH NITROGEN. ACCUMULATOR CHARGE PRESSURES ARE MONITORED BY LOCAL PRESSURE GAUGES PI-85-34/219 THRU 5843 AND PS-85-34/219 THRU 5843 WHICH ALARM ON LOW PRESSURE. ACCUMULATOR PISTON INTEGRITY IS ALARMED WITH THE USE OF LS-85-34/218 THRU 5843. CRD POSITIONING IS ACCOMPLISHED BY ELECTRICAL CONTROL OF THE INSERT VALVES FCV-85-40A/219 THRU 5843 AND FCV-85-40D/219 THRU 5843 OR THE WITHDRAWAL

7. VALVES FCV-85-408/219 THRU 5843 AND FCV-85-40C/219 THRU 5843.

C EACH CONTROL ROD, AS IT TRAVELS UP (INSERT) OR DOWN (WITHDRAW) PASSES A

8.
9.

NUMBER OF SWITCHES. THE TOP TWO POSITION SWITCHES ZS-85-41A/219 THRU 5843 AND ZS-85-418/219 THRU 5843 ARE CALLED *ovER TRAVEL". THE BOTTOM TWO POSITION SWITCHES ARE *wITHDRAW BACKSEAT", ZS-85-42/219 THRU 5843 AND

  • WITHDRAW DISCONNECT", ZS-85-43/219 THRU 5843. THERE ARE 48 SWITCHES BETWEEN tt55~Ef!~IfRE2~D85N~~6~~lDT~=~TE~~~ AR~ t~~u*Rt8'oRI~iIN~R~w~f~A~~Q l~ioTHE EVEN NUMBERED SWITCHES ARE THE *LOCKED POSITION SWITCHES".

THE ABOVE SWITCHES ARE ACTUATED BY A MAGNET IN THE POSITION PROBE. THE ROD POSITION IS DISPLAYED IN THE MAIN CONTROL ROOM ON REACTOR PANEL 9-5. INSTRUMENTATION ASSOCIATED WITH BACKUP CONTROLS IS LOCATED AS SHOWN ON THE DIAGRAM. IF A LOCATION IS NOT SHOWN, THE DEVICES WILL BE LOCATED ON THE APPROPRIATE 4160V AC BOARD, 480V AC BOARD OR 250V OC BOARO. (REF GE OESIGN SPEC 22A1470) LEADING ZEROS SHOWN IN MEL AS PART OF THE UNI ARE NOT DEPICTED. FOR ADDITIONAL GUIDANCE, REFER TO NEDP-4. SY MBOL: 0----,,.-coNTROL AIR REF ERENCE DRAWINGS, 0-45E763-4.......... WIRING DIAGRAM - 4160V UNIT AUX POWER SCHEMATIC DIAGRAM 3-45E766-22......... WIRING DIAGRAM - 4160V SHUTDOWN AUX POWER SCHEMATIC DIAGRAM 3* 45N3616-3......... WIRING DIAGRAM - THERMOCOUPLES & RTD'S CONNECTION DIAGRAM 3-45E779-7,-8....... WIRING DIAGRAM - 480V SHUTDOWN AUX POWER SCHEMATIC DIAGRAM ME L................. INSTRUMENT TABULATION CONTROL ROD DRIVE-SYSTEM 85 a-47E610-2-2........ CONTROL DIAGRAM - CONDENSATE & DEMINERALIZED WATER STORAGE SYSTEM 3-47E610-24-1,-2.... CONTROL DIAGRAM - RAW COOLING WATER SYSTEM 3-47E610-68-1....... CONTROL DIAGRAM - REACTOR RECIRCULATION SYSTEM 3* 47E610-69-1....... CONTROL DIAGRAM - REACTOR WATER CLEANUP SYSTEM 47 E800-1............ FLOW DIAGRAM - GENERAL PLANT SYSTEMS 0-47E800-2.......... MECH SYMBOLS & FLOW DIAGRAM DRAWING INDEX 3-47E817-1.......... FLOW DIAGRAM - NUCLEAR BOILER 0-47E820-1.......... FLOW DIAGRAM - CONTROL ROD DRIVE HYDRAULIC SYSTEM 3-47E844-2.......... FLOW DIAGRAM - RAW COOLING WATER 3-47E3847-7.......,.FLOW DIAGRAM - CONTROL AIR SYSTEM GE HERAL ELECTRIC REFERENCE DRAWINGS: 72 9E499............. FUNCTIONAL CONTROL DIAGRAM - CONTROL ROO DRIVE 73 OE145............. PIPING & INSTRUMENT DIAGRAM - CR HYO CONTROL UNIT 3-7 30E321-14........ ELEMENTARY DIAGRAM - REACTOR MANUAL CONTROL SYSTEM 3-7 30E915-17........ ELEMENTARY DIAGRAM - REACTOR PROTECTION SYSTEM 3-7 91E202........... ELEMENTARY DIAGRAM - CRD HYO INSTR SYSTEM D E F G 85-29 r------i-r-rl3-45E779-a 1 ~ I ~ I I 9 5 G R I 25-18A 9-5 (FI\\ ~~ HS I 85-JOA 85-308 ~85*50A 85*5DB I y y IG L~~~ L--- L--7 XS HS ..,-@-19 FM I 85-50 85-50C 9-1985-30 y ~ I ~ I 85_30 -t--j3-791E202*31 I ~25-18A L~~-f-~MCC 85-30 IL-85-5D H FE 85-30 I ' ~

  • i ~I 85-10 I

I 25-18A y r-f:5)5* 1 *A I cv\\ IL-85-23 25-18A 13*791E202-31--,-----~----7 I '- SPOOL PIECE 25-18A r---4 I ~ (F?\\5-18A ~-5 I I ~-5 I I I~ I 25-1 BA DA 1 85-118 85-11A I a5-10 ~ ~ I OT I ~ 85-17 r ~ L ___ M L-j3-791E202-3 I ' 85..:!,_!,8 /fCV\\ r~ 25-18B TO RWCU PUMP A & 8 '. BEARING SEALS j._ 85_118 I r~ zI-a5-11ss < 3-47E610-85-4,G6f-- I/ -0 @9 _,(PI\\ I I-1--J.!.--3ID: 9-5 85-13A 85-138 y Y25-1ae I 3-ZI-85-11BA I I 25-188 - i . 1--.l..~ DRIVE WATER 13-791'202-3 f---+------- PT FILTER 8-85-13

  • x*

I I W7L ~-19~-19 PX 85-13 85-13 25-188 ~ TO CHARGING WATER HEADER ~-5 PI 85-14


:J-47E3610-85-2,E10>

A ~ 85-13 ~ 1 2 3 4 5 6 I 85-23 85 17 I l I~ I 25-18A~ 9-~ DI I HS HS 1 8'5-178 ~ 85-23A 85-23e I -- I 9-5 I ¥. ~ J /POD j_____ I"'.::!.' L-j3-45E779*7 I 25-18A I I OT FE r-1--1---,- 85-18 85-25 I I ~5A_,~5-18A',... I I DI DI PX I I 85-18A 85-188 85-18 ~ ~ ~ I I I L --13-791 E202*3 I 25-188 I (PI\\ I 8t-~ L-43-791 E202-3 I 7 PI PI 85 85-28 ~ r--!3-791E202-3 I I 25-188 I v-.. 9-19 9-19 FT _ _j__ mi\\ (m 85-25 T 85-25 85-25 ~ I ~ ~-----~_J -5 25-188 25-188 FI 85-25A (PI\\ 85-258 ~ ~ 8~ TO COOLING WATER HEADER 3 47E3610 85 2,010 RX PRESSURE 3 47E610 68 1,A5 '). 8 C (STRAINER) PI 85-31 ~ RWCU SYSTEM 3-47E610-69-1,H7 > CCMPANION DRAWINGS: 47W610-85-4 47W1610-85-5 1-47E610-85-1 1-47E1610-85-2 2-47E610-85-1,-4 2-47E261D-85-2,-5 2-4712610-85-6 3-47E610-85-3,-4,-5 3-47E3610-85-2 9 10 AMENDMENT 28 POWERHOUSE UNIT 3 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT ROD DRIVE HYDRAULIC SYSTEM CONTROL MECHANICAL CONTROL DIAGRAM FIGURE 3.4-Ba SH 3

LOIi Z-!::9-0L9nlt-t ,i L9 !JFv:fP'IDI --t=:,.141 _4:.~-!!.~.) _,\\:,:;::?,:,:, tf\\_/v3 E----~ 10 ra'.'f.~h.na CODl.lllc:IATEI ~ 10 11 J-TE-7-0Cl1 Hl7Dll1

J-TE-13-7--

M57DOZ

J-TE-13-7-11113

"'57003 J-TE-13-7-- AIS700f J-TE*l5*7-AIS700II J...TE-11*7-AU700I 3-TE-11-7-11117 AM7001 J-T£-ID*7-AM7DOI J-Tl:-11*7-AM7tllt l,-Tt-H-7-o10 -7010 J.-Tt-H-7-o11 M.17011 >-TE*H-7-olZ MS701J

J-TE*IJ-7-913 "'57013
J-TE*IJ-7-014 "'57014
J-TE-13*7-tl'IJ o\\157015 J-TE*l5*7-1111 AIS7011 J...TE-ID-7-017 AU7017 3-TE-11-7-011 AM7011
l-Tl:-11-7-011 AM7011 J-Tl:-11-7-0llD AM7Dm J.-tt-11-7-0lll AM7tll1 J.-lt-H-7-0:H M.570lt J-Tl:*H-7-0ZI MS7CIU J-TE*IJ-7-0:Zt M570H
J-TC-13*7-0:H

"'571115

J-TE-13*7-tlH o\\157011 J-TE*l5*7-IIZ7 AIS7017 J...TE-15-7-11111 AU7ml 3-TE-11-7-021 AU702.I
1-TC-11-1-0.10 AM1mo J-TC-11-7-0.11 AM7m1 J.-TC-11-7-0H AM7tlll

.l,-lt-H-7-0U MS70U J-Tl:*H-7-0H MS7DH J-TE*H-7-0H M5711JS

J-TC-13*7-<<II M57DJI
J-TE*IJ-7-1137 AU7DJ7 J-TE-15*7-tllll AIS7031 J...TE-ID-7-0H AU7031 3-TE-11-7-IMDAU7040 3-TC-11-7-041 AM71J4.1 J-TC-11-7-041 AM71J4.J:

J.-TC-11-7-0H AM7D43 l-Tt*H-7-+lt M57044 J-Tl:*H-7-otJ MS7D1-0 J-TE*H-7-otl M5711M

J-TE-15-7-7 o\\1570.7
J-TE-15 M5704a
J-TE-15 o\\157(14.1
J-TE-15*7-DIID M570IIO
J-TE-11-7-1111 AU70ll1
J-TE-11-7-1112 AU70ll2
1,-TC-11-7-1113 AU711U
1,-TC-11-7-0ll4 AU7DM
1,-TC-H-7-0H M570ll5
J-TE-H*7*0H Ml7-
J-TE-H*7-D117 o\\1571>>7
J-TE-15*7-1111 M570III
J-TE-15*7-1111 M57-
J-TE-15*7-IIID M57DIO
J-TE-15*7-1111 M57Dl1 12 J*TE*U-7-DU AH7lllll J-TE-15-7-121 AU712a J-TE-7-GM IJ57DM J*TE*l5*7*1H Mll71ZI J-ll-U-7-GH IJJ7DI$ J*TE-15*7*117 M117117 AMENDMENT 29 POWERHOUSE UNIT 3 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CONTROL ROD DRIVE HYDRAULIC SYSTEM MECHANICAL CONTROL DIAGRAM FIGURE 3.4-Sa SH+

PI 25-301 5-68 DI 85-68 ~ 1/2" DRAIN j y DRW CNDS & DMNRLZ WATER D-47E810-2-2, F4 ,->---*----1-, ZI-85-56 11-45E779-17, 13 ~--!-7 I [HS\\ I 85-56 co I lum\\' CRW I u'T'LI') I A~ ~ ~ l5.;3sJ CNDS & DMNRLZ WATER L l 0-47E61D-2-2. F4 '->----D'<l-----~_J 9-5 ~55-5A-2 I I CNDS & DMNRLZ WATER < 2-47E610-85-1, H7 25-21 I PS 5-1 ---,------------------------.!.-- ~----j D-45E783-4,D2 I I r----....J t©: 9-5 J_x.,(~ ~, 85-1A ~i I I

~

I 85-1 B L--i DRIVE WATER PUMP MOTOR MTR-85-1 85-6~ TE 85-62A ' TO PUMP 18 ,-----\\,GEARBOX DRAIN 7 t I I I I I I I I DRIVE WATER PUMP 1 A PMP-85-1 r

  • DI 85-69

~ STRAINER / ~~~ STN-85-707 1/2" DRAIN j ~ m ~-7 2-IL-85-2A I (Hs\\2-9-5 I ,--- 2-85-2A I -£" x-x-_j I SQ }!.{ SQ y DRW 25-21 I IL-85-2A PS I (Hs\\1 5 5-2 -r---- S5-2A I y lo-45E765-6,F5f---,-----------, I I r-r-T~-9-5 I 2-9-5 I 55-5A-23 I A55-5A-23 I I PA ~ 111~ I 85-2 I I I-I ~ -7

~*~ :

I IL-85-2C I (HS\\_ - - - - /4 (T?\\ I 85-2C 85-2 85-4A L ___ '::' ______ +---~ '~ 'I TO CCW DISCHARGE r---i1-47E610-24-2,C8 FROM PUMP 1 A L-.. GEAR BOX DRAIN,------ TE 85-628 DRIVE WATER "\\. "\\. / PUMP MOTOR MTR-85-2 PUMP 18 I UNIT 2 DRIVE WATER HEADER I< 2-47E610-85-1,D3..... t I I I I I I I DRIVE WATER PUMP 18 PMP-85-2 ~A~E~~bT~g(E~oo DRIVE (CRD) SYSTEM IS DESIGNED ro PROVIDE THE REACTOR WITH POSITIVE REACTIVITY CONTROL WHILE MAINTAINING A CONSTANT QUANTITY OF CONDENSATE TO THE REACTOR VESSEL IN THE FORM OF DRIVE SEAL LEAKAGE DRIVE COOLING, AND FLOW TO THE REACTOR VIA RWCU RETURN LINE. THE PUMP SUCTION IS FROM THE CONDENSATE STORAGE SYSTEt.t AND IS RAISED TO A PRESSURE ABOVE THE REACTOR OPERATING PRESSURE BY THE DRIVE WATER PUMPS. THE PRESSURE IS THEN REDUCED TO THE THREE PRESSURES NEEDED FOR DRIVING, CHARGING ANO COOLING. NOTES:

1. HYDRAULIC CONTROL UNIT (HCU) DEVICES AND CONTROL ROD DRIVE UNIT (CRDU)

DEVICES ARE SHOWN FOR A SINGLE UNIT AND ARE TYPICAL OF 185 SUCH UNITS. THE DRIVES ARE NUMBERED IN ACCORDANCE WITH TABLE 3 ON 1-730E321-4. UNIDS OF ALL COMPONENTS AFFILIATED WITH A PARTICULAR DRIVE WILL HAVE A SUFFIX THE SAME AS THE DRIVE COORDINATE, FOR EXAMPLE, THE UNID FOR FLOW CONTROL VALVE 398 ASSOCIATED WITH DRIVE 2-43 WOULD BE 1-FCV-85-398/243. AND FOR CYLINDER 718 WOULD BE 1-CYL-85-718/243.

2. UNITS 1 AND 2 SHARE THE SPARE DRIVE WATER PUMP [18) WHILE UNIT 3 HAS ITS OWN SPARE. EACH PUMP IS CAPABLE OF SUPP YI~G 100 GPM AT 1500 PSIG.
3. THE CRD HYDRAULIC SYSTEM PROVIDES CRD OPERATING FLUID, CRD COOLANT, ACCUMULATOR CHARGING AND EXHAUST WATER TO THE REACTOR.
4. THREE STAGES OF WATER PRESSURE ARE DERIVED BY TWO SEPARATE REGULATING SYSTEMS. THE SCRAt.t ACCUMULATOR CHARGING WATER IS AUTOMATICALLY REGULATED TO 1400 PSIG. THE FLOW CONTROL SYSTEM USING FCV-85-11A ORB AND FE-85-11 MAINTAINS APPROXIMATELY 65 GPM TO THE SYSTEM CRD DRIVE WATER IS MAINTAINED AT REACTOR PRESSURE. (Pr) + 250 TO 270 PSIG BY CONTROLLING PCV-85-23 AND THE AUTOMATIC CLOSING OF ~CV-85-20A OR 21A DURING ROD MOVEMENT. THE COOLING WATER HEADER PRESSURE IS APPROXIMATELY Pr+ 20 PSIG. SIXTY-FIVE GALLONS PER MINUTE (65 GPM)

FLOWS INTO THE REACTOR WHETHER OR NOT THE CONTROL RODS ARE MOVING DR AT REST.

5. EACH CRO IS EQUIPPED WITH A SEPARATE SCRAM ACCUMULATOR WHICH IS CHARGED WITH NITROGEN. ACCUt.tULATOR CHARGE PRESSURES ARE t.<<JNITORED BY LOCAL PRESSURE GAUGES PI-85-34/219 THRU 5843 AND PS-85-34/219 THRU 5843 WHICH ALARM ON LOW PRESSURE.

ACCUMULATOR PISTON INTEGRITY IS ALARMED WITH THE USE OF LS-85-34/219 THRU 5843.

6. CRD POSITIONING IS ACCOMPLISHED BY ELECTRICAL CONTROL OF THE INSERT VALVES FCV-85-40A/219 THRU 5843 AND FCV-85-40D/219 THRU 5843 OR THE WITHDRAWAL VALVES FCV-85-408/219 THRU 5843 AND FCV-85-40C/219 THRU 5843.
7. EACH CONTROL ROD. AS IT TRAVELS UP (INSERT) OR DOWN (WITHDRAW) PASSES A NUMBER OF SWITCHES. THE TOP TWO POSITION SWITCHES ZS-85-41A/219 THRU 5843 AND ZS-85-418/219 THRU 5843 ARE CALLED "OVER TRAVEL". THE BOTTOM TWO POSITION SWITCHES ARE "WITHDRAW BACKSEAT", ZS-85-42/219 THRU 5843 AND "WITHDRAW DISCONNECT". ZS-85-43/219 THRU 5843. THERE ARE 48 SWITCHES BETWEEN f~o5~E~!~1f~E'1ioB'ti~~6~~fD T~;YrB~t~ ARI f~~u"RtBloRI~HNeR~w~f~~~~~.(~il0 rHE EVEN NUMBERED SWITCHES ARE THE "LOCKED POSITION SWITCHES".

THE ABOVE SWITCHES ARE ACTUATED BY A MAGNET IN THE POSITION PROBE. THE ROD POSITION IS DISPLAYED IN THE MAIN CONTROL ROOM ON REACTOR PANEL 9-5.

8. INSTRUMENTATION ASSOCIATED WITH BACKUP CONTROLS IS LOCATED AS SHOWN ON THE DIAGRAM. IF A LOCATION IS NOT SHOWN, THE DEVICES WILL BE LOCATED ON THE APPROPRIATE 4160V AC BOARD. 480V AC BOARD OR 250V DC BOARD. (REF GE DESIGN SPEC 22A1470)
9. UNIDS ON DRAWING ARE FOR REFERENCE ONLY AND ARE ABBREVIATED AS SHOWN IN THE EXAMPLE TO MEET SPACE CONSTRAINTS. REFER TO MEL FOR COMPLETE UNIOS. ALL UNIDS ARE IN UNIT 1 UNLESS OTHERWISE NOTED. LEADING ZEROS SHOWN IN MEL AS PART Of THE UNID ARE NOT DEPICTED. FOR ADDITIONAL GUIDANCE REFER TO NEDP-4.

EXAMPLE: MEL UNID BFN-1-STN-085-0707 BFN-1-ZI-085-008A DRAWING UNIO STN-85-707 ZI-85-BA --If--+---------


*- -+------

PUMP 1A GEAR BOX GR-85-1 -- - --- ~------- - -+--+- GEAR BOX --+--+-

10. PARTIAL LOGIC FOR CONTROL ROD DRIVE SYSTEM IS SHOWN ON THE MECHANICAL LOGIC DIAGRAM LISTED IN REFERENCE DRAWINGS.

TE TE 85-38 85-3C y y I I I I I I ~ ~ TD RECIRCN PUMP A SEAL INJECTION TE 85-3D ~ 1-47EB17-1 AS rc-,._VH"XJ-1 T , r CRW 25-18 PI 85-9 8 TE 85-3E y I I I ~ 1A TE TE 82-3F 85-3G ~ y I I I ~ 5-18 PI 68-1051 ~ TE 85-3H ~ RAW COOLING WATER 11-47E610-24-1, ca ~>-----'-I--\\' TO PUt.tP 1B , GEAR BOX (1-47E844-2, C4) FI 68-1_9,53 r-(=:J11-47E1847-8 TO PIC-85-66 1........) 1-47E1610-85-2.F3 TO RECIRCN PUMP B SEAL INJECTION 1--!.Xl--t' .-.J---\\, 1-47E817-1, A2 , i, TE TE TE TE 85-58 y I I I ~ 85-48 85-4C

-&© ___ &_ili T T I

Zl-85-8B ZI-85-8C I I I (Hs\\ (Hs\\ I I I 85-88 85-8C ~ ~ I Y Y ~ ~ I j_ ___..J ~ I I,r--9 :,7 1-45E779-8,F3 I I vis\\ I r8~ I ....J ~ ZI-85-SA L - -* ij-~ ,!.. 7 5':~ IIL-85-a ____ _J~MCC 85-4D ~ ,---.,,....f.~>,To PIC-85-67 L.........r 1-47E1610-85-2,E3 25-188 TO DRIVE WATER HEADER --f1-47E1610-85-2,E5 l -1i& 9-5 25-18 ~ 9-5 85-16 LLD .._., 85-15A CRW ~ ,---,,,_-t:i:A tili,9 lt".,C)f. l -'..!.Jiv Zl --.,,~ 11AA (Fey\\,1 Yfil: Zl ' 25-18 T (FI\\_ 85~8 -i 8Y r---1~ I I I I .,l._25-18 9-19 ~-5 J..s2 5-18 (FT\\_ ________ @ _ (Fic\\ _(xs, 85-11 85-11C -8ec5~-711,...__._ 85-11 85-11A ...);;"( 11 AB L~ 25-1ae /PCv\\ 25-18 ~ PI c.,,-,,,,..7"-£~.>'<J'r-r,,~,P!f*q,,-"i 25-18,;-@19 FE FT FM 85-15 85-15 85-15 y @19 85-15 ~ 18 TE 85-4E y I I I ~ -Q GR-85-2 / .) TE TE TE TE 82-4F 85-4G 85-4H 85-6C ~ y ~ y I I I I I I ~ ~ RAW COOLING WATER TO PUMP 1 B GEAR ooxl-,-----~ CRO HYO STABIL '\\ TE TE 85-6F 85-SG y y I I I I I I ~ ~ TE 85-68 y I I I ~ REFERENCE DRAWINGS: MEL.................. CRD INSTRUMENT TABULATION 0-47W600-224&-224A... RPS-CRO CONTROL AIR PRESSURE PANELS 0-47E610-2-2......... CONTROL DIAGRAM-CONDENSATE 2-47E610-24-1D..,.... CONTROL DIAGRAM-RAW COOLING WATER 1-47E610-68-1........ CONTROL DIAGRAM-RECIRCULATION SYSTEM 1-47E610-69-1........ CONTROL DIAGRAM-RWCU SYSTEM 2-47E610-85-1........ CONTROL DIAGRAM-CRD HYO 1-47E610-85-2........ CONTROL DIAGRAM-CRD HYD 2-47E610-85-4........ CONTROL DIAGRAM-CR HYD 0-47E800-1........... FLOW DIAGRAM-GENERAL PLANT SYSTEMS 0-47E800-2........... MECHANICAL SYMBOLS & FLOW DIAGRAM DRAWING INDEX 0-47E847-1 THRU -3... FLOW DIAGRAM-CONTROL AIR 0-45E763-4........... 4160V UNIT AUX POWER SCHEMATIC DIAGRAM 2-45E779-7........... 480V SHUTDOWN AUX POWER 0-47E610-43-3........ MECHANICAL CONTROL DIAGRAM SAMPLING & WATER QUALITY SYSTEM GE DRAWINGS: 1-730E321-14......... REACTOR MANUAL CONTROL SYSTEM 1-791E201-2.-3....... CRO HYD INSTR SYSTEM SYMBOL: ~CONTROL AIR .,.---J!-5 SOL VL VS /FCV\\._-----,~---4 l-730E321-14 G71 85.AA ! 8~ - X I I ~X ~ I -~ I 85-208 ----~ ~ I rfcv\\_-! 85;:,;,),A I 'fl A I rx I I RETURN EXHAUST WATER .----<1-47E1610-85-2.E5 25-18 PI -~85-29 ~ 1 ~ 1 ------r7-771-45E779-8,F3 9-5 25-18 : -J.r'tcif : (FI\\ ~ Gii5 ~ I 85-JOA 85-308 ~85-50A 85-508 I --lS}1---1. ____.., .xt<t':t--,-' ---~ 25-18 -~ : FI FE 85-22 85-2 -r ___ r, G L_r_:::r~~ .,-.,.L_ 9-19 L - - l (,<s\\._ _ ~ lE!Ll I 85-50 85~c (PI\\ 85-21 B ....J 8t-~ ~-18 85-28 s 9_19 85-30 1 Y 6x\\ y I ...L 85-30 "'1 I (Fcv', ~ J..25-18 L 8~-~ __r.< (rT'\\ -~ 1-;,!!.(.MCC ' r 85-30 IL-85-50 25-18 Y. ~ t-----! FE '----------,e-------..--;,...1--~ 85-11 I 8~ © V: 0 ~-,-..i.i;r--"TJ.::~*i:><:lH¥-:i-1><1-1---'--'---.__,._~.><3-~~FE ~ 7' FULLY. -r, 85-30 DIS 85-10 y I ~-5 85-10 ~ ~ r-----t----7 ri-ki f'M5-18 ~-5 I 7 ~ 85-118 85-11A I I~ RWCU PUMP BEAR~ SEALS <1 47E610 85 4,A3 1 L--- M 85.::_ 1_!,8 ~--,,..,c~ r--W: 25-18B (rev\\ I ZI ~9-5(PI\\ 25-18 85-13A 85-138 y y I I +-----i--- 25-188 PT 85-13'---- 85-118 r-©: 11ee T.. 0--.Jiv Zl '-~ .. =#~J.,,.I I I~ 11BA J,.. I:::. ::1-! -W: 9-5 1 I ~-19/P?\\-19 85-13 85-13 ~ 85-13 ~ ~ PI 85-14 ~ 25-18 TO CHARGING WATER HEADER ~1-47E1610-85-2,F6 > 6 5 ~5-18 rss-*11, rl --;CV - R MCC OPEN-_.,...i;;::-----7 I ~;-23 IL-85-23 f,~;~--iQMCC I I~ 25-18 I 25-18 DT '--+-f*DI ):. 't,185-27 : ~ ~-~ r~ dti5(HS\\ ~ 85-!]' I 85-178 I~ !_____)';.:-{ 85-23A 85-238 L---->o"< 85-27 A 85-278 '>a<-J r----~ I 9-5 IM ~ L.=>_::{_ - -~---,1-45E779-7,B71 L _____ rp:_~ 85-17A ~ L --j1 -45E779-7, a1 I 25-18 25-18 9-19 9-19 DT FE ,--r:---,- 85-18 85-25 A-s ~ 5-18,.l._25-18 '-7 FT v-__ _ 85-25 mS 85-25 T 85-25 ~I~ lEQ.Ll {PD J'\\ (PX \\ 85-18A 85-188 85-18 ~ ~ ~ r9--5-----r;;_18 L£:.D 25-18 (FI\\ 85-25A ~ 85-258 25-18 ( PI ' (PI\\ 8~ TO COOLING WATER HEADER 8t°_!J._ ____ _;i;_-!1-47E1610-85-2,E6 4 RX VESSEL PRESSURE 1-47E610-68-1,A8 3 25-18 PI 85-31 ~ RWCU SYSTEM 1-47E610-69-1.H7 COMPANION DRAWINGS: 2-47E610-85-1 1-47E1610-85-2 AMENDMENT 28 REACTOR BUILDING UNIT 1 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CRD HYDRAULIC SYSTEM MECHANICAL CONTROL DIAGRAM FIGURE 3.4-8a SH 5 H G F E D C B A

AMENDMUH 22 BROWNS FERRY NUCLE AR PLANT FINAL SAFETY MiALYSIS REPORT CONTROL ROD HYDRAULIC SYSTEM A '"LOIi

AGR A M FIGURE 3.4-86

91ot1 Z-0Z83Lt'-Z r<t L9 lt[CIRCNJ~ 8 7 6 r-----------------7 5 I I I I I I I I I I I r-------------------------------------- I I ,,2.r[ST HCU CHARCINC~~c:e;::~======t~d'-------. 4 3 f"ORTAa.E ACCtllJLATOR N20WICIIG SYSTDI 8 ratTAa.E ACClUJI.ATOR NaawtCIIG SYSTDI A I. HIii CCIICRAL lllT[S AJIO IIU[IICIC[ W II NCS SC[ 0-ou20-,

2. IIOICW..... [Sl'OCl.,ICCl WATIEll[l'l.AClOIITHSTIIAIIICltfOIITESTINCAJIOfllJSHINC l. Al.l VALVES SHALL K l"~FIKEO 11TH UNIT 2 AHO SYS U IJHUSS NOTED AMENDMENT 27 POWERHOUSE UNIT 2 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT FLOW DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM FIGURE 3. 4-8c H

G F E D C B A

A.ME l,DMENT 22 BROWNS FERRY NUCLEAR PUNT FINAL SAFETY ANALYSIS REPORT CRO HYDRAULIC SYSTEM ~ECHA.N:CM CONTRO_ DlAGRAi.1

lZOH Z-OZ83lt-t Pl .l.11 G 10 11 12 i ,12* I o ~~.i-+-..::..~l "';,--+---"----t.1.......ta~ SCIIMl~ALYE CONTIIDLllllDDIIIVEUNIT !'l'll'ICAl.1UIIIITSI l'OITAa.t ACCIIU.ATOlt Na CHAKIIC SYSTEIII I HTDIWI.IC CONTIIOL UNIT CT'l'l'ICAl.1111Ull1111 !IEEIIITt:111 l'OlfTMILEACCt.llULATIIINaatAIICIICSYSTEIIA t----t,<i--,_:,_, SYSTEllll'IESS.-Tnl'DATA ~'Ii.~ ll'SIOJ ~~n IEEIIALELECTIICCO.DRAIIICS, ..**** PIPIIII-INITIIIM:Nlllo\\llRAII J-1JIEll1-4..**** ELDa:NTNll'DI-.. U,IC'IC!llootmlll.l, Ill:, DUl'IMIS1

  • -11111.......** fl.OSDIAIIRAII 10 AMENDMENT 29 POWERHOUSE UNIT 3 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CONTROL ROD DRIVE HYDRAULIC SYSTEM FLOW DIAGRAM FIGURE 3.4-Bo G

,b,;,,, l __ *~;*~~ ~,-1_-_-_-~-=-----=------=--.,__,-~~ . ff::f~~ I ! ;.... **~******~Iii

          • ~

i l~ = ~l~Jl;/='=l~Jl.... j~9=.c ! AMENDMENT 21

A B C D E F G H I J K 1 2 3 5 7 8 9 10 1 1 12 900" i;;- i;; 8 -O l 9 l 3 L v - l l'l L9 I 1-45E763-20,E8 f-----, I I 1-47E1 610-85-2,FS >--------, ZI-85-737 ~~i VENT,7 WI 25-613 VALVE _.J I I I I ~ z w > ARI SDV VENT VALVE r-----j I 1-45E763-19,G6 I ~--------< 1-47[1610-85-2 I Zl-85-736 I 25-416 FSV 85-736 w VENT I I I I I I FROM SCRAM OUTLET VALVE


~>iTcaY,_PI'cCcaA~L-< 1-47[1610-85-2,85 FOR 185

~ I I I I I I I ~l\\f---.....,~----'--. I I I I I I I I I I\\ I I I I I I I \\ I I I I 85-664 I I I I J $:-CV J 85-665 L.O~S-666 $:-,J ~CV J 85-82 [P D' 85-83A H 1,-_.,'J. ~ 1 _.,'a~:]----=f 1=---::-t1---1-:~6:::J"i-t1---1~~6:::]----I ZI-85-82AA~ I I,.,.


~ x1 x

i1lx11x I 9-5 >!<,.1,~i=as-82A

.li)!.(~9-5 r!-(~9-5 \\ - ~ 25-32 R) (G) ** 25-32 ! >{-{* }-~{~-~-fl-85-83AA fxs'\\_.,... *t-,-...!. t-..... - -..fxs\\__ - - - - - '::.. t-..... t--.... - - - - ~ ~S-:8 I T25-32 T25-32~W T 25-32 T ~ 0-1 ~2AB ~~2B i ZI$}}!. z~~::- 32 I @--+ ./"'cgL _ J TO FSV 85-36 I ~ (1-47E1610-85-2,F1 f-J UNITS ~;;,7 SCRAM DISCHARGE HEADER EAST ~ m ~ ~ ' ~ m ~ 0 ~ 1 I I 9-7 I ---+ 2B I I ~SCRAM DISCHARGE HEADER WEST SDIV VENT I RPS CHANNEL Al RPS CHANNEL 82 --------------------* f---- --------------,----,----7 N w. N ' ~ m 0 - w - w ~.. ' - ~ , 9-37 RPS...fHANNE!:._A2 ---,-----,------, 1_ LOG I SER I ~PS CHANNEL.JlL ~, 9-37 I I SOE0011 XR-55-1-1 I 7 LOG I SER I I 9-+0-27 I SOEOO IXR-55-1-31 I I 9-40-27 I I I I I I I ' ',-.L.---~- ~-. ----: 9-37 I I

  • I LOG SER I

,---t--7 [) I 1--t:xx:J-.J---kxx::f---l I 1 DEDO XR-55-1-41 1 9-37 I [ ~ 1 ~ ~ I 9-40-27 I SER I I I IXR-55-1-21 I w I 9-40-21 I I 9-91 L -@as LE L LS !$l LS _J LE _____ j -@s;91 ~91 LE 85-45J I ~-* SJ 2 85-458 85-458 85-45C 1.1.1 =i 85-45D I I 3 "J ~o "~ U>z -w o:, ~ =-~ ~<~ "'~"' Wt)z I I / 85-45A A LE s5;:.,5L I .., ____________ 7 ~91 ~L 9-6 @.r--~---, ~ lc~~o1I w 9-40-27

  • x I
  • x I

I I I I I I I I I I I I I I I I I I ~ "z o-w J< w ID~ 0 N ~ 0~ N rZ ~ ~~ ~ w WQ. ~ ~-.. 08 ' - ~w 4 5 w N w w N N N N ~ ~ m ~ w w ~ ~ ~ ~ "z o-J< ID~ 0 ~ Or ~z t)W <2 WQ. ~- ~ 00 ~w 6 SDIV VENT r--~---~----------------- ---------------=~~~~:::~~:~--t-@ r.-k-7 S~R 9-37 rl ------1---- --------r ---=------ RPS CHANNEL A1 -- 99 ~IXR-55-1-1331 ~ 1 T 9-37 RPS CHrANNEL~2 ___.... J = I

  • -----~--+-,, I SER I

9-4o-27 .... I 1-- I IXR-55-H311 I 1 ,I ~9-911 ----,


T9_,,-----e-7 I

~OG LS ~ ' 9-37 I SER I I J

1.

/ J 1. t- - OE10 ss-45H LOG 11 SER I 9_40_27 IXR-55-1-1321 I I 9_40_27 SOE10 IIXR-55-1341 ~1 L--------~ I 1 I I L---~ I 9-40-27 i 1 I I I I I I I /' LE L-, LS 85_:jSG ~5_:jSF LS J LE ___ j 85;J5E 85;J5H I l I l LE)c~ ------------7 a5,75" I -91 5" ~-91 f,_.LL-SS...,.. \\~_,, LE ~5K 85-45K I ~-* e,. ~ - I 9-6 @--+--, ~ lc:~021 8 9-40-27 7 m ~*-------------' ,===----t'\\f--,-tc'-}t-'--~..... -----1 25-32~ ~ )r.<; ~ 25-32 E>--- -, ZI-85-37E~ ~ >-r< }y(zI-85-37FB - ~


¢t- $ ~* tzi-a,;::jirA ___ ~

9-5 G R G ~ 9-5,- Zl-85-37EA ~l\\f--....,,.--' I I I 8 I I FCV I I FCV ~ I Le~7El I Le~7Fl L-e."'r'_ I L.~"'r'- I I I X X I i I I I I I I I I I I I I I I I 9 ~ "z o- - J< w ID~ 0 N ~ 0~ N ~z ~ uw ~ <:> w WQ. ~ ~-.. ~ ' 00 - ~w 10 REFERENCE DRAWINGS: BF-001, -002 A -008............ REACTOR CONTROLS INC. (CONTR 69C60-91121) 1-47E1610-85-1 A -2............ MECH CONTROL DIAGRAM CRD HYDRAULIC SYSTEM 1-47E852-2..................... FLOW DIAGRAM CLEAN RADWASTE A ECON DRAINAGE 1-47E820-6..................... FLOW DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM 1-47E605-28.................... MECHANICAL LAYOUT OF CONTROL BOARDS 1-730E915...................... RPS ELEM 1-730E321-SERIES............... RMCS ELEM 1-729E136-3.................... RPS IED NOTES:

1. THIS DRAWING SUPERSEDES 47W610-85-5 FOR UNIT 1.
2. SEE ANNUNCIATOR LEGEND DRAWING 1-47E610-55-14 (WINDOW 1).
3. SEE ANNUNCIATOR LEGEND DRAWING 1-13602649 SHT 14 (WINDOW 21).
4. FOR TEST CONNECTIONS TO SDIV INSTRUMENT LINES, SEE DETAIL 8199 ON DRAWING 0-471600-199.
5. LEADING ZEROS SHOWN IN MEL AS PART Of THE UNID ARE NOT DEPICTED. FOR ADDITIONAL GUIDANCE, REFER TO NEDP-4.

AMENDMENT REACTOR BUILDING UNIT 1 28 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT CRD MECHANICAL HYDRAULIC SYSTEM CONTROL DIAGRAM FIGURE 3.4-Bh A B C D E F G H

\\... I, Utt(U1.lR1UAUhl&LI" 1, l.~trw.t fl.T(t illC~ILT l,lllaM'\\UCtcC.l.11CWk.l 1.n*Ott,1,, ,._llUtl i.s1oP,1m:11 i, ~lUISIR~C $,COll{UWOCOUlll'lffOOf

t. tMlt1 "Cll~IIG,~.14.,11~*.wtn 111,,,,.1 I~. COtltT PIIIOll ll,llj 11, 1'lC(IJ>M,h1*-.M-t,Mflli'r,>

I:, IMH[IO~tl((S,1,J,UII 1J.rwSm011BIICATOllfll1Ct1ES*T11'1*1* II, l>YUU:;uoo11,1.... u1o U, 0,ITEIIT~lltll'>,rliltr'.....,lllit,...... ffl 11, tru1m1un ti, IIID(X1UU II, LIX-lk$8,l.!l(UTitlloMl It, H;T(U!LflSTOl'IEM.L'l!ll'.lrll'l'Clli 10.IKTUUl.flSfOIJl;ilhllCUTiJlo<<ll 11, E.tltklt,ILPlllOtleJ~tm:1 1'f.(.UllUl-lPll:o, 1tJll U. sru~EII 11, ccou~c,.1.ru otirrct !'. IIHn:-nnttff.l.1t.lN((I tl(01M' Ml1an:11o,....,u,u..i,.1kl1 1', l,'U*Sllll'IILliVALYE ti, kt,I CTCl'&\\1l~IHET1t1o-,.joi,,olloo1"1 ti, ftiTQl;.ACTUAT,lll,~Ulfl~tl-lll!IOII

'i. PIS1Dlltlt.1.ZCV91.l XI.Olilt*lll'lii-,l,l'IMfl.UCOI.UIJI.UI IAIIIIOMMl!Q ii, ~ U lNl'tl Jl.VJOOlll
!CII011~uoll ll. 'ffllOlll~~ICAtollPROlt

>lf'CSl~lr!IICAT0IC,1111,( 11.PlflOKTlllUUT

  • C,l'IC~(WIT)~C.\\I J1,o,*1HG10.U l&,1)111'1'!-fHl(ftTl'OATSll!HtWU I 11.DIH(Fl,,,l,IICt.,_,..,~,tllll,*lll"JCfl lit ~~~_!l~~!M1.M~.~llll 11.t:i1tw:*~rn,0tl~lU i.ur,o;1111t"wtu.a111'1 I. ~rtt.~~-al,Al m,mt11m 11 u.~rttn1~11 W, li0rol.T<<ltgtt,~"t1IJ<1'""I,

I!, nl[MtOIJ.L!l~1'\\lll,W1~1" ou10lfllll,lt 14,$\\'IIIJ(Plllflfil~l<MI

11. 1u1~,,MMrn u, sro, t1rt0ll M*w~n,"urr 11.r.o,rrm1r1t1L UiCll1'1Polll M,COlHTTIIICl~lf~1*

,i.eotmf'III S!.'-Cllh,>>."tl!'\\10 \\_ ~, =----* I IS IRC'#HS PERRY NUCLEAR PLANT FIHAL S.._Fl!TY.._NALYS!S Rf:PORT. Control Rod Ualt Orlv, - CUttwt,v IHUffl'l~on FIGUREU,9 AMENDMENT 16

2 - SEAL RrHG (INHER FILTER) 3

  • FLAT HEAD SCREW (0-RIHG SPAUR MOUNTING) 4
  • STRAINER 5 -

FLAT HEAD SCREW. 6 - DOWEL PIN )

  • 0-RJNG SPACtR 8
  • SPUD I CYLINDER 9
  • SOCKET *HE.AO CAP SCREW (RING FLA.~GE HOUHTING) 10 - SEAL CUP (PART OF OR!VE PISTON ASSEMBLY) 11
  • SEAL RING (BUFFER PI STON) 12
  • POSIT!ON IHOICATQR P~OBE IJ - FILLISTER-HEAO SCREW (POSJTIOH lHOICATOR PROBE HOUNTING)

H

  • LOC~WASHER (FQR PART 13) 15 - PISTON TUBE ASSEHSLY 16 - NUT (P!STOH TIJBE) 17
  • RING FLAHGE 18
  • 0-R!NG (PISTON TUBE )

19 - CYLINDER, TUBE, AND FLANGE 20

  • BALL ( CHECK VAL VE) 21 *
  • BALL RETAIHER 12
  • O*RING (BALL RETAINER) 13 -

COOLING WAHR ORIFICE 14

  • DRIVE PiSTON ASSEMBLY 25 - LOCKING BAND 26 - lMOEX TUBE 17 - SEAL RrNG (COLLET PISTON *

,HTERHAL) 18 - SEAL RING (COLLET PISTON

  • EXTERNAL) 19
  • COLLET I PISTON 30
  • BUFFrn SPR!tlG 31 -

C0LL£T SPRING '32

  • SPLIT BUSHING (STOP PJSTOH) 33 - STOP PISTON 34 - SEAL RING (STOP PISTON')

35

  • BARREL 36
  • NUT (STOP PISTON) 31
  • PLUG (GUIDE CAP) 38
  • F!LLlSTER*HEAO SCREW (GUIDE CAP PLUG MOUNTING) 39 - GU IDE CAP 40
  • DRILLED F ILLISTER-HEM SCREW (OUTER Fil TER MOUNTING) 41 - INNER FILTER 42
  • UNCOUPLING ROD 44 - LOCKING BAHO 45
  • OUTER FILTER 4~ : im~~ m:

0

PART OF ORlVE P ISTOH) 48 - PISTON COUPLING (PART OF DRIVE PISTON) 49 - MAGNET HOUSING (PART OF *oRtVE.

PISTON) so - LOCKIHG BAIIO (ON DRIVE PISTON! l 51 - COLLET HOUSING {PORTION OF OUTER TIJBE) 51 - NAMEPLATE 53

  • DRIVE SCREW 54 - LOCKING CUP 55
  • lHOEX TUBE NOTCH 56 - OUTER TUBE (PART Of C1LINOER, TUBE, A.~O FLANGE) 57 -

IHNER TUBE (PART OF CTllHOER, TUBE, ANO FLANGE) SB - THERIIOCQUPLE (PART OF POS!T!CH INDICATOR PROBE) 59 : BUFFER SHAFT 60

  • COLLET FINGER (PART OF COLLET RETAINER, ANO PISTON) 61 - INDICATOR TUBE (PART OF PISTON TUBE) 62 " LOCKING BAND (ON DRIVE PISTON) 63
  • INTERNAL BUSHING (DRIVE PISTON) 64 - EXTERNAL BUSH!nG (DRIVE P ISTOH) 65
  • OUTER SEALS (DRIVE PISTON) 66 - INSERT PORT ( INSERT & SCIW\\

INLET /WITHDRAW OUTLET) 61 - ~!HG MAGHET (PART OF nRIYE* PlSTGII) 68

  • CABLES (POSITION INDICATOR )

6S

  • PORT TO COLLET PISTON (WITHDRAW PRESSURE TO COLLET PISTON)

JO

  • WITHDRAW PORT (WITHDRAW INLET/

INSERT OUTLET & SCR.'J.i DISCHARGE) 71 - INNER SE,\\LS {DRIVE PISTON - DRIVE 00\\IN SEALS) 72

  • INNER SEALS (DRIV£ PISTON
  • DRIVE-UP SEALS) 73
  • WATER PORTS IN COLLET HOUSING 74
  • WATER PORTS IH COLLET PISTON 75 " VESSEL-WATER PORTS 76
  • SHOULDER (PART Of CYLINDER, TUBE AHO FLANGE) 17
  • BUFF!R ORIFICES IN PISTON TUBE ASSEMBLY 78
  • COLLET RETAINER ( HOLDS COLLET FINGERS) 79
  • POSlTIOH INDICATOR SW!TCHES 80 - BUFFER SHAFT PORTS BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT AMENDMENT 16 MODIFIED CONTROL. ROD DRIVE (BWR/61 FIGURE 3.4-9a L_ ____________

__i..______;...:..;;;.;;.;.~;.;;._---1, j

BFN-16 Figure 3.4-10 Deleted by Amendment 7.

BFN-22 Figure 3.4-11 (Deleted by Amendment 22)

0 () HANDLE BLADE NEUTRON ABSORBER RODS COUPLING RELEASE HANDLE VELOCITY LIMITER COUPLING SOCKET AMENDMENT 16 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANALYSIS REPORT Marathon Control Rod - Isometric FIGURE 3.4-12

ADMENDMENT 20 BROWNS FERRY NUCLEAR PLANT FINAL SAFETY ANAL YS!S REPORT WESTINGHOUSE CR-82M-l CONTROL ROD FIGURE 3.4-13}}