ML21285A146

From kanterella
Jump to navigation Jump to search
NRC-2021-000240 - Resp 1 - Final, Agency Records Subject to the Request Are Enclosed
ML21285A146
Person / Time
Issue date: 10/06/2021
From:
NRC/OCIO
To:
Shared Package
ML21285A143 List:
References
FOIA, NRC-2021-000240
Download: ML21285A146 (65)


Text

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS 11' REQUISITION NUMBER IPAG~

OF OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30 OIS-14-0030 I 55

2. CONTRACT NO.

13.AWARD/

14. ORDER NUMBER 15, SOLICITATION NUMBER
16. SOLICITATION NRC-HQ-10-14-E-0005 EFFECTIVE DATE ISSUE DATE
7.

FOR SOLICITATION l~~;;MA lb, TELEPHONE NUMBER (No collect calls) r* OFFER DUE DATE/LOCAL TIME INFORMATION CALL:

SHULER 301-287-3726 9.ISSUEDBY CODE INRCHQ

10. THIS ACQUISITION IS Ix UNRESTRICTED OR 7 SET ASIDE:

%FOR:

U S NRC -

HQ SMALL BUSI NESS WOMEN*OWNED SMALL BUSINESS 7 (WOSB) ELIGIBLE UNDER THE WOMEN-OWNED ACQUISITION MANAGEMENT DIVISION HUBZONE SMALL SMALL BUSINESS PROGRAM NAICS:541690 MAIL STOP 3WFN C64M P BUSINESS EDWOSB WASHINGTON DC 20555-0001 SERVICE-DISABLED B(A)

$6. 5 VETERAN-OWNED SIZE STANDARD:

SMALL BUSI NESS 11, DELIVERY FOR FOB DESTINA*

12. DISCOUNT TERMS 13b. RATING TION UNLESS BLOCK IS 13a. THIS CONTRACT IS A MARKED RATED ORDER UNDER OPAS (15 CFR 700) 14, METHOD OF SOLICITATION see SCHEDULE RFQ c.JIFB

~ RFP

15. DELIVER TO CODE I
16. ADMINISTERED BY CODE INRC HQ US NRC -

HQ ACQUISITION MANAGEMEN T DIVISION MAIL STOP 3WFN-05-C64MP WASHINGTON DC 20555- 0001 17a. CONTRACTOR/

CODE 831798702 I FACILITY !

18a. PAYMENT WILL BE MADE BY CODE IN RCPAYMENTS OFFEROR CODE QUALX CORPORATION U S NUCLEAR REGULATORY COMMISSION 6564 LOISDALE COURT SUITE 305 ONE WHITE FLINT NORTH SPRINGFIELD 11555 ROCKVILLE PIKE SPRINGFIELD VA 22150-1830 MAILSTOP 03-E17A ROCKVILLE M D 20852-2738 TELEPHONE NO.

~

17b. CHECK IF REMITTANCE IS DIFFERENT ANO PUT SUCH ADDRESS IN OFFER 18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW IS CHECKED I SEE ADDENDUM

19.
20.
21.
22.
23.
24.

ITEM NO.

SCHEDULE OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT The contractor shall provide Freedom o f Information Act(FOIA) Support Services as defined i n t he Statement of Work (SOW).

The overall minimum for this con tract is :

$10,00 0. 00 The minimum is guaranteed The overall maximum for this con tract is :

$ 11, 000, 000. 00 Accounting Info :

Period of Performance :

06/23/2014 to 06/2 2 /2019 Con t inued...

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA 126. TOTAL AWARD AMOUNT (For Govt. Use Only)

See schedule

$11, 000,000. 00 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED.

ADDENDA 7 ARE X ARE ARE NOT ATTACHED.

ARE NOT ATTACHED.

X 27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED.

ADDENDA

~ 28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

30a. SIGNATURE OF OFFEROR/CONTRACTOR 30b. NAME AND T ITLE OF SIGNER (Type or print)

AUTHORIZED FOR LOCAL REPRODUCTION PREVIOUS EDITION IS NOT USABLE 130c. DATE SIGNED

29. AWARD OF CONTRACT: REF.

OFFER DATED

. YOUR OFFER ON SOLICITATION (BLOCK 5),

INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

31a, UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER) 31b. NAME OF CONTRACTING OFFICER (Type or print) 1 31c. DATE SIGNED 06/20/201 4 JOSEPH L.

WIDDUP STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA* FAR (48 CFR) 53.212

2 o f 55

19.
20.
21.
22.
23.
24.

ITEM NO.

SCHEDULE OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 00001 EWC FOIA Servi ces Support Base Year : 06/23/2014 - 06/22/2015 Obligated Amount : $0. 00 10001 EWC FOIA Services Support 0. 00 Option Year 1: 06/23/2015 - 06/22/2016 Amount : $2, 200, 000. 00(0ption Line Item)

Ant icipated Exercise Date06/23/2015 20001 EWC FOIA Services Support 0. 00 Option Year 2 : 06/23/2016 - 06/22/2017 Amount : $2, 200, 000. 00 (0ption Line I t em)

Anticipated Exercise Date06/23/2016 30001 EWC FOIA Services Support 0. 00 Option Year 3 : 06/23/2017 -

06/22/2018 Amount : $2, 200, 000. 00 (0ption Line Item)

Anticipated Exercise Date06/23/2017 40001 EWC FOIA Services Support 0. 00 Option Year 4 : 06/23/2018 - 06/22/2019 Amount : $2, 200, 000. 00 (0ption Line Item)

Anticipated Exerci se Date06/23/2018 Continued...

32a. QUANTITY IN COLUMN 21 HAS BEEN i:--

RECEIVED INSPECTED ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED:

32b. SIGNATURE OF AUTHORIZED GOVERNMENT REPRESENTATIVE I32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 321. TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

33. SHIP NUMBER
34. VOUCHER NUMBER
35. AMOUNT VERIFIED
36. PAYMENT
37. CHECK NUMBER CORRECT FOR n COMPLETE PARTIAL

,., FINAL LJ PARTIAL FINAL

38. SIR ACCOUNT NUMBER
39. SIR VOUCHER NUMBER
40. PAID BY 41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT 42a. RECEIVED BY (Print/

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE 42b. RECEIVED AT (Location) 42c. DAT E REC'D {YYIMMIDD) 142d. TOTAL CONTAINERS STANDARD FORM 1449 (REV. 212012) BACK

REFERENCE NO. OF DOCUMENT BEING CONTINUED CONTINUATION SHEET NRC-HQ-lO-l4-E-0005 NAME OF OFFEROR OR CONTRACTOR QUALX CORPORATION ITEM NO.

(A)

SUPPLIES/SERVICES (B )

The obligated amount of award: $0. 00. The total for this award is shown in box 26.

NSN 7541).01-152,8067 QUANTITY UNIT (C )

( D)

UNIT PRICE (E )

PAGE OF 3

55 AMOUNT (F)

OPTIONAL FORM 336 (4-86)

Spo,nsored by GSA FAR (48 CFR) 53.110

N RC-HQ-10-14-E-0005 TABLE OF CONTENTS SECTION B - Supplies or Services/Prices......................................................................................... 5 SECTION C - Contract Clauses.......................................................................................................... 8 SECTION D - Attachments................................................................................................................ 52 Page 4 of 55

SECTION B - Supplies or Services/Prices B.1 BRIEF PROJECT TITLE AND WORK DESCRIPTION (AUG 2011)

(a) The title of this project is:

Freedom of Information Act (FOIA) Support Services (b) Summary work description:

NRC-HQ-10-14-E-0005 The contractor shall provide the necessary personnel, management, materials, administrative, and technical services necessary to perform the FOIA Support Services as defined in this Statement of Work (SOW).

B.2 MINIMUM GUARANTEE AND MAXIMUM VALUE OF THE IDIQ CONTRACT

. The maximum value of this IDIQ contract is $11,000,000.00. The minimum guarantee under this contract is

$10,000.00.

B.3 PRICE SCHEDULE CLIN 0001 - Base Year June 23, 2014 - June 22, 2015 Labor Category Team Leader & FOIA Analyst FOIA Analyst CLIN 1001 - Option Year 1 June 23, 2015 - June 22, 2016 Labor Category Team Leader & FOIA Analyst FOIA Analyst CLIN 2001 - Option Year 2 June 23, 2016-June 22, 2017 Team Leader & FOIA Anal st FOIA Anal st CLIN 3001 - Option Year 3 June 23, 2017 - June 22, 2018 Team Leader & FOIA Anal st FOIA Anal st CLIN 4001 - Option Year 4 June 23, 2018 - June 22, 2019 Team Leader & FOIA Anal st FOIA Anal st Hourlv Rate (b)(4)

Hourlv Rate (b)(4) ate Houri Rate (b}(4)

Houri (b)(4)

Page 5 of 55

NRC-HQ-10-14-E-0005 B.4 STATEMENT OF WORK B.4.1 Introduction The U.S. Nuclear Regulatory Commission (NRC) receives numerous requests for information under the record request provisions in the Freedom of Information and Privacy Acts. This includes differentiating sensitive or non-public information from information that may be released either without withholding or with partial withholding.

Some of the material requires handling of sensitive unclassified or classified information.

The contractor must possess the appropriate security clearances, facilities, handling and processing procedures for this material.

B.4.2

Background

Consistent with the NRC mission, in part, to license and regulate the Nation's civilian use of byproduct, source, and special nuclear materials while ensuring the adequate protection of public health and safety, and the environment, the NRC supports the U.S. Government's participation in international nuclear safety cooperation and assistance activities. These activities recently included NRC support for the Fukushima-Daiichi nuclear event that occurred following the Great East Japan Earthquake and Tsunami in 2011.

Stemming from NRC's involvement and heightened public interest in this matter, NRC has received numerous requests for information under the record request provisions of the Freedom of Information Act and Privacy Act.

The subject matter for verbatim reporting or captured in the electronic communications described are very complex, highly technical and in some instances involve the handling of classified or sensitive unclassified information, specifically as it pertains to nuclear reactor operation, spent fuel storage, accident mitigation, and decisions that have potential U.S. foreign policy implications.

B.4.3 Definitions The following definitions are used in this Statement of Work:

1. NRG Headquarters Operations Center: Event response command center located in one of the Commission offices at 11545 Rockville Pike, Rockville, MD
2. Verbatim Reporting: The typed reproduction of the exact words spoken by any individual captured on audio recordings.

B.4.4 Objectives The contractor shall provide the necessary personnel, management, materials, administrative, and technical services necessary to perform Freedom of Information Act (FOIA) Support Services as may be required in the Statement of Work.

B.4.5 Scope of Work Under one or more task orders issued under the resulting contract, the contractor may be required to:

Receive, review, analyze, and process Japan related FOIA/Privacy Act of 1974 requests in accordance with the FOIA, 5 U.S.C. 552, and the PA, 5 U.S.C. 552a; Differentiate sensitive or non-public information from information that can be released either without withholding, or with partial withholding in a timely manner.

Some of this material may require the Page 6 of 55

NRC-HQ-10-14-E-0005 handling of sensitive unclassified or classified information.

Appropriate security clearances, facilities, and handling and processing procedures for this material will be required.

Each task order statement of work will provide the specific requirements.

B.4.6 Meeting and Travel Required meetings and travel will be specified in each task order, as applicable.

B.4.7 Deliverables/Schedules and/or Milestones Required schedules and milestones will be specified in each task order, as applicable.

B.4.8 Government Furnished Equipment The Contractor shall provide services on-site (at NRC) only.

NRC will provide the Contractor with all necessary equipment to fulfill the requirements in task orders.

B.4.9 Government Furnished Materials The NRC will provide the Contractor with all available documentation, software manuals, diagnostic routines, and any other available information necessary to perform service under task orders issued under this contract.

All documentation provided to the Contractor will remain the property of the NRC.

B.4.10 Place of Performance U.S. Nuclear Regulatory Commission Headquarters Complex located in Rockville, Maryland.

B.4.11 Safety Standards The Contractor and all of its personnel shall adhere to Public Law 91-596, 1926.956, 1910.146 Occupational Safety and Health Administration (OSHA) standards, and Telecommunication Standard 29CFR 1910.268, as well as local government fire and safety regulations for the site while performing under task orders issued under this contract.

B.4.12 Recognized Holidays The NRC recognizes the holidays as stated below. The Contractor is not required to perform services under any task order under this contract on these holidays.

New Year's Day Martin Luther King Jr.'s Birthday President's Day Memorial Day Independence Day Labor Day Columbus Day Veteran's Day Thanksgiving Day Christmas Day Page 7 of 55

NRC-HQ-10-14-E-0005 SECTION C - Contract Clauses C.1 2052.215-71 CONTRACTING OFFICER REPRESENTATIVE (NOVEMBER 2006)

(a) The contracting officer's authorized representative, hereinafter referred to as the Contracting Officer's Representative (COR), for this contract is:

Name:

Email:

Phone:

Elizabeth Crawford, IS/PMPD/FPB Elizabeth.Crawford@nrc.gov 301-415-4044 (b) Performance of the work under this contract is subject to the technical direction of the COR. The term "technical direction" is defined to include the following:

(1) Technical direction to the contractor which shifts work emphasis between areas of work or tasks, authorizes travel which was unanticipated in the Schedule (i.e., travel not contemplated in the Statement of Work (SOW) or changes to specific travel identified in the SOW), fills in details, or otherwise serves to accomplish the contractual SOW.

(2) Provide advice and guidance to the contractor in the preparation of drawings, specifications, or technical portions of the work description.

(3) Review and, where required by the contract, approval of technical reports, drawings, specifications, and technical information to be delivered by the contractor to the Government under the contract.

(c) Technical direction must be within the general statement of work stated in the contract. The COR does not have the authority to and may not issue any technical direction which:

(1) Constitutes an assignment of work outside the general scope of the contract.

(2) Constitutes a change as defined in the "Changes" clause of this contract.

(3) In any way causes an increase or decrease in the total estimated contract cost, the fixed fee, if any, or the time required for contract performance.

( 4) Changes any of the expressed terms, conditions, or specifications of the contract.

(5) Terminates the contract, settles any claim or dispute arising under the contract, or issues any unilateral directive whatever.

(d) All technical directions must be issued in writing by the COR or must be confirmed by the COR in writing within ten (10) working days after verbal issuance. A copy of the written direction must be furnished to the Contracting Officer. A copy of NRC Form 445, Request for Approval of Official Foreign Travel, which has received final approval from the NRC must be furnished to the Contracting Officer.

(e) The contractor shall proceed promptly with the performance of technical directions duly issued by the COR in the manner prescribed by this clause and within the COR's authority under the provisions of this clause.

(f) If, in the opinion of the contractor, any instruction or direction issued by the COR is within one of the categories as defined in paragraph (c) of this section, the contractor may not proceed but shall notify the Contracting Officer in writing within five (5) working days after the receipt of any instruction or direction and Page 8 of 55

NRC-HQ-10-14-E-0005 shall request the Contracting Officer to modify the contract accordingly. Upon receiving the notification from the contractor, the Contracting Officer shall issue an appropriate contract modification or advise the contractor in writing that, in the Contracting Officer's opinion, the technical direction is within the scope of this article and does not constitute a change under the "Changes" clause.

(g) Any unauthorized commitment or direction issued by the COR may result in an unnecessary delay in the contractor's performance and may even result in the contractor expending funds for unallowable costs under the contract.

(h) A failure of the parties to agree upon the nature of the instruction or direction or upon the contract action to be taken with respect thereto is subject to 52.233-1 -Disputes.

(i) In addition to providing technical direction as defined in paragraph (b) of the section, the COR shall:

(1) Monitor the contractor's technical progress, including surveillance and assessment of performance, and recommend to the contracting officer changes in requirements.

(2) Assist the contractor in the resolution of technical problems encountered during performance.

(3) Review all costs requested for reimbursement by the contractor and submit to the Contracting Officer recommendations for approval, disapproval, or suspension of payment for supplies and services required under this contract.

(4) Assist the contractor in obtaining the badges for the contractor personnel.

(5) Immediately notify the Security Branch, Division of Facillities and Security (SB/DFS) (via e-mail) when a contractor employee no longer requires access authorization and return of any NRC issued badge to SB/DFS within three days after their termination.

(6) Ensure that all contractor employees that require access to classified Restricted Data or National Security Information or matter, access to sensitive unclassified information (Safeguards, Official Use Only, and Proprietary information) access to sensitive IT systems or data, unescorted access to NRC controlled buildings/space, or unescorted access to protected and vital areas of nuclear power plants receive approval of SB/DFS prior to access in accordance with Management Directive and Handbook 12.3.

(7) For contracts for the design, development, maintenance or operation of Privacy Act Systems of Records, obtain from the contractor as part of closeout procedures, written certification that the contractor has returned to NRC, transferred to the successor contractor, or destroyed at the end of the contract in accordance with instructions provided by the NRC Systems Manager for Privacy Act Systems of Records, all records (electronic or paper) which were created, compiled, obtained or maintained under the contract.

C.2 2052.204-70 SECURITY a) Security/Classification Requirements Form. The attached NRC Form 187 (See Section D for List of Attachments) furnishes the basis for providing security and classification requirements to prime contractors, subcontractors, or others (e.g., bidders) who have or may have an NRC contractual relationship that requires access to classified information or matter, access on a continuing basis (in excess of 90 or more days) to NRC Headquarters controlled buildings, or otherwise requires NRC photo identification or card-key badges.

(b) It is the contractor's duty to safeguard National Security Information, Restricted Data, and Formerly Restricted Data. The contractor shall, in accordance with the Commission's security regulations and requirements, be responsible for safeguarding National Security Information, Restricted Data, and Formerly Page 9 of 55

NRC-HQ-10-14-E-0005 Restricted Data, and for protecting against sabotage, espionage, loss, and theft, the classified documents and material in the contractor's possession in connection with the performance of work under this contract. Except as otherwise expressly provided in this contract, the contractor shall, upon completion or termination of this contract, transmit to the Commission any classified matter in the possession of the contractor or any person under the contractor's control in connection with performance of this contract. If retention by the contractor of any classified matter is required after the completion or termination of the contract and the retention is approved by the contracting officer, the contractor shall complete a certificate of possession to be furnished to the Commission specifying the classified matter to be retained. The certification must identify the items and types or categories of matter retained, the conditions governing the retention of the matter and their period of retention, if known. If the retention is approved by the contracting officer, the security provisions of the contract continue to be applicable to the matter retained.

(c) In connection with the performance of the work under this contract, the contractor may be furnished, or may develop or acquire, proprietary data (trade secrets) or confidential or privileged technical, business, or financial information, including Commission plans, policies, reports, financial plans, internal data protected by the Privacy Act of 1974 (Pub. L.93-579), or other information which has not been released to the public or has been determined by the Commission to be otherwise exempt from disclosure to the public. The contractor agrees to hold the information in confidence and not to directly or indirectly duplicate, disseminate, or disclose the information in whole or in part to any other person or organization except as may be necessary to perform the work under this contract. The contractor agrees to return the information to the Commission or otherwise dispose of it at the direction of the contracting officer. Failure to comply with this clause is grounds for termination of this contract.

(d) Regulations. The contractor agrees to conform to all security regulations and requirements of the Commission which are subject to change as directed by the NRC Division of Security and the Contracting Officer. These changes will be under the authority of the changes clause.

(e) Definition of National Security Information. The term National Security Information, as used in this clause, means information that has been determined pursuant to Executive Order 12356 or any predecessor order to require protection against unauthorized disclosure and that is so designated.

(f) Definition of Restricted Data. The term Restricted Data, as used in this clause, means all data concerning:

(1) design, manufacture, or utilization of atomic weapons; (2) the production of special nuclear material; or (3) the use of special nuclear material in the production of energy, but does not include data declassified or removed from the Restricted Data category pursuant to section 142 of the Atomic Energy Act of 1954, as amended.

(g) Definition of Formerly Restricted Data. The term Formerly Restricted Data, as used in this clause, means all data removed from the Restricted Data category under section 142-d of the Atomic Energy Act of 1954, as amended.

(h) Security clearance personnel. The contractor may not permit any individual to have access to Restricted Data, Formerly Restricted Data, or other classified information, except in accordance with the Atomic Energy Act of 1954, as amended, and the Commission's regulations or requirements applicable to the particular type or category of classified information to which access is required. The contractor shall also execute a Standard Form 312, Classified Information Nondisclosure Agreement, when access to classified information is required.

Page 10 of 55

NRC-HQ-10-14-E-0005 (i) Criminal liabilities. It is understood that disclosure of National Security Information, Restricted Data, and Formerly Restricted Data, relating to the work or services ordered hereunder to any person not entitled to receive it, or failure to safeguard any Restricted Data, Formerly Restricted Data, or any other classified matter that may come to the contractor or any person under the contractor's control in connection with work under this contract, may subject the contractor, its agents, employees, or subcontractors to criminal liability under the laws of the United States. (See the Atomic Energy Act of 1954, as amended, 42 U.S.C. 2011 et seq.; 18 U.S.C. 793 and 794; and Executive Order 12356.)

0) Subcontracts and purchase orders. Except as otherwise authorized in writing by the contracting officer, the contractor shall insert provisions similar to the foregoing in all subcontracts and purchase orders under this contract.

(k) In performing the contract work, the contractor shall classify all documents, material, and equipment originated or generated by the contractor in accordance with guidance issued by the Commission. Every subcontract and purchase order issued hereunder involving the origination or generation of classified documents, material, and equipment must provide that the subcontractor or supplier assign classification to all documents, material, and equipment in accordance with guidance furnished by the contractor.

C.3 2052.204-71 SITE ACCESS BADGE REQUIREMENT During the life of this contract, the rights of ingress and egress for contractor personnel must be made available as required. In this regard,. all contractor personnel whose duties under this contract require their presence on-site shall be clearly identifiable by a distinctive badge furnished by the Government. The Contracting Officer Representative shall assist the contractor in obtaining the badges for the contractor personnel. It is the sole responsibility of the contractor to ensure that each employee has proper identification at all times. All prescribed identification must be immediately delivered to the Security Office for cancellation or disposition upon the termination of employment of any contractor personnel. Contractor personnel must have this identification in their possession during on-site performance under this contract. It is the contractor's duty to assure that contractor personnel enter only those work areas necessary for performance of contract work, and to assure the safeguarding of any Government records or data that contractor personnel may come into contact with.

C.4 SECURITY REQUIREMENTS FOR BUILDING ACCESS APPROVAL (AUG 2011)

The Contractor shall ensure that all its employees, subcontractor employees or consultants who are assigned to perform the work herein for contract performance for periods of more than 30 calendar days at NRC facilities, are approved by the NRC for unescorted NRC buiilding access.

The Contractor shall conduct a preliminary federal facilities security screening interview or review for each of its employees, subcontractor employees, and consultants and submit to the NRC only the names of candidates for contract performance that have a reasonable probability of obtaining approval necessary for access to NRC's federal facilities. The Contractor shall pre-screen its applicants for the following:

(a) felony arrest in the last seven (7) years; (b) alcohol related arrest within the last five (5) years; (c) record of any military courts-martial convictions in the past ten (10) years; (d) illegal use of narcotics or other controlled substances possession in the past year, or illegal purchase, production, transfer, or distribution of narcotics or other controlled substances in the last seven (7) years; and (e) delinquency on any federal debts or bankruptcy in the last seven (7) years.

The Contractor shall make a written record of its pre-screening interview or review (including any information to mitigate the responses to items listed in (a) - (e)), and have the applicant verify the pre-screening record or review, sign and date it. Two (2) copies of the pre-screening signed record or review Page 11 of 55

NRC-HQ-10-14-E-0005 shall be supplied to the Division of Facilities and Security, Personnel Security Branch (DFS/PSB) with the Contractor employee's completed building access application package.

The Contractor shall further ensure that its employees, any subcontractor employees and consultants complete all building access security applications required by this clause within fourteen (14) calendar days of notification by DFS/PSB of initiation of the application process.

Timely receipt of properly completed records of the Contractor's signed pre-screening record or review and building access security applications (submitted for candidates that have a reasonable probability of obtaining the level of access authorization necessary for access to NRC's facilities) is a contract requirement.

Failure of the Contractor to comply with this contract administration requirement may be a basis to cancel the award, or terminate the contract for default, or offset from the contract's invoiced cost or price the NRC's incurred costs or delays as a result of inadequate pre-screening by the Contractor.

In the event of cancellation or termination, the NRC may select another firm for contract award.

A Contractor, subcontractor employee or consultant shall not have access to NRC facilities until he/she is approved by DFS/PSB. Temporary access may be approved based on a favorable NRC review and discretionary determination of their building access security forms. Final building access will be approved based on favorably adjudicated checks by the Government. However, temporary access approval will be revoked and the Contractor's employee may subsequently be denied access in the event the employee's investigation cannot be favorably determined by the NRC.

Such employee will not be authorized to work under any NRC contract requiring building access without the approval of DFS/PSB. When an individual receives final access, the individual will be subject to a review or reinvestigation every five (5) or ten (10) years, depending on their job responsibilities at the NRC.

The Government shall have and exercise full and complete control and discretion over granting, denying, withholding, or terminating building access approvals for individuals performing work under this contract.

Individuals performing work under this contract at NRC facilities for a period of more than 30 calendar days shall be required to complete and submit to the Contractor representative an acceptable OPM Standard Form 85 (Questionnaire for Non-Sensitive Positions), and two (2) FD 258 (Fingerprint Charts).

Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Emplloyment Authorization Card, or other official documentation issued by the U.S. Citizenship and Immigration Services.

Any applicant with less than five (5) years residency in the U.S. will not be approved for building access. The Contractor shall submit the documents to the NRC Contracting Officer's Representative (COR) who will give them to DFS/PSB.

DFS/PSB may, among other things, grant or deny temporary unescorted building access approval to an individual based upon its review of the information contained in the OPM Standard Form 85 and the Contractor's pre-screening record. Also, in the exercise of its authority, the Government may, among other things, grant or deny permanent building access approval based on the results of its review or investigation.

This submittal requirement also applies to the officers of the firm who, for any reason, may visit the NRC work sites for an extended period of time during the term of the contract.

In the event that DFS/ PSS are unable to grant a temporary or permanent building access approval, to any individual performing work under this contract, the Contractor is responsible for assigning another individual to perform the necessary function without any delay in the contract's performance schedule, or without adverse impact to any other terms or conditions of the contract.

The Contractor is responsible for informing those affected by this procedure of the required building access approval process (i.e., temporary and permanent determinations), and the possibility that individuals may be required to wait until permanent building access approvals are granted before beginning work in NRC's buildings.

CANCELLATION OR TERMINATION OF BUILDING ACCESS/ REQUEST Page 12 of 55

NRC-HQ-10-14-E-0005 The Contractor shall immediately notify the PO when a Contractor or subcontractor employee or consultant's need for NRG building access approval is withdrawn or the need by the Contractor employee's for building access terminates.

The PO will immediately notify DFS/PSB (via e-mail} when a Contractor employee no longer requires building access. The Contractor shall be required to return any NRG issued badges to the Contracting Officer's Representative (COR) for return to DFS/FSB (Facilities Security Branch) within three (3) days after their termination.

C.5 SECURITY REQUIREMENTS FOR INFORMATION TECHNOLOGY LEVEL I OR LEVEL II ACCESS APPROVAL (AUG 2011)

The contractor must identify all individuals selected to work under this contract. The NRG Contracting Officer's Representative (COR) shall make the final determination of the level, if any, of IT access approval required for all individuals working under this contract/order using the following guidance. The Government shall have full and complete control and discretion over granting, denying, withholding, or terminating IT access approvals for contractor personnel performing work under this contract/order.

The contractor shall conduct a preliminary security interview or review for each employee requiring IT level I or II access and submit to the Government only the names of candidates that have a reasonable probability of obtaining the level of IT access approval for which the employee has been proposed. The contractor shall pre-screen its applicants for the following:

(a) felony arrest in the last seven (7) years; (b) alcohol related arrest within the last five (5) years; (c) record of any military courts-martial convictions in the past ten (10) years; (d) illegal use of narcotics or other controlled substances possession in the past year, or illegal purchase, production, transfer, or distribution of narcotics or other controlled substances in the last seven (7) years; and (e) delinquency on any federal debts or bankruptcy in the last seven (7) years.

The contractor shall make a written record of its pre-screening interview or review (including any information to mitigate the responses to items listed in (a) - (e)), and have the employee verify the pre-screening record or review, sign and date it. The contractor shall supply two (2) copies of the signed contractor's pre-screening record or review to the NRG Contracting Officer's Representative (COR), who will then provide them to the NRC Office of Administration, Division of Facilities and Security, Personnel Security Branch with the employee's completed IT access application package.

The contractor shall further ensure that its personnel complete all IT access approval security applications required by this clause within fourteen (14) calendar days of notification by the NRG Contracting Officer's Representative (COR) of initiation of the application process.

Timely receipt of properly completed records of the pre-screening record and IT access approval applications (submitted for candidates that have a reasonable probability of obtaining the level of security assurance necessary for access to NRC's IT systems/data) is a requirement of this contract/order.

Failure of the contractor to comply with this requirement may be a basis to terminate the contract/order for cause, or offset from the contract's invoiced cost or price the NRC's incurred costs or delays as a result of inadequate pre-screening by the contractor.

SECURITY REQUIREMENTS FOR IT LEVEL I Performance under this contract/order will involve contractor personnel who perform services requiring direct access to or operate agency sensitive information technology systems or data (IT Level I).

The IT Level I involves responsibility for the planning, direction, and implementation of a computer security program; major responsibility for the direction, planning, and design of a computer system, including hardware and software; or the capability to access a computer system during its operation or maintenance in such a way that could cause or that has a relatively high risk of causing grave damage; or the capability to realize a significant personal gain from computer access.

Page 13 of 55

NRC-HQ-10-14-E-0005 Contractor personnel shall not have access to sensitive information technology systems or data until they are approved by DFS/PSB and they have been so informed in writing by the NRC Contracting Officer's Representative (COR). Temporary IT access may be approved by DFS/PSB based on a favorable review or adjudication of their security forms and checks.

Final IT access may be approved by DFS/PSB based on a favorably review or adjudication of a completed background investigation. However, temporary access authorization approval will be revoked and the employee may subsequently be denied IT access in the event the employee's investigation cannot be favorably adjudicated.

Such an employee will not be authorized to work under any NRC contract/order requiring IT access without the approval of DFS/PSB, as communicated in writing to the contractor by the NRC Contracting Officer's Representative (COR). Where temporary access authorization has been revoked or denied by DFS/PSB, the contractor shall assign another contractor employee to perform the necessary work under this contract/ order without delay to the contract/order performance schedule, or without adverse impact to any other terms or conditions of the contract/order.

When an individual receives final IT access approval from DFS/PSB, the individual will be subject to a reinvestigation every ten (10) years thereafter (assuming continuous performance under contract/order at NRC) or more frequently in the event of noncontinuous performance under contract/order at NRC.

The contractor shall submit a completed security forms packet, including the OPM Standard Form (SF) 86 (Questionnaire for National Security Positions), two (2) copies of the Contractor's signed pre-screening record and two (2) FD 258 fingerprint charts, to the NRC PO who will then provide them to DFS/PSB for review and adjudication, prior to the individual being authorized to perform work under this contract/order requiring access to sensitive information technology systems or data. Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Employment Authorization Card, or other official documentation issued by the U.S.

Citizenship and Immigration Services. Any applicant with less tlhan seven (7) years residency in the U.S. will not be approved for IT Level I access. The Contractor shall submit the documents to the NRC Contracting Officer's Representative (COR) who will give them to DFS/PSB. The contractor shall ensure that all forms are accurate, complete, and legible. Based on DFS/PSB review of the contractor employee's security forms and/or the receipt of adverse information by NRC, the contractor individual may be denied access to NRC facilities and sensitive information technology systems or data until a final determination is made by DFS/PSB and thereafter communicated to the contractor by the NRC Contracting Officer's Representative (COR) regarding the contractor person's eligibility.

In accordance with NRCAR 2052.204-70 "Security," IT Level I contractors shall be subject to the attached NRC Form 187 and SF-86 which furnishes the basis for providing security requirements to contractors that have or may have an NRC contractual relationship which requires access to or operation of agency sensitive information technology systems or r,emote development and/or analysis of sensitive information technology systems or data or other access to such systems and data; access on a continuing basis (in excess more than 30 calendar days) to NRC buildings; or otherwise requires issuance of an unescorted NRC badge.

SECURITY REQUIREMENTS FOR IT LEVEL II Performance under this contract/order will involve contractor personnel that develop and/or analyze sensitive information technology systems or data or otherwise have access to such systems or data (IT Level II).

The IT Level II involves responsibility for the planning, design, operation, or maintenance of a computer system and all other computer or IT positions.

Contractor personnel shall not have access to sensitive information technology systems or data until they are approved by DFS/PSB and they have been so informed in writing by the NRC Contracting Officer's Representative (COR). Temporary access may be approved by DFS/PSB based on a favorable review of their Page 14 of 55

NRC-HQ-10-14-E-0005 security forms and checks.

Final IT access may be approved by DFS/PSB based on a favorably adjudication.

However, temporary access authorization approval will be revoked and the contractor employee may subsequently be denied IT access in the event the employee's investigation cannot be favorably adjudicated.

Such an employee will not be authorized to work under any NRC contract/order requiring IT access without the approval of DFS/PSB, as communicated in writing to the contractor by the NRC Contracting Officer's Representative (COR).

Where temporary access authorization has been revoked or denied lby DFS/PSB, the contractor is responsible for assigning another contractor employee to perform the necessary work under this contract/order without delay to the contract/order performance schedule, or without adverse impact to any other terms or conditions of the contract/order.

When a contractor employee receives final IT access approval from DFS/PSB, the individual will be subject to a review or reinvestigation every ten (10) years (assuming continuous performance under contract/order at NRC) or more frequently in the event of noncontinuous performance under contract/order at NRC.

The contractor shall submit a completed security forms packet, including the OPM Standard Form (SF) 86 (Questionnaire for National Security Positions), two (2) copies of the Contractor's signed pre-screening record and two (2) FD 258 fingerprint charts, through the NRC Contractiing Officer's Representative (COR) to DFS/PSB for review and adjudication, prior to the contractor employee being authorized to perform work under this contract/order. Non-U.S. citizens must provide official documentation to the DFS/PSB, as proof of their legal residency. This documentation can be a Permanent Resident Card, Temporary Work Visa, Employment Authorization Card, or other official documentation issued by the U.S. Citizenship and Immigration Services.

Any applicant with less than seven (7) years residency in the U.S. will not be approved for IT Level II access.

The Contractor shall submit the documents to the NRC Contracting Officer's Representative (COR) who will give them to DFS/PSB.

The contractor shall ensure that all forms are accurate, complete, and legible.

Based on DFS/ PSB review of the contractor employee's security forms and/or the receipt of adverse information by NRC, the contractor employee may be denied access to NRC facilities, sensitive information technology systems or data until a final determination is made by DFS/PSB regarding the contractor person's eligibility.

In accordance with NRCAR 2052.204-70 "Security," IT Level II contractors shall be subject to the attached NRC Form 187, SF-86, and contractor's record of the pre-screening which furnishes the basis for providing security requirements to contractors that have or may have an NRC contractual relationship which requires access to or operation of agency sensitive information technology systems or remote development and/or analysis of sensitive information technology systems or data or other access to such systems or data; access on a continuing basis ( in excess of more than 30 calendar days) to NRC buildings; or otherwise requires issuance of an unescorted NRC badge.

CANCELLATION OR TERMINATION OF IT ACCESS/REQUEST When a request for IT access is to be withdrawn or canceled, the contractor shall immediately notify the NRC Contracting Officer's Representative (COR) by telephone so that the access review may be promptly discontinued. The notification shall contain the full name of the contractor employee and the date of the request. Telephone notifications must be promptly confirmed by the contractor in writing to the NRC Contracting Officer's Representative (COR), who will forward the confirmation to DFS/PSB. Additionally, the contractor shall immediately notify the NRC Contracting Officer's Representative (COR) in writing, who will in turn notify DFS/PSB, when a contractor employee no longer requires access to NRC sensitive automated information technology systems or data, including the voluntary or involuntary separation of employment of a contractor employee who has been approved for or is being processed for IT access.

The contractor shall flow the requirements of this clause down into all subcontracts and agreements with consultants for work that requires them to access NRC IT resources.

C.6 PERIOD OF PERFORMANCE (AUG 2011) AL TERNA TE IV (AUG 2011)

Page 15 of 55

NRC-HQ-10-14-E-0005 The ordering period for this contract shall commence on April 1, 2013, and will expire on March 31, 2014.

Any orders issued during this period shall be completed within the time specified in the order, unless otherwise specified herein. (See 52.216 Ordering.) The term of this contract may be extended at the option of the Government for an additional four (4) one-year periods.

C.7 AUTHORITY TO USE GOVERNMENT PROVIDED SPACE AT NRC HEADQUARTERS (AUG 2011)

Prior to occupying any government provided space at NRG HQs in Rockville Maryland, the Contractor shall obtain written authorization to occupy specifically designated government space, via the NRC Contracting Officer's Representative (COR), from the Chief, Space Design Branch, ADSPC.

Failure to obtain this prior authorization can result in one, or a combination, of the following remedies as deemed appropriate by the Contracting Officer.

(1)

Rental charge for the space occupied will be deducted from the invoice amount due the Contractor (2) Removal from the space occupied (3) Contract Termination Page 16 of 55

NRC-HQ-10-14-E-0005 C.8 ELECTRONIC PAYMENT (AUG 2011)

The Debt Collection Improvement Act of 1996 requires that all payments except IRS tax refunds be made by Electronic Funds Transfer. Payment shall be made in accordance with FAR 52.232-33, entitled "Payment by Electronic Funds-Central Contractor Registration".

To receive payment, the contractor shall prepare invoices in accordance with NRC's Billing Instructions.

Claims shall be submitted on the payee's letterhead, invoice, or on the Government's Standard Form 1034, "Public Voucher for Purchases and Services Other than Personal," and Standard Form 1035, "Public Voucher for Purchases Other than Personal - Continuation Sheet." The preferred method of submitting invoices is electronically to the Department of the Interior at NRCPayments_NBCDenver@nbc.gov.

If the contractor submits a hard copy of the invoice, it shall be submitted to the following address:

Department of the Interior National Business Center Attn: Fiscal Services Branch - D2770 7301 West Mansfield Avenue Denver, CO 80235-2230 C.9 DENIAL OF FEDERAL BENEFITS TO INDIVIDUALS CONVICTED OF DRUG TRAFFICKING OR POSSESSION (AUG 2011)

In the event that an award is made to an individual, Section 5301 of the Anti-Drug Abuse Act of 1988 (P.L.

100-690), codified at 21 U.S.C. 862, authorizes denial of Federal benefits such as grants, contracts, purchase orders, financial aid, and business and professional licenses to individuals convicted of drug trafficking or possession.

C.10 ANNUAL AND FINAL CONTRACTOR PERFORMANCE EVALUATIONS (AUG 201*1)

Annual and final evaluations of contractor performance under this contract will be prepared in accordance with FAR Subpart 42.15, "Contractor Performance Information," normally at or near the time the contractor is notified of the NRC's intent to exercise the contract option.

If the multi-year contract does not have option years, then an annual evaluation will be prepared (state time for annual evaluation).

Final evaluations of contractor performance will be prepared at the expiration of the contract during the contract closeout process.

The Contracting Officer will transmit the NRC Contracting Officer's Representative's (COR) annual and final contractor performance evaluations to the contractor's Project Manager, unless otherwise instructed by the contractor. The contractor will be permitted thirty days to review the document and submit comments, rebutting statements, or additional information.

Where a contractor concurs with, or takes no exception to an annual performance evaluation, the Contracting Officer will consider such evaluation final and releasable for source selection purposes.

Disagreements between the parties regarding a performance evaluation will be referred to an individual one level above the Contracting Officer, whose decision will be final.

The Contracting Officer will send a copy of the completed evaluation report, marked "Source Selection Information", to the contractor's Project Manager for their records as soon as practicable after it has been finalized.

The completed evaluation report also will be used as a tool to improve communications between the NRC and the contractor and to improve contract performance.

Page 17 of 55

NRC-HQ-10-14-E-0005 The completed annual performance evaluation will be used to support future award decisions in accordance with FAR 42.1502 and 42.1503. During the period the information is being used to provide source selection information, the completed annual performance evaluation will be released to only two parties - the Federal government personnel performing the source selection evaluation and the contractor under evaluation if the contractor does not have a copy of the report already.

C.11 NRC INFORMATION TECHNOLOGY SECURITY TRAINING (AUG 2011)

NRC contractors shall ensure that their employees, consultants, and subcontractors with access to the agency's information technology (IT) equipment and/or IT services complete NRC's online initial and refresher IT security training requirements to ensure that their knowledge of IT threats, vulnerabilities, and associated countermeasures remains current.

Both the initial and refresher IT security training courses generally last an hour or less and can be taken during the employee's regularly scheduled work day.

Contractor employees, consultants, and subcontractors shall complete the NRC's online annual, "Computer Security Awareness" course on the same day that they receive access to the agency's IT equipment and/or services, as their first action using the equipment/service. For tlhose contractor employees, consultants.and subcontractors who are already working under this contract, the on-line training must be completed in accordance with agency Network Announcements issued throughout the year, within three weeks of issuance of this modification.

Contractor employees, consultants, and subcontractors who have been granted access to NRG information technology equipment and/or IT services must continue to take IT security refresher training offered online by the NRG throughout the term of the contract.

Contractor employees will receive notice of NRC's on line IT security refresher training requirements through agency-wide notices.

The NRG reserves the right to deny or withdraw Contractor use or access to NRG IT equipment and/or services, and/or take other appropriate contract administrative actions (e.g., disallow costs, terminate for cause) should the Contractor violate the Contractor's responsibility under this clause.

C.12 COMPLIANCE WITH U.S. IMMIGRATION LAWS AND REGULATIONS (AUG 2011)

NRC contractors are responsible to ensure that their alien personnel are not in violation of United States immigration laws and regulations, including employment authorization documents and visa requirements.

Each alien employee of the Contractor must be lawfully admitted for permanent residence as evidenced by Permanent Resident Form 1-551 (Green Card), or must present other evidence from the U.S. Department of Homeland Security/U.S. Citizenship and Immigration Services that employment will not affect his/her immigration status.

The U.S. Citizenship and Immigration Services provides information to contractors to help them understand the employment eligibility verification process for non-US citizens.

This information can be found on their website, http://www.uscis.gov/ portal/site/uscis.

The NRG reserves the right to deny or withdraw Contractor use or access to NRG facilities or its equipment/services, and/or take any number of contract administrative actions (e.g., disallow costs, terminate for cause) should the Contractor violate the Contractor's responsibility under this clause.

C.13 SAFETY OF ON-SITE CONTRACTOR PERSONNEL (AUG 2011)

Ensuring the safety of occupants of Federal buildings is a responsibility shared by the professionals implementing our security and safety programs and the persons being protected. The NRC's Office of Administration (ADM) Division of Facilities and Security (DFS) has coordinated an Occupant Emergency Plan (OEP) for NRG Headquarters buildings with local authorities. Tlhe OEP has been approved by the Page 18 of 55

NRC-HQ-10-14-E-0005 Montgomery County Fire and Rescue Service.

It is designed to improve building occupants' chances of survival, minimize damage to property, and promptly account for building occupants when necessary.

The contractor's Project Director shall ensure that all personnel working full time on-site at NRC Headquarters read the NRC's OEP, provided electronically on the NRC Intranet at http://www.internal.nrc.gov/ADM/OEP.pdf.

The contractor's Project Director also shall emphasize to each staff member that they are to be familiar with and guided by the OEP, as well as by instructions given by emergency response personnel in situations which pose an immediate health or safety threat to building occupants.

The NRC Contracting Officer's Representative (COR) shall ensure that the contractor's Project Director has communicated the requirement for on-site contractor staff to follow the guidance in the OEP. The NRC Contracting Officer's Representative (COR) also will assist in accounting for on-site contract persons in the event of a major emergency (e.g., explosion occurs and casualties or injuries are suspected) during which a full evacuation will be required, including the assembly and accountability of occupants.

The NRC DFS will conduct drills periodically to train occupants and assess these procedures.

C.14 TASK ORDER PROCEDURES These procedures apply to any task order that is issued after the first task order, which is being competed as part of this solicitation.

(a) Task order request for proposal. When a requirement within the scope of work for this contract is identified, the contracting officer shall transmit to the contractor a Task Order Request for Proposal (TORFP) which may include the following, as appropriate:

(1) Scope of work/meetings/travel and deliverables; (2) Reporting requirements; (3) Period of performance - place of performance; (4) Applicable special provisions; (5) Technical skills required; and (6) Estimated level of effort.

(b) Task order technical proposal.

By the date specified in the TORFP, the contractor shall deliver to the contracting officer a written or verbal (as specified in the TORFP technical proposal submittal instructions) technical proposal that provides the technical information required by the TORFP.

(c) Cost/price proposal. The contractor's cost proposal for each task order must be fully supported by cost/price information adequate to establish the reasonableness of the proposed amounts.

(d) Task order award.

The contractor shall perform all work described in definitized task orders issued by the contracting officer.

Definitized task orders include the following:

(1) Statement of work/meetings/travel and deliverables; (2) Reporting requirements; Page 19 of 55

NRC-HQ-10-14-E-0005 (3) Period of performance; (4) Key personnel; (5) Applicable special provisions; and (6) Total task order amount.

C.18 2052.216-73 ACCELERATED TASK ORDER PROCEDURES (JAN 1993)

(a) The NRC may require the contractor to begin work before receiving a definitized task order from the contracting officer. Accordingly, when the contracting officer verbally authorizes the work, the contractor shall proceed with performance of the task order subject to the monetary limitation established for the task order by the contracting officer.

(b) When this accelerated procedure is employed by the NRC, the contractor agrees to begin promptly negotiating with the contracting officer the terms of the definitive task order and agrees to submit a cost proposal with supporting cost or pricing data. If agreement on a definitized task order is not reached by the target date mutually agreed upon by the contractor and contracting officer, the contracting officer may determine a reasonable price and/or fee in accordance with Subpart 15.8 and Part 31 of the FAR, subject to contractor appeal as provided in 52..233-1, Disputes. In any event, the contractor shall proceed with completion of the task order, subject only to the monetary limitation established by the contracting officer and the terms and conditions of the basic contract.

C.19 52.212-4 CONTRACT TERMS AND CONDITIONS--COMMERCIAL ITEMS (FEB 2012)

(a) Inspection/Acceptance. The Contractor shall only tender for acceptance those items that conform to the requirements of this contract. The Government reserves the right to inspect or test any supplies or services that have been tendered for acceptance. The Government may require repair or replacement of nonconforming supplies or reperformance of nonconforming services at no increase in contract price. If repair/replacement or reperformance will not correct the defects or is not possible, the Government may seek an equitable price reduction or adequate consideration for acceptance of nonconforming supplies or services. The Government must exercise its post-acceptance rights-(1) Within a reasonable time after the defect was discovered or should have been discovered; and (2) Before any substantial change occurs in the condition of the item, unless the change is due to the defect in the item.

(b) Assignment. The Contractor or its assignee may assign its rights to receive payment due as a result of performance of this contract to a bank, trust company, or other financing institution, including any Federal lending agency in accordance with the Assignment of Claims Act (31 U.S.C. 3727). However, when a third party makes payment (e.g., use of the Governmentwide commercial purchase card), the Contractor may not assign its rights to receive payment under this contract.

(c) Changes. Changes in the terms and conditions of this contract may be made only by written agreement of the parties.

(d) Disputes. This contract is subject to the Contract Disputes Act of 1978, as amended (41 U.S.C. 601-613). Failure of the parties to this contract to reach agreement on any request for equitable adjustment, claim, appeal or action arising under or relating to this contract shall be a dispute to be resolved in accordance with Page 20 of 55

NRC-HQ-10-14-E-0005 the clause at FAR 52.233-1, Disputes, which is incorporated herein by reference. The Contractor shall proceed diligently with performance of this contract, pending final resolution of any dispute arising under the contract.

(e) Definitions. The clause at FAR 52.202-1, Definitions, is incorporated herein by reference.

(f) Excusable delays. The Contractor shall be liable for default unless nonperformance is caused by an occurrence beyond the reasonable control of the Contractor and without its fault or negligence such as, acts of God or the public enemy, acts of the Government in either its sovereign or contractual capacity, fires, floods, epidemics, quarantine restrictions, strikes, unusually severe weather, and delays of common carriers. The Contractor shall notify the Contracting Officer in writing as soon as it is reasonably possible after the commencement of any excusable delay, setting forth the full particulars in connection therewith, shall remedy such occurrence with all reasonable dispatch, and shall promptly give written notice to the Contracting Officer of the cessation of such occurrence..

(g) Invoice.

(1) The Contractor shall submit an original invoice and three copies(or electronic invoice, if authorized) to the address designated in the contract to receive invoices. An invoice must include-(i) Name and address of the Contractor; (ii) Invoice date and number; (iii) Contract number, contract line item number and, if applicable, the order number; (iv) Description, quantity, unit of measure, unit price and extended price of the items delivered; (v) Shipping number and date of shipment, including the bill of lading number and weight of shipment if shipped on Government bill of lading; (vi) Terms of any discount for prompt payment offered; (vii) Name and address of official to whom payment is to be sent; (viii) Name, title, and phone number of person to notify in event of defective invoice; and (ix) Taxpayer Identification Number (TIN). The Contractor shall include its TIN on the invoice only if required elsewhere in this contract.

(x) Electronic funds transfer (EFT) banking information.

(A) The Contractor shall include EFT banking informatiion on the invoice only if required elsewhere in this contract.

(B) If EFT banking information is not required to be on the invoice, in order for the invoice to be a proper invoice, the Contractor shall have submitted correct EFT banking information in accordance with the applicable solicitation provision, contract clause (e.g., 52.232-33, Payment by Electronic Funds Transfer--

Central Contractor Registration, or 52.232-34, Payment by Electronic Funds Transfer--Other Than Central Contractor Registration), or applicable agency procedures.

(C) EFT banking information is not required if the Government waived the requirement to pay by EFT.

Page 21 of 55

NRC-HQ-10-14-E-0005 (2) Invoices will be handled in accordance with the Prompt Payment Act (31 U.S.C. 3903) and Office of Management and Budget (0MB) prompt payment regulations at 5 CFR part 1315.

(h) Patent indemnity. The Contractor shall indemnify the Government and its officers, employees and agents against liability, including costs, for actual or alleged direct or contributory infringement of, or inducement to infringe, any United States or foreign patent, trademark or copyright, arising out of the performance of this contract, provided the Contractor is reasonably notified of such claims and proceedings.

(i) Payment.-

(1) Items accepted. Payment shall be made for items accepted by the Government that have been delivered to the delivery destinations set forth in this contract.

(2) Prompt payment. The Government will make payment in accordance with the Prompt Payment Act (31 U.S.C. 3903) and prompt payment regulations at 5 CFR part 1315.

(3) Electronic Funds Transfer (EFT). If the Government makes payment by EFT, see 52.212-5(b) for the appropriate EFT clause.

(4) Discount. In connection with any discount offered for early payment, time shall be computed from the date of the invoice. For the purpose of computing the discount earned, payment shall be considered to have been made on the date which appears on the payment check or the specified payment date if an electronic funds transfer payment is made.

(5) Overpayments. If the Contractor becomes aware of a duplicate contract financing or invoice payment or that the Government has otherwise overpaid on a contract financing or invoice payment, the Contractor shall--

(i) Remit the overpayment amount to the payment office cited in the contract along with a description of the overpayment including the--

(A) Circumstances of the overpayment (e.g., duplicate payment, erroneous payment, liquidation errors, date(s) of overpayment);

(B) Affected contract number and delivery order number, if applicable; (C) Affected contract line item or subline item, if applicable; and (D) Contractor point of contact.

(ii) Provide a copy of the remittance and supporting documentation to the Contracting Officer.

(6) Interest.

(i) All amounts that become payable by the Contractor to the Government under this contract shall bear simple interest from the date due until paid unless paid within 30 days of becoming due. The interest rate shall be the interest rate established by the Secretary of the Treasury as provided in Section 611 of the Contract Disputes Act of 1978 (Public Law 95-563), which is applicable to the period in which the amount becomes due, as provided in (i)(6)(v) of this clause, and then at the rate applicable for each six-month period as fixed by the Secretary until the amount is paid.

Page 22 of 55

NRC-HQ-10-14-E-0005 (ii) The Government may issue a demand for payment to the Contractor upon finding a debt is due under the contract.

(iii) Final decisions. The Contracting Officer will issue a final decision as required by 33.211 if--

(A) The Contracting Officer and the Contractor are unable to reach agreement on the existence or amount of a debt within 30 days; (B) The Contractor fails to liquidate a debt previously demanded by the Contracting Officer within the timeline specified in the demand for payment unless the amounts were not repaid because the Contractor has requested an installment payment agreement; or (C) The Contractor requests a deferment of collection on a debt previously demanded by the Contracting Officer (see 32.607-2).

(iv) If a demand for payment was previously issued for the debt, the demand for payment included in the final decision shall identify the same due date as the original demand for payment.

(v) Amounts shall be due at the earliest of the following dates:

(A) The date fixed under this contract.

(B) The date of the first written demand for payment, including any demand for payment resulting from a default termination.

(vi) The interest charge shall be computed for the actual number of calendar days involved beginning on the due date and ending on--

(A) The date on which the designated office receives payment from the Contractor; (B) The date of issuance of a Government check to the Contractor from which an amount otherwise payable has been withheld as a credit against the contract debt; or (C) The date on which an amount withheld and applied to the contract debt would otherwise have become payable to the Contractor.

(vii) The interest charge made under this clause may be reduced under the procedures prescribed in 32.608-2 of the Federal Acquisition Regulation in effect on the date of this contract.

U) Risk of loss. Unless the contract specifically provides otherwise, risk of loss or damage to the supplies provided under this contract shall remain with the Contractor until, and shall pass to the Government upon:

(1) Delivery of the supplies to a carrier, if transportation is f.o.b. origin; or (2) Delivery of the supplies to the Government at the destination specified in the contract, if transportation is f.o.b. destination.

(k) Taxes. The contract price includes all applicable Federal, State, and local taxes and duties.

(I) Termination for the Government's convenience. The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. In the event of such termination, the Contractor shall immediately stop all work hereunder and shall immediately cause any and all of its suppliers and Page 23 of 55

NRC-HQ-10-14-E-0005 subcontractors to cease work. Subject to the terms of this contract, the Contractor shall be paid a percentage of the contract price reflecting the percentage of the work performed prior to the notice of termination, plus reasonable charges the Contractor can demonstrate to the satisfaction of the Government using its standard record keeping system, have resulted from the termination. The Contractor shall not be required to comply with the cost accounting standards or contract cost principles for this purpose. This paragraph does not give the Government any right to audit the Contractor's records. The Contractor shall not be paid for any work performed or costs incurred which reasonably could have been avoided.

(m) Termination for cause. The Government may terminate this contract, or any part hereof, for cause in the event of any default by the Contractor, or if the Contractor fails to comply with any contract terms and conditions, or fails to provide the Government, upon request, with adequate assurances of future performance.

In the event of termination for cause, the Government shall not be liable to the Contractor for any amount for supplies or services not accepted, and the Contractor shall be liable to the Government for any and all rights and remedies provided by law. If it is determined that the Government improperly terminated this contract for default, such termination shall be deemed a termination for convenience.

(n) Title. Unless specified elsewhere in this contract, title to items furnished under this contract shall pass to the Government upon acceptance, regardless of when or where the Government takes physical possession.

(o) Warranty. The Contractor warrants and implies that the items delivered hereunder are merchantable and fit for use for the particular purpose described in this contract.

(p) Limitation of liability. Except as otherwise provided by an express warranty, the Contractor will not be liable to the Government for consequential damages resulting from any defect or deficiencies in accepted items.

(q) Other compliances. The Contractor shall comply with all applicable Federal, State and local laws, executive orders, rules and regulations applicable to its performance under this contract.

(r) Compliance with laws unique to Government contracts. The Contractor agrees to comply with 31 U.S.C.

1352 relating to limitations on the use of appropriated funds to influence certain Federal contracts; 18 U.S.C.

431 relating to officials not to benefit; 40 U.S.C. 3701, et seq., Contract Work Hours and Safety Standards Act; 41 U.S.C. 51-58, Anti-Kickback Act of 1986; 41 U.S.C. 265 and 110 U.S.C. 2409 relating to whistleblower protections; 49 U.S.C. 40118, Fly American; and 41 U.S.C. 423 relating to procurement integrity.

(s) Order of precedence. Any inconsistencies in this solicitation or contract shall be resolved by giving precedence in the following order:

(1) The schedule of supplies/services.

(2) The Assignments, Disputes, Payments, Invoice, Other Compliances, and Compliance with Laws Unique to Government Contracts paragraphs of this clause.

(3) The clause at 52.212-5.

(4) Addenda to this solicitation or contract, including any license agreements for computer software.

(5) Solicitation provisions if this is a solicitation.

(6) Other paragraphs of this clause.

(7) The Standard Form 1449.

Page 24 of 55

(8) Other documents, exhibits, and attachments (9) The specification.

(t) Central Contractor Registration (CCR).

NRC-HQ-10-14-E-0005 (1) Unless exempted by an addendum to this contract, the Contractor is responsible during performance and through final payment of any contract for the accuracy and completeness of the data within the CCR database, and for any liability resulting from the Government's reliance on inaccurate or incomplete data. To remain registered in the CCR database after the initial registration, the Contractor is required to review and update on an annual basis from the date of initial registration or subsequent updates its information in the CCR database to ensure it is current, accurate and complete. Updating information in the CCR does not alter the terms and conditions of this contract and is not a substitute for a properly executed contractual document.

(2)(i) If a Contractor has legally changed its business name, "doing business as" name, or division name (whichever is shown on the contract), or has transferred the assets used in performing the contract, but has not completed the necessary requirements regarding novation and change-of-name agreements iin FAR subpart 42.12, the Contractor shall provide the responsible Contracting Officer a minimum of one business day's written notification of its intention to (A) change the name in the CCR database; (B) comply with the requirements of subpart 42.12; and (C) agree in writing to the timeline and procedures specified by the responsible Contracting Officer. The Contractor must provide with the notification sufficient documentation to support the legally changed name.

(ii) If the Contractor fails to comply with the requirements of paragraph (t)(2)(i) of this clause, or fails to perform the agreement at paragraph (t)(2)(i)(C) of this clause, and, in the absence of a properly executed novation or change-of-name agreement, the CCR information that shows the Contractor to be other than the Contractor indicated in the contract will be considered to be incorrect information within the meaning of the "Suspension of Payment" paragraph of the electronic funds transfer (EFT) clause of this contract.

(3) The Contractor shall not change the name or address for EFT payments or manual payments, as appropriate, in the CCR record to reflect an assignee for the purpose of assignment of claims (see Subpart 32.8, Assignment of Claims). Assignees shall be separately registered in the CCR database. Information provided to the Contractor's CCR record that indicates payments, including those made by EFT, to an ultimate recipient other than that Contractor will be considered to be incorrect information within the meaning of the "Suspension of payment" paragraph of the EFT clause of this contract.

(4) Offerors and Contractors may obtain information on registration and annual confirmation requirements via CCR accessed through https://www.acquisition.gov or by calling 1-888-227-2423 or 269-961-5757.

C.20 52.212-4 CONTRACT TERMS AND CONDITIONS--COMMERCIAL ITEMS (FEB 2012)

AL TERNA TE I (AUG 2012)

(a) Inspection/Acceptance.

(1) The Government has the right to inspect and test all materials furnished and services performed under this contract, to the extent practicable at all places and times, including the period of performance, and in any event before acceptance. The Government may also inspect the plant or plants of the Contractor or any subcontractor engaged in contract performance. The Government will perform inspections and tests in a manner that will not unduly delay the work.

Page 25 of 55

NRC-HQ-10-14-E-0005 (2) If the Government performs inspection or tests on the premises of the Contractor or a subcontractor, the Contractor shall furnish and shall require subcontractors to furnish all reasonable facilities and assistance for the safe and convenient performance of these duties.

(3) Unless otherwise specified in the contract, the Government will accept or reject services and materials at the place of delivery as promptly as practicable after delivery, and they will be presumed accepted 60 days after the date of delivery, unless accepted earlier.

(4) At any time during contract performance, but not later than 6 months (or such other time as may be specified in the contract) after acceptance of the services or materials last delivered under this contract, the Government may require the Contractor to replace or correct services or materials that at time of delivery failed to meet contract requirements. Except as otherwise specified in paragraph (a)(6) of this clause, the cost of replacement or correction shall be determined under paragraph (i) of this clause, but the "hourly rate" for labor hours incurred in the replacement or correction shall be reduced to exclude that portion of the rate attributable to profit. Unless otherwise specified below, the portion of the "hourly rate" attributable to profit shall be 10 percent. The Contractor shall not tender for acceptance materials and services required to be replaced or corrected without disclosing the former requirement for replacement or correction, and, when required, shall disclose the corrective action taken. [Insert portion of labor rate attributable to profit.]

(5)(i) If the Contractor fails to proceed with reasonable promptness to perform required replacement or correction, and if the replacement or correction can be performed within the ceiling price (or the ceiling price as increased by the Government), the Government may--

(A) By contract or otherwise, perform the replacement or correction, charge to the Contractor any increased cost, or deduct such increased cost from any amounts paid or due under this contract; or (B) Terminate this contract for cause.

(ii) Failure to agree to the amount of increased cost to be charged to the Contractor shall be a dispute under the Disputes clause of the contract.

(6) Notwithstanding paragraphs (a)(4) and (5) above, the Government may at any time require the Contractor to remedy by correction or replacement, without cost to the Government, any failure by the Contractor to comply with the requir,ements of this contract, if the failure is due to--

(i) Fraud, lack of good faith, or willful misconduct on the part of the Contractor's managerial personnel; or (ii) The conduct of one or more of the Contractor's employees selected or retained by the Contractor after any of the Contractor's managerial personnel has reasonable grounds to believe that the employee is habitually careless or unqualified.

(7) This clause applies in the same manner and to the same extent to corrected or replacement materials or services as to materials and services originally delivered under this contract.

(8) The Contractor has no obligation or liability under this contract to correct or replace materials and services that at time of delivery do not meet contract requirements, except as provided in this clause or as may be otherwise specified in the contract.

(9) Unless otherwise specified in the contract, the Contractor's obligation to correct or replace Government-furnished property shall be governed by the clause pertaining to Government property.

Page 26 of 55

NRC-HQ-10-14-E-0005 (b) Assignment. The Contractor or its assignee may assign its rights to receive payment due as a result of performance of this contract to a bank, trust company, or other financing institution, including any Federal lending agency in accordance with the Assignment of Claims Act (31 U.S.C. 3727). However, when a third party makes payment (e.g., use of the Governmentwide commercial purchase card), the Contractor may not assign its rights to receive payment under this contract.

(c) Changes. Changes in the terms and conditions of this contract may be made only by written agreement of the parties.

(d) Disputes. This contract is subject to the Contract Disputes Act of 1978, as amended (41 U.S.C. 601-613). Failure of the parties to this contract to reach agreement on any request for equitable adjustment, claim, appeal or action arising under or relating to this contract shall be a dispute to be resolved in accordance with the clause at FAR 52.233-1, Disputes, which is incorporated herein by reference. The Contractor shall proceed diligently with performance of this contract, pending final resolution of any dispute arising under the contract.

(e) Definitions.

(1) The clause at FAR 52.202-1, Definitions, is incorporated herein by reference. As used in this clause--

(i) Direct materials means those materials that enter directly into the end product, or that are used or consumed directly in connection with the furnishing of the end product or service.

(ii) Hourly rate means the rate(s) prescribed in the contract for payment for labor that meets the labor category qualifications of a labor category specified in the contract that are--

(A) Performed by the contractor; (B) Performed by the subcontractors; or (C) Transferred between divisions, subsidiaries, or affilliates of the contractor under a common control.

(iii) Materials means--

(A) Direct materials, including supplies transferred between divisions, subsidiaries, or affiliates of the contractor under a common control; (B) Subcontracts for supplies and incidental services for which there is not a labor category specified in the contract; (C) Other direct costs (e.g., incidental services for which there is not a labor category specified in the contract, travel, computer usage charges, etc.);

(D) The following subcontracts for services which are specifically excluded from the hourly rate:

[Insert any subcontracts for services to be excluded from the hourly rates prescribed in the schedule.]; and (E) Indirect costs specifically provided for in this clause.

(iv) Subcontract means any contract, as defined in FAR Subpart 2.1, entered into with a subcontractor to furnish supplies or services for performance of the prime contract or a subcontract including transfers between divisions, subsidiaries, or affiliates of a contractor or subcontractor. It includes, but is not limited to, purchase orders, and changes and modifications to purchase orders.

Page 27 of 55

NRC-HQ-10-14-E-0005 (f) Excusable delays. The Contractor shall be liable for default unless nonperformance is caused by an occurrence beyond the reasonable control of the Contractor and without its fault or negligence such as, acts of God or the public enemy, acts of the Government in either its sovereign or contractual capacity, fires, floods, epidemics, quarantine restrictions, strikes, unusually severe weather, and delays of common carriers. The Contractor shall notify the Contracting Officer in writing as soon as it is reasonably possible after the commencement of any excusable delay, setting forth the full particulars in connection therewith, shall remedy such occurrence with all reasonable dispatch, and shall promptly give written notice to the Contracting Officer of the cessation of such occurrence..

(g) Invoice.

(1) The Contractor shall submit an original invoice and three copies(or electronic invoice, if authorized) to the address designated in the contract to receive invoices. An invoice must include-(i) Name and address of the Contractor; (ii) Invoice date and number; (iii) Contract number, contract line item number and, if applicable, the order number; (iv) Description, quantity, unit of measure, unit price and extended price of the items delivered; (v) Shipping number and date of shipment, including the bill of lading number and weight of shipment if shipped on Government bill of lading; (vi) Terms of any discount for prompt payment offered; (vii) Name and address of official to whom payment is to be sent; (viii) Name, title, and phone number of person to notify in event of defective invoice; and (ix) Taxpayer Identification Number (TIN). The Contractor shall include its TIN on the invoice only if required elsewhere in this contract.

(x) Electronic funds transfer (EFT) banking information.

(A) The Contractor shall include EFT banking informatiion on the invoice only if required elsewhere in this contract.

(B) If EFT banking information is not required to be on the invoice, in order for the invoice to be a proper invoice, the Contractor shall have submitted correct EFT banking information in accordance with the applicable solicitation provision, contract clause (e.g., 52.232-33, Payment by Electronic Funds Transfer--

Central Contractor Registration, or 52.232-34, Payment by Electronic Funds Transfer--Other Than Central Contractor Registration), or applicable agency procedures.

(C) EFT banking information is not required if the Government waived the requirement to pay by EFT.

(2) Invoices will be handled in accordance with the Prompt Payment Act (31 U.S.C. 3903) and Office of Management and Budget (0MB) prompt payment regulations at 5 CFR part 1315.

Page 28 of 55

NRC-HQ-10-14-E-0005 (h) Patent indemnity. The Contractor shall indemnify the Government and its officers, employees and agents against liability, including costs, for actual or alleged direct or contributory infringement of, or inducement to infringe, any United States or foreign patent, trademark or copyright, arising out of the performance of this contract, provided the Contractor is reasonably notified of such claims and proceedings.

(i) Payments.

(1) Work performed. The Government will pay the Contractor as follows upon the submission of commercial invoices approved by the Contracting Officer:

(i) Hourly rate.

(A) The amounts shall be computed by multiplying the appropriate hourly rates prescribed in the contract by the number of direct labor hours performed. Fractional parts of an hour shall be payable on a prorated basis.

(B) The rates shall be paid for all labor performed on the contract that meets the labor qualifications specified in the contract. Labor hours incurred to perform tasks for which labor qualifications were specified in the contract will not be paid to the extent the work is performed by individuals that do not meet the qualifications specified in the contract, unless specifically authorized by the Contracting Officer.

(C) Invoices may be submitted once each month (or at more frequent intervals, if approved by the Contracting Officer) to the Contracting Officer or the authorized representative.

(D) When requested by the Contracting Officer or the authorized representative, the Contractor shall substantiate invoices (including any subcontractor hours reimbursed at the hourly rate in the schedule) by evidence of actual payment, individual daily job timecards, records that verify the employees meet the qualifications for the labor categories specified in the contract, or other substantiation specified in the contract.

(E) Unless the Schedule prescribes otherwise, the hourly rates in the Schedule shall not be varied by virtue of the Contractor having performed work on an overtime basis.

(1) If no overtime rates are provided in the Schedule and the Contracting Officer approves overtime work in advance, overtime rates shall be negotiated.

(2) Failure to agree upon these overtime rates shall be treated as a dispute under the Disputes clause of this contract.

(3) If the Schedule provides rates for overtime, the premium portion of those rates will be reimbursable only to the extent the overtime is approved by the Contracting Officer.

(ii) Materials.

(A) If the Contractor furnishes materials that meet the definition of a commercial item at 2.101, the price to be paid for such materials shall not exceed the Contractor's established catalog or market price, adjusted to reflect the--

( 1) Quantities being acquired; and (2) Any modifications necessary because of contract requirements.

Page 29 of 55

NRC-HQ-10-14-E-0005 (B) Except as provided for in paragraph (i)(1 )(ii)(A) and (0)(2) of this clause, the Government will reimburse the Contractor the actual cost of materials (less any rebates, refunds, or discounts received by the contractor that are identifiable to the contract) provided the Contractor--

(1) Has made payments for materials in accordance with the terms and conditions of the agreement or invoice; or (2) Makes these payments within 30 days of the submission of the Contractor's payment request to the Government and such payment is in accordance with the terms and conditions of the agreement or invoice.

(C) To the extent able, the Contractor shall--

(1) Obtain materials at the most advantageous prices available with due regard to securing prompt delivery of satisfactory materials; and (2) Give credit to the Government for cash and trade discounts, rebates, scrap, commissions, and other amounts that are identifiable to the contract.

(D) Other Costs. Unless listed below, other direct and iindirect costs will not be reimbursed.

(1) Other Direct Costs. The Government will reimburse the Contractor on the basis of actual cost for the following, provided such costs comply with the requirements in paragraph (i)(1 )(ii)(B) of this clause:

(2) Indirect Costs (Material Handling, Subcontract Administration, etc.). The Government will reimburse the Contractor for indirect costs on a pro-rata basis over the period of contract performance at the following fixed price:

(2) Total cost. It is estimated that the total cost to the Government for the performance of this contract shall not exceed the ceiling price set forth in the Schedule and the Contractor agrees to use its best efforts to perform the work specified in the Schedule and all obligations under this contract within such ceiling price. If at any time the Contractor has reason to believe that the hourly rate payments and material costs that will accrue in performing this contract in the next succeeding 30 days, if added to all other payments and costs previously accrued, will exceed 85 percent of the ceiling price in the Schedule, the Contractor shall notify the Contracting Officer giving a revised estimate of the total price to the Government for performing this contract with supporting reasons and documentation. If at any time during the performance of this contract, the Contractor has reason to believe that the total price to the Government for performing this contract will be substantially greater or less than the then stated ceiling price, the Contractor shall so notify the Contracting Officer, giving a revised estimate of the total price for performing this contract, with supporting reasons and documentation. If at any time during performance of this contract, the Government has reason to believe that the work to be required in performing this contract will be substantially greater or less than the stated ceiling price, the Contracting Officer will so advise the Contractor, giving the then revised estimate of the total amount of effort to be required under the contract.

(3) Ceiling price. The Government will not be obligated to pay the Contractor any amount in excess of the ceiling price in the Schedule, and the Contractor shall not be obligated to continue performance if to do so would exceed the ceiling price set forth in the Schedule, unless and until the Contracting Officer notifies the Contractor in writing that the ceiling price has been increased and specifies in the notice a revised ceiling that shall constitute the ceiling price for performance under this contract. When and to the extent that the ceiling price set forth in the Schedule has been increased, any hours expended and material costs incurred by the Contractor in excess of the ceiling price before the increase shall be allowable to the same extent as if the hours expended and material costs had been incurred after the increase in the ceiling price.

Page 30 of 55

NRC-HQ-10-14-E-0005 (4) Access to records. At any time before final payment under this contract, the Contracting Officer (or authorized representative) will have access to the following (access shall be limited to the listing below unless otherwise agreed to by the Contractor and the Contracting Officer):

(i) Records that verify that the employees whose time has been included in any invoice meet the qualifications for the labor categories specified in the contract; (ii) For labor hours (including any subcontractor hours reiimbursed at the hourly rate in the schedule),

when timecards are required as substantiation for payment--

(A) The original timecards (paper-based or electronic);

(B) The Contractor's timekeeping procedures; (C) Contractor records that show the distribution of labor between jobs or contracts; and (D) Employees whose time has been included in any invoice for the purpose of verifying that these employees have worked the hours shown on the invoices.

(iii) For material and subcontract costs that are reimbursed on the basis of actual cost--

(A) Any invoices or subcontract agreements substantiating material costs; and (B) Any documents supporting payment of those invoices.

(5) Overpayments/Underpayments. Each payment previously made shall be subject to reduction to the extent of amounts, on preceding invoices, that are found by the Contracting Officer not to have been properly payable and shall also be subject to reduction for overpayments or to increase for underpayments. The Contractor shall promptly pay any such reduction within 30 days unless the parties agree otherwise. The Government within 30 days will pay any such increases, unless the parties agree otherwise. The Contractor's payment will be made by check. If the Contractor becomes aware of a duplicate invoice payment or that the Government has otherwise overpaid on an invoice payment, the Contractor shall--

(i) Remit the overpayment amount to the payment office cited in the contract along with a description of the overpayment including the--

(A) Circumstances of the overpayment (e.g., duplicate payment, erroneous payment, liquidation errors, date(s) of overpayment);

(B) Affected contract number and delivery order number, if applicable; (C) Affected contract line item or subline item, if applicable; and (D) Contractor point of contact.

(ii) Provide a copy of the remittance and supporting documentation to the Contracting Officer.

(6)(i) All amounts that become payable by the Contractor to the Government under this contract shall bear simple interest from the date due until paid unless paid within 30 days of becoming due. The interest rate shall be the interest rate established by the Secretary of the Treasury, as provided in section 611 of the Contract Disputes Act of 1978 (Public Law 95-563), which is applicable to the period in which the amount Page 31 of 55

NRC-HQ-10-14-E-0005 becomes due, and then at the rate applicable for each six month period as established by the Secretary until the amount is paid.

(ii) The Government may issue a demand for payment to the Contractor upon finding a debt is due under the contract.

(iii) Final Decisions. The Contracting Officer will issue a final decision as required by 33.211 if--

(A) The Contracting Officer and the Contractor are unable to reach agreement on the existence or amount of a debt in a timely manner; (B) The Contractor fails to liquidate a debt previously demanded by the Contracting Officer within the timeline specified in the demand for payment unless the amounts were not repaid because the Contractor has requested an installment payment agreement; or (C) The Contractor requests a deferment of collection on a debt previously demanded by the Contracting Officer (see FAR 32.607-2).

(iv) If a demand for payment was previously issued for the debt, the demand for payment included in the final decision shall identify the same due date as the original demand for payment.

(v) Amounts shall be due at the earliest of the following dates:

(A) The date fixed under this contract.

(B) The date of the first written demand for payment, including any demand for payment resulting from a default termination.

(vi) The interest charge shall be computed for the actual number of calendar days involved beginning on the due date and ending on--

(A) The date on which the designated office receives payment from the Contractor; (B) The date of issuance of a Government check to the Contractor from which an amount otherwise payable has been withheld as a credit against the contract debt; or (C) The date on which an amount withheld and applied to the contract debt would otherwise have become payable to the Contractor.

(vii) The interest charge made under this clause may be reduced under the procedures prescribed in 32.608-2 of the Federal Acquisition Regulation in effect on the date of this contract.

(viii) Upon receipt and approval of the invoice designated by the Contractor as the "completion invoice" and supporting documentation, and upon compliance by the Contractor with all terms of this contract, any outstanding balances will be paid within 30 days unless the parties agree otherwise. The completion invoice, and supporting documentation, shall be submitted by the Contractor as promptly as practicable following completion of the work under this contract, but in no event later than 1 year (or such longer period as the Contracting Officer may approve in writing) from the date of completion.

(7) Release of claims. The Contractor, and each assignee under an assignment entered into under this contract and in effect at the time of final payment under this contract, shall execute and deliver, at the time of and as a condition precedent to final payment under this contract, a release discharging the Government, its Page 32 of 55

NRC-HQ-10-14-E-0005 officers, agents, and employees of and from all liabilities, obligations, and claims arising out of or under this contract, subject only to the following exceptions.

(i) Specified claims in stated amounts, or in estimated amounts if the amounts are not susceptible to exact statement by the Contractor.

(ii) Claims, together with reasonable incidental expenses, based upon the liabilities of the Contractor to third parties arising out of performing this contract, that are not known to the Contractor on the date of the execution of the release, and of which the Contractor gives notice in writing to the Contracting Officer not more than 6 years after the date of the release or the date of any notice to the Contractor that the Government is prepared to make final payment, whichever is earlier.

(iii) Claims for reimbursement of costs (other than expenses of the Contractor by reason of its indemnification of the Government against patent liability), including reasonable incidental expenses, incurred by the Contractor under the terms of this contract relating to patents.

(8) Prompt payment. The Government will make payment in accordance with the Prompt Payment Act (31 U.S.C. 3903) and prompt payment regulations at 5 CFR part 1315.

(9) Electronic Funds Transfer (EFT). If the Government malkes payment by EFT, see 52.212-5(b) for the appropriate EFT clause.

(10) Discount. In connection with any discount offered for early payment, time shall be computed from the date of the invoice. For the purpose of computing the discount earned, payment shall be considered to have been made on the date that appears on the payment check or the specified payment date if an electronic funds transfer payment is made.

U) Risk of loss. Unless the contract specifically provides otherwise, risk of loss or damage to the supplies provided under this contract shall remain with the Contractor until, and shall pass to the Government upon:

(1) Delivery of the supplies to a carrier, if transportation is f.o.b. origin; or (2) Delivery of the supplies to the Government at the destination specified in the contract, if transportation is f.o.b. destination.

(k) Taxes. The contract price includes all applicable Federal, State, and local taxes and duties.

(I) Termination for the Government's convenience. The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. In the event of such termination, the Contractor shall immediately stop all work hereunder and shall immediately cause any and all of its suppliers and subcontractors to cease work. Subject to the terms of this contract, the Contractor shall be paid an amount for direct labor hours (as defined in the Schedule of the contract) determined by multiplying the number of direct labor hours expended before the effective date of termination by the hourly rate(s) in the contract, less any hourly rate payments already made to the Contractor plus reasonable charges the Contractor can demonstrate to the satisfaction of the Government using its standard record keeping system that have resulted from the termination. The Contractor shall not be required to comply with the cost accounting standards or contract cost principles for this purpose. This paragraph does not give the Government any right to audit the Contractor's records. The Contractor shall not be paid for any work performed or costs incurred that reasonably could have been avoided.

(m) Termination for cause. The Government may terminate this contract, or any part hereof, for cause in the event of any default by the Contractor, or if the Contractor fails to comply with any contract terms and Page 33 of 55

NRC-HQ-10-14-E-0005 conditions, or fails to provide the Government, upon written request, with adequate assurances of future performance. Subject to the terms of this contract, the Contractor shall be paid an amount computed under paragraph (i) Payments of this clause, but the "hourly rate" for labor hours expended in furnishing work not delivered to or accepted by the Gov,ernment shall be reduced to exclude that portion of the rate attributable to profit. Unless otherwise specified in paragraph (a)(4) of this clause, the portion of the "hourly rate" attributable to profit shall be 10 percent. In the event of termination for cause, the Contractor shall be liable to the Government for any and all rights and remedies provided by law. If it is determined that the Government improperly terminated this contract for default, such termination shall be deemed a termination for convenience.

(n) Title. Unless specified elsewhere in this contract, title to items furnished under this contract shall pass to the Government upon acceptance, regardless of when or where the Government takes physical possession.

(o) Warranty. The Contractor warrants and implies that the items delivered hereunder are merchantable and fit for use for the particular purpose described in this contract.

(p) Limitation of liability. Except as otherwise provided by an express warranty, the Contractor will not be liable to the Government for consequential damages resulting from any defect or deficiencies in accepted items.

(q) Other compliances. The Contractor shall comply with all applicable Federal, State and local laws, executive orders, rules and regulations applicable to its performance under this contract.

(r) Compliance with laws unique to Government contracts. The Contractor agrees to comply with 31 U.S.C.

1352 relating to limitations on the use of appropriated funds to influence certain Federal contracts; 18 U.S.C.

431 relating to officials not to benefit; 40 U.S.C. 3701, et seq., Contract Work Hours and Safety Standards Act; 41 U.S.C. 51-58, Anti-Kickback Act of 1986; 41 U.S.C. 265 and 110 U.S.C. 2409 relating to wh1istleblower protections; 49 U.S.C. 40118, Fly American; and 41 U.S.C. 423 relating to procurement integrity.

(s) Order of precedence. Any inconsistencies in this solicitation or contract shall be resolved by giving precedence in the following order:

(1) The schedule of supplies/services.

(2) The Assignments, Disputes, Payments, Invoice, Other Compliances, and Compliance with Laws Unique to Government Contracts paragraphs of this clause.

(3) The clause at 52.212-5.

(4) Addenda to this solicitation or contract, including any license agreements for computer software.

(5) Solicitation provisions if this is a solicitation.

(6) Other paragraphs of this clause.

(7) The Standard Form 1449.

(8) Other documents, exhibits, and attachments (9) The specification.

(t) Central Contractor Registration (CCR).

Page 34 of 55

NRC-HQ-10-14-E-0005 (1) Unless exempted by an addendum to this contract, the Contractor is responsible during performance and through final payment of any contract for the accuracy and completeness of the data with1in the CCR database, and for any liability resulting from the Government's reliance on inaccurate or incomplete data. To remain registered in the CCR database after the initial registration, the Contractor is required to review and update on an annual basis from the date of initial registration or subsequent updates its information in the CCR database to ensure it is current, accurate and complete. Updating information in the CCR does not alter the terms and conditions of this contract and is not a substitute for a properly executed contractual document.

(2)(i) If a Contractor has legally changed its business name, "doing business as" name, or division name (whichever is shown on the contract), or has transferred the assets used in performing the contract, but has not completed the necessary requirements regarding novation and change-of-name agreements i1n FAR subpart 42.12, the Contractor shall provide the responsible Contracting Officer a minimum of one business day's written notification of its intention to (A) change the name in the CCR database; (B) comply with the requirements of subpart 42.12; and (C) agree in writing to the timeline and procedures specified by the responsible Contracting Officer. The Contractor must provide with the notification sufficient documentation to support the legally changed name.

(ii) If the Contractor fails to comply with the requirements of paragraph (t)(2)(i) of this clause, or fails to perform the agreement at paragraph (t)(2)(i)(C) of this clause, and, in the absence of a properly executed novation or change-of-name agreement, the CCR information that shows the Contractor to be other than the Contractor indicated in the contract will be considered to be incorrect information within the meaning of the "Suspension of Payment" paragraph of the electronic funds transfer (EFT) clause of this contract.

(3) The Contractor shall not change the name or address for EFT payments or manual payments, as appropriate, in the CCR record to reflect an assignee for the purpose of assignment of claims (see Subpart 32.8, Assignment of Claims). Assignees shall be separately registered in the CCR database. Information provided to the Contractor's CCR record that indicates payments, including those made by EFT, to an ultimate recipient other than that Contractor will be considered to be incorrect information within the meaning of the "Suspension of payment" paragraph of the EFT clause of this contract.

(4) Offerors and Contractors may obtain information on registration and annual confirmation requirements via CCR accessed through https://www.acquisition.gov or by calling 1-888-227-2423 or 269-961-5757.

C.21 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS--COMMERCIAL ITEMS (NOV 2012)

(a) The Contractor shall comply with the following Federal Acquisition Regulation (FAR) clauses, which are incorporated in this contract by reference, to implement provisions of law or Executive orders applicable to acquisitions of commercial items:

(1) 52.222-50, Combating Trafficking in Persons (FEB 2009) (22 U.S.C. 7104(g)).

Alternate I (AUG 2007) of 52.222-50 (22 U.S.C. 7104 (g)).

(2) 52.233-3, Protest After Award (Aug 1996) (31 U.S.C. 3553).

(3) 52.233-4, Applicable Law for Breach of Contract Claim (Oct 2004) (Pub. L. 108-77, 108-78)

(b) The Contractor shall comply with the FAR clauses in this paragraph (b) that the Contracting Officer has indicated as being incorporated in this contract by reference to implement provisions of law or Executive orders applicable to acquisitions of commercial items:

Page 35 of 55

NRC-HQ-10-14-E-0005

[X]

(1) 52.203-6, Restrictions on Subcontractor Sales to the Government (Sept 2006), with Alternate I (Oct 1995) (41 U.S.C. 253g and 10 U.S.C. 2402).

[X]

(2) 52.203-13, Contractor Code of Business Ethics and Conduct (APR 201 0)(Pub. L. 110-252, Title VI, Chapter 1 (41 U.S.C. 251 note)).

[] (3) 52.203-15, Whistleblower Protections under the American Recovery and Reinvestment Act of 2009 (JUN 2010) (Section 1553 of Pub. L. 111-5). (Applies to contracts funded by the American Recovery and Reinvestment Act of 2009.)

[X]

(4) 52.204-10, Reporting Executive Compensation and First-Tier Subcontract Awards (AUG 2012)

(Pub. L. 109-282) (31 U.S.C. 6101 note).

[] (5) 52.204-11, American Recovery and Reinvestment Act-Reporting Requirements (JUL 2010) (Pub.

L.111 -5).

[X]

(6) 52.209-6, Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment. (Dec 2010) (31 U.S.C. 6101 note).

[X]

(7) 52.209-9, Updates of Publicly Available Information Regarding Responsibility Matters (FEB 2012) (41 U.S.C. 2313).

[] (8) 52.209-10, Prohibition on Contracting with Inverted Domestic Corporations (MAY 2012) (section 738 of Division C of Pub. L. 112-7 4, section 7 40 of Division C of Pub. L. 111-117, section 7 43 of Division D of Pub. L. 111-8, and section 745 of Division D of Pub. L. 110-161).

[]

(9) 52.219-3, Notice of HUBZone Set-Aside or Sole-Source Award (NOV 2011) (15 U.S.C. 657a).

[] (10) 52.219-4, Notice of Price Evaluation Preference for HUBZone Small Business Concerns (JAN 2011) (if the offeror elects to waive the preference, it shall so indicate in its offer) (15 U.S.C. 657a).

[]

( 11 ) [Reserved]

[]

(12)(i) 52.219-6, Notice of Total Small Business Set-Aside (NOV 2011) (15 U.S.C. 644).

[] (ii) Alternate I (NOV 2011 ).

[] (iii) Alternate II (NOV 2011 ).

[] (13)(i) 52.219-7, Notice of Partial Small Business Set-Aside (June 2003) (15 U.S.C. 644).

[] (ii) Alternate I (Oct 1995) of 52.219-7.

[]

(iii) Alternate II (Mar 2004) of 52.219-7.

[X]

(14) 52.219-8, Utilization of Small Business Concerns (JAN 2011) (15 U.S.C. 637(d)(2) and (3)).

[] (15)(i) 52.219-9, Small Business Subcontracting Plan (JAN 2011) (15 U.S.C. 637(d)(4)).

[] (ii) Alternate I (Oct 2001) of 52.219-9.

Page 36 of 55

NRC-HQ-10-14-E-0005

[] (iii) Alternate II (Oct 2001) of 52.219-9.

[] (iv) Alternate Ill (JUL 2010) of 52.219-9.

[]

(16) 52.219-13, Notice of Set-Aside of Orders (NOV 2011) (15 U.S.C. 644(r)).

[X]

(17) 52.219-14, Limitations on Subcontracting (NOV 2011) (15 U.S.C. 637(a)(14)).

[] (18) 52.219-16, Liquidated Damages--Subcontracting Plan (Jan 1999) (15 U.S.C. 637(d)(4)(F)(i)).

[] (19)(i) 52.219-23, Notice of Price Evaluation Adjustment for Small Disadvantaged Business Concerns (OCT 2008) (10 U.S.C. 2323) (if the offeror elects to waive the adjustment, it shall so indicate in its offer.)

[] (ii) Alternate I (June 2003) of 52.219-23.

[] (20) 52.219-25, Small Disadvantaged Business Participation Program--Disadvantaged Status and Reporting (DEC 2010) (Pub. L. 103-355, section 7102, and 10 U.S.C. 2323).

[]

(21) 52.219-26, Small Disadvantaged Business Participation Program--lncentive Subcontracting (Oct 2000) (Pub. L. 103-355, section 7102, and 10 U.S.C. 2323).

[X]

(22) 52.219-27, Notice of Service-Disabled Veteran-Owned Small Business Set-Aside (NOV 2011)

(15 U.S.C. 657f).

[X]

(23) 52.219-28, Post Award Small Business Program Rerepresentation (APR 2012) (15 U.S.C 632(a)(2)).

[] (24) 52.219-29, Notice of Set-Aside for Economically Disadvantaged Women-Owned Small Business (EDWOSB) Concerns (APR 2012) (15 U.S.C. 637(m)).

[]

(25) 52.219-30, Notice of Set-Aside for Women-Owned Small Business (WOSB) Concerns Eligible Under the WOSB Program (APR 2012) (15 U.S.C. 637(m)).

[X]

(26) 52.222-3, Convict Labor (June 2003) (E.O. 11755).

[] (27) 52.222-19, Child Labor--Cooperation with Authorities and Remedies (MAR 2012) (E.O. 13126).

[X]

(28) 52.222-21, Prohibition of Segregated Facilities (Feb 1999).

[X]

(29) 52.222-26, Equal Opportunity (Mar 2007) (E.O. 11246).

[X]

(30) 52.222-35, Equal Opportunity for Veterans (SEP 2010) (38 U.S.C. 4212).

[X]

(31) 52.222-36, Affirmative Action for Workers with Disabilities (Oct 2010) (29 U.S.C. 793).

[X]

(32) 52.222-37, Employment Reports on Veterans (SEP 2010) (38 U.S.C. 4212).

[X]

(33) 52.222-40, Notification of Employee Rights Under the National Labor Relations Act (DEC 2010)

(E.O. 13496).

Page 37 of 55

NRC-HQ-10-14-E-0005

[X]

(34) 52.222-54, Employment Eligibility Verification (JUL 2012). (Executive Order 12989). (Not applicable to the acquisition of commercially available off-the-shelf items or certain other types of commercial items as prescribed in 22.1803.)

[]

(35)(i) 52.223-9, Estimate of Percentage of Recovered Material Content for EPA-Designated Items (May 2008) (42 U.S.C.6962(c)(3)(A)(ii)). (Not applicable to the acquisition of commercially available off-the-shelf items.)

[] (ii) Alternate I (MAY 2008) of 52.223-9 (42 U.S.C. 6962(i)(2)(C)). (Not applicable to the acquisition of commercially available off-the-shelf items.)

[] (36) 52.223-15, Energy Efficiency in Energy-Consuming Products (DEC 2007)(42 U.S.C. 8259b).

[] (37)(i) 52.223-16, IEEE 1680 Standard for the Environmental Assessment of Personal Computer Products (DEC 2007) (E.O. 13423).

[] (ii) Alternate I (DEC 2007) of 52.223-16.

[X]

(38) 52.223-18, Encouraging Contractor Policies to Ban Text Messaging While Driving (AUG 2011)

[]

(39) 52.225-1, Buy American Act--Supplies (FEB 2009) (41 U.S.C. 1 0a-1 0d).

[]

(40)(i) 52.225-3, Buy American Act--Free Trade Agreements-- Israeli Trade Act (NOV 2012) (41 U.S.C. chapter 83, 19 U.S.C. 3301 note, 19 U.S.C. 2112 note, 19 U.S.C. 3805 note, 19 U.S.C. 4001 note, Pub.

L. 103-182, 108-77, 108-78, 108-28'6, 108-302, 109-53, 109-169, 109-283, 110-138, 112-41, 112-42, and 112-43).

[]

(ii) Alternate I (MAR 2012) of 52.225-3.

[] (iii) Alternate II (MAR 2012) of 52.225-3.

[] (iv) Alternate Ill (NOV 2012) of 52.225-3.

[]

(41) 52.225-5, Trade Agreements (NOV 2012) (19 U.S.C. 2501, et seq., 19 U.S.C. 3301 note).

[X]

(42) 52.225-13, Restrictions on Certain Foreign Purchases (JUN 2008) (E.O.'s, proclamations, and statutes administered by the Office of Foreign Assets Control of the Department of the Treasury).

[] (43) 52.226-4, Notice of Disaster or Emergency Area Set-Aside (Nov 2007) (42 U.S.C. 5150).

[] (44) 52.226-5, Restrictions on Subcontracting Outside Disaster or Emergency Area (Nov 2007) (42 U.S.C. 5150).

[]

(45) 52.232-29, Terms for Financing of Purchases of Commercial Items (Feb 2002) (41 U.S.C. 255(f),

10 U.S.C. 2307(f)).

[]

(46) 52.232-30, Installment Payments for Commercial Items (Oct 1995) (41 U.S.C. 255(f), 10 U.S.C.

2307(f)).

[X]

(47) 52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration (Oct 2003)

(31 U.S.C. 3332).

Page 38 of 55

NRC-HQ-10-14-E-0005

[] (48) 52.232-34, Payment by Electronic Funds Transfer--Other than Central Contractor Registration (May 1999) (31 U.S.C. 3332).

[]

(49) 52.232-36, Payment by Third Party (FEB 2010) (311 U.S.C. 3332).

[] (50) 52.239-1, Privacy or Security Safeguards (Aug 1996) (5 U.S.C. 552a).

[] (51 )(i) 52.247-64, Preference for Privately Owned U.S.-Flag Commercial Vessels (Feb 2006) (46 U.S.C. Appx. 1241(b) and 10 U.S.C. 2631).

[] (ii) Alternate I (Apr 2003) of 52.247-64.

(c) The Contractor shall comply with the FAR clauses in this paragraph (c), applicable to commercial services, that the Contracting Officer has indicated as being incorporated in this contract by reference to implement provisions of law or Executive orders applicable to acquisitions of commercial items:

[] (1) 52.222-41, Service Contract Act of 1965 (Nov 2007) (41 U.S.C. 351, et seq.).

[]

(2) 52.222-42, Statement of Equivalent Rates for Federal Hires (May 1989) (29 U.S.C. 206 and 41 U.S.C. 351, et seq.).

Employee Class Monetary Wage-Fringe Benefits

[] (3) 52.222-43, Fair Labor Standards Act and Service Contract Act--Price Adjustment (Multiple Year and Option Contracts) (Sep 2009) (29 U.S.C. 206 and 41 U.S.C. 351, et seq.).

[]

(4) 52.222-44, Fair Labor Standards Act and Service Contract Act--Price Adjustment (Sep 2009) (29 U.S.C. 206 and 41 U.S.C. 351, et seq.).

[]

(5) 52.222-51, Exemption from Application of the Service Contract Act to Contracts for Maintenance, Calibration, or Repair of Certain Equipment--Requirements (Nov 2007) (41 U.S.C. 351, et seq.).

[]

(6) 52.222-53, Exemption from Application of the Service Contract Act to Contracts for Certain Services--Requirements (FEB 2009) (41 U.S.C. 351, et seq.).

[] (7) 52.226-6, Promoting Excess Food Donation to Nonprofit Organizations. (MAR 2009)(Pub. L. 110-247)

[] (8) 52.237-11, Accepting and Dispensing of $1 Coin (SEP 2008) (31 U.S.C. 5112(p)(1 )).

(d) Comptroller General Examination of Record. The Contractor shall comply with the provisions of this paragraph (d) if this contract was awarded using other than sealed bid, is in excess of the simplified acquisition threshold, and does not contain the clause at 52.215-2, Audit and Records--Negotiation.

(1) The Comptroller General of the United States, or an authorized representative of the Comptroller General, shall have access to and right to examine any of the Contractor's directly pertinent records involving transactions related to this contract.

(2) The Contractor shall make available at its offices at all reasonable times the records, materials, and other evidence for examination, audit, or reproduction, until 3 years after final payment under this contract or for any shorter period specified in FAR Subpart 4.7, Contractor Records Retention, of the other clauses of this Page 39 of 55

NRC-HQ-10-14-E-0005 contract. If this contract is completely or partially terminated, the records relating to the work terminated shall be made available for 3 years after any resulting final termination settlement. Records relating to appeals under the disputes clause or to litigation or the settlement of claims arising under or relating to this contract shall be made available until such appeals, litigation, or claims are finally resolved.

(3) As used in this clause, records include books, documents, accounting procedures and practices, and other data, regardless of type and regardless of form. This does not require the Contractor to create or maintain any record that the Contractor does not maintain in the ordinary course of business or pursuant to a provision of law.

(e)(1) Notwithstanding the requirements of the clauses in paragraphs (a), (b), (c), and (d) of this clause, the Contractor is not required to flow down any FAR clause, other than those in this paragraph (e)(1) in a subcontract for commercial items. Unless otherwise indicated below, the extent of the flow down shall be as required by the clause--

(i) 52.203-13, Contractor Code of Business Ethics and Conduct (APR 2010) (Pub. L. 110-252, Title VI, Chapter 1 (41 U.S.C. 251 note)).

(ii) 52.219-8, Utilization of Small Business Concerns (DEC 2010) (15 U.S.C. 637(d)(2) and (3)), in all subcontracts that offer further subcontracting opportunities. If the subcontract (except subcontracts to small business concerns) exceeds $650,000 ($1.5 million for construction of any public facility), the subcontractor must include 52.219-8 in lower tier subcontracts that offer subcontracting opportunities.

(iii) [Reserved]

(iv) 52.222-26, Equal Opportunity (Mar 2007) (E.O. 11246).

(v) 52.222-35, Equal Opportunity for Veterans (SEP 2010) (38 U.S.C. 4212).

(vi) 52.222-36, Affirmative Action for Workers with Disabilities (Oct 2010) (29 U.S.C. 793).

(vii) 52.222-40, Notification of Employee Rights Under the National Labor Relations Act (DEC 2010)

(E.O. 13496). Flow down required in accordance with paragraph (f) of FAR clause 52.222-40.

(viii) 52.222-41, Service Contract Act of 1965 (Nov 2007) (41 U.S.C. 351, et seq.).

(ix) 52.222-50, Combating Trafficking in Persons (FEB 2009) (22 U.S.C. 7104(9)).

Alternate I (AUG 2007) of 52.222-50 (22 U.S.C. 7104(9)).

(x) 52.222-51, Exemption from Application of the Service Contract Act to Contracts for Maintenance, Calibration, or Repair of Certain Equipment--Requirements "(Nov 2007)" (41 U.S.C. 351, et seq.).

(xi) 52.222-53, Exemption from Application of the Service Contract Act to Contracts for Certain Services-Requirements (FEB 2009)(41 U.S.C. 351, et seq.).

(xii) 52.222-54, Employee Eligibility Verification (JUL 2012)

(xiii) 52.226-6, Promoting Excess Food Donation to Nonprofit Organizations. (MAR 2009)(Pub. L. 110-247). Flow down required in accordance with paragraph (e) of FAR clause 52.226-6.

Page 40 of 55

NRC-HQ-10-14-E-0005 (xiv) 52.247-64, Preference for Privately Owned U.S.-Flag Commercial Vessels (Feb 2006) (46 U.S.C.

Appx. 1241(b) and 10 U.S.C. 2631). Flow down required in accordance with paragraph (d) of FAR clause 52.247-64.

(2) While not required, the contractor may include in its subcontracts for commercial items a minimal number of additional clauses necessary to satisfy its contractual obligations.

C.22 52.204-15 SERVICE CONTRACT REPORTING REQUIREMENTS FOR INDEFINITE-DELIVERY CONTRACTS (a) Definitions.

"First-tier subcontract" means a subcontract awarded directly by the Contractor for the purpose of acquiring supplies or services (including construction) for performance of a prime contract. It does not include the Contractor's supplier agreements with vendors, such as long-term arrangements for materials or supplies that benefit multiple contracts and/or the costs of which are normally applied to a Contractor's general and administrative expenses or indirect costs.

(b) The Contractor shall report, in accordance with paragraphs (c) and (d) of this clause, annually by October 31, for services performed during the preceding Government fiscal year (October 1-September 30) under this contract for orders that exceed the thresholds established in 4.1703(a)(2).

(c) The Contractor shall report the following information:

(1) Contract number and order number.

(2) The total dollar amount invoiced for services performed during the previous Government fiscal year under the order.

(3) The number of Contractor direct labor hours expended on the services performed during the previous Government fiscal year.

(4) Data reported by subcontractors under paragraph (f) of this clause.

(d) The information required in paragraph (c) of this clause shall be submitted via the internet at www.sam.gov.

(See SAM User Guide). If the Contractor fails to submit the report in a timely manner, the Contracting Officer will exercise appropriate contractual remedies. In addition, the Contracting Officer will make the Contractor's failure to comply with the reporting requirements a part of the Contractor's performance information under FAR Subpart 42.15.

(e) Agencies will review Contractor reported information for reasonableness and consistency with available contract information. In the event the agency believes that revisions to the Contractor reported information are warranted, the agency will notify the Contractor no later than November 15. By November 30, the Contractor shall revise the report, or document its rationale for the agency.

(f)(1) The Contractor shall require each first-tier subcontractor providing services under this contract, with subcontract(s) each valued at or above the thresholds set forth in 4.1703(a)(2), to provide the following detailed information to the Contractor in sufficient time to submit the report:

(i) Subcontract number (including subcontractor name and DUNS number), and Page 41 of 55

NRC-HQ-10-14-E-0005 (ii) The number of first-tier subcontractor direct-labor hours expended on the seNices performed during the previous Government fiscal year.

(2) The Contractor shall advise the subcontractor that the information will be made available to the public as required by section 743 of Division C of the Consolidated Appropriations Act, 2010.

C.23 52.216-18 ORDERING (OCT 1995)

(a) Any supplies and services to be furnished under this contract shall be ordered by issuance of delivery orders or task orders by the individuals or activities designated in the Schedule. Such orders may be issued from through.

(b) All delivery orders or task orders are subject to the terms and conditions of this contract. In the event of conflict between a delivery order or task order and this contract, the contract shall control.

(c) If mailed, a delivery order or task order is considered "issued" when the Government deposits the order in the mail. Orders may be issued orally, by facsimile, or by electronic commerce methods only if authorized in the Schedule.

C.24 52.216-19 ORDER LIMITATIONS (OCT 1995)

(a) Minimum order. When the Government requires supplies or services covered by this contract in an amount of less than, the Government is not obligated to purchase, nor is the Contractor obligated to furnish, those supplies or services under the contract.

(b) Maximum order.

The Contractor is not obligated to honor--

(1) Any order for a single item in excess of $11,000,000; (2) Any order for a combination of items in excess of 11,000,000.00; or (3) A series of orders from the same ordering office within 365 days that together call for quantities exceeding the limitation in paragraph (b)(1) or (2) of this section.

(c) If this is a requirements contr.act (i.e., includes the Requirements clause at subsection 52.216-21 of the Federal Acquisition Regulation (FAR)), the Government is not required to order a part of any one requirement from the Contractor if that requirement exceeds the maximum-order limitations in paragraph (b) of this section.

(d) Notwithstanding paragraphs (b) and (c) of this section, the Contractor shall honor any order exceeding the maximum order limitations in paragraph (b), unless that order (or orders) is returned to the ordering office within 7 days after issuance, with written notice stating the Contractor's intent not to ship the item (or items) called for and the reasons.

Upon r,eceiving this notice, the Government may acquire the supplies or seNices from another source.

C.25 52.216-22 INDEFINITE QUANTITY (OCT 1995)

(a) This is an indefinite-quantity contract for the supplies or services specified, and effective for the period stated, in the Schedule.

The quantities of supplies and seNices specified in the Schedule are estimates only and are not purchased by this contract.

(b) Delivery or performance shall be made only as authorized by orders issued in accordance with the Ordering clause.

The Contractor shall furnish to the Government, when and if ordered, the supplies or Page 42 of 55

NRC-HQ-10-14-E-0005 services specified in the Schedule up to and including the quantity designated in the Schedule as the "maximum." The Government shall order at least the quantity of supplies or services designated in the Schedule as the "minimum."

(c) Except for any limitations on quantities in the Order Limitations clause or in the Schedule, there is no limit on the number of orders that may be issued. The Government may issue orders requiring delivery to multiple destinations or performance at multiple locations.

(d) Any order issued during the effective period of this contract and not completed within that period shall be completed by the Contractor within the time specified in the order. The contract shall govern the Contractor's and Government's rights and obligations with respect to that order to the same extent as if the order were completed during the contract's effective period; provided, that the Contractor shall not be required to make any deliveries under this contract after 6 months from the expiration date of the contract.

C.26 52.217-8 OPTION TO EXTEND SERVICES (NOV 1999)

The Government may require continued performance of any services within the limits and at the rates specified in the contract.

These rates may be adjusted only as a result of revisions to prevailing labor rates provided by the Secretary of Labor. The option provision may be exercised more than once, but the total extension of performance hereunder shall not exceed 6 months. The Contracting Officer may exercise the option by written notice to the Contractor within 30 days of expiration of the then-current contract term.

C.27 52.217-9 OPTION TO EXTEND THE TERM OF THE CONTRACT (MAR 2000)

(a) The Government may extend the term of this contract by written notice to the Contractor within the contract period; provided that the Government gives the Contractor a preliminary written notice of its intent to extend at least 10 days before the contract expires. The preliminary notice does not commit the Government to an extension.

(b) If the Government exercises this option, the extended contract shall be considered to include this option clause.

(c) The total duration of this contract, including the exercise of any options under this clause, shall not exceed five (5) years.

C.28 52.219-27 NOTICE OF SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS SET-ASIDE (NOV 2011)

(a) Definition. "Service-disabled veteran-owned small business concern"-

(1) Means a small business concern-(i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans; and (ii) The management and daily business operations of which are controlled by one or more service-disabled veterans or, in the case of.a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran.

(2) "Service-disabled veteran" means a veteran, as defined in 38 U.S.C. 101 (2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).

Page 43 of 55

NRC-HQ-10-14-E-0005 (b) Applicability. This clause applies only to-(1) Contracts that have been set aside or reserved for serviice-disabled veteran-owned small business concerns; (2) Part or parts of a multiple-award contract that have been set aside for service-disabled veteran-owned small business concerns; and (3) Orders set aside for service-disabled veteran-owned small business concerns under multiple-award contracts as described in 8.405-5 and 16.505(b )(2)(i)(F).

( c) General.

(1) Offers are solicited only from service-disabled veteran-owned small business concerns. Offers received from concerns that are not service-disabled veteran-owned small business concerns shall not be considered.

(2) Any award resulting from this solicitation will be made to a service-disabled veteran-owned small business concern.

(d) Agreement. A service-disabled veteran-owned small business concern agrees that in the performance of the contract, in the case of a contract for-(1) Services (except construction), at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other service-disabled veteran-owned small business concerns; (2) Supplies (other than acquisition from a nonmanufacturer of the supplies), at least 50 percent of the cost of manufacturing, excluding the cost of materials, will be performed by the concern or other service-disabled veteran-owned small business concerns; (3) General construction, at least 15 percent of the cost of the contract performance incurred for personnel will be spent on the concern's employees or the employees of other service-disabled veteran-owned small business concerns; or (4) Construction by special trade contractors, at least 25 percent of the cost of the contract performance incurred for personnel will be spent on the concern's employees or the employees of other service-disabled veteran-owned small business concerns.

(e) A joint venture may be considered a service-disabled veteran owned small business concern if-(1) At least one member of the joint venture is a service-disabled veteran-owned small business concern, and makes the following representations: That it is a service-disabled veteran-owned small business concern, and that it is a small business concern under the North American Industry Classification Systems (NAICS) code assigned to the procurement; (2) Each other concern is small under the size standard corresponding to the NAICS code assigned to the procurement; and (3) The joint venture meets the requirements of paragraph 7 of the explanation of Affiliates in 19.101 of the Federal Acquisition Regulation.

Page 44 of 55

NRC-HQ-10-14-E-0005 (4) The joint venture meets the requirements of 13 CFR 125.15(b)

(f) Any service-disabled veteran-owned small business concern (nonmanufacturer) must meet the requirements in 19.102(f) of the Federal Acquisition Regulation to receive a benefit under this program.

C.29 52.219-14 LIMITATIONS ON SUBCONTRACTING (NOV 2011)

(a) This clause does not apply to the unrestricted portion of a partial set-aside.

(b) Applicability. This clause applies only to-(1) Contracts that have been set aside or reserved for smalll business concerns or 8(a) concerns; (2) Part or parts of a multiple-award contract that have been set aside for small business concerns or 8(a) concerns; and (3) Orders set aside for small business or 8(a) concerns under multiple-award contracts as described in 8.405-5 and 16.505(b )(2)(i)(F).

(c) By submission of an offer and execution of a contract, the Offeror/Contractor agrees that in performance of the contract in the case of a contract for--

(1) Services (except construction). At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern.

(2) Supplies (other than procurement from a nonmanufacturer of such supplies). The concern shall perform work for at least 50 percent of the cost of manufacturing the supplies, not including the cost of materials.

(3) General construction. The concern will perform at least 15 percent of the cost of the contract, not including the cost of materials, with its own employees.

(4) Construction by special trade contractors. The concern will perform at least 25 percent of the cost of the contract, not including the cost of materials, with its own employees.

C.30 52.228-5 INSURANCE -WORK ON A GOVERNMENT INSTALLATION (JAN 1997)

(a) The Contractor shall, at its own expense, provide and maintain during the entire performance of this contract, at least the kinds and minimum amounts of insurance required in the Schedule or elsewhere in the contract.

(b) Before commencing work under this contract, the Contractor shall notify the Contracting Officer in writing that the required insurance has been obtained. The policies evidencing required insurance shall contain an endorsement to the effect that any cancellation or any material change adversely affecting the Government's interest shall not be effective--

( 1) For such period as the laws of the State in which this contract is to be performed prescribe; or (2) Until 30 days after the insurer or the Contractor gives written notice to the Contracting Officer, whichever period is longer.

Page 45 of 55

NRC-HQ-10-14-E-0005 (c) The Contractor shall insert the substance of this clause, including this paragraph (c), in subcontracts under this contract that require work on a Government installation and shall require subcontractors to provide and maintain the insurance required in the Schedule or elsewhere in the contract. The Contractor shall maintain a copy of all subcontractors' proofs of required insurance, and shall make copies available to the Contracting Officer upon request.

C.31 52.232-99 PROVIDING ACCELERATED PAYMENT TO SMALL BUSINESS SUBCONTRACTORS (DEVIATION) (AUG 2012)

This clause implements the temporary policy provided by 0MB Policy Memorandum M-12-16, Providing Prompt Payment to Small Business Subcontractors, dated July 11, 2012.

(a) Upon receipt of accelerated payments from the Government, the contractor is required to make accelerated payments to small business subcontractors to the maximum extent practicable after receipt of a proper invoice and all proper documentation from the small business subcontractor.

(b) Include the substance of this clause, including this paragraph (b), in all subcontracts with small business concerns.

(c) The acceleration of payments under this clause does not provide any new rights under the Prompt Payment Act.

C.32 2052.209-70 CURRENT/FORMER AGENCY EMPLOYEE INVOLVEMENT (OCT 1999)

(a) The following representation is required by the NRC Acquisition Regulation 2009.105-?0(b).

It is not NRC policy to encourage offerors and contractors to propose current/former agency employees to perform work under NRC contracts and as set forth in the above cited provision, the use of such employees may, under certain conditions, adversely affect NRC's consideration of non-competitive proposals and task orders.

(b) There ( ) are ( ) are no currenUformer NRC employees (including special Government employees performing services as experts, advisors, consultants, or members of advisory committees) who have been or will be involved, directly or indirectly, in developing the offer, or in negotiating on behalf of the offeror, or in managing, administering, or performing any contract, consultant agreement, or subcontract resulting from this offer. For each individual so identified, the Technical and Management proposal must contain, as a separate attachment, the name of the individual, the individual's title while employed by the NRG, the date individual left NRC, and a brief description of the individual's role under this proposal.

C.33 2052.209-72 CONTRACTOR ORGANIZATIONAL CONFLICTS OF INTEREST (JAN 1993)

(a)

Purpose. The primary purpose of this clause is to aid in ensuring that the contractor:

(1) Is not placed in a conflicting role because of current or planned interests (financial, contractual, organizational, or otherwise) which relate to the work under this contract; and (2) Does not obtain an unfair competitive advantage over other parties by virtue of its performance of this contract.

(b) Scope. The restrictions described apply to performance or participation by the contractor, as defined in 48 CFR 2009.570-2 in the activities covered by this clause.

(c) Work for others.

Page 46 of 55

NRC-HQ-10-14-E-0005 (1) Notwithstanding any other provision of this contract, during the term of this contract, the contractor agrees to forego entering into consulting or other contractual arrangements with any firm or organization the result of which may give rise to a conflict of interest with respect to the work being performed under this contract. The contractor shall ensure that all employees under this contract abide by the provision of this clause.

If the contractor has reason to believe, with respect to itself or any employee, that any proposed consultant or other contractual arrangement with any firm or organization may involve a potential conflict of interest, the contractor shall obtain the written approval of the contracting officer before the execution of such contractual arrangement.

(2) The contractor may not represent, assist, or otherwise support an NRC licensee or applicant undergoing an NRC audit, inspection, or review where the activities that are the subject of the audit, inspection, or review are the same as or substantially similar to the services within the scope of this contract (or task order as appropriate) except where the NRC licensee or applicant requires the contractor's support to explain or defend the contractor's prior work for the utility or other entity which NRC questions.

(3) When the contractor performs work for the NRC under this contract at any NRC licensee or applicant site, the contractor shall neither solicit nor perform work in the same or similar technical area for that licensee or applicant organization for a period commencing with the award of the task order or beginning of work on the site (if not a task order contract) and ending one year after completion of all work under the associated task order, or last time at the site (if not a task order contract).

(4) When the contractor performs work for the NRC under this contract at any NRC licensee or applicant site, (i) The contractor may not solicit work at that site for that licensee or applicant during the period of performance of the task order or the contract, as appropriate.

(ii) The contractor may not perform work at that site for that licensee or applicant during the period of performance of the task order or the contract, as appropriate, and for one year thereafter.

(iii) Notwithstanding the foregoing, the contracting officer may authorize the contractor to solicit or perform this type of work (except work in the same or similar technical area) if the contracting officer determines that the situation will not pose a potential for technical bias or unfair competitive advantage.

(d)

Disclosure after award.

(1) The contractor warrants that to the best of its knowledge and belief, and except as otherwise set forth in this contract, that it does not have any organizational conflicts of interest as defined in 48 CFR 2009.570-2.

(2) The contractor agrees that if, after award, it discovers organizational conflicts of interest with respect to this contract, it shall make an immediate and full disclosure in writing to the contracting officer. This statement must include a description of the action which the contractor has taken or proposes to take to avoid or mitigate such conflicts.

The NRC may, however, terminate the contract if termination is in the best interest of the Government.

(3) It is recognized that the scope of work of a task-order-type contract necessarily encompasses a broad spectrum of activities. Cons,equently, if this is a task-order-type contract, the contractor agrees that it will disclose all proposed new work involving NRC licensees or applicants which comes within the scope of work of the underlying contract.

Further, if this contract involves work at a licensee or applicant site, the contractor agrees to exercise diligence to discover and disclose any new work at that licensee or applicant site.

This disclosure must be made before the submission of a bid or proposal to the utility or other regulated entity Page 47 of 55

NRC-HQ-10-14-E-0005 and must be received by the NRG at least 15 days before the proposed award date in any event, unless a written justification demonstrating urgency and due diligence to discover and disclose is provided by the contractor and approved by the contracting officer. The disclosure must include the statement of work, the dollar value of the proposed contract, and any other documents that are needed to fully describe the proposed work for the regulated utility or other regulated entity.

NRG may deny approval of the disclosed work only when the NRG has issued a task order which includes the technical area and, if site-specific, the site, or has plans to issue a task order which includes the technical area and, if site-specific, the site, or when the work violates paragraphs (c)(2), (c)(3) or (c)(4) of this section.

(e) Access to and use of information.

(1) If in the performance of this contract, the contractor obtains access to information, such as NRG plans, policies, reports, studies, financial plans, internal data protected by the Privacy Act of 1974 (5 U.S.C.

Section 552a (1988)), or the Freedom of Information Act (5 U.S.C. Section 552 (1986)), the contractor agrees not to:

(i) Use this information for any private purpose until the information has been released to the public; (ii) Compete for work for the Commission based on the information for a period of six months after either the completion of this contract or the release of the information to the public, whichever is first; (iii) Submit an unsolicited proposal to the Government based on the information until one year after the release of the information to the public; or (iv) Release the information without prior written approval by the contracting officer unless the information has previously been released to the public by the NRG.

(2) In addition, the contractor agrees that, to the extent it receives or is given access to proprietary data, data protected by the Privacy Act of 1974 (5 U.S.C. Section 552a (1988)), or the Freedom of Information Act (5 U.S.C. Section 552 (1986)), or other confidential or privileged technical, business, or financial information under this contract, the contractor shall treat the information in accordance with restrictions placed on use of the information.

(3) Subject to patent and security provisions of this contract, the contractor shall have the right to use technical data it produces under this contract for private purposes provided that all requirements of this contract have been met.

(f)

Subcontracts.

Except as provided in 48 CFR 2009.570-2, the contractor shall include this clause, including this paragraph, in subcontracts of any tier. The terms contract, contractor, and contracting officer, must be appropriately modified to preserve the Government's rights.

(g)

Remedies.

For breach of any of the above restrictions, or for intentional nondisclosure or misrepresentation of any relevant interest required to be disclosed concerning this contract or for such erroneous representations that necessarily imply bad faith, the Government may terminate the contract for default, disqualify the contractor from subsequent contractual efforts, and pursue other remedies permitted by law or this contract.

(h) Waiver. A request for waiver under this clause must be directed in writing to the contracting officer in accordance with the procedures outlined in 48 CFR 2009.570-9.

(i)

Follow-on effort. The contractor shall be ineligible to participate in NRG contracts, subcontracts, or proposals therefor (solicited or unsolicited), which stem directly from the contractor's performance of work Page 48 of 55

NRC-HQ-10-14-E-0005 under this contract.

Furthermore, unless so directed in writing by the contracting officer, the contractor may not perform any technical consulting or management support services work or evaluation activities under this contract on any of its products or services or the products or services of another firm if the contractor has been substantially involved in the development or marketing of the products or services.

(1) If the contractor, under this contract, prepares a complete or essentially complete statement of work or specifications, the contractor is not eligible to perform or participate in the initial contractual effort which is based on the statement of work or specifications. The contractor may not incorporate its products or services in the statement of work or specifications unless so directed in writing by the contracting officer, in which case the restrictions in this paragraph do not apply.

(2) Nothing in this paragraph precludes the contractor from offering or selling its standard commercial items to the Government.

C.34 WHISTLEBLOWER PROTECTION FOR NRC CONTRACTOR AND SUBCONTRACTOR EMPLOYEES (AUG 2011)

(a) The U.S. Nuclear Regulatory Commission (NRC) contractor and its subcontractor are subject to the Whistleblower Employee Protection public law provisions as codiified at 42 U.S.C. 5851. NRC contractor(s) and subcontractor(s) shall comply with the requirements of this Whistleblower Employee Protection law, and the implementing regulations of the NRC and the Department of Labor (DOL).

See, for example, DOL Procedures on Handling Complaints at 29 C.F.R. Part 24 concerning the employer obligations, prohibited acts, DOL procedures and the requirement for prominent posting of notice of Employee Rights at Appendix A to Part 24 entitled: "Your Rights Under the Energy Reorganization Act".

(b) Under this Whistleblower Employee Protection law, as implemented by regulations, NRG contractor and subcontractor employees are protected from discharge, reprisal, threats, intimidation, coercion, blacklisting or other employment discrimination practices with respect to compensation, terms, conditions or privileges of their employment because the contractor or subcontractor employee(s) has provided notice to the employer, refused to engage in unlawful practices, assisted in proceedings or testified on activities concerning alleged violations of the Atomic Energy Act of 1954 (as amended) and the Energy Reorganization Act of 197 4 (as amended).

(c) The contractor shall insert this or the substance of this clause in any subcontracts involving work performed under this contract.

C.35 USE OF AUTOMATED CLEARING HOUSE (ACH) ELECTRONIC PAYMENT/REMITTANCE ADDRESS (AUG 2011)

The Debt Collection Improvement Act of 1996 requires that all Federal payments except IRS tax refunds be made by Electronic Funds Transfer. It is the policy of the Nuclear Regulatory Commission to pay government vendors by the Automated Clearing House (ACH) electronic funds transfer payment system.

Item 15C of the Standard Form 33 may be disregarded.

C.36 GREEN PURCHASING (JUN 2011)

COST PROPOSAL-COVER PAGE The offeror's cost proposal shall include the following information to identify the major category that best represents the environmental products and services included in the proposal, as applicable.

Page 49 of 55

NRC-HQ-10-14-E-0005 In the offeror's cost proposal cover page, select the most prominent green category from the list provided below and provide a corresponding total dollar amount for the category.

"The preponderance of green purchasing included in this proposal includes:

Category: _______

(Select the most prominent green category, only}

Dollar Amount: $ ____ "

(Offerers may include $0 for IDIQs, Requirements contracts and other contract vehicles where the actual work will be implemented through the award of task or delivery orders.)

Select Only One of the Following Categories:

A. Recycled Content Products B. Energy-Efficient Products:

Energy Star, FEMP-Designated, and Low Standby Power Devices C. Biobased Products D. Environmentally Preferable Products and Services (excluding EPEAT)

E. Electronic Product Environmental Assessment Tool (EPEAT) Products F. Water-Efficient Products G. SNAP/Non-Ozone Depleting Substances H. Alternative Fuel Vehicles and Alternative Fuels I. Not Applicable A listing of designated EPA products can be found at:

http://www.epa.gov/epawaste/conserve/tools/cpg/i ndex. htm C.37 52.209-7 INFORMATION REGARDING RESPONSIBILITY MATTERS (FEB 2012)

(a) Definitions. As used in this provision--

"Administrative proceeding" means a non-judicial process that is adjudicatory in nature in order to make a determination of fault or liability (e.g., Securities and Exchange Commission Administrative Proceedings, Civilian Board of Contract Appeals Proceedings, and Armed Services Board of Contract Appeals Proceedings).

This includes administrative proceedings at the Federal and State level but only in connection with performance of a Federal contract or grant. It does not include agency actions such as contract audits, site visits, corrective plans, or inspection of deliverables.

"Federal contracts and grants with total value greater than $10,000,000" means--

(1) The total value of all current, active contracts and grants, including all priced options; and (2) The total value of all current, active orders including all priced options under indefinite-delivery, indefinite-quantity, 8(a), or requirements contracts (including task and delivery and multiple-award Schedules).

Page 50 of 55

NRC-HQ-10-14-E-0005 "Principal" means an officer, director, owner, partner, or a person having primary management or supervisory responsibilities within a business entity (e.g., general manager; plant manager; head of a division or business segment; and similar positions).

(b) The offeror [] has (] does not have current active Federal contracts and grants with total value greater than $10,000,000.

(c) If the offeror checked "has" in paragraph (b) of this provision, the offeror represents, by submission of this offer, that the information it has entered in the Federal Awardee Performance and Integrity Information System (FAPIIS) is current, accurate, and complete as of the date of submission of this offer with regard to the following information:

(1) Whether the offeror, and/or any of its principals, has or has not, within the last five years, in connection with the award to or performance by the offeror of a Federal contract or grant, been the subject of a proceeding, at the Federal or State level that resulted in any of the following dispositions:

(i) In a criminal proceeding, a conviction.

(ii) In a civil proceeding, a finding of fault and liability that results in the payment of a monetary fine, penalty, reimbursement, restitution, or damages of $5,000 or more.

(iii) In an administrative proceeding, a finding of fault and liability that results in--

(A) The payment of a monetary fine or penalty of $5,000 or more; or (B) The payment of a reimbursement, restitution, or damages in excess of $100,000.

(iv) In a criminal, civil, or administrative proceeding, a disposition of the matter by consent or compromise with an acknowledgment of fault by the Contractor if the proceeding could have led to any of the outcomes specified in paragraphs (c)(1 )(i), (c)(1 )(ii), or (c)(1 )(iii) of this provision.

(2) If the offeror has been involved in the last five years in any of the occurrences listed in (c)(1) of this provision, whether the offeror has provided the requested information with regard to each occurrence.

(d) The offeror shall post the information in paragraphs (c)(1 )(i) through (c)(1 )(iv) of this provision in FAPIIS as required through maintaining an active registration in the Central Contractor Registration database via https://www.acquisition.gov (see 52.204-7).

Page 51 of 55

-'US.NRC IJUl.. 5c:maa N'.Ju, Lpl1.,.rC..-1llua

~

,_,,,.,.,,.,P.,,... _,

NRC-HQ-10-14-E-0005 SECTION D - Attachments INVOICE FORMAT FOR FIXED-PRICE Version Control Date: May 2, 2013 ATTACHMENT 1 BILLING INSTRUCTIONS FOR FIXED-PRICE TYPE CONTRACTS (MAY 2013)

General: During performance and through final payment of this contract, the contractor is responsible for the accuracy and completeness of data within the System for Award Management (SAM) database and for any liability resulting from the Government's reliance on inaccurate or incomplete SAM data.

The contractor shall prepare invoices/vouchers for payment of deliverables identified in the contract, in the manner described herein. FAILURE TO SUBMIT INVOICESNOUCHERS IN ACCORDANCE WITH THESE INSTRUCTIONS MAY RESULT IN REJECTION OF THE INVOICE/VOUCHER AS IMPROPER.

Standard Forms:

Payment requests for completed work, in accordance with the contract, shall be submitted on the payee's letterhead, invoice/voucher, or on the Government's Standard Form 1034, "Public Voucher for Purchases and Services Other than Personal," and Standard Form 1035, "Public Voucher for Purchases Other than Personal--Continuation Sheet."

Electronic Invoice/Voucher Submissions:

The preferred method of submitting invoices/vouchers is electronically to the U.S. Nuclear Regulatory Commission, via email to:

NRCPayments@nrc.gov.

Hard-Copy Invoice/Voucher Submissions: If you submit a hard-copy of the invoice/voucher, a signed original and supporting documentation shall be submitted to the following address:

NRC Payments U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mailstop O3-E17A Rockville, MD 20852-2738 Purchase of Capital Property:

($50,000 or more with life of one year or longer)

Contractors must report to the Contracting Officer, electronically, any capital property acquired with contract funds having an initial cost of $50,000 or more, in accordance with procedures set forth in NRC Management Directive (MD) 13.1, IV, C - "Reporting Requirements" (revised 2/16/201 1).

Agency Payment Office:

Payment will continue to be made by the office designated in the contract in Block 12 of Standard Form 26, Block 25 of Standard Form 33, or Block 18a of Standard Form 1449, whichever is applicable.

Frequency:

The contractor shall submit invoices/vouchers for payment once each month, unless otherwise authorized by the Contracting Officer.

Page 52 of 55

NRC-HQ-10-14-E-0005 Format:

lnvoicesNouchers shall be submitted in the format depicted on the attached sample form entitled "lnvoiceNoucher for Purchases and Services Other Than Personal". Alternate formats are permissible only if they address all requirements of the Billing Instructions. The instructions for preparation and itemization of the invoice/voucher are included with the sample form.

Task Order Contracts: The contractor must submit a separate invoice/voucher for each individual task order with pricing information. This includes items discussed in paragraphs (a) through (p) of the attached instructions. In addition, the invoice/voucher must specify the contract number, and the NRC-assigned task/delivery order number.

Final vouchers/invoices shall be marked "FINAL INVOICE" or "FINAL VOUCHER".

Currency: lnvoicesNouchers must be expressed in U.S. Dollars.

Supersession: These instructions supersede previous Billing Instructions for Fixed-Price Type Contracts (July 2011 ).

Page 53 of 55

NRC-HQ-10-14-E-0005 INVOICENOUCHER FOR PURCHASES AND SERVICES OTHER THAN PERSONAL (SAMPLE FORMAT - COVER SHEET)

1. Official Agency Billing Office NRC Payments U.S. Nuclear Regulatory Commission One White Flint North 11 555 Rockville Pike Mailstop O3-E17A Rockville, MD 20852-2738
2.

lnvoiceNoucher Information

a.

Payee's DUNS Number or DUNS+4. The Payee shall include the Payee's Data Universal Number (DUNS) or DUNS+4 number that identifies the Payee's name and address. The DUNS+4 number is the DUNS number plus a 4-character suffix that may be assigned at the discretion of the Payee to identify alternative Electronic Funds Transfer (EFT) accounts for the same parent concern.

b.

Taxpayer Identification Number.. The Payee shall include the Payee's taxpayer identification number (TIN) used by the Internal Revenue Service (IRS) in the administration of tax laws. (See IRS Web site:

http://www.irs.gov/Businesses/Small-Businesses-&-Self-Employed/Employer-lD-Numbers-(EINs)).

c.

Payee's Name and Address.

Show the name of the Payee as it appears in the contract and its correct address.

Where the Payee is authorized to assign the proceeds of this contract in accordance with the clause at FAR 52.232-23, the Payee shall require as a condition of any such assignment, that the assignee shall register separately in the System for Award Management (SAM) database at http://sam.gov and shall be paid by EFT in accordance with the terms of this contract.

See Federal Acquisition Regulation (FAR) 52.232-33(9)

Payment by Electronic Funds Transfer - Central Contractor Registration (October 2003).

d.

Contract Number.

Insert the NRC contract number (including Enterprise-wide Contract (EWC)), GSA Federal Supply Schedule (FSS), Governmentwide Agency Contract (GWAC) number, or Multiple Agency Contract (MAC) number, as applicable.

e. Task Order Number. Insert the task/delivery order number {If Applicable). Do not include more than one task order per invoice or the invoice may be rejected as improper.
f. lnvoiceNoucher. The appropriate sequential number of the invoice/voucher, beginning with 001 should be designated.

Contractors may also include an individual internal accounting number, if desired, in addition to the 3-digit sequential number.

g.

Date of lnvoiceNoucher.

Insert the date the invoice/voucher is prepared.

h. Billing Period. Insert the beginning and ending dates (day, month, year) of the period during which deliverables were completed and for which payment is requested.
i.

Description of Deliverables.

Provide a brief description of supplies or services, quantity, unit price, and total price.

j. Work Completed.

Provide a general summary description of the services performed or products submitted for the invoice period and specify the section or Contract Line Item Number (CLIN) or SubCLIN in the contract Page 54 of 55

NRC-HQ-10-14-E-0005 pertaining to the specified contract deliverable(s).

k.

Shipping. Insert weight and zone of shipment, if shipped by parcel post.

I.

Charges for freight or express shipments. Attach prepaid bill if shipped by freight or express.

m.

Instructions.

Include instructions to consignee to notify the Contracting Officer of receipt of shipment.

n.

For Indefinite Delivery contracts, the final invoice/voucher shall be marked FINAL INVOICE" or "FINAL VOUCHER".

o.

Total Amount Billed.

Insert columns for total amounts for the current and cumulative periods.

p.

Adjustments. Insert columns for any adjustments, including outstanding suspensions for deficient or defective products or nonconforming services, for the current and cumulative periods.

q.

Grand Totals.

Page 55 of 55

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE MOOOl 06/23 / 201 7
6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VI SION MAI L STOP 3WFN-05-C64MP WASHI NGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION 564 LOISDALE COURT SUITE PRINGFI ELD Q

6 s

s PRINGFIELD VA 22150-1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

11. CONTRACT 10 CODE I PAGE OF PAGES 1

I 1

4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /II app//cabla)

ZEROREQ-OCI0 0086

7. ADMINISTERED BY (//other than Item 6)

CODE I (x) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED /SEE ITEM 11) 10A. MODIFICATION OF CONTRACT/ORDER NO.

X NRC-HQ-10 E- 0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth In Item 14. The hour and date specified for receipt of Offers

"* Is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior 10 the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference lo the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required}
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE X

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF; u. uTHEK /::;pec,ry type or modmcatton and authontY)

FAR 52. 217-9 Opt ion to Extend t he Term of the Contract E. IMPORTANT:

Contractor 7 is not, x is required to sign this document and return -----~l~_ copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including sol/citallon/contract subject matter where feasible.)

The purpose of t his modifi cation is to : 1. ) Exercise Option Year 2, thereby extendi ng t he pe riod of pe rformance through 6/ 22/2017; and 2. ) Update the Contract ing Officer Representative from Eli zabeth Crawford to Kristen Benney, and del egate Karen Danoff as the alternate COR.

All other terms and conditions remain t he same.

LIST OF CHANGES:

Reason for Modifi cation Exercise an Opti on Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME ANO TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR (Signature of person authon'zed ro sign)

NSN 7540-01-152-8070 Previous edition ~nusable 15C. DATE SIGNED 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

DOMONIQUE MALONE H

16C. DATE SIGNED 06/20/2016 STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE M0002 See Block 16C
6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VISION MAIL STOP 3WFN-05-C64MP WASHI NGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION TTN JOHN DULAN 564 LOISDALE COURT SUITE PRINGFIELD Q

A 6

s s PRINGFI ELD VA 22150- 1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

11. CONTRACT 10 CODE I PAGE OF PAGES 1

I 2

4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /II app//cabla)

ZEROREQ-OCI0-17-0040

7. ADMINISTERED BY (//other than Item 6)

CODE I (x) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED /SEE ITEM 11) 10A. MODIFICATION OF CONTRACT/ORDER NO.

X NRC-HQ-10 E- 0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth In Item 14. The hour and date specified for receipt of Offers

"* Is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior 10 the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference lo the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

See Schedule

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE X

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF; u. uTHEK /::;pec,ry type or modmcatton and authontY)

E. IMPORTANT:

Contractor x] is not, is required to sign this document and return ______

copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including sol/citallon/contract subject matter where feasible.)

The purpose of t his administrative modification is to reflect (1) a change to the Buyer designation from Domonique Malone to Fati ma Shuler, (2) a change to t he Contracting Offi cer Representative (COR) designation from Kristen Benney to Karen Danoff, and (3) a change to delegate Krist en Benney as the alternate COR.

Ms. Shuler ' s contact i nformation is :

E-mail : Fatima. Shuler@nrc. gov Phone : 301-415-704 4 Ms. Danoff ' s contact i nformation is :

E-mai l : Karen. Danoff@nrc.gov Continued...

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME ANO TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR (Signature of person authon'zed ro sign)

NSN 7540-01-152-8070 Previous edition ~nusable 15C. DATE SIGNED 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

DOMINIQUE MALONE 16B. UNITED STATES OF AMERICA D~C-~

16C. DATE SIGNED 03/23/2017

/S/gnaturo of Contracting O/flcer)

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

REFERENCE NO. OF DOCUMENT BEING CONTINUED CONTINUATION SHEET NRC-HQ-lO-l4-E-0005/M0002 NAME OF OFFEROR OR CONTRACTOR QUALX CORPORATI ON ITEM NO.

(A)

Phone : 301-415-5072 SUPPLIES/SERVICES

( B)

Ms. Benney ' s contact information E-mail : Kristen. Benney@nrc.gov Phone : 301-415-6355 is :

All other i tems and conditions remained unchanged.

NSN 7540-01-152-8067 QUANTITY UNIT UNIT PRICE (C )

(D)

(E)

OF AMOUNT (F)

OPTIONAL FORM 336 (4-86)

Sponsored by GSA FAR (48 CFR) 53.110 2

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE M0003 See Block 16C
6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VISION MAIL STOP TWFN-8E06M WASHINGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION TTN JOHN DULAN 564 LOISDALE COURT SUITE PRINGFIELD Q

A 6

s s PRINGFIELD VA 22150- 1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

11. CONTRACT 10 CODE I PAGE OF PAGES 1

I 1

4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /II app//cabla)

ZEROREQ-OCI 0-17-0090

7. ADMINISTERED BY (//other than Item 6)

CODE I (x) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED /SEE ITEM 11) 10A. MODIFICATION OF CONTRACT/ORDER NO.

X NRC-HQ-10 E- 0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth In Item 14. The hour and date specified for receipt of Offers

"* Is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior 10 the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference lo the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/OROER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE X

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF; u. uTHEK /::;pec,ry type or modmcatton and authontY)

FAR 52. 217-9 Option to Extend t he Term of the Contract E. IMPORTANT:

Contractor x] is not, is required to sign this document and return _______

copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including sol/citallon/contract subject matter where feasible.)

The purpose of t his modification is to : 1. ) Exercise Option Year 3, thereby extendi ng t he pe riod of pe rformance through 6/22/2018.

All other t erms and conditions remain the same.

LIST OF CHANGES :

Reason for Modificat ion Exercise an Option Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME ANO TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR (Signature of person authon'zed ro sign)

NSN 7540-01-152-8070 Previous edition ~nusable 15C. DATE SIGNED 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

DOMINIQUE MALONE 16B. UNITED STATES OF AMERICA D~C.~

16C. DATE SIGNED 06/16/2017

/S/gnaturo of Contracting O/flcer)

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

11. CONTRACT 10 CODE I PAGE OF PAGES 1

I 1

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /II app//cabla)

M0004 See Block 16C ZEROREQ-OCI 0-18-0065

6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VISION MAIL STOP TWFN-8E06M WASHINGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION TTN JOHN DULAN 564 LOISDALE COURT SUITE PRINGFIELD Q

A 6

s s PRINGFIELD VA 22150- 1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

7. ADMINISTERED BY (//other than Item 6)

CODE I (x) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED /SEE ITEM 11) 10A. MODIFICATION OF CONTRACT/ORDER NO.

X NRC-HQ-10 E- 0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth In Item 14. The hour and date specified for receipt of Offers

"* Is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior 10 the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference lo the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/OROER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE X

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF; u. uTHEK /::;pec,ry type or modmcatton and authontY)

FAR 52. 217-9 Option to Extend t he Term of the Contract E. IMPORTANT:

Contractor x] is not, is required to sign this document and return ______

copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including sol/citallon/contract subject matter where feasible.)

LIST OF CHANGES :

Reason for Modifi cation : Exercise an Opt i on Period Of Performance End Date changed from 22-JUN-18 to 22-JUN-19 Total Amount for this Modification : $0.00 New Total Amount for t his Version : $11, 000, 000. 00 New Total Amount for t his Award : $11, 000, 000.00 The purpose of t his modification is to exercise Option Year 4, t hereby ext ending the period of performance t hrough 6/22/2019 Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME ANO TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR (Signature of person authon'zed ro sign)

NSN 7540-01-152-8070 Previous edition ~nusable 15C. DATE SIGNED 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

DOMONIQUE MALONE 16B. UNITED STATES OF AMERICA D~C.~

16C. DATE SIGNED 04/04/2018

/S/gnaturo of Contracting O/flcer)

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

11. CONTRACT 10 CODE I PAGE OF PAGES 1

I 2

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /II app//cabla)

MOOOS See Block 16C ZEROREQ-OCI 0-19-0061

6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VISION MAIL STOP TWFN-8E06M WASHINGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION TTN JOHN DULAN 564 LOISDALE COURT SUITE PRINGFIELD Q

A 6

s s PRINGFIELD VA 22150- 1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

7. ADMINISTERED BY (//other than Item 6)

CODE I (x) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED /SEE ITEM 11) 10A. MODIFICATION OF CONTRACT/ORDER NO.

X NRC-HQ-10 E- 0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth In Item 14. The hour and date specified for receipt of Offers

"* Is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior 10 the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers.

FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR ANO DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made, by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to th,e opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

N/A

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

8. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

X C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF;

u. uTHEK /::;pec,ry type 01 modmcatton and authontY)

E. IMPORTANT:

Contractor x] is not is required to sign this document and return ______

copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including sol/citallon/contract subject matter where feasible.)

The purpose of t his administrative modification is to delegate Krist en Benne y as the Alte rnate COR. Kristen may be reached at :

Email : Kristen. Benney@nrc. gov Phone : 301-415-6355 Total Obligated Amount : $0. 00 (unchanged)

Current Ceiling (Base and Exercised Options )

$11, 000, 000. 00 (unchanged)

Total Ceiling (Base and all Options) :

Continued...

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME ANO TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED (Signature of person authon'zed ro sign)

Previous edition unusable 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

DOMONIQUE MALONE 16B. UNITED STATES OF AMERICA D~C-~

/S/gna1uro of Contracting Officer) 16C. DATE SIGNED 03/14/2019 STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

REFERENCE NO. OF DOCUMENT BEING CONTINUED CONTINUATION SHEET NRC-HQ-lO-l4-E-0005/M0005 NAME OF OFFEROR OR CONTRACTOR QUALX CORPORATION ITEM NO.

(A )

$11, 000, 000. 00 NSN 7540-01-152-8067 SUPPLIES/SERVICES

( B)

(unchanged)

QUANTITY (C )

UNIT UNIT PRICE (D)

(E)

OF AMOUNT (F)

OPTIONAL FORM 336 (4-86)

Sponsored by GSA FAR (48 CFR) 53.110 2

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

11. CONTRACT ID CODE I PAGE OF PAGES 1

I 2

2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ. NO.
15. PROJECT NO. /If applicable)

M0006 See Block 16C ZEROREQ-AMD 0119

6. ISSUED BY CODE NRCHQ US NRC -

HQ ACQUISITION MANAGEMENT DI VI SION MAI L STOP TWFN-8E06M WASHI NGTON DC 20555-0001

8. NAME AND ADDRESS OF CONTRACTOR (No..

UALX CORPORATION TTN JOHN DULAN 564 LOI SDALE COURT SUITE PRINGFIELD Q

A 6

s s PRINGFI ELD VA 22150- 1830 CODE 831798702 street, county, State and ZIP Code) 305 FACILITY CODE

7. ADMINISTERED BY (lfother/han Item 6)

CODE I 12 9A. AMENDMENT OF SOLICITATION NO.

9B, DATED /SEE ITEM 11)

X 10A. MODIFICATION OF CONTRACT/ORDER NO.

NRC-HQ-10-14-E-0005 10B. DATED /SEE ITEM 13) 06/20/2014

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation Is amended as set forth in Item 14. The hour and date specified for receipt of Offers

~

is extended.

is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing llems 8 and 15, and returning

____ copies of the amendment; (b) By acknowledging receipt or this amendment on each copy or the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers.

FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment. and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

N/A

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14, CHECK ONE X

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B, THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification end authorlJy/

E. IMPORTANT:

Contractor x] is not is required to sign this document and return _______

_ copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, Including sol/citation/contract subject matter where feasible,)

The purpose of t his modifi cation is to i ncorporate FAR 52. 237-3 Continuity of Services i nt o t his cont ract. As r es ult of thi s a ction, FAR 52. 237-3 is he r eby incorpor ated under section C. 38 :

C. 38 52. 237-3 CONTINUI TY OF SERVICES (JAN 1991)

(a ) The Cont r actor recognizes t hat the services under thi s cont r act a re vital to t he Government and must be continued wi thout interruption and t hat, upon contract expi r ation, a successor, either t he Government or anot her contractor, may cont inue them. The Contractor agrees t o (1) furnis h phase-in t r ai ning and (2) exer ci se its best eff orts and cooperation to eff ect an Continued...

Except as provid eel herein, all terms and conditions of the document referenced in Item 9 A or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED (Signature of person authorized ro sign)

Previous edition unusable 16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

JERRY PURCELL 16B. UNITED STATES OF AMERICA

--~)

-(._ /-<-

(S/gnoturo of Contracting Officer) 16C. DATE SIGNED 03/26/ 2020 STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

REFERENCE NO. OF DOCUMENT BEING CONTINUED CONTINUATION SHEET NRC-HQ-10-14-E-0005/M0006 NAME OF OFFEROR OR CONTRACTOR QUALX CORPORATI ON ITEM NO.

(A)

SUPPLIES/SERVICES

( B) orderly and efficient transition to a successor.

(b) The Contractor shall, upon the Contracting Officer' s written noti ce,

phase-out services for up contract expires and (2) a (1) f urnish phase-in,

to 90 days after this negotiate in good faith plan with a successor to determine the nature and extent of phase-in, phase-out services required.

The pl an shall specify a training program and a date for transferring responsibilities for each division of work described i n t he plan, and s hall be subject to the Contracting Offi cer' s approval. The Contractor shall provide sufficient experienced personnel during the phase-in, phase-out period to ensure that t he services called for by t his contract are maintained at t he required level of proficiency.

(c) The Contractor shall allow as many personnel as practicable to remain on the job to help the successor maintain the continui t y and consistency of the services required by this contract.

The Contractor also s hall disclose necessary personnel records and allow the successor to conduct on-site interviews with these employees.

If selected employees are agreeable to the change, the Contractor s hall release them at a mutually agreeable dat e and negotiate transfer of their earned fringe benefits to the successor.

(d) The Contractor shall be reimbursed for al l reasonable phase-in, phase-out costs (i.e., costs incurred wi thin the agreed period after contract expiration that result from phase-in, phase-out operations ) and a fee (profit ) not to exceed a prorata port ion of the fee (profit) under t his contract.

(End of c l ause)

NSN 7540-01-152-8067 QUANTITY UNIT (C )

(D)

UNIT PRICE (E )

OF AMOUNT (F)

OPTIONAL FORM 336 (4-86)

Sponsored by GSA FAR /48 CFR\\ 53.110 2

Qualx FOIA #:

NRC-2021-000240 Contract#:

NRC-HQ-10-14-E-0005 Task Order#: NRC-HQ-10-14-T-0001 Period of Performance: 07/01/2014 - 05/31/2020 Billing Period Invoice Invoice

$735,001.44 Billing Period Invoice Invoice

$202,324.34 2019 Date Amount 2020 Date Amount January 53 02/05/2019

$37,200.76 January 65 02/07/2020

$21,150.45 February 54 03/04/2019

$35,089.72 February 66 03/05/2020

$18,802.40 March 55 04/04/2019

$40,602.61 March 67 04/10/2020

$21,568.88 April 56 05/02/2019

$36,498.81 April 68 05/12/2020

$21,771.20 May 57 06/03/2019

$29,448.17 May 698 06/26/2020

$17,869.24 June 58 07/02/2019

$27,736.56 Total 2020

$101,162.17 July 59 08/02/2019

$29,687.18 August 60 09/05/2019

$29,427.15 September 61 10/04/2019

$19,083.88 October 62 11/13/2019

$28,591.28 November 63 12/04/2019

$26,814.40 December 64 01/03/2020

$27,320.20 Total 2019

$367,500.72