ML21278A380

From kanterella
Jump to navigation Jump to search
Nevada Regulations 2015-3 App B
ML21278A380
Person / Time
Issue date: 09/29/2021
From:
Office of Nuclear Material Safety and Safeguards
To:
Beardsley M
Shared Package
ML21278A364 List:
References
Download: ML21278A380 (4)


Text

ATTACHMENT B RATS ID 2015-3 THE STATE BOARD OF HEALTH LCB File No. R021-18 Effective June 2, 2019 EXPLANATION - Matter in italics is new; matter in brackets [omitted material] is material to be omitted.

459.1997 1. The provisions of 10 C.F.R. §§ 71.0(c), 71.1(a), 71.3, 71.4, 71.14(a), 71.15, 71.17, 71.21, 71.22, 71.23, 71.47, 71.83 to 71.89, inclusive, 71.91(c), 71.91(d), 71.97, 71.101(a),

71.101(b), 71.101(c), 71.101(g), 71.103(a), 71.103(b), 71.105, 71.106, 71.127 to 71.137, inclusive, and Appendix A to Part 71 are hereby adopted by reference, subject to the following:

(a) The exclusion of the following definitions from 10 C.F.R. § 71.4:

(1) Close reflection by water; (2) Licensed material; (3) Optimum interspersed hydrogenous moderation; (4) Spent nuclear fuel or spent fuel; and (5) State.

(b) The substitution of the following rule references:

(1) NAC 459.737 for § 34.31(b) of this chapter as found in 10 C.F.R. § 71.101(g); (2)

Subsection 1 of NAC 459.339 for 10 C.F.R § 20.1502; (3) NAC 459.3062 for 10 C.F.R. Part 35; (4) Subsection 6 of NAC 459.3585 for 10 C.F.R. § 20.1906(e);

(5) NAC 459.181 for 10 C.F.R. § 71.5; Sec. 24.

NAC 459.1997 is hereby amended to read as follows:

--30--

f f d

d d

l (6) 10 C.F.R. §§ 71.101(a), 71.101(b), 71.101(c)(1), 71.101(g), 71.105 and 71.127 to 71.137, inclusive, for subpart H of this part or subpart H, except in 10 C.F.R. §§ 71.17(b),

71.21(b), 71.22(b) and 71.23(b);

(7) 10 C.F.R. §§ 71.0(c), 71.1(a), 71.3, 71.4, 71.17(c)(2), 71.21(d)(2), 71.83 to 71.89, inclusive, 71.97, 71.101(a), 71.101(b), 71.101(c)(1), 71.101(g), 71.105 and 71.127 to 71.137, inclusive, for subparts A, G and H of this part; (8) 10 C.F.R. § 71.47 for subparts E and F of this part; and (9) 10 C.F.R. §§ 71.101(a), 71.101(b), 71.101(c)(1), 71.101(g), 71.105 and 71.127 to 71.137, inclusive, for §§ 71.101 through 71.137.

(c) The substitution of the following terms:

(1) Division for:

(I) Commission in 10 C.F.R. §§ 71.0(c), 71.17(a), 71.21(a), 71.22(a), 71.23(a) and 71.101(c)(1);

(II) Director, Division of [Nuclear] Security [,] Policy, Office of Nuclear Security and Incident Response in 10 C.F.R. §§ 71.97(c)(1) and 71.97(f)(1);

(III) Director, Division of [Intergovernmental Liaison and Rulemaking,] Materials Safety, Security, State, and Tribal Programs, Office of [Federal and State Materials and Environmental Management Programs,] Nuclear Material Safety and Safeguards, U.S.

Nuclear Regulatory Commission, Washington, D.C. 20555-0001 in 10 C.F.R. § 71.97(c)(3)(iii); and (IV) NRC in 10 C.F.R. § 71.101(f);

(2) The Nuclear Regulatory Commission or an agreement state for Commission in 10 C.F.R. § 71.

--31--

f f d

d d

l (3) The Governor of Nevada for:

(I) The governor of a State in 10 C.F.R. § 71.97(a);

(II) Each appropriate governor in 10 C.F.R. § 71.97(c)(1);

(III) The governor in 10 C.F.R. § 71.97(c)(3);

(IV) The governor of the State in 10 C.F.R. § 71.97(e);

(V) The governor of each State in 10 C.F.R. § 71.97(f)(1); and (VI) A governor in 10 C.F.R. § 71.97(e);

(4) State of Nevada for State in 10 C.F.R. §§ 71.97(a), 71.97(b)(2) and 71.97(d)(4);

(5) The Governor of Nevadas for:

(I) The governors in 10 C.F.R. §§ 71.97(a), 71.97(c)(3), 71.97(e) and 71.97(f)(1);

(II) Governors in 10 C.F.R. §§ 71.97(c)(1) and 71.97(e); and (III) Governors in 10 C.F.R. § 71.97(c)(3)(iii);

(6) Specific or general for NRC in 10 C.F.R. § 71.0(c);

(7) The Division for ATTN: Document Control Desk, Director, Division of Spent Fuel

[Storage and Transportation,] Management, Office of Nuclear Material Safety and Safeguards in 10 C.F.R. § 71.101(c)(1);

(8) Each for Using an appropriate method listed in § 71.1(a), each in 10 C.F.R. § 71.101(c)(1);

(9) The material must be contained in a Type A package meeting the requirements of 49 C.F.R. § 173.417(a) for The fissile material need not be contained in a package which meets the standards of subparts E and F of this part; however, the material must be contained in a Type

--32--

f f d

d d

l A package. The Type A package must also meet the DOT requirements of 49 C.F.R.

173.417(a) as found in 10 C.F.R. §§ 71.22(a) and 71.23(a);

(10) Licensee for licensee, certificate holder, and applicant for a CoC; and (11) Licensee is for licensee, certificate holder, and applicant for a CoC are.

2. A copy of the publication that contains 10 C.F.R. Part 71 may be obtained by mail from the Superintendent of Documents, United States Government [Printing] Publishing Office, P.O.

Box 979050, St. Louis, Missouri 63197-9000, or by toll-free telephone at (866) 512-1800, at the price of $64, or free of charge at the Internet address

[1]

https://www.ecfr.gov/.