ML21274A018

From kanterella
Jump to navigation Jump to search
Nbsr Report on February 3, 2021 Fuel Failure Event, Root Causes, Corrective Actions, and Restart Readiness
Date released: 10/04/2021 Download: ML21274A018


Nbsr Report on February 3, 2021 Fuel Failure Event, Root Causes, Corrective Actions, and Restart Readiness
ML21274A027
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 10/01/2021
From: Dimeo R
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML21274A027 (2)
Corrective Action Plan Corrective Actions Required Post-startup
ML21274A026
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/30/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A026 (2)
Corrective Action Plan Corrective Actions Required Prior to Reactor Startup
ML21274A025
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/30/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A025 (2)
Memorandum on Recovery Items
ML21274A024
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/21/2021
From: Newton T
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A024 (1)
Latch Improvement Safety Analysis
ML21274A023
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/21/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A023 (2)
Root Cause Response, Revision 1
ML21274A022
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/20/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A022 (10)
Final Report Sec Subcommittee Report: Review of the NCNR Event Response and Technical Working Root Cause Analysis and Corrective Action Plan
ML21274A021
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 08/12/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A021 (28)
NCNR Twg Report Addendum to Root Cause Investigation of February 2021 Fuel Failure
ML21274A020
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 06/03/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A020 (1)
NCNR Twg Report Root Cause Investigation of February 2021 Fuel Failure, Revision 2
ML21274A019
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 09/13/2021
From:
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To:
Office of Nuclear Reactor Regulation
References
Download: ML21274A019 (28)