INTENTIONALLY LEFT BLANK LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT FIGURE 9.1-1

LGS UFSAR Figure 9.1-2 thru 9.1-4 Deleted

UPPER FRAME LOWER FRAME CARRIAGE LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT FUEL PREPARATION MACHINE SHOWN INSTALLED IN FACSIMILE FUEL POOL FIGURE 9.1-5

INTENTIONALLY LEFT BLANK LIMERICK GENERA TING ST A TION UNITS 1 AND 2 UPDATED FlNAL SAFETY ANALYSIS REPORT NEW FUEL INSPECTION STAND FIGURE g.1-6 Rev. 2 July/g2

CABLE_/

/SHAFT HOUSING Of TENT LEAF SPRINGS LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT CHANNEL BOLT WRENCH FIGURE 9.1-7

GUIDES (TYPICAL OF 2)

LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT CHANNEL HANDLING TOOL FIGURE 9.1-8

T OEMINERALIZEO WATER INLET FROM REFUELING FLOOR 5 gpm AT 30 psi MINIMUM MALE CONNECTOR FOR 0.75 i.d. HOSE 33.00: 0.12 115 ft Al"Pf'IOX 3 WIRE CAP NEMA STANDARD L5 15 CAT NO GL-4726 VENDOR GESCO MOTOR STARTER SWITCH 1100 ~0.05

,_"'4t--~-10.13 MAX DIA PART NO 1

2 3

VAC 115 110 220 DRAIN TO FUEL l"OOL 0.75 o.d. TUBING Hz 60 50 50 PANEL WT CONTAINER 50 lb 11511">

8.25 :+ 0.17 FUEL POOL RAILING i.------15.81+0.12------~*

LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT FUEL POOL SIPPER FIGURE 9.1-9

-~j~0.66 0.02 TVP 1.31 10.~0v;a----~

l+IA(o.12 TOTI TYP LOWER MTG SURFACE 0.50 THK REQD 0.60

  • 0.02 DIA HOLE IN 1.IFTING EYE 0

APPROX WT 8.7 lb LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT FUEL INSPECTION FIXTURE FIGURE 9.1-10

1-FRAME 3-SCREW l 6-LOCKWASHER 8-F LA TWAS HER 9-NUT (TYPICAL OF 8)

~---=~/

2~GAUGING PLATE 4-SHIM 5-GAUGING BLOCK BLOCK MOUNTING HWD 7-BOLT 6-LOCKWASHER

~~----------------

8-FLATWASHER (TYPICAL OF 4)

LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT CHANNEL GAUGING FIXTURE FIGURE 9.1-11

STUD RECEPTACLE (7/16 -

14 UNC)

VIEW PORT SET SCREW GRAPPLE HOOKS TORSION BAR HOUSING LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT GENERAL-PURPOSE GRAPPLE FIGURE 9.1-12

INTENTIONALLY LEFT BLANK LIMERICK GENERA TING STA HON UNITS 1 AND 2 UPDATED FINAL SAFETY ANALYSIS REPORT REFUELING OUT AGE FLOW DIAGRAM FIGURE 9.1-13 Rev. 2 July/92

INTENTIONALLY LEFT BLANK LIMERICK GENERATING STATION

~ITS 1 ANO 2 UPDATED FlNAL. SAFETY ANALYSlS REPORT SIMPLIFIED SECTION OF NEW FUEL HANDLING FACILITIES (SECTION X-X, FIGURE 9.1-17)

FIGURE <ll-14 Rev. 1 J uly/'H Z1\\MECH\\ 0901014.Sl

INTENTIONALLY LEFT BLANK LIMERICK GEtERATING STATION UNITS 1 ANO 2 UPDATED FlNAL SAFETY ANALYSlS REPORT SIMPLIFIED SECTION OF REFUELING FACILITIES

<SECTION Y-Y, FIGURE q.1-17)

FIGURE 9.1-15 Rev. 1 July/91 Z1\\MECH\\ 0901015.Sl

INTENTIONALLY LEFT BLANK LIMERICK GENERA TING STATION UNITS 1 AND 2 lPOATEO FINAL SAFETY ANALYSIS REPORT SIMPLIFIED SECTION OF FUEL SHIPPING F ACIL l TIES

<SECTION Z-Z, FIGURE 9.1-17>

FIGURE 9.1-16 Z1\\MECH\\ 0'301016.Sl

LGS UFSAR Figure 9.1-17 Deleted

LGS UFSAR Figures 9.5-1 thru 9.5-12 Deleted