HISTOREConsolidatedInterimStorageFacility RequestsforAdditionalInformationRound2 HoltecLetter5025069
Page1of5 CHAPTER2RAIs RAI233S:Justifywhythematerialproperties,asgiveninTable5.3ofReportNo.HI2188143,Revision 1,HISTOREBearingCapacityandSettlementCalculations,areappropriatetorepresentthematerials attheproposedsite.
Clarifywhythevalueassignedtosomegeotechnicalparametersisappropriateforthesite.Forexample:
1)Table5.3oftherevisedreportgivesafrictionanglefortheResidualSoilatthesiteas54o.Thisis anextremelyhighvalueevenformostofthehard,igneousrockandcertainlyforasoil.
AppendixCofReportNo.HI2188143,Revision1,BearingCapacityandSettlement Calculation,hasusedaformulatocalculatethefrictionanglefromEPRI(Kuhlhawayand Main,1990):
=5427.6034[0.0014x(1)60]
AsafunctionofthecorrectedStandardPenetrationTestblowcount(N1)60.AppendixCshows that(N1)valuesvaryfrom58to173;however,thecalculatedvalueofremainsconstant54o irrespectiveof(N1)60values.ProvidetheappropriatefrictionangleoftheResidualSoil.
Additionally,providethecorrectsourceofthisequationifitisnotinthereferencedEPRI document
2)Intherevisedreport,thepreconsolidationstressoftheChinleFormationistakenasthe valueestimatedinsampleSW2,obtainedatdepthof101ftbelowthegroundsurface.Provide therationaleforusingthemeasuredconsolidationpropertiesfromsampleSW2butnotfrom SW1.TheestimatedoverconsolidationratiofromonlySW2sampleseemsveryhigh.Provide therationalefortheestimatedvaluesofthepreconsolidationstressandtheoverconsolidation ratio.
3)ProvidearationaleforwhythemeasuredconsolidationpropertiesinChinlemudstoneata depthof101ftfromthesurface(sampleSW2)wouldbeappropriateforconsolidation settlementinChinleclay(leanclayorCL)formationnearthesurface.
4)PageA9oftherevisedreportstatesthattheChinleFormationmudstonesectionisconsidered bedrock.Also,thefulldepthoftheChinleisconsideredinthecalculation
HoltecResponse:
Thegeotechnicalparametersandtheirassignedvaluesusedtorepresenttheproposedsiteareclarified below.
1)Uponreview,itappearsthattheequationinthecalculationwascitedincorrectly.This equationisnotusedinouranalysesdevelopedforthisRAIresponse.Basedontheboringlog descriptionsoftheResidualsoil,theprevioususeof54degreesforfrictionangleandahigh valueofcohesionareincorrect.
InthelatestrevisiontoHoltecReportHI2188143,thesoilfrictionanglefortheResidualsoilis determinedusingFigure4-12ofKulhawayandMayne(1990).Thecalculationalsonow
HISTOREConsolidatedInterimStorageFacility RequestsforAdditionalInformationRound2 HoltecLetter5025069
Page2of5 includesasmallvalueofdrainedcohesiontoaccountfortheplasticitydescribedwithinthe material.
TheResidualSoilclassifiesasSandyClayorClayeySand.Becauseofthelowwatercontentand unsaturatedinsituconditionoftheResidualSoil,itisappropriatetousedrainedstrength parametersforthismaterial.Africtionangleof44degreescorrespondstotheupperlimitof thecorrelationpresentedinFigure4-12ofKulhawyandMayne,anditisareasonablefriction angleforthismaterial.Duetotheclaycontentofthissoil,asmalldrainedcohesionintercept of200psfisalsoreasonable.Thus,adrainedfrictionangleof44degreesandadrained cohesionof200psfareusedforthebearingcapacityanalysisoftheISFSIandtheCTF.
Thespecifieddensityofthecontrolledlowstrengthmaterial(CLSM)usedtofillbeneaththe ISFSIpadhasalsobeenreducedto120pcftoalignwiththeestablishedvalueforthegeneric HISTORMUMAXlicense,ratherthanusingaconservativevalueof150pcfpertheprevious HI-STOREsubmittal.Thismodificationresultsinareductioninstaticbearingpressureforthe ISFSIPadto3.34ksf.
UsingtheserevisedstrengthparametersfortheResidualSoil,Holteccomputedthefollowing allowablebearingcapacitiesandappliedbearingpressuresontheHI-STOREISFSIpadandthe CTFfoundations.Inallcasesallowablebearingcapacityisgreaterthantheappliedbearing pressure,indicatingbearingcapacityfactorsofsafetyareadequate.
Structure AllowableStaticBearingCapacity(ksf)
BearingPressure(ksf)
Static Seismic Static Seismic ISFSIPad 5.38 8.07 3.34 4.34 CTF 104.02 156.03 4.33 7.05
- 2) Uponfurtherreview,HoltecagreeswiththeNRCstaffthatitispreferrabletouse consolidationpropertiesfromSW1forsettlementanalysessincetheshapeoftheplot indicatesasoilbehaviormoreinlinewithclassicalsoilmechanicstheorycomparedtoSW2.
TheshapeofthecurveoftestSW2appearstoshowamoresevereimpactfromstressrelief duetosamplinginthefield.Inaddition,SW1hasahigherinitialwatercontentthanSW2 (13.7%inSW1ascomparedwith8.0%inSW2).Ingeotechnicalliterature,compressibility generallyrelatestowatercontent,withahigherwatercontentcorrelatingwithhigher compressibility.Therefore,thecompressibilitypropertiesassociatedwithSW1shouldbe conservativerelativetoSW2.
Tocalculatethemaximumpastpressure(orpreconsolidationstress)fortheChinleFormation, HoltechasperformedaCasagrandeconstructionontheconsolidationplotoftestSW1 followingrecognizedsoilmechanicsliterature.Withthismethod,apreconsolidationstressof approximately3.1tonspersquarefoot(tsf)isobtained.TestSW1wasperformedatadepthof
HISTOREConsolidatedInterimStorageFacility RequestsforAdditionalInformationRound2 HoltecLetter5025069
Page3of5 approximately74.3feet(El.3455.8).Atthatdepth,ourcalculationspredictanexistinginsitu verticalstressofapproximately4.3tsf,whichwouldindicateanunder-consolidatedsoil.Given thegeologyandtheinformationfromthefieldandthelabtests,includingthehighSPT N-valuesandrelativelylowwatercontents,Holtecbelievesthemeasuredpreconsolidation stressislowerthantheactualinsitupreconsolidationstress,likelyduetostressrelieffrom samplinginthefield.Therefore,therevisedcalculationsconservativelyassumethattheChinle Formationisnormallyconsolidated(OCR=1.0),i.e.,themaximumpastpressureatanydepth isequaltotheexistinginsituverticaleffectivestress.
Thespecifieddensityofthecontrolledlowstrengthmaterial(CLSM)usedtofillbeneaththe ISFSIpadhasalsobeenreducedto120pcftoalignwiththeestablishedvalueforthegeneric HISTORMUMAXlicense,ratherthanusingaconservativevalueof150pcfpertheprevious HI-STOREsubmittal.Thismodificationresultsinareductioninstaticbearingpressureforthe ISFSIPadto3.34ksf.
Tomakeaproperanddirectcomparisonwiththe0.2inchsettlementlimitpresentedinTable 2.3.2oftheHISTORMUMAXFSAR,thelongtermsettlementfortheHISTOREISFSIis computedforthesamereferencepadsizeevaluatedinthegenericUMAXlicense,namelya 5x5arrayofVVMs.
AnOCRof1hasbeenusedfortherevisedsettlementcalculationsfortheISFSIpadandforthe CTFfoundation.ThecalculatedlongtermsettlementoftheISFSIpadandCTFfoundationare asfollows:
Structure TotalConsolidationSettlement inChinleFormation Centerofpad(in)
ISFSIPad 0.15 CTF 0.11
3&4) AsnotedintheresponsetoRAI2-32-S,part2above,HoltecagreeswiththeNRCstaffthatitis preferabletouseconsolidationpropertiesfromSW1ratherthanSW2.
BasedonGEIsSiteCharacterizationReport,theChinleFormationisasingleunitwiththetop oftheformationbetweenElevations3499and3502andthebottomoftheformationbetween Elevations3322and332(topofSantaRosaFormation).Thereisnogeologicdistinction betweenChinleFormationclayandChinleFormationmudstone.Intheboringlogs,the distinctionbetweenclayandmudstoneisduetothesamplingmethod,i.e.,mudstoneis calledoutwhenthematerialbecomeshardenoughtocore.
Inaddition,Holteccomparedlaboratoryindextestresultsfromtheshallowersamplesinthe ChinleFormation,whereStandardPenetrationTest(SPT)samplingwasperformed,withthe watercontentfromtestSW1atapproximately74.3feetbelowgrade.Intheliterature,
HISTOREConsolidatedInterimStorageFacility RequestsforAdditionalInformationRound2 HoltecLetter5025069
Page4of5 compressibilityrelatestowatercontentandAtterberglimits.SincetherearenoAtterberg limitstestsperformedontheChinlerockcores,Holtecanalyzedwatercontentresults.
ThewatercontentreportedatshallowerdepthsintheChinlearelowerthanthatreportedfor SW1,whichwouldindicatealowercompressibility.Basedonthenaturalwatercontentvalues reportedinTables3fromGEIsSiteCharacterizationReportfortheChinleFormation,ata depthrangebetween30and56.4feetbelowgrade,Holtecobtainedanaveragewatercontent of11.7%.TheinitialwatercontentfromSW1is13.7%asreportedinTable4ofGEIsSite CharacterizationReport.Thelowerwatercontentwouldcorrelatewithalowercompressibility, andthereforeusingtheSW1consolidationparametersthroughtheentireChinleFormationis conservative.
RAI242S:Justifywhyatwolayersystem,asusedinReportNo.HI-2188143,Revision1,HISTORE BearingCapacityandSettlementCalculations,wouldbeappropriateforestimatingthebearingcapacity andsettlementofthestoragepads.
PageA9ofReportNo.HI-2188143,Revision1,HISTOREBearingCapacityandSettlement Calculations,statesthattheChinleFormationmudstonesectionisconsideredbedrock.Also,thefull depthoftheChinleisconsideredinthecalculationabove(175ft),thisisconservativeasthemudstone willnotsettleasmuchastheclay.TheresponsetoRAI242statesthat[i]nthelatestrevisionof ReportNo.HI2188143,thetopCLsoillayerisconservativelyassumedathroughouttheentire175ft depthoftheChinleFormation.Thesestatementssuggestthatthesettlementcharacteristicsofthe ChinleFormationclaysectionaredifferentthantheChinleFormationmudrock.Providetherationalefor selectingatwolayersystemforestimatingthesettlementunderthestoragepadsandtheCanister TransferFacilityinsteadofamultilayersystem.
Thisinformationisnecessarytodeterminecompliancewith10CFR72.24,72.103,and72.122.
HoltecResponse:
BasedonGEIsSiteCharacterizationReport,theChinleFormationisasingleunitwiththetopofthe formationbetweenElevations3499and3502andthebottomoftheformationbetweenElevations 3322and3321(topofSantaRosaFormation).ThereisnogeologicdistinctionbetweenChinle FormationclayandChinleFormationmudstone.Intheboringlogs,thedistinctionbetweenclay andmudstoneisduetothesamplingmethod,i.e.,mudstoneiscalledoutwhenthematerialbecomes hardenoughtocore.Accordingtotheboringlogs,theChinleFormationmaterialbecomeshardenough tocorebetweenElevations3434.5and3499.6,withanaverageof3469.
InresponsetothequestionsraisedinthisRAI,Holtecperformedadditionalsettlementcalculationsfor boththeISFSIPadandtheCTF.GiventhethicknessandpropertiesoftheChinleFormation(see responsetoRAI2-32-2),thelongtermsettlementundertheISFSIPadandCTFarecalculatedusinga multi-layersysteminaccordancewiththemethodologydescribedinHoltecPositionPaperDS-338.To calculatethetotallongtermconsolidationsettlement,theChinleFormationisdividedintofourlayers betweenElevations3500and3469,andtwolayersbetweenElevations3469and3321.5.
HISTOREConsolidatedInterimStorageFacility RequestsforAdditionalInformationRound2 HoltecLetter5025069
Page5of5 OnlythesettlementintheChinleFormationisconsideredbecausetheResidualSoilisagranular materialwhichhasalowmoisturecontent,isabovethewatertable,andisnotsaturated.Therefore, thesettlementintheResidualSoilwilloccurimmediatelyuponloadingandwillnotcontributetolong termsettlement.Thereboundduetoexcavationandreconsolidationbacktotheinitialexistingstressin theChinleFormationisalsoassumedtooccurrapidly.Therefore,theconsolidationsettlementis calculatedfromtheinitialstress(alsoequaltothemaximumpastpressure)tothefinalstress.The revisedcalculationsinHoltecReportHI2188143conservativelyassumenormallyconsolidated conditionsandusethecompressionindexreportedintestSW1tocalculatetheconsolidation settlement(seediscussioninresponsetoRAI2-32-S).Theloadreductionmethodologyof30-degree angleasdescribedinHoltecsDryStoragePositionPaperDS-338,whichisincorporatedbyreferencein theHISTORMUMAXFSAR,isalsoused.
Thespecifieddensityofthecontrolledlowstrengthmaterial(CLSM)usedtofillbeneaththeISFSIpad hasalsobeenreducedto120pcftoalignwiththeestablishedvalueforthegenericHISTORMUMAX license,ratherthanusingaconservativevalueof150pcfperthepreviousHI-STOREsubmittal.This modificationresultsinareductioninstaticbearingpressurefortheISFSIPadto3.34ksf.
Tomakeaproperanddirectcomparisonwiththe0.2inchsettlementlimitpresentedinTable2.3.2of theHISTORMUMAXFSAR,thelongtermsettlementfortheHISTOREISFSIiscomputedforthesame referencepadsizeevaluatedinthegenericUMAXlicense,namelya5x5arrayofVVMs.
Thefinalresultsaresummarizedinthetablebelow.
Structure TotalLongTermConsolidation SettlementinChinleFormation Centerofpad(in)
ISFSIPad 0.15 CTF 0.11
References AASHTOLRFDBridgeDesignSpecifications,9thEdition,2020.
GEIConsultants,Inc.(GEI).HI-STORECISFPhase1SiteCharacterizationReport,Rev1,LeaCounty,New Mexico,February2018.
J.E.Bowles,FoundationsAnalysisandDesign,5thEdition,McGrawHill,1996.
F.HKulhawy,P.W.Mayne,ManualonEstimatingSoilPropertiesforFoundationDesign,ElectricPower ResearchInstitute,1990.
Holtec,DryStoragePositionPaperDS-338,Revision1,June23,2010.
Holtec,HI-STORMUMAXFSARRev.6