Letter Sequence Other |
---|
|
|
MONTHYEARCP-202100065, Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2021-05-11011 May 2021 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b Project stage: Request ML21166A3632021-06-15015 June 2021 NRR E-mail Capture - Comanche Peak - Draft Supplemental Information Request - License Amendment Request to Adopt TSTF-505, Rev 2 Project stage: Draft Other ML21166A3382021-06-22022 June 2021 Supplemental Information Needed for Acceptance of Requested Licensing Action LAR to Adopt TSTF-505, Rev. 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b Project stage: Acceptance Review CP-202100394, Supplement to License Amendment Request (LAR) 20-0062021-07-13013 July 2021 Supplement to License Amendment Request (LAR) 20-006 Project stage: Supplement ML21211A0012021-07-29029 July 2021 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request Regarding Adoption of TSTF-505, Revision 2 Project stage: Acceptance Review ML21222A0332021-08-0909 August 2021 NRR E-mail Capture - Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan and Setup of Online Document Access (L-2021-LLA-0085) Project stage: Other ML21300A1342021-10-27027 October 2021 NRR E-mail Capture - Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan Update and Audit Questions (L-2021-LLA-0085) Project stage: Other CP-202200006, (CPNPP) - Second Supplement to License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended.2022-02-17017 February 2022 (CPNPP) - Second Supplement to License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended. Project stage: Supplement ML22083A0262022-03-23023 March 2022 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Request to Adopt TSTF 505 Revision 2 Project stage: RAI CP-202200123, (CPNPP) - License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times.2022-03-29029 March 2022 (CPNPP) - License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times. Project stage: Request CP-202200205, (CPNPP) - License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - Rtstf.2022-05-12012 May 2022 (CPNPP) - License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - Rtstf. Project stage: Request ML22152A0412022-06-10010 June 2022 Summary of Regulatory Audit License Amendment Request to Revise TS to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b Project stage: Other CP-202200273, Third Supplement to License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative2022-07-20020 July 2022 Third Supplement to License Amendment Request (LAR) 20-006 Application to Revise Technical Specifications to Adopt Risk Informed Completion Times, TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative Project stage: Supplement ML22192A0072022-08-22022 August 2022 Issuance of Amendment Nos. 183 and 183 Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-505, Revision 2 Project stage: Approval 2021-08-09
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24025A0172024-01-22022 January 2024 NRC Request for Concurrence with Endangered Species Act Determinations for Comanche Peak License Renewal, Issuance of Draft Supplemental Environmental Impact Statement, and Opportunity for Public Comment ML24019A0742024-01-19019 January 2024 NRR E-mail Capture - Comanche Peak - Draft Request for Additional Information - License Amendment Request to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator ML24008A2492023-12-18018 December 2023 Texas Shpo Response for Comanche Peak Deis Review and Comment ML23311A2202023-11-20020 November 2023 NRC to Fws, NRC Request for Concurrence with Endangered Species Act Determinations for Comanche Peak License Renewal, Issuance of Draft Supplemental Environmental Impact Statement, and Opportunity for Public Comment (Consultation Code: 2023 ML23255A2882023-09-12012 September 2023 NRR E-mail Capture - Comanche Peak - Acceptance of Request for Exemption from 10 CFR 50.71(e)(4) Final Safety Analysis Update Schedule ML23256A1492023-09-11011 September 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 4 ML23226A0072023-08-11011 August 2023 NRR E-mail Capture - Comanche Peak 1 and 2 Audit Plan - License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML23188A0442023-07-0707 July 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 3 ML23181A0722023-06-29029 June 2023 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML23181A0202023-06-29029 June 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 2 ML23172A0152023-06-20020 June 2023 NRR E-mail Capture - Re Comanche Peak - Acceptance of License Amendment Request Regarding General Design Criterion 5 of Appendix a to 10 CFR Part 50 and Regulatory Guide 1.81 ML23167A0222023-06-14014 June 2023 Email: Request for Additional Information (RAI) Letter for the Review of the Comanche Peak Initial License Renewal Application, Set 1 ML23145A2332023-05-25025 May 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Confirmation of Information - Set 2 ML23143A1382023-05-23023 May 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Confirmation of Information - Set 1 ML23139A0802023-05-18018 May 2023 NRR E-mail Capture - Comanche Peak Draft Supplemental Information Request - License Amendment Request Regarding General Design Criterion 5 of Appendix a to 10 CFR Part 50 and Regulatory Guide 1.81 ML23138A1522023-05-18018 May 2023 Lr Docs - (External_Sender) Comanche Peak Nuclear Power Plants ML23135A9132023-05-15015 May 2023 NRR E-mail Capture - Comanche Peak - Draft Supplemental Information Request - License Amendment Request to 10 CFR 50.69 ML23131A2932023-05-11011 May 2023 Lr Docs - License Renewal for Comanche Peak Nuclear Power Plant, Units 1 and 2 ML23128A1612023-05-0808 May 2023 NRR E-mail Capture - Comanche Peak Nuclear Power Plant, Units 1 and 2, Beaver Valley Power Station, Unit Nos. 1 and 2, Davis-Besse Nuclear Power Station, Unit 1, and Perry Nuclear Power Plant, Unit No. 1 - Acceptance of Requested Licensing ML23110A7122023-04-20020 April 2023 NRR E-mail Capture - Comanche Peak - Verbal Authorization of Proposed Alternative RV-1 (L-2023-LLR-0019) ML23103A4682023-04-11011 April 2023 NRR E-mail Capture - Comanche Peak Request for Additional Information - License Amendment Request to Apply the Westinghouse Full Spectrum Loss of Coolant Accident Evaluation Model ML23086B9852023-03-27027 March 2023 NRR E-mail Capture - Comanche Peak Draft Request for Additional Information - Request to Apply the Westinghouse Full Spectrum Loss of Coolant Accident Evaluation Model ML23061A1612023-03-0202 March 2023 E-mail from David Griggs Regarding Submission to NRC Electronic Information Exchange on 03/01/2023 for Citizens for Fair Utility Regulation in Comanche Peak Proceeding ML23032A3842023-02-0101 February 2023 LRA On-Site Audit Needs List ML23214A0192023-01-30030 January 2023 (External_Sender) Request to Broaden Extended Deadline to the General Public (with Attachments) - C3 ML23214A0202023-01-29029 January 2023 (External_Sender) Requesting a Deadline Extension on NRC-2002-0183, Comanche Peak License Renewal - C2 ML23214A0182023-01-26026 January 2023 (External Sender) NRC-2022-0183-0003 (with Attachment) - C6 ML23214A0162023-01-24024 January 2023 (External Sender) EPA Scoping Comment Letter for the Comanche Peak Nuclear Power Plant License Renewal (with Attachment) - C8 ML23214A0142023-01-23023 January 2023 (External Sender) Docket NRC-2022-0183 Comanche Peak Nuclear Power Plant Renewal (with Attachment) - C1 ML23214A0172023-01-17017 January 2023 (External Sender) NRC License Extension? No! ML23214A0132023-01-17017 January 2023 (External Sender) Docket Id NRC-2022-0183, Request for Extension of License for Comanche Peak, Comment for Environmental Scoping - C9 ML23214A0122023-01-13013 January 2023 (External Sender) Correction to Comment Submitted 01-13-23 - C11 ML22362A0992022-12-28028 December 2022 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Apply Westinghouse Fsloca Evaluation Model ML22362A0972022-12-28028 December 2022 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Adopt WCAP-17661-P-A, Revision 1, Improved RAOC and CAOC Fq Surveillance Technical Specifications, ML22325A2742022-11-21021 November 2022 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22318A3102022-11-10010 November 2022 NRR E-mail Capture - Comanche Peak - Draft Request for Additional Information - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22237A2842022-08-25025 August 2022 CPNPP 2022 EP Program Inspection RFI Hjs 08252022 ML22230B1092022-08-17017 August 2022 NRR E-mail Capture - Comanche Peak Unit 2 - Request for Additional Information - 2RE19 Inspection Summary Report for Steam Generator Tubing ML22229A0792022-08-17017 August 2022 NRR E-mail Capture - Comanche Peak - Acceptance of Requested Licensing Action - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22220A1942022-08-0808 August 2022 NRR E-mail Capture - Comanche Peak Unit 2 - Draft Request for Additional Information - 2RE19 Inspection Summary Report for Steam Generator Tubing ML22133A0472022-05-13013 May 2022 July 2022 Emergency Preparedness Exercise Inspection - Request for Information ML22083A0262022-03-23023 March 2022 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Request to Adopt TSTF 505 Revision 2 ML22031A2122022-01-31031 January 2022 NRR E-mail Capture - Comanche Peak - Acceptance of Requested Licensing Action - Proposed Alternative to Extend the Snubber Inservice Program Third Interval ML21300A1342021-10-27027 October 2021 NRR E-mail Capture - Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan Update and Audit Questions (L-2021-LLA-0085) ML21286A7912021-10-13013 October 2021 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Request to Adopt TSTF-577 Revision 1 ML21272A2002021-09-29029 September 2021 NRR E-mail Capture - Comanche Peak Unit 2 - Upcoming Steam Generator Tube Inservice Inspection (L-2021-NFO-0013) ML21270A1632021-09-27027 September 2021 NRR E-mail Capture - Comanche Peak - Acceptance of Quality Assurance Program Change Request Regarding Internal Audit Frequency ML21253A2242021-09-0909 September 2021 Request for Information Occupational Radiation Safety Inspection (71124.01, 71124.02, and 71151) from 10/18-22/2021 ML21252A0062021-08-26026 August 2021 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request Regarding Adoption of TSTF-577, Revised Frequencies for Steam Generator Tube Inspections 2024-01-22
[Table view] |
Text
From: Galvin, Dennis Sent: Monday, August 9, 2021 6:26 PM To: Jack Hicks (Jack.Hicks@luminant.com)
Cc: Struble, Garry
Subject:
Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan and Setup of Online Document Access (L-2021-LLA-0085)
Attachments: Comanche Peak - TSTF 505 -Audit Plan - Portal Request 2021-08-09.pdf
Dear Mr. Hicks,
By letter dated May 11, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML (ML21131A233) as supplemented by letter dated July 13, 2021 (ML21194A078), Vistra Operations Company, LLC (Vistra OpCo, the licensee) submitted a license amendment request (LAR) regarding Comanche Peak Nuclear Power Plant Units 1 and 2 (Comanche Peak). The proposed amendment would revise Technical Specification (TS) requirements to permit the use of risk informed completion times for actions to be taken when limiting conditions for operation are not met. The proposed changes are based on TSs Task Force Traveler (TSTF) 505, Revision 2, Provide Risk Informed Extended Completion Times -
RITSTF Initiative 4b, dated July 2, 2018 (ADAMS Accession No. ML18183A493). The U.S.
NRC issued a final model safety evaluation (SE) approving TSTF 505, Revision 2, on November 21, 2018 (ADAMS Accession No. ML18269A041).
The U.S. Nuclear Regulatory Commission (NRC) staff has determined that a regulatory audit would support its review of the proposed license amendment. The audit will be conducted via online access to non-docketed information set up by the licensee and via webinar. The enclosed audit plan addresses the request for online access to documents. The audit plan for the webinar, including audit questions, will be provided separately. The licensee is requested to provide online access to specific NRC staff and to be read-only (i.e., to establish measures to prevent the downloading, copying, printing, or otherwise storing of any documents). The audit information the NRC staff determines to be necessary to support the development of the NRC staffs safety evaluation will be requested to be submitted on the docket following the webinar portion of the audit.
If you have any questions, please contact me at (301) 415-6256.
Respectfully, Dennis Galvin Project Manager U.S Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Operating Reactor Licensing Licensing Project Branch 4 301-415-6256 Docket No. 50-445, 50-446
Hearing Identifier: NRR_DRMA Email Number: 1310 Mail Envelope Properties (SA1PR09MB81118ED6702D62F16846C532FBF69)
Subject:
Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan and Setup of Online Document Access (L-2021-LLA-0085)
Sent Date: 8/9/2021 6:25:52 PM Received Date: 8/9/2021 6:25:00 PM From: Galvin, Dennis Created By: Dennis.Galvin@nrc.gov Recipients:
"Struble, Garry" <Garry.Struble@luminant.com>
Tracking Status: None "Jack Hicks (Jack.Hicks@luminant.com)" <Jack.Hicks@luminant.com>
Tracking Status: None Post Office: SA1PR09MB8111.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2116 8/9/2021 6:25:00 PM Comanche Peak - TSTF 505 -Audit Plan - Portal Request 2021-08-09.pdf 120423 Options Priority: Normal Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
AUDIT PLAN LICENSE AMENDMENT REQUEST TO ADOPT RISK-INFORMED EXTENDED COMPLETION TIMES VISTRA OPERATIONS COMPANY, LLC COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 DOCKET NOS. 50-445 AND 50-446 I. BACKGROUND By letter dated May 11, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML (ML21131A233) as supplemented by letter dated July 13, 2021 (ML21194A078), Vistra Operations Company, LLC (Vistra OpCo, the licensee) submitted a license amendment request (LAR) regarding Comanche Peak Nuclear Power Plant Units 1 and 2 (Comanche Peak). The proposed amendment would revise Technical Specification (TS) requirements to permit the use of risk informed completion times for actions to be taken when limiting conditions for operation are not met. The proposed changes are based on TSs Task Force Traveler (TSTF) 505, Revision 2, Provide Risk Informed Extended Completion Times -
RITSTF Initiative 4b, dated July 2, 2018 (ADAMS Accession No. ML18183A493). The U.S.
NRC issued a final model safety evaluation (SE) approving TSTF-505, Revision 2, on November 21, 2018 (ADAMS Accession No. ML18269A041).
The audit will be conducted via online access to non-docketed information set up by the licensee and via webinar. This audit plan addresses the request for online access to documents. The audit plan for the webinar, including audit questions, will be provided separately.
II. REGULATORY AUDIT BASES The basis of this remote audit is the licensees LAR for Comanche Peak, and the Standard Review Plan (SRP) Section 19.2, Review of Risk Information Used to Support Permanent Plant-Specific Changes to the Licensing Basis: General Guidance (ADAMS Accession No. ML071700658).
The remote audit will be performed consistent with NRC Office of Nuclear Reactor Regulation Office Instruction LIC-111, Revision 1, Regulatory Audits, dated October 31, 2019 (ADAMS Accession No. ML19226A274). An audit was determined to be the most efficient approach toward a timely resolution of issues associated with this LAR review, since the staff will have an opportunity to minimize the potential for multiple rounds of requests for additional information (RAIs) and ensure no unnecessary burden will be imposed by requiring the licensee to address issues that are no longer necessary to make a safety determination.
Enclosure
III. PURPOSE AND SCOPE The purpose of the audit is to gain a more detailed understanding of licensees Risk Informed Completion Time (RICT) program and its application to the TSs completion times as proposed in the LAR. This will support NRC staff preparation of questions to be addressed during the future audit interactions, anticipated to be conducted by webinar. The NRC staff will review internal events and fire PRA and the risk informed approach for establishing extended completion times.
The areas of focus for the regulatory audit are the information contained in the licensees submittal, the enclosed audit information needs, and all associated and relevant supporting documentations (e.g., methodology, process information, calculations, etc.). The relevant supporting documents are identified below.
IV. INFORMATION AND OTHER MATERIAL NECESSARY FOR THE REGULATORY REMOTE AUDIT The following documentation should be available to the audit team:
- 1. CN-RAM-13-038, Revision 3, Qualitative Screening, Quantitative Screening, Quantification, and Uncertainty Analysis for CPNPP Fire PRA, December 2019.
- 2. CN-RAM-20-003, Revision 0, Comanche Peak High Winds PRA Hazard Analysis, October 2020.
- 3. CN-RAM-20-016, Revision 0, Comanche Peak Nuclear Power Plant PRA Model Integration for TSTF-505, January 2021.
- 4. LTR-RAM-11-11-038, RG 1.200 PRA Peer Review Against the ASME/ANS PRA Standard Requirements for the Comanche Peak Nuclear Power Plant Probabilistic Risk Assessment, Westinghouse Electric Co.
- 5. LTR-RAM-15-48, Revision 0, Review of SRs not Met at Capability Category II and Resolution of Peer Review F&Os from the 2011 Internal Events and Internal Flooding PRA Peer Review for the Comanche Peak Nuclear Power Plant, Westinghouse Electric Co.
- 6. LTR-RAM-15-71, Revision 0, Independent Review and Resolution of Inconsistencies in the 2011 Internal Events and Internal Flooding PRA Peer Review Report for the Comanche Peak Nuclear Power Plant, Westinghouse Electric Co.
- 7. LTR-RAM-20-45, Revision 0, Seismic Hazard Analysis to Support Comanche Peak RICT LAR, May 2020.
- 8. LTR-RAM-20-99, Revision 0, High Wind Hazard Analysis to Support Comanche Peak RICT LAR, November 2020.
- 9. PWROG-14001-P-A, Revision 1, PRA Model for the Generation III Westinghouse Shutdown Seal, December 2017.
- 10. PWROG-15103-P, Revision 0, Peer Review of the Comanche Peak Internal Fire Probabilistic Risk Assessment, Pressurized Water Reactors Owners Group, June 2016.
- 11. PWROG-18060-P, Revision 0, Independent Assessment of Facts & Observations Closures of the Comanche Peak Probabilistic Risk Assessment, Pressurized Water Reactors Owners Group, January 2019.
- 12. R&R-PN-008A, Revision 5, Internal Initiating Events Data Analysis, Comanche Peak Nuclear Power Plant, November 2016.
- 13. R&R-PN-021, Revision 5, Internal Flooding Analysis, May 2019.
- 14. R&R-PN-022, Revision 5, Level 1 Internal Events Quantification, October 2016.
- 15. R&R-PN-035, Revision 5, Level 2 Internal Events Quantification, November 2016
- 16. R&R-PN-041, Revision 5, Sensitivity and Uncertainty, January 2019
- 17. R&R-PN-46, Revision 5, Configuration Risk Monitor for Risk-Informed Completion Times, January 2021.
- 18. R&R-PN-205, Revision 5, Screening and Conservative Analysis for Other External Hazards, October 2020.
- 19. STA-604, Configuration Risk Management and Work Scheduling
- 20. STA-762, Risk Informed Completion Time Implementation
- 21. STI-762.01, Risk-Informed Completion Time Implementation
- 22. STI-762.02, Risk-Informed Completion Times - PRA model Configuration Control
- 23. PRA Uncertainty Notebooks for internal events, internal flooding and fire
- 24. PRA success criteria Notebooks
- 25. Documentation supporting the example RICT calculations presented in LAR Enclosure 1 Table E1-2 V. AUDIT TEAM The members of the audit team are anticipated to be:
- Milton Valentin, APLC, NRC (Milton.Valentin@nrc.gov)
- Wesley Wu, APLC, NRC (De.Wu@nrc.gov)
- Steven Short, Contractor, PNNL (Steve.Short@pnnl.gov)
VI. SPECIAL REQUESTS The NRC staff would like online access to the documents listed above in Section IV that allows the NRC staff and contractors to access documents remotely. Additional documents may be identified as the review progresses. NRC staff and contractors online access should be terminated October 31, 2022.
Online access to documents is to be limited to specific NRC staff and contractors (e.g., based on NRC or contractor e-mail addresses or the use of passwords which will only be assigned to NRC or contractor staff directly involved in the LAR review on a need-to-know basis), and to be read-only (i.e., to establish measures to prevent the downloading, copying, printing, or otherwise storing of any documents). The conditions associated with the online access of documents must be maintained throughout the review process. The NRC staff who should be granted access to the portal are those listed in the Team Assignments section. All other communications should be coordinated with the NRC project manager.
VII. DELIVERABLES An audit summary, which will be public, will issued at the completion of the audit. If the NRC staff identifies information during the webinar portion of the audit that is needed to support its regulatory decision, the staff will issue RAIs to the licensee after the completion of the webinar portion of the audit.