July 14, 2021 Mr. David P. Rhoades Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
CLINTON POWER STATION, UNIT NO. 1 - CORRECTION TO AMENDMENT NO. 238 ISSUED JUNE 28, 2021, RE: TECHNICAL SPECIFICATIONS TASK FORCE TRAVELER TSTF-505, REVISION 2, PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B (EPID L-2020-LLA-0097)
Dear Mr. Rhoades:
By letter dated June 28, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21132A288), the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 238 to Facility Operating License No. NPF-62 for the Clinton Power Station, Unit No. 1. The amendment was in response to your application dated April 30, 2020 (ADAMS Accession No. ML20121A178) as supplemented by letters dated November 24, 2020 (ADAMS Accession No. ML20329A433) and March 23, 2021 (ADAMS Accession No. ML21082A268).
Subsequent to issuance of the amendment, your staff informed me that there were unintended characters on issued technical specification (TS) page 3.5-12 and an unintended underscore on issued TS page 3.3-2. The attached TS pages correct these unintended changes. These corrections do not change any of the conclusions in the safety evaluation associated with the issuance of the amendment.
If you have any questions, please contact me at 301-415-6606 or Joel.Wiebe@nrc.gov.
Sincerely,
/RA/
Joel S. Wiebe, Senior Project Manager Plant Licensing Branch III Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-461
Enclosure:
Corrected TS pages cc: Listserv
ENCLOSURE CLINTON POWER STATION, UNIT NO. 1 CORRECTED TS PAGES FOR AMENDMENT NO. 238
RPS Instrumentation 3.3.1.1 CLINTON 3.3-2 Amendment No. 238 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME D.
Required Action and associated Completion Time of Condition A, B, or C not met.
D.1 Enter the Condition referenced in Table 3.3.1.1-1 for the channel.
Immediately E.
As required by Required Action D.1 and referenced in Table 3.3.1.1-1.
E.1 Reduce THERMAL POWER to < 33.3% RTP.
8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> F.
As required by Required Action D.1 and referenced in Table 3.3.1.1-1.
F.1 Reduce THERMAL POWER to < 21.6% RTP.
8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> G.
As required by Required Action D.1 and referenced in Table 3.3.1.1-1.
G.1 Be in MODE 2.
8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> H.
As required by Required Action D.1 and referenced in Table 3.3.1.1-1.
H.1 Be in MODE 3.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> I.
As required by Required Action D.1 and referenced in Table 3.3.1.1-1.
I.1 Initiate action to fully insert all insertable control rods in core cells containing one or more fuel assemblies.
Immediately
RCIC System 3.5.3 CLINTON 3.5-12 Amendment No. 238 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV)
WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC)
SYSTEM 3.5.3 RCIC System LCO 3.5.3 The RCIC System shall be OPERABLE.
APPLICABILITY:
MODE 1, MODES 2 and 3 with reactor steam dome pressure > 150 psig.
ACTIONS
NOTE-------------------------------------
LCO 3.0.4.b is not applicable to RCIC.
CONDITION REQUIRED ACTION COMPLETION TIME A. RCIC System inoperable.
A.1 Verify by administrative means High Pressure Core Spray System is OPERABLE.
AND A.2 Restore RCIC System to OPERABLE status.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 14 days OR In accordance with the Risk Informed Completion Time Program B. Required Action and associated Completion Time not met.
B.1 Be in MODE 3.
AND B.2 Reduce reactor steam dome pressure to 150 psig.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 36 hours