Text
Program Management Office 1000 Westinghouse Drive, Suite 172 Cranberry Township, Pennsylvania 16066 Project 694 Docket 99902037 June 22, 2021 OG-21-122 U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852
Subject:
PWR Owners Group PWROG Comments on the NRC Draft Safety Evaluation for PWROG-19047-P/NP, Revision 0, North Anna Units 1 and 2 Reactor Vessels Low Upper-Shelf Fracture Toughness Equivalent Margin Analysis (PA-MSC-1481)
Reference:
Draft Safety Evaluation by the Office of Nuclear Reactor Regulation for the Pressurized Water Reactor Owners Group (PWROG Topical Report PWROG-19047-P/NP, Revision 0, North Anna Units 1 and 2 Reactor Vessels Low Upper-Shelf Fracture Toughness Equivalent Margin Analysis (EPID: L-2020-TOP-0028)
The purpose of this letter is to transmit a table with the PWR Owners Group comments on the Draft Safety Evaluation (DSE) (Enclosure 1) and a markup of the DSE that includes the comments (Enclosure 2).
The proprietary information from PWROG-19047-P included in the NRC DSE is indicated in bold brackets in Enclosure 2. The PWROG requests continued withholding from public disclosure in accordance with the affidavits originally transmitted by OG-20-167, PWR Owners Group Submittal of PWROG-19047-P/NP, Revision 0, North Anna Units 1 and 2 Reactor Vessels Low Upper-Shelf Fracture Toughness Equivalent Margin Analysis (PA-MSC-1481).
The PWROG requests that the Staff revise the DSE to address these comments and contact the PWROG with any questions regarding the PWROG comments.
Correspondence related to this transmittal should be addressed to:
Mr. W. Anthony Nowinowski, Executive Director PWR Owners Group, Program Management Office Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066
U.S. Nuclear Regulatory Commission June 22, 2021 OG-21-122 Page 2 of 2 Electronically approved records are authenticated in the electronic document management system If you have any questions, please do not hesitate to contact me at (602) 999-2080 or Mr. W. Anthony Nowinowski, Executive Director of the PWR Owners Group, Program Management Office at (412) 374-6855.
Sincerely yours, Michael Powell Chairman and COO PWR Owners Group DSM/am
- Comments on the Draft Safety Evaluation for PWROG-19047-P and PWROG-19047-NP, Revision 0
- Markup of the Draft Safety Evaluation for PWROG-19047-P and PWROG-19047-NP, Revision 0 cc:
PWROG Steering Committee Representatives PWROG Management Committee Representatives PWROG PMO L. Fields, US NRC T. Zalewski, Westinghouse G. Hall, Westinghouse J. Andrachek, Westinghouse M. Higby, Westinghouse R. Stewart, Framatome A. Nana, Framatome M. Rinckel, Framatome