May 20, 2021 1
Advisory Committee on Reactor Safeguards (ACRS)
Future Plant Designs Subcommittee 10 CFR Part 53 Licensing and Regulation of Advanced Nuclear Reactors Subparts A and F Preliminary Proposed Rule Language and White Paper on Human Factors
Agenda 9:30am - 9:40am Welcome / Introductions / Logistics / Goals 9:40am - 11:15am White Paper - Risk-Informed and Performance-Based Human-System Considerations for Advanced Reactors 11:15am - 1:00pm Subpart A - General Provisions 1:00pm - 2:00pm Lunch Break 2:00pm - 4:00pm Subpart F - Section 53.700, Operational Objectives and Controls on Equipment 4:00pm - 5:30pm Subpart F - Section 53.800, Programs 5:30pm - 6:00pm Discussion/Closing Remarks 2
Plant Documents (Systems, Procedures, etc.)
Analyses (Prevention, Mitigation, Compare to Criteria)
Plant/Site (Design, Construction, Configuration Control)
Retirement Staffing &
Human Factors Configuration Control Surveillance Maintenance Operation Construction/
Manufacturing Construction Siting Design and Analysis LB Documents (Applications, SAR, TS, etc.)
NRC Staff Plan to Develop Part 53 Project Life Cycle System
& Component Design Analysis Requirements Subpart B Subpart C Subpart D Subpart E Subpart F Subpart G Subparts H & I Safety Categorization
& Special Treatment External Hazards Site Characteristics Environmental Considerations Ensuring Capabilities/
Reliabilities Change Control Environmental Considerations Programs Security, EP Facility Safety Program 3
Requirements Definition Safety Objectives Safety Criteria Safety Functions Other Subpart J Admin & Reporting Clarify Controls and Distinctions Between Subpart A General Provisions
NRC Staff Engagement Plan 4
Concept/Introduction Discussion Interim Staff Resolution Framework Safety Criteria Design Siting Construction Operations Decommissioning Licensing General/Admin Sept 20 Nov 20 Dec 20 Jan 21 Feb 21 Mar 21 Apr 21 May 21 Jun 21 Jul 21 Consolidated Technical Sections Aug 21 Consolidated Technical Sections Sept 21 Oct 21 Nov 21 Consolidated Rulemaking Package Dec 21 Jan 22 ACRS Full Committee Feb 22 Mar 22 Apr 22 May 22 Draft Proposed Rulemaking Package to the Commission Jun 22 Jul 22 Aug 22 Sept 22 Oct 22 ACRS Interactions
Risk-Informed and Performance-Based Human-System Operation Considerations for Advanced Reactors NRR - Division of Advanced Reactors and Non-power Production and Utilization Facilities NRR - Division of Reactor Oversight May 20, 2021
Agenda
- Background
- Nexus to 10 CFR 53
- White Paper Considerations - Overview
- Next Steps
- Questions/Comments 6
NEIMA Nuclear Energy Innovation and Modernization Act (NEIMA) requires the NRC to complete a rulemaking to establish a technology-inclusive, regulatory framework for optional use for commercial advanced nuclear reactors by 2027.
NRC currently developing 10 CFR 53: "Licensing and Regulation of Advanced Nuclear Reactors."
Supporting Guidance
- In some cases, guidance in support of proposed rule may be the driving factor to meet technology-inclusive, performance-based criteria that define a modern risk-informed graded approach.
- Development of key guidance to 10 CFR 53 - Draft White Paper guidance to be discussed today was developed under that premise.
7 Background
White Paper: Risk-Informed and Performance-Based Human-System Operation Considerations for Advanced Reactors*
- Supports Subpart F: Operations
- Presented as Key Guidance to ACRS subcommittee on March 17, 2021
- Topics address diverse and novel operational characteristics, including automation of operations, staffing and qualifications of operations personnel, evolution in control room concepts, and the application of human factors engineering (HFE).
- Draft white paper released to begin external stakeholder interactions
- Released March 25, 2021 (ADAMS Accession No. ML21069A003) 8 Key Guidance
Subpart F Operations preliminary rule language
- Primary purpose of this paper is to inform and support Part 53 rulemaking by proposing guidance related to operations (subpart F).
- Secondary goal is to facilitate the consistent treatment of advanced reactor applications that are received prior to Part 53 being finalized.
- Goal is technology-inclusive, scaled review approaches to the extent practical.
9 Nexus to 10 CFR Part 53
Main Topics
- The regulatory framework for advanced reactors should be capable of addressing novel operational concepts for a wide variety of advanced reactor technologies.
- Some advanced reactor designs may present very low radiological risk and requirements in the current regulatory framework for operation of large light water reactors (LWRs) may be unnecessary for reasonable assurance of safety.
- The development of a risk-informed, performance-based, and technology-inclusive regulatory framework that appropriately considers the role of humans and human-system integration is warranted for advanced reactors.
10 White Paper Considerations
New Technologies and Safety Characteristics
- The preceding decades have witnessed evolutionary changes in areas like passive safety and modular construction.
- Technologies that are under various stages of development include small modular reactors (SMRs), non-LWRs, and fusion-based technologies.
- Such technologies warrant careful consideration of design attributes that represent departures from large LWR designs.
- The NRC recognizes the desirability of attributes such as simplified safety features of a passive or inherent nature, reductions in required human actions, incorporation of defense-in-depth (DID), and minimization of the risks associated with severe accidents in advanced reactor designs.
11 White Paper Considerations
- Advanced reactors could vary in size from very large to very small; such variations are expected to have potential implications for both source term sizes and accident consequences.
- Accident source terms can serve as a measure of the efficacy of mitigation features.
- Advanced reactor designs may present low potential accident consequences.
- Limiting the hazard posed by a reactor facility reduces the potential for accident consequences and is the most reliable means of ensuring safety.
12 Smaller Source Term Sizes and Reduced Accident Consequences White Paper Considerations
- Passive safety features and inherent safety characteristics can influence the role of personnel at advanced reactors facilities.
- Passive safety features tend to place humans into a DID role.
- While passive safety features can still fail under certain conditions, inherent safety characteristics can be considered to be absolutely reliable.
- The incorporation of inherent safety characteristics, passive safety features, and automated safety systems influence the concept of operations and can affect the emphasis placed on the HFE aspects of an application review.
13 Passive Safety Features and Inherent Characteristics White Paper Considerations
- Automation is implemented in levels that span from manual to autonomous operation.
- Autonomous operation (full automation) has the potential to support unattended reactor operations.
- Even in an autonomous design, there may still exist a need for humans to implement manual operations under certain circumstances, such as for DID.
- Automation generally enhances operational performance, however other operational effects must be considered as well (e.g., operators losing manual control proficiency).
14 Automation of Plant Operations White Paper Considerations
- Advanced reactor designers may desire to incorporate load-following capabilities into their designs.
- Load-following where a grid control center can directly adjust plant output is not currently practiced by commercial nuclear facilities in the U.S. because the practice is precluded by existing NRC regulations; however, that is not the case internationally.
- A nuclear power plant needs to be able to refuse load-following requests when complying with such requests would violate technical specifications (TS) or result in unsafe conditions.
15 Load Following White Paper Considerations
- The NRC has had a long-standing policy of ensuring that DID is incorporated into the design and operation of nuclear power plants.
- The key principles of note within the present context are that DID approaches should:
oNot rely solely on a single operational feature oNot rely excessively upon human actions (or programs).
- The role of humans in DID at advanced reactors is an area that may need further development.
16 DID and Advanced Reactor Operations White Paper Considerations
- The NRC staff previously recognized the limitations of the prescriptive requirements of 10 CFR 50.54(m) and developed NUREG-1791 in order to allow increased flexibility to LWRs and provide guidance for assessing exemptions to the regulations in 10 CFR 50.54(m).
- Licensing future applications for advanced reactors by exemption from prescriptive requirements may not be a practical long-term regulatory framework.
- An alternative means that is not reliant upon NUREG-1791 may be beneficial, especially if such a means were to rely upon analyses that can be scaled with the risk of the facility.
17 Staffing White Paper Considerations
- The NRC has been licensing reactor operators since the 1950s.
- The Atomic Energy Act of 1954, as amended (AEA), requires the NRC to prescribe uniform operator licensing conditions.
- All license exams are approved and administered by the staff.
- Advanced reactor operational concepts may not align well with the existing power reactor operator licensing framework.
- Examples of appropriate changes for advanced reactors may include allowances for varying licensing examination scope on a facility-specific basis and modified simulator requirements.
- A revised approach to operator licensing should flexibly and efficiently address a wide variety of advanced reactor designs.
18 Operator Licensing White Paper Considerations
- Staffing at power reactors also includes the STA position.
Unlike licensed operators, STA requirements are primarily rooted in Commission policy, and not regulation or statute.
- The current policy is that, on each shift, there should be at least one person on duty who has a degree in physical science, engineering, engineering technology, or a PE license.
- The function of this person is to provide independent engineering expertise, accident assessment, and technical advice to the main control room operators.
- The elimination of the STA position at a power reactor facility would be a departure from existing Commission policy, as well as from longstanding agency and industry practice.
19 Shift Technical Advisor (STA) Position White Paper Considerations
- The Nuclear Waste Policy Act of 1982, as amended (NWPA), directs the NRC to establish regulations for the training and qualifications of nuclear power plant operators, supervisors, technicians and other operating personnel.
- The NWPA also directs the NRC to establish requirements for simulator training, requalification examinations, operating tests, and instructional requirements.
- The Systems Approach to Training (SAT) plays a central role in current nuclear training and qualification programs.
- The SAT process is generic in nature and can be adapted to any reactor technology, including those associated with essentially any foreseeable advanced reactor designs.
20 Training White Paper Considerations
- The application of HFE in the design of nuclear power plant control rooms is required under existing post-Three Mile Island regulations.
- Current HFE reviews typically focus on the human-system interfaces (HSIs) located within control rooms.
- Moving forward should include examining how HFE reviews can be implemented most effectively for advanced reactors.
- New approaches, such as the application of scalable HFE review processes and thinking beyond the confines of traditional control rooms, should be considered.
- A Concept of Operations can be valuable in gaining the design understanding necessary to conduct appropriate HFE reviews.
21 Human Factors Engineering White Paper Considerations
- Some advanced reactor facilities may wish to not utilize traditional control rooms in their designs.
- Requirements addressing matters associated with control rooms will need to be revisited in Part 53 with an understanding that the functions involved may become decentralized in an advanced reactor facility.
- HFE requirements will essentially need to be able to follow important functions if they are relocated outside of a traditional control room.
- It may also be necessary to account for the potential emergence of functions that have no precedent within traditional control rooms as well.
22 The Evolving Concept of the Control Room White Paper Considerations
- For a fully autonomous advanced reactor design, it should be noted that the existing regulatory framework also assigns certain responsibilities and authorities to licensed operators. A key example are the requirements of 10 CFR 50.54(x) and (y) for departures from license conditions.
- Beyond this, there are numerous other licensed operator administrative responsibilities and authorities that are both important to safety and derived from regulatory requirements; such responsibilities and authorities would need to be addressed as well.
oThese include compliance with TSs, operability determinations, NRC notifications, emergency declarations, and radiological release limit compliance.
23 Additional Organizational Considerations; No Licensed Operators White Paper Considerations
- The rule may recognize that staffing, training, operator licensing, and human factors are interrelated areas; diverse advanced reactor technologies necessitate integrating the review of these areas under a flexible approach.
- The rule may account for varying accident consequences in assessing staffing issues.
- The rule may require an HFE program adequate to ensure that personnel can understand plant status, take action to ensure safety, and perform other important technical and administrative functions with safety implications.
oHuman roles associated with the management and availability of plant-specific safety functions will need to be taken into account when considering HFE requirements.
24 White Paper alignment with 10 CFR 53 White Paper Considerations
- The rule may account for designs that do not utilize traditional control rooms.
- The rule will need to ensure that the operator licensing process accomplishes the following:
oCompliance with applicable statutory requirements (i.e.,
AEA and NWPA);
oConformance with accepted testing standards; oFacilitation of consistent and reliable licensing decisions by the NRC; oEfficient use of NRC and vendor/facility licensee resources; oProvision of reasonable assurance that operators will be able to manage plant-specific safety functions.
25 White Paper alignment with 10 CFR 53 (contd)
White Paper Considerations
- The rule may allow for consideration of innovative features intended to make new designs safer, while also accounting for uncertainties associated with new approaches.
- The rule may, in a non-prescriptive manner, require staffing levels needed to support safe operation and allow for the possibility of demonstrating that no human presence is necessary.
oThe rule may also prescribe minimal requirements that must be met to not use licensed operators at all.
- The rule may ensure that advanced reactor DID approaches do not rely exclusively upon a single operational feature or rely excessively upon human actions.
26 White Paper alignment with 10 CFR 53 (contd)
White Paper Considerations
- The rule may account for the possibility of load-following where the load changes themselves are controlled externally from a grid control center.
- The rule will need to require that sufficient information be submitted to facilitate reviews as outlined within these goals.
Examples of such information may include the following:
oThe Concept of Operations for the design; oFunctional Requirements Analyses describing the features, systems, and human actions relied upon for safety; oA staffing plan, with supporting HFE-based analyses; oA SAT-based training program for relevant personnel.
27 White Paper alignment with 10 CFR 53 (contd)
White Paper Considerations
- The NRC staff has initiated work under contract with Brookhaven National Laboratory (BNL) to develop a method for scaling the scope and depth of HFE reviews for advanced reactors.
- The objective of this effort is to enable the staff to readily adjust the focus and level of staff HFE review efforts based upon factors such as risk insights and the unique characteristics of the design or facility operation.
- In the interim, the NRC staff also has the ability to adjust the scope of a NUREG-0711 HFE review on a case-by-case basis should a given license application warrant a reduction in the scope of an HFE-area technical review.
28 Solutions: Scalable HFE Reviews White Paper Considerations
To justify not using licensed operators, the applicant must demonstrate that adequate protection of the public health and safety will exist in the absence of any operator action for preventing or mitigating accidents. The following are examples of criteria that could potentially be used for assessing the acceptability of an advanced reactor design operating without using any licensed operators:
- 1. The accident analysis must demonstrate that radiological consequence criteria will be met without reliance on human actions for event mitigation, DID, or safe shutdown.
29 Solutions: Staffing Facilities Without Need for Licensed Operators White Paper Considerations
- 2. Safety of the design should rely upon inherent safety characteristics. Absent an operator presence, the absolute reliability of inherent safety characteristics would be key.
- 3. If not fully autonomous, the design should have sufficient autonomy to support safety without human action. If human action is needed for startup, it may be appropriate to:
- a. have a licensed operator conduct the reactor startup; or
- b. demonstrate the safety analyses bound all postulated errors by a non-licensed operator during a reactor startup (warranted because a non-licensed startup operators abilities would not provide the NRC staff with the same degree of assurance as those of a licensed operator).
30 Solutions: Staffing Facilities Without Need for Licensed Operators (Contd)
White Paper Considerations
- 4. License conditions could be established for the facility so that those administrative responsibilities with safety implications (e.g., Tech Spec compliance) that would otherwise have been allocated to licensed operators are reassigned (e.g., to a designated facility manager position).
- 5. For the STA position, the staff would need to engage with the Commission on a proposed departure from policy should an applicant propose a staffing plan that does not include on-shift engineering expertise. A key consideration would likely be the applicants ability to demonstrate that the results of staffing-related analyses remain adequate in the absence of the on-shift engineering expertise provided by an STA.
31 Solutions: Staffing Facilities Without Need for Licensed Operators (Contd)
White Paper Considerations
- A flexible process that advanced reactor vendors and licensees could use to develop an operator licensing exam program for their sites might consist of the following:
- 1. Job Task Analyses to identify knowledge, skills, and abilities related to the facilitys licensed operator role.
- 2. Training and evaluation methods would be selected using a SAT process, including determining exam composition.
- 3. A vendor or licensee would pilot the proposed exam.
- 4. Exams would be reviewed and administered by the NRC.
oA potential option would be for vendors and licensees to also administer their own license examinations.
32 Solutions: Scalable Approach to Operator Licensing Requirements White Paper Considerations
- There is currently no regulation requiring applicants to provide a Concept of Operations as part of applications.
- New designs will likely conceive of radically different Concepts of Operations for which the staff may have little or no prior understanding. Therefore, there may be a need to explicitly make the Concept of Operations a part of the content of applications under the proposed Part 53 rule.
- A description of the Concept of Operations will help the NRC staff to avoid confusion, understand and confirm to what extent a design relies on the humans for safe operation, determine the appropriate scope of the staff review, and reduce the need for Requests for Additional Information.
33 Solutions: Concept of Operations White Paper Considerations
- It may be appropriate for applicants to propose their own alternative staffing models. At a minimum, an HFE-based staffing analysis of sufficient scope and depth to allow for the NRC staff to adequately assess the acceptability of the proposed staffing levels would be needed.
- Alternative staffing models for advanced reactor applicants could be informed by the existing process of NUREG-1791.
- It may also be appropriate for the Part 53 rule to provide a prescriptive staffing model as an option for applicants that prefer not to conduct the staffing analyses needed to support an alternative, flexible staffing model.
34 Solutions: Staffing Analyses White Paper Considerations
- Applications are likely to need to contain specific information related to an HFE program and the related analyses (e.g.,
designs of control room HSIs or proposals for alternative staffing models would be expected to be informed by HFE principles).
- Part 53 may require advanced reactor applications to address the incorporation of state-of-the-art HFE principles more comprehensively than existing regulations require at present.
An advanced reactor HFE program should be adequate to ensure that humans can perform the full range of tasks necessary to ensure the continued availability of plant-specific safety functions; this may also extend to maintenance and testing activities related to plant safety functions.
35 Solutions: HFE Programs White Paper Considerations
Draft Part 53 Rule Language
- Prescriptive criteria for not using licensed operators
- Content of Applications; to address inclusion of the Concept of Operations and the HFE-related information needed to for advanced reactor applications.
- HFE and Operating License (OL) Integration - an overall objective in development of both rule language and guidance.
Regulatory Guidance
- Technology-Inclusive OL - efforts to create an ISG are underway via NRR/RES working group; national lab support is being pursued.
- Scalable HFE Reviews - efforts to create ISG underway via NRR/RES working group with national lab support (BNL).
The objectives are being addressed using the approach below 36 Next Steps
- Draft concepts in white paper meant to solicit feedback on key areas of advanced reactor operations. Final scope and guidance outcome will be determined in coming months.
- Well-defined and unambiguous criteria is critical for a performance-based, graded approach related to Operations.
Leveraging results of existing methodologies as part of an application (such as Licensing Modernization Project (LMP),
maximum hypothetical accident (MHA), deterministic insights, probabilistic risk assessment (PRA) insights, etc.) will be explored.
- White Paper concepts are intended for future 10 CFR 53 applicants, however, NRC may use the concepts described to inform proposed exemptions from Part 50/52 requirements for near-term applicants.
37 Final Thoughts White Paper Considerations
38 Next Steps White Paper: Risk-Informed and Performance-Based Human-System Operation Considerations for Advanced Reactors*
- Released March 25, 2021 (ADAMS Accession No. ML21069A003)
- Additional stakeholder interactions will follow in coming months. Industry feedback expected July 2021 timeframe.
- The NRC staff are evaluating resources/schedule to identify what areas of the guidance to prioritize.
- Initial discussions with national labs to assist with expertise
- White Paper guidance in final form will support development of proposed 10 CFR 53 rule language and regulatory guidance.
- Final form of guidance is still being evaluated. For example:
oInterim Staff Guidance oRegulatory Guide
Questions/Comments?
Jesse Seymour, NRR/DRO/IOLB/HFT Thank You!
Jesse.Seymour@nrc.gov
Human-System Operation Considerations Discussion 40
41 General Provisions and Definitions - Subpart A
Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 42
10 CFR Part 53 Subpart A Layout
- § 53.010 - Scope
- § 53.020 - Definitions
- § 53.040 - Written Communications
- § 53.050 - Deliberate Misconduct
- § 53.060 - Employee Protection
- § 53.070 - Completeness and Accuracy of Information
- § 53.080 - Specific Exemptions
- § 53.090 - Combining Licenses; Elimination of Repetition
- § 53.100 - Jurisdictional Limits
- § 53.110 - Attacks and Destructive Acts
- § 53.120 - Information Collection Requirements: Office of Management and Budget Approval 43
Subpart A - § 53.020 Definitions 44
- Advanced nuclear plant o
Advanced nuclear plant [or facility] means a utilization facility consisting of one or more advanced nuclear reactors [as defined in NEIMA] and associated co-located support facilities, which may include one or more reactor modules, [using nuclear fission, nuclear fusion, or accelerator-driven reactor technologies] that are used for producing power for commercial electric or other commercial purposes. The advanced nuclear plant includes the collection of sites, buildings, radionuclide sources, and structures, systems, and components for which a license is being sought under this part.
Definition of advanced nuclear reactor (NEIMA) o a nuclear fission or fusion reactor, including a prototype plant (as defined in sections 50.2 and 52.1 of title 10, Code of Federal Regulations (as in effect on the date of enactment of this Act)), with significant improvements compared to commercial nuclear reactors under construction as of the date of enactment of this Act, including improvements such as (A) additional inherent safety features; (B) significantly lower levelized cost of electricity; (C) lower waste yields; (D) greater fuel utilization; (E) enhanced reliability; (F) increased proliferation resistance; (G) increased thermal efficiency; or (H) ability to integrate into electric and nonelectric applications.
The staff interprets NEIMAs definition of an advanced nuclear reactor, which states that such a reactor will have significant improvements compared to commercial nuclear reactors under construction as of January 14, 2019, as excluding Generation III+ designs from the definition because the AP1000 reactors were under construction at the time of NEIMAs enactment.
Subpart A - § 53.020 Definitions 45
- Consensus code or standard o
means any technical standard (1) developed or adopted by a voluntary consensus standard body under procedures that assure that persons having interests within the scope of the standard that are affected by the provisions of the standard have reached substantial agreement on its adoption, (2) formulated in a manner that afforded an opportunity for diverse views to be considered, and (3) designated by the standards body as such a standard for the safe design, manufacture, construction, or operation of nuclear power plants.
Subpart A - § 53.020 Definitions 46
- End state o
means the set of conditions at the end of an event sequence that characterizes the impact of the sequence on the plant or resulting releases of radionuclides to the environment. In most probabilistic risk assessments, end states typically include success states (i.e., those states with negligible impact) and release categories.
- Event sequence o
means a postulated initiating event defined for a set of initial plant conditions followed by system, safety function, and operator successes or failures, and terminating in a specified end state depending on the system, safety function, and operator successes and failures (e.g., prevention of release of radioactive material or release in one of the reactor-specific release categories). An event sequence may include many unique variations of events (e.g., minimal cut sets) that are similar in terms of how they impact the performance of safety functions along the event sequence.
Subpart A - § 53.020 Definitions 47 Normal plant operation or normal operation o
means operations that are expected to occur during planned operations or shutdown of the reactor.
Licensing basis events (LBEs) mean a collection of event sequences considered in the design and licensing of the advanced nuclear plant. LBEs are unplanned events and include AOOs, unlikely event sequences, very unlikely event sequences, and DBAs.
Design basis accidents (DBAs) mean postulated event sequences that are used to set functional design criteria and performance objectives for the design of safety-related structures, systems, and components. DBAs are a type of licensing basis event and are based on the capabilities and reliabilities of safety-related structures, systems, and components needed to mitigate and prevent event sequences, respectively.
Anticipated operational occurrences (AOOs) o mean anticipated event sequences expected to occur one or more times during the life of a nuclear power plant. An event sequences with a mean frequency of 1x10-2/plant-year and greater is an AOO. AOOs take into account the expected responses of all SSCs within the plant, regardless of safety classification. AOOs are a type of licensing basis event. [Based, in part, on Appendix A to part 50.]
Subpart A - § 53.020 Definitions 48 Unlikely event sequences o
mean event sequences that have estimated frequencies below the frequency of AOOs. Unlikely event sequences are a subset of LBEs. [For example, within the licensing modernization project, this would equate to design basis events with a frequency range of between 1x10-4 and 1x10-2 per plant year with an accounting for uncertainties.]
Very unlikely event sequences o
mean event sequences that have estimated frequencies well below the frequency of events expected to occur in the life of an advanced nuclear plant. Very unlikely event sequences are a subset of LBEs. [For example, within the licensing modernization project, this would equate to beyond design basis events with a frequency range of between 5x10-7 and 1x10-4 per plant year with an accounting for uncertainties.]
The frequency ranges were incorrect in the publicly-released preliminary proposed rule language. The NRC staff have corrected the error in the definitions above and will update the definitions in a future iteration of subpart A, General Provisions.
Subpart A - § 53.020 Definitions 49
- Safety-related (SR) o means those SSCs and human actions that warrant special treatment and are relied upon to demonstrate compliance with the safety criteria in § 53.210(b).
- Non-safety related but safety significant (NSRSS) o means those SSCs and human actions that warrant special treatment and are not safety-related but are relied on to achieve defense-in-depth or perform risk-significant functions.
- Non-safety significant (NSS) o means those SSCs not warranting special treatment, are not safety-related, and are not relied on to achieve adequate defense-in-depth or to perform risk-significant functions.
Subpart A - § 53.020 Definitions 50
- Special treatment o
means those requirements, such as measures taken to satisfy functional design criteria, quality assurance, and programmatic controls, that provide assurance that certain SSCs will provide defense-in-depth or perform risk-significant functions and that provide confidence that the SSCs will perform under the service conditions and with the reliability assumed in the analysis performed in accordance with § 53.450 to provide reasonable assurance of meeting the safety criteria in § 53.210(b) and § 53.220(b).
- Defense in depth o
means inclusion of multiple independent and redundant layers of defense in the design of a facility and its operating procedures to compensate for potential human and mechanical failures so that no single layer of defense, no matter how robust, is exclusively relied upon. Defense-in-depth includes, but is not limited to, the use of access controls, physical barriers, redundant and diverse key safety functions, and emergency response measures.
Subpart A - § 53.020 Definitions 51
- Design features o
means the active and passive structures, systems, or components and inherent characteristics of those structures, systems or components that contribute to limiting the total effective dose equivalent to individual members of the public during normal operations and prevent or mitigate the consequences of unplanned events.
- Inherent characteristic means an attribute of a design feature that has such a high degree of certainty in its performance that uncertainties need not be quantified.
- Functional design criteria o
means requirements for the performance of SSCs. For safety-related SSCs, these criteria define requirements necessary to demonstrate compliance with first tier safety criteria in § 53.210(b).
For non-safety-related but safety-significant SSCs, these criteria define requirements necessary to meet the second tier safety criteria in § 53.220(b).
Subpart A - § 53.040 - § 53.120 Other Administrative Requirements 52
- Subpart A consistent with Part 50 and currently includes bracketed references to existing requirements in Parts 50, 52, etc.
- Intending to develop Part 53 with largely no pointers to Parts 50 and 52; this will require copying and pasting the Part 50 or 52 language into Part 53 instead of using pointers.
- Subpart A will include many pointers to other sections of Part 53 that will be added in future iterations.
Subpart A - Stakeholder Feedback 53 Advanced nuclear plant o
Allow broad applicability for advanced reactors under Part 53.
Design basis accident o
Clarify the relationship between DBAs and unlikely event sequences and very unlikely event sequences.
Consensus codes and standards o
Questioned use of must in definition and asked if term includes general engineering standards, such as IEEE.
Defense in depth o
Update subpart B to match the definition in subpart A because the definition excludes the clause that no single feature should be exclusively relied upon.
Safe, stable end state o
Clarify if this term requires complete shutdown or demonstration of no further inventory release.
Safety related, Non-safety related, Non-safety related but safety significant o
Clarify these terms in a way that reduces overlap.
Subpart A - General Provisions Discussion 54
MEETING BREAK Meeting to resume in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 55
56 Subpart F - Operational Objectives
Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Operational Objectives Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 57
Subpart F - § 53.700 Operational Objectives 58
- Licensee must:
o Define structures, systems, and components (SSCs) o Maintain capabilities and reliabilities of SSCs o Ensure plant personnel have adequate knowledge and skills to perform their assigned duties to support safety functions o Implement plant programs sufficient to ensure the performance of identified safety functions
Subpart F - § 53.710 Transition to Operation 59
- Prepare a transition plan from construction to operations o Demonstrate the SR and NSRSS SSCs are appropriately constructed and capable to perform o Plant personnel are appropriately licensed and trained to perform safety functions o Programs, procedures and controls are implemented to support the safety functions
Subpart F - § 53.720 Maintaining Capabilities 60
- Capabilities and reliability of SSCs, when combined with associated programmatic controls and human actions, provide reasonable assurance that the safety criteria defined in §§ 53.210(b) and 53.220(b) will be met.
- Paragraph (a) defines controls for SR SSCs (technical specifications).
- Paragraph (b) defines controls for NSRSS SSCs (reliability assurance and other special treatment).
Subpart F - § 53.720(a)
Technical Specifications (TS) 61 TS required to define conditions or limitations on SSCs to fulfill safety functions (§ 53.230) and first tier safety criteria (§ 53.210(b))
Inventories of radioactive materials Operating limits For each SSC classified as safety related Limiting Conditions for Operation Surveillance Requirements Design Attributes Administrative Controls Decommissioning First iteration does not include:
- Safety limits or associated limiting safety system settings
- Criteria for limiting conditions for operation Some stated preferences to use deterministic approaches may be better addressed within Part 50.
Subpart F - § 53.720(b)
Special Treatment of NSRSS SSCs 62 Configurations and special treatments for NSRSS SSCs ensure capabilities, availabilities, and reliabilities to satisfy second tier safety criteria (§ 53.210(b)).
Controls must:
Identify authorities and processes for configuration changes Describe means by which special treatments for each NSRSS SSC will be provided and maintained Controls for NSRSS SSCs needed to implement a performance-based approach used to gain operational flexibilities and as part of methods that include replacing the single-failure criterion with a probabilistic (reliability) approach.
Deterministic approaches with different supporting analysis, safety classification schemes, and design approaches (e.g., inclusion of the single failure criterion) may be better addressed within Part 50.
Subpart F - § 53.730 Maintenance, Repair and Inspection 63 a) Develop a program to maintain and repair SR and Safety Significant SSCs.
b) Take appropriate corrective action when NSRSS SSCs do not meet special treatment requirements or performance goals.
c) Evaluate performance and preventive maintenance activities every 24 months.
d) Conduct risk-informed assessment of the impact and scope of any maintenance activities.
Subpart F - § 53.740 Design Control 64
- Assess the potential for adverse effects on safety, security, emergency preparedness (EP), operations, or other items related to plant safety during the design process and before implementing design or operational changes.
o Physical modifications, procedural changes, operator actions, maintenance activities, system reconfigurations, access modifications or restrictions, changes to the emergency plan and security plan or their implementation.
o Establish measures for the identification and control of interfaces among plant activities.
Subpart F, Operational Objectives -
Stakeholder Feedback 65
- In general, reduce the duplication of requirements for quality assurance, testing, and review language for interactions across sections.
- Clarify safety objectives (§ 53.200), operational objectives (§ 53.700), and programs (§ 53.800) to avoid scope creep in future licensing reviews.
- Allow automated plant surveillance and testing.
Subpart F - Operational Objectives Discussion 66
67 Subpart F - Programs
Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Programs Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 68
Subpart F - § 53.800 Programs 69
- Programs must be provided for each advanced nuclear plant such that, when combined with associated design features and human actions, the plant will satisfy the first and second tier safety criteria defined in §§ 53.210 and 53.220.
Subpart F - § 53.810 Radiation Protection 70
- Implement a radiation protection program to limit occupational exposure in accordance with Part 20.
- Limit exposure to the public.
o Develop procedures and remedial actions in an Offsite Dose Calculations Manual (ODCM).
o ODCM
Define methodology used in the calculation.
Contain radioactive effluent controls and environmental monitoring activities.
Annual Radiological Environmental Operating and Radioactive Effluent Release Reports.
Subpart F - § 53.820 Emergency Preparedness 71
- Develop and implement an EP Program for operations that is commensurate with the risks posed by the licensing basis events as analyzed in accordance with § 53.450.
o Staff is developing preliminary proposed rule language for Part 53 in coordination with activities related to the Emergency Preparedness for Small Modular Reactors and Other New Technologies rulemaking.
Subpart F - § 53.830 Security Programs 72
- Develop and implement security programs:
o Information security o Physical security o Cyber security o Access authorization o Material control and accounting
Subpart F - § 53.840 Quality Assurance (QA) 73
- Develop and execute a QA program:
o Define duties and responsibilities for QA of SSCs o Written QA manual o Written procedures
Qualified personnel
Procurement
Handling, shipping and storage of materials
Testing and inspection
Corrective action
Document and configuration control
Design control
Record keeping
Auditing o Document results of QA activities
Subpart F - § 53.850 Integrity Assessment Program (IAP) 74
- Develop and implement an IAP.
- Monitor, evaluate and manage:
o Effects of aging on SR and NSRSS SSCs whose failure could affect performance of safety functions.
o Cyclic and transient loads are maintained within applicable design limits.
o Degradation related to chemical interactions, operating temperatures, irradiation, and other environmental factors to ensure the capabilities and reliabilities of SSCs satisfy the functional design criteria of §§ 53.410(b) and 53.420(b).
Subpart F - § 53.860 Fire Protection 75
- Develop and implement a fire protection plan:
o Identify responsible parties and authorities o Outline plans for fire protection, detection, suppression capability, and limitation of damage o Administrative controls, personnel requirements, and suppression activities o Means to limit damage to SR and NSRSS SSCs
- Specific features of program:
o SR and NSRSS SSCs designed to minimize effect of fires o Use noncombustible and fire-resistant materials wherever practical in facility o Appropriate capacity and capability o Design such that inadvertent operation does not impair SR SSCs
Subpart F - § 53.870 Inservice Testing (IST) and Inservice Inspection (ISI) 76
- Develop programs for ISI and IST:
o ISI and IST includes codes and standards supplemented by risk insights o Testing and frequency done to maintain reliability of SSCs o Documented procedures
- Perform baseline inspections prior to starting operations:
o Determine benchmarks o Develop acceptance criteria o Results provided to plant manager and determine need for corrective action
Subpart F - § 53.880 Criticality Safety Program 77
- The program must address the requirements in 10 CFR 70.24 for maintaining a monitoring system capable of detecting a criticality, having emergency procedures, and providing radiation protection for plant workers.
A topic for discussion is whether the alternatives to 10 CFR 70.24 provided in 10 CFR 50.68, Criticality accident requirements, are appropriate and useful in Part 53.
Subpart F - § 53.890 Facility Safety Program (FSP) 78
- Establish an FSP using a risk-informed, performance-based process to proactively identify new or revised hazards and performance issues.
- Routinely evaluate potential hazards, operating experience, human actions, and programmatic controls.
- Consider measures to mitigate or eliminate the resulting risks.
Subpart F - § 53.892 FSP Performance Criteria 79
- Take measures to protect public health and minimize danger to life or property as may be reasonably achieved when considering costs.
o Assess risk reduction measures related to radionuclide release during normal operation.
o Assess risk reduction measures for contributors to the overall cumulative risk from unplanned events.
- Certified designs/manufacturing licenses must also use change control from Subpart H.
Subpart F - § 53.894 FSP Plan 80
- FSP must use written plan and address:
o Scope of facilities covered o
How FSP will be implemented o
How personnel will be trained in FSP o
Risk-informed hazard management program o
Technology assessment program o
Internal facility safety program assessment Note that staff is looking at the possibility that some of the administrative details in the first iteration language might be addressed within guidance documents.
Subpart F - § 53.896 Review, Approval, and Retention of FSP 81
- FSP plan is part of the application
- NRC to review/approve FSP plan
- Will define staff process for reviewing FSP plan changes and amendments
Subpart F - § 53.900 Procedures and Guidelines 82
- Integrated set of procedures and guidelines to maintain normal operations and respond to unplanned events
- Plan must address:
o Plant operations o Maintenance under § 53.730 o Program requirements under this subpart (e.g., radiation protection, QA, Integrity Assessment) o Emergency operating procedures if human intervention required o Accident management guidelines
Subpart F, Programs -
Stakeholder Feedback 83
- Industry stakeholder feedback focused on regulatory burden o Industry stakeholders urged NRC to reduce net burden with Part 53 rule. Concern new subpart F provisions will increase burden, including transition to operations (§ 53.710), integrity assessment programs (§ 53.850),
criticality safety program (§ 53.880), and facility safety program (§ 53.892).
o Industry stakeholders concerned regulatory burden makes rule unattractive.
- NGO stakeholder disagreed with industry feedback and suggested NRC staff revert to traditional notice and comment rulemaking process.
Subpart F: Programs Discussion 84
85 Discussion on Previously Released Subparts and Integration of Subparts (if time allows)
Stakeholder Feedback on Previously Released Subparts 86
- Subpart B - Technology-Inclusive Safety Requirements o Some stakeholders commented that the NRC need not regulate NSS SSCs.
o A stakeholder asked the NRC to clarify how inherent characteristics could be credited for DID.
o Industry stakeholders characterized the NRCs second iteration of subpart B as less than transformational and reiterated concerns about the two-tiered safety construct.
- Subpart C - Design and Analysis Requirements o Industry stakeholders would prefer NRC adopt a graded approach to PRA.
Stakeholder Feedback on Previously Released Subparts 87
- Subpart D - Siting Requirements o Industry stakeholders expressed support for the potential to collapse the exclusion area boundary and the low population zone to the site boundary.
- Subpart E - Construction and Manufacturing Requirements o Stakeholders asked the NRC to clarify the scope and applicability of a manufacturing license (ML) as it may relate to subcontractors, transportation, the completion status of the reactor, and linkage to the combined license.
o Industry stakeholders will provide input on potential business models for ML applicants and the timeframe for these business models so that the NRC can develop appropriate and timely requirements.
Previously Released Subparts Discussion 88
Final Discussion and Questions 89
Part 53 Rulemaking Schedule Milestone Schedule Major Rulemaking Activities/Milestones Schedule Public Outreach, ACRS Interactions and Generation of Proposed Rule Package Present to April 2022 (11 months)
Submit Draft Proposed Rule Package to Commission May 2022 Publish Proposed Rule and Draft Key Guidance October 2022 Public Comment Period - 60 days November and December 2022 Public Outreach and Generation of Final Rule Package January 2023 to February 2024 (14 months)
Submit Draft Final Rule Package to Commission March 2024 Office of Management and Budget and Office of the Federal Register Processing July 2024 to September 2024 Publish Final Rule and Key Guidance October 2024 90
Acronyms and Abbreviations 91 ACRS Advisory Committee on Reactor Safeguards AEA Atomic Energy Act AOO Anticipated operational occurrence BNL Brookhaven National Laboratory CFR Code of Federal Regulations DBA Design basis accident DID Defense in depth EP Emergency preparedness FSP Facility Safety Program HFE Human factors engineering HSI Human-system interface IAP Integrity Assessment Program ISG Interim staff guidance ISI Inservice testing IST Inservice inspection LBE Licensing basis event LMP Licensing Modernization Project LWR Light water reactor MHA Maximum hypothetical accident ML Manufacturing license NEIMA Nuclear Energy Innovation and Modernization Act NGO Non-governmental organization NRC U.S. Nuclear Regulatory Commission NRR Office of Nuclear Reactor Regulation
Acronyms and Abbreviations 92 NSRSS Non-safety related but safety significant NSS Non-safety significant NWPA Nuclear Waste Policy Act of 1982 ODCM Offsite Dose Calculations Manual OL Operating license PRA Probabilistic risk assessment QA Quality assurance RES Office of Nuclear Regulatory Research SAT Systems Approach to Training SMR Small modular reactor SR Safety related SSC Structures, systems, and components STA Shift technical advisor TS Technical specifications
Background Slides 93
First Principles 94 See: SECY-18-0096, Functional Containment Performance Criteria for Non-Light-Water-Reactors, and INL/EXT-20-58717, Technology-Inclusive Determination of Mechanistic Source Terms for Offsite Dose-Related Assessments for Advanced Nuclear Reactor Facilities
Integrated Approach Consequence Based Security EP for SMRs and ONTs Functional Containment Insurance and Liability Siting near densely populated areas Environmental Reviews Licensing Modernization Project 95
Part 53 Rulemaking 96 The Part 53 Rulemaking Process*
- The process depicted in this schematic is unique to the Part 53 rulemaking and varies in some ways compared to a similar A Typical Rulemaking Process schematic available on the NRCs public website.
=
Background===
Nuclear Energy Innovation and Modernization Act (NEIMA; Public Law 115-439) signed into law in January 2019 requires the NRC to complete a rulemaking to establish a technology-inclusive, regulatory framework for optional use for commercial advanced nuclear reactors no later than December 2027 o
(1) ADVANCED NUCLEAR REACTORThe term advanced nuclear reactor means a nuclear fission or fusion reactor, including a prototype plant with significant improvements compared to commercial nuclear reactors under construction as of the date of enactment of this Act, 97