OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION May 20, 2021 MEMORANDUM TO:
Benjamin Beasley, Chief Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:
Adrian Muniz, Project Manager Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation
SUBJECT:
JOINT CNSC-U.S. NRC FIRST ROUND OF QUESTIONS TO TERRESTRIAL ENERGY INC. AND TERRESTIAL ENERGY USA, INC. - METHODOLOGY AND SELECTION OF POSTULATED INITATING EVENTS FOR THE IMSR DESIGN Under the work plan on cooperation in pre-application review activities pertinent to the Integral Molten Salt Reactor (IMSR) design, the Canadian Nuclear Safety Commission (CNSC) and U.S. Nuclear Regulatory Commission (U.S. NRC) agreed to develop and issue a common report that provides feedback on the methodology and selection of postulated initiating events (PIE) for the IMSR design. By letter dated April 27, 2021, the CNSC transmitted the joint CNSC and U.S. NRC first round of questions in support of the aforementioned report. The feedback is being derived from common information that was made available to both regulators through:
The CNSCs Phase 2 Vendor Design Review process
Terrestrial Energy USA, Inc. (TEUSA), PIE white paper (Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML20318A178)
The document containing the joint questions is in Enclosure 1 and it is Proprietary. In the CNSC letter, TEUSA was requested to confirm that this document appropriately identified all proprietary information within 10 working days of the CNSC letter. to this memo contains Proprietary information. When separated from Enclosure 1, this document is DECONTROLLED.
CONTACT: Adrian Muniz NRR/DANU 301-415-4093 Signed by Muniz Gonzalez, Adrian on 05/20/21
OFFICIAL USE ONLY - PROPRIETARY INFORMATION B.Beasley 2
OFFICIAL USE ONLY - PROPRIETARY INFORMATION TEUSA provided such confirmation recently. As a result, and as indicated in the CNSC letter, the U.S. NRC is also placing a public redacted version of the joint questions as Enclosure 2 to this memo.
Project No.: 99902076