ML21133A119

From kanterella
Jump to navigation Jump to search
0 to Updated Final Safety Analysis Report, Chapter 13, Figures
ML21133A119
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 04/29/2021
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21138A803 List: ... further results
References
Download: ML21133A119 (4)


Text

LGS UFSAR Figures 13.1-1 through 13.1-4 Deleted Figure 13.2-1 Deleted REV. 20, SEPTEMBER 2020

_J i i

. I

..J i_:***-* d

~

UNIT 1 (1)

ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY. IF, IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE NECES*

SARIL Y INCLUDED IN THE DEFINITION OF "AT THE CONTROLS" FOR THAT UNIT.

(2l NORMAL "AT THE CONTROLS" LOCATIONS DO NOT APPLY DURING ANY CONDITION DURING WHICH THE CONTROL ROOM IS NOT HABITABLE. IN THAT EVENT, THE "AT THE CONTROL" LOCATION IS THE EMERGENCY SHUTDOWN PANEL FOR THAT UNIT.

(3)

IN THE EVENT OF AN EMERGENCY AFFECTING THE SAFETY OF OPERATIONS, THE OPERATOR MAY MOMENTARILY BE ABSENT FROM THE DESIGNATED AREA TO VERIFY THE RECEIPT OF AN ANNUNCIATOR ALARM OR INITIATE CORRECTIVE ACTION. PROVIDED THE OPERATOR REMAINS WITHIN THE CONFINES OF THE CONTROL ROOM AND OBTAINS THE PERMIS*

SION OF THE CONTROL ROOM SRO AT THE TIME.

[.'

ii' iii ij~niu ::~

  • I I I 1-i

,_j LIMERICK GENERATING STATION UNITS 1ANO2 UPDATED FINAL SAFETY ANALYSIS REPORT DEFINITION OF "AT THE CONTROLS" SHEET 1 OF 2 FIGURE 13.5-1 REV. 13 09/06

UNIT2 NOTES (1)

ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY. IF, IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE NECES-SARIL Y INCLUDED IN THE DEFINITION OF,.AT THE CONTROLS" FOR THAT UNIT. OFFICE, UTILITY, OR REST FACILITIES ARE NOT INCLUDED IN THE DEFINED BOUNDARY WITH THE FOLLOWING EXCEPTION: THE UNIT 2 OPERATOR MAY OPEN THE SHIFT SUPERINTENDENT OFFICE DOOR, FOR VERBAL COMMUNICATION AS LONG AS HE REMAINS IN THE AREA CIR*

CUMSCRIBEO BY THE DOOR ANO THE DOOR IS HELO OPEN.

(2)

NORMAL "AT THE CONTROLS., LOCATIONS DO NOT APPLY DURING ANY CONDITION DURING WHICH THE CONTROL ROOM IS NOT HABITABLE. IN THAT EVENT, THE "AT THE CONTROL" LOCATION IS THE EMERGENCY SHUTDOWN PANEL FOR THAT UNIT.

13)

IN THE EVENT OF AN EMERGENCY AFFECTING THE SAFETY OF OPERATIONS, THE OPERATOR MAY MOMENTARILY BE ABSENT FROM THE DESIGNATED AREA TO VERIFY THE RECEIPT OF AN ANNUNCIATOR ALARM OR INITIATE CORRECTIVE ACTION, PROVIDED THE OPERATOR REMAINS WITHIN THE CONFINES OF THE CONTROL ROOM ANO OBTAINS THE PERMIS-SION OF THE CONTROL ROOM SRO AT THE TIME.

~ I I

I I

J...

i!*

'l* :

l;I I

I LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY.ANALYSIS REPORT DEFINITION OF

AT THE CONTROLS" SHEET 2 OF 2 FIGURE. 13.5*1 REV. 13 09{9_6_

I I

I Ii 1-1

. *-_:.?

I'_,.,.~,

I :

  • . I

':= atlU_,

I '

.,.., I. ! : I I

. ~

.!:~

I I.

. I

~

11)

ONLY CONTROL PANELS ASSOCIATED WITH THE OPERATION OF THAT UNIT OR COMMON UNIT PANELS ARE INCLUDED INSIDE THE DEFINED BOUNDARY. IF. IN THE FUTURE, PANELS ARE ADDED TO THE CONTROL ROOM, THEY ARE NECES-SARILY INCLUDED IN THE DEFINITION OF "AT THE CONTROLS" FOR THAT UNIT. OFFICE, UTILITY, OR REST FACILITIES ARE NOT INCLUDED IN THE DEFINED BOUNDARY WITH THE FOLLOWING EXCEPTION : THE SRO MAY OPEN THE SHIFT SUPERINTENDENT OR ADJACENT OFFICE INSTRUMENT LAB, ANO SHOP DOORS FOR VERBAL COMMUNICATION AS LONG AS HE REMAINS IN THE AREA CIRCUMSCRIBED BY THE DOOR ANO THE DOOR IS HELD OPEN.

-~- -

  • ~ -----*---~....,J,--.

i*

I I*

LIMERICK GENERATING STATION UNITS 1AND2 UPDATED FINAL SAFETY ANALYSIS REPORT SAO CONTROL ROOM BOUNDARIES FIGURE 13.5-2 REV. 13 09/06