Department of Energy West Valley Demonstration Project 10282 Rock Springs Road West Valley, NY 14171-9799 Ms. Marlayna Doell, Project Manager Reactor Decommissioning Branch Division of Decommissioning, Uranium Recovery, and Waste Programs Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 22644 Hazel Lane Rapid City, SD 57702
SUBJECT:
Air Dispersion Modeling Performed in Support of West Valley Demonstration Project (WVDP) Main Plant Process Building (MPPB) Demolition Preparations
REFERENCE:
Letter (384037), M. Doell to B. C. Bower, U.S. Department of Energy West Valley Demonstration Project - Acceptance of Main Plant Process Building Decommissioning and Demolition Plan, WVDP-586, Revision 4, dated May 7, 2020, (Docket No. 50-201 (POOM-032)), dated March 4, 2021
Dear Ms. Doell:
The U.S. Department of Energy West Valley Demonstration Project (DOE-WVDP) has performed air dispersion modeling to estimate emissions and associated dose estimates in support of preparations for demolition of the MPPB. In response to the U.S. Nuclear Regulatory Commission (NRC) request for information regarding such modeling (Reference), the following documents are enclosed:
- WVDP-605, Estimated Radiological Air Emission During Open-Air Demolition, Main Plant Process Building;
- WVDP-606, West Valley Demonstration Project Main Plant Process Building, Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H;
- WVDP-607, Air Dispersion Modeling for Open-Air Demolition, Main Plant Process Building.
In addition, the following modeling files that support WVDP-605 and WVDP-607 are being provided in electronic format:
CAP88 Files:
AERMOD Files:
MPPB_HC.dat WVDP MPPB 1.ami MPPB_HC.SYN WVDP MPPB 1.aml MPPB_HC.FAC WVDP MPPB 1.amz MPPB_HC.WEA MPPB_HC.GEN MPPB_HC.SUM av_12_10.wnd April 27, 2021
Ms. Marlayna Doell April 27, 2021 The March 4, 2021, NRC letter also requested updated MPPB demolition schedule information.
Uncertainty regarding COVID-19 impacts makes it somewhat difficult to forecast the start of MPPB demolition; however, schedule status information can be provided for insight. The current schedule indicates commencement of MPPB demolition at the end of September 2021. The critical path currently runs through deactivation of the Product Purification Cell-South (PPC-S).
This work has been paused due to COVID-19 related work restrictions. Assuming base planning assumptions for work efficiency and Nitrocision effectiveness, there remains at least six (6) months of effort for source term removal using Nitrocision. Each month Nitrocision work in the PPC-S remains paused, results in a month delay to the start of MPPB demolition; therefore, if work remains paused through April, the MPPB demolition start date would be anticipated to push to the end of October 2021. DOE-WVDPs contractor will be looking at opportunities to recover schedule, but currently the earliest date for initiating MPPB demolition would be sometime in early Fall 2021.
As indicted above, some MPPB decontamination/deactivation work continues in preparation for facility demolition. The building characterization information provided in WVDP-606, used to support both WVDP-605 and WVDP-607, is based on the assumption that Nitrocision will be successful in removing 80% of the source term in the PPC-S. DOE-WVDP will continue to update NRC regarding final deactivation and source term removal efforts once this work is able to resume.
As suggested in Reference 1, should NRC have questions or input regarding details provided in the attached, a meeting could be arranged to facilitate technical dialogue among the appropriate subject matter experts.
If you have any questions concerning this matter or would like to arrange a meeting for further discussion, please contact Moira N. Maloney of my staff at (716) 870-8679.
Sincerely, Bryan C. Bower, Director West Valley Demonstration Project
Enclosures:
- 1. WVDP-605, Estimated Radiological Air Emission During Open-Air Demolition, Main Plant Process Building
- 2. WVDP-606, West Valley Demonstration Project Main Plant Process Building, Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H
- 3. WVDP-607, Air Dispersion Modeling for Open-Air Demolition, Main Plant Process Building
- 4. CD containing modeling files cc:
See Page 3 BLM:384230 - 450.4
Ms. Marlayna Doell April 27, 2021 cc: T. D. Dogal, CHBWV, WV-PL17, w/o enc.
D. P. Klenk, CHBWV, AC-RS, w/o enc.
E. A. Lowes, CHBWV, AC-RS, w/o enc.
R. E. Steiner, CHBWV, AC-RS, w/o enc.
M. C. Bell, DOE-EMCBC, Office of the Director, w enc. 1-3 M. N. Maloney, DOE-WVDP, AC-DOE, w/o enc.
D. W. Sullivan, DOE-WVDP, WV-DOE, w/o enc.
A. M. Snyder, NRC, w/ enc.1-3, Amy.Snyder@nrc.gov P. J. Bembia, NYSERDA, AC-NYS, w/enc. 1-3 BLM:384230 - 450.4
Ms. Marlayna Doell April 27, 2021 WVDP-605, Estimated Radiological Air Emission During Open-Air Demolition, Main Plant Process Building
West Valley Demonstration Project Doc. ID Number WVDP-605 Revision Number 1
Revision Date 04/20/2021 ESTIMATED RADIOLOGICAL AIR EMISSION DURING OPEN-AIR DEMOLITION MAIN PLANT PROCESS BUILDING Cognizant Author:
B. C. BLUNT Cognizant Manager:
E. A. LOWES CH2M HILL BWXT West Valley, LLC 10282 Rock Springs Road West Valley, New York USA 14171-9799 WV-1816, Rev. 8 VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE
WVDP-605 Rev. 1 Page 2 of 22 WEST VALLEY DEMONSTRATION PROJECT Estimated Radiological Air Emission during Open Air Demolition Main Plant Process Building
WVDP-605 Rev. 1 Page 3 of 22 3
Introduction The Main Plant Process Building (MPPB) at the West Valley Demonstration Project (WVDP) is currently undergoing decontamination and decommissioning activities under the purview of the Department of Energys (DOE) Office of Environmental Management (EM). When the hazards in the buildings have been adequately reduced the MPPB structures will be demolished in open air.
The attached calculation documents that the West Valley Demonstration Project (WVDP) does not need to seek US Environmental Protection Agency (EPA) approval for demolition of the MPPB at the WVDP. The calculations conducted in this document fulfill requirements in 40CFR61.96 under Subpart H for Department of Energy (DOE) facilities. Section 61.96 requires that the WVDP show that air emissions from this activity be below that level which would result in a dose to the maximally exposed off-site individual (member of the public) of one percent of the 10 mrem/year rad-NESHAP standard (i.e., 0.1 mrem/year) in order to be exempt from the need to seek EPA approval for this activity. The regulation requires that this calculation be performed in accordance with Appendix D of 40CFR61 or an approved alternative.
This document has been prepared in accordance with the approved alternative methods contained in the document BC-RP-0124, Methodology for Radionuclide Source Term Calculations for Air Emissions from Demolition Activities, Rev 1, 09/10/2018, B.C. Blunt author. The EPA issued its formal (prior) approval for the use of these methods in lieu of Appendix D, on July 17, 2019. Throughout this document the approved alternative method is referred to as the Alternative Method.
Based upon use of the alternative method a total dose of 0.043 mrem/year, for all facility spaces being demolished in a single year, demonstrates that demolition of the MPPB (a multi-year project) is exempt from the need to seek EPA approval for this activity. The WVDP may make changes to this calculation based upon new or changing data. The EPA will be notified if the exemption status changes.
Discussion In order to perform open-air demolition of the MPPB without obtaining prior approval from the EPA, the estimated emissions, on an annual basis, must be less than 0.1 mrem/yr to the Maximally Exposed Offsite Individual (MEOSI). To determine the dose to the MEOSI during open-air demolition two key factors must be considered:
- 1. The Material at Risk (MAR)
The first of these key factors, the MAR, is developed using the Characterization Database as a starting point. The second factor is based on the type of material being processed. Both factors are addressed in WVDP-606, Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H, which presents an environmental inventory or MAR for each demolition method. The MAR as developed in WVDP-606 is reproduced here as Table 1.
WVDP-605 Rev. 1 Page 4 of 22 4
Table 1: Environmental MAR Radionuclide Hydraulic Hammer Technique Mechanical Shear Technique Off-Gas Cell (OGC)
Corner Concrete Saw Technique Hot Cutting Technique Total Cs-137 (Ci) 2.48E+00 2.24E-01 1.74E+01 2.29E-04 2.01E+01 Sr-90 (Ci) 3.72E+00 1.84E-01 4.67E+01 6.14E-04 5.06E+01 Cm-243 (Ci) 2.55E-04 1.31E-05 2.09E-03 2.75E-08 2.36E-03 Cm-244 (Ci) 5.62E-03 5.11E-04 4.67E-02 6.14E-07 5.28E-02 Np-237 (Ci) 1.59E-03 1.32E-03 1.99E-04 2.61E-09 3.11E-03 Am-241 (Ci) 1.94E+00 3.46E-02 2.51E+00 3.30E-05 4.48E+00 Pu-238 (Ci) 6.10E-01 1.03E-02 8.76E-01 1.15E-05 1.50E+00 Pu-239 (Ci) 4.97E-01 7.52E-03 6.46E-01 8.49E-06 1.15E+00 Pu-240 (Ci) 3.79E-01 5.48E-03 4.89E-01 6.43E-06 8.74E-01 Pu-241 (Ci) 5.99E+00 9.61E-02 7.63E+00 1.00E-04 1.37E+01 U-232 (Ci) 1.89E-02 3.51E-04 6.15E-02 8.08E-07 8.08E-02 U-233 (Ci) 1.24E-02 9.59E-05 2.40E-02 3.16E-07 3.65E-02 U-234 (Ci) 5.92E-03 3.78E-05 1.14E-02 1.50E-07 1.74E-02 U-235 (Ci) 5.01E-04 1.01E-05 8.00E-05 1.05E-09 5.91E-04 U-238 (Ci) 5.86E-03 9.47E-06 8.95E-04 1.18E-08 6.77E-03 I-129 (Ci) 2.38E-06 2.15E-07 1.67E-05 2.20E-10 1.93E-05 Tc-99 (Ci) 1.13E-03 1.03E-04 7.98E-03 1.05E-07 9.21E-03 Ba-137m (Ci) 2.48E+00 2.24E-01 1.74E+01 2.29E-04 2.01E+01 Y-90 (Ci) 3.72E+00 1.84E-01 4.67E+01 6.14E-04 5.06E+01 As shown in Table 1 there are four demolition methods being used for demolition of the MPPB, namely Hydraulic Hammer, Mechanical Shears, Concrete Saw, and Hot Cutting. Once the building or portions of the building are demolished, the debris or rubble is often moved to a processing area where the debris or rubble is size reduced and sorted. In the case of MPPB demolition, the debris will be loaded into containers as close as possible to the point of generation. Finally, the sorted debris or rubble is loaded into containers that are sealed.
Misting, watering, and fixatives are used throughout the demolition and load-out processes to minimize airborne contamination spread.
Based on the Alternative Method, the emission factors presented in Table 2 are applicable to MPPB open-air demolition.
WVDP-605 Rev. 1 Page 5 of 22 5
Table 2: Emission Factors Method Emission Factor Shearing 5.0E-05 Hydraulic Hammer 1.0E-05 Concrete Saw Used EPA Appendix D method (40 CFR 61). Saw has a width of 0.59 inches. Assume a 10% addition to the width for a kerf of 0.65 inches. Cuts are typically made to produce a 3-foot by 8-foot surface area block. For the cuts, a physical state factor of 1.0E-03 is used and for the solid blocks the physical state factor is set to 1.0E-06.
The combined concrete saw emission factor is 9.73E-06 for the Off-Gas Cell (OGC) Corner. See below for details.
Hot Cutting Emission Factors:
Beta: 0.7 Alpha: 0.07 See WVDP-579, Vitrification Facility Air Emissions during Open Air Demolition, Measured vs. Predicted, for details regarding the determination of these two emission factors for hot cutting.
Rubble Pile Emissions a)
(0.0016) 2.2
1.3 2
1.4 If a wind speed of 6.7 m/s and moisture content of 2% are assumed, the rubble pile emissions factor is 6.81E-06.
See below for details.
Load Out Emissions 2.9E-05 a) Wind Speed units are m/s Moisture content units are %
Note: Above Emission Factor for Rubble Pile is in units of mCi released/Ci processed. All others in units of Ci released/Ci processed.
WVDP-605 Rev. 1 Page 6 of 22 6
General Assumptions The following assumptions are used throughout the development of the exemption calculation1, and must be used during the open-air demolition process for the MPPB.
- 1. Moisture content of the pile is conservatively assumed to be 2%. During the validation study the moisture content of the pile was not physically measured, however it was assumed to be 2% for piles containing mostly metal, while a value of 9% was used for concrete rubble piles.
- 2. Wind speed is conservatively assumed to be 6.7 m/s (15 mph). The average wind speed from 2014 through 2018 was 2.4 m/s and 99% of the measured wind speeds are less than or equal to 6.7 m/s.
- 3. The width of the kerf is assumed to be 0.65 inch for the concrete saw. The saw blade is 0.59 inches wide and an additional 10% is added as a conservative factor.
- 4. Cutting with the concrete saw will require several passes. The saw will be set to a designated depth (not yet finalized) and an initial pass made. The saw depth will be increased, and the saw repositioned to make the initial cut deeper. The number of passes is not yet known. However, the calculation assumes cutting all the way through the wall. The number of passes will not change the total material released, just the time it takes to complete the cuts.
Emission Calculations Most of the MPPB structure can be demolished using either hydraulic hammering or mechanical shearing method, however one wall will be processed using a concrete saw attached to an excavator and a metal shield wall in the Chemical Process Cell (CPC) will require hot cutting. Note that minor hot cutting operations may be necessary for maintenance purposes during the demolition process; for instance, to free rebar or other metal that may become lodged within the demolition equipment. Such material is not expected to have any significant levels of contamination and thus emissions are bounded by conservative inventory assumptions for the metal shield wall, as discussed in the hot cutting portion of this section. The rubble produced by the demolition will be moved from the demolition area to a processing area where the rubble will be sorted. Finally, the sorted rubble will be loaded into containers, sealed and shipped to final storage.
The source term (estimate emissions) can be found with
= x EF Equation 1 where: ST
= Source Term
= the total quantity of material released to the atmosphere during the process MAR = Material-At-Risk
= the total quantity of radionuclide available to be acted on by a given physical stress - curies (Ci) of activity (given in Table 1).
EF
= Emission factor = relates the quantity of a pollutant released to the atmosphere with an activity associated with the release of that pollutant, in this case radionuclide (given in Table 2) 1 WVDP-606, Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H.
WVDP-605 Rev. 1 Page 7 of 22 7
Hydraulic Hammer For a hammering operation with water misting, the source term for that part of the demolition operation is found with Equation 1. The following example is presented for the Am-241 hydraulic hammer inventory given in Table 1. The EF for the hydraulic hammer technique is 1.0E-05 (see Table 2).
= x EF
= 1.94 x 1.00E-05
= 1.9405 The results of this calculation for each radionuclide in the hydraulic hammer inventory are presented in Table 3.
Table 3: Hydraulic Hammer Emissions Radionuclide Hydraulic Hammer MAR (Ci)
Hydraulic Hammer Emissions (Ci/yr)
Cs-137 2.48E+00 2.48E-05 Sr-90 3.72E+00 3.72E-05 Cm-243 2.55E-04 2.55E-09 Cm-244 5.62E-03 5.62E-08 Np-237 1.59E-03 1.59E-08 Am-241 1.94E+00 1.94E-05 Pu-238 6.10E-01 6.10E-06 Pu-239 4.97E-01 4.97E-06 Pu-240 3.79E-01 3.79E-06 Pu-241 5.99E+00 5.99E-05 U-232 1.89E-02 1.89E-07 U-233 1.24E-02 1.24E-07 U-234 5.92E-03 5.92E-08 U-235 5.01E-04 5.01E-09 U-238 5.86E-03 5.86E-08 I-129 2.38E-06 2.38E-11 Tc-99 1.13E-03 1.13E-08 Ba-137m 2.48E+00 2.48E-05 Y-90 3.72E+00 3.72E-05
WVDP-605 Rev. 1 Page 8 of 22 8
Mechanical Shear For a mechanical shearing operation with water misting, the source term for that part of the demolition operation is found with Equation 1. The following example is presented for the Am-241 mechanical shear inventory given in Table 1. The EF for the mechanical shear technique is 5.0E-05 (see Table 2).
= x EF
= 3.46E-02 x 5.00E-05
= 1.73E-06 The results of this calculation for each radionuclide in the mechanical shear inventory are presented in Table 4.
Table 4: Mechanical Shear Emissions Radionuclide Mechanical Shear MAR (Ci)
Mechanical Shear Emissions (Ci/yr)
Cs-137 2.24E-01 1.12E-05 Sr-90 1.84E-01 9.21E-06 Cm-243 1.31E-05 6.55E-10 Cm-244 5.11E-04 2.56E-08 Np-237 1.32E-03 6.60E-08 Am-241 3.46E-02 1.73E-06 Pu-238 1.03E-02 5.15E-07 Pu-239 7.52E-03 3.76E-07 Pu-240 5.48E-03 2.74E-07 Pu-241 9.61E-02 4.81E-06 U-232 3.51E-04 1.75E-08 U-233 9.59E-05 4.80E-09 U-234 3.78E-05 1.89E-09 U-235 1.01E-05 5.06E-10 U-238 9.47E-06 4.73E-10 I-129 2.15E-07 1.07E-11 Tc-99 1.03E-04 5.13E-09 Ba-137m 2.24E-01 1.12E-05 Y-90 1.84E-01 9.21E-06
WVDP-605 Rev. 1 Page 9 of 22 9
Concrete Saw For a concrete saw operation with water misting, the source term for that part of the demolition operation is found with the Appendix D method from 40 CFR 61. The concrete saw will be used to remove a contaminated section of wall in the Off-Gas Cell (OGC). The wall section will be cut into sections that will have a surface area of approximately 3 feet by 8 feet. Each section will be lifted from the room and placed directly in a shipping container. One vertical surface of the column is at a construction joint and will not require sawing on that side.
The other vertical surface will require sawing. A sketch of the wall and the planned cuts is provided in Figure 1.
Off-Cell Cell corner emission factor Figure 1: Off-Gas Cell Contaminated Wall The face of the wall is contaminated and will be cut with a concrete saw. The 40 CFR 61 Appendix D method can be used to develop a combined emission factor for this demolition. Once the wall is cut, the blocks will be removed and placed in waste containers with no further demolition methods. For the areas being cut, the Appendix D particulate solid physical state factor of 1.0E-03 is applied and for the solid uncut area the Appendix D solid physical state of 1.0E-06 is applied.
() = (3 )(5 ) = 15
() = (15)12
= 180,
WVDP-605 Rev. 1 Page 10 of 22 10 The width of the kerf is assumed to be 0.65 inch (see general assumption section), and there are 5 cuts planned.
= (180 )(0.65 ) = 117.2 and
= (3)(31)144.
. = 13,392.2 A combined emission factor is then found as the ratio of the contamination that will be a particulate solid time 1.0E-03 plus the ratio of the contamination that will be a solid, times 1.0E-06.
= 117 2 13,392 2(1.003)+ 13,392 117 2 13,392 2 (1.006)
= 9.7306 The following example is presented for the Am-241 OGC Corner concrete saw inventory given in Table 1.
= x EF
= 2.51 x 9.73E-06
= 2.44E-05 The results of these calculations for each radionuclide in the concrete saw inventory are presented in Table 5.
WVDP-605 Rev. 1 Page 11 of 22 11 Table 5: Concrete Saw Emissions Radionuclide OGC Concrete Saw MAR (Ci)
OGC Concrete Saw Emissions (Ci/yr)
Cs-137 1.74E+01 1.69E-04 Sr-90 4.67E+01 4.54E-04 Cm-243 2.09E-03 2.03E-08 Cm-244 4.67E-02 4.54E-07 Np-237 1.99E-04 1.93E-09 Am-241 2.51E+00 2.44E-05 Pu-238 8.76E-01 8.52E-06 Pu-239 6.46E-01 6.29E-06 Pu-240 4.89E-01 4.76E-06 Pu-241 7.63E+00 7.42E-05 U-232 6.15E-02 5.98E-07 U-233 2.40E-02 2.34E-07 U-234 1.14E-02 1.11E-07 U-235 8.00E-05 7.78E-10 U-238 8.95E-04 8.71E-09 I-129 1.67E-05 1.63E-10 Tc-99 7.98E-03 7.76E-08 Ba-137m 1.74E+01 1.69E-04 Y-90 4.67E+01 4.54E-04
WVDP-605 Rev. 1 Page 12 of 22 12 Hot Cutting For a hot cutting operation, the source term is found with Equation 1 where the EF applied is based on the type of radionuclide involved. As detailed in WVDP-579, Vitrification Facility Air Emissions during Open Air Demolition, Measured vs. Predicted, an EF of 0.07 is applied to the alpha emitters, and an EF of 0.7 is applied to beta emitters (see Table 2). The following example is presented for the Am-241 hot cutting inventory given in Table 1
= x EF
= 3.30E-05 x 0.07
= 2.31E-06 The results of this calculation for each radionuclide in the hot cutting inventory are presented in Table 6. Note that the hot cutting inventory presented in Table 6 conservatively assumes no decontamination is performed of the contaminated metal shield wall in the CPC.
Table 6: Hot Cutting Emissions Radionuclide Hot Cutting MAR (Ci)
Emission Factor Hot Cutting Emissions (Ci/yr)
Cs-137 2.29E-04 0.7 1.60E-04 Sr-90 6.14E-04 0.7 4.30E-04 Cm-243 2.75E-08 0.07 1.92E-09 Cm-244 6.14E-07 0.07 4.30E-08 Np-237 2.61E-09 0.07 1.83E-10 Am-241 3.30E-05 0.07 2.31E-06 Pu-238 1.15E-05 0.07 8.06E-07 Pu-239 8.49E-06 0.07 5.95E-07 Pu-240 6.43E-06 0.07 4.50E-07 Pu-241 1.00E-04 0.7 7.02E-05 U-232 8.08E-07 0.07 5.66E-08 U-233 3.16E-07 0.07 2.21E-08 U-234 1.50E-07 0.07 1.05E-08 U-235 1.05E-09 0.07 7.36E-11 U-238 1.18E-08 0.07 8.24E-10 I-129 2.20E-10 0.7 1.54E-10 Tc-99 1.05E-07 0.7 7.34E-08 Ba-137m 2.29E-04 0.7 1.60E-04 Y-90 6.14E-04 0.7 4.30E-04
WVDP-605 Rev. 1 Page 13 of 22 13 Rubble Pile The rubble pile will contain, at some point in the demolition, the entire inventory in Table 1 for hydraulic hammering and mechanical shearing. The inventory associated with the OGC wall section to be processed with a concrete saw, as well as the metal shield wall in the CPC to be sized reduced using hot cutting techniques, will be placed directly in shipping containers and will not be part of the pile inventory. The rubble inventory along with the resulting emissions based on the following example calculation is presented as Table 7.
Table 7: Rubble Pile Emissions Radionuclide Rubble Pile MAR (Ci)
Rubble Pile Emissions (Ci/yr)
Cs-137 2.70E+00 1.84E-05 Sr-90 3.91E+00 2.66E-05 Cm-243 2.68E-04 1.82E-09 Cm-244 6.13E-03 4.17E-08 Np-237 2.91E-03 1.98E-08 Am-241 1.97E+00 1.34E-05 Pu-238 6.20E-01 4.22E-06 Pu-239 5.05E-01 3.44E-06 Pu-240 3.85E-01 2.62E-06 Pu-241 6.09E+00 4.14E-05 U-232 1.93E-02 1.31E-07 U-233 1.25E-02 8.50E-08 U-234 5.96E-03 4.06E-08 U-235 5.11E-04 3.48E-09 U-238 5.87E-03 4.00E-08 I-129 2.59E-06 1.76E-11 Tc-99 1.24E-03 8.42E-09 Ba-137m 2.70E+00 1.84E-05 Y-90 3.91E+00 2.66E-05 For a rubble pile operation with water misting, the source term for that part of the demolition operation is found with Equation 1. The EF for the rubble pile per Table 2 is
= (0.0016) 2.2
1.3 2
1.4.
WVDP-605 Rev. 1 Page 14 of 22 14 As given in the Assumption Section, the wind speed is set at 6.7 m/s (15 mph), and the moisture content is set to 2%. Upon substitution the EF becomes
= (0.0016) 6.7 2.2
1.3 2 2
1.4
= 6.806E 03 or
= 6.806E 06 The following example is presented for the Am-241 rubble pile inventory given in Table 1.
= x EF
= 1.97 x 6.806E-06
= 1.34E-05 The results of these calculations for each radionuclide in the rubble pile inventory are presented in Table 7.
Load Out Operation The load out operation will be conducted on the rubble pile. The rubble pile will contain, at some point in the demolition, the entire inventory in Table 1 for hydraulic hammering and mechanical shearing. The inventory associated with the OGC wall section to be processed with concrete saw, as well as the metal shield wall in the CPC to be size reduced using hot cutting techniques, will be placed directly in shipping containers and will not be part of the pile inventory. The load out operation inventory along with the resulting emissions based on the following example calculation is presented as Table 8.
WVDP-605 Rev. 1 Page 15 of 22 15 Table 8: Load Out Emissions Radionuclide Load Out MAR (Ci)
Load Out Emissions (Ci/yr)
Cs-137 2.70E+00 7.83E-05 Sr-90 3.91E+00 1.13E-04 Cm-243 2.68E-04 7.77E-09 Cm-244 6.13E-03 1.78E-07 Np-237 2.91E-03 8.43E-08 Am-241 1.97E+00 5.71E-05 Pu-238 6.20E-01 1.80E-05 Pu-239 5.05E-01 1.46E-05 Pu-240 3.85E-01 1.12E-05 Pu-241 6.09E+00 1.76E-04 U-232 1.93E-02 5.59E-07 U-233 1.25E-02 3.62E-07 U-234 5.96E-03 1.73E-07 U-235 5.11E-04 1.48E-08 U-238 5.87E-03 1.70E-07 I-129 2.59E-06 7.52E-11 Tc-99 1.24E-03 3.59E-08 Ba-137m 2.70E+00 7.83E-05 Y-90 3.91E+00 1.13E-04 For a load out operation the source term for that part of the demolition operation is found with Equation 1. The EF for the rubble pile per Table 2 is 2.9E-05.
The following example is presented for the Am-241 load out inventory given in Table 8.
= x EF
= 1.97 x 2.90E-05
= 5.71E-05 Ci The results of these calculations for each radionuclide in the rubble pile inventory are presented in Table 8.
WVDP-605 Rev. 1 Page 16 of 22 16 Emissions Summary The total emission (sum of all operations) from the planned open-air demolition of the MPPB are presented in Table 9.
Table 9: Open-air Demolition Emissions for MPPB Radionuclide Hydraulic Hammer Emissions (Ci/yr)
Mechanical Shear Emissions (Ci/yr)
Total Concrete Saw Emissions (Ci/yr)
Hot Cutting Emissions (Ci/yr)
Rubble Pile Emissions (Ci/yr)
Load Out Emissions (Ci/yr)
Total Open-Air Emissions (Ci/yr)
Cs-137 2.48E-05 1.12E-05 1.69E-04 1.60E-04 1.84E-05 7.83E-05 4.62E-04 Sr-90 3.72E-05 9.21E-06 4.54E-04 4.30E-04 2.66E-05 1.13E-04 1.07E-03 Cm-243 2.55E-09 6.55E-10 2.03E-08 1.92E-09 1.82E-09 7.77E-09 3.51E-08 Cm-244 5.62E-08 2.56E-08 4.54E-07 4.30E-08 4.17E-08 1.78E-07 7.98E-07 Np-237 1.59E-08 6.60E-08 1.93E-09 1.83E-10 1.98E-08 8.43E-08 1.88E-07 Am-241 1.94E-05 1.73E-06 2.44E-05 2.31E-06 1.34E-05 5.71E-05 1.18E-04 Pu-238 6.10E-06 5.15E-07 8.52E-06 8.06E-07 4.22E-06 1.80E-05 3.82E-05 Pu-239 4.97E-06 3.76E-07 6.29E-06 5.95E-07 3.44E-06 1.46E-05 3.03E-05 Pu-240 3.79E-06 2.74E-07 4.76E-06 4.50E-07 2.62E-06 1.12E-05 2.31E-05 Pu-241 5.99E-05 4.81E-06 7.42E-05 7.02E-05 4.14E-05 1.76E-04 4.27E-04 U-232 1.89E-07 1.75E-08 5.98E-07 5.66E-08 1.31E-07 5.59E-07 1.55E-06 U-233 1.24E-07 4.80E-09 2.34E-07 2.21E-08 8.50E-08 3.62E-07 8.32E-07 U-234 5.92E-08 1.89E-09 1.11E-07 1.05E-08 4.06E-08 1.73E-07 3.96E-07 U-235 5.01E-09 5.06E-10 7.78E-10 7.36E-11 3.48E-09 1.48E-08 2.46E-08 U-238 5.86E-08 4.73E-10 8.71E-09 8.24E-10 4.00E-08 1.70E-07 2.79E-07 I-129 2.38E-11 1.07E-11 1.63E-10 1.54E-10 1.76E-11 7.52E-11 4.44E-10 Tc-99 1.13E-08 5.13E-09 7.76E-08 7.34E-08 8.42E-09 3.59E-08 2.12E-07 Ba-137m 2.48E-05 1.12E-05 1.69E-04 1.60E-04 1.84E-05 7.83E-05 4.62E-04 Y-90 3.72E-05 9.21E-06 4.54E-04 4.30E-04 2.66E-05 1.13E-04 1.07E-03
WVDP-605 Rev. 1 Page 17 of 22 17 Dose Calculation The Total Open-Air emissions presented in Table 9 was modelled with CAP-88 PC Version 42. The modelled dose is 0.043 mrem/yr. A copy of the data file and the Synopsis report are presented in Appendix A. For this model run the default values for the Chemical Form, Clearance Type, and Particle size were used.
Dose conversion factors (DCF) were produced with CAP-88 PC version 4. The dose conversion factors assume ground level releases, which is conservative for MPPB open-air demo. The application of the DCFs to the releases presented in Table 9, when summed provide the total projected (prospective) dose for MPPB open-air demolition. The DCFs and the total open-air emissions in units of Ci/yr and mrem/yr are presented in Table 10.
Based upon use of the alternative method a total dose of 0.043 mrem/year, for all facility spaces being demolished in a single year, demonstrates that demolition of the MPPB (a multi-year project) is exempt from the need to seek EPA approval for this activity.
Table 10: Dose Calculation for Open-air Demolition of the MPPB Radionuclide Source Term (ST)
Total Open-Air Emissions (Ci/yr)
CAP-88 PC (Version 4)
Ground Level Dose Conversion Factors (mrem/Ci)
Total Open-Air Dose (mrem/yr)
Contribution for each Isotope
(%)
Cs-137 4.62E-04 11.9 5.50E-03 12.732%
Sr-90 1.07E-03 8.21 8.78E-03 20.328%
Cm-243 3.51E-08 92.8 3.25E-06 0.008%
Cm-244 7.98E-07 76.5 6.11E-05 0.141%
Np-237 1.88E-07 67.7 1.27E-05 0.029%
Am-241 1.18E-04 123 1.46E-02 33.683%
Pu-238 3.82E-05 136 5.19E-03 12.010%
Pu-239 3.03E-05 148 4.48E-03 10.378%
Pu-240 2.31E-05 148 3.41E-03 7.899%
Pu-241 4.27E-04 2.7 1.15E-03 2.668%
U-232 1.55E-06 25.6 3.97E-05 0.092%
U-233 8.32E-07 9.1 7.57E-06 0.018%
U-234 3.96E-07 8.9 3.53E-06 0.008%
U-235 2.46E-08 11.7 2.88E-07 0.001%
U-238 2.79E-07 7.42 2.07E-06 0.005%
I-129 4.44E-10 10.1 4.48E-09 0.00001%
Tc-99 2.12E-07 1.67 3.54E-07 0.001%
Ba-137m 4.62E-04 Note (a) 0.00E+00 Y-90 1.07E-03 Note (a) 0.00E+00 Total =
0.043 100%
Note (a): Both Ba-137m and Y-90 are in secular equilibrium with a parent isotope. The parents DCF includes the dose contribution from these two radionuclides 2 Version 4.0 of CAP-88 PC is an approved version of the code and is the version that has been used for all recent submittals to EPA from the WVDP.
WVDP-605 Rev. 1 Page 18 of 22 18 Appendix A CAP-88 Version 4 Synopsis File
WVDP-605 Rev. 1 Page 19 of 22 19 C A P 8 8 - P C Version 4.0 Clean Air Act Assessment Package - 1988 S Y N O P S I S R E P O R T Non-Radon Individual Assessment Mon Dec 14 17:15:00 2020 Facility: WVDP Address: 10282 Rock Springs Road City: West Valley State: NY Zip: 14171-97 Source Category: Point Source Type: Area Emission Year: 2020 DOSE Age Group: Adult Comments: MPPB Demo Ground level Area Individual Committed Effective Dose Equivalent (mrem) 4.32E-02 At This Location: 1900 Meters North Northwest Dataset Name: MPPB_HC.
Dataset Date: Dec 14, 2020 05:14 PM Wind File: \\\\Mac\\Home\\Desktop\\MPPB CAP88\\av_12_10.wnd
WVDP-605 Rev. 1 Page 20 of 22 20 Mon Dec 14 17:15:00 2020 SYNOPSIS Page 1 MAXIMALLY EXPOSED INDIVIDUAL Location Of The Individual: 1900 Meters North Northwest Lifetime Fatal Cancer Risk: 4.43E-09 ORGAN DOSE EQUIVALENT
SUMMARY
(RN-222 Working Level Calculations Excluded)
Dose Equivalent Organ (mrem)
Adrenal 7.24E-03 UB_Wall 7.75E-03 Bone_Sur 1.17E+00 Brain 7.06E-03 Breasts 7.39E-03 St_Wall 7.40E-03 SI_Wall 7.48E-03 ULI_Wall 8.87E-03 LLI_Wall 1.36E-02 Kidneys 1.06E-02 Liver 1.37E-01 Muscle 7.68E-03 Ovaries 2.33E-02 Pancreas 7.22E-03 R_Marrow 9.38E-02 Skin 1.63E-01 Spleen 7.37E-03 Testes 2.36E-02 Thymus 7.28E-03 Thyroid 7.63E-03 GB_Wall 7.23E-03 Ht_Wall 7.36E-03 Uterus 7.39E-03 ET_Reg 1.03E-02 Lung_66 2.43E-02 Effectiv 4.32E-02 RADIONUCLIDE EMISSIONS DURING THE YEAR 2020 Source
- 1 TOTAL Nuclide Type Size Ci/y Ci/y Am-241 M 1.000 1.2E-04 1.2E-04 Cm-243 M 1.000 3.5E-08 3.5E-08 Cm-244 M 1.000 8.0E-07 8.0E-07 Cs-137 F 1.000 4.6E-04 4.6E-04
WVDP-605 Rev. 1 Page 21 of 22 21 Ba-137m B 0.000 4.6E-04 4.6E-04 I-129 F 1.000 4.4E-10 4.4E-10 Np-237 M 1.000 1.9E-07 1.9E-07 Pu-238 M 1.000 3.8E-05 3.8E-05 Pu-239 M 1.000 3.0E-05 3.0E-05 Pu-240 M 1.000 2.3E-05 2.3E-05 Pu-241 M 1.000 4.3E-04 4.3E-04 Sr-90 M 1.000 1.1E-03 1.1E-03 Y-90 M 1.000 1.1E-03 1.1E-03 Tc-99 M 1.000 2.1E-07 2.1E-07 U-232 M 1.000 1.5E-06 1.5E-06 U-233 M 1.000 8.3E-07 8.3E-07 U-234 M 1.000 4.0E-07 4.0E-07 U-235 M 1.000 2.5E-08 2.5E-08 U-238 M 1.000 2.8E-07 2.8E-07 SITE INFORMATION Temperature: 8.600 degrees C Precipitation: 108.000 cm/y Humidity: 8.000 g/cu m Mixing Height: 1000.0 m User specified location of max exposed individual.
(ILOC, JLOC): NNW, 1900 meters
WVDP-605 Rev. 1 Page 22 of 22 22 Mon Dec 14 17:15:00 2020 SYNOPSIS Page 2 SOURCE INFORMATION Source Number: 1 Source Height (m): 0.00 Area (sq m): 1000.00 Plume Rise Pasquill Cat: A B C D E F G Fixed (m): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 (Fixed Rise)
AGRICULTURAL DATA Vegetable Milk Meat Fraction Home Produced: 0.7000 0.4000 0.4400 Fraction From Assessment Area: 0.3000 0.6000 0.5600 Fraction Imported: 0.0000 0.0000 0.0000 Food Arrays were not generated for this run.
Default Values used.
DISTANCES (M) USED FOR MAXIMUM INDIVIDUAL ASSESSMENT 1200 1400 1800 1900 2000 2100 2200 2400 2600 2800 2900 3300
WVDP-605 Rev. 1 WV-1807, Rev. 10 (DCIP-101) i WVDP RECORD OF REVISION Revision On Rev. No.
Description of Changes Page(s)
Dated 0
Original Issue; based upon BC-RP-0127, Rev. 3, All 02/24/2021 authored by Brent Blunt under subcontract to CHBWV.
This document affects the Regulatory Strategy and Facility Disposition Departments directly and all WVDP departments indirectly.
1 General Revision.
All 04/20/2021 Removed references to BC-RP-0127 and changed 2, 3, 6 prior reference to BC-RP-0118 to new document number WVDP-606, to avoid potential confusion.
This document affects the Regulatory Strategy and Facility Disposition Departments directly and all WVDP departments indirectly.
Ms. Marlayna Doell April 27, 2021 WVDP-606, West Valley Demonstration Project Main Plant Process Building, Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H
West Valley Demonstration Project Doc. ID Number WVDP-606 Revision Number 1
Revision Date 04/20/2021 WEST VALLEY DEMONSTRATION PROJECT MAIN PLANT PROCESS BUILDING MAIN PLANT PROCESS BUILDING RADIONUCLIDE INVENTORY FOR 40 CFR 61 SUBPART H Cognizant Author:
B. C. Blunt Cognizant Manager:
E. A. Lowes CH2M HILL BWXT West Valley, LLC 10282 Rock Springs Road West Valley, New York USA 14171-9799 WV-1816, Rev. 8 VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE
WVDP-606 Rev. 1 Page 2 of 76 WEST VALLEY DEMONSTRATION PROJECT MAIN PLANT PROCESS BUILDING Main Plant Process Building Radionuclide Inventory For 40 CFR 61 Subpart H
WVDP-606 Rev. 1 Page 3 of 76 Introduction The Main Plant Process Building (MPPB) at the West Valley Demonstration Project (WVDP) is currently undergoing decontamination and decommissioning activities under the purview of the Department of Energys (DOE) Office of Environmental Management (EM). When the hazards in the buildings have been adequately reduced, the MPPB structures will be demolished in open air.
This calculation estimates the radionuclide inventory remaining in the facilities at the time Open Air demolition will begin as it relates to the 40 CFR Part 61, Subpart H - National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities.
Inventory Discussion The inventory or material at risk (MAR) developed in this document will provide the input for estimation of emissions during open air demolition using the methods presented in Methodologies for Radionuclide Source Term Calculations for Air Emissions from Demolition Activities, Rev 1, hereafter referred to as the Alternative Method (see Appendix F of WVDP-579). The Alternative Method was approved by Region 2 of the U.S. Environmental Protection Agency (EPA) on July 17, 2019.
The WVDP maintains a Characterization Database, which includes the MPPB radiological contamination inventory. This information is contained in a raw data table that includes the data as measured in the field and laboratory. This table has been used to develop the MAR presented in this document. The raw data contained in this table was used to select and implement decontamination and inventory reduction methods conducted prior to entering the demolition phase of the project. For example, the raw data table contains the radionuclide contamination levels in tanks and pipes that have been foamed; effectively sealing the contamination from release. The tanks will be removed as sealed units during demolition. Reduction or elimination of the MAR contained in the raw data table has been performed in this document when appropriate based on the decontamination and inventory reduction methods employed. Such MAR reductions are discussed in more detail in later sections of this document.
The inventory or MAR developed in this document is based on the Characterization Database as it existed June 20, 2020, with the exception of including two additional nuclides1 (I-129 and Tc-99), which have been estimated from other radionuclides reported in the Characterization Database. These additional nuclides have been included because they are considered important isotopes in WVDP Radioisotope Inventory Reports (RIRs) and contribute to the potential dose through air, water and food pathways. I-129, specifically, was determined to be a primary contributor to off-site airborne dose during high-level waste vitrification operations.
WVDP-606 Rev. 1 Page 4 of 76 Assumptions
- 1. Contamination is evenly distributed on surfaces
- 2. The only radionuclides not included in the Characterization Database that are of environmental concern are I-129 and Tc-991.
- 3. Ba-137m is in secular equilibrium with Cs-137.
- 5. Nitrocision2 will reduce the inventory of PPC-S walls and ceilings by at least 80%.
- 6. Pipes that are greater than or equal to 1-inch in diameter and are less than or equal to 60 inches in length are embedded in a wall and have been foamed filled. Assume that 10% of these pipes are damaged enough to release radionuclides.3 Unless note elsewhere in this document, all other pipes are assumed to be removed with a mechanical shear.
Demolition Methods 4 When demolition of the MPPB is undertaken, the physical demolition can involve equipment such as mechanical shears, saws, hydraulic hammers, and other means that are appropriate for the type of structure. In general, the following assumptions have been made as to the use of various demolition methods. See Appendix A for a listing of Environmental MAR grouped by the proposed demolition method to be applied to each structure in the MPPB.
Hydraulic Hammering: This method has been assumed for all walls and structures.
Mechanical Shearing: This method has been assumed for all pipes that are not embedded in concrete walls.
Concrete Saw (40CFR61 Appendix D methodology): This method is to be applied to the north wall corner in the Off-Gas Cell (OGC) and the resulting source term has been included in the Environmental MAR. As discussed with EPA, concrete saw cutting performed during deactivation activities is not included in this analysis.
1 The Characterization Database does not include these two isotopes because the radionuclides of concern in that database are from lab analysis done for waste characterizations. These two isotopes, although of concern in environmental media, are not routinely analyzed for in waste characterization protocols. These isotopes were added to the Vitrification Facility demolition MAR for Environmental Protection Agency submittals. To be consistent they have been added to the MPPB MAR in Appendix A of this document and are included in the NESHAP evaluations and other EPA submittals.
2 After completion of the Nitrocision process, the wall and ceilings will be reevaluated. If the 80% reduction is not achieved the MAR and associated calculations will be revised based on the actual reductions. Revised records of calculations will be maintained on site for EPA review. If the revised calculations indicate that the 0.1 mrem/year NESHAP exemption threshold is exceeded, additional action will be taken to reduce estimated emissions to less than 0.1 mrem/year.
3 Except for a few locations, the piping has been cut near the wall and removed. The only section of piping remaining is in the walls. Pipes that were large enough to foam have been foamed. The assumption handles the case where a pipe gets ruptured during demolition of the wall and for some reason was not completely formed and therefore might release some material. The pipes not removed remained in the MAR with no reduction for foaming.
4 Should one of the methods listed as There are no plans to use be needed during demolition, a Radiological Controls Engineering Re-suspension Calculation would be performed. Revised records of calculations will be maintained on site for EPA review. If the revised calculations indicate that the 0.1 mrem/year NESHAP exemption threshold is exceeded, additional action will be taken to reduce estimated emissions to less than 0.1 mrem/year.
WVDP-606 Rev. 1 Page 5 of 76 Diamond Wire: There are no plans to use this method for MPPB demolition.
Hot-cutting: Oxylance cutting will not be used for MPPB demolition. The shield wall between the Chemical Process Cell (CPC) and the Scrap Removal Room (SRR) will be cut using other hot cutting techniques. Radiological survey data shows that only the CPC side of the shield wall is contaminated.
Standard torch cutting and grinding may also be performed on other areas. When required, the surfaces will be decontaminated to levels acceptable for the technique. Such hot cutting requires notification to the Regulatory Strategy organization and will be reviewed and approved by Radiological Engineering to ensure acceptable contamination levels.
Walls in database that will not be removed Three walls in the database are shared with a structure that will not be demolished, and as such will not be removed. A listing of these walls is provided in Table 1. The MAR for these walls is set to zero.
Table 1: Walls not included current open-air demolition plans Characterization Database ID Area Description 802 UPC N Wall 1624 ULO N Wall 1767 ULO Niche North Wall Sealed containers As discussed in the Alternative Method, radionuclides contained in a sealed container or package are not included in the building inventory for purposes of estimating emissions. The tanks, vessels, pipes and components presented in Table 2 have been coated/foamed/grouted and then sealed. Sealed containers are not included in the environmental MAR.
Table 2: Sealed tanks, vessels and components Characterization Database ID Area Description Prior to Sealing Alpha (Ci)
Prior to Sealing Beta (Ci) 1149 LWC 100' 13D-7 4.020E-03 2.690E-04 1150 LWC 100' 13D-8 5.630E-02 5.570E-04 1151 LWC 100' 3D-2 1.330E-02 1.950E-01 1152 LWC 100' 4D-10 2.520E-01 2.970E-01 1153 LWC 100' 4D-13 2.550E-01 2.200E-01 1154 LWC 100' 4D-8 1.400E-01 1.700E-01 1155 LWC 100' 7D-14 2.460E-01 2.990E-01 1156 LWC 100' 7D-8 4.360E+00 1.040E+00 1551 LWC 100' 7D-2 1.710E+00 2.070E+00 1208 Uranium Product Cell Tank 5D-15B 2.730E-02 3.970E-01
WVDP-606 Rev. 1 Page 6 of 76 Characterization Database ID Area Description Prior to Sealing Alpha (Ci)
Prior to Sealing Beta (Ci) 1209 Uranium Product Cell Tank 5D-15A Compartment #1 2.460E-02 3.570E-01 1210 Uranium Product Cell Tank 5D-15A Compartment #2 1.450E-02 2.110E-01 1629 VWR Sludge (This is in the bottom of the Vent Washer. The sludge has been foamed in place and the washer will be removed as a sealed unit.)
1.710E+00 1.120E+01 1202 VWR Washer North Wall 1.580E-04 1.030E-03 1203 VWR Washer South Wall 8.700E-05 5.690E-04 1204 VWR Washer East Wall 9.720E-05 6.350E-04 1205 VWR Washer West Wall 1.770E-04 1.160E-03 1206 VWR Washer Ceiling 1.690E-04 1.100E-03 1207 VWR Washer Floor 1.490E-02 9.720E-02 1630 Washer Pipe 15V959 CPC Vent 2.82E-02 1.84E-01 1631 Washer Pipe 15V960 PMC to Washer 1.93E-02 1.27E-01 1632 Washer Pipe 15V1007 FRS to Washer 1.12E-02 7.35E-02 1633 Washer Pipe 15V1031 ANA Cell to Washer 1.91E-02 1.25E-01 1634 Washer Pipe 15V985 COA to Washer 2.89E-02 1.89E-01 1635 Washer Pipe 15V1008 Lab Hood to Washer 1.17E-02 7.67E-02 1636 Washer Pipe 15V982 From ULO, PPH, PSC 1.61E-02 1.05E-01 1638 Washer Pipe 15V961 Ex Cells to Washer 1.83E-02 1.20E-01 1639 Washer Pipe 15V986 By-Pass Vent Duct 1.56E-02 1.03E-01 1640 Washer Pipe 15V983 RER Vent 5.72E-03 3.75E-02 1565 Instrument shop Pipe 15V1064 VEC Vent Duct 3.060E-02 1.490E-01 1786 LXA Pipe 15V1064 VEC Vent Duct 2.940E-02 1.430E-01 1787 VWR Pipe 15V1064 Main Vent Duct VWR to VEC 2.60E-02 1.70E-01 2370 VWR Pipe 15V986 1.56E-02 1.03E-01 2371 VWR Pipe 15V985 2.89E-02 1.89E-01 2373 VWR Pipe 15V983 5.72E-03 3.74E-02 2374 VWR Pipe 15V1008 1.17E-02 7.66E-02 2375 VWR Pipe 15V959 2.82E-02 1.84E-01 2376 VWR Pipe 15V960 1.93E-02 1.27E-01 2377 VWR Pipe 15V961 9.69E-03 2.66E-02 2378 VWR Pipe 15V1031 1.91E-02 1.25E-01 2379 VWR Pipe 15V1007 1.12E-02 7.35E-02 2380 VWR Pipe 15CH1208 5.54E-07 5.26E-05 2381 VWR Pipe 15CH748 5.26E-06 1.05E-05 2382 VWR Pipe 15CH1203 5.54E-07 5.26E-05 2383 VWR Pipe 15CH1205 5.54E-07 5.26E-05 2384 VWR Pipe 15CH1209 5.54E-07 5.26E-05 2385 VWR Pipe 15CH1210 5.54E-07 5.26E-05 2386 VWR Pipe 15CH1211 5.54E-07 5.26E-05
WVDP-606 Rev. 1 Page 7 of 76 Characterization Database ID Area Description Prior to Sealing Alpha (Ci)
Prior to Sealing Beta (Ci) 2387 VWR Pipe 15CH1212 5.54E-07 5.26E-05 2388 VWR Pipe 15CH1213 5.54E-07 5.26E-05 1623 ULO Tank 5V-1 8.890E-04 6.030E-05 1831 1C Sampler North Wall 6.140E-04 2.270E-03 1832 1C Sampler South Wall 1.020E-03 3.790E-03 1833 1C Sampler East Wall 2.570E-03 9.510E-03 1834 1C Sampler West Wall 2.570E-03 9.510E-03 1835 1C Sampler Ceiling 1.580E-03 5.820E-03 1836 1C Sampler Floor 2.570E-03 9.510E-03 2967 Cell Access Aisle Pipe 15V961 3.57E-03 9.79E-03 1882 VEC Duct Pipe VEC Roof Duct 1.09E-01 5.29E-01 2989 PCR Diverter Box 2.13E-04 1.42E-01 1998 XC-3 Pipe 15V956 1.97E-05 4.21E-02 1999 XC-3 Pipe 15V957 3.29E-05 7.01E-02 2183 XC-2 Pipe 15V956 3.94E-05 8.41E-02 Floor and wall liners removed intact Several rooms and niches have liners that will be fixed, folded and removed as sealed units. Table 3 provides a listing of the liners, which are not included in the environmental MAR.
Table 3: Sealed wall and floor liners Characterization Database ID Area Description Prior to Sealing Alpha (Ci)
Prior to Sealing Beta (Ci) 1789 UWA Niche 1 N Wall 7.16E-03 3.18E-03 1790 UWA Niche 1 S Wall 7.16E-03 3.18E-03 1791 UWA Niche 1 E Wall 9.85E-03 4.37E-03 1792 UWA Niche 1 W Wall 9.85E-03 4.37E-03 1793 UWA Niche 1 Floor 1.97E-02 8.74E-03 1795 UWA Niche 2 N Wall 1.05E-03 4.66E-04 1796 UWA Niche 2 S Wall 1.05E-03 4.66E-04 1797 UWA Niche 2 W Wall 1.44E-03 6.40E-04 1798 UWA Niche 2 E Wall 1.44E-03 6.40E-04 1800 UWA Niche 2 Floor 2.88E-03 1.28E-03 1801 UWA Niche 4 N Wall 7.34E-04 3.25E-04 1802 UWA Niche 4 S Wall 7.34E-04 3.25E-04 1803 UWA Niche 4 E Wall 8.82E-04 3.91E-04 1804 UWA Niche 4 W Wall 8.82E-04 3.91E-04 1806 UWA Niche 4 Floor 1.09E-03 4.83E-04
WVDP-606 Rev. 1 Page 8 of 76 Characterization Database ID Area Description Prior to Sealing Alpha (Ci)
Prior to Sealing Beta (Ci) 1807 UWA Niche 3 N Wall 5.57E-03 1.08E-02 1808 UWA Niche 3 S Wall 5.57E-03 1.08E-02 1809 UWA Niche 3 E Wall 1.53E-02 2.97E-02 1810 UWA Niche 3 W Wall 1.53E-02 2.97E-02 1812 UWA Niche 3 Floor 1.53E-02 2.97E-02 1012 CCR Floor 5.42E-02 7.44E-01 1043 SC2 Floor 2.03E-04 8.79E-04 1050 HC3 Floor 2.09E-02 9.28E-02 1051 HC1 N Wall 8.68E-03 6.28E-03 1056 HC1 Floor 1.12E-01 8.14E-02 1067 HC2 Floor 1.49E-03 6.61E-03 1073 HC4 Floor 1.82E-03 2.83E-04 1085 HC5 Floor 2.59E-03 1.15E-02 1125 PMCR Floor 6.85E-02 6.00E-01 Radionuclides Included in the Environmental MAR Two radionuclides that are typically seen in environmental samples, but that are not included in the Characterization Database are Tc-99 and I-129. To account for these radionuclides a ratio relative to Cs-137 was developed that is based on the characterization of Reactor Fuel Reprocessed at West Valley5. The ratios are:
Tc-99: 4.58e 04 I-129: 9.60E 07 There are two radionuclides that exist in secular equilibrium with their parent isotope and which are also not included in the Characterization Database. Ba-137m is in secular equilibrium with Cs-137 and Y-90 is in secular equilibrium with Sr-90. Both of these radionuclides have been added to the Environmental MAR; however, care should be exercised when modelling these radionuclides as some dose codes include them by default when the parent isotope is entered.
Environmental MAR The Environmental MAR is the MAR for purposes of radiological air emissions calculations as they pertain to environmental regulatory compliance activities. The Environmental MAR is equal to the total 5 From Attachment A of WVDP-EIS-014.
WVDP-606 Rev. 1 Page 9 of 76 MAR minus the MAR in sealed containers and excluded walls. The Environmental MAR also includes estimates of the MAR for I-129 and Tc-99. Appendix A contains a detailed listing of all sources and the Environmental MAR associated with that source. The inventory expected to be impacted by each demolition method is presented in Table 4.
Table 4: Environment MAR Radionuclide Hydraulic Hammer Technique Mechanical Shear Technique OGC Corner Concrete Saw Technique Hot Cutting Technique Total Cs-137 (Ci) 2.48E+00 2.24E-01 1.74E+01 2.29E-04 2.01E+01 Sr-90 (Ci) 3.72E+00 1.84E-01 4.67E+01 6.14E-04 5.06E+01 Cm-243 (Ci) 2.55E-04 1.31E-05 2.09E-03 2.75E-08 2.36E-03 Cm-244 (Ci) 5.62E-03 5.11E-04 4.67E-02 6.14E-07 5.28E-02 Np-237 (Ci) 1.59E-03 1.32E-03 1.99E-04 2.61E-09 3.11E-03 Am-241 (Ci) 1.94E+00 3.46E-02 2.51E+00 3.30E-05 4.48E+00 Pu-238 (Ci) 6.10E-01 1.03E-02 8.76E-01 1.15E-05 1.50E+00 Pu-239 (Ci) 4.97E-01 7.52E-03 6.46E-01 8.49E-06 1.15E+00 Pu-240 (Ci) 3.79E-01 5.48E-03 4.89E-01 6.43E-06 8.74E-01 Pu-241 (Ci) 5.99E+00 9.61E-02 7.63E+00 1.00E-04 1.37E+01 U-232 (Ci) 1.89E-02 3.51E-04 6.15E-02 8.08E-07 8.08E-02 U-233 (Ci) 1.24E-02 9.59E-05 2.40E-02 3.16E-07 3.65E-02 U-234 (Ci) 5.92E-03 3.78E-05 1.14E-02 1.50E-07 1.74E-02 U-235 (Ci) 5.01E-04 1.01E-05 8.00E-05 1.05E-09 5.91E-04 U-238 (Ci) 5.86E-03 9.47E-06 8.95E-04 1.18E-08 6.77E-03 I-129 (Ci) 2.38E-06 2.15E-07 1.67E-05 2.20E-10 1.93E-05 Tc-99 (Ci) 1.13E-03 1.03E-04 7.98E-03 1.05E-07 9.21E-03 Ba-137m (Ci) 2.48E+00 2.24E-01 1.74E+01 2.29E-04 2.01E+01 Y-90 (Ci) 3.72E+00 1.84E-01 4.67E+01 6.14E-04 5.06E+01
WVDP-606 Rev. 1 Page 10 of 76 Appendix A List of each Component of the Environmental MAR grouped by Proposed Demolition Method
WVDP-606 Rev. 1 Page 11 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1835 1C Sampler Ceiling 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1833 1C Sampler E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1836 1C Sampler Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1831 1C Sampler N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1832 1C Sampler S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1834 1C Sampler W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2968 1C Sampler Pipe 13P131 5.35E-08 9.25E-08 0.00E+00 0.00E+00 9.68E-14 1.01E-07 5.21E-08 3.89E-08 3.02E-08 6.79E-07 0.00E+00 5.83E-19 4.49E-13 1.15E-16 0.00E+00 5.13E-14 2.45E-11 2969 1C Sampler Pipe 13P131 4.18E-08 7.22E-08 0.00E+00 0.00E+00 7.56E-14 7.89E-08 4.07E-08 3.04E-08 2.36E-08 5.30E-07 0.00E+00 4.55E-19 3.50E-13 8.98E-17 0.00E+00 4.01E-14 1.91E-11 2970 1C Sampler Pipe 3P37 8.53E-09 1.48E-08 0.00E+00 0.00E+00 1.54E-14 1.61E-08 8.32E-09 6.20E-09 4.82E-09 1.08E-07 0.00E+00 9.30E-20 7.16E-14 1.83E-17 0.00E+00 8.19E-15 3.91E-12 2971 1C Sampler Pipe 3P37 7.36E-09 1.27E-08 0.00E+00 0.00E+00 1.33E-14 1.39E-08 7.18E-09 5.35E-09 4.16E-09 9.35E-08 0.00E+00 8.03E-20 6.18E-14 1.58E-17 0.00E+00 7.07E-15 3.37E-12 2972 1C Sampler Pipe 3P81 7.62E-07 1.32E-06 0.00E+00 0.00E+00 1.38E-12 1.44E-06 7.43E-07 5.54E-07 4.30E-07 9.68E-06 0.00E+00 8.30E-18 6.39E-12 1.64E-15 0.00E+00 7.31E-13 3.49E-10 2973 1C Sampler Pipe 3P81 6.23E-07 1.08E-06 0.00E+00 0.00E+00 1.13E-12 1.18E-06 6.07E-07 4.53E-07 3.52E-07 7.91E-06 0.00E+00 6.79E-18 5.22E-12 1.34E-15 0.00E+00 5.98E-13 2.85E-10 2974 1C Sampler Pipe 4P469 9.93E-09 1.72E-08 0.00E+00 0.00E+00 1.80E-14 1.88E-08 9.68E-09 7.22E-09 5.61E-09 1.26E-07 0.00E+00 1.08E-19 8.33E-14 2.13E-17 0.00E+00 9.53E-15 4.55E-12 2975 1C Sampler Pipe 4P469 8.02E-09 1.39E-08 0.00E+00 0.00E+00 1.45E-14 1.52E-08 7.82E-09 5.83E-09 4.53E-09 1.02E-07 0.00E+00 8.74E-20 6.73E-14 1.72E-17 0.00E+00 7.70E-15 3.67E-12 2979 1C Sampler Pipe 4P622 9.60E-09 1.66E-08 0.00E+00 0.00E+00 1.74E-14 1.81E-08 9.36E-09 6.98E-09 5.42E-09 1.22E-07 0.00E+00 1.05E-19 8.05E-14 2.06E-17 0.00E+00 9.21E-15 4.40E-12 2980 1C Sampler Pipe 7P104 4.43E-06 7.67E-06 0.00E+00 0.00E+00 8.02E-12 8.38E-06 4.32E-06 3.22E-06 2.50E-06 5.63E-05 0.00E+00 4.83E-17 3.72E-11 9.53E-15 0.00E+00 4.25E-12 2.03E-09 2981 1C Sampler Pipe 7P104 3.85E-06 6.65E-06 0.00E+00 0.00E+00 6.96E-12 7.27E-06 3.75E-06 2.80E-06 2.17E-06 4.88E-05 0.00E+00 4.19E-17 3.23E-11 8.27E-15 0.00E+00 3.69E-12 1.76E-09 2982 1C Sampler Pipe 7P139 3.92E-08 6.78E-08 0.00E+00 0.00E+00 7.09E-14 7.41E-08 3.82E-08 2.85E-08 2.21E-08 4.98E-07 0.00E+00 4.27E-19 3.29E-13 8.43E-17 0.00E+00 3.76E-14 1.80E-11 2983 1C Sampler Pipe 7P139 3.34E-08 5.78E-08 0.00E+00 0.00E+00 6.05E-14 6.31E-08 3.26E-08 2.43E-08 1.89E-08 4.24E-07 0.00E+00 3.64E-19 2.80E-13 7.18E-17 0.00E+00 3.21E-14 1.53E-11 1915 ADA Ceiling 2.31E-05 2.16E-05 2.02E-09 3.85E-08 3.04E-10 4.54E-06 6.04E-07 1.25E-06 6.62E-07 1.04E-05 6.73E-10 1.60E-09 1.34E-10 6.99E-11 1.15E-09 2.21E-11 1.06E-08 1913 ADA E Wall 4.95E-05 4.65E-05 4.35E-09 8.27E-08 6.54E-10 9.75E-06 1.30E-06 2.69E-06 1.42E-06 2.23E-05 1.45E-09 3.45E-09 2.89E-10 1.50E-10 2.47E-09 4.75E-11 2.27E-08 1916 ADA Floor 3.81E-03 3.58E-03 3.35E-07 6.36E-06 5.03E-08 7.51E-04 9.99E-05 2.07E-04 1.09E-04 1.72E-03 1.11E-07 2.65E-07 2.22E-08 1.15E-08 1.90E-07 3.66E-09 1.75E-06 1911 ADA N Wall 9.08E-06 8.52E-06 7.97E-10 1.52E-08 1.20E-10 1.79E-06 2.38E-07 4.94E-07 2.61E-07 4.09E-06 2.65E-10 6.32E-10 5.29E-11 2.75E-11 4.53E-10 8.71E-12 4.16E-09 1912 ADA S Wall 5.62E-06 5.28E-06 4.94E-10 9.39E-09 7.42E-11 1.11E-06 1.47E-07 3.06E-07 1.61E-07 2.54E-06 1.64E-10 3.91E-10 3.28E-11 1.70E-11 2.81E-10 5.40E-12 2.57E-09 1914 ADA W Wall 4.35E-06 4.08E-06 3.82E-10 7.26E-09 5.74E-11 8.56E-07 1.14E-07 2.37E-07 1.25E-07 1.96E-06 1.27E-10 3.03E-10 2.53E-11 1.32E-11 2.17E-10 4.17E-12 1.99E-09 816 ANA Aisles 131' Ceiling 9.80E-05 3.60E-05 4.84E-09 1.22E-07 2.88E-09 5.15E-06 1.57E-06 1.18E-06 8.87E-07 1.55E-05 1.03E-06 8.08E-08 3.76E-08 1.75E-09 2.53E-08 9.41E-11 4.49E-08 822 ANA Aisles 131' Ceiling 1.57E-05 5.75E-06 7.73E-10 1.94E-08 4.60E-10 8.22E-07 2.50E-07 1.88E-07 1.42E-07 2.47E-06 1.64E-07 1.29E-08 6.01E-09 2.80E-10 4.04E-09 1.50E-11 7.17E-09 828 ANA Aisles 131' Ceiling 1.81E-05 6.66E-06 8.96E-10 2.25E-08 5.33E-10 9.52E-07 2.90E-07 2.18E-07 1.64E-07 2.87E-06 1.90E-07 1.49E-08 6.97E-09 3.25E-10 4.68E-09 1.74E-11 8.31E-09 834 ANA Aisles 131' Ceiling 1.07E-05 3.92E-06 5.28E-10 1.32E-08 3.14E-10 5.61E-07 1.71E-07 1.28E-07 9.67E-08 1.69E-06 1.12E-07 8.80E-09 4.10E-09 1.91E-10 2.76E-09 1.03E-11 4.89E-09 840 ANA Aisles 131' Ceiling 1.05E-04 3.87E-05 5.20E-09 1.31E-07 3.10E-09 5.53E-06 1.69E-06 1.26E-06 9.53E-07 1.66E-05 1.11E-06 8.68E-08 4.05E-08 1.89E-09 2.72E-08 1.01E-10 4.82E-08 846 ANA Aisles 131' Ceiling 6.63E-06 2.43E-06 3.27E-10 8.22E-09 1.95E-10 3.48E-07 1.06E-07 7.95E-08 6.00E-08 1.05E-06 6.96E-08 5.46E-09 2.55E-09 1.19E-10 1.71E-09 6.36E-12 3.04E-09 852 ANA Aisles 131' Ceiling 4.15E-06 1.52E-06 2.05E-10 5.14E-09 1.22E-10 2.18E-07 6.64E-08 4.98E-08 3.75E-08 6.55E-07 4.36E-08 3.42E-09 1.59E-09 7.42E-11 1.07E-09 3.98E-12 1.90E-09 814 ANA Aisles 131' E Wall 1.80E-05 6.60E-06 8.89E-10 2.23E-08 5.29E-10 9.45E-07 2.88E-07 2.16E-07 1.63E-07 2.84E-06 1.89E-07 1.48E-08 6.91E-09 3.22E-10 4.64E-09 1.73E-11 8.24E-09 820 ANA Aisles 131' E Wall 7.68E-07 2.82E-07 3.79E-11 9.52E-10 2.26E-11 4.03E-08 1.23E-08 9.22E-09 6.95E-09 1.21E-07 8.07E-09 6.33E-10 2.95E-10 1.37E-11 1.98E-10 7.37E-13 3.52E-10
WVDP-606 Rev. 1 Page 12 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 826 ANA Aisles 131' E Wall 9.44E-06 3.46E-06 4.66E-10 1.17E-08 2.77E-10 4.95E-07 1.51E-07 1.13E-07 8.54E-08 1.49E-06 9.91E-08 7.78E-09 3.62E-09 1.69E-10 2.43E-09 9.06E-12 4.32E-09 832 ANA Aisles 131' E Wall 1.02E-06 3.76E-07 5.06E-11 1.27E-09 3.01E-11 5.38E-08 1.64E-08 1.23E-08 9.27E-09 1.62E-07 1.08E-08 8.44E-10 3.93E-10 1.83E-11 2.64E-10 9.83E-13 4.69E-10 838 ANA Aisles 131' E Wall 2.57E-06 9.42E-07 1.27E-10 3.18E-09 7.55E-11 1.35E-07 4.11E-08 3.08E-08 2.32E-08 4.06E-07 2.70E-08 2.12E-09 9.86E-10 4.60E-11 6.62E-10 2.46E-12 1.18E-09 844 ANA Aisles 131' E Wall 5.14E-07 1.88E-07 2.54E-11 6.37E-10 1.51E-11 2.70E-08 8.22E-09 6.16E-09 4.65E-09 8.11E-08 5.39E-09 4.23E-10 1.97E-10 9.19E-12 1.32E-10 4.93E-13 2.35E-10 817 ANA Aisles 131' Floor 9.58E-06 3.52E-06 4.73E-10 1.19E-08 2.82E-10 5.03E-07 1.53E-07 1.15E-07 8.67E-08 1.51E-06 1.01E-07 7.90E-09 3.68E-09 1.72E-10 2.47E-09 9.20E-12 4.39E-09 823 ANA Aisles 131' Floor 2.64E-04 9.69E-05 1.30E-08 3.27E-07 7.76E-09 1.39E-05 4.23E-06 3.17E-06 2.39E-06 4.17E-05 2.77E-06 2.18E-07 1.01E-07 4.73E-09 6.81E-08 2.54E-10 1.21E-07 829 ANA Aisles 131' Floor 5.54E-06 2.03E-06 2.74E-10 6.87E-09 1.63E-10 2.91E-07 8.86E-08 6.65E-08 5.01E-08 8.75E-07 5.81E-08 4.56E-09 2.13E-09 9.91E-11 1.43E-09 5.32E-12 2.54E-09 835 ANA Aisles 131' Floor 3.56E-06 1.31E-06 1.76E-10 4.42E-09 1.05E-10 1.87E-07 5.70E-08 4.28E-08 3.22E-08 5.63E-07 3.74E-08 2.94E-09 1.37E-09 6.38E-11 9.19E-10 3.42E-12 1.63E-09 841 ANA Aisles 131' Floor 1.09E-04 4.00E-05 5.38E-09 1.35E-07 3.20E-09 5.72E-06 1.74E-06 1.31E-06 9.86E-07 1.72E-05 1.14E-06 8.98E-08 4.19E-08 1.95E-09 2.81E-08 1.05E-10 4.99E-08 847 ANA Aisles 131' Floor 1.42E-06 5.21E-07 7.01E-11 1.76E-09 4.17E-11 7.45E-08 2.27E-08 1.70E-08 1.28E-08 2.24E-07 1.49E-08 1.17E-09 5.45E-10 2.54E-11 3.66E-10 1.36E-12 6.50E-10 853 ANA Aisles 131' Floor 5.93E-07 2.17E-07 2.93E-11 7.35E-10 1.74E-11 3.11E-08 9.48E-09 7.11E-09 5.36E-09 9.36E-08 6.22E-09 4.88E-10 2.28E-10 1.06E-11 1.53E-10 5.69E-13 2.71E-10 812 ANA Aisles 131' N Wall 1.28E-05 4.70E-06 6.32E-10 1.59E-08 3.76E-10 6.72E-07 2.05E-07 1.54E-07 1.16E-07 2.02E-06 1.34E-07 1.05E-08 4.92E-09 2.29E-10 3.30E-09 1.23E-11 5.86E-09 818 ANA Aisles 131' N Wall 4.07E-05 1.49E-05 2.01E-09 5.04E-08 1.20E-09 2.14E-06 6.51E-07 4.88E-07 3.68E-07 6.43E-06 4.27E-07 3.35E-08 1.56E-08 7.28E-10 1.05E-08 3.90E-11 1.86E-08 824 ANA Aisles 131' N Wall 2.44E-06 8.94E-07 1.20E-10 3.02E-09 7.16E-11 1.28E-07 3.90E-08 2.92E-08 2.20E-08 3.85E-07 2.56E-08 2.01E-09 9.35E-10 4.36E-11 6.28E-10 2.34E-12 1.12E-09 830 ANA Aisles 131' N Wall 6.16E-06 2.26E-06 3.04E-10 7.64E-09 1.81E-10 3.23E-07 9.86E-08 7.39E-08 5.57E-08 9.73E-07 6.47E-08 5.08E-09 2.37E-09 1.10E-10 1.59E-09 5.91E-12 2.82E-09 836 ANA Aisles 131' N Wall 1.37E-04 5.02E-05 6.76E-09 1.70E-07 4.02E-09 7.18E-06 2.19E-06 1.64E-06 1.24E-06 2.16E-05 1.44E-06 1.13E-07 5.25E-08 2.45E-09 3.53E-08 1.31E-10 6.27E-08 842 ANA Aisles 131' N Wall 2.00E-06 7.36E-07 9.90E-11 2.49E-09 5.89E-11 1.05E-07 3.21E-08 2.41E-08 1.81E-08 3.17E-07 2.10E-08 1.65E-09 7.70E-10 3.59E-11 5.17E-10 1.92E-12 9.18E-10 848 ANA Aisles 131' N Wall 1.80E-06 6.60E-07 8.89E-11 2.23E-09 5.29E-11 9.45E-08 2.88E-08 2.16E-08 1.63E-08 2.84E-07 1.89E-08 1.48E-09 6.91E-10 3.22E-11 4.64E-10 1.73E-12 8.24E-10 813 ANA Aisles 131' S Wall 1.92E-06 7.06E-07 9.50E-11 2.39E-09 5.66E-11 1.01E-07 3.08E-08 2.31E-08 1.74E-08 3.04E-07 2.02E-08 1.59E-09 7.39E-10 3.44E-11 4.96E-10 1.85E-12 8.81E-10 819 ANA Aisles 131' S Wall 1.73E-05 6.34E-06 8.53E-10 2.14E-08 5.08E-10 9.06E-07 2.76E-07 2.07E-07 1.56E-07 2.73E-06 1.81E-07 1.42E-08 6.63E-09 3.09E-10 4.45E-09 1.66E-11 7.91E-09 825 ANA Aisles 131' S Wall 2.82E-06 1.04E-06 1.39E-10 3.50E-09 8.30E-11 1.48E-07 4.52E-08 3.39E-08 2.56E-08 4.46E-07 2.96E-08 2.33E-09 1.08E-09 5.05E-11 7.29E-10 2.71E-12 1.29E-09 831 ANA Aisles 131' S Wall 5.30E-06 1.95E-06 2.62E-10 6.58E-09 1.56E-10 2.78E-07 8.49E-08 6.36E-08 4.80E-08 8.38E-07 5.57E-08 4.37E-09 2.04E-09 9.49E-11 1.37E-09 5.09E-12 2.43E-09 837 ANA Aisles 131' S Wall 2.55E-05 9.34E-06 1.26E-09 3.16E-08 7.48E-10 1.34E-06 4.07E-07 3.05E-07 2.30E-07 4.02E-06 2.67E-07 2.10E-08 9.78E-09 4.56E-10 6.57E-09 2.44E-11 1.17E-08 843 ANA Aisles 131' S Wall 4.63E-07 1.70E-07 2.29E-11 5.74E-10 1.36E-11 2.43E-08 7.41E-09 5.56E-09 4.19E-09 7.32E-08 4.86E-09 3.82E-10 1.78E-10 8.29E-12 1.19E-10 4.45E-13 2.12E-10 849 ANA Aisles 131' S Wall 1.41E-06 5.18E-07 6.97E-11 1.75E-09 4.15E-11 7.41E-08 2.26E-08 1.69E-08 1.28E-08 2.23E-07 1.48E-08 1.16E-09 5.42E-10 2.53E-11 3.64E-10 1.36E-12 6.47E-10 815 ANA Aisles 131' W Wall 5.89E-06 2.16E-06 2.91E-10 7.30E-09 1.73E-10 3.09E-07 9.42E-08 7.07E-08 5.33E-08 9.30E-07 6.18E-08 4.85E-09 2.26E-09 1.05E-10 1.52E-09 5.65E-12 2.70E-09 827 ANA Aisles 131' W Wall 3.49E-06 1.28E-06 1.72E-10 4.33E-09 1.03E-10 1.83E-07 5.58E-08 4.19E-08 3.16E-08 5.51E-07 3.66E-08 2.88E-09 1.34E-09 6.25E-11 9.00E-10 3.35E-12 1.60E-09 833 ANA Aisles 131' W Wall 2.31E-05 8.48E-06 1.14E-09 2.87E-08 6.80E-10 1.21E-06 3.70E-07 2.77E-07 2.09E-07 3.65E-06 2.43E-07 1.90E-08 8.88E-09 4.14E-10 5.96E-09 2.22E-11 1.06E-08 839 ANA Aisles 131' W Wall 1.02E-05 3.76E-06 5.06E-10 1.27E-08 3.01E-10 5.38E-07 1.64E-07 1.23E-07 9.27E-08 1.62E-06 1.08E-07 8.44E-09 3.93E-09 1.83E-10 2.64E-09 9.83E-12 4.69E-09 845 ANA Aisles 131' W Wall 1.43E-05 5.26E-06 7.08E-10 1.78E-08 4.22E-10 7.53E-07 2.29E-07 1.72E-07 1.30E-07 2.27E-06 1.51E-07 1.18E-08 5.51E-09 2.57E-10 3.70E-09 1.38E-11 6.57E-09 851 ANA Aisles 131' W Wall 2.16E-06 7.92E-07 1.07E-10 2.68E-09 6.34E-11 1.13E-07 3.45E-08 2.59E-08 1.95E-08 3.41E-07 2.27E-08 1.78E-09 8.29E-10 3.86E-11 5.57E-10 2.07E-12 9.88E-10 858 ANA Chemistry LAB 131' Ceiling 2.22E-05 8.13E-06 1.09E-09 2.75E-08 6.52E-10 1.16E-06 3.55E-07 2.66E-07 2.01E-07 3.50E-06 2.33E-07 1.83E-08 8.51E-09 3.97E-10 5.72E-09 2.13E-11 1.02E-08 856 ANA Chemistry LAB 131' E Wall 5.17E-08 1.90E-08 2.55E-12 6.41E-11 1.52E-12 2.72E-09 8.28E-10 6.21E-10 4.68E-10 8.17E-09 5.43E-10 4.26E-11 1.99E-11 9.26E-13 1.33E-11 4.97E-14 2.37E-11 859 ANA Chemistry LAB 131' Floor 3.16E-06 1.16E-06 1.56E-10 3.92E-09 9.29E-11 1.66E-07 5.06E-08 3.79E-08 2.86E-08 4.99E-07 3.32E-08 2.60E-09 1.21E-09 5.66E-11 8.15E-10 3.03E-12 1.45E-09
WVDP-606 Rev. 1 Page 13 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 854 ANA Chemistry LAB 131' N Wall 1.44E-05 5.29E-06 7.12E-10 1.79E-08 4.24E-10 7.57E-07 2.31E-07 1.73E-07 1.30E-07 2.28E-06 1.51E-07 1.19E-08 5.53E-09 2.58E-10 3.72E-09 1.38E-11 6.60E-09 855 ANA Chemistry LAB 131' S Wall 7.19E-06 2.64E-06 3.55E-10 8.92E-09 2.11E-10 3.78E-07 1.15E-07 8.63E-08 6.51E-08 1.14E-06 7.55E-08 5.93E-09 2.76E-09 1.29E-10 1.86E-09 6.90E-12 3.29E-09 857 ANA Chemistry LAB 131' W Wall 1.13E-05 4.16E-06 5.60E-10 1.41E-08 3.33E-10 5.95E-07 1.81E-07 1.36E-07 1.03E-07 1.79E-06 1.19E-07 9.34E-09 4.35E-09 2.03E-10 2.93E-09 1.09E-11 5.19E-09 976 ARC Ceiling 4.53E-04 4.89E-05 1.30E-09 2.85E-08 3.32E-10 8.65E-05 1.98E-05 3.01E-05 2.25E-05 1.82E-04 5.07E-08 8.47E-15 7.07E-10 3.56E-13 6.34E-09 4.35E-10 2.08E-07 974 ARC E Wall 1.00E-04 1.08E-05 2.87E-10 6.29E-09 7.33E-11 1.91E-05 4.38E-06 6.65E-06 4.97E-06 4.03E-05 1.12E-08 1.87E-15 1.56E-10 7.86E-14 1.40E-09 9.62E-11 4.59E-08 972 ARC N Wall 3.59E-05 3.88E-06 1.03E-10 2.26E-09 2.63E-11 6.86E-06 1.57E-06 2.39E-06 1.78E-06 1.44E-05 4.02E-09 6.72E-16 5.60E-11 2.82E-14 5.03E-10 3.45E-11 1.65E-08 973 ARC S Wall 1.22E-03 1.32E-04 3.48E-09 7.65E-08 8.92E-10 2.33E-04 5.32E-05 8.09E-05 6.04E-05 4.90E-04 1.36E-07 2.28E-14 1.90E-09 9.56E-13 1.71E-08 1.17E-09 5.58E-07 975 ARC W Wall 2.07E-04 2.23E-05 5.91E-10 1.30E-08 1.51E-10 3.95E-05 9.03E-06 1.37E-05 1.03E-05 8.31E-05 2.31E-08 3.86E-15 3.22E-10 1.62E-13 2.89E-09 1.98E-10 9.47E-08 2988 ARPR Ceiling 1.07E-04 1.16E-05 3.07E-10 6.74E-09 7.86E-11 2.05E-05 4.69E-06 7.13E-06 5.33E-06 4.32E-05 1.20E-08 2.01E-15 1.68E-10 8.43E-14 1.50E-09 1.03E-10 4.92E-08 2986 ARPR E Wall 3.51E-05 3.79E-06 1.00E-10 2.20E-09 2.57E-11 6.71E-06 1.53E-06 2.33E-06 1.74E-06 1.41E-05 3.93E-09 6.57E-16 5.48E-11 2.76E-14 4.92E-10 3.37E-11 1.61E-08 2984 ARPR N Wall 4.17E-05 4.50E-06 1.19E-10 2.62E-09 3.05E-11 7.96E-06 1.82E-06 2.77E-06 2.07E-06 1.68E-05 4.67E-09 7.80E-16 6.50E-11 3.27E-14 5.84E-10 4.00E-11 1.91E-08 2985 ARPR S Wall 6.00E-05 6.48E-06 1.72E-10 3.77E-09 4.39E-11 1.15E-05 2.62E-06 3.99E-06 2.98E-06 2.41E-05 6.72E-09 1.12E-15 9.36E-11 4.71E-14 8.40E-10 5.76E-11 2.75E-08 2987 ARPR W Wall 3.51E-05 3.79E-06 1.00E-10 2.20E-09 2.57E-11 6.71E-06 1.53E-06 2.33E-06 1.74E-06 1.41E-05 3.93E-09 6.57E-16 5.48E-11 2.76E-14 4.92E-10 3.37E-11 1.61E-08 748 CAS Storage Ceiling 7.83E-07 2.87E-07 3.87E-11 9.71E-10 2.30E-11 4.11E-08 1.25E-08 9.39E-09 7.08E-09 1.24E-07 8.22E-09 6.45E-10 3.01E-10 1.40E-11 2.02E-10 7.51E-13 3.58E-10 746 CAS Storage E Wall 1.38E-07 5.07E-08 6.83E-12 1.71E-10 4.06E-12 7.26E-09 2.21E-09 1.66E-09 1.25E-09 2.18E-08 1.45E-09 1.14E-10 5.31E-11 2.47E-12 3.57E-11 1.33E-13 6.33E-11 744 CAS Storage N Wall 1.10E-06 4.03E-07 5.42E-11 1.36E-09 3.23E-11 5.76E-08 1.76E-08 1.32E-08 9.93E-09 1.73E-07 1.15E-08 9.04E-10 4.21E-10 1.96E-11 2.83E-10 1.05E-12 5.03E-10 745 CAS Storage S Wall 8.63E-07 3.17E-07 4.26E-11 1.07E-09 2.54E-11 4.53E-08 1.38E-08 1.04E-08 7.81E-09 1.36E-07 9.06E-09 7.11E-10 3.31E-10 1.55E-11 2.23E-10 8.29E-13 3.95E-10 747 CAS Storage W Wall 1.10E-07 4.05E-08 5.46E-12 1.37E-10 3.25E-12 5.80E-09 1.77E-09 1.33E-09 1.00E-09 1.75E-08 1.16E-09 9.10E-11 4.24E-11 1.98E-12 2.85E-11 1.06E-13 5.06E-11 1011 CCR 131' Ceiling 1.42E-03 3.82E-03 1.71E-07 3.82E-06 1.62E-08 2.05E-04 7.16E-05 5.28E-05 4.00E-05 6.24E-04 5.03E-06 1.97E-06 9.33E-07 6.54E-09 7.32E-08 1.37E-09 6.52E-07 1009 CCR 131' E Wall 1.62E-03 4.35E-03 1.95E-07 4.35E-06 1.85E-08 2.34E-04 8.16E-05 6.02E-05 4.56E-05 7.11E-04 5.73E-06 2.24E-06 1.06E-06 7.45E-09 8.34E-08 1.56E-09 7.43E-07 1012 CCR 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1007 CCR 131' N Wall 1.89E-04 5.06E-04 2.27E-08 5.06E-07 2.15E-09 2.72E-05 9.50E-06 7.01E-06 5.31E-06 8.27E-05 6.67E-07 2.61E-07 1.24E-07 8.67E-10 9.71E-09 1.81E-10 8.65E-08 1008 CCR 131' S Wall 6.41E-04 1.72E-03 7.70E-08 1.72E-06 7.31E-09 9.23E-05 3.23E-05 2.38E-05 1.80E-05 2.81E-04 2.26E-06 8.85E-07 4.20E-07 2.94E-09 3.30E-08 6.16E-10 2.94E-07 1010 CCR 131' W Wall 1.48E-03 3.97E-03 1.78E-07 3.97E-06 1.69E-08 2.13E-04 7.45E-05 5.49E-05 4.16E-05 6.49E-04 5.23E-06 2.04E-06 9.70E-07 6.80E-09 7.61E-08 1.42E-09 6.78E-07 811 Cell Access Aisle CAA Ceiling 2.52E-05 9.26E-06 1.25E-09 3.13E-08 7.42E-10 1.32E-06 4.04E-07 3.03E-07 2.28E-07 3.99E-06 2.65E-07 2.08E-08 9.69E-09 4.52E-10 6.51E-09 2.42E-11 1.16E-08 809 Cell Access Aisle CAA E Wall 2.63E-05 9.64E-06 1.30E-09 3.26E-08 7.72E-10 1.38E-06 4.20E-07 3.15E-07 2.38E-07 4.15E-06 2.76E-07 2.16E-08 1.01E-08 4.70E-10 6.78E-09 2.52E-11 1.20E-08 807 Cell Access Aisle CAA N Wall 1.48E-05 5.42E-06 7.30E-10 1.83E-08 4.34E-10 7.76E-07 2.36E-07 1.77E-07 1.34E-07 2.33E-06 1.55E-07 1.22E-08 5.67E-09 2.65E-10 3.81E-09 1.42E-11 6.77E-09 808 Cell Access Aisle CAA S Wall 1.48E-05 5.42E-06 7.30E-10 1.83E-08 4.34E-10 7.76E-07 2.36E-07 1.77E-07 1.34E-07 2.33E-06 1.55E-07 1.22E-08 5.67E-09 2.65E-10 3.81E-09 1.42E-11 6.77E-09 810 Cell Access Aisle CAA W Wall 1.87E-05 6.87E-06 9.25E-10 2.32E-08 5.51E-10 9.83E-07 3.00E-07 2.25E-07 1.69E-07 2.96E-06 1.97E-07 1.54E-08 7.19E-09 3.35E-10 4.83E-09 1.80E-11 8.58E-09 743 Central Alarm Station CAS Ceiling 9.66E-07 3.54E-07 4.77E-11 1.20E-09 2.84E-11 5.07E-08 1.54E-08 1.16E-08 8.74E-09 1.53E-07 1.01E-08 7.96E-10 3.71E-10 1.73E-11 2.49E-10 9.27E-13 4.42E-10 741 Central Alarm Station CAS E Wall 5.21E-06 1.91E-06 2.57E-10 6.46E-09 1.53E-10 2.73E-07 8.33E-08 6.25E-08 4.71E-08 8.23E-07 5.47E-08 4.29E-09 2.00E-09 9.32E-11 1.34E-09 5.00E-12 2.39E-09 739 Central Alarm Station CAS N Wall 6.83E-07 2.50E-07 3.37E-11 8.46E-10 2.01E-11 3.58E-08 1.09E-08 8.19E-09 6.18E-09 1.08E-07 7.17E-09 5.62E-10 2.62E-10 1.22E-11 1.76E-10 6.55E-13 3.13E-10 740 Central Alarm Station CAS S Wall 1.90E-06 6.98E-07 9.40E-11 2.36E-09 5.59E-11 9.99E-08 3.04E-08 2.28E-08 1.72E-08 3.01E-07 2.00E-08 1.57E-09 7.30E-10 3.40E-11 4.91E-10 1.83E-12 8.71E-10 742 Central Alarm Station CAS W Wall 9.44E-07 3.46E-07 4.66E-11 1.17E-09 2.77E-11 4.95E-08 1.51E-08 1.13E-08 8.54E-09 1.49E-07 9.91E-09 7.78E-10 3.62E-10 1.69E-11 2.43E-10 9.06E-13 4.32E-10
WVDP-606 Rev. 1 Page 14 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 932 COA 114' Ceiling 7.02E-04 2.58E-04 3.47E-08 8.71E-07 2.06E-08 3.69E-05 1.12E-05 8.43E-06 6.36E-06 1.11E-04 7.37E-06 5.79E-07 2.70E-07 1.26E-08 1.81E-07 6.74E-10 3.22E-07 930 COA 114' East Wall 3.10E-05 1.14E-05 1.53E-09 3.85E-08 9.12E-10 1.63E-06 4.96E-07 3.72E-07 2.81E-07 4.90E-06 3.26E-07 2.56E-08 1.19E-08 5.55E-10 8.00E-09 2.98E-11 1.42E-08 933 COA 114' Floor 6.04E-04 2.22E-04 2.98E-08 7.49E-07 1.78E-08 3.17E-05 9.67E-06 7.25E-06 5.47E-06 9.55E-05 6.34E-06 4.98E-07 2.32E-07 1.08E-08 1.56E-07 5.80E-10 2.77E-07 928 COA 114' North Wall 1.21E-06 4.46E-07 6.00E-11 1.51E-09 3.57E-11 6.38E-08 1.94E-08 1.46E-08 1.10E-08 1.92E-07 1.28E-08 1.00E-09 4.66E-10 2.17E-11 3.13E-10 1.17E-12 5.56E-10 929 COA 114' South Wall 2.55E-04 9.37E-05 1.26E-08 3.17E-07 7.51E-09 1.34E-05 4.08E-06 3.06E-06 2.31E-06 4.03E-05 2.68E-06 2.10E-07 9.80E-08 4.57E-09 6.59E-08 2.45E-10 1.17E-07 931 COA 114' West Wall 1.49E-04 5.45E-05 7.34E-09 1.84E-07 4.37E-09 7.80E-06 2.38E-06 1.78E-06 1.34E-06 2.35E-05 1.56E-06 1.22E-07 5.70E-08 2.66E-09 3.83E-08 1.43E-10 6.80E-08 1695 COA 114' Pipe 13CW142 2.11E-09 7.73E-10 1.04E-13 2.61E-12 6.19E-14 1.11E-10 3.37E-11 2.53E-11 1.91E-11 3.33E-10 2.21E-11 1.74E-12 8.09E-13 3.77E-14 5.44E-13 2.02E-15 9.65E-13 1659 COA 114' Pipe 13S133 6.41E-13 2.35E-13 3.17E-17 7.95E-16 1.88E-17 3.36E-14 1.03E-14 7.69E-15 5.80E-15 1.01E-13 6.73E-15 5.28E-16 2.46E-16 1.15E-17 1.65E-16 6.15E-19 2.93E-16 1660 COA 114' Pipe 13S134 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 1696 COA 114' Pipe 13S134 1.05E-08 3.87E-09 5.20E-13 1.31E-11 3.10E-13 5.53E-10 1.69E-10 1.26E-10 9.53E-11 1.66E-09 1.11E-10 8.68E-12 4.05E-12 1.89E-13 2.72E-12 1.01E-14 4.82E-12 1661 COA 114' Pipe 13S139 6.41E-13 2.35E-13 3.17E-17 7.95E-16 1.88E-17 3.36E-14 1.03E-14 7.69E-15 5.80E-15 1.01E-13 6.73E-15 5.28E-16 2.46E-16 1.15E-17 1.65E-16 6.15E-19 2.93E-16 1648 COA 114' Pipe 13S151 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 2911 COA 114' Pipe 13S151 2.41E-06 8.83E-07 1.19E-10 2.98E-09 7.08E-11 1.26E-07 3.85E-08 2.89E-08 2.18E-08 3.80E-07 2.53E-08 1.98E-09 9.24E-10 4.31E-11 6.21E-10 2.31E-12 1.10E-09 1649 COA 114' Pipe 13UA148 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 2912 COA 114' Pipe 13UA148 1.92E-06 7.06E-07 9.50E-11 2.39E-09 5.66E-11 1.01E-07 3.08E-08 2.31E-08 1.74E-08 3.04E-07 2.02E-08 1.59E-09 7.39E-10 3.44E-11 4.96E-10 1.85E-12 8.81E-10 1650 COA 114' Pipe 13UA156 1.60E-12 5.88E-13 7.91E-17 1.99E-15 4.71E-17 8.41E-14 2.56E-14 1.92E-14 1.45E-14 2.53E-13 1.68E-14 1.32E-15 6.15E-16 2.87E-17 4.13E-16 1.54E-18 7.34E-16 2913 COA 114' Pipe 13UA156 1.28E-06 4.70E-07 6.32E-11 1.59E-09 3.76E-11 6.72E-08 2.05E-08 1.54E-08 1.16E-08 2.02E-07 1.34E-08 1.05E-09 4.92E-10 2.29E-11 3.30E-10 1.23E-12 5.86E-10 1651 COA 114' Pipe 14CH2178 1.49E-12 5.45E-13 7.34E-17 1.84E-15 4.37E-17 7.80E-14 2.38E-14 1.78E-14 1.34E-14 2.35E-13 1.56E-14 1.22E-15 5.70E-16 2.66E-17 3.83E-16 1.43E-18 6.80E-16 2914 COA 114' Pipe 14CH2178 2.41E-06 8.83E-07 1.19E-10 2.98E-09 7.08E-11 1.26E-07 3.85E-08 2.89E-08 2.18E-08 3.80E-07 2.53E-08 1.98E-09 9.24E-10 4.31E-11 6.21E-10 2.31E-12 1.10E-09 1678 COA 114' Pipe 14CH83 2.62E-12 9.61E-13 1.29E-16 3.25E-15 7.70E-17 1.37E-13 4.19E-14 3.14E-14 2.37E-14 4.14E-13 2.75E-14 2.16E-15 1.01E-15 4.69E-17 6.76E-16 2.51E-18 1.20E-15 1662 COA 114' Pipe 15DW312 6.41E-13 2.35E-13 3.17E-17 7.95E-16 1.88E-17 3.36E-14 1.03E-14 7.69E-15 5.80E-15 1.01E-13 6.73E-15 5.28E-16 2.46E-16 1.15E-17 1.65E-16 6.15E-19 2.93E-16 1667 COA 114' Pipe 15J1298 6.61E-13 2.43E-13 3.27E-17 8.20E-16 1.94E-17 3.47E-14 1.06E-14 7.94E-15 5.98E-15 1.04E-13 6.94E-15 5.45E-16 2.54E-16 1.18E-17 1.71E-16 6.35E-19 3.03E-16 1663 COA 114' Pipe 15J1300 6.41E-13 2.35E-13 3.17E-17 7.95E-16 1.88E-17 3.36E-14 1.03E-14 7.69E-15 5.80E-15 1.01E-13 6.73E-15 5.28E-16 2.46E-16 1.15E-17 1.65E-16 6.15E-19 2.93E-16 1668 COA 114' Pipe 15J1315 6.61E-13 2.43E-13 3.27E-17 8.20E-16 1.94E-17 3.47E-14 1.06E-14 7.94E-15 5.98E-15 1.04E-13 6.94E-15 5.45E-16 2.54E-16 1.18E-17 1.71E-16 6.35E-19 3.03E-16 1654 COA 114' Pipe 15S720 3.01E-09 1.10E-09 1.49E-13 3.73E-12 8.84E-14 1.58E-10 4.81E-11 3.61E-11 2.72E-11 4.75E-10 3.16E-11 2.48E-12 1.15E-12 5.38E-14 7.76E-13 2.89E-15 1.38E-12 2920 COA 114' Pipe 15S720 3.61E-08 1.32E-08 1.78E-12 4.47E-11 1.06E-12 1.89E-09 5.77E-10 4.33E-10 3.26E-10 5.70E-09 3.79E-10 2.97E-11 1.38E-11 6.46E-13 9.30E-12 3.46E-14 1.65E-11 1672 COA 114' Pipe 15S724 4.01E-08 1.47E-08 1.98E-12 4.97E-11 1.18E-12 2.10E-09 6.41E-10 4.81E-10 3.63E-10 6.33E-09 4.21E-10 3.30E-11 1.54E-11 7.18E-13 1.03E-11 3.85E-14 1.84E-11 1666 COA 114' Pipe 15S725 3.50E-08 1.29E-08 1.73E-12 4.34E-11 1.03E-12 1.84E-09 5.61E-10 4.20E-10 3.17E-10 5.54E-09 3.68E-10 2.89E-11 1.35E-11 6.27E-13 9.04E-12 3.36E-14 1.60E-11 1652 COA 114' Pipe 15UA702 1.60E-12 5.88E-13 7.91E-17 1.99E-15 4.71E-17 8.41E-14 2.56E-14 1.92E-14 1.45E-14 2.53E-13 1.68E-14 1.32E-15 6.15E-16 2.87E-17 4.13E-16 1.54E-18 7.34E-16 2923 COA 114' Pipe 15UA702 3.85E-06 1.41E-06 1.90E-10 4.77E-09 1.13E-10 2.02E-07 6.16E-08 4.62E-08 3.48E-08 6.08E-07 4.04E-08 3.17E-09 1.48E-09 6.89E-11 9.93E-10 3.69E-12 1.76E-09 1697 COA 114' Pipe 3S86 8.41E-09 3.09E-09 4.16E-13 1.04E-11 2.47E-13 4.42E-10 1.35E-10 1.01E-10 7.61E-11 1.33E-09 8.83E-11 6.93E-12 3.23E-12 1.51E-13 2.17E-12 8.08E-15 3.85E-12 1679 COA 114' Pipe 4CW460 1.40E-12 5.15E-13 6.94E-17 1.74E-15 4.13E-17 7.37E-14 2.25E-14 1.69E-14 1.27E-14 2.22E-13 1.47E-14 1.16E-15 5.39E-16 2.51E-17 3.62E-16 1.35E-18 6.43E-16 1680 COA 114' Pipe 4CW461 1.40E-12 5.15E-13 6.94E-17 1.74E-15 4.13E-17 7.37E-14 2.25E-14 1.69E-14 1.27E-14 2.22E-13 1.47E-14 1.16E-15 5.39E-16 2.51E-17 3.62E-16 1.35E-18 6.43E-16 1641 COA 114' Pipe 4P622C 1.00E-13 3.68E-14 4.95E-18 1.24E-16 2.95E-18 5.26E-15 1.60E-15 1.20E-15 9.07E-16 1.58E-14 1.05E-15 8.26E-17 3.85E-17 1.79E-18 2.59E-17 9.62E-20 4.59E-17 2931 COA 114' Pipe 4P622C 5.95E-09 2.18E-09 2.94E-13 7.37E-12 1.75E-13 3.12E-10 9.52E-11 7.14E-11 5.38E-11 9.40E-10 6.24E-11 4.90E-12 2.28E-12 1.06E-13 1.53E-12 5.71E-15 2.72E-12
WVDP-606 Rev. 1 Page 15 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1685 COA 114' Pipe 4S464 3.76E-12 1.38E-12 1.86E-16 4.66E-15 1.11E-16 1.97E-13 6.02E-14 4.51E-14 3.40E-14 5.94E-13 3.95E-14 3.10E-15 1.44E-15 6.73E-17 9.70E-16 3.61E-18 1.72E-15 1686 COA 114' Pipe 4S465 3.76E-12 1.38E-12 1.86E-16 4.66E-15 1.11E-16 1.97E-13 6.02E-14 4.51E-14 3.40E-14 5.94E-13 3.95E-14 3.10E-15 1.44E-15 6.73E-17 9.70E-16 3.61E-18 1.72E-15 1687 COA 114' Pipe 4S466 3.76E-12 1.38E-12 1.86E-16 4.66E-15 1.11E-16 1.97E-13 6.02E-14 4.51E-14 3.40E-14 5.94E-13 3.95E-14 3.10E-15 1.44E-15 6.73E-17 9.70E-16 3.61E-18 1.72E-15 1681 COA 114' Pipe 4S470 3.50E-12 1.29E-12 1.73E-16 4.34E-15 1.03E-16 1.84E-13 5.61E-14 4.20E-14 3.17E-14 5.54E-13 3.68E-14 2.89E-15 1.35E-15 6.27E-17 9.04E-16 3.36E-18 1.60E-15 1682 COA 114' Pipe 4S471 3.50E-12 1.29E-12 1.73E-16 4.34E-15 1.03E-16 1.84E-13 5.61E-14 4.20E-14 3.17E-14 5.54E-13 3.68E-14 2.89E-15 1.35E-15 6.27E-17 9.04E-16 3.36E-18 1.60E-15 1642 COA 114' Pipe 4S496 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2937 COA 114' Pipe 4S496 1.47E-07 5.40E-08 7.26E-12 1.82E-10 4.32E-12 7.72E-09 2.35E-09 1.76E-09 1.33E-09 2.32E-08 1.54E-09 1.21E-10 5.65E-11 2.63E-12 3.79E-11 1.41E-13 6.73E-11 1643 COA 114' Pipe 4S619 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2938 COA 114' Pipe 4S619 4.69E-07 1.72E-07 2.32E-11 5.81E-10 1.38E-11 2.46E-08 7.50E-09 5.63E-09 4.24E-09 7.41E-08 4.92E-09 3.86E-10 1.80E-10 8.39E-12 1.21E-10 4.50E-13 2.15E-10 1644 COA 114' Pipe 4S620 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2939 COA 114' Pipe 4S620 1.95E-07 7.14E-08 9.61E-12 2.41E-10 5.72E-12 1.02E-08 3.11E-09 2.34E-09 1.76E-09 3.07E-08 2.04E-09 1.60E-10 7.47E-11 3.48E-12 5.02E-11 1.87E-13 8.91E-11 1645 COA 114' Pipe 4S621 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2940 COA 114' Pipe 4S621 2.41E-07 8.86E-08 1.19E-11 2.99E-10 7.10E-12 1.27E-08 3.86E-09 2.90E-09 2.18E-09 3.81E-08 2.53E-09 1.99E-10 9.27E-11 4.32E-12 6.23E-11 2.32E-13 1.11E-10 1646 COA 114' Pipe 4S626 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2941 COA 114' Pipe 4S626 2.41E-08 8.86E-09 1.19E-12 2.99E-11 7.10E-13 1.27E-09 3.86E-10 2.90E-10 2.18E-10 3.81E-09 2.53E-10 1.99E-11 9.27E-12 4.32E-13 6.23E-12 2.32E-14 1.11E-11 1669 COA 114' Pipe 4S78 7.21E-09 2.65E-09 3.56E-13 8.94E-12 2.12E-13 3.79E-10 1.15E-10 8.66E-11 6.53E-11 1.14E-09 7.57E-11 5.94E-12 2.77E-12 1.29E-13 1.86E-12 6.92E-15 3.30E-12 1674 COA 114' Pipe 4S84 1.43E-12 5.26E-13 7.08E-17 1.78E-15 4.22E-17 7.53E-14 2.29E-14 1.72E-14 1.30E-14 2.27E-13 1.51E-14 1.18E-15 5.51E-16 2.57E-17 3.70E-16 1.38E-18 6.57E-16 1675 COA 114' Pipe 4S85 1.43E-12 5.26E-13 7.08E-17 1.78E-15 4.22E-17 7.53E-14 2.29E-14 1.72E-14 1.30E-14 2.27E-13 1.51E-14 1.18E-15 5.51E-16 2.57E-17 3.70E-16 1.38E-18 6.57E-16 1676 COA 114' Pipe 4S90 8.85E-09 3.25E-09 4.37E-13 1.10E-11 2.60E-13 4.65E-10 1.42E-10 1.06E-10 8.01E-11 1.40E-09 9.29E-11 7.29E-12 3.40E-12 1.58E-13 2.28E-12 8.50E-15 4.05E-12 1688 COA 114' Pipe 4UA468 3.76E-12 1.38E-12 1.86E-16 4.66E-15 1.11E-16 1.97E-13 6.02E-14 4.51E-14 3.40E-14 5.94E-13 3.95E-14 3.10E-15 1.44E-15 6.73E-17 9.70E-16 3.61E-18 1.72E-15 1664 COA 114' Pipe 4UA502 6.41E-13 2.35E-13 3.17E-17 7.95E-16 1.88E-17 3.36E-14 1.03E-14 7.69E-15 5.80E-15 1.01E-13 6.73E-15 5.28E-16 2.46E-16 1.15E-17 1.65E-16 6.15E-19 2.93E-16 1670 COA 114' Pipe 4UA82 6.61E-13 2.43E-13 3.27E-17 8.20E-16 1.94E-17 3.47E-14 1.06E-14 7.94E-15 5.98E-15 1.04E-13 6.94E-15 5.45E-16 2.54E-16 1.18E-17 1.71E-16 6.35E-19 3.03E-16 1671 COA 114' Pipe 4UA83 6.61E-13 2.43E-13 3.27E-17 8.20E-16 1.94E-17 3.47E-14 1.06E-14 7.94E-15 5.98E-15 1.04E-13 6.94E-15 5.45E-16 2.54E-16 1.18E-17 1.71E-16 6.35E-19 3.03E-16 1655 COA 114' Pipe 5CW189 9.00E-07 3.30E-07 4.44E-11 1.12E-09 2.65E-11 4.72E-08 1.44E-08 1.08E-08 8.14E-09 1.42E-07 9.45E-09 7.41E-10 3.46E-10 1.61E-11 2.32E-10 8.64E-13 4.12E-10 2950 COA 114' Pipe 5CW189 1.08E-05 3.97E-06 5.35E-10 1.34E-08 3.18E-10 5.68E-07 1.73E-07 1.30E-07 9.80E-08 1.71E-06 1.14E-07 8.92E-09 4.16E-09 1.94E-10 2.79E-09 1.04E-11 4.96E-09 1647 COA 114' Pipe 6-71-136 1.54E-08 5.66E-09 7.63E-13 1.91E-11 4.54E-13 8.10E-10 2.47E-10 1.85E-10 1.40E-10 2.44E-09 1.62E-10 1.27E-11 5.93E-12 2.76E-13 3.98E-12 1.48E-14 7.07E-12 2951 COA 114' Pipe 6-71-136 1.85E-07 6.79E-08 9.14E-12 2.29E-10 5.44E-12 9.72E-09 2.96E-09 2.22E-09 1.67E-09 2.92E-08 1.94E-09 1.53E-10 7.11E-11 3.31E-12 4.77E-11 1.78E-13 8.48E-11 1656 COA 114' Pipe 7CH22 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2952 COA 114' Pipe 7CH22 3.01E-06 1.10E-06 1.49E-10 3.73E-09 8.84E-11 1.58E-07 4.81E-08 3.61E-08 2.72E-08 4.75E-07 3.16E-08 2.48E-09 1.15E-09 5.38E-11 7.76E-10 2.89E-12 1.38E-09 1694 COA 114' Pipe 7CW101 1.95E-08 7.14E-09 9.61E-13 2.41E-11 5.72E-13 1.02E-09 3.11E-10 2.34E-10 1.76E-10 3.07E-09 2.04E-10 1.60E-11 7.47E-12 3.48E-13 5.02E-12 1.87E-14 8.91E-12 1665 COA 114' Pipe 7DW117 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 1693 COA 114' Pipe 7J140b 4.90E-07 1.80E-07 2.42E-11 6.08E-10 1.44E-11 2.57E-08 7.84E-09 5.88E-09 4.44E-09 7.74E-08 5.15E-09 4.04E-10 1.88E-10 8.77E-12 1.26E-10 4.71E-13 2.24E-10 2954 COA 114' Pipe 7J140b 1.35E-07 4.94E-08 6.65E-12 1.67E-10 3.96E-12 7.07E-09 2.15E-09 1.62E-09 1.22E-09 2.13E-08 1.41E-09 1.11E-10 5.17E-11 2.41E-12 3.47E-11 1.29E-13 6.16E-11 1657 COA 114' Pipe 7J21A 4.18E-13 1.53E-13 2.06E-17 5.18E-16 1.23E-17 2.19E-14 6.68E-15 5.01E-15 3.78E-15 6.60E-14 4.39E-15 3.44E-16 1.60E-16 7.48E-18 1.08E-16 4.01E-19 1.91E-16 2955 COA 114' Pipe 7J21A 1.00E-06 3.68E-07 4.95E-11 1.24E-09 2.95E-11 5.26E-08 1.60E-08 1.20E-08 9.07E-09 1.58E-07 1.05E-08 8.26E-10 3.85E-10 1.79E-11 2.59E-10 9.62E-13 4.59E-10
WVDP-606 Rev. 1 Page 16 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1689 COA 114' Pipe 7J56A 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 1690 COA 114' Pipe 7J56B 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 1691 COA 114' Pipe 7J56C 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 1677 COA 114' Pipe 7S12 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 1673 COA 114' Pipe 7S144 2.19E-09 8.03E-10 1.08E-13 2.71E-12 6.43E-14 1.15E-10 3.50E-11 2.62E-11 1.98E-11 3.46E-10 2.30E-11 1.80E-12 8.40E-13 3.92E-14 5.64E-13 2.10E-15 1.00E-12 1653 COA 114' Pipe 7S24 3.61E-12 1.32E-12 1.78E-16 4.47E-15 1.06E-16 1.89E-13 5.77E-14 4.33E-14 3.26E-14 5.70E-13 3.79E-14 2.97E-15 1.38E-15 6.46E-17 9.30E-16 3.46E-18 1.65E-15 2961 COA 114' Pipe 7S24 4.90E-07 1.80E-07 2.42E-11 6.08E-10 1.44E-11 2.57E-08 7.84E-09 5.88E-09 4.44E-09 7.74E-08 5.15E-09 4.04E-10 1.88E-10 8.77E-12 1.26E-10 4.71E-13 2.24E-10 1683 COA 114' Pipe 7S58 3.50E-12 1.29E-12 1.73E-16 4.34E-15 1.03E-16 1.84E-13 5.61E-14 4.20E-14 3.17E-14 5.54E-13 3.68E-14 2.89E-15 1.35E-15 6.27E-17 9.04E-16 3.36E-18 1.60E-15 1692 COA 114' Pipe 7S61 3.76E-12 1.38E-12 1.86E-16 4.66E-15 1.11E-16 1.97E-13 6.02E-14 4.51E-14 3.40E-14 5.94E-13 3.95E-14 3.10E-15 1.44E-15 6.73E-17 9.70E-16 3.61E-18 1.72E-15 1658 COA 114' Pipe 7S9 1.50E-12 5.50E-13 7.41E-17 1.86E-15 4.41E-17 7.87E-14 2.40E-14 1.80E-14 1.36E-14 2.37E-13 1.57E-14 1.24E-15 5.76E-16 2.68E-17 3.87E-16 1.44E-18 6.87E-16 2964 COA 114' Pipe 7S9 3.12E-08 1.15E-08 1.54E-12 3.87E-11 9.18E-13 1.64E-09 5.00E-10 3.75E-10 2.83E-10 4.94E-09 3.28E-10 2.57E-11 1.20E-11 5.59E-13 8.06E-12 3.00E-14 1.43E-11 1684 COA 114' Pipe 7UA52 1.40E-12 5.15E-13 6.94E-17 1.74E-15 4.13E-17 7.37E-14 2.25E-14 1.69E-14 1.27E-14 2.22E-13 1.47E-14 1.16E-15 5.39E-16 2.51E-17 3.62E-16 1.35E-18 6.43E-16 1161 CPC Ceiling 1.90E-01 5.11E-01 2.29E-05 5.11E-04 2.17E-06 2.74E-02 9.58E-03 7.07E-03 5.35E-03 8.34E-02 6.72E-04 2.63E-04 1.25E-04 8.74E-07 9.79E-06 1.83E-07 8.72E-05 1159 CPC E Wall 6.36E-01 1.70E+00 7.63E-05 1.70E-03 7.25E-06 9.16E-02 3.20E-02 2.36E-02 1.79E-02 2.79E-01 2.24E-03 8.78E-04 4.16E-04 2.92E-06 3.27E-05 6.10E-07 2.91E-04 1157 CPC N Wall 1.63E-02 4.36E-02 1.95E-06 4.36E-05 1.85E-07 2.34E-03 8.17E-04 6.03E-04 4.57E-04 7.12E-03 5.74E-05 2.24E-05 1.06E-05 7.46E-08 8.35E-07 1.56E-08 7.44E-06 1158 CPC S Wall 1.69E-01 4.53E-01 2.03E-05 4.53E-04 1.93E-06 2.43E-02 8.50E-03 6.27E-03 4.75E-03 7.40E-02 5.97E-04 2.33E-04 1.11E-04 7.76E-07 8.69E-06 1.62E-07 7.74E-05 1160 CPC W Wall 6.63E-02 1.78E-01 7.96E-06 1.78E-04 7.56E-07 9.55E-03 3.34E-03 2.46E-03 1.86E-03 2.90E-02 2.34E-04 9.15E-05 4.34E-05 3.04E-07 3.41E-06 6.37E-08 3.04E-05 1945 CPC Penthouse Ceiling 3.91E-04 1.05E-03 4.70E-08 1.05E-06 4.46E-09 5.63E-05 1.97E-05 1.45E-05 1.10E-05 1.71E-04 1.38E-06 5.40E-07 2.56E-07 1.80E-09 2.01E-08 3.76E-10 1.79E-07 1943 CPC Penthouse E Wall 3.15E-04 8.45E-04 3.78E-08 8.45E-07 3.59E-09 4.54E-05 1.59E-05 1.17E-05 8.86E-06 1.38E-04 1.11E-06 4.35E-07 2.06E-07 1.45E-09 1.62E-08 3.03E-10 1.44E-07 1946 CPC Penthouse Floor 1.66E-03 4.44E-03 1.99E-07 4.44E-06 1.89E-08 2.39E-04 8.34E-05 6.15E-05 4.66E-05 7.26E-04 5.85E-06 2.29E-06 1.09E-06 7.61E-09 8.52E-08 1.59E-09 7.59E-07 1941 CPC Penthouse N Wall 6.71E-04 1.80E-03 8.05E-08 1.80E-06 7.65E-09 9.67E-05 3.38E-05 2.49E-05 1.89E-05 2.94E-04 2.37E-06 9.26E-07 4.40E-07 3.08E-09 3.45E-08 6.44E-10 3.07E-07 1942 CPC Penthouse S Wall 4.57E-04 1.22E-03 5.48E-08 1.22E-06 5.20E-09 6.57E-05 2.30E-05 1.69E-05 1.28E-05 2.00E-04 1.61E-06 6.30E-07 2.99E-07 2.10E-09 2.35E-08 4.38E-10 2.09E-07 1944 CPC Penthouse W Wall 1.65E-04 4.43E-04 1.98E-08 4.43E-07 1.88E-09 2.38E-05 8.31E-06 6.13E-06 4.64E-06 7.24E-05 5.83E-07 2.28E-07 1.08E-07 7.58E-10 8.49E-09 1.59E-10 7.57E-08 921 CR 144' Ceiling 3.56E-04 1.30E-04 1.76E-08 4.41E-07 1.05E-08 1.87E-05 5.69E-06 4.27E-06 3.22E-06 5.62E-05 3.73E-06 2.93E-07 1.37E-07 6.36E-09 9.17E-08 3.41E-10 1.63E-07 922 CR 144' Ceiling 8.05E-05 2.95E-05 3.98E-09 9.98E-08 2.37E-09 4.22E-06 1.29E-06 9.66E-07 7.28E-07 1.27E-05 8.45E-07 6.63E-08 3.09E-08 1.44E-09 2.08E-08 7.72E-11 3.69E-08 923 CR 144' Ceiling 4.76E-05 1.75E-05 2.35E-09 5.91E-08 1.40E-09 2.50E-06 7.62E-07 5.71E-07 4.31E-07 7.52E-06 5.00E-07 3.92E-08 1.83E-08 8.52E-10 1.23E-08 4.57E-11 2.18E-08 693 CR 144' E Wall 3.07E-06 1.13E-06 1.52E-10 3.81E-09 9.03E-11 1.61E-07 4.92E-08 3.69E-08 2.78E-08 4.85E-07 3.23E-08 2.53E-09 1.18E-09 5.50E-11 7.93E-10 2.95E-12 1.41E-09 705 CR 144' E Wall 9.36E-06 3.44E-06 4.63E-10 1.16E-08 2.75E-10 4.92E-07 1.50E-07 1.12E-07 8.47E-08 1.48E-06 9.83E-08 7.72E-09 3.60E-09 1.68E-10 2.42E-09 8.99E-12 4.29E-09 710 CR 144' E Wall 1.05E-05 3.87E-06 5.20E-10 1.31E-08 3.10E-10 5.53E-07 1.69E-07 1.26E-07 9.53E-08 1.66E-06 1.11E-07 8.68E-09 4.05E-09 1.89E-10 2.72E-09 1.01E-11 4.82E-09 691 CR 144' Floor 2.55E-06 9.37E-07 1.26E-10 3.17E-09 7.51E-11 1.34E-07 4.08E-08 3.06E-08 2.31E-08 4.03E-07 2.68E-08 2.10E-09 9.80E-10 4.57E-11 6.59E-10 2.45E-12 1.17E-09 703 CR 144' Floor 6.94E-07 2.55E-07 3.43E-11 8.61E-10 2.04E-11 3.64E-08 1.11E-08 8.33E-09 6.28E-09 1.10E-07 7.29E-09 5.72E-10 2.67E-10 1.24E-11 1.79E-10 6.66E-13 3.18E-10 708 CR 144' Floor 6.34E-05 2.32E-05 3.13E-09 7.86E-08 1.86E-09 3.33E-06 1.01E-06 7.60E-07 5.73E-07 1.00E-05 6.65E-07 5.22E-08 2.43E-08 1.13E-09 1.63E-08 6.08E-11 2.90E-08 707 CR 144' N Wall 9.51E-06 3.49E-06 4.70E-10 1.18E-08 2.80E-10 4.99E-07 1.52E-07 1.14E-07 8.61E-08 1.50E-06 9.99E-08 7.84E-09 3.65E-09 1.70E-10 2.45E-09 9.13E-12 4.36E-09 712 CR 144' N Wall 1.89E-04 6.95E-05 9.36E-09 2.35E-07 5.57E-09 9.95E-06 3.03E-06 2.27E-06 1.71E-06 2.99E-05 1.99E-06 1.56E-07 7.28E-08 3.39E-09 4.89E-08 1.82E-10 8.68E-08 733 CR 144' N Wall 7.46E-06 2.74E-06 3.69E-10 9.25E-09 2.19E-10 3.92E-07 1.19E-07 8.95E-08 6.75E-08 1.18E-06 7.83E-08 6.15E-09 2.87E-09 1.34E-10 1.93E-09 7.16E-12 3.42E-09
WVDP-606 Rev. 1 Page 17 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 697 CR 144' S Wall 1.13E-06 4.16E-07 5.60E-11 1.41E-09 3.33E-11 5.95E-08 1.81E-08 1.36E-08 1.03E-08 1.79E-07 1.19E-08 9.34E-10 4.35E-10 2.03E-11 2.93E-10 1.09E-12 5.19E-10 711 CR 144' S Wall 2.41E-05 8.86E-06 1.19E-09 2.99E-08 7.10E-10 1.27E-06 3.86E-07 2.90E-07 2.18E-07 3.81E-06 2.53E-07 1.99E-08 9.27E-09 4.32E-10 6.23E-09 2.32E-11 1.11E-08 722 CR 144' S Wall 2.87E-08 1.05E-08 1.42E-12 3.56E-11 8.43E-13 1.51E-09 4.59E-10 3.44E-10 2.60E-10 4.53E-09 3.01E-10 2.36E-11 1.10E-11 5.13E-13 7.40E-12 2.75E-14 1.31E-11 692 CR 144' W Wall 8.49E-05 3.11E-05 4.19E-09 1.05E-07 2.49E-09 4.46E-06 1.36E-06 1.02E-06 7.68E-07 1.34E-05 8.91E-07 6.99E-08 3.26E-08 1.52E-09 2.19E-08 8.15E-11 3.89E-08 709 CR 144' W Wall 4.54E-05 1.67E-05 2.24E-09 5.63E-08 1.34E-09 2.38E-06 7.27E-07 5.45E-07 4.11E-07 7.18E-06 4.77E-07 3.74E-08 1.74E-08 8.13E-10 1.17E-08 4.36E-11 2.08E-08 714 CR 144' W Wall 1.43E-04 5.26E-05 7.08E-09 1.78E-07 4.22E-09 7.53E-06 2.29E-06 1.72E-06 1.30E-06 2.27E-05 1.51E-06 1.18E-07 5.51E-08 2.57E-09 3.70E-08 1.38E-10 6.57E-08 864 CTS LAB 131' Ceiling 1.10E-05 4.05E-06 5.46E-10 1.37E-08 3.25E-10 5.80E-07 1.77E-07 1.33E-07 1.00E-07 1.75E-06 1.16E-07 9.10E-09 4.24E-09 1.98E-10 2.85E-09 1.06E-11 5.06E-09 862 CTS LAB 131' E Wall 2.83E-06 1.04E-06 1.40E-10 3.51E-09 8.32E-11 1.49E-07 4.53E-08 3.40E-08 2.56E-08 4.47E-07 2.97E-08 2.33E-09 1.09E-09 5.07E-11 7.30E-10 2.72E-12 1.30E-09 865 CTS LAB 131' Floor 4.35E-07 1.59E-07 2.15E-11 5.39E-10 1.28E-11 2.28E-08 6.95E-09 5.21E-09 3.93E-09 6.87E-08 4.56E-09 3.58E-10 1.67E-10 7.78E-12 1.12E-10 4.17E-13 1.99E-10 1178 CTS LAB 131' Hood #10 3.56E-07 1.31E-07 1.76E-11 4.42E-10 1.05E-11 1.87E-08 5.70E-09 4.28E-09 3.22E-09 5.63E-08 3.74E-09 2.94E-10 1.37E-10 6.38E-12 9.19E-11 3.42E-13 1.63E-10 1179 CTS LAB 131' Hood #11 2.98E-07 1.10E-07 1.47E-11 3.70E-10 8.77E-12 1.57E-08 4.78E-09 3.58E-09 2.70E-09 4.72E-08 3.13E-09 2.46E-10 1.15E-10 5.34E-12 7.70E-11 2.87E-13 1.37E-10 1180 CTS LAB 131' Hood #12 2.27E-07 8.32E-08 1.12E-11 2.81E-10 6.67E-12 1.19E-08 3.63E-09 2.72E-09 2.05E-09 3.58E-08 2.38E-09 1.87E-10 8.71E-11 4.06E-12 5.85E-11 2.18E-13 1.04E-10 1181 CTS LAB 131' Hood #13 3.83E-06 1.41E-06 1.89E-10 4.75E-09 1.13E-10 2.01E-07 6.13E-08 4.60E-08 3.47E-08 6.06E-07 4.02E-08 3.16E-09 1.47E-09 6.86E-11 9.89E-10 3.68E-12 1.76E-09 1182 CTS LAB 131' Hood #14 2.85E-06 1.04E-06 1.41E-10 3.53E-09 8.37E-11 1.49E-07 4.55E-08 3.41E-08 2.58E-08 4.50E-07 2.99E-08 2.34E-09 1.09E-09 5.09E-11 7.34E-10 2.73E-12 1.30E-09 1177 CTS LAB 131' Hood #9 4.76E-07 1.75E-07 2.35E-11 5.91E-10 1.40E-11 2.50E-08 7.62E-09 5.71E-09 4.31E-09 7.52E-08 5.00E-09 3.92E-10 1.83E-10 8.52E-12 1.23E-10 4.57E-13 2.18E-10 860 CTS LAB 131' N Wall 6.53E-06 2.39E-06 3.22E-10 8.09E-09 1.92E-10 3.43E-07 1.04E-07 7.83E-08 5.91E-08 1.03E-06 6.85E-08 5.38E-09 2.51E-09 1.17E-10 1.68E-09 6.26E-12 2.99E-09 861 CTS LAB 131' S Wall 6.41E-07 2.35E-07 3.17E-11 7.95E-10 1.88E-11 3.36E-08 1.03E-08 7.69E-09 5.80E-09 1.01E-07 6.73E-09 5.28E-10 2.46E-10 1.15E-11 1.65E-10 6.15E-13 2.93E-10 863 CTS LAB 131' W Wall 2.83E-07 1.04E-07 1.40E-11 3.51E-10 8.32E-12 1.49E-08 4.53E-09 3.40E-09 2.56E-09 4.47E-08 2.97E-09 2.33E-10 1.09E-10 5.07E-12 7.30E-11 2.72E-13 1.30E-10 1934 E. Stairs Ceiling 4.21E-06 1.54E-06 2.08E-10 5.22E-09 1.24E-10 2.21E-07 6.73E-08 5.05E-08 3.81E-08 6.65E-07 4.42E-08 3.47E-09 1.62E-09 7.53E-11 1.09E-09 4.04E-12 1.93E-09 1931 E. Stairs East Wall 2.38E-05 8.75E-06 1.18E-09 2.96E-08 7.01E-10 1.25E-06 3.82E-07 2.86E-07 2.16E-07 3.77E-06 2.50E-07 1.97E-08 9.16E-09 4.27E-10 6.15E-09 2.29E-11 1.09E-08 1933 E. Stairs Landing 5.01E-06 1.84E-06 2.48E-10 6.21E-09 1.47E-10 2.63E-07 8.02E-08 6.01E-08 4.53E-08 7.92E-07 5.26E-08 4.13E-09 1.92E-09 8.97E-11 1.29E-09 4.81E-12 2.30E-09 1929 E. Stairs North Wall 1.38E-05 5.05E-06 6.79E-10 1.71E-08 4.04E-10 7.22E-07 2.20E-07 1.65E-07 1.24E-07 2.17E-06 1.44E-07 1.13E-08 5.28E-09 2.46E-10 3.55E-09 1.32E-11 6.30E-09 1930 E. Stairs South Wall 1.55E-05 5.69E-06 7.66E-10 1.92E-08 4.56E-10 8.14E-07 2.48E-07 1.86E-07 1.40E-07 2.45E-06 1.63E-07 1.28E-08 5.96E-09 2.78E-10 4.00E-09 1.49E-11 7.10E-09 1932 E. Stairs West Wall 2.45E-05 8.99E-06 1.21E-09 3.04E-08 7.20E-10 1.29E-06 3.92E-07 2.94E-07 2.22E-07 3.87E-06 2.57E-07 2.02E-08 9.41E-09 4.39E-10 6.32E-09 2.35E-11 1.12E-08 625 EDR Ceiling 1.61E-03 4.31E-03 1.93E-07 4.31E-06 1.83E-08 2.32E-04 8.09E-05 5.97E-05 4.50E-05 7.05E-04 5.68E-06 2.22E-06 1.06E-06 7.40E-09 8.27E-08 1.54E-09 7.37E-07 623 EDR E Wall 3.18E-03 8.52E-03 3.82E-07 8.52E-06 3.62E-08 4.58E-04 1.60E-04 1.18E-04 8.90E-05 1.39E-03 1.12E-05 4.39E-06 2.09E-06 1.46E-08 1.63E-07 3.05E-09 1.46E-06 626 EDR N Wall 2.55E-04 6.85E-04 3.07E-08 6.85E-07 2.91E-09 3.68E-05 1.28E-05 9.48E-06 7.15E-06 1.12E-04 9.02E-07 3.53E-07 1.68E-07 1.18E-09 1.31E-08 2.45E-10 1.17E-07 622 EDR S Wall 2.33E-04 6.25E-04 2.80E-08 6.25E-07 2.66E-09 3.36E-05 1.17E-05 8.65E-06 6.53E-06 1.02E-04 8.23E-07 3.22E-07 1.53E-07 1.07E-09 1.20E-08 2.24E-10 1.07E-07 624 EDR W Wall 1.49E-04 4.00E-04 1.79E-08 4.00E-07 1.70E-09 2.15E-05 7.50E-06 5.53E-06 4.18E-06 6.53E-05 5.27E-07 2.06E-07 9.79E-08 6.86E-10 7.67E-09 1.43E-10 6.83E-08 949 EDRVA 114' Ceiling 9.66E-07 3.54E-07 4.77E-11 1.20E-09 2.84E-11 5.07E-08 1.54E-08 1.16E-08 8.74E-09 1.53E-07 1.01E-08 7.96E-10 3.71E-10 1.73E-11 2.49E-10 9.27E-13 4.42E-10 947 EDRVA 114' E Wall 5.53E-07 2.03E-07 2.73E-11 6.86E-10 1.63E-11 2.90E-08 8.85E-09 6.64E-09 5.00E-09 8.74E-08 5.81E-09 4.56E-10 2.12E-10 9.90E-12 1.43E-10 5.31E-13 2.53E-10 950 EDRVA 114' Floor 9.66E-07 3.54E-07 4.77E-11 1.20E-09 2.84E-11 5.07E-08 1.54E-08 1.16E-08 8.74E-09 1.53E-07 1.01E-08 7.96E-10 3.71E-10 1.73E-11 2.49E-10 9.27E-13 4.42E-10 945 EDRVA 114' N Wall 2.21E-07 8.11E-08 1.09E-11 2.74E-10 6.50E-12 1.16E-08 3.53E-09 2.65E-09 2.00E-09 3.49E-08 2.32E-09 1.82E-10 8.48E-11 3.95E-12 5.70E-11 2.12E-13 1.01E-10 946 EDRVA 114' S Wall 2.23E-08 8.19E-09 1.10E-12 2.77E-11 6.56E-13 1.17E-09 3.57E-10 2.68E-10 2.02E-10 3.53E-09 2.34E-10 1.84E-11 8.57E-12 3.99E-13 5.76E-12 2.14E-14 1.02E-11 948 EDRVA 114' W Wall 5.53E-07 2.03E-07 2.73E-11 6.86E-10 1.63E-11 2.90E-08 8.85E-09 6.64E-09 5.00E-09 8.74E-08 5.81E-09 4.56E-10 2.12E-10 9.90E-12 1.43E-10 5.31E-13 2.53E-10
WVDP-606 Rev. 1 Page 18 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1956 GCRE Ceiling 3.14E-05 1.15E-05 1.55E-09 3.89E-08 9.23E-10 1.65E-06 5.02E-07 3.77E-07 2.84E-07 4.96E-06 3.30E-07 2.59E-08 1.21E-08 5.62E-10 8.10E-09 3.01E-11 1.44E-08 1954 GCRE East Wall 1.79E-05 6.58E-06 8.85E-10 2.22E-08 5.27E-10 9.41E-07 2.87E-07 2.15E-07 1.62E-07 2.83E-06 1.88E-07 1.48E-08 6.88E-09 3.21E-10 4.62E-09 1.72E-11 8.21E-09 1952 GCRE North Wall 2.21E-05 8.11E-06 1.09E-09 2.74E-08 6.50E-10 1.16E-06 3.53E-07 2.65E-07 2.00E-07 3.49E-06 2.32E-07 1.82E-08 8.48E-09 3.95E-10 5.70E-09 2.12E-11 1.01E-08 1953 GCRE South Wall 5.62E-05 2.06E-05 2.78E-09 6.97E-08 1.65E-09 2.95E-06 8.99E-07 6.74E-07 5.08E-07 8.88E-06 5.90E-07 4.63E-08 2.16E-08 1.01E-09 1.45E-08 5.39E-11 2.57E-08 1955 GCRE West Wall 3.45E-06 1.27E-06 1.71E-10 4.28E-09 1.02E-10 1.81E-07 5.52E-08 4.14E-08 3.12E-08 5.46E-07 3.63E-08 2.85E-09 1.33E-09 6.18E-11 8.91E-10 3.31E-12 1.58E-09 924 HAC 144' Ceiling 1.63E-05 5.99E-06 8.06E-10 2.02E-08 4.80E-10 8.56E-07 2.61E-07 1.96E-07 1.48E-07 2.58E-06 1.71E-07 1.34E-08 6.26E-09 2.92E-10 4.21E-09 1.57E-11 7.47E-09 700 HAC 144' E Wall 9.66E-06 3.54E-06 4.77E-10 1.20E-08 2.84E-10 5.07E-07 1.54E-07 1.16E-07 8.74E-08 1.53E-06 1.01E-07 7.96E-09 3.71E-09 1.73E-10 2.49E-09 9.27E-12 4.42E-09 698 HAC 144' Floor 2.87E-04 1.05E-04 1.42E-08 3.56E-07 8.43E-09 1.51E-05 4.59E-06 3.44E-06 2.60E-06 4.53E-05 3.01E-06 2.36E-07 1.10E-07 5.13E-09 7.40E-08 2.75E-10 1.31E-07 702 HAC 144' N Wall 1.54E-05 5.64E-06 7.59E-10 1.90E-08 4.52E-10 8.07E-07 2.46E-07 1.84E-07 1.39E-07 2.43E-06 1.61E-07 1.27E-08 5.90E-09 2.75E-10 3.96E-09 1.47E-11 7.04E-09 701 HAC 144' S Wall 1.14E-05 4.19E-06 5.64E-10 1.42E-08 3.36E-10 5.99E-07 1.83E-07 1.37E-07 1.03E-07 1.80E-06 1.20E-07 9.40E-09 4.38E-09 2.04E-10 2.94E-09 1.10E-11 5.23E-09 699 HAC 144' W Wall 3.86E-06 1.42E-06 1.91E-10 4.79E-09 1.14E-10 2.03E-07 6.18E-08 4.63E-08 3.50E-08 6.10E-07 4.06E-08 3.18E-09 1.48E-09 6.91E-11 9.97E-10 3.71E-12 1.77E-09 2729 HAC 144' Pipe 7310TP03 4.81E-04 1.76E-04 2.37E-08 5.96E-07 1.41E-08 2.52E-05 7.69E-06 5.77E-06 4.35E-06 7.59E-05 5.05E-06 3.96E-07 1.85E-07 8.60E-09 1.24E-07 4.61E-10 2.20E-07 2730 HAC 144' Pipe 7P240 7.21E-09 2.65E-09 3.56E-13 8.94E-12 2.12E-13 3.79E-10 1.15E-10 8.66E-11 6.53E-11 1.14E-09 7.57E-11 5.94E-12 2.77E-12 1.29E-13 1.86E-12 6.92E-15 3.30E-12 2732 HAC 144' Pipe 7P282 7.21E-08 2.65E-08 3.56E-12 8.94E-11 2.12E-12 3.79E-09 1.15E-09 8.66E-10 6.53E-10 1.14E-08 7.57E-10 5.94E-11 2.77E-11 1.29E-12 1.86E-11 6.92E-14 3.30E-11 2733 HAC 144' Pipe SGN div.box 1.46E-08 5.37E-09 7.23E-13 1.81E-11 4.30E-13 7.68E-10 2.34E-10 1.76E-10 1.32E-10 2.31E-09 1.54E-10 1.21E-11 5.62E-12 2.62E-13 3.77E-12 1.40E-14 6.70E-12 2734 HAC 144' Pipe SGN line 4.81E-06 1.76E-06 2.37E-10 5.96E-09 1.41E-10 2.52E-07 7.69E-08 5.77E-08 4.35E-08 7.59E-07 5.05E-08 3.96E-09 1.85E-09 8.60E-11 1.24E-09 4.61E-12 2.20E-09 2735 HAC 144' Pipe skid 21-22 4.33E-06 1.59E-06 2.14E-10 5.37E-09 1.27E-10 2.27E-07 6.93E-08 5.20E-08 3.92E-08 6.84E-07 4.55E-08 3.57E-09 1.66E-09 7.75E-11 1.12E-09 4.16E-12 1.98E-09 1131 HC1 131' All Surfaces 3.37E-06 4.81E-06 8.72E-11 2.02E-09 1.64E-11 5.15E-06 2.59E-06 2.02E-06 1.55E-06 4.04E-06 2.50E-10 1.27E-10 1.29E-10 3.10E-12 2.38E-11 3.23E-12 1.54E-09 1055 HC1 131' Ceiling 9.09E-04 1.30E-03 2.36E-08 5.45E-07 4.43E-09 1.39E-03 6.98E-04 5.46E-04 4.17E-04 1.09E-03 6.77E-08 3.44E-08 3.48E-08 8.38E-10 6.43E-09 8.73E-10 4.17E-07 1053 HC1 131' E Wall 1.08E-03 1.54E-03 2.79E-08 6.46E-07 5.25E-09 1.65E-03 8.28E-04 6.47E-04 4.95E-04 1.29E-03 8.02E-08 4.08E-08 4.13E-08 9.93E-10 7.62E-09 1.04E-09 4.94E-07 1056 HC1 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1051 HC1 131' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1052 HC1 131' S Wall 1.19E-03 1.70E-03 3.08E-08 7.12E-07 5.79E-09 1.82E-03 9.13E-04 7.14E-04 5.46E-04 1.43E-03 8.85E-08 4.50E-08 4.56E-08 1.10E-09 8.41E-09 1.14E-09 5.45E-07 1054 HC1 131' W Wall 5.97E-04 8.53E-04 1.55E-08 3.57E-07 2.91E-09 9.13E-04 4.58E-04 3.58E-04 2.74E-04 7.16E-04 4.44E-08 2.26E-08 2.29E-08 5.50E-10 4.22E-09 5.73E-10 2.73E-07 1066 HC2 131' Ceiling 3.24E-04 2.64E-04 2.74E-08 6.38E-07 1.75E-10 6.93E-05 2.61E-05 2.05E-05 1.57E-05 3.02E-04 8.74E-08 4.30E-08 2.12E-08 8.28E-10 7.57E-09 3.11E-10 1.48E-07 1064 HC2 131' E Wall 4.63E-05 3.78E-05 3.92E-09 9.12E-08 2.50E-11 9.91E-06 3.74E-06 2.94E-06 2.25E-06 4.32E-05 1.25E-08 6.16E-09 3.03E-09 1.18E-10 1.08E-09 4.44E-11 2.12E-08 1067 HC2 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1062 HC2 131' N Wall 3.60E-04 2.95E-04 3.05E-08 7.10E-07 1.95E-10 7.71E-05 2.91E-05 2.29E-05 1.75E-05 3.36E-04 9.73E-08 4.79E-08 2.36E-08 9.23E-10 8.44E-09 3.46E-10 1.65E-07 1063 HC2 131' S Wall 3.19E-05 2.60E-05 2.70E-09 6.28E-08 1.72E-11 6.82E-06 2.57E-06 2.02E-06 1.55E-06 2.97E-05 8.60E-09 4.24E-09 2.08E-09 8.16E-11 7.46E-10 3.06E-11 1.46E-08 1065 HC2 131' W Wall 4.85E-04 3.96E-04 4.10E-08 9.55E-07 2.62E-10 1.04E-04 3.92E-05 3.08E-05 2.36E-05 4.52E-04 1.31E-07 6.45E-08 3.17E-08 1.24E-09 1.13E-08 4.65E-10 2.22E-07 1048 HC3 131' Ceiling 1.08E-03 8.81E-04 9.13E-08 2.13E-06 5.82E-10 2.31E-04 8.72E-05 6.85E-05 5.24E-05 1.01E-03 2.91E-07 1.43E-07 7.05E-08 2.76E-09 2.52E-08 1.04E-09 4.94E-07 1046 HC3 131' E Wall 3.00E-03 2.45E-03 2.54E-07 5.91E-06 1.62E-09 6.42E-04 2.42E-04 1.90E-04 1.46E-04 2.80E-03 8.10E-07 3.99E-07 1.96E-07 7.68E-09 7.02E-08 2.88E-09 1.37E-06 1050 HC3 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1044 HC3 131' N Wall 1.15E-03 9.40E-04 9.73E-08 2.27E-06 6.21E-10 2.46E-04 9.29E-05 7.30E-05 5.59E-05 1.07E-03 3.11E-07 1.53E-07 7.52E-08 2.94E-09 2.69E-08 1.10E-09 5.27E-07 1045 HC3 131' S Wall 1.59E-03 1.30E-03 1.35E-07 3.13E-06 8.59E-10 3.40E-04 1.29E-04 1.01E-04 7.73E-05 1.48E-03 4.29E-07 2.12E-07 1.04E-07 4.07E-09 3.72E-08 1.53E-09 7.28E-07
WVDP-606 Rev. 1 Page 19 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1047 HC3 131' W Wall 7.04E-04 5.76E-04 5.96E-08 1.39E-06 3.80E-10 1.51E-04 5.69E-05 4.47E-05 3.42E-05 6.57E-04 1.90E-07 9.37E-08 4.61E-08 1.80E-09 1.65E-08 6.76E-10 3.23E-07 1072 HC4 131' Ceiling 3.37E-06 5.83E-06 0.00E+00 0.00E+00 6.10E-12 6.37E-06 3.29E-06 2.45E-06 1.90E-06 4.28E-05 0.00E+00 3.67E-17 2.83E-11 7.25E-15 0.00E+00 3.24E-12 1.54E-09 1070 HC4 131' E Wall 1.16E-06 2.00E-06 0.00E+00 0.00E+00 2.10E-12 2.19E-06 1.13E-06 8.42E-07 6.54E-07 1.47E-05 0.00E+00 1.26E-17 9.71E-12 2.49E-15 0.00E+00 1.11E-12 5.30E-10 1073 HC4 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1068 HC4 131' N Wall 4.69E-07 8.11E-07 0.00E+00 0.00E+00 8.49E-13 8.86E-07 4.57E-07 3.41E-07 2.65E-07 5.95E-06 0.00E+00 5.11E-18 3.93E-12 1.01E-15 0.00E+00 4.50E-13 2.15E-10 1069 HC4 131' S Wall 5.05E-06 8.75E-06 0.00E+00 0.00E+00 9.15E-12 9.55E-06 4.93E-06 3.67E-06 2.86E-06 6.42E-05 0.00E+00 5.51E-17 4.24E-11 1.09E-14 0.00E+00 4.85E-12 2.32E-09 1071 HC4 131' W Wall 6.63E-07 1.15E-06 0.00E+00 0.00E+00 1.20E-12 1.25E-06 6.46E-07 4.82E-07 3.75E-07 8.42E-06 0.00E+00 7.23E-18 5.56E-12 1.43E-15 0.00E+00 6.36E-13 3.04E-10 1132 HC5 131' All Surfaces 6.35E-06 5.25E-06 5.43E-10 1.42E-08 0.00E+00 1.07E-06 4.55E-07 3.35E-07 2.57E-07 7.24E-06 1.54E-09 7.05E-10 3.35E-10 1.35E-11 1.24E-10 6.10E-12 2.91E-09 1084 HC5 131' Ceiling 3.42E-04 2.83E-04 2.93E-08 7.63E-07 0.00E+00 5.75E-05 2.45E-05 1.81E-05 1.38E-05 3.90E-04 8.32E-08 3.80E-08 1.81E-08 7.29E-10 6.67E-09 3.29E-10 1.57E-07 1082 HC5 131' E Wall 3.96E-04 3.27E-04 3.39E-08 8.83E-07 0.00E+00 6.65E-05 2.83E-05 2.09E-05 1.60E-05 4.51E-04 9.62E-08 4.40E-08 2.09E-08 8.43E-10 7.72E-09 3.80E-10 1.81E-07 1085 HC5 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1080 HC5 131' N Wall 7.45E-05 6.15E-05 6.37E-09 1.66E-07 0.00E+00 1.25E-05 5.33E-06 3.93E-06 3.01E-06 8.49E-05 1.81E-08 8.27E-09 3.93E-09 1.59E-10 1.45E-09 7.15E-11 3.41E-08 1081 HC5 131' S Wall 5.35E-05 4.41E-05 4.57E-09 1.19E-07 0.00E+00 8.98E-06 3.83E-06 2.82E-06 2.16E-06 6.09E-05 1.30E-08 5.93E-09 2.82E-09 1.14E-10 1.04E-09 5.13E-11 2.45E-08 1083 HC5 131' W Wall 1.51E-04 1.25E-04 1.29E-08 3.37E-07 0.00E+00 2.54E-05 1.08E-05 7.98E-06 6.11E-06 1.72E-04 3.67E-08 1.68E-08 7.98E-09 3.22E-10 2.95E-09 1.45E-10 6.92E-08 870 ICP/Cold LAB 131' Ceiling 2.68E-06 9.83E-07 1.32E-10 3.32E-09 7.87E-11 1.41E-07 4.28E-08 3.21E-08 2.42E-08 4.23E-07 2.81E-08 2.21E-09 1.03E-09 4.79E-11 6.91E-10 2.57E-12 1.23E-09 868 ICP/Cold LAB 131' E Wall 2.37E-06 8.70E-07 1.17E-10 2.94E-09 6.97E-11 1.24E-07 3.79E-08 2.84E-08 2.14E-08 3.74E-07 2.49E-08 1.95E-09 9.10E-10 4.24E-11 6.11E-10 2.28E-12 1.09E-09 871 ICP/Cold LAB 131' Floor 1.21E-06 4.46E-07 6.00E-11 1.51E-09 3.57E-11 6.38E-08 1.94E-08 1.46E-08 1.10E-08 1.92E-07 1.28E-08 1.00E-09 4.66E-10 2.17E-11 3.13E-10 1.17E-12 5.56E-10 866 ICP/Cold LAB 131' N Wall 6.46E-07 2.37E-07 3.19E-11 8.01E-10 1.90E-11 3.39E-08 1.03E-08 7.75E-09 5.85E-09 1.02E-07 6.78E-09 5.32E-10 2.48E-10 1.16E-11 1.67E-10 6.20E-13 2.96E-10 867 ICP/Cold LAB 131' S Wall 1.58E-06 5.80E-07 7.81E-11 1.96E-09 4.65E-11 8.30E-08 2.53E-08 1.90E-08 1.43E-08 2.50E-07 1.66E-08 1.30E-09 6.07E-10 2.83E-11 4.08E-10 1.52E-12 7.24E-10 869 ICP/Cold LAB 131' W Wall 7.90E-07 2.90E-07 3.90E-11 9.80E-10 2.32E-11 4.15E-08 1.26E-08 9.48E-09 7.15E-09 1.25E-07 8.30E-09 6.51E-10 3.03E-10 1.41E-11 2.04E-10 7.58E-13 3.62E-10 965 LWA 100' Ceiling 1.36E-05 4.99E-06 6.72E-10 1.69E-08 4.00E-10 7.14E-07 2.18E-07 1.63E-07 1.23E-07 2.15E-06 1.43E-07 1.12E-08 5.22E-09 2.44E-10 3.51E-09 1.31E-11 6.23E-09 963 LWA 100' E Wall 1.40E-06 5.13E-07 6.90E-11 1.73E-09 4.11E-11 7.34E-08 2.24E-08 1.68E-08 1.26E-08 2.21E-07 1.47E-08 1.15E-09 5.37E-10 2.50E-11 3.60E-10 1.34E-12 6.40E-10 961 LWA 100' N Wall 1.87E-07 6.85E-08 9.22E-12 2.31E-10 5.48E-12 9.79E-09 2.98E-09 2.24E-09 1.69E-09 2.95E-08 1.96E-09 1.54E-10 7.16E-11 3.34E-12 4.81E-11 1.79E-13 8.54E-11 962 LWA 100' S Wall 1.11E-05 4.08E-06 5.49E-10 1.38E-08 3.27E-10 5.84E-07 1.78E-07 1.33E-07 1.01E-07 1.76E-06 1.17E-07 9.16E-09 4.27E-09 1.99E-10 2.87E-09 1.07E-11 5.09E-09 964 LWA 100' W Wall 3.86E-05 1.41E-05 1.90E-09 4.78E-08 1.13E-09 2.02E-06 6.17E-07 4.63E-07 3.49E-07 6.09E-06 4.05E-07 3.18E-08 1.48E-08 6.90E-10 9.95E-09 3.70E-11 1.77E-08 2890 LWA 100' Pipe 15V984 7.21E-10 2.65E-10 3.56E-14 8.94E-13 2.12E-14 3.79E-11 1.15E-11 8.66E-12 6.53E-12 1.14E-10 7.57E-12 5.94E-13 2.77E-13 1.29E-14 1.86E-13 6.92E-16 3.30E-13 1149 LWC 100' 13D-7 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1150 LWC 100' 13D-8 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1151 LWC 100' 3D-2 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1152 LWC 100' 4D-10 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1153 LWC 100' 4D-13 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1154 LWC 100' 4D-8 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1155 LWC 100' 7D-14 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1551 LWC 100' 7D-2 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1156 LWC 100' 7D-8 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
WVDP-606 Rev. 1 Page 20 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1061 LWC 100' Ceiling 3.51E-03 9.39E-03 4.21E-07 9.39E-06 4.00E-08 5.05E-04 1.76E-04 1.30E-04 9.82E-05 1.54E-03 1.24E-05 4.84E-06 2.30E-06 1.61E-08 1.80E-07 3.37E-09 1.61E-06 1059 LWC 100' E Wall 2.31E-03 6.18E-03 2.77E-07 6.18E-06 2.63E-08 3.32E-04 1.16E-04 8.56E-05 6.46E-05 1.01E-03 8.14E-06 3.18E-06 1.51E-06 1.06E-08 1.19E-07 2.21E-09 1.06E-06 1057 LWC 100' N Wall 1.77E-03 4.74E-03 2.12E-07 4.74E-06 2.02E-08 2.55E-04 8.90E-05 6.56E-05 4.95E-05 7.75E-04 6.24E-06 2.44E-06 1.16E-06 8.14E-09 9.09E-08 1.70E-09 8.10E-07 1058 LWC 100' S Wall 8.89E-04 2.38E-03 1.07E-07 2.38E-06 1.01E-08 1.28E-04 4.47E-05 3.30E-05 2.49E-05 3.89E-04 3.14E-06 1.23E-06 5.83E-07 4.09E-09 4.57E-08 8.53E-10 4.07E-07 1060 LWC 100' W Wall 1.08E-03 2.90E-03 1.30E-07 2.90E-06 1.23E-08 1.56E-04 5.44E-05 4.01E-05 3.03E-05 4.74E-04 3.82E-06 1.49E-06 7.09E-07 4.98E-09 5.56E-08 1.04E-09 4.95E-07 1526 LWC 100' Pipe 13P131A 1.49E-08 3.99E-08 1.79E-12 3.99E-11 1.70E-13 2.14E-09 7.49E-10 5.52E-10 4.17E-10 6.52E-09 5.26E-11 2.06E-11 9.77E-12 6.85E-14 7.65E-13 1.43E-14 6.82E-12 2811 LWC 100' Pipe 13P131A 1.49E-07 3.99E-07 1.79E-11 3.99E-10 1.70E-12 2.14E-08 7.49E-09 5.52E-09 4.17E-09 6.52E-08 5.26E-10 2.06E-10 9.77E-11 6.85E-13 7.65E-12 1.43E-13 6.82E-11 1521 LWC 100' Pipe 13P131B 1.40E-09 3.74E-09 1.68E-13 3.74E-12 1.59E-14 2.01E-10 7.03E-11 5.18E-11 3.91E-11 6.12E-10 4.93E-12 1.93E-12 9.16E-13 6.43E-15 7.18E-14 1.34E-15 6.40E-13 2812 LWC 100' Pipe 13P131B 5.57E-08 1.49E-07 6.68E-12 1.49E-10 6.35E-13 8.02E-09 2.80E-09 2.07E-09 1.56E-09 2.44E-08 1.97E-10 7.69E-11 3.65E-11 2.56E-13 2.86E-12 5.35E-14 2.55E-11 1523 LWC 100' Pipe 13P136 1.01E-07 2.69E-07 1.21E-11 2.69E-10 1.15E-12 1.45E-08 5.06E-09 3.73E-09 2.82E-09 4.40E-08 3.55E-10 1.39E-10 6.60E-11 4.63E-13 5.17E-12 9.65E-14 4.60E-11 2813 LWC 100' Pipe 13P136 3.34E-07 8.96E-07 4.01E-11 8.96E-10 3.81E-12 4.81E-08 1.68E-08 1.24E-08 9.36E-09 1.46E-07 1.18E-09 4.61E-10 2.19E-10 1.54E-12 1.72E-11 3.21E-13 1.53E-10 1539 LWC 100' Pipe 13P26 5.95E-05 1.59E-04 7.14E-09 1.59E-07 6.78E-10 8.57E-06 2.99E-06 2.21E-06 1.67E-06 2.61E-05 2.10E-07 8.21E-08 3.90E-08 2.74E-10 3.06E-09 5.71E-11 2.73E-08 2814 LWC 100' Pipe 13P26 1.49E-04 3.99E-04 1.79E-08 3.99E-07 1.70E-09 2.14E-05 7.49E-06 5.52E-06 4.17E-06 6.52E-05 5.26E-07 2.06E-07 9.77E-08 6.85E-10 7.65E-09 1.43E-10 6.82E-08 1504 LWC 100' Pipe 13UA148 1.34E-07 3.59E-07 1.61E-11 3.59E-10 1.53E-12 1.93E-08 6.74E-09 4.97E-09 3.75E-09 5.87E-08 4.73E-10 1.85E-10 8.79E-11 6.16E-13 6.89E-12 1.29E-13 6.14E-11 2815 LWC 100' Pipe 13UA148 7.15E-07 1.92E-06 8.58E-11 1.92E-09 8.15E-12 1.03E-07 3.59E-08 2.65E-08 2.00E-08 3.13E-07 2.52E-09 9.86E-10 4.69E-10 3.29E-12 3.67E-11 6.86E-13 3.27E-10 1514 LWC 100' Pipe 13UA156 5.95E-08 1.59E-07 7.14E-12 1.59E-10 6.78E-13 8.57E-09 2.99E-09 2.21E-09 1.67E-09 2.61E-08 2.10E-10 8.21E-11 3.90E-11 2.74E-13 3.06E-12 5.71E-14 2.73E-11 2816 LWC 100' Pipe 13UA156 4.76E-07 1.27E-06 5.71E-11 1.27E-09 5.42E-12 6.85E-08 2.39E-08 1.76E-08 1.33E-08 2.08E-07 1.68E-09 6.56E-10 3.12E-10 2.19E-12 2.44E-11 4.57E-13 2.18E-10 1541 LWC 100' Pipe 14CH83 8.94E-08 2.40E-07 1.07E-11 2.40E-10 1.02E-12 1.29E-08 4.50E-09 3.32E-09 2.50E-09 3.92E-08 3.16E-10 1.23E-10 5.86E-11 4.11E-13 4.60E-12 8.58E-14 4.09E-11 2817 LWC 100' Pipe 14CH83 2.23E-07 5.99E-07 2.68E-11 5.99E-10 2.55E-12 3.22E-08 1.12E-08 8.29E-09 6.25E-09 9.78E-08 7.88E-10 3.08E-10 1.47E-10 1.03E-12 1.15E-11 2.14E-13 1.02E-10 2818 LWC 100' Pipe 15CH1577 2.51E-06 6.73E-06 3.01E-10 6.73E-09 2.86E-11 3.62E-07 1.26E-07 9.32E-08 7.03E-08 1.10E-06 8.86E-09 3.47E-09 1.65E-09 1.16E-11 1.29E-10 2.41E-12 1.15E-09 2819 LWC 100' Pipe 15CH609 3.56E-07 9.54E-07 4.27E-11 9.54E-10 4.06E-12 5.13E-08 1.79E-08 1.32E-08 9.97E-09 1.56E-07 1.26E-09 4.91E-10 2.34E-10 1.64E-12 1.83E-11 3.42E-13 1.63E-10 1510 LWC 100' Pipe 15CH704 1.49E-08 3.99E-08 1.79E-12 3.99E-11 1.70E-13 2.14E-09 7.49E-10 5.52E-10 4.17E-10 6.52E-09 5.26E-11 2.06E-11 9.77E-12 6.85E-14 7.65E-13 1.43E-14 6.82E-12 2820 LWC 100' Pipe 15CH704 1.19E-07 3.19E-07 1.43E-11 3.19E-10 1.36E-12 1.71E-08 5.99E-09 4.42E-09 3.33E-09 5.21E-08 4.20E-10 1.64E-10 7.81E-11 5.48E-13 6.12E-12 1.14E-13 5.45E-11 1522 LWC 100' Pipe 15CH748 7.15E-08 1.92E-07 8.58E-12 1.92E-10 8.15E-13 1.03E-08 3.59E-09 2.65E-09 2.00E-09 3.13E-08 2.52E-10 9.86E-11 4.69E-11 3.29E-13 3.67E-12 6.86E-14 3.27E-11 2821 LWC 100' Pipe 15CH748 1.79E-07 4.78E-07 2.14E-11 4.78E-10 2.04E-12 2.57E-08 8.98E-09 6.62E-09 5.00E-09 7.82E-08 6.30E-10 2.46E-10 1.17E-10 8.21E-13 9.18E-12 1.71E-13 8.18E-11 1532 LWC 100' Pipe 15CH753 4.76E-08 1.27E-07 5.71E-12 1.27E-10 5.42E-13 6.85E-09 2.39E-09 1.76E-09 1.33E-09 2.08E-08 1.68E-10 6.56E-11 3.12E-11 2.19E-13 2.44E-12 4.57E-14 2.18E-11 2822 LWC 100' Pipe 15CH753 7.15E-08 1.92E-07 8.58E-12 1.92E-10 8.15E-13 1.03E-08 3.59E-09 2.65E-09 2.00E-09 3.13E-08 2.52E-10 9.86E-11 4.69E-11 3.29E-13 3.67E-12 6.86E-14 3.27E-11 1505 LWC 100' Pipe 15CH754 3.34E-09 8.96E-09 4.01E-13 8.96E-12 3.81E-14 4.81E-10 1.68E-10 1.24E-10 9.36E-11 1.46E-09 1.18E-11 4.61E-12 2.19E-12 1.54E-14 1.72E-13 3.21E-15 1.53E-12 2823 LWC 100' Pipe 15CH754 6.71E-09 1.80E-08 8.05E-13 1.80E-11 7.65E-14 9.67E-10 3.38E-10 2.49E-10 1.88E-10 2.94E-09 2.37E-11 9.26E-12 4.40E-12 3.09E-14 3.45E-13 6.44E-15 3.07E-12 1543 LWC 100' Pipe 15UA702 1.79E-07 4.78E-07 2.14E-11 4.78E-10 2.04E-12 2.57E-08 8.98E-09 6.62E-09 5.00E-09 7.82E-08 6.30E-10 2.46E-10 1.17E-10 8.21E-13 9.18E-12 1.71E-13 8.18E-11 2824 LWC 100' Pipe 15UA702 1.43E-06 3.83E-06 1.72E-10 3.83E-09 1.63E-11 2.06E-07 7.19E-08 5.30E-08 4.00E-08 6.26E-07 5.05E-09 1.97E-09 9.38E-10 6.58E-12 7.35E-11 1.37E-12 6.55E-10 2825 LWC 100' Pipe 3P37 7.36E-09 1.97E-08 8.84E-13 1.97E-11 8.40E-14 1.06E-09 3.70E-10 2.73E-10 2.06E-10 3.23E-09 2.60E-11 1.02E-11 4.83E-12 3.39E-14 3.79E-13 7.07E-15 3.37E-12 2826 LWC 100' Pipe 3P65 3.72E-06 9.98E-06 4.47E-10 9.98E-09 4.24E-11 5.36E-07 1.87E-07 1.38E-07 1.04E-07 1.63E-06 1.31E-08 5.14E-09 2.44E-09 1.71E-11 1.91E-10 3.57E-12 1.71E-09 1513 LWC 100' Pipe 3P81A 1.79E-07 4.78E-07 2.14E-11 4.78E-10 2.04E-12 2.57E-08 8.98E-09 6.62E-09 5.00E-09 7.82E-08 6.30E-10 2.46E-10 1.17E-10 8.21E-13 9.18E-12 1.71E-13 8.18E-11 2827 LWC 100' Pipe 3P81A 1.79E-06 4.78E-06 2.14E-10 4.78E-09 2.04E-11 2.57E-07 8.98E-08 6.62E-08 5.00E-08 7.82E-07 6.30E-09 2.46E-09 1.17E-09 8.21E-12 9.18E-11 1.71E-12 8.18E-10
WVDP-606 Rev. 1 Page 21 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1536 LWC 100' Pipe 3P90 6.71E-08 1.80E-07 8.05E-12 1.80E-10 7.65E-13 9.67E-09 3.38E-09 2.49E-09 1.88E-09 2.94E-08 2.37E-10 9.26E-11 4.40E-11 3.09E-13 3.45E-12 6.44E-14 3.07E-11 2828 LWC 100' Pipe 3P90 2.23E-07 5.99E-07 2.68E-11 5.99E-10 2.55E-12 3.22E-08 1.12E-08 8.29E-09 6.25E-09 9.78E-08 7.88E-10 3.08E-10 1.47E-10 1.03E-12 1.15E-11 2.14E-13 1.02E-10 1540 LWC 100' Pipe 3P91 5.95E-07 1.59E-06 7.14E-11 1.59E-09 6.78E-12 8.57E-08 2.99E-08 2.21E-08 1.67E-08 2.61E-07 2.10E-09 8.21E-10 3.90E-10 2.74E-12 3.06E-11 5.71E-13 2.73E-10 2829 LWC 100' Pipe 3P91 1.49E-06 3.99E-06 1.79E-10 3.99E-09 1.70E-11 2.14E-07 7.49E-08 5.52E-08 4.17E-08 6.52E-07 5.26E-09 2.06E-09 9.77E-10 6.85E-12 7.65E-11 1.43E-12 6.82E-10 1542 LWC 100' Pipe 3P92 2.68E-07 7.18E-07 3.22E-11 7.18E-10 3.05E-12 3.86E-08 1.35E-08 9.94E-09 7.50E-09 1.17E-07 9.46E-10 3.70E-10 1.76E-10 1.23E-12 1.38E-11 2.57E-13 1.23E-10 2830 LWC 100' Pipe 3P92 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1501 LWC 100' Pipe 4CW460 6.71E-09 1.80E-08 8.05E-13 1.80E-11 7.65E-14 9.67E-10 3.38E-10 2.49E-10 1.88E-10 2.94E-09 2.37E-11 9.26E-12 4.40E-12 3.09E-14 3.45E-13 6.44E-15 3.07E-12 2831 LWC 100' Pipe 4CW460 2.23E-08 5.99E-08 2.68E-12 5.99E-11 2.55E-13 3.22E-09 1.12E-09 8.29E-10 6.25E-10 9.78E-09 7.88E-11 3.08E-11 1.47E-11 1.03E-13 1.15E-12 2.14E-14 1.02E-11 1516 LWC 100' Pipe 4CW461 1.34E-08 3.59E-08 1.61E-12 3.59E-11 1.53E-13 1.93E-09 6.74E-10 4.97E-10 3.75E-10 5.87E-09 4.73E-11 1.85E-11 8.79E-12 6.16E-14 6.89E-13 1.29E-14 6.14E-12 2832 LWC 100' Pipe 4CW461 4.46E-08 1.19E-07 5.35E-12 1.19E-10 5.08E-13 6.42E-09 2.24E-09 1.65E-09 1.25E-09 1.95E-08 1.57E-10 6.15E-11 2.92E-11 2.05E-13 2.29E-12 4.28E-14 2.04E-11 1499 LWC 100' Pipe 4P398A 5.57E-09 1.49E-08 6.68E-13 1.49E-11 6.35E-14 8.02E-10 2.80E-10 2.07E-10 1.56E-10 2.44E-09 1.97E-11 7.69E-12 3.65E-12 2.56E-14 2.86E-13 5.35E-15 2.55E-12 2833 LWC 100' Pipe 4P398A 5.57E-08 1.49E-07 6.68E-12 1.49E-10 6.35E-13 8.02E-09 2.80E-09 2.07E-09 1.56E-09 2.44E-08 1.97E-10 7.69E-11 3.65E-11 2.56E-13 2.86E-12 5.35E-14 2.55E-11 2834 LWC 100' Pipe 4P438 2.23E-07 5.99E-07 2.68E-11 5.99E-10 2.55E-12 3.22E-08 1.12E-08 8.29E-09 6.25E-09 9.78E-08 7.88E-10 3.08E-10 1.47E-10 1.03E-12 1.15E-11 2.14E-13 1.02E-10 2835 LWC 100' Pipe 4P449 1.55E-07 4.15E-07 1.86E-11 4.15E-10 1.77E-12 2.23E-08 7.79E-09 5.75E-09 4.34E-09 6.78E-08 5.47E-10 2.14E-10 1.02E-10 7.13E-13 7.96E-12 1.49E-13 7.09E-11 2836 LWC 100' Pipe 4P451 1.86E-09 4.99E-09 2.23E-13 4.99E-12 2.12E-14 2.68E-10 9.36E-11 6.91E-11 5.21E-11 8.15E-10 6.57E-12 2.57E-12 1.22E-12 8.56E-15 9.57E-14 1.79E-15 8.53E-13 2837 LWC 100' Pipe 4P457 7.45E-08 2.00E-07 8.93E-12 2.00E-10 8.49E-13 1.07E-08 3.75E-09 2.76E-09 2.08E-09 3.26E-08 2.63E-10 1.03E-10 4.88E-11 3.43E-13 3.83E-12 7.15E-14 3.41E-11 2838 LWC 100' Pipe 4P459 1.12E-07 2.99E-07 1.34E-11 2.99E-10 1.27E-12 1.61E-08 5.62E-09 4.14E-09 3.13E-09 4.89E-08 3.94E-10 1.54E-10 7.33E-11 5.14E-13 5.74E-12 1.07E-13 5.12E-11 1498 LWC 100' Pipe 4P469A 2.42E-09 6.48E-09 2.90E-13 6.48E-12 2.76E-14 3.48E-10 1.22E-10 8.97E-11 6.77E-11 1.06E-09 8.54E-12 3.34E-12 1.59E-12 1.11E-14 1.24E-13 2.32E-15 1.11E-12 2839 LWC 100' Pipe 4P469A 2.42E-08 6.48E-08 2.90E-12 6.48E-11 2.76E-13 3.48E-09 1.22E-09 8.97E-10 6.77E-10 1.06E-08 8.54E-11 3.34E-11 1.59E-11 1.11E-13 1.24E-12 2.32E-14 1.11E-11 1496 LWC 100' Pipe 4P469B 4.65E-11 1.25E-10 5.58E-15 1.25E-13 5.30E-16 6.69E-12 2.34E-12 1.72E-12 1.30E-12 2.04E-11 1.64E-13 6.41E-14 3.05E-14 2.14E-16 2.39E-15 4.46E-17 2.13E-14 2840 LWC 100' Pipe 4P469B 6.06E-09 1.62E-08 7.27E-13 1.62E-11 6.91E-14 8.73E-10 3.05E-10 2.25E-10 1.70E-10 2.65E-09 2.14E-11 8.36E-12 3.98E-12 2.79E-14 3.11E-13 5.82E-15 2.78E-12 2841 LWC 100' Pipe 4P469C 3.64E-09 9.76E-09 4.37E-13 9.76E-12 4.15E-14 5.24E-10 1.83E-10 1.35E-10 1.02E-10 1.59E-09 1.29E-11 5.03E-12 2.39E-12 1.68E-14 1.87E-13 3.50E-15 1.67E-12 2842 LWC 100' Pipe 4P481 1.45E-06 3.89E-06 1.74E-10 3.89E-09 1.65E-11 2.09E-07 7.30E-08 5.38E-08 4.06E-08 6.36E-07 5.12E-09 2.00E-09 9.52E-10 6.68E-12 7.46E-11 1.39E-12 6.65E-10 1546 LWC 100' Pipe 4P501A 5.95E-07 1.59E-06 7.14E-11 1.59E-09 6.78E-12 8.57E-08 2.99E-08 2.21E-08 1.67E-08 2.61E-07 2.10E-09 8.21E-10 3.90E-10 2.74E-12 3.06E-11 5.71E-13 2.73E-10 2843 LWC 100' Pipe 4P501A 5.95E-06 1.59E-05 7.14E-10 1.59E-08 6.78E-11 8.57E-07 2.99E-07 2.21E-07 1.67E-07 2.61E-06 2.10E-08 8.21E-09 3.90E-09 2.74E-11 3.06E-10 5.71E-12 2.73E-09 2844 LWC 100' Pipe 4P501B 1.49E-06 3.99E-06 1.79E-10 3.99E-09 1.70E-11 2.14E-07 7.49E-08 5.52E-08 4.17E-08 6.52E-07 5.26E-09 2.06E-09 9.77E-10 6.85E-12 7.65E-11 1.43E-12 6.82E-10 2845 LWC 100' Pipe 4P501C 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1495 LWC 100' Pipe 4P622A 1.47E-09 3.95E-09 1.77E-13 3.95E-12 1.68E-14 2.12E-10 7.41E-11 5.46E-11 4.12E-11 6.45E-10 5.20E-12 2.03E-12 9.66E-13 6.78E-15 7.57E-14 1.41E-15 6.75E-13 2847 LWC 100' Pipe 4P622A 1.47E-08 3.95E-08 1.77E-12 3.95E-11 1.68E-13 2.12E-09 7.41E-10 5.46E-10 4.12E-10 6.45E-09 5.20E-11 2.03E-11 9.66E-12 6.78E-14 7.57E-13 1.41E-14 6.75E-12 2848 LWC 100' Pipe 4P622B 3.70E-09 9.90E-09 4.43E-13 9.90E-12 4.21E-14 5.32E-10 1.86E-10 1.37E-10 1.03E-10 1.62E-09 1.30E-11 5.10E-12 2.42E-12 1.70E-14 1.90E-13 3.55E-15 1.69E-12 2849 LWC 100' Pipe 4P622C 2.21E-09 5.92E-09 2.65E-13 5.92E-12 2.52E-14 3.18E-10 1.11E-10 8.20E-11 6.19E-11 9.68E-10 7.80E-12 3.05E-12 1.45E-12 1.02E-14 1.14E-13 2.12E-15 1.01E-12 2850 LWC 100' Pipe 4P627 8.97E-09 2.40E-08 1.08E-12 2.40E-11 1.02E-13 1.29E-09 4.51E-10 3.33E-10 2.51E-10 3.93E-09 3.17E-11 1.24E-11 5.88E-12 4.13E-14 4.61E-13 8.61E-15 4.11E-12 2851 LWC 100' Pipe 4P630 8.97E-09 2.40E-08 1.08E-12 2.40E-11 1.02E-13 1.29E-09 4.51E-10 3.33E-10 2.51E-10 3.93E-09 3.17E-11 1.24E-11 5.88E-12 4.13E-14 4.61E-13 8.61E-15 4.11E-12 2852 LWC 100' Pipe 4P632 1.99E-08 5.35E-08 2.39E-12 5.35E-11 2.27E-13 2.87E-09 1.00E-09 7.40E-10 5.58E-10 8.74E-09 7.04E-11 2.75E-11 1.31E-11 9.18E-14 1.03E-12 1.91E-14 9.14E-12 1528 LWC 100' Pipe 4P71 3.34E-08 8.96E-08 4.01E-12 8.96E-11 3.81E-13 4.81E-09 1.68E-09 1.24E-09 9.36E-10 1.46E-08 1.18E-10 4.61E-11 2.19E-11 1.54E-13 1.72E-12 3.21E-14 1.53E-11
WVDP-606 Rev. 1 Page 22 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2853 LWC 100' Pipe 4P71 1.12E-07 2.99E-07 1.34E-11 2.99E-10 1.27E-12 1.61E-08 5.62E-09 4.14E-09 3.13E-09 4.89E-08 3.94E-10 1.54E-10 7.33E-11 5.14E-13 5.74E-12 1.07E-13 5.12E-11 1533 LWC 100' Pipe 4S470 6.71E-08 1.80E-07 8.05E-12 1.80E-10 7.65E-13 9.67E-09 3.38E-09 2.49E-09 1.88E-09 2.94E-08 2.37E-10 9.26E-11 4.40E-11 3.09E-13 3.45E-12 6.44E-14 3.07E-11 2854 LWC 100' Pipe 4S470 4.46E-07 1.19E-06 5.35E-11 1.19E-09 5.08E-12 6.42E-08 2.24E-08 1.65E-08 1.25E-08 1.95E-07 1.57E-09 6.15E-10 2.92E-10 2.05E-12 2.29E-11 4.28E-13 2.04E-10 1497 LWC 100' Pipe 4S471 1.67E-09 4.49E-09 2.01E-13 4.49E-12 1.91E-14 2.41E-10 8.42E-11 6.21E-11 4.69E-11 7.33E-10 5.91E-12 2.31E-12 1.10E-12 7.70E-15 8.60E-14 1.61E-15 7.67E-13 2855 LWC 100' Pipe 4S471 1.12E-08 2.99E-08 1.34E-12 2.99E-11 1.27E-13 1.61E-09 5.62E-10 4.14E-10 3.13E-10 4.89E-09 3.94E-11 1.54E-11 7.33E-12 5.14E-14 5.74E-13 1.07E-14 5.12E-12 1511 LWC 100' Pipe 4S496 2.74E-08 7.36E-08 3.29E-12 7.36E-11 3.13E-13 3.95E-09 1.38E-09 1.02E-09 7.68E-10 1.20E-08 9.69E-11 3.79E-11 1.80E-11 1.26E-13 1.41E-12 2.63E-14 1.26E-11 2856 LWC 100' Pipe 4S496 5.46E-08 1.46E-07 6.55E-12 1.46E-10 6.23E-13 7.87E-09 2.75E-09 2.03E-09 1.53E-09 2.39E-08 1.93E-10 7.54E-11 3.58E-11 2.51E-13 2.81E-12 5.24E-14 2.50E-11 1509 LWC 100' Pipe 4S497 3.61E-08 9.69E-08 4.34E-12 9.69E-11 4.12E-13 5.20E-09 1.82E-09 1.34E-09 1.01E-09 1.58E-08 1.28E-10 4.99E-11 2.37E-11 1.66E-13 1.86E-12 3.47E-14 1.66E-11 2857 LWC 100' Pipe 4S497 7.23E-08 1.94E-07 8.67E-12 1.94E-10 8.24E-13 1.04E-08 3.64E-09 2.68E-09 2.02E-09 3.17E-08 2.55E-10 9.98E-11 4.74E-11 3.33E-13 3.72E-12 6.94E-14 3.31E-11 1506 LWC 100' Pipe 4S498 2.74E-08 7.36E-08 3.29E-12 7.36E-11 3.13E-13 3.95E-09 1.38E-09 1.02E-09 7.68E-10 1.20E-08 9.69E-11 3.79E-11 1.80E-11 1.26E-13 1.41E-12 2.63E-14 1.26E-11 2858 LWC 100' Pipe 4S498 5.46E-08 1.46E-07 6.55E-12 1.46E-10 6.23E-13 7.87E-09 2.75E-09 2.03E-09 1.53E-09 2.39E-08 1.93E-10 7.54E-11 3.58E-11 2.51E-13 2.81E-12 5.24E-14 2.50E-11 1508 LWC 100' Pipe 4S619 8.70E-08 2.33E-07 1.04E-11 2.33E-10 9.91E-13 1.25E-08 4.37E-09 3.23E-09 2.43E-09 3.81E-08 3.07E-10 1.20E-10 5.70E-11 4.00E-13 4.47E-12 8.35E-14 3.98E-11 2859 LWC 100' Pipe 4S619 1.74E-07 4.67E-07 2.09E-11 4.67E-10 1.99E-12 2.51E-08 8.76E-09 6.46E-09 4.88E-09 7.63E-08 6.15E-10 2.40E-10 1.14E-10 8.01E-13 8.95E-12 1.67E-13 7.98E-11 1507 LWC 100' Pipe 4S620 3.61E-08 9.69E-08 4.34E-12 9.69E-11 4.12E-13 5.20E-09 1.82E-09 1.34E-09 1.01E-09 1.58E-08 1.28E-10 4.99E-11 2.37E-11 1.66E-13 1.86E-12 3.47E-14 1.66E-11 2860 LWC 100' Pipe 4S620 7.23E-08 1.94E-07 8.67E-12 1.94E-10 8.24E-13 1.04E-08 3.64E-09 2.68E-09 2.02E-09 3.17E-08 2.55E-10 9.98E-11 4.74E-11 3.33E-13 3.72E-12 6.94E-14 3.31E-11 1515 LWC 100' Pipe 4S621 4.48E-08 1.20E-07 5.38E-12 1.20E-10 5.11E-13 6.46E-09 2.26E-09 1.66E-09 1.26E-09 1.96E-08 1.58E-10 6.19E-11 2.94E-11 2.06E-13 2.30E-12 4.30E-14 2.05E-11 2861 LWC 100' Pipe 4S621 8.97E-08 2.40E-07 1.08E-11 2.40E-10 1.02E-12 1.29E-08 4.51E-09 3.33E-09 2.51E-09 3.93E-08 3.17E-10 1.24E-10 5.88E-11 4.13E-13 4.61E-12 8.61E-14 4.11E-11 1502 LWC 100' Pipe 4S626 4.48E-09 1.20E-08 5.38E-13 1.20E-11 5.11E-14 6.46E-10 2.26E-10 1.66E-10 1.26E-10 1.96E-09 1.58E-11 6.19E-12 2.94E-12 2.06E-14 2.30E-13 4.30E-15 2.05E-12 2862 LWC 100' Pipe 4S626 8.97E-09 2.40E-08 1.08E-12 2.40E-11 1.02E-13 1.29E-09 4.51E-10 3.33E-10 2.51E-10 3.93E-09 3.17E-11 1.24E-11 5.88E-12 4.13E-14 4.61E-13 8.61E-15 4.11E-12 1500 LWC 100' Pipe 4UA468 3.34E-08 8.96E-08 4.01E-12 8.96E-11 3.81E-13 4.81E-09 1.68E-09 1.24E-09 9.36E-10 1.46E-08 1.18E-10 4.61E-11 2.19E-11 1.54E-13 1.72E-12 3.21E-14 1.53E-11 2863 LWC 100' Pipe 4UA468 2.23E-07 5.99E-07 2.68E-11 5.99E-10 2.55E-12 3.22E-08 1.12E-08 8.29E-09 6.25E-09 9.78E-08 7.88E-10 3.08E-10 1.47E-10 1.03E-12 1.15E-11 2.14E-13 1.02E-10 1527 LWC 100' Pipe 4UA502 4.46E-07 1.19E-06 5.35E-11 1.19E-09 5.08E-12 6.42E-08 2.24E-08 1.65E-08 1.25E-08 1.95E-07 1.57E-09 6.15E-10 2.92E-10 2.05E-12 2.29E-11 4.28E-13 2.04E-10 2864 LWC 100' Pipe 4UA502 1.34E-06 3.59E-06 1.61E-10 3.59E-09 1.53E-11 1.93E-07 6.74E-08 4.97E-08 3.75E-08 5.87E-07 4.73E-09 1.85E-09 8.79E-10 6.16E-12 6.89E-11 1.29E-12 6.14E-10 1544 LWC 100' Pipe 5CH588 7.45E-08 2.00E-07 8.93E-12 2.00E-10 8.49E-13 1.07E-08 3.75E-09 2.76E-09 2.08E-09 3.26E-08 2.63E-10 1.03E-10 4.88E-11 3.43E-13 3.83E-12 7.15E-14 3.41E-11 2865 LWC 100' Pipe 5CH588 7.45E-07 2.00E-06 8.93E-11 2.00E-09 8.49E-12 1.07E-07 3.75E-08 2.76E-08 2.08E-08 3.26E-07 2.63E-09 1.03E-09 4.88E-10 3.43E-12 3.83E-11 7.15E-13 3.41E-10 1530 LWC 100' Pipe 5P199 1.60E-08 4.27E-08 1.91E-12 4.27E-11 1.82E-13 2.30E-09 8.02E-10 5.92E-10 4.47E-10 6.99E-09 5.63E-11 2.20E-11 1.05E-11 7.34E-14 8.20E-13 1.53E-14 7.31E-12 2866 LWC 100' Pipe 5P199 7.99E-08 2.14E-07 9.59E-12 2.14E-10 9.11E-13 1.15E-08 4.02E-09 2.96E-09 2.24E-09 3.50E-08 2.82E-10 1.10E-10 5.24E-11 3.68E-13 4.11E-12 7.67E-14 3.66E-11 1550 LWC 100' Pipe 6P104 1.57E-03 4.21E-03 1.88E-07 4.21E-06 1.79E-08 2.26E-04 7.90E-05 5.83E-05 4.40E-05 6.88E-04 5.54E-06 2.17E-06 1.03E-06 7.23E-09 8.07E-08 1.51E-09 7.19E-07 2867 LWC 100' Pipe 6P104 1.96E-03 5.27E-03 2.36E-07 5.27E-06 2.24E-08 2.83E-04 9.88E-05 7.29E-05 5.50E-05 8.61E-04 6.94E-06 2.71E-06 1.29E-06 9.04E-09 1.01E-07 1.89E-09 9.00E-07 2868 LWC 100' Pipe 6P105 5.98E-04 1.60E-03 7.17E-08 1.60E-06 6.82E-09 8.61E-05 3.01E-05 2.22E-05 1.67E-05 2.62E-04 2.11E-06 8.25E-07 3.92E-07 2.75E-09 3.07E-08 5.74E-10 2.74E-07 1531 LWC 100' Pipe 6P82 3.56E-07 9.54E-07 4.27E-11 9.54E-10 4.06E-12 5.13E-08 1.79E-08 1.32E-08 9.97E-09 1.56E-07 1.26E-09 4.91E-10 2.34E-10 1.64E-12 1.83E-11 3.42E-13 1.63E-10 2869 LWC 100' Pipe 6P82 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1534 LWC 100' Pipe 7J56A 2.99E-08 8.01E-08 3.59E-12 8.01E-11 3.41E-13 4.30E-09 1.50E-09 1.11E-09 8.37E-10 1.31E-08 1.06E-10 4.13E-11 1.96E-11 1.38E-13 1.54E-12 2.87E-14 1.37E-11 2870 LWC 100' Pipe 7J56A 2.99E-07 8.01E-07 3.59E-11 8.01E-10 3.41E-12 4.30E-08 1.50E-08 1.11E-08 8.37E-09 1.31E-07 1.06E-09 4.13E-10 1.96E-10 1.38E-12 1.54E-11 2.87E-13 1.37E-10 1535 LWC 100' Pipe 7J56B 8.94E-08 2.40E-07 1.07E-11 2.40E-10 1.02E-12 1.29E-08 4.50E-09 3.32E-09 2.50E-09 3.92E-08 3.16E-10 1.23E-10 5.86E-11 4.11E-13 4.60E-12 8.58E-14 4.09E-11
WVDP-606 Rev. 1 Page 23 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2871 LWC 100' Pipe 7J56B 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1537 LWC 100' Pipe 7J56C 8.94E-08 2.40E-07 1.07E-11 2.40E-10 1.02E-12 1.29E-08 4.50E-09 3.32E-09 2.50E-09 3.92E-08 3.16E-10 1.23E-10 5.86E-11 4.11E-13 4.60E-12 8.58E-14 4.09E-11 2872 LWC 100' Pipe 7J56C 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1549 LWC 100' Pipe 7P10 1.12E-06 2.99E-06 1.34E-10 2.99E-09 1.27E-11 1.61E-07 5.62E-08 4.14E-08 3.13E-08 4.89E-07 3.94E-09 1.54E-09 7.33E-10 5.14E-12 5.74E-11 1.07E-12 5.12E-10 2873 LWC 100' Pipe 7P10 3.34E-06 8.96E-06 4.01E-10 8.96E-09 3.81E-11 4.81E-07 1.68E-07 1.24E-07 9.36E-08 1.46E-06 1.18E-08 4.61E-09 2.19E-09 1.54E-11 1.72E-10 3.21E-12 1.53E-09 1545 LWC 100' Pipe 7P13 2.68E-07 7.18E-07 3.22E-11 7.18E-10 3.05E-12 3.86E-08 1.35E-08 9.94E-09 7.50E-09 1.17E-07 9.46E-10 3.70E-10 1.76E-10 1.23E-12 1.38E-11 2.57E-13 1.23E-10 2874 LWC 100' Pipe 7P13 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1524 LWC 100' Pipe 7P153 1.01E-07 2.69E-07 1.21E-11 2.69E-10 1.15E-12 1.45E-08 5.06E-09 3.73E-09 2.82E-09 4.40E-08 3.55E-10 1.39E-10 6.60E-11 4.63E-13 5.17E-12 9.65E-14 4.60E-11 2875 LWC 100' Pipe 7P153 3.34E-07 8.96E-07 4.01E-11 8.96E-10 3.81E-12 4.81E-08 1.68E-08 1.24E-08 9.36E-09 1.46E-07 1.18E-09 4.61E-10 2.19E-10 1.54E-12 1.72E-11 3.21E-13 1.53E-10 1517 LWC 100' Pipe 7P16 6.71E-08 1.80E-07 8.05E-12 1.80E-10 7.65E-13 9.67E-09 3.38E-09 2.49E-09 1.88E-09 2.94E-08 2.37E-10 9.26E-11 4.40E-11 3.09E-13 3.45E-12 6.44E-14 3.07E-11 2876 LWC 100' Pipe 7P16 2.23E-07 5.99E-07 2.68E-11 5.99E-10 2.55E-12 3.22E-08 1.12E-08 8.29E-09 6.25E-09 9.78E-08 7.88E-10 3.08E-10 1.47E-10 1.03E-12 1.15E-11 2.14E-13 1.02E-10 2877 LWC 100' Pipe 7P17 9.10E-08 2.44E-07 1.09E-11 2.44E-10 1.04E-12 1.31E-08 4.58E-09 3.38E-09 2.55E-09 3.99E-08 3.21E-10 1.26E-10 5.97E-11 4.19E-13 4.68E-12 8.74E-14 4.17E-11 2878 LWC 100' Pipe 7P18 1.79E-07 4.78E-07 2.14E-11 4.78E-10 2.04E-12 2.57E-08 8.98E-09 6.62E-09 5.00E-09 7.82E-08 6.30E-10 2.46E-10 1.17E-10 8.21E-13 9.18E-12 1.71E-13 8.18E-11 2879 LWC 100' Pipe 7P20 1.12E-06 2.99E-06 1.34E-10 2.99E-09 1.27E-11 1.61E-07 5.62E-08 4.14E-08 3.13E-08 4.89E-07 3.94E-09 1.54E-09 7.33E-10 5.14E-12 5.74E-11 1.07E-12 5.12E-10 1548 LWC 100' Pipe 7P25 2.68E-07 7.18E-07 3.22E-11 7.18E-10 3.05E-12 3.86E-08 1.35E-08 9.94E-09 7.50E-09 1.17E-07 9.46E-10 3.70E-10 1.76E-10 1.23E-12 1.38E-11 2.57E-13 1.23E-10 2880 LWC 100' Pipe 7P25 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.50E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.11E-12 4.60E-11 8.58E-13 4.09E-10 1525 LWC 100' Pipe 7P59 1.01E-06 2.69E-06 1.21E-10 2.69E-09 1.15E-11 1.45E-07 5.06E-08 3.73E-08 2.82E-08 4.40E-07 3.55E-09 1.39E-09 6.60E-10 4.63E-12 5.17E-11 9.65E-13 4.60E-10 2881 LWC 100' Pipe 7P59 3.34E-06 8.96E-06 4.01E-10 8.96E-09 3.81E-11 4.81E-07 1.68E-07 1.24E-07 9.36E-08 1.46E-06 1.18E-08 4.61E-09 2.19E-09 1.54E-11 1.72E-10 3.21E-12 1.53E-09 1529 LWC 100' Pipe 7P62 4.02E-07 1.08E-06 4.83E-11 1.08E-09 4.58E-12 5.79E-08 2.02E-08 1.49E-08 1.13E-08 1.76E-07 1.42E-09 5.55E-10 2.64E-10 1.85E-12 2.07E-11 3.86E-13 1.84E-10 2882 LWC 100' Pipe 7P62 1.34E-06 3.59E-06 1.61E-10 3.59E-09 1.53E-11 1.93E-07 6.74E-08 4.97E-08 3.75E-08 5.87E-07 4.73E-09 1.85E-09 8.79E-10 6.16E-12 6.89E-11 1.29E-12 6.14E-10 1538 LWC 100' Pipe 7P63 4.76E-08 1.27E-07 5.71E-12 1.27E-10 5.42E-13 6.85E-09 2.39E-09 1.76E-09 1.33E-09 2.08E-08 1.68E-10 6.56E-11 3.12E-11 2.19E-13 2.44E-12 4.57E-14 2.18E-11 2883 LWC 100' Pipe 7P63 9.54E-08 2.56E-07 1.14E-11 2.56E-10 1.09E-12 1.37E-08 4.80E-09 3.54E-09 2.67E-09 4.18E-08 3.37E-10 1.32E-10 6.26E-11 4.39E-13 4.90E-12 9.16E-14 4.37E-11 2884 LWC 100' Pipe 7P83 1.99E-07 5.35E-07 2.39E-11 5.35E-10 2.27E-12 2.87E-08 1.00E-08 7.40E-09 5.58E-09 8.74E-08 7.04E-10 2.75E-10 1.31E-10 9.18E-13 1.03E-11 1.91E-13 9.14E-11 1520 LWC 100' Pipe 7P96 2.38E-06 6.38E-06 2.86E-10 6.38E-09 2.71E-11 3.43E-07 1.20E-07 8.83E-08 6.67E-08 1.04E-06 8.40E-09 3.29E-09 1.56E-09 1.10E-11 1.22E-10 2.29E-12 1.09E-09 2885 LWC 100' Pipe 7P96 5.95E-06 1.59E-05 7.14E-10 1.59E-08 6.78E-11 8.57E-07 2.99E-07 2.21E-07 1.67E-07 2.61E-06 2.10E-08 8.21E-09 3.90E-09 2.74E-11 3.06E-10 5.71E-12 2.73E-09 1503 LWC 100' Pipe 7S24 1.67E-08 4.49E-08 2.01E-12 4.49E-11 1.91E-13 2.41E-09 8.42E-10 6.21E-10 4.69E-10 7.33E-09 5.91E-11 2.31E-11 1.10E-11 7.70E-14 8.60E-13 1.61E-14 7.67E-12 2886 LWC 100' Pipe 7S24 8.94E-08 2.40E-07 1.07E-11 2.40E-10 1.02E-12 1.29E-08 4.50E-09 3.32E-09 2.50E-09 3.92E-08 3.16E-10 1.23E-10 5.86E-11 4.11E-13 4.60E-12 8.58E-14 4.09E-11 1512 LWC 100' Pipe 7S58 1.01E-07 2.69E-07 1.21E-11 2.69E-10 1.15E-12 1.45E-08 5.06E-09 3.73E-09 2.82E-09 4.40E-08 3.55E-10 1.39E-10 6.60E-11 4.63E-13 5.17E-12 9.65E-14 4.60E-11 2887 LWC 100' Pipe 7S58 6.71E-07 1.80E-06 8.05E-11 1.80E-09 7.65E-12 9.67E-08 3.38E-08 2.49E-08 1.88E-08 2.94E-07 2.37E-09 9.26E-10 4.40E-10 3.09E-12 3.45E-11 6.44E-13 3.07E-10 1519 LWC 100' Pipe 7S61 4.18E-08 1.12E-07 5.02E-12 1.12E-10 4.77E-13 6.03E-09 2.10E-09 1.55E-09 1.17E-09 1.83E-08 1.48E-10 5.78E-11 2.75E-11 1.93E-13 2.15E-12 4.02E-14 1.92E-11 2888 LWC 100' Pipe 7S61 2.80E-07 7.50E-07 3.36E-11 7.50E-10 3.19E-12 4.03E-08 1.41E-08 1.04E-08 7.84E-09 1.23E-07 9.88E-10 3.86E-10 1.84E-10 1.29E-12 1.44E-11 2.69E-13 1.28E-10 1518 LWC 100' Pipe 7UA52 6.71E-09 1.80E-08 8.05E-13 1.80E-11 7.65E-14 9.67E-10 3.38E-10 2.49E-10 1.88E-10 2.94E-09 2.37E-11 9.26E-12 4.40E-12 3.09E-14 3.45E-13 6.44E-15 3.07E-12 2889 LWC 100' Pipe 7UA52 2.23E-08 5.99E-08 2.68E-12 5.99E-11 2.55E-13 3.22E-09 1.12E-09 8.29E-10 6.25E-10 9.78E-09 7.88E-11 3.08E-11 1.47E-11 1.03E-13 1.15E-12 2.14E-14 1.02E-11 955 LXA 114' Ceiling 1.92E-03 7.03E-04 9.47E-08 2.38E-06 5.63E-08 1.01E-04 3.07E-05 2.30E-05 1.73E-05 3.03E-04 2.01E-05 1.58E-06 7.36E-07 3.43E-08 4.94E-07 1.84E-09 8.78E-07 959 LXA 114' Ceiling 7.61E-05 2.79E-05 3.76E-09 9.43E-08 2.24E-09 3.99E-06 1.22E-06 9.13E-07 6.89E-07 1.20E-05 7.99E-07 6.27E-08 2.92E-08 1.36E-09 1.96E-08 7.30E-11 3.48E-08
WVDP-606 Rev. 1 Page 24 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 953 LXA 114' E Wall 1.91E-07 7.01E-08 9.43E-12 2.37E-10 5.61E-12 1.00E-08 3.05E-09 2.29E-09 1.73E-09 3.02E-08 2.00E-09 1.57E-10 7.33E-11 3.42E-12 4.93E-11 1.83E-13 8.74E-11 956 LXA 114' Floor 9.22E-04 3.38E-04 4.55E-08 1.14E-06 2.71E-08 4.84E-05 1.47E-05 1.11E-05 8.34E-06 1.46E-04 9.68E-06 7.60E-07 3.54E-07 1.65E-08 2.38E-07 8.85E-10 4.22E-07 960 LXA 114' Floor 9.44E-08 3.46E-08 4.66E-12 1.17E-10 2.77E-12 4.95E-09 1.51E-09 1.13E-09 8.54E-10 1.49E-08 9.91E-10 7.78E-11 3.62E-11 1.69E-12 2.43E-11 9.06E-14 4.32E-11 951 LXA 114' N Wall 1.92E-03 7.03E-04 9.47E-08 2.38E-06 5.63E-08 1.01E-04 3.07E-05 2.30E-05 1.73E-05 3.03E-04 2.01E-05 1.58E-06 7.36E-07 3.43E-08 4.94E-07 1.84E-09 8.78E-07 957 LXA 114' N Wall 1.50E-04 5.50E-05 7.41E-09 1.86E-07 4.41E-09 7.87E-06 2.40E-06 1.80E-06 1.36E-06 2.37E-05 1.57E-06 1.24E-07 5.76E-08 2.68E-09 3.87E-08 1.44E-10 6.87E-08 952 LXA 114' S Wall 5.70E-06 2.09E-06 2.82E-10 7.07E-09 1.68E-10 2.99E-07 9.12E-08 6.84E-08 5.16E-08 9.00E-07 5.98E-08 4.70E-09 2.19E-09 1.02E-10 1.47E-09 5.47E-12 2.61E-09 958 LXA 114' S Wall 1.89E-06 6.95E-07 9.36E-11 2.35E-09 5.57E-11 9.95E-08 3.03E-08 2.27E-08 1.71E-08 2.99E-07 1.99E-08 1.56E-09 7.28E-10 3.39E-11 4.89E-10 1.82E-12 8.68E-10 954 LXA 114' W Wall 1.25E-04 4.59E-05 6.18E-09 1.55E-07 3.68E-09 6.57E-06 2.00E-06 1.50E-06 1.13E-06 1.98E-05 1.31E-06 1.03E-07 4.80E-08 2.24E-09 3.23E-08 1.20E-10 5.73E-08 1569 LXA 114' Pipe 13S151 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1570 LXA 114' Pipe 13UA148 9.89E-07 1.64E-06 6.03E-11 1.30E-09 1.40E-11 3.57E-06 1.22E-06 7.95E-07 6.06E-07 1.07E-05 5.68E-10 6.23E-09 3.02E-09 4.56E-09 1.19E-09 9.49E-13 4.53E-10 1571 LXA 114' Pipe 13UA156 6.58E-07 1.09E-06 4.01E-11 8.62E-10 9.34E-12 2.38E-06 8.09E-07 5.29E-07 4.03E-07 7.11E-06 3.78E-10 4.14E-09 2.01E-09 3.03E-09 7.89E-10 6.32E-13 3.01E-10 1572 LXA 114' Pipe 14CH2178 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 2806 LXA 114' Pipe 15P1805 3.01E-06 1.10E-06 1.49E-10 3.73E-09 8.84E-11 1.58E-07 4.81E-08 3.61E-08 2.72E-08 4.75E-07 3.16E-08 2.48E-09 1.15E-09 5.38E-11 7.76E-10 2.89E-12 1.38E-09 1578 LXA 114' Pipe 15S720 1.85E-08 3.08E-08 1.13E-12 2.43E-11 2.63E-13 6.69E-08 2.28E-08 1.49E-08 1.14E-08 2.00E-07 1.06E-11 1.17E-10 5.65E-11 8.54E-11 2.22E-11 1.78E-14 8.49E-12 1581 LXA 114' Pipe 15UA702 1.98E-06 3.28E-06 1.21E-10 2.59E-09 2.81E-11 7.14E-06 2.43E-06 1.59E-06 1.21E-06 2.14E-05 1.14E-09 1.25E-08 6.03E-09 9.12E-09 2.37E-09 1.90E-12 9.06E-10 1587 LXA 114' Pipe 4P622C 3.06E-09 5.07E-09 1.86E-13 4.00E-12 4.34E-14 1.10E-08 3.76E-09 2.46E-09 1.87E-09 3.30E-08 1.75E-12 1.93E-11 9.32E-12 1.41E-11 3.67E-12 2.93E-15 1.40E-12 1593 LXA 114' Pipe 4S496 7.56E-08 1.25E-07 4.61E-12 9.90E-11 1.07E-12 2.73E-07 9.29E-08 6.08E-08 4.63E-08 8.16E-07 4.34E-11 4.76E-10 2.30E-10 3.48E-10 9.07E-11 7.25E-14 3.46E-11 1594 LXA 114' Pipe 4S619 2.41E-07 4.00E-07 1.47E-11 3.16E-10 3.42E-12 8.70E-07 2.96E-07 1.94E-07 1.48E-07 2.60E-06 1.38E-10 1.52E-09 7.35E-10 1.11E-09 2.89E-10 2.31E-13 1.10E-10 1595 LXA 114' Pipe 4S620 1.00E-07 1.66E-07 6.10E-12 1.31E-10 1.42E-12 3.61E-07 1.23E-07 8.04E-08 6.13E-08 1.08E-06 5.74E-11 6.30E-10 3.05E-10 4.61E-10 1.20E-10 9.60E-14 4.58E-11 1596 LXA 114' Pipe 4S621 1.24E-07 2.06E-07 7.57E-12 1.63E-10 1.76E-12 4.48E-07 1.53E-07 9.97E-08 7.60E-08 1.34E-06 7.12E-11 7.82E-10 3.78E-10 5.72E-10 1.49E-10 1.19E-13 5.68E-11 1597 LXA 114' Pipe 4S626 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 1606 LXA 114' Pipe 5CW189 5.56E-06 9.24E-06 3.39E-10 7.29E-09 7.90E-11 2.01E-05 6.84E-06 4.47E-06 3.41E-06 6.01E-05 3.19E-09 3.51E-08 1.70E-08 2.56E-08 6.68E-09 5.34E-12 2.55E-09 1607 LXA 114' Pipe 6-71-136 9.51E-08 1.58E-07 5.80E-12 1.25E-10 1.35E-12 3.43E-07 1.17E-07 7.65E-08 5.83E-08 1.03E-06 5.46E-11 5.99E-10 2.90E-10 4.38E-10 1.14E-10 9.13E-14 4.36E-11 1608 LXA 114' Pipe 7CH22 1.55E-06 2.56E-06 9.43E-11 2.02E-09 2.19E-11 5.58E-06 1.90E-06 1.24E-06 9.47E-07 1.67E-05 8.87E-10 9.73E-09 4.71E-09 7.12E-09 1.85E-09 1.48E-12 7.08E-10 1610 LXA 114' Pipe 7J21A 5.15E-07 8.55E-07 3.14E-11 6.75E-10 7.31E-12 1.86E-06 6.33E-07 4.14E-07 3.16E-07 5.56E-06 2.96E-10 3.24E-09 1.57E-09 2.37E-09 6.18E-10 4.94E-13 2.36E-10 1616 LXA 114' Pipe 7S24 1.24E-07 2.05E-07 7.54E-12 1.62E-10 1.76E-12 4.47E-07 1.52E-07 9.94E-08 7.58E-08 1.34E-06 7.10E-11 7.79E-10 3.77E-10 5.70E-10 1.48E-10 1.19E-13 5.66E-11 1619 LXA 114' Pipe 7S9 1.61E-08 2.66E-08 9.79E-13 2.10E-11 2.28E-13 5.80E-08 1.97E-08 1.29E-08 9.84E-09 1.73E-07 9.21E-12 1.01E-10 4.90E-11 7.40E-11 1.93E-11 1.54E-14 7.35E-12 876 Mass Spec/Alpha LAB 131' Ceiling 1.75E-05 6.42E-06 8.64E-10 2.17E-08 5.14E-10 9.18E-07 2.80E-07 2.10E-07 1.58E-07 2.76E-06 1.84E-07 1.44E-08 6.71E-09 3.13E-10 4.51E-09 1.68E-11 8.01E-09 882 Mass Spec/Alpha LAB 131' Ceiling 6.56E-05 2.41E-05 3.24E-09 8.14E-08 1.93E-09 3.44E-06 1.05E-06 7.87E-07 5.94E-07 1.04E-05 6.89E-07 5.41E-08 2.52E-08 1.17E-09 1.69E-08 6.30E-11 3.01E-08 874 Mass Spec/Alpha LAB 131' E Wall 2.82E-06 1.04E-06 1.39E-10 3.50E-09 8.30E-11 1.48E-07 4.52E-08 3.39E-08 2.56E-08 4.46E-07 2.96E-08 2.33E-09 1.08E-09 5.05E-11 7.29E-10 2.71E-12 1.29E-09 880 Mass Spec/Alpha LAB 131' E Wall 4.26E-05 1.57E-05 2.11E-09 5.29E-08 1.25E-09 2.24E-06 6.82E-07 5.12E-07 3.86E-07 6.74E-06 4.48E-07 3.51E-08 1.64E-08 7.63E-10 1.10E-08 4.09E-11 1.95E-08 877 Mass Spec/Alpha LAB 131' Floor 2.17E-06 7.97E-07 1.07E-10 2.69E-09 6.39E-11 1.14E-07 3.48E-08 2.61E-08 1.97E-08 3.43E-07 2.28E-08 1.79E-09 8.34E-10 3.89E-11 5.61E-10 2.09E-12 9.95E-10 883 Mass Spec/Alpha LAB 131' Floor 1.01E-05 3.70E-06 4.99E-10 1.25E-08 2.97E-10 5.30E-07 1.62E-07 1.21E-07 9.14E-08 1.60E-06 1.06E-07 8.32E-09 3.88E-09 1.81E-10 2.60E-09 9.69E-12 4.62E-09 872 Mass Spec/Alpha LAB 131' N Wall 8.19E-07 3.01E-07 4.05E-11 1.02E-09 2.41E-11 4.30E-08 1.31E-08 9.83E-09 7.41E-09 1.29E-07 8.60E-09 6.75E-10 3.15E-10 1.47E-11 2.11E-10 7.87E-13 3.75E-10
WVDP-606 Rev. 1 Page 25 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 878 Mass Spec/Alpha LAB 131' N Wall 6.68E-06 2.45E-06 3.30E-10 8.28E-09 1.96E-10 3.51E-07 1.07E-07 8.01E-08 6.04E-08 1.06E-06 7.01E-08 5.50E-09 2.56E-09 1.20E-10 1.72E-09 6.41E-12 3.06E-09 873 Mass Spec/Alpha LAB 131' S Wall 9.07E-06 3.33E-06 4.48E-10 1.12E-08 2.67E-10 4.76E-07 1.45E-07 1.09E-07 8.21E-08 1.43E-06 9.52E-08 7.47E-09 3.48E-09 1.62E-10 2.34E-09 8.71E-12 4.15E-09 879 Mass Spec/Alpha LAB 131' S Wall 1.24E-05 4.54E-06 6.11E-10 1.53E-08 3.63E-10 6.49E-07 1.98E-07 1.48E-07 1.12E-07 1.95E-06 1.30E-07 1.02E-08 4.75E-09 2.21E-10 3.19E-09 1.19E-11 5.66E-09 875 Mass Spec/Alpha LAB 131' W Wall 2.31E-06 8.48E-07 1.14E-10 2.87E-09 6.80E-11 1.21E-07 3.70E-08 2.77E-08 2.09E-08 3.65E-07 2.43E-08 1.90E-09 8.88E-10 4.14E-11 5.96E-10 2.22E-12 1.06E-09 881 Mass Spec/Alpha LAB 131' W Wall 4.93E-06 1.81E-06 2.44E-10 6.11E-09 1.45E-10 2.59E-07 7.89E-08 5.92E-08 4.46E-08 7.79E-07 5.18E-08 4.06E-09 1.89E-09 8.83E-11 1.27E-09 4.73E-12 2.26E-09 763 MOA Level Ceiling 3.72E-05 1.36E-05 1.84E-09 4.61E-08 1.09E-09 1.95E-06 5.95E-07 4.46E-07 3.36E-07 5.87E-06 3.90E-07 3.06E-08 1.43E-08 6.65E-10 9.59E-09 3.57E-11 1.70E-08 766 MOA Level Ceiling 1.05E-06 3.84E-07 5.17E-11 1.30E-09 3.08E-11 5.49E-08 1.67E-08 1.26E-08 9.47E-09 1.65E-07 1.10E-08 8.62E-10 4.02E-10 1.87E-11 2.70E-10 1.00E-12 4.79E-10 771 MOA Level Ceiling 9.44E-05 3.46E-05 4.66E-09 1.17E-07 2.77E-09 4.95E-06 1.51E-06 1.13E-06 8.54E-07 1.49E-05 9.91E-07 7.78E-08 3.62E-08 1.69E-09 2.43E-08 9.06E-11 4.32E-08 776 MOA Level Ceiling 1.57E-05 5.77E-06 7.77E-10 1.95E-08 4.62E-10 8.26E-07 2.52E-07 1.89E-07 1.42E-07 2.49E-06 1.65E-07 1.30E-08 6.04E-09 2.82E-10 4.06E-09 1.51E-11 7.20E-09 761 MOA Level E Wall 3.06E-05 1.12E-05 1.51E-09 3.79E-08 8.99E-10 1.61E-06 4.89E-07 3.67E-07 2.77E-07 4.83E-06 3.21E-07 2.52E-08 1.17E-08 5.47E-10 7.89E-09 2.94E-11 1.40E-08 769 MOA Level E Wall 8.85E-05 3.25E-05 4.37E-09 1.10E-07 2.60E-09 4.65E-06 1.42E-06 1.06E-06 8.01E-07 1.40E-05 9.29E-07 7.29E-08 3.40E-08 1.58E-09 2.28E-08 8.50E-11 4.05E-08 774 MOA Level E Wall 1.16E-05 4.27E-06 5.75E-10 1.44E-08 3.42E-10 6.11E-07 1.86E-07 1.40E-07 1.05E-07 1.84E-06 1.22E-07 9.58E-09 4.47E-09 2.08E-10 3.00E-09 1.12E-11 5.33E-09 759 MOA Level N Wall 3.23E-06 1.19E-06 1.60E-10 4.01E-09 9.51E-11 1.70E-07 5.17E-08 3.88E-08 2.93E-08 5.11E-07 3.40E-08 2.66E-09 1.24E-09 5.79E-11 8.34E-10 3.10E-12 1.48E-09 764 MOA Level N Wall 6.04E-08 2.21E-08 2.98E-12 7.48E-11 1.77E-12 3.17E-09 9.66E-10 7.24E-10 5.46E-10 9.54E-09 6.34E-10 4.97E-11 2.32E-11 1.08E-12 1.56E-11 5.79E-14 2.76E-11 767 MOA Level N Wall 2.08E-07 7.62E-08 1.03E-11 2.58E-10 6.11E-12 1.09E-08 3.32E-09 2.49E-09 1.88E-09 3.28E-08 2.18E-09 1.71E-10 7.98E-11 3.72E-12 5.36E-11 1.99E-13 9.52E-11 772 MOA Level N Wall 5.25E-07 1.93E-07 2.59E-11 6.51E-10 1.54E-11 2.76E-08 8.40E-09 6.30E-09 4.75E-09 8.30E-08 5.51E-09 4.33E-10 2.02E-10 9.40E-12 1.36E-10 5.04E-13 2.41E-10 760 MOA Level S Wall 2.15E-06 7.89E-07 1.06E-10 2.67E-09 6.32E-11 1.13E-07 3.44E-08 2.58E-08 1.95E-08 3.40E-07 2.26E-08 1.77E-09 8.26E-10 3.85E-11 5.55E-10 2.06E-12 9.85E-10 765 MOA Level S Wall 2.44E-06 8.94E-07 1.20E-10 3.02E-09 7.16E-11 1.28E-07 3.90E-08 2.92E-08 2.20E-08 3.85E-07 2.56E-08 2.01E-09 9.35E-10 4.36E-11 6.28E-10 2.34E-12 1.12E-09 768 MOA Level S Wall 8.27E-07 3.03E-07 4.08E-11 1.03E-09 2.43E-11 4.34E-08 1.32E-08 9.92E-09 7.48E-09 1.31E-07 8.68E-09 6.81E-10 3.17E-10 1.48E-11 2.13E-10 7.94E-13 3.79E-10 773 MOA Level S Wall 2.31E-06 8.48E-07 1.14E-10 2.87E-09 6.80E-11 1.21E-07 3.70E-08 2.77E-08 2.09E-08 3.65E-07 2.43E-08 1.90E-09 8.88E-10 4.14E-11 5.96E-10 2.22E-12 1.06E-09 762 MOA Level W Wall 2.44E-05 8.94E-06 1.20E-09 3.02E-08 7.16E-10 1.28E-06 3.90E-07 2.92E-07 2.20E-07 3.85E-06 2.56E-07 2.01E-08 9.35E-09 4.36E-10 6.28E-09 2.34E-11 1.12E-08 770 MOA Level W Wall 1.52E-06 5.58E-07 7.52E-11 1.89E-09 4.47E-11 7.99E-08 2.43E-08 1.83E-08 1.38E-08 2.40E-07 1.60E-08 1.25E-09 5.84E-10 2.72E-11 3.93E-10 1.46E-12 6.97E-10 775 MOA Level W Wall 9.00E-06 3.30E-06 4.44E-10 1.12E-08 2.65E-10 4.72E-07 1.44E-07 1.08E-07 8.14E-08 1.42E-06 9.45E-08 7.41E-09 3.46E-09 1.61E-10 2.32E-09 8.64E-12 4.12E-09 1130 MRR Ceiling 2.18E-04 1.14E-04 2.06E-08 3.69E-07 1.11E-10 2.32E-05 5.92E-06 4.76E-06 3.60E-06 3.45E-05 2.29E-08 1.89E-08 9.28E-09 1.83E-09 6.66E-09 2.10E-10 1.00E-07 1128 MRR E Wall 1.50E-04 7.80E-05 1.42E-08 2.54E-07 7.65E-11 1.59E-05 4.07E-06 3.27E-06 2.48E-06 2.37E-05 1.58E-08 1.30E-08 6.38E-09 1.26E-09 4.58E-09 1.44E-10 6.87E-08 1126 MRR N Wall 2.90E-04 1.51E-04 2.74E-08 4.90E-07 1.48E-10 3.08E-05 7.86E-06 6.32E-06 4.79E-06 4.58E-05 3.05E-08 2.51E-08 1.23E-08 2.43E-09 8.85E-09 2.79E-10 1.33E-07 1127 MRR S Wall 6.43E-04 3.35E-04 6.08E-08 1.09E-06 3.28E-10 6.82E-05 1.74E-05 1.40E-05 1.06E-05 1.02E-04 6.76E-08 5.56E-08 2.73E-08 5.39E-09 1.96E-08 6.18E-10 2.95E-07 1129 MRR W Wall 1.38E-04 7.15E-05 1.30E-08 2.32E-07 7.01E-11 1.46E-05 3.73E-06 3.00E-06 2.27E-06 2.17E-05 1.44E-08 1.19E-08 5.84E-09 1.15E-09 4.19E-09 1.32E-10 6.30E-08 753 MSM South Ceiling 1.09E-05 4.00E-06 5.38E-10 1.35E-08 3.20E-10 5.72E-07 1.74E-07 1.31E-07 9.86E-08 1.72E-06 1.14E-07 8.98E-09 4.19E-09 1.95E-10 2.81E-09 1.05E-11 4.99E-09 751 MSM South E Wall 5.46E-06 2.00E-06 2.70E-10 6.77E-09 1.60E-10 2.87E-07 8.73E-08 6.55E-08 4.94E-08 8.62E-07 5.73E-08 4.50E-09 2.10E-09 9.77E-11 1.41E-09 5.24E-12 2.50E-09 749 MSM South N Wall 2.93E-06 1.08E-06 1.45E-10 3.64E-09 8.62E-11 1.54E-07 4.69E-08 3.52E-08 2.65E-08 4.63E-07 3.08E-08 2.42E-09 1.13E-09 5.25E-11 7.57E-10 2.82E-12 1.34E-09 750 MSM South S Wall 2.05E-06 7.52E-07 1.01E-10 2.54E-09 6.02E-11 1.08E-07 3.28E-08 2.46E-08 1.85E-08 3.24E-07 2.15E-08 1.69E-09 7.87E-10 3.67E-11 5.28E-10 1.97E-12 9.38E-10 752 MSM South W Wall 1.98E-05 7.28E-06 9.79E-10 2.46E-08 5.83E-10 1.04E-06 3.17E-07 2.38E-07 1.79E-07 3.13E-06 2.08E-07 1.63E-08 7.61E-09 3.55E-10 5.11E-09 1.90E-11 9.08E-09 1922 N. Stairs Ceiling 5.03E-06 1.85E-06 2.49E-10 6.24E-09 1.48E-10 2.64E-07 8.05E-08 6.04E-08 4.55E-08 7.95E-07 5.28E-08 4.15E-09 1.93E-09 9.01E-11 1.30E-09 4.83E-12 2.31E-09
WVDP-606 Rev. 1 Page 26 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1919 N. Stairs East Wall 1.76E-05 6.47E-06 8.71E-10 2.19E-08 5.18E-10 9.26E-07 2.82E-07 2.12E-07 1.60E-07 2.79E-06 1.85E-07 1.45E-08 6.77E-09 3.16E-10 4.55E-09 1.69E-11 8.07E-09 1921 N. Stairs Landing 2.44E-06 8.94E-07 1.20E-10 3.02E-09 7.16E-11 1.28E-07 3.90E-08 2.92E-08 2.20E-08 3.85E-07 2.56E-08 2.01E-09 9.35E-10 4.36E-11 6.28E-10 2.34E-12 1.12E-09 1917 N. Stairs North Wall 2.66E-05 9.77E-06 1.32E-09 3.30E-08 7.83E-10 1.40E-06 4.26E-07 3.20E-07 2.41E-07 4.21E-06 2.80E-07 2.19E-08 1.02E-08 4.77E-10 6.87E-09 2.56E-11 1.22E-08 1918 N. Stairs South Wall 9.22E-06 3.38E-06 4.55E-10 1.14E-08 2.71E-10 4.84E-07 1.47E-07 1.11E-07 8.34E-08 1.46E-06 9.68E-08 7.60E-09 3.54E-09 1.65E-10 2.38E-09 8.85E-12 4.22E-09 1920 N. Stairs West Wall 4.89E-06 1.80E-06 2.42E-10 6.07E-09 1.44E-10 2.57E-07 7.83E-08 5.87E-08 4.43E-08 7.73E-07 5.14E-08 4.03E-09 1.88E-09 8.76E-11 1.26E-09 4.70E-12 2.24E-09 888 OGA 131' Ceiling 2.19E-05 8.03E-06 1.08E-09 2.71E-08 6.43E-10 1.15E-06 3.50E-07 2.62E-07 1.98E-07 3.46E-06 2.30E-07 1.80E-08 8.40E-09 3.92E-10 5.64E-09 2.10E-11 1.00E-08 886 OGA 131' E Wall 5.75E-06 2.11E-06 2.84E-10 7.13E-09 1.69E-10 3.02E-07 9.20E-08 6.90E-08 5.20E-08 9.08E-07 6.04E-08 4.74E-09 2.21E-09 1.03E-10 1.48E-09 5.52E-12 2.63E-09 889 OGA 131' Floor 3.11E-03 1.14E-03 1.54E-07 3.86E-06 9.14E-08 1.63E-04 4.97E-05 3.73E-05 2.81E-05 4.91E-04 3.26E-05 2.56E-06 1.19E-06 5.57E-08 8.02E-07 2.98E-09 1.42E-06 884 OGA 131' N Wall 8.05E-08 2.95E-08 3.98E-12 9.98E-11 2.37E-12 4.22E-09 1.29E-09 9.66E-10 7.28E-10 1.27E-08 8.45E-10 6.63E-11 3.09E-11 1.44E-12 2.08E-11 7.72E-14 3.69E-11 885 OGA 131' S Wall 7.97E-07 2.93E-07 3.94E-11 9.89E-10 2.34E-11 4.19E-08 1.28E-08 9.57E-09 7.22E-09 1.26E-07 8.37E-09 6.57E-10 3.06E-10 1.43E-11 2.06E-10 7.65E-13 3.65E-10 887 OGA 131' W Wall 2.98E-05 1.09E-05 1.47E-09 3.69E-08 8.75E-10 1.56E-06 4.76E-07 3.57E-07 2.69E-07 4.70E-06 3.13E-07 2.45E-08 1.14E-08 5.33E-10 7.68E-09 2.86E-11 1.36E-08 2803 OGA 131' Pipe 6P95 4.86E-05 1.30E-04 5.84E-09 1.30E-07 5.55E-10 7.00E-06 2.45E-06 1.80E-06 1.37E-06 2.13E-05 1.72E-07 6.71E-08 3.19E-08 2.23E-10 2.50E-09 4.67E-11 2.23E-08 971 OGBR Ceiling 1.55E-04 4.16E-04 1.86E-08 4.16E-07 1.77E-09 2.23E-05 7.80E-06 5.76E-06 4.36E-06 6.80E-05 5.48E-07 2.84E-07 1.02E-07 7.12E-10 7.98E-09 1.49E-10 7.11E-08 969 OGBR E Wall 1.10E-04 2.95E-04 1.32E-08 2.95E-07 1.25E-09 1.58E-05 5.54E-06 4.08E-06 3.09E-06 4.82E-05 3.88E-07 2.01E-07 7.21E-08 5.05E-10 5.66E-09 1.06E-10 5.04E-08 967 OGBR N Wall 3.94E-05 1.06E-04 4.73E-09 1.06E-07 4.49E-10 5.67E-06 1.98E-06 1.46E-06 1.11E-06 1.73E-05 1.39E-07 7.21E-08 2.58E-08 1.81E-10 2.03E-09 3.78E-11 1.80E-08 968 OGBR S Wall 2.12E-04 5.68E-04 2.54E-08 5.68E-07 2.42E-09 3.05E-05 1.07E-05 7.86E-06 5.96E-06 9.28E-05 7.48E-07 3.88E-07 1.39E-07 9.73E-10 1.09E-08 2.03E-10 9.71E-08 970 OGBR W Wall 4.38E-05 1.17E-04 5.25E-09 1.17E-07 4.99E-10 6.30E-06 2.20E-06 1.62E-06 1.23E-06 1.92E-05 1.54E-07 8.01E-08 2.87E-08 2.01E-10 2.25E-09 4.20E-11 2.00E-08 538 OGC Ceiling 3.67E-03 9.83E-03 4.40E-07 9.83E-06 4.18E-08 5.28E-04 1.85E-04 1.36E-04 1.03E-04 1.61E-03 1.29E-05 5.06E-06 2.40E-06 1.68E-08 1.89E-07 3.52E-09 1.68E-06 535 OGC E Wall 2.38E-03 6.37E-03 2.85E-07 6.37E-06 2.71E-08 3.42E-04 1.20E-04 8.82E-05 6.68E-05 1.04E-03 8.39E-06 3.28E-06 1.56E-06 1.09E-08 1.22E-07 2.28E-09 1.09E-06 528 OGC N Wall 6.55E-03 1.76E-02 7.86E-07 1.76E-05 7.47E-08 9.43E-04 3.29E-04 2.43E-04 1.84E-04 2.87E-03 2.31E-05 9.04E-06 4.29E-06 3.01E-08 3.37E-07 6.29E-09 3.00E-06 533 OGC NE Wall 1.49E-03 3.98E-03 1.78E-07 3.98E-06 1.69E-08 2.14E-04 7.48E-05 5.51E-05 4.18E-05 6.51E-04 5.25E-06 2.05E-06 9.74E-07 6.82E-09 7.64E-08 1.43E-09 6.81E-07 540 OGC S Wall 1.67E-03 4.47E-03 2.00E-07 4.47E-06 1.90E-08 2.40E-04 8.39E-05 6.19E-05 4.69E-05 7.31E-04 5.89E-06 2.30E-06 1.09E-06 7.66E-09 8.58E-08 1.60E-09 7.64E-07 534 OGC W Wall 1.35E-03 3.62E-03 1.62E-07 3.62E-06 1.54E-08 1.94E-04 6.79E-05 5.01E-05 3.80E-05 5.92E-04 4.77E-06 1.86E-06 8.85E-07 6.20E-09 6.94E-08 1.30E-09 6.19E-07 2736 OGC Pipe 13P136 2.23E-08 5.99E-08 2.68E-12 5.99E-11 2.55E-13 3.22E-09 1.12E-09 8.29E-10 6.28E-10 9.78E-09 7.88E-11 3.08E-11 1.46E-11 1.03E-13 1.15E-12 2.14E-14 1.02E-11 2737 OGC Pipe 13P136 4.46E-09 1.19E-08 5.35E-13 1.19E-11 5.08E-14 6.42E-10 2.24E-10 1.65E-10 1.25E-10 1.95E-09 1.57E-11 6.15E-12 2.92E-12 2.05E-14 2.29E-13 4.28E-15 2.04E-12 2738 OGC Pipe 14CH53 7.15E-09 1.92E-08 8.58E-13 1.92E-11 8.15E-14 1.03E-09 3.59E-10 2.65E-10 2.01E-10 3.13E-09 2.52E-11 9.86E-12 4.68E-12 3.28E-14 3.67E-13 6.86E-15 3.27E-12 2739 OGC Pipe 14CH54 2.99E-08 8.01E-08 3.59E-12 8.01E-11 3.41E-13 4.30E-09 1.50E-09 1.11E-09 8.40E-10 1.31E-08 1.06E-10 4.13E-11 1.96E-11 1.37E-13 1.54E-12 2.87E-14 1.37E-11 2740 OGC Pipe 14CH61 3.56E-08 9.54E-08 4.27E-12 9.54E-11 4.06E-13 5.13E-09 1.79E-09 1.32E-09 1.00E-09 1.56E-08 1.26E-10 4.91E-11 2.33E-11 1.63E-13 1.83E-12 3.42E-14 1.63E-11 2741 OGC Pipe 14CH62 3.56E-08 9.54E-08 4.27E-12 9.54E-11 4.06E-13 5.13E-09 1.79E-09 1.32E-09 1.00E-09 1.56E-08 1.26E-10 4.91E-11 2.33E-11 1.63E-13 1.83E-12 3.42E-14 1.63E-11 2742 OGC Pipe 15P1482 2.77E-08 7.43E-08 3.33E-12 7.43E-11 3.16E-13 3.99E-09 1.39E-09 1.03E-09 7.79E-10 1.21E-08 9.78E-11 3.83E-11 1.82E-11 1.27E-13 1.42E-12 2.66E-14 1.27E-11 2743 OGC Pipe 15S718 2.01E-07 5.39E-07 2.41E-11 5.39E-10 2.29E-12 2.90E-08 1.01E-08 7.46E-09 5.65E-09 8.81E-08 7.10E-10 2.78E-10 1.32E-10 9.23E-13 1.03E-11 1.93E-13 9.21E-11 2744 OGC Pipe 3P22 3.94E-07 1.06E-06 4.73E-11 1.06E-09 4.49E-12 5.67E-08 1.98E-08 1.46E-08 1.11E-08 1.73E-07 1.39E-09 5.44E-10 2.58E-10 1.81E-12 2.03E-11 3.78E-13 1.80E-10 2745 OGC Pipe 6CH118 7.15E-08 1.92E-07 8.58E-12 1.92E-10 8.15E-13 1.03E-08 3.59E-09 2.65E-09 2.01E-09 3.13E-08 2.52E-10 9.86E-11 4.68E-11 3.28E-13 3.67E-12 6.86E-14 3.27E-11 2746 OGC Pipe 6CW1 4.48E-08 1.20E-07 5.38E-12 1.20E-10 5.11E-13 6.46E-09 2.26E-09 1.66E-09 1.26E-09 1.96E-08 1.58E-10 6.19E-11 2.94E-11 2.06E-13 2.30E-12 4.30E-14 2.05E-11 2747 OGC Pipe 6IA123 8.94E-06 2.40E-05 1.07E-09 2.40E-08 1.02E-10 1.29E-06 4.50E-07 3.32E-07 2.51E-07 3.92E-06 3.16E-08 1.23E-08 5.86E-09 4.10E-11 4.60E-10 8.58E-12 4.09E-09
WVDP-606 Rev. 1 Page 27 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2748 OGC Pipe 6IA124 4.78E-07 1.28E-06 5.74E-11 1.28E-09 5.45E-12 6.89E-08 2.41E-08 1.77E-08 1.34E-08 2.09E-07 1.69E-09 6.60E-10 3.13E-10 2.20E-12 2.46E-11 4.59E-13 2.19E-10 2749 OGC Pipe 6J107 4.78E-07 1.28E-06 5.74E-11 1.28E-09 5.45E-12 6.89E-08 2.41E-08 1.77E-08 1.34E-08 2.09E-07 1.69E-09 6.60E-10 3.13E-10 2.20E-12 2.46E-11 4.59E-13 2.19E-10 2750 OGC Pipe 6J110 8.94E-06 2.40E-05 1.07E-09 2.40E-08 1.02E-10 1.29E-06 4.50E-07 3.32E-07 2.51E-07 3.92E-06 3.16E-08 1.23E-08 5.86E-09 4.10E-11 4.60E-10 8.58E-12 4.09E-09 2751 OGC Pipe 6J38 1.79E-08 4.78E-08 2.14E-12 4.78E-11 2.04E-13 2.57E-09 8.98E-10 6.62E-10 5.02E-10 7.82E-09 6.30E-11 2.46E-11 1.17E-11 8.19E-14 9.18E-13 1.71E-14 8.18E-12 2752 OGC Pipe 6J41 1.59E-07 4.27E-07 1.91E-11 4.27E-10 1.82E-12 2.29E-08 8.01E-09 5.91E-09 4.47E-09 6.97E-08 5.62E-10 2.20E-10 1.04E-10 7.31E-13 8.18E-12 1.53E-13 7.29E-11 2753 OGC Pipe 6J52 1.72E-06 4.62E-06 2.07E-10 4.62E-09 1.96E-11 2.48E-07 8.67E-08 6.39E-08 4.84E-08 7.55E-07 6.08E-09 2.38E-09 1.13E-09 7.91E-12 8.86E-11 1.65E-12 7.89E-10 2754 OGC Pipe 6J53 5.35E-07 1.43E-06 6.42E-11 1.43E-09 6.10E-12 7.71E-08 2.69E-08 1.99E-08 1.50E-08 2.34E-07 1.89E-09 7.39E-10 3.51E-10 2.46E-12 2.75E-11 5.14E-13 2.45E-10 2755 OGC Pipe 6J55A 1.79E-08 4.78E-08 2.14E-12 4.78E-11 2.04E-13 2.57E-09 8.98E-10 6.62E-10 5.02E-10 7.82E-09 6.30E-11 2.46E-11 1.17E-11 8.19E-14 9.18E-13 1.71E-14 8.18E-12 2756 OGC Pipe 6J55B 1.79E-08 4.78E-08 2.14E-12 4.78E-11 2.04E-13 2.57E-09 8.98E-10 6.62E-10 5.02E-10 7.82E-09 6.30E-11 2.46E-11 1.17E-11 8.19E-14 9.18E-13 1.71E-14 8.18E-12 2757 OGC Pipe 6J55C 1.79E-08 4.78E-08 2.14E-12 4.78E-11 2.04E-13 2.57E-09 8.98E-10 6.62E-10 5.02E-10 7.82E-09 6.30E-11 2.46E-11 1.17E-11 8.19E-14 9.18E-13 1.71E-14 8.18E-12 2758 OGC Pipe 6J6 4.46E-09 1.19E-08 5.35E-13 1.19E-11 5.08E-14 6.42E-10 2.24E-10 1.65E-10 1.25E-10 1.95E-09 1.57E-11 6.15E-12 2.92E-12 2.05E-14 2.29E-13 4.28E-15 2.04E-12 2759 OGC Pipe 6J65 4.46E-09 1.19E-08 5.35E-13 1.19E-11 5.08E-14 6.42E-10 2.24E-10 1.65E-10 1.25E-10 1.95E-09 1.57E-11 6.15E-12 2.92E-12 2.05E-14 2.29E-13 4.28E-15 2.04E-12 2760 OGC Pipe 6J7 2.24E-07 6.02E-07 2.69E-11 6.02E-10 2.56E-12 3.23E-08 1.13E-08 8.33E-09 6.31E-09 9.83E-08 7.92E-10 3.10E-10 1.47E-10 1.03E-12 1.15E-11 2.15E-13 1.03E-10 2761 OGC Pipe 6J9A 7.47E-08 2.00E-07 8.97E-12 2.00E-10 8.52E-13 1.08E-08 3.76E-09 2.77E-09 2.10E-09 3.27E-08 2.64E-10 1.03E-10 4.89E-11 3.43E-13 3.84E-12 7.17E-14 3.42E-11 2762 OGC Pipe 6J9B 7.47E-08 2.00E-07 8.97E-12 2.00E-10 8.52E-13 1.08E-08 3.76E-09 2.77E-09 2.10E-09 3.27E-08 2.64E-10 1.03E-10 4.89E-11 3.43E-13 3.84E-12 7.17E-14 3.42E-11 2763 OGC Pipe 6J9C 7.47E-08 2.00E-07 8.97E-12 2.00E-10 8.52E-13 1.08E-08 3.76E-09 2.77E-09 2.10E-09 3.27E-08 2.64E-10 1.03E-10 4.89E-11 3.43E-13 3.84E-12 7.17E-14 3.42E-11 2764 OGC Pipe 6P100 3.56E-05 9.54E-05 4.27E-09 9.54E-08 4.06E-10 5.13E-06 1.79E-06 1.32E-06 1.00E-06 1.56E-05 1.26E-07 4.91E-08 2.33E-08 1.63E-10 1.83E-09 3.42E-11 1.63E-08 2765 OGC Pipe 6P101 1.91E-06 5.12E-06 2.29E-10 5.12E-09 2.18E-11 2.75E-07 9.61E-08 7.09E-08 5.37E-08 8.37E-07 6.74E-09 2.64E-09 1.25E-09 8.77E-12 9.82E-11 1.83E-12 8.75E-10 2766 OGC Pipe 6P102 4.76E-06 1.27E-05 5.71E-10 1.27E-08 5.42E-11 6.85E-07 2.39E-07 1.76E-07 1.34E-07 2.08E-06 1.68E-08 6.56E-09 3.11E-09 2.18E-11 2.44E-10 4.57E-12 2.18E-09 2767 OGC Pipe 6P104 4.76E-07 1.27E-06 5.71E-11 1.27E-09 5.42E-12 6.85E-08 2.39E-08 1.76E-08 1.34E-08 2.08E-07 1.68E-09 6.56E-10 3.11E-10 2.18E-12 2.44E-11 4.57E-13 2.18E-10 2768 OGC Pipe 6P126 1.79E-09 4.78E-09 2.14E-13 4.78E-12 2.04E-14 2.57E-10 8.98E-11 6.62E-11 5.02E-11 7.82E-10 6.30E-12 2.46E-12 1.17E-12 8.19E-15 9.18E-14 1.71E-15 8.18E-13 2769 OGC Pipe 6P127 5.35E-07 1.43E-06 6.42E-11 1.43E-09 6.10E-12 7.71E-08 2.69E-08 1.99E-08 1.50E-08 2.34E-07 1.89E-09 7.39E-10 3.51E-10 2.46E-12 2.75E-11 5.14E-13 2.45E-10 2770 OGC Pipe 6P128 1.07E-07 2.87E-07 1.28E-11 2.87E-10 1.22E-12 1.54E-08 5.39E-09 3.97E-09 3.01E-09 4.69E-08 3.78E-10 1.48E-10 7.01E-11 4.91E-13 5.50E-12 1.03E-13 4.90E-11 2771 OGC Pipe 6P137 5.95E-10 1.59E-09 7.14E-14 1.59E-12 6.78E-15 8.57E-11 2.99E-11 2.21E-11 1.67E-11 2.61E-10 2.10E-12 8.21E-13 3.90E-13 2.73E-15 3.06E-14 5.71E-16 2.73E-13 2772 OGC Pipe 6P54A 5.95E-08 1.59E-07 7.14E-12 1.59E-10 6.78E-13 8.57E-09 2.99E-09 2.21E-09 1.67E-09 2.61E-08 2.10E-10 8.21E-11 3.90E-11 2.73E-13 3.06E-12 5.71E-14 2.73E-11 2773 OGC Pipe 6P54B 1.49E-08 3.99E-08 1.79E-12 3.99E-11 1.70E-13 2.14E-09 7.49E-10 5.52E-10 4.18E-10 6.52E-09 5.26E-11 2.06E-11 9.75E-12 6.84E-14 7.65E-13 1.43E-14 6.82E-12 2774 OGC Pipe 6P54C 1.49E-08 3.99E-08 1.79E-12 3.99E-11 1.70E-13 2.14E-09 7.49E-10 5.52E-10 4.18E-10 6.52E-09 5.26E-11 2.06E-11 9.75E-12 6.84E-14 7.65E-13 1.43E-14 6.82E-12 2775 OGC Pipe 6P79A 1.34E-07 3.59E-07 1.61E-11 3.59E-10 1.53E-12 1.93E-08 6.74E-09 4.97E-09 3.76E-09 5.87E-08 4.73E-10 1.85E-10 8.77E-11 6.15E-13 6.89E-12 1.29E-13 6.14E-11 2776 OGC Pipe 6P79B 8.94E-09 2.40E-08 1.07E-12 2.40E-11 1.02E-13 1.29E-09 4.50E-10 3.32E-10 2.51E-10 3.92E-09 3.16E-11 1.23E-11 5.86E-12 4.10E-14 4.60E-13 8.58E-15 4.09E-12 2777 OGC Pipe 6P79C 3.34E-08 8.96E-08 4.01E-12 8.96E-11 3.81E-13 4.81E-09 1.68E-09 1.24E-09 9.39E-10 1.46E-08 1.18E-10 4.61E-11 2.19E-11 1.53E-13 1.72E-12 3.21E-14 1.53E-11 2778 OGC Pipe 6P82 8.94E-08 2.40E-07 1.07E-11 2.40E-10 1.02E-12 1.29E-08 4.50E-09 3.32E-09 2.51E-09 3.92E-08 3.16E-10 1.23E-10 5.86E-11 4.10E-13 4.60E-12 8.58E-14 4.09E-11 2779 OGC Pipe 6P8A 6.22E-08 1.67E-07 7.47E-12 1.67E-10 7.09E-13 8.96E-09 3.13E-09 2.31E-09 1.75E-09 2.73E-08 2.20E-10 8.59E-11 4.08E-11 2.86E-13 3.20E-12 5.97E-14 2.85E-11 2780 OGC Pipe 6P8B 1.30E-06 3.49E-06 1.56E-10 3.49E-09 1.48E-11 1.87E-07 6.55E-08 4.83E-08 3.66E-08 5.70E-07 4.59E-09 1.80E-09 8.53E-10 5.97E-12 6.69E-11 1.25E-12 5.96E-10 2781 OGC Pipe 6P8C 6.22E-08 1.67E-07 7.47E-12 1.67E-10 7.09E-13 8.96E-09 3.13E-09 2.31E-09 1.75E-09 2.73E-08 2.20E-10 8.59E-11 4.08E-11 2.86E-13 3.20E-12 5.97E-14 2.85E-11 2782 OGC Pipe 6S72 1.34E-07 3.59E-07 1.61E-11 3.59E-10 1.53E-12 1.93E-08 6.74E-09 4.97E-09 3.76E-09 5.87E-08 4.73E-10 1.85E-10 8.77E-11 6.15E-13 6.89E-12 1.29E-13 6.14E-11
WVDP-606 Rev. 1 Page 28 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2783 OGC Pipe 6S75 1.34E-07 3.59E-07 1.61E-11 3.59E-10 1.53E-12 1.93E-08 6.74E-09 4.97E-09 3.76E-09 5.87E-08 4.73E-10 1.85E-10 8.77E-11 6.15E-13 6.89E-12 1.29E-13 6.14E-11 2784 OGC Pipe 6SC17 5.35E-07 1.43E-06 6.42E-11 1.43E-09 6.10E-12 7.71E-08 2.69E-08 1.99E-08 1.50E-08 2.34E-07 1.89E-09 7.39E-10 3.51E-10 2.46E-12 2.75E-11 5.14E-13 2.45E-10 2785 OGC Pipe 6SC62 1.34E-07 3.59E-07 1.61E-11 3.59E-10 1.53E-12 1.93E-08 6.74E-09 4.97E-09 3.76E-09 5.87E-08 4.73E-10 1.85E-10 8.77E-11 6.15E-13 6.89E-12 1.29E-13 6.14E-11 2786 OGC Pipe 6UA78 1.01E-07 2.69E-07 1.21E-11 2.69E-10 1.15E-12 1.45E-08 5.06E-09 3.73E-09 2.83E-09 4.40E-08 3.55E-10 1.39E-10 6.59E-11 4.61E-13 5.17E-12 9.65E-14 4.60E-11 2787 OGC Pipe 7CH315 1.96E-08 5.27E-08 2.36E-12 5.27E-11 2.24E-13 2.83E-09 9.88E-10 7.29E-10 5.52E-10 8.61E-09 6.94E-11 2.71E-11 1.29E-11 9.02E-14 1.01E-12 1.89E-14 9.00E-12 2788 OGC Pipe 7P10 3.34E-06 8.96E-06 4.01E-10 8.96E-09 3.81E-11 4.81E-07 1.68E-07 1.24E-07 9.39E-08 1.46E-06 1.18E-08 4.61E-09 2.19E-09 1.53E-11 1.72E-10 3.21E-12 1.53E-09 2789 OGC Pipe 7P10 3.34E-06 8.96E-06 4.01E-10 8.96E-09 3.81E-11 4.81E-07 1.68E-07 1.24E-07 9.39E-08 1.46E-06 1.18E-08 4.61E-09 2.19E-09 1.53E-11 1.72E-10 3.21E-12 1.53E-09 2790 OGC Pipe 7P128 5.95E-07 1.59E-06 7.14E-11 1.59E-09 6.78E-12 8.57E-08 2.99E-08 2.21E-08 1.67E-08 2.61E-07 2.10E-09 8.21E-10 3.90E-10 2.73E-12 3.06E-11 5.71E-13 2.73E-10 2791 OGC Pipe 7P13 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.51E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.10E-12 4.60E-11 8.58E-13 4.09E-10 2792 OGC Pipe 7P13 8.94E-07 2.40E-06 1.07E-10 2.40E-09 1.02E-11 1.29E-07 4.50E-08 3.32E-08 2.51E-08 3.92E-07 3.16E-09 1.23E-09 5.86E-10 4.10E-12 4.60E-11 8.58E-13 4.09E-10 2793 OGC Pipe 7P132 4.46E-08 1.19E-07 5.35E-12 1.19E-10 5.08E-13 6.42E-09 2.24E-09 1.65E-09 1.25E-09 1.95E-08 1.57E-10 6.15E-11 2.92E-11 2.05E-13 2.29E-12 4.28E-14 2.04E-11 2794 OGC Pipe 7P156 7.15E-06 1.92E-05 8.58E-10 1.92E-08 8.15E-11 1.03E-06 3.59E-07 2.65E-07 2.01E-07 3.13E-06 2.52E-08 9.86E-09 4.68E-09 3.28E-11 3.67E-10 6.86E-12 3.27E-09 2795 OGC Pipe 7P240 2.68E-09 7.18E-09 3.22E-13 7.18E-12 3.05E-14 3.86E-10 1.35E-10 9.94E-11 7.53E-11 1.17E-09 9.46E-12 3.70E-12 1.75E-12 1.23E-14 1.38E-13 2.57E-15 1.23E-12 2796 OGC Pipe 7P240 8.94E-10 2.40E-09 1.07E-13 2.40E-12 1.02E-14 1.29E-10 4.50E-11 3.32E-11 2.51E-11 3.92E-10 3.16E-12 1.23E-12 5.86E-13 4.10E-15 4.60E-14 8.58E-16 4.09E-13 2797 OGC Pipe 7P276 1.61E-06 4.31E-06 1.93E-10 4.31E-09 1.83E-11 2.32E-07 8.09E-08 5.97E-08 4.52E-08 7.05E-07 5.68E-09 2.22E-09 1.05E-09 7.38E-12 8.27E-11 1.54E-12 7.37E-10 2798 OGC Pipe 7P276 2.68E-06 7.18E-06 3.22E-10 7.18E-09 3.05E-11 3.86E-07 1.35E-07 9.94E-08 7.53E-08 1.17E-06 9.46E-09 3.70E-09 1.75E-09 1.23E-11 1.38E-10 2.57E-12 1.23E-09 2799 OGC Pipe 7P276 5.35E-07 1.43E-06 6.42E-11 1.43E-09 6.10E-12 7.71E-08 2.69E-08 1.99E-08 1.50E-08 2.34E-07 1.89E-09 7.39E-10 3.51E-10 2.46E-12 2.75E-11 5.14E-13 2.45E-10 2800 OGC Pipe 7P277 3.56E-08 9.54E-08 4.27E-12 9.54E-11 4.06E-13 5.13E-09 1.79E-09 1.32E-09 1.00E-09 1.56E-08 1.26E-10 4.91E-11 2.33E-11 1.63E-13 1.83E-12 3.42E-14 1.63E-11 2801 OGC Pipe 7P277 5.95E-08 1.59E-07 7.14E-12 1.59E-10 6.78E-13 8.57E-09 2.99E-09 2.21E-09 1.67E-09 2.61E-08 2.10E-10 8.21E-11 3.90E-11 2.73E-13 3.06E-12 5.71E-14 2.73E-11 2802 OGC Pipe 7P277 1.19E-08 3.19E-08 1.43E-12 3.19E-11 1.36E-13 1.71E-09 5.99E-10 4.42E-10 3.34E-10 5.21E-09 4.20E-11 1.64E-11 7.80E-12 5.46E-14 6.12E-13 1.14E-14 5.45E-12 925 PCR 144' Ceiling 1.10E-04 4.05E-05 5.46E-09 1.37E-07 3.25E-09 5.80E-06 1.77E-06 1.33E-06 1.00E-06 1.75E-05 1.16E-06 9.10E-08 4.24E-08 1.98E-09 2.85E-08 1.06E-10 5.06E-08 2989 PCR 144' Diverter Box 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 706 PCR 144' E Wall 3.58E-05 1.32E-05 1.77E-09 4.44E-08 1.05E-09 1.88E-06 5.74E-07 4.30E-07 3.24E-07 5.66E-06 3.76E-07 2.95E-08 1.38E-08 6.42E-10 9.25E-09 3.44E-11 1.64E-08 730 PCR 144' Floor 4.92E-05 1.81E-05 2.43E-09 6.10E-08 1.45E-09 2.58E-06 7.88E-07 5.91E-07 4.46E-07 7.78E-06 5.17E-07 4.06E-08 1.89E-08 8.81E-10 1.27E-08 4.73E-11 2.25E-08 723 PCR 144' N Wall 7.15E-06 2.62E-06 3.53E-10 8.86E-09 2.10E-10 3.75E-07 1.14E-07 8.58E-08 6.47E-08 1.13E-06 7.50E-08 5.89E-09 2.74E-09 1.28E-10 1.84E-09 6.86E-12 3.27E-09 725 PCR 144' S Wall 5.71E-05 2.10E-05 2.82E-09 7.08E-08 1.68E-09 3.00E-06 9.14E-07 6.86E-07 5.17E-07 9.03E-06 6.00E-07 4.71E-08 2.19E-08 1.02E-09 1.47E-08 5.48E-11 2.62E-08 731 PCR 144' W Wall 1.08E-05 3.95E-06 5.31E-10 1.33E-08 3.16E-10 5.65E-07 1.72E-07 1.29E-07 9.73E-08 1.70E-06 1.13E-07 8.86E-09 4.13E-09 1.92E-10 2.77E-09 1.03E-11 4.93E-09 1194 PMC Ceiling 5.09E-02 2.64E-02 4.81E-06 8.59E-05 2.59E-08 5.39E-03 1.38E-03 1.11E-03 8.39E-04 8.04E-03 5.34E-06 4.39E-06 2.16E-06 4.26E-07 1.55E-06 4.88E-08 2.33E-05 1192 PMC E Wall Lower 1.14E-01 5.95E-02 1.08E-05 1.93E-04 5.84E-08 1.21E-02 3.10E-03 2.50E-03 1.89E-03 1.81E-02 1.20E-05 9.89E-06 4.87E-06 9.59E-07 3.49E-06 1.10E-07 5.24E-05 1493 PMC E Wall Upper 7.96E-03 4.14E-03 7.52E-07 1.35E-05 4.06E-09 8.44E-04 2.16E-04 1.74E-04 1.31E-04 1.26E-03 8.36E-07 6.88E-07 3.38E-07 6.67E-08 2.43E-07 7.64E-09 3.65E-06 1699 PMC East Rail 1.14E-01 5.92E-02 1.08E-05 1.92E-04 5.80E-08 1.21E-02 3.08E-03 2.48E-03 1.88E-03 1.80E-02 1.20E-05 9.83E-06 4.84E-06 9.54E-07 3.47E-06 1.09E-07 5.21E-05 1190 PMC N Wall Lower 7.30E-03 3.80E-03 6.90E-07 1.23E-05 3.72E-09 7.74E-04 1.98E-04 1.59E-04 1.20E-04 1.15E-03 7.67E-07 6.31E-07 3.10E-07 6.12E-08 2.23E-07 7.01E-09 3.34E-06 1491 PMC N Wall Upper 1.63E-03 8.45E-04 1.54E-07 2.75E-06 8.29E-10 1.72E-04 4.40E-05 3.54E-05 2.68E-05 2.57E-04 1.71E-07 1.40E-07 6.91E-08 1.36E-08 4.96E-08 1.56E-09 7.44E-07 1191 PMC S Wall Lower 5.10E-02 2.65E-02 4.82E-06 8.62E-05 2.60E-08 5.40E-03 1.38E-03 1.11E-03 8.41E-04 8.06E-03 5.35E-06 4.41E-06 2.17E-06 4.27E-07 1.56E-06 4.89E-08 2.34E-05 1492 PMC S Wall Upper 1.53E-03 7.94E-04 1.44E-07 2.58E-06 7.78E-10 1.62E-04 4.14E-05 3.33E-05 2.52E-05 2.41E-04 1.60E-07 1.32E-07 6.49E-08 1.28E-08 4.66E-08 1.47E-09 6.99E-07
WVDP-606 Rev. 1 Page 29 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1193 PMC W Wall Lower 1.18E-01 6.16E-02 1.12E-05 2.00E-04 6.04E-08 1.26E-02 3.21E-03 2.58E-03 1.95E-03 1.87E-02 1.24E-05 1.02E-05 5.03E-06 9.92E-07 3.61E-06 1.14E-07 5.42E-05 1494 PMC W Wall Upper 2.66E-02 1.38E-02 2.51E-06 4.49E-05 1.36E-08 2.82E-03 7.20E-04 5.79E-04 4.39E-04 4.20E-03 2.79E-06 2.30E-06 1.13E-06 2.23E-07 8.11E-07 2.55E-08 1.22E-05 1700 PMC West Rail 1.20E-01 6.26E-02 1.14E-05 2.03E-04 6.14E-08 1.28E-02 3.26E-03 2.62E-03 1.99E-03 1.90E-02 1.26E-05 1.04E-05 5.12E-06 1.01E-06 3.67E-06 1.16E-07 5.51E-05 1118 PMC Penthouse Ceiling 2.40E-03 1.25E-03 2.27E-07 4.06E-06 1.22E-09 2.55E-04 6.51E-05 5.23E-05 3.96E-05 3.79E-04 2.52E-07 2.07E-07 1.02E-07 2.01E-08 7.32E-08 2.31E-09 1.10E-06 1116 PMC Penthouse E Wall 1.67E-03 8.69E-04 1.58E-07 2.82E-06 8.52E-10 1.77E-04 4.53E-05 3.64E-05 2.76E-05 2.64E-04 1.75E-07 1.44E-07 7.10E-08 1.40E-08 5.10E-08 1.60E-09 7.65E-07 1119 PMC Penthouse Floor 3.05E-02 1.59E-02 2.88E-06 5.16E-05 1.56E-08 3.24E-03 8.27E-04 6.65E-04 5.04E-04 4.82E-03 3.21E-06 2.64E-06 1.30E-06 2.56E-07 9.31E-07 2.93E-08 1.40E-05 1114 PMC Penthouse N Wall 5.52E-03 2.87E-03 5.22E-07 9.33E-06 2.82E-09 5.85E-04 1.50E-04 1.20E-04 9.11E-05 8.72E-04 5.80E-07 4.77E-07 2.35E-07 4.63E-08 1.68E-07 5.30E-09 2.53E-06 1115 PMC Penthouse S Wall 1.91E-03 9.96E-04 1.81E-07 3.24E-06 9.76E-10 2.03E-04 5.19E-05 4.17E-05 3.16E-05 3.02E-04 2.01E-07 1.65E-07 8.14E-08 1.60E-08 5.84E-08 1.84E-09 8.77E-07 1117 PMC Penthouse W Wall 1.70E-03 8.83E-04 1.60E-07 2.87E-06 8.66E-10 1.80E-04 4.60E-05 3.70E-05 2.80E-05 2.68E-04 1.78E-07 1.47E-07 7.21E-08 1.42E-08 5.18E-08 1.63E-09 7.77E-07 1124 PMCR Ceiling 9.67E-03 5.03E-03 9.14E-07 1.63E-05 4.93E-09 1.03E-03 2.62E-04 2.11E-04 1.60E-04 1.53E-03 1.02E-06 8.36E-07 4.11E-07 8.10E-08 2.95E-07 9.28E-09 4.43E-06 1122 PMCR E Wall 1.11E-02 5.75E-03 1.04E-06 1.87E-05 5.64E-09 1.17E-03 3.00E-04 2.41E-04 1.82E-04 1.75E-03 1.16E-06 9.55E-07 4.70E-07 9.26E-08 3.37E-07 1.06E-08 5.06E-06 1125 PMCR Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1120 PMCR N Wall 4.17E-03 2.17E-03 3.94E-07 7.05E-06 2.13E-09 4.42E-04 1.13E-04 9.09E-05 6.88E-05 6.59E-04 4.38E-07 3.60E-07 1.77E-07 3.50E-08 1.27E-07 4.00E-09 1.91E-06 1121 PMCR S Wall 3.70E-03 1.93E-03 3.50E-07 6.26E-06 1.89E-09 3.93E-04 1.00E-04 8.07E-05 6.11E-05 5.85E-04 3.89E-07 3.20E-07 1.57E-07 3.10E-08 1.13E-07 3.56E-09 1.70E-06 1123 PMCR W Wall 1.22E-02 6.33E-03 1.15E-06 2.06E-05 6.21E-09 1.29E-03 3.30E-04 2.65E-04 2.01E-04 1.92E-03 1.28E-06 1.05E-06 5.17E-07 1.02E-07 3.71E-07 1.17E-08 5.57E-06 1112 PMCRE Ceiling 4.42E-04 2.30E-04 4.18E-08 7.47E-07 2.25E-10 4.69E-05 1.20E-05 9.64E-06 7.29E-06 6.99E-05 4.64E-08 3.82E-08 1.88E-08 3.70E-09 1.35E-08 4.24E-10 2.02E-07 1110 PMCRE E Wall 6.01E-06 3.13E-06 5.68E-10 1.02E-08 3.07E-12 6.37E-07 1.63E-07 1.31E-07 9.92E-08 9.50E-07 6.31E-10 5.20E-10 2.56E-10 5.04E-11 1.83E-10 5.77E-12 2.75E-09 1113 PMCRE Floor 5.43E-04 2.83E-04 5.14E-08 9.18E-07 2.77E-10 5.76E-05 1.47E-05 1.18E-05 8.97E-06 8.59E-05 5.71E-08 4.70E-08 2.31E-08 4.55E-09 1.66E-08 5.22E-10 2.49E-07 1108 PMCRE N Wall 5.76E-06 3.00E-06 5.45E-10 9.74E-09 2.94E-12 6.11E-07 1.56E-07 1.26E-07 9.51E-08 9.11E-07 6.05E-10 4.98E-10 2.45E-10 4.83E-11 1.76E-10 5.53E-12 2.64E-09 1109 PMCRE S Wall 2.72E-04 1.42E-04 2.57E-08 4.60E-07 1.39E-10 2.89E-05 7.38E-06 5.94E-06 4.49E-06 4.30E-05 2.86E-08 2.35E-08 1.16E-08 2.28E-09 8.31E-09 2.61E-10 1.25E-07 1111 PMCRE W Wall 2.16E-05 1.13E-05 2.05E-09 3.66E-08 1.10E-11 2.29E-06 5.87E-07 4.72E-07 3.57E-07 3.42E-06 2.27E-09 1.87E-09 9.20E-10 1.81E-10 6.60E-10 2.08E-11 9.91E-09 555 PPC-N Ceiling 2.55E-05 1.49E-04 3.55E-07 7.51E-06 3.27E-06 2.96E-02 9.38E-03 7.72E-03 5.90E-03 9.40E-02 1.77E-04 5.52E-05 2.68E-05 1.60E-06 2.04E-06 2.45E-11 1.17E-08 553 PPC-N E Wall 4.79E-06 2.80E-05 6.66E-08 1.41E-06 6.13E-07 5.55E-03 1.76E-03 1.45E-03 1.11E-03 1.76E-02 3.32E-05 1.03E-05 5.03E-06 2.99E-07 3.83E-07 4.60E-12 2.19E-09 552 PPC-N N Wall 1.32E-04 1.25E-03 1.85E-06 4.08E-05 1.52E-05 2.24E-02 6.48E-03 5.39E-03 4.12E-03 9.39E-02 1.07E-04 7.17E-05 3.43E-05 2.23E-06 3.47E-05 1.27E-10 6.05E-08 554 PPC-N S Wall 3.37E-05 1.97E-04 4.69E-07 9.91E-06 4.32E-06 3.91E-02 1.24E-02 1.02E-02 7.79E-03 1.24E-01 2.34E-04 7.28E-05 3.54E-05 2.11E-06 2.69E-06 3.24E-11 1.54E-08 556 PPC-N W Wall 8.61E-05 8.14E-04 1.21E-06 2.66E-05 9.90E-06 1.46E-02 4.23E-03 3.51E-03 2.69E-03 6.12E-02 7.00E-05 4.68E-05 2.24E-05 1.46E-06 2.27E-05 8.27E-11 3.94E-08 2633 PPC-N Pipe 15J1302 7.87E-10 7.43E-09 1.10E-11 2.43E-10 9.05E-11 1.34E-07 3.86E-08 3.21E-08 2.45E-08 5.59E-07 6.40E-10 4.27E-10 2.05E-10 1.33E-11 2.07E-10 7.55E-16 3.60E-13 2634 PPC-N Pipe 15J1319 5.24E-10 4.96E-09 7.34E-12 1.62E-10 6.03E-11 8.91E-08 2.57E-08 2.14E-08 1.64E-08 3.73E-07 4.26E-10 2.85E-10 1.36E-10 8.86E-12 1.38E-10 5.03E-16 2.40E-13 2635 PPC-N Pipe 15J933 1.57E-07 1.48E-06 2.20E-09 4.85E-08 1.80E-08 2.67E-05 7.71E-06 6.40E-06 4.90E-06 1.12E-04 1.28E-07 8.52E-08 4.08E-08 2.65E-09 4.13E-08 1.51E-13 7.19E-11 2636 PPC-N Pipe 15P1355 8.33E-09 7.88E-08 1.17E-10 2.58E-09 9.59E-10 1.42E-06 4.09E-07 3.40E-07 2.60E-07 5.93E-06 6.78E-09 4.53E-09 2.17E-09 1.41E-10 2.19E-09 8.00E-15 3.82E-12 2637 PPC-N Pipe 15P1356 1.26E-08 1.19E-07 1.77E-10 3.90E-09 1.45E-09 2.15E-06 6.20E-07 5.15E-07 3.94E-07 8.98E-06 1.03E-08 6.86E-09 3.28E-09 2.13E-10 3.32E-09 1.21E-14 5.79E-12 2638 PPC-N Pipe 15P1365 5.24E-11 4.96E-10 7.34E-13 1.62E-11 6.03E-12 8.91E-09 2.57E-09 2.14E-09 1.64E-09 3.73E-08 4.26E-11 2.85E-11 1.36E-11 8.86E-13 1.38E-11 5.03E-17 2.40E-14 2639 PPC-N Pipe 15S720 4.72E-09 4.46E-08 6.60E-11 1.46E-09 5.43E-10 8.02E-07 2.32E-07 1.92E-07 1.47E-07 3.35E-06 3.84E-09 2.56E-09 1.23E-09 7.97E-11 1.24E-09 4.53E-15 2.16E-12 2640 PPC-N Pipe 15V1089 8.49E-09 8.02E-08 1.19E-10 2.62E-09 9.76E-10 1.44E-06 4.17E-07 3.46E-07 2.65E-07 6.03E-06 6.90E-09 4.61E-09 2.21E-09 1.43E-10 2.23E-09 8.15E-15 3.89E-12 2641 PPC-N Pipe 15V947 8.97E-09 8.47E-08 1.26E-10 2.77E-09 1.03E-09 1.52E-06 4.40E-07 3.66E-07 2.80E-07 6.38E-06 7.29E-09 4.87E-09 2.33E-09 1.52E-10 2.36E-09 8.61E-15 4.11E-12
WVDP-606 Rev. 1 Page 30 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2642 PPC-N Pipe 5CH588 2.62E-07 2.48E-06 3.67E-09 8.10E-08 3.02E-08 4.46E-05 1.29E-05 1.07E-05 8.18E-06 1.86E-04 2.13E-07 1.42E-07 6.82E-08 4.43E-09 6.90E-08 2.52E-13 1.20E-10 2643 PPC-N Pipe 5CH92 1.73E-10 1.64E-09 2.42E-12 5.35E-11 1.99E-11 2.94E-08 8.50E-09 7.07E-09 5.40E-09 1.23E-07 1.41E-10 9.41E-11 4.50E-11 2.93E-12 4.56E-11 1.66E-16 7.93E-14 2644 PPC-N Pipe 5CW189 1.42E-06 1.34E-05 1.98E-08 4.38E-07 1.63E-07 2.41E-04 6.95E-05 5.78E-05 4.42E-05 1.01E-03 1.15E-06 7.69E-07 3.68E-07 2.39E-08 3.72E-07 1.36E-12 6.49E-10 2645 PPC-N Pipe 5CW190 6.60E-07 6.24E-06 9.24E-09 2.04E-07 7.59E-08 1.12E-04 3.24E-05 2.69E-05 2.06E-05 4.69E-04 5.37E-07 3.59E-07 1.72E-07 1.12E-08 1.74E-07 6.34E-13 3.02E-10 2646 PPC-N Pipe 5CW216 9.07E-10 8.57E-09 1.27E-11 2.80E-10 1.04E-10 1.54E-07 4.45E-08 3.70E-08 2.83E-08 6.45E-07 7.38E-10 4.93E-10 2.36E-10 1.53E-11 2.39E-10 8.71E-16 4.15E-13 2647 PPC-N Pipe 5CW216 1.51E-09 1.43E-08 2.12E-11 4.67E-10 1.74E-10 2.57E-07 7.42E-08 6.17E-08 4.72E-08 1.08E-06 1.23E-09 8.21E-10 3.93E-10 2.56E-11 3.98E-10 1.45E-15 6.92E-13 2648 PPC-N Pipe 5CW217 3.63E-09 3.43E-08 5.08E-11 1.12E-09 4.17E-10 6.17E-07 1.78E-07 1.48E-07 1.13E-07 2.58E-06 2.95E-09 1.97E-09 9.43E-10 6.13E-11 9.54E-10 3.48E-15 1.66E-12 2649 PPC-N Pipe 5DW166 2.50E-09 2.36E-08 3.50E-11 7.72E-10 2.87E-10 4.25E-07 1.23E-07 1.02E-07 7.79E-08 1.78E-06 2.03E-09 1.36E-09 6.49E-10 4.22E-11 6.57E-10 2.40E-15 1.14E-12 2650 PPC-N Pipe 5DW167 3.33E-09 3.15E-08 4.66E-11 1.03E-09 3.83E-10 5.66E-07 1.64E-07 1.36E-07 1.04E-07 2.37E-06 2.71E-09 1.81E-09 8.66E-10 5.63E-11 8.76E-10 3.20E-15 1.53E-12 2651 PPC-N Pipe 5DW168 8.33E-10 7.88E-09 1.17E-11 2.58E-10 9.59E-11 1.42E-07 4.09E-08 3.40E-08 2.60E-08 5.93E-07 6.78E-10 4.53E-10 2.17E-10 1.41E-11 2.19E-10 8.00E-16 3.82E-13 2652 PPC-N Pipe 5DW172 2.09E-09 1.97E-08 2.92E-11 6.45E-10 2.40E-10 3.55E-07 1.02E-07 8.51E-08 6.51E-08 1.48E-06 1.70E-09 1.13E-09 5.42E-10 3.53E-11 5.49E-10 2.00E-15 9.55E-13 2653 PPC-N Pipe 5IA152 1.57E-08 1.48E-07 2.20E-10 4.85E-09 1.80E-09 2.67E-06 7.71E-07 6.40E-07 4.90E-07 1.12E-05 1.28E-08 8.52E-09 4.08E-09 2.65E-10 4.13E-09 1.51E-14 7.19E-12 2654 PPC-N Pipe 5IA152 2.62E-08 2.48E-07 3.67E-10 8.10E-09 3.02E-09 4.46E-06 1.29E-06 1.07E-06 8.18E-07 1.86E-05 2.13E-08 1.42E-08 6.82E-09 4.43E-10 6.90E-09 2.52E-14 1.20E-11 2655 PPC-N Pipe 5IA156 2.62E-07 2.48E-06 3.67E-09 8.10E-08 3.02E-08 4.46E-05 1.29E-05 1.07E-05 8.18E-06 1.86E-04 2.13E-07 1.42E-07 6.82E-08 4.43E-09 6.90E-08 2.52E-13 1.20E-10 2656 PPC-N Pipe 5IA220 2.62E-11 2.48E-10 3.67E-13 8.10E-12 3.02E-12 4.46E-09 1.29E-09 1.07E-09 8.18E-10 1.86E-08 2.13E-11 1.42E-11 6.82E-12 4.43E-13 6.90E-12 2.52E-17 1.20E-14 2657 PPC-N Pipe 5IA221 7.87E-08 7.43E-07 1.10E-09 2.43E-08 9.05E-09 1.34E-05 3.86E-06 3.21E-06 2.45E-06 5.59E-05 6.40E-08 4.27E-08 2.05E-08 1.33E-09 2.07E-08 7.55E-14 3.60E-11 2658 PPC-N Pipe 5IA258 1.57E-11 1.48E-10 2.20E-13 4.85E-12 1.80E-12 2.67E-09 7.71E-10 6.40E-10 4.90E-10 1.12E-08 1.28E-11 8.52E-12 4.08E-12 2.65E-13 4.13E-12 1.51E-17 7.19E-15 2659 PPC-N Pipe 5IA258 2.62E-11 2.48E-10 3.67E-13 8.10E-12 3.02E-12 4.46E-09 1.29E-09 1.07E-09 8.18E-10 1.86E-08 2.13E-11 1.42E-11 6.82E-12 4.43E-13 6.90E-12 2.52E-17 1.20E-14 2660 PPC-N Pipe 5IA270 2.62E-09 2.48E-08 3.67E-11 8.10E-10 3.02E-10 4.46E-07 1.29E-07 1.07E-07 8.18E-08 1.86E-06 2.13E-09 1.42E-09 6.82E-10 4.43E-11 6.90E-10 2.52E-15 1.20E-12 2661 PPC-N Pipe 5IA338 2.62E-11 2.48E-10 3.67E-13 8.10E-12 3.02E-12 4.46E-09 1.29E-09 1.07E-09 8.18E-10 1.86E-08 2.13E-11 1.42E-11 6.82E-12 4.43E-13 6.90E-12 2.52E-17 1.20E-14 2662 PPC-N Pipe 5J240A 3.15E-08 2.98E-07 4.41E-10 9.73E-09 3.62E-09 5.35E-06 1.55E-06 1.28E-06 9.82E-07 2.24E-05 2.56E-08 1.71E-08 8.19E-09 5.32E-10 8.28E-09 3.02E-14 1.44E-11 2663 PPC-N Pipe 5J240A 5.24E-08 4.96E-07 7.34E-10 1.62E-08 6.03E-09 8.91E-06 2.57E-06 2.14E-06 1.64E-06 3.73E-05 4.26E-08 2.85E-08 1.36E-08 8.86E-10 1.38E-08 5.03E-14 2.40E-11 2664 PPC-N Pipe 5J240B 3.15E-08 2.98E-07 4.41E-10 9.73E-09 3.62E-09 5.35E-06 1.55E-06 1.28E-06 9.82E-07 2.24E-05 2.56E-08 1.71E-08 8.19E-09 5.32E-10 8.28E-09 3.02E-14 1.44E-11 2665 PPC-N Pipe 5J240B 5.24E-08 4.96E-07 7.34E-10 1.62E-08 6.03E-09 8.91E-06 2.57E-06 2.14E-06 1.64E-06 3.73E-05 4.26E-08 2.85E-08 1.36E-08 8.86E-10 1.38E-08 5.03E-14 2.40E-11 2666 PPC-N Pipe 5J241A 2.62E-09 2.48E-08 3.67E-11 8.10E-10 3.02E-10 4.46E-07 1.29E-07 1.07E-07 8.18E-08 1.86E-06 2.13E-09 1.42E-09 6.82E-10 4.43E-11 6.90E-10 2.52E-15 1.20E-12 2667 PPC-N Pipe 5J241B 2.62E-09 2.48E-08 3.67E-11 8.10E-10 3.02E-10 4.46E-07 1.29E-07 1.07E-07 8.18E-08 1.86E-06 2.13E-09 1.42E-09 6.82E-10 4.43E-11 6.90E-10 2.52E-15 1.20E-12 2668 PPC-N Pipe 5J241C 2.62E-09 2.48E-08 3.67E-11 8.10E-10 3.02E-10 4.46E-07 1.29E-07 1.07E-07 8.18E-08 1.86E-06 2.13E-09 1.42E-09 6.82E-10 4.43E-11 6.90E-10 2.52E-15 1.20E-12 2669 PPC-N Pipe 5P11 4.75E-09 4.49E-08 6.64E-11 1.47E-09 5.46E-10 8.07E-07 2.33E-07 1.94E-07 1.48E-07 3.37E-06 3.86E-09 2.58E-09 1.23E-09 8.02E-11 1.25E-09 4.56E-15 2.17E-12 2670 PPC-N Pipe 5P204 1.18E-07 1.11E-06 1.65E-09 3.64E-08 1.35E-08 2.00E-05 5.78E-06 4.80E-06 3.67E-06 8.37E-05 9.57E-08 6.39E-08 3.06E-08 1.99E-09 3.10E-08 1.13E-13 5.39E-11 2671 PPC-N Pipe 5P222A 3.67E-11 3.46E-10 5.13E-13 1.13E-11 4.21E-12 6.23E-09 1.80E-09 1.50E-09 1.14E-09 2.61E-08 2.98E-11 1.99E-11 9.53E-12 6.19E-13 9.64E-12 3.52E-17 1.68E-14 2672 PPC-N Pipe 5P222B 9.18E-12 8.67E-11 1.28E-13 2.84E-12 1.06E-12 1.56E-09 4.51E-10 3.74E-10 2.86E-10 6.52E-09 7.46E-12 4.98E-12 2.39E-12 1.55E-13 2.41E-12 8.81E-18 4.20E-15 2673 PPC-N Pipe 5P222C 9.18E-12 8.67E-11 1.28E-13 2.84E-12 1.06E-12 1.56E-09 4.51E-10 3.74E-10 2.86E-10 6.52E-09 7.46E-12 4.98E-12 2.39E-12 1.55E-13 2.41E-12 8.81E-18 4.20E-15 2674 PPC-N Pipe 5P249 3.28E-09 3.10E-08 4.60E-11 1.01E-09 3.77E-10 5.58E-07 1.61E-07 1.34E-07 1.02E-07 2.33E-06 2.67E-09 1.78E-09 8.53E-10 5.55E-11 8.63E-10 3.15E-15 1.50E-12 2675 PPC-N Pipe 5P253 5.67E-08 5.35E-07 7.93E-10 1.75E-08 6.51E-09 9.63E-06 2.78E-06 2.31E-06 1.77E-06 4.03E-05 4.61E-08 3.08E-08 1.47E-08 9.57E-10 1.49E-08 5.44E-14 2.59E-11 2676 PPC-N Pipe 5P330 1.10E-05 1.04E-04 1.54E-07 3.40E-06 1.27E-06 1.87E-03 5.40E-04 4.49E-04 3.43E-04 7.82E-03 8.95E-06 5.98E-06 2.86E-06 1.86E-07 2.89E-06 1.06E-11 5.04E-09
WVDP-606 Rev. 1 Page 31 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2677 PPC-N Pipe 5P367 9.86E-06 9.31E-05 1.38E-07 3.05E-06 1.13E-06 1.68E-03 4.84E-04 4.02E-04 3.08E-04 7.01E-03 8.01E-06 5.35E-06 2.56E-06 1.67E-07 2.59E-06 9.46E-12 4.51E-09 2678 PPC-N Pipe 5P367 1.64E-05 1.55E-04 2.29E-07 5.06E-06 1.88E-06 2.78E-03 8.03E-04 6.68E-04 5.11E-04 1.16E-02 1.33E-05 8.89E-06 4.25E-06 2.77E-07 4.30E-06 1.57E-11 7.49E-09 2679 PPC-N Pipe 5P368 8.19E-08 7.74E-07 1.15E-09 2.53E-08 9.42E-09 1.39E-05 4.02E-06 3.34E-06 2.56E-06 5.82E-05 6.66E-08 4.45E-08 2.13E-08 1.38E-09 2.15E-08 7.86E-14 3.75E-11 2680 PPC-N Pipe 5P368 3.93E-08 3.72E-07 5.51E-10 1.22E-08 4.52E-09 6.69E-06 1.93E-06 1.60E-06 1.23E-06 2.80E-05 3.20E-08 2.14E-08 1.02E-08 6.65E-10 1.03E-08 3.78E-14 1.80E-11 2681 PPC-N Pipe 5P370 1.64E-06 1.55E-05 2.29E-08 5.06E-07 1.88E-07 2.78E-04 8.03E-05 6.68E-05 5.11E-05 1.16E-03 1.33E-06 8.89E-07 4.25E-07 2.77E-08 4.30E-07 1.57E-12 7.49E-10 2682 PPC-N Pipe 5P370 6.56E-06 6.19E-05 9.18E-08 2.03E-06 7.54E-07 1.11E-03 3.22E-04 2.67E-04 2.05E-04 4.66E-03 5.33E-06 3.56E-06 1.70E-06 1.11E-07 1.72E-06 6.29E-12 3.00E-09 2683 PPC-N Pipe 5P376 6.56E-08 6.19E-07 9.18E-10 2.03E-08 7.54E-09 1.11E-05 3.22E-06 2.67E-06 2.05E-06 4.66E-05 5.33E-08 3.56E-08 1.70E-08 1.11E-09 1.72E-08 6.29E-14 3.00E-11 2684 PPC-N Pipe 5P379 1.05E-07 9.95E-07 1.47E-09 3.25E-08 1.21E-08 1.79E-05 5.17E-06 4.29E-06 3.28E-06 7.48E-05 8.56E-08 5.72E-08 2.74E-08 1.78E-09 2.77E-08 1.01E-13 4.82E-11 2685 PPC-N Pipe 5P383 3.27E-08 3.09E-07 4.58E-10 1.01E-08 3.76E-09 5.56E-06 1.61E-06 1.34E-06 1.02E-06 2.33E-05 2.66E-08 1.78E-08 8.51E-09 5.53E-10 8.61E-09 3.14E-14 1.50E-11 2686 PPC-N Pipe 5P392 2.62E-09 2.48E-08 3.67E-11 8.10E-10 3.02E-10 4.46E-07 1.29E-07 1.07E-07 8.18E-08 1.86E-06 2.13E-09 1.42E-09 6.82E-10 4.43E-11 6.90E-10 2.52E-15 1.20E-12 2687 PPC-N Pipe 5P402 2.36E-05 2.23E-04 3.31E-07 7.30E-06 2.72E-06 4.02E-03 1.16E-03 9.64E-04 7.37E-04 1.68E-02 1.92E-05 1.28E-05 6.15E-06 3.99E-07 6.22E-06 2.27E-11 1.08E-08 2688 PPC-N Pipe 5P51 1.67E-07 1.57E-06 2.33E-09 5.15E-08 1.91E-08 2.83E-05 8.18E-06 6.79E-06 5.20E-06 1.18E-04 1.35E-07 9.04E-08 4.33E-08 2.81E-09 4.38E-08 1.60E-13 7.63E-11 2689 PPC-N Pipe 5P51 1.20E-07 1.13E-06 1.67E-09 3.70E-08 1.38E-08 2.03E-05 5.87E-06 4.88E-06 3.73E-06 8.50E-05 9.72E-08 6.50E-08 3.11E-08 2.02E-09 3.15E-08 1.15E-13 5.48E-11 2690 PPC-N Pipe 5P52 3.67E-08 3.46E-07 5.13E-10 1.13E-08 4.21E-09 6.23E-06 1.80E-06 1.50E-06 1.14E-06 2.61E-05 2.98E-08 1.99E-08 9.53E-09 6.19E-10 9.64E-09 3.52E-14 1.68E-11 2691 PPC-N Pipe 5P53 9.45E-09 8.93E-08 1.32E-10 2.92E-09 1.09E-09 1.61E-06 4.64E-07 3.86E-07 2.95E-07 6.72E-06 7.69E-09 5.13E-09 2.46E-09 1.60E-10 2.49E-09 9.08E-15 4.33E-12 2692 PPC-N Pipe 5P54 3.36E-08 3.17E-07 4.70E-10 1.04E-08 3.86E-09 5.71E-06 1.65E-06 1.37E-06 1.05E-06 2.39E-05 2.73E-08 1.82E-08 8.73E-09 5.68E-10 8.83E-09 3.22E-14 1.54E-11 2693 PPC-N Pipe 5P62 1.26E-08 1.19E-07 1.77E-10 3.90E-09 1.45E-09 2.15E-06 6.20E-07 5.15E-07 3.94E-07 8.98E-06 1.03E-08 6.86E-09 3.28E-09 2.13E-10 3.32E-09 1.21E-14 5.79E-12 2694 PPC-N Pipe 5P64 5.04E-08 4.77E-07 7.06E-10 1.56E-08 5.80E-09 8.57E-06 2.48E-06 2.06E-06 1.57E-06 3.59E-05 4.10E-08 2.74E-08 1.31E-08 8.52E-10 1.33E-08 4.84E-14 2.31E-11 2695 PPC-N Pipe 5P649 4.04E-08 3.82E-07 5.65E-10 1.25E-08 4.64E-09 6.87E-06 1.98E-06 1.65E-06 1.26E-06 2.87E-05 3.28E-08 2.19E-08 1.05E-08 6.82E-10 1.06E-08 3.88E-14 1.85E-11 2696 PPC-N Pipe 5P71 3.78E-09 3.57E-08 5.29E-11 1.17E-09 4.35E-10 6.43E-07 1.86E-07 1.54E-07 1.18E-07 2.69E-06 3.07E-09 2.05E-09 9.83E-10 6.39E-11 9.94E-10 3.63E-15 1.73E-12 2697 PPC-N Pipe 5P72 1.96E-08 1.85E-07 2.75E-10 6.06E-09 2.26E-09 3.33E-06 9.63E-07 8.00E-07 6.12E-07 1.39E-05 1.59E-08 1.07E-08 5.10E-09 3.32E-10 5.16E-09 1.88E-14 8.98E-12 2698 PPC-N Pipe 5P73 1.95E-08 1.84E-07 2.73E-10 6.03E-09 2.24E-09 3.32E-06 9.59E-07 7.96E-07 6.09E-07 1.39E-05 1.59E-08 1.06E-08 5.08E-09 3.30E-10 5.13E-09 1.87E-14 8.94E-12 2699 PPC-N Pipe 5P74 3.02E-09 2.86E-08 4.23E-11 9.34E-10 3.48E-10 5.14E-07 1.48E-07 1.23E-07 9.43E-08 2.15E-06 2.46E-09 1.64E-09 7.86E-10 5.11E-11 7.95E-10 2.90E-15 1.38E-12 2700 PPC-N Pipe 5P75 2.52E-09 2.38E-08 3.52E-11 7.78E-10 2.89E-10 4.28E-07 1.24E-07 1.03E-07 7.85E-08 1.79E-06 2.05E-09 1.37E-09 6.54E-10 4.25E-11 6.62E-10 2.42E-15 1.15E-12 2701 PPC-N Pipe 5P81 8.82E-09 8.34E-08 1.24E-10 2.73E-09 1.01E-09 1.50E-06 4.33E-07 3.60E-07 2.75E-07 6.27E-06 7.17E-09 4.79E-09 2.29E-09 1.49E-10 2.32E-09 8.47E-15 4.04E-12 2702 PPC-N Pipe 5P90 3.24E-09 3.07E-08 4.54E-11 1.00E-09 3.73E-10 5.51E-07 1.59E-07 1.32E-07 1.01E-07 2.31E-06 2.64E-09 1.76E-09 8.43E-10 5.48E-11 8.53E-10 3.11E-15 1.49E-12 2703 PPC-N Pipe 5P95 3.27E-08 3.09E-07 4.58E-10 1.01E-08 3.76E-09 5.56E-06 1.61E-06 1.34E-06 1.02E-06 2.33E-05 2.66E-08 1.78E-08 8.51E-09 5.53E-10 8.61E-09 3.14E-14 1.50E-11 2704 PPC-N Pipe 5UA193 1.42E-07 1.34E-06 1.98E-09 4.38E-08 1.63E-08 2.41E-05 6.95E-06 5.78E-06 4.42E-06 1.01E-04 1.15E-07 7.69E-08 3.68E-08 2.39E-09 3.72E-08 1.36E-13 6.49E-11 2705 PPC-N Pipe 5UA210 1.57E-08 1.48E-07 2.20E-10 4.85E-09 1.80E-09 2.67E-06 7.71E-07 6.40E-07 4.90E-07 1.12E-05 1.28E-08 8.52E-09 4.08E-09 2.65E-10 4.13E-09 1.51E-14 7.19E-12 2706 PPC-N Pipe 5UA210 2.62E-08 2.48E-07 3.67E-10 8.10E-09 3.02E-09 4.46E-06 1.29E-06 1.07E-06 8.18E-07 1.86E-05 2.13E-08 1.42E-08 6.82E-09 4.43E-10 6.90E-09 2.52E-14 1.20E-11 2707 PPC-N Pipe 5UA522 1.31E-08 1.24E-07 1.84E-10 4.05E-09 1.51E-09 2.23E-06 6.44E-07 5.35E-07 4.09E-07 9.32E-06 1.07E-08 7.12E-09 3.41E-09 2.22E-10 3.45E-09 1.26E-14 6.00E-12 2708 PPC-N Pipe 6-71-095 3.15E-06 2.98E-05 4.41E-08 9.73E-07 3.62E-07 5.35E-04 1.55E-04 1.28E-04 9.82E-05 2.24E-03 2.56E-06 1.71E-06 8.19E-07 5.32E-08 8.28E-07 3.02E-12 1.44E-09 2709 PPC-N Pipe 6-71-110 1.31E-06 1.24E-05 1.84E-08 4.05E-07 1.51E-07 2.23E-04 6.44E-05 5.35E-05 4.09E-05 9.32E-04 1.07E-06 7.12E-07 3.41E-07 2.22E-08 3.45E-07 1.26E-12 6.00E-10 2710 PPC-N Pipe 6-71-135 6.29E-06 5.94E-05 8.80E-08 1.94E-06 7.23E-07 1.07E-03 3.09E-04 2.57E-04 1.96E-04 4.47E-03 5.11E-06 3.41E-06 1.63E-06 1.06E-07 1.65E-06 6.04E-12 2.88E-09 2711 PPC-N Pipe 6-71-136 3.46E-08 3.27E-07 4.85E-10 1.07E-08 3.98E-09 5.89E-06 1.70E-06 1.41E-06 1.08E-06 2.46E-05 2.82E-08 1.88E-08 9.01E-09 5.85E-10 9.11E-09 3.33E-14 1.59E-11
WVDP-606 Rev. 1 Page 32 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2712 PPC-N Pipe 6-71-138 1.57E-06 1.48E-05 2.20E-08 4.85E-07 1.80E-07 2.67E-04 7.71E-05 6.40E-05 4.90E-05 1.12E-03 1.28E-06 8.52E-07 4.08E-07 2.65E-08 4.13E-07 1.51E-12 7.19E-10 2713 PPC-N Pipe 6-71-203 7.55E-13 7.13E-12 1.06E-14 2.33E-13 8.68E-14 1.28E-10 3.71E-11 3.08E-11 2.36E-11 5.37E-10 6.14E-13 4.10E-13 1.96E-13 1.28E-14 1.99E-13 7.25E-19 3.46E-16 2714 PPC-N Pipe 6-71-308 2.10E-09 1.98E-08 2.93E-11 6.48E-10 2.41E-10 3.56E-07 1.03E-07 8.55E-08 6.54E-08 1.49E-06 1.70E-09 1.14E-09 5.45E-10 3.54E-11 5.51E-10 2.01E-15 9.60E-13 2715 PPC-N Pipe 6-71-313 3.15E-07 2.98E-06 4.41E-09 9.73E-08 3.62E-08 5.35E-05 1.55E-05 1.28E-05 9.82E-06 2.24E-04 2.56E-07 1.71E-07 8.19E-08 5.32E-09 8.28E-08 3.02E-13 1.44E-10 2716 PPC-N Pipe 6-71-314 3.15E-08 2.98E-07 4.41E-10 9.73E-09 3.62E-09 5.35E-06 1.55E-06 1.28E-06 9.82E-07 2.24E-05 2.56E-08 1.71E-08 8.19E-09 5.32E-10 8.28E-09 3.02E-14 1.44E-11 2717 PPC-N Pipe 6-71-390 3.15E-08 2.98E-07 4.41E-10 9.73E-09 3.62E-09 5.35E-06 1.55E-06 1.28E-06 9.82E-07 2.24E-05 2.56E-08 1.71E-08 8.19E-09 5.32E-10 8.28E-09 3.02E-14 1.44E-11 2718 PPC-N Pipe 6-71-438 1.05E-09 9.95E-09 1.47E-11 3.25E-10 1.21E-10 1.79E-07 5.17E-08 4.29E-08 3.28E-08 7.48E-07 8.56E-10 5.72E-10 2.74E-10 1.78E-11 2.77E-10 1.01E-15 4.82E-13 2719 PPC-N Pipe 6-71-444 1.05E-11 9.95E-11 1.47E-13 3.25E-12 1.21E-12 1.79E-09 5.17E-10 4.29E-10 3.28E-10 7.48E-09 8.56E-12 5.72E-12 2.74E-12 1.78E-13 2.77E-12 1.01E-17 4.82E-15 2720 PPC-N Pipe 6-71-448 1.05E-09 9.95E-09 1.47E-11 3.25E-10 1.21E-10 1.79E-07 5.17E-08 4.29E-08 3.28E-08 7.48E-07 8.56E-10 5.72E-10 2.74E-10 1.78E-11 2.77E-10 1.01E-15 4.82E-13 2721 PPC-N Pipe 6-71-452 2.10E-08 1.98E-07 2.93E-10 6.48E-09 2.41E-09 3.56E-06 1.03E-06 8.55E-07 6.54E-07 1.49E-05 1.70E-08 1.14E-08 5.45E-09 3.54E-10 5.51E-09 2.01E-14 9.60E-12 2722 PPC-N Pipe 6-71-631 1.05E-08 9.95E-08 1.47E-10 3.25E-09 1.21E-09 1.79E-06 5.17E-07 4.29E-07 3.28E-07 7.48E-06 8.56E-09 5.72E-09 2.74E-09 1.78E-10 2.77E-09 1.01E-14 4.82E-12 2723 PPC-N Pipe 6-71-632 5.24E-09 4.96E-08 7.34E-11 1.62E-09 6.03E-10 8.91E-07 2.57E-07 2.14E-07 1.64E-07 3.73E-06 4.26E-09 2.85E-09 1.36E-09 8.86E-11 1.38E-09 5.03E-15 2.40E-12 2724 PPC-N Pipe 6-71-633 2.62E-07 2.48E-06 3.67E-09 8.10E-08 3.02E-08 4.46E-05 1.29E-05 1.07E-05 8.18E-06 1.86E-04 2.13E-07 1.42E-07 6.82E-08 4.43E-09 6.90E-08 2.52E-13 1.20E-10 2725 PPC-N Pipe 6-71-699 7.87E-08 7.43E-07 1.10E-09 2.43E-08 9.05E-09 1.34E-05 3.86E-06 3.21E-06 2.45E-06 5.59E-05 6.40E-08 4.27E-08 2.05E-08 1.33E-09 2.07E-08 7.55E-14 3.60E-11 2727 PPC-N Pipe Vent 6.56E-09 6.19E-08 9.18E-11 2.03E-09 7.54E-10 1.11E-06 3.22E-07 2.67E-07 2.05E-07 4.66E-06 5.33E-09 3.56E-09 1.70E-09 1.11E-10 1.72E-09 6.29E-15 3.00E-12 558 PPC-S Ceiling 3.07E-05 1.79E-04 4.26E-07 9.01E-06 3.92E-06 3.56E-02 1.13E-02 9.26E-03 7.08E-03 1.13E-01 2.13E-04 6.62E-05 3.22E-05 1.92E-06 2.45E-06 2.94E-11 1.40E-08 557 PPC-S E Wall Lower 2.69E-06 1.57E-05 3.73E-08 7.90E-07 3.44E-07 3.12E-03 9.86E-04 8.11E-04 6.20E-04 9.88E-03 1.86E-05 5.80E-06 2.82E-06 1.68E-07 2.15E-07 2.58E-12 1.23E-09 1186 PPC-S E Wall Upper 7.15E-06 4.18E-05 9.94E-08 2.10E-06 9.16E-07 8.30E-03 2.63E-03 2.16E-03 1.65E-03 2.63E-02 4.96E-05 1.55E-05 7.51E-06 4.47E-07 5.72E-07 6.87E-12 3.28E-09 561 PPC-S N Wall Lower 8.41E-05 4.92E-04 1.17E-06 2.47E-05 1.08E-05 9.75E-02 3.09E-02 2.54E-02 1.94E-02 3.09E-01 5.84E-04 1.82E-04 8.83E-05 5.26E-06 6.72E-06 8.07E-11 3.85E-08 1183 PPC-S N Wall Upper 2.95E-04 1.73E-03 4.10E-06 8.67E-05 3.77E-05 3.42E-01 1.08E-01 8.91E-02 6.81E-02 1.09E+00 2.05E-03 6.37E-04 3.10E-04 1.84E-05 2.36E-05 2.83E-10 1.35E-07 560 PPC-S S Wall Lower 1.24E-04 7.28E-04 1.73E-06 3.66E-05 1.59E-05 1.44E-01 4.56E-02 3.76E-02 2.87E-02 4.58E-01 8.63E-04 2.69E-04 1.31E-04 7.77E-06 9.94E-06 1.19E-10 5.70E-08 1184 PPC-S S Wall Upper 8.32E-05 4.87E-04 1.16E-06 2.45E-05 1.07E-05 9.65E-02 3.05E-02 2.51E-02 1.92E-02 3.06E-01 5.77E-04 1.80E-04 8.74E-05 5.20E-06 6.65E-06 7.99E-11 3.81E-08 1185 PPC-S S Wall Upper Stain 4.38E-04 2.56E-03 6.09E-06 1.29E-04 5.61E-05 5.08E-01 1.61E-01 1.32E-01 1.01E-01 1.61E+00 3.04E-03 9.46E-04 4.60E-04 2.74E-05 3.50E-05 4.20E-10 2.01E-07 559 PPC-S W Wall Lower 2.69E-06 1.57E-05 3.73E-08 7.90E-07 3.44E-07 3.12E-03 9.86E-04 8.11E-04 6.20E-04 9.88E-03 1.86E-05 5.80E-06 2.82E-06 1.68E-07 2.15E-07 2.58E-12 1.23E-09 1187 PPC-S W Wall Upper 7.15E-06 4.18E-05 9.94E-08 2.10E-06 9.16E-07 8.30E-03 2.63E-03 2.16E-03 1.65E-03 2.63E-02 4.96E-05 1.55E-05 7.51E-06 4.47E-07 5.72E-07 6.87E-12 3.28E-09 2536 PPC-S Pipe 15J1302 1.20E-09 7.02E-09 1.67E-11 3.53E-10 1.54E-10 1.39E-06 4.40E-07 3.62E-07 2.77E-07 4.42E-06 8.33E-09 2.59E-09 1.26E-09 7.50E-11 9.59E-11 1.15E-15 5.50E-13 2537 PPC-S Pipe 15J1319 8.00E-10 4.68E-09 1.11E-11 2.35E-10 1.02E-10 9.28E-07 2.94E-07 2.42E-07 1.85E-07 2.94E-06 5.55E-09 1.73E-09 8.40E-10 5.00E-11 6.39E-11 7.68E-16 3.66E-13 2538 PPC-S Pipe 15J933 2.39E-07 1.40E-06 3.33E-09 7.04E-08 3.06E-08 2.78E-04 8.79E-05 7.23E-05 5.53E-05 8.81E-04 1.66E-06 5.17E-07 2.51E-07 1.50E-08 1.91E-08 2.30E-13 1.10E-10 2539 PPC-S Pipe 15P1355 1.53E-08 8.97E-08 2.13E-10 4.51E-09 1.96E-09 1.78E-05 5.63E-06 4.63E-06 3.54E-06 5.64E-05 1.06E-07 3.31E-08 1.61E-08 9.58E-10 1.22E-09 1.47E-14 7.02E-12 2540 PPC-S Pipe 15P1356 1.53E-08 8.97E-08 2.13E-10 4.51E-09 1.96E-09 1.78E-05 5.63E-06 4.63E-06 3.54E-06 5.64E-05 1.06E-07 3.31E-08 1.61E-08 9.58E-10 1.22E-09 1.47E-14 7.02E-12 2541 PPC-S Pipe 15P1365 8.00E-11 4.68E-10 1.11E-12 2.35E-11 1.02E-11 9.28E-08 2.94E-08 2.42E-08 1.85E-08 2.94E-07 5.55E-10 1.73E-10 8.40E-11 5.00E-12 6.39E-12 7.68E-17 3.66E-14 2542 PPC-S Pipe 15P1388 2.31E-08 1.35E-07 3.21E-10 6.78E-09 2.95E-09 2.68E-05 8.47E-06 6.97E-06 5.33E-06 8.49E-05 1.60E-07 4.98E-08 2.42E-08 1.44E-09 1.84E-09 2.21E-14 1.06E-11 2543 PPC-S Pipe 15S720 7.20E-09 4.21E-08 1.00E-10 2.12E-09 9.21E-10 8.35E-06 2.64E-06 2.17E-06 1.66E-06 2.65E-05 4.99E-08 1.55E-08 7.56E-09 4.50E-10 5.75E-10 6.91E-15 3.30E-12 2544 PPC-S Pipe 15V1089 1.29E-08 7.58E-08 1.80E-10 3.81E-09 1.66E-09 1.50E-05 4.75E-06 3.91E-06 2.99E-06 4.77E-05 8.99E-08 2.80E-08 1.36E-08 8.09E-10 1.03E-09 1.24E-14 5.93E-12 2545 PPC-S Pipe 15V947 1.00E-08 5.85E-08 1.39E-10 2.94E-09 1.28E-09 1.16E-05 3.67E-06 3.02E-06 2.31E-06 3.68E-05 6.94E-08 2.16E-08 1.05E-08 6.25E-10 7.99E-10 9.60E-15 4.58E-12
WVDP-606 Rev. 1 Page 33 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2546 PPC-S Pipe 5CH588 4.00E-07 2.34E-06 5.56E-09 1.18E-07 5.12E-08 4.64E-04 1.47E-04 1.21E-04 9.24E-05 1.47E-03 2.78E-06 8.64E-07 4.20E-07 2.50E-08 3.20E-08 3.84E-13 1.83E-10 2547 PPC-S Pipe 5CH92 2.64E-10 1.55E-09 3.67E-12 7.77E-11 3.38E-11 3.07E-07 9.70E-08 7.98E-08 6.10E-08 9.72E-07 1.83E-09 5.71E-10 2.77E-10 1.65E-11 2.11E-11 2.54E-16 1.21E-13 2548 PPC-S Pipe 5CW189 2.16E-06 1.26E-05 3.00E-08 6.35E-07 2.77E-07 2.51E-03 7.93E-04 6.52E-04 4.99E-04 7.95E-03 1.50E-05 4.67E-06 2.27E-06 1.35E-07 1.73E-07 2.07E-12 9.90E-10 2549 PPC-S Pipe 5CW190 1.01E-06 5.89E-06 1.40E-08 2.96E-07 1.29E-07 1.17E-03 3.70E-04 3.04E-04 2.33E-04 3.71E-03 6.99E-06 2.18E-06 1.06E-06 6.30E-08 8.05E-08 9.67E-13 4.61E-10 2550 PPC-S Pipe 5CW216 1.38E-09 8.10E-09 1.92E-11 4.07E-10 1.77E-10 1.61E-06 5.08E-07 4.18E-07 3.20E-07 5.09E-06 9.60E-09 2.99E-09 1.45E-09 8.65E-11 1.11E-10 1.33E-15 6.34E-13 2551 PPC-S Pipe 5CW216 2.31E-09 1.35E-08 3.21E-11 6.78E-10 2.95E-10 2.68E-06 8.47E-07 6.97E-07 5.33E-07 8.49E-06 1.60E-08 4.98E-09 2.42E-09 1.44E-10 1.84E-10 2.21E-15 1.06E-12 2552 PPC-S Pipe 5CW217 5.53E-09 3.24E-08 7.69E-11 1.63E-09 7.08E-10 6.42E-06 2.03E-06 1.67E-06 1.28E-06 2.04E-05 3.84E-08 1.20E-08 5.81E-09 3.46E-10 4.42E-10 5.31E-15 2.53E-12 2553 PPC-S Pipe 5DW166 4.58E-09 2.68E-08 6.37E-11 1.35E-09 5.87E-10 5.32E-06 1.68E-06 1.38E-06 1.06E-06 1.69E-05 3.18E-08 9.90E-09 4.81E-09 2.86E-10 3.66E-10 4.40E-15 2.10E-12 2554 PPC-S Pipe 5DW167 6.10E-09 3.57E-08 8.48E-11 1.79E-09 7.81E-10 7.08E-06 2.24E-06 1.84E-06 1.41E-06 2.25E-05 4.23E-08 1.32E-08 6.41E-09 3.81E-10 4.88E-10 5.86E-15 2.79E-12 2555 PPC-S Pipe 5DW168 1.53E-09 8.97E-09 2.13E-11 4.51E-10 1.96E-10 1.78E-06 5.63E-07 4.63E-07 3.54E-07 5.64E-06 1.06E-08 3.31E-09 1.61E-09 9.58E-11 1.22E-10 1.47E-15 7.02E-13 2556 PPC-S Pipe 5DW172 3.81E-09 2.23E-08 5.30E-11 1.12E-09 4.88E-10 4.42E-06 1.40E-06 1.15E-06 8.80E-07 1.40E-05 2.64E-08 8.23E-09 4.00E-09 2.38E-10 3.04E-10 3.66E-15 1.75E-12 2557 PPC-S Pipe 5IA152 2.39E-08 1.40E-07 3.33E-10 7.04E-09 3.06E-09 2.78E-05 8.79E-06 7.23E-06 5.53E-06 8.81E-05 1.66E-07 5.17E-08 2.51E-08 1.50E-09 1.91E-09 2.30E-14 1.10E-11 2558 PPC-S Pipe 5IA152 4.00E-08 2.34E-07 5.56E-10 1.18E-08 5.12E-09 4.64E-05 1.47E-05 1.21E-05 9.24E-06 1.47E-04 2.78E-07 8.64E-08 4.20E-08 2.50E-09 3.20E-09 3.84E-14 1.83E-11 2559 PPC-S Pipe 5IA156 4.00E-07 2.34E-06 5.56E-09 1.18E-07 5.12E-08 4.64E-04 1.47E-04 1.21E-04 9.24E-05 1.47E-03 2.78E-06 8.64E-07 4.20E-07 2.50E-08 3.20E-08 3.84E-13 1.83E-10 2560 PPC-S Pipe 5IA220 4.00E-11 2.34E-10 5.56E-13 1.18E-11 5.12E-12 4.64E-08 1.47E-08 1.21E-08 9.24E-09 1.47E-07 2.78E-10 8.64E-11 4.20E-11 2.50E-12 3.20E-12 3.84E-17 1.83E-14 2561 PPC-S Pipe 5IA221 1.20E-07 7.02E-07 1.67E-09 3.53E-08 1.54E-08 1.39E-04 4.40E-05 3.62E-05 2.77E-05 4.42E-04 8.33E-07 2.59E-07 1.26E-07 7.50E-09 9.59E-09 1.15E-13 5.50E-11 2562 PPC-S Pipe 5IA258 2.39E-11 1.40E-10 3.33E-13 7.04E-12 3.06E-12 2.78E-08 8.79E-09 7.23E-09 5.53E-09 8.81E-08 1.66E-10 5.17E-11 2.51E-11 1.50E-12 1.91E-12 2.30E-17 1.10E-14 2563 PPC-S Pipe 5IA258 4.00E-11 2.34E-10 5.56E-13 1.18E-11 5.12E-12 4.64E-08 1.47E-08 1.21E-08 9.24E-09 1.47E-07 2.78E-10 8.64E-11 4.20E-11 2.50E-12 3.20E-12 3.84E-17 1.83E-14 2564 PPC-S Pipe 5IA270 4.00E-09 2.34E-08 5.56E-11 1.18E-09 5.12E-10 4.64E-06 1.47E-06 1.21E-06 9.24E-07 1.47E-05 2.78E-08 8.64E-09 4.20E-09 2.50E-10 3.20E-10 3.84E-15 1.83E-12 2565 PPC-S Pipe 5IA338 4.00E-11 2.34E-10 5.56E-13 1.18E-11 5.12E-12 4.64E-08 1.47E-08 1.21E-08 9.24E-09 1.47E-07 2.78E-10 8.64E-11 4.20E-11 2.50E-12 3.20E-12 3.84E-17 1.83E-14 2566 PPC-S Pipe 5J240A 4.80E-08 2.81E-07 6.68E-10 1.41E-08 6.15E-09 5.57E-05 1.76E-05 1.45E-05 1.11E-05 1.77E-04 3.33E-07 1.04E-07 5.04E-08 3.00E-09 3.84E-09 4.61E-14 2.20E-11 2567 PPC-S Pipe 5J240A 8.00E-08 4.68E-07 1.11E-09 2.35E-08 1.02E-08 9.28E-05 2.94E-05 2.42E-05 1.85E-05 2.94E-04 5.55E-07 1.73E-07 8.40E-08 5.00E-09 6.39E-09 7.68E-14 3.66E-11 2568 PPC-S Pipe 5J240B 4.80E-08 2.81E-07 6.68E-10 1.41E-08 6.15E-09 5.57E-05 1.76E-05 1.45E-05 1.11E-05 1.77E-04 3.33E-07 1.04E-07 5.04E-08 3.00E-09 3.84E-09 4.61E-14 2.20E-11 2569 PPC-S Pipe 5J240B 8.00E-08 4.68E-07 1.11E-09 2.35E-08 1.02E-08 9.28E-05 2.94E-05 2.42E-05 1.85E-05 2.94E-04 5.55E-07 1.73E-07 8.40E-08 5.00E-09 6.39E-09 7.68E-14 3.66E-11 2570 PPC-S Pipe 5J241A 4.00E-09 2.34E-08 5.56E-11 1.18E-09 5.12E-10 4.64E-06 1.47E-06 1.21E-06 9.24E-07 1.47E-05 2.78E-08 8.64E-09 4.20E-09 2.50E-10 3.20E-10 3.84E-15 1.83E-12 2571 PPC-S Pipe 5J241B 4.00E-09 2.34E-08 5.56E-11 1.18E-09 5.12E-10 4.64E-06 1.47E-06 1.21E-06 9.24E-07 1.47E-05 2.78E-08 8.64E-09 4.20E-09 2.50E-10 3.20E-10 3.84E-15 1.83E-12 2572 PPC-S Pipe 5J241C 4.00E-09 2.34E-08 5.56E-11 1.18E-09 5.12E-10 4.64E-06 1.47E-06 1.21E-06 9.24E-07 1.47E-05 2.78E-08 8.64E-09 4.20E-09 2.50E-10 3.20E-10 3.84E-15 1.83E-12 2573 PPC-S Pipe 5P11 1.16E-08 6.77E-08 1.61E-10 3.40E-09 1.48E-09 1.34E-05 4.25E-06 3.50E-06 2.67E-06 4.26E-05 8.03E-08 2.50E-08 1.22E-08 7.24E-10 9.25E-10 1.11E-14 5.30E-12 2574 PPC-S Pipe 5P204 1.80E-07 1.05E-06 2.50E-09 5.28E-08 2.30E-08 2.08E-04 6.59E-05 5.42E-05 4.15E-05 6.61E-04 1.25E-06 3.88E-07 1.89E-07 1.12E-08 1.43E-08 1.72E-13 8.22E-11 2575 PPC-S Pipe 5P222A 5.59E-11 3.27E-10 7.77E-13 1.64E-11 7.16E-12 6.49E-08 2.05E-08 1.69E-08 1.29E-08 2.06E-07 3.88E-10 1.21E-10 5.87E-11 3.49E-12 4.47E-12 5.37E-17 2.56E-14 2576 PPC-S Pipe 5P222B 1.40E-11 8.19E-11 1.95E-13 4.12E-12 1.79E-12 1.62E-08 5.14E-09 4.23E-09 3.23E-09 5.15E-08 9.72E-11 3.02E-11 1.47E-11 8.75E-13 1.12E-12 1.34E-17 6.41E-15 2577 PPC-S Pipe 5P222C 1.40E-11 8.19E-11 1.95E-13 4.12E-12 1.79E-12 1.62E-08 5.14E-09 4.23E-09 3.23E-09 5.15E-08 9.72E-11 3.02E-11 1.47E-11 8.75E-13 1.12E-12 1.34E-17 6.41E-15 2578 PPC-S Pipe 5P249 5.01E-09 2.93E-08 6.96E-11 1.47E-09 6.41E-10 5.81E-06 1.84E-06 1.51E-06 1.16E-06 1.84E-05 3.48E-08 1.08E-08 5.26E-09 3.13E-10 4.00E-10 4.81E-15 2.29E-12 2579 PPC-S Pipe 5P253 8.64E-08 5.06E-07 1.20E-09 2.54E-08 1.11E-08 1.00E-04 3.17E-05 2.61E-05 2.00E-05 3.18E-04 6.00E-07 1.87E-07 9.07E-08 5.40E-09 6.91E-09 8.30E-14 3.96E-11 2580 PPC-S Pipe 5P330 1.68E-05 9.82E-05 2.33E-07 4.94E-06 2.15E-06 1.95E-02 6.16E-03 5.07E-03 3.88E-03 6.18E-02 1.17E-04 3.63E-05 1.76E-05 1.05E-06 1.34E-06 1.61E-11 7.69E-09
WVDP-606 Rev. 1 Page 34 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2581 PPC-S Pipe 5P367 1.50E-05 8.80E-05 2.09E-07 4.42E-06 1.92E-06 1.74E-02 5.52E-03 4.54E-03 3.47E-03 5.53E-02 1.04E-04 3.25E-05 1.58E-05 9.40E-07 1.20E-06 1.44E-11 6.89E-09 2582 PPC-S Pipe 5P367 2.50E-05 1.46E-04 3.47E-07 7.34E-06 3.20E-06 2.90E-02 9.16E-03 7.54E-03 5.77E-03 9.19E-02 1.73E-04 5.39E-05 2.62E-05 1.56E-06 1.99E-06 2.40E-11 1.14E-08 2583 PPC-S Pipe 5P368 4.99E-07 2.92E-06 6.94E-09 1.47E-07 6.39E-08 5.79E-04 1.83E-04 1.51E-04 1.15E-04 1.84E-03 3.46E-06 1.08E-06 5.24E-07 3.12E-08 3.99E-08 4.79E-13 2.29E-10 2584 PPC-S Pipe 5P368 6.00E-08 3.51E-07 8.34E-10 1.76E-08 7.68E-09 6.96E-05 2.20E-05 1.81E-05 1.39E-05 2.21E-04 4.16E-07 1.30E-07 6.30E-08 3.75E-09 4.79E-09 5.76E-14 2.75E-11 2585 PPC-S Pipe 5P370 1.00E-05 5.85E-05 1.39E-07 2.94E-06 1.28E-06 1.16E-02 3.67E-03 3.02E-03 2.31E-03 3.68E-02 6.94E-05 2.16E-05 1.05E-05 6.25E-07 7.99E-07 9.60E-12 4.58E-09 2586 PPC-S Pipe 5P370 1.00E-05 5.85E-05 1.39E-07 2.94E-06 1.28E-06 1.16E-02 3.67E-03 3.02E-03 2.31E-03 3.68E-02 6.94E-05 2.16E-05 1.05E-05 6.25E-07 7.99E-07 9.60E-12 4.58E-09 2587 PPC-S Pipe 5P376 4.00E-07 2.34E-06 5.56E-09 1.18E-07 5.12E-08 4.64E-04 1.47E-04 1.21E-04 9.24E-05 1.47E-03 2.78E-06 8.64E-07 4.20E-07 2.50E-08 3.20E-08 3.84E-13 1.83E-10 2588 PPC-S Pipe 5P379 1.61E-07 9.39E-07 2.23E-09 4.72E-08 2.06E-08 1.86E-04 5.89E-05 4.85E-05 3.71E-05 5.91E-04 1.11E-06 3.47E-07 1.69E-07 1.00E-08 1.28E-08 1.54E-13 7.35E-11 2589 PPC-S Pipe 5P383 2.00E-07 1.17E-06 2.78E-09 5.88E-08 2.56E-08 2.32E-04 7.34E-05 6.04E-05 4.62E-05 7.36E-04 1.39E-06 4.32E-07 2.10E-07 1.25E-08 1.60E-08 1.92E-13 9.16E-11 2590 PPC-S Pipe 5P392 4.00E-09 2.34E-08 5.56E-11 1.18E-09 5.12E-10 4.64E-06 1.47E-06 1.21E-06 9.24E-07 1.47E-05 2.78E-08 8.64E-09 4.20E-09 2.50E-10 3.20E-10 3.84E-15 1.83E-12 2591 PPC-S Pipe 5P402 3.61E-05 2.11E-04 5.01E-07 1.06E-05 4.62E-06 4.18E-02 1.32E-02 1.09E-02 8.33E-03 1.33E-01 2.50E-04 7.79E-05 3.79E-05 2.25E-06 2.88E-06 3.46E-11 1.65E-08 2592 PPC-S Pipe 5P51 1.82E-07 1.07E-06 2.54E-09 5.36E-08 2.34E-08 2.12E-04 6.70E-05 5.51E-05 4.22E-05 6.72E-04 1.27E-06 3.94E-07 1.92E-07 1.14E-08 1.46E-08 1.75E-13 8.36E-11 2593 PPC-S Pipe 5P51 3.05E-07 1.78E-06 4.24E-09 8.97E-08 3.91E-08 3.54E-04 1.12E-04 9.21E-05 7.05E-05 1.12E-03 2.12E-06 6.59E-07 3.20E-07 1.91E-08 2.44E-08 2.93E-13 1.40E-10 2594 PPC-S Pipe 5P52 4.47E-08 2.61E-07 6.21E-10 1.31E-08 5.72E-09 5.18E-05 1.64E-05 1.35E-05 1.03E-05 1.64E-04 3.10E-07 9.65E-08 4.69E-08 2.79E-09 3.57E-09 4.29E-14 2.05E-11 2595 PPC-S Pipe 5P53 1.15E-08 6.75E-08 1.60E-10 3.39E-09 1.48E-09 1.34E-05 4.23E-06 3.48E-06 2.66E-06 4.24E-05 8.00E-08 2.49E-08 1.21E-08 7.21E-10 9.21E-10 1.11E-14 5.28E-12 2596 PPC-S Pipe 5P54 4.10E-08 2.40E-07 5.70E-10 1.21E-08 5.25E-09 4.76E-05 1.51E-05 1.24E-05 9.48E-06 1.51E-04 2.85E-07 8.86E-08 4.31E-08 2.56E-09 3.28E-09 3.94E-14 1.88E-11 2597 PPC-S Pipe 5P62 1.53E-08 8.97E-08 2.13E-10 4.51E-09 1.96E-09 1.78E-05 5.63E-06 4.63E-06 3.54E-06 5.64E-05 1.06E-07 3.31E-08 1.61E-08 9.58E-10 1.22E-09 1.47E-14 7.02E-12 2598 PPC-S Pipe 5P64 7.69E-08 4.50E-07 1.07E-09 2.26E-08 9.85E-09 8.92E-05 2.82E-05 2.32E-05 1.78E-05 2.83E-04 5.34E-07 1.66E-07 8.08E-08 4.81E-09 6.15E-09 7.39E-14 3.52E-11 2599 PPC-S Pipe 5P649 6.16E-08 3.60E-07 8.56E-10 1.81E-08 7.89E-09 7.15E-05 2.26E-05 1.86E-05 1.42E-05 2.27E-04 4.28E-07 1.33E-07 6.47E-08 3.85E-09 4.92E-09 5.91E-14 2.82E-11 2600 PPC-S Pipe 5P71 4.61E-09 2.70E-08 6.41E-11 1.36E-09 5.90E-10 5.35E-06 1.69E-06 1.39E-06 1.07E-06 1.70E-05 3.20E-08 9.96E-09 4.84E-09 2.88E-10 3.69E-10 4.43E-15 2.11E-12 2601 PPC-S Pipe 5P72 2.99E-08 1.75E-07 4.16E-10 8.80E-09 3.83E-09 3.47E-05 1.10E-05 9.04E-06 6.91E-06 1.10E-04 2.08E-07 6.46E-08 3.14E-08 1.87E-09 2.39E-09 2.87E-14 1.37E-11 2602 PPC-S Pipe 5P73 2.98E-08 1.74E-07 4.14E-10 8.76E-09 3.81E-09 3.45E-05 1.09E-05 8.99E-06 6.88E-06 1.10E-04 2.07E-07 6.43E-08 3.13E-08 1.86E-09 2.38E-09 2.86E-14 1.36E-11 2603 PPC-S Pipe 5P74 4.61E-09 2.70E-08 6.41E-11 1.36E-09 5.90E-10 5.35E-06 1.69E-06 1.39E-06 1.07E-06 1.70E-05 3.20E-08 9.96E-09 4.84E-09 2.88E-10 3.69E-10 4.43E-15 2.11E-12 2604 PPC-S Pipe 5P75 3.08E-09 1.80E-08 4.28E-11 9.06E-10 3.94E-10 3.57E-06 1.13E-06 9.30E-07 7.12E-07 1.13E-05 2.14E-08 6.65E-09 3.23E-09 1.93E-10 2.46E-10 2.96E-15 1.41E-12 2605 PPC-S Pipe 5P81 1.08E-08 6.30E-08 1.50E-10 3.17E-09 1.38E-09 1.25E-05 3.95E-06 3.25E-06 2.49E-06 3.96E-05 7.48E-08 2.33E-08 1.13E-08 6.73E-10 8.61E-10 1.03E-14 4.93E-12 2606 PPC-S Pipe 5P90 2.98E-08 1.74E-07 4.14E-10 8.76E-09 3.81E-09 3.45E-05 1.09E-05 8.99E-06 6.88E-06 1.10E-04 2.07E-07 6.43E-08 3.13E-08 1.86E-09 2.38E-09 2.86E-14 1.36E-11 2607 PPC-S Pipe 5P95 2.00E-07 1.17E-06 2.78E-09 5.88E-08 2.56E-08 2.32E-04 7.34E-05 6.04E-05 4.62E-05 7.36E-04 1.39E-06 4.32E-07 2.10E-07 1.25E-08 1.60E-08 1.92E-13 9.16E-11 2608 PPC-S Pipe 5S66 2.77E-10 1.62E-09 3.86E-12 8.15E-11 3.55E-11 3.22E-07 1.02E-07 8.38E-08 6.41E-08 1.02E-06 1.92E-09 5.99E-10 2.91E-10 1.73E-11 2.22E-11 2.66E-16 1.27E-13 2609 PPC-S Pipe 5S96 1.19E-09 6.97E-09 1.66E-11 3.50E-10 1.52E-10 1.38E-06 4.37E-07 3.60E-07 2.75E-07 4.38E-06 8.27E-09 2.57E-09 1.25E-09 7.45E-11 9.52E-11 1.14E-15 5.46E-13 2610 PPC-S Pipe 5UA193 2.16E-07 1.26E-06 3.00E-09 6.35E-08 2.77E-08 2.51E-04 7.93E-05 6.52E-05 4.99E-05 7.95E-04 1.50E-06 4.67E-07 2.27E-07 1.35E-08 1.73E-08 2.07E-13 9.90E-11 2611 PPC-S Pipe 5UA210 2.39E-08 1.40E-07 3.33E-10 7.04E-09 3.06E-09 2.78E-05 8.79E-06 7.23E-06 5.53E-06 8.81E-05 1.66E-07 5.17E-08 2.51E-08 1.50E-09 1.91E-09 2.30E-14 1.10E-11 2612 PPC-S Pipe 5UA210 4.00E-08 2.34E-07 5.56E-10 1.18E-08 5.12E-09 4.64E-05 1.47E-05 1.21E-05 9.24E-06 1.47E-04 2.78E-07 8.64E-08 4.20E-08 2.50E-09 3.20E-09 3.84E-14 1.83E-11 2613 PPC-S Pipe 5UA210 4.00E-08 2.34E-07 5.56E-10 1.18E-08 5.12E-09 4.64E-05 1.47E-05 1.21E-05 9.24E-06 1.47E-04 2.78E-07 8.64E-08 4.20E-08 2.50E-09 3.20E-09 3.84E-14 1.83E-11 2614 PPC-S Pipe 5UA522 2.00E-08 1.17E-07 2.78E-10 5.88E-09 2.56E-09 2.32E-05 7.34E-06 6.04E-06 4.62E-06 7.36E-05 1.39E-07 4.32E-08 2.10E-08 1.25E-09 1.60E-09 1.92E-14 9.16E-12 2615 PPC-S Pipe 6-71-095 4.80E-06 2.81E-05 6.68E-08 1.41E-06 6.15E-07 5.57E-03 1.76E-03 1.45E-03 1.11E-03 1.77E-02 3.33E-05 1.04E-05 5.04E-06 3.00E-07 3.84E-07 4.61E-12 2.20E-09
WVDP-606 Rev. 1 Page 35 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2616 PPC-S Pipe 6-71-110 2.00E-06 1.17E-05 2.78E-08 5.88E-07 2.56E-07 2.32E-03 7.34E-04 6.04E-04 4.62E-04 7.36E-03 1.39E-05 4.32E-06 2.10E-06 1.25E-07 1.60E-07 1.92E-12 9.16E-10 2617 PPC-S Pipe 6-71-135 9.59E-06 5.61E-05 1.33E-07 2.82E-06 1.23E-06 1.11E-02 3.52E-03 2.90E-03 2.22E-03 3.53E-02 6.66E-05 2.07E-05 1.01E-05 5.99E-07 7.66E-07 9.21E-12 4.39E-09 2618 PPC-S Pipe 6-71-136 5.28E-08 3.09E-07 7.35E-10 1.55E-08 6.76E-09 6.13E-05 1.94E-05 1.60E-05 1.22E-05 1.94E-04 3.67E-07 1.14E-07 5.55E-08 3.30E-09 4.22E-09 5.07E-14 2.42E-11 2619 PPC-S Pipe 6-71-138 2.39E-06 1.40E-05 3.33E-08 7.04E-07 3.06E-07 2.78E-03 8.79E-04 7.23E-04 5.53E-04 8.81E-03 1.66E-05 5.17E-06 2.51E-06 1.50E-07 1.91E-07 2.30E-12 1.10E-09 2620 PPC-S Pipe 6-71-203 1.20E-08 7.02E-08 1.67E-10 3.53E-09 1.54E-09 1.39E-05 4.40E-06 3.62E-06 2.77E-06 4.42E-05 8.33E-08 2.59E-08 1.26E-08 7.50E-10 9.59E-10 1.15E-14 5.50E-12 2621 PPC-S Pipe 6-71-308 3.20E-09 1.87E-08 4.44E-11 9.40E-10 4.09E-10 3.71E-06 1.17E-06 9.66E-07 7.39E-07 1.18E-05 2.22E-08 6.91E-09 3.36E-09 2.00E-10 2.55E-10 3.07E-15 1.46E-12 2622 PPC-S Pipe 6-71-313 4.80E-07 2.81E-06 6.68E-09 1.41E-07 6.15E-08 5.57E-04 1.76E-04 1.45E-04 1.11E-04 1.77E-03 3.33E-06 1.04E-06 5.04E-07 3.00E-08 3.84E-08 4.61E-13 2.20E-10 2623 PPC-S Pipe 6-71-314 1.61E-07 9.39E-07 2.23E-09 4.72E-08 2.06E-08 1.86E-04 5.89E-05 4.85E-05 3.71E-05 5.91E-04 1.11E-06 3.47E-07 1.69E-07 1.00E-08 1.28E-08 1.54E-13 7.35E-11 2624 PPC-S Pipe 6-71-390 4.80E-08 2.81E-07 6.68E-10 1.41E-08 6.15E-09 5.57E-05 1.76E-05 1.45E-05 1.11E-05 1.77E-04 3.33E-07 1.04E-07 5.04E-08 3.00E-09 3.84E-09 4.61E-14 2.20E-11 2625 PPC-S Pipe 6-71-438 1.61E-09 9.39E-09 2.23E-11 4.72E-10 2.06E-10 1.86E-06 5.89E-07 4.85E-07 3.71E-07 5.91E-06 1.11E-08 3.47E-09 1.69E-09 1.00E-10 1.28E-10 1.54E-15 7.35E-13 2626 PPC-S Pipe 6-71-444 1.61E-11 9.39E-11 2.23E-13 4.72E-12 2.06E-12 1.86E-08 5.89E-09 4.85E-09 3.71E-09 5.91E-08 1.11E-10 3.47E-11 1.69E-11 1.00E-12 1.28E-12 1.54E-17 7.35E-15 2627 PPC-S Pipe 6-71-448 1.61E-09 9.39E-09 2.23E-11 4.72E-10 2.06E-10 1.86E-06 5.89E-07 4.85E-07 3.71E-07 5.91E-06 1.11E-08 3.47E-09 1.69E-09 1.00E-10 1.28E-10 1.54E-15 7.35E-13 2628 PPC-S Pipe 6-71-452 3.20E-08 1.87E-07 4.44E-10 9.40E-09 4.09E-09 3.71E-05 1.17E-05 9.66E-06 7.39E-06 1.18E-04 2.22E-07 6.91E-08 3.36E-08 2.00E-09 2.55E-09 3.07E-14 1.46E-11 2629 PPC-S Pipe 6-71-631 1.61E-08 9.39E-08 2.23E-10 4.72E-09 2.06E-09 1.86E-05 5.89E-06 4.85E-06 3.71E-06 5.91E-05 1.11E-07 3.47E-08 1.69E-08 1.00E-09 1.28E-09 1.54E-14 7.35E-12 2630 PPC-S Pipe 6-71-632 8.00E-09 4.68E-08 1.11E-10 2.35E-09 1.02E-09 9.28E-06 2.94E-06 2.42E-06 1.85E-06 2.94E-05 5.55E-08 1.73E-08 8.40E-09 5.00E-10 6.39E-10 7.68E-15 3.66E-12 2631 PPC-S Pipe 6-71-633 4.00E-07 2.34E-06 5.56E-09 1.18E-07 5.12E-08 4.64E-04 1.47E-04 1.21E-04 9.24E-05 1.47E-03 2.78E-06 8.64E-07 4.20E-07 2.50E-08 3.20E-08 3.84E-13 1.83E-10 2632 PPC-S Pipe 6-71-699 1.20E-07 7.02E-07 1.67E-09 3.53E-08 1.54E-08 1.39E-04 4.40E-05 3.62E-05 2.77E-05 4.42E-04 8.33E-07 2.59E-07 1.26E-07 7.50E-09 9.59E-09 1.15E-13 5.50E-11 1910 PPH Ceiling 8.56E-08 2.93E-06 2.10E-09 4.35E-08 1.30E-07 3.41E-05 1.20E-05 1.48E-05 1.11E-05 1.06E-04 4.77E-07 1.98E-07 9.67E-08 1.08E-08 1.36E-08 8.21E-14 3.92E-11 1908 PPH East Wall 1.80E-07 6.16E-06 4.40E-09 9.14E-08 2.73E-07 7.17E-05 2.51E-05 3.11E-05 2.33E-05 2.23E-04 1.00E-06 4.15E-07 2.03E-07 2.26E-08 2.86E-08 1.72E-13 8.23E-11 1906 PPH North Wall 3.85E-08 1.32E-06 9.44E-10 1.96E-08 5.86E-08 1.54E-05 5.39E-06 6.67E-06 5.01E-06 4.78E-05 2.15E-07 8.90E-08 4.35E-08 4.85E-09 6.13E-09 3.70E-14 1.76E-11 1907 PPH South Wall 1.07E-09 3.67E-08 2.62E-11 5.45E-10 1.63E-09 4.27E-07 1.50E-07 1.85E-07 1.39E-07 1.33E-06 5.96E-09 2.47E-09 1.21E-09 1.35E-10 1.70E-10 1.03E-15 4.90E-13 1909 PPH West Wall 1.36E-07 4.66E-06 3.33E-09 6.92E-08 2.07E-07 5.43E-05 1.90E-05 2.35E-05 1.77E-05 1.69E-04 7.57E-07 3.14E-07 1.54E-07 1.71E-08 2.16E-08 1.31E-13 6.23E-11 994 PPS WRPA 100' Ceiling 3.37E-06 1.23E-06 1.66E-10 4.17E-09 9.89E-11 1.77E-07 5.38E-08 4.04E-08 3.05E-08 5.32E-07 3.53E-08 2.77E-09 1.29E-09 6.02E-11 8.68E-10 3.23E-12 1.54E-09 1000 PPS WRPA 100' Ceiling 5.11E-06 1.88E-06 2.53E-10 6.34E-09 1.50E-10 2.68E-07 8.18E-08 6.14E-08 4.63E-08 8.08E-07 5.37E-08 4.21E-09 1.96E-09 9.15E-11 1.32E-09 4.91E-12 2.34E-09 1006 PPS WRPA 100' Ceiling 6.65E-07 2.44E-07 3.28E-11 8.25E-10 1.95E-11 3.49E-08 1.06E-08 7.98E-09 6.02E-09 1.05E-07 6.98E-09 5.48E-10 2.55E-10 1.19E-11 1.72E-10 6.38E-13 3.05E-10 992 PPS WRPA 100' E Wall 2.62E-06 9.61E-07 1.29E-10 3.25E-09 7.70E-11 1.37E-07 4.19E-08 3.14E-08 2.37E-08 4.14E-07 2.75E-08 2.16E-09 1.01E-09 4.69E-11 6.76E-10 2.51E-12 1.20E-09 998 PPS WRPA 100' E Wall 4.14E-08 1.52E-08 2.05E-12 5.13E-11 1.22E-12 2.17E-09 6.62E-10 4.97E-10 3.75E-10 6.54E-09 4.35E-10 3.41E-11 1.59E-11 7.41E-13 1.07E-11 3.97E-14 1.90E-11 1004 PPS WRPA 100' E Wall 2.51E-08 9.21E-09 1.24E-12 3.11E-11 7.38E-13 1.32E-09 4.01E-10 3.01E-10 2.27E-10 3.96E-09 2.63E-10 2.07E-11 9.64E-12 4.49E-13 6.47E-12 2.41E-14 1.15E-11 995 PPS WRPA 100' Floor 3.06E-07 1.12E-07 1.51E-11 3.79E-10 8.99E-12 1.61E-08 4.89E-09 3.67E-09 2.77E-09 4.83E-08 3.21E-09 2.52E-10 1.17E-10 5.47E-12 7.89E-11 2.94E-13 1.40E-10 1001 PPS WRPA 100' Floor 1.13E-06 4.16E-07 5.60E-11 1.41E-09 3.33E-11 5.95E-08 1.81E-08 1.36E-08 1.03E-08 1.79E-07 1.19E-08 9.34E-10 4.35E-10 2.03E-11 2.93E-10 1.09E-12 5.19E-10 996 PPS WRPA 100' N Wall 4.16E-06 1.52E-06 2.05E-10 5.15E-09 1.22E-10 2.18E-07 6.65E-08 4.99E-08 3.76E-08 6.57E-07 4.36E-08 3.42E-09 1.60E-09 7.44E-11 1.07E-09 3.99E-12 1.90E-09 1002 PPS WRPA 100' N Wall 4.73E-08 1.74E-08 2.34E-12 5.87E-11 1.39E-12 2.48E-09 7.57E-10 5.68E-10 4.28E-10 7.48E-09 4.97E-10 3.90E-11 1.82E-11 8.47E-13 1.22E-11 4.54E-14 2.17E-11 991 PPS WRPA 100' S Wall 7.97E-07 2.93E-07 3.94E-11 9.89E-10 2.34E-11 4.19E-08 1.28E-08 9.57E-09 7.22E-09 1.26E-07 8.37E-09 6.57E-10 3.06E-10 1.43E-11 2.06E-10 7.65E-13 3.65E-10 997 PPS WRPA 100' S Wall 2.00E-06 7.36E-07 9.90E-11 2.49E-09 5.89E-11 1.05E-07 3.21E-08 2.41E-08 1.81E-08 3.17E-07 2.10E-08 1.65E-09 7.70E-10 3.59E-11 5.17E-10 1.92E-12 9.18E-10 1003 PPS WRPA 100' S Wall 4.73E-08 1.74E-08 2.34E-12 5.87E-11 1.39E-12 2.48E-09 7.57E-10 5.68E-10 4.28E-10 7.48E-09 4.97E-10 3.90E-11 1.82E-11 8.47E-13 1.22E-11 4.54E-14 2.17E-11
WVDP-606 Rev. 1 Page 36 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 993 PPS WRPA 100' W Wall 2.62E-06 9.61E-07 1.29E-10 3.25E-09 7.70E-11 1.37E-07 4.19E-08 3.14E-08 2.37E-08 4.14E-07 2.75E-08 2.16E-09 1.01E-09 4.69E-11 6.76E-10 2.51E-12 1.20E-09 999 PPS WRPA 100' W Wall 6.56E-07 2.41E-07 3.24E-11 8.14E-10 1.93E-11 3.44E-08 1.05E-08 7.87E-09 5.94E-09 1.04E-07 6.89E-09 5.41E-10 2.52E-10 1.17E-11 1.69E-10 6.30E-13 3.01E-10 1005 PPS WRPA 100' W Wall 5.48E-07 2.01E-07 2.71E-11 6.79E-10 1.61E-11 2.88E-08 8.77E-09 6.57E-09 4.96E-09 8.66E-08 5.75E-09 4.51E-10 2.10E-10 9.81E-12 1.41E-10 5.26E-13 2.51E-10 982 PSC-1 114' Ceiling 4.83E-07 1.77E-07 2.39E-11 5.99E-10 1.42E-11 2.53E-08 7.72E-09 5.79E-09 4.37E-09 7.63E-08 5.07E-09 3.98E-10 1.85E-10 8.64E-12 1.25E-10 4.63E-13 2.21E-10 980 PSC-1 114' E Wall 1.76E-07 6.47E-08 8.71E-12 2.19E-10 5.18E-12 9.26E-09 2.82E-09 2.12E-09 1.60E-09 2.79E-08 1.85E-09 1.45E-10 6.77E-11 3.16E-12 4.55E-11 1.69E-13 8.07E-11 983 PSC-1 114' Floor 2.27E-07 8.32E-08 1.12E-11 2.81E-10 6.67E-12 1.19E-08 3.63E-09 2.72E-09 2.05E-09 3.58E-08 2.38E-09 1.87E-10 8.71E-11 4.06E-12 5.85E-11 2.18E-13 1.04E-10 978 PSC-1 114' N Wall 4.22E-07 1.55E-07 2.09E-11 5.23E-10 1.24E-11 2.22E-08 6.75E-09 5.07E-09 3.82E-09 6.67E-08 4.43E-09 3.48E-10 1.62E-10 7.56E-12 1.09E-10 4.05E-13 1.93E-10 979 PSC-1 114' S Wall 3.24E-07 1.19E-07 1.60E-11 4.02E-10 9.53E-12 1.70E-08 5.19E-09 3.89E-09 2.93E-09 5.12E-08 3.40E-09 2.67E-10 1.24E-10 5.80E-12 8.36E-11 3.11E-13 1.48E-10 981 PSC-1 114' W Wall 1.11E-08 4.08E-09 5.49E-13 1.38E-11 3.27E-13 5.84E-10 1.78E-10 1.33E-10 1.01E-10 1.76E-09 1.17E-10 9.16E-12 4.27E-12 1.99E-13 2.87E-12 1.07E-14 5.09E-12 988 PSC-2 114' Ceiling 9.14E-06 3.36E-06 4.52E-10 1.13E-08 2.69E-10 4.80E-07 1.46E-07 1.10E-07 8.28E-08 1.44E-06 9.60E-08 7.53E-09 3.51E-09 1.64E-10 2.36E-09 8.78E-12 4.19E-09 986 PSC-2 114' E Wall 2.66E-06 9.75E-07 1.31E-10 3.29E-09 7.81E-11 1.39E-07 4.25E-08 3.19E-08 2.40E-08 4.20E-07 2.79E-08 2.19E-09 1.02E-09 4.75E-11 6.85E-10 2.55E-12 1.22E-09 989 PSC-2 114' Floor 3.31E-06 1.22E-06 1.64E-10 4.11E-09 9.74E-11 1.74E-07 5.30E-08 3.98E-08 3.00E-08 5.24E-07 3.48E-08 2.73E-09 1.27E-09 5.93E-11 8.55E-10 3.18E-12 1.52E-09 984 PSC-2 114' N Wall 5.23E-06 1.92E-06 2.58E-10 6.49E-09 1.54E-10 2.75E-07 8.37E-08 6.28E-08 4.73E-08 8.26E-07 5.49E-08 4.31E-09 2.01E-09 9.36E-11 1.35E-09 5.02E-12 2.40E-09 985 PSC-2 114' S Wall 3.61E-06 1.33E-06 1.79E-10 4.48E-09 1.06E-10 1.90E-07 5.78E-08 4.34E-08 3.27E-08 5.71E-07 3.79E-08 2.98E-09 1.39E-09 6.47E-11 9.32E-10 3.47E-12 1.66E-09 987 PSC-2 114' W Wall 1.77E-04 6.50E-05 8.75E-09 2.20E-07 5.20E-09 9.29E-06 2.83E-06 2.12E-06 1.60E-06 2.80E-05 1.86E-06 1.46E-07 6.80E-08 3.17E-09 4.57E-08 1.70E-10 8.11E-08 1133 PSC-2 114' Pipe 15IA579 Instrument Air 8.05E-09 2.95E-09 3.98E-13 9.98E-12 2.37E-13 4.22E-10 1.29E-10 9.66E-11 7.28E-11 1.27E-09 8.45E-11 6.63E-12 3.09E-12 1.44E-13 2.08E-12 7.72E-15 3.69E-12 1138 PSC-2 114' Pipe 5P306 Drain & Vent 1.44E-08 5.29E-09 7.12E-13 1.79E-11 4.24E-13 7.57E-10 2.31E-10 1.73E-10 1.30E-10 2.28E-09 1.51E-10 1.19E-11 5.53E-12 2.58E-13 3.72E-12 1.38E-14 6.60E-12 1140 PSC-2 114' Pipe 5P380A Sample 4.81E-07 1.76E-07 2.37E-11 5.96E-10 1.41E-11 2.52E-08 7.69E-09 5.77E-09 4.35E-09 7.59E-08 5.05E-09 3.96E-10 1.85E-10 8.60E-12 1.24E-10 4.61E-13 2.20E-10 1141 PSC-2 114' Pipe 5P380B Sample 1.20E-07 4.40E-08 5.93E-12 1.49E-10 3.53E-12 6.30E-09 1.92E-09 1.44E-09 1.09E-09 1.90E-08 1.26E-09 9.89E-11 4.61E-11 2.15E-12 3.10E-11 1.15E-13 5.49E-11 1134 PSC-2 114' Pipe 5P380C Sample 6.68E-09 2.45E-09 3.30E-13 8.28E-12 1.96E-13 3.51E-10 1.07E-10 8.01E-11 6.04E-11 1.06E-09 7.01E-11 5.50E-12 2.56E-12 1.20E-13 1.72E-12 6.41E-15 3.06E-12 1144 PSC-2 114' Pipe 5P416A Sample 2.41E-06 8.83E-07 1.19E-10 2.98E-09 7.08E-11 1.26E-07 3.85E-08 2.89E-08 2.18E-08 3.80E-07 2.53E-08 1.98E-09 9.24E-10 4.31E-11 6.21E-10 2.31E-12 1.10E-09 1145 PSC-2 114' Pipe 5P416B Sample 1.00E-08 3.68E-09 4.95E-13 1.24E-11 2.95E-13 5.26E-10 1.60E-10 1.20E-10 9.07E-11 1.58E-09 1.05E-10 8.26E-12 3.85E-12 1.79E-13 2.59E-12 9.62E-15 4.59E-12 1136 PSC-2 114' Pipe 5P416C Sample 6.68E-09 2.45E-09 3.30E-13 8.28E-12 1.96E-13 3.51E-10 1.07E-10 8.01E-11 6.04E-11 1.06E-09 7.01E-11 5.50E-12 2.56E-12 1.20E-13 1.72E-12 6.41E-15 3.06E-12 1146 PSC-2 114' Pipe 5P545A Sample 1.81E-05 6.63E-06 8.93E-10 2.24E-08 5.31E-10 9.49E-07 2.89E-07 2.17E-07 1.64E-07 2.85E-06 1.90E-07 1.49E-08 6.94E-09 3.23E-10 4.66E-09 1.73E-11 8.28E-09 1147 PSC-2 114' Pipe 5P545B Sample 1.00E-08 3.68E-09 4.95E-13 1.24E-11 2.95E-13 5.26E-10 1.60E-10 1.20E-10 9.07E-11 1.58E-09 1.05E-10 8.26E-12 3.85E-12 1.79E-13 2.59E-12 9.62E-15 4.59E-12 1137 PSC-2 114' Pipe 5P545C Sample 6.68E-09 2.45E-09 3.30E-13 8.28E-12 1.96E-13 3.51E-10 1.07E-10 8.01E-11 6.04E-11 1.06E-09 7.01E-11 5.50E-12 2.56E-12 1.20E-13 1.72E-12 6.41E-15 3.06E-12 1142 PSC-2 114' Pipe 5P547A Sample 8.05E-07 2.95E-07 3.98E-11 9.98E-10 2.37E-11 4.22E-08 1.29E-08 9.66E-09 7.28E-09 1.27E-07 8.45E-09 6.63E-10 3.09E-10 1.44E-11 2.08E-10 7.72E-13 3.69E-10 1143 PSC-2 114' Pipe 5P547B Sample 1.00E-08 3.68E-09 4.95E-13 1.24E-11 2.95E-13 5.26E-10 1.60E-10 1.20E-10 9.07E-11 1.58E-09 1.05E-10 8.26E-12 3.85E-12 1.79E-13 2.59E-12 9.62E-15 4.59E-12 1135 PSC-2 114' Pipe 5P547C Sample 6.68E-09 2.45E-09 3.30E-13 8.28E-12 1.96E-13 3.51E-10 1.07E-10 8.01E-11 6.04E-11 1.06E-09 7.01E-11 5.50E-12 2.56E-12 1.20E-13 1.72E-12 6.41E-15 3.06E-12 894 PSC-3 131' Ceiling 2.77E-06 1.02E-06 1.37E-10 3.44E-09 8.15E-11 1.46E-07 4.44E-08 3.33E-08 2.51E-08 4.38E-07 2.91E-08 2.28E-09 1.06E-09 4.96E-11 7.15E-10 2.66E-12 1.27E-09 892 PSC-3 131' E Wall 2.82E-06 1.03E-06 1.39E-10 3.49E-09 8.28E-11 1.48E-07 4.51E-08 3.38E-08 2.55E-08 4.45E-07 2.96E-08 2.32E-09 1.08E-09 5.04E-11 7.27E-10 2.70E-12 1.29E-09 895 PSC-3 131' Floor 4.18E-06 1.54E-06 2.07E-10 5.19E-09 1.23E-10 2.20E-07 6.69E-08 5.02E-08 3.79E-08 6.61E-07 4.39E-08 3.45E-09 1.61E-09 7.49E-11 1.08E-09 4.02E-12 1.92E-09 890 PSC-3 131' N Wall 5.71E-07 2.10E-07 2.82E-11 7.08E-10 1.68E-11 3.00E-08 9.14E-09 6.86E-09 5.17E-09 9.03E-08 6.00E-09 4.71E-10 2.19E-10 1.02E-11 1.47E-10 5.48E-13 2.62E-10 891 PSC-3 131' S Wall 4.00E-06 1.47E-06 1.98E-10 4.96E-09 1.18E-10 2.10E-07 6.40E-08 4.80E-08 3.62E-08 6.32E-07 4.20E-08 3.30E-09 1.54E-09 7.16E-11 1.03E-09 3.84E-12 1.83E-09 893 PSC-3 131' W Wall 3.51E-06 1.29E-06 1.73E-10 4.35E-09 1.03E-10 1.84E-07 5.62E-08 4.21E-08 3.18E-08 5.55E-07 3.69E-08 2.89E-09 1.35E-09 6.29E-11 9.06E-10 3.37E-12 1.61E-09
WVDP-606 Rev. 1 Page 37 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1166 Radio/Chem LAB 131' Back 3.48E-08 1.34E-08 4.67E-13 1.03E-11 3.00E-12 8.01E-07 3.23E-07 1.43E-07 1.09E-07 3.17E-06 2.21E-10 2.04E-09 9.86E-10 4.25E-11 6.51E-10 3.34E-14 1.60E-11 1164 Radio/Chem LAB 131' Bottom 1.39E-06 5.35E-07 1.87E-11 4.13E-10 1.20E-10 3.21E-05 1.29E-05 5.72E-06 4.36E-06 1.27E-04 8.84E-09 8.16E-08 3.95E-08 1.70E-09 2.61E-08 1.34E-12 6.39E-10 901 Radio/Chem LAB 131' Ceiling 4.41E-05 1.62E-05 2.18E-09 5.47E-08 1.30E-09 2.32E-06 7.06E-07 5.29E-07 3.99E-07 6.97E-06 4.63E-07 3.63E-08 1.69E-08 7.90E-10 1.14E-08 4.23E-11 2.02E-08 899 Radio/Chem LAB 131' E Wall 3.32E-06 1.22E-06 1.64E-10 4.12E-09 9.76E-11 1.74E-07 5.31E-08 3.99E-08 3.01E-08 5.25E-07 3.49E-08 2.74E-09 1.28E-09 5.94E-11 8.57E-10 3.19E-12 1.52E-09 1162 Radio/Chem LAB 131' Exhaust Duct 1.96E-06 7.52E-07 2.62E-11 5.80E-10 1.69E-10 4.50E-05 1.82E-05 8.03E-06 6.13E-06 1.78E-04 1.24E-08 1.15E-07 5.54E-08 2.39E-09 3.66E-08 1.88E-12 8.97E-10 902 Radio/Chem LAB 131' Floor 1.50E-04 5.50E-05 7.41E-09 1.86E-07 4.41E-09 7.87E-06 2.40E-06 1.80E-06 1.36E-06 2.37E-05 1.57E-06 1.24E-07 5.76E-08 2.68E-09 3.87E-08 1.44E-10 6.87E-08 1165 Radio/Chem LAB 131' Front 3.48E-08 1.34E-08 4.67E-13 1.03E-11 3.00E-12 8.01E-07 3.23E-07 1.43E-07 1.09E-07 3.17E-06 2.21E-10 2.04E-09 9.86E-10 4.25E-11 6.51E-10 3.34E-14 1.60E-11 1169 Radio/Chem LAB 131' Hood #2 4.40E-05 1.61E-05 2.17E-09 5.45E-08 1.29E-09 2.31E-06 7.03E-07 5.28E-07 3.98E-07 6.95E-06 4.62E-07 3.62E-08 1.69E-08 7.87E-10 1.13E-08 4.22E-11 2.01E-08 1170 Radio/Chem LAB 131' Hood #3 1.31E-04 4.81E-05 6.47E-09 1.62E-07 3.85E-09 6.87E-06 2.10E-06 1.57E-06 1.19E-06 2.07E-05 1.37E-06 1.08E-07 5.03E-08 2.34E-09 3.38E-08 1.26E-10 6.00E-08 1171 Radio/Chem LAB 131' Hood #4 8.78E-06 3.22E-06 4.34E-10 1.09E-08 2.58E-10 4.61E-07 1.40E-07 1.05E-07 7.94E-08 1.39E-06 9.22E-08 7.23E-09 3.37E-09 1.57E-10 2.26E-09 8.43E-12 4.02E-09 1172 Radio/Chem LAB 131' Hood #5 8.27E-06 3.03E-06 4.08E-10 1.03E-08 2.43E-10 4.34E-07 1.32E-07 9.92E-08 7.48E-08 1.31E-06 8.68E-08 6.81E-09 3.17E-09 1.48E-10 2.13E-09 7.94E-12 3.79E-09 1173 Radio/Chem LAB 131' Hood #6 3.35E-05 1.23E-05 1.66E-09 4.15E-08 9.85E-10 1.76E-06 5.36E-07 4.02E-07 3.03E-07 5.29E-06 3.52E-07 2.76E-08 1.29E-08 6.00E-10 8.64E-09 3.22E-11 1.53E-08 1174 Radio/Chem LAB 131' Hood #7 3.09E-05 1.14E-05 1.53E-09 3.84E-08 9.10E-10 1.62E-06 4.95E-07 3.71E-07 2.80E-07 4.89E-06 3.25E-07 2.55E-08 1.19E-08 5.54E-10 7.98E-09 2.97E-11 1.42E-08 1175 Radio/Chem LAB 131' Hood #8 9.00E-07 3.30E-07 4.44E-11 1.12E-09 2.65E-11 4.72E-08 1.44E-08 1.08E-08 8.14E-09 1.42E-07 9.45E-09 7.41E-10 3.46E-10 1.61E-11 2.32E-10 8.64E-13 4.12E-10 1167 Radio/Chem LAB 131' Left 2.85E-08 1.10E-08 3.82E-13 8.45E-12 2.46E-12 6.56E-07 2.65E-07 1.17E-07 8.93E-08 2.59E-06 1.81E-10 1.67E-09 8.08E-10 3.48E-11 5.34E-10 2.74E-14 1.31E-11 897 Radio/Chem LAB 131' N Wall 2.65E-05 9.72E-06 1.31E-09 3.28E-08 7.79E-10 1.39E-06 4.24E-07 3.18E-07 2.40E-07 4.18E-06 2.78E-07 2.18E-08 1.02E-08 4.74E-10 6.83E-09 2.54E-11 1.21E-08 1168 Radio/Chem LAB 131' Right 1.90E-08 7.30E-09 2.55E-13 5.62E-12 1.64E-12 4.37E-07 1.76E-07 7.79E-08 5.95E-08 1.73E-06 1.20E-10 1.11E-09 5.38E-10 2.32E-11 3.55E-10 1.82E-14 8.70E-12 898 Radio/Chem LAB 131' S Wall 6.16E-07 2.26E-07 3.04E-11 7.64E-10 1.81E-11 3.23E-08 9.86E-09 7.39E-09 5.57E-09 9.73E-08 6.47E-09 5.08E-10 2.37E-10 1.10E-11 1.59E-10 5.91E-13 2.82E-10 1163 Radio/Chem LAB 131' Top 1.04E-08 4.00E-09 1.39E-13 3.08E-12 8.97E-13 2.39E-07 9.65E-08 4.27E-08 3.26E-08 9.46E-07 6.60E-11 6.09E-10 2.94E-10 1.27E-11 1.95E-10 9.99E-15 4.77E-12 900 Radio/Chem LAB 131' W Wall 2.66E-06 9.75E-07 1.31E-10 3.29E-09 7.81E-11 1.39E-07 4.25E-08 3.19E-08 2.40E-08 4.20E-07 2.79E-08 2.19E-09 1.02E-09 4.75E-11 6.85E-10 2.55E-12 1.22E-09 781 Ram Equipment Room RER Ceiling 3.98E-03 1.46E-03 1.97E-07 4.93E-06 1.17E-07 2.09E-04 6.37E-05 4.78E-05 3.60E-05 6.29E-04 4.18E-05 3.28E-06 1.53E-06 7.12E-08 1.03E-06 3.82E-09 1.82E-06 779 Ram Equipment Room RER E Wall 5.04E-05 1.85E-05 2.49E-09 6.25E-08 1.48E-09 2.65E-06 8.06E-07 6.05E-07 4.56E-07 7.96E-06 5.29E-07 4.15E-08 1.94E-08 9.02E-10 1.30E-08 4.84E-11 2.31E-08 777 Ram Equipment Room RER N Wall 4.46E-06 1.64E-06 2.20E-10 5.53E-09 1.31E-10 2.34E-07 7.14E-08 5.35E-08 4.04E-08 7.05E-07 4.69E-08 3.68E-09 1.71E-09 7.99E-11 1.15E-09 4.28E-12 2.04E-09 778 Ram Equipment Room RER S Wall 2.14E-03 7.87E-04 1.06E-07 2.66E-06 6.30E-08 1.13E-04 3.43E-05 2.57E-05 1.94E-05 3.39E-04 2.25E-05 1.77E-06 8.23E-07 3.84E-08 5.53E-07 2.06E-09 9.82E-07 780 Ram Equipment Room RER W Wall 1.56E-04 5.72E-05 7.70E-09 1.93E-07 4.58E-09 8.18E-06 2.49E-06 1.87E-06 1.41E-06 2.46E-05 1.64E-06 1.28E-07 5.98E-08 2.79E-09 4.02E-08 1.50E-10 7.14E-08 1940 S. Stairs Ceiling 2.93E-06 1.07E-06 1.45E-10 3.63E-09 8.60E-11 1.54E-07 4.68E-08 3.51E-08 2.65E-08 4.62E-07 3.07E-08 2.41E-09 1.12E-09 5.24E-11 7.55E-10 2.81E-12 1.34E-09 1937 S. Stairs East Wall 9.44E-06 3.46E-06 4.66E-10 1.17E-08 2.77E-10 4.95E-07 1.51E-07 1.13E-07 8.54E-08 1.49E-06 9.91E-08 7.78E-09 3.62E-09 1.69E-10 2.43E-09 9.06E-12 4.32E-09 1939 S. Stairs landing 2.27E-05 8.32E-06 1.12E-09 2.81E-08 6.67E-10 1.19E-06 3.63E-07 2.72E-07 2.05E-07 3.58E-06 2.38E-07 1.87E-08 8.71E-09 4.06E-10 5.85E-09 2.18E-11 1.04E-08 1935 S. Stairs N Wall 7.20E-06 2.64E-06 3.56E-10 8.93E-09 2.12E-10 3.78E-07 1.15E-07 8.64E-08 6.51E-08 1.14E-06 7.56E-08 5.93E-09 2.76E-09 1.29E-10 1.86E-09 6.91E-12 3.30E-09 1936 S. Stairs N Wall 4.89E-06 1.80E-06 2.42E-10 6.07E-09 1.44E-10 2.57E-07 7.83E-08 5.87E-08 4.43E-08 7.73E-07 5.14E-08 4.03E-09 1.88E-09 8.76E-11 1.26E-09 4.70E-12 2.24E-09 1938 S. Stairs West Wall 1.32E-05 4.86E-06 6.54E-10 1.64E-08 3.89E-10 6.95E-07 2.12E-07 1.59E-07 1.20E-07 2.09E-06 1.39E-07 1.09E-08 5.08E-09 2.37E-10 3.42E-09 1.27E-11 6.06E-09 1042 SC2 131' Ceiling 4.59E-04 3.75E-04 3.88E-08 9.04E-07 2.48E-10 9.82E-05 3.71E-05 2.91E-05 2.23E-05 4.28E-04 1.24E-07 6.10E-08 3.00E-08 1.18E-09 1.07E-08 4.41E-10 2.10E-07 1040 SC2 131' E Wall 6.49E-04 5.31E-04 5.49E-08 1.28E-06 3.51E-10 1.39E-04 5.25E-05 4.12E-05 3.16E-05 6.06E-04 1.75E-07 8.64E-08 4.25E-08 1.66E-09 1.52E-08 6.23E-10 2.97E-07 1043 SC2 131' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
WVDP-606 Rev. 1 Page 38 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 72 SC2 131' N Wall 3.32E-04 2.71E-04 2.81E-08 6.54E-07 1.79E-10 7.10E-05 2.68E-05 2.11E-05 1.61E-05 3.10E-04 8.96E-08 4.41E-08 2.17E-08 8.50E-10 7.77E-09 3.19E-10 1.52E-07 1039 SC2 131' S Wall 8.75E-04 7.15E-04 7.40E-08 1.72E-06 4.73E-10 1.87E-04 7.07E-05 5.56E-05 4.25E-05 8.16E-04 2.36E-07 1.16E-07 5.72E-08 2.24E-09 2.05E-08 8.40E-10 4.01E-07 1041 SC2 131' W Wall 1.35E-04 1.11E-04 1.15E-08 2.67E-07 7.31E-11 2.90E-05 1.09E-05 8.60E-06 6.58E-06 1.26E-04 3.66E-08 1.80E-08 8.85E-09 3.47E-10 3.17E-09 1.30E-10 6.20E-08 786 Scrap Removal Room SRR Ceiling 8.27E-08 3.03E-08 4.08E-12 1.03E-10 2.43E-12 4.34E-09 1.32E-09 9.92E-10 7.48E-10 1.31E-08 8.68E-10 6.81E-11 3.17E-11 1.48E-12 2.13E-11 7.94E-14 3.79E-11 791 Scrap Removal Room SRR Ceiling 3.41E-07 1.25E-07 1.68E-11 4.23E-10 1.00E-11 1.79E-08 5.45E-09 4.09E-09 3.09E-09 5.39E-08 3.58E-09 2.81E-10 1.31E-10 6.10E-12 8.80E-11 3.27E-13 1.56E-10 796 Scrap Removal Room SRR Ceiling 8.27E-05 3.03E-05 4.08E-09 1.03E-07 2.43E-09 4.34E-06 1.32E-06 9.92E-07 7.48E-07 1.31E-05 8.68E-07 6.81E-08 3.17E-08 1.48E-09 2.13E-08 7.94E-11 3.79E-08 784 Scrap Removal Room SRR E Wall 1.76E-08 6.47E-09 8.71E-13 2.19E-11 5.18E-13 9.26E-10 2.82E-10 2.12E-10 1.60E-10 2.79E-09 1.85E-10 1.45E-11 6.77E-12 3.16E-13 4.55E-12 1.69E-14 8.07E-12 789 Scrap Removal Room SRR E Wall 7.97E-07 2.93E-07 3.94E-11 9.89E-10 2.34E-11 4.19E-08 1.28E-08 9.57E-09 7.22E-09 1.26E-07 8.37E-09 6.57E-10 3.06E-10 1.43E-11 2.06E-10 7.65E-13 3.65E-10 794 Scrap Removal Room SRR E Wall 9.58E-08 3.52E-08 4.73E-12 1.19E-10 2.82E-12 5.03E-09 1.53E-09 1.15E-09 8.67E-10 1.51E-08 1.01E-09 7.90E-11 3.68E-11 1.72E-12 2.47E-11 9.20E-14 4.39E-11 782 Scrap Removal Room SRR N Wall 1.24E-08 4.54E-09 6.11E-13 1.53E-11 3.63E-13 6.49E-10 1.98E-10 1.48E-10 1.12E-10 1.95E-09 1.30E-10 1.02E-11 4.75E-12 2.21E-13 3.19E-12 1.19E-14 5.66E-12 787 Scrap Removal Room SRR N Wall 6.58E-08 2.42E-08 3.25E-12 8.16E-11 1.94E-12 3.46E-09 1.05E-09 7.90E-10 5.96E-10 1.04E-08 6.91E-10 5.43E-11 2.53E-11 1.18E-12 1.70E-11 6.32E-14 3.02E-11 792 Scrap Removal Room SRR N Wall 3.29E-08 1.21E-08 1.63E-12 4.08E-11 9.68E-13 1.73E-09 5.27E-10 3.95E-10 2.98E-10 5.20E-09 3.46E-10 2.71E-11 1.26E-11 5.89E-13 8.49E-12 3.16E-14 1.51E-11 783 Scrap Removal Room SRR S Wall 7.46E-08 2.74E-08 3.69E-12 9.25E-11 2.19E-12 3.92E-09 1.19E-09 8.95E-10 6.75E-10 1.18E-08 7.83E-10 6.15E-11 2.87E-11 1.34E-12 1.93E-11 7.16E-14 3.42E-11 788 Scrap Removal Room SRR S Wall 6.58E-08 2.42E-08 3.25E-12 8.16E-11 1.94E-12 3.46E-09 1.05E-09 7.90E-10 5.96E-10 1.04E-08 6.91E-10 5.43E-11 2.53E-11 1.18E-12 1.70E-11 6.32E-14 3.02E-11 793 Scrap Removal Room SRR S Wall 3.29E-08 1.21E-08 1.63E-12 4.08E-11 9.68E-13 1.73E-09 5.27E-10 3.95E-10 2.98E-10 5.20E-09 3.46E-10 2.71E-11 1.26E-11 5.89E-13 8.49E-12 3.16E-14 1.51E-11 785 Scrap Removal Room SRR W Wall 1.76E-08 6.47E-09 8.71E-13 2.19E-11 5.18E-13 9.26E-10 2.82E-10 2.12E-10 1.60E-10 2.79E-09 1.85E-10 1.45E-11 6.77E-12 3.16E-13 4.55E-12 1.69E-14 8.07E-12 790 Scrap Removal Room SRR W Wall 6.63E-07 2.44E-07 3.28E-11 8.23E-10 1.95E-11 3.48E-08 1.06E-08 7.96E-09 6.00E-09 1.05E-07 6.97E-09 5.47E-10 2.55E-10 1.19E-11 1.71E-10 6.37E-13 3.04E-10 795 Scrap Removal Room SRR W Wall 9.66E-05 3.54E-05 4.77E-09 1.20E-07 2.84E-09 5.07E-06 1.54E-06 1.16E-06 8.74E-07 1.53E-05 1.01E-06 7.96E-08 3.71E-08 1.73E-09 2.49E-08 9.27E-11 4.42E-08 1078 SSC 131' Ceiling 7.00E-03 3.70E-03 6.72E-07 1.42E-05 8.12E-08 5.97E-04 1.58E-04 1.16E-04 8.82E-05 1.49E-03 6.25E-07 4.59E-07 2.26E-07 4.46E-07 1.62E-07 6.72E-09 3.21E-06 1076 SSC 131' E Wall 1.93E-03 1.02E-03 1.85E-07 3.92E-06 2.24E-08 1.64E-04 4.36E-05 3.19E-05 2.43E-05 4.11E-04 1.72E-07 1.27E-07 6.24E-08 1.23E-07 4.46E-08 1.85E-09 8.84E-07 1079 SSC 131' Floor 5.14E-03 2.71E-03 4.93E-07 1.04E-05 5.96E-08 4.38E-04 1.16E-04 8.48E-05 6.47E-05 1.09E-03 4.59E-07 3.37E-07 1.66E-07 3.27E-07 1.19E-07 4.93E-09 2.35E-06 1074 SSC 131' N Wall 6.87E-04 3.63E-04 6.60E-08 1.39E-06 7.97E-09 5.85E-05 1.55E-05 1.13E-05 8.66E-06 1.46E-04 6.14E-08 4.51E-08 2.22E-08 4.38E-08 1.59E-08 6.60E-10 3.15E-07 1075 SSC 131' S Wall 2.34E-03 1.23E-03 2.24E-07 4.74E-06 2.71E-08 1.99E-04 5.28E-05 3.86E-05 2.94E-05 4.98E-04 2.09E-07 1.53E-07 7.55E-08 1.49E-07 5.40E-08 2.24E-09 1.07E-06 1077 SSC 131' W Wall 5.53E-05 2.92E-05 5.31E-09 1.12E-07 6.41E-10 4.71E-06 1.25E-06 9.12E-07 6.97E-07 1.18E-05 4.94E-09 3.63E-09 1.79E-09 3.52E-09 1.28E-09 5.31E-11 2.53E-08 907 SST/PVU Rm 131' Ceiling 2.25E-06 8.27E-07 1.11E-10 2.79E-09 6.62E-11 1.18E-07 3.60E-08 2.70E-08 2.04E-08 3.56E-07 2.37E-08 1.86E-09 8.65E-10 4.03E-11 5.81E-10 2.16E-12 1.03E-09 913 SST/PVU Rm 131' Ceiling 1.13E-06 4.16E-07 5.60E-11 1.41E-09 3.33E-11 5.95E-08 1.81E-08 1.36E-08 1.03E-08 1.79E-07 1.19E-08 9.34E-10 4.35E-10 2.03E-11 2.93E-10 1.09E-12 5.19E-10 905 SST/PVU Rm 131' E Wall 8.56E-07 3.14E-07 4.23E-11 1.06E-09 2.52E-11 4.49E-08 1.37E-08 1.03E-08 7.75E-09 1.35E-07 8.99E-09 7.05E-10 3.29E-10 1.53E-11 2.21E-10 8.22E-13 3.92E-10 911 SST/PVU Rm 131' E Wall 3.50E-08 1.29E-08 1.73E-12 4.34E-11 1.03E-12 1.84E-09 5.61E-10 4.20E-10 3.17E-10 5.54E-09 3.68E-10 2.89E-11 1.35E-11 6.27E-13 9.04E-12 3.36E-14 1.60E-11 908 SST/PVU Rm 131' Floor 1.95E-05 7.17E-06 9.65E-10 2.42E-08 5.74E-10 1.03E-06 3.13E-07 2.34E-07 1.77E-07 3.09E-06 2.05E-07 1.61E-08 7.50E-09 3.50E-10 5.04E-09 1.88E-11 8.95E-09 914 SST/PVU Rm 131' Floor 1.89E-06 6.95E-07 9.36E-11 2.35E-09 5.57E-11 9.95E-08 3.03E-08 2.27E-08 1.71E-08 2.99E-07 1.99E-08 1.56E-09 7.28E-10 3.39E-11 4.89E-10 1.82E-12 8.68E-10 903 SST/PVU Rm 131' N Wall 1.32E-06 4.86E-07 6.54E-11 1.64E-09 3.89E-11 6.95E-08 2.12E-08 1.59E-08 1.20E-08 2.09E-07 1.39E-08 1.09E-09 5.08E-10 2.37E-11 3.42E-10 1.27E-12 6.06E-10 909 SST/PVU Rm 131' N Wall 1.28E-06 4.70E-07 6.32E-11 1.59E-09 3.76E-11 6.72E-08 2.05E-08 1.54E-08 1.16E-08 2.02E-07 1.34E-08 1.05E-09 4.92E-10 2.29E-11 3.30E-10 1.23E-12 5.86E-10 904 SST/PVU Rm 131' S Wall 2.12E-06 7.79E-07 1.05E-10 2.63E-09 6.24E-11 1.11E-07 3.39E-08 2.55E-08 1.92E-08 3.35E-07 2.23E-08 1.75E-09 8.15E-10 3.80E-11 5.47E-10 2.04E-12 9.72E-10
WVDP-606 Rev. 1 Page 39 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 910 SST/PVU Rm 131' S Wall 9.14E-07 3.36E-07 4.52E-11 1.13E-09 2.69E-11 4.80E-08 1.46E-08 1.10E-08 8.28E-09 1.44E-07 9.60E-09 7.53E-10 3.51E-10 1.64E-11 2.36E-10 8.78E-13 4.19E-10 906 SST/PVU Rm 131' W Wall 1.08E-06 3.95E-07 5.31E-11 1.33E-09 3.16E-11 5.65E-08 1.72E-08 1.29E-08 9.73E-09 1.70E-07 1.13E-08 8.86E-10 4.13E-10 1.92E-11 2.77E-10 1.03E-12 4.93E-10 912 SST/PVU Rm 131' W Wall 6.25E-07 2.29E-07 3.09E-11 7.75E-10 1.84E-11 3.28E-08 1.00E-08 7.50E-09 5.65E-09 9.87E-08 6.56E-09 5.15E-10 2.40E-10 1.12E-11 1.61E-10 6.00E-13 2.86E-10 669 Stairs East Ceiling 4.21E-06 1.54E-06 2.08E-10 5.22E-09 1.24E-10 2.21E-07 6.73E-08 5.05E-08 3.81E-08 6.65E-07 4.42E-08 3.47E-09 1.62E-09 7.53E-11 1.09E-09 4.04E-12 1.93E-09 662 Stairs East E Wall 3.18E-05 1.17E-05 1.57E-09 3.95E-08 9.36E-10 1.67E-06 5.09E-07 3.82E-07 2.88E-07 5.03E-06 3.34E-07 2.62E-08 1.22E-08 5.70E-10 8.21E-09 3.05E-11 1.46E-08 670 Stairs East N Wall 1.83E-05 6.71E-06 9.03E-10 2.27E-08 5.38E-10 9.60E-07 2.93E-07 2.19E-07 1.66E-07 2.89E-06 1.92E-07 1.51E-08 7.02E-09 3.27E-10 4.72E-09 1.76E-11 8.38E-09 664 Stairs East S Wall 2.07E-05 7.60E-06 1.02E-09 2.57E-08 6.09E-10 1.09E-06 3.31E-07 2.48E-07 1.87E-07 3.27E-06 2.17E-07 1.71E-08 7.95E-09 3.71E-10 5.34E-09 1.99E-11 9.48E-09 671 Stairs East W Wall 3.72E-05 1.37E-05 1.84E-09 4.62E-08 1.09E-09 1.95E-06 5.96E-07 4.47E-07 3.37E-07 5.88E-06 3.91E-07 3.07E-08 1.43E-08 6.67E-10 9.61E-09 3.57E-11 1.71E-08 1951 STR Ceiling 2.14E-06 7.84E-07 1.06E-10 2.65E-09 6.28E-11 1.12E-07 3.42E-08 2.56E-08 1.93E-08 3.37E-07 2.24E-08 1.76E-09 8.20E-10 3.82E-11 5.51E-10 2.05E-12 9.78E-10 1949 STR E Walls 6.85E-07 2.51E-07 3.38E-11 8.49E-10 2.01E-11 3.59E-08 1.10E-08 8.22E-09 6.20E-09 1.08E-07 7.19E-09 5.64E-10 2.63E-10 1.23E-11 1.77E-10 6.57E-13 3.14E-10 1947 STR N Walls 1.95E-07 7.17E-08 9.65E-12 2.42E-10 5.74E-12 1.03E-08 3.13E-09 2.34E-09 1.77E-09 3.09E-08 2.05E-09 1.61E-10 7.50E-11 3.50E-12 5.04E-11 1.88E-13 8.95E-11 1948 STR S Walls 1.60E-07 5.88E-08 7.91E-12 1.99E-10 4.71E-12 8.41E-09 2.56E-09 1.92E-09 1.45E-09 2.53E-08 1.68E-09 1.32E-10 6.15E-11 2.87E-12 4.13E-11 1.54E-13 7.34E-11 1950 STR W Walls 6.61E-06 2.42E-06 3.26E-10 8.19E-09 1.94E-10 3.47E-07 1.06E-07 7.93E-08 5.98E-08 1.04E-06 6.94E-08 5.44E-09 2.54E-09 1.18E-10 1.70E-09 6.34E-12 3.03E-09 1623 ULO 100' 5V-1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1628 ULO 100' Ceiling 1.70E-05 3.98E-07 0.00E+00 0.00E+00 3.03E-10 7.89E-05 1.38E-05 3.49E-05 2.64E-05 1.65E-04 0.00E+00 4.32E-05 2.06E-05 2.31E-06 3.66E-05 1.63E-11 7.79E-09 1771 ULO 100' Ceiling Niche 1.52E-05 3.57E-07 0.00E+00 0.00E+00 2.71E-10 7.07E-05 1.23E-05 3.12E-05 2.36E-05 1.48E-04 0.00E+00 3.87E-05 1.84E-05 2.07E-06 3.28E-05 1.46E-11 6.98E-09 1626 ULO 100' E Wall 9.87E-06 2.31E-07 0.00E+00 0.00E+00 1.76E-10 4.58E-05 7.98E-06 2.02E-05 1.53E-05 9.56E-05 0.00E+00 2.51E-05 1.19E-05 1.34E-06 2.12E-05 9.47E-12 4.52E-09 1769 ULO 100' East Niche Wall 2.28E-05 5.33E-07 0.00E+00 0.00E+00 4.05E-10 1.06E-04 1.84E-05 4.67E-05 3.53E-05 2.21E-04 0.00E+00 5.78E-05 2.75E-05 3.10E-06 4.89E-05 2.19E-11 1.04E-08 1624 ULO 100' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1767 ULO 100' North Niche Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1625 ULO 100' S Wall 1.55E-05 3.64E-07 0.00E+00 0.00E+00 2.77E-10 7.21E-05 1.26E-05 3.18E-05 2.41E-05 1.51E-04 0.00E+00 3.95E-05 1.88E-05 2.11E-06 3.34E-05 1.49E-11 7.12E-09 1768 ULO 100' South Niche Wall 3.23E-05 7.57E-07 0.00E+00 0.00E+00 5.76E-10 1.50E-04 2.62E-05 6.63E-05 5.01E-05 3.13E-04 0.00E+00 8.22E-05 3.91E-05 4.40E-06 6.95E-05 3.10E-11 1.48E-08 1627 ULO 100' W Wall 1.38E-05 3.22E-07 0.00E+00 0.00E+00 2.45E-10 6.39E-05 1.11E-05 2.82E-05 2.14E-05 1.34E-04 0.00E+00 3.50E-05 1.67E-05 1.87E-06 2.96E-05 1.32E-11 6.31E-09 1770 ULO 100' West Niche Wall 3.02E-05 7.07E-07 0.00E+00 0.00E+00 5.37E-10 1.40E-04 2.44E-05 6.19E-05 4.68E-05 2.93E-04 0.00E+00 7.67E-05 3.65E-05 4.11E-06 6.49E-05 2.90E-11 1.38E-08 1702 ULO 100' Pipe 5P375 9.63E-06 2.25E-07 0.00E+00 0.00E+00 1.71E-10 4.47E-05 7.79E-06 1.98E-05 1.49E-05 9.34E-05 0.00E+00 2.45E-05 1.17E-05 1.31E-06 2.07E-05 9.25E-12 4.41E-09 2466 ULO 100' Pipe 5P375 9.63E-06 2.25E-07 0.00E+00 0.00E+00 1.71E-10 4.47E-05 7.79E-06 1.98E-05 1.49E-05 9.34E-05 0.00E+00 2.45E-05 1.17E-05 1.31E-06 2.07E-05 9.25E-12 4.41E-09 1703 ULO 100' Pipe 5P377 7.68E-05 1.80E-06 0.00E+00 0.00E+00 1.37E-09 3.56E-04 6.21E-05 1.57E-04 1.19E-04 7.44E-04 0.00E+00 1.95E-04 9.29E-05 1.04E-05 1.65E-04 7.37E-11 3.52E-08 2467 ULO 100' Pipe 5P377 7.68E-05 1.80E-06 0.00E+00 0.00E+00 1.37E-09 3.56E-04 6.21E-05 1.57E-04 1.19E-04 7.44E-04 0.00E+00 1.95E-04 9.29E-05 1.04E-05 1.65E-04 7.37E-11 3.52E-08 1704 ULO 100' Pipe 5P380A 3.74E-07 8.76E-09 0.00E+00 0.00E+00 6.66E-12 1.74E-06 3.03E-07 7.67E-07 5.80E-07 3.63E-06 0.00E+00 9.51E-07 4.53E-07 5.09E-08 8.05E-07 3.59E-13 1.71E-10 2468 ULO 100' Pipe 5P380A 3.74E-07 8.76E-09 0.00E+00 0.00E+00 6.66E-12 1.74E-06 3.03E-07 7.67E-07 5.80E-07 3.63E-06 0.00E+00 9.51E-07 4.53E-07 5.09E-08 8.05E-07 3.59E-13 1.71E-10 1705 ULO 100' Pipe 5P380B 1.88E-07 4.39E-09 0.00E+00 0.00E+00 3.34E-12 8.71E-07 1.52E-07 3.85E-07 2.91E-07 1.82E-06 0.00E+00 4.77E-07 2.27E-07 2.55E-08 4.03E-07 1.80E-13 8.59E-11 2469 ULO 100' Pipe 5P380B 1.88E-07 4.39E-09 0.00E+00 0.00E+00 3.34E-12 8.71E-07 1.52E-07 3.85E-07 2.91E-07 1.82E-06 0.00E+00 4.77E-07 2.27E-07 2.55E-08 4.03E-07 1.80E-13 8.59E-11 1706 ULO 100' Pipe 5P380C 1.88E-07 4.39E-09 0.00E+00 0.00E+00 3.34E-12 8.71E-07 1.52E-07 3.85E-07 2.91E-07 1.82E-06 0.00E+00 4.77E-07 2.27E-07 2.55E-08 4.03E-07 1.80E-13 8.59E-11 2470 ULO 100' Pipe 5P380C 1.88E-07 4.39E-09 0.00E+00 0.00E+00 3.34E-12 8.71E-07 1.52E-07 3.85E-07 2.91E-07 1.82E-06 0.00E+00 4.77E-07 2.27E-07 2.55E-08 4.03E-07 1.80E-13 8.59E-11 1707 ULO 100' Pipe 5P382 1.60E-04 3.75E-06 0.00E+00 0.00E+00 2.85E-09 7.44E-04 1.30E-04 3.29E-04 2.48E-04 1.55E-03 0.00E+00 4.07E-04 1.94E-04 2.18E-05 3.45E-04 1.54E-10 7.34E-08
WVDP-606 Rev. 1 Page 40 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2471 ULO 100' Pipe 5P382 1.60E-04 3.75E-06 0.00E+00 0.00E+00 2.85E-09 7.44E-04 1.30E-04 3.29E-04 2.48E-04 1.55E-03 0.00E+00 4.07E-04 1.94E-04 2.18E-05 3.45E-04 1.54E-10 7.34E-08 1708 ULO 100' Pipe 5P398 2.57E-05 6.01E-07 0.00E+00 0.00E+00 4.57E-10 1.19E-04 2.08E-05 5.27E-05 3.98E-05 2.49E-04 0.00E+00 6.53E-05 3.11E-05 3.50E-06 5.53E-05 2.47E-11 1.18E-08 2472 ULO 100' Pipe 5P398 2.57E-05 6.01E-07 0.00E+00 0.00E+00 4.57E-10 1.19E-04 2.08E-05 5.27E-05 3.98E-05 2.49E-04 0.00E+00 6.53E-05 3.11E-05 3.50E-06 5.53E-05 2.47E-11 1.18E-08 1709 ULO 100' Pipe 5P399 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 2473 ULO 100' Pipe 5P399 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 1710 ULO 100' Pipe 5P400 1.28E-05 3.00E-07 0.00E+00 0.00E+00 2.28E-10 5.94E-05 1.04E-05 2.62E-05 1.98E-05 1.24E-04 0.00E+00 3.25E-05 1.55E-05 1.74E-06 2.75E-05 1.23E-11 5.86E-09 2474 ULO 100' Pipe 5P400 1.28E-05 3.00E-07 0.00E+00 0.00E+00 2.28E-10 5.94E-05 1.04E-05 2.62E-05 1.98E-05 1.24E-04 0.00E+00 3.25E-05 1.55E-05 1.74E-06 2.75E-05 1.23E-11 5.86E-09 1711 ULO 100' Pipe 6-71-130 2.68E-07 6.26E-09 0.00E+00 0.00E+00 4.77E-12 1.24E-06 2.17E-07 5.49E-07 4.15E-07 2.59E-06 0.00E+00 6.80E-07 3.24E-07 3.64E-08 5.76E-07 2.57E-13 1.23E-10 2475 ULO 100' Pipe 6-71-130 2.68E-07 6.26E-09 0.00E+00 0.00E+00 4.77E-12 1.24E-06 2.17E-07 5.49E-07 4.15E-07 2.59E-06 0.00E+00 6.80E-07 3.24E-07 3.64E-08 5.76E-07 2.57E-13 1.23E-10 1712 ULO 100' Pipe 6-71-136 1.42E-07 3.32E-09 0.00E+00 0.00E+00 2.52E-12 6.57E-07 1.15E-07 2.90E-07 2.20E-07 1.37E-06 0.00E+00 3.60E-07 1.71E-07 1.93E-08 3.05E-07 1.36E-13 6.49E-11 2476 ULO 100' Pipe 6-71-136 1.42E-07 3.32E-09 0.00E+00 0.00E+00 2.52E-12 6.57E-07 1.15E-07 2.90E-07 2.20E-07 1.37E-06 0.00E+00 3.60E-07 1.71E-07 1.93E-08 3.05E-07 1.36E-13 6.49E-11 1713 ULO 100' Pipe 6-71-203 3.21E-08 7.52E-10 0.00E+00 0.00E+00 5.72E-13 1.49E-07 2.60E-08 6.59E-08 4.98E-08 3.12E-07 0.00E+00 8.17E-08 3.89E-08 4.37E-09 6.91E-08 3.09E-14 1.47E-11 2477 ULO 100' Pipe 6-71-203 3.21E-08 7.52E-10 0.00E+00 0.00E+00 5.72E-13 1.49E-07 2.60E-08 6.59E-08 4.98E-08 3.12E-07 0.00E+00 8.17E-08 3.89E-08 4.37E-09 6.91E-08 3.09E-14 1.47E-11 1714 ULO 100' Pipe 6-71-300 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 2478 ULO 100' Pipe 6-71-300 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 1715 ULO 100' Pipe 6-71-301 2.41E-05 5.65E-07 0.00E+00 0.00E+00 4.30E-10 1.12E-04 1.95E-05 4.95E-05 3.74E-05 2.34E-04 0.00E+00 6.13E-05 2.92E-05 3.28E-06 5.19E-05 2.32E-11 1.11E-08 2479 ULO 100' Pipe 6-71-301 2.41E-05 5.65E-07 0.00E+00 0.00E+00 4.30E-10 1.12E-04 1.95E-05 4.95E-05 3.74E-05 2.34E-04 0.00E+00 6.13E-05 2.92E-05 3.28E-06 5.19E-05 2.32E-11 1.11E-08 1716 ULO 100' Pipe 6-71-302 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10 2480 ULO 100' Pipe 6-71-302 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10 1717 ULO 100' Pipe 6-71-303 5.35E-06 1.25E-07 0.00E+00 0.00E+00 9.53E-11 2.48E-05 4.33E-06 1.10E-05 8.30E-06 5.19E-05 0.00E+00 1.36E-05 6.48E-06 7.28E-07 1.15E-05 5.14E-12 2.45E-09 2481 ULO 100' Pipe 6-71-303 5.35E-06 1.25E-07 0.00E+00 0.00E+00 9.53E-11 2.48E-05 4.33E-06 1.10E-05 8.30E-06 5.19E-05 0.00E+00 1.36E-05 6.48E-06 7.28E-07 1.15E-05 5.14E-12 2.45E-09 1718 ULO 100' Pipe 6-71-304 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 2482 ULO 100' Pipe 6-71-304 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 1719 ULO 100' Pipe 6-71-305 4.49E-07 1.05E-08 0.00E+00 0.00E+00 8.00E-12 2.09E-06 3.64E-07 9.21E-07 6.97E-07 4.36E-06 0.00E+00 1.14E-06 5.44E-07 6.11E-08 9.66E-07 4.32E-13 2.06E-10 2483 ULO 100' Pipe 6-71-305 4.49E-07 1.05E-08 0.00E+00 0.00E+00 8.00E-12 2.09E-06 3.64E-07 9.21E-07 6.97E-07 4.36E-06 0.00E+00 1.14E-06 5.44E-07 6.11E-08 9.66E-07 4.32E-13 2.06E-10 1720 ULO 100' Pipe 6-71-306 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 2484 ULO 100' Pipe 6-71-306 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 1721 ULO 100' Pipe 6-71-308 2.14E-08 5.01E-10 0.00E+00 0.00E+00 3.81E-13 9.93E-08 1.73E-08 4.39E-08 3.32E-08 2.07E-07 0.00E+00 5.44E-08 2.59E-08 2.91E-09 4.60E-08 2.05E-14 9.80E-12 2485 ULO 100' Pipe 6-71-308 2.14E-08 5.01E-10 0.00E+00 0.00E+00 3.81E-13 9.93E-08 1.73E-08 4.39E-08 3.32E-08 2.07E-07 0.00E+00 5.44E-08 2.59E-08 2.91E-09 4.60E-08 2.05E-14 9.80E-12 1722 ULO 100' Pipe 6-71-309 1.50E-05 3.50E-07 0.00E+00 0.00E+00 2.66E-10 6.94E-05 1.21E-05 3.06E-05 2.32E-05 1.45E-04 0.00E+00 3.80E-05 1.81E-05 2.03E-06 3.21E-05 1.44E-11 6.85E-09 2486 ULO 100' Pipe 6-71-309 1.50E-05 3.50E-07 0.00E+00 0.00E+00 2.66E-10 6.94E-05 1.21E-05 3.06E-05 2.32E-05 1.45E-04 0.00E+00 3.80E-05 1.81E-05 2.03E-06 3.21E-05 1.44E-11 6.85E-09 1723 ULO 100' Pipe 6-71-310 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 2487 ULO 100' Pipe 6-71-310 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 1724 ULO 100' Pipe 6-71-311 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09 2488 ULO 100' Pipe 6-71-311 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09
WVDP-606 Rev. 1 Page 41 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1725 ULO 100' Pipe 6-71-312 6.42E-05 1.50E-06 0.00E+00 0.00E+00 1.14E-09 2.98E-04 5.19E-05 1.32E-04 9.95E-05 6.22E-04 0.00E+00 1.63E-04 7.77E-05 8.73E-06 1.38E-04 6.16E-11 2.94E-08 2489 ULO 100' Pipe 6-71-312 6.42E-05 1.50E-06 0.00E+00 0.00E+00 1.14E-09 2.98E-04 5.19E-05 1.32E-04 9.95E-05 6.22E-04 0.00E+00 1.63E-04 7.77E-05 8.73E-06 1.38E-04 6.16E-11 2.94E-08 1726 ULO 100' Pipe 6-71-313 3.21E-06 7.52E-08 0.00E+00 0.00E+00 5.72E-11 1.49E-05 2.60E-06 6.59E-06 4.98E-06 3.12E-05 0.00E+00 8.17E-06 3.89E-06 4.37E-07 6.91E-06 3.09E-12 1.47E-09 2490 ULO 100' Pipe 6-71-313 3.21E-06 7.52E-08 0.00E+00 0.00E+00 5.72E-11 1.49E-05 2.60E-06 6.59E-06 4.98E-06 3.12E-05 0.00E+00 8.17E-06 3.89E-06 4.37E-07 6.91E-06 3.09E-12 1.47E-09 1727 ULO 100' Pipe 6-71-314 6.42E-07 1.50E-08 0.00E+00 0.00E+00 1.14E-11 2.98E-06 5.19E-07 1.32E-06 9.95E-07 6.22E-06 0.00E+00 1.63E-06 7.77E-07 8.73E-08 1.38E-06 6.16E-13 2.94E-10 2491 ULO 100' Pipe 6-71-314 6.42E-07 1.50E-08 0.00E+00 0.00E+00 1.14E-11 2.98E-06 5.19E-07 1.32E-06 9.95E-07 6.22E-06 0.00E+00 1.63E-06 7.77E-07 8.73E-08 1.38E-06 6.16E-13 2.94E-10 1728 ULO 100' Pipe 6-71-319 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 2492 ULO 100' Pipe 6-71-319 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 1729 ULO 100' Pipe 6-71-324 4.82E-05 1.13E-06 0.00E+00 0.00E+00 8.57E-10 2.24E-04 3.90E-05 9.88E-05 7.47E-05 4.67E-04 0.00E+00 1.22E-04 5.83E-05 6.55E-06 1.04E-04 4.62E-11 2.21E-08 2493 ULO 100' Pipe 6-71-324 4.82E-05 1.13E-06 0.00E+00 0.00E+00 8.57E-10 2.24E-04 3.90E-05 9.88E-05 7.47E-05 4.67E-04 0.00E+00 1.22E-04 5.83E-05 6.55E-06 1.04E-04 4.62E-11 2.21E-08 1730 ULO 100' Pipe 6-71-325 2.14E-05 5.01E-07 0.00E+00 0.00E+00 3.81E-10 9.93E-05 1.73E-05 4.39E-05 3.32E-05 2.07E-04 0.00E+00 5.44E-05 2.59E-05 2.91E-06 4.60E-05 2.05E-11 9.80E-09 2494 ULO 100' Pipe 6-71-325 2.14E-05 5.01E-07 0.00E+00 0.00E+00 3.81E-10 9.93E-05 1.73E-05 4.39E-05 3.32E-05 2.07E-04 0.00E+00 5.44E-05 2.59E-05 2.91E-06 4.60E-05 2.05E-11 9.80E-09 1731 ULO 100' Pipe 6-71-326 2.14E-05 5.01E-07 0.00E+00 0.00E+00 3.81E-10 9.93E-05 1.73E-05 4.39E-05 3.32E-05 2.07E-04 0.00E+00 5.44E-05 2.59E-05 2.91E-06 4.60E-05 2.05E-11 9.80E-09 2495 ULO 100' Pipe 6-71-326 2.14E-05 5.01E-07 0.00E+00 0.00E+00 3.81E-10 9.93E-05 1.73E-05 4.39E-05 3.32E-05 2.07E-04 0.00E+00 5.44E-05 2.59E-05 2.91E-06 4.60E-05 2.05E-11 9.80E-09 1732 ULO 100' Pipe 6-71-327 2.14E-07 5.01E-09 0.00E+00 0.00E+00 3.81E-12 9.93E-07 1.73E-07 4.39E-07 3.32E-07 2.07E-06 0.00E+00 5.44E-07 2.59E-07 2.91E-08 4.60E-07 2.05E-13 9.80E-11 2496 ULO 100' Pipe 6-71-327 2.14E-07 5.01E-09 0.00E+00 0.00E+00 3.81E-12 9.93E-07 1.73E-07 4.39E-07 3.32E-07 2.07E-06 0.00E+00 5.44E-07 2.59E-07 2.91E-08 4.60E-07 2.05E-13 9.80E-11 1733 ULO 100' Pipe 6-71-328 4.28E-06 1.00E-07 0.00E+00 0.00E+00 7.62E-11 1.99E-05 3.46E-06 8.77E-06 6.63E-06 4.15E-05 0.00E+00 1.09E-05 5.18E-06 5.82E-07 9.20E-06 4.11E-12 1.96E-09 2497 ULO 100' Pipe 6-71-328 4.28E-06 1.00E-07 0.00E+00 0.00E+00 7.62E-11 1.99E-05 3.46E-06 8.77E-06 6.63E-06 4.15E-05 0.00E+00 1.09E-05 5.18E-06 5.82E-07 9.20E-06 4.11E-12 1.96E-09 1734 ULO 100' Pipe 6-71-329 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09 2498 ULO 100' Pipe 6-71-329 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09 1735 ULO 100' Pipe 6-71-390 1.28E-07 3.00E-09 0.00E+00 0.00E+00 2.28E-12 5.94E-07 1.04E-07 2.62E-07 1.98E-07 1.24E-06 0.00E+00 3.25E-07 1.55E-07 1.74E-08 2.75E-07 1.23E-13 5.86E-11 2499 ULO 100' Pipe 6-71-390 1.28E-07 3.00E-09 0.00E+00 0.00E+00 2.28E-12 5.94E-07 1.04E-07 2.62E-07 1.98E-07 1.24E-06 0.00E+00 3.25E-07 1.55E-07 1.74E-08 2.75E-07 1.23E-13 5.86E-11 1736 ULO 100' Pipe 6-71-391 1.01E-06 2.36E-08 0.00E+00 0.00E+00 1.79E-11 4.67E-06 8.14E-07 2.06E-06 1.56E-06 9.75E-06 0.00E+00 2.56E-06 1.22E-06 1.37E-07 2.16E-06 9.66E-13 4.61E-10 2500 ULO 100' Pipe 6-71-391 1.01E-06 2.36E-08 0.00E+00 0.00E+00 1.79E-11 4.67E-06 8.14E-07 2.06E-06 1.56E-06 9.75E-06 0.00E+00 2.56E-06 1.22E-06 1.37E-07 2.16E-06 9.66E-13 4.61E-10 1737 ULO 100' Pipe 6-71-392 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10 2501 ULO 100' Pipe 6-71-392 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10 1738 ULO 100' Pipe 6-71-629 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 2502 ULO 100' Pipe 6-71-629 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 1739 ULO 100' Pipe 6-71-631 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 2503 ULO 100' Pipe 6-71-631 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 1740 ULO 100' Pipe 6-71-632 2.14E-07 5.01E-09 0.00E+00 0.00E+00 3.81E-12 9.93E-07 1.73E-07 4.39E-07 3.32E-07 2.07E-06 0.00E+00 5.44E-07 2.59E-07 2.91E-08 4.60E-07 2.05E-13 9.80E-11 2504 ULO 100' Pipe 6-71-632 2.14E-07 5.01E-09 0.00E+00 0.00E+00 3.81E-12 9.93E-07 1.73E-07 4.39E-07 3.32E-07 2.07E-06 0.00E+00 5.44E-07 2.59E-07 2.91E-08 4.60E-07 2.05E-13 9.80E-11 1741 ULO 100' Pipe 6-71-633 1.07E-06 2.52E-08 0.00E+00 0.00E+00 1.91E-11 4.99E-06 8.70E-07 2.20E-06 1.67E-06 1.04E-05 0.00E+00 2.73E-06 1.30E-06 1.46E-07 2.31E-06 1.03E-12 4.92E-10 2505 ULO 100' Pipe 6-71-633 1.07E-06 2.52E-08 0.00E+00 0.00E+00 1.91E-11 4.99E-06 8.70E-07 2.20E-06 1.67E-06 1.04E-05 0.00E+00 2.73E-06 1.30E-06 1.46E-07 2.31E-06 1.03E-12 4.92E-10 1742 ULO 100' Pipe 6-71-634 1.50E-06 3.50E-08 0.00E+00 0.00E+00 2.66E-11 6.94E-06 1.21E-06 3.06E-06 2.32E-06 1.45E-05 0.00E+00 3.80E-06 1.81E-06 2.03E-07 3.21E-06 1.44E-12 6.85E-10
WVDP-606 Rev. 1 Page 42 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2506 ULO 100' Pipe 6-71-634 1.50E-06 3.50E-08 0.00E+00 0.00E+00 2.66E-11 6.94E-06 1.21E-06 3.06E-06 2.32E-06 1.45E-05 0.00E+00 3.80E-06 1.81E-06 2.03E-07 3.21E-06 1.44E-12 6.85E-10 1743 ULO 100' Pipe 6-71-635 2.68E-05 6.26E-07 0.00E+00 0.00E+00 4.77E-10 1.24E-04 2.17E-05 5.49E-05 4.15E-05 2.59E-04 0.00E+00 6.80E-05 3.24E-05 3.64E-06 5.76E-05 2.57E-11 1.23E-08 2507 ULO 100' Pipe 6-71-635 2.68E-05 6.26E-07 0.00E+00 0.00E+00 4.77E-10 1.24E-04 2.17E-05 5.49E-05 4.15E-05 2.59E-04 0.00E+00 6.80E-05 3.24E-05 3.64E-06 5.76E-05 2.57E-11 1.23E-08 1744 ULO 100' Pipe 6-71-636 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 2508 ULO 100' Pipe 6-71-636 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 1745 ULO 100' Pipe 6-71-661 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09 2509 ULO 100' Pipe 6-71-661 1.07E-05 2.52E-07 0.00E+00 0.00E+00 1.91E-10 4.99E-05 8.70E-06 2.20E-05 1.67E-05 1.04E-04 0.00E+00 2.73E-05 1.30E-05 1.46E-06 2.31E-05 1.03E-11 4.92E-09 1746 ULO 100' Pipe 6-71-662 1.07E-06 2.52E-08 0.00E+00 0.00E+00 1.91E-11 4.99E-06 8.70E-07 2.20E-06 1.67E-06 1.04E-05 0.00E+00 2.73E-06 1.30E-06 1.46E-07 2.31E-06 1.03E-12 4.92E-10 2510 ULO 100' Pipe 6-71-662 1.07E-06 2.52E-08 0.00E+00 0.00E+00 1.91E-11 4.99E-06 8.70E-07 2.20E-06 1.67E-06 1.04E-05 0.00E+00 2.73E-06 1.30E-06 1.46E-07 2.31E-06 1.03E-12 4.92E-10 1747 ULO 100' Pipe 6-71-663 1.39E-06 3.25E-08 0.00E+00 0.00E+00 2.47E-11 6.44E-06 1.12E-06 2.84E-06 2.15E-06 1.34E-05 0.00E+00 3.52E-06 1.68E-06 1.89E-07 2.98E-06 1.33E-12 6.35E-10 2511 ULO 100' Pipe 6-71-663 1.39E-06 3.25E-08 0.00E+00 0.00E+00 2.47E-11 6.44E-06 1.12E-06 2.84E-06 2.15E-06 1.34E-05 0.00E+00 3.52E-06 1.68E-06 1.89E-07 2.98E-06 1.33E-12 6.35E-10 1748 ULO 100' Pipe 6-71-664 2.68E-06 6.26E-08 0.00E+00 0.00E+00 4.77E-11 1.24E-05 2.17E-06 5.49E-06 4.15E-06 2.59E-05 0.00E+00 6.80E-06 3.24E-06 3.64E-07 5.76E-06 2.57E-12 1.23E-09 2512 ULO 100' Pipe 6-71-664 2.68E-06 6.26E-08 0.00E+00 0.00E+00 4.77E-11 1.24E-05 2.17E-06 5.49E-06 4.15E-06 2.59E-05 0.00E+00 6.80E-06 3.24E-06 3.64E-07 5.76E-06 2.57E-12 1.23E-09 1749 ULO 100' Pipe 6-71-665 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 2513 ULO 100' Pipe 6-71-665 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 1750 ULO 100' Pipe 6-71-676 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 2514 ULO 100' Pipe 6-71-676 3.21E-05 7.52E-07 0.00E+00 0.00E+00 5.72E-10 1.49E-04 2.60E-05 6.59E-05 4.98E-05 3.12E-04 0.00E+00 8.17E-05 3.89E-05 4.37E-06 6.91E-05 3.09E-11 1.47E-08 1751 ULO 100' Pipe 6-71-681 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 2515 ULO 100' Pipe 6-71-681 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 1752 ULO 100' Pipe 6-71-682 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 2516 ULO 100' Pipe 6-71-682 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 1753 ULO 100' Pipe 6-71-683 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 2517 ULO 100' Pipe 6-71-683 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 1754 ULO 100' Pipe 6-71-684 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 2518 ULO 100' Pipe 6-71-684 1.34E-07 3.13E-09 0.00E+00 0.00E+00 2.38E-12 6.21E-07 1.08E-07 2.74E-07 2.07E-07 1.30E-06 0.00E+00 3.40E-07 1.62E-07 1.82E-08 2.88E-07 1.29E-13 6.13E-11 1755 ULO 100' Pipe 6-71-687 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 2519 ULO 100' Pipe 6-71-687 5.35E-05 1.25E-06 0.00E+00 0.00E+00 9.53E-10 2.48E-04 4.33E-05 1.10E-04 8.30E-05 5.19E-04 0.00E+00 1.36E-04 6.48E-05 7.28E-06 1.15E-04 5.14E-11 2.45E-08 1756 ULO 100' Pipe 6-71-688 1.60E-04 3.75E-06 0.00E+00 0.00E+00 2.85E-09 7.44E-04 1.30E-04 3.29E-04 2.48E-04 1.55E-03 0.00E+00 4.07E-04 1.94E-04 2.18E-05 3.45E-04 1.54E-10 7.34E-08 2520 ULO 100' Pipe 6-71-688 1.60E-04 3.75E-06 0.00E+00 0.00E+00 2.85E-09 7.44E-04 1.30E-04 3.29E-04 2.48E-04 1.55E-03 0.00E+00 4.07E-04 1.94E-04 2.18E-05 3.45E-04 1.54E-10 7.34E-08 1757 ULO 100' Pipe 6-71-689 4.82E-05 1.13E-06 0.00E+00 0.00E+00 8.57E-10 2.24E-04 3.90E-05 9.88E-05 7.47E-05 4.67E-04 0.00E+00 1.22E-04 5.83E-05 6.55E-06 1.04E-04 4.62E-11 2.21E-08 2521 ULO 100' Pipe 6-71-689 4.82E-05 1.13E-06 0.00E+00 0.00E+00 8.57E-10 2.24E-04 3.90E-05 9.88E-05 7.47E-05 4.67E-04 0.00E+00 1.22E-04 5.83E-05 6.55E-06 1.04E-04 4.62E-11 2.21E-08 1758 ULO 100' Pipe 6-71-693 5.35E-06 1.25E-07 0.00E+00 0.00E+00 9.53E-11 2.48E-05 4.33E-06 1.10E-05 8.30E-06 5.19E-05 0.00E+00 1.36E-05 6.48E-06 7.28E-07 1.15E-05 5.14E-12 2.45E-09 2522 ULO 100' Pipe 6-71-693 5.35E-06 1.25E-07 0.00E+00 0.00E+00 9.53E-11 2.48E-05 4.33E-06 1.10E-05 8.30E-06 5.19E-05 0.00E+00 1.36E-05 6.48E-06 7.28E-07 1.15E-05 5.14E-12 2.45E-09 1759 ULO 100' Pipe 6-71-694 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10 2523 ULO 100' Pipe 6-71-694 1.60E-06 3.75E-08 0.00E+00 0.00E+00 2.85E-11 7.44E-06 1.30E-06 3.29E-06 2.48E-06 1.55E-05 0.00E+00 4.07E-06 1.94E-06 2.18E-07 3.45E-06 1.54E-12 7.34E-10
WVDP-606 Rev. 1 Page 43 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1760 ULO 100' Pipe 6-71-706 1.18E-05 2.77E-07 0.00E+00 0.00E+00 2.10E-10 5.49E-05 9.57E-06 2.42E-05 1.83E-05 1.15E-04 0.00E+00 3.00E-05 1.43E-05 1.61E-06 2.54E-05 1.14E-11 5.42E-09 2524 ULO 100' Pipe 6-71-706 1.18E-05 2.77E-07 0.00E+00 0.00E+00 2.10E-10 5.49E-05 9.57E-06 2.42E-05 1.83E-05 1.15E-04 0.00E+00 3.00E-05 1.43E-05 1.61E-06 2.54E-05 1.14E-11 5.42E-09 1761 ULO 100' Pipe 6-71-708 3.21E-06 7.52E-08 0.00E+00 0.00E+00 5.72E-11 1.49E-05 2.60E-06 6.59E-06 4.98E-06 3.12E-05 0.00E+00 8.17E-06 3.89E-06 4.37E-07 6.91E-06 3.09E-12 1.47E-09 2525 ULO 100' Pipe 6-71-708 3.21E-06 7.52E-08 0.00E+00 0.00E+00 5.72E-11 1.49E-05 2.60E-06 6.59E-06 4.98E-06 3.12E-05 0.00E+00 8.17E-06 3.89E-06 4.37E-07 6.91E-06 3.09E-12 1.47E-09 1762 ULO 100' Pipe 6-71-709 2.89E-07 6.77E-09 0.00E+00 0.00E+00 5.15E-12 1.34E-06 2.34E-07 5.93E-07 4.48E-07 2.80E-06 0.00E+00 7.35E-07 3.50E-07 3.93E-08 6.22E-07 2.78E-13 1.32E-10 2526 ULO 100' Pipe 6-71-709 2.89E-07 6.77E-09 0.00E+00 0.00E+00 5.15E-12 1.34E-06 2.34E-07 5.93E-07 4.48E-07 2.80E-06 0.00E+00 7.35E-07 3.50E-07 3.93E-08 6.22E-07 2.78E-13 1.32E-10 1763 ULO 100' Pipe 6-71-710 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 2527 ULO 100' Pipe 6-71-710 5.35E-07 1.25E-08 0.00E+00 0.00E+00 9.53E-12 2.48E-06 4.33E-07 1.10E-06 8.30E-07 5.19E-06 0.00E+00 1.36E-06 6.48E-07 7.28E-08 1.15E-06 5.14E-13 2.45E-10 1764 ULO 100' Pipe 6-DW-132 5.35E-08 1.25E-09 0.00E+00 0.00E+00 9.53E-13 2.48E-07 4.33E-08 1.10E-07 8.30E-08 5.19E-07 0.00E+00 1.36E-07 6.48E-08 7.28E-09 1.15E-07 5.14E-14 2.45E-11 2528 ULO 100' Pipe 6-DW-132 5.35E-08 1.25E-09 0.00E+00 0.00E+00 9.53E-13 2.48E-07 4.33E-08 1.10E-07 8.30E-08 5.19E-07 0.00E+00 1.36E-07 6.48E-08 7.28E-09 1.15E-07 5.14E-14 2.45E-11 1765 ULO 100' Pipe 6-DW-133 2.68E-06 6.26E-08 0.00E+00 0.00E+00 4.77E-11 1.24E-05 2.17E-06 5.49E-06 4.15E-06 2.59E-05 0.00E+00 6.80E-06 3.24E-06 3.64E-07 5.76E-06 2.57E-12 1.23E-09 2529 ULO 100' Pipe 6-DW-133 2.68E-06 6.26E-08 0.00E+00 0.00E+00 4.77E-11 1.24E-05 2.17E-06 5.49E-06 4.15E-06 2.59E-05 0.00E+00 6.80E-06 3.24E-06 3.64E-07 5.76E-06 2.57E-12 1.23E-09 1766 ULO 100' Pipe 6-DW-134 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 2530 ULO 100' Pipe 6-DW-134 1.07E-07 2.52E-09 0.00E+00 0.00E+00 1.91E-12 4.99E-07 8.70E-08 2.20E-07 1.67E-07 1.04E-06 0.00E+00 2.73E-07 1.30E-07 1.46E-08 2.31E-07 1.03E-13 4.92E-11 806 Uranium Product Cell (UPC)
Ceiling 2.60E-05 2.48E-04 2.29E-09 4.47E-08 9.54E-08 9.12E-06 9.44E-06 4.73E-06 3.61E-06 1.09E-06 3.98E-07 1.85E-07 8.84E-08 1.42E-09 1.23E-08 2.50E-11 1.19E-08 804 Uranium Product Cell (UPC)
E Wall 7.43E-06 7.09E-05 6.54E-10 1.28E-08 2.73E-08 2.61E-06 2.70E-06 1.35E-06 1.03E-06 3.11E-07 1.14E-07 5.27E-08 2.53E-08 4.06E-10 3.51E-09 7.13E-12 3.40E-09 802 Uranium Product Cell (UPC)
N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 803 Uranium Product Cell (UPC)
S Wall 6.56E-06 6.25E-05 5.77E-10 1.13E-08 2.41E-08 2.30E-06 2.38E-06 1.19E-06 9.11E-07 2.75E-07 1.00E-07 4.65E-08 2.23E-08 3.59E-10 3.10E-09 6.29E-12 3.00E-09 1209 Uranium Product Cell (UPC)
Tank 5D-15A Compartment #1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1210 Uranium Product Cell (UPC)
Tank 5D-15A Compartment #2 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1208 Uranium Product Cell (UPC)
Tank 5D-15B 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 805 Uranium Product Cell (UPC)
W Wall 1.25E-05 1.19E-04 1.10E-09 2.15E-08 4.60E-08 4.40E-06 4.55E-06 2.28E-06 1.74E-06 5.25E-07 1.92E-07 8.89E-08 4.26E-08 6.85E-10 5.92E-09 1.20E-11 5.74E-09 2394 Uranium Product Cell (UPC)
Pipe 15CH609 4.99E-08 4.76E-07 4.39E-12 8.58E-11 1.83E-10 1.75E-08 1.81E-08 9.08E-09 6.94E-09 2.09E-09 7.64E-10 3.54E-10 1.70E-10 2.73E-12 2.36E-11 4.79E-14 2.29E-11 2395 Uranium Product Cell (UPC)
Pipe 15P1411 1.24E-09 1.19E-08 1.09E-13 2.14E-12 4.56E-12 4.36E-10 4.51E-10 2.26E-10 1.73E-10 5.21E-11 1.90E-11 8.82E-12 4.23E-12 6.80E-14 5.88E-13 1.19E-15 5.69E-13 2397 Uranium Product Cell (UPC)
Pipe 15V951 2.34E-09 2.24E-08 2.06E-13 4.03E-12 8.60E-12 8.23E-10 8.51E-10 4.27E-10 3.26E-10 9.82E-11 3.59E-11 1.66E-11 7.97E-12 1.28E-13 1.11E-12 2.25E-15 1.07E-12 2398 Uranium Product Cell (UPC)
Pipe 15V957 3.99E-04 3.81E-03 3.51E-08 6.87E-07 1.47E-06 1.40E-04 1.45E-04 7.27E-05 5.55E-05 1.67E-05 6.11E-06 2.84E-06 1.36E-06 2.18E-08 1.89E-07 3.83E-10 1.83E-07 2400 Uranium Product Cell (UPC)
Pipe 5J305A 6.50E-11 6.20E-10 5.72E-15 1.12E-13 2.39E-13 2.28E-11 2.36E-11 1.18E-11 9.03E-12 2.72E-12 9.94E-13 4.61E-13 2.21E-13 3.55E-15 3.07E-14 6.24E-17 2.98E-14 2401 Uranium Product Cell (UPC)
Pipe 5J305B 6.50E-11 6.20E-10 5.72E-15 1.12E-13 2.39E-13 2.28E-11 2.36E-11 1.18E-11 9.03E-12 2.72E-12 9.94E-13 4.61E-13 2.21E-13 3.55E-15 3.07E-14 6.24E-17 2.98E-14 2402 Uranium Product Cell (UPC)
Pipe 5J305C 6.50E-11 6.20E-10 5.72E-15 1.12E-13 2.39E-13 2.28E-11 2.36E-11 1.18E-11 9.03E-12 2.72E-12 9.94E-13 4.61E-13 2.21E-13 3.55E-15 3.07E-14 6.24E-17 2.98E-14 2403 Uranium Product Cell (UPC)
Pipe 5J308A 7.28E-07 6.94E-06 6.40E-11 1.25E-09 2.67E-09 2.55E-07 2.64E-07 1.32E-07 1.01E-07 3.05E-08 1.11E-08 5.17E-09 2.47E-09 3.98E-11 3.44E-10 6.99E-13 3.33E-10 2404 Uranium Product Cell (UPC)
Pipe 5J308B 2.08E-08 1.98E-07 1.83E-12 3.57E-11 7.63E-11 7.29E-09 7.54E-09 3.78E-09 2.89E-09 8.71E-10 3.18E-10 1.48E-10 7.06E-11 1.14E-12 9.83E-12 1.99E-14 9.52E-12 2405 Uranium Product Cell (UPC)
Pipe 5J308C 1.04E-08 9.96E-08 9.18E-13 1.80E-11 3.83E-11 3.66E-09 3.79E-09 1.90E-09 1.45E-09 4.37E-10 1.60E-10 7.41E-11 3.55E-11 5.71E-13 4.94E-12 1.00E-14 4.78E-12
WVDP-606 Rev. 1 Page 44 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2406 Uranium Product Cell (UPC)
Pipe 5J310A 2.60E-09 2.48E-08 2.29E-13 4.47E-12 9.54E-12 9.12E-10 9.44E-10 4.73E-10 3.61E-10 1.09E-10 3.98E-11 1.85E-11 8.84E-12 1.42E-13 1.23E-12 2.50E-15 1.19E-12 2407 Uranium Product Cell (UPC)
Pipe 5J310B 2.60E-09 2.48E-08 2.29E-13 4.47E-12 9.54E-12 9.12E-10 9.44E-10 4.73E-10 3.61E-10 1.09E-10 3.98E-11 1.85E-11 8.84E-12 1.42E-13 1.23E-12 2.50E-15 1.19E-12 2408 Uranium Product Cell (UPC)
Pipe 5J310C 2.60E-09 2.48E-08 2.29E-13 4.47E-12 9.54E-12 9.12E-10 9.44E-10 4.73E-10 3.61E-10 1.09E-10 3.98E-11 1.85E-11 8.84E-12 1.42E-13 1.23E-12 2.50E-15 1.19E-12 2409 Uranium Product Cell (UPC)
Pipe 5J397B 3.90E-07 3.72E-06 3.43E-11 6.71E-10 1.43E-09 1.37E-07 1.42E-07 7.10E-08 5.42E-08 1.63E-08 5.97E-09 2.77E-09 1.33E-09 2.13E-11 1.84E-10 3.74E-13 1.79E-10 2410 Uranium Product Cell (UPC)
Pipe 5P306 2.34E-06 2.24E-05 2.06E-10 4.03E-09 8.60E-09 8.23E-07 8.51E-07 4.27E-07 3.26E-07 9.82E-08 3.59E-08 1.66E-08 7.97E-09 1.28E-10 1.11E-09 2.25E-12 1.07E-09 2411 Uranium Product Cell (UPC)
Pipe 5P312 1.24E-07 1.19E-06 1.09E-11 2.14E-10 4.56E-10 4.36E-08 4.51E-08 2.26E-08 1.73E-08 5.21E-09 1.90E-09 8.82E-10 4.23E-10 6.80E-12 5.88E-11 1.19E-13 5.69E-11 2412 Uranium Product Cell (UPC)
Pipe 5P330 2.18E-06 2.08E-05 1.92E-10 3.75E-09 8.01E-09 7.66E-07 7.92E-07 3.97E-07 3.03E-07 9.14E-08 3.34E-08 1.55E-08 7.42E-09 1.19E-10 1.03E-09 2.09E-12 9.99E-10 2413 Uranium Product Cell (UPC)
Pipe 5P342 7.49E-07 7.14E-06 6.59E-11 1.29E-09 2.75E-09 2.63E-07 2.72E-07 1.36E-07 1.04E-07 3.14E-08 1.15E-08 5.31E-09 2.55E-09 4.09E-11 3.54E-10 7.19E-13 3.43E-10 2414 Uranium Product Cell (UPC)
Pipe 5P362 1.99E-06 1.90E-05 1.75E-10 3.43E-09 7.31E-09 6.99E-07 7.23E-07 3.63E-07 2.77E-07 8.35E-08 3.05E-08 1.41E-08 6.77E-09 1.09E-10 9.42E-10 1.91E-12 9.13E-10 2415 Uranium Product Cell (UPC)
Pipe 5P370 2.60E-06 2.48E-05 2.29E-10 4.47E-09 9.54E-09 9.12E-07 9.44E-07 4.73E-07 3.61E-07 1.09E-07 3.98E-08 1.85E-08 8.84E-09 1.42E-10 1.23E-09 2.50E-12 1.19E-09 2416 Uranium Product Cell (UPC)
Pipe 5P375 2.98E-06 2.84E-05 2.62E-10 5.12E-09 1.09E-08 1.05E-06 1.08E-06 5.42E-07 4.14E-07 1.25E-07 4.56E-08 2.12E-08 1.01E-08 1.63E-10 1.41E-09 2.86E-12 1.36E-09 2417 Uranium Product Cell (UPC)
Pipe 5P377 2.98E-06 2.84E-05 2.62E-10 5.12E-09 1.09E-08 1.05E-06 1.08E-06 5.42E-07 4.14E-07 1.25E-07 4.56E-08 2.12E-08 1.01E-08 1.63E-10 1.41E-09 2.86E-12 1.36E-09 2418 Uranium Product Cell (UPC)
Pipe 5P379 4.16E-08 3.96E-07 3.66E-12 7.15E-11 1.53E-10 1.46E-08 1.51E-08 7.56E-09 5.78E-09 1.74E-09 6.36E-10 2.95E-10 1.41E-10 2.27E-12 1.97E-11 3.99E-14 1.90E-11 2419 Uranium Product Cell (UPC)
Pipe 5P380A 3.63E-08 3.47E-07 3.20E-12 6.25E-11 1.33E-10 1.28E-08 1.32E-08 6.61E-09 5.05E-09 1.52E-09 5.56E-10 2.58E-10 1.24E-10 1.99E-12 1.72E-11 3.49E-14 1.66E-11 2420 Uranium Product Cell (UPC)
Pipe 5P380A 1.45E-08 1.38E-07 1.28E-12 2.50E-11 5.33E-11 5.10E-09 5.27E-09 2.64E-09 2.02E-09 6.08E-10 2.22E-10 1.03E-10 4.94E-11 7.94E-13 6.87E-12 1.39E-14 6.65E-12 2421 Uranium Product Cell (UPC)
Pipe 5P380B 9.10E-09 8.68E-08 8.01E-13 1.56E-11 3.34E-11 3.19E-09 3.30E-09 1.66E-09 1.26E-09 3.81E-10 1.39E-10 6.46E-11 3.09E-11 4.98E-13 4.30E-12 8.73E-15 4.17E-12 2422 Uranium Product Cell (UPC)
Pipe 5P380B 3.63E-09 3.47E-08 3.20E-13 6.25E-12 1.33E-11 1.28E-09 1.32E-09 6.61E-10 5.05E-10 1.52E-10 5.56E-11 2.58E-11 1.24E-11 1.99E-13 1.72E-12 3.49E-15 1.66E-12 2423 Uranium Product Cell (UPC)
Pipe 5P380C 9.10E-09 8.68E-08 8.01E-13 1.56E-11 3.34E-11 3.19E-09 3.30E-09 1.66E-09 1.26E-09 3.81E-10 1.39E-10 6.46E-11 3.09E-11 4.98E-13 4.30E-12 8.73E-15 4.17E-12 2424 Uranium Product Cell (UPC)
Pipe 5P380C 3.63E-09 3.47E-08 3.20E-13 6.25E-12 1.33E-11 1.28E-09 1.32E-09 6.61E-10 5.05E-10 1.52E-10 5.56E-11 2.58E-11 1.24E-11 1.99E-13 1.72E-12 3.49E-15 1.66E-12 2425 Uranium Product Cell (UPC)
Pipe 5P382 4.36E-06 4.16E-05 3.84E-10 7.51E-09 1.60E-08 1.53E-06 1.58E-06 7.94E-07 6.07E-07 1.83E-07 6.68E-08 3.10E-08 1.48E-08 2.39E-10 2.06E-09 4.19E-12 2.00E-09 2426 Uranium Product Cell (UPC)
Pipe 5P392 5.20E-10 4.96E-09 4.58E-14 8.94E-13 1.91E-12 1.82E-10 1.89E-10 9.46E-11 7.23E-11 2.18E-11 7.95E-12 3.69E-12 1.77E-12 2.84E-14 2.46E-13 4.99E-16 2.38E-13 2427 Uranium Product Cell (UPC)
Pipe 5P398 2.50E-06 2.38E-05 2.20E-10 4.29E-09 9.16E-09 8.76E-07 9.06E-07 4.54E-07 3.47E-07 1.05E-07 3.82E-08 1.77E-08 8.48E-09 1.36E-10 1.18E-09 2.40E-12 1.14E-09 2428 Uranium Product Cell (UPC)
Pipe 5P399 3.12E-06 2.98E-05 2.75E-10 5.37E-09 1.15E-08 1.10E-06 1.13E-06 5.68E-07 4.34E-07 1.31E-07 4.78E-08 2.22E-08 1.06E-08 1.71E-10 1.48E-09 3.00E-12 1.43E-09 2429 Uranium Product Cell (UPC)
Pipe 5P400 1.24E-06 1.19E-05 1.09E-10 2.14E-09 4.56E-09 4.36E-07 4.51E-07 2.26E-07 1.73E-07 5.21E-08 1.90E-08 8.82E-09 4.23E-09 6.80E-11 5.88E-10 1.19E-12 5.69E-10 2430 Uranium Product Cell (UPC)
Pipe 5P402 1.87E-06 1.78E-05 1.64E-10 3.21E-09 6.86E-09 6.56E-07 6.78E-07 3.40E-07 2.60E-07 7.83E-08 2.86E-08 1.33E-08 6.35E-09 1.02E-10 8.84E-10 1.79E-12 8.56E-10 2431 Uranium Product Cell (UPC)
Pipe 5P416A 1.30E-07 1.24E-06 1.14E-11 2.24E-10 4.77E-10 4.56E-08 4.72E-08 2.37E-08 1.81E-08 5.45E-09 1.99E-09 9.23E-10 4.42E-10 7.11E-12 6.15E-11 1.25E-13 5.95E-11 2432 Uranium Product Cell (UPC)
Pipe 5P416B 3.24E-08 3.10E-07 2.86E-12 5.58E-11 1.19E-10 1.14E-08 1.18E-08 5.91E-09 4.51E-09 1.36E-09 4.96E-10 2.30E-10 1.10E-10 1.77E-12 1.53E-11 3.11E-14 1.49E-11 2433 Uranium Product Cell (UPC)
Pipe 5P416C 3.24E-08 3.10E-07 2.86E-12 5.58E-11 1.19E-10 1.14E-08 1.18E-08 5.91E-09 4.51E-09 1.36E-09 4.96E-10 2.30E-10 1.10E-10 1.77E-12 1.53E-11 3.11E-14 1.49E-11 2434 Uranium Product Cell (UPC)
Pipe 5P545A 1.04E-07 9.96E-07 9.18E-12 1.80E-10 3.83E-10 3.66E-08 3.79E-08 1.90E-08 1.45E-08 4.37E-09 1.60E-09 7.41E-10 3.55E-10 5.71E-12 4.94E-11 1.00E-13 4.78E-11 2435 Uranium Product Cell (UPC)
Pipe 5P545B 2.60E-08 2.48E-07 2.29E-12 4.47E-11 9.54E-11 9.12E-09 9.44E-09 4.73E-09 3.61E-09 1.09E-09 3.98E-10 1.85E-10 8.84E-11 1.42E-12 1.23E-11 2.50E-14 1.19E-11
WVDP-606 Rev. 1 Page 45 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2436 Uranium Product Cell (UPC)
Pipe 5P545C 3.90E-08 3.72E-07 3.43E-12 6.71E-11 1.43E-10 1.37E-08 1.42E-08 7.10E-09 5.42E-09 1.63E-09 5.97E-10 2.77E-10 1.33E-10 2.13E-12 1.84E-11 3.74E-14 1.79E-11 2437 Uranium Product Cell (UPC)
Pipe 5P547A 2.34E-06 2.24E-05 2.06E-10 4.03E-09 8.60E-09 8.23E-07 8.51E-07 4.27E-07 3.26E-07 9.82E-08 3.59E-08 1.66E-08 7.97E-09 1.28E-10 1.11E-09 2.25E-12 1.07E-09 2438 Uranium Product Cell (UPC)
Pipe 5P547B 3.90E-09 3.72E-08 3.43E-13 6.71E-12 1.43E-11 1.37E-09 1.42E-09 7.10E-10 5.42E-10 1.63E-10 5.97E-11 2.77E-11 1.33E-11 2.13E-13 1.84E-12 3.74E-15 1.79E-12 2439 Uranium Product Cell (UPC)
Pipe 5P547C 3.90E-09 3.72E-08 3.43E-13 6.71E-12 1.43E-11 1.37E-09 1.42E-09 7.10E-10 5.42E-10 1.63E-10 5.97E-11 2.77E-11 1.33E-11 2.13E-13 1.84E-12 3.74E-15 1.79E-12 2440 Uranium Product Cell (UPC)
Pipe 5UA319 5.46E-08 5.20E-07 4.80E-12 9.38E-11 2.00E-10 1.91E-08 1.98E-08 9.93E-09 7.58E-09 2.29E-09 8.35E-10 3.87E-10 1.85E-10 2.98E-12 2.58E-11 5.24E-14 2.50E-11 2441 Uranium Product Cell (UPC)
Pipe 5UA337 1.24E-07 1.19E-06 1.09E-11 2.14E-10 4.56E-10 4.36E-08 4.51E-08 2.26E-08 1.73E-08 5.21E-09 1.90E-09 8.82E-10 4.23E-10 6.80E-12 5.88E-11 1.19E-13 5.69E-11 2442 Uranium Product Cell (UPC)
Pipe 5UA352 4.16E-08 3.96E-07 3.66E-12 7.15E-11 1.53E-10 1.46E-08 1.51E-08 7.56E-09 5.78E-09 1.74E-09 6.36E-10 2.95E-10 1.41E-10 2.27E-12 1.97E-11 3.99E-14 1.90E-11 2443 Uranium Product Cell (UPC)
Pipe 6-71-095 1.87E-06 1.78E-05 1.64E-10 3.21E-09 6.86E-09 6.56E-07 6.78E-07 3.40E-07 2.60E-07 7.83E-08 2.86E-08 1.33E-08 6.35E-09 1.02E-10 8.84E-10 1.79E-12 8.56E-10 2444 Uranium Product Cell (UPC)
Pipe 6-71-110 7.80E-07 7.44E-06 6.86E-11 1.34E-09 2.86E-09 2.74E-07 2.83E-07 1.42E-07 1.08E-07 3.27E-08 1.19E-08 5.54E-09 2.65E-09 4.27E-11 3.69E-10 7.49E-13 3.57E-10 2445 Uranium Product Cell (UPC)
Pipe 6-71-135 3.74E-06 3.57E-05 3.29E-10 6.43E-09 1.37E-08 1.31E-06 1.36E-06 6.80E-07 5.20E-07 1.57E-07 5.72E-08 2.65E-08 1.27E-08 2.04E-10 1.77E-09 3.59E-12 1.71E-09 2446 Uranium Product Cell (UPC)
Pipe 6-71-136 1.38E-08 1.31E-07 1.21E-12 2.37E-11 5.05E-11 4.83E-09 4.99E-09 2.50E-09 1.91E-09 5.76E-10 2.10E-10 9.77E-11 4.68E-11 7.53E-13 6.51E-12 1.32E-14 6.30E-12 2447 Uranium Product Cell (UPC)
Pipe 6-71-136 2.06E-08 1.96E-07 1.81E-12 3.54E-11 7.56E-11 7.23E-09 7.47E-09 3.75E-09 2.86E-09 8.63E-10 3.15E-10 1.46E-10 7.00E-11 1.13E-12 9.74E-12 1.98E-14 9.43E-12 2448 Uranium Product Cell (UPC)
Pipe 6-71-138 9.35E-07 8.92E-06 8.23E-11 1.61E-09 3.43E-09 3.28E-07 3.40E-07 1.70E-07 1.30E-07 3.92E-08 1.43E-08 6.64E-09 3.18E-09 5.12E-11 4.42E-10 8.98E-13 4.28E-10 2449 Uranium Product Cell (UPC)
Pipe 6-71-203 3.12E-09 2.98E-08 2.75E-13 5.37E-12 1.15E-11 1.10E-09 1.13E-09 5.68E-10 4.34E-10 1.31E-10 4.78E-11 2.22E-11 1.06E-11 1.71E-13 1.48E-12 3.00E-15 1.43E-12 2450 Uranium Product Cell (UPC)
Pipe 6-71-203 4.68E-09 4.46E-08 4.12E-13 8.05E-12 1.72E-11 1.64E-09 1.70E-09 8.51E-10 6.50E-10 1.96E-10 7.16E-11 3.32E-11 1.59E-11 2.56E-13 2.21E-12 4.49E-15 2.14E-12 2451 Uranium Product Cell (UPC)
Pipe 6-71-308 1.24E-09 1.19E-08 1.09E-13 2.14E-12 4.56E-12 4.36E-10 4.51E-10 2.26E-10 1.73E-10 5.21E-11 1.90E-11 8.82E-12 4.23E-12 6.80E-14 5.88E-13 1.19E-15 5.69E-13 2452 Uranium Product Cell (UPC)
Pipe 6-71-313 1.24E-07 1.19E-06 1.09E-11 2.14E-10 4.56E-10 4.36E-08 4.51E-08 2.26E-08 1.73E-08 5.21E-09 1.90E-09 8.82E-10 4.23E-10 6.80E-12 5.88E-11 1.19E-13 5.69E-11 2453 Uranium Product Cell (UPC)
Pipe 6-71-313 1.87E-07 1.78E-06 1.64E-11 3.21E-10 6.86E-10 6.56E-08 6.78E-08 3.40E-08 2.60E-08 7.83E-09 2.86E-09 1.33E-09 6.35E-10 1.02E-11 8.84E-11 1.79E-13 8.56E-11 2454 Uranium Product Cell (UPC)
Pipe 6-71-314 6.23E-08 5.95E-07 5.49E-12 1.07E-10 2.29E-10 2.19E-08 2.26E-08 1.13E-08 8.66E-09 2.61E-09 9.54E-10 4.43E-10 2.12E-10 3.41E-12 2.95E-11 5.98E-14 2.85E-11 2455 Uranium Product Cell (UPC)
Pipe 6-71-315 1.56E-07 1.48E-06 1.37E-11 2.68E-10 5.71E-10 5.46E-08 5.65E-08 2.83E-08 2.16E-08 6.52E-09 2.38E-09 1.10E-09 5.29E-10 8.51E-12 7.36E-11 1.49E-13 7.13E-11 2456 Uranium Product Cell (UPC)
Pipe 6-71-390 1.24E-08 1.19E-07 1.09E-12 2.14E-11 4.56E-11 4.36E-09 4.51E-09 2.26E-09 1.73E-09 5.21E-10 1.90E-10 8.82E-11 4.23E-11 6.80E-13 5.88E-12 1.19E-14 5.69E-12 2457 Uranium Product Cell (UPC)
Pipe 6-71-390 1.87E-08 1.78E-07 1.64E-12 3.21E-11 6.86E-11 6.56E-09 6.78E-09 3.40E-09 2.60E-09 7.83E-10 2.86E-10 1.33E-10 6.35E-11 1.02E-12 8.84E-12 1.79E-14 8.56E-12 2458 Uranium Product Cell (UPC)
Pipe 6-71-631 4.16E-09 3.96E-08 3.66E-13 7.15E-12 1.53E-11 1.46E-09 1.51E-09 7.56E-10 5.78E-10 1.74E-10 6.36E-11 2.95E-11 1.41E-11 2.27E-13 1.97E-12 3.99E-15 1.90E-12 2459 Uranium Product Cell (UPC)
Pipe 6-71-631 4.16E-09 3.96E-08 3.66E-13 7.15E-12 1.53E-11 1.46E-09 1.51E-09 7.56E-10 5.78E-10 1.74E-10 6.36E-11 2.95E-11 1.41E-11 2.27E-13 1.97E-12 3.99E-15 1.90E-12 2460 Uranium Product Cell (UPC)
Pipe 6-71-632 2.08E-09 1.98E-08 1.83E-13 3.57E-12 7.63E-12 7.29E-10 7.54E-10 3.78E-10 2.89E-10 8.71E-11 3.18E-11 1.48E-11 7.06E-12 1.14E-13 9.83E-13 1.99E-15 9.52E-13 2461 Uranium Product Cell (UPC)
Pipe 6-71-632 2.08E-09 1.98E-08 1.83E-13 3.57E-12 7.63E-12 7.29E-10 7.54E-10 3.78E-10 2.89E-10 8.71E-11 3.18E-11 1.48E-11 7.06E-12 1.14E-13 9.83E-13 1.99E-15 9.52E-13 2462 Uranium Product Cell (UPC)
Pipe 6-71-633 1.04E-07 9.96E-07 9.18E-12 1.80E-10 3.83E-10 3.66E-08 3.79E-08 1.90E-08 1.45E-08 4.37E-09 1.60E-09 7.41E-10 3.55E-10 5.71E-12 4.94E-11 1.00E-13 4.78E-11 2463 Uranium Product Cell (UPC)
Pipe 6-71-633 1.04E-07 9.96E-07 9.18E-12 1.80E-10 3.83E-10 3.66E-08 3.79E-08 1.90E-08 1.45E-08 4.37E-09 1.60E-09 7.41E-10 3.55E-10 5.71E-12 4.94E-11 1.00E-13 4.78E-11 2464 Uranium Product Cell (UPC)
Pipe 6-71-634 1.45E-07 1.38E-06 1.28E-11 2.50E-10 5.33E-10 5.10E-08 5.27E-08 2.64E-08 2.02E-08 6.08E-09 2.22E-09 1.03E-09 4.94E-10 7.94E-12 6.87E-11 1.39E-13 6.65E-11 1025 UWA 114' Ceiling 4.97E-05 1.83E-05 2.46E-09 6.17E-08 1.46E-09 2.61E-06 7.96E-07 5.97E-07 4.50E-07 7.86E-06 5.22E-07 4.10E-08 1.91E-08 8.90E-10 1.28E-08 4.78E-11 2.28E-08 1031 UWA 114' Ceiling 1.98E-06 7.25E-07 9.76E-11 2.45E-09 5.81E-11 1.04E-07 3.16E-08 2.37E-08 1.79E-08 3.12E-07 2.07E-08 1.63E-09 7.58E-10 3.54E-11 5.10E-10 1.90E-12 9.05E-10
WVDP-606 Rev. 1 Page 46 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1023 UWA 114' E Wall 2.40E-07 8.81E-08 1.19E-11 2.98E-10 7.05E-12 1.26E-08 3.84E-09 2.88E-09 2.17E-09 3.79E-08 2.52E-09 1.98E-10 9.21E-11 4.29E-12 6.19E-11 2.30E-13 1.10E-10 1029 UWA 114' E Wall 1.39E-08 5.10E-09 6.87E-13 1.72E-11 4.09E-13 7.30E-10 2.22E-10 1.67E-10 1.26E-10 2.20E-09 1.46E-10 1.15E-11 5.34E-12 2.49E-13 3.59E-12 1.33E-14 6.37E-12 1026 UWA 114' Floor 3.74E-05 1.37E-05 1.85E-09 4.64E-08 1.10E-09 1.96E-06 5.98E-07 4.49E-07 3.38E-07 5.91E-06 3.93E-07 3.08E-08 1.44E-08 6.69E-10 9.64E-09 3.59E-11 1.71E-08 1032 UWA 114' Floor 7.90E-08 2.90E-08 3.90E-12 9.80E-11 2.32E-12 4.15E-09 1.26E-09 9.48E-10 7.15E-10 1.25E-08 8.30E-10 6.51E-11 3.03E-11 1.41E-12 2.04E-11 7.58E-14 3.62E-11 1021 UWA 114' N Wall 3.94E-05 1.44E-05 1.94E-09 4.88E-08 1.16E-09 2.07E-06 6.30E-07 4.72E-07 3.56E-07 6.22E-06 4.13E-07 3.24E-08 1.51E-08 7.04E-10 1.02E-08 3.78E-11 1.80E-08 1027 UWA 114' N Wall 2.21E-07 8.11E-08 1.09E-11 2.74E-10 6.50E-12 1.16E-08 3.53E-09 2.65E-09 2.00E-09 3.49E-08 2.32E-09 1.82E-10 8.48E-11 3.95E-12 5.70E-11 2.12E-13 1.01E-10 1022 UWA 114' S Wall 3.49E-05 1.28E-05 1.72E-09 4.33E-08 1.03E-09 1.83E-06 5.58E-07 4.19E-07 3.16E-07 5.51E-06 3.66E-07 2.88E-08 1.34E-08 6.25E-10 9.00E-09 3.35E-11 1.60E-08 1028 UWA 114' S Wall 1.38E-06 5.07E-07 6.83E-11 1.71E-09 4.06E-11 7.26E-08 2.21E-08 1.66E-08 1.25E-08 2.18E-07 1.45E-08 1.14E-09 5.31E-10 2.47E-11 3.57E-10 1.33E-12 6.33E-10 1024 UWA 114' W Wall 7.21E-06 2.64E-06 3.56E-10 8.93E-09 2.12E-10 3.78E-07 1.15E-07 8.65E-08 6.52E-08 1.14E-06 7.57E-08 5.94E-09 2.77E-09 1.29E-10 1.86E-09 6.92E-12 3.30E-09 1030 UWA 114' W Wall 5.53E-08 2.03E-08 2.73E-12 6.86E-11 1.63E-12 2.90E-09 8.85E-10 6.64E-10 5.00E-10 8.74E-09 5.81E-10 4.56E-11 2.12E-11 9.90E-13 1.43E-11 5.31E-14 2.53E-11 2393 UWA 114' Pipe 5DW172 1.91E-08 7.01E-09 9.43E-13 2.37E-11 5.61E-13 1.00E-09 3.05E-10 2.29E-10 1.73E-10 3.02E-09 2.00E-10 1.57E-11 7.33E-12 3.42E-13 4.93E-12 1.83E-14 8.74E-12 1794 UWA Niche 1 114' Ceiling 3.29E-03 5.45E-03 2.01E-07 4.44E-06 4.24E-08 1.12E-02 3.94E-03 2.52E-03 1.93E-03 3.75E-02 1.84E-06 1.98E-05 9.53E-06 1.45E-05 3.75E-06 3.15E-09 1.50E-06 1791 UWA Niche 1 114' E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1793 UWA Niche 1 114' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1789 UWA Niche 1 114' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1790 UWA Niche 1 114' S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1792 UWA Niche 1 114' W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1799 UWA Niche 2 114' Ceiling 4.81E-04 7.99E-04 2.94E-08 6.50E-07 6.21E-09 1.65E-03 5.77E-04 3.70E-04 2.82E-04 5.49E-03 2.69E-07 2.90E-06 1.40E-06 2.12E-06 5.49E-07 4.62E-10 2.20E-07 1798 UWA Niche 2 114' E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1800 UWA Niche 2 114' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1795 UWA Niche 2 114' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1796 UWA Niche 2 114' S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1797 UWA Niche 2 114' W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1811 UWA Niche 3 114' Ceiling 1.25E-02 1.72E-02 1.17E-06 2.62E-05 3.37E-04 9.48E-03 1.11E-03 1.49E-03 1.13E-03 1.39E-03 4.18E-05 1.01E-03 4.83E-04 2.77E-05 1.91E-04 1.20E-08 5.72E-06 1809 UWA Niche 3 114' E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1812 UWA Niche 3 114' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1807 UWA Niche 3 114' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1808 UWA Niche 3 114' S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1810 UWA Niche 3 114' W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1805 UWA Niche 4 114' Ceiling 1.82E-04 3.01E-04 1.11E-08 2.45E-07 2.34E-09 6.21E-04 2.18E-04 1.39E-04 1.06E-04 2.07E-03 1.02E-07 1.09E-06 5.27E-07 7.99E-07 2.07E-07 1.74E-10 8.32E-08 1803 UWA Niche 4 114' E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1806 UWA Niche 4 114' Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1801 UWA Niche 4 114' N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1802 UWA Niche 4 114' S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1804 UWA Niche 4 114' W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
WVDP-606 Rev. 1 Page 47 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1817 UWA Niche 5 North 114' Ceiling 1.99E-04 1.03E-04 9.71E-09 1.89E-07 1.31E-09 2.03E-05 2.67E-06 5.48E-06 2.81E-06 5.38E-05 2.73E-09 7.10E-09 6.66E-10 2.95E-10 5.02E-09 1.91E-10 9.13E-08 1815 UWA Niche 5 North 114' E Wall 8.84E-05 4.56E-05 4.31E-09 8.40E-08 5.82E-10 9.02E-06 1.19E-06 2.43E-06 1.25E-06 2.39E-05 1.21E-09 3.15E-09 2.95E-10 1.31E-10 2.23E-09 8.49E-11 4.05E-08 1818 UWA Niche 5 North 114' Floor 1.99E-04 1.03E-04 9.71E-09 1.89E-07 1.31E-09 2.03E-05 2.67E-06 5.48E-06 2.81E-06 5.38E-05 2.73E-09 7.10E-09 6.66E-10 2.95E-10 5.02E-09 1.91E-10 9.13E-08 1813 UWA Niche 5 North 114' N Wall 1.23E-04 6.36E-05 6.01E-09 1.17E-07 8.12E-10 1.26E-05 1.65E-06 3.39E-06 1.74E-06 3.33E-05 1.69E-09 4.39E-09 4.12E-10 1.83E-10 3.11E-09 1.18E-10 5.65E-08 1814 UWA Niche 5 North 114' S Wall 1.23E-04 6.36E-05 6.01E-09 1.17E-07 8.12E-10 1.26E-05 1.65E-06 3.39E-06 1.74E-06 3.33E-05 1.69E-09 4.39E-09 4.12E-10 1.83E-10 3.11E-09 1.18E-10 5.65E-08 1816 UWA Niche 5 North 114' W Wall 8.84E-05 4.56E-05 4.31E-09 8.40E-08 5.82E-10 9.02E-06 1.19E-06 2.43E-06 1.25E-06 2.39E-05 1.21E-09 3.15E-09 2.95E-10 1.31E-10 2.23E-09 8.49E-11 4.05E-08 1823 UWA Niche 5 South 114' Ceiling 1.08E-04 5.54E-05 5.24E-09 1.02E-07 7.08E-10 1.10E-05 1.44E-06 2.96E-06 1.52E-06 2.90E-05 1.47E-09 3.83E-09 3.59E-10 1.59E-10 2.71E-09 1.03E-10 4.93E-08 1821 UWA Niche 5 South 114' E Wall 4.88E-05 2.52E-05 2.38E-09 4.64E-08 3.21E-10 4.98E-06 6.55E-07 1.34E-06 6.89E-07 1.32E-05 6.69E-10 1.74E-09 1.63E-10 7.23E-11 1.23E-09 4.69E-11 2.24E-08 1824 UWA Niche 5 South 114' Floor 1.08E-04 5.54E-05 5.24E-09 1.02E-07 7.08E-10 1.10E-05 1.44E-06 2.96E-06 1.52E-06 2.90E-05 1.47E-09 3.83E-09 3.59E-10 1.59E-10 2.71E-09 1.03E-10 4.93E-08 1819 UWA Niche 5 South 114' N Wall 1.21E-04 6.22E-05 5.88E-09 1.15E-07 7.95E-10 1.23E-05 1.62E-06 3.32E-06 1.70E-06 3.26E-05 1.65E-09 4.30E-09 4.03E-10 1.79E-10 3.04E-09 1.16E-10 5.53E-08 1820 UWA Niche 5 South 114' S Wall 1.21E-04 6.22E-05 5.88E-09 1.15E-07 7.95E-10 1.23E-05 1.62E-06 3.32E-06 1.70E-06 3.26E-05 1.65E-09 4.30E-09 4.03E-10 1.79E-10 3.04E-09 1.16E-10 5.53E-08 1822 UWA Niche 5 South 114' W Wall 4.88E-05 2.52E-05 2.38E-09 4.64E-08 3.21E-10 4.98E-06 6.55E-07 1.34E-06 6.89E-07 1.32E-05 6.69E-10 1.74E-09 1.63E-10 7.23E-11 1.23E-09 4.69E-11 2.24E-08 1829 UWA Niche 6 114' Ceiling 3.12E-04 1.60E-04 1.52E-08 2.96E-07 2.05E-09 3.18E-05 4.17E-06 8.57E-06 4.39E-06 8.41E-05 4.27E-09 1.11E-08 1.04E-09 4.61E-10 7.85E-09 2.99E-10 1.43E-07 1827 UWA Niche 6 114' E Wall 1.56E-04 8.02E-05 7.59E-09 1.48E-07 1.03E-09 1.59E-05 2.09E-06 4.28E-06 2.20E-06 4.21E-05 2.13E-09 5.55E-09 5.20E-10 2.31E-10 3.93E-09 1.50E-10 7.13E-08 1830 UWA Niche 6 114' Floor 3.12E-04 1.60E-04 1.52E-08 2.96E-07 2.05E-09 3.18E-05 4.17E-06 8.57E-06 4.39E-06 8.41E-05 4.27E-09 1.11E-08 1.04E-09 4.61E-10 7.85E-09 2.99E-10 1.43E-07 1825 UWA Niche 6 114' N Wall 1.10E-04 5.64E-05 5.34E-09 1.04E-07 7.21E-10 1.12E-05 1.47E-06 3.01E-06 1.54E-06 2.96E-05 1.50E-09 3.90E-09 3.66E-10 1.62E-10 2.76E-09 1.05E-10 5.02E-08 1826 UWA Niche 6 114' S Wall 1.10E-04 5.64E-05 5.34E-09 1.04E-07 7.21E-10 1.12E-05 1.47E-06 3.01E-06 1.54E-06 2.96E-05 1.50E-09 3.90E-09 3.66E-10 1.62E-10 2.76E-09 1.05E-10 5.02E-08 1828 UWA Niche 6 114' W Wall 1.56E-04 8.02E-05 7.59E-09 1.48E-07 1.03E-09 1.59E-05 2.09E-06 4.28E-06 2.20E-06 4.21E-05 2.13E-09 5.55E-09 5.20E-10 2.31E-10 3.93E-09 1.50E-10 7.13E-08 926 UXA 144' Ceiling 2.83E-04 1.04E-04 1.40E-08 3.51E-07 8.32E-09 1.49E-05 4.53E-06 3.40E-06 2.56E-06 4.47E-05 2.97E-06 2.33E-07 1.09E-07 5.07E-09 7.30E-08 2.72E-10 1.30E-07 927 UXA 144' Ceiling 2.67E-05 9.80E-06 1.32E-09 3.31E-08 7.85E-10 1.40E-06 4.27E-07 3.20E-07 2.42E-07 4.22E-06 2.80E-07 2.20E-08 1.03E-08 4.78E-10 6.89E-09 2.56E-11 1.22E-08 687 UXA 144' E Wall 1.42E-04 5.21E-05 7.01E-09 1.76E-07 4.17E-09 7.45E-06 2.27E-06 1.70E-06 1.28E-06 2.24E-05 1.49E-06 1.17E-07 5.45E-08 2.54E-09 3.66E-08 1.36E-10 6.50E-08 727 UXA 144' E Wall 4.46E-06 1.63E-06 2.20E-10 5.52E-09 1.31E-10 2.34E-07 7.13E-08 5.35E-08 4.03E-08 7.04E-07 4.68E-08 3.67E-09 1.71E-09 7.97E-11 1.15E-09 4.28E-12 2.04E-09 689 UXA 144' Floor 3.20E-04 1.18E-04 1.58E-08 3.97E-07 9.42E-09 1.68E-05 5.13E-06 3.84E-06 2.90E-06 5.06E-05 3.36E-06 2.64E-07 1.23E-07 5.74E-09 8.27E-08 3.08E-10 1.47E-07 695 UXA 144' Floor 1.49E-05 5.45E-06 7.34E-10 1.84E-08 4.37E-10 7.80E-07 2.38E-07 1.78E-07 1.34E-07 2.35E-06 1.56E-07 1.22E-08 5.70E-09 2.66E-10 3.83E-09 1.43E-11 6.80E-09 684 UXA 144' N Wall 1.01E-05 3.70E-06 4.99E-10 1.25E-08 2.97E-10 5.30E-07 1.62E-07 1.21E-07 9.14E-08 1.60E-06 1.06E-07 8.32E-09 3.88E-09 1.81E-10 2.60E-09 9.69E-12 4.62E-09 729 UXA 144' N Wall 5.72E-04 2.10E-04 2.83E-08 7.09E-07 1.68E-08 3.00E-05 9.15E-06 6.86E-06 5.18E-06 9.04E-05 6.01E-06 4.71E-07 2.20E-07 1.02E-08 1.48E-07 5.49E-10 2.62E-07 728 UXA 144' S Wall 3.64E-05 1.34E-05 1.80E-09 4.52E-08 1.07E-09 1.91E-06 5.83E-07 4.37E-07 3.30E-07 5.76E-06 3.83E-07 3.00E-08 1.40E-08 6.52E-10 9.40E-09 3.50E-11 1.67E-08 694 UXA 144' W Wall 5.78E-06 2.12E-06 2.85E-10 7.17E-09 1.70E-10 3.03E-07 9.25E-08 6.93E-08 5.23E-08 9.13E-07 6.07E-08 4.76E-09 2.22E-09 1.03E-10 1.49E-09 5.55E-12 2.65E-09 726 UXA 144' W Wall 1.00E-04 3.68E-05 4.95E-09 1.24E-07 2.95E-09 5.26E-06 1.60E-06 1.20E-06 9.07E-07 1.58E-05 1.05E-06 8.26E-08 3.85E-08 1.79E-09 2.59E-08 9.62E-11 4.59E-08 2390 UXA 144' Pipe 15DW311 4.81E-07 1.76E-07 2.37E-11 5.96E-10 1.41E-11 2.52E-08 7.69E-09 5.77E-09 4.35E-09 7.59E-08 5.05E-09 3.96E-10 1.85E-10 8.60E-12 1.24E-10 4.61E-13 2.20E-10 1843 VEC 144' Ceiling 8.63E-04 3.17E-04 4.26E-08 1.07E-06 2.54E-08 4.53E-05 1.38E-05 1.04E-05 7.81E-06 1.36E-04 9.06E-06 7.11E-07 3.31E-07 1.55E-08 2.23E-07 8.29E-10 3.95E-07 1849 VEC 144' Ceiling 4.23E-03 1.55E-03 2.09E-07 5.24E-06 1.24E-07 2.22E-04 6.77E-05 5.07E-05 3.83E-05 6.68E-04 4.44E-05 3.48E-06 1.62E-06 7.57E-08 1.09E-06 4.06E-09 1.94E-06 1855 VEC 144' Ceiling 1.53E-05 5.61E-06 7.55E-10 1.90E-08 4.49E-10 8.03E-07 2.45E-07 1.83E-07 1.38E-07 2.42E-06 1.61E-07 1.26E-08 5.87E-09 2.74E-10 3.94E-09 1.47E-11 7.00E-09 1861 VEC 144' Ceiling 1.48E-01 5.42E-02 7.30E-06 1.83E-04 4.34E-06 7.76E-03 2.36E-03 1.77E-03 1.34E-03 2.33E-02 1.55E-03 1.22E-04 5.67E-05 2.65E-06 3.81E-05 1.42E-07 6.77E-05 1841 VEC 144' E Wall 5.94E-06 2.18E-06 2.93E-10 7.37E-09 1.75E-10 3.12E-07 9.50E-08 7.13E-08 5.38E-08 9.39E-07 6.24E-08 4.89E-09 2.28E-09 1.06E-10 1.53E-09 5.70E-12 2.72E-09
WVDP-606 Rev. 1 Page 48 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1847 VEC 144' E Wall 7.27E-04 2.67E-04 3.59E-08 9.02E-07 2.14E-08 3.82E-05 1.16E-05 8.73E-06 6.58E-06 1.15E-04 7.63E-06 5.99E-07 2.79E-07 1.30E-08 1.88E-07 6.98E-10 3.33E-07 1853 VEC 144' E Wall 4.52E-03 1.66E-03 2.23E-07 5.61E-06 1.33E-07 2.37E-04 7.23E-05 5.43E-05 4.09E-05 7.14E-04 4.75E-05 3.73E-06 1.74E-06 8.09E-08 1.17E-06 4.34E-09 2.07E-06 1859 VEC 144' E Wall 1.89E-02 6.95E-03 9.36E-07 2.35E-05 5.57E-07 9.95E-04 3.03E-04 2.27E-04 1.71E-04 2.99E-03 1.99E-04 1.56E-05 7.28E-06 3.39E-07 4.89E-06 1.82E-08 8.68E-06 1844 VEC 144' Floor 4.69E-03 1.72E-03 2.32E-07 5.81E-06 1.38E-07 2.46E-04 7.50E-05 5.63E-05 4.24E-05 7.41E-04 4.92E-05 3.86E-06 1.80E-06 8.39E-08 1.21E-06 4.50E-09 2.15E-06 1850 VEC 144' Floor 5.11E-03 1.87E-03 2.52E-07 6.33E-06 1.50E-07 2.68E-04 8.17E-05 6.13E-05 4.62E-05 8.07E-04 5.36E-05 4.21E-06 1.96E-06 9.14E-08 1.32E-06 4.90E-09 2.34E-06 1856 VEC 144' Floor 7.75E-03 2.85E-03 3.83E-07 9.62E-06 2.28E-07 4.07E-04 1.24E-04 9.31E-05 7.02E-05 1.23E-03 8.14E-05 6.39E-06 2.98E-06 1.39E-07 2.00E-06 7.44E-09 3.55E-06 1862 VEC 144' Floor 1.48E-01 5.42E-02 7.30E-06 1.83E-04 4.34E-06 7.76E-03 2.36E-03 1.77E-03 1.34E-03 2.33E-02 1.55E-03 1.22E-04 5.67E-05 2.65E-06 3.81E-05 1.42E-07 6.77E-05 1839 VEC 144' N Wall 1.23E-04 4.51E-05 6.07E-09 1.52E-07 3.61E-09 6.45E-06 1.97E-06 1.47E-06 1.11E-06 1.94E-05 1.29E-06 1.01E-07 4.72E-08 2.20E-09 3.17E-08 1.18E-10 5.63E-08 1845 VEC 144' N Wall 9.80E-03 3.60E-03 4.84E-07 1.22E-05 2.88E-07 5.15E-04 1.57E-04 1.18E-04 8.87E-05 1.55E-03 1.03E-04 8.08E-06 3.76E-06 1.75E-07 2.53E-06 9.41E-09 4.49E-06 1851 VEC 144' N Wall 2.06E-03 7.57E-04 1.02E-07 2.56E-06 6.06E-08 1.08E-04 3.30E-05 2.48E-05 1.87E-05 3.26E-04 2.17E-05 1.70E-06 7.92E-07 3.69E-08 5.32E-07 1.98E-09 9.45E-07 1857 VEC 144' N Wall 4.29E-02 1.57E-02 2.12E-06 5.32E-05 1.26E-06 2.25E-03 6.86E-04 5.14E-04 3.88E-04 6.77E-03 4.50E-04 3.53E-05 1.65E-05 7.67E-07 1.11E-05 4.12E-08 1.96E-05 1840 VEC 144' S Wall 2.19E-03 8.05E-04 1.08E-07 2.72E-06 6.45E-08 1.15E-04 3.51E-05 2.63E-05 1.99E-05 3.47E-04 2.30E-05 1.81E-06 8.43E-07 3.93E-08 5.66E-07 2.11E-09 1.01E-06 1846 VEC 144' S Wall 1.57E-03 5.77E-04 7.77E-08 1.95E-06 4.62E-08 8.26E-05 2.52E-05 1.89E-05 1.42E-05 2.49E-04 1.65E-05 1.30E-06 6.04E-07 2.82E-08 4.06E-07 1.51E-09 7.20E-07 1852 VEC 144' S Wall 2.51E-03 9.21E-04 1.24E-07 3.11E-06 7.38E-08 1.32E-04 4.01E-05 3.01E-05 2.27E-05 3.96E-04 2.63E-05 2.07E-06 9.64E-07 4.49E-08 6.47E-07 2.41E-09 1.15E-06 1858 VEC 144' S. Wall 4.29E-02 1.57E-02 2.12E-06 5.32E-05 1.26E-06 2.25E-03 6.86E-04 5.14E-04 3.88E-04 6.77E-03 4.50E-04 3.53E-05 1.65E-05 7.67E-07 1.11E-05 4.12E-08 1.96E-05 1842 VEC 144' W Wall 2.37E-05 8.70E-06 1.17E-09 2.94E-08 6.97E-10 1.24E-06 3.79E-07 2.84E-07 2.14E-07 3.74E-06 2.49E-07 1.95E-08 9.10E-09 4.24E-10 6.11E-09 2.28E-11 1.09E-08 1848 VEC 144' W Wall 6.31E-03 2.31E-03 3.12E-07 7.82E-06 1.85E-07 3.31E-04 1.01E-04 7.57E-05 5.71E-05 9.96E-04 6.62E-05 5.20E-06 2.42E-06 1.13E-07 1.63E-06 6.05E-09 2.89E-06 1854 VEC 144' W Wall 3.56E-05 1.31E-05 1.76E-09 4.42E-08 1.05E-09 1.87E-06 5.70E-07 4.28E-07 3.22E-07 5.63E-06 3.74E-07 2.94E-08 1.37E-08 6.38E-10 9.19E-09 3.42E-11 1.63E-08 1860 VEC 144' W Wall 1.79E-02 6.58E-03 8.85E-07 2.22E-05 5.27E-07 9.41E-04 2.87E-04 2.15E-04 1.62E-04 2.83E-03 1.88E-04 1.48E-05 6.88E-06 3.21E-07 4.62E-06 1.72E-08 8.21E-06 2807 VEC 144' Pipe 15V1064 9.80E-04 3.60E-04 4.84E-08 1.22E-06 2.88E-08 5.15E-05 1.57E-05 1.18E-05 8.87E-06 1.55E-04 1.03E-05 8.08E-07 3.76E-07 1.75E-08 2.53E-07 9.41E-10 4.49E-07 1868 VOG Filter Room Ceiling 5.10E-06 1.36E-05 6.11E-10 1.36E-08 5.66E-11 6.93E-07 2.58E-07 1.91E-07 1.45E-07 2.21E-06 1.81E-08 7.08E-09 3.37E-09 2.37E-11 2.64E-10 4.89E-12 2.33E-09 1874 VOG Filter Room Ceiling 6.38E-07 1.70E-06 7.65E-11 1.70E-09 7.08E-12 8.67E-08 3.23E-08 2.39E-08 1.81E-08 2.77E-07 2.27E-09 8.86E-10 4.21E-10 2.96E-12 3.31E-11 6.12E-13 2.92E-10 1880 VOG Filter Room Ceiling 2.51E-06 6.69E-06 3.01E-10 6.67E-09 2.78E-11 3.41E-07 1.27E-07 9.40E-08 7.12E-08 1.09E-06 8.92E-09 3.48E-09 1.66E-09 1.17E-11 1.30E-10 2.41E-12 1.15E-09 1866 VOG Filter Room E Wall 8.31E-06 2.22E-05 9.97E-10 2.21E-08 9.22E-11 1.13E-06 4.21E-07 3.12E-07 2.36E-07 3.61E-06 2.96E-08 1.16E-08 5.49E-09 3.86E-11 4.31E-10 7.98E-12 3.81E-09 1872 VOG Filter Room E Wall 1.92E-06 5.12E-06 2.30E-10 5.10E-09 2.13E-11 2.61E-07 9.71E-08 7.19E-08 5.45E-08 8.33E-07 6.83E-09 2.67E-09 1.27E-09 8.92E-12 9.96E-11 1.84E-12 8.79E-10 1878 VOG Filter Room E Wall 2.64E-06 7.05E-06 3.17E-10 7.02E-09 2.93E-11 3.59E-07 1.34E-07 9.90E-08 7.50E-08 1.15E-06 9.40E-09 3.67E-09 1.75E-09 1.23E-11 1.37E-10 2.53E-12 1.21E-09 1869 VOG Filter Room Floor 3.57E-05 9.53E-05 4.28E-09 9.49E-08 3.96E-10 4.85E-06 1.81E-06 1.34E-06 1.01E-06 1.55E-05 1.27E-07 4.96E-08 2.36E-08 1.66E-10 1.85E-09 3.43E-11 1.63E-08 1875 VOG Filter Room Floor 5.10E-05 1.36E-04 6.11E-09 1.36E-07 5.66E-10 6.93E-06 2.58E-06 1.91E-06 1.45E-06 2.21E-05 1.81E-07 7.08E-08 3.37E-08 2.37E-10 2.64E-09 4.89E-11 2.33E-08 1881 VOG Filter Room Floor 2.83E-06 7.57E-06 3.40E-10 7.54E-09 3.15E-11 3.85E-07 1.43E-07 1.06E-07 8.05E-08 1.23E-06 1.01E-08 3.94E-09 1.87E-09 1.32E-11 1.47E-10 2.72E-12 1.30E-09 1864 VOG Filter Room N Wall 7.03E-05 1.88E-04 8.44E-09 1.87E-07 7.80E-10 9.56E-06 3.56E-06 2.64E-06 2.00E-06 3.05E-05 2.50E-07 9.77E-08 4.65E-08 3.27E-10 3.65E-09 6.75E-11 3.22E-08 1870 VOG Filter Room N Wall 7.66E-05 2.04E-04 9.19E-09 2.04E-07 8.50E-10 1.04E-05 3.87E-06 2.87E-06 2.17E-06 3.32E-05 2.73E-07 1.06E-07 5.06E-08 3.56E-10 3.97E-09 7.35E-11 3.51E-08 1876 VOG Filter Room N Wall 1.89E-06 5.04E-06 2.27E-10 5.02E-09 2.10E-11 2.57E-07 9.55E-08 7.08E-08 5.36E-08 8.20E-07 6.72E-09 2.62E-09 1.25E-09 8.78E-12 9.80E-11 1.81E-12 8.65E-10 1865 VOG Filter Room S Wall 1.55E-06 4.14E-06 1.86E-10 4.12E-09 1.72E-11 2.11E-07 7.85E-08 5.81E-08 4.40E-08 6.73E-07 5.52E-09 2.16E-09 1.02E-09 7.21E-12 8.05E-11 1.49E-12 7.10E-10 1871 VOG Filter Room S Wall 1.53E-05 4.09E-05 1.84E-09 4.07E-08 1.70E-10 2.08E-06 7.75E-07 5.74E-07 4.35E-07 6.65E-06 5.45E-08 2.13E-08 1.01E-08 7.12E-11 7.95E-10 1.47E-11 7.01E-09 1877 VOG Filter Room S Wall 2.14E-06 5.73E-06 2.57E-10 5.70E-09 2.38E-11 2.92E-07 1.09E-07 8.04E-08 6.09E-08 9.31E-07 7.63E-09 2.98E-09 1.42E-09 9.97E-12 1.11E-10 2.06E-12 9.82E-10
WVDP-606 Rev. 1 Page 49 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1867 VOG Filter Room W Wall 3.84E-06 1.03E-05 4.61E-10 1.02E-08 4.26E-11 5.23E-07 1.94E-07 1.44E-07 1.09E-07 1.67E-06 1.37E-08 5.34E-09 2.54E-09 1.79E-11 1.99E-10 3.69E-12 1.76E-09 1873 VOG Filter Room W Wall 6.38E-07 1.70E-06 7.65E-11 1.70E-09 7.08E-12 8.67E-08 3.23E-08 2.39E-08 1.81E-08 2.77E-07 2.27E-09 8.86E-10 4.21E-10 2.96E-12 3.31E-11 6.12E-13 2.92E-10 1879 VOG Filter Room W Wall 3.84E-06 1.03E-05 4.61E-10 1.02E-08 4.26E-11 5.23E-07 1.94E-07 1.44E-07 1.09E-07 1.67E-06 1.37E-08 5.34E-09 2.54E-09 1.79E-11 1.99E-10 3.69E-12 1.76E-09 1037 VSR 114' Ceiling 1.07E-03 3.92E-04 5.28E-08 1.32E-06 3.14E-08 5.61E-05 1.71E-05 1.28E-05 9.67E-06 1.69E-04 1.12E-05 8.80E-07 4.10E-07 1.91E-08 2.76E-07 1.03E-09 4.89E-07 1035 VSR 114' E Wall 3.50E-04 1.28E-04 1.73E-08 4.34E-07 1.03E-08 1.84E-05 5.59E-06 4.20E-06 3.16E-06 5.52E-05 3.67E-06 2.88E-07 1.34E-07 6.26E-09 9.02E-08 3.36E-10 1.60E-07 1038 VSR 114' Floor 6.23E-05 2.28E-05 3.08E-09 7.72E-08 1.83E-09 3.27E-06 9.96E-07 7.47E-07 5.63E-07 9.84E-06 6.54E-07 5.13E-08 2.39E-08 1.11E-09 1.61E-08 5.98E-11 2.85E-08 1033 VSR 114' N Wall 5.23E-06 1.92E-06 2.58E-10 6.49E-09 1.54E-10 2.75E-07 8.37E-08 6.28E-08 4.73E-08 8.26E-07 5.49E-08 4.31E-09 2.01E-09 9.36E-11 1.35E-09 5.02E-12 2.40E-09 1034 VSR 114' S Wall 1.81E-04 6.66E-05 8.96E-09 2.25E-07 5.33E-09 9.52E-06 2.90E-06 2.18E-06 1.64E-06 2.87E-05 1.90E-06 1.49E-07 6.97E-08 3.25E-09 4.68E-08 1.74E-10 8.31E-08 1036 VSR 114' W Wall 3.56E-06 1.30E-06 1.76E-10 4.41E-09 1.05E-10 1.87E-07 5.69E-08 4.27E-08 3.22E-08 5.62E-07 3.73E-08 2.93E-09 1.37E-09 6.36E-11 9.17E-10 3.41E-12 1.63E-09 1200 VWR Ceiling 1.05E-02 1.10E-02 8.15E-08 3.25E-05 1.78E-04 2.50E-03 8.08E-04 5.15E-04 3.57E-04 7.47E-03 2.59E-05 8.83E-06 3.14E-06 2.12E-07 2.10E-07 1.01E-08 4.83E-06 1206 VWR Ceiling 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1204 VWR E Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1198 VWR East Wall 3.75E-03 3.89E-03 2.89E-08 1.15E-05 6.33E-05 8.88E-04 2.87E-04 1.83E-04 1.27E-04 2.66E-03 9.21E-06 3.14E-06 1.12E-06 7.53E-08 7.45E-08 3.60E-09 1.72E-06 1201 VWR Floor 1.85E-02 1.92E-02 1.43E-07 5.69E-05 3.12E-04 4.38E-03 1.42E-03 9.04E-04 6.26E-04 1.31E-02 4.55E-05 1.55E-05 5.51E-06 3.71E-07 3.68E-07 1.77E-08 8.46E-06 1207 VWR Floor 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1202 VWR N Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1196 VWR North Wall 6.47E-03 6.73E-03 5.00E-08 1.99E-05 1.09E-04 1.53E-03 4.96E-04 3.16E-04 2.19E-04 4.59E-03 1.59E-05 5.42E-06 1.93E-06 1.30E-07 1.29E-07 6.21E-09 2.96E-06 1203 VWR S Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1629 VWR Sludge 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1197 VWR South Wall 1.50E-05 1.55E-05 1.16E-10 4.60E-08 2.53E-07 3.54E-06 1.15E-06 7.31E-07 5.07E-07 1.06E-05 3.68E-08 1.25E-08 4.46E-09 3.01E-10 2.98E-10 1.44E-11 6.85E-09 1205 VWR W Wall 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1199 VWR West Wall 2.07E-02 2.16E-02 1.60E-07 6.39E-05 3.50E-04 4.91E-03 1.59E-03 1.01E-03 7.03E-04 1.47E-02 5.10E-05 1.74E-05 6.18E-06 4.17E-07 4.13E-07 1.99E-08 9.50E-06 508 XC-1 Ceiling 7.21E-05 7.29E-05 3.17E-09 7.86E-08 4.86E-09 1.46E-05 3.22E-06 4.22E-06 3.22E-06 3.15E-05 4.52E-09 5.63E-09 2.73E-09 1.72E-09 5.89E-09 6.93E-11 3.30E-08 499 XC-1 E Wall Lower 2.38E-03 2.40E-03 1.05E-07 2.59E-06 1.60E-07 4.80E-04 1.06E-04 1.39E-04 1.06E-04 1.04E-03 1.49E-07 1.85E-07 8.99E-08 5.68E-08 1.94E-07 2.28E-09 1.09E-06 503 XC-1 E Wall Upper 4.87E-04 4.92E-04 2.14E-08 5.31E-07 3.28E-08 9.84E-05 2.18E-05 2.85E-05 2.18E-05 2.12E-04 3.05E-08 3.80E-08 1.84E-08 1.16E-08 3.98E-08 4.68E-10 2.23E-07 511 XC-1 N Wall Lower 2.94E-03 2.96E-03 1.29E-07 3.20E-06 1.98E-07 5.93E-04 1.31E-04 1.72E-04 1.31E-04 1.28E-03 1.84E-07 2.29E-07 1.11E-07 7.02E-08 2.40E-07 2.82E-09 1.34E-06 502 XC-1 N Wall Upper 2.55E-03 2.57E-03 1.12E-07 2.78E-06 1.72E-07 5.15E-04 1.14E-04 1.49E-04 1.14E-04 1.11E-03 1.60E-07 1.99E-07 9.63E-08 6.09E-08 2.08E-07 2.45E-09 1.17E-06 506 XC-1 S Wall Lower 6.92E-03 6.98E-03 3.04E-07 7.54E-06 4.66E-07 1.40E-03 3.09E-04 4.05E-04 3.09E-04 3.02E-03 4.34E-07 5.39E-07 2.61E-07 1.65E-07 5.65E-07 6.64E-09 3.17E-06 498 XC-1 S Wall Upper 2.55E-03 2.57E-03 1.12E-07 2.78E-06 1.72E-07 5.15E-04 1.14E-04 1.49E-04 1.14E-04 1.11E-03 1.60E-07 1.99E-07 9.63E-08 6.09E-08 2.08E-07 2.45E-09 1.17E-06 507 XC-1 W Wall Lower 8.21E-03 8.29E-03 3.61E-07 8.95E-06 5.53E-07 1.66E-03 3.67E-04 4.80E-04 3.67E-04 3.58E-03 5.15E-07 6.40E-07 3.10E-07 1.96E-07 6.71E-07 7.88E-09 3.76E-06 504 XC-1 W Wall Upper 8.06E-04 8.14E-04 3.55E-08 8.79E-07 5.43E-08 1.63E-04 3.60E-05 4.71E-05 3.60E-05 3.51E-04 5.05E-08 6.29E-08 3.05E-08 1.93E-08 6.58E-08 7.74E-10 3.69E-07 521 XC-2 Ceiling 8.01E-05 1.33E-04 4.88E-09 1.05E-07 1.14E-09 2.89E-04 9.85E-05 6.44E-05 4.91E-05 8.65E-04 4.60E-08 5.04E-07 2.44E-07 3.69E-07 9.61E-08 7.69E-11 3.67E-08 520 XC-2 E Wall 3.39E-05 5.62E-05 2.07E-09 4.44E-08 4.81E-10 1.22E-04 4.17E-05 2.72E-05 2.08E-05 3.66E-04 1.94E-08 2.13E-07 1.03E-07 1.56E-07 4.06E-08 3.25E-11 1.55E-08 518 XC-2 N Wall 8.83E-05 1.47E-04 5.39E-09 1.16E-07 1.25E-09 3.19E-04 1.09E-04 7.10E-05 5.42E-05 9.54E-04 5.07E-08 5.57E-07 2.69E-07 4.07E-07 1.06E-07 8.48E-11 4.05E-08 519 XC-2 S Wall 9.25E-05 1.54E-04 5.64E-09 1.21E-07 1.31E-09 3.34E-04 1.14E-04 7.44E-05 5.67E-05 9.99E-04 5.31E-08 5.83E-07 2.82E-07 4.26E-07 1.11E-07 8.88E-11 4.24E-08
WVDP-606 Rev. 1 Page 50 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 517 XC-2 W Wall 2.18E-04 3.61E-04 1.33E-08 2.85E-07 3.09E-09 7.86E-04 2.68E-04 1.75E-04 1.33E-04 2.35E-03 1.25E-07 1.37E-06 6.64E-07 1.00E-06 2.61E-07 2.09E-10 9.97E-08 1222 XC-2 Pipe 13P128 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 2104 XC-2 Pipe 13P128 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 1226 XC-2 Pipe 13P191 2.47E-08 4.10E-08 1.51E-12 3.24E-11 3.51E-13 8.92E-08 3.04E-08 1.99E-08 1.51E-08 2.67E-07 1.42E-11 1.56E-10 7.53E-11 1.14E-10 2.96E-11 2.37E-14 1.13E-11 1227 XC-2 Pipe 13P191 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 2108 XC-2 Pipe 13P191 2.47E-08 4.10E-08 1.51E-12 3.24E-11 3.51E-13 8.92E-08 3.04E-08 1.99E-08 1.51E-08 2.67E-07 1.42E-11 1.56E-10 7.53E-11 1.14E-10 2.96E-11 2.37E-14 1.13E-11 2109 XC-2 Pipe 13P191 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 1228 XC-2 Pipe 13P192 4.92E-08 8.18E-08 3.00E-12 6.45E-11 6.99E-13 1.78E-07 6.06E-08 3.96E-08 3.02E-08 5.32E-07 2.83E-11 3.10E-10 1.50E-10 2.27E-10 5.91E-11 4.73E-14 2.26E-11 2110 XC-2 Pipe 13P192 4.92E-08 8.18E-08 3.00E-12 6.45E-11 6.99E-13 1.78E-07 6.06E-08 3.96E-08 3.02E-08 5.32E-07 2.83E-11 3.10E-10 1.50E-10 2.27E-10 5.91E-11 4.73E-14 2.26E-11 1229 XC-2 Pipe 13P205 1.48E-07 2.46E-07 9.04E-12 1.94E-10 2.10E-12 5.35E-07 1.82E-07 1.19E-07 9.08E-08 1.60E-06 8.50E-11 9.33E-10 4.52E-10 6.83E-10 1.78E-10 1.42E-13 6.78E-11 1230 XC-2 Pipe 13P205 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 2111 XC-2 Pipe 13P205 1.48E-07 2.46E-07 9.04E-12 1.94E-10 2.10E-12 5.35E-07 1.82E-07 1.19E-07 9.08E-08 1.60E-06 8.50E-11 9.33E-10 4.52E-10 6.83E-10 1.78E-10 1.42E-13 6.78E-11 2112 XC-2 Pipe 13P205 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 1231 XC-2 Pipe 13P207 1.03E-06 1.71E-06 6.28E-11 1.35E-09 1.46E-11 3.72E-06 1.27E-06 8.28E-07 6.31E-07 1.11E-05 5.91E-10 6.49E-09 3.14E-09 4.75E-09 1.24E-09 9.89E-13 4.72E-10 2113 XC-2 Pipe 13P207 1.03E-06 1.71E-06 6.28E-11 1.35E-09 1.46E-11 3.72E-06 1.27E-06 8.28E-07 6.31E-07 1.11E-05 5.91E-10 6.49E-09 3.14E-09 4.75E-09 1.24E-09 9.89E-13 4.72E-10 1232 XC-2 Pipe 13P209 9.06E-08 1.50E-07 5.53E-12 1.19E-10 1.29E-12 3.27E-07 1.11E-07 7.28E-08 5.55E-08 9.78E-07 5.20E-11 5.71E-10 2.76E-10 4.18E-10 1.09E-10 8.70E-14 4.15E-11 2114 XC-2 Pipe 13P209 9.06E-08 1.50E-07 5.53E-12 1.19E-10 1.29E-12 3.27E-07 1.11E-07 7.28E-08 5.55E-08 9.78E-07 5.20E-11 5.71E-10 2.76E-10 4.18E-10 1.09E-10 8.70E-14 4.15E-11 1233 XC-2 Pipe 13P211 8.27E-07 1.37E-06 5.05E-11 1.08E-09 1.17E-11 2.99E-06 1.02E-06 6.65E-07 5.07E-07 8.93E-06 4.75E-10 5.21E-09 2.52E-09 3.81E-09 9.92E-10 7.94E-13 3.79E-10 2115 XC-2 Pipe 13P211 8.27E-07 1.37E-06 5.05E-11 1.08E-09 1.17E-11 2.99E-06 1.02E-06 6.65E-07 5.07E-07 8.93E-06 4.75E-10 5.21E-09 2.52E-09 3.81E-09 9.92E-10 7.94E-13 3.79E-10 1234 XC-2 Pipe 13P213 1.03E-06 1.71E-06 6.28E-11 1.35E-09 1.46E-11 3.72E-06 1.27E-06 8.28E-07 6.31E-07 1.11E-05 5.91E-10 6.49E-09 3.14E-09 4.75E-09 1.24E-09 9.89E-13 4.72E-10 2116 XC-2 Pipe 13P213 1.03E-06 1.71E-06 6.28E-11 1.35E-09 1.46E-11 3.72E-06 1.27E-06 8.28E-07 6.31E-07 1.11E-05 5.91E-10 6.49E-09 3.14E-09 4.75E-09 1.24E-09 9.89E-13 4.72E-10 1235 XC-2 Pipe 13P226 3.71E-07 6.15E-07 2.26E-11 4.86E-10 5.26E-12 1.34E-06 4.56E-07 2.98E-07 2.27E-07 4.00E-06 2.13E-10 2.34E-09 1.13E-09 1.71E-09 4.45E-10 3.56E-13 1.70E-10 2117 XC-2 Pipe 13P226 3.71E-07 6.15E-07 2.26E-11 4.86E-10 5.26E-12 1.34E-06 4.56E-07 2.98E-07 2.27E-07 4.00E-06 2.13E-10 2.34E-09 1.13E-09 1.71E-09 4.45E-10 3.56E-13 1.70E-10 1236 XC-2 Pipe 13P231 4.81E-07 7.99E-07 2.94E-11 6.30E-10 6.83E-12 1.74E-06 5.92E-07 3.87E-07 2.95E-07 5.20E-06 2.76E-10 3.03E-09 1.47E-09 2.22E-09 5.77E-10 4.62E-13 2.20E-10 2118 XC-2 Pipe 13P231 4.81E-07 7.99E-07 2.94E-11 6.30E-10 6.83E-12 1.74E-06 5.92E-07 3.87E-07 2.95E-07 5.20E-06 2.76E-10 3.03E-09 1.47E-09 2.22E-09 5.77E-10 4.62E-13 2.20E-10 1237 XC-2 Pipe 13P233 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 2119 XC-2 Pipe 13P233 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 1239 XC-2 Pipe 13P246 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 2121 XC-2 Pipe 13P246 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 1240 XC-2 Pipe 13P247 9.29E-09 1.54E-08 5.66E-13 1.22E-11 1.32E-13 3.35E-08 1.14E-08 7.47E-09 5.69E-09 1.00E-07 5.33E-12 5.85E-11 2.83E-11 4.28E-11 1.11E-11 8.91E-15 4.25E-12 1241 XC-2 Pipe 13P247 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 2122 XC-2 Pipe 13P247 9.29E-09 1.54E-08 5.66E-13 1.22E-11 1.32E-13 3.35E-08 1.14E-08 7.47E-09 5.69E-09 1.00E-07 5.33E-12 5.85E-11 2.83E-11 4.28E-11 1.11E-11 8.91E-15 4.25E-12 2123 XC-2 Pipe 13P247 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 1243 XC-2 Pipe 13P26 1.24E-04 2.05E-04 7.54E-09 1.62E-07 1.76E-09 4.47E-04 1.52E-04 9.94E-05 7.58E-05 1.34E-03 7.10E-08 7.79E-07 3.77E-07 5.70E-07 1.48E-07 1.19E-10 5.66E-08 2125 XC-2 Pipe 13P26 1.24E-04 2.05E-04 7.54E-09 1.62E-07 1.76E-09 4.47E-04 1.52E-04 9.94E-05 7.58E-05 1.34E-03 7.10E-08 7.79E-07 3.77E-07 5.70E-07 1.48E-07 1.19E-10 5.66E-08
WVDP-606 Rev. 1 Page 51 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1244 XC-2 Pipe 13P38 4.62E-08 7.68E-08 2.82E-12 6.06E-11 6.57E-13 1.67E-07 5.69E-08 3.72E-08 2.83E-08 4.99E-07 2.65E-11 2.91E-10 1.41E-10 2.13E-10 5.55E-11 4.44E-14 2.12E-11 2126 XC-2 Pipe 13P38 4.62E-08 7.68E-08 2.82E-12 6.06E-11 6.57E-13 1.67E-07 5.69E-08 3.72E-08 2.83E-08 4.99E-07 2.65E-11 2.91E-10 1.41E-10 2.13E-10 5.55E-11 4.44E-14 2.12E-11 1246 XC-2 Pipe 13P40 3.29E-08 5.47E-08 2.01E-12 4.31E-11 4.68E-13 1.19E-07 4.05E-08 2.65E-08 2.02E-08 3.56E-07 1.89E-11 2.07E-10 1.00E-10 1.52E-10 3.95E-11 3.16E-14 1.51E-11 2128 XC-2 Pipe 13P40 3.29E-08 5.47E-08 2.01E-12 4.31E-11 4.68E-13 1.19E-07 4.05E-08 2.65E-08 2.02E-08 3.56E-07 1.89E-11 2.07E-10 1.00E-10 1.52E-10 3.95E-11 3.16E-14 1.51E-11 1250 XC-2 Pipe 13P55 1.24E-06 2.06E-06 7.57E-11 1.63E-09 1.76E-11 4.48E-06 1.53E-06 9.97E-07 7.60E-07 1.34E-05 7.12E-10 7.82E-09 3.78E-09 5.72E-09 1.49E-09 1.19E-12 5.68E-10 2132 XC-2 Pipe 13P55 1.24E-06 2.06E-06 7.57E-11 1.63E-09 1.76E-11 4.48E-06 1.53E-06 9.97E-07 7.60E-07 1.34E-05 7.12E-10 7.82E-09 3.78E-09 5.72E-09 1.49E-09 1.19E-12 5.68E-10 1252 XC-2 Pipe 13P77 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 2134 XC-2 Pipe 13P77 1.55E-08 2.56E-08 9.43E-13 2.02E-11 2.19E-13 5.58E-08 1.90E-08 1.24E-08 9.47E-09 1.67E-07 8.87E-12 9.73E-11 4.71E-11 7.12E-11 1.85E-11 1.48E-14 7.08E-12 1254 XC-2 Pipe 13P79 1.65E-07 2.73E-07 1.00E-11 2.16E-10 2.34E-12 5.94E-07 2.03E-07 1.32E-07 1.01E-07 1.78E-06 9.45E-11 1.04E-09 5.02E-10 7.59E-10 1.98E-10 1.58E-13 7.54E-11 2136 XC-2 Pipe 13P79 1.65E-07 2.73E-07 1.00E-11 2.16E-10 2.34E-12 5.94E-07 2.03E-07 1.32E-07 1.01E-07 1.78E-06 9.45E-11 1.04E-09 5.02E-10 7.59E-10 1.98E-10 1.58E-13 7.54E-11 1255 XC-2 Pipe 14CH194 4.14E-06 6.86E-06 2.52E-10 5.42E-09 5.87E-11 1.49E-05 5.09E-06 3.32E-06 2.53E-06 4.47E-05 2.37E-09 2.61E-08 1.26E-08 1.91E-08 4.96E-09 3.97E-12 1.89E-09 2137 XC-2 Pipe 14CH194 2.52E-06 4.19E-06 1.54E-10 3.30E-09 3.58E-11 9.11E-06 3.10E-06 2.03E-06 1.55E-06 2.72E-05 1.45E-09 1.59E-08 7.69E-09 1.16E-08 3.03E-09 2.42E-12 1.16E-09 1256 XC-2 Pipe 14CH235 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2138 XC-2 Pipe 14CH235 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 1257 XC-2 Pipe 14CH253 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2139 XC-2 Pipe 14CH253 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 1258 XC-2 Pipe 14CH294 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2140 XC-2 Pipe 14CH294 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1259 XC-2 Pipe 14CH327 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2141 XC-2 Pipe 14CH327 2.12E-09 3.51E-09 1.29E-13 2.77E-12 3.01E-14 7.64E-09 2.60E-09 1.70E-09 1.30E-09 2.29E-08 1.21E-12 1.33E-11 6.46E-12 9.76E-12 2.54E-12 2.03E-15 9.69E-13 1260 XC-2 Pipe 14CH330 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2142 XC-2 Pipe 14CH330 2.12E-09 3.51E-09 1.29E-13 2.77E-12 3.01E-14 7.64E-09 2.60E-09 1.70E-09 1.30E-09 2.29E-08 1.21E-12 1.33E-11 6.46E-12 9.76E-12 2.54E-12 2.03E-15 9.69E-13 1261 XC-2 Pipe 14P1446 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 2143 XC-2 Pipe 14P1446 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 1263 XC-2 Pipe 15CH761 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 2145 XC-2 Pipe 15CH761 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 1264 XC-2 Pipe 15CH767 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 2146 XC-2 Pipe 15CH767 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 1274 XC-2 Pipe 15P1366 1.65E-07 2.73E-07 1.00E-11 2.16E-10 2.34E-12 5.94E-07 2.03E-07 1.32E-07 1.01E-07 1.78E-06 9.45E-11 1.04E-09 5.02E-10 7.59E-10 1.98E-10 1.58E-13 7.54E-11 2156 XC-2 Pipe 15P1366 1.65E-07 2.73E-07 1.00E-11 2.16E-10 2.34E-12 5.94E-07 2.03E-07 1.32E-07 1.01E-07 1.78E-06 9.45E-11 1.04E-09 5.02E-10 7.59E-10 1.98E-10 1.58E-13 7.54E-11 1276 XC-2 Pipe 15P1377 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 2158 XC-2 Pipe 15P1377 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1277 XC-2 Pipe 15P1378 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 2159 XC-2 Pipe 15P1378 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 1278 XC-2 Pipe 15P1379 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12
WVDP-606 Rev. 1 Page 52 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2160 XC-2 Pipe 15P1379 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1279 XC-2 Pipe 15P1380 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 2161 XC-2 Pipe 15P1380 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1282 XC-2 Pipe 15P1438 2.07E-08 3.44E-08 1.26E-12 2.71E-11 2.94E-13 7.48E-08 2.55E-08 1.67E-08 1.27E-08 2.24E-07 1.19E-11 1.31E-10 6.32E-11 9.55E-11 2.49E-11 1.99E-14 9.49E-12 2164 XC-2 Pipe 15P1438 2.07E-08 3.44E-08 1.26E-12 2.71E-11 2.94E-13 7.48E-08 2.55E-08 1.67E-08 1.27E-08 2.24E-07 1.19E-11 1.31E-10 6.32E-11 9.55E-11 2.49E-11 1.99E-14 9.49E-12 1283 XC-2 Pipe 15P1439 8.23E-07 1.37E-06 5.02E-11 1.08E-09 1.17E-11 2.97E-06 1.01E-06 6.62E-07 5.05E-07 8.89E-06 4.73E-10 5.19E-09 2.51E-09 3.80E-09 9.88E-10 7.90E-13 3.77E-10 2165 XC-2 Pipe 15P1439 8.23E-07 1.37E-06 5.02E-11 1.08E-09 1.17E-11 2.97E-06 1.01E-06 6.62E-07 5.05E-07 8.89E-06 4.73E-10 5.19E-09 2.51E-09 3.80E-09 9.88E-10 7.90E-13 3.77E-10 1284 XC-2 Pipe 15P1440 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 2166 XC-2 Pipe 15P1440 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 1285 XC-2 Pipe 15P1441 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 2167 XC-2 Pipe 15P1441 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 1286 XC-2 Pipe 15P1442 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 2168 XC-2 Pipe 15P1442 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1287 XC-2 Pipe 15P1443 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 2169 XC-2 Pipe 15P1443 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 1288 XC-2 Pipe 15P1444 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 2170 XC-2 Pipe 15P1444 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 1289 XC-2 Pipe 15P1445 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 2171 XC-2 Pipe 15P1445 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1290 XC-2 Pipe 15P1447 2.07E-08 3.44E-08 1.26E-12 2.71E-11 2.94E-13 7.48E-08 2.55E-08 1.67E-08 1.27E-08 2.24E-07 1.19E-11 1.31E-10 6.32E-11 9.55E-11 2.49E-11 1.99E-14 9.49E-12 2172 XC-2 Pipe 15P1447 2.07E-08 3.44E-08 1.26E-12 2.71E-11 2.94E-13 7.48E-08 2.55E-08 1.67E-08 1.27E-08 2.24E-07 1.19E-11 1.31E-10 6.32E-11 9.55E-11 2.49E-11 1.99E-14 9.49E-12 1291 XC-2 Pipe 15P1448 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 2173 XC-2 Pipe 15P1448 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 1292 XC-2 Pipe 15P1449 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 2174 XC-2 Pipe 15P1449 2.76E-08 4.58E-08 1.68E-12 3.61E-11 3.92E-13 9.96E-08 3.39E-08 2.22E-08 1.69E-08 2.98E-07 1.58E-11 1.74E-10 8.42E-11 1.27E-10 3.31E-11 2.65E-14 1.26E-11 1294 XC-2 Pipe 15V1084 1.48E-07 2.46E-07 9.04E-12 1.94E-10 2.10E-12 5.35E-07 1.82E-07 1.19E-07 9.08E-08 1.60E-06 8.50E-11 9.33E-10 4.52E-10 6.83E-10 1.78E-10 1.42E-13 6.78E-11 2176 XC-2 Pipe 15V1084 1.48E-07 2.46E-07 9.04E-12 1.94E-10 2.10E-12 5.35E-07 1.82E-07 1.19E-07 9.08E-08 1.60E-06 8.50E-11 9.33E-10 4.52E-10 6.83E-10 1.78E-10 1.42E-13 6.78E-11 1295 XC-2 Pipe 15V1085 8.27E-08 1.37E-07 5.05E-12 1.08E-10 1.17E-12 2.99E-07 1.02E-07 6.65E-08 5.07E-08 8.93E-07 4.75E-11 5.21E-10 2.52E-10 3.81E-10 9.92E-11 7.94E-14 3.79E-11 2177 XC-2 Pipe 15V1085 8.27E-08 1.37E-07 5.05E-12 1.08E-10 1.17E-12 2.99E-07 1.02E-07 6.65E-08 5.07E-08 8.93E-07 4.75E-11 5.21E-10 2.52E-10 3.81E-10 9.92E-11 7.94E-14 3.79E-11 1296 XC-2 Pipe 15V1086 1.24E-07 2.06E-07 7.57E-12 1.63E-10 1.76E-12 4.48E-07 1.53E-07 9.97E-08 7.60E-08 1.34E-06 7.12E-11 7.82E-10 3.78E-10 5.72E-10 1.49E-10 1.19E-13 5.68E-11 2178 XC-2 Pipe 15V1086 1.24E-07 2.06E-07 7.57E-12 1.63E-10 1.76E-12 4.48E-07 1.53E-07 9.97E-08 7.60E-08 1.34E-06 7.12E-11 7.82E-10 3.78E-10 5.72E-10 1.49E-10 1.19E-13 5.68E-11 1297 XC-2 Pipe 15V1090 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 2179 XC-2 Pipe 15V1090 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 1298 XC-2 Pipe 15V1091 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 2180 XC-2 Pipe 15V1091 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10
WVDP-606 Rev. 1 Page 53 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1299 XC-2 Pipe 15V1092 6.17E-09 1.02E-08 3.76E-13 8.08E-12 8.75E-14 2.23E-08 7.58E-09 4.96E-09 3.78E-09 6.66E-08 3.54E-12 3.88E-11 1.88E-11 2.84E-11 7.40E-12 5.92E-15 2.82E-12 2181 XC-2 Pipe 15V1092 6.17E-09 1.02E-08 3.76E-13 8.08E-12 8.75E-14 2.23E-08 7.58E-09 4.96E-09 3.78E-09 6.66E-08 3.54E-12 3.88E-11 1.88E-11 2.84E-11 7.40E-12 5.92E-15 2.82E-12 1300 XC-2 Pipe 15V1097 3.71E-08 6.15E-08 2.26E-12 4.86E-11 5.26E-13 1.34E-07 4.56E-08 2.98E-08 2.27E-08 4.00E-07 2.13E-11 2.34E-10 1.13E-10 1.71E-10 4.45E-11 3.56E-14 1.70E-11 2182 XC-2 Pipe 15V1097 3.71E-08 6.15E-08 2.26E-12 4.86E-11 5.26E-13 1.34E-07 4.56E-08 2.98E-08 2.27E-08 4.00E-07 2.13E-11 2.34E-10 1.13E-10 1.71E-10 4.45E-11 3.56E-14 1.70E-11 1301 XC-2 Pipe 15V956 1.58E-03 2.63E-03 9.65E-08 2.07E-06 2.25E-08 5.71E-03 1.95E-03 1.27E-03 9.70E-04 1.71E-02 9.08E-07 9.97E-06 4.83E-06 7.30E-06 1.90E-06 1.52E-09 7.25E-07 1317 XC-2 Pipe 4J358 5.15E-11 8.55E-11 3.14E-15 6.75E-14 7.31E-16 1.86E-10 6.33E-11 4.14E-11 3.16E-11 5.56E-10 2.96E-14 3.24E-13 1.57E-13 2.37E-13 6.18E-14 4.94E-17 2.36E-14 2199 XC-2 Pipe 4J358 3.53E-10 5.85E-10 2.15E-14 4.62E-13 5.01E-15 1.27E-09 4.34E-10 2.84E-10 2.16E-10 3.81E-09 2.02E-13 2.22E-12 1.08E-12 1.63E-12 4.23E-13 3.39E-16 1.62E-13 1318 XC-2 Pipe 4J359 5.15E-11 8.55E-11 3.14E-15 6.75E-14 7.31E-16 1.86E-10 6.33E-11 4.14E-11 3.16E-11 5.56E-10 2.96E-14 3.24E-13 1.57E-13 2.37E-13 6.18E-14 4.94E-17 2.36E-14 2200 XC-2 Pipe 4J359 3.53E-10 5.85E-10 2.15E-14 4.62E-13 5.01E-15 1.27E-09 4.34E-10 2.84E-10 2.16E-10 3.81E-09 2.02E-13 2.22E-12 1.08E-12 1.63E-12 4.23E-13 3.39E-16 1.62E-13 1319 XC-2 Pipe 4J384 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 2201 XC-2 Pipe 4J384 3.58E-10 5.95E-10 2.19E-14 4.69E-13 5.09E-15 1.29E-09 4.41E-10 2.88E-10 2.20E-10 3.87E-09 2.06E-13 2.26E-12 1.09E-12 1.65E-12 4.30E-13 3.44E-16 1.64E-13 1320 XC-2 Pipe 4J402A 1.03E-10 1.71E-10 6.28E-15 1.35E-13 1.46E-15 3.72E-10 1.27E-10 8.28E-11 6.31E-11 1.11E-09 5.91E-14 6.49E-13 3.14E-13 4.75E-13 1.24E-13 9.89E-17 4.72E-14 2202 XC-2 Pipe 4J402A 1.03E-10 1.71E-10 6.28E-15 1.35E-13 1.46E-15 3.72E-10 1.27E-10 8.28E-11 6.31E-11 1.11E-09 5.91E-14 6.49E-13 3.14E-13 4.75E-13 1.24E-13 9.89E-17 4.72E-14 1321 XC-2 Pipe 4J402B 1.03E-10 1.71E-10 6.28E-15 1.35E-13 1.46E-15 3.72E-10 1.27E-10 8.28E-11 6.31E-11 1.11E-09 5.91E-14 6.49E-13 3.14E-13 4.75E-13 1.24E-13 9.89E-17 4.72E-14 2203 XC-2 Pipe 4J402B 1.03E-10 1.71E-10 6.28E-15 1.35E-13 1.46E-15 3.72E-10 1.27E-10 8.28E-11 6.31E-11 1.11E-09 5.91E-14 6.49E-13 3.14E-13 4.75E-13 1.24E-13 9.89E-17 4.72E-14 1322 XC-2 Pipe 4P126 4.06E-08 6.74E-08 2.48E-12 5.32E-11 5.77E-13 1.47E-07 4.99E-08 3.26E-08 2.49E-08 4.38E-07 2.33E-11 2.56E-10 1.24E-10 1.87E-10 4.87E-11 3.90E-14 1.86E-11 2204 XC-2 Pipe 4P126 4.06E-08 6.74E-08 2.48E-12 5.32E-11 5.77E-13 1.47E-07 4.99E-08 3.26E-08 2.49E-08 4.38E-07 2.33E-11 2.56E-10 1.24E-10 1.87E-10 4.87E-11 3.90E-14 1.86E-11 1323 XC-2 Pipe 4P138 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 2205 XC-2 Pipe 4P138 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 1324 XC-2 Pipe 4P152 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 2206 XC-2 Pipe 4P152 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1325 XC-2 Pipe 4P158 2.06E-09 3.42E-09 1.26E-13 2.70E-12 2.93E-14 7.44E-09 2.53E-09 1.66E-09 1.26E-09 2.22E-08 1.18E-12 1.30E-11 6.28E-12 9.50E-12 2.47E-12 1.98E-15 9.44E-13 2207 XC-2 Pipe 4P158 2.06E-09 3.42E-09 1.26E-13 2.70E-12 2.93E-14 7.44E-09 2.53E-09 1.66E-09 1.26E-09 2.22E-08 1.18E-12 1.30E-11 6.28E-12 9.50E-12 2.47E-12 1.98E-15 9.44E-13 1327 XC-2 Pipe 4P180 3.26E-08 5.42E-08 1.99E-12 4.27E-11 4.63E-13 1.18E-07 4.01E-08 2.62E-08 2.00E-08 3.52E-07 1.87E-11 2.06E-10 9.95E-11 1.50E-10 3.92E-11 3.13E-14 1.49E-11 1328 XC-2 Pipe 4P180 5.45E-08 9.05E-08 3.33E-12 7.14E-11 7.74E-13 1.97E-07 6.70E-08 4.38E-08 3.34E-08 5.89E-07 3.13E-11 3.43E-10 1.66E-10 2.51E-10 6.54E-11 5.23E-14 2.50E-11 2209 XC-2 Pipe 4P180 5.45E-08 9.05E-08 3.33E-12 7.14E-11 7.74E-13 1.97E-07 6.70E-08 4.38E-08 3.34E-08 5.89E-07 3.13E-11 3.43E-10 1.66E-10 2.51E-10 6.54E-11 5.23E-14 2.50E-11 2210 XC-2 Pipe 4P180 3.26E-08 5.42E-08 1.99E-12 4.27E-11 4.63E-13 1.18E-07 4.01E-08 2.62E-08 2.00E-08 3.52E-07 1.87E-11 2.06E-10 9.95E-11 1.50E-10 3.92E-11 3.13E-14 1.49E-11 1329 XC-2 Pipe 4P208 9.29E-09 1.54E-08 5.66E-13 1.22E-11 1.32E-13 3.35E-08 1.14E-08 7.47E-09 5.69E-09 1.00E-07 5.33E-12 5.85E-11 2.83E-11 4.28E-11 1.11E-11 8.91E-15 4.25E-12 2211 XC-2 Pipe 4P208 9.29E-09 1.54E-08 5.66E-13 1.22E-11 1.32E-13 3.35E-08 1.14E-08 7.47E-09 5.69E-09 1.00E-07 5.33E-12 5.85E-11 2.83E-11 4.28E-11 1.11E-11 8.91E-15 4.25E-12 1330 XC-2 Pipe 4P224A 8.16E-08 1.35E-07 4.98E-12 1.07E-10 1.16E-12 2.95E-07 1.00E-07 6.56E-08 5.00E-08 8.81E-07 4.68E-11 5.14E-10 2.49E-10 3.76E-10 9.79E-11 7.83E-14 3.74E-11 2212 XC-2 Pipe 4P224A 8.16E-08 1.35E-07 4.98E-12 1.07E-10 1.16E-12 2.95E-07 1.00E-07 6.56E-08 5.00E-08 8.81E-07 4.68E-11 5.14E-10 2.49E-10 3.76E-10 9.79E-11 7.83E-14 3.74E-11 1331 XC-2 Pipe 4P224B 2.04E-08 3.38E-08 1.24E-12 2.67E-11 2.89E-13 7.36E-08 2.51E-08 1.64E-08 1.25E-08 2.20E-07 1.17E-11 1.28E-10 6.21E-11 9.39E-11 2.45E-11 1.96E-14 9.33E-12 2213 XC-2 Pipe 4P224B 2.04E-08 3.38E-08 1.24E-12 2.67E-11 2.89E-13 7.36E-08 2.51E-08 1.64E-08 1.25E-08 2.20E-07 1.17E-11 1.28E-10 6.21E-11 9.39E-11 2.45E-11 1.96E-14 9.33E-12 1332 XC-2 Pipe 4P227 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1333 XC-2 Pipe 4P227 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12
WVDP-606 Rev. 1 Page 54 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2214 XC-2 Pipe 4P227 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 2215 XC-2 Pipe 4P227 8.27E-09 1.37E-08 5.05E-13 1.08E-11 1.17E-13 2.99E-08 1.02E-08 6.65E-09 5.07E-09 8.93E-08 4.75E-12 5.21E-11 2.52E-11 3.81E-11 9.92E-12 7.94E-15 3.79E-12 1334 XC-2 Pipe 4P263 2.45E-08 4.06E-08 1.49E-12 3.21E-11 3.48E-13 8.84E-08 3.01E-08 1.97E-08 1.50E-08 2.64E-07 1.40E-11 1.54E-10 7.46E-11 1.13E-10 2.94E-11 2.35E-14 1.12E-11 2216 XC-2 Pipe 4P263 2.45E-08 4.06E-08 1.49E-12 3.21E-11 3.48E-13 8.84E-08 3.01E-08 1.97E-08 1.50E-08 2.64E-07 1.40E-11 1.54E-10 7.46E-11 1.13E-10 2.94E-11 2.35E-14 1.12E-11 1336 XC-2 Pipe 4P319 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 2218 XC-2 Pipe 4P319 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1337 XC-2 Pipe 4P32 2.76E-07 4.58E-07 1.68E-11 3.61E-10 3.92E-12 9.96E-07 3.39E-07 2.22E-07 1.69E-07 2.98E-06 1.58E-10 1.74E-09 8.42E-10 1.27E-09 3.31E-10 2.65E-13 1.26E-10 1338 XC-2 Pipe 4P331 3.09E-07 5.13E-07 1.89E-11 4.05E-10 4.39E-12 1.12E-06 3.80E-07 2.48E-07 1.89E-07 3.34E-06 1.77E-10 1.95E-09 9.43E-10 1.42E-09 3.71E-10 2.97E-13 1.42E-10 2220 XC-2 Pipe 4P331 3.09E-07 5.13E-07 1.89E-11 4.05E-10 4.39E-12 1.12E-06 3.80E-07 2.48E-07 1.89E-07 3.34E-06 1.77E-10 1.95E-09 9.43E-10 1.42E-09 3.71E-10 2.97E-13 1.42E-10 1339 XC-2 Pipe 4P332 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 2221 XC-2 Pipe 4P332 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 1340 XC-2 Pipe 4P348 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 2222 XC-2 Pipe 4P348 1.38E-08 2.29E-08 8.42E-13 1.81E-11 1.96E-13 4.98E-08 1.70E-08 1.11E-08 8.46E-09 1.49E-07 7.92E-12 8.69E-11 4.21E-11 6.36E-11 1.66E-11 1.32E-14 6.32E-12 1341 XC-2 Pipe 4P356 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 2223 XC-2 Pipe 4P356 4.14E-07 6.86E-07 2.52E-11 5.42E-10 5.87E-12 1.49E-06 5.09E-07 3.32E-07 2.53E-07 4.47E-06 2.37E-10 2.61E-09 1.26E-09 1.91E-09 4.96E-10 3.97E-13 1.89E-10 1342 XC-2 Pipe 4P357 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 2224 XC-2 Pipe 4P357 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1343 XC-2 Pipe 4P379 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2225 XC-2 Pipe 4P379 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 1344 XC-2 Pipe 4P380 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 2226 XC-2 Pipe 4P380 3.58E-10 5.95E-10 2.19E-14 4.69E-13 5.09E-15 1.29E-09 4.41E-10 2.88E-10 2.20E-10 3.87E-09 2.06E-13 2.26E-12 1.09E-12 1.65E-12 4.30E-13 3.44E-16 1.64E-13 1345 XC-2 Pipe 4P383 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 2227 XC-2 Pipe 4P383 3.09E-10 5.13E-10 1.89E-14 4.05E-13 4.39E-15 1.12E-09 3.80E-10 2.48E-10 1.89E-10 3.34E-09 1.77E-13 1.95E-12 9.43E-13 1.42E-12 3.71E-13 2.97E-16 1.42E-13 1346 XC-2 Pipe 4P385 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 2228 XC-2 Pipe 4P385 3.58E-10 5.95E-10 2.19E-14 4.69E-13 5.09E-15 1.29E-09 4.41E-10 2.88E-10 2.20E-10 3.87E-09 2.06E-13 2.26E-12 1.09E-12 1.65E-12 4.30E-13 3.44E-16 1.64E-13 1348 XC-2 Pipe 4P397 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 2230 XC-2 Pipe 4P397 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 1349 XC-2 Pipe 4P399A 1.24E-10 2.05E-10 7.54E-15 1.62E-13 1.76E-15 4.47E-10 1.52E-10 9.94E-11 7.58E-11 1.34E-09 7.10E-14 7.79E-13 3.77E-13 5.70E-13 1.48E-13 1.19E-16 5.66E-14 2231 XC-2 Pipe 4P399A 1.72E-09 2.85E-09 1.05E-13 2.25E-12 2.44E-14 6.20E-09 2.11E-09 1.38E-09 1.05E-09 1.86E-08 9.86E-13 1.08E-11 5.24E-12 7.92E-12 2.06E-12 1.65E-15 7.87E-13 1350 XC-2 Pipe 4P399C 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 2232 XC-2 Pipe 4P399C 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 1351 XC-2 Pipe 4P411 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2233 XC-2 Pipe 4P411 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1353 XC-2 Pipe 4P660 8.23E-11 1.37E-10 5.02E-15 1.08E-13 1.17E-15 2.97E-10 1.01E-10 6.62E-11 5.05E-11 8.89E-10 4.73E-14 5.19E-13 2.51E-13 3.80E-13 9.88E-14 7.90E-17 3.77E-14 2235 XC-2 Pipe 4P660 7.18E-10 1.19E-09 4.38E-14 9.41E-13 1.02E-14 2.59E-09 8.83E-10 5.77E-10 4.40E-10 7.75E-09 4.12E-13 4.52E-12 2.19E-12 3.31E-12 8.62E-13 6.89E-16 3.29E-13
WVDP-606 Rev. 1 Page 55 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1354 XC-2 Pipe 4P661 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2236 XC-2 Pipe 4P661 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1355 XC-2 Pipe 4P664 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 2237 XC-2 Pipe 4P664 4.62E-07 7.68E-07 2.82E-11 6.06E-10 6.57E-12 1.67E-06 5.69E-07 3.72E-07 2.83E-07 4.99E-06 2.65E-10 2.91E-09 1.41E-09 2.13E-09 5.55E-10 4.44E-13 2.12E-10 1358 XC-2 Pipe 4S192 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 2240 XC-2 Pipe 4S192 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 1359 XC-2 Pipe 4S351 1.55E-07 2.56E-07 9.43E-12 2.02E-10 2.19E-12 5.58E-07 1.90E-07 1.24E-07 9.47E-08 1.67E-06 8.87E-11 9.73E-10 4.71E-10 7.12E-10 1.85E-10 1.48E-13 7.08E-11 2241 XC-2 Pipe 4S351 1.55E-07 2.56E-07 9.43E-12 2.02E-10 2.19E-12 5.58E-07 1.90E-07 1.24E-07 9.47E-08 1.67E-06 8.87E-11 9.73E-10 4.71E-10 7.12E-10 1.85E-10 1.48E-13 7.08E-11 1360 XC-2 Pipe 4S363 2.06E-10 3.42E-10 1.26E-14 2.70E-13 2.93E-15 7.44E-10 2.53E-10 1.66E-10 1.26E-10 2.22E-09 1.18E-13 1.30E-12 6.28E-13 9.50E-13 2.47E-13 1.98E-16 9.44E-14 2242 XC-2 Pipe 4S363 2.06E-10 3.42E-10 1.26E-14 2.70E-13 2.93E-15 7.44E-10 2.53E-10 1.66E-10 1.26E-10 2.22E-09 1.18E-13 1.30E-12 6.28E-13 9.50E-13 2.47E-13 1.98E-16 9.44E-14 1362 XC-2 Pipe 4S443 4.14E-11 6.86E-11 2.52E-15 5.42E-14 5.87E-16 1.49E-10 5.09E-11 3.32E-11 2.53E-11 4.47E-10 2.37E-14 2.61E-13 1.26E-13 1.91E-13 4.96E-14 3.97E-17 1.89E-14 2244 XC-2 Pipe 4S443 2.92E-09 4.86E-09 1.78E-13 3.83E-12 4.15E-14 1.06E-08 3.60E-09 2.35E-09 1.79E-09 3.16E-08 1.68E-12 1.84E-11 8.92E-12 1.35E-11 3.51E-12 2.81E-15 1.34E-12 1363 XC-2 Pipe 5CH388 6.17E-07 1.02E-06 3.76E-11 8.08E-10 8.75E-12 2.23E-06 7.58E-07 4.96E-07 3.78E-07 6.66E-06 3.54E-10 3.88E-09 1.88E-09 2.84E-09 7.40E-10 5.92E-13 2.82E-10 2245 XC-2 Pipe 5CH388 6.17E-07 1.02E-06 3.76E-11 8.08E-10 8.75E-12 2.23E-06 7.58E-07 4.96E-07 3.78E-07 6.66E-06 3.54E-10 3.88E-09 1.88E-09 2.84E-09 7.40E-10 5.92E-13 2.82E-10 1364 XC-2 Pipe 5P199 6.62E-08 1.10E-07 4.04E-12 8.67E-11 9.40E-13 2.39E-07 8.14E-08 5.32E-08 4.06E-08 7.15E-07 3.80E-11 4.17E-10 2.02E-10 3.05E-10 7.94E-11 6.35E-14 3.03E-11 2246 XC-2 Pipe 5P199 6.62E-08 1.10E-07 4.04E-12 8.67E-11 9.40E-13 2.39E-07 8.14E-08 5.32E-08 4.06E-08 7.15E-07 3.80E-11 4.17E-10 2.02E-10 3.05E-10 7.94E-11 6.35E-14 3.03E-11 1365 XC-2 Pipe 5P260 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 2247 XC-2 Pipe 5P260 4.14E-08 6.86E-08 2.52E-12 5.42E-11 5.87E-13 1.49E-07 5.09E-08 3.32E-08 2.53E-08 4.47E-07 2.37E-11 2.61E-10 1.26E-10 1.91E-10 4.96E-11 3.97E-14 1.89E-11 1366 XC-2 Pipe 5P392 6.17E-09 1.02E-08 3.76E-13 8.08E-12 8.75E-14 2.23E-08 7.58E-09 4.96E-09 3.78E-09 6.66E-08 3.54E-12 3.88E-11 1.88E-11 2.84E-11 7.40E-12 5.92E-15 2.82E-12 2248 XC-2 Pipe 5P392 6.17E-09 1.02E-08 3.76E-13 8.08E-12 8.75E-14 2.23E-08 7.58E-09 4.96E-09 3.78E-09 6.66E-08 3.54E-12 3.88E-11 1.88E-11 2.84E-11 7.40E-12 5.92E-15 2.82E-12 1367 XC-2 Pipe 5P519 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 2249 XC-2 Pipe 5P519 1.24E-08 2.06E-08 7.57E-13 1.63E-11 1.76E-13 4.48E-08 1.53E-08 9.97E-09 7.60E-09 1.34E-07 7.12E-12 7.82E-11 3.78E-11 5.72E-11 1.49E-11 1.19E-14 5.68E-12 1369 XC-2 Pipe 6P100 1.93E-05 3.20E-05 1.18E-09 2.53E-08 2.74E-10 6.96E-05 2.37E-05 1.55E-05 1.18E-05 2.08E-04 1.11E-08 1.22E-07 5.88E-08 8.89E-08 2.31E-08 1.85E-11 8.83E-09 2251 XC-2 Pipe 6P100 1.93E-05 3.20E-05 1.18E-09 2.53E-08 2.74E-10 6.96E-05 2.37E-05 1.55E-05 1.18E-05 2.08E-04 1.11E-08 1.22E-07 5.88E-08 8.89E-08 2.31E-08 1.85E-11 8.83E-09 1370 XC-2 Pipe 7P16 3.09E-07 5.13E-07 1.89E-11 4.05E-10 4.39E-12 1.12E-06 3.80E-07 2.48E-07 1.89E-07 3.34E-06 1.77E-10 1.95E-09 9.43E-10 1.42E-09 3.71E-10 2.97E-13 1.42E-10 2252 XC-2 Pipe 7P16 3.09E-07 5.13E-07 1.89E-11 4.05E-10 4.39E-12 1.12E-06 3.80E-07 2.48E-07 1.89E-07 3.34E-06 1.77E-10 1.95E-09 9.43E-10 1.42E-09 3.71E-10 2.97E-13 1.42E-10 548 XC-3 Ceiling 9.34E-06 5.47E-05 1.30E-07 2.75E-06 1.20E-06 1.08E-02 3.43E-03 2.82E-03 2.16E-03 3.44E-02 6.48E-05 2.02E-05 9.81E-06 5.84E-07 7.47E-07 8.97E-12 4.28E-09 551 XC-3 E Wall 3.55E-05 2.08E-04 4.93E-07 1.04E-05 4.54E-06 4.12E-02 1.30E-02 1.07E-02 8.19E-03 1.31E-01 2.46E-04 7.66E-05 3.72E-05 2.22E-06 2.83E-06 3.41E-11 1.62E-08 547 XC-3 N Wall 1.86E-05 7.16E-06 2.50E-10 5.52E-09 1.61E-09 4.29E-04 1.73E-04 7.64E-05 5.83E-05 1.69E-03 1.18E-07 1.09E-06 5.28E-07 2.27E-08 3.49E-07 1.79E-11 8.54E-09 550 XC-3 S Wall 4.91E-05 1.89E-05 6.58E-10 1.45E-08 4.24E-09 1.13E-03 4.55E-04 2.01E-04 1.54E-04 4.47E-03 3.12E-07 2.87E-06 1.39E-06 5.99E-08 9.19E-07 4.72E-11 2.25E-08 549 XC-3 W Wall 1.26E-05 4.83E-06 1.68E-10 3.72E-09 1.08E-09 2.89E-04 1.17E-04 5.15E-05 3.94E-05 1.14E-03 7.97E-08 7.35E-07 3.56E-07 1.53E-08 2.35E-07 1.21E-11 5.76E-09 1958 XC-3 Pipe 13J116C 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 1959 XC-3 Pipe 13J122C 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 1960 XC-3 Pipe 13P117 2.97E-08 1.14E-08 3.98E-13 8.79E-12 2.56E-12 6.83E-07 2.75E-07 1.22E-07 9.30E-08 2.70E-06 1.88E-10 1.74E-09 8.40E-10 3.62E-11 5.55E-10 2.85E-14 1.36E-11 1961 XC-3 Pipe 13P120 1.58E-08 6.08E-09 2.12E-13 4.68E-12 1.36E-12 3.64E-07 1.47E-07 6.49E-08 4.95E-08 1.44E-06 1.00E-10 9.26E-10 4.48E-10 1.93E-11 2.96E-10 1.52E-14 7.25E-12
WVDP-606 Rev. 1 Page 56 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1962 XC-3 Pipe 13P191 7.95E-08 3.05E-08 1.07E-12 2.35E-11 6.85E-12 1.83E-06 7.37E-07 3.26E-07 2.49E-07 7.22E-06 5.04E-10 4.65E-09 2.25E-09 9.70E-11 1.49E-09 7.63E-14 3.64E-11 1963 XC-3 Pipe 13P192 1.58E-07 6.08E-08 2.12E-12 4.68E-11 1.36E-11 3.64E-06 1.47E-06 6.49E-07 4.95E-07 1.44E-05 1.00E-09 9.26E-09 4.48E-09 1.93E-10 2.96E-09 1.52E-13 7.25E-11 1964 XC-3 Pipe 13P222 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 1965 XC-3 Pipe 13S201 3.16E-07 1.22E-07 4.24E-12 9.37E-11 2.73E-11 7.28E-06 2.93E-06 1.30E-06 9.91E-07 2.88E-05 2.01E-09 1.85E-08 8.96E-09 3.86E-10 5.92E-09 3.04E-13 1.45E-10 1966 XC-3 Pipe 13S202 3.16E-07 1.22E-07 4.24E-12 9.37E-11 2.73E-11 7.28E-06 2.93E-06 1.30E-06 9.91E-07 2.88E-05 2.01E-09 1.85E-08 8.96E-09 3.86E-10 5.92E-09 3.04E-13 1.45E-10 1967 XC-3 Pipe 15CH636 1.58E-07 6.08E-08 2.12E-12 4.68E-11 1.36E-11 3.64E-06 1.47E-06 6.49E-07 4.95E-07 1.44E-05 1.00E-09 9.26E-09 4.48E-09 1.93E-10 2.96E-09 1.52E-13 7.25E-11 1968 XC-3 Pipe 15CH642 3.96E-08 1.52E-08 5.31E-13 1.17E-11 3.41E-12 9.11E-07 3.67E-07 1.62E-07 1.24E-07 3.60E-06 2.51E-10 2.32E-09 1.12E-09 4.83E-11 7.40E-10 3.80E-14 1.81E-11 1969 XC-3 Pipe 15CH761 3.32E-08 1.28E-08 4.45E-13 9.84E-12 2.87E-12 7.64E-07 3.08E-07 1.36E-07 1.04E-07 3.02E-06 2.11E-10 1.94E-09 9.41E-10 4.05E-11 6.22E-10 3.19E-14 1.52E-11 1970 XC-3 Pipe 15J1301 7.95E-09 3.05E-09 1.07E-13 2.35E-12 6.85E-13 1.83E-07 7.37E-08 3.26E-08 2.49E-08 7.22E-07 5.04E-11 4.65E-10 2.25E-10 9.70E-12 1.49E-10 7.63E-15 3.64E-12 1971 XC-3 Pipe 15J1401 1.58E-08 6.08E-09 2.12E-13 4.68E-12 1.36E-12 3.64E-07 1.47E-07 6.49E-08 4.95E-08 1.44E-06 1.00E-10 9.26E-10 4.48E-10 1.93E-11 2.96E-10 1.52E-14 7.25E-12 1972 XC-3 Pipe 15J767 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 1973 XC-3 Pipe 15J934 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 1974 XC-3 Pipe 15P1375 3.16E-08 1.22E-08 4.24E-13 9.37E-12 2.73E-12 7.28E-07 2.93E-07 1.30E-07 9.91E-08 2.88E-06 2.01E-10 1.85E-09 8.96E-10 3.86E-11 5.92E-10 3.04E-14 1.45E-11 1975 XC-3 Pipe 15P1376 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1976 XC-3 Pipe 15P1383 3.32E-08 1.28E-08 4.45E-13 9.84E-12 2.87E-12 7.64E-07 3.08E-07 1.36E-07 1.04E-07 3.02E-06 2.11E-10 1.94E-09 9.41E-10 4.05E-11 6.22E-10 3.19E-14 1.52E-11 1977 XC-3 Pipe 15P1384 8.31E-08 3.19E-08 1.11E-12 2.46E-11 7.16E-12 1.91E-06 7.70E-07 3.41E-07 2.60E-07 7.55E-06 5.27E-10 4.86E-09 2.35E-09 1.01E-10 1.55E-09 7.98E-14 3.81E-11 1978 XC-3 Pipe 15P1386 3.32E-08 1.28E-08 4.45E-13 9.84E-12 2.87E-12 7.64E-07 3.08E-07 1.36E-07 1.04E-07 3.02E-06 2.11E-10 1.94E-09 9.41E-10 4.05E-11 6.22E-10 3.19E-14 1.52E-11 1979 XC-3 Pipe 15P1387 3.32E-08 1.28E-08 4.45E-13 9.84E-12 2.87E-12 7.64E-07 3.08E-07 1.36E-07 1.04E-07 3.02E-06 2.11E-10 1.94E-09 9.41E-10 4.05E-11 6.22E-10 3.19E-14 1.52E-11 1980 XC-3 Pipe 15P1399 2.38E-09 9.13E-10 3.19E-14 7.04E-13 2.05E-13 5.47E-08 2.20E-08 9.75E-09 7.44E-09 2.16E-07 1.51E-11 1.39E-10 6.73E-11 2.90E-12 4.45E-11 2.28E-15 1.09E-12 1981 XC-3 Pipe 15P1400 3.16E-08 1.22E-08 4.24E-13 9.37E-12 2.73E-12 7.28E-07 2.93E-07 1.30E-07 9.91E-08 2.88E-06 2.01E-10 1.85E-09 8.96E-10 3.86E-11 5.92E-10 3.04E-14 1.45E-11 1982 XC-3 Pipe 15P1422 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1983 XC-3 Pipe 15P1450 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1984 XC-3 Pipe 15P1451 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1985 XC-3 Pipe 15P1452 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1986 XC-3 Pipe 15P1453 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1987 XC-3 Pipe 15P1454 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1988 XC-3 Pipe 15P1455 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1989 XC-3 Pipe 15P1456 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1990 XC-3 Pipe 15P1457 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1991 XC-3 Pipe 15P1458 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1992 XC-3 Pipe 15P1459 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1993 XC-3 Pipe 15P1460 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1994 XC-3 Pipe 15P1461 6.33E-09 2.43E-09 8.48E-14 1.87E-12 5.46E-13 1.46E-07 5.87E-08 2.60E-08 1.98E-08 5.75E-07 4.01E-11 3.70E-10 1.79E-10 7.72E-12 1.18E-10 6.08E-15 2.90E-12 1995 XC-3 Pipe 15V1087 6.41E-08 2.46E-08 8.59E-13 1.90E-11 5.52E-12 1.47E-06 5.94E-07 2.63E-07 2.01E-07 5.83E-06 4.06E-10 3.75E-09 1.81E-09 7.82E-11 1.20E-09 6.15E-14 2.94E-11 1996 XC-3 Pipe 15V1088 6.41E-08 2.46E-08 8.59E-13 1.90E-11 5.52E-12 1.47E-06 5.94E-07 2.63E-07 2.01E-07 5.83E-06 4.06E-10 3.75E-09 1.81E-09 7.82E-11 1.20E-09 6.15E-14 2.94E-11
WVDP-606 Rev. 1 Page 57 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1997 XC-3 Pipe 15V1093 6.41E-08 2.46E-08 8.59E-13 1.90E-11 5.52E-12 1.47E-06 5.94E-07 2.63E-07 2.01E-07 5.83E-06 4.06E-10 3.75E-09 1.81E-09 7.82E-11 1.20E-09 6.15E-14 2.94E-11 1998 XC-3 Pipe 15V956 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1999 XC-3 Pipe 15V957 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2000 XC-3 Pipe 4IA265 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 2001 XC-3 Pipe 4IA300 1.18E-08 4.55E-09 1.59E-13 3.51E-12 1.02E-12 2.73E-07 1.10E-07 4.86E-08 3.71E-08 1.08E-06 7.51E-11 6.93E-10 3.35E-10 1.45E-11 2.22E-10 1.14E-14 5.43E-12 2002 XC-3 Pipe 4J213A 9.90E-08 3.80E-08 1.33E-12 2.93E-11 8.53E-12 2.28E-06 9.18E-07 4.06E-07 3.10E-07 9.00E-06 6.28E-10 5.79E-09 2.80E-09 1.21E-10 1.85E-09 9.50E-14 4.53E-11 2003 XC-3 Pipe 4J213B 9.90E-08 3.80E-08 1.33E-12 2.93E-11 8.53E-12 2.28E-06 9.18E-07 4.06E-07 3.10E-07 9.00E-06 6.28E-10 5.79E-09 2.80E-09 1.21E-10 1.85E-09 9.50E-14 4.53E-11 2004 XC-3 Pipe 4J217A 7.95E-09 3.05E-09 1.07E-13 2.35E-12 6.85E-13 1.83E-07 7.37E-08 3.26E-08 2.49E-08 7.22E-07 5.04E-11 4.65E-10 2.25E-10 9.70E-12 1.49E-10 7.63E-15 3.64E-12 2005 XC-3 Pipe 4J256B 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2006 XC-3 Pipe 4P180 1.05E-07 4.02E-08 1.40E-12 3.10E-11 9.03E-12 2.41E-06 9.71E-07 4.30E-07 3.28E-07 9.52E-06 6.64E-10 6.13E-09 2.96E-09 1.28E-10 1.96E-09 1.01E-13 4.80E-11 2007 XC-3 Pipe 4P194 6.33E-08 2.43E-08 8.48E-13 1.87E-11 5.46E-12 1.46E-06 5.87E-07 2.60E-07 1.98E-07 5.75E-06 4.01E-10 3.70E-09 1.79E-09 7.72E-11 1.18E-09 6.08E-14 2.90E-11 2008 XC-3 Pipe 4P270 2.77E-08 1.06E-08 3.71E-13 8.19E-12 2.39E-12 6.36E-07 2.57E-07 1.13E-07 8.66E-08 2.52E-06 1.75E-10 1.62E-09 7.83E-10 3.38E-11 5.17E-10 2.66E-14 1.27E-11 2009 XC-3 Pipe 4P296 1.45E-08 5.58E-09 1.95E-13 4.30E-12 1.25E-12 3.34E-07 1.35E-07 5.95E-08 4.55E-08 1.32E-06 9.21E-11 8.50E-10 4.11E-10 1.77E-11 2.72E-10 1.39E-14 6.65E-12 2010 XC-3 Pipe 4P301 1.39E-08 5.33E-09 1.86E-13 4.11E-12 1.20E-12 3.19E-07 1.29E-07 5.69E-08 4.34E-08 1.26E-06 8.80E-11 8.12E-10 3.93E-10 1.69E-11 2.59E-10 1.33E-14 6.35E-12 2011 XC-3 Pipe 4P320 1.98E-08 7.60E-09 2.65E-13 5.86E-12 1.71E-12 4.55E-07 1.84E-07 8.12E-08 6.20E-08 1.80E-06 1.26E-10 1.16E-09 5.60E-10 2.42E-11 3.70E-10 1.90E-14 9.07E-12 2012 XC-3 Pipe 4S159 3.16E-07 1.22E-07 4.24E-12 9.37E-11 2.73E-11 7.28E-06 2.93E-06 1.30E-06 9.91E-07 2.88E-05 2.01E-09 1.85E-08 8.96E-09 3.86E-10 5.92E-09 3.04E-13 1.45E-10 2013 XC-3 Pipe 4SC160 3.16E-07 1.22E-07 4.24E-12 9.37E-11 2.73E-11 7.28E-06 2.93E-06 1.30E-06 9.91E-07 2.88E-05 2.01E-09 1.85E-08 8.96E-09 3.86E-10 5.92E-09 3.04E-13 1.45E-10 2014 XC-3 Pipe 5CH588 1.39E-06 5.33E-07 1.86E-11 4.11E-10 1.20E-10 3.19E-05 1.29E-05 5.69E-06 4.34E-06 1.26E-04 8.80E-09 8.12E-08 3.93E-08 1.69E-09 2.59E-08 1.33E-12 6.35E-10 2015 XC-3 Pipe 5J140A 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2016 XC-3 Pipe 5J140B 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2017 XC-3 Pipe 5J140C 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2018 XC-3 Pipe 5J271A 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2019 XC-3 Pipe 5J271B 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2020 XC-3 Pipe 5J271C 3.96E-09 1.52E-09 5.31E-14 1.17E-12 3.41E-13 9.11E-08 3.67E-08 1.62E-08 1.24E-08 3.60E-07 2.51E-11 2.32E-10 1.12E-10 4.83E-12 7.40E-11 3.80E-15 1.81E-12 2021 XC-3 Pipe 5P134 2.49E-05 9.57E-06 3.34E-10 7.38E-09 2.15E-09 5.73E-04 2.31E-04 1.02E-04 7.80E-05 2.27E-03 1.58E-07 1.46E-06 7.05E-07 3.04E-08 4.66E-07 2.39E-11 1.14E-08 2022 XC-3 Pipe 5P139 2.22E-07 8.52E-08 2.97E-12 6.57E-11 1.91E-11 5.10E-06 2.06E-06 9.09E-07 6.94E-07 2.02E-05 1.41E-09 1.30E-08 6.28E-09 2.71E-10 4.15E-09 2.13E-13 1.02E-10 2023 XC-3 Pipe 5P151 3.32E-09 1.28E-09 4.45E-14 9.84E-13 2.87E-13 7.64E-08 3.08E-08 1.36E-08 1.04E-08 3.02E-07 2.11E-11 1.94E-10 9.41E-11 4.05E-12 6.22E-11 3.19E-15 1.52E-12 2024 XC-3 Pipe 5P196 3.96E-08 1.52E-08 5.31E-13 1.17E-11 3.41E-12 9.11E-07 3.67E-07 1.62E-07 1.24E-07 3.60E-06 2.51E-10 2.32E-09 1.12E-09 4.83E-11 7.40E-10 3.80E-14 1.81E-11 2025 XC-3 Pipe 5P197 4.15E-06 1.60E-06 5.57E-11 1.23E-09 3.58E-10 9.56E-05 3.85E-05 1.70E-05 1.30E-05 3.78E-04 2.63E-08 2.43E-07 1.18E-07 5.07E-09 7.77E-08 3.99E-12 1.90E-09 2026 XC-3 Pipe 5P197 5.94E-06 2.28E-06 7.96E-11 1.76E-09 5.12E-10 1.37E-04 5.51E-05 2.44E-05 1.86E-05 5.40E-04 3.77E-08 3.47E-07 1.68E-07 7.25E-09 1.11E-07 5.70E-12 2.72E-09 2027 XC-3 Pipe 5P253 4.99E-07 1.91E-07 6.68E-12 1.48E-10 4.30E-11 1.15E-05 4.62E-06 2.04E-06 1.56E-06 4.53E-05 3.16E-09 2.92E-08 1.41E-08 6.08E-10 9.32E-09 4.79E-13 2.28E-10 2028 XC-3 Pipe 5P278 3.56E-08 1.37E-08 4.77E-13 1.05E-11 3.07E-12 8.19E-07 3.30E-07 1.46E-07 1.11E-07 3.24E-06 2.26E-10 2.08E-09 1.01E-09 4.35E-11 6.66E-10 3.42E-14 1.63E-11 2029 XC-3 Pipe 5P285 5.35E-05 2.05E-05 7.16E-10 1.58E-08 4.61E-09 1.23E-03 4.96E-04 2.19E-04 1.67E-04 4.86E-03 3.39E-07 3.13E-06 1.51E-06 6.52E-08 1.00E-06 5.13E-11 2.45E-08 2030 XC-3 Pipe 5P383 6.93E-07 2.66E-07 9.29E-12 2.05E-10 5.97E-11 1.59E-05 6.42E-06 2.84E-06 2.17E-06 6.30E-05 4.39E-09 4.05E-08 1.96E-08 8.45E-10 1.30E-08 6.65E-13 3.17E-10 2031 XC-3 Pipe 5P392 1.39E-08 5.33E-09 1.86E-13 4.11E-12 1.20E-12 3.19E-07 1.29E-07 5.69E-08 4.34E-08 1.26E-06 8.80E-11 8.12E-10 3.93E-10 1.69E-11 2.59E-10 1.33E-14 6.35E-12
WVDP-606 Rev. 1 Page 58 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2032 XC-3 Pipe 5P519 2.78E-08 1.07E-08 3.73E-13 8.23E-12 2.40E-12 6.40E-07 2.58E-07 1.14E-07 8.71E-08 2.53E-06 1.76E-10 1.63E-09 7.87E-10 3.39E-11 5.20E-10 2.67E-14 1.27E-11 2033 XC-3 Pipe 5P53 4.00E-08 1.53E-08 5.35E-13 1.18E-11 3.44E-12 9.19E-07 3.70E-07 1.64E-07 1.25E-07 3.63E-06 2.53E-10 2.34E-09 1.13E-09 4.87E-11 7.47E-10 3.84E-14 1.83E-11 2034 XC-3 Pipe 6-71-006 5.54E-06 2.13E-06 7.43E-11 1.64E-09 4.78E-10 1.27E-04 5.14E-05 2.27E-05 1.73E-05 5.04E-04 3.51E-08 3.24E-07 1.57E-07 6.76E-09 1.04E-07 5.32E-12 2.54E-09 2035 XC-3 Pipe 6-71-006 7.95E-06 3.05E-06 1.07E-10 2.35E-09 6.85E-10 1.83E-04 7.37E-05 3.26E-05 2.49E-05 7.22E-04 5.04E-08 4.65E-07 2.25E-07 9.70E-09 1.49E-07 7.63E-12 3.64E-09 2036 XC-3 Pipe 6-71-029 1.16E-08 4.47E-09 1.56E-13 3.44E-12 1.00E-12 2.68E-07 1.08E-07 4.77E-08 3.64E-08 1.06E-06 7.38E-11 6.81E-10 3.29E-10 1.42E-11 2.18E-10 1.12E-14 5.33E-12 2037 XC-3 Pipe 6-71-029 1.66E-08 6.38E-09 2.23E-13 4.92E-12 1.43E-12 3.82E-07 1.54E-07 6.81E-08 5.20E-08 1.51E-06 1.05E-10 9.72E-10 4.70E-10 2.03E-11 3.11E-10 1.60E-14 7.61E-12 2038 XC-3 Pipe 6-71-095 1.66E-05 6.38E-06 2.23E-10 4.92E-09 1.43E-09 3.82E-04 1.54E-04 6.81E-05 5.20E-05 1.51E-03 1.05E-07 9.72E-07 4.70E-07 2.03E-08 3.11E-07 1.60E-11 7.61E-09 2039 XC-3 Pipe 6-71-095 1.86E-06 7.13E-07 2.49E-11 5.50E-10 1.60E-10 4.27E-05 1.72E-05 7.61E-06 5.81E-06 1.69E-04 1.18E-08 1.09E-07 5.26E-08 2.27E-09 3.47E-08 1.78E-12 8.50E-10 2040 XC-3 Pipe 6-71-101 1.95E-06 7.49E-07 2.61E-11 5.77E-10 1.68E-10 4.49E-05 1.81E-05 8.00E-06 6.11E-06 1.77E-04 1.24E-08 1.14E-07 5.52E-08 2.38E-09 3.65E-08 1.87E-12 8.93E-10 2041 XC-3 Pipe 6-71-103 7.95E-08 3.05E-08 1.07E-12 2.35E-11 6.85E-12 1.83E-06 7.37E-07 3.26E-07 2.49E-07 7.22E-06 5.04E-10 4.65E-09 2.25E-09 9.70E-11 1.49E-09 7.63E-14 3.64E-11 2042 XC-3 Pipe 6-71-109 5.54E-06 2.13E-06 7.43E-11 1.64E-09 4.78E-10 1.27E-04 5.14E-05 2.27E-05 1.73E-05 5.04E-04 3.51E-08 3.24E-07 1.57E-07 6.76E-09 1.04E-07 5.32E-12 2.54E-09 2043 XC-3 Pipe 6-71-110 6.93E-06 2.66E-06 9.29E-11 2.05E-09 5.97E-10 1.59E-04 6.42E-05 2.84E-05 2.17E-05 6.30E-04 4.39E-08 4.05E-07 1.96E-07 8.45E-09 1.30E-07 6.65E-12 3.17E-09 2044 XC-3 Pipe 6-71-110 9.90E-06 3.80E-06 1.33E-10 2.93E-09 8.53E-10 2.28E-04 9.18E-05 4.06E-05 3.10E-05 9.00E-04 6.28E-08 5.79E-07 2.80E-07 1.21E-08 1.85E-07 9.50E-12 4.53E-09 2045 XC-3 Pipe 6-71-113 1.42E-07 5.47E-08 1.91E-12 4.21E-11 1.23E-11 3.27E-06 1.32E-06 5.84E-07 4.46E-07 1.29E-05 9.02E-10 8.33E-09 4.03E-09 1.74E-10 2.66E-09 1.37E-13 6.52E-11 2046 XC-3 Pipe 6-71-134 7.51E-06 2.89E-06 1.01E-10 2.22E-09 6.48E-10 1.73E-04 6.97E-05 3.08E-05 2.35E-05 6.83E-04 4.76E-08 4.40E-07 2.13E-07 9.17E-09 1.41E-07 7.21E-12 3.44E-09 2047 XC-3 Pipe 6-71-135 3.32E-05 1.28E-05 4.45E-10 9.84E-09 2.87E-09 7.64E-04 3.08E-04 1.36E-04 1.04E-04 3.02E-03 2.11E-07 1.94E-06 9.41E-07 4.05E-08 6.22E-07 3.19E-11 1.52E-08 2048 XC-3 Pipe 6-71-136 1.83E-07 7.02E-08 2.45E-12 5.41E-11 1.58E-11 4.20E-06 1.69E-06 7.49E-07 5.72E-07 1.66E-05 1.16E-09 1.07E-08 5.17E-09 2.23E-10 3.42E-09 1.75E-13 8.37E-11 2049 XC-3 Pipe 6-71-142 5.54E-08 2.13E-08 7.43E-13 1.64E-11 4.78E-12 1.27E-06 5.14E-07 2.27E-07 1.73E-07 5.04E-06 3.51E-10 3.24E-09 1.57E-09 6.76E-11 1.04E-09 5.32E-14 2.54E-11 2050 XC-3 Pipe 6-71-143 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2051 XC-3 Pipe 6-71-146 1.58E-08 6.08E-09 2.12E-13 4.68E-12 1.36E-12 3.64E-07 1.47E-07 6.49E-08 4.95E-08 1.44E-06 1.00E-10 9.26E-10 4.48E-10 1.93E-11 2.96E-10 1.52E-14 7.25E-12 2052 XC-3 Pipe 6-71-147 7.95E-09 3.05E-09 1.07E-13 2.35E-12 6.85E-13 1.83E-07 7.37E-08 3.26E-08 2.49E-08 7.22E-07 5.04E-11 4.65E-10 2.25E-10 9.70E-12 1.49E-10 7.63E-15 3.64E-12 2053 XC-3 Pipe 6-71-150 1.68E-08 6.44E-09 2.25E-13 4.96E-12 1.44E-12 3.86E-07 1.55E-07 6.87E-08 5.25E-08 1.52E-06 1.06E-10 9.81E-10 4.74E-10 2.05E-11 3.13E-10 1.61E-14 7.68E-12 2054 XC-3 Pipe 6-71-150 2.40E-08 9.21E-09 3.21E-13 7.10E-12 2.07E-12 5.52E-07 2.22E-07 9.84E-08 7.51E-08 2.18E-06 1.52E-10 1.40E-09 6.79E-10 2.93E-11 4.49E-10 2.30E-14 1.10E-11 2055 XC-3 Pipe 6-71-155 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2056 XC-3 Pipe 6-71-162 1.55E-07 5.97E-08 2.08E-12 4.60E-11 1.34E-11 3.57E-06 1.44E-06 6.37E-07 4.86E-07 1.41E-05 9.85E-10 9.09E-09 4.40E-09 1.90E-10 2.90E-09 1.49E-13 7.11E-11 2057 XC-3 Pipe 6-71-200 1.99E-05 7.66E-06 2.67E-10 5.90E-09 1.72E-09 4.59E-04 1.85E-04 8.18E-05 6.24E-05 1.81E-03 1.26E-07 1.17E-06 5.64E-07 2.43E-08 3.73E-07 1.91E-11 9.13E-09 2058 XC-3 Pipe 6-71-201 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2059 XC-3 Pipe 6-71-202 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2060 XC-3 Pipe 6-71-203 4.15E-08 1.60E-08 5.57E-13 1.23E-11 3.58E-12 9.56E-07 3.85E-07 1.70E-07 1.30E-07 3.78E-06 2.63E-10 2.43E-09 1.18E-09 5.07E-11 7.77E-10 3.99E-14 1.90E-11 2061 XC-3 Pipe 6-71-204 2.66E-12 1.02E-12 3.56E-17 7.87E-16 2.29E-16 6.12E-11 2.46E-11 1.09E-11 8.32E-12 2.42E-10 1.69E-14 1.56E-13 7.52E-14 3.24E-15 4.97E-14 2.55E-18 1.22E-15 2062 XC-3 Pipe 6-71-214 7.51E-06 2.89E-06 1.01E-10 2.22E-09 6.48E-10 1.73E-04 6.97E-05 3.08E-05 2.35E-05 6.83E-04 4.76E-08 4.40E-07 2.13E-07 9.17E-09 1.41E-07 7.21E-12 3.44E-09 2063 XC-3 Pipe 6-71-216 7.51E-06 2.89E-06 1.01E-10 2.22E-09 6.48E-10 1.73E-04 6.97E-05 3.08E-05 2.35E-05 6.83E-04 4.76E-08 4.40E-07 2.13E-07 9.17E-09 1.41E-07 7.21E-12 3.44E-09 2064 XC-3 Pipe 6-71-225 9.97E-06 3.83E-06 1.34E-10 2.95E-09 8.60E-10 2.29E-04 9.24E-05 4.09E-05 3.12E-05 9.06E-04 6.32E-08 5.83E-07 2.82E-07 1.22E-08 1.86E-07 9.57E-12 4.57E-09 2065 XC-3 Pipe 6-71-23 9.47E-09 3.63E-09 1.27E-13 2.80E-12 8.16E-13 2.18E-07 8.77E-08 3.88E-08 2.96E-08 8.60E-07 6.00E-11 5.54E-10 2.68E-10 1.15E-11 1.77E-10 9.09E-15 4.34E-12 2066 XC-3 Pipe 6-71-234 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11
WVDP-606 Rev. 1 Page 59 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2067 XC-3 Pipe 6-71-245 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2068 XC-3 Pipe 6-71-308 1.11E-08 4.25E-09 1.48E-13 3.27E-12 9.53E-13 2.54E-07 1.02E-07 4.53E-08 3.46E-08 1.00E-06 7.01E-11 6.47E-10 3.13E-10 1.35E-11 2.07E-10 1.06E-14 5.06E-12 2069 XC-3 Pipe 6-71-314 1.66E-07 6.38E-08 2.23E-12 4.92E-11 1.43E-11 3.82E-06 1.54E-06 6.81E-07 5.20E-07 1.51E-05 1.05E-09 9.72E-09 4.70E-09 2.03E-10 3.11E-09 1.60E-13 7.61E-11 2070 XC-3 Pipe 6-71-390 1.66E-07 6.38E-08 2.23E-12 4.92E-11 1.43E-11 3.82E-06 1.54E-06 6.81E-07 5.20E-07 1.51E-05 1.05E-09 9.72E-09 4.70E-09 2.03E-10 3.11E-09 1.60E-13 7.61E-11 2071 XC-3 Pipe 6-71-390 2.38E-07 9.13E-08 3.19E-12 7.04E-11 2.05E-11 5.47E-06 2.20E-06 9.75E-07 7.44E-07 2.16E-05 1.51E-09 1.39E-08 6.73E-09 2.90E-10 4.45E-09 2.28E-13 1.09E-10 2072 XC-3 Pipe 6-71-407 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2073 XC-3 Pipe 6-71-409 2.59E-08 9.96E-09 3.48E-13 7.68E-12 2.24E-12 5.97E-07 2.40E-07 1.06E-07 8.12E-08 2.36E-06 1.64E-10 1.52E-09 7.34E-10 3.16E-11 4.85E-10 2.49E-14 1.19E-11 2074 XC-3 Pipe 6-71-409 3.71E-08 1.43E-08 4.98E-13 1.10E-11 3.20E-12 8.54E-07 3.44E-07 1.52E-07 1.16E-07 3.38E-06 2.35E-10 2.17E-09 1.05E-09 4.53E-11 6.94E-10 3.57E-14 1.70E-11 2075 XC-3 Pipe 6-71-412 2.38E-09 9.13E-10 3.19E-14 7.04E-13 2.05E-13 5.47E-08 2.20E-08 9.75E-09 7.44E-09 2.16E-07 1.51E-11 1.39E-10 6.73E-11 2.90E-12 4.45E-11 2.28E-15 1.09E-12 2076 XC-3 Pipe 6-71-417 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2077 XC-3 Pipe 6-71-438 5.54E-09 2.13E-09 7.43E-14 1.64E-12 4.78E-13 1.27E-07 5.14E-08 2.27E-08 1.73E-08 5.04E-07 3.51E-11 3.24E-10 1.57E-10 6.76E-12 1.04E-10 5.32E-15 2.54E-12 2078 XC-3 Pipe 6-71-446 4.75E-09 1.82E-09 6.36E-14 1.41E-12 4.09E-13 1.09E-07 4.40E-08 1.95E-08 1.49E-08 4.32E-07 3.01E-11 2.78E-10 1.34E-10 5.79E-12 8.88E-11 4.56E-15 2.17E-12 2079 XC-3 Pipe 6-71-448 5.54E-09 2.13E-09 7.43E-14 1.64E-12 4.78E-13 1.27E-07 5.14E-08 2.27E-08 1.73E-08 5.04E-07 3.51E-11 3.24E-10 1.57E-10 6.76E-12 1.04E-10 5.32E-15 2.54E-12 2080 XC-3 Pipe 6-71-450 7.95E-09 3.05E-09 1.07E-13 2.35E-12 6.85E-13 1.83E-07 7.37E-08 3.26E-08 2.49E-08 7.22E-07 5.04E-11 4.65E-10 2.25E-10 9.70E-12 1.49E-10 7.63E-15 3.64E-12 2081 XC-3 Pipe 6-71-452 1.11E-07 4.25E-08 1.48E-12 3.27E-11 9.53E-12 2.54E-06 1.02E-06 4.53E-07 3.46E-07 1.00E-05 7.01E-10 6.47E-09 3.13E-09 1.35E-10 2.07E-09 1.06E-13 5.06E-11 2082 XC-3 Pipe 6-71-601 1.73E-07 6.66E-08 2.32E-12 5.13E-11 1.49E-11 3.99E-06 1.61E-06 7.11E-07 5.43E-07 1.58E-05 1.10E-09 1.01E-08 4.91E-09 2.12E-10 3.24E-09 1.66E-13 7.94E-11 2083 XC-3 Pipe 6-71-609 5.54E-06 2.13E-06 7.43E-11 1.64E-09 4.78E-10 1.27E-04 5.14E-05 2.27E-05 1.73E-05 5.04E-04 3.51E-08 3.24E-07 1.57E-07 6.76E-09 1.04E-07 5.32E-12 2.54E-09 2084 XC-3 Pipe 6-71-610 9.97E-06 3.83E-06 1.34E-10 2.95E-09 8.60E-10 2.29E-04 9.24E-05 4.09E-05 3.12E-05 9.06E-04 6.32E-08 5.83E-07 2.82E-07 1.22E-08 1.86E-07 9.57E-12 4.57E-09 2085 XC-3 Pipe 6-71-640 7.95E-09 3.05E-09 1.07E-13 2.35E-12 6.85E-13 1.83E-07 7.37E-08 3.26E-08 2.49E-08 7.22E-07 5.04E-11 4.65E-10 2.25E-10 9.70E-12 1.49E-10 7.63E-15 3.64E-12 2086 XC-3 Pipe 6-71-645 4.75E-07 1.82E-07 6.36E-12 1.41E-10 4.09E-11 1.09E-05 4.40E-06 1.95E-06 1.49E-06 4.32E-05 3.01E-09 2.78E-08 1.34E-08 5.79E-10 8.88E-09 4.56E-13 2.17E-10 2087 XC-3 Pipe 6-71-698 6.02E-07 2.31E-07 8.07E-12 1.78E-10 5.19E-11 1.38E-05 5.58E-06 2.47E-06 1.88E-06 5.47E-05 3.82E-09 3.52E-08 1.70E-08 7.34E-10 1.13E-08 5.78E-13 2.76E-10 2088 XC-3 Pipe 6-71-H-200 2.85E-05 1.09E-05 3.81E-10 8.43E-09 2.45E-09 6.55E-04 2.64E-04 1.17E-04 8.91E-05 2.59E-03 1.80E-07 1.67E-06 8.06E-07 3.47E-08 5.32E-07 2.73E-11 1.30E-08 2089 XC-3 Pipe 6-71-H-222 1.78E-05 6.85E-06 2.39E-10 5.28E-09 1.54E-09 4.10E-04 1.65E-04 7.32E-05 5.59E-05 1.62E-03 1.13E-07 1.04E-06 5.05E-07 2.18E-08 3.34E-07 1.71E-11 8.17E-09 2090 XC-3 Pipe 6-71-H-231 1.78E-05 6.85E-06 2.39E-10 5.28E-09 1.54E-09 4.10E-04 1.65E-04 7.32E-05 5.59E-05 1.62E-03 1.13E-07 1.04E-06 5.05E-07 2.18E-08 3.34E-07 1.71E-11 8.17E-09 2091 XC-3 Pipe 6-71-H-242 1.78E-05 6.85E-06 2.39E-10 5.28E-09 1.54E-09 4.10E-04 1.65E-04 7.32E-05 5.59E-05 1.62E-03 1.13E-07 1.04E-06 5.05E-07 2.18E-08 3.34E-07 1.71E-11 8.17E-09 2092 XC-3 Pipe 6-71-H-262 1.78E-05 6.85E-06 2.39E-10 5.28E-09 1.54E-09 4.10E-04 1.65E-04 7.32E-05 5.59E-05 1.62E-03 1.13E-07 1.04E-06 5.05E-07 2.18E-08 3.34E-07 1.71E-11 8.17E-09 2093 XC-3 Pipe 6-71-H-436 1.78E-05 6.85E-06 2.39E-10 5.28E-09 1.54E-09 4.10E-04 1.65E-04 7.32E-05 5.59E-05 1.62E-03 1.13E-07 1.04E-06 5.05E-07 2.18E-08 3.34E-07 1.71E-11 8.17E-09 1087 XCR 160' Ceiling 1.84E-04 6.77E-05 9.11E-09 2.29E-07 5.42E-09 9.68E-06 2.95E-06 2.21E-06 1.67E-06 2.91E-05 1.94E-06 1.52E-07 7.08E-08 3.30E-09 4.76E-08 1.77E-10 8.44E-08 1188 XCR 160' Cell Duct/Filter Housing 1.16E-04 4.27E-05 5.75E-09 1.44E-07 3.42E-09 6.11E-06 1.86E-06 1.40E-06 1.05E-06 1.84E-05 1.22E-06 9.58E-08 4.47E-08 2.08E-09 3.00E-08 1.12E-10 5.33E-08 659 XCR 160' E Wall 6.62E-06 2.43E-06 3.27E-10 8.21E-09 1.95E-10 3.48E-07 1.06E-07 7.94E-08 5.99E-08 1.05E-06 6.95E-08 5.46E-09 2.54E-09 1.19E-10 1.71E-09 6.36E-12 3.03E-09 661 XCR 160' Floor 6.54E-04 2.40E-04 3.23E-08 8.11E-07 1.92E-08 3.43E-05 1.05E-05 7.85E-06 5.92E-06 1.03E-04 6.87E-06 5.39E-07 2.51E-07 1.17E-08 1.69E-07 6.28E-10 3.00E-07 657 XCR 160' N Wall 1.10E-04 4.03E-05 5.42E-09 1.36E-07 3.23E-09 5.76E-06 1.76E-06 1.32E-06 9.93E-07 1.73E-05 1.15E-06 9.04E-08 4.21E-08 1.96E-09 2.83E-08 1.05E-10 5.03E-08 658 XCR 160' S Wall 1.09E-04 4.00E-05 5.38E-09 1.35E-07 3.20E-09 5.72E-06 1.74E-06 1.31E-06 9.86E-07 1.72E-05 1.14E-06 8.98E-08 4.19E-08 1.95E-09 2.81E-08 1.05E-10 4.99E-08 660 XCR 160' W Wall 8.71E-06 3.19E-06 4.30E-10 1.08E-08 2.56E-10 4.57E-07 1.39E-07 1.04E-07 7.88E-08 1.38E-06 9.14E-08 7.17E-09 3.34E-09 1.56E-10 2.25E-09 8.36E-12 3.99E-09 1957 XCR 160' Pipe 15BA3342 3.34E-09 1.22E-09 1.65E-13 4.14E-12 9.81E-14 1.75E-10 5.34E-11 4.00E-11 3.02E-11 5.27E-10 3.50E-11 2.75E-12 1.28E-12 5.97E-14 8.61E-13 3.20E-15 1.53E-12
WVDP-606 Rev. 1 Page 60 of 76 Hydraulic Hammer Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 919 XSA 131' Ceiling 4.55E-06 1.67E-06 2.25E-10 5.64E-09 1.34E-10 2.39E-07 7.28E-08 5.46E-08 4.12E-08 7.19E-07 4.78E-08 3.75E-09 1.75E-09 8.14E-11 1.17E-09 4.37E-12 2.08E-09 917 XSA 131' E Wall 1.85E-07 6.79E-08 9.14E-12 2.29E-10 5.44E-12 9.72E-09 2.96E-09 2.22E-09 1.67E-09 2.92E-08 1.94E-09 1.53E-10 7.11E-11 3.31E-12 4.77E-11 1.78E-13 8.48E-11 920 XSA 131' Floor 2.28E-07 8.35E-08 1.12E-11 2.82E-10 6.69E-12 1.19E-08 3.64E-09 2.73E-09 2.06E-09 3.59E-08 2.39E-09 1.87E-10 8.74E-11 4.07E-12 5.87E-11 2.18E-13 1.04E-10 915 XSA 131' N Wall 9.88E-06 3.62E-06 4.88E-10 1.22E-08 2.90E-10 5.18E-07 1.58E-07 1.19E-07 8.94E-08 1.56E-06 1.04E-07 8.14E-09 3.79E-09 1.77E-10 2.55E-09 9.48E-12 4.52E-09 916 XSA 131' S Wall 9.58E-06 3.52E-06 4.73E-10 1.19E-08 2.82E-10 5.03E-07 1.53E-07 1.15E-07 8.67E-08 1.51E-06 1.01E-07 7.90E-09 3.68E-09 1.72E-10 2.47E-09 9.20E-12 4.39E-09 918 XSA 131' W Wall 4.63E-07 1.70E-07 2.29E-11 5.74E-10 1.36E-11 2.43E-08 7.41E-09 5.56E-09 4.19E-09 7.32E-08 4.86E-09 3.82E-10 1.78E-10 8.29E-12 1.19E-10 4.45E-13 2.12E-10
WVDP-606 Rev. 1 Page 61 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2976 1C Sampler Pipe 4P501 4.76E-06 8.24E-06 0.00E+00 0.00E+00 8.62E-12 9.00E-06 4.64E-06 3.46E-06 2.69E-06 6.05E-05 0.00E+00 5.19E-17 4.00E-11 1.02E-14 0.00E+00 4.57E-12 2.18E-09 2977 1C Sampler Pipe 4P501 4.29E-06 7.41E-06 0.00E+00 0.00E+00 7.76E-12 8.10E-06 4.18E-06 3.12E-06 2.42E-06 5.44E-05 0.00E+00 4.67E-17 3.60E-11 9.21E-15 0.00E+00 4.11E-12 1.96E-09 2978 1C Sampler Pipe 4P622 1.08E-08 1.86E-08 0.00E+00 0.00E+00 1.95E-14 2.04E-08 1.05E-08 7.83E-09 6.08E-09 1.37E-07 0.00E+00 1.17E-19 9.04E-14 2.32E-17 0.00E+00 1.03E-14 4.93E-12 2967 Cell Access Aisle CAA Pipe 15V961 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2907 COA 114' Pipe 13CW142 1.68E-08 6.17E-09 8.31E-13 2.09E-11 4.95E-13 8.83E-10 2.69E-10 2.02E-10 1.52E-10 2.66E-09 1.77E-10 1.39E-11 6.46E-12 3.01E-13 4.34E-12 1.62E-14 7.71E-12 2908 COA 114' Pipe 13S133 4.81E-07 1.76E-07 2.37E-11 5.96E-10 1.41E-11 2.52E-08 7.69E-09 5.77E-09 4.35E-09 7.59E-08 5.05E-09 3.96E-10 1.85E-10 8.60E-12 1.24E-10 4.61E-13 2.20E-10 2909 COA 114' Pipe 13S134 5.59E-09 2.05E-09 2.76E-13 6.93E-12 1.64E-13 2.93E-10 8.94E-11 6.71E-11 5.06E-11 8.83E-10 5.87E-11 4.61E-12 2.15E-12 1.00E-13 1.44E-12 5.37E-15 2.56E-12 2910 COA 114' Pipe 13S139 6.49E-08 2.38E-08 3.21E-12 8.05E-11 1.91E-12 3.41E-09 1.04E-09 7.79E-10 5.87E-10 1.03E-08 6.81E-10 5.35E-11 2.49E-11 1.16E-12 1.67E-11 6.23E-14 2.97E-11 2915 COA 114' Pipe 14CH83 1.68E-05 6.17E-06 8.31E-10 2.09E-08 4.95E-10 8.83E-07 2.69E-07 2.02E-07 1.52E-07 2.66E-06 1.77E-07 1.39E-08 6.46E-09 3.01E-10 4.34E-09 1.62E-11 7.71E-09 2916 COA 114' Pipe 15DW312 7.68E-07 2.82E-07 3.79E-11 9.52E-10 2.26E-11 4.03E-08 1.23E-08 9.22E-09 6.95E-09 1.21E-07 8.07E-09 6.33E-10 2.95E-10 1.37E-11 1.98E-10 7.37E-13 3.52E-10 2917 COA 114' Pipe 15J1298 1.44E-06 5.29E-07 7.12E-11 1.79E-09 4.24E-11 7.57E-08 2.31E-08 1.73E-08 1.30E-08 2.28E-07 1.51E-08 1.19E-09 5.53E-10 2.58E-11 3.72E-10 1.38E-12 6.60E-10 2918 COA 114' Pipe 15J1300 9.58E-07 3.52E-07 4.73E-11 1.19E-09 2.82E-11 5.03E-08 1.53E-08 1.15E-08 8.67E-09 1.51E-07 1.01E-08 7.90E-10 3.68E-10 1.72E-11 2.47E-10 9.20E-13 4.39E-10 2919 COA 114' Pipe 15J1315 2.88E-06 1.06E-06 1.42E-10 3.57E-09 8.47E-11 1.51E-07 4.61E-08 3.46E-08 2.61E-08 4.55E-07 3.03E-08 2.37E-09 1.11E-09 5.16E-11 7.44E-10 2.77E-12 1.32E-09 2921 COA 114' Pipe 15S724 4.81E-07 1.76E-07 2.37E-11 5.96E-10 1.41E-11 2.52E-08 7.69E-09 5.77E-09 4.35E-09 7.59E-08 5.05E-09 3.96E-10 1.85E-10 8.60E-12 1.24E-10 4.61E-13 2.20E-10 2922 COA 114' Pipe 15S725 4.21E-07 1.54E-07 2.08E-11 5.22E-10 1.24E-11 2.21E-08 6.73E-09 5.05E-09 3.81E-09 6.65E-08 4.42E-09 3.47E-10 1.62E-10 7.53E-12 1.09E-10 4.04E-13 1.93E-10 2924 COA 114' Pipe 15V969 5.29E-04 1.94E-04 2.61E-08 6.56E-07 1.55E-08 2.78E-05 8.46E-06 6.35E-06 4.79E-06 8.36E-05 5.55E-06 4.36E-07 2.03E-07 9.47E-09 1.36E-07 5.08E-10 2.42E-07 2925 COA 114' Pipe 15V982 2.10E-03 7.71E-04 1.04E-07 2.60E-06 6.17E-08 1.10E-04 3.36E-05 2.52E-05 1.90E-05 3.32E-04 2.20E-05 1.73E-06 8.06E-07 3.76E-08 5.42E-07 2.02E-09 9.62E-07 2926 COA 114' Pipe 3CW34 1.11E-08 4.08E-09 5.49E-13 1.38E-11 3.27E-13 5.84E-10 1.78E-10 1.33E-10 1.01E-10 1.76E-09 1.17E-10 9.16E-12 4.27E-12 1.99E-13 2.87E-12 1.07E-14 5.09E-12 2927 COA 114' Pipe 3CW8 1.81E-08 6.66E-09 8.96E-13 2.25E-11 5.33E-13 9.52E-10 2.90E-10 2.18E-10 1.64E-10 2.87E-09 1.90E-10 1.49E-11 6.97E-12 3.25E-13 4.68E-12 1.74E-14 8.31E-12 2928 COA 114' Pipe 3S86 1.18E-07 4.32E-08 5.82E-12 1.46E-10 3.46E-12 6.18E-09 1.88E-09 1.41E-09 1.07E-09 1.86E-08 1.24E-09 9.70E-11 4.52E-11 2.11E-12 3.04E-11 1.13E-13 5.39E-11 2929 COA 114' Pipe 4CW460 1.68E-06 6.17E-07 8.31E-11 2.09E-09 4.95E-11 8.83E-08 2.69E-08 2.02E-08 1.52E-08 2.66E-07 1.77E-08 1.39E-09 6.46E-10 3.01E-11 4.34E-10 1.62E-12 7.71E-10 2930 COA 114' Pipe 4CW461 3.37E-06 1.23E-06 1.66E-10 4.17E-09 9.89E-11 1.77E-07 5.38E-08 4.04E-08 3.05E-08 5.32E-07 3.53E-08 2.77E-09 1.29E-09 6.02E-11 8.68E-10 3.23E-12 1.54E-09 2932 COA 114' Pipe 4S464 1.08E-07 3.97E-08 5.35E-12 1.34E-10 3.18E-12 5.68E-09 1.73E-09 1.30E-09 9.80E-10 1.71E-08 1.14E-09 8.92E-11 4.16E-11 1.94E-12 2.79E-11 1.04E-13 4.96E-11 2933 COA 114' Pipe 4S465 1.62E-07 5.96E-08 8.02E-12 2.01E-10 4.77E-12 8.53E-09 2.60E-09 1.95E-09 1.47E-09 2.57E-08 1.71E-09 1.34E-10 6.24E-11 2.91E-12 4.19E-11 1.56E-13 7.44E-11 2934 COA 114' Pipe 4S466 3.03E-07 1.11E-07 1.50E-11 3.76E-10 8.90E-12 1.59E-08 4.85E-09 3.63E-09 2.74E-09 4.79E-08 3.18E-09 2.50E-10 1.16E-10 5.42E-12 7.81E-11 2.91E-13 1.39E-10 2935 COA 114' Pipe 4S470 3.37E-06 1.23E-06 1.66E-10 4.17E-09 9.89E-11 1.77E-07 5.38E-08 4.04E-08 3.05E-08 5.32E-07 3.53E-08 2.77E-09 1.29E-09 6.02E-11 8.68E-10 3.23E-12 1.54E-09 2936 COA 114' Pipe 4S471 8.41E-08 3.09E-08 4.16E-12 1.04E-10 2.47E-12 4.42E-09 1.35E-09 1.01E-09 7.61E-10 1.33E-08 8.83E-10 6.93E-11 3.23E-11 1.51E-12 2.17E-11 8.08E-14 3.85E-11 2942 COA 114' Pipe 4S78 8.63E-07 3.17E-07 4.26E-11 1.07E-09 2.54E-11 4.53E-08 1.38E-08 1.04E-08 7.81E-09 1.36E-07 9.06E-09 7.11E-10 3.31E-10 1.55E-11 2.23E-10 8.29E-13 3.95E-10 2943 COA 114' Pipe 4S84 1.06E-06 3.89E-07 5.24E-11 1.32E-09 3.12E-11 5.57E-08 1.70E-08 1.27E-08 9.60E-09 1.68E-07 1.11E-08 8.74E-10 4.07E-10 1.90E-11 2.74E-10 1.02E-12 4.86E-10 2944 COA 114' Pipe 4S85 1.98E-06 7.28E-07 9.79E-11 2.46E-09 5.83E-11 1.04E-07 3.17E-08 2.38E-08 1.79E-08 3.13E-07 2.08E-08 1.63E-09 7.61E-10 3.55E-11 5.11E-10 1.90E-12 9.08E-10 2945 COA 114' Pipe 4S90 1.06E-06 3.89E-07 5.24E-11 1.32E-09 3.12E-11 5.57E-08 1.70E-08 1.27E-08 9.60E-09 1.68E-07 1.11E-08 8.74E-10 4.07E-10 1.90E-11 2.74E-10 1.02E-12 4.86E-10 2946 COA 114' Pipe 4UA468 1.81E-06 6.63E-07 8.93E-11 2.24E-09 5.31E-11 9.49E-08 2.89E-08 2.17E-08 1.64E-08 2.85E-07 1.90E-08 1.49E-09 6.94E-10 3.23E-11 4.66E-10 1.73E-12 8.28E-10 2947 COA 114' Pipe 4UA502 7.21E-05 2.65E-05 3.56E-09 8.94E-08 2.12E-09 3.79E-06 1.15E-06 8.66E-07 6.53E-07 1.14E-05 7.57E-07 5.94E-08 2.77E-08 1.29E-09 1.86E-08 6.92E-11 3.30E-08 2948 COA 114' Pipe 4UA82 1.34E-07 4.91E-08 6.61E-12 1.66E-10 3.94E-12 7.03E-09 2.14E-09 1.61E-09 1.21E-09 2.12E-08 1.41E-09 1.10E-10 5.14E-11 2.40E-12 3.45E-11 1.29E-13 6.13E-11
WVDP-606 Rev. 1 Page 62 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2949 COA 114' Pipe 4UA83 8.63E-07 3.17E-07 4.26E-11 1.07E-09 2.54E-11 4.53E-08 1.38E-08 1.04E-08 7.81E-09 1.36E-07 9.06E-09 7.11E-10 3.31E-10 1.55E-11 2.23E-10 8.29E-13 3.95E-10 2953 COA 114' Pipe 7DW117 2.12E-08 7.79E-09 1.05E-12 2.63E-11 6.24E-13 1.11E-09 3.39E-10 2.55E-10 1.92E-10 3.35E-09 2.23E-10 1.75E-11 8.15E-12 3.80E-13 5.47E-12 2.04E-14 9.72E-12 2956 COA 114' Pipe 7J56A 2.41E-06 8.83E-07 1.19E-10 2.98E-09 7.08E-11 1.26E-07 3.85E-08 2.89E-08 2.18E-08 3.80E-07 2.53E-08 1.98E-09 9.24E-10 4.31E-11 6.21E-10 2.31E-12 1.10E-09 2957 COA 114' Pipe 7J56B 7.21E-06 2.65E-06 3.56E-10 8.94E-09 2.12E-10 3.79E-07 1.15E-07 8.66E-08 6.53E-08 1.14E-06 7.57E-08 5.94E-09 2.77E-09 1.29E-10 1.86E-09 6.92E-12 3.30E-09 2958 COA 114' Pipe 7J56C 7.21E-06 2.65E-06 3.56E-10 8.94E-09 2.12E-10 3.79E-07 1.15E-07 8.66E-08 6.53E-08 1.14E-06 7.57E-08 5.94E-09 2.77E-09 1.29E-10 1.86E-09 6.92E-12 3.30E-09 2959 COA 114' Pipe 7S12 2.88E-07 1.06E-07 1.42E-11 3.57E-10 8.47E-12 1.51E-08 4.61E-09 3.46E-09 2.61E-09 4.55E-08 3.03E-09 2.37E-10 1.11E-10 5.16E-12 7.44E-11 2.77E-13 1.32E-10 2960 COA 114' Pipe 7S144 2.63E-07 9.64E-08 1.30E-11 3.26E-10 7.72E-12 1.38E-08 4.20E-09 3.15E-09 2.38E-09 4.15E-08 2.76E-09 2.16E-10 1.01E-10 4.70E-12 6.78E-11 2.52E-13 1.20E-10 2962 COA 114' Pipe 7S58 5.05E-06 1.85E-06 2.49E-10 6.26E-09 1.48E-10 2.65E-07 8.08E-08 6.06E-08 4.57E-08 7.98E-07 5.30E-08 4.16E-09 1.94E-09 9.04E-11 1.30E-09 4.85E-12 2.31E-09 2963 COA 114' Pipe 7S61 2.25E-06 8.27E-07 1.11E-10 2.79E-09 6.62E-11 1.18E-07 3.60E-08 2.70E-08 2.04E-08 3.56E-07 2.37E-08 1.86E-09 8.65E-10 4.03E-11 5.81E-10 2.16E-12 1.03E-09 2965 COA 114' Pipe 7SC107 1.92E-06 7.06E-07 9.50E-11 2.39E-09 5.66E-11 1.01E-07 3.08E-08 2.31E-08 1.74E-08 3.04E-07 2.02E-08 1.59E-09 7.39E-10 3.44E-11 4.96E-10 1.85E-12 8.81E-10 2966 COA 114' Pipe 7UA52 1.68E-06 6.17E-07 8.31E-11 2.09E-09 4.95E-11 8.83E-08 2.69E-08 2.02E-08 1.52E-08 2.66E-07 1.77E-08 1.39E-09 6.46E-10 3.01E-11 4.34E-10 1.62E-12 7.71E-10 2894 CPC Pipe 3P121 2.14E-05 5.75E-05 2.57E-09 5.75E-08 2.44E-10 3.09E-06 1.08E-06 7.95E-07 6.02E-07 9.39E-06 7.57E-08 2.96E-08 1.40E-08 9.84E-11 1.10E-09 2.06E-11 9.82E-09 2895 CPC Pipe 3P90 8.48E-06 2.27E-05 1.02E-09 2.27E-08 9.67E-11 1.22E-06 4.26E-07 3.15E-07 2.38E-07 3.71E-06 2.99E-08 1.17E-08 5.55E-09 3.89E-11 4.36E-10 8.14E-12 3.88E-09 2896 CPC Pipe 3P91 5.65E-05 1.51E-04 6.78E-09 1.51E-07 6.44E-10 8.14E-06 2.84E-06 2.10E-06 1.59E-06 2.48E-05 2.00E-07 7.80E-08 3.70E-08 2.59E-10 2.91E-09 5.43E-11 2.59E-08 2897 CPC Pipe 3P92 2.14E-05 5.75E-05 2.57E-09 5.75E-08 2.44E-10 3.09E-06 1.08E-06 7.95E-07 6.02E-07 9.39E-06 7.57E-08 2.96E-08 1.40E-08 9.84E-11 1.10E-09 2.06E-11 9.82E-09 2898 CPC Pipe 7P10 5.35E-05 1.43E-04 6.42E-09 1.43E-07 6.10E-10 7.71E-06 2.69E-06 1.99E-06 1.50E-06 2.34E-05 1.89E-07 7.39E-08 3.51E-08 2.46E-10 2.75E-09 5.14E-11 2.45E-08 2899 CPC Pipe 7P13 1.43E-05 3.83E-05 1.72E-09 3.83E-08 1.63E-10 2.06E-06 7.19E-07 5.30E-07 4.02E-07 6.26E-06 5.05E-08 1.97E-08 9.36E-09 6.56E-11 7.35E-10 1.37E-11 6.55E-09 2900 CPC Pipe 7P153 1.01E-05 2.69E-05 1.21E-09 2.69E-08 1.15E-10 1.45E-06 5.06E-07 3.73E-07 2.83E-07 4.40E-06 3.55E-08 1.39E-08 6.59E-09 4.61E-11 5.17E-10 9.65E-12 4.60E-09 2901 CPC Pipe 7P25 1.96E-05 5.27E-05 2.36E-09 5.27E-08 2.24E-10 2.83E-06 9.88E-07 7.29E-07 5.52E-07 8.61E-06 6.94E-08 2.71E-08 1.29E-08 9.02E-11 1.01E-09 1.89E-11 9.00E-09 2902 CPC Pipe 7P59 9.38E-05 2.51E-04 1.13E-08 2.51E-07 1.07E-09 1.35E-05 4.72E-06 3.48E-06 2.63E-06 4.11E-05 3.31E-07 1.29E-07 6.14E-08 4.30E-10 4.82E-09 9.00E-11 4.29E-08 2903 CPC Pipe 7P62 3.48E-05 9.32E-05 4.17E-09 9.32E-08 3.97E-10 5.01E-06 1.75E-06 1.29E-06 9.77E-07 1.52E-05 1.23E-07 4.80E-08 2.28E-08 1.60E-10 1.79E-09 3.34E-11 1.59E-08 2904 CPC Pipe 7P81 3.56E-06 9.54E-06 4.27E-10 9.54E-09 4.06E-11 5.13E-07 1.79E-07 1.32E-07 1.00E-07 1.56E-06 1.26E-08 4.91E-09 2.33E-09 1.63E-11 1.83E-10 3.42E-12 1.63E-09 2905 CPC Pipe 7P96 1.67E-04 4.47E-04 2.00E-08 4.47E-07 1.90E-09 2.40E-05 8.39E-06 6.19E-06 4.69E-06 7.31E-05 5.89E-07 2.30E-07 1.09E-07 7.66E-10 8.58E-09 1.60E-10 7.64E-08 2906 CPC Pipe 7P97 2.14E-05 5.75E-05 2.57E-09 5.75E-08 2.44E-10 3.09E-06 1.08E-06 7.95E-07 6.02E-07 9.39E-06 7.57E-08 2.96E-08 1.40E-08 9.84E-11 1.10E-09 2.06E-11 9.82E-09 2731 HAC 144' Pipe 7P275 9.58E-06 3.52E-06 4.73E-10 1.19E-08 2.82E-10 5.03E-07 1.53E-07 1.15E-07 8.67E-08 1.51E-06 1.01E-07 7.90E-09 3.68E-09 1.72E-10 2.47E-09 9.20E-12 4.39E-09 2891 HC4 131' Pipe 14CH2178 3.21E-05 5.55E-05 0.00E+00 0.00E+00 5.81E-11 6.06E-05 3.13E-05 2.33E-05 1.81E-05 4.08E-04 0.00E+00 3.50E-16 2.69E-10 6.90E-14 0.00E+00 3.08E-11 1.47E-08 2893 HC4 131' Pipe 7CH22 3.21E-05 5.55E-05 0.00E+00 0.00E+00 5.81E-11 6.06E-05 3.13E-05 2.33E-05 1.81E-05 4.08E-04 0.00E+00 3.50E-16 2.69E-10 6.90E-14 0.00E+00 3.08E-11 1.47E-08 1565 Instrument Rm 114' Pipe 15V1064 VEC Vent Duct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2846 LWC 100' Pipe 4P609 5.24E-07 1.41E-06 6.29E-11 1.41E-09 5.98E-12 7.55E-08 2.64E-08 1.95E-08 1.47E-08 2.30E-07 1.85E-09 7.24E-10 3.44E-10 2.41E-12 2.70E-11 5.03E-13 2.40E-10 1547 LWC 100' Pipe 6P105 7.17E-03 1.92E-02 8.61E-07 1.92E-05 8.18E-08 1.03E-03 3.61E-04 2.66E-04 2.01E-04 3.14E-03 2.53E-05 9.90E-06 4.71E-06 3.30E-08 3.69E-07 6.89E-09 3.29E-06 1566 LXA 114' Pipe 13S133 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 1567 LXA 114' Pipe 13S134 2.87E-09 4.77E-09 1.75E-13 3.76E-12 4.08E-14 1.04E-08 3.53E-09 2.31E-09 1.76E-09 3.10E-08 1.65E-12 1.81E-11 8.76E-12 1.32E-11 3.45E-12 2.76E-15 1.32E-12 1568 LXA 114' Pipe 13S139 3.33E-08 5.54E-08 2.03E-12 4.37E-11 4.74E-13 1.20E-07 4.10E-08 2.68E-08 2.04E-08 3.60E-07 1.91E-11 2.10E-10 1.02E-10 1.54E-10 4.00E-11 3.20E-14 1.53E-11 1573 LXA 114' Pipe 14CH83 8.65E-06 1.44E-05 5.27E-10 1.13E-08 1.23E-10 3.12E-05 1.06E-05 6.95E-06 5.30E-06 9.34E-05 4.96E-09 5.45E-08 2.64E-08 3.99E-08 1.04E-08 8.30E-12 3.96E-09 2892 LXA 114' Pipe 15CH748 7.68E-06 2.82E-06 3.79E-10 9.52E-09 2.26E-10 4.03E-07 1.23E-07 9.22E-08 6.95E-08 1.21E-06 8.07E-08 6.33E-09 2.95E-09 1.37E-10 1.98E-09 7.37E-12 3.52E-09
WVDP-606 Rev. 1 Page 63 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1574 LXA 114' Pipe 15DW312 3.95E-07 6.55E-07 2.41E-11 5.17E-10 5.61E-12 1.43E-06 4.86E-07 3.17E-07 2.42E-07 4.26E-06 2.27E-10 2.49E-09 1.20E-09 1.82E-09 4.74E-10 3.79E-13 1.81E-10 1575 LXA 114' Pipe 15J1298 7.41E-07 1.23E-06 4.52E-11 9.70E-10 1.05E-11 2.67E-06 9.11E-07 5.95E-07 4.54E-07 8.00E-06 4.25E-10 4.67E-09 2.26E-09 3.41E-09 8.89E-10 7.11E-13 3.39E-10 1576 LXA 114' Pipe 15J1300 4.92E-07 8.18E-07 3.00E-11 6.45E-10 6.99E-12 1.78E-06 6.06E-07 3.96E-07 3.02E-07 5.32E-06 2.83E-10 3.10E-09 1.50E-09 2.27E-09 5.91E-10 4.73E-13 2.26E-10 1577 LXA 114' Pipe 15J1315 1.48E-06 2.46E-06 9.04E-11 1.94E-09 2.10E-11 5.35E-06 1.82E-06 1.19E-06 9.08E-07 1.60E-05 8.50E-10 9.33E-09 4.52E-09 6.83E-09 1.78E-09 1.42E-12 6.78E-10 1579 LXA 114' Pipe 15S724 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 1580 LXA 114' Pipe 15S725 2.16E-07 3.59E-07 1.32E-11 2.83E-10 3.07E-12 7.80E-07 2.66E-07 1.74E-07 1.33E-07 2.33E-06 1.24E-10 1.36E-09 6.59E-10 9.97E-10 2.59E-10 2.08E-13 9.90E-11 1786 LXA 114' Pipe 15V1064 VEC Vent Duct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1582 LXA 114' Pipe 4CW460 8.65E-07 1.44E-06 5.27E-11 1.13E-09 1.23E-11 3.12E-06 1.06E-06 6.95E-07 5.30E-07 9.34E-06 4.96E-10 5.45E-09 2.64E-09 3.99E-09 1.04E-09 8.30E-13 3.96E-10 1583 LXA 114' Pipe 4CW461 1.73E-06 2.87E-06 1.05E-10 2.27E-09 2.46E-11 6.24E-06 2.13E-06 1.39E-06 1.06E-06 1.87E-05 9.93E-10 1.09E-08 5.27E-09 7.97E-09 2.08E-09 1.66E-12 7.92E-10 1584 LXA 114' Pipe 4J472A 1.36E-07 2.26E-07 8.30E-12 1.78E-10 1.93E-12 4.91E-07 1.67E-07 1.09E-07 8.34E-08 1.47E-06 7.81E-11 8.57E-10 4.15E-10 6.27E-10 1.63E-10 1.31E-13 6.23E-11 1585 LXA 114' Pipe 4J472B 1.36E-07 2.26E-07 8.30E-12 1.78E-10 1.93E-12 4.91E-07 1.67E-07 1.09E-07 8.34E-08 1.47E-06 7.81E-11 8.57E-10 4.15E-10 6.27E-10 1.63E-10 1.31E-13 6.23E-11 1586 LXA 114' Pipe 4J472C 1.36E-07 2.26E-07 8.30E-12 1.78E-10 1.93E-12 4.91E-07 1.67E-07 1.09E-07 8.34E-08 1.47E-06 7.81E-11 8.57E-10 4.15E-10 6.27E-10 1.63E-10 1.31E-13 6.23E-11 1588 LXA 114' Pipe 4S464 5.56E-08 9.24E-08 3.39E-12 7.29E-11 7.90E-13 2.01E-07 6.84E-08 4.47E-08 3.41E-08 6.01E-07 3.19E-11 3.51E-10 1.70E-10 2.56E-10 6.68E-11 5.34E-14 2.55E-11 1589 LXA 114' Pipe 4S465 8.35E-08 1.39E-07 5.09E-12 1.09E-10 1.19E-12 3.01E-07 1.03E-07 6.71E-08 5.12E-08 9.01E-07 4.79E-11 5.26E-10 2.55E-10 3.85E-10 1.00E-10 8.01E-14 3.82E-11 1590 LXA 114' Pipe 4S466 1.56E-07 2.58E-07 9.49E-12 2.04E-10 2.21E-12 5.62E-07 1.91E-07 1.25E-07 9.54E-08 1.68E-06 8.93E-11 9.81E-10 4.75E-10 7.17E-10 1.87E-10 1.49E-13 7.13E-11 1591 LXA 114' Pipe 4S470 1.73E-06 2.87E-06 1.05E-10 2.27E-09 2.46E-11 6.24E-06 2.13E-06 1.39E-06 1.06E-06 1.87E-05 9.93E-10 1.09E-08 5.27E-09 7.97E-09 2.08E-09 1.66E-12 7.92E-10 1592 LXA 114' Pipe 4S471 4.32E-08 7.18E-08 2.64E-12 5.66E-11 6.14E-13 1.56E-07 5.32E-08 3.48E-08 2.65E-08 4.67E-07 2.48E-11 2.72E-10 1.32E-10 1.99E-10 5.19E-11 4.15E-14 1.98E-11 1598 LXA 114' Pipe 4S78 4.44E-07 7.36E-07 2.71E-11 5.81E-10 6.30E-12 1.60E-06 5.46E-07 3.57E-07 2.72E-07 4.79E-06 2.55E-10 2.79E-09 1.35E-09 2.05E-09 5.32E-10 4.26E-13 2.03E-10 1599 LXA 114' Pipe 4S84 5.45E-07 9.05E-07 3.33E-11 7.14E-10 7.74E-12 1.97E-06 6.70E-07 4.38E-07 3.34E-07 5.89E-06 3.13E-10 3.43E-09 1.66E-09 2.51E-09 6.54E-10 5.23E-13 2.50E-10 1600 LXA 114' Pipe 4S85 1.02E-06 1.69E-06 6.21E-11 1.33E-09 1.45E-11 3.68E-06 1.25E-06 8.19E-07 6.25E-07 1.10E-05 5.85E-10 6.42E-09 3.11E-09 4.70E-09 1.22E-09 9.78E-13 4.67E-10 1601 LXA 114' Pipe 4S90 5.45E-07 9.05E-07 3.33E-11 7.14E-10 7.74E-12 1.97E-06 6.70E-07 4.38E-07 3.34E-07 5.89E-06 3.13E-10 3.43E-09 1.66E-09 2.51E-09 6.54E-10 5.23E-13 2.50E-10 1602 LXA 114' Pipe 4UA468 9.29E-07 1.54E-06 5.66E-11 1.22E-09 1.32E-11 3.35E-06 1.14E-06 7.47E-07 5.69E-07 1.00E-05 5.33E-10 5.85E-09 2.83E-09 4.28E-09 1.11E-09 8.91E-13 4.25E-10 1603 LXA 114' Pipe 4UA502 3.71E-05 6.15E-05 2.26E-09 4.86E-08 5.26E-10 1.34E-04 4.56E-05 2.98E-05 2.27E-05 4.00E-04 2.13E-08 2.34E-07 1.13E-07 1.71E-07 4.45E-08 3.56E-11 1.70E-08 1604 LXA 114' Pipe 4UA82 6.88E-08 1.14E-07 4.20E-12 9.01E-11 9.77E-13 2.48E-07 8.46E-08 5.53E-08 4.22E-08 7.43E-07 3.95E-11 4.33E-10 2.10E-10 3.17E-10 8.26E-11 6.60E-14 3.15E-11 1605 LXA 114' Pipe 4UA83 4.44E-07 7.36E-07 2.71E-11 5.81E-10 6.30E-12 1.60E-06 5.46E-07 3.57E-07 2.72E-07 4.79E-06 2.55E-10 2.79E-09 1.35E-09 2.05E-09 5.32E-10 4.26E-13 2.03E-10 2808 LXA 114' Pipe 5P730 1.00E-05 3.68E-06 4.95E-10 1.24E-08 2.95E-10 5.26E-07 1.60E-07 1.20E-07 9.07E-08 1.58E-06 1.05E-07 8.26E-09 3.85E-09 1.79E-10 2.59E-09 9.62E-12 4.59E-09 2809 LXA 114' Pipe 5P735 2.17E-04 7.95E-05 1.07E-08 2.69E-07 6.37E-09 1.14E-05 3.46E-06 2.60E-06 1.96E-06 3.42E-05 2.27E-06 1.78E-07 8.31E-08 3.88E-09 5.59E-08 2.08E-10 9.92E-08 2810 LXA 114' Pipe 5UA522 1.81E-07 6.63E-08 8.93E-12 2.24E-10 5.31E-12 9.49E-09 2.89E-09 2.17E-09 1.64E-09 2.85E-08 1.90E-09 1.49E-10 6.94E-11 3.23E-12 4.66E-11 1.73E-13 8.28E-11 1609 LXA 114' Pipe 7DW117 1.09E-08 1.81E-08 6.65E-13 1.43E-11 1.55E-13 3.94E-08 1.34E-08 8.77E-09 6.68E-09 1.18E-07 6.26E-12 6.87E-11 3.33E-11 5.03E-11 1.31E-11 1.05E-14 4.99E-12 1611 LXA 114' Pipe 7J56A 1.24E-06 2.05E-06 7.54E-11 1.62E-09 1.76E-11 4.47E-06 1.52E-06 9.94E-07 7.58E-07 1.34E-05 7.10E-10 7.79E-09 3.77E-09 5.70E-09 1.48E-09 1.19E-12 5.66E-10 1612 LXA 114' Pipe 7J56B 3.71E-06 6.15E-06 2.26E-10 4.86E-09 5.26E-11 1.34E-05 4.56E-06 2.98E-06 2.27E-06 4.00E-05 2.13E-09 2.34E-08 1.13E-08 1.71E-08 4.45E-09 3.56E-12 1.70E-09 1613 LXA 114' Pipe 7J56C 3.71E-06 6.15E-06 2.26E-10 4.86E-09 5.26E-11 1.34E-05 4.56E-06 2.98E-06 2.27E-06 4.00E-05 2.13E-09 2.34E-08 1.13E-08 1.71E-08 4.45E-09 3.56E-12 1.70E-09 1614 LXA 114' Pipe 7S12 1.48E-07 2.46E-07 9.04E-12 1.94E-10 2.10E-12 5.35E-07 1.82E-07 1.19E-07 9.08E-08 1.60E-06 8.50E-11 9.33E-10 4.52E-10 6.83E-10 1.78E-10 1.42E-13 6.78E-11 1615 LXA 114' Pipe 7S144 1.61E-09 2.66E-09 9.79E-14 2.10E-12 2.28E-14 5.80E-09 1.97E-09 1.29E-09 9.84E-10 1.73E-08 9.21E-13 1.01E-11 4.90E-12 7.40E-12 1.93E-12 1.54E-15 7.35E-13 1617 LXA 114' Pipe 7S58 2.59E-06 4.31E-06 1.58E-10 3.40E-09 3.68E-11 9.36E-06 3.19E-06 2.09E-06 1.59E-06 2.80E-05 1.49E-09 1.63E-08 7.91E-09 1.20E-08 3.11E-09 2.49E-12 1.19E-09
WVDP-606 Rev. 1 Page 64 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1618 LXA 114' Pipe 7S61 1.16E-06 1.92E-06 7.06E-11 1.52E-09 1.64E-11 4.18E-06 1.42E-06 9.31E-07 7.10E-07 1.25E-05 6.65E-10 7.29E-09 3.53E-09 5.34E-09 1.39E-09 1.11E-12 5.30E-10 1620 LXA 114' Pipe 7SC107 9.89E-07 1.64E-06 6.03E-11 1.30E-09 1.40E-11 3.57E-06 1.22E-06 7.95E-07 6.06E-07 1.07E-05 5.68E-10 6.23E-09 3.02E-09 4.56E-09 1.19E-09 9.49E-13 4.53E-10 1621 LXA 114' Pipe 7UA52 8.65E-07 1.44E-06 5.27E-11 1.13E-09 1.23E-11 3.12E-06 1.06E-06 6.95E-07 5.30E-07 9.34E-06 4.96E-10 5.45E-09 2.64E-09 3.99E-09 1.04E-09 8.30E-13 3.96E-10 2805 MOA Level Pipe 1DW31 7.21E-06 2.65E-06 3.56E-10 8.94E-09 2.12E-10 3.79E-07 1.15E-07 8.66E-08 6.53E-08 1.14E-06 7.57E-08 5.94E-09 2.77E-09 1.29E-10 1.86E-09 6.92E-12 3.30E-09 2804 OGA 131' Pipe 7P275 7.15E-06 1.92E-05 8.58E-10 1.92E-08 8.15E-11 1.03E-06 3.59E-07 2.65E-07 2.01E-07 3.13E-06 2.52E-08 9.86E-09 4.68E-09 3.28E-11 3.67E-10 6.86E-12 3.27E-09 537 OGC Pipe 6P101-4 Overhead Pipe 2.04E-05 5.46E-05 2.45E-09 5.46E-08 2.32E-10 2.93E-06 1.03E-06 7.56E-07 5.73E-07 8.93E-06 7.19E-08 2.81E-08 1.33E-08 9.35E-11 1.05E-09 1.96E-11 9.33E-09 546 OGC Pipe 6P101-6 Overhead Pipe 3.83E-05 1.03E-04 4.60E-09 1.03E-07 4.37E-10 5.52E-06 1.93E-06 1.42E-06 1.08E-06 1.68E-05 1.35E-07 5.29E-08 2.51E-08 1.76E-10 1.97E-09 3.68E-11 1.75E-08 536 OGC Pipe 6P99 Overhead Pipe 7.99E-05 2.14E-04 9.59E-09 2.14E-07 9.11E-10 1.15E-05 4.02E-06 2.96E-06 2.24E-06 3.50E-05 2.82E-07 1.10E-07 5.23E-08 3.67E-10 4.11E-09 7.67E-11 3.66E-08 2726 PPC-N Pipe 6P685 6.29E-08 5.94E-07 8.80E-10 1.94E-08 7.23E-09 1.07E-05 3.09E-06 2.57E-06 1.96E-06 4.47E-05 5.11E-08 3.41E-08 1.63E-08 1.06E-09 1.65E-08 6.04E-14 2.88E-11 2728 PPC-N Pipe GBDrain 9.24E-08 8.74E-07 1.29E-09 2.86E-08 1.06E-08 1.57E-05 4.54E-06 3.77E-06 2.88E-06 6.57E-05 7.52E-08 5.02E-08 2.40E-08 1.56E-09 2.43E-08 8.87E-14 4.23E-11 2534 PPH Pipe 15V951 5.24E-08 1.80E-06 1.28E-09 2.67E-08 7.97E-08 2.09E-05 7.34E-06 9.07E-06 6.81E-06 6.50E-05 2.92E-07 1.21E-07 5.92E-08 6.60E-09 8.33E-09 5.03E-14 2.40E-11 2535 PPH Pipe Decon 1.31E-08 4.50E-07 3.21E-10 6.68E-09 1.99E-08 5.23E-06 1.84E-06 2.27E-06 1.71E-06 1.63E-05 7.31E-08 3.03E-08 1.48E-08 1.65E-09 2.09E-09 1.26E-14 6.01E-12 1139 PSC-2 114' Pipe Vacuum 5.61E-08 2.06E-08 2.77E-12 6.96E-11 1.65E-12 2.95E-09 8.98E-10 6.73E-10 5.08E-10 8.87E-09 5.89E-10 4.62E-11 2.15E-11 1.00E-12 1.45E-11 5.39E-14 2.57E-11 2532 Ram Equipment Room RER Pipe 15V1007 4.33E-05 1.59E-05 2.14E-09 5.37E-08 1.27E-09 2.27E-06 6.93E-07 5.20E-07 3.92E-07 6.84E-06 4.55E-07 3.57E-08 1.66E-08 7.75E-10 1.12E-08 4.16E-11 1.98E-08 2533 Ram Equipment Room RER Pipe 15WW871 1.49E-04 5.48E-05 7.37E-09 1.85E-07 4.39E-09 7.83E-06 2.39E-06 1.79E-06 1.35E-06 2.36E-05 1.57E-06 1.23E-07 5.73E-08 2.67E-09 3.85E-08 1.43E-10 6.83E-08 1882 Roof Pipe VEC VEC Roof Duct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1086 SSC 131' Pipe 15CH1153-1 Chemical Line Running Through Hot Cells 8.05E-05 4.25E-05 7.73E-09 1.63E-07 9.34E-10 6.86E-06 1.82E-06 1.33E-06 1.01E-06 1.71E-05 7.19E-09 5.28E-09 2.60E-09 5.13E-09 1.86E-09 7.73E-11 3.69E-08 2531 SSC 131' Pipe 15V1031 1.04E-01 5.49E-02 9.99E-06 2.11E-04 1.21E-06 8.87E-03 2.35E-03 1.72E-03 1.31E-03 2.22E-02 9.29E-06 6.83E-06 3.36E-06 6.63E-06 2.40E-06 9.99E-08 4.77E-05 1838 SSC 131' Pipe 15V1031 ANA Cell 10" Hastalloy 7.79E-02 8.11E-02 6.02E-07 2.40E-04 1.32E-03 1.85E-02 5.98E-03 3.81E-03 2.64E-03 5.53E-02 1.92E-04 6.53E-05 2.32E-05 1.57E-06 1.55E-06 7.48E-08 3.57E-05 2465 ULO 100' Pipe 15V1069 8.19E-03 3.01E-03 4.05E-07 1.02E-05 2.41E-07 4.30E-04 1.31E-04 9.83E-05 7.41E-05 1.29E-03 8.60E-05 6.75E-06 3.15E-06 1.47E-07 2.11E-06 7.87E-09 3.75E-06 2396 Uranium Product Cell (UPC)
Pipe 15V947 3.46E-07 3.30E-06 3.05E-11 5.96E-10 1.27E-09 1.22E-07 1.26E-07 6.30E-08 4.81E-08 1.45E-08 5.30E-09 2.46E-09 1.18E-09 1.89E-11 1.64E-10 3.32E-13 1.59E-10 2399 Uranium Product Cell (UPC)
Pipe 15V958 1.04E-07 9.96E-07 9.18E-12 1.80E-10 3.83E-10 3.66E-08 3.79E-08 1.90E-08 1.45E-08 4.37E-09 1.60E-09 7.41E-10 3.55E-10 5.71E-12 4.94E-11 1.00E-13 4.78E-11 2391 UWA 114' Pipe 15DW311 1.54E-05 5.64E-06 7.59E-10 1.90E-08 4.52E-10 8.07E-07 2.46E-07 1.84E-07 1.39E-07 2.43E-06 1.61E-07 1.27E-08 5.90E-09 2.75E-10 3.96E-09 1.47E-11 7.04E-09 2392 UWA 114' Pipe 15DW37 1.28E-06 4.70E-07 6.32E-11 1.59E-09 3.76E-11 6.72E-08 2.05E-08 1.54E-08 1.16E-08 2.02E-07 1.34E-08 1.05E-09 4.92E-10 2.29E-11 3.30E-10 1.23E-12 5.86E-10 2389 VEC 144' Pipe 7P275 1.28E-05 4.70E-06 6.32E-10 1.59E-08 3.76E-10 6.72E-07 2.05E-07 1.54E-07 1.16E-07 2.02E-06 1.34E-07 1.05E-08 4.92E-09 2.29E-10 3.30E-09 1.23E-11 5.86E-09 2382 VWR Pipe 15CH1203 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2383 VWR Pipe 15CH1205 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2380 VWR Pipe 15CH1208 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2384 VWR Pipe 15CH1209 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2385 VWR Pipe 15CH1210 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2386 VWR Pipe 15CH1211 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2387 VWR Pipe 15CH1212 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2388 VWR Pipe 15CH1213 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
WVDP-606 Rev. 1 Page 65 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2381 VWR Pipe 15CH748 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2379 VWR Pipe 15V1007 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1632 VWR Pipe 15V1007 FRS to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2374 VWR Pipe 15V1008 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1635 VWR Pipe 15V1008 Lab Hood to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2378 VWR Pipe 15V1031 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1633 VWR Pipe 15V1031 ANA Cell to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1787 VWR Pipe 15V1064 Main Vent Duct VWR to VEC 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2375 VWR Pipe 15V959 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1630 VWR Pipe 15V959 CPC Vent 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2376 VWR Pipe 15V960 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1631 VWR Pipe 15V960 PMC to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2377 VWR Pipe 15V961 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1638 VWR Pipe 15V961 Ex Cells to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1636 VWR Pipe 15V982 From ULO, PPH, PSC 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2373 VWR Pipe 15V983 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1640 VWR Pipe 15V983 RER Vent 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2371 VWR Pipe 15V985 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1634 VWR Pipe 15V985 COA to Washer 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2370 VWR Pipe 15V986 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1639 VWR Pipe 15V986 By-Pass Vent Duct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1376 XC-1 Pipe 13P189 1.23E-05 1.24E-05 5.41E-10 1.34E-08 8.28E-10 2.48E-06 5.49E-07 7.19E-07 5.49E-07 5.36E-06 7.70E-10 9.59E-10 4.65E-10 2.94E-10 1.00E-09 1.18E-11 5.63E-09 1377 XC-1 Pipe 13P189 9.85E-06 9.95E-06 4.33E-10 1.07E-08 6.64E-10 1.99E-06 4.40E-07 5.76E-07 4.40E-07 4.29E-06 6.18E-10 7.68E-10 3.72E-10 2.35E-10 8.05E-10 9.46E-12 4.51E-09 2253 XC-1 Pipe 13P189 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 2254 XC-1 Pipe 13P189 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1378 XC-1 Pipe 13P26 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 1379 XC-1 Pipe 13P26 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2255 XC-1 Pipe 13P26 3.27E-03 3.30E-03 1.44E-07 3.56E-06 2.20E-07 6.60E-04 1.46E-04 1.91E-04 1.46E-04 1.43E-03 2.05E-07 2.55E-07 1.24E-07 7.81E-08 2.67E-07 3.14E-09 1.50E-06 2256 XC-1 Pipe 13P26 3.27E-03 3.30E-03 1.44E-07 3.56E-06 2.20E-07 6.60E-04 1.46E-04 1.91E-04 1.46E-04 1.43E-03 2.05E-07 2.55E-07 1.24E-07 7.81E-08 2.67E-07 3.14E-09 1.50E-06 1380 XC-1 Pipe 15CH1153 2.62E-06 2.64E-06 1.15E-10 2.85E-09 1.76E-10 5.29E-07 1.17E-07 1.53E-07 1.17E-07 1.14E-06 1.64E-10 2.04E-10 9.89E-11 6.25E-11 2.14E-10 2.51E-12 1.20E-09 2257 XC-1 Pipe 15CH1153 2.29E-05 2.31E-05 1.01E-09 2.49E-08 1.54E-09 4.62E-06 1.02E-06 1.34E-06 1.02E-06 9.98E-06 1.43E-09 1.79E-09 8.65E-10 5.47E-10 1.87E-09 2.20E-11 1.05E-08 1381 XC-1 Pipe 15CH588 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 1382 XC-1 Pipe 15CH588 4.09E-06 4.13E-06 1.80E-10 4.46E-09 2.76E-10 8.26E-07 1.83E-07 2.39E-07 1.83E-07 1.78E-06 2.56E-10 3.19E-10 1.55E-10 9.77E-11 3.34E-10 3.93E-12 1.87E-09 2258 XC-1 Pipe 15CH588 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11
WVDP-606 Rev. 1 Page 66 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2259 XC-1 Pipe 15CH588 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 1383 XC-1 Pipe 15CH751 5.22E-06 5.28E-06 2.30E-10 5.69E-09 3.52E-10 1.06E-06 2.34E-07 3.06E-07 2.34E-07 2.28E-06 3.28E-10 4.07E-10 1.97E-10 1.25E-10 4.27E-10 5.01E-12 2.39E-09 2260 XC-1 Pipe 15CH751 5.22E-07 5.28E-07 2.30E-11 5.69E-10 3.52E-11 1.06E-07 2.34E-08 3.06E-08 2.34E-08 2.28E-07 3.28E-11 4.07E-11 1.97E-11 1.25E-11 4.27E-11 5.01E-13 2.39E-10 1384 XC-1 Pipe 15CH766 3.93E-06 3.96E-06 1.73E-10 4.28E-09 2.65E-10 7.93E-07 1.75E-07 2.30E-07 1.75E-07 1.71E-06 2.46E-10 3.06E-10 1.48E-10 9.38E-11 3.21E-10 3.77E-12 1.80E-09 1385 XC-1 Pipe 15CH766 1.97E-05 1.99E-05 8.67E-10 2.15E-08 1.33E-09 3.98E-06 8.81E-07 1.15E-06 8.81E-07 8.59E-06 1.24E-09 1.54E-09 7.45E-10 4.71E-10 1.61E-09 1.89E-11 9.02E-09 2261 XC-1 Pipe 15CH766 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 2262 XC-1 Pipe 15CH766 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1386 XC-1 Pipe 15CH767 9.80E-10 9.90E-10 4.31E-14 1.07E-12 6.61E-14 1.98E-10 4.38E-11 5.73E-11 4.38E-11 4.27E-10 6.15E-14 7.64E-14 3.70E-14 2.34E-14 8.01E-14 9.41E-16 4.49E-13 1387 XC-1 Pipe 15CH767 9.80E-10 9.90E-10 4.31E-14 1.07E-12 6.61E-14 1.98E-10 4.38E-11 5.73E-11 4.38E-11 4.27E-10 6.15E-14 7.64E-14 3.70E-14 2.34E-14 8.01E-14 9.41E-16 4.49E-13 2263 XC-1 Pipe 15CH767 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 2264 XC-1 Pipe 15CH767 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1388 XC-1 Pipe 15CH768 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 2265 XC-1 Pipe 15CH768 5.22E-07 5.28E-07 2.30E-11 5.69E-10 3.52E-11 1.06E-07 2.34E-08 3.06E-08 2.34E-08 2.28E-07 3.28E-11 4.07E-11 1.97E-11 1.25E-11 4.27E-11 5.01E-13 2.39E-10 2266 XC-1 Pipe 15P1355 6.22E-07 6.28E-07 2.74E-11 6.78E-10 4.19E-11 1.26E-07 2.78E-08 3.64E-08 2.78E-08 2.71E-07 3.90E-11 4.85E-11 2.35E-11 1.49E-11 5.08E-11 5.97E-13 2.85E-10 1389 XC-1 Pipe 15S724 4.91E-10 4.95E-10 2.16E-14 5.35E-13 3.31E-14 9.91E-11 2.19E-11 2.87E-11 2.19E-11 2.14E-10 3.08E-14 3.83E-14 1.85E-14 1.17E-14 4.01E-14 4.71E-16 2.25E-13 2267 XC-1 Pipe 15S724 1.96E-07 1.98E-07 8.62E-12 2.14E-10 1.32E-11 3.96E-08 8.76E-09 1.15E-08 8.76E-09 8.55E-08 1.23E-11 1.53E-11 7.41E-12 4.68E-12 1.60E-11 1.88E-13 8.98E-11 1390 XC-1 Pipe 15V1081 4.91E-05 4.95E-05 2.16E-09 5.35E-08 3.31E-09 9.91E-06 2.19E-06 2.87E-06 2.19E-06 2.14E-05 3.08E-09 3.83E-09 1.85E-09 1.17E-09 4.01E-09 4.71E-11 2.25E-08 2268 XC-1 Pipe 15V1081 2.35E-06 2.38E-06 1.04E-10 2.57E-09 1.59E-10 4.75E-07 1.05E-07 1.38E-07 1.05E-07 1.03E-06 1.48E-10 1.84E-10 8.90E-11 5.62E-11 1.92E-10 2.26E-12 1.08E-09 1391 XC-1 Pipe 15V1082 4.32E-06 4.36E-06 1.90E-10 4.71E-09 2.91E-10 8.72E-07 1.93E-07 2.53E-07 1.93E-07 1.88E-06 2.71E-10 3.37E-10 1.63E-10 1.03E-10 3.53E-10 4.15E-12 1.98E-09 2269 XC-1 Pipe 15V1082 2.35E-06 2.38E-06 1.04E-10 2.57E-09 1.59E-10 4.75E-07 1.05E-07 1.38E-07 1.05E-07 1.03E-06 1.48E-10 1.84E-10 8.90E-11 5.62E-11 1.92E-10 2.26E-12 1.08E-09 1392 XC-1 Pipe 15V1083 3.95E-05 3.98E-05 1.74E-09 4.30E-08 2.66E-09 7.97E-06 1.76E-06 2.31E-06 1.76E-06 1.72E-05 2.47E-09 3.08E-09 1.49E-09 9.43E-10 3.22E-09 3.79E-11 1.81E-08 2270 XC-1 Pipe 15V1083 2.35E-06 2.38E-06 1.04E-10 2.57E-09 1.59E-10 4.75E-07 1.05E-07 1.38E-07 1.05E-07 1.03E-06 1.48E-10 1.84E-10 8.90E-11 5.62E-11 1.92E-10 2.26E-12 1.08E-09 2271 XC-1 Pipe 15V955 1.04E-04 1.06E-04 4.60E-09 1.14E-07 7.04E-09 2.11E-05 4.67E-06 6.11E-06 4.67E-06 4.56E-05 6.55E-09 8.15E-09 3.95E-09 2.50E-09 8.54E-09 1.00E-10 4.79E-08 1394 XC-1 Pipe 3P120 1.31E-05 1.32E-05 5.76E-10 1.43E-08 8.82E-10 2.64E-06 5.85E-07 7.65E-07 5.85E-07 5.70E-06 8.20E-10 1.02E-09 4.95E-10 3.13E-10 1.07E-09 1.26E-11 5.99E-09 2272 XC-1 Pipe 3P120 1.31E-05 1.32E-05 5.76E-10 1.43E-08 8.82E-10 2.64E-06 5.85E-07 7.65E-07 5.85E-07 5.70E-06 8.20E-10 1.02E-09 4.95E-10 3.13E-10 1.07E-09 1.26E-11 5.99E-09 1395 XC-1 Pipe 3P84 5.22E-06 5.28E-06 2.30E-10 5.69E-09 3.52E-10 1.06E-06 2.34E-07 3.06E-07 2.34E-07 2.28E-06 3.28E-10 4.07E-10 1.97E-10 1.25E-10 4.27E-10 5.01E-12 2.39E-09 2273 XC-1 Pipe 3P84 4.58E-05 4.62E-05 2.01E-09 4.99E-08 3.08E-09 9.25E-06 2.05E-06 2.68E-06 2.05E-06 2.00E-05 2.87E-09 3.57E-09 1.73E-09 1.09E-09 3.74E-09 4.39E-11 2.10E-08 1396 XC-1 Pipe 4P125A 3.27E-10 3.30E-10 1.44E-14 3.56E-13 2.20E-14 6.60E-11 1.46E-11 1.91E-11 1.46E-11 1.43E-10 2.05E-14 2.55E-14 1.24E-14 7.81E-15 2.67E-14 3.14E-16 1.50E-13 2274 XC-1 Pipe 4P125A 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 1397 XC-1 Pipe 4P125B 2.74E-08 2.77E-08 1.21E-12 2.99E-11 1.85E-12 5.54E-09 1.23E-09 1.60E-09 1.23E-09 1.20E-08 1.72E-12 2.14E-12 1.04E-12 6.55E-13 2.24E-12 2.63E-14 1.26E-11 2275 XC-1 Pipe 4P125B 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1398 XC-1 Pipe 4P125C 8.16E-11 8.24E-11 3.59E-15 8.89E-14 5.50E-15 1.65E-11 3.65E-12 4.77E-12 3.65E-12 3.56E-11 5.12E-15 6.36E-15 3.08E-15 1.95E-15 6.67E-15 7.83E-17 3.74E-14 2276 XC-1 Pipe 4P125C 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1399 XC-1 Pipe 4P135A 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 1400 XC-1 Pipe 4P135A 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11
WVDP-606 Rev. 1 Page 67 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2277 XC-1 Pipe 4P135A 1.09E-08 1.10E-08 4.79E-13 1.19E-11 7.34E-13 2.20E-09 4.87E-10 6.37E-10 4.87E-10 4.75E-09 6.83E-13 8.50E-13 4.12E-13 2.60E-13 8.90E-13 1.05E-14 4.99E-12 2278 XC-1 Pipe 4P135A 1.09E-08 1.10E-08 4.79E-13 1.19E-11 7.34E-13 2.20E-09 4.87E-10 6.37E-10 4.87E-10 4.75E-09 6.83E-13 8.50E-13 4.12E-13 2.60E-13 8.90E-13 1.05E-14 4.99E-12 1401 XC-1 Pipe 4P135B 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 1402 XC-1 Pipe 4P135B 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 2279 XC-1 Pipe 4P135B 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 2280 XC-1 Pipe 4P135B 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 1403 XC-1 Pipe 4P135C 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 1404 XC-1 Pipe 4P135C 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 2281 XC-1 Pipe 4P135C 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 2282 XC-1 Pipe 4P135C 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 1405 XC-1 Pipe 4P177 3.29E-07 3.32E-07 1.45E-11 3.58E-10 2.22E-11 6.64E-08 1.47E-08 1.92E-08 1.47E-08 1.43E-07 2.06E-11 2.57E-11 1.24E-11 7.86E-12 2.69E-11 3.16E-13 1.51E-10 2283 XC-1 Pipe 4P177 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1406 XC-1 Pipe 4P185A 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 2284 XC-1 Pipe 4P185A 1.09E-08 1.10E-08 4.79E-13 1.19E-11 7.34E-13 2.20E-09 4.87E-10 6.37E-10 4.87E-10 4.75E-09 6.83E-13 8.50E-13 4.12E-13 2.60E-13 8.90E-13 1.05E-14 4.99E-12 1407 XC-1 Pipe 4P185B 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 2285 XC-1 Pipe 4P185B 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 1408 XC-1 Pipe 4P185C 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 2286 XC-1 Pipe 4P185C 2.73E-09 2.75E-09 1.20E-13 2.97E-12 1.84E-13 5.51E-10 1.22E-10 1.59E-10 1.22E-10 1.19E-09 1.71E-13 2.13E-13 1.03E-13 6.52E-14 2.23E-13 2.62E-15 1.25E-12 1409 XC-1 Pipe 4P19 3.29E-07 3.32E-07 1.45E-11 3.58E-10 2.22E-11 6.64E-08 1.47E-08 1.92E-08 1.47E-08 1.43E-07 2.06E-11 2.57E-11 1.24E-11 7.86E-12 2.69E-11 3.16E-13 1.51E-10 2287 XC-1 Pipe 4P19 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1410 XC-1 Pipe 4P25 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10 2288 XC-1 Pipe 4P25 3.27E-06 3.30E-06 1.44E-10 3.56E-09 2.20E-10 6.60E-07 1.46E-07 1.91E-07 1.46E-07 1.43E-06 2.05E-10 2.55E-10 1.24E-10 7.81E-11 2.67E-10 3.14E-12 1.50E-09 1411 XC-1 Pipe 4P28 9.80E-10 9.90E-10 4.31E-14 1.07E-12 6.61E-14 1.98E-10 4.38E-11 5.73E-11 4.38E-11 4.27E-10 6.15E-14 7.64E-14 3.70E-14 2.34E-14 8.01E-14 9.41E-16 4.49E-13 2289 XC-1 Pipe 4P28 4.91E-06 4.95E-06 2.16E-10 5.35E-09 3.31E-10 9.91E-07 2.19E-07 2.87E-07 2.19E-07 2.14E-06 3.08E-10 3.83E-10 1.85E-10 1.17E-10 4.01E-10 4.71E-12 2.25E-09 1412 XC-1 Pipe 4P3 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10 2290 XC-1 Pipe 4P3 2.29E-05 2.31E-05 1.01E-09 2.49E-08 1.54E-09 4.62E-06 1.02E-06 1.34E-06 1.02E-06 9.98E-06 1.43E-09 1.79E-09 8.65E-10 5.47E-10 1.87E-09 2.20E-11 1.05E-08 1413 XC-1 Pipe 4P32 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 1414 XC-1 Pipe 4P32 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 2291 XC-1 Pipe 4P32 4.38E-06 4.43E-06 1.93E-10 4.78E-09 2.95E-10 8.85E-07 1.96E-07 2.56E-07 1.96E-07 1.91E-06 2.75E-10 3.42E-10 1.66E-10 1.05E-10 3.58E-10 4.21E-12 2.01E-09 2292 XC-1 Pipe 4P32 4.38E-06 4.43E-06 1.93E-10 4.78E-09 2.95E-10 8.85E-07 1.96E-07 2.56E-07 1.96E-07 1.91E-06 2.75E-10 3.42E-10 1.66E-10 1.05E-10 3.58E-10 4.21E-12 2.01E-09 1415 XC-1 Pipe 4P329A 1.96E-06 1.98E-06 8.62E-11 2.14E-09 1.32E-10 3.96E-07 8.76E-08 1.15E-07 8.76E-08 8.55E-07 1.23E-10 1.53E-10 7.41E-11 4.68E-11 1.60E-10 1.88E-12 8.98E-10 1416 XC-1 Pipe 4P329A 8.16E-06 8.24E-06 3.59E-10 8.89E-09 5.50E-10 1.65E-06 3.65E-07 4.77E-07 3.65E-07 3.56E-06 5.12E-10 6.36E-10 3.08E-10 1.95E-10 6.67E-10 7.83E-12 3.74E-09 2293 XC-1 Pipe 4P329A 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 2294 XC-1 Pipe 4P329A 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 1417 XC-1 Pipe 4P329B 1.23E-06 1.24E-06 5.41E-11 1.34E-09 8.28E-11 2.48E-07 5.49E-08 7.19E-08 5.49E-08 5.36E-07 7.70E-11 9.59E-11 4.65E-11 2.94E-11 1.00E-10 1.18E-12 5.63E-10
WVDP-606 Rev. 1 Page 68 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1418 XC-1 Pipe 4P329B 4.78E-07 4.83E-07 2.10E-11 5.21E-10 3.22E-11 9.66E-08 2.14E-08 2.80E-08 2.14E-08 2.08E-07 3.00E-11 3.73E-11 1.81E-11 1.14E-11 3.91E-11 4.59E-13 2.19E-10 2295 XC-1 Pipe 4P329B 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 2296 XC-1 Pipe 4P329B 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 1419 XC-1 Pipe 4P329C 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 1420 XC-1 Pipe 4P329C 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2297 XC-1 Pipe 4P329C 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 2298 XC-1 Pipe 4P329C 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 1421 XC-1 Pipe 4P33 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10 2299 XC-1 Pipe 4P33 2.29E-05 2.31E-05 1.01E-09 2.49E-08 1.54E-09 4.62E-06 1.02E-06 1.34E-06 1.02E-06 9.98E-06 1.43E-09 1.79E-09 8.65E-10 5.47E-10 1.87E-09 2.20E-11 1.05E-08 1422 XC-1 Pipe 4P34 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10 2300 XC-1 Pipe 4P34 2.29E-05 2.31E-05 1.01E-09 2.49E-08 1.54E-09 4.62E-06 1.02E-06 1.34E-06 1.02E-06 9.98E-06 1.43E-09 1.79E-09 8.65E-10 5.47E-10 1.87E-09 2.20E-11 1.05E-08 1423 XC-1 Pipe 4P355 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 2301 XC-1 Pipe 4P355 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 1424 XC-1 Pipe 4P398A 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 2302 XC-1 Pipe 4P398A 1.64E-08 1.65E-08 7.20E-13 1.78E-11 1.10E-12 3.31E-09 7.32E-10 9.58E-10 7.32E-10 7.14E-09 1.03E-12 1.28E-12 6.19E-13 3.91E-13 1.34E-12 1.57E-14 7.50E-12 1425 XC-1 Pipe 4P398B 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 1426 XC-1 Pipe 4P398B 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 2303 XC-1 Pipe 4P398B 4.09E-09 4.13E-09 1.80E-13 4.46E-12 2.76E-13 8.26E-10 1.83E-10 2.39E-10 1.83E-10 1.78E-09 2.56E-13 3.19E-13 1.55E-13 9.77E-14 3.34E-13 3.93E-15 1.87E-12 2304 XC-1 Pipe 4P398B 4.09E-09 4.13E-09 1.80E-13 4.46E-12 2.76E-13 8.26E-10 1.83E-10 2.39E-10 1.83E-10 1.78E-09 2.56E-13 3.19E-13 1.55E-13 9.77E-14 3.34E-13 3.93E-15 1.87E-12 1427 XC-1 Pipe 4P398C 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10 1428 XC-1 Pipe 4P398C 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10 2305 XC-1 Pipe 4P398C 4.09E-09 4.13E-09 1.80E-13 4.46E-12 2.76E-13 8.26E-10 1.83E-10 2.39E-10 1.83E-10 1.78E-09 2.56E-13 3.19E-13 1.55E-13 9.77E-14 3.34E-13 3.93E-15 1.87E-12 2306 XC-1 Pipe 4P398C 4.09E-09 4.13E-09 1.80E-13 4.46E-12 2.76E-13 8.26E-10 1.83E-10 2.39E-10 1.83E-10 1.78E-09 2.56E-13 3.19E-13 1.55E-13 9.77E-14 3.34E-13 3.93E-15 1.87E-12 1429 XC-1 Pipe 4P4 2.45E-07 2.48E-07 1.08E-11 2.67E-10 1.65E-11 4.95E-08 1.10E-08 1.43E-08 1.10E-08 1.07E-07 1.54E-11 1.91E-11 9.27E-12 5.86E-12 2.00E-11 2.35E-13 1.12E-10 2307 XC-1 Pipe 4P4 1.72E-05 1.73E-05 7.55E-10 1.87E-08 1.16E-09 3.47E-06 7.67E-07 1.00E-06 7.67E-07 7.48E-06 1.08E-09 1.34E-09 6.49E-10 4.10E-10 1.40E-09 1.65E-11 7.86E-09 1430 XC-1 Pipe 4P42 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2308 XC-1 Pipe 4P42 2.18E-08 2.20E-08 9.59E-13 2.38E-11 1.47E-12 4.40E-09 9.74E-10 1.27E-09 9.74E-10 9.50E-09 1.37E-12 1.70E-12 8.24E-13 5.21E-13 1.78E-12 2.09E-14 9.98E-12 1431 XC-1 Pipe 4P432A 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 1432 XC-1 Pipe 4P432A 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 2309 XC-1 Pipe 4P432A 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 2310 XC-1 Pipe 4P432A 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 1433 XC-1 Pipe 4P432B 2.04E-04 2.07E-04 9.00E-09 2.23E-07 1.38E-08 4.13E-05 9.14E-06 1.20E-05 9.14E-06 8.92E-05 1.28E-08 1.59E-08 7.73E-09 4.89E-09 1.67E-08 1.96E-10 9.37E-08 2311 XC-1 Pipe 4P432B 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12 1434 XC-1 Pipe 4P432C 6.12E-08 6.18E-08 2.69E-12 6.67E-11 4.12E-12 1.24E-08 2.74E-09 3.58E-09 2.74E-09 2.67E-08 3.84E-12 4.77E-12 2.31E-12 1.46E-12 5.00E-12 5.87E-14 2.80E-11 2312 XC-1 Pipe 4P432C 2.04E-08 2.07E-08 9.00E-13 2.23E-11 1.38E-12 4.13E-09 9.14E-10 1.20E-09 9.14E-10 8.92E-09 1.28E-12 1.59E-12 7.73E-13 4.89E-13 1.67E-12 1.96E-14 9.37E-12
WVDP-606 Rev. 1 Page 69 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1435 XC-1 Pipe 4P448A 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 2313 XC-1 Pipe 4P448A 1.14E-05 1.16E-05 5.03E-10 1.25E-08 7.71E-10 2.31E-06 5.11E-07 6.69E-07 5.11E-07 4.99E-06 7.17E-10 8.93E-10 4.33E-10 2.73E-10 9.35E-10 1.10E-11 5.24E-09 1436 XC-1 Pipe 4P448B 5.47E-08 5.53E-08 2.41E-12 5.97E-11 3.69E-12 1.11E-08 2.45E-09 3.20E-09 2.45E-09 2.39E-08 3.43E-12 4.27E-12 2.07E-12 1.31E-12 4.47E-12 5.25E-14 2.51E-11 2314 XC-1 Pipe 4P448B 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 1437 XC-1 Pipe 4P448C 8.21E-08 8.29E-08 3.61E-12 8.95E-11 5.53E-12 1.66E-08 3.67E-09 4.80E-09 3.67E-09 3.58E-08 5.15E-12 6.40E-12 3.10E-12 1.96E-12 6.71E-12 7.88E-14 3.76E-11 2315 XC-1 Pipe 4P448C 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 1438 XC-1 Pipe 4P5 1.64E-06 1.66E-06 7.22E-11 1.79E-09 1.11E-10 3.32E-07 7.34E-08 9.60E-08 7.34E-08 7.16E-07 1.03E-10 1.28E-10 6.21E-11 3.92E-11 1.34E-10 1.58E-12 7.52E-10 2316 XC-1 Pipe 4P5 1.72E-05 1.73E-05 7.55E-10 1.87E-08 1.16E-09 3.47E-06 7.67E-07 1.00E-06 7.67E-07 7.48E-06 1.08E-09 1.34E-09 6.49E-10 4.10E-10 1.40E-09 1.65E-11 7.86E-09 1439 XC-1 Pipe 4P52 2.45E-07 2.48E-07 1.08E-11 2.67E-10 1.65E-11 4.95E-08 1.10E-08 1.43E-08 1.10E-08 1.07E-07 1.54E-11 1.91E-11 9.27E-12 5.86E-12 2.00E-11 2.35E-13 1.12E-10 2317 XC-1 Pipe 4P52 1.23E-07 1.24E-07 5.41E-12 1.34E-10 8.28E-12 2.48E-08 5.49E-09 7.19E-09 5.49E-09 5.36E-08 7.70E-12 9.59E-12 4.65E-12 2.94E-12 1.00E-11 1.18E-13 5.63E-11 1440 XC-1 Pipe 4P537 6.52E-09 6.58E-09 2.87E-13 7.10E-12 4.39E-13 1.32E-09 2.91E-10 3.81E-10 2.91E-10 2.84E-09 4.09E-13 5.08E-13 2.46E-13 1.56E-13 5.32E-13 6.26E-15 2.98E-12 2318 XC-1 Pipe 4P537 5.22E-06 5.28E-06 2.30E-10 5.69E-09 3.52E-10 1.06E-06 2.34E-07 3.06E-07 2.34E-07 2.28E-06 3.28E-10 4.07E-10 1.97E-10 1.25E-10 4.27E-10 5.01E-12 2.39E-09 1441 XC-1 Pipe 4P63 1.96E-05 1.98E-05 8.62E-10 2.14E-08 1.32E-09 3.96E-06 8.76E-07 1.15E-06 8.76E-07 8.55E-06 1.23E-09 1.53E-09 7.41E-10 4.68E-10 1.60E-09 1.88E-11 8.98E-09 2319 XC-1 Pipe 4P63 3.27E-08 3.31E-08 1.44E-12 3.57E-11 2.21E-12 6.61E-09 1.46E-09 1.92E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.82E-13 2.67E-12 3.14E-14 1.50E-11 1442 XC-1 Pipe 4P648 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2320 XC-1 Pipe 4P648 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1443 XC-1 Pipe 4P649 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2321 XC-1 Pipe 4P649 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1444 XC-1 Pipe 4P652 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 2322 XC-1 Pipe 4P652 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1445 XC-1 Pipe 4P653 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 2323 XC-1 Pipe 4P653 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1446 XC-1 Pipe 4P656 6.52E-10 6.58E-10 2.87E-14 7.10E-13 4.39E-14 1.32E-10 2.91E-11 3.81E-11 2.91E-11 2.84E-10 4.09E-14 5.08E-14 2.46E-14 1.56E-14 5.32E-14 6.26E-16 2.98E-13 2324 XC-1 Pipe 4P656 1.47E-07 1.49E-07 6.48E-12 1.61E-10 9.93E-12 2.97E-08 6.58E-09 8.61E-09 6.58E-09 6.42E-08 9.23E-12 1.15E-11 5.57E-12 3.52E-12 1.20E-11 1.41E-13 6.74E-11 1447 XC-1 Pipe 4P657 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 2325 XC-1 Pipe 4P657 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1448 XC-1 Pipe 4P663 1.31E-09 1.32E-09 5.76E-14 1.43E-12 8.82E-14 2.64E-10 5.85E-11 7.65E-11 5.85E-11 5.70E-10 8.20E-14 1.02E-13 4.95E-14 3.13E-14 1.07E-13 1.26E-15 5.99E-13 2326 XC-1 Pipe 4P663 2.95E-07 2.97E-07 1.30E-11 3.21E-10 1.99E-11 5.95E-08 1.32E-08 1.72E-08 1.32E-08 1.28E-07 1.85E-11 2.30E-11 1.11E-11 7.04E-12 2.41E-11 2.83E-13 1.35E-10 1449 XC-1 Pipe 4P664 2.16E-07 2.18E-07 9.50E-12 2.35E-10 1.46E-11 4.36E-08 9.65E-09 1.26E-08 9.65E-09 9.41E-08 1.35E-11 1.68E-11 8.16E-12 5.16E-12 1.76E-11 2.07E-13 9.89E-11 2327 XC-1 Pipe 4P664 7.36E-07 7.44E-07 3.24E-11 8.03E-10 4.96E-11 1.49E-07 3.29E-08 4.31E-08 3.29E-08 3.21E-07 4.62E-11 5.74E-11 2.78E-11 1.76E-11 6.02E-11 7.07E-13 3.37E-10 1450 XC-1 Pipe 4P665 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10 2328 XC-1 Pipe 4P665 1.47E-07 1.49E-07 6.48E-12 1.61E-10 9.93E-12 2.97E-08 6.58E-09 8.61E-09 6.58E-09 6.42E-08 9.23E-12 1.15E-11 5.57E-12 3.52E-12 1.20E-11 1.41E-13 6.74E-11 1451 XC-1 Pipe 4P667 5.22E-07 5.28E-07 2.30E-11 5.69E-10 3.52E-11 1.06E-07 2.34E-08 3.06E-08 2.34E-08 2.28E-07 3.28E-11 4.07E-11 1.97E-11 1.25E-11 4.27E-11 5.01E-13 2.39E-10 2329 XC-1 Pipe 4P667 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 1452 XC-1 Pipe 4P71 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10
WVDP-606 Rev. 1 Page 70 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2330 XC-1 Pipe 4P71 2.45E-06 2.48E-06 1.08E-10 2.67E-09 1.65E-10 4.95E-07 1.10E-07 1.43E-07 1.10E-07 1.07E-06 1.54E-10 1.91E-10 9.27E-11 5.86E-11 2.00E-10 2.35E-12 1.12E-09 1453 XC-1 Pipe 4P81B 8.16E-08 8.24E-08 3.59E-12 8.89E-11 5.50E-12 1.65E-08 3.65E-09 4.77E-09 3.65E-09 3.56E-08 5.12E-12 6.36E-12 3.08E-12 1.95E-12 6.67E-12 7.83E-14 3.74E-11 2331 XC-1 Pipe 4P81B 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1454 XC-1 Pipe 4P81C 4.09E-08 4.13E-08 1.80E-12 4.46E-11 2.76E-12 8.26E-09 1.83E-09 2.39E-09 1.83E-09 1.78E-08 2.56E-12 3.19E-12 1.55E-12 9.77E-13 3.34E-12 3.93E-14 1.87E-11 2332 XC-1 Pipe 4P81C 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1455 XC-1 Pipe 4P92 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10 2333 XC-1 Pipe 4P92 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1456 XC-1 Pipe 4S119 2.45E-07 2.48E-07 1.08E-11 2.67E-10 1.65E-11 4.95E-08 1.10E-08 1.43E-08 1.10E-08 1.07E-07 1.54E-11 1.91E-11 9.27E-12 5.86E-12 2.00E-11 2.35E-13 1.12E-10 2334 XC-1 Pipe 4S119 1.96E-07 1.98E-07 8.62E-12 2.14E-10 1.32E-11 3.96E-08 8.76E-09 1.15E-08 8.76E-09 8.55E-08 1.23E-11 1.53E-11 7.41E-12 4.68E-12 1.60E-11 1.88E-13 8.98E-11 1457 XC-1 Pipe 4S421 1.31E-06 1.33E-06 5.78E-11 1.43E-09 8.85E-11 2.65E-07 5.87E-08 7.68E-08 5.87E-08 5.73E-07 8.24E-11 1.02E-10 4.96E-11 3.14E-11 1.07E-10 1.26E-12 6.02E-10 2335 XC-1 Pipe 4S421 1.23E-07 1.24E-07 5.41E-12 1.34E-10 8.28E-12 2.48E-08 5.49E-09 7.19E-09 5.49E-09 5.36E-08 7.70E-12 9.59E-12 4.65E-12 2.94E-12 1.00E-11 1.18E-13 5.63E-11 1458 XC-1 Pipe 4S425 1.23E-06 1.24E-06 5.41E-11 1.34E-09 8.28E-11 2.48E-07 5.49E-08 7.19E-08 5.49E-08 5.36E-07 7.70E-11 9.59E-11 4.65E-11 2.94E-11 1.00E-10 1.18E-12 5.63E-10 2336 XC-1 Pipe 4S425 1.23E-07 1.24E-07 5.41E-12 1.34E-10 8.28E-12 2.48E-08 5.49E-09 7.19E-09 5.49E-09 5.36E-08 7.70E-12 9.59E-12 4.65E-12 2.94E-12 1.00E-11 1.18E-13 5.63E-11 1459 XC-1 Pipe 4S514 1.64E-07 1.65E-07 7.20E-12 1.78E-10 1.10E-11 3.31E-08 7.32E-09 9.58E-09 7.32E-09 7.14E-08 1.03E-11 1.28E-11 6.19E-12 3.91E-12 1.34E-11 1.57E-13 7.50E-11 2337 XC-1 Pipe 4S514 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 1460 XC-1 Pipe 4S78 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10 2338 XC-1 Pipe 4S78 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1461 XC-1 Pipe 4S80 4.91E-07 4.95E-07 2.16E-11 5.35E-10 3.31E-11 9.91E-08 2.19E-08 2.87E-08 2.19E-08 2.14E-07 3.08E-11 3.83E-11 1.85E-11 1.17E-11 4.01E-11 4.71E-13 2.25E-10 2339 XC-1 Pipe 4S80 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1462 XC-1 Pipe 4S84 7.86E-07 7.94E-07 3.46E-11 8.57E-10 5.30E-11 1.59E-07 3.51E-08 4.60E-08 3.51E-08 3.43E-07 4.93E-11 6.13E-11 2.97E-11 1.88E-11 6.42E-11 7.55E-13 3.60E-10 2340 XC-1 Pipe 4S84 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1463 XC-1 Pipe 4S85 3.29E-06 3.32E-06 1.45E-10 3.58E-09 2.22E-10 6.64E-07 1.47E-07 1.92E-07 1.47E-07 1.43E-06 2.06E-10 2.57E-10 1.24E-10 7.86E-11 2.69E-10 3.16E-12 1.51E-09 2341 XC-1 Pipe 4S85 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1464 XC-1 Pipe 4S90 3.93E-06 3.96E-06 1.73E-10 4.28E-09 2.65E-10 7.93E-07 1.75E-07 2.30E-07 1.75E-07 1.71E-06 2.46E-10 3.06E-10 1.48E-10 9.38E-11 3.21E-10 3.77E-12 1.80E-09 2342 XC-1 Pipe 4S90 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1465 XC-1 Pipe 4UA82 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 2343 XC-1 Pipe 4UA82 6.07E-08 6.13E-08 2.67E-12 6.62E-11 4.09E-12 1.23E-08 2.71E-09 3.55E-09 2.71E-09 2.65E-08 3.81E-12 4.73E-12 2.29E-12 1.45E-12 4.96E-12 5.83E-14 2.78E-11 1466 XC-1 Pipe 5P199 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 1467 XC-1 Pipe 5P199 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 2344 XC-1 Pipe 5P199 1.75E-06 1.77E-06 7.71E-11 1.91E-09 1.18E-10 3.54E-07 7.83E-08 1.02E-07 7.83E-08 7.64E-07 1.10E-10 1.37E-10 6.62E-11 4.19E-11 1.43E-10 1.68E-12 8.02E-10 2345 XC-1 Pipe 5P199 1.75E-06 1.77E-06 7.71E-11 1.91E-09 1.18E-10 3.54E-07 7.83E-08 1.02E-07 7.83E-08 7.64E-07 1.10E-10 1.37E-10 6.62E-11 4.19E-11 1.43E-10 1.68E-12 8.02E-10 1468 XC-1 Pipe 5P392 4.93E-06 4.98E-06 2.17E-10 5.37E-09 3.32E-10 9.96E-07 2.20E-07 2.88E-07 2.20E-07 2.15E-06 3.09E-10 3.85E-10 1.86E-10 1.18E-10 4.03E-10 4.73E-12 2.26E-09 2346 XC-1 Pipe 5P392 1.64E-08 1.65E-08 7.20E-13 1.78E-11 1.10E-12 3.31E-09 7.32E-10 9.58E-10 7.32E-10 7.14E-09 1.03E-12 1.28E-12 6.19E-13 3.91E-13 1.34E-12 1.57E-14 7.50E-12 1469 XC-1 Pipe 5P519 2.74E-08 2.77E-08 1.21E-12 2.99E-11 1.85E-12 5.54E-09 1.23E-09 1.60E-09 1.23E-09 1.20E-08 1.72E-12 2.14E-12 1.04E-12 6.55E-13 2.24E-12 2.63E-14 1.26E-11 1470 XC-1 Pipe 5P519 2.19E-07 2.21E-07 9.63E-12 2.39E-10 1.48E-11 4.42E-08 9.79E-09 1.28E-08 9.79E-09 9.54E-08 1.37E-11 1.71E-11 8.27E-12 5.23E-12 1.79E-11 2.10E-13 1.00E-10
WVDP-606 Rev. 1 Page 71 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2347 XC-1 Pipe 5P519 4.11E-08 4.15E-08 1.81E-12 4.48E-11 2.77E-12 8.30E-09 1.84E-09 2.40E-09 1.84E-09 1.79E-08 2.58E-12 3.21E-12 1.55E-12 9.82E-13 3.36E-12 3.95E-14 1.88E-11 2348 XC-1 Pipe 5P519 3.29E-07 3.32E-07 1.45E-11 3.58E-10 2.22E-11 6.64E-08 1.47E-08 1.92E-08 1.47E-08 1.43E-07 2.06E-11 2.57E-11 1.24E-11 7.86E-12 2.69E-11 3.16E-13 1.51E-10 1471 XC-1 Pipe 6P100 3.93E-09 3.96E-09 1.73E-13 4.28E-12 2.65E-13 7.93E-10 1.75E-10 2.30E-10 1.75E-10 1.71E-09 2.46E-13 3.06E-13 1.48E-13 9.38E-14 3.21E-13 3.77E-15 1.80E-12 1472 XC-1 Pipe 6P100 3.93E-09 3.96E-09 1.73E-13 4.28E-12 2.65E-13 7.93E-10 1.75E-10 2.30E-10 1.75E-10 1.71E-09 2.46E-13 3.06E-13 1.48E-13 9.38E-14 3.21E-13 3.77E-15 1.80E-12 2349 XC-1 Pipe 6P100 5.12E-04 5.18E-04 2.25E-08 5.59E-07 3.45E-08 1.04E-04 2.29E-05 3.00E-05 2.29E-05 2.23E-04 3.21E-08 4.00E-08 1.94E-08 1.22E-08 4.19E-08 4.92E-10 2.35E-07 2350 XC-1 Pipe 6P100 5.12E-04 5.18E-04 2.25E-08 5.59E-07 3.45E-08 1.04E-04 2.29E-05 3.00E-05 2.29E-05 2.23E-04 3.21E-08 4.00E-08 1.94E-08 1.22E-08 4.19E-08 4.92E-10 2.35E-07 1473 XC-1 Pipe 6P105 3.93E-09 3.96E-09 1.73E-13 4.28E-12 2.65E-13 7.93E-10 1.75E-10 2.30E-10 1.75E-10 1.71E-09 2.46E-13 3.06E-13 1.48E-13 9.38E-14 3.21E-13 3.77E-15 1.80E-12 2351 XC-1 Pipe 6P105 1.31E-02 1.33E-02 5.78E-07 1.43E-05 8.85E-07 2.65E-03 5.87E-04 7.68E-04 5.87E-04 5.73E-03 8.24E-07 1.02E-06 4.96E-07 3.14E-07 1.07E-06 1.26E-08 6.02E-06 1474 XC-1 Pipe 6P54A 3.27E-10 3.30E-10 1.44E-14 3.56E-13 2.20E-14 6.60E-11 1.46E-11 1.91E-11 1.46E-11 1.43E-10 2.05E-14 2.55E-14 1.24E-14 7.81E-15 2.67E-14 3.14E-16 1.50E-13 1475 XC-1 Pipe 6P54A 1.09E-07 1.11E-07 4.82E-12 1.19E-10 7.38E-12 2.21E-08 4.89E-09 6.40E-09 4.89E-09 4.77E-08 6.86E-12 8.54E-12 4.14E-12 2.62E-12 8.94E-12 1.05E-13 5.01E-11 2352 XC-1 Pipe 6P54A 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 2353 XC-1 Pipe 6P54A 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 1476 XC-1 Pipe 6P54B 2.74E-08 2.77E-08 1.21E-12 2.99E-11 1.85E-12 5.54E-09 1.23E-09 1.60E-09 1.23E-09 1.20E-08 1.72E-12 2.14E-12 1.04E-12 6.55E-13 2.24E-12 2.63E-14 1.26E-11 1477 XC-1 Pipe 6P54B 2.74E-08 2.77E-08 1.21E-12 2.99E-11 1.85E-12 5.54E-09 1.23E-09 1.60E-09 1.23E-09 1.20E-08 1.72E-12 2.14E-12 1.04E-12 6.55E-13 2.24E-12 2.63E-14 1.26E-11 2354 XC-1 Pipe 6P54B 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 2355 XC-1 Pipe 6P54B 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1478 XC-1 Pipe 6P54C 2.74E-08 2.77E-08 1.21E-12 2.99E-11 1.85E-12 5.54E-09 1.23E-09 1.60E-09 1.23E-09 1.20E-08 1.72E-12 2.14E-12 1.04E-12 6.55E-13 2.24E-12 2.63E-14 1.26E-11 1479 XC-1 Pipe 6P54C 3.27E-07 3.30E-07 1.44E-11 3.56E-10 2.20E-11 6.60E-08 1.46E-08 1.91E-08 1.46E-08 1.43E-07 2.05E-11 2.55E-11 1.24E-11 7.81E-12 2.67E-11 3.14E-13 1.50E-10 2356 XC-1 Pipe 6P54C 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 2357 XC-1 Pipe 6P54C 3.27E-08 3.30E-08 1.44E-12 3.56E-11 2.20E-12 6.60E-09 1.46E-09 1.91E-09 1.46E-09 1.43E-08 2.05E-12 2.55E-12 1.24E-12 7.81E-13 2.67E-12 3.14E-14 1.50E-11 1480 XC-1 Pipe 6P8A 1.64E-08 1.65E-08 7.20E-13 1.78E-11 1.10E-12 3.31E-09 7.32E-10 9.58E-10 7.32E-10 7.14E-09 1.03E-12 1.28E-12 6.19E-13 3.91E-13 1.34E-12 1.57E-14 7.50E-12 1481 XC-1 Pipe 6P8A 6.52E-07 6.58E-07 2.87E-11 7.10E-10 4.39E-11 1.32E-07 2.91E-08 3.81E-08 2.91E-08 2.84E-07 4.09E-11 5.08E-11 2.46E-11 1.56E-11 5.32E-11 6.26E-13 2.98E-10 2358 XC-1 Pipe 6P8A 1.14E-05 1.16E-05 5.03E-10 1.25E-08 7.71E-10 2.31E-06 5.11E-07 6.69E-07 5.11E-07 4.99E-06 7.17E-10 8.93E-10 4.33E-10 2.73E-10 9.35E-10 1.10E-11 5.24E-09 2359 XC-1 Pipe 6P8A 1.14E-05 1.16E-05 5.03E-10 1.25E-08 7.71E-10 2.31E-06 5.11E-07 6.69E-07 5.11E-07 4.99E-06 7.17E-10 8.93E-10 4.33E-10 2.73E-10 9.35E-10 1.10E-11 5.24E-09 1482 XC-1 Pipe 6P8B 2.45E-08 2.48E-08 1.08E-12 2.67E-11 1.65E-12 4.95E-09 1.10E-09 1.43E-09 1.10E-09 1.07E-08 1.54E-12 1.91E-12 9.27E-13 5.86E-13 2.00E-12 2.35E-14 1.12E-11 1483 XC-1 Pipe 6P8B 6.52E-04 6.58E-04 2.87E-08 7.10E-07 4.39E-08 1.32E-04 2.91E-05 3.81E-05 2.91E-05 2.84E-04 4.09E-08 5.08E-08 2.46E-08 1.56E-08 5.32E-08 6.26E-10 2.98E-07 2360 XC-1 Pipe 6P8B 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 2361 XC-1 Pipe 6P8B 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 1484 XC-1 Pipe 6P8C 8.16E-11 8.24E-11 3.59E-15 8.89E-14 5.50E-15 1.65E-11 3.65E-12 4.77E-12 3.65E-12 3.56E-11 5.12E-15 6.36E-15 3.08E-15 1.95E-15 6.67E-15 7.83E-17 3.74E-14 1485 XC-1 Pipe 6P8C 8.16E-11 8.24E-11 3.59E-15 8.89E-14 5.50E-15 1.65E-11 3.65E-12 4.77E-12 3.65E-12 3.56E-11 5.12E-15 6.36E-15 3.08E-15 1.95E-15 6.67E-15 7.83E-17 3.74E-14 2362 XC-1 Pipe 6P8C 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 2363 XC-1 Pipe 6P8C 2.86E-06 2.89E-06 1.26E-10 3.12E-09 1.93E-10 5.78E-07 1.28E-07 1.67E-07 1.28E-07 1.25E-06 1.79E-10 2.23E-10 1.08E-10 6.84E-11 2.34E-10 2.75E-12 1.31E-09 1486 XC-1 Pipe 7P191 6.57E-07 6.63E-07 2.89E-11 7.16E-10 4.43E-11 1.33E-07 2.94E-08 3.84E-08 2.94E-08 2.86E-07 4.12E-11 5.12E-11 2.48E-11 1.57E-11 5.37E-11 6.30E-13 3.01E-10 2364 XC-1 Pipe 7P191 4.41E-06 4.46E-06 1.94E-10 4.81E-09 2.97E-10 8.91E-07 1.97E-07 2.58E-07 1.97E-07 1.92E-06 2.77E-10 3.44E-10 1.67E-10 1.05E-10 3.61E-10 4.24E-12 2.02E-09 1487 XC-1 Pipe 7P34 3.93E-06 3.96E-06 1.73E-10 4.28E-09 2.65E-10 7.93E-07 1.75E-07 2.30E-07 1.75E-07 1.71E-06 2.46E-10 3.06E-10 1.48E-10 9.38E-11 3.21E-10 3.77E-12 1.80E-09
WVDP-606 Rev. 1 Page 72 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2365 XC-1 Pipe 7P34 1.47E-06 1.49E-06 6.48E-11 1.61E-09 9.93E-11 2.97E-07 6.58E-08 8.61E-08 6.58E-08 6.42E-07 9.23E-11 1.15E-10 5.57E-11 3.52E-11 1.20E-10 1.41E-12 6.74E-10 1488 XC-1 Pipe 7P44 5.22E-06 5.28E-06 2.30E-10 5.69E-09 3.52E-10 1.06E-06 2.34E-07 3.06E-07 2.34E-07 2.28E-06 3.28E-10 4.07E-10 1.97E-10 1.25E-10 4.27E-10 5.01E-12 2.39E-09 2366 XC-1 Pipe 7P44 5.22E-07 5.28E-07 2.30E-11 5.69E-10 3.52E-11 1.06E-07 2.34E-08 3.06E-08 2.34E-08 2.28E-07 3.28E-11 4.07E-11 1.97E-11 1.25E-11 4.27E-11 5.01E-13 2.39E-10 1489 XC-1 Pipe 7P45 3.29E-07 3.32E-07 1.45E-11 3.58E-10 2.22E-11 6.64E-08 1.47E-08 1.92E-08 1.47E-08 1.43E-07 2.06E-11 2.57E-11 1.24E-11 7.86E-12 2.69E-11 3.16E-13 1.51E-10 2367 XC-1 Pipe 7P45 3.93E-07 3.96E-07 1.73E-11 4.28E-10 2.65E-11 7.93E-08 1.75E-08 2.30E-08 1.75E-08 1.71E-07 2.46E-11 3.06E-11 1.48E-11 9.38E-12 3.21E-11 3.77E-13 1.80E-10 1490 XC-1 Pipe 7S42 1.31E-06 1.32E-06 5.76E-11 1.43E-09 8.82E-11 2.64E-07 5.85E-08 7.65E-08 5.85E-08 5.70E-07 8.20E-11 1.02E-10 4.95E-11 3.13E-11 1.07E-10 1.26E-12 5.99E-10 2368 XC-1 Pipe 7S42 1.31E-07 1.32E-07 5.76E-12 1.43E-10 8.82E-12 2.64E-08 5.85E-09 7.65E-09 5.85E-09 5.70E-08 8.20E-12 1.02E-11 4.95E-12 3.13E-12 1.07E-11 1.26E-13 5.99E-11 1212 XC-2 Pipe 13J123A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2094 XC-2 Pipe 13J123A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1213 XC-2 Pipe 13J123B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2095 XC-2 Pipe 13J123B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1214 XC-2 Pipe 13J123C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2096 XC-2 Pipe 13J123C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1215 XC-2 Pipe 13J184B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2097 XC-2 Pipe 13J184B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1216 XC-2 Pipe 13J184C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2098 XC-2 Pipe 13J184C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1217 XC-2 Pipe 13J185C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2099 XC-2 Pipe 13J185C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1218 XC-2 Pipe 13J238C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2100 XC-2 Pipe 13J238C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1219 XC-2 Pipe 13J69A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2101 XC-2 Pipe 13J69A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1220 XC-2 Pipe 13J69B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2102 XC-2 Pipe 13J69B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1221 XC-2 Pipe 13J69C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2103 XC-2 Pipe 13J69C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1223 XC-2 Pipe 13P14 1.98E-05 3.28E-05 1.21E-09 2.59E-08 2.81E-10 7.14E-05 2.43E-05 1.59E-05 1.21E-05 2.14E-04 1.14E-08 1.25E-07 6.03E-08 9.12E-08 2.37E-08 1.90E-11 9.06E-09 2105 XC-2 Pipe 13P14 1.98E-05 3.28E-05 1.21E-09 2.59E-08 2.81E-10 7.14E-05 2.43E-05 1.59E-05 1.21E-05 2.14E-04 1.14E-08 1.25E-07 6.03E-08 9.12E-08 2.37E-08 1.90E-11 9.06E-09 1224 XC-2 Pipe 13P15 1.49E-05 2.47E-05 9.08E-10 1.95E-08 2.11E-10 5.37E-05 1.83E-05 1.20E-05 9.13E-06 1.61E-04 8.55E-09 9.38E-08 4.54E-08 6.86E-08 1.79E-08 1.43E-11 6.82E-09 2106 XC-2 Pipe 13P15 1.49E-05 2.47E-05 9.08E-10 1.95E-08 2.11E-10 5.37E-05 1.83E-05 1.20E-05 9.13E-06 1.61E-04 8.55E-09 9.38E-08 4.54E-08 6.86E-08 1.79E-08 1.43E-11 6.82E-09 1225 XC-2 Pipe 13P178 4.92E-06 8.18E-06 3.00E-10 6.45E-09 6.99E-11 1.78E-05 6.06E-06 3.96E-06 3.02E-06 5.32E-05 2.83E-09 3.10E-08 1.50E-08 2.27E-08 5.91E-09 4.73E-12 2.26E-09 2107 XC-2 Pipe 13P178 4.92E-06 8.18E-06 3.00E-10 6.45E-09 6.99E-11 1.78E-05 6.06E-06 3.96E-06 3.02E-06 5.32E-05 2.83E-09 3.10E-08 1.50E-08 2.27E-08 5.91E-09 4.73E-12 2.26E-09 1238 XC-2 Pipe 13P237 3.95E-06 6.55E-06 2.41E-10 5.17E-09 5.61E-11 1.43E-05 4.86E-06 3.17E-06 2.42E-06 4.26E-05 2.27E-09 2.49E-08 1.20E-08 1.82E-08 4.74E-09 3.79E-12 1.81E-09 2120 XC-2 Pipe 13P237 3.95E-06 6.55E-06 2.41E-10 5.17E-09 5.61E-11 1.43E-05 4.86E-06 3.17E-06 2.42E-06 4.26E-05 2.27E-09 2.49E-08 1.20E-08 1.82E-08 4.74E-09 3.79E-12 1.81E-09
WVDP-606 Rev. 1 Page 73 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1242 XC-2 Pipe 13P255 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 2124 XC-2 Pipe 13P255 2.47E-07 4.10E-07 1.51E-11 3.24E-10 3.51E-12 8.92E-07 3.04E-07 1.99E-07 1.51E-07 2.67E-06 1.42E-10 1.56E-09 7.53E-10 1.14E-09 2.96E-10 2.37E-13 1.13E-10 1245 XC-2 Pipe 13P4 7.41E-07 1.23E-06 4.52E-11 9.70E-10 1.05E-11 2.67E-06 9.11E-07 5.95E-07 4.54E-07 8.00E-06 4.25E-10 4.67E-09 2.26E-09 3.41E-09 8.89E-10 7.11E-13 3.39E-10 2127 XC-2 Pipe 13P4 7.41E-07 1.23E-06 4.52E-11 9.70E-10 1.05E-11 2.67E-06 9.11E-07 5.95E-07 4.54E-07 8.00E-06 4.25E-10 4.67E-09 2.26E-09 3.41E-09 8.89E-10 7.11E-13 3.39E-10 1247 XC-2 Pipe 13P43 3.98E-06 6.62E-06 2.43E-10 5.22E-09 5.66E-11 1.44E-05 4.90E-06 3.20E-06 2.44E-06 4.30E-05 2.29E-09 2.51E-08 1.22E-08 1.84E-08 4.78E-09 3.83E-12 1.83E-09 2129 XC-2 Pipe 13P43 3.98E-06 6.62E-06 2.43E-10 5.22E-09 5.66E-11 1.44E-05 4.90E-06 3.20E-06 2.44E-06 4.30E-05 2.29E-09 2.51E-08 1.22E-08 1.84E-08 4.78E-09 3.83E-12 1.83E-09 1248 XC-2 Pipe 13P45 2.47E-06 4.10E-06 1.51E-10 3.24E-09 3.51E-11 8.92E-06 3.04E-06 1.99E-06 1.51E-06 2.67E-05 1.42E-09 1.56E-08 7.53E-09 1.14E-08 2.96E-09 2.37E-12 1.13E-09 2130 XC-2 Pipe 13P45 2.47E-06 4.10E-06 1.51E-10 3.24E-09 3.51E-11 8.92E-06 3.04E-06 1.99E-06 1.51E-06 2.67E-05 1.42E-09 1.56E-08 7.53E-09 1.14E-08 2.96E-09 2.37E-12 1.13E-09 1249 XC-2 Pipe 13P5 1.24E-05 2.05E-05 7.54E-10 1.62E-08 1.76E-10 4.47E-05 1.52E-05 9.94E-06 7.58E-06 1.34E-04 7.10E-09 7.79E-08 3.77E-08 5.70E-08 1.48E-08 1.19E-11 5.66E-09 2131 XC-2 Pipe 13P5 1.24E-05 2.05E-05 7.54E-10 1.62E-08 1.76E-10 4.47E-05 1.52E-05 9.94E-06 7.58E-06 1.34E-04 7.10E-09 7.79E-08 3.77E-08 5.70E-08 1.48E-08 1.19E-11 5.66E-09 1251 XC-2 Pipe 13P56 1.24E-05 2.05E-05 7.54E-10 1.62E-08 1.76E-10 4.47E-05 1.52E-05 9.94E-06 7.58E-06 1.34E-04 7.10E-09 7.79E-08 3.77E-08 5.70E-08 1.48E-08 1.19E-11 5.66E-09 2133 XC-2 Pipe 13P56 1.24E-05 2.05E-05 7.54E-10 1.62E-08 1.76E-10 4.47E-05 1.52E-05 9.94E-06 7.58E-06 1.34E-04 7.10E-09 7.79E-08 3.77E-08 5.70E-08 1.48E-08 1.19E-11 5.66E-09 1253 XC-2 Pipe 13P78 1.98E-06 3.28E-06 1.21E-10 2.59E-09 2.81E-11 7.14E-06 2.43E-06 1.59E-06 1.21E-06 2.14E-05 1.14E-09 1.25E-08 6.03E-09 9.12E-09 2.37E-09 1.90E-12 9.06E-10 2135 XC-2 Pipe 13P78 1.98E-06 3.28E-06 1.21E-10 2.59E-09 2.81E-11 7.14E-06 2.43E-06 1.59E-06 1.21E-06 2.14E-05 1.14E-09 1.25E-08 6.03E-09 9.12E-09 2.37E-09 1.90E-12 9.06E-10 1262 XC-2 Pipe 15CH630 4.92E-10 8.18E-10 3.00E-14 6.45E-13 6.99E-15 1.78E-09 6.06E-10 3.96E-10 3.02E-10 5.32E-09 2.83E-13 3.10E-12 1.50E-12 2.27E-12 5.91E-13 4.73E-16 2.26E-13 2144 XC-2 Pipe 15CH630 3.11E-09 5.17E-09 1.90E-13 4.08E-12 4.42E-14 1.12E-08 3.83E-09 2.50E-09 1.91E-09 3.36E-08 1.79E-12 1.96E-11 9.49E-12 1.43E-11 3.74E-12 2.99E-15 1.43E-12 1265 XC-2 Pipe 15J1300 4.92E-07 8.18E-07 3.00E-11 6.45E-10 6.99E-12 1.78E-06 6.06E-07 3.96E-07 3.02E-07 5.32E-06 2.83E-10 3.10E-09 1.50E-09 2.27E-09 5.91E-10 4.73E-13 2.26E-10 2147 XC-2 Pipe 15J1300 4.92E-07 8.18E-07 3.00E-11 6.45E-10 6.99E-12 1.78E-06 6.06E-07 3.96E-07 3.02E-07 5.32E-06 2.83E-10 3.10E-09 1.50E-09 2.27E-09 5.91E-10 4.73E-13 2.26E-10 1266 XC-2 Pipe 15J1369 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2148 XC-2 Pipe 15J1369 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1267 XC-2 Pipe 15J1370 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2149 XC-2 Pipe 15J1370 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1268 XC-2 Pipe 15J1396 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2150 XC-2 Pipe 15J1396 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1269 XC-2 Pipe 15J1397 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2151 XC-2 Pipe 15J1397 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1270 XC-2 Pipe 15J1398 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2152 XC-2 Pipe 15J1398 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1271 XC-2 Pipe 15J786 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2153 XC-2 Pipe 15J786 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1272 XC-2 Pipe 15J935 9.89E-08 1.64E-07 6.03E-12 1.30E-10 1.40E-12 3.57E-07 1.22E-07 7.95E-08 6.06E-08 1.07E-06 5.68E-11 6.23E-10 3.02E-10 4.56E-10 1.19E-10 9.49E-14 4.53E-11 2154 XC-2 Pipe 15J935 9.89E-08 1.64E-07 6.03E-12 1.30E-10 1.40E-12 3.57E-07 1.22E-07 7.95E-08 6.06E-08 1.07E-06 5.68E-11 6.23E-10 3.02E-10 4.56E-10 1.19E-10 9.49E-14 4.53E-11 1273 XC-2 Pipe 15P1351 1.24E-06 2.06E-06 7.57E-11 1.63E-09 1.76E-11 4.48E-06 1.53E-06 9.97E-07 7.60E-07 1.34E-05 7.12E-10 7.82E-09 3.78E-09 5.72E-09 1.49E-09 1.19E-12 5.68E-10 2155 XC-2 Pipe 15P1351 1.24E-06 2.06E-06 7.57E-11 1.63E-09 1.76E-11 4.48E-06 1.53E-06 9.97E-07 7.60E-07 1.34E-05 7.12E-10 7.82E-09 3.78E-09 5.72E-09 1.49E-09 1.19E-12 5.68E-10 1275 XC-2 Pipe 15P1367 4.92E-10 8.18E-10 3.00E-14 6.45E-13 6.99E-15 1.78E-09 6.06E-10 3.96E-10 3.02E-10 5.32E-09 2.83E-13 3.10E-12 1.50E-12 2.27E-12 5.91E-13 4.73E-16 2.26E-13
WVDP-606 Rev. 1 Page 74 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2157 XC-2 Pipe 15P1367 3.11E-09 5.17E-09 1.90E-13 4.08E-12 4.42E-14 1.12E-08 3.83E-09 2.50E-09 1.91E-09 3.36E-08 1.79E-12 1.96E-11 9.49E-12 1.43E-11 3.74E-12 2.99E-15 1.43E-12 1280 XC-2 Pipe 15P1394 1.98E-06 3.28E-06 1.21E-10 2.59E-09 2.81E-11 7.14E-06 2.43E-06 1.59E-06 1.21E-06 2.14E-05 1.14E-09 1.25E-08 6.03E-09 9.12E-09 2.37E-09 1.90E-12 9.06E-10 2162 XC-2 Pipe 15P1394 1.98E-06 3.28E-06 1.21E-10 2.59E-09 2.81E-11 7.14E-06 2.43E-06 1.59E-06 1.21E-06 2.14E-05 1.14E-09 1.25E-08 6.03E-09 9.12E-09 2.37E-09 1.90E-12 9.06E-10 1281 XC-2 Pipe 15P1395 9.89E-07 1.64E-06 6.03E-11 1.30E-09 1.40E-11 3.57E-06 1.22E-06 7.95E-07 6.06E-07 1.07E-05 5.68E-10 6.23E-09 3.02E-09 4.56E-09 1.19E-09 9.49E-13 4.53E-10 2163 XC-2 Pipe 15P1395 9.89E-07 1.64E-06 6.03E-11 1.30E-09 1.40E-11 3.57E-06 1.22E-06 7.95E-07 6.06E-07 1.07E-05 5.68E-10 6.23E-09 3.02E-09 4.56E-09 1.19E-09 9.49E-13 4.53E-10 1293 XC-2 Pipe 15S725 1.85E-07 3.08E-07 1.13E-11 2.43E-10 2.63E-12 6.69E-07 2.28E-07 1.49E-07 1.14E-07 2.00E-06 1.06E-10 1.17E-09 5.65E-10 8.54E-10 2.22E-10 1.78E-13 8.49E-11 2175 XC-2 Pipe 15S725 1.85E-07 3.08E-07 1.13E-11 2.43E-10 2.63E-12 6.69E-07 2.28E-07 1.49E-07 1.14E-07 2.00E-06 1.06E-10 1.17E-09 5.65E-10 8.54E-10 2.22E-10 1.78E-13 8.49E-11 2183 XC-2 Pipe 15V956 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1302 XC-2 Pipe 4CW129 7.41E-10 1.23E-09 4.52E-14 9.70E-13 1.05E-14 2.67E-09 9.11E-10 5.95E-10 4.54E-10 8.00E-09 4.25E-13 4.67E-12 2.26E-12 3.41E-12 8.89E-13 7.11E-16 3.39E-13 2184 XC-2 Pipe 4CW129 4.66E-09 7.74E-09 2.84E-13 6.11E-12 6.62E-14 1.68E-08 5.73E-09 3.75E-09 2.86E-09 5.03E-08 2.68E-12 2.94E-11 1.42E-11 2.15E-11 5.59E-12 4.48E-15 2.14E-12 1303 XC-2 Pipe 4CW130 7.41E-10 1.23E-09 4.52E-14 9.70E-13 1.05E-14 2.67E-09 9.11E-10 5.95E-10 4.54E-10 8.00E-09 4.25E-13 4.67E-12 2.26E-12 3.41E-12 8.89E-13 7.11E-16 3.39E-13 2185 XC-2 Pipe 4CW130 4.66E-09 7.74E-09 2.84E-13 6.11E-12 6.62E-14 1.68E-08 5.73E-09 3.75E-09 2.86E-09 5.03E-08 2.68E-12 2.94E-11 1.42E-11 2.15E-11 5.59E-12 4.48E-15 2.14E-12 1304 XC-2 Pipe 4IA391 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2186 XC-2 Pipe 4IA391 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1305 XC-2 Pipe 4J235A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2187 XC-2 Pipe 4J235A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1306 XC-2 Pipe 4J235B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2188 XC-2 Pipe 4J235B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1307 XC-2 Pipe 4J235C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2189 XC-2 Pipe 4J235C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1308 XC-2 Pipe 4J238B 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2190 XC-2 Pipe 4J238B 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1309 XC-2 Pipe 4J238C 1.24E-10 2.05E-10 7.54E-15 1.62E-13 1.76E-15 4.47E-10 1.52E-10 9.94E-11 7.58E-11 1.34E-09 7.10E-14 7.79E-13 3.77E-13 5.70E-13 1.48E-13 1.19E-16 5.66E-14 2191 XC-2 Pipe 4J238C 1.24E-10 2.05E-10 7.54E-15 1.62E-13 1.76E-15 4.47E-10 1.52E-10 9.94E-11 7.58E-11 1.34E-09 7.10E-14 7.79E-13 3.77E-13 5.70E-13 1.48E-13 1.19E-16 5.66E-14 1310 XC-2 Pipe 4J239 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2192 XC-2 Pipe 4J239 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1311 XC-2 Pipe 4J240 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 2193 XC-2 Pipe 4J240 6.17E-11 1.02E-10 3.76E-15 8.08E-14 8.75E-16 2.23E-10 7.58E-11 4.96E-11 3.78E-11 6.66E-10 3.54E-14 3.88E-13 1.88E-13 2.84E-13 7.40E-14 5.92E-17 2.82E-14 1312 XC-2 Pipe 4J246 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2194 XC-2 Pipe 4J246 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1313 XC-2 Pipe 4J247 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2195 XC-2 Pipe 4J247 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1314 XC-2 Pipe 4J323A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2196 XC-2 Pipe 4J323A 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1315 XC-2 Pipe 4J323B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11
WVDP-606 Rev. 1 Page 75 of 76 Mechanical Shearing Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 2197 XC-2 Pipe 4J323B 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1316 XC-2 Pipe 4J323C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2198 XC-2 Pipe 4J323C 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 1326 XC-2 Pipe 4P168 9.89E-10 1.64E-09 6.03E-14 1.30E-12 1.40E-14 3.57E-09 1.22E-09 7.95E-10 6.06E-10 1.07E-08 5.68E-13 6.23E-12 3.02E-12 4.56E-12 1.19E-12 9.49E-16 4.53E-13 2208 XC-2 Pipe 4P168 8.61E-09 1.43E-08 5.25E-13 1.13E-11 1.22E-13 3.11E-08 1.06E-08 6.92E-09 5.28E-09 9.30E-08 4.94E-12 5.42E-11 2.63E-11 3.97E-11 1.03E-11 8.26E-15 3.94E-12 1335 XC-2 Pipe 4P303 3.26E-07 5.42E-07 1.99E-11 4.27E-10 4.63E-12 1.18E-06 4.01E-07 2.62E-07 2.00E-07 3.52E-06 1.87E-10 2.06E-09 9.95E-10 1.50E-09 3.92E-10 3.13E-13 1.49E-10 2217 XC-2 Pipe 4P303 3.26E-07 5.42E-07 1.99E-11 4.27E-10 4.63E-12 1.18E-06 4.01E-07 2.62E-07 2.00E-07 3.52E-06 1.87E-10 2.06E-09 9.95E-10 1.50E-09 3.92E-10 3.13E-13 1.49E-10 2219 XC-2 Pipe 4P32 3.31E-06 5.50E-06 2.02E-10 4.34E-09 4.70E-11 1.20E-05 4.07E-06 2.66E-06 2.03E-06 3.58E-05 1.90E-09 2.09E-08 1.01E-08 1.53E-08 3.97E-09 3.18E-12 1.52E-09 1347 XC-2 Pipe 4P389 2.47E-09 4.10E-09 1.51E-13 3.24E-12 3.51E-14 8.92E-09 3.04E-09 1.99E-09 1.51E-09 2.67E-08 1.42E-12 1.56E-11 7.53E-12 1.14E-11 2.96E-12 2.37E-15 1.13E-12 2229 XC-2 Pipe 4P389 2.47E-09 4.10E-09 1.51E-13 3.24E-12 3.51E-14 8.92E-09 3.04E-09 1.99E-09 1.51E-09 2.67E-08 1.42E-12 1.56E-11 7.53E-12 1.14E-11 2.96E-12 2.37E-15 1.13E-12 1352 XC-2 Pipe 4P412 2.47E-09 4.10E-09 1.51E-13 3.24E-12 3.51E-14 8.92E-09 3.04E-09 1.99E-09 1.51E-09 2.67E-08 1.42E-12 1.56E-11 7.53E-12 1.14E-11 2.96E-12 2.37E-15 1.13E-12 2234 XC-2 Pipe 4P412 2.47E-09 4.10E-09 1.51E-13 3.24E-12 3.51E-14 8.92E-09 3.04E-09 1.99E-09 1.51E-09 2.67E-08 1.42E-12 1.56E-11 7.53E-12 1.14E-11 2.96E-12 2.37E-15 1.13E-12 1356 XC-2 Pipe 4S136 3.71E-10 6.15E-10 2.26E-14 4.86E-13 5.26E-15 1.34E-09 4.56E-10 2.98E-10 2.27E-10 4.00E-09 2.13E-13 2.34E-12 1.13E-12 1.71E-12 4.45E-13 3.56E-16 1.70E-13 2238 XC-2 Pipe 4S136 3.71E-10 6.15E-10 2.26E-14 4.86E-13 5.26E-15 1.34E-09 4.56E-10 2.98E-10 2.27E-10 4.00E-09 2.13E-13 2.34E-12 1.13E-12 1.71E-12 4.45E-13 3.56E-16 1.70E-13 1357 XC-2 Pipe 4S187 2.47E-10 4.10E-10 1.51E-14 3.24E-13 3.51E-15 8.92E-10 3.04E-10 1.99E-10 1.51E-10 2.67E-09 1.42E-13 1.56E-12 7.53E-13 1.14E-12 2.96E-13 2.37E-16 1.13E-13 2239 XC-2 Pipe 4S187 2.47E-10 4.10E-10 1.51E-14 3.24E-13 3.51E-15 8.92E-10 3.04E-10 1.99E-10 1.51E-10 2.67E-09 1.42E-13 1.56E-12 7.53E-13 1.14E-12 2.96E-13 2.37E-16 1.13E-13 1361 XC-2 Pipe 4S408 2.47E-10 4.10E-10 1.51E-14 3.24E-13 3.51E-15 8.92E-10 3.04E-10 1.99E-10 1.51E-10 2.67E-09 1.42E-13 1.56E-12 7.53E-13 1.14E-12 2.96E-13 2.37E-16 1.13E-13 2243 XC-2 Pipe 4S408 8.57E-08 1.42E-07 5.23E-12 1.12E-10 1.22E-12 3.09E-07 1.05E-07 6.89E-08 5.25E-08 9.26E-07 4.92E-11 5.40E-10 2.61E-10 3.95E-10 1.03E-10 8.23E-14 3.93E-11 1368 XC-2 Pipe 6J109 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11 2250 XC-2 Pipe 6J109 6.17E-08 1.02E-07 3.76E-12 8.08E-11 8.75E-13 2.23E-07 7.58E-08 4.96E-08 3.78E-08 6.66E-07 3.54E-11 3.88E-10 1.88E-10 2.84E-10 7.40E-11 5.92E-14 2.82E-11
WVDP-606 Rev. 1 Page 76 of 76 Concrete Saw Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci) 1562 OGC N Wall Corner 1.74E+01 4.67E+01 2.09E-03 4.67E-02 1.99E-04 2.51E+00 8.76E-01 6.46E-01 4.89E-01 7.63E+00 6.15E-02 2.40E-02 1.14E-02 8.00E-05 8.95E-04 1.672E-05 7.978E-03 Hot Cutting Characterization Database ID Area Structure Cs-137 (Ci)
Sr-90 (Ci)
Cm-243 (Ci)
Cm-244 (Ci)
Np-237 (Ci)
Am-241 (Ci)
Pu-238 (Ci)
Pu-239 (Ci)
Pu-240 (Ci)
Pu-241 (Ci)
U-232 (Ci)
U-233 (Ci)
U-234 (Ci)
U-235 (Ci)
U-238 (Ci)
I-129 (Ci)
Tc-99 (Ci)
Note 1 CPC Shield Wall 2.29E-04 6.14E-04 2.75E-08 6.14E-07 2.61E-09 3.30E-05 1.15E-05 8.49E-06 6.43E-06 1.00E-04 8.08E-07 3.16E-07 1.50E-07 1.05E-09 1.18E-08 2.20E-10 1.05E-07 Note1: This area is not in the June 20, 2020 Characterization database. Values are based on CPC scaling factors and radiological survey data provided in a 12/01/20 email Lowes to Blunt
WVDP-606 Rev. 1 WV-1807, Rev. 10 (DCIP-101) i WVDP RECORD OF REVISION Revision On Rev. No.
Description of Changes Page(s)
Dated 0
Original Issue; based upon BC-RP-0118, Rev. 4, All 03/30/2021 authored by Brent Blunt under subcontract to CHBWV.
This document affects the Regulatory Strategy and Facility Disposition Departments directly and all WVDP departments indirectly.
1 General Revision.
All 04/20/2021 Minor editorial revision to remove reference to BC-RP-0118.
2 This document affects the Regulatory Strategy and Facility Disposition Departments directly and all WVDP departments indirectly.
Ms. Marlayna Doell April 27, 2021 WVDP-607, Air Dispersion Modeling for Open-Air Demolition, Main Plant Process Building
West Valley Demonstration Project Doc. ID Number WVDP-607 Revision Number 1
Revision Date 04/20/2021 AIR DISPERSION MODELING FOR OPEN-AIR DEMOLITION MAIN PLANT PROCESS BUILDING Cognizant Author:
D. Biela Cognizant Manager:
J. F. Wood CH2M HILL BWXT West Valley, LLC 10282 Rock Springs Road West Valley, New York USA 14171-9799 WV-1816, Rev. 8 VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE
WVDP-607 Rev. 1 Page 2 of 28 WEST VALLEY DEMONSTRATION PROJECT MAIN PLANT PROCESS BUILDING Air Dispersion Modeling For Open Air Demolition
WVDP-607 Rev. 1 Page 3 of 28 3
Introduction The Main Plant Process Building (MPPB) at the West Valley Demonstration Project (WVDP) is currently undergoing decontamination and decommissioning activities under the purview of the Department of Energys (DOE) Office of Environmental Management (EM). When the hazards in the buildings have been adequately reduced, the ventilation exhaust systems will be shut down and the MPPB structures will be demolished in open air.
This document presents the results of air dispersion modeling developed during the planning for open-air demolition of the MPPB. The modeling has been performed in a sequential manner following the current open-air demolition schedule. This approach allows for the model to account for and include building wake effects at each step in the demolition process.
Inventory Discussion The WVDP maintains a Characterization Database, which includes the MPPB radiological contamination inventory. This information is contained in a raw data table that includes the data as measured in the field and laboratory. The raw data contained in this table was used to select and implement decontamination and inventory reduction methods conducted prior to entering the demolition phase of the project. For example, the raw data table contains the radionuclide contamination levels in tanks and pipes that have been foamed; effectively sealing the contamination from release. The tanks will be removed as sealed units during demolition. Reduction or elimination of the inventory contained in the raw data table has been performed in this document when appropriate based on the decontamination and inventory reduction methods employed.
The inventory or material at risk (MAR) presented in this document is based on the Characterization Database as it existed June 20, 2020. A listing of the MAR grouped by demolition method to be applied to each structure in the MPPB can be found in WVDP-606 Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H.1 Assumptions
- 1. Contamination is evenly distributed on surfaces
- 2. Nitrocision will reduce the inventory in PPC-S by 80%. The inventory remaining in PPC-S will be re-evaluated after completion of nitrocision and appropriate revisions, including the possible removal of this assumption will be made at that time.
- 3. Pipes that are greater than or equal to 1-inch in diameter and are less than or equal to 60 inches in length are embedded in a wall and have been foam filled. Assume that 10% of these pipes are damaged enough to release radionuclides.2 Unless note elsewhere in this document, all other pipes are assumed to be removed with a mechanical shear.
1 The MAR in this document includes two radionuclides of environmental concern, namely I-129 and Tc-99. These two radionuclides are not in the characterization database and are not included in the MAR used in this document. Other than those two radionuclides, the MAR and the assumptions are the same.
2 Except for a few locations, the piping has been cut near the wall and removed. The only section of piping remaining is in the walls. Pipes that were large enough to be foamed have been foamed. The assumption handles the case where a pipe gets ruptured during demolition of the wall and for some reason was not completely foamed and therefore might release some material. The pipes not removed remained in the MAR with no reduction for foaming.
WVDP-607 Rev. 1 Page 4 of 28 4
Airborne release rates are based on the MAR present during each schedule activity. The release rates are based on the emission factors presented in Methodologies for Radionuclide Source Term Calculations for Air Emissions from Demolition Activities, Rev 1, hereafter referred to as the Alternative Method.
The Alternative Method was approved by Region 2 of the U.S. Environmental Protection Agency (EPA) on July 17, 2019.
Demolition Methods and MAR adjustments When demolition of the MPPB is undertaken, the physical demolition can involve equipment such as mechanical shears, saws, hydraulic hammers, and other means that are appropriate for the type of structure. In general, the following assumptions have been made as to the use of various demolition methods.
Hydraulic Hammering: This method has been assumed for all walls and structures.
Mechanical Shearing: This method has been assumed for all pipes that are not embedded in concrete walls.
Excavator Concrete Saw (EPA 40 CFR 61 Appendix D methodology): During open-air demo, this method is to be applied to the north wall corner in the Off-Gas Cell (OGC). Use of the excavator saw will be controlled by the WIP.
Diamond Wire: There are no plans to use this method for MPPB demolition.
Hot-cutting: The Oxylance cutting will not be used. Cutting for maintenance purposes may be required. When hot cutting is required an approved RCE calculation will be completed prior to authorizing the activity.
Three walls in the database are shared with a structure that will not be demolished, and as such will not be removed.
As discussed in the Alternative Method, radionuclides contained in a sealed container or package are not included in the building inventory for purposes of estimating emissions. Several rooms and niches have liners that will be fixed, folded and removed as sealed units.
More detail on these adjustments and listings of each structure with an adjusted MAR is contained in WVDP-606 Main Plant Process Building Radionuclide Inventory for 40 CFR 61 Subpart H.
WVDP-607 Rev. 1 Page 5 of 28 5
Air Dispersion Model Setup The EPA model, AERMOD3, was used to estimate atmospheric concentrations for released radiological material due to proposed demolition activities. Structures making up the MPPB were input into the model such that each structure could be removed as the proposed demolition activities progressed.
Surrounding buildings that will be present when open-air demolition of the MPPB begins were also input into the model. This approach allows for the model to account for building wake effects and downwash due to the remaining MPPB structures and the surrounding buildings. Structures in the path of a plume can modify the air concentrations around and behind the building due to effects such as eddy or cavity formation, and channeling. The AERMOD family of models contains preprocessors (BPIPPRM) that account for these building wake effects for point sources. For the MPPB demolition, the blue areas in Figure 1 represent all the structures that are in the AERMOD building files. The buildings and areas that comprise the MPPB (enclosed in a red circle in Figure 1) are input as separate structures. The advantage to inputting the facility being demolished in sections or areas is that when a section is removed during demolition the AERMOD file can be easily reconfigured and the BPIPPRM preprocessor routine rerun to establish correct building wake effects for the following demolition activities.
Met Data A five-year meteorological file (2014 - 2018) was developed using the latest version (19191) of the EPA AERMET software. The 5-year file was developed using meteorological data from the on-site meteorological tower, supplemented with data from the National Weather Service at the Cattaraugus County Olean Airport and the Buffalo/Niagara International Airport.
The met file was developed using the EPA supplied AERMET software. The software produces two met files, one that has surface data and the other that has profile data. To produce these files, basic data from the WVDP met tower is input a text file. That data is supplemented with data from the national weather service measured at the Olean Airport. The national weather service only has a few upper air collection sites, one being Buffalo/Niagara International Airport. Therefore, the upper winds file comes from the Buffalo/Niagara International Airport National Weather Service data. The AERMET software also requires land use data which comes from files provide by EPA. Local terrain data at the two surface met stations (Olean Airport and WVDP) is also required. That information is produced with the EPA supplied AERSURFACE tool which provides surface characteristic values, including albedo, Bowen ratio, and surface roughness length. AERMET then processes all of these data files to produce the surface data file and the profile data file.
Hourly onsite met data used in the production of the AERMOD met files includes:
Wind speed Wind direction Ambient air temperature 3 Breeze AERMOD, which consists of the AERMOD model (FORTRAN executable), obtained from EPA and compiled to run on a Windows operating system, and a custom graphical user interface that facilitates the manipulation of model input and output was used for this evaluation. The latest version of AERMOD, Version 19191 was used for the calculations.
WVDP-607 Rev. 1 Page 6 of 28 6
Figure 1: Buildings in the AERMOD model
WVDP-607 Rev. 1 Page 7 of 28 7
Sources Three virtual point sources4 were used for each sequence in the demolition schedule. A point source was placed at the point of demolition. Another point source was placed in the approximate area that a debris pile will be located. The final point source was placed at the location where waste boxes will be loaded.
The height of the virtual point sources representing demolition was established at approximately half the height of the structure being demolished. The height of each virtual point source and the associated lower and upper heights of the demolition area for each AERMOD run is included in Appendix A. Point sources are rounded down to the nearest full foot. The virtual point source representing load out emissions was set to a height of 5 ft, which is the approximate height of the waste boxes. For the debris piles a height of 5 ft was used for the virtual point source.
The temperature for all sources was set to ambient and the exit gas velocity was set to 0.001 m/s. With source temperature set to ambient and the source exit velocity set to 0.001 m/s, the effects on plume rise due to the diameter of the point source are nil. However, the AERMOD software requires a source diameter. The diameter for the demolition virtual point sources was set to 1 meter, the diameter of the load out source was set to 1 meter, and the diameter of the debris pile point source was set to 3 meters.
Receptors The AERMOD model for MPPB demolition includes receptors at a proposed CA/ARA (contamination area/ airborne radioactivity area), a site buffer area and the site security fence line. In addition, receptors have been placed at the location of 12 proposed ECAMs, 3 proposed ICAMs and 34 storm water catch basins near the MPPB structures. The receptor locations are shown in Figure 2.
Results from the AERMOD runs were converted to airborne radioactivity concentrations presented as a fraction of Derived Air Concentration (DAC). Derived air concentration (DAC) is defined in 10 CFR 835 as the airborne concentration that equals the Annual Limit on Intake (ALI) divided by the volume of air breathed by an average worker for a working year of 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> (assuming a breathing volume of 2400 m3). 10 CFR 835 defines ALI as the derived limit for the amount of radioactive material taken into the body of an adult worker by inhalation or ingestion in a year. ALI is the smaller value of intake of a given radionuclide in a year by the reference man (ICRP Publication 23) that would result in a committed effective dose of 5 rems or a committed equivalent dose of 50 rems to any individual organ or tissue. A limit was placed on the CA/ARA boundary of 0.3 DAC. The limit at the Buffer Area boundary was set at 0.02 DAC.
4 A point source is the only type of source for which AERMOD will include building wake effects.
WVDP-607 Rev. 1 Page 8 of 28 8
Figure 2: Receptors in the AERMOD model Surface Deposition Model Setup The EPA AERMOD model includes algorithms to estimate the depletion of particulate matter from the plume by dry deposition; i.e., deposition due primarily to particle characteristics and meteorological conditions other than precipitation. AERMOD utilizes a concept called deposition velocity to estimate the loss of particles from the plume, which are then deposited on the ground. The deposition velocities for small particles are dominated by Brownian motion, while those of larger particles are dominated by inertial impaction and gravitational settling. The surface deposition function in AERMOD can be used to estimate the ground contamination level due to the plume produced during open-air demolition. The deposition modeling can be used to evaluate projected ground level contamination against 10 CR 835 Appendix D surface contamination limits. For the MPPB, these limits would be 20 dpm/100 cm2 for alpha transuranics and 1000 dpm/100cm2 for beta-gamma emitters.
WVDP-607 Rev. 1 Page 9 of 28 9
To implement the dry deposition algorithm, an estimate of the particle size distribution for the source must be provided. The particle size distribution used in deposition analysis is based on studies conducted by MacMillan5 during demolition of concrete structures. The particle size and mass fractions are presented in Table 1. The maximum particle diameter was set at 50 m for the >15 m bin value.
Table 1: Aerodynamic Particle Size during demolition Particle Diameter (m)
Mass Fraction Percent Fraction
(%)
0 - 0.42 0.0472 4.72 0.42 - 0.76 0.0489 4.89 0.76 - 1.4 0.0447 4.47 1.4 - 2.2 0.1077 10.77 2.2 - 3.7 0.1658 16.58 3.7 - 9.2 0.1570 15.70 9.2 - 15 0.1873 18.73
>15 0.2415 24.15 In order to generate deposition isopleths, a polar grid receptor was added to the AERMOD models for those activities modeled for surface deposition.
Calculation of Emission Rates The Characterization Database has over 2200 sets of radiological data for the MPPB structure.
Contamination levels for each structure are an average of multiple (generally 5) samples, followed by a surface scan to ensure that the data is representative of the entire structure. An isotopic ratio is assigned to various locations in the MPPB based on prior knowledge resulting from laboratory analysis of waste collected from those areas.
Emission rates for demolition, debris pile emission and loading activities were assigned to each of the 2200+ structures using emission factors developed in the Alternative Method, which was approved by EPA on July 17, 2019 and is documented in WVDP-579, Vitrification Facility Air Emissions during Open-Air Demolition. These values are summarized in Table 2.
5 W.J. MacMillan, R.R. Brey, J.T. Harris, Particle Size Characterization of Aerosols Generated during Surface Contaminated Concrete Demolition, Operational Radiation Safety, Vol 104, Suppl 2, May 2013
WVDP-607 Rev. 1 Page 10 of 28 10 Table 2: Emission Factors for Demolition Methods Method Emission Factor (Ci released per Ci processed)
Shearing 5.0E-05 Hydraulic Hammer 1.0E-05 Concrete Saw Used EPA Appendix D method (40 CFR 61). Saw has a width of 0.65 inches. Cuts are typically made to produce a 3-foot by 3-foot surface area block. For the cuts, a physical state factor of 1.0E-03 is used and for the solid blocks the physical state factor is set to 1.0E-06.
The combined concrete saw emission factor is 8.92E-06 for the Off-Gas Cell (OGC) Corner.
Rubble Pile Emissions a)
(0.0016) 2.2
2
When a wind speed of 6.7 m/s and moisture content of 2% are assumed, the rubble pile emissions factor is 6.81E-06.
Load Out Emissions 2.9E-05 a)
Wind Speed set to 6.7 m/s Moisture content set to 2 %
Units for the pile are mCi released per Ci processed on an hourly basis.
The following assumptions are used throughout the calculations for development of emission rates.
- 1. Moisture content of the pile is conservatively assumed to be 2%. During the validation study the moisture content of the pile was not physically measured, however it was assumed to be 2% for piles containing mostly metal, while a value of 9% was used for concrete rubble piles.
- 2. Wind speed is conservatively assumed to be 6.7 m/s (15 mph). The average wind speed from 2014 through 2018 was 2.4 m/s and 99% of the measured wind speeds are less than or equal to 6.7 m/s.
- 3. The width of the kerf is assumed to be 0.65 inch for the concrete saw.
WVDP-607 Rev. 1 Page 11 of 28 11 The curie release rate for each radionuclide was converted to a mass basis using the specific activity of each isotope. The total mass emissions were then calculated for each structure as the sum of the radionuclide specific mass emissions.
As a conservative measure, a set of AERMOD demolition times were prepared that are significantly shorter than the times presented in the project schedule. See Appendix A for a listing of the AERMOD demolition times associated with each schedule activity. This approach will produce conservative emission rates.
For the demolition activities, each structure was assigned to a specific schedule activity. For a wall, the mass emissions would include both sides of the wall. For a ceiling the mass emissions would include the mass emission from the ceiling and from the floor above that ceiling. The total mass emission for a schedule activity was calculated as the sum of all emissions from each structure included in that schedule activity. The total mass emissions for a schedule activity were divided by the AERMOD schedule demolition time allowed for that demolition activity. The schedule times and the resulting emission rates for the demolition activities are provided in Appendix A.
For the load out emissions, the total mass emissions from each demolition sequence were divided by the AERMOD demolition time in the schedule. The schedule times and the resulting emission rates for the load out activities are provided in Appendix A.
It is assumed that the demolition debris from each schedule activity is loaded in a timely manner after demolition (generally 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />). In the validation study the debris pile emission rate was applied on an hourly basis. This practice was continued in this evaluation. The material produced as a result of demolition for a schedule activity was first divided by the schedule time in units of days. For those activities that were less than one day in length, a one-day period was used. The quantity of material produced by the daily demolition was then multiplied by the pile emission rate based on a 1-hour period; i.e., it is assumed that the pile emits on an hourly basis the resulting product of the pile inventory times the pile emission factor. The schedule times and the resulting emission rates for the debris pile activities are provided in Appendix A.
DAC Calculations The results from the Air Dispersion Modeling provides supporting data for the selection of the radiological boundaries as required by 10 CFR 835. A ratio of the air mass concentration to the mass DAC was determined for each schedule activity evaluated with AERMOD. The activity DAC values (Ci/ml) found in Appendix A of 10 CFR 835 can be converted to mass DAC values with units of g/m3 (AERMOD provides results in units of g/m3) by using the specific activity of the radionuclide of interest. In the case of MPPB demolition, the radionuclides of interest along with the activity DAC and the mass DAC are presented in Table 3.
WVDP-607 Rev. 1 Page 12 of 28 12 Table 3: Radionuclide data Radionuclide Activity DAC (Ci/ml)
Mass DAC (g/m3)
Sp. Activity (Ci/g)
Am-241 5.00E-12 1.46E-06 3.430E+00 Cm-243 7.00E-12 1.35E-07 5.170E+01 Cm-244 9.00E-12 1.08E-07 8.330E+01 Cs-137 8.00E-08 9.20E-04 8.700E+01 Np-237 8.00E-12 1.13E-02 7.050E-04 Pu-238 6.00E-12 3.50E-07 1.713E+01 Pu-239 5.00E-12 8.04E-05 6.220E-02 Pu-240 5.00E-12 2.19E-05 2.280E-01 Pu-241 2.00E-10 1.94E-06 1.030E+02 Sr-90 1.00E-08 7.30E-05 1.370E+02 U-232 2.00E-11 9.34E-07 2.141E+01 U-233 7.00E-11 7.25E-03 9.650E-03 U-234 7.00E-11 1.12E-02 6.240E-03 U-235 8.00E-11 3.70E+01 2.160E-06 U-238 8.00E-11 2.39E+02 3.350E-07 For each schedule activity, a DAC value per unit total mass per cubic meter (DAC/(g/m3)) was calculated. To determine this factor, the radionuclide activity distribution applicable to a schedule activity was converted to a mass distribution through the use of the specific activity values given in Table 3. This mass distribution was then normalized to total mass to determine the fractional mass contribution of each nuclide to the total mass in the schedule activity radionuclide distribution. A DAC sum-of-fractions for the schedule activity radionuclide distribution was then calculated by dividing the nuclide mass fraction of each nuclide by the nuclides mass DAC given in Table 3 and adding the fractions of all nuclides in the distribution. The mass air dispersion concentrations (g/m3) from the AERMOD runs for a schedule activity was multiplied the radionuclide mass ratio DAC values. The result of this calculation is a DAC value for the schedule activity. A limit of 0.3 for this DAC value was used for the CA/ARA boundary. A limit of 0.02 for this DAC value was used for the Buffer Area boundary.
Surface Deposition Calculations Results from the AERMOD runs are converted from g/m2, the default output for a dry deposition run, to dpm/100 cm2 based on the general isotopic data for the area being evaluated. For the MPPB surface deposition evaluation, two higher contamination areas that have very different radionuclide distributions were selected for the deposition evaluation.
WVDP-607 Rev. 1 Page 13 of 28 13 The first deposition evaluation was done using the source term for the Extraction Cell 2 (XC2) West wall demolition (Schedule activity 1060170101085A). The mass ratio by radionuclide in this area is presented in Table 4 along with the conversion values. The primary radionuclides in the XC2 area are alpha emitters. Assuming a unit g/m2 deposition value the g/m2 deposition levels predicted by AERMOD can be converted in this area to dpm/100 cm2 Alpha with a multiplication factor of 2.46E+07, the g/m2 deposition levels predicted by AERMOD can be converted in this area to dpm/100 cm2 Beta with a multiplication factor of 1.94E+07.
Table 4: XC2 west wall conversion from g/m2 to dpm/100cm2 Radionuclide Mass Ratio Ci/m2 Ci/cm2 Ci/100cm2 dpm/100cm2 Cs-137 4.39E-06 3.82E-04 3.82E-08 3.82E-06 8.48E+06 Sr/Y-90 3.60E-06 4.93E-04 4.93E-08 4.93E-06 1.09E+07 Cm-243 3.79E-10 1.96E-08 1.96E-12 1.96E-10 4.35E+02 Cm-244 5.43E-09 4.53E-07 4.53E-11 4.53E-09 1.00E+04 Np-237 2.41E-05 1.70E-08 1.70E-12 1.70E-10 3.77E+02 Am-241 1.86E-04 6.38E-04 6.38E-08 6.38E-06 1.42E+07 Pu-238 1.24E-05 2.12E-04 2.12E-08 2.12E-06 4.71E+06 Pu-239 2.33E-03 1.45E-04 1.45E-08 1.45E-06 3.22E+06 Pu-240 4.85E-04 1.11E-04 1.11E-08 1.11E-06 2.46E+06 Pu-241 1.82E-05 1.87E-03 1.87E-07 1.87E-05 4.16E+07 U-232 5.05E-09 1.08E-07 1.08E-11 1.08E-09 2.40E+03 U-233 1.09E-04 1.05E-06 1.05E-10 1.05E-08 2.34E+04 U-234 8.18E-05 5.10E-07 5.10E-11 5.10E-09 1.13E+04 U-235 3.54E-01 7.64E-07 7.64E-11 7.64E-09 1.70E+04 U-238 6.43E-01 2.15E-07 2.15E-11 2.15E-09 4.78E+03 Total Beta (dpm/100cm2 per g/m2) 1.94E+07 Total Alpha (dpm/100cm2 per g/m2) 2.46E+07 The second deposition evaluation was done using the source term for the bottom portion of the Chemical Process Cell (CPC) East wall demolition (Schedule activity 1060170101082). The mass ratio by radionuclide in this area is presented in Table 5 along with the conversion values. This area has a more even mix of alpha and beta emitters. Assuming a unit g/m2 deposition value the g/m2 deposition levels predicted by AERMOD can be converted in this area to dpm/100 cm2 Alpha with a multiplication factor of 3.80E+07, the g/m2 deposition levels predicted by AERMOD can be converted in this area to dpm/100 cm2 Beta with a multiplication factor of 5.22E+08.
WVDP-607 Rev. 1 Page 14 of 28 14 Table 5: CPC east wall bottom section conversion from g/m2 to dpm/100cm2 Radionuclide Mass Ratio Ci/m2 Ci/cm2 Ci/100cm2 dpm/100cm2 Cs-137 7.34E-05 6.38E-03 6.38E-07 6.38E-05 1.42E+08 Sr/Y-90 1.25E-04 1.71E-02 1.71E-06 1.71E-04 3.80E+08 Cm-243 1.48E-08 7.66E-07 7.66E-11 7.66E-09 1.70E+04 Cm-244 2.05E-07 1.71E-05 1.71E-09 1.71E-07 3.80E+05 Np-237 1.03E-04 7.28E-08 7.28E-12 7.28E-10 1.62E+03 Am-241 2.68E-04 9.19E-04 9.19E-08 9.19E-06 2.04E+07 Pu-238 1.87E-05 3.21E-04 3.21E-08 3.21E-06 7.13E+06 Pu-239 3.81E-03 2.37E-04 2.37E-08 2.37E-06 5.26E+06 Pu-240 7.87E-04 1.79E-04 1.79E-08 1.79E-06 3.98E+06 Pu-241 2.72E-05 2.80E-03 2.80E-07 2.80E-05 6.21E+07 U-232 1.05E-06 2.25E-05 2.25E-09 2.25E-07 5.00E+05 U-233 9.13E-04 8.81E-06 8.81E-10 8.81E-08 1.96E+05 U-234 6.70E-04 4.18E-06 4.18E-10 4.18E-08 9.28E+04 U-235 1.36E-02 2.93E-08 2.93E-12 2.93E-10 6.51E+02 U-238 9.80E-01 3.28E-07 3.28E-11 3.28E-09 7.29E+03 Total Beta (dpm/100cm2 per g/m2) 5.22E+08 Total Alpha (dpm/100cm2 per g/m2) 3.80E+07 Results Discussion Data was evaluated using the predicted 95% percentile daily (8-hour) air concentrations.
A typical plot of the predicted 95% percentile 8-hour air concentrations is presented in Figure 3. The 8-hour maximum DAC value, which is given in Appendix A for each activity, was always located within the CA/ARA boundary. The plot shows the DAC value at each receptor, including the CA/ARA boundary, the Buffer Area boundary, near sections of the property fence, and at the proposed locations of ECAM and ICAM monitoring equipment. Using the demolition times listed in Appendix A for each schedule activity, all of the activities passed the boundary tests; i.e., all receptor values on the CA/ARA do not exceed a 0.3 DAC value and all receptor values on the Buffer Area boundary do not exceed the 0.02 DAC value. For a detailed listing of the results of the AERMOD dispersion modeling results see Appendix A.
WVDP-607 Rev. 1 Page 15 of 28 15 Figure 3: Example of DAC values at boundary receptors (run 25)
Evaluation of surface deposition6 is presented for two demolition activities. The two activities selected are areas of higher contamination, but with very different radionuclide contamination matrices. The predicted 95% percentile daily (8-hour) surface deposition values for both activities are within the limits of 20 dpm/100cm2 alpha and 1000 dpm/100cm2 beta at the CA/ARA boundary.
For surface deposition, two types of plots were prepared. One type presents the predicted surface deposition at each receptor which includes the CA/ARA boundary, the Buffer boundary, near sections of the property fence, and at the proposed locations of ECAM and ICAM monitoring equipment. In addition, an isopleth of the predicted surface deposition was also prepared. These plots are presented as Figure 4 - Figure 11. In both cases any contamination areas that exceed the 10 CFR 835 contamination level values are within the proposed contamination area boundaries.
6 Surface deposition model runs with AERMOD have been limited to 15 mph winds. Additional evaluations using other methods and wind speeds up to 30 mph are being prepared as a separate activity.
WVDP-607 Rev. 1 Page 16 of 28 16 Figure 4: Example of Contamination Levels CPC East Wall bottom portion - beta
WVDP-607 Rev. 1 Page 17 of 28 17 Figure 5: Example of Contamination Levels CPC East Wall bottom portion - alpha
WVDP-607 Rev. 1 Page 18 of 28 18 Figure 6: CPC East Wall bottom portion isopleth-beta Contamination
WVDP-607 Rev. 1 Page 19 of 28 19 Figure 7: CPC East Wall bottom portion isopleth-alpha Contamination
WVDP-607 Rev. 1 Page 20 of 28 20 Figure 8: Example of Contamination Levels XC2 west wall - beta
WVDP-607 Rev. 1 Page 21 of 28 21 Figure 9: Example of Contamination Levels XC2 west wall -alpha
WVDP-607 Rev. 1 Page 22 of 28 22 Figure 10: XC2 west wall isopleth -beta Contamination
WVDP-607 Rev. 1 Page 23 of 28 23 Figure 11: XC2 west wall isopleth -alpha Contamination
WVDP-607 Rev. 1 Page 24 of 28 24 Appendix A Schedule, Emission Rates, & Results
WVDP-607 Rev. 1 Page 25 of 28 25 Schedule (1)
Description AERMOD Days Demo (g/s)
Pile (g/s)
Load (g/s)
AERMOD Run Number (2)
DAC Converter DAC/(g/m3)
Demolition Heights Maximum DAC Value Point Source (3)
(ft)
Lower Height (ft)
Upper Height (ft)
ICAM Or ECAM Site Fence RBA CA 1060170101001 Solvent Storage Terrace (SST) 0.1 1.95E-11 6.37E-11 5.66E-11 1
2.43E+07 39 34 44.5 8.2E-06 1.2E-06 5.6E-06 1.2E-05 1060170101002A Upper Warm Aisle (UWA) Structure for Access 0.1 2.34E-10 7.65E-10 6.79E-10 2
2.43E+07 24 14.5 34.5 9.9E-05 1.6E-05 6.6E-05 1.4E-04 1060170101002B Upper Warm Aisle (UWA) Shielded Pipe Chase Removal 0.1 1.80E-10 1.18E-10 1.05E-10 2
2.43E+07 24 14.5 34.5 9.9E-05 1.6E-05 6.6E-05 1.4E-04 1060170101002C Upper Warm Aisle (UWA) Removal of Niches (6) 9.0 1.87E-08 6.10E-07 5.42E-08 3
1.24E+07 15 14.5 34.5 1.0E-02 4.0E-03 1.5E-02 2.4E-02 1060170101002D Upper Warm Aisle (UWA) Remaining Structure 0.1 1.50E-13 4.89E-13 4.34E-13 3
2.43E+07 15 14.5 34.5 1.0E-02 4.0E-03 1.5E-02 2.4E-02 1060170101003C Lower Warm Aisle (LWA) Remaining Structure 0.1 1.35E-10 4.40E-10 3.90E-10 4
2.43E+07 7
0 14.5 1.1E-04 1.8E-05 7.5E-05 1.6E-04 1060170101004 Extraction Chemical Room (XCR) (South Structure) 0.1 4.73E-10 1.55E-09 1.37E-09 5
2.43E+07 69 60 79 2.1E-04 3.4E-05 8.3E-05 1.9E-04 1060170101084C Extraction Cell #1 (XC-1) South Wall Structure 3.0 2.86E-09 2.46E-08 2.18E-09 6
2.77E+08 30 0
60 2.1E-02 2.9E-03 1.7E-02 3.9E-02 1060170101085C Extraction Cell #2 (XC-2) South Wall Structure 3.0 4.09E-10 5.35E-09 4.75E-10 7a 2.21E+08 30 0
60 3.6E-03 5.0E-04 2.9E-03 6.7E-03 1060170101085A Extraction Cell #2 (XC-2) West Wall Structure 8.0 5.02E-10 1.49E-08 1.32E-09 7b 2.24E+08 30 0
60 9.9E-03 1.4E-03 8.0E-03 1.9E-02 1060170101086C Extraction Cell #3 (XC-3) South Wall Structure 7.0 4.46E-10 1.46E-08 1.29E-09 8a 4.52E+08 30 0
60 3.5E-03 8.6E-04 2.0E-03 3.3E-03 1060170101086A Extraction Cell #3 (XC-3) West Wall Structure 8.0 5.77E-10 1.88E-08 1.67E-09 8b 1.43E+08 30 0
60 4.3E-03 1.1E-03 7.2E-03 1.1E-02 1060170101019 Off-Gas Operating Aisle (OGA) 1.0 2.37E-11 7.33E-10 6.51E-11 9
1.76E+08 37 31 44 2.0E-04 4.9E-05 1.2E-04 2.7E-04 1060170101021 Acid Recovery Cell (ARC) 3.0 2.32E-10 7.57E-09 6.72E-10 10 7.66E+07 21 11.5 31 6.5E-04 2.4E-04 1.4E-03 3.2E-03 1060170101022 Acid Recovery Pump Room (ARPR) 3.0 3.73E-12 1.22E-10 1.08E-11 11 4.35E+08 7
0 14.5 1.1E-04 3.7E-05 2.2E-04 4.9E-04 1060170101024A Off Gas Blower Room (OGBR) 3.0 6.13E-12 2.00E-10 1.78E-11 12 3.75E+08 7
0 14.5 9.1E-05 2.4E-05 5.0E-05 1.2E-04 1060170101020 Top of South Stairs 0.1 6.33E-12 2.07E-11 1.84E-11 13a 2.43E+07 61 44 79 1.2E-06 3.1E-07 6.0E-07 1.4E-06 1060170101023 Remainder of South Stairs 0.1 1.24E-10 4.06E-10 3.60E-10 13b 2.43E+07 11.5 0
0 2.3E-05 7.0E-06 1.3E-05 2.9E-05 1060170101074B Off Gas Cell (OGC) Remainder of Structure 3.0 1.31E-10 4.00E-09 3.55E-10 14a 3.41E+08 15 0
31 1.7E-03 4.3E-04 9.1E-04 2.2E-03 1060170101074A Northwest Corner of Off Gas Cell (OGC) 8.0 9.21E-08 0.00E+00 0.00E+00 14b 3.40E+08 15 0
31 1.6E-02 1.0E-02 1.6E-02 2.9E-02 1060170101084A Extraction Cell #1 (XC-1) West Wall Structure 4.0 1.88E-10 6.14E-09 5.46E-10 15 2.88E+08 30 0
60 2.1E-03 5.5E-04 1.2E-03 2.9E-03 1060170101025 Ventilation Exhaust Cell (VEC) Plenum 3.0 2.70E-08 8.83E-07 7.84E-08 16 2.43E+07 56 48 64 2.5E-02 6.6E-03 1.4E-02 3.5E-02 1060170101027 Ventilation Exhaust Cell (VEC) 1.0 1.28E-08 4.17E-07 3.70E-08 17a 2.43E+07 56 48 64 1.2E-02 3.1E-03 6.6E-03 1.7E-02 1060170101028 Hot Acid Cell (HAC) 0.1 1.25E-09 3.82E-09 3.39E-09 17b 2.43E+07 56 48 64 2.3E-04 5.8E-05 1.1E-04 2.6E-04 1060170101029 Process Chemical Room (PCR) 0.1 5.12E-10 1.67E-09 1.49E-09 17b 2.43E+07 56 48 64 2.3E-04 5.8E-05 1.1E-04 2.6E-04 1060170101075B Chemical Process Cell (CPC) Access Interior Through West Wall 9.0 3.33E-10 1.06E-08 9.37E-10 18 3.40E+08 24 0
48 4.3E-03 1.1E-03 2.4E-03 5.9E-03 1060170101075D Chemical Process Cell (CPC) Remove South Wall Including Ceiling Above 12.0 1.57E-09 5.13E-08 4.56E-09 19a 2.92E+08 52 44 60 1.7E-02 4.6E-03 9.8E-03 2.4E-02 1060170101063A Extraction Chemical Room (XCR) West Portion 0.1 1.88E-11 6.15E-11 5.46E-11 19b 2.43E+07 69 60 79 8.2E-03 3.1E-03 4.1E-03 1.6E-02 1060170101061 Upper Extraction Aisle (UXA) West Portion 0.1 5.29E-08 1.73E-07 1.53E-07 19b 2.43E+07 69 60 79 8.2E-03 3.1E-03 4.1E-03 1.6E-02 1060170101063B Control Room (CR) - West Portion 0.1 1.82E-09 5.96E-09 5.29E-09 19b 2.43E+07 69 60 79 8.2E-03 3.1E-03 4.1E-03 1.6E-02 CPC Upper E-Wall CPC Upper E-Wall 7.0 7.90E-10 2.58E-08 2.29E-09 20 3.40E+08 37 31 44 9.4E-03 3.3E-03 4.5E-03 1.4E-02 1060170101070 Analytical Decontamination Aisle (ADA) 0.1 3.67E-11 1.20E-10 1.06E-10 21 4.16E+08 37 31 44 2.1E-02 5.9E-03 1.8E-02 2.9E-02 1060170101078 ICP Lab 0.1 1.57E-11 5.14E-11 4.56E-11 21 2.43E+07 37 31 44 2.1E-02 5.9E-03 1.8E-02 2.9E-02 1060170101076B Sample Storage Cell (SSC) Remove Remainder of Cell 2.0 7.75E-09 6.64E-08 5.90E-09 21 2.23E+08 37 31 44 2.1E-02 5.9E-03 1.8E-02 2.9E-02 1060170101051 Control Room (CR) 0.1 3.28E-10 1.07E-09 9.50E-10 22 2.43E+07 52 44 60 5.5E-05 2.0E-05 2.6E-05 1.0E-04 1060170101077 CTS Lab 0.1 6.35E-11 2.08E-10 1.84E-10 22 2.43E+07 52 44 60 5.5E-05 2.0E-05 2.6E-05 1.0E-04
WVDP-607 Rev. 1 Page 26 of 28 26 Schedule (1)
Description AERMOD Days Demo (g/s)
Pile (g/s)
Load (g/s)
AERMOD Run Number (2)
DAC Converter DAC/(g/m3)
Demolition Heights Maximum DAC Value Point Source (3)
(ft)
Lower Height (ft)
Upper Height (ft)
ICAM Or ECAM Site Fence RBA CA 1060170101050 Extraction Chemical Room (XCR) North Portion of Structure 0.1 2.52E-10 8.22E-10 7.30E-10 22 2.43E+07 52 44 60 5.5E-05 2.0E-05 2.6E-05 1.0E-04 1060170101084B Extraction Cell #1 (XC-1) North Wall Structure 4.0 1.19E-10 3.88E-09 3.44E-10 23 2.74E+08 52 44 60 1.3E-03 4.2E-04 5.4E-04 1.8E-03 1060170101064A Sample Cell #2 (SC2) Window Removal 0.1 1.31E-10 4.27E-10 3.79E-10 24 1.16E+09 37 31 44 1.1E-03 3.9E-04 5.1E-04 2.0E-03 1060170101064B Sample Cell #2 (SC2) Remainder of Cell 0.1 1.58E-10 5.18E-10 4.60E-10 24 8.78E+08 37 31 44 1.1E-03 3.9E-04 5.1E-04 2.0E-03 1060170101065A Hot Cell #1 Shield Window Removal 1.0 1.01E-11 3.30E-10 2.93E-11 25 1.93E+10 37 31 44 2.6E-02 9.4E-03 1.5E-02 3.5E-02 1060170101065B Remainder of Hot Cell #1 1.0 2.07E-09 1.44E-08 1.28E-09 25 1.85E+09 37 31 44 2.6E-02 9.4E-03 1.5E-02 3.5E-02 1060170101066A Hot Cell #2 Shield Window Removal 1.0 2.18E-12 7.12E-11 6.32E-12 26 1.21E+09 37 31 44 1.2E-02 4.4E-03 7.0E-03 1.6E-02 1060170101066B Remainder of Hot Cell #2 1.0 2.05E-09 1.39E-08 1.23E-09 26 8.93E+08 37 31 44 1.2E-02 4.4E-03 7.0E-03 1.6E-02 1060170101067A Hot Cell #3 Shield Window Removal 1.0 6.76E-11 2.21E-09 1.96E-10 27 1.16E+09 37 31 44 1.4E-02 5.0E-03 8.0E-03 1.9E-02 1060170101067B Remainder of Hot Cell #3 1.0 2.10E-09 1.55E-08 1.38E-09 27 9.19E+08 37 31 44 1.4E-02 5.0E-03 8.0E-03 1.9E-02 1060170101068A Hot Cell #4 Shield Window Removal 1.0 4.80E-15 1.57E-13 1.39E-14 28 5.78E+10 37 31 44 1.3E-02 4.7E-03 7.4E-03 1.7E-02 1060170101068B Remainder of Hot Cell #4 1.0 2.06E-09 1.41E-08 1.25E-09 28 9.37E+08 37 31 44 1.3E-02 4.7E-03 7.4E-03 1.7E-02 1060170101069A Hot Cell #5 Shield Window Removal 1.0 6.63E-12 2.17E-10 1.92E-11 29 1.16E+09 37 31 44 1.3E-02 4.9E-03 7.8E-03 1.8E-02 1060170101069B Remainder of Hot Cell #5 1.0 2.04E-09 1.36E-08 1.21E-09 29 8.89E+08 37 31 44 1.3E-02 4.9E-03 7.8E-03 1.8E-02 1060170101079A Chemical Process Cell (CPC) East Wall to 1C Sampler below 131 7.0 8.09E-10 2.64E-08 2.35E-09 30 3.33E+08 22 14.5 31 6.5E-03 8.4E-03 4.2E-03 9.3E-03 1060170101079B Chemical Process Cell (CPC) 1C Sampler Removal 2.0 1.14E-13 1.28E-12 1.14E-13 30 1C 5.78E+10 22 14.5 31 9.4E-05 3.1E-05 4.0E-05 1.3E-04 1060170101082 Bottom Portion of Chemical Process Cell (CPC) East Wall 16.0 6.92E-10 2.26E-08 2.01E-09 30a 3.40E+08 22 14.5 31 1.2E-02 2.9E-03 1.5E-02 2.3E-02 1060170101072 Chemical Operating Aisle (COA) South Portion (Bays 4 & 5) 0.5 6.63E-09 2.99E-08 5.31E-09 31 8.49E+07 30 30 31 3.5E-03 1.2E-03 1.6E-03 5.2E-03 1060170101081 West Mechanical Operating Aisle (WMOA) South Portion 0.1 4.12E-10 1.14E-09 1.01E-09 32a 2.43E+07 14 13.5 14.5 5.9E-05 2.3E-05 3.3E-05 1.0E-04 1060170101036A West Mechanical Operating Aisle 0.1 3.28E-11 1.07E-10 9.52E-11 32a 2.43E+07 14 13.5 14.5 5.9E-05 2.3E-05 3.3E-05 1.0E-04 1060170101079C Chemical Process Cell (CPC) Remaining East Wall 9.0 6.20E-10 2.03E-08 1.80E-09 32b 3.40E+08 7
0 14.5 8.7E-03 2.8E-03 3.7E-03 1.2E-02 1060170101073A Liquid Waste Cell (LWC) Ceiling 2.0 4.25E-10 1.39E-08 1.23E-09 33a 5.68E+08 7
0 14.5 9.9E-03 3.2E-03 4.0E-03 1.4E-02 1060170101073C Liquid Waste Cell (LWC) Remainder of Cell 1.0 3.53E-09 6.92E-08 6.15E-09 33b 1.34E+08 7
0 14.5 8.4E-03 3.2E-03 5.2E-03 1.2E-02 1060170101011 Continuation of Extraction Chemical Room (XCR) East Structure 0.1 4.13E-10 1.35E-09 1.20E-09 36 2.43E+07 61 44 79 5.7E-05 2.2E-05 2.9E-05 9.8E-05 1060170101012 Control Room (CR) 0.1 6.59E-11 2.15E-10 1.91E-10 36 2.43E+07 61 44 79 5.7E-05 2.2E-05 2.9E-05 9.8E-05 1060170101052 Upper Extraction Aisle (UXA) 0.1 9.32E-11 3.04E-10 2.70E-10 36 2.43E+07 61 44 79 5.7E-05 2.2E-05 2.9E-05 9.8E-05 1060170101054 Analytical Laboratory 0.1 4.67E-11 1.53E-10 1.36E-10 37 2.43E+07 37 31 44 5.6E-04 2.2E-04 2.9E-04 9.8E-04 1060170101055 Radiochemistry Laboratory 0.1 1.41E-09 4.60E-09 4.08E-09 37 7.02E+07 37 31 44 5.6E-04 2.2E-04 2.9E-04 9.8E-04 1060170101056 Extraction Sample Aisle (XSA) West Portion 0.1 2.24E-11 7.31E-11 6.49E-11 38a 2.43E+07 30 0
60 3.1E-04 1.1E-04 1.9E-04 4.2E-04 1060170101085B Extraction Cell #2 (XC-2) North Wall Structure 3.0 4.80E-11 1.57E-09 1.39E-10 38a 2.16E+08 30 0
60 3.1E-04 1.1E-04 1.9E-04 4.2E-04 1060170101058 Lower Extraction Aisle (LXA) 1.0 1.84E-09 3.84E-08 3.41E-09 38b 4.93E+07 14 13.5 14.5 1.7E-03 6.5E-04 1.1E-03 2.4E-03 1060170101060A Ventilation Wash Room (VWR) Ceiling and East Wall 1.0 8.22E-10 2.69E-08 2.38E-09 39 8.77E+08 22 14.5 31 2.1E-02 8.0E-03 1.3E-02 2.9E-02 1060170101060D Ventilation Wash Room (VWR) Remaining South Wall 1.0 9.80E-11 3.20E-09 2.84E-10 39 8.84E+08 22 14.5 31 2.1E-02 8.0E-03 1.3E-02 2.9E-02 1060170101062 Ram Equipment Room (RER) East Wall 0.1 1.09E-10 3.56E-10 3.16E-10 41 2.43E+07 7
0 14.5 1.5E-05 6.3E-06 9.9E-06 2.7E-05 1060170101013 Upper Extraction Aisle (UXA) 0.1 3.17E-10 1.03E-09 9.18E-10 42 2.43E+07 61 44 79 3.7E-05 1.5E-05 2.3E-05 6.7E-05 1060170101014 Analytical Chemistry Lab (ACL) 0.1 8.88E-11 2.90E-10 2.57E-10 43 2.43E+07 37 31 44 3.6E-05 1.5E-05 2.3E-05 6.6E-05 1060170101015 3rd Floor Restroom 0.1 3.14E-10 1.02E-09 9.10E-10 43 2.43E+07 37 31 44 3.6E-05 1.5E-05 2.3E-05 6.6E-05
WVDP-607 Rev. 1 Page 27 of 28 27 Schedule (1)
Description AERMOD Days Demo (g/s)
Pile (g/s)
Load (g/s)
AERMOD Run Number (2)
DAC Converter DAC/(g/m3)
Demolition Heights Maximum DAC Value Point Source (3)
(ft)
Lower Height (ft)
Upper Height (ft)
ICAM Or ECAM Site Fence RBA CA 1060170101016 Extraction Sample Aisle (XSA) 0.1 2.12E-09 6.93E-09 6.15E-09 44 2.43E+07 22 14.5 31 2.5E-04 1.1E-04 1.6E-04 4.6E-04 1060170101086B Extraction Cell #3 (XC-3) North Wall Structure 4.0 7.60E-11 2.48E-09 2.20E-10 45 1.38E+08 30 0
60 2.2E-04 9.5E-05 2.1E-04 3.0E-04 1060170101059 Cell Access Aisle (CAA) West Portion 0.1 9.51E-11 3.11E-10 2.76E-10 46 2.43E+07 7
0 14.5 1.1E-05 5.0E-06 7.3E-06 2.1E-05 1060170101049 Cell Access Aisle (CAA) East Portion 0.1 5.68E-11 1.86E-10 1.65E-10 46 2.43E+07 7
0 14.5 1.1E-05 5.0E-06 7.3E-06 2.1E-05 1060170101048A Uranium Product Cell (UPC) Structure for Access 1.0 1.87E-11 6.10E-10 5.42E-11 47 1.17E+08 7
0 14.5 2.4E-04 1.0E-04 2.3E-04 3.2E-04 1060170101048D Uranium Product Cell (UPC) Remaining Structure 2.0 8.91E-11 2.90E-09 2.57E-10 47 1.37E+08 7
0 14.5 2.4E-04 1.0E-04 2.3E-04 3.2E-04 1060170101009 East Stairs 0.1 4.31E-10 1.41E-09 1.25E-09 48 2.43E+07 46 14.5 79 4.3E-05 1.9E-05 2.8E-05 8.2E-05 1060170101007A Uranium Load Out (ULO) Structure 2.0 1.03E-07 3.36E-06 2.98E-07 49 2.97E+05 7
0 14.5 1.5E-02 4.7E-03 1.2E-02 2.0E-02 1060170101007D Uranium Load Out (ULO) Remaining Structure 2.0 2.09E-06 6.81E-05 6.05E-06 49 3.07E+05 7
0 14.5 1.5E-02 4.7E-03 1.2E-02 2.0E-02 1060170101008 PSC#1 0.1 1.34E-10 4.36E-10 3.87E-10 50 2.43E+07 24 14.5 34 7.1E-04 2.4E-04 6.2E-04 9.8E-04 1060170101010 Product Packaging and Handling Area (PPH) 1.0 2.81E-08 9.16E-07 8.13E-08 50 1.16E+06 24 14.5 34 7.1E-04 2.4E-04 6.2E-04 9.8E-04 1060170101006 Product Packaging & Shipping (PPS) 0.1 5.38E-12 1.76E-11 1.56E-11 51 2.43E+07 7
0 14.5 7.1E-04 2.4E-04 6.2E-04 9.8E-04 1060170101005B Waste Receiving and Packaging Area (WRPA) Structure 0.1 4.99E-11 1.63E-10 1.45E-10 52 2.43E+07 6
0 12 3.4E-05 1.0E-06 1.1E-05 2.4E-05 GCRE GCRE 0.1 2.83E-10 9.26E-10 8.22E-10 54 2.43E+07 7
0 14.5 8.0E-05 2.1E-05 2.8E-05 1.0E-04 1060170101030A Chemical Process Cell (CPC) Penthouse 2.0 4.35E-11 1.42E-09 1.26E-10 55 3.40E+08 61 44 79 8.8E-04 2.1E-04 3.3E-04 1.0E-03 1060170101075E Chemical Process Cell (CPC) Remove North Wall Including Door and Ceiling Above 9.0 7.97E-11 2.60E-09 2.31E-10 56 3.40E+08 37 31 44 1.6E-03 3.9E-04 6.1E-04 1.9E-03 1060170101080 Chemical Operating Aisle (COA) Remainder 0.1 1.75E-11 3.12E-11 2.77E-11 58 2.43E+07 15 0
31 2.6E-06 7.4E-07 1.2E-06 3.4E-06 1060170101034 North Portion of Chemical Operating Aisle (COA) 0.1 1.49E-11 4.87E-11 4.33E-11 58 2.43E+07 15 0
31 2.6E-06 7.4E-07 1.2E-06 3.4E-06 1060170101030B Chemical Crane Room (CCR) Structure for Access 0.1 1.54E-09 5.04E-09 4.47E-09 61 3.40E+08 35 27 44 5.5E-03 1.5E-03 2.1E-03 7.1E-03 1060170101030F Chemical Crane Room (CCR) Remainder of Cell 2.0 3.94E-11 1.29E-09 1.14E-10 62 3.40E+08 37 31 44 8.0E-04 1.9E-04 3.0E-04 9.5E-04 1060170101035C Scrap Removal Room (SRR) Structure 0.1 3.95E-10 1.29E-09 1.15E-09 64 2.43E+07 8
0 17 8.0E-04 1.9E-04 3.0E-04 9.5E-04 1060170101033 Upper Section of North Stairs 0.1 1.42E-10 4.65E-10 4.13E-10 65 2.43E+07 8
0 17 3.7E-05 1.0E-05 1.8E-05 4.8E-05 1060170101032B EDR Viewing Aisle (EDRVA) Structure 0.1 5.01E-12 1.64E-11 1.45E-11 67 2.43E+07 37 27 47 3.7E-05 1.0E-05 1.8E-05 4.8E-05 1060170101031M Equipment Decontamination Room (EDR) Remainder of Structure 2.0 1.13E-10 3.69E-09 3.28E-10 68 3.40E+08 13 0
27 1.7E-03 4.7E-04 8.7E-04 1.9E-03 Vit Bay 18 Vit Bay 18 2.0 4.39E-13 1.43E-11 1.27E-12 69 4.44E+07 13 0
27 8.6E-07 2.4E-07 4.3E-07 9.5E-07 1060170101083K Process Mechanical Cell (PMC) South Wall to Access Ram 1.0 2.37E-09 7.73E-08 6.86E-09 76 3.98E+08 15 0
31 2.5E-02 9.6E-03 1.8E-02 3.2E-02 1060170101083M Process Mechanical Cell (PMC) Remainder of South Wall 1.0 1.35E-09 4.41E-08 3.92E-09 76 3.61E+08 15 0
31 2.5E-02 9.6E-03 1.8E-02 3.2E-02 1060170101083C Process Mechanical Cell (PMC) West Wall 8.0 8.79E-10 2.87E-08 2.55E-09 77 3.61E+08 15 0
31 8.6E-03 3.1E-03 6.4E-03 1.1E-02 1060170101046 Mass Spec Lab 0.1 3.56E-10 1.16E-09 1.03E-09 78 2.43E+07 37 31 44 5.9E-05 2.1E-05 3.0E-05 8.9E-05 1060170101038B Process Mechanical Cell Door Hoist Enclosure/Penthouse Structure 3.0 2.14E-10 7.00E-09 6.21E-10 79 3.61E+08 37 31 44 2.3E-03 7.9E-04 1.6E-03 3.0E-03 1060170101057 Ventilation Supply Room (VSR) South Portion 0.1 7.61E-10 2.49E-09 2.21E-09 81 2.43E+07 22 14.5 31 5.9E-03 2.0E-03 4.0E-03 7.5E-03 1060170101083F Process Mechanical Cell (PMC) East Wall to Inserts 6.0 5.38E-10 1.76E-08 1.56E-09 81 3.61E+08 22 14.5 31 5.9E-03 2.0E-03 4.0E-03 7.5E-03 1060170101047 Ventilation Supply Room (VSR) Middle Section 0.1 2.32E-09 7.57E-09 6.72E-09 82 2.43E+07 7
0 14.5 1.1E-02 3.8E-03 7.8E-03 1.4E-02 1060170101083H Process Mechanical Cell (PMC) Remainder of East Wall 3.0 1.01E-09 3.30E-08 2.93E-09 82 3.61E+08 7
0 14.5 1.1E-02 3.8E-03 7.8E-03 1.4E-02 1060170101071B East Mechanical Operating Aisle (EMOA) Including Shuttle Transport Room 0.1 8.59E-11 2.81E-10 2.49E-10 82 2.43E+07 7
0 14.5 1.1E-02 3.8E-03 7.8E-03 1.4E-02 1060170101071C East Mechanical Operating Aisle (EMOA) Shear 0.1 4.08E-10 1.33E-09 1.18E-09 82 2.43E+07 7
0 14.5 1.1E-02 3.8E-03 7.8E-03 1.4E-02
WVDP-607 Rev. 1 Page 28 of 28 28 Schedule (1)
Description AERMOD Days Demo (g/s)
Pile (g/s)
Load (g/s)
AERMOD Run Number (2)
DAC Converter DAC/(g/m3)
Demolition Heights Maximum DAC Value Point Source (3)
(ft)
Lower Height (ft)
Upper Height (ft)
ICAM Or ECAM Site Fence RBA CA 1060170101045 Ventilation Supply Room (VSR) North End 0.1 5.70E-10 1.86E-09 1.65E-09 82 1.09E+08 7
0 14.5 1.1E-02 3.8E-03 7.8E-03 1.4E-02 1060170101083D Process Mechanical Cell (PMC) North Wall Including Shield Door 6.0 3.94E-11 1.29E-09 1.14E-10 87 3.61E+08 7
0 14.5 4.4E-04 1.5E-04 3.1E-04 5.6E-04 1060170101037 Process Mechanical Cell Crane Room Enclosure (PMCRE) 0.1 1.98E-10 6.48E-10 5.75E-10 89 3.61E+08 37 31 44 4.9E-04 1.7E-04 2.6E-04 7.1E-04 1060170101039D Process Mechanical Crane Room (PMCR) Remaining Structure 3.0 3.60E-10 1.18E-08 1.04E-09 91 3.61E+08 22 14.5 31 3.9E-03 1.3E-03 3.0E-03 5.7E-03 1060170101041 Manipulator Repair Room 0.1 3.82E-10 1.25E-09 1.11E-09 92 3.61E+08 7
0 14.5 1.0E-03 3.5E-04 7.4E-04 1.5E-03 1060170101042 MSM South 0.1 8.91E-11 2.91E-10 2.58E-10 93 2.43E+07 7
0 14.5 1.9E-05 5.2E-06 1.1E-05 2.4E-05 1060170101088P Product Purification Cell - South (PPC-S) South Wall Structure TBD 1060170101087B Product Purification Cell - North (PPC-N) North Wall Structure TBD 1060170101087C Product Purification Cell - North (PPC-N) East Wall Structure TBD 1060170101088L Product Purification Cell - South (PPC-S) North Wall Structure TBD 1060170101088M Product Purification Cell - South (PPC-S) East Wall Structure TBD 1060170101088N Product Purification Cell - South (PPC-S) West Wall Structure TBD Notes:
- 1) Schedule activity that are highlighted are activities on an area that it is covered by another AERMOD run. In all cases the highlighted activities would have the same point source characteristics as the indicated AERMOD run number. However, the highlighted activities have lower emission rates and are bound by the indicated run number. These either lower release rates or much lower DAC conversion factors and are bounded by the other evaluation. For example, activity 1060170101065A, Hot Cell #1 Window is in the same demolition area as activity 1060170101065B, Remainder of Hot Cell #1.
- 2) AERMOD runs are numbered based on Appendix A of the WIP, therefore some numbers are skipped due to intermediate activities.
- 3) Point source heights are rounded down to the nearest full foot of height. Lower stack heights tend to produce higher air concentration values.
WVDP-607 Rev. 1 WV-1807, Rev. 10 (DCIP-101) i WVDP RECORD OF REVISION Revision On Rev. No.
Description of Changes Page(s)
Dated 0
Original Issue; based upon BC-RP-0131, Rev. 1, All 03/29/2021 authored by Brent Blunt under subcontract to CHBWV.
This document affects the Environment, Safety, Health, and Quality Departments; Facility Disposition Departments directly; and all WVDP departments indirectly.
1 Removed reference to BC-RP-0127 and changed All 04/20/2021 prior reference to BC-RP-0118 to new document 2, 3, 4 number WVDP-606, to avoid potential confusion.
This document affects the Environment, Safety, Health, and Quality Departments; Facility Disposition Departments directly; and all WVDP departments indirectly.