NRC Presentation for Public Meeting 10 CFR Part 53 Licensing and Regulation of Advanced Nuclear Reactors Subparts a and F Preliminary Proposed Rule Language
ML21125A161
Person / Time
Issue date: 05/06/2021
From: Robert Beall
NRC/NMSS/DREFS/RRPB
To:
Beall, Robert
References
10 CFR Part 53, NRC-2019-0062, RIN 3150-AK31
Download: ML21125A161 (61)


Text

May 6, 2021 10 CFR Part 53 Licensing and Regulation of Advanced Nuclear Reactors Subparts A and F Preliminary Proposed Rule Language 1

Agenda 10:00am - 10:15am Welcome / Introductions / Logistics / Goals 10:15am - 11:30am Subpart A - General Provisions 11:30am - 12:30pm Subpart F - Section 53.700, Operational Objectives and Controls on Equipment 12:30pm - 1:15pm 1:15pm - 1:45pm Lunch Break Subpart F - Section 53.700, Operational Objectives and Controls on Equipment (contd.)

1:45pm - 2:30pm Subpart F - Section 53.800, Programs 2:30pm - 2:45pm Break 2:45pm - 3:30pm Subpart F - Section 53.800, Programs (contd.)

3:30pm - 4:30pm Discussion on Previously Released Subparts and Integration of Subparts 4:30pm - 5:00pm Additional Public Comments/Closing Remarks 2

Welcome/Introductions Welcome:

John Segala, Office of Nuclear Reactor Regulation (NRR)

Speakers/Presenters:

Bob Beall, Office of Nuclear Materials Safety and Safeguards -

Rulemaking PM & Meeting Facilitator Jordan Hoellman, NRR - Part 53 Working Group Member Bill Reckley, NRR - Technical Lead Nanette Valliere, NRR - Technical Lead Public Meeting Slides: ADAMS Accession No. ML21125A161 3

Purpose of Todays Meeting Review preliminary proposed rule language for Part 53.

o Subpart A - General Provisions o

Subpart F - Requirements for Operations, Operational Objectives, and Programs Discuss previously released preliminary proposed rule language.

Todays meeting is a Comment-Gathering meeting, which means that public participation is actively sought in the discussion of the regulatory issues during the meeting.

o This meeting is being held in a workshop format to facilitate the discussion of todays topics.

o The meeting is being transcribed and the transcription will be available with the meeting summary by June 5, 2021.

No regulatory decisions will be made at todays meeting.

4

Plant Documents (Systems, Procedures, etc.)

Analyses (Prevention, Mitigation, Compare to Criteria)

Plant/Site (Design, Construction, Configuration Control)

Retirement Staffing &

Human Factors Configuration Control Surveillance Maintenance Operation Construction/

Manufacturing Construction Siting Design and Analysis LB Documents (Applications, SAR, TS, etc.)

NRC Staff Plan to Develop Part 53 Project Life Cycle System

& Component Design Analysis Requirements Subpart B Subpart C Subpart D Subpart E Subpart F Subpart G Subparts H & I Safety Categorization

& Special Treatment External Hazards Site Characteristics Environmental Considerations Ensuring Capabilities/

Reliabilities Change Control Environmental Considerations Programs Security, EP Facility Safety Program 5

Requirements Definition Safety Objectives Safety Criteria Safety Functions Other Subpart A General Provisions Subpart J Admin & Reporting Clarify Controls and Distinctions Between

NRC Staff Engagement Plan 6

Note that this is a living schedule and will be updated as needed throughout the rulemaking process.

Upcoming introductions of concepts and discussions of preliminary rule language will involve a variety of topics that have historically involved specific technical and programmatic specialties. To that end, stakeholders are encouraged to ensure that appropriate subject matter experts are involved in discussions of rule language and plans for guidance documents. An example is concepts and discussions within Subpart F (operations) that involve staffing levels and operator licensing.

Concept/Introduction Discussion Interim Staff Resolution Stakeholder Interactions Framework Safety Criteria Design Siting Construction Operations Decommissionin g

Licensing General/Admin Sept 20 Nov 20 Dec 20 Jan 21 Feb 21 Mar 21 Apr 21 May 21 Jun 21 Jul 21 Consolidated Technical Sections Aug 21 Consolidated Technical Sections Sept 21 Oct 21 Nov 21 Consolidated Rulemaking Package Dec 21 Jan 22 ACRS Full Committee Feb 22 Mar 22 Apr 22 May 22 Draft Proposed Rulemaking Package to the Commission Jun 22 Jul 22 Aug 22 Sept 22 Oct 22

7 General Provisions and Definitions - Subpart A

Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 8

10 CFR Part 53 Subpart A Layout

  • § 53.010 - Scope
  • § 53.020 - Definitions
  • § 53.040 - Written Communications
  • § 53.050 - Deliberate Misconduct
  • § 53.060 - Employee Protection
  • § 53.070 - Completeness and Accuracy of Information
  • § 53.080 - Specific Exemptions
  • § 53.090 - Combining Licenses; Elimination of Repetition
  • § 53.100 - Jurisdictional Limits
  • § 53.110 - Attacks and Destructive Acts
  • § 53.120 - Information Collection Requirements: OMB Approval 9

Subpart A - § 53.020 Definitions 10

  • Advanced nuclear plant o

Advanced nuclear plant [or facility] means a utilization facility consisting of one or more advanced nuclear reactors [as defined in NEIMA] and associated co-located support facilities, which may include one or more reactor modules, [using nuclear fission, nuclear fusion, or accelerator-driven reactor technologies] that are used for producing power for commercial electric or other commercial purposes. The advanced nuclear plant includes the collection of sites, buildings, radionuclide sources, and structures, systems, and components for which a license is being sought under this part.

Definition of advanced nuclear reactor (Nuclear Energy Innovation and Modernization Act (NEIMA))

o a nuclear fission or fusion reactor, including a prototype plant (as defined in sections 50.2 and 52.1 of title 10, Code of Federal Regulations (as in effect on the date of enactment of this Act)), with significant improvements compared to commercial nuclear reactors under construction as of the date of enactment of this Act, including improvements such as (A) additional inherent safety features; (B) significantly lower levelized cost of electricity; (C) lower waste yields; (D) greater fuel utilization; (E) enhanced reliability; (F) increased proliferation resistance; (G) increased thermal efficiency; or (H) ability to integrate into electric and nonelectric applications.

SECY-20-0032 o

The staff interprets NEIMAs definition of an advanced nuclear reactor, which states that such a reactor will have significant improvements compared to commercial nuclear reactors under construction as of January 14, 2019, as excluding Generation III+ designs from the definition because the AP1000 reactors were under construction at the time of NEIMAs enactment.

Subpart A - § 53.020 Definitions 11

  • Consensus code or standard o

means any technical standard (1) developed or adopted by a voluntary consensus standard body under procedures that assure that persons having interests within the scope of the standard that are affected by the provisions of the standard have reached substantial agreement on its adoption, (2) formulated in a manner that afforded an opportunity for diverse views to be considered, and (3) designated by the standards body as such a standard for the safe design, manufacture, construction, or operation of nuclear power plants.

Subpart A - § 53.020 Definitions 12

  • End state o

means the set of conditions at the end of an event sequence that characterizes the impact of the sequence on the plant or resulting releases of radionuclides to the environment. In most probabilistic risk assessments, end states typically include success states (i.e., those states with negligible impact) and release categories.

  • Event sequence o

means a postulated initiating event defined for a set of initial plant conditions followed by system, safety function, and operator successes or failures, and terminating in a specified end state depending on the system, safety function, and operator successes and failures (e.g., prevention of release of radioactive material or release in one of the reactor-specific release categories). An event sequence may include many unique variations of events (e.g., minimal cut sets) that are similar in terms of how they impact the performance of safety functions along the event sequence.

Subpart A - § 53.020 Definitions 13 Normal plant operation or normal operation o

means operations that are expected to occur during planned operations or shutdown of the reactor.

Licensing basis events (LBEs) mean a collection of event sequences considered in the design and licensing of the advanced nuclear plant. LBEs are unplanned events and include AOOs, unlikely event sequences, very unlikely event sequences, and DBAs.

Design basis accidents (DBAs) mean postulated event sequences that are used to set functional design criteria and performance objectives for the design of safety-related structures, systems, and components. DBAs are a type of licensing basis event and are based on the capabilities and reliabilities of safety-related structures, systems, and components needed to mitigate and prevent event sequences, respectively.

Anticipated operational occurrences (AOOs) o mean anticipated event sequences expected to occur one or more times during the life of a nuclear power plant. An event sequences with a mean frequency of 1x10-2/plant-year and greater is an AOO. AOOs take into account the expected responses of all SSCs within the plant, regardless of safety classification. AOOs are a type of licensing basis event. [Based, in part, on Appendix A to part 50.]

Subpart A - § 53.020 Definitions 14

  • Unlikely event sequences o

mean event sequences that have estimated frequencies below the frequency of AOOs. Unlikely event sequences are a subset of LBEs. [For example, within the licensing modernization project, this would equate to design basis events with a frequency range of between 1x10-2 and 5x10-4 per plant year with an accounting for uncertainties.]

  • Very unlikely event sequences o

mean event sequences that have estimated frequencies well below the frequency of events expected to occur in the life of an advanced nuclear plant. Very unlikely event sequences are a subset of LBEs. [For example, within the licensing modernization project, this would equate to beyond design basis events with a frequency range of between 1x10-4 and 5x10-7 per plant year with an accounting for uncertainties.]

Subpart A - § 53.020 Definitions 15

  • Safety-related (SR) o means those SSCs and human actions that warrant special treatment and are relied upon to demonstrate compliance with the safety criteria in § 53.210(b).
  • Non-Safety Related but Safety Significant (NSRSS) o means those SSCs and human actions that warrant special treatment and are not safety-related but are relied on to achieve defense-in-depth or perform risk-significant functions.
  • Non-Safety Significant (NSS) o means those SSCs not warranting special treatment, are not safety-related, and are not relied on to achieve adequate defense-in-depth or to perform risk-significant functions.

Subpart A - § 53.020 Definitions 16

  • Special treatment o

means those requirements, such as measures taken to satisfy functional design criteria, quality assurance, and programmatic controls, that provide assurance that certain SSCs will provide defense-in-depth or perform risk-significant functions and that provide confidence that the SSCs will perform under the service conditions and with the reliability assumed in the analysis performed in accordance with § 53.450 to provide reasonable assurance of meeting the safety criteria in § 53.210(b) and § 53.220(b).

  • Defense in depth o

means inclusion of multiple independent and redundant layers of defense in the design of a facility and its operating procedures to compensate for potential human and mechanical failures so that no single layer of defense, no matter how robust, is exclusively relied upon. Defense-in-depth includes, but is not limited to, the use of access controls, physical barriers, redundant and diverse key safety functions, and emergency response measures.

Subpart A - § 53.020 Definitions 17

  • Design features o

means the active and passive structures, systems, or components and inherent characteristics of those structures, systems or components that contribute to limiting the total effective dose equivalent to individual members of the public during normal operations and prevent or mitigate the consequences of unplanned events.

  • Inherent characteristic means an attribute of a design feature that has such a high degree of certainty in its performance that uncertainties need not be quantified.
  • Functional design criteria o

means requirements for the performance of SSCs. For safety-related SSCs, these criteria define requirements necessary to demonstrate compliance with first tier safety criteria in § 53.210(b).

For non-safety-related but safety-significant SSCs, these criteria define requirements necessary to meet the second tier safety criteria in § 53.220(b).

Subpart A - § 53.040 - § 53.120 Other Administrative Requirements 18

  • Subpart A consistent with Part 50 and currently includes bracketed references to existing requirements in Parts 50, 52, etc.
  • Intending to develop Part 53 with largely no pointers to Parts 50 and 52; this will require copying and pasting the Part 50 or 52 language into Part 53 instead of using pointers.
  • Subpart A will include many pointers to other sections of Part 53 that will be added in future iterations.

Subpart A - General Provisions Discussion 19

20 Subpart F - Operational Objectives

Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Operational Objectives Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 21

Subpart F - § 53.700 Operational Objectives 22

  • Licensee must:

o Define structures, systems, and components (SSCs) o Maintain capabilities and reliabilities of SSCs o Ensure plant personnel have adequate knowledge and skills to perform their assigned duties to support safety functions o Implement plant programs sufficient to ensure the performance of identified safety functions

Subpart F - § 53.710 Transition to Operation 23

  • Prepare a transition plan from construction to operations o Demonstrate the SR and NSRSS SSCs are appropriately constructed and capable to perform o Plant personnel are appropriately licensed and trained to perform safety functions o Programs, procedures and controls are implemented to support the safety functions

Subpart F - § 53.720 Maintaining Capabilities 24

  • Capabilities and reliability of SSCs, when combined with associated programmatic controls and human actions, provide reasonable assurance that the safety criteria defined in §§ 53.210(b) and 53.220(b) will be met.
  • Paragraph (a) defines controls for SR SSCs (technical specifications).
  • Paragraph (b) defines controls for NSRSS SSCs (reliability assurance and other special treatment).

Subpart F - § 53.720(a)

Technical Specifications (TS) 25 TS required to define conditions or limitations on SSCs to fulfill safety functions (§ 53.230) and first tier safety criteria (§ 53.210(b))

Inventories of radioactive materials Operating limits For each SSC classified as safety related Limiting Conditions for Operation Surveillance Requirements Design Attributes Administrative Controls Decommissioning First iteration does not include:

- Safety limits or associated limiting safety system settings

- Criteria for limiting conditions for operation Some stated preferences to use deterministic approaches may be better addressed within Part 50.

Subpart F - § 53.720(b)

Special Treatment of NSRSS SSCs 26 Configurations and special treatments for NSRSS SSCs ensure capabilities, availabilities, and reliabilities to satisfy second tier safety criteria (§ 53.210(b)).

Controls must:

Identify authorities and processes for configuration changes Describe means by which special treatments for each NSRSS SSC will be provided and maintained Controls for NSRSS SSCs needed to implement a performance-based approach used to gain operational flexibilities and as part of methods that include replacing the single-failure criterion with a probabilistic (reliability) approach.

Deterministic approaches with different supporting analysis, safety classification schemes, and design approaches (e.g., inclusion of the single failure criterion) may be better addressed within Part 50.

MEETING BREAK Meeting to resume in 45 minutes 27

Subpart F - § 53.730 Maintenance, Repair and Inspection 28 a) Develop a program to maintain and repair SR and Safety Significant SSCs.

b) Take appropriate corrective action when NSRSS SSCs do not meet special treatment requirements or performance goals.

c) Evaluate performance and preventive maintenance activities every 24 months.

d) Conduct risk-informed assessment of the impact and scope of any maintenance activities.

Subpart F - § 53.740 Design Control 29

operations, or other items related to plant safety during the design process and before implementing design or operational changes.

o Physical modifications, procedural changes, operator actions, maintenance activities, system reconfigurations, access modifications or restrictions, changes to the emergency plan and security plan or their implementation.

o Establish measures for the identification and control of interfaces among plant activities.

Subpart F - Operational Objectives Discussion 30

31 Subpart F - Programs

Part 53 General Layout Subpart A, General Provisions Subpart B, Technology-Inclusive Safety Objectives Subpart C, Design and Analysis Subpart D, Siting Requirements Subpart E, Construction and Manufacturing Requirements Subpart F, Requirements for Operation Programs Subpart G, Decommissioning Requirements Subpart H, Applications for Licenses, Certifications and Approvals Subpart I, Maintaining and Revising Licensing Basis Information Subpart J, Reporting and Administrative Requirements 32

Subpart F - § 53.800 Programs 33

  • Programs must be provided for each advanced nuclear plant such that, when combined with associated design features and human actions, the plant will satisfy the first and second tier safety criteria defined in §§ 53.210 and 53.220.

Subpart F - § 53.810 Radiation Protection 34

  • Implement a radiation protection program to limit occupational exposure in accordance with Part 20.
  • Limit exposure to the public.

o Develop procedures and remedial actions in an Offsite Dose Calculations Manual (ODCM).

o ODCM

Define methodology used in the calculation.

Contain radioactive effluent controls and environmental monitoring activities.

Annual Radiological Environmental Operating and Radioactive Effluent Release Reports.

Subpart F - § 53.820 Emergency Preparedness 35

  • Develop and implement an EP Program for operations that is commensurate with the risks posed by the licensing basis events as analyzed in accordance with § 53.450.

o Staff is developing preliminary proposed rule language for Part 53 in coordination with activities related to the Emergency Preparedness for Small Modular Reactors and Other New Technologies rulemaking.

Subpart F - § 53.830 Security Programs 36

  • Develop and implement security programs:

o Information security o Physical security o Cyber security o Access authorization o Material control and accounting Staff is planning to review security-related preliminary proposed rule language at a future public meeting.

Subpart F - § 53.840 Quality Assurance (QA) 37

  • Develop and execute a QA program (QAP):

o Define duties and responsibilities for QA of SSCs o Written QA manual o Written procedures

Qualified personnel

Procurement

Handling, shipping and storage of materials

Testing and inspection

Corrective action

Document and configuration control

Design control

Record keeping

Auditing o Document results of QA activities

MEETING BREAK Meeting to resume in 15 minutes 38

Subpart F - § 53.850 Integrity Assessment Program (IAP) 39

  • Develop and implement an IAP.
  • Monitor, evaluate and manage:

o Effects of aging on SR and NSRSS SSCs whose failure could affect performance of safety functions.

o Cyclic and transient loads are maintained within applicable design limits.

o Degradation related to chemical interactions, operating temperatures, irradiation, and other environmental factors to ensure the capabilities and reliabilities of SSCs satisfy the functional design criteria of §§ 53.410(b) and 53.420(b).

Subpart F - § 53.860 Fire Protection 40

  • Develop and implement a fire protection plan:

o Identify responsible parties and authorities o Outline plans for fire protection, detection, suppression capability, and limitation of damage o Administrative controls, personnel requirements, and suppression activities o Means to limit damage to SR and NSRSS SSCs

  • Specific features of program:

o SR and NSRSS SSCs designed to minimize effect of fires o Use noncombustible and fire-resistant materials wherever practical in facility o Appropriate capacity and capability o Design such that inadvertent operation does not impair SR SSCs

Subpart F - § 53.870 Inservice Testing (IST) and Inservice Inspection (ISI) 41

  • Develop programs for ISI and IST:

o ISI and IST includes codes and standards supplemented by risk insights o Testing and frequency done to maintain reliability of SSCs o Documented procedures

  • Perform baseline inspections prior to starting operations:

o Determine benchmarks o Develop acceptance criteria o Results provided to plant manager and determine need for corrective action

Subpart F - § 53.880 Criticality Safety Program 42

  • The program must address the requirements in 10 CFR 70.24 for maintaining a monitoring system capable of detecting a criticality, having emergency procedures, and providing radiation protection for plant workers.

A topic for discussion is whether the alternatives to 10 CFR 70.24 provided in 10 CFR 50.68, Criticality accident requirements, are appropriate and useful in Part 53.

Subpart F - § 53.890 Facility Safety Program (FSP) 43

  • Establish an FSP using a risk-informed, performance-based process to proactively identify new or revised hazards and performance issues.
  • Routinely evaluate potential hazards, operating experience, human actions, and programmatic controls.
  • Consider measures to mitigate or eliminate the resulting risks.

Subpart F - § 53.892 FSP Performance Criteria 44

  • Take measures to protect public health and minimize danger to life or property as may be reasonably achieved when considering costs.

o Assess risk reduction measures related to radionuclide release during normal operation.

o Assess risk reduction measures for contributors to the overall cumulative risk from unplanned events.

  • Certified designs/manufacturing licenses must also use change control from Subpart H.

Subpart F - § 53.894 FSP Plan 45

  • FSP must use written plan and address:

o Scope of facilities covered o

How FSP will be implemented o

How personnel will be trained in FSP o

Risk-informed hazard management program o

Technology assessment program o

Internal facility safety program assessment Note that staff is looking at the possibility that some of the administrative details in the first iteration language might be addressed within guidance documents.

Subpart F - § 53.896 Review, Approval, and Retention of FSP 46

  • FSP plan is part of the application
  • NRC to review/approve FSP plan
  • Will define staff process for reviewing FSP plan changes and amendments

Subpart F - § 53.900 Procedures and Guidelines 47

  • Integrated set of procedures and guidelines to maintain normal operations and respond to unplanned events
  • Plan must address:

o Plant operations o Maintenance under § 53.730 o Program requirements under this subpart (e.g., radiation protection, QA, Integrity Assessment) o Emergency operating procedures if human intervention required o Accident management guidelines

Subpart F: Programs Discussion 48

49 Discussion on Previously Released Subparts and Integration of Subparts

Previously Released Subparts 50

  • Previously Released Preliminary Proposed Rule Language o Subpart D, Siting o Subpart E, Construction and Manufacturing
  • Other Previously Released Preliminary Proposed Rule Language o Subpart B, Technology-Inclusive Safety Requirements o Subpart C, Design and Analysis

Previously Released Subparts Discussion 51

Final Discussion and Questions 52

Part 53 Rulemaking Schedule Milestone Schedule Major Rulemaking Activities/Milestones Schedule Public Outreach, ACRS Interactions and Generation of Proposed Rule Package Present to April 2022 (11 months)

Submit Draft Proposed Rule Package to Commission May 2022 Publish Proposed Rule and Draft Key Guidance October 2022 Public Comment Period - 60 days November and December 2022 Public Outreach and Generation of Final Rule Package January 2023 to February 2024 (14 months)

Submit Draft Final Rule Package to Commission March 2024 Office of Management and Budget and Office of the Federal Register Processing July 2024 to September 2024 Publish Final Rule and Key Guidance October 2024 53

Future Public Meetings The NRC staff will continue to host monthly public meetings, estimated to be the first Thursday of every month, to discuss and receive feedback on various regulatory topics and preliminary proposed rule text.

o The next Part 53 public meeting will be scheduled for June 3, 2021.

o The preliminary proposed rule text will be posted on regulations.gov under docket ID NRC-2019-0062 before the public meeting.

o The NRC staff is scheduled to meet with the ACRS Future Plants Subcommittee on May 20, 2021.

54

Closing Remarks Rulemaking Contacts Robert.Beall@nrc.gov 301-415-3874 William.Reckley@nrc.gov 301-415-7490 Regulations.gov docket ID: NRC-2019-0062 Please provide feedback on this public meeting using this link:

https://www.nrc.gov/public-involve/public-meetings/contactus.html 55

Acronyms and Abbreviations 56 ACRS Advisory Committee on Reactor Safeguards ADAMS Agencywide Document Access Management System AOO Anticipated operational occurrences CFR Code of Federal Regulations DBA Design basis accident EP Emergency preparedness FSP Facility Safety Program IAP Integrity Assessment Program ISI Inservice inspection IST Inservice testing LBE Licensing basis event NEI Nuclear Energy Institute NEIMA Nuclear Energy Innovation and Modernization Act NRC U.S. Nuclear Regulatory Commission NRR Office of Nuclear Reactor Regulation NSRSS Non-safety related but safety significant NSS Non-safety significant ODCM Offsite Dose Calculations Manual OMB Office of Management and Budget QA Quality assurance QAP Quality assurance program SAR Safety analysis report SR Safety related SSCs Structures, systems, and components TS Technical specifications UCNIC U.S. Nuclear Industry Council

Background Slides 57

First Principles 58 See: SECY-18-0096, Functional Containment Performance Criteria for Non-Light-Water-Reactors, and INL/EXT-20-58717, Technology-Inclusive Determination of Mechanistic Source Terms for Offsite Dose-Related Assessments for Advanced Nuclear Reactor Facilities

Integrated Approach Consequence Based Security EP for SMRs and ONTs Functional Containment Insurance and Liability Siting near densely populated areas Environmental Reviews Licensing Modernization Project 59

Part 53 Rulemaking 60 The Part 53 Rulemaking Process*

  • The process depicted in this schematic is unique to the Part 53 rulemaking and varies in some ways compared to a similar A Typical Rulemaking Process schematic available on the NRCs public website.

=

Background===

Nuclear Energy Innovation and Modernization Act (NEIMA; Public Law 115-439) signed into law in January 2019 requires the NRC to complete a rulemaking to establish a technology-inclusive, regulatory framework for optional use for commercial advanced nuclear reactors no later than December 2027 o

(1) ADVANCED NUCLEAR REACTORThe term advanced nuclear reactor means a nuclear fission or fusion reactor, including a prototype plant with significant improvements compared to commercial nuclear reactors under construction as of the date of enactment of this Act, 61