Summary of the August 17, 2020, Closed Meeting Between the U.S. Nuclear Regulatory Commission and the Pressurized Water Reactor Owners Group on a Conceptual Program for Temporary Relaxation of Ultimate Heat Sink Peak Temperature Surveillanc
ML21124A419
Person / Time
Site: 99902037
Issue date: 05/06/2021
From: Leslie Fields
Licensing Processes Branch
To: Dennis Morey
Licensing Processes Branch
Fields L
References
Download: ML21124A419 (4)


Text

May 6, 2021 MEMORANDUM TO:

Dennis C. Morey, Chief Licensing Processes Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:

Leslie C. Fields, Senior Project Manager /RA/

Licensing Processes Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE AUGUST 17, 2020, CLOSED MEETING BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND THE PRESSURIZED WATER REACTOR OWNERS GROUP ON A CONCEPTUAL PROGRAM FOR TEMPORARY RELAXATION OF ULTIMATE HEAT SINK PEAK TEMPERATURE SURVEILLANCE REQUIREMENT On August 17, 2020, the U.S. Nuclear Regulatory Commission (NRC) staff held a closed meeting with representatives from the Pressurized Water Reactor Owners Group (PWROG) to discuss a conceptual program for temporary relaxation of Ultimate Heat Sink (UHS) peak temperature surveillance requirement. The information discussed during the meeting was proprietary in nature, and therefore, the meeting was closed to the public. The meeting notice is publicly available in the Agencywide Documents Access and Management System (ADAMS) under Package Accession No. ML21124A421. The list of meeting attendees is enclosed.

Objective The objective of the meeting was to provide PWROG the opportunity to discuss a potential request to revise technical specifications (TS) 3.7.9, Ultimate Heat Sink (UHS). During the opening remarks PWROG representatives introduced the key contributors to present the details of the request. PWROG representatives also discussed: 1) the need for the proposed TS change, 2) the description of the change, and 3) the completion time needed to complete the revision. The meeting also provided an opportunity for PWROG to present a justification for continued operation and an evaluation of the containment analysis of record (AOR).

CONTACT: Leslie Fields, NRR/DORL 301-415-1186

Discussion To present the historical perspective, the PWROG stated that TS 3.7.9, Ultimate Heat Sink as described in NUREG-1430, Standard Technical Specifications - Babcock and Wilcox Plants, NUREG-1431, Standard Technical Specifications - Westinghouse Plants, and NUREG-1432, Standard Technical Specifications Combustion Engineering Plants, does not contain actions to restore the UHS temperature to within limit and requires a unit shutdown for the out of limit condition.

During the meeting, the PWROG representatives addressed how to handle conditions when water temperature of the UHS exceeds the regulatory limit. The PWROG representatives presented a description of the potential action to restore water temperature of the UHS to within regulatory limits and the necessary completion time. The TSs should specify a limiting condition for operation and state the actions to be taken if the UHS limiting condition for operation is temporarily unavailable during the operating modes. The PWROG representatives discussed adding an action to the TS 3.7.9 that contains a condition to address exceeding the UHS temperature limit, a required action to restore the UHS temperature to within limit, and the associated completion time.

Final Comments At the conclusion of the meeting, the PWROG representatives stated that it plans to determine if this request will be submitted as a topical report in the near future.

Docket No. 99902037

Enclosure:

List of Meeting Attendees

ML21124A421 (Package)

ML20218A835 (Notice)

ML21124A419 (Summary)

OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DORL/LLPB/BC NAME LFields DHarrison DMorey DATE 05/05/2021 05/6/2021 05/6/2021

Enclosure

SUMMARY

OF AUGUST 17, 2020, CLOSED MEETING ON A TEMPORARY RELAXATION OF ULTIMATE HEAT SINK PEAK TEMPERATURE SURVEILLANCE REQUIREMENT ATTENDANCE SHEET Name Organization E-mail Leslie Fields NRC leslie.fields@nrc.gov Dennis Morey NRC dennis.morey@nrc.gov Gregory Suber NRC gregory.suber@nrc.gov Robert Elliott NRC robert.elliott@nrc.gov Brian Wittick NRC brian.wittick@nrc.gov Gordon Curran NRC gordon.curran@nrc.gov Joel Wiebe NRC joel.wiebe@nrc.gov Joshua Kaizer NRC joshua.kaizer@nrc.gov Victor Cusumano NRC victor.cusumano@nrc.gov Chang Li NRC chang.li@nrc.gov Jennifer Tobin NRC jennifer.tobin@nrc.gov Steve Jones NRC steve.jones@nrc.gov Briana Grange NRC briana.grange@nrc.gov Clinton Ashley NRC clinton.ashley@nrc.gov Anthony Nowinowski Westinghouse nowinowa@westinghouse.com Stephen Swantner Westinghouse swantnsr@westinghouse.com James Andrachek Westinghouse andracjd@westinghouse.com Jay Boardman Westinghouse boardmjd@westinghouse.com Jordan Vaughan Duke Energy Jordan.Vaughan@duke-energy.com Terrence O'Brien Exelon terry.obrien@exeloncorp.com James Miksa Entergy jmiksa@entergy.com