Base Welded L (in)

W//OD (in)

T (in)

Total#

Types 9C-051 Pipe CS 12 1.031 13 Fabrication Flaws (LOF, CRK, IP, POR, SLG)

PNNL-24232 (NUREG/CR-7204)

UT-RT pipe from LMT PQ-31-DM-05 Pipe Segment SS/CS NorthAnna mock-up specimen PQ-31-DM-10 Pipe Segment SS/CS NorthAnna mock-up specimen 06-/9 Plate SS 14 4

0.6 100 0 200 Plate SS 16 4

0.63 2289-0-C108 Plate SS 10 4

0.6 2289-9-C102 Plate SS 12 4

0.6 2289-9-C111 Plate SS 12.1 4

0.6 2289-9-C112 Plate SS 12 15.75 0.6 2289-9-C113 Plate SS 12 4

0.6 2289-9-C114 Plate SS 12 3.9 0.56 Battelle 6349 Plate SS 6.7 3.9 0.65 CRDM #10 (split/etched)

CRDM Inconel split axially, 1 side etched CRDM #3 CRDM Inconel CRDM #5 (cal)

CRDM Inconel CRDM #6 CRDM Inconel CRDM #9 CRDM Inconel F87146 Plate SS 17.1 11.6 0.67 N10 S300 P10 Plate Al 8

4 1

P20 S300 N20 Plate Al 8

4 1

P35 S300 N35 Plate Al 8

3.75 1

P5 S300 N5 Plate Al 7.87 4

1.06 S100 S050 Plate Al 8

4 0.75 S500 S400 Plate Al 8

4 0.75 UT-RES-45-LAT-AL Plate Al 8.5 6.75 3

Plate Al 10 4

0.5 Plate CS 9.81 6.16 2.9 Peening Plates (x3)

Plate SS x3 14C-146 "Beast" Pipe SS CS 36 3.3 DMW 16C-148 Plate 304 SS 304 SS 16.81 24.02 0.5 4

TFC 304SS, single V with crown, flaws at toe AAD-1 Pipe Segment SS 36 NUREGCR-6929 AAD-3 Pipe Segment 304 CCSS 11.30 36 3.31 0

PNNL-11171 (NUREGCR-6594)

PNNL-23393

("SwRI" in NUREG/CR-6594)

B-505 Pipe Segment A351 CF8A (C)

A351 CF8A (E) 15.75 33.26 2.28 11 Notch, SDH PNNL-11171 (NUREGCR-6594)

PNNL-16292 (NUREGCR-6933)

Calibration Block B-519 Pipe Segment A351 CF8A (C)

A351 CF8A (E) 15.91 33.26 2.28 1

TFC PNNL-23393 PNNL-16292 (NUREGCR-6933)

CS ring cut of 14C-146 Pipe CS 36 cut scrap from 14C-146 Pipe Segment CS 36 IHI SW CASS Ring Pipe Segment CCSS 6

36 3.3 0

PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

Early/mid '60s Manoir-B (Cal/Res)

Pipe Segment SS 8.54 36 2.95 32 Notches, FBHs, SDHs cal and resolution machined reflectors Westinghouse Ring Pipe Segment CCSS 10 28 2.5 0

PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929) late-60s/mid-70s WSS cal Rolled Plate WSS 36 2.5 Notches, SDHs calibration notches and SDHs (PHTool)

Aaron_ship DMW Pipe SS/CS 14?

2?

DMW specimen, ID clad giant blocks x3 Plate x3, with lifting hooks ONP-D-2 Nozzle-SafeEnd-Pipe CS/WSS CCSS 24.25 36 2.9 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG ONP-D-5 Nozzle-SafeEnd-Pipe CS/WSS CCSS 24.25 36 2.9 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG OPE-5 Pipe-Elbow SCSS CCSS 20.5 36 2.8 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG "24-x66" Pipe Segment Al block Pipe Segment Al 36 Two different IDs B-504 Pipe Segment A351 CF8A (E)

A351 CF8A (C) 15.91 33.26 2.3 1

TFC PNNL-16292 (NUREGCR-6933)

B-615 Pipe Segment Clad CS Clad CS 36 2.67 0

HT-02291A Pipe Segment INE-A-1 Nozzle-SafeEnd-Elbow CS/WSS SCSS 24 36 2.9 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG INE-A-4 Nozzle-SafeEnd-Elbow CS/WSS SCSS 24 36 2.9 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG ONP-3-8 Nozzle-SafeEnd-Pipe CS/WSS CCSS 24.25 36 2.8 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG UT-13 Pipe Segment SS cal block "M.Good 6/18/93" Plate Copper 0

High-purity copper plate 196-202 Plate 4-pieces taped together Pipe Segment 0

Cubiod with flaw cut out from block. 4 pieces are what remains B-518 Pipe Segment SS 33.26

???

S300 Plate W-1 Pipe Segment Ferritic TFC W-2 Pipe Segment Ferritic TFC W-3 Pipe Segment Ferritic TFC Pipe Segment 36 Looks similar to a B-specimen Plate Plate Plate 2.29.84 EIH Plate B 2289 1101 B Plate Coupon #1 Plate Coupon #10 Plate Coupon #2 Plate Coupon #3 Plate hole pattern Coupon #6 Plate Coupon #8 Plate Coupon #9 Plate P8ABB Plate ring exgment Pipe Segment UT-RPT-CIRC-1 Repeatability Block CS 7.75 7

2.5 4

Machined Notchs NUREG\\CR-5985 Sup.1 UT-RPT-CIRC-AL Repeatability Block Al 7.75 7

2.5 3

Machined Notchs welded plate Plate Plate Plate angled holes Plate Al SDHs Plate welded-on frame for raised plate, top-surf holes/notches "Taylor" Pipe Segment Looks similar to a B-specimen B-508 Pipe Segment A351 CF8A (E)

A351 CF8A (C) 15.88 33.26 2.27 1

TFC PNNL-16292 (NUREGCR-6933)

B-509 Pipe Segment SS 15.75 33.26 2.34 1

B-513 Pipe Segment SS 15.75 33.26 2.35 1

B-520 Pipe Segment A351 CF8A (C)

A351 CF8A (E) 15.88 33.26 2.27 1

TFC PNNL-16292 (NUREGCR-6933)

B-549 Pipe Segment SS 33.26

???

carbon plate Plate CS E3-83 Pipe SS 4 welds INE-A-5 Nozzle-SafeEnd-Elbow CS/WSS SCSS 25 36 2.9 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG welded segment Pipe Segment Plate 522 Pipe Segment 36 "Taylor" Plate CS "Taylor" Pipe Segment SS 36 Looks similar to a B-specimen (Y-pattern Test Block)

Test Block Al 7

FBH NUREG\\CR-5985 NUREG\\CR-5985 Sup.1 6-82 Plate 7C-033 Plate Alloy 600 Alloy 600 26 5

3 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-034 Plate Alloy 600 Alloy 600 26 5

3.013 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-035 Plate Alloy 600 Alloy 600 26 5

3.007 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-036 Plate Alloy 600 Alloy 600 26 5

3 1

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-050 Plate Alloy 600 Alloy 600 26 5

3.008 1

Notch PNNL-14561 (NUREG/CR-7159) double-V weld B 2289 Plate Calibration for single wire cladded blocks cylinder Bar DGRP 40605 Plate SS Weld #12, DW1 Dogbones x3 Plate etched piece Plate SS Heavy Duty Engraving Tool Test Plate CS P8-A Plate plate Plate UT-RES-4560-2 Cal Block CS NUREG\\CR-5985 Sup.1 welded strip Pipe Segment long and thin Plate Al FBHs Pipe Segment Pipe Segment Pipe Segment CS 36 01N Pipe Segment 36 Assorted Small Metal B-609 (DNST)

Pipe Segment Clad Ferritic Clad Ferritic 36 2.40 0

NUREG/CR-5068 Destructively Analyzed (1/2-Specimen)

B-609 (UPST)

Pipe Segment Clad Ferritic Clad Ferritic 36 2.40 0

NUREG/CR-5068 Destructively Analyzed (1/2-Specimen)

P5BCBD Plate PWR T250 3 Plate "BNW" Plate SS mirror-image letters drilled

  1. 1 20%

Pipe Segment 4-pieces taped together Pipe Segment Cubiod with flaw cut out from block. 4 pieces are what remains B-502 Pipe Segment SS 15.75 33.26 2.36 1

bar & plates x4 South Top // South Bottom Pipe Assorted Medium Metal NINEMILE POINT ISI Pipe Segment SS "1"

Plate Assorted Small Metal M135 ("A135")

Plate H6517 Pipe welded to a plate TTD28262 Pipe Pipe edge prepped for welding 2 2045 Pipe 277-48-4175 SWT. 1B Pipe "R. Hebebrand U.A.S. 6/22/82" Pipe edge prepped for welding Pipe Copper?

"132" Plate Destructively Analyzed (1/2-Specimen)

"132" Plate Destructively Analyzed (1/2-Specimen)

"140" Plate Destructively Analyzed (1/2-Specimen)

"153" Plate Destructively Analyzed (1/2-Specimen)

Notes Reports Specimen ID Geometry Flaws Dimensions Material

"3" Plate "4"

Plate "A142" Plate Destructively Analyzed (1/2-Specimen)

"A143" Plate Destructively Analyzed (1/2-Specimen)

"A144" Plate Destructively Analyzed (1/2-Specimen)

"A155" Plate Destructively Analyzed (1/2-Specimen)

"A156" Plate Destructively Analyzed (1/2-Specimen)

"A156" Plate Destructively Analyzed (1/2-Specimen)

"B103" Plate Destructively Analyzed (1/2-Specimen)

?

Plate

?

Plate

?

Plate 10978 01 9 2 Plate 11 metal chunk large gouge cut out 2289 9 B106 Plate Destructively Analyzed (1/2-Specimen) 2289 9 B112 ("30-40")

Plate 2289 9 B117 ("B117")

Plate A155 Plate Destructively Analyzed (1/2-Specimen)

Al res block Plate Al Res holes M136 Plate M137 Plate M138 Plate M141 Plate Destructively Analyzed (1/2-Specimen)

M148 ("A148")

Plate Destructively Analyzed (1/2-Specimen)

M148 ("A148")

Plate Destructively Analyzed (1/2-Specimen)

M153 Plate Destructively Analyzed (1/2-Specimen)

M160 Plate Destructively Analyzed (1/2-Specimen)

M161 Plate Destructively Analyzed (1/2-Specimen)

Large Plates (x3)

Plate x3 Steel res block Plate 1201 Plate strip wire clad (should be documented) 1202 Plate Multi? (unverified) 1203 Plate Multi? (unverified)

"Taylor" Plate CS "Taylor" Plate CS pipe seg Pipe Segment plate Plate CS 1200 Plate Multi wire clad (should be documented) 1204 Plate Single? (unverified) 1205 Plate Single wire clad (should be documented) 41 A Plate B-511 Pipe Segment SS 33.26 0

Assorted Plate Plate SS B-605 (UPST)

Pipe Segment Clad Ferritic Clad Ferritic 2.66 0

NUREG/CR-5068 Destructively Analyzed (1/2-Specimen) blocks x3 Plate x3 B-606 Pipe Segment Clad CS Clad CS

???

B-608 Pipe Segment Clad CS Clad CS 0

B-610 Pipe Segment Clad CS Clad CS 15.73 36 2.67 1

B-634 Pipe Segment Clad CS Clad CS 15.86 36 2.67 1

pipe seg Pipe Segment CS Looks like a B-specimen pipe seg Pipe Segment CS Looks like a B-specimen pipe seg Pipe Segment CS Looks like a B-specimen Assorted Medium Metal Plate B-501 Pipe Segment A351 CF8A (C)

A351 CF8A (E) 15.92 33.26 2.3 1

TFC PNNL-16292 (NUREGCR-6933)

Crack added (by Trueflaw) after PISC-II B-515 Pipe Segment A351 CF8A (C)

A351 CF8A (E) 15.91 33.26 2.3 1

TFC PNNL-16292 (NUREGCR-6933)

B-517 Pipe Segment SS 15.75 33.26 2.34 1

B-528 Pipe Segment SS 15.75 33.26 2.34 1

"practice tube" Pipe B-617 (UPST)

Pipe Segment Clad Ferritic Clad Ferritic 36 2.69 0

NUREG/CR-5068 Destructively Analyzed (1/2-Specimen)

B-617 A (DNST)

Pipe Segment Clad Ferritic Clad Ferritic 36 2.69 0

NUREG/CR-5068 Destructively Analyzed (1/2-Specimen) block Plate "X" and "Y" stamps plate Plate plate Plate SK-3-26466 Pipe B-614 Pipe Segment 36 2.62 1

B-635 Pipe Segment 36 2.6 1

(B-613) 2 "1"

"4-4" "4-48" "resolution" CRDM #12 CRDM Inconel CRDM #2 CRDM Inconel CRDM flange vessel wall Vessel Wall Section Peening Plate (x1)

Plate Large-bore HDPE HDPE "4-6A" "4-6C" "5-10" "5-7DA" "5-7H" "5-9C" "CODH-2B" Vessel Wall Section "COHC-2" Vessel Wall Section Weld at center "COHC-2B" Vessel Wall Section "COHD-2A" Vessel Wall Section "Taylor" 5-214 CODB/CODC "SHOREHAM" Vessel Wall Section Steel Block steel block Steel Block vessel wall Vessel Wall Section vessel wall Vessel Wall Section vessel wall Vessel Wall Section vessel wall Vessel Wall Section vessel wall Vessel Wall Section 20346 "304SS-2" "304SS-3" "AAD-2" Pipe Segment 304 CCSS 14.45 36 0.26 0

PNNL-11171 (NUREGCR-6594)

PNNL-23393 8C-032 Nozzle-Safe-Pipe SA508 316/CASS TP304L 10.083 13.75 1.28 4

TFC PNNL-19018 Before and after MSIP 8C-036 Nozzle-Safe-Pipe SA508 316/CASS TP304L 10.083 13.75 1.28 6

TFC, HIPed EDM PNNL-19018 BMI specimen BMI NUREG/CR-7019 PINC 5.3 from KINS?? (nureg)

Machined CRDM specimen CRDM NUREG/CR-6996 Manoir-A (TrueFlaw)

Pipe Segment SS 8.54 36 2.95 2

TFC (grown) 086BCB1609 & 086BCB1609 Manoir-C Pipe Segment SS 8.54 36 2.95 0

P02862 SA 106 upper pipe section cut 1 Prz surge line cass rings for micro stucture analysis upper pipe section cut 2 Prz surge line cass rings for micro stucture analysis upper pipe section cut 3 Prz surge line cass rings for micro stucture analysis upper pipe section cut 4 Prz surge line cass rings for micro stucture analysis upper pipe section cut 5 Prz surge line cass rings for micro stucture analysis HDPE (J3/5, J4/6.)

HDPE First round (discarded poorly made/documented)

J1, J2, J8 HDPE Pipe DR11 PE4710 HDPE Butt Fusion Joint 12.75 1.159 J28, J31, RJ4/RJ6, RJ4/RJ6-2, RJ8 HDPE Pipe DR11 PE4710 HDPE Butt Fusion Joint 12.75 1.159 many PNNL-26370_HDPE-TLR_041017 5 welds J29, J30 HDPE Pipe DR11 PE4710 HDPE Butt Fusion Joint 12.75 1.229 many tungsten particles PNNL-26370_HDPE-TLR_041017 2 welds J3/J5 HDPE Pipe DR11 PE4710 HDPE Butt Fusion Joint 12.75 1.229 J4/J6, J7 HDPE Pipe DR11 PE4710 HDPE Butt Fusion Joint 12.75 1.229 "4-5BBA" "4-5BBA" "5-613 Weld" Vessel Wall Section "P5AB" "RB-04-BAC" "RB-08-BAB" 4-3B 4-3E 4-5BA 4-5DA Assorted CS blocks Assorted Metal Assorted SS Plates P8ABA PNNL 5-6 Vessel Wall Section CS SS pipes x2 UT-RES 0000-2 Resolution Block 8

7.5 4

25 FBH NUREG\\CR-5985 NUREG\\CR-5985 Sup.1 02-24-15 seg1 Pipe Segment 304 SS 304 SS 21.813 24.25 1.42 5

TFC, Saw PNNL-19353 (NUREG/CR-7113) 02-24-15 seg2 Pipe Segment 304 SS 304 SS 21.813 24.25 1.42 4

TFC, Saw PNNL-19353 (NUREG/CR-7113)

"109 2DF" "109 5BC" "5-12A" "5-1AB" "5-7DD" "5-9A" "Steve Doctor" Pipe 700-375 Rings Assorted SS Plates Carbon Triangle Disk with Notches Nozzle dropout from vessel. Have paper published in 70's. Used to acess techniques to detect saw cuts. May have thermal fatigue.

K-5994 Pipe SS/CS nozzle-to-safe end DMW Surgeline Elbow

??

Plate 7C-005 Plate 304 WSS 304 WSS 15.5 10 2

2 TFC, Weld-repair double-V weld 7C-006 Plate 304 WSS 304 WSS 15.5 10 2

2 TFC double-V weld 7C-016 Plate 304 WSS 304 WSS 17.952 10 2.01 0

PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-017 Plate 304 WSS 304 WSS 18 10 2

0 PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-018 Plate 304 WSS 304 WSS 18 10 2

0 PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-021 Plate 304 WSS 304 WSS 18 10 2.033 0

PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-022 Plate 304 WSS 304 WSS 18 10 2.016 1

Notch PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-024 Plate 304 WSS 304 WSS 18 10 2.03 2

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-025 Plate 304 WSS 304 WSS 18 10 2

1 Notch PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-028 Plate 304 WSS 304 WSS 18 10 2.034 3

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-046 Plate 304 WSS 304 WSS 18 10 2.09 1

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-047 Plate 304 WSS 304 WSS 18 10 2.09 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-049 Plate 304 WSS 304 WSS 18 10 2.096 2

TFC PNNL-14561 (NUREG/CR-7159)

K weld CRDM Tubes (x4)

CRDM Inconel CS-02-01 Plate 304 WSS 304 WSS 14.17 9.84 2

6 TFC, Notch, SDH PNNL-14561 (NUREG/CR-7159) single-V weld CS-02-02 Plate 304 WSS 304 WSS 14.17 9.84 2

6 TFC, Notch, SDH PNNL-14561 (NUREG/CR-7159) single-V weld CS-02-03 Plate 304 WSS 304 WSS 14.17 9.84 2

5 Notch, SDH PNNL-14561 (NUREG/CR-7159) double-V weld CS-02-04 Plate 304 WSS 304 WSS 14.17 9.84 2

5 Notch, SDH PNNL-14561 (NUREG/CR-7159) double-J weld CS-02-05 Plate 304 WSS 304 WSS 14.17 9.84 2

7 Notch, SDH PNNL-14561 (NUREG/CR-7159)

K weld D-70411A Plate "B212" Pipe May have 360° flaw "B217" Pipe May have 360° flaw "C1A" UT in lieu of RT Specimen "C1C" UT in lieu of RT Specimen "C2A" UT in lieu of RT Specimen "COEB // COEC" Vessel Wall Section "D101" Pipe May have 360° flaw "D105" Pipe May have 360° flaw "D-2" Pipe 12.75 0.75 May have 360° flaw "D-3" Pipe 12.75 0.75 May have 360° flaw "D-4" Pipe 12.75 0.75 "EPRI 109-4" Not NRC, belongs to EPRI. Not sure if they want it back but we should keep until we get an answer from them.

"Phase IIa-SS" "SHOREHAM" 4-5A Assorted Pallet Metal Assorted Pipe Segments Assorted Plate Metal Assorted Vessel Wall B-18 Dogbones dogbones (small) x2 HC 1DA1 HC 1DA3 HC303DC HC303DC1 PNL EIH LTS RB 04 W1C RB 04 W1C RB 04 W2C RB 04 W2E RB11W1 D 3C-022 Pipe 304 SS 304 SS 42.8 24 1.4 8

Notch, TFC PNNL-19353 (NUREG/CR-7113)

Spanish spool piece SS 34 2.5 PNNL-16292 (NUREGCR-6933)

Fine grain, equiaxed microstructure on loan from EPRI 10C-011 Pipe-Nozzle A351 CF8M CS 26.938 12.75 1.34 5

TFC PNNL-21502 DMW, FSWOL 714.73 785-204 CODE# M-5336-1 Pipe-Nozzle DMW, FSWOL 8C-091 Pipe-Nozzle CASS CS 12.75 1.55 4

TFC, HIPed EDM PNNL-19018 9C-002 Pipe-Elbow A351 CF8M (CCSS)

A351 CF8M (SCSS) 30 12.75 1.25 6

TFC (imp., grown)

PNNL-19497 (NUREG/CR-7122)

PZR Pipe-Elbow (Sch. 160) 7C-059 Pipe-Elbow A351 CF8M (CCSS)

A351 CF8M (SCSS) 18 12.75 1.25 4

TFC PNNL-19497 (NUREG/CR-7122)

PZR Pipe-Elbow (Sch. 160) 9C-001 Pipe-Elbow A351 CF8M (CCSS)

A351 CF8M (SCSS) 30 12.75 1.25 3

TFC PNNL-19497 (NUREG/CR-7122)

PZR Pipe-Elbow (Sch. 160)

C3B (x2 halves)

Pipe Segment CS CS UT in lieu of RT Specimen CB1 CBC15 CBC7 CBC14 Pipe CS CS UT in lieu of RT Specimen "C2B" Pipe CS CS UT in lieu of RT Specimen "C5A" Pipe CS CS UT in lieu of RT Specimen "C5B" Pipe CS CS UT in lieu of RT Specimen C65 CBC3 CBC13 Pipe CS CS UT in lieu of RT Specimen CBC10 Pipe CS CS UT in lieu of RT Specimen CBC7 C3C Pipe CS CS UT in lieu of RT Specimen CBC8 C2C Pipe CS CS UT in lieu of RT Specimen pipe Pipe SS pipe Pipe CS CS UT in lieu of RT Specimen pipe Pipe SS SS tubes (x4)

Eastman Pipe-Halves (Crate)

"109-3" Vessel Wall Section CS "COGB// COGC" Vessel Wall Section CS "RB-08-BA" Vessel Wall Section CS vessel wall Vessel Wall Section CS vessel wall Vessel Wall Section CS "Aaron Ship Polish" Pipe SS "RB-02-BB" Vessel Wall Section CS "RB-06-BB" Vessel Wall Section CS Other end is "-BA" "RB-07-BA" Vessel Wall Section CS "RB-10-BB" Vessel Wall Section CS "RB-12-BB" Vessel Wall Section CS Other end is "-BA" 591-50 Pipe Segment SS CS block Block SS pipe seg Pipe Segment SS CS B/D-specimen?

WSS resolution Rolled Plate WSS 36 2.5 FBHs resolution holes (PHTool)

"B211" Pipe WSS WSS 11 TFC 10" Sch80 "B215" Pipe WSS WSS 4

TFC 10" Sch80 "B216" Pipe WSS WSS 10 TFC 10" Sch80 "D-5" Pipe (3C-022??)

Pipe w/ 3 Welds (B/D-specimen?)

Pipe Lots of scribe marks on inner lip, B/D-specimen?

(B/D-specimen?)

Pipe B/D-specimen?

(B/D-specimen?)

Pipe B/D-specimen?

(B/D-specimen?)

Pipe B/D-specimen?

(B/D-specimen?)

Pipe B/D-specimen?

HEAT NO 30245 Pipe B/D-specimen?

MOE 3 Z 1235 BTIN 7081 CF Pipe As-cast surface, Manoir Leftovers W1 Pipe 5

VT Plate 304SS 9

11 0.185 ensitive Info 6

VT Plate 304SS 9

11 0.185 ensitive Info 7

VT Plate 304SS 9

11 0.185 ensitive Info 8

VT Plate 304SS 9

11 0.185 ensitive Info 9

VT Plate 304SS 9

11 0.185 ensitive Info 10 VT Plate 304SS 9

11 0.185 ensitive Info 11 VT Plate 304SS 9

11 0.185 ensitive Info 12 VT Plate 304SS 9

11 0.185 ensitive Info 13 VT Plate 304SS 9

11 0.185 ensitive Info 14 VT Plate 304SS 9

11 0.185 ensitive Info 15 VT Plate 304SS 9

11 0.185 ensitive Info 16 VT Plate 304SS 9

11 0.185 ensitive Info 17 VT Plate 304SS 9

11 0.185 ensitive Info 18 VT Plate 304SS 9

11 0.185 ensitive Info 19 VT Plate 304SS 9

11 0.185 ensitive Info 20 VT Plate 304SS 9

11 0.185 ensitive Info 21 VT Plate 304SS 9

11 0.185 ensitive Info 22 VT Plate 304SS 9

11 0.185 ensitive Info 23 VT Plate 304SS 9

11 0.185 ensitive Info 24 VT Plate 304SS 9

11 0.185 ensitive Info 25 VT Plate 304SS 9

11 0.185 ensitive Info 26 VT Plate 304SS 9

11 0.185 ensitive Info 27 VT Plate 304SS 9

11 0.185 ensitive Info 28 VT Plate 304SS 9

11 0.185 ensitive Info 29 VT Plate 304SS 9

11 0.185 ensitive Info 30 VT Plate 304SS 9

11 0.185 ensitive Info APE-1 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 24 36 3.5/2.6 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG APE-4 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 24 36 3.5/2.6 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG B39 VT Plate SS 9

11 0.185 ensitive Info B40 VT Plate SS 9

11 0.185 ensitive Info B41 VT Plate SS 9

11 0.185 ensitive Info B42 VT Plate SS 9

11 0.185 ensitive Info B43 VT Plate SS 9

11 0.185 ensitive Info B44 VT Plate SS 9

11 0.185 ensitive Info B45 VT Plate SS 9

11 0.185 ensitive Info B46 VT Plate SS 9

11 0.185 ensitive Info B47 VT Plate SS 9

11 0.185 ensitive Info B48 VT Plate SS 9

11 0.185 ensitive Info B49 VT Plate SS 9

11 0.185 ensitive Info MPE-3 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 24 36 3.3/2.6 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG MPE-6 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 24 36 3.3/2.6 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG ONP-3-5 Outlet Nozzle-to-Safe End - to-Pipe CS (Nozzle)

Forged SS (Safe End) 24 36 2.6/2.8 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG OPE-2 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 20.5 36 2.8/2.3 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG OPE-5 Elbow to Pipe SCSS (Elbow)

CCSS (Pipe) 20.5 36 2.8/2.3 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG POP-7 Pump Outlet Nozzle-to-Pipe SCSS (Nozzle)

CCSS (Pipe) 21 36 3.3/2.6 1

MFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG

POP-8 Pump Outlet Nozzle-to-Pipe SCSS (Nozzle)

CCSS (Pipe) 21 36 3.3/2.6 1

TFC PNNL-16292 (NUREGCR-6933)

PNNL-16253 (NUREGCR-6929)

PWROG VT-LB-247 VT Plate Sensitive Info VT-LB-248 VT Plate Sensitive Info VT-LB-251 VT Plate Sensitive Info VT-LB-252 VT Plate Sensitive Info VT-SB-241 VT Plate Sensitive Info VT-SB-242 VT Plate Sensitive Info VT-SB-244 VT Plate Sensitive Info VT-SB-245 VT Plate Sensitive Info 02-12-34 Pipe Segment TP321 Aust.

TP321 Aust.

16 12.75 0.688 3

TFC Sch. 80 02-12-35 Pipe Segment TP321 Aust.

TP321 Aust.

18 12.75 0.5 3

TFC Sch. 80 02-12-36 Pipe Segment TP321 Aust.

TP321 Aust.

16 12.75 0.688 4

TFC Sch. 80 02-12-37 Pipe Segment TP321 Aust.

TP321 Aust.

24 12.75 0.5 4

TFC Sch. 80 02-24-15 seg3 Pipe Segment 304 SS 304 SS 21.813 24.25 1.42 4

TFC, Saw PNNL-19353 (NUREG/CR-7113)09-169 PNNL-16292 (NUREG/CR-6933)

?

201-758 Pipe-Elbow A351 CF8M (CCSS) elbow-to-pipe (Calvert Cliffs) 202-758 Pipe-Elbow A351 CF8M (CCSS) elbow-to-pipe (Calvert Cliffs) 79-38379-0 Elbow-Pipe A351 CF8M(CCSS) 0 PNNL-24232 (NUREG/CR-7204)

Calvert Cliffs 7C-019 Plate 304 WSS 304 WSS 18 10 2.03 0

PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-020 Plate 304 WSS 304 WSS 18 10 2.03 0

PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-023 Plate 304 WSS 304 WSS 18 10 2.03 2

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-026 Plate 304 WSS 304 WSS 18 10 2

3 Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-027 Plate 304 WSS 304 WSS 18 10 2.04 3

Notch PNNL-14561 (NUREG/CR-7159) double-V weld 7C-029 Plate 304 WSS 304 WSS 18 10 2.017 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-030 Plate 304 WSS 304 WSS 18 10 2.038 2

TFC PNNL-14561 (NUREG/CR-7159) double-V weld 7C-031 Plate 304 WSS 304 WSS 18 10 2.038 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-032 Plate 304 WSS 304 WSS 18 10 2.013 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 7C-048 Plate 304 WSS 304 WSS 18 10 2.037 1

TFC PNNL-14561 (NUREG/CR-7159) double-V weld, weld crown 96-SS-01 Plate 304 SS 9.5 4.2 0.75 1

TFC 9C-003 Nozzle-Safe-Pipe A106B 316/CASS 14 1.406 7

TFC PNNL-20853 PZR surge nozzle, MSIP 9C-023 Pipe-Nozzle SS CS 14.32 1.42 4

TFC PNNL-19018 DMW Shutdown cooling pipe 9C-034 Pipe-Nozzle A351 CF8M 516 Gr70 23.92 12.813 1.28 4

TFC PNNL-19018 PNNL-21502 DMW, FSWOL DP2-A39 Pipe-Elbow SS pipe-to-elbow PNL RDCS Plate CS 6

4 0.5 3

MFC PNL 07-343 C/S PNL RDSS Plate SS 6

4 0.5 3

MFC PNL 07-343 S/S pipe with DE-holes Pipe SS SS 12.5 pipe with DE-holes Pipe SS SS 12.5 pipe with DE-holes Pipe SS SS 12.5 CS Pipe Pipe CS Assorted specimens Assorted RPV Sections Vessel Wall Section CS D7C20 Pipe SS 33 24.5 1.5 A-106 Pipe Segment CS 49 24 2.5

Base Welded L (in)

W//OD (in)

T (in)

Total#

Types x2 HDPE Pipe Material HDPE Pipe HDPE 12.25 0

Raw Material x18 HDPE Pipe Material HDPE Pipe HDPE 60 12.5 0

Raw Material x3 SS pipe Pipe SS 55 14 1.5 0

Raw Material x2 Nozzle CS 16.5 11.25 0

Raw Material x4 BMI BMI CS 8.5 8.5 3

0 Raw Material x2 RPV sections Vessel Wall Section CS 21 21 6.25 0

Raw Material RPV sections Vessel Wall Section CS 42 21 6.25 0

Raw Material mounted instrument tube CS 0

Raw Material x10 Assorted RPV Sections Vessel Wall Section CS 0

Raw Material Assorted Scrap 0

Raw Material x19 Assorted RPV Sections Vessel Wall Section CS 0

Raw Material RPV section Vessel Wall Section CS 84 114 6.5 0

Raw Material RPV section Vessel Wall Section CS 117 6.5 0

Raw Material CS Pipe Pipe CS 209 24 0

Raw Material x2 Clad CS Pipes Pipe CS 37 3.5 0

Raw Material x6 CRDMs CRDM Inconel CS 32-45 0

Raw Material x5 CRDM flanges CRDM SS 23 0

Raw Material x11 CASS Surgeline Pipe SS 24.75-61 12.5 0

Raw Material x7 CS plates Plate CS 24 24 0

Raw Material x2 half-pipe ssections Pipe CS 36 0

Raw Material Clad Pipe w/ Nozzle Pipe CS 29.75 37 0

Raw Material CS Pipe Pipe CS 88 50 4.5 0

Raw Material CS Pipe Pipe CS 88 36 3.5 0

Raw Material x12 RPV sections Vessel Wall Section CS 48 50 10 0

Raw Material CS elbow Pipe CS 88 50 4

0 Raw Material x2 CS Pipe Pipe CS 77-88 37 3.5 0

Raw Material upper head penetration CS 50.5 49 10 0

Raw Material x3 SS pipe Pipe SS 28.5-81 24 1.5 0

Raw Material SS pipe Pipe SS 151 14 1.5 0

Raw Material RPV section Vessel Wall Section CS 83 158 6

0 Raw Material RPV section with BMIs CS 72 76 8

0 Raw Material CS segment CS 52 26 12.5 0

Raw Material x7 Assorted RPV pieces Vessel Wall Section CS 0

Raw Material x3 CS plates Plate CS 49-72 48 2

0 Raw Material 7030AC Plate SS 73 19.5 1

0 Raw Material CS Pipe Pipe CS 0

Raw Material RPV section Vessel Wall Section CS 61 47 8

0 Raw Material Reports Notes Qty Specimen ID Geometry Material Dimensions Flaws