Calculation Cover Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
1 of 190
- 5. Summary Description This calculation presents the criticality analysis of the HalfPACT package with the following payloads: 1) Two SC-30G2 shielded containers; 2) One SC-30G3 shielded container; 3) Two SC-55G1 shielded containers; and 4) One SC-55G2 shielded container. Two scenarios are considered 1) 325 FGE 239Pu with manually-compacted waste with less than 1 wt% beryllium, and
- 2) 245 FGE 239Pu with machine-compacted waste with less than 1 wt% beryllium. The most reactive condition is below the USL, and a CSI of zero is justified.
- 6. Software Usage Software Name Version
- 1. SCALE 6.2.3
- 2.
- 3.
- 4.
- 7. Preparer Name Signature Date Charles Henkel
- 8. Independent Reviewer(s)
Name Signature Date Sandra Larson Kyle Moyant
- 9. Project Representative Name Signature Date Scott Burns
- 10. QA Representative Name Signature Date Steve Tanner
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
2 of 190 TABLE OF CONTENTS
1.0 INTRODUCTION
................................................................................................................ 7 2.0 METHODOLOGY.............................................................................................................. 8 2.1 Description of Criticality Design........................................................................................ 8 2.1.1 Design Features........................................................................................................... 8 2.1.2 Summary Table of Criticality Evaluation................................................................... 8 2.1.3 Criticality Safety Index............................................................................................... 9 2.2 Fissile Material Contents.................................................................................................... 9 2.3 General Considerations..................................................................................................... 12 2.3.1 Model Configuration................................................................................................. 12 2.3.2 Material Properties.................................................................................................... 16 2.3.3 Computer Codes and Cross-Section Libraries.......................................................... 16 2.3.4 Demonstration of Maximum Reactivity.................................................................... 16 2.4 Payload Configurations..................................................................................................... 18 3.0 RESULTS........................................................................................................................... 19 3.1 Configuration Results....................................................................................................... 19 3.1.1 Configuration A0 - No Shielded Container.............................................................. 20 3.1.2 Configuration A1 - One SC-30G3 or SC-55G2 Container with Sphere Inside........ 21 3.1.3 Configuration A2 - Two SC-30G2 or SC-55G1 Containers with Sphere Inside..... 23 3.1.4 Configuration B2 - Two SC-30G2 or SC-55G1 Containers with Sphere Between the Containers.................................................................................................................. 25 3.1.5 Configuration C1 - One SC-30G3 or SC-55G2 Container with Sphere Outside at Top Corner................................................................................................................ 26 3.1.6 Configuration C2 - Two SC-30G2 or SC-55G1 Containers with Sphere Outside and in Contact with Both Containers............................................................................... 27 3.1.7 Configuration D1 - One SC-30G3 or SC-55G2 Container with Sphere Outside at Bottom Corner........................................................................................................... 28 3.1.8 Configuration E2 - Two SC-30G2 or SC-55G1 Containers with Sphere Inside Outermost Container................................................................................................. 29 3.2 Case G - 325 FGE - Manual Compaction........................................................................ 33 3.3 Case H - 245 FGE - Machine Compaction...................................................................... 35 4.0 BENCHMARK EVALUATIONS.................................................................................... 37 4.1 Applicability of Benchmark Experiments........................................................................ 37 4.2 Bias Determination........................................................................................................... 39
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
3 of 190 4.3 AoA Margin...................................................................................................................... 46 4.3.1 Beryllium Reflector................................................................................................... 46 4.3.2 Lead Reflector........................................................................................................... 48 4.4 USL Determination........................................................................................................... 49
5.0 REFERENCES
................................................................................................................... 50 6.0 APPENDIX......................................................................................................................... 51 6.1 Sample Models.................................................................................................................. 51 6.2 List of Files on Attachment 1............................................................................................ 54
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
4 of 190 LIST OF TABLES Table 2-1 Summary of Criticality Evaluation.............................................................................9 Table 2-2 Case G Fissile Sphere Parameters and Number Densities........................................12 Table 2-3 Case H Fissile Sphere Parameters and Number Densities........................................12 Table 2-4 Geometric Model Parameters for the Shielded Containers.......................................15 Table 2-5 Payload Configurations.............................................................................................18 Table 3-1 Results for Configuration A0....................................................................................20 Table 3-2 Results for Configuration A1 with Sphere Inside SC-30G3 Container....................21 Table 3-3 Results for Configuration A1 with Sphere Inside SC-55G2 Container....................22 Table 3-4 Results for Configuration A2 with Sphere Inside SC-30G2 Container....................23 Table 3-5 Results for Configuration A2 with Sphere Inside SC-55G1 Container....................24 Table 3-6 Results for Configuration B2 with Sphere Between SC-30G2 and SC-55G1 Containers.................................................................................................................25 Table 3-7 Results for Configuration C1 with Sphere Outside of SC-30G3 and SC-55G2 Containers.................................................................................................................26 Table 3-8 Results for Configuration C2 with Sphere Outside SC-30G2 and SC-55G1 Containers.................................................................................................................27 Table 3-9 Results for Configuration D1 with Sphere Outside SC-30G3 and SC-55G2 Containers.................................................................................................................28 Table 3-10 Results for Configuration E2 with Sphere Inside SC-30G2 Containers...................29 Table 3-11 Results for Configuration E2 with Sphere Inside SC-55G1 Containers...................31 Table 3-12 Results for Most Limiting Case at Various H/Pu Ratios and Reflector Volume Fractions....................................................................................................................33 Table 3-13 Case G Summary of Maximum Reactivity Results for each Shielded Container....34 Table 3-14 Most Limiting Case G Model with and without 1% (by vol) Beryllium in Moderator..................................................................................................................34 Table 3-15 Case H Summary of Maximum Reactivity Results for each Shielded Container....36 Table 3-16 Most Limiting Case H Model with and without 1% (by vol) Beryllium in Moderator..................................................................................................................36 Table 4-1 Benchmark Experiments Utilized.............................................................................38 Table 4-2 Normality Test Results.............................................................................................40 Table 4-3 Benchmark Experiments Results..............................................................................41 Table 4-4 Experiments with and without Beryllium Reflector.................................................47 Table 4-5 Experiments with and without Lead Reflector.........................................................48
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
5 of 190 Table 4-6 Calculation of USL...................................................................................................49 LIST OF FIGURES Figure 2-1 NCT Single Package Model......................................................................................14 Figure 2-2 HAC Single Package Model.....................................................................................15 Figure 3-1 Configuration A0 at Center and 45° Corner Locations............................................20 Figure 3-2 Configuration A1 with SC-30G3 Container at Center and Corner Locations -
Sphere in Corner.......................................................................................................21 Figure 3-3 Configuration A1 with SC-55G2 Container at Center - Sphere in Center and Side Locations...........................................................................................................22 Figure 3-4 Configuration A2 with SC-30G2 Container at Center Location - Sphere in Corner and Side Locations........................................................................................23 Figure 3-5 Configuration A2 with SC-55G1 Container at Center Location - Sphere in Corner and Center Locations....................................................................................24 Figure 3-6 Configuration B2 with SC-30G2 and SC-55G1 Containers at Center Location......25 Figure 3-7 Configuration C1 with SC-30G3 and SC-55G2 Containers at Corner Location -
Sphere Outside at Top of Container..........................................................................26 Figure 3-8 Configuration C2 with Containers SC-30G2 at 0° and SC-55G1 at 45° at Corner Location - Sphere Outside and in Contact with Both Containers............................27 Figure 3-9 Configuration D1 with Containers SC-30G3 and SC-55G2 at Corner Location -
Sphere Outside at Bottom of Container....................................................................28 Figure 3-10 Configuration E2 with SC-30G2 Containers at Corner Location - Fully Reflected and Air Reflected Cases...........................................................................29 Figure 3-11 Configuration E2 with SC-30G2 Containers at 45° at Corner Location - Air Reflected and SC/ICV Reflected Cases....................................................................30 Figure 3-12 Configuration E2 with SC-55G1 Containers at Corner Location - Fully Reflected and Air Reflected Cases...........................................................................31 Figure 3-13 Configuration E2 with SC-55G1 Containers at 45° at Corner Location - Air Reflected and SC/ICV Reflected Cases....................................................................32 Figure 4-1 Normalized keff Values for the Pu Benchmark Set...................................................40 Figure 4-2 Calculated keff Values for the Be-reflected 233ST015 Benchmark Set Compared to non-Be Average....................................................................................................46
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
6 of 190 TABLE OF REVISIONS Revision Number Pages Affected Revision Description 0
All New Issue
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
7 of 190
1.0 INTRODUCTION
Four shielded container (SC) assemblies, the SC-30G2, SC-30G3, SC-55G1 and SC-55G2, containing remote-handled transuranic (RH-TRU) material are evaluated in the HalfPACT package. Two payloads are considered: (1) manually compacted (i.e., not machine compacted) waste with <1% Be by mass, and (2) machine compacted waste with <1% Be by mass. A maximum 325 fissile gram equivalent (FGE) of 239Pu is justified for manually compacted waste, while a lower limit of 245 FGE is justified for machine compacted waste. The methodology and assumptions utilized in the existing HalfPACT Safety Analysis Report (SAR) [6] is also utilized in this analysis. The following analyses demonstrate that these configurations comply with the requirements of 10 CFR §71.55 and §71.59. The criticality safety index, per 10 CFR §71.59, is zero.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
8 of 190 2.0 METHODOLOGY 2.1 Description of Criticality Design 2.1.1 Design Features No special design features are required to maintain criticality safety, and no poisons are utilized in the package. The separation provided by the HalfPACT is sufficient to maintain criticality safety.
2.1.2 Summary Table of Criticality Evaluation The upper subcritical limit (USL) for ensuring that the HalfPACT is acceptably subcritical, as determined in Section 4.0, is:
USL = 0.9375 The package is considered to be acceptably subcritical if the computed ksafe (ks), which is defined as keffective (keff ks = keff
< USL The USL is determined on the basis of a benchmark analysis and incorporates the combined effects of code computational bias, the uncertainty in the bias based on benchmark-model uncertainties, and an administrative margin. The results of the benchmark analysis indicate that the USL is adequate to ensure subcriticality of the package.
Fully flooded conditions are utilized in both the normal conditions of transport (NCT) and hypothetical accident condition (HAC) models. Cases are developed both for manually compacted and machine compacted waste. Manually compacted waste models utilize 325 FGE 239Pu and reflector material composed of 25% polyethylene, 1% beryllium, and 74% water (by volume). Machine compacted waste models utilize 245 FGE 239Pu and reflector material composed of 99% polyethylene and 1% beryllium (by volume).
The maximum results of the criticality calculations are summarized in Table 2-1. The maximum calculated ks under HAC is 0.93616, which occurs for the optimally moderated HAC array package model with manually compacted waste.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
9 of 190 Table 2-1 Summary of Criticality Evaluation Limit Case G 325 FGE Manually Compacted Waste Case H 245 FGE Machine Compacted Waste Normal Conditions of Transport (NCT) ks ks Single Unit Maximum 0.93385 0.92958 Infinite Array Maximum 0.93475 0.92985 Hypothetical Accident Conditions (HAC) ks ks Single Unit Maximum 0.93425 0.92955 Infinite Array Maximum 0.93616 0.93039 USL = 0.9375 2.1.3 Criticality Safety Index A criticality safety index (CSI) of 0 is justified. The CSI is defined in 10 CFR 71.59 [1] as 50/N, where N = infinite for a CSI = 0. Both the NCT and HAC array cases utilize an infinite number of packages.
2.2 Fissile Material Contents The quantities of all fissile isotopes other than 239Pu present in the waste material and other authorized payloads may be converted to an FGE using the conversion factors outlined in the CH-TRAMPAC [2]. For modeling purposes, the package is assumed to contain 239Pu at the FGE limit. The fissile composition of the payload will typically be as follows:
Nuclide Weight Percent 238Pu Trace 239Pu 93.0 240Pu 5.8 241Pu 0.4 242Pu Trace 241Am Trace All other fissile isotopes 0.7
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
10 of 190 No credit is taken for parasitic neutron absorption in waste materials or dunnage. The entire contents of a HalfPACT package are conservatively modeled as an optimally moderated sphere of 239Pu as determined by varying the H/Pu atom ratio. The size of the sphere is calculated based on the H/Pu ratio and the Pu mass.
Two general cases are developed. In Case G, the waste stream is manually compacted (i.e, not machine compacted) and a limit of 325 FGE per HalfPACT is justified. In the Case G models, the moderator is composed of 25% polyethylene and 75% water (by volume), and the internal reflector is composed of 25% polyethylene, 74% water, and 1% beryllium (by volume). In Case H, the waste is machine compacted, and a limit of 245 FGE per HalfPACT is justified. In the Case H models, the moderator is composed of 100% polyethylene, and the internal reflector is composed of 99% polyethylene and 1% beryllium (by volume). The dimension and composition of the fissile sphere as a function of the H/Pu ratio are summarized in Table 2-2 for Case G and Table 2-3 for Case H.
The utilization of polyethylene as the bounding hydrogenous moderating material is justified by the SAIC-1322-001 study [3], which concludes that polyethylene is the most reactive moderator that could credibly moderate TRU waste in a pure form. A 25% volumetric packing fraction for polyethylene is used as a conservative value, which is based on physical testing that bounds the packing fraction of polyethylene in manually compacted TRU waste of 13.36% [4].
Materials that can credibly provide better than 25% polyethylene/75% water equivalent reflection are termed special reflectors and not authorized for shipment in quantities that exceed 1% by weight except in specific configurations discussed below. Based on the results from SAIC-1322-001, Be, BeO, C, D2O, MgO and depleted U 0.3% 235U are the only materials that can provide reflection equivalent to a 2 ft thickness of 25% polyethylene and 75%
water mixture under any of the following conditions and are therefore the only materials considered as special reflectors:
Less than 5/8 inch thick at 100% of theoretical density in the form of large solids.
Less than 11/16 inch thick at 70% of theoretical density in the form of tightly-packed particulate solids.
Less than 20% packing fraction at 24 inches thick in the form of randomly dispersed particulate solids.
Lead and carbon steel, which are present in the wall and lid of the shielded containers, do not meet the definition of a special reflector as defined above in the bulleted list. However, these materials are demonstrated in SAIC-1322-001 to be superior reflectors to a water/poly mix for large thicknesses at theoretical density. Therefore, the shielded containers are modeled explicitly.
The utilization of 1% by volume beryllium in the reflector material filling the inner containment vessel (ICV) bounds the presence of up to 1% by weight quantities of special reflectors that are randomly dispersed in the payload containers based on the volume of the ICV and the maximum allowed weight of the payload containers in the package. SAIC-1322-001 found that beryllium is the bounding special reflector as it provides the best reflection of the system resulting in the highest reactivity.
If the fissile material is bound to the special reflector material, these materials will provide moderation of the fissile material but will not be available to reflect the fissile region. The
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
11 of 190 reference study, SAIC-1322-001, found that adding special reflector materials, with the exception of beryllium, to the fissile region reduced the reactivity of a single 325 FGE 25%
polyethylene/75% water reflected sphere. The moderating effect of heavy water was not studied, but the quantity of liquid allowed in the HalfPACT is limited such that heavy water would not be present in greater than 1% by weight quantities. Thus, for both Case G and Case H, if the special reflector, excluding beryllium, is chemically or mechanically bound to the fissile material, the FGE limits apply even in the presence of greater than 1% by weight quantities of the special reflector. Chemically bound means that the special reflector materials are chemically reacted with the fissile material such that the reflector materials and the fissile materials are chemically interacted and are stable. Mechanically bound means the fissile material is mechanically bound to the reflector such that the reflector material will not disengage from the fissile material because it is topographically imbedded, topographically interlocked, or surface contaminated.
Each special reflector with regard to its possible presence in TRU waste is discussed below.
Beryllium and Beryllium Oxide - Be and BeO may be present in RH-TRU waste in quantities that exceed 1% by weight. However, for transport of shielded containers in the HalfPACT, Be and BeO are specifically limited to quantities not exceeding 1% by weight.
Carbon - Carbon is present as a constituent in RH-TRU waste but not in forms that can reconfigure as a reflector. For example: (1) Carbon may be present as graphite molds or crucibles. In these forms the carbon will be chemically and irreversibly bound to the plutonium or other fissile material and cannot be separated. (2) Carbon may be present in filter media as spent or activated carbon. The plutonium or other fissile material would then be attached to the carbon filter media and would not be easily separated. (3) Carbon may also be present in alloys, which are by definition chemically and/or mechanically bound. In summary, there is no identified mechanism that could cause the carbon in RH-TRU waste to be separated from the fissile material and to be reconfigured as a reflector.
Deuterium - The presence of liquid waste in the payload containers, except for residual amounts in well-drained containers, is prohibited. As specified by the CH-TRAMPAC, the total volume of residual liquid in a payload container shall be less than 1 percent (volume) of the payload container. This limitation on the authorized contents is such that deuterium will not be present in concentrations of greater than 1% by weight.
Magnesium Oxide - Magnesium oxide crucibles used in high-temperature control applications, such as reduction processes, may be present in solid inorganic waste forms such as glass, metal, and pyrochemical salts. If present, magnesium oxide will be bound to the fissile material and would not be easily separated. Magnesium oxide used for neutralization in solidified material cannot be separated out as it is chemically reacted in the waste generation process. There is no identified mechanism that could cause the magnesium oxide in RH-TRU waste to be reconfigured as a reflector.
Depleted Uranium - Depleted uranium may be present in RH-TRU waste, but it will be chemically and/or mechanically bound to the plutonium or physically inseparable because the densities of uranium and plutonium are similar. Separation by mechanical means or by leaching is extremely difficult and is considered highly unlikely in RH-TRU waste after packaging.
Depleted uranium in RH-TRU waste will, therefore, not be separated from the fissile material and reconfigured as a reflector.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
12 of 190 Table 2-2 Case G Fissile Sphere Parameters and Number Densities H/Pu Radius Number Density [a/b-cm]
Ratio
[cm]
Pu-239 H
O C
500 11.1942 1.3934E-04 6.9670E-02 2.4956E-02 9.8791E-03 600 11.8937 1.1617E-04 6.9703E-02 2.4968E-02 9.8837E-03 700 12.5195 9.9608E-05 6.9726E-02 2.4976E-02 9.8870E-03 800 13.0882 8.7179E-05 6.9743E-02 2.4982E-02 9.8895E-03 900 13.6114 7.7508E-05 6.9757E-02 2.4987E-02 9.8914E-03 1000 14.0972 6.9768E-05 6.9768E-02 2.4991E-02 9.8929E-03 1100 14.5517 6.3433E-05 6.9776E-02 2.4994E-02 9.8942E-03 1200 14.9794 5.8153E-05 6.9784E-02 2.4997E-02 9.8952E-03 1300 15.3839 5.3685E-05 6.9790E-02 2.4999E-02 9.8961E-03 1400 15.7683 4.9854E-05 6.9795E-02 2.5001E-02 9.8969E-03 1500 16.1348 4.6533E-05 6.9800E-02 2.5003E-02 9.8975E-03 Table 2-3 Case H Fissile Sphere Parameters and Number Densities H/Pu Radius Number Density [a/b-cm]
Ratio
[cm]
Pu-239 H
C 500 9.7698 1.5801E-04 7.9003E-02 3.9502E-02 600 10.3802 1.3174E-04 7.9045E-02 3.9522E-02 700 10.9261 1.1296E-04 7.9075E-02 3.9537E-02 800 11.4223 9.8871E-05 7.9097E-02 3.9549E-02 900 11.8788 8.7905E-05 7.9114E-02 3.9557E-02 1000 12.3027 7.9128E-05 7.9128E-02 3.9564E-02 1100 12.6992 7.1945E-05 7.9140E-02 3.9570E-02 1200 13.0724 6.5958E-05 7.9149E-02 3.9575E-02 1300 13.4255 6.0890E-05 7.9157E-02 3.9579E-02 1400 13.7608 5.6546E-05 7.9164E-02 3.9582E-02 1500 14.0806 5.2780E-05 7.9170E-02 3.9585E-02 2.3 General Considerations 2.3.1 Model Configuration Criticality calculations for the HalfPACT package are performed using the three-dimensional Monte Carlo computer code KENO-V.a, executed as part of the SCALE version 6.2.3 system [5]
using the CSAS25 driver utility.
The limiting mass of fissile material that may be transported in a single HalfPACT package is shown to provide adequate subcritical margin based on detailed KENO-V.a analyses. These calculations are performed for an optimally moderated single-unit model and an infinite array model of HalfPACT packages under both normal conditions of transport (NCT) and hypothetical accident conditions (HAC).
The basic HalfPACT model is taken directly from the HalfPACT SAR [6]. The only difference is the shielded containers, which have been added to the models to increase reflection of the fissile material.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
13 of 190 The packaging model represents the package structural materials, including the stainless steel shells and polyurethane foam. The model consists of nested, right circular cylindrical shells of Type 304 stainless steel (SS304). The right cylindrical geometry of the model conservatively neglects the torispherical shape of the inner and outer containment vessel ends. The models inner shell represents the combined inner containment vessel (ICV) and outer containment vessel (OCV) components of the actual package. The narrow gap between the ICV and OCV shells is neglected, and the two components are modeled as a single shell of thickness 1/4 + 3/16 = 7/16 inches thick (1.1113 cm) on the side, and 1/4 + 1/4 = 1/2 inches thick (1.270 cm) on the top and bottom. The outside radius of the cylindrical shell representing the combined ICV and OCV components is 38 21/32 inches (98.1869 cm), preserving the outer radius of OCV lid shell. The height of the cylinder, 44 15/16 inches (114.1413 cm), preserves the distance between the upper and lower aluminum honeycomb spacer assemblies within the ICV.
The second, outermost, cylindrical shell is 1/4 inches (0.6350 cm) thick, also of Type 304 stainless steel, and represents the outer containment assembly (OCA) outer shell. The 3/8 inch thick portion of the OCA outer shell is conservatively ignored. Under NCT, the inside radius and inside height of the OCA outer shell are 46 15/16 inches (119.2213 cm) and 70 inches (177.8000 cm), respectively and the outer radius and height are 47 3/16 inches (119.8563 cm) and 70 1/2 inches (179.0700 cm), respectively. Under HAC, the inner radius and height of the OCA outer shell are based on the observed maximum deformation of the OCA following certification testing. At the conclusion of testing, approximately 5 inches of foam remained in the certification test units, except for local areas damaged by puncture bar drops. Hence, the inside of the OCA outer shell is set a distance of 5 inches (12.7000 cm) from the outside of the combined ICV and OCV shell and the 1/4 inches (0.6350 cm) thick OCA shell is modeled.
Under both NCT and HAC, no credit is taken for parasitic neutron absorption properties of the polyurethane foam. Instead, the foam is replaced with the 25% polyethylene/74% water/1%
beryllium mixture as a bounding reflecting material at a volume fraction that maximizes reactivity. Consideration is made for the structural properties of the foam by assuming that the inner cylindrical shell is maintained in its central position subsequent to all HAC tests. The KENO-V.a representation of single-unit undamaged and damaged HalfPACT packages (without the shielded containers) are illustrated in Figure 2-1 and Figure 2-2, respectively. The following simplifying assumptions tend to decrease the amount of structural material represented in the calculational model and decrease the center-to-center separation between HalfPACT packages in the array analyses and are, therefore, conservative.
The domed surfaces of the torispherical heads are represented as flat surfaces and are positioned such that the overall height of the HalfPACT packaging is reduced.
Under HAC, the thickness of the polyurethane foam region is reduced to 5 inches (12.7000 cm) throughout the entire OCA. In all cases, polyurethane foam is ignored and replaced with a polyethylene/water/beryllium mixture that fills the space at a volume fraction that optimizes reactivity.
The shielded containers are modeled in a simplified manner as shown in Table 2-4, based on dimensions obtained from the shielded container assembly drawings [7, 8, 9, 10]. The SC-55G1 container is modeled as a single cylindrical shell of carbon steel. The SC-30G2, SC-30G3, and SC-55G2 containers are modeled as three nested cylinders. The innermost cylinder is modeled as carbon steel and represents the container inner shell, and the steel features on the bottom of the
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
14 of 190 lid and top of the base. The middle shell is modeled as lead and represents the lead shielding present in the container walls, lid and base. The radial extent of the lead in the lid and base is conservatively assumed to extend to the radial extent of the lead in the walls of the container.
This replaces some steel in the corners of the container with a more effective lead reflector in the corners of the container.
In both the SC-30G3 and SC-55G2 containers, the lead shielding ring in the lid of each container is explicitly modeled.
The HalfPACT package may contain a maximum of two SC-30G2 or SC-55G1 containers or a single SC-30G3 or SC-55G2 container.
Figure 2-1 NCT Single Package Model
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
15 of 190 Figure 2-2 HAC Single Package Model Table 2-4 Geometric Model Parameters for the Shielded Containers Container Parameter Unit SC-30G2 SC-30G3 SC-55G1 SC-55G2 Cavity outer diameter
[cm]
51.7652 51.8414 63.5000 63.3984 Cavity height
[cm]
75.5396 75.4888 90.8050 90.7796 Inner steel outer diameter
[cm]
53.2892 54.3814 0.0000 65.9384 Lead outer diameter
[cm]
60.6044 68.5800 0.0000 76.2000 Outer steel outer diameter
[cm]
62.2300 71.1200 74.6760 78.7400 Outer steel bottom thickness
[cm]
2.2352 3.8100 5.9690 3.1750 Outer steel top thickness
[cm]
6.0452 6.9850 6.0960 7.6200 Lead bottom thickness
[cm]
3.0734 6.3754 0.0000 4.4704 Lead top thickness
[cm]
1.9304 5.8166 0.0000 3.8354 Inner steel bottom thickness
[cm]
2.3114 4.4196 0.0000 3.1496 Inner steel top thickness
[cm]
1.9050 4.4450 0.0000 3.1750 Lid lead ring thickness
[cm]
0.0000 1.9050 0.0000 1.2700 Lid lead ring inner diameter
[cm]
0.0000 45.0850 0.0000 54.9402 Lid lead ring outer diameter
[cm]
0.0000 59.6900 0.0000 67.6402 Lid lead ring cover thickness
[cm]
0.0000 0.4547 0.0000 0.4547 Dimensions employed are conservative with respect to dimensions provided in [7, 8, 9, 10]
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
16 of 190 2.3.2 Material Properties The fissile sphere number densities for Case G and Case H are provided in Table 2-2 and Table 2-3, respectively.
The packaging materials are comprised of stainless steel, carbon steel, and lead. The default material properties within SCALE are utilized for these materials [5].
The reflector represents the regions outside the fissile sphere. The composition of the reflector region inside the ICV varies with the case being modeled. For Case G (manually compacted waste), the ICV reflector is comprised of 25% polyethylene, 1% beryllium, and 74% water (by volume). This material is referred to as PolyWaterBe below. For Case H (machine compacted waste), the reflector is comprised of 99% polyethylene and 1% beryllium (by volume) and is referred to as PolyBe below. The density of each base constituent is 0.9982 g/cm3 for water, 0.923 g/cm3 for polyethylene, and 1.85 g/cm3 for beryllium. For some array models, the reflector is replaced by dry air or the density of the reflector regions are varied by applying volume fraction multipliers.
The external reflector is modeled as full density water (0.9982 g/cm3) for the single package models, and as either dry air or water at variable density for the array models.
2.3.3 Computer Codes and Cross-Section Libraries Calculations for the HalfPACT package are performed with the three-dimensional Monte Carlo transport theory code, KENO-V.a v6.3.2. The CSAS5 utility is used as a driver for the KENO code. In this role, CSAS5 automatically prepares the necessary input for the KENO code based on a simplified input description. The ENDF/B-VII.1 continuous energy (ce_v7.1_endf), cross-section library is used as the nuclear data library for the KENO-V.a code.
The KENO code has been used extensively in the criticality safety industry. KENO-V.a is an extension of earlier versions of the KENO code and includes many versatile geometry capabilities and screen plots to facilitate geometry verification. The KENO-V.a code and the ENDF/B-VII.1 evaluated nuclear data library in continuous energy (CE_V7.1_ENDF) form are validated for proper operation on the computer platform by performing criticality analyses of a number of relevant benchmark criticality experiments. A description of these benchmark calculations, along with justification for the computed bias in the code and library for the relevant region of applicability, is provided in Section 4.0.
Models are run with 10,000 neutrons per generation for 1,100 generations, skipping the first 100.
The 1-sigma uncertainty is approximately 0.00030 for all cases.
2.3.4 Demonstration of Maximum Reactivity Calculations are performed for 325 FGE manually compacted waste (Case G), and 245 FGE machine compacted waste (Case H). The single-package analyses exclude configurations where reflector regions are modeled as air, since these configurations have lower reactivity than the fully-reflected configurations.
For Case G, the moderator is modeled as a composition of 25% polyethylene and 75% water (by volume). As polyethylene is a superior moderator than water, this composition results in higher reactivites than would be achieved by water moderation alone. This volume fraction of polyethylene is conservatively higher than the maximum value achievable for manually
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
17 of 190 compacted (i.e., not machine compacted) waste determined by experiment. The reflector is modeled as a mixture of 25% polyethylene, 74% water, and 1% beryllium (by volume). Since the density of beryllium is greater than polyethylene or water, the inclusion of beryllium at 1% by volume necessarily corresponds to a mass fraction conservatively greater than 1%. Beryllium is a more effective reflector than either water or polyethylene, and the inclusion of beryllium is conservative, although at such a small volume fraction, the beryllium has only a small effect on the system reactivity. The presence of beryllium in the moderator at 1% volume fraction is shown to lead to a lower reactivity than the polyethylene/water moderator for the overall worst Case G model as shown in Section 3.2. Hence, beryllium is not represented in the moderator of the modeled fissle sphere.
For Case H, the moderator is modeled as 100% polyethylene. As polyethylene is a superior moderator than water, this composition results in higher reactivites than would be achieved by water moderation alone. The reflector is modeled as a mixture of 99% polyethylene and 1%
beryllium (by volume). Beryllium is a more effective reflector than polyethylene and the inclusion of beryllium is conservative, although at such a small volume fraction, the beryllium has only a small effect on the system reactivity. The presence of beryllium in the moderator at 1% volume fraction is shown to lead to a lower reactivity than the polyethylene-only moderator for the overall worst Case H model as shown in Section 3.2. Hence, beryllium is not represented in the moderator of the modeled fissle sphere.
In all models, the fissile material is assumed to form a single optimally moderated sphere. It is extremely unlikely that fissile material could escape from the shielded containers and reconfigure, or travel from one shielded container to another and reconfigure.
Conservative damage assumptions are utilized in both the NCT and HAC analysis. No credit is taken for the torispherical head of the HalfPACT, which would increase separation distance in the array configuration. All foam and aluminum regions are replaced with reflector at the most reactive density. In the array models, the internal and external reflector densities are varied in order to maximize neutron interaction between packages.
This calculation addresses only <1% by weight special reflectors (beryllium). Special reflectors that are in >1% by weight quantities are not allowed unless chemically or mechanically bound to the fissile material. Lead and steel are not considered special reflectors, although these materials are more reflective than poly/water at large thicknesses. As the shielded containers have thick steel lids and bottoms and lead side walls clad in steel, the presence of the shielded containers slightly increases the reactivity. Various configurations of fissile sphere and shielded container are evaluated. The most reactive configuration (for both single package and array) always occurs when the fissile sphere is in a corner of a shielded container, which maximizes reflection. The results are also higher when the sphere is in the SC-30G3 container, which has the thickest lead of the containers modeled.
The maximum reactivity of the single package and infinite array models are nearly identical for most cases. This indicates that neutron communication between packages is rather limited, and the fissile material is largely isolated. The most reactive HAC single package model (ks = 0.93425) is only slightly less reactive than the most reactive HAC array model (ks = 0.93616), although the arrangements within the package are quite different. Case G results
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
18 of 190 in higher reactivities than Case H, although Case H has a much lower fissile mass. All results are below the USL of 0.9375.
2.4 Payload Configurations Various arrangements and positions of the shielded container payload withing the package are considered as described in Table 2-5 and shown graphically in Section 3.1. Each case is described using a base configuration consisting of a specific arrangement of shielded container(s) and source sphere. A configuration can be translated and rotated (subject to limitations of KENO-V.a geometry) within the package. The source sphere is modeled either inside a shielded container and translated within the shielded container, or outside of the shielded container, in which case it is translated within the HalfPACT inner cavity to an optimally reactive location.
A specific model is determined by specifying a configuration, its location and orientation within the package, the shielded containers present, and the reflector conditions within the shielded containers, ICV, OCA, and outside the package. If the fissile sphere is located inside a container, the sphere position at either the center, side, or top corner of the container cavity is also specified.
Table 2-5 Payload Configurations Configuration Description A0 No shielded containers present, only the fissile sphere within package cavity.
A1 One SC-30G3 or SC-55G2 containers with fissile sphere inside container at center, side, or corner position.
A2 Two SC-30G2 or SC-55G1 containers adjacent to each other with fissile sphere inside one container at center or translated to the interior side or corner nearest the other container.
B2 Two SC-30G2 or SC-55G1 containers with fissile sphere between them located at the container axial midpoint.
C1 One SC-30G3 or SC-55G2 container with fissile sphere outside the top of the container at the corner C2 Two SC-30G2 or SC-55G1 containers adjacent, with fissile sphere outside the pair of containers and in contact with both. Axial sphere position adjacent to container lid.
D1 One SC-30G3 or SC-55G2 container with fissile sphere outside the bottom of the container at the corner E2 Two SC-30G2 or SC-55G1 containers adjacent with fissile sphere inside the second container and positioned such that side and corner sphere locations are closest to ICV wall.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
19 of 190 3.0 RESULTS Several configurations of the shielded containers within the HalfPACT were evaluated as described in Table 2-5. Figures of each are shown below with the maximum ks value for NCT and HAC, single package and array configurations. These results are then summarized in Sections 3.2 for Case G manually-compacted waste and in Section 3.3 for Case H machine-compacted waste.
3.1 Configuration Results The following figures and tables provide the results for both Case G and Case H reflector conditions for NCT and HAC single-package and array models.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
20 of 190 3.1.1 Configuration A0 - No Shielded Container Figure 3-1 Configuration A0 at Center and 45° Corner Locations Table 3-1 Results for Configuration A0 Payload Container None None None Location Center Corner Corner Rotation 0° 0° 45° Sphere Outside Outside Outside Case G - Configuration A0 - No Container Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.92707 0.92205 0.92244 HAC 0.92730 0.92268 0.92297 Case ba_ns325a0c00g0s bb_ns325a0c00g0s bc_ns325a0c00g0s Series ba_hs325a0c00g0s bb_hs325a0c00g0s bc_hs325a0c00g0s Array Condition NCT 0.92757 0.92258 0.92282 HAC 0.92746 0.92258 0.92245 Case ba_na325a0c00g0s bb_na325a0c00g0s bc_na325a0c00g0s Series ba_ha325a0c00g0s bb_ha325a0c00g0s bc_ha325a0c00g0s Case H - Configuration A0 - No Container Reflector SC PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.92301 0.91870 0.91887 HAC 0.92283 0.91877 0.91880 Case ba_ns245a0c00g0s bb_ns245a0c00g0s bc_ns245a0c00g0s Series ba_hs245a0c00g0s bb_hs245a0c00g0s bc_hs245a0c00g0s Array Condition NCT 0.92340 0.91892 0.91867 HAC 0.92320 0.91892 0.91858 Case ba_na245a0c00g0s bb_na245a0c00g0s bc_na245a0c00g0s Series ba_ha245a0c00g0s bb_ha245a0c00g0s bc_ha245a0c00g0s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
21 of 190 3.1.2 Configuration A1 - One SC-30G3 or SC-55G2 Container with Sphere Inside Figure 3-2 Configuration A1 with SC-30G3 Container at Center and Corner Locations - Sphere in Corner Table 3-2 Results for Configuration A1 with Sphere Inside SC-30G3 Container Payload Container SC-30G3 SC-30G3 SC-30G3 SC-30G3 Location Center Center Center Corner Rotation 0° 0° 0° 0° Sphere Corner Center Side Corner Case G - Configuration A1 - SC-30G3 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Air Outside Water Water Water Air Single Condition NCT 0.93385 0.92781 0.93089 HAC 0.93425 0.92780 0.93074 Case da_ns325a1c33g1s da_ns325a1c33g2s da_ns325a1c33g3s Series da_hs325a1c33g1s da_hs325a1c33g2s da_hs325a1c33g3s Array Condition NCT 0.93467 0.92800 0.93109 0.93475 HAC 0.93499 0.92811 0.93033 0.93616 Case da_na325a1c33g1s da_na325a1c33g2s da_na325a1c33g3s dj_na325a1c33g1s Series da_ha325a1c33g1s da_ha325a1c33g2s da_ha325a1c33g3s dj_ha325a1c33g1s Case H - Configuration A1 - SC-30G3 Reflector SC PolyBe PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Air Outside Water Water Water Air Single Condition NCT 0.92958 0.92321 0.92610 HAC 0.92955 0.92309 0.92578 Case da_ns245a1c33g1s da_ns245a1c33g2s da_ns245a1c33g3s Series da_hs245a1c33g1s da_hs245a1c33g2s da_hs245a1c33g3s Array Condition NCT 0.92952 0.92308 0.92592 0.92985 HAC 0.92886 0.92329 0.92568 0.93026 Case da_na245a1c33g1s da_na245a1c33g2s da_na245a1c33g3s dj_na245a1c33g1s Series da_ha245a1c33g1s da_ha245a1c33g2s da_ha245a1c33g3s dj_ha245a1c33g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
22 of 190 Figure 3-3 Configuration A1 with SC-55G2 Container at Center - Sphere in Center and Side Locations Table 3-3 Results for Configuration A1 with Sphere Inside SC-55G2 Container Payload Container SC-55G2 SC-55G2 SC-55G2 SC-55G2 Location Center Center Center Corner Rotation 0° 0° 0° 0° Sphere Corner Center Side Corner Case G - Configuration A1 - SC-55G2 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Air Outside Water Water Water Air Single Condition NCT 0.93257 0.92757 0.92942 HAC 0.93273 0.92746 0.92957 Case fa_ns325a1c52g1s fa_ns325a1c52g2s fa_ns325a1c52g3s Series fa_hs325a1c52g1s fa_hs325a1c52g2s fa_hs325a1c52g3s Array Condition NCT 0.93314 0.92754 0.92978 0.93271 HAC 0.93271 0.92760 0.92988 0.93433 Case fa_na325a1c52g1s fa_na325a1c52g2s fa_na325a1c52g3s fj_na325a1c52g1s Series fa_ha325a1c52g1s fa_ha325a1c52g2s fa_ha325a1c52g3s fj_ha325a1c52g1s Case H - Configuration A1 - SC-55G2 Reflector SC PolyBe PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Air Outside Water Water Water Air Single Condition NCT 0.92818 0.92289 0.92477 HAC 0.92784 0.92278 0.92494 Case fa_ns245a1c52g1s fa_ns245a1c52g2s fa_ns245a1c52g3s Series fa_hs245a1c52g1s fa_hs245a1c52g2s fa_hs245a1c52g3s Array Condition NCT 0.92778 0.92316 0.92510 0.92831 HAC 0.92825 0.92343 0.92510 0.92888 Case fa_na245a1c52g1s fa_na245a1c52g2s fa_na245a1c52g3s fj_na245a1c52g1s Series fa_ha245a1c52g1s fa_ha245a1c52g2s fa_ha245a1c52g3s fj_ha245a1c52g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
23 of 190 3.1.3 Configuration A2 - Two SC-30G2 or SC-55G1 Containers with Sphere Inside Figure 3-4 Configuration A2 with SC-30G2 Container at Center Location - Sphere in Corner and Side Locations Table 3-4 Results for Configuration A2 with Sphere Inside SC-30G2 Container Payload Container SC-30G2 SC-30G2 SC-30G2 Location Center Center Center Rotation 0° 0° 0° Sphere Corner Center Side Case G - Configuration A2 - SC-30G2 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.93172 0.92758 0.92937 HAC 0.93197 0.92744 0.92951 Case ca_ns325a2c32g1s ca_ns325a2c32g2s ca_ns325a2c32g3s Series ca_hs325a2c32g1s ca_hs325a2c32g2s ca_hs325a2c32g3s Array Condition NCT 0.93240 0.92797 0.92914 HAC 0.93184 0.92796 0.92963 Case ca_na325a2c32g1s ca_na325a2c32g2s ca_na325a2c32g3s Series ca_ha325a2c32g1s ca_ha325a2c32g2s ca_ha325a2c32g3s Case H - Configuration A2 - SC-30G2 Reflector SC PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.92704 0.92278 0.92485 HAC 0.92664 0.92276 0.92504 Case ca_ns245a2c32g1s ca_ns245a2c32g2s ca_ns245a2c32g3s Series ca_hs245a2c32g1s ca_hs245a2c32g2s ca_hs245a2c32g3s Array Condition NCT 0.92701 0.92293 0.92460 HAC 0.92711 0.92322 0.92501 Case ca_na245a2c32g1s ca_na245a2c32g2s ca_na245a2c32g3s Series ca_ha245a2c32g1s ca_ha245a2c32g2s ca_ha245a2c32g3s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
24 of 190 Figure 3-5 Configuration A2 with SC-55G1 Container at Center Location - Sphere in Corner and Center Locations Table 3-5 Results for Configuration A2 with Sphere Inside SC-55G1 Container Payload Container SC-55G1 SC-55G1 SC-55G1 Location Center Center Center Rotation 0° 0° 0° Sphere Corner Center Side Case G - Configuration A2 - SC-55G1 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.93115 0.92794 0.92993 HAC 0.93166 0.92726 0.92991 Case ea_ns325a2c51g1s ea_ns325a2c51g2s ea_ns325a2c51g3s Series ea_hs325a2c51g1s ea_hs325a2c51g2s ea_hs325a2c51g3s Array Condition NCT 0.93144 0.92739 0.93023 HAC 0.93143 0.92761 0.93016 Case ea_na325a2c51g1s ea_na325a2c51g2s ea_na325a2c51g3s Series ea_ha325a2c51g1s ea_ha325a2c51g2s ea_ha325a2c51g3s Case H - Configuration A2 - SC-55G1 Reflector SC PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Single Condition NCT 0.92702 0.92327 0.92548 HAC 0.92619 0.92260 0.92575 Case ea_ns245a2c51g1s ea_ns245a2c51g2s ea_ns245a2c51g3s Series ea_hs245a2c51g1s ea_hs245a2c51g2s ea_hs245a2c51g3s Array Condition NCT 0.92677 0.92343 0.92551 HAC 0.92685 0.92327 0.92502 Case ea_na245a2c51g1s ea_na245a2c51g2s ea_na245a2c51g3s Series ea_ha245a2c51g1s ea_ha245a2c51g2s ea_ha245a2c51g3s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
25 of 190 3.1.4 Configuration B2 - Two SC-30G2 or SC-55G1 Containers with Sphere Between the Containers Figure 3-6 Configuration B2 with SC-30G2 and SC-55G1 Containers at Center Location Table 3-6 Results for Configuration B2 with Sphere Between SC-30G2 and SC-55G1 Containers Payload Container SC-30G2 SC-55G1 Location Center Center Rotation 0° 0° Sphere Outside Outside Case G - Configuration B2 - SC-30G2 & SC-55G1 Reflector SC PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92808 0.92864 HAC 0.92837 0.92839 Case cb_ns325b2c32g0s eb_ns325b2c51g0s Series cb_hs325b2c32g0s eb_hs325b2c51g0s Array Condition NCT 0.92813 0.92878 HAC 0.92800 0.92879 Case cb_na325b2c32g0s eb_na325b2c51g0s Series cb_ha325b2c32g0s eb_ha325b2c51g0s Case H - Configuration B2 - SC-30G2 & SC-55G1 Reflector SC PolyBe PolyBe ICV PolyBe PolyBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92321 0.92469 HAC 0.92355 0.92468 Case cb_ns245b2c32g0s eb_ns245b2c51g0s Series cb_hs245b2c32g0s eb_hs245b2c51g0s Array Condition NCT 0.92350 0.92472 HAC 0.92348 0.92457 Case cb_na245b2c32g0s eb_na245b2c51g0s Series cb_ha245b2c32g0s eb_ha245b2c51g0s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
26 of 190 3.1.5 Configuration C1 - One SC-30G3 or SC-55G2 Container with Sphere Outside at Top Corner Figure 3-7 Configuration C1 with SC-30G3 and SC-55G2 Containers at Corner Location - Sphere Outside at Top of Container Table 3-7 Results for Configuration C1 with Sphere Outside of SC-30G3 and SC-55G2 Containers Payload Container SC-30G3 SC-55G2 Location Corner Corner Rotation 0° 0° Sphere Outside Outside Case G - Configuration C1 - SC-30G3 & SC-55G2 Reflector SC PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92535 0.92519 HAC 0.92543 0.92514 Case db_ns325c1c33g0s fb_ns325c1c52g0s Series db_hs325c1c33g0s fb_hs325c1c52g0s Array Condition NCT 0.92515 0.92558 HAC 0.92572 0.92537 Case db_na325c1c33g0s fb_na325c1c52g0s Series db_ha325c1c33g0s fb_ha325c1c52g0s Case H - Configuration C1 - SC-30G3 & SC-55G2 Reflector SC PolyBe PolyBe ICV PolyBe PolyBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92124 0.92108 HAC 0.92118 0.92127 Case db_ns245c1c33g0s fb_ns245c1c52g0s Series db_hs245c1c33g0s fb_hs245c1c52g0s Array Condition NCT 0.92100 0.92113 HAC 0.92107 0.92153 Case db_na245c1c33g0s fb_na245c1c52g0s Series db_ha245c1c33g0s fb_ha245c1c52g0s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
27 of 190 3.1.6 Configuration C2 - Two SC-30G2 or SC-55G1 Containers with Sphere Outside and in Contact with Both Containers Figure 3-8 Configuration C2 with Containers SC-30G2 at 0° and SC-55G1 at 45° at Corner Location - Sphere Outside and in Contact with Both Containers Table 3-8 Results for Configuration C2 with Sphere Outside SC-30G2 and SC-55G1 Containers Payload Container SC-30G2 SC-30G2 SC-55G1 SC-55G1 Location Corner Corner Corner Corner Rotation 0° 45° 0° 45° Sphere Outside Outside Outside Outside Case G - Configuration C2 - SC-30G2 & SC-55G1 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Water Single Condition NCT 0.92363 0.92383 0.92585 0.92546 HAC 0.92390 0.92336 0.92547 0.92614 Case cc_ns325c2c32g0s cd_ns325c2c32g0s ec_ns325c2c51g0s ed_ns325c2c51g0s Series cc_hs325c2c32g0s cd_hs325c2c32g0s ec_hs325c2c51g0s ed_hs325c2c51g0s Array Condition NCT 0.92287 0.92334 0.92596 0.92621 HAC 0.92362 0.92396 0.92619 0.92603 Case cc_na325c2c32g0s cd_na325c2c32g0s ec_na325c2c51g0s ed_na325c2c51g0s Series cc_ha325c2c32g0s cd_ha325c2c32g0s ec_ha325c2c51g0s ed_ha325c2c51g0s Case H - Configuration C2 - SC-30G2 & SC-55G1 Reflector SC PolyBe PolyBe PolyBe PolyBe ICV PolyBe PolyBe PolyBe PolyBe OCA PolyWaterBe PolyWaterBe PolyWaterBe PolyWaterBe Outside Water Water Water Water Single Condition NCT 0.91984 0.92004 0.92295 0.92263 HAC 0.91982 0.92031 0.92262 0.92317 Case cc_ns245c2c32g0s cd_ns245c2c32g0s ec_ns245c2c51g0s ed_ns245c2c51g0s Series cc_hs245c2c32g0s cd_hs245c2c32g0s ec_hs245c2c51g0s ed_hs245c2c51g0s Array Condition NCT 0.91991 0.91997 0.92264 0.92263 HAC 0.91984 0.92015 0.92283 0.92297 Case cc_na245c2c32g0s cd_na245c2c32g0s ec_na245c2c51g0s ed_na245c2c51g0s Series cc_ha245c2c32g0s cd_ha245c2c32g0s ec_ha245c2c51g0s ed_ha245c2c51g0s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
28 of 190 3.1.7 Configuration D1 - One SC-30G3 or SC-55G2 Container with Sphere Outside at Bottom Corner Figure 3-9 Configuration D1 with Containers SC-30G3 and SC-55G2 at Corner Location - Sphere Outside at Bottom of Container Table 3-9 Results for Configuration D1 with Sphere Outside SC-30G3 and SC-55G2 Containers Payload Container SC-30G3 SC-55G2 Location Corner Corner Rotation 0° 0° Sphere Outside Outside Case G - Configuration D1 - SC-30G3 & SC-55G2 Reflector SC PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92525 0.92478 HAC 0.92521 0.92486 Case df_ns325d1c33g0s ff_ns325d1c52g0s Series df_hs325d1c33g0s ff_hs325d1c52g0s Array Condition NCT 0.92525 0.92449 HAC 0.92535 0.92511 Case df_na325d1c33g0s ff_na325d1c52g0s Series df_ha325d1c33g0s ff_ha325d1c52g0s Case H - Configuration D1 - SC-30G3 & SC-55G2 Reflector SC PolyBe PolyBe ICV PolyBe PolyBe OCA PolyWaterBe PolyWaterBe Outside Water Water Single Condition NCT 0.92155 0.92080 HAC 0.92130 0.92036 Case df_ns245d1c33g0s ff_ns245d1c52g0s Series df_hs245d1c33g0s ff_hs245d1c52g0s Array Condition NCT 0.92068 0.92069 HAC 0.92167 0.92133 Case df_na245d1c33g0s ff_na245d1c52g0s Series df_ha245d1c33g0s ff_ha245d1c52g0s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
29 of 190 3.1.8 Configuration E2 - Two SC-30G2 or SC-55G1 Containers with Sphere Inside Outermost Container Figure 3-10 Configuration E2 with SC-30G2 Containers at Corner Location - Fully Reflected and Air Reflected Cases Table 3-10 Results for Configuration E2 with Sphere Inside SC-30G2 Containers Payload Container SC-30G2 SC-30G2 SC-30G2 Location Corner Corner Corner Rotation 0° 45° 0° Sphere Corner Corner Corner Case G - Configuration E2 - SC-30G2 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe Air OCA PolyWaterBe PolyWaterBe Air Outside Water Water Air Single Condition NCT 0.93141 0.93174 HAC 0.93146 0.93104 Case ga_ns325e2c32g1s gb_ns325e2c32g1s Series ga_hs325e2c32g1s gb_hs325e2c32g1s Array Condition NCT 0.93218 0.93148 0.93336 HAC 0.93164 0.93123 0.93521 Case ga_na325e2c32g1s gb_na325e2c32g1s ge_na325e2c32g1s Series ga_ha325e2c32g1s gb_ha325e2c32g1s ge_ha325e2c32g1s Case H - Configuration E2 - SC-30G2 Reflector SC PolyBe PolyBe PolyBe ICV PolyBe PolyBe Air OCA PolyWaterBe PolyWaterBe Air Outside Water Water Air Single Condition NCT 0.92685 0.92680 HAC 0.92643 0.92657 Case ga_ns245e2c32g1s gb_ns245e2c32g1s Series ga_hs245e2c32g1s gb_hs245e2c32g1s Array Condition NCT 0.92687 0.92663 0.92780 HAC 0.92706 0.92702 0.92994 Case ga_na245e2c32g1s gb_na245e2c32g1s ge_na245e2c32g1s Series ga_ha245e2c32g1s gb_ha245e2c32g1s ge_ha245e2c32g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
30 of 190 Figure 3-11 Configuration E2 with SC-30G2 Containers at 45° at Corner Location - Air Reflected and SC/ICV Reflected Cases Table 3-10 Results for Configuration E2 with Sphere Inside SC-30G2 Containers - Continued Payload Container SC-30G2 SC-30G2 SC-30G2 Location Corner Corner Corner Rotation 45° 0° 45° Sphere Corner Corner Corner Case G - Configuration E2 - SC-30G2 continued Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV Air PolyWaterBe PolyWaterBe OCA Air Air Air Outside Air Air Air Single Condition NCT HAC Case Series Array Condition NCT 0.93283 0.93185 0.93168 HAC 0.93381 0.93354 0.93267 Case gf_na325e2c32g1s gi_na325e2c32g1s gj_na325e2c32g1s Series gf_ha325e2c32g1s gi_ha325e2c32g1s gj_ha325e2c32g1s Case H - Configuration E2 - SC-30G2 continued Reflector SC PolyBe PolyBe PolyBe ICV Air PolyBe PolyBe OCA Air Air Air Outside Air Air Air Single Condition NCT HAC Case Series Array Condition NCT 0.92748 0.92702 0.92607 HAC 0.92831 0.92880 0.92727 Case gf_na245e2c32g1s gi_na245e2c32g1s gj_na245e2c32g1s Series gf_ha245e2c32g1s gi_ha245e2c32g1s gj_ha245e2c32g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
31 of 190 Figure 3-12 Configuration E2 with SC-55G1 Containers at Corner Location - Fully Reflected and Air Reflected Cases Table 3-11 Results for Configuration E2 with Sphere Inside SC-55G1 Containers Payload Container SC-55G1 SC-55G1 SC-55G1 Location Corner Corner Corner Rotation 0° 45° 0° Sphere Corner Corner Corner Case G - Configuration E2 - SC-55G1 Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV PolyWaterBe PolyWaterBe Air OCA PolyWaterBe PolyWaterBe Air Outside Water Water Air Single Condition NCT 0.93154 0.93168 HAC 0.93161 0.93140 Case ha_ns325e2c51g1s hb_ns325e2c51g1s Series ha_hs325e2c51g1s hb_hs325e2c51g1s Array Condition NCT 0.93171 0.93135 0.93304 HAC 0.93156 0.93110 0.93540 Case ha_na325e2c51g1s hb_na325e2c51g1s he_na325e2c51g1s Series ha_ha325e2c51g1s hb_ha325e2c51g1s he_ha325e2c51g1s Case H - Configuration E2 - SC-55G1 Reflector SC PolyBe PolyBe PolyBe ICV PolyBe PolyBe Air OCA PolyWaterBe PolyWaterBe Air Outside Water Water Air Single Condition NCT 0.92680 0.92696 HAC 0.92687 0.92703 Case ha_ns245e2c51g1s hb_ns245e2c51g1s Series ha_hs245e2c51g1s hb_hs245e2c51g1s Array Condition NCT 0.92710 0.92681 0.92816 HAC 0.92729 0.92652 0.93039 Case ha_na245e2c51g1s hb_na245e2c51g1s he_na245e2c51g1s Series ha_ha245e2c51g1s hb_ha245e2c51g1s he_ha245e2c51g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
32 of 190 Figure 3-13 Configuration E2 with SC-55G1 Containers at 45° at Corner Location - Air Reflected and SC/ICV Reflected Cases Table 3-11 Results for Configuration E2 with Sphere Inside SC-55G1 Containers - Continued Payload Container SC-55G1 SC-55G1 SC-55G1 Location Corner Corner Corner Rotation 45° 0° 45° Sphere Corner Corner Corner Case G - Configuration E2 - SC-55G1 continued Reflector SC PolyWaterBe PolyWaterBe PolyWaterBe ICV Air PolyWaterBe PolyWaterBe OCA Air Air Air Outside Air Air Air Single Condition NCT HAC Case Series Array Condition NCT 0.93262 0.93200 0.93171 HAC 0.93354 0.93447 0.93295 Case hf_na325e2c51g1s hi_na325e2c51g1s hj_na325e2c51g1s Series hf_ha325e2c51g1s hi_ha325e2c51g1s hj_ha325e2c51g1s Case H - Configuration E2 - SC-55G1 continued Reflector SC PolyBe PolyBe PolyBe ICV Air PolyBe PolyBe OCA Air Air Air Outside Air Air Air Single Condition NCT HAC Case Series Array Condition NCT 0.92743 0.92717 0.92680 HAC 0.92915 0.92935 0.92822 Case hf_na245e2c51g1s hi_na245e2c51g1s hj_na245e2c51g1s Series hf_ha245e2c51g1s hi_ha245e2c51g1s hj_ha245e2c51g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
33 of 190 3.2 Case G - 325 FGE - Manual Compaction The most limiting Case G result is for the HAC array model with an SC-30G3 container in configuration A1 reflected by full density PolyWaterBe in the shielded container and payload cavity and air in the OCA and outside the package. A full set of results for various combinations of H/Pu and reflector volume fraction for this case are shown in Table 3-12.
A summary of the maximum calculated ks values for the 325 g 239Pu mass loading with manually-compacted waste with <1% Be by mass is shown in Table 3-13 for each shielded container under NCT and HAC conditions and single-package and array models.
The single-package maximum reactivities generally occur for fully reflected configurations with the payload centered in the package or in the E2 configuration for the NCT condition with the SC-30G2 and SC-55G1 shielded containers. There is very little difference in reactivity between the various configurations. The maximum single-package ks value is 0.93425 which occurs with the SC-30G3 shielded container in configuration A1 under HAC model conditions.
For the array models, the overall maximum calculated ks value occurs for the HAC array case with the SC-30G3 shielded container in configuration A1 translated to the ICV wall. In this case, the shielded container and payload cavity are filled with PolyWaterBe at full volume fraction and the OCA and outside reflectors are set to air. The maximum ks value is 0.93616.
In all cases analyzed, the optimal reactivity is achieved at an H/Pu ratio within the fissile sphere of 900. Also, calculations in which the reflector volume fractions are varied between 0.01 and 1.0 show that optimal reactivity is achieved at full volume fraction of reflecting material.
The presence of 1% beryllium in the moderator is shown in Table 3-14 to have a lower reactivity for the overall limiting case. Hence, the presence of beryllium in the moderator is not significant.
Table 3-12 Results for Most Limiting Case at Various H/Pu Ratios and Reflector Volume Fractions Case G HAC Array Limiting Case - Config A1 SC-30G3 Corner Sphere - keff H/Pu Reflector Volume Fraction Ratio 0.01 0.05 0.1 0.3 0.5 0.7 0.9 0.95 1
500 0.78387 0.77881 0.79043 0.83338 0.86283 0.88348 0.89911 0.90217 0.90517 600 0.81420 0.80858 0.81781 0.85680 0.88336 0.90140 0.91536 0.91873 0.92105 700 0.83416 0.82862 0.83781 0.87263 0.89665 0.91356 0.92545 0.92808 0.93029 800 0.84824 0.84277 0.85037 0.88274 0.90458 0.91930 0.93023 0.93235 0.93486 900 0.85852 0.85081 0.85882 0.88889 0.90845 0.92151 0.93145 0.93349 0.93616 1000 0.86351 0.85676 0.86358 0.89077 0.90943 0.92163 0.93020 0.93218 0.93384 1100 0.86621 0.85963 0.86525 0.89121 0.90758 0.91859 0.92676 0.92862 0.93078 1200 0.86665 0.85946 0.86557 0.88943 0.90488 0.91511 0.92219 0.92392 0.92526 1300 0.86566 0.85807 0.86410 0.88595 0.89975 0.90958 0.91634 0.91760 0.91935 1400 0.86273 0.85562 0.86058 0.88145 0.89458 0.90359 0.90974 0.91120 0.91184 1500 0.85914 0.85209 0.85724 0.87586 0.88831 0.89628 0.90245 0.90360 0.90509 Cases from calculation series ib_ha325a1c33g1s
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
34 of 190 Table 3-13 Case G Summary of Maximum Reactivity Results for each Shielded Container Payload Reflector Case Condition Model Container Config (Rotation)
SC ICV OCA Outside NCT Single None A0 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.92707 ba_ns325a0c00g0s0900hx SC-30G2 E2 Corner(45°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93174 gb_ns325e2c32g1s0900hx SC-30G3 A1 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93385 da_ns325a1c33g1s0900hx SC-55G1 E2 Corner(45°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93168 hb_ns325e2c51g1s0900hx SC-55G2 A1 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93257 fa_ns325a1c52g1s0900hx Array None A0 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.92757 ba_na325a0c00g0s0900hx SC-30G2 E2 Corner(0°)
PolyWaterBe Air Air Air 0.93336 ge_na325e2c32g1s0900hx SC-30G3 A1 Corner(0°)
PolyWaterBe PolyWaterBe Air Air 0.93475 dj_na325a1c33g1s0900hx SC-55G1 E2 Corner(0°)
PolyWaterBe Air Air Air 0.93304 he_na325e2c51g1s0900hx SC-55G2 A1 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93314 fa_na325a1c52g1s0900hx HAC Single None A0 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.92730 ba_hs325a0c00g0s0900hx SC-30G2 A2 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93197 ca_hs325a2c32g1s0900hx SC-30G3 A1 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93425 da_hs325a1c33g1s0900hx SC-55G1 A2 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93166 ea_hs325a2c51g1s0900hx SC-55G2 A1 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.93273 fa_hs325a1c52g1s0900hx Array None A0 Center(0°)
PolyWaterBe PolyWaterBe PolyWaterBe Water 0.92746 ba_ha325a0c00g0s0900hx SC-30G2 E2 Corner(0°)
PolyWaterBe Air Air Air 0.93521 ge_ha325e2c32g1s0900hx SC-30G3 A1 Corner(0°)
PolyWaterBe PolyWaterBe Air Air 0.93616 dj_ha325a1c33g1s0900hx SC-55G1 E2 Corner(0°)
PolyWaterBe Air Air Air 0.93540 he_ha325e2c51g1s0900hx SC-55G2 A1 Corner(0°)
PolyWaterBe PolyWaterBe Air Air 0.93433 fj_ha325a1c52g1s0900hx Table 3-14 Most Limiting Case G Model with and without 1% (by vol) Beryllium in Moderator Moderator keff Case PolyWater 0.93560 0.00028 0.93616 dj_ha325a1c33g1s0900hx PolyWaterBe 0.93509 0.00027 0.93563 ja_ha325a1c33g1s0900hx
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
35 of 190 3.3 Case H - 245 FGE - Machine Compaction A summary of the maximum calculated ks values for the 245 g 239Pu mass loading with machine-compacted waste with <1% Be by mass is shown in Table 3-15 for each shielded container under NCT and HAC conditions and single-package and array models.
The maximum ks value for all cases is 0.93039 which occurs for the HAC array model of the SC-55G1 container in the E2 configuration with PolyBe reflection provided inside the container but air in the payload cavity, OCA, and outside the package.
The presence of 1% beryllium in the moderator is shown in Table 3-16 to have a lower reactivity for the overall limiting case. Hence, the presence of beryllium in the moderator is not significant.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
36 of 190 Table 3-15 Case H Summary of Maximum Reactivity Results for each Shielded Container Payload Reflector Case Condition Model Container Config (Rotation)
SC ICV OCA Outside NCT Single None A0 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92301 ba_ns245a0c00g0s0900hx SC-30G2 A2 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92704 ca_ns245a2c32g1s0900hx SC-30G3 A1 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92958 da_ns245a1c33g1s0900hx SC-55G1 A2 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92702 ea_ns245a2c51g1s0900hx SC-55G2 A1 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92818 fa_ns245a1c52g1s0900hx Array None A0 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92340 ba_na245a0c00g0s0900hx SC-30G2 E2 Corner(0°)
PolyBe Air Air Air 0.92780 ge_na245e2c32g1s0900hx SC-30G3 A1 Corner(0°)
PolyBe PolyBe Air Air 0.92985 dj_na245a1c33g1s0900hx SC-55G1 E2 Corner(0°)
PolyBe Air Air Air 0.92816 he_na245e2c51g1s0900hx SC-55G2 A1 Corner(0°)
PolyBe PolyBe Air Air 0.92831 fj_na245a1c52g1s0900hx HAC Single None A0 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92283 ba_hs245a0c00g0s1000hx SC-30G2 A2 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92664 ca_hs245a2c32g1s0900hx SC-30G3 A1 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92955 da_hs245a1c33g1s0900hx SC-55G1 E2 Corner(45°)
PolyBe PolyBe PolyWaterBe Water 0.92703 hb_hs245e2c51g1s0900hx SC-55G2 A1 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92784 fa_hs245a1c52g1s0900hx Array None A0 Center(0°)
PolyBe PolyBe PolyWaterBe Water 0.92320 ba_ha245a0c00g0s0900hx SC-30G2 E2 Corner(0°)
PolyBe Air Air Air 0.92994 ge_ha245e2c32g1s0900hx SC-30G3 A1 Corner(0°)
PolyBe PolyBe Air Air 0.93026 dj_ha245a1c33g1s0900hx SC-55G1 E2 Corner(0°)
PolyBe Air Air Air 0.93039 he_ha245e2c51g1s0900hx SC-55G2 A1 Corner(0°)
PolyBe PolyBe Air Air 0.92888 fj_ha245a1c52g1s0900hx Table 3-16 Most Limiting Case H Model with and without 1% (by vol) Beryllium in Moderator Moderator keff Case Poly 0.92985 0.00027 0.93039 he_ha245e2c51g1s0900hx PolyBe 0.92958 0.00030 0.93018 jb_ha245e2c51g1s0900hx
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
37 of 190 4.0 BENCHMARK EVALUATIONS 4.1 Applicability of Benchmark Experiments A total of 196 benchmark experiments of water-reflected solutions of plutonium nitrate are evaluated using the KENO-V.a Monte Carlo criticality code with the SCALE version 6.2.3, continuous energy-group, ENDF-B/V cross-section library.
Detailed descriptions of the benchmark experiments are obtained from the OECD Nuclear Energy Agencys International Handbook of Evaluated Criticality Safety Benchmark Experiments [11]. The critical experiments selected for this analysis are presented in Table 4-1.
Since experiments with Pu fissile material and either beryllium or lead reflector materials are unavailable, a separate analysis is performed to demonstrate that no additional AoA margin is required for these reflector materials.
All criticality models of the HalfPACT package fall within the range of applicability of the benchmark experiments based on the H/Pu ratio and EALF range as follows:
Range of Applicability for HalfPACT Criticality Analysis Range of Applicability for Trending Parameters 59
,803
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
38 of 190 Table 4-1 Benchmark Experiments Utilized Series Title PU-SOL-THERM-001 Water-Reflected 11.5-Inch Diameter Spheres Of Plutonium Nitrate Solutions PU-SOL-THERM-002 Water-Reflected 12-Inch Diameter Spheres Of Plutonium Nitrate Solutions PU-SOL-THERM-003 Water-Reflected 13-Inch Diameter Spheres Of Plutonium Nitrate Solutions PU-SOL-THERM-004 Water-Reflected 14-Inch Diameter Spheres Of Plutonium Nitrate Solutions 0.54% To 3.43% Pu240 PU-SOL-THERM-005 Water-Reflected 14-Inch Diameter Spheres Of Plutonium Nitrate Solutions 4.05% And 4.40% Pu240 PU-SOL-THERM-006 Water-Reflected 15-Inch Diameter Spheres Of Plutonium Nitrate Solutions PU-SOL-THERM-007 Water-Reflected 11.5-Inch Diameter Spheres Partly Filled with Plutonium Nitrate Solutions PU-SOL-THERM-009 Unreflected 48-Inch-Diameter Sphere Of Plutonium Nitrate Solution PU-SOL-THERM-010 Water-Reflected 9-, 10-, 11-, And 12-Inch-Diameter Cylinders Of Plutonium Nitrate Solutions PU-SOL-THERM-011 Bare 16-And 18-Inch-Diameter Spheres Of Plutonium Nitrate Solutions PU-SOL-THERM-014 Interacting Cylinders of 300-mm Diameter Spheres of Plutonium Nitrate Solution (115.1gPu/L) in Air PU-SOL-THERM-015 Interacting Cylinders of 300-mm Diameter with Plutonium Nitrate Solution (152.5gPu/L) in Air PU-SOL-THERM-016 Interacting Cylinders of 300-mm and 256-mm Diameters with Plutonium Nitrate Solution (152.5 and 115.1 gPu/L) and Nitric Acid (2n) in Air PU-SOL-THERM-017 Interacting Cylinders of 256-mm and 300-mm Diameters with Plutonium Nitrate Solution (115.1 gPu/L) in Air PU-SOL-THERM-020 Water-Reflected and Water-Cadmium Reflected 14-inch Diameter Spheres of Plutonium Nitrate Solutions PU-SOL-THERM-021 Water-Reflected and Bare 15.2-inch Diameter Spheres of Plutonium Nitrate Solutions PU-SOL-THERM-024 Slabs of Plutonium Nitrate Solutions Reflected by 1-inch Thick Plexiglas U233-SOL-THERM-015 Uranyl-Fluoride (233U) Solutions in Spherical Stainless Steel Vessels with Reflectors of Be, CH2, and Be-CH2 Composites LEU-COMP-THERM-009 Water-Moderated Rectangular Clusters Of U(4.31)O2 Fuel Rods (2.54-cm Pitch)
Separated by Steel, Boral, Copper, Cadmium, Aluminum, or Zircaloy-4 Plates LEU-COMP-THERM-010 Water-Moderated U(4.31)O2 Fuel Rods Reflected by Two Lead, Uranium, or Steel Walls
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
39 of 190 4.2 Bias Determination Table 4-3 shows the experimental benchmark keff (kexp)and calculated keff values (kcalc) for each Pu solution benchmark experiment. A histogram of the normalized values knorm=kcalc/kexp is shown in Figure 4-1. Three standard tests for normality are applied to the normalized data as summarized in Table 4-2. Since the data fail two of the three normality tests, the distribution is deemed non-normal and the non-parametric method from NUREG/CR-6698 [12] is used to determine the bias and bias uncertainty.
This non-parametric method results in a determination of the degree of confidence that a fraction of the true population of data lies above the smallest observed value. This determination is calculated as follows:
= 1
! (
)! (1
)
where
=level of confidence,
=the desired population fraction (0.95 for this validation),
= the number of data in one data sample,
=the rank order indexing from the smallest sample to the largest (
= 1 for the smallest sample). Non-parametric techniques do not require reliance upon distributions, but are rather an analysis of ranks,
= the ranked sample in the sample population being evaluated.
As stated in NUREG/CR-6698, for a desired population fraction of 95% and a rank order of 1 (the smallest data sample) the equation simplifies to:
= 1 0.95 For a non-parametric set of data, the bias and bias uncertainty are determined as follows:
Bias+Bias Uncertainty = 1 - (Smallest keff value in the data set -
- NPM) where
= standard deviation corresponding to the smallest knorm value in the data set NPM
= non-parametric margin, determined from MoS
= margin of subcriticality (0.02)
With n=196, the level of confidence,, is essentially unity and the corresponding NPM from NUREG/CR-6998 Table 2.2 is zero.
Hence, the resulting bias and bias uncertainty are determined as Bias+Bias Uncertainty = 1 - (0.99277 - 0.00521 - 0.0) = 0.01244
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
40 of 190 Table 4-2 Normality Test Results Test Result Modified Chi-Square Test Not Normal Kolmogorov-Smirnov Test Normal Lilliefors Test Not Normal Figure 4-1 Normalized keff Values for the Pu Benchmark Set 0
10 20 30 40 50 60 70 80 90 100 0.99576 0.99875 1.00174 1.00473 1.00772 1.01071 1.01370 1.01669 1.01968 Bin Average knorm Observed Expected
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
41 of 190 Table 4-3 Benchmark Experiments Results Experiment Calculation Normalized Case k_exp H/Pu k_calc EALF
[eV]
k_norm pust001_case_1 1.00000 0.00500 371 1.00550 0.00031 8.72E-02 1.00550 0.00501 pust001_case_2 1.00000 0.00500 272 1.00753 0.00030 1.10E-01 1.00753 0.00501 pust001_case_3 1.00000 0.00500 216 1.01031 0.00029 1.33E-01 1.01031 0.00501 pust001_case_4 1.00000 0.00500 190 1.00477 0.00030 1.49E-01 1.00477 0.00501 pust001_case_5 1.00000 0.00500 180 1.00878 0.00031 1.57E-01 1.00878 0.00501 pust001_case_6 1.00000 0.00500 91 1.01021 0.00030 3.41E-01 1.01021 0.00501 pust002_case_1 1.00000 0.00470 524 1.00388 0.00027 7.10E-02 1.00388 0.00471 pust002_case_2 1.00000 0.00470 505 1.00455 0.00027 7.26E-02 1.00455 0.00471 pust002_case_3 1.00000 0.00470 451 1.00275 0.00028 7.75E-02 1.00275 0.00471 pust002_case_4 1.00000 0.00470 421 1.00591 0.00027 8.09E-02 1.00591 0.00471 pust002_case_5 1.00000 0.00470 393 1.00921 0.00029 8.45E-02 1.00921 0.00471 pust002_case_6 1.00000 0.00470 344 1.00466 0.00032 9.22E-02 1.00466 0.00471 pust002_case_7 1.00000 0.00470 309 1.00734 0.00029 9.94E-02 1.00734 0.00471 pust003_case_1 1.00000 0.00470 788 1.00224 0.00030 5.84E-02 1.00224 0.00471 pust003_case_2 1.00000 0.00470 756 1.00175 0.00027 5.95E-02 1.00175 0.00471 pust003_case_3 1.00000 0.00470 699 1.00444 0.00030 6.19E-02 1.00444 0.00471 pust003_case_4 1.00000 0.00470 682 1.00388 0.00026 6.27E-02 1.00388 0.00471 pust003_case_5 1.00000 0.00470 627 1.00523 0.00026 6.53E-02 1.00523 0.00471 pust003_case_6 1.00000 0.00470 563 1.00532 0.00030 6.91E-02 1.00532 0.00471 pust003_case_7 1.00000 0.00470 738 1.00628 0.00027 5.92E-02 1.00628 0.00471 pust003_case_8 1.00000 0.00470 714 1.00521 0.00029 6.02E-02 1.00521 0.00471 pust004_case_1 1.00000 0.00470 987 1.00312 0.00026 5.35E-02 1.00312 0.00471 pust004_case_10 1.00000 0.00470 689 1.00138 0.00028 6.31E-02 1.00138 0.00471 pust004_case_11 1.00000 0.00470 592 1.00053 0.00027 6.83E-02 1.00053 0.00471 pust004_case_12 1.00000 0.00470 893 1.00267 0.00031 5.59E-02 1.00267 0.00471 pust004_case_13 1.00000 0.00470 903 1.00007 0.00027 5.57E-02 1.00007 0.00471 pust004_case_2 1.00000 0.00470 977 0.99819 0.00028 5.38E-02 0.99819 0.00471 pust004_case_3 1.00000 0.00470 935 1.00034 0.00028 5.48E-02 1.00034 0.00471 pust004_case_4 1.00000 0.00470 889 0.99809 0.00025 5.61E-02 0.99809 0.00471 pust004_case_5 1.00000 0.00470 942 0.99957 0.00027 5.46E-02 0.99957 0.00471 pust004_case_6 1.00000 0.00470 927 1.00139 0.00026 5.51E-02 1.00139 0.00471 pust004_case_7 1.00000 0.00470 892 1.00522 0.00032 5.59E-02 1.00522 0.00471 pust004_case_8 1.00000 0.00470 869 1.00060 0.00029 5.67E-02 1.00060 0.00471 pust004_case_9 1.00000 0.00470 805 1.00013 0.00028 5.86E-02 1.00013 0.00471 pust005_case_1 1.00000 0.00470 903 1.00152 0.00027 5.57E-02 1.00152 0.00471 pust005_case_2 1.00000 0.00470 868 1.00215 0.00027 5.67E-02 1.00215 0.00471 pust005_case_3 1.00000 0.00470 834 1.00373 0.00026 5.77E-02 1.00373 0.00471 pust005_case_4 1.00000 0.00470 765 1.00437 0.00027 6.01E-02 1.00437 0.00471 pust005_case_5 1.00000 0.00470 694 1.00595 0.00028 6.29E-02 1.00595 0.00471 pust005_case_6 1.00000 0.00470 633 1.00538 0.00027 6.59E-02 1.00538 0.00471 pust005_case_7 1.00000 0.00470 581 1.00361 0.00026 6.90E-02 1.00361 0.00471 pust005_case_8 1.00000 0.00470 869 0.99896 0.00028 5.67E-02 0.99896 0.00471 pust005_case_9 1.00000 0.00470 825 1.00175 0.00025 5.80E-02 1.00175 0.00471 pust006_case_1 1.00000 0.00350 1061 1.00025 0.00030 5.26E-02 1.00025 0.00351 pust006_case_2 1.00000 0.00350 1018 1.00119 0.00027 5.35E-02 1.00119 0.00351 pust006_case_3 1.00000 0.00350 940 1.00109 0.00029 5.53E-02 1.00109 0.00351
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
42 of 190 Experiment Calculation Normalized Case k_exp H/Pu k_calc EALF
[eV]
k_norm pust007_case_10 1.00000 0.00470 285 1.00035 0.00032 1.05E-01 1.00035 0.00471 pust007_case_2 1.00000 0.00470 110 1.00927 0.00030 2.70E-01 1.00927 0.00471 pust007_case_3 1.00000 0.00470 114 1.00355 0.00033 2.56E-01 1.00355 0.00471 pust007_case_5 1.00000 0.00470 268 1.00882 0.00031 1.11E-01 1.00882 0.00471 pust007_case_6 1.00000 0.00470 262 1.00322 0.00031 1.13E-01 1.00322 0.00471 pust007_case_7 1.00000 0.00470 266 1.00549 0.00029 1.11E-01 1.00549 0.00471 pust007_case_8 1.00000 0.00470 258 0.99905 0.00028 1.14E-01 0.99905 0.00471 pust007_case_9 1.00000 0.00470 260 0.99659 0.00028 1.13E-01 0.99659 0.00471 pust009_case_1 1.00000 0.00330 2648 1.01470 0.00026 4.12E-02 1.01470 0.00331 pust009_case_2 1.00000 0.00330 2779 1.01968 0.00022 4.07E-02 1.01968 0.00331 pust009_case_3 1.00000 0.00330 2803 1.01827 0.00023 4.06E-02 1.01827 0.00331 pust010_case_1.11 1.00000 0.00480 485 1.01221 0.00030 7.51E-02 1.01221 0.00481 pust010_case_1.12 1.00000 0.00480 543 1.00904 0.00029 6.97E-02 1.00904 0.00481 pust010_case_1.9 1.00000 0.00480 267 1.01792 0.00028 1.09E-01 1.01792 0.00481 pust010_case_2.11 1.00000 0.00480 558 1.01006 0.00030 6.97E-02 1.01006 0.00481 pust010_case_2.12 1.00000 0.00480 618 1.00895 0.00028 6.54E-02 1.00895 0.00481 pust010_case_2.9 1.00000 0.00480 357 1.01410 0.00033 8.88E-02 1.01410 0.00481 pust010_case_3.11 1.00000 0.00480 558 1.00927 0.00029 6.87E-02 1.00927 0.00481 pust010_case_3.12 1.00000 0.00480 728 1.01560 0.00034 6.08E-02 1.01560 0.00481 pust010_case_3.9 1.00000 0.00480 484 1.00776 0.00033 7.38E-02 1.00776 0.00481 pust010_case_4.11 1.00000 0.00480 606 1.00205 0.00028 6.64E-02 1.00205 0.00481 pust010_case_4.12 1.00000 0.00480 850 1.00993 0.00026 5.71E-02 1.00993 0.00481 pust010_case_5.11 1.00000 0.00480 665 1.00334 0.00028 6.40E-02 1.00334 0.00481 pust010_case_6.11 1.00000 0.00480 414 1.01437 0.00026 8.10E-02 1.01437 0.00481 pust010_case_7.11 1.00000 0.00480 535 1.00227 0.00029 7.03E-02 1.00227 0.00481 pust011_case_1.16 1.00000 0.00520 765 1.00917 0.00030 6.34E-02 1.00917 0.00521 pust011_case_1.18 1.00000 0.00520 1208 0.99387 0.00027 5.22E-02 0.99387 0.00521 pust011_case_2.16 1.00000 0.00520 736 1.01353 0.00033 6.47E-02 1.01353 0.00521 pust011_case_2.18 1.00000 0.00520 1151 0.99943 0.00030 5.32E-02 0.99943 0.00521 pust011_case_3.16 1.00000 0.00520 691 1.01619 0.00033 6.69E-02 1.01619 0.00521 pust011_case_3.18 1.00000 0.00520 1158 0.99582 0.00028 5.31E-02 0.99582 0.00521 pust011_case_4.16 1.00000 0.00520 682 1.00835 0.00029 6.76E-02 1.00835 0.00521 pust011_case_4.18 1.00000 0.00520 1100 0.99277 0.00027 5.44E-02 0.99277 0.00521 pust011_case_5.16 1.00000 0.00520 575 1.00557 0.00028 7.52E-02 1.00557 0.00521 pust011_case_5.18 1.00000 0.00520 1039 1.00301 0.00029 5.58E-02 1.00301 0.00521 pust011_case_6.18 1.00000 0.00520 908 0.99942 0.00026 5.94E-02 0.99942 0.00521 pust011_case_7.18 1.00000 0.00520 1103 0.99883 0.00029 5.41E-02 0.99883 0.00521 pust014_case_1 0.99800 0.00320 220 1.00489 0.00029 1.65E-01 1.00690 0.00321 pust014_case_10 0.99800 0.00320 220 1.00370 0.00031 1.64E-01 1.00571 0.00321 pust014_case_11 0.99800 0.00320 220 1.00336 0.00030 1.64E-01 1.00537 0.00321 pust014_case_12 0.99800 0.00320 220 1.00401 0.00032 1.64E-01 1.00602 0.00322 pust014_case_13 0.99800 0.00430 220 1.00524 0.00033 1.66E-01 1.00725 0.00431 pust014_case_14 0.99800 0.00430 220 1.00343 0.00034 1.65E-01 1.00544 0.00431 pust014_case_15 0.99800 0.00430 220 1.00363 0.00031 1.65E-01 1.00564 0.00431 pust014_case_16 0.99800 0.00430 220 1.00371 0.00030 1.64E-01 1.00572 0.00431 pust014_case_17 0.99800 0.00430 220 1.00294 0.00031 1.64E-01 1.00495 0.00431 pust014_case_18 0.99800 0.00430 220 1.00634 0.00030 1.66E-01 1.00836 0.00431
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
43 of 190 Experiment Calculation Normalized Case k_exp H/Pu k_calc EALF
[eV]
k_norm pust014_case_19 0.99800 0.00430 220 1.00377 0.00034 1.65E-01 1.00578 0.00431 pust014_case_20 0.99800 0.00430 220 1.00390 0.00029 1.65E-01 1.00591 0.00431 pust014_case_21 0.99800 0.00430 220 1.00432 0.00032 1.64E-01 1.00633 0.00431 pust014_case_22 0.99800 0.00430 220 1.00394 0.00029 1.64E-01 1.00595 0.00431 pust014_case_23 0.99800 0.00430 220 1.00294 0.00032 1.64E-01 1.00495 0.00431 pust014_case_24 0.99800 0.00430 220 1.00650 0.00032 1.66E-01 1.00852 0.00431 pust014_case_25 0.99800 0.00430 220 1.00241 0.00032 1.66E-01 1.00442 0.00431 pust014_case_26 0.99800 0.00430 220 1.00313 0.00033 1.65E-01 1.00514 0.00431 pust014_case_27 0.99800 0.00430 220 1.00290 0.00029 1.64E-01 1.00491 0.00431 pust014_case_28 0.99800 0.00430 220 1.00329 0.00031 1.64E-01 1.00530 0.00431 pust014_case_29 0.99800 0.00430 220 1.00202 0.00032 1.64E-01 1.00403 0.00431 pust014_case_3 0.99800 0.00320 220 1.00346 0.00035 1.65E-01 1.00547 0.00322 pust014_case_30 0.99800 0.00430 220 1.00395 0.00029 1.66E-01 1.00596 0.00431 pust014_case_31 0.99800 0.00430 220 1.00209 0.00035 1.66E-01 1.00410 0.00431 pust014_case_33 0.99800 0.00430 220 1.00322 0.00030 1.65E-01 1.00523 0.00431 pust014_case_34 0.99800 0.00430 220 1.00315 0.00030 1.65E-01 1.00516 0.00431 pust014_case_4 0.99800 0.00320 220 1.00406 0.00033 1.65E-01 1.00607 0.00322 pust014_case_5 0.99800 0.00320 220 1.00436 0.00034 1.64E-01 1.00637 0.00322 pust014_case_6 0.99800 0.00320 220 1.00401 0.00031 1.64E-01 1.00602 0.00321 pust014_case_7 0.99800 0.00320 220 1.00426 0.00030 1.66E-01 1.00627 0.00321 pust014_case_8 0.99800 0.00320 220 1.00281 0.00041 1.65E-01 1.00482 0.00323 pust014_case_9 0.99800 0.00320 220 1.00315 0.00035 1.65E-01 1.00516 0.00322 pust015_case_1 0.99800 0.00380 163 1.00493 0.00032 2.33E-01 1.00694 0.00381 pust015_case_10 0.99710 0.00470 163 1.00339 0.00035 2.32E-01 1.00631 0.00471 pust015_case_11 0.99710 0.00470 163 1.00257 0.00031 2.34E-01 1.00549 0.00471 pust015_case_12 0.99710 0.00470 163 1.00386 0.00034 2.33E-01 1.00678 0.00471 pust015_case_13 0.99710 0.00470 163 1.00446 0.00032 2.32E-01 1.00738 0.00471 pust015_case_14 0.99710 0.00470 163 1.00525 0.00031 2.32E-01 1.00817 0.00471 pust015_case_15 0.99710 0.00470 163 1.00781 0.00032 2.35E-01 1.01074 0.00471 pust015_case_16 0.99710 0.00470 163 1.00438 0.00037 2.34E-01 1.00730 0.00471 pust015_case_17 0.99710 0.00470 163 1.00457 0.00031 2.33E-01 1.00749 0.00471 pust015_case_2 0.99800 0.00380 163 1.00564 0.00032 2.33E-01 1.00766 0.00381 pust015_case_3 0.99800 0.00380 163 1.00464 0.00033 2.32E-01 1.00665 0.00381 pust015_case_4 0.99800 0.00380 163 1.00588 0.00030 2.32E-01 1.00790 0.00381 pust015_case_5 0.99800 0.00380 163 1.00538 0.00030 2.32E-01 1.00739 0.00381 pust015_case_6 0.99800 0.00380 163 1.00657 0.00032 2.32E-01 1.00859 0.00381 pust015_case_7 0.99710 0.00470 163 1.00720 0.00030 2.34E-01 1.01013 0.00471 pust015_case_8 0.99710 0.00470 163 1.00518 0.00034 2.34E-01 1.00810 0.00471 pust015_case_9 0.99710 0.00470 163 1.00496 0.00033 2.33E-01 1.00788 0.00471 pust016_case_1 0.99800 0.00430 163 1.00430 0.00031 2.34E-01 1.00631 0.00431 pust016_case_10 0.99630 0.00330 220 1.00352 0.00030 1.64E-01 1.00725 0.00331 pust016_case_11 0.99630 0.00330 220 1.00416 0.00033 1.64E-01 1.00789 0.00332 pust016_case_2 0.99800 0.00430 163 1.00429 0.00031 2.33E-01 1.00630 0.00431 pust016_case_3 0.99800 0.00430 163 1.00570 0.00032 2.32E-01 1.00772 0.00431 pust016_case_4 0.99800 0.00430 163 1.00490 0.00034 2.32E-01 1.00691 0.00431 pust016_case_5 0.99690 0.00380 220 1.00344 0.00034 1.65E-01 1.00656 0.00382 pust016_case_6 0.99690 0.00380 220 1.00330 0.00031 1.65E-01 1.00642 0.00381
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
44 of 190 Experiment Calculation Normalized Case k_exp H/Pu k_calc EALF
[eV]
k_norm pust016_case_7 0.99690 0.00380 220 1.00377 0.00035 1.64E-01 1.00689 0.00382 pust016_case_8 0.99690 0.00380 220 1.00465 0.00031 1.65E-01 1.00777 0.00381 pust016_case_9 0.99630 0.00330 220 1.00343 0.00032 1.63E-01 1.00716 0.00332 pust017_case_1 0.99690 0.00380 220 1.00295 0.00034 1.64E-01 1.00607 0.00382 pust017_case_10 0.99690 0.00380 220 1.00271 0.00034 1.65E-01 1.00583 0.00382 pust017_case_11 0.99690 0.00380 220 1.00315 0.00031 1.64E-01 1.00627 0.00381 pust017_case_12 0.99690 0.00380 220 1.00400 0.00033 1.65E-01 1.00712 0.00381 pust017_case_13 0.99690 0.00380 220 1.00299 0.00033 1.65E-01 1.00611 0.00381 pust017_case_14 0.99690 0.00380 220 1.00416 0.00031 1.65E-01 1.00728 0.00381 pust017_case_15 0.99690 0.00380 220 1.00394 0.00031 1.64E-01 1.00706 0.00381 pust017_case_16 0.99690 0.00380 220 1.00410 0.00034 1.64E-01 1.00722 0.00382 pust017_case_17 0.99690 0.00380 220 1.00333 0.00031 1.65E-01 1.00645 0.00381 pust017_case_18 0.99690 0.00380 220 1.00340 0.00035 1.65E-01 1.00652 0.00382 pust017_case_2 0.99690 0.00380 220 1.00275 0.00032 1.65E-01 1.00587 0.00381 pust017_case_3 0.99690 0.00380 220 1.00301 0.00032 1.65E-01 1.00613 0.00381 pust017_case_4 0.99690 0.00380 220 1.00291 0.00033 1.65E-01 1.00603 0.00381 pust017_case_5 0.99690 0.00380 220 1.00286 0.00035 1.65E-01 1.00598 0.00382 pust017_case_6 0.99690 0.00380 220 1.00299 0.00031 1.65E-01 1.00611 0.00381 pust017_case_7 0.99690 0.00380 220 1.00257 0.00034 1.65E-01 1.00569 0.00382 pust017_case_8 0.99690 0.00380 220 1.00331 0.00030 1.64E-01 1.00643 0.00381 pust017_case_9 0.99690 0.00380 220 1.00306 0.00033 1.65E-01 1.00618 0.00381 pust020_case_1 1.00000 0.00590 635 1.00356 0.00029 6.55E-02 1.00356 0.00591 pust020_case_2 1.00000 0.00590 654 1.00554 0.00033 6.47E-02 1.00554 0.00591 pust020_case_3 1.00000 0.00590 786 1.00062 0.00027 5.89E-02 1.00062 0.00591 pust020_case_5 1.00000 0.00590 487 1.00400 0.00030 7.59E-02 1.00400 0.00591 pust020_case_6 1.00000 0.00590 476 1.00464 0.00028 7.88E-02 1.00464 0.00591 pust020_case_7 1.00000 0.00590 762 0.99782 0.00028 6.04E-02 0.99782 0.00591 pust020_case_8 1.00000 0.00590 361 1.00278 0.00032 1.05E-01 1.00278 0.00591 pust020_case_9 1.00000 0.00590 568 0.99505 0.00029 7.56E-02 0.99505 0.00591 pust021_case_10 1.00000 0.00250 1159 1.00566 0.00029 5.01E-02 1.00566 0.00252 pust021_case_7 1.00000 0.00320 702 1.00576 0.00028 6.59E-02 1.00576 0.00321 pust021_case_8 1.00000 0.00650 131 1.00300 0.00036 3.07E-01 1.00300 0.00651 pust021_case_9 1.00000 0.00320 667 1.00661 0.00028 6.78E-02 1.00661 0.00321 pust024_case_1 1.00000 0.00620 115 1.00322 0.00031 4.61E-01 1.00322 0.00621 pust024_case_10 1.00000 0.00530 190 1.00950 0.00033 2.22E-01 1.00950 0.00531 pust024_case_11 1.00000 0.00530 190 1.00796 0.00030 2.21E-01 1.00796 0.00531 pust024_case_12 1.00000 0.00530 190 1.00805 0.00030 2.20E-01 1.00805 0.00531 pust024_case_13 1.00000 0.00530 190 1.00719 0.00032 2.20E-01 1.00719 0.00531 pust024_case_14 1.00000 0.00530 161 1.00310 0.00032 2.95E-01 1.00310 0.00531 pust024_case_15 1.00000 0.00530 161 1.00329 0.00030 2.93E-01 1.00329 0.00531 pust024_case_16 1.00000 0.00530 161 1.00396 0.00031 2.90E-01 1.00396 0.00531 pust024_case_17 1.00000 0.00530 161 1.00454 0.00029 2.88E-01 1.00454 0.00531 pust024_case_18 1.00000 0.00510 484 1.00518 0.00029 8.92E-02 1.00518 0.00511 pust024_case_19 1.00000 0.00510 484 1.00644 0.00030 8.89E-02 1.00644 0.00511 pust024_case_2 1.00000 0.00620 115 1.00346 0.00030 4.54E-01 1.00346 0.00621 pust024_case_20 1.00000 0.00510 484 1.00604 0.00036 8.87E-02 1.00604 0.00511 pust024_case_21 1.00000 0.00510 484 1.00517 0.00028 8.84E-02 1.00517 0.00511
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
45 of 190 Experiment Calculation Normalized Case k_exp H/Pu k_calc EALF
[eV]
k_norm pust024_case_22 1.00000 0.00510 484 1.00474 0.00030 8.81E-02 1.00474 0.00511 pust024_case_23 1.00000 0.00510 484 1.00347 0.00027 8.82E-02 1.00347 0.00511 pust024_case_3 1.00000 0.00620 115 1.00281 0.00030 4.51E-01 1.00281 0.00621 pust024_case_4 1.00000 0.00620 115 1.00281 0.00033 4.49E-01 1.00281 0.00621 pust024_case_5 1.00000 0.00620 115 1.00204 0.00030 4.48E-01 1.00204 0.00621 pust024_case_6 1.00000 0.00770 59 1.00243 0.00035 1.64E+00 1.00243 0.00771 pust024_case_7 1.00000 0.00530 190 1.00880 0.00032 2.25E-01 1.00880 0.00531 pust024_case_8 1.00000 0.00530 190 1.00904 0.00032 2.24E-01 1.00904 0.00531 pust024_case_9 1.00000 0.00530 190 1.00890 0.00033 2.23E-01 1.00890 0.00531
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
46 of 190 4.3 AoA Margin 4.3.1 Beryllium Reflector Calculated keff values for cases from the 233ST015 benchmark experiment are shown in Table 4-4. The benchmark model keff for each case is 1.00000. In Figure 4-2, beryllium-reflected cases are plotted against EALF and compared to the average calculated keff of the four non-reflected cases in the benchmark set. Although there is a definite trend in the bias at higher EALF values, in the EALF range of interest in this application (0.046 to 0.071 eV), the trend suggests that the code is over-predicting reactivity relative to the non-Be reflected cases.
Considering this over-prediction in the EALF range of interest, and the low concentration of beryllium in the application considered here (1% by volume) no AoA margin is necessary.
Figure 4-2 Calculated keff Values for the Be-reflected 233ST015 Benchmark Set Compared to non-Be Average 0.960 0.965 0.970 0.975 0.980 0.985 0.990 0.995 1.000 0.000 0.200 0.400 0.600 0.800 1.000 1.200 1.400 1.600 Non-Be cases average Be cases Linear (Be cases)
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
47 of 190 Table 4-4 Experiments with and without Beryllium Reflector Benchmark Calculated Normalized Case keff keff ealf knorm Reflector
[eV]
233st015_case_1 1.00000 0.00750 0.98999 0.00034 1.103 0.98999 0.00751 Be 233st015_case_2 1.00000 0.00700 0.98567 0.00042 1.239 0.98567 0.00701 Be 233st015_case_3 1.00000 0.00680 0.98875 0.00037 0.717 0.98875 0.00681 Be 233st015_case_4 1.00000 0.00410 0.98875 0.00037 0.717 0.98875 0.00412 Be 233st015_case_5 1.00000 0.00550 0.98610 0.00038 1.372 0.98610 0.00551 Be 233st015_case_6 1.00000 0.00990 0.97711 0.00038 1.424 0.97711 0.00991 Be 233st015_case_7 1.00000 0.00700 0.98652 0.00037 0.788 0.98652 0.00701 Poly 233st015_case_8 1.00000 0.00670 0.97258 0.00037 1.463 0.97258 0.00671 Be 233st015_case_9 1.00000 0.00500 0.96846 0.00036 1.497 0.96846 0.00501 Be 233st015_case_10 1.00000 0.00510 0.98817 0.00037 1.134 0.98817 0.00511 Poly 233st015_case_11 1.00000 0.00750 0.99300 0.00035 0.693 0.99300 0.00751 Be 233st015_case_12 1.00000 0.00690 0.99386 0.00039 0.765 0.99386 0.00691 Be 233st015_case_13 1.00000 0.00690 0.99146 0.00035 0.810 0.99146 0.00691 Be 233st015_case_14 1.00000 0.00360 0.99816 0.00032 0.463 0.99816 0.00361 Be 233st015_case_15 1.00000 0.00600 0.98932 0.00035 0.847 0.98932 0.00601 Be 233st015_case_16 1.00000 0.00430 0.98880 0.00036 0.869 0.98880 0.00432 Be 233st015_case_17 1.00000 0.00290 0.99730 0.00036 0.502 0.99730 0.00292 Poly 233st015_case_18 1.00000 0.00560 0.97364 0.00036 0.901 0.97364 0.00561 Be 233st015_case_19 1.00000 0.00520 0.97453 0.00037 0.915 0.97453 0.00521 Be 233st015_case_20 1.00000 0.00790 0.99488 0.00036 0.289 0.99488 0.00791 Be 233st015_case_21 1.00000 0.00700 0.99845 0.00037 0.316 0.99845 0.00701 Be 233st015_case_22 1.00000 0.00620 0.99613 0.00038 0.330 0.99613 0.00621 Be 233st015_case_23 1.00000 0.00550 0.99421 0.00038 0.343 0.99421 0.00551 Be 233st015_case_24 1.00000 0.00510 0.99104 0.00034 0.351 0.99104 0.00511 Be 233st015_case_25 1.00000 0.00230 0.99758 0.00033 0.222 0.99758 0.00232 Poly 233st015_case_26 1.00000 0.00660 0.99475 0.00034 0.126 0.99475 0.00661 Be 233st015_case_27 1.00000 0.00630 0.99866 0.00034 0.131 0.99866 0.00631 Be 233st015_case_28 1.00000 0.00580 0.99675 0.00034 0.133 0.99675 0.00581 Be 233st015_case_29 1.00000 0.00510 0.99533 0.00034 0.135 0.99533 0.00511 Be 233st015_case_30 1.00000 0.00480 0.99454 0.00034 0.137 0.99454 0.00481 Be 233st015_case_31 1.00000 0.00550 0.99399 0.00037 0.138 0.99399 0.00551 Be
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
48 of 190 4.3.2 Lead Reflector Because the shielded containers have a lead wall, thermal benchmarks for lead-reflected Pu systems are also desired. As no such benchmarks are available, eight lead-reflected low-enriched uranium (LEU) benchmarks are analyzed and compared to identical experiments with no lead reflector or strong absorber. Table 4-5 shows calculated and normalized keff values for the lead-reflected cases from LEU-COMP-THERM-010 and for cases from LEU-COMP-THERM-009 and -010 with no strong absorbers present (cases with steel, aluminum, and Zircaloy-4). The EALF range of the non-lead experiments (0.11 - 0.31 eV) is consistent with that of the lead experiments (0.11 - 0.30 eV).
The average knorm value for the lead-reflected cases (1.00320) is higher than that of the non-lead cases (1.00025). Hence, relative to the non-lead cases, SCALE v6.2.3 tends to overpredict reactivity when lead is present. Hence, no AoA margin is necessary.
Table 4-5 Experiments with and without Lead Reflector Benchmark Calculated Normalized Case kbench kcalc knorm Reflector LCT-010-01 1.00000 0.00210 1.00530 0.00027 1.00530 0.00212 Pb LCT-010-02 1.00000 0.00210 1.00576 0.00027 1.00576 0.00212 Pb LCT-010-03 1.00000 0.00210 1.00439 0.00026 1.00439 0.00212 Pb LCT-010-04 1.00000 0.00210 0.99672 0.00029 0.99672 0.00212 Pb LCT-010-20 1.00000 0.00280 1.00387 0.00027 1.00387 0.00281 Pb LCT-010-21 1.00000 0.00280 1.00416 0.00028 1.00416 0.00281 Pb LCT-010-22 1.00000 0.00280 1.00344 0.00025 1.00344 0.00281 Pb LCT-010-23 1.00000 0.00280 1.00196 0.00026 1.00196 0.00281 Pb LCT-010-09 1.00000 0.00210 0.99969 0.00027 0.99969 0.00212 Steel LCT-010-10 1.00000 0.00210 1.00033 0.00025 1.00033 0.00211 Steel LCT-010-11 1.00000 0.00210 1.00090 0.00028 1.00090 0.00212 Steel LCT-010-12 1.00000 0.00210 0.99966 0.00028 0.99966 0.00212 Steel LCT-010-13 1.00000 0.00210 0.99752 0.00024 0.99752 0.00211 Steel LCT-010-14 1.00000 0.00280 1.00221 0.00029 1.00221 0.00281 Steel LCT-010-15 1.00000 0.00280 1.00217 0.00027 1.00217 0.00281 Steel LCT-010-16 1.00000 0.00280 1.00302 0.00028 1.00302 0.00281 Steel LCT-010-17 1.00000 0.00280 1.00281 0.00028 1.00281 0.00281 Steel LCT-010-18 1.00000 0.00280 1.00255 0.00025 1.00255 0.00281 Steel LCT-010-19 1.00000 0.00280 1.00239 0.00026 1.00239 0.00281 Steel LCT-009-01 1.00000 0.00210 0.99883 0.00024 0.99883 0.00211 Steel LCT-009-02 1.00000 0.00210 0.99913 0.00028 0.99913 0.00212 Steel LCT-009-03 1.00000 0.00210 0.99839 0.00028 0.99839 0.00212 Steel LCT-009-04 1.00000 0.00210 0.99942 0.00026 0.99942 0.00212 Steel LCT-009-24 1.00000 0.00210 0.99838 0.00026 0.99838 0.00212 Aluminum LCT-009-25 1.00000 0.00210 0.99900 0.00025 0.99900 0.00211 Aluminum LCT-009-26 1.00000 0.00210 0.99910 0.00027 0.99910 0.00212 Zircaloy-4 LCT-009-27 1.00000 0.00210 0.99926 0.00024 0.99926 0.00211 Zircaloy-4
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
49 of 190 4.4 USL Determination The USL is calculated to be 0.9375 (conservatively rounded down from calculated value of 0.93756) as shown in Table 4-6 and determined by the following formula USL = 1 - (Bias+Bias Uncertainty) - Administrative Margin - AoA Margin Table 4-6 Calculation of USL Benchmark Set Number of Cases Bias and Bias Uncertainty Administrative Margin AoA Margin USL Pu 196 0.01244 0.05 0.00 0.9375
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
50 of 190
5.0 REFERENCES
[1]
Title 10, Code of Federal Regulations, Part 71 (10 CFR 71), Packaging and Transportation of Radioactive Material.
[2]
U.S. Department of Energy (DOE), Contact-Handled Transuranic Waste Authorized Methods for Payload Control(CH-TRAMPAC), U.S. Department of Energy, Carlsbad Field Office, Carlsbad, New Mexico, Revision 4, March 2013.
[3]
Neeley, G. W., D. L. Newell, S. L. Larson, and R. J. Green, Reactivity Effects of Moderator and Reflector Materials on a Finite Plutonium System, SAIC-1322-001, Revision 1, Science Applications International Corporation, Oak Ridge, Tennessee, May 2004.
[4]
WP 08-PT.09, Test Plan to Determine the TRU Waste Polyethylene Packing Fraction, Washington TRU Solutions, LLC., Revision 0, June 2003.
[5]
B. T. Rearden and M. A. Jessee, ed., SCALE Code System, ORNL/TM-2005/39 Version 6.2.3, March 2018.
[6]
HalfPACT Safety Analysis Report, Rev. 7, August 2020.
[7]
NWP, LLC, 30G2 Shielded Container SAR Drawing, Drawing 163-010 Rev 0.
[8]
NWP, LLC, 30G3 Shielded Container SAR Drawing, Drawing 163-011 Rev 0.
[9]
NWP, LLC, 55G1 Shielded Container SAR Drawing, Drawing 163-012 Rev 0.
[10] NWP, LLC, 55G2 Shielded Container SAR Drawing, Drawing 163-013 Rev 0.
[11] Organization for Economic Cooperation and Development, International Handbook of Evaluated Criticality Safety Benchmark Experiments, NEA/NCS/DOC (95)03, September 2016.
[12] J. C. Dean, R. W. Tayloe, Guide for Validation of Nuclear Criticality Safety Calculational Methodology, NUREG/CR-6698, January 2001.
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
51 of 190 6.0 APPENDIX 6.1 Sample Models Case G Limiting HAC Array Model - Input file dj_ha325a1c33g1s0900hx.inp
=csas5 HAC Array SC-30G3 A1 mass(325) mod(PolyWater) hx(900) pay(Corner) rot(00)
' Case Data
' Model Revision v1.2
' Model HAC Array
' Library ce_v7.1_endf
' Materials
' Model Master ID Description
' Fissile Fissile 1 Pu+PolyWater mass(325) htox(900) rho(1.0086)
' Ambient Air 3 Air (Dry, Near Sea Level)
' SCShell CarbonSteel 5 Scale SCL Carbon Steel
' SCCavity PolyWaterBeVF1 20 Poly(25%) Water(74%) Be(1%) vf(1.00) rho(0.9879)
' Payload PolyWaterBeVF1 20 Poly(25%) Water(74%) Be(1%) vf(1.00) rho(0.9879)
' IOCV SS304 6 Scale SCL SS304
' Foam Air 3 Air (Dry, Near Sea Level)
' OCA SS304 6 Scale SCL SS304
' Fissile
' H/X 900.00
' Fissile material Pu
' Fissile mass 325.00 [g]
' ICV reflector PolyWaterBeVF1
' OCA reflector Air
' Inside reflector vol frac 1.00
' Outside reflector Air
' Outside reflector thickness 0.00 [cm]
' Outside reflector vol frac 1.00
' Configuration
' Config ID A1
' Config description 1 SC - Sphere Corner SC 1 - Payload Corner - rotated 0 deg
' Container SC-30G3
' Sphere Location Outside
' Payload location Corner
' Payload rotation 0 [deg]
ce_v7.1_endf read composition
' Master materials
' Pu+PolyWater mass(325) htox(900) rho(1.0086) pu-239 1 0 7.75076E-05 300 end h-1 1 0 4.99683E-02 300 end h-poly 1 0 1.97805E-02 300 end h-2 1 0 8.02203E-06 300 end c 1 0 9.89137E-03 300 end o-16 1 0 2.49775E-02 300 end o-17 1 0 9.49507E-06 300 end
' Air (Dry, Near Sea Level)
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
52 of 190 c 3 0 7.82159E-09 300 end n-14 3 0 3.93296E-05 300 end n-15 3 0 1.43683E-07 300 end o-16 3 0 1.06009E-05 300 end o-17 3 0 4.02988E-09 300 end
' Scale SCL Carbon Steel c 5 0 3.92142E-03 300 end fe-54 5 0 4.88044E-03 300 end fe-56 5 0 7.66124E-02 300 end fe-57 5 0 1.76931E-03 300 end fe-58 5 0 2.35463E-04 300 end
' Lead pb-204 4 0 4.61551E-04 300 end pb-206 4 0 7.94528E-03 300 end pb-207 4 0 7.28592E-03 300 end pb-208 4 0 1.72752E-02 300 end
' Poly(25%) Water(74%) Be(1%) vf(1.00) rho(0.9879) h-1 20 0 4.93786E-02 300 end h-poly 20 0 1.98112E-02 300 end h-2 20 0 7.95775E-06 300 end c 20 0 9.90673E-03 300 end o-16 20 0 2.46828E-02 300 end o-17 20 0 9.38302E-06 300 end bebound 20 0 1.23621E-03 300 end
' Scale SCL SS304 c 6 0 3.18479E-04 300 end si-28 6 0 1.57010E-03 300 end si-29 6 0 7.97625E-05 300 end si-30 6 0 5.26416E-05 300 end p-31 6 0 6.94688E-05 300 end cr-50 6 0 7.59178E-04 300 end cr-52 6 0 1.46400E-02 300 end cr-53 6 0 1.66006E-03 300 end cr-54 6 0 4.13224E-04 300 end mn-55 6 0 1.74072E-03 300 end fe-54 6 0 3.42190E-03 300 end fe-56 6 0 5.37166E-02 300 end fe-57 6 0 1.24055E-03 300 end fe-58 6 0 1.65094E-04 300 end ni-58 6 0 5.26874E-03 300 end ni-60 6 0 2.02950E-03 300 end ni-61 6 0 8.82212E-05 300 end ni-62 6 0 2.81296E-04 300 end ni-64 6 0 7.16280E-05 300 end end composition read param gen= 1100 npg= 10000 nsk= 100 htm= no plt= no run= yes end param read geom unit 1 com='SC-30G3 fissile' sphere 1 1 13.6114 orig 24.1328 0.0000 12.3091 xcylinder 20 1 25.9207 37.7444 -37.7444 xcylinder 5 1 27.1907 42.1894 -42.1640 xcylinder 4 1 34.2900 48.0060 -48.5394 xcylinder 5 1 35.5600 54.9910 -52.3494 hole 4 52.6313 0.0000 0.0000 unit 2 com='SC-30G3 empty' xcylinder 20 1 25.9207 37.7444 -37.7444 xcylinder 5 1 27.1907 42.1894 -42.1640 xcylinder 4 1 34.2900 48.0060 -48.5394 xcylinder 5 1 35.5600 54.9910 -52.3494 hole 4 52.6313 0.0000 0.0000
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
53 of 190 unit 4 com='lid lead ring' xcylinder 5 1 22.5425 1.9050 0.0000 xcylinder 4 1 29.8450 1.9050 0.0000
' 1 SC - Sphere Corner SC 1 - Payload Corner - rotated 0 deg global unit 5 com='halfpact' zcylinder 20 1 97.07563 57.0706 -57.0706 hole 1 35.3370 0.0000 21.5105 zcylinder 6 1 98.18688 58.3406 -58.3406 zcylinder 3 1 110.88688 71.0406 -71.0406 zcylinder 6 1 111.52188 71.6756 -71.6756 cuboid 3 1 4p111.5219 2p71.6756 end geom read bounds xfc= reflect yfc= reflect zfc= reflect end bounds read start nst= 0 end start end data end
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
54 of 190 6.2 List of Files on Attachment 1
- SCA-CAL01 Rev 0 Attachment 1
- Directories: 436, Files: 9,666, Size: 3,023,366,208 B Name Size Last write date CRC32
\\Excel\\ (1) 1,522,185 11-25-2019 09:41 ShieldedContainer_v1208c_Results.xlsx 1,661,457 01-10-2020 09:07 79aeb3b7
\\v1.2\\ (0) 2,829,627,557 11-23-2019 18:04
\\v1.2\\ba\\ (0) 45,134,803 11-18-2019 16:50
\\v1.2\\ba\\ha245\\ (22) 5,553,916 11-18-2019 20:33 ba_ha245a0c00g0s0500hx.inp 3,859 11-18-2019 09:36 6dc7fbd5 ba_ha245a0c00g0s0500hx.out 500,749 11-18-2019 14:03 533b8032 ba_ha245a0c00g0s0600hx.inp 3,860 11-18-2019 09:36 e24abc12 ba_ha245a0c00g0s0600hx.out 500,501 11-18-2019 13:55 6e82a8b8 ba_ha245a0c00g0s0700hx.inp 3,860 11-18-2019 09:36 a8158ae1 ba_ha245a0c00g0s0700hx.out 501,031 11-18-2019 13:56 1ec1a6d6 ba_ha245a0c00g0s0800hx.inp 3,860 11-18-2019 09:36 78134968 ba_ha245a0c00g0s0800hx.out 500,742 11-18-2019 13:52 fdf6d0a8 ba_ha245a0c00g0s0900hx.inp 3,860 11-18-2019 09:36 95b269e5 ba_ha245a0c00g0s0900hx.out 501,234 11-18-2019 13:48 69764b10 ba_ha245a0c00g0s1000hx.inp 3,864 11-18-2019 09:36 addb7d31 ba_ha245a0c00g0s1000hx.out 500,832 11-18-2019 13:47 ac0aac60 ba_ha245a0c00g0s1100hx.inp 3,864 11-18-2019 09:36 7a13ae9e ba_ha245a0c00g0s1100hx.out 500,499 11-18-2019 13:45 74de9380 ba_ha245a0c00g0s1200hx.inp 3,864 11-18-2019 09:36 552b5555 ba_ha245a0c00g0s1200hx.out 501,588 11-18-2019 13:45 8acdf6d3 ba_ha245a0c00g0s1300hx.inp 3,864 11-18-2019 09:36 62c9b9a0 ba_ha245a0c00g0s1300hx.out 501,443 11-18-2019 13:46 abdba730 ba_ha245a0c00g0s1400hx.inp 3,864 11-18-2019 09:36 9d0c37c2 ba_ha245a0c00g0s1400hx.out 501,020 11-18-2019 13:46 72886334 ba_ha245a0c00g0s1500hx.inp 3,864 11-18-2019 09:37 c46817c6 ba_ha245a0c00g0s1500hx.out 501,794 11-18-2019 13:47 69f2b571
\\v1.2\\ba\\ha325\\ (22) 6,274,348 11-18-2019 20:33 ba_ha325a0c00g0s0500hx.inp 3,778 11-18-2019 00:02 69b56f69 ba_ha325a0c00g0s0500hx.out 500,138 11-18-2019 04:10 60e2c6cf ba_ha325a0c00g0s0600hx.inp 3,778 11-18-2019 00:02 31c15fe7 ba_ha325a0c00g0s0600hx.out 500,709 11-18-2019 04:05 30741a6f ba_ha325a0c00g0s0700hx.inp 3,778 11-18-2019 00:02 4f08563a ba_ha325a0c00g0s0700hx.out 500,145 11-18-2019 04:01 81dee71a ba_ha325a0c00g0s0800hx.inp 3,778 11-18-2019 00:02 0fea1af2 ba_ha325a0c00g0s0800hx.out 499,352 11-18-2019 04:01 fe8cb6e4 ba_ha325a0c00g0s0900hx.inp 3,778 11-18-2019 00:02 f541f1bf ba_ha325a0c00g0s0900hx.out 500,377 11-18-2019 04:02 86279eba ba_ha325a0c00g0s1000hx.inp 3,782 11-18-2019 00:02 525dc788 ba_ha325a0c00g0s1000hx.out 500,118 11-18-2019 04:03 d2cd4498 ba_ha325a0c00g0s1100hx.inp 3,782 11-18-2019 00:02 eb37f2f6 ba_ha325a0c00g0s1100hx.out 646,361 11-18-2019 03:57 51e723ea ba_ha325a0c00g0s1200hx.inp 3,782 11-18-2019 00:02 0a5f632c ba_ha325a0c00g0s1200hx.out 646,231 11-18-2019 03:57 025e22f4 ba_ha325a0c00g0s1300hx.inp 3,782 11-18-2019 00:02 86831f07 ba_ha325a0c00g0s1300hx.out 646,636 11-18-2019 03:52 f7130b02 ba_ha325a0c00g0s1400hx.inp 3,782 11-18-2019 00:02 e9cc75dc ba_ha325a0c00g0s1400hx.out 645,937 11-18-2019 03:53 ebf9bc77 ba_ha325a0c00g0s1500hx.inp 3,782 11-18-2019 00:02 12e52d7a ba_ha325a0c00g0s1500hx.out 646,762 11-18-2019 02:27 068df34f
\\v1.2\\ba\\hs245\\ (22) 5,556,703 11-20-2019 09:22 ba_hs245a0c00g0s0500hx.inp 3,860 11-18-2019 14:19 324d840a ba_hs245a0c00g0s0500hx.out 501,800 11-19-2019 17:00 226dd72b ba_hs245a0c00g0s0600hx.inp 3,861 11-18-2019 14:19 800dfa4f ba_hs245a0c00g0s0600hx.out 500,758 11-19-2019 16:56 c9b91934 ba_hs245a0c00g0s0700hx.inp 3,861 11-18-2019 14:19 c3f13512 ba_hs245a0c00g0s0700hx.out 500,607 11-19-2019 16:49 12b618c5 ba_hs245a0c00g0s0800hx.inp 3,861 11-18-2019 14:19 fc6faac3 ba_hs245a0c00g0s0800hx.out 501,335 11-19-2019 16:47 acf3b3f2
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
55 of 190 ba_hs245a0c00g0s0900hx.inp 3,861 11-18-2019 14:19 64a3f8c5 ba_hs245a0c00g0s0900hx.out 500,740 11-19-2019 16:49 6d033a39 ba_hs245a0c00g0s1000hx.inp 3,865 11-18-2019 14:19 0effce04 ba_hs245a0c00g0s1000hx.out 501,901 11-19-2019 16:33 b291e90b ba_hs245a0c00g0s1100hx.inp 3,865 11-18-2019 14:19 24047fb0 ba_hs245a0c00g0s1100hx.out 501,630 11-19-2019 16:45 d4000172 ba_hs245a0c00g0s1200hx.inp 3,865 11-18-2019 14:19 529e18fe ba_hs245a0c00g0s1200hx.out 500,750 11-19-2019 16:52 fb018a72 ba_hs245a0c00g0s1300hx.inp 3,865 11-18-2019 14:19 93ef7f9e ba_hs245a0c00g0s1300hx.out 502,145 11-19-2019 16:46 c4878f86 ba_hs245a0c00g0s1400hx.inp 3,865 11-18-2019 14:19 2eea8591 ba_hs245a0c00g0s1400hx.out 500,446 11-19-2019 16:52 f36bd7cb ba_hs245a0c00g0s1500hx.inp 3,865 11-18-2019 14:20 b798d40e ba_hs245a0c00g0s1500hx.out 502,097 11-19-2019 16:47 320f70a4
\\v1.2\\ba\\hs325\\ (22) 5,544,494 11-20-2019 09:22 ba_hs325a0c00g0s0500hx.inp 3,811 11-18-2019 12:31 bd6c1e12 ba_hs325a0c00g0s0500hx.out 500,586 11-19-2019 12:00 7f5e066d ba_hs325a0c00g0s0600hx.inp 3,811 11-18-2019 12:31 bc19f137 ba_hs325a0c00g0s0600hx.out 500,140 11-19-2019 11:58 3ddbfd08 ba_hs325a0c00g0s0700hx.inp 3,811 11-18-2019 12:31 bfcf7494 ba_hs325a0c00g0s0700hx.out 500,412 11-19-2019 11:53 27f9cf27 ba_hs325a0c00g0s0800hx.inp 3,811 11-18-2019 12:31 44c3bfab ba_hs325a0c00g0s0800hx.out 500,492 11-19-2019 12:04 75d35143 ba_hs325a0c00g0s0900hx.inp 3,811 11-18-2019 12:32 3680e5b0 ba_hs325a0c00g0s0900hx.out 500,327 11-19-2019 11:49 780535ec ba_hs325a0c00g0s1000hx.inp 3,815 11-18-2019 12:32 635fd5bc ba_hs325a0c00g0s1000hx.out 500,724 11-19-2019 11:48 be0294d6 ba_hs325a0c00g0s1100hx.inp 3,815 11-18-2019 12:32 bac5c2ec ba_hs325a0c00g0s1100hx.out 499,174 11-19-2019 11:54 1ecfa3be ba_hs325a0c00g0s1200hx.inp 3,815 11-18-2019 12:32 ab82bd6e ba_hs325a0c00g0s1200hx.out 500,184 11-19-2019 11:39 7b7dc7fc ba_hs325a0c00g0s1300hx.inp 3,815 11-18-2019 12:32 734da85b ba_hs325a0c00g0s1300hx.out 499,716 11-19-2019 11:49 ac385699 ba_hs325a0c00g0s1400hx.inp 3,815 11-18-2019 12:32 21bd7a67 ba_hs325a0c00g0s1400hx.out 500,330 11-19-2019 12:03 47cd77fb ba_hs325a0c00g0s1500hx.inp 3,815 11-18-2019 12:32 e782f577 ba_hs325a0c00g0s1500hx.out 500,464 11-19-2019 11:57 d05dde38
\\v1.2\\ba\\na245\\ (22) 5,556,427 11-20-2019 09:22 ba_na245a0c00g0s0500hx.inp 3,859 11-18-2019 11:08 0fdebc39 ba_na245a0c00g0s0500hx.out 500,598 11-19-2019 04:07 22221244 ba_na245a0c00g0s0600hx.inp 3,860 11-18-2019 11:08 aed0760e ba_na245a0c00g0s0600hx.out 501,472 11-19-2019 04:08 f400babc ba_na245a0c00g0s0700hx.inp 3,860 11-18-2019 11:08 e48f40fd ba_na245a0c00g0s0700hx.out 501,449 11-19-2019 04:08 5b5c1f60 ba_na245a0c00g0s0800hx.inp 3,860 11-18-2019 11:08 34898374 ba_na245a0c00g0s0800hx.out 501,162 11-19-2019 03:55 064ff681 ba_na245a0c00g0s0900hx.inp 3,860 11-18-2019 11:08 d928a3f9 ba_na245a0c00g0s0900hx.out 501,434 11-19-2019 04:04 72156884 ba_na245a0c00g0s1000hx.inp 3,864 11-18-2019 11:08 f9031b44 ba_na245a0c00g0s1000hx.out 501,398 11-19-2019 03:56 6323a5f9 ba_na245a0c00g0s1100hx.inp 3,864 11-18-2019 11:08 2ecbc8eb ba_na245a0c00g0s1100hx.out 500,918 11-19-2019 03:51 7cc4e333 ba_na245a0c00g0s1200hx.inp 3,864 11-18-2019 11:08 01f33320 ba_na245a0c00g0s1200hx.out 500,881 11-19-2019 03:53 24842b37 ba_na245a0c00g0s1300hx.inp 3,864 11-18-2019 11:08 3611dfd5 ba_na245a0c00g0s1300hx.out 501,529 11-19-2019 03:56 c0a38c2c ba_na245a0c00g0s1400hx.inp 3,864 11-18-2019 11:09 c9d451b7 ba_na245a0c00g0s1400hx.out 501,763 11-19-2019 03:38 551d9c58 ba_na245a0c00g0s1500hx.inp 3,864 11-18-2019 11:09 90b071b3 ba_na245a0c00g0s1500hx.out 501,340 11-19-2019 04:01 b0f517e5
\\v1.2\\ba\\na325\\ (22) 5,547,436 11-20-2019 09:22 ba_na325a0c00g0s0500hx.inp 3,810 11-18-2019 10:06 7b494625 ba_na325a0c00g0s0500hx.out 500,616 11-18-2019 20:24 26821d47 ba_na325a0c00g0s0600hx.inp 3,810 11-18-2019 10:06 960fdd6c ba_na325a0c00g0s0600hx.out 500,078 11-18-2019 20:14 8b483acd ba_na325a0c00g0s0700hx.inp 3,810 11-18-2019 10:06 1c55fd45 ba_na325a0c00g0s0700hx.out 500,909 11-18-2019 20:12 0a67817e ba_na325a0c00g0s0800hx.inp 3,810 11-18-2019 10:06 dbd191d1 ba_na325a0c00g0s0800hx.out 500,180 11-18-2019 20:14 8a40ae7d ba_na325a0c00g0s0900hx.inp 3,810 11-18-2019 10:07 5aaae204 ba_na325a0c00g0s0900hx.out 500,352 11-18-2019 19:58 7b699cea ba_na325a0c00g0s1000hx.inp 3,814 11-18-2019 10:07 e295bef2 ba_na325a0c00g0s1000hx.out 500,657 11-18-2019 19:58 b335cee3 ba_na325a0c00g0s1100hx.inp 3,814 11-18-2019 10:07 a2e31649 ba_na325a0c00g0s1100hx.out 499,672 11-18-2019 20:09 930e3759
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
56 of 190 ba_na325a0c00g0s1200hx.inp 3,814 11-18-2019 10:07 674c55d8 ba_na325a0c00g0s1200hx.out 500,378 11-18-2019 20:08 be99411f ba_na325a0c00g0s1300hx.inp 3,814 11-18-2019 10:07 be289fd0 ba_na325a0c00g0s1300hx.out 501,108 11-18-2019 19:55 c56e1e1b ba_na325a0c00g0s1400hx.inp 3,814 11-18-2019 10:07 6be7bf82 ba_na325a0c00g0s1400hx.out 500,410 11-18-2019 20:25 b8a7ab69 ba_na325a0c00g0s1500hx.inp 3,814 11-18-2019 10:07 346ee0ad ba_na325a0c00g0s1500hx.out 501,142 11-18-2019 19:58 71308d2b
\\v1.2\\ba\\ns245\\ (22) 5,555,173 11-20-2019 09:22 ba_ns245a0c00g0s0500hx.inp 3,860 11-18-2019 16:50 8423fdda ba_ns245a0c00g0s0500hx.out 500,985 11-20-2019 03:33 9b77f59e ba_ns245a0c00g0s0600hx.inp 3,861 11-18-2019 16:50 34814b4d ba_ns245a0c00g0s0600hx.out 501,355 11-20-2019 03:37 ac9d4339 ba_ns245a0c00g0s0700hx.inp 3,861 11-18-2019 16:50 777d8410 ba_ns245a0c00g0s0700hx.out 500,846 11-20-2019 03:26 ce93921d ba_ns245a0c00g0s0800hx.inp 3,861 11-18-2019 16:51 48e31bc1 ba_ns245a0c00g0s0800hx.out 500,816 11-20-2019 03:29 736b77ee ba_ns245a0c00g0s0900hx.inp 3,861 11-18-2019 16:51 d02f49c7 ba_ns245a0c00g0s0900hx.out 501,052 11-20-2019 03:21 f88c0661 ba_ns245a0c00g0s1000hx.inp 3,865 11-18-2019 16:51 685f4a27 ba_ns245a0c00g0s1000hx.out 501,812 11-20-2019 03:20 f54bc57c ba_ns245a0c00g0s1100hx.inp 3,865 11-18-2019 16:51 42a4fb93 ba_ns245a0c00g0s1100hx.out 500,941 11-20-2019 03:23 5a05c20d ba_ns245a0c00g0s1200hx.inp 3,865 11-18-2019 16:51 343e9cdd ba_ns245a0c00g0s1200hx.out 501,321 11-20-2019 03:21 c166377e ba_ns245a0c00g0s1300hx.inp 3,865 11-18-2019 16:51 f54ffbbd ba_ns245a0c00g0s1300hx.out 501,162 11-20-2019 03:31 6f279055 ba_ns245a0c00g0s1400hx.inp 3,865 11-18-2019 16:51 484a01b2 ba_ns245a0c00g0s1400hx.out 501,053 11-20-2019 03:22 3fc73d10 ba_ns245a0c00g0s1500hx.inp 3,865 11-18-2019 16:51 d138502d ba_ns245a0c00g0s1500hx.out 501,336 11-20-2019 03:37 ddd5c2bc
\\v1.2\\ba\\ns325\\ (22) 5,546,306 11-20-2019 09:22 ba_ns325a0c00g0s0500hx.inp 3,811 11-18-2019 15:46 26204153 ba_ns325a0c00g0s0500hx.out 500,557 11-19-2019 22:20 3357b674 ba_ns325a0c00g0s0600hx.inp 3,811 11-18-2019 15:46 2755ae76 ba_ns325a0c00g0s0600hx.out 501,930 11-19-2019 22:14 33cfdc38 ba_ns325a0c00g0s0700hx.inp 3,811 11-18-2019 15:46 24832bd5 ba_ns325a0c00g0s0700hx.out 500,296 11-19-2019 22:07 2a601735 ba_ns325a0c00g0s0800hx.inp 3,811 11-18-2019 15:46 df8fe0ea ba_ns325a0c00g0s0800hx.out 500,234 11-19-2019 22:17 fa611c7a ba_ns325a0c00g0s0900hx.inp 3,811 11-18-2019 15:46 adccbaf1 ba_ns325a0c00g0s0900hx.out 499,870 11-19-2019 22:10 388c057c ba_ns325a0c00g0s1000hx.inp 3,815 11-18-2019 15:46 e5cab901 ba_ns325a0c00g0s1000hx.out 500,154 11-19-2019 22:10 1e3ca799 ba_ns325a0c00g0s1100hx.inp 3,815 11-18-2019 15:46 3c50ae51 ba_ns325a0c00g0s1100hx.out 500,222 11-19-2019 22:16 c0ddfc14 ba_ns325a0c00g0s1200hx.inp 3,815 11-18-2019 15:47 2d17d1d3 ba_ns325a0c00g0s1200hx.out 500,258 11-19-2019 22:16 bc3469cf ba_ns325a0c00g0s1300hx.inp 3,815 11-18-2019 15:47 f5d8c4e6 ba_ns325a0c00g0s1300hx.out 500,447 11-19-2019 22:10 db18dae3 ba_ns325a0c00g0s1400hx.inp 3,815 11-18-2019 15:47 a72816da ba_ns325a0c00g0s1400hx.out 500,353 11-19-2019 22:18 729f4f85 ba_ns325a0c00g0s1500hx.inp 3,815 11-18-2019 15:47 611799ca ba_ns325a0c00g0s1500hx.out 500,040 11-19-2019 22:16 4b67f160
\\v1.2\\bb\\ (0) 57,278,433 11-18-2019 16:51
\\v1.2\\bb\\ha245\\ (22) 7,165,947 11-18-2019 20:33 bb_ha245a0c00g0s0500hx.inp 3,834 11-18-2019 01:55 24fc1f30 bb_ha245a0c00g0s0500hx.out 647,442 11-18-2019 13:35 ef43f0c7 bb_ha245a0c00g0s0600hx.inp 3,835 11-18-2019 01:55 cfbb460a bb_ha245a0c00g0s0600hx.out 646,620 11-18-2019 13:29 bb4f399f bb_ha245a0c00g0s0700hx.inp 3,835 11-18-2019 01:55 77e279a2 bb_ha245a0c00g0s0700hx.out 647,606 11-18-2019 13:26 ed523c97 bb_ha245a0c00g0s0800hx.inp 3,835 11-18-2019 01:55 27459360 bb_ha245a0c00g0s0800hx.out 647,795 11-18-2019 13:24 17863bef bb_ha245a0c00g0s0900hx.inp 3,835 11-18-2019 01:55 0be8b43c bb_ha245a0c00g0s0900hx.out 647,246 11-18-2019 13:29 9c84974d bb_ha245a0c00g0s1000hx.inp 3,839 11-18-2019 01:56 bb719b3e bb_ha245a0c00g0s1000hx.out 647,555 11-18-2019 13:26 7231cb7f bb_ha245a0c00g0s1100hx.inp 3,839 11-18-2019 01:56 76e16f73 bb_ha245a0c00g0s1100hx.out 647,908 11-18-2019 13:27 2488e902 bb_ha245a0c00g0s1200hx.inp 3,839 11-18-2019 01:56 92f3fb80 bb_ha245a0c00g0s1200hx.out 647,702 11-18-2019 13:26 288a6e3e bb_ha245a0c00g0s1300hx.inp 3,839 11-18-2019 01:56 83814887
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
57 of 190 bb_ha245a0c00g0s1300hx.out 648,067 11-18-2019 13:29 28e70319 bb_ha245a0c00g0s1400hx.inp 3,839 11-18-2019 01:56 64966140 bb_ha245a0c00g0s1400hx.out 648,015 11-18-2019 13:29 b147b859 bb_ha245a0c00g0s1500hx.inp 3,839 11-18-2019 01:56 bfadab3d bb_ha245a0c00g0s1500hx.out 647,783 11-18-2019 13:32 fc299223
\\v1.2\\bb\\ha325\\ (22) 7,155,064 11-18-2019 20:33 bb_ha325a0c00g0s0500hx.inp 3,780 11-18-2019 00:02 a811ba56 bb_ha325a0c00g0s0500hx.out 647,764 11-18-2019 03:47 0f1f820d bb_ha325a0c00g0s0600hx.inp 3,780 11-18-2019 00:03 bf8be351 bb_ha325a0c00g0s0600hx.out 647,588 11-18-2019 03:41 048c1ae1 bb_ha325a0c00g0s0700hx.inp 3,780 11-18-2019 00:03 5b9767dc bb_ha325a0c00g0s0700hx.out 645,216 11-18-2019 03:37 4a530ab6 bb_ha325a0c00g0s0800hx.inp 3,780 11-18-2019 00:03 7f05b205 bb_ha325a0c00g0s0800hx.out 646,206 11-18-2019 03:41 66fb8003 bb_ha325a0c00g0s0900hx.inp 3,780 11-18-2019 00:03 adae9e9e bb_ha325a0c00g0s0900hx.out 647,184 11-18-2019 03:37 f6346055 bb_ha325a0c00g0s1000hx.inp 3,784 11-18-2019 00:03 ed9c0a9e bb_ha325a0c00g0s1000hx.out 646,325 11-18-2019 03:38 f94eb586 bb_ha325a0c00g0s1100hx.inp 3,784 11-18-2019 00:03 4d0456df bb_ha325a0c00g0s1100hx.out 646,257 11-18-2019 03:38 8cb60f16 bb_ha325a0c00g0s1200hx.inp 3,784 11-18-2019 00:03 0630a812 bb_ha325a0c00g0s1200hx.out 646,817 11-18-2019 03:37 bb7c4e5b bb_ha325a0c00g0s1300hx.inp 3,784 11-18-2019 00:03 3be005d4 bb_ha325a0c00g0s1300hx.out 646,487 11-18-2019 03:36 80e79339 bb_ha325a0c00g0s1400hx.inp 3,784 11-18-2019 00:03 c887a8d2 bb_ha325a0c00g0s1400hx.out 646,934 11-18-2019 03:37 a3376e5b bb_ha325a0c00g0s1500hx.inp 3,784 11-18-2019 00:03 94557c65 bb_ha325a0c00g0s1500hx.out 646,682 11-18-2019 03:29 94c23714
\\v1.2\\bb\\hs245\\ (22) 7,164,270 11-20-2019 09:22 bb_hs245a0c00g0s0500hx.inp 3,862 11-18-2019 14:20 b72bcb84 bb_hs245a0c00g0s0500hx.out 648,445 11-19-2019 16:33 500fe503 bb_hs245a0c00g0s0600hx.inp 3,863 11-18-2019 14:20 b52f2888 bb_hs245a0c00g0s0600hx.out 646,816 11-19-2019 16:30 91fb8516 bb_hs245a0c00g0s0700hx.inp 3,863 11-18-2019 14:20 ca21738a bb_hs245a0c00g0s0700hx.out 647,613 11-19-2019 16:30 57ed2687 bb_hs245a0c00g0s0800hx.inp 3,863 11-18-2019 14:20 1ba545b9 bb_hs245a0c00g0s0800hx.out 646,890 11-19-2019 16:29 b822e114 bb_hs245a0c00g0s0900hx.inp 3,863 11-18-2019 14:20 159722c9 bb_hs245a0c00g0s0900hx.out 647,616 11-19-2019 16:27 d68dec90 bb_hs245a0c00g0s1000hx.inp 3,867 11-18-2019 14:20 5688e576 bb_hs245a0c00g0s1000hx.out 648,281 11-19-2019 16:26 9e78dd4c bb_hs245a0c00g0s1100hx.inp 3,867 11-18-2019 14:20 4de4eb95 bb_hs245a0c00g0s1100hx.out 647,165 11-19-2019 16:26 33664576 bb_hs245a0c00g0s1200hx.inp 3,867 11-18-2019 14:20 152af347 bb_hs245a0c00g0s1200hx.out 647,481 11-19-2019 16:28 34043ebc bb_hs245a0c00g0s1300hx.inp 3,867 11-18-2019 14:20 0327f50e bb_hs245a0c00g0s1300hx.out 646,758 11-19-2019 16:30 0775e650 bb_hs245a0c00g0s1400hx.inp 3,867 11-18-2019 14:20 ac6bef41 bb_hs245a0c00g0s1400hx.out 646,538 11-19-2019 16:31 70e53f83 bb_hs245a0c00g0s1500hx.inp 3,867 11-18-2019 14:21 ec26d549 bb_hs245a0c00g0s1500hx.out 648,151 11-19-2019 16:35 4aebc9b5
\\v1.2\\bb\\hs325\\ (22) 7,151,873 11-20-2019 09:22 bb_hs325a0c00g0s0500hx.inp 3,813 11-18-2019 12:32 a4cddad4 bb_hs325a0c00g0s0500hx.out 646,478 11-19-2019 11:28 88c0931a bb_hs325a0c00g0s0600hx.inp 3,813 11-18-2019 12:32 c154d7de bb_hs325a0c00g0s0600hx.out 646,699 11-19-2019 11:33 b37219fd bb_hs325a0c00g0s0700hx.inp 3,813 11-18-2019 12:32 5b0a9909 bb_hs325a0c00g0s0700hx.out 646,097 11-19-2019 11:30 e88a52af bb_hs325a0c00g0s0800hx.inp 3,813 11-18-2019 12:32 e0cf40f9 bb_hs325a0c00g0s0800hx.out 645,352 11-19-2019 11:39 46c1577a bb_hs325a0c00g0s0900hx.inp 3,813 11-18-2019 12:32 2dddeb22 bb_hs325a0c00g0s0900hx.out 646,274 11-19-2019 11:40 44656078 bb_hs325a0c00g0s1000hx.inp 3,817 11-18-2019 12:33 f505c5e7 bb_hs325a0c00g0s1000hx.out 646,678 11-19-2019 11:36 b9c6e407 bb_hs325a0c00g0s1100hx.inp 3,817 11-18-2019 12:33 19b08a5c bb_hs325a0c00g0s1100hx.out 646,260 11-19-2019 11:25 bc0aa8a6 bb_hs325a0c00g0s1200hx.inp 3,817 11-18-2019 12:33 aea2504a bb_hs325a0c00g0s1200hx.out 646,428 11-19-2019 11:26 061053a8 bb_hs325a0c00g0s1300hx.inp 3,817 11-18-2019 12:33 b8be9abe bb_hs325a0c00g0s1300hx.out 645,999 11-19-2019 11:43 29a9d541 bb_hs325a0c00g0s1400hx.inp 3,817 11-18-2019 12:33 ab0fbf7f bb_hs325a0c00g0s1400hx.out 646,319 11-19-2019 11:29 24b90d8a bb_hs325a0c00g0s1500hx.inp 3,817 11-18-2019 12:33 b2afc5d8 bb_hs325a0c00g0s1500hx.out 647,322 11-19-2019 11:29 0dc26d55
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
58 of 190
\\v1.2\\bb\\na245\\ (22) 7,166,077 11-20-2019 09:22 bb_na245a0c00g0s0500hx.inp 3,861 11-18-2019 11:09 eb0110dc bb_na245a0c00g0s0500hx.out 646,773 11-19-2019 03:54 e75a7c89 bb_na245a0c00g0s0600hx.inp 3,862 11-18-2019 11:09 cd9a2250 bb_na245a0c00g0s0600hx.out 647,979 11-19-2019 03:47 fa80188f bb_na245a0c00g0s0700hx.inp 3,862 11-18-2019 11:09 07766281 bb_na245a0c00g0s0700hx.out 647,595 11-19-2019 03:48 517208c5 bb_na245a0c00g0s0800hx.inp 3,862 11-18-2019 11:09 e588883a bb_na245a0c00g0s0800hx.out 647,562 11-19-2019 03:59 8f1de742 bb_na245a0c00g0s0900hx.inp 3,862 11-18-2019 11:09 7fea065c bb_na245a0c00g0s0900hx.out 647,824 11-19-2019 03:56 d6435733 bb_na245a0c00g0s1000hx.inp 3,866 11-18-2019 11:09 9abe9084 bb_na245a0c00g0s1000hx.out 647,629 11-19-2019 03:34 d1490496 bb_na245a0c00g0s1100hx.inp 3,866 11-18-2019 11:09 446f4e0a bb_na245a0c00g0s1100hx.out 647,832 11-19-2019 03:58 79c9cae0 bb_na245a0c00g0s1200hx.inp 3,866 11-18-2019 11:09 e2f76714 bb_na245a0c00g0s1200hx.out 647,808 11-19-2019 03:58 2d8772aa bb_na245a0c00g0s1300hx.inp 3,866 11-18-2019 11:09 46a13c1e bb_na245a0c00g0s1300hx.out 647,689 11-19-2019 03:51 a2478610 bb_na245a0c00g0s1400hx.inp 3,866 11-18-2019 11:10 b97ebc01 bb_na245a0c00g0s1400hx.out 647,530 11-19-2019 03:51 d995b601 bb_na245a0c00g0s1500hx.inp 3,866 11-18-2019 11:10 f42e96bf bb_na245a0c00g0s1500hx.out 647,351 11-19-2019 03:33 d06a6af8
\\v1.2\\bb\\na325\\ (22) 7,152,738 11-20-2019 09:22 bb_na325a0c00g0s0500hx.inp 3,812 11-18-2019 10:07 d540df89 bb_na325a0c00g0s0500hx.out 646,764 11-18-2019 19:38 57815b7e bb_na325a0c00g0s0600hx.inp 3,812 11-18-2019 10:07 07650855 bb_na325a0c00g0s0600hx.out 646,637 11-18-2019 19:48 f8092951 bb_na325a0c00g0s0700hx.inp 3,812 11-18-2019 10:07 d11bc49e bb_na325a0c00g0s0700hx.out 646,074 11-18-2019 19:34 0d5bc530 bb_na325a0c00g0s0800hx.inp 3,812 11-18-2019 10:07 d8e9a4b1 bb_na325a0c00g0s0800hx.out 645,728 11-18-2019 19:34 1c00fe47 bb_na325a0c00g0s0900hx.inp 3,812 11-18-2019 10:07 4d0ee89e bb_na325a0c00g0s0900hx.out 646,920 11-18-2019 19:33 44aef3db bb_na325a0c00g0s1000hx.inp 3,816 11-18-2019 10:08 c414eceb bb_na325a0c00g0s1000hx.out 646,213 11-18-2019 19:37 307795dd bb_na325a0c00g0s1100hx.inp 3,816 11-18-2019 10:08 5cbf8544 bb_na325a0c00g0s1100hx.out 646,210 11-18-2019 19:36 9c81f0db bb_na325a0c00g0s1200hx.inp 3,816 11-18-2019 10:08 6cdb7a78 bb_na325a0c00g0s1200hx.out 645,481 11-18-2019 19:39 823ff3e8 bb_na325a0c00g0s1300hx.inp 3,816 11-18-2019 10:08 cda0e3de bb_na325a0c00g0s1300hx.out 646,860 11-18-2019 19:40 c9576197 bb_na325a0c00g0s1400hx.inp 3,816 11-18-2019 10:08 428f7fd4 bb_na325a0c00g0s1400hx.out 646,259 11-18-2019 19:44 61d7306b bb_na325a0c00g0s1500hx.inp 3,816 11-18-2019 10:08 6a78b962 bb_na325a0c00g0s1500hx.out 647,636 11-18-2019 19:53 8f8e2a58
\\v1.2\\bb\\ns245\\ (22) 7,166,523 11-20-2019 09:22 bb_ns245a0c00g0s0500hx.inp 3,862 11-18-2019 16:51 6b782bb6 bb_ns245a0c00g0s0500hx.out 647,499 11-20-2019 03:08 2d7f37f3 bb_ns245a0c00g0s0600hx.inp 3,863 11-18-2019 16:51 4fcd2747 bb_ns245a0c00g0s0600hx.out 647,750 11-20-2019 03:08 b4e6babd bb_ns245a0c00g0s0700hx.inp 3,863 11-18-2019 16:51 30c37c45 bb_ns245a0c00g0s0700hx.out 647,138 11-20-2019 03:18 f1a4f60d bb_ns245a0c00g0s0800hx.inp 3,863 11-18-2019 16:51 e1474a76 bb_ns245a0c00g0s0800hx.out 648,761 11-20-2019 03:04 dbc2dfaa bb_ns245a0c00g0s0900hx.inp 3,863 11-18-2019 16:52 ef752d06 bb_ns245a0c00g0s0900hx.out 647,919 11-20-2019 03:04 23d5bb7d bb_ns245a0c00g0s1000hx.inp 3,867 11-18-2019 16:52 7646e955 bb_ns245a0c00g0s1000hx.out 647,278 11-20-2019 02:59 e532540e bb_ns245a0c00g0s1100hx.inp 3,867 11-18-2019 16:52 6d2ae7b6 bb_ns245a0c00g0s1100hx.out 647,981 11-20-2019 03:06 2b3846c3 bb_ns245a0c00g0s1200hx.inp 3,867 11-18-2019 16:52 35e4ff64 bb_ns245a0c00g0s1200hx.out 647,410 11-20-2019 03:05 738261d0 bb_ns245a0c00g0s1300hx.inp 3,867 11-18-2019 16:52 23e9f92d bb_ns245a0c00g0s1300hx.out 647,643 11-20-2019 03:06 54660df5 bb_ns245a0c00g0s1400hx.inp 3,867 11-18-2019 16:52 8ca5e362 bb_ns245a0c00g0s1400hx.out 647,247 11-20-2019 03:04 87224f6b bb_ns245a0c00g0s1500hx.inp 3,867 11-18-2019 16:52 cce8d96a bb_ns245a0c00g0s1500hx.out 647,381 11-20-2019 03:08 ba064cd0
\\v1.2\\bb\\ns325\\ (22) 7,155,941 11-20-2019 09:22 bb_ns325a0c00g0s0500hx.inp 3,813 11-18-2019 15:47 c2c92962 bb_ns325a0c00g0s0500hx.out 646,488 11-19-2019 21:55 cf43253b bb_ns325a0c00g0s0600hx.inp 3,813 11-18-2019 15:47 a7502468 bb_ns325a0c00g0s0600hx.out 646,512 11-19-2019 21:55 a0588113
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
59 of 190 bb_ns325a0c00g0s0700hx.inp 3,813 11-18-2019 15:47 3d0e6abf bb_ns325a0c00g0s0700hx.out 646,538 11-19-2019 21:57 f6e003a3 bb_ns325a0c00g0s0800hx.inp 3,813 11-18-2019 15:47 86cbb34f bb_ns325a0c00g0s0800hx.out 646,766 11-19-2019 21:50 3323f73d bb_ns325a0c00g0s0900hx.inp 3,813 11-18-2019 15:47 4bd91894 bb_ns325a0c00g0s0900hx.out 647,137 11-19-2019 21:55 b420c07e bb_ns325a0c00g0s1000hx.inp 3,817 11-18-2019 15:47 94d8e42f bb_ns325a0c00g0s1000hx.out 646,489 11-19-2019 21:50 bb8fc4fe bb_ns325a0c00g0s1100hx.inp 3,817 11-18-2019 15:47 786dab94 bb_ns325a0c00g0s1100hx.out 646,301 11-19-2019 21:59 1a7527d3 bb_ns325a0c00g0s1200hx.inp 3,817 11-18-2019 15:48 cf7f7182 bb_ns325a0c00g0s1200hx.out 646,788 11-19-2019 21:51 6eb01161 bb_ns325a0c00g0s1300hx.inp 3,817 11-18-2019 15:48 d963bb76 bb_ns325a0c00g0s1300hx.out 646,470 11-19-2019 22:06 358f9855 bb_ns325a0c00g0s1400hx.inp 3,817 11-18-2019 15:48 cad29eb7 bb_ns325a0c00g0s1400hx.out 647,431 11-19-2019 22:10 8bc38542 bb_ns325a0c00g0s1500hx.inp 3,817 11-18-2019 15:48 d372e410 bb_ns325a0c00g0s1500hx.out 647,054 11-19-2019 21:57 378c257c
\\v1.2\\bc\\ (0) 50,848,174 11-18-2019 16:52
\\v1.2\\bc\\ha245\\ (22) 7,163,336 11-18-2019 20:33 bc_ha245a0c00g0s0500hx.inp 3,838 11-18-2019 01:56 ad070699 bc_ha245a0c00g0s0500hx.out 647,492 11-18-2019 13:37 7fec2c7e bc_ha245a0c00g0s0600hx.inp 3,839 11-18-2019 01:56 8703c3b2 bc_ha245a0c00g0s0600hx.out 647,996 11-18-2019 13:33 63af9fd4 bc_ha245a0c00g0s0700hx.inp 3,839 11-18-2019 01:56 2c8f38d6 bc_ha245a0c00g0s0700hx.out 647,433 11-18-2019 13:30 a518c645 bc_ha245a0c00g0s0800hx.inp 3,839 11-18-2019 01:56 8e9459c5 bc_ha245a0c00g0s0800hx.out 647,479 11-18-2019 13:28 c64f993a bc_ha245a0c00g0s0900hx.inp 3,839 11-18-2019 01:56 06147ff4 bc_ha245a0c00g0s0900hx.out 647,528 11-18-2019 13:26 85ca1f5d bc_ha245a0c00g0s1000hx.inp 3,843 11-18-2019 01:57 3e187fe5 bc_ha245a0c00g0s1000hx.out 646,708 11-18-2019 13:26 1c4ccd1b bc_ha245a0c00g0s1100hx.inp 3,843 11-18-2019 01:57 16feffa5 bc_ha245a0c00g0s1100hx.out 647,624 11-18-2019 13:28 245ef9ab bc_ha245a0c00g0s1200hx.inp 3,843 11-18-2019 01:57 9da52d6f bc_ha245a0c00g0s1200hx.out 647,558 11-18-2019 13:28 cffa6794 bc_ha245a0c00g0s1300hx.inp 3,843 11-18-2019 01:57 aa23c231 bc_ha245a0c00g0s1300hx.out 647,139 11-18-2019 13:30 134d0d49 bc_ha245a0c00g0s1400hx.inp 3,843 11-18-2019 01:57 14e4f09d bc_ha245a0c00g0s1400hx.out 646,800 11-18-2019 13:29 bcf4e3b5 bc_ha245a0c00g0s1500hx.inp 3,843 11-18-2019 01:57 b73a3369 bc_ha245a0c00g0s1500hx.out 647,327 11-18-2019 13:32 013701cd
\\v1.2\\bc\\ha325\\ (22) 7,153,075 11-18-2019 20:33 bc_ha325a0c00g0s0500hx.inp 3,784 11-18-2019 00:03 11e79a6d bc_ha325a0c00g0s0500hx.out 646,054 11-18-2019 03:42 0494f3cb bc_ha325a0c00g0s0600hx.inp 3,784 11-18-2019 00:03 7c53e9fd bc_ha325a0c00g0s0600hx.out 646,885 11-18-2019 03:42 dc65ff11 bc_ha325a0c00g0s0700hx.inp 3,784 11-18-2019 00:04 564fafe4 bc_ha325a0c00g0s0700hx.out 646,601 11-18-2019 03:41 0351e12c bc_ha325a0c00g0s0800hx.inp 3,784 11-18-2019 00:04 c9d92f4e bc_ha325a0c00g0s0800hx.out 646,415 11-18-2019 03:39 4e55da19 bc_ha325a0c00g0s0900hx.inp 3,784 11-18-2019 00:04 653c8f60 bc_ha325a0c00g0s0900hx.out 645,793 11-18-2019 03:39 d8e91382 bc_ha325a0c00g0s1000hx.inp 3,788 11-18-2019 00:04 df716766 bc_ha325a0c00g0s1000hx.out 646,945 11-18-2019 03:40 a8d97b7a bc_ha325a0c00g0s1100hx.inp 3,788 11-18-2019 00:04 91adc46f bc_ha325a0c00g0s1100hx.out 646,076 11-18-2019 03:35 4005abf3 bc_ha325a0c00g0s1200hx.inp 3,788 11-18-2019 00:04 d9b136c6 bc_ha325a0c00g0s1200hx.out 646,394 11-18-2019 03:36 4cd98df8 bc_ha325a0c00g0s1300hx.inp 3,788 11-18-2019 00:04 7e48f8dd bc_ha325a0c00g0s1300hx.out 645,682 11-18-2019 03:43 6cd1f44e bc_ha325a0c00g0s1400hx.inp 3,788 11-18-2019 00:04 53847160 bc_ha325a0c00g0s1400hx.out 647,237 11-18-2019 03:39 6813af32 bc_ha325a0c00g0s1500hx.inp 3,788 11-18-2019 00:04 6bbc06c6 bc_ha325a0c00g0s1500hx.out 647,345 11-18-2019 03:27 68a0a55a
\\v1.2\\bc\\hs245\\ (22) 5,557,894 11-20-2019 09:22 bc_hs245a0c00g0s0500hx.inp 3,866 11-18-2019 14:21 d69574a4 bc_hs245a0c00g0s0500hx.out 501,222 11-19-2019 16:39 ebd4f6b8 bc_hs245a0c00g0s0600hx.inp 3,867 11-18-2019 14:21 a4157dcd bc_hs245a0c00g0s0600hx.out 500,817 11-19-2019 16:34 137242dd bc_hs245a0c00g0s0700hx.inp 3,867 11-18-2019 14:21 4e52bb4b bc_hs245a0c00g0s0700hx.out 500,979 11-19-2019 16:33 5351ecd4 bc_hs245a0c00g0s0800hx.inp 3,867 11-18-2019 14:21 578cb0e8
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
60 of 190 bc_hs245a0c00g0s0800hx.out 501,421 11-19-2019 16:48 e9650f32 bc_hs245a0c00g0s0900hx.inp 3,867 11-18-2019 14:21 bc6a01e1 bc_hs245a0c00g0s0900hx.out 501,061 11-19-2019 16:39 40cffb8c bc_hs245a0c00g0s1000hx.inp 3,871 11-18-2019 14:21 23a81452 bc_hs245a0c00g0s1000hx.out 501,106 11-19-2019 16:33 c0a519a3 bc_hs245a0c00g0s1100hx.inp 3,871 11-18-2019 14:21 67c7c398 bc_hs245a0c00g0s1100hx.out 501,383 11-19-2019 17:01 a12b42ee bc_hs245a0c00g0s1200hx.inp 3,871 11-18-2019 14:21 be0b35b8 bc_hs245a0c00g0s1200hx.out 502,091 11-19-2019 17:05 a8b94d84 bc_hs245a0c00g0s1300hx.inp 3,871 11-18-2019 14:21 0a9e155a bc_hs245a0c00g0s1300hx.out 501,536 11-19-2019 17:07 f64293c9 bc_hs245a0c00g0s1400hx.inp 3,871 11-18-2019 14:21 2a3f1ca1 bc_hs245a0c00g0s1400hx.out 502,178 11-19-2019 17:14 cbc66f25 bc_hs245a0c00g0s1500hx.inp 3,871 11-18-2019 14:21 0ac16ea2 bc_hs245a0c00g0s1500hx.out 501,540 11-19-2019 17:17 dc06cb87
\\v1.2\\bc\\hs325\\ (22) 5,545,948 11-20-2019 09:22 bc_hs325a0c00g0s0500hx.inp 3,817 11-18-2019 12:33 fbbc6a89 bc_hs325a0c00g0s0500hx.out 499,948 11-19-2019 11:21 3c50e1a7 bc_hs325a0c00g0s0600hx.inp 3,817 11-18-2019 12:33 cdcd3ea4 bc_hs325a0c00g0s0600hx.out 500,906 11-19-2019 11:30 6d18ff7e bc_hs325a0c00g0s0700hx.inp 3,817 11-18-2019 12:33 edcb286a bc_hs325a0c00g0s0700hx.out 500,205 11-19-2019 11:43 ad8c356c bc_hs325a0c00g0s0800hx.inp 3,817 11-18-2019 12:33 184edb9b bc_hs325a0c00g0s0800hx.out 500,923 11-19-2019 11:44 a8bfe81e bc_hs325a0c00g0s0900hx.inp 3,817 11-18-2019 12:33 eb2948b9 bc_hs325a0c00g0s0900hx.out 500,636 11-19-2019 11:46 b5fb84ac bc_hs325a0c00g0s1000hx.inp 3,821 11-18-2019 12:34 a94bae78 bc_hs325a0c00g0s1000hx.out 500,416 11-19-2019 11:29 22e760ea bc_hs325a0c00g0s1100hx.inp 3,821 11-18-2019 12:34 8e39a21b bc_hs325a0c00g0s1100hx.out 500,089 11-19-2019 11:31 092edfa1 bc_hs325a0c00g0s1200hx.inp 3,821 11-18-2019 12:34 677d9c86 bc_hs325a0c00g0s1200hx.out 500,196 11-19-2019 11:27 925f950e bc_hs325a0c00g0s1300hx.inp 3,821 11-18-2019 12:34 59ca33a6 bc_hs325a0c00g0s1300hx.out 500,155 11-19-2019 11:42 4d4ab48f bc_hs325a0c00g0s1400hx.inp 3,821 11-18-2019 12:34 29340b2a bc_hs325a0c00g0s1400hx.out 499,991 11-19-2019 11:35 47ddc37e bc_hs325a0c00g0s1500hx.inp 3,821 11-18-2019 12:34 20331d53 bc_hs325a0c00g0s1500hx.out 500,472 11-19-2019 11:46 dc8cf314
\\v1.2\\bc\\na245\\ (22) 7,167,676 11-20-2019 09:22 bc_na245a0c00g0s0500hx.inp 3,865 11-18-2019 11:10 7a7e6710 bc_na245a0c00g0s0500hx.out 647,893 11-19-2019 03:53 ec4d48a0 bc_na245a0c00g0s0600hx.inp 3,866 11-18-2019 11:10 e6da5a3a bc_na245a0c00g0s0600hx.out 647,540 11-19-2019 04:00 9c86d19c bc_na245a0c00g0s0700hx.inp 3,866 11-18-2019 11:10 23752bc8 bc_na245a0c00g0s0700hx.out 647,418 11-19-2019 03:50 4b849eb7 bc_na245a0c00g0s0800hx.inp 3,866 11-18-2019 11:10 d94f9170 bc_na245a0c00g0s0800hx.out 647,834 11-19-2019 03:50 5bd1e3d3 bc_na245a0c00g0s0900hx.inp 3,866 11-18-2019 11:10 76901453 bc_na245a0c00g0s0900hx.out 648,127 11-19-2019 03:47 17afb4b3 bc_na245a0c00g0s1000hx.inp 3,870 11-18-2019 11:10 c9453742 bc_na245a0c00g0s1000hx.out 648,452 11-19-2019 03:44 44f9cc54 bc_na245a0c00g0s1100hx.inp 3,870 11-18-2019 11:10 dd5d0a46 bc_na245a0c00g0s1100hx.out 648,132 11-19-2019 03:46 4ef6ac10 bc_na245a0c00g0s1200hx.inp 3,870 11-18-2019 11:10 e62b7c57 bc_na245a0c00g0s1200hx.out 647,172 11-19-2019 03:48 a22ce388 bc_na245a0c00g0s1300hx.inp 3,870 11-18-2019 11:10 ced56c69 bc_na245a0c00g0s1300hx.out 647,401 11-19-2019 03:58 f2a19ca9 bc_na245a0c00g0s1400hx.inp 3,870 11-18-2019 11:11 55146c4c bc_na245a0c00g0s1400hx.out 647,840 11-19-2019 04:08 2aed7ebc bc_na245a0c00g0s1500hx.inp 3,870 11-18-2019 11:11 a4b5baed bc_na245a0c00g0s1500hx.out 647,318 11-19-2019 04:15 3480c4a7
\\v1.2\\bc\\na325\\ (22) 7,155,739 11-20-2019 09:22 bc_na325a0c00g0s0500hx.inp 3,816 11-18-2019 10:08 339d2f10 bc_na325a0c00g0s0500hx.out 646,892 11-18-2019 19:41 261d764b bc_na325a0c00g0s0600hx.inp 3,816 11-18-2019 10:08 cc84d0da bc_na325a0c00g0s0600hx.out 646,935 11-18-2019 19:38 e77267e9 bc_na325a0c00g0s0700hx.inp 3,816 11-18-2019 10:08 b97215ff bc_na325a0c00g0s0700hx.out 646,847 11-18-2019 19:44 a77c71eb bc_na325a0c00g0s0800hx.inp 3,816 11-18-2019 10:08 665ed707 bc_na325a0c00g0s0800hx.out 646,675 11-18-2019 19:38 fee46a76 bc_na325a0c00g0s0900hx.inp 3,816 11-18-2019 10:08 a408b1fe bc_na325a0c00g0s0900hx.out 646,637 11-18-2019 19:49 1892328a bc_na325a0c00g0s1000hx.inp 3,820 11-18-2019 10:08 08c6ade3 bc_na325a0c00g0s1000hx.out 646,993 11-18-2019 19:47 7adae90e bc_na325a0c00g0s1100hx.inp 3,820 11-18-2019 10:09 8e73c234
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
61 of 190 bc_na325a0c00g0s1100hx.out 646,912 11-18-2019 19:47 0d7a9612 bc_na325a0c00g0s1200hx.inp 3,820 11-18-2019 10:09 841bde88 bc_na325a0c00g0s1200hx.out 646,092 11-18-2019 19:40 0612e0d9 bc_na325a0c00g0s1300hx.inp 3,820 11-18-2019 10:09 8fec1091 bc_na325a0c00g0s1300hx.out 646,792 11-18-2019 19:41 6dd8efb5 bc_na325a0c00g0s1400hx.inp 3,820 11-18-2019 10:09 ac4c5129 bc_na325a0c00g0s1400hx.out 646,492 11-18-2019 19:53 ef6a3d47 bc_na325a0c00g0s1500hx.inp 3,820 11-18-2019 10:09 8cf15336 bc_na325a0c00g0s1500hx.out 646,472 11-18-2019 19:55 95a85bee
\\v1.2\\bc\\ns245\\ (22) 5,559,499 11-20-2019 09:22 bc_ns245a0c00g0s0500hx.inp 3,866 11-18-2019 16:52 a6668e11 bc_ns245a0c00g0s0500hx.out 502,138 11-20-2019 03:10 60b0a33f bc_ns245a0c00g0s0600hx.inp 3,867 11-18-2019 16:52 2d87c49b bc_ns245a0c00g0s0600hx.out 501,218 11-20-2019 03:08 5a847b8f bc_ns245a0c00g0s0700hx.inp 3,867 11-18-2019 16:52 c7c0021d bc_ns245a0c00g0s0700hx.out 502,377 11-20-2019 03:23 ca7353f7 bc_ns245a0c00g0s0800hx.inp 3,867 11-18-2019 16:52 de1e09be bc_ns245a0c00g0s0800hx.out 501,041 11-20-2019 03:04 d2cb313a bc_ns245a0c00g0s0900hx.inp 3,867 11-18-2019 16:53 35f8b8b7 bc_ns245a0c00g0s0900hx.out 502,144 11-20-2019 03:14 b94a5a79 bc_ns245a0c00g0s1000hx.inp 3,871 11-18-2019 16:53 6be2bdb9 bc_ns245a0c00g0s1000hx.out 501,679 11-20-2019 03:24 f8503ad2 bc_ns245a0c00g0s1100hx.inp 3,871 11-18-2019 16:53 2f8d6a73 bc_ns245a0c00g0s1100hx.out 501,409 11-20-2019 03:10 b4a7ee00 bc_ns245a0c00g0s1200hx.inp 3,871 11-18-2019 16:53 f6419c53 bc_ns245a0c00g0s1200hx.out 501,145 11-20-2019 03:20 d9458393 bc_ns245a0c00g0s1300hx.inp 3,871 11-18-2019 16:53 42d4bcb1 bc_ns245a0c00g0s1300hx.out 500,530 11-20-2019 03:13 9be40ae1 bc_ns245a0c00g0s1400hx.inp 3,871 11-18-2019 16:53 6275b54a bc_ns245a0c00g0s1400hx.out 501,028 11-20-2019 03:08 09202ae3 bc_ns245a0c00g0s1500hx.inp 3,871 11-18-2019 16:53 428bc749 bc_ns245a0c00g0s1500hx.out 502,230 11-20-2019 03:25 d9351721
\\v1.2\\bc\\ns325\\ (22) 5,545,007 11-20-2019 09:22 bc_ns325a0c00g0s0500hx.inp 3,817 11-18-2019 15:48 295a3d78 bc_ns325a0c00g0s0500hx.out 500,330 11-19-2019 22:02 b9b027fe bc_ns325a0c00g0s0600hx.inp 3,817 11-18-2019 15:48 1f2b6955 bc_ns325a0c00g0s0600hx.out 500,095 11-19-2019 21:46 e9b5ce21 bc_ns325a0c00g0s0700hx.inp 3,817 11-18-2019 15:48 3f2d7f9b bc_ns325a0c00g0s0700hx.out 500,132 11-19-2019 21:52 52b5744b bc_ns325a0c00g0s0800hx.inp 3,817 11-18-2019 15:48 caa88c6a bc_ns325a0c00g0s0800hx.out 500,375 11-19-2019 21:56 fa5ed303 bc_ns325a0c00g0s0900hx.inp 3,817 11-18-2019 15:48 39cf1f48 bc_ns325a0c00g0s0900hx.out 500,694 11-19-2019 22:09 ba23c57d bc_ns325a0c00g0s1000hx.inp 3,821 11-18-2019 15:48 b0de248d bc_ns325a0c00g0s1000hx.out 500,587 11-19-2019 22:07 9ac6c74f bc_ns325a0c00g0s1100hx.inp 3,821 11-18-2019 15:48 97ac28ee bc_ns325a0c00g0s1100hx.out 499,358 11-19-2019 21:56 18ca3388 bc_ns325a0c00g0s1200hx.inp 3,821 11-18-2019 15:49 7ee81673 bc_ns325a0c00g0s1200hx.out 499,799 11-19-2019 21:58 2d973553 bc_ns325a0c00g0s1300hx.inp 3,821 11-18-2019 15:49 405fb953 bc_ns325a0c00g0s1300hx.out 500,427 11-19-2019 22:14 9660be2c bc_ns325a0c00g0s1400hx.inp 3,821 11-18-2019 15:49 30a181df bc_ns325a0c00g0s1400hx.out 500,261 11-19-2019 21:53 b93a90af bc_ns325a0c00g0s1500hx.inp 3,821 11-18-2019 15:49 39a697a6 bc_ns325a0c00g0s1500hx.out 500,938 11-19-2019 22:21 7e874088
\\v1.2\\bd\\ (0) 46,868,032 11-18-2019 16:53
\\v1.2\\bd\\ha245\\ (18) 5,862,323 11-22-2019 12:48 bd_ha245a0c00g0s001vfio.inp 3,835 11-18-2019 01:57 4969d30e bd_ha245a0c00g0s001vfio.out 647,962 11-18-2019 11:46 19b75486 bd_ha245a0c00g0s005vfio.inp 3,835 11-18-2019 01:57 7bdec582 bd_ha245a0c00g0s005vfio.out 647,887 11-18-2019 11:53 067d25f8 bd_ha245a0c00g0s010vfio.inp 3,835 11-18-2019 01:57 3f683ac6 bd_ha245a0c00g0s010vfio.out 647,265 11-18-2019 12:16 7e2d599f bd_ha245a0c00g0s030vfio.inp 3,835 11-18-2019 01:57 d5410dac bd_ha245a0c00g0s030vfio.out 647,641 11-18-2019 12:50 b5f9fee7 bd_ha245a0c00g0s050vfio.inp 3,835 11-18-2019 01:57 039fc7ab bd_ha245a0c00g0s050vfio.out 647,277 11-18-2019 13:05 2043de68 bd_ha245a0c00g0s070vfio.inp 3,835 11-18-2019 01:57 93cd1bec bd_ha245a0c00g0s070vfio.out 647,713 11-18-2019 13:16 09e93a92 bd_ha245a0c00g0s090vfio.inp 3,835 11-18-2019 01:58 77af59fe bd_ha245a0c00g0s090vfio.out 647,325 11-18-2019 13:21 8105ae3f bd_ha245a0c00g0s095vfio.inp 3,835 11-18-2019 01:58 c462b834 bd_ha245a0c00g0s095vfio.out 647,490 11-18-2019 13:24 0f0bbcc0
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
62 of 190 bd_ha245a0c00g0s100vfio.inp 3,835 11-18-2019 01:58 0be8b43c bd_ha245a0c00g0s100vfio.out 647,248 11-18-2019 13:22 95cf942a
\\v1.2\\bd\\ha325\\ (18) 5,853,267 11-22-2019 12:48 bd_ha325a0c00g0s001vfio.inp 3,780 11-18-2019 00:04 56736081 bd_ha325a0c00g0s001vfio.out 646,793 11-18-2019 02:00 b78f6ffd bd_ha325a0c00g0s005vfio.inp 3,780 11-18-2019 00:04 1e6b96b6 bd_ha325a0c00g0s005vfio.out 646,401 11-18-2019 02:00 6f1ed7a2 bd_ha325a0c00g0s010vfio.inp 3,780 11-18-2019 00:04 ad11c229 bd_ha325a0c00g0s010vfio.out 646,459 11-18-2019 02:21 9ae9d8a6 bd_ha325a0c00g0s030vfio.inp 3,780 11-18-2019 00:05 4cbd8cad bd_ha325a0c00g0s030vfio.out 647,529 11-18-2019 03:02 55c12ddf bd_ha325a0c00g0s050vfio.inp 3,780 11-18-2019 00:05 016f7f6d bd_ha325a0c00g0s050vfio.out 646,339 11-18-2019 03:25 4e72c017 bd_ha325a0c00g0s070vfio.inp 3,780 11-18-2019 00:05 1d5fc40e bd_ha325a0c00g0s070vfio.out 646,090 11-18-2019 03:37 0655849a bd_ha325a0c00g0s090vfio.inp 3,780 11-18-2019 00:05 597f01ea bd_ha325a0c00g0s090vfio.out 645,612 11-18-2019 03:39 89c29ce8 bd_ha325a0c00g0s095vfio.inp 3,780 11-18-2019 00:05 5bfdb933 bd_ha325a0c00g0s095vfio.out 646,841 11-18-2019 03:41 e9a37fb0 bd_ha325a0c00g0s100vfio.inp 3,780 11-18-2019 00:05 adae9e9e bd_ha325a0c00g0s100vfio.out 647,183 11-18-2019 03:36 e816c5d0
\\v1.2\\bd\\hs245\\ (18) 5,862,010 11-22-2019 12:48 bd_hs245a0c00g0s001vfi.inp 3,863 11-18-2019 14:22 dfb01826 bd_hs245a0c00g0s001vfi.out 647,335 11-19-2019 16:31 80c61549 bd_hs245a0c00g0s005vfi.inp 3,863 11-18-2019 14:22 a176718d bd_hs245a0c00g0s005vfi.out 647,692 11-19-2019 16:19 87daa725 bd_hs245a0c00g0s010vfi.inp 3,863 11-18-2019 14:22 5266aa78 bd_hs245a0c00g0s010vfi.out 647,783 11-19-2019 16:31 1a24e589 bd_hs245a0c00g0s030vfi.inp 3,863 11-18-2019 14:22 f29bf803 bd_hs245a0c00g0s030vfi.out 647,255 11-19-2019 16:43 54e3cdac bd_hs245a0c00g0s050vfi.inp 3,863 11-18-2019 14:22 28dffc00 bd_hs245a0c00g0s050vfi.out 647,237 11-19-2019 16:54 d925e879 bd_hs245a0c00g0s070vfi.inp 3,863 11-18-2019 14:22 6c7f6652 bd_hs245a0c00g0s070vfi.out 647,371 11-19-2019 17:18 751c3b26 bd_hs245a0c00g0s090vfi.inp 3,863 11-18-2019 14:22 be78e9e0 bd_hs245a0c00g0s090vfi.out 647,765 11-19-2019 16:54 ebbfd37b bd_hs245a0c00g0s095vfi.inp 3,863 11-18-2019 14:22 3609b355 bd_hs245a0c00g0s095vfi.out 647,191 11-19-2019 17:05 13994f9c bd_hs245a0c00g0s100vfi.inp 3,863 11-18-2019 14:22 159722c9 bd_hs245a0c00g0s100vfi.out 647,614 11-19-2019 17:09 fbb4961d
\\v1.2\\bd\\hs325\\ (18) 5,852,410 11-22-2019 12:48 bd_hs325a0c00g0s001vfi.inp 3,813 11-18-2019 12:34 1927f4db bd_hs325a0c00g0s001vfi.out 646,292 11-19-2019 10:57 21b44d9d bd_hs325a0c00g0s005vfi.inp 3,813 11-18-2019 12:34 5aa8e62b bd_hs325a0c00g0s005vfi.out 646,626 11-19-2019 10:50 df3a0aa8 bd_hs325a0c00g0s010vfi.inp 3,813 11-18-2019 12:34 8db58e7f bd_hs325a0c00g0s010vfi.out 647,005 11-19-2019 10:53 b26c9c37 bd_hs325a0c00g0s030vfi.inp 3,813 11-18-2019 12:34 6c544712 bd_hs325a0c00g0s030vfi.out 646,466 11-19-2019 11:04 49b1955f bd_hs325a0c00g0s050vfi.inp 3,813 11-18-2019 12:34 116fa5ab bd_hs325a0c00g0s050vfi.out 646,032 11-19-2019 11:24 f2a02e2c bd_hs325a0c00g0s070vfi.inp 3,813 11-18-2019 12:35 e8f5031a bd_hs325a0c00g0s070vfi.out 646,989 11-19-2019 11:35 8f5d5781 bd_hs325a0c00g0s090vfi.inp 3,813 11-18-2019 12:35 25aefa8f bd_hs325a0c00g0s090vfi.out 646,758 11-19-2019 11:45 60d25985 bd_hs325a0c00g0s095vfi.inp 3,813 11-18-2019 12:35 fb5d36d2 bd_hs325a0c00g0s095vfi.out 645,648 11-19-2019 11:42 f6d0d46e bd_hs325a0c00g0s100vfi.inp 3,813 11-18-2019 12:35 2dddeb22 bd_hs325a0c00g0s100vfi.out 646,277 11-19-2019 11:44 2c9d04a7
\\v1.2\\bd\\na245\\ (18) 5,866,947 11-22-2019 12:48 bd_na245a0c00g0s001vfio.inp 3,862 11-18-2019 11:11 35ddf6f6 bd_na245a0c00g0s001vfio.out 647,832 11-19-2019 02:31 fe5a90d7 bd_na245a0c00g0s005vfio.inp 3,862 11-18-2019 11:11 af9fe834 bd_na245a0c00g0s005vfio.out 648,425 11-19-2019 02:41 d02d3f08 bd_na245a0c00g0s010vfio.inp 3,862 11-18-2019 11:11 89f3fb9a bd_na245a0c00g0s010vfio.out 648,955 11-19-2019 03:05 c22df69e bd_na245a0c00g0s030vfio.inp 3,862 11-18-2019 11:11 47ed2973 bd_na245a0c00g0s030vfio.out 647,779 11-19-2019 03:57 b24449e9 bd_na245a0c00g0s050vfio.inp 3,862 11-18-2019 11:11 1b276b15 bd_na245a0c00g0s050vfio.out 647,434 11-19-2019 04:12 ce30134e bd_na245a0c00g0s070vfio.inp 3,862 11-18-2019 11:11 33a6d57a bd_na245a0c00g0s070vfio.out 648,571 11-19-2019 04:07 b5bb0167 bd_na245a0c00g0s090vfio.inp 3,862 11-18-2019 11:11 0b4e0f27
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
63 of 190 bd_na245a0c00g0s090vfio.out 647,284 11-19-2019 04:19 fc0c5b67 bd_na245a0c00g0s095vfio.inp 3,862 11-18-2019 11:11 29d3ff85 bd_na245a0c00g0s095vfio.out 648,086 11-19-2019 04:15 8b80c112 bd_na245a0c00g0s100vfio.inp 3,862 11-18-2019 11:12 7fea065c bd_na245a0c00g0s100vfio.out 647,823 11-19-2019 04:24 4a1b313d
\\v1.2\\bd\\na325\\ (18) 5,855,405 11-22-2019 12:48 bd_na325a0c00g0s001vfio.inp 3,812 11-18-2019 10:09 ed472365 bd_na325a0c00g0s001vfio.out 647,320 11-18-2019 18:04 9218771a bd_na325a0c00g0s005vfio.inp 3,812 11-18-2019 10:09 1e3094bc bd_na325a0c00g0s005vfio.out 646,887 11-18-2019 18:10 954466a1 bd_na325a0c00g0s010vfio.inp 3,812 11-18-2019 10:09 b97be980 bd_na325a0c00g0s010vfio.out 646,059 11-18-2019 18:37 4a245df7 bd_na325a0c00g0s030vfio.inp 3,812 11-18-2019 10:09 7267bec1 bd_na325a0c00g0s030vfio.out 647,178 11-18-2019 19:38 f70a6872 bd_na325a0c00g0s050vfio.inp 3,812 11-18-2019 10:09 85f5f932 bd_na325a0c00g0s050vfio.out 646,839 11-18-2019 19:37 3743d47e bd_na325a0c00g0s070vfio.inp 3,812 11-18-2019 10:09 8fb661d9 bd_na325a0c00g0s070vfio.out 646,437 11-18-2019 19:33 e946ff80 bd_na325a0c00g0s090vfio.inp 3,812 11-18-2019 10:09 a3a2352e bd_na325a0c00g0s090vfio.out 646,346 11-18-2019 19:36 0c624326 bd_na325a0c00g0s095vfio.inp 3,812 11-18-2019 10:10 0436ea40 bd_na325a0c00g0s095vfio.out 647,112 11-18-2019 19:47 5c302f60 bd_na325a0c00g0s100vfio.inp 3,812 11-18-2019 10:10 4d0ee89e bd_na325a0c00g0s100vfio.out 646,919 11-18-2019 20:05 f0944a77
\\v1.2\\bd\\ns245\\ (18) 5,860,928 11-22-2019 12:48 bd_ns245a0c00g0s001vfi.inp 3,863 11-18-2019 16:53 255217e9 bd_ns245a0c00g0s001vfi.out 647,196 11-20-2019 02:41 3b0416b5 bd_ns245a0c00g0s005vfi.inp 3,863 11-18-2019 16:53 5b947e42 bd_ns245a0c00g0s005vfi.out 647,607 11-20-2019 02:29 c89d0f54 bd_ns245a0c00g0s010vfi.inp 3,863 11-18-2019 16:53 a884a5b7 bd_ns245a0c00g0s010vfi.out 647,291 11-20-2019 02:30 a1cb9b8c bd_ns245a0c00g0s030vfi.inp 3,863 11-18-2019 16:53 0879f7cc bd_ns245a0c00g0s030vfi.out 646,665 11-20-2019 03:13 a473fcc9 bd_ns245a0c00g0s050vfi.inp 3,863 11-18-2019 16:54 d23df3cf bd_ns245a0c00g0s050vfi.out 646,732 11-20-2019 03:20 5fec8745 bd_ns245a0c00g0s070vfi.inp 3,863 11-18-2019 16:54 969d699d bd_ns245a0c00g0s070vfi.out 647,711 11-20-2019 03:09 7ddf7414 bd_ns245a0c00g0s090vfi.inp 3,863 11-18-2019 16:54 449ae62f bd_ns245a0c00g0s090vfi.out 646,843 11-20-2019 03:18 387713a9 bd_ns245a0c00g0s095vfi.inp 3,863 11-18-2019 16:54 ccebbc9a bd_ns245a0c00g0s095vfi.out 648,196 11-20-2019 03:18 61cc3dc8 bd_ns245a0c00g0s100vfi.inp 3,863 11-18-2019 16:54 ef752d06 bd_ns245a0c00g0s100vfi.out 647,920 11-20-2019 03:25 b2ce20bd
\\v1.2\\bd\\ns325\\ (18) 5,854,742 11-22-2019 12:48 bd_ns325a0c00g0s001vfi.inp 3,813 11-18-2019 15:49 7f23076d bd_ns325a0c00g0s001vfi.out 646,685 11-19-2019 21:20 defd9393 bd_ns325a0c00g0s005vfi.inp 3,813 11-18-2019 15:49 3cac159d bd_ns325a0c00g0s005vfi.out 647,587 11-19-2019 21:10 82656945 bd_ns325a0c00g0s010vfi.inp 3,813 11-18-2019 15:49 ebb17dc9 bd_ns325a0c00g0s010vfi.out 646,506 11-19-2019 21:26 4321affc bd_ns325a0c00g0s030vfi.inp 3,813 11-18-2019 15:49 0a50b4a4 bd_ns325a0c00g0s030vfi.out 646,439 11-19-2019 21:44 5dbcbe8c bd_ns325a0c00g0s050vfi.inp 3,813 11-18-2019 15:49 776b561d bd_ns325a0c00g0s050vfi.out 646,517 11-19-2019 22:11 eb45fba2 bd_ns325a0c00g0s070vfi.inp 3,813 11-18-2019 15:49 8ef1f0ac bd_ns325a0c00g0s070vfi.out 646,789 11-19-2019 21:59 43ee07c8 bd_ns325a0c00g0s090vfi.inp 3,813 11-18-2019 15:49 43aa0939 bd_ns325a0c00g0s090vfi.out 646,084 11-19-2019 22:04 ae591575 bd_ns325a0c00g0s095vfi.inp 3,813 11-18-2019 15:49 9d59c564 bd_ns325a0c00g0s095vfi.out 646,680 11-19-2019 22:21 618d76cd bd_ns325a0c00g0s100vfi.inp 3,813 11-18-2019 15:50 4bd91894 bd_ns325a0c00g0s100vfi.out 647,138 11-19-2019 22:09 5604031d
\\v1.2\\be\\ (0) 41,605,870 11-18-2019 16:54
\\v1.2\\be\\ha245\\ (18) 5,861,649 11-22-2019 12:48 be_ha245a0c00g0s001vfio.inp 3,839 11-18-2019 01:58 dff23e89 be_ha245a0c00g0s001vfio.out 647,299 11-18-2019 11:39 b7302e1d be_ha245a0c00g0s005vfio.inp 3,839 11-18-2019 01:58 4339cfa0 be_ha245a0c00g0s005vfio.out 647,880 11-18-2019 11:44 4ed941f0 be_ha245a0c00g0s010vfio.inp 3,839 11-18-2019 01:58 d4277a83 be_ha245a0c00g0s010vfio.out 647,357 11-18-2019 12:07 1229c9ee be_ha245a0c00g0s030vfio.inp 3,839 11-18-2019 01:58 3eb1ac0a
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
64 of 190 be_ha245a0c00g0s030vfio.out 647,604 11-18-2019 12:40 e98a9a56 be_ha245a0c00g0s050vfio.inp 3,839 11-18-2019 01:58 c1575c80 be_ha245a0c00g0s050vfio.out 647,243 11-18-2019 12:52 e641dc82 be_ha245a0c00g0s070vfio.inp 3,839 11-18-2019 01:58 7a5276ad be_ha245a0c00g0s070vfio.out 647,186 11-18-2019 13:00 7197d9f7 be_ha245a0c00g0s090vfio.inp 3,839 11-18-2019 01:58 6d1dcf86 be_ha245a0c00g0s090vfio.out 647,550 11-18-2019 13:06 a46f4024 be_ha245a0c00g0s095vfio.inp 3,839 11-18-2019 01:59 1d6ed981 be_ha245a0c00g0s095vfio.out 647,449 11-18-2019 13:04 6e789d3e be_ha245a0c00g0s100vfio.inp 3,839 11-18-2019 01:59 06147ff4 be_ha245a0c00g0s100vfio.out 647,530 11-18-2019 13:05 4371e61f
\\v1.2\\be\\ha325\\ (18) 5,853,574 11-22-2019 12:48 be_ha325a0c00g0s001vfio.inp 3,784 11-18-2019 00:05 256d83fc be_ha325a0c00g0s001vfio.out 646,539 11-18-2019 01:56 380574c9 be_ha325a0c00g0s005vfio.inp 3,784 11-18-2019 00:05 fbdbb5ce be_ha325a0c00g0s005vfio.out 646,596 11-18-2019 01:56 0a18cd7a be_ha325a0c00g0s010vfio.inp 3,784 11-18-2019 00:05 6a1d88a3 be_ha325a0c00g0s010vfio.out 646,734 11-18-2019 02:19 0c42ec1a be_ha325a0c00g0s030vfio.inp 3,784 11-18-2019 00:05 48171126 be_ha325a0c00g0s030vfio.out 646,832 11-18-2019 03:00 09a4fd4b be_ha325a0c00g0s050vfio.inp 3,784 11-18-2019 00:06 b32e8991 be_ha325a0c00g0s050vfio.out 646,300 11-18-2019 03:15 4aca6378 be_ha325a0c00g0s070vfio.inp 3,784 11-18-2019 00:06 cb944907 be_ha325a0c00g0s070vfio.out 647,591 11-18-2019 03:27 92a048c7 be_ha325a0c00g0s090vfio.inp 3,784 11-18-2019 00:06 6594059d be_ha325a0c00g0s090vfio.out 646,047 11-18-2019 03:33 5f06cb37 be_ha325a0c00g0s095vfio.inp 3,784 11-18-2019 00:06 f21e1b85 be_ha325a0c00g0s095vfio.out 647,084 11-18-2019 03:35 35a7acf6 be_ha325a0c00g0s100vfio.inp 3,784 11-18-2019 00:06 653c8f60 be_ha325a0c00g0s100vfio.out 645,795 11-18-2019 03:34 e17cc228
\\v1.2\\be\\hs245\\ (18) 4,545,403 11-22-2019 12:48 be_hs245a0c00g0s001vfi.inp 3,867 11-18-2019 14:23 d353ae14 be_hs245a0c00g0s001vfi.out 502,073 11-19-2019 16:40 93b418fc be_hs245a0c00g0s005vfi.inp 3,867 11-18-2019 14:23 8b3b7987 be_hs245a0c00g0s005vfi.out 500,849 11-19-2019 16:38 9c737b56 be_hs245a0c00g0s010vfi.inp 3,867 11-18-2019 14:23 93604368 be_hs245a0c00g0s010vfi.out 501,132 11-19-2019 16:40 45931f8d be_hs245a0c00g0s030vfi.inp 3,867 11-18-2019 14:23 c59685f7 be_hs245a0c00g0s030vfi.out 501,332 11-19-2019 16:45 0fea3693 be_hs245a0c00g0s050vfi.inp 3,867 11-18-2019 14:23 d81f5287 be_hs245a0c00g0s050vfi.out 501,668 11-19-2019 16:59 235bc897 be_hs245a0c00g0s070vfi.inp 3,867 11-18-2019 14:23 10591894 be_hs245a0c00g0s070vfi.out 500,741 11-19-2019 17:08 cf566f6e be_hs245a0c00g0s090vfi.inp 3,867 11-18-2019 14:23 078a8579 be_hs245a0c00g0s090vfi.out 500,216 11-19-2019 17:24 9d73b2f4 be_hs245a0c00g0s095vfi.inp 3,867 11-18-2019 14:23 996e9efa be_hs245a0c00g0s095vfi.out 501,524 11-19-2019 17:11 5b9b4912 be_hs245a0c00g0s100vfi.inp 3,867 11-18-2019 14:23 bc6a01e1 be_hs245a0c00g0s100vfi.out 501,065 11-19-2019 17:14 36e4176a
\\v1.2\\be\\hs325\\ (18) 4,539,914 11-22-2019 12:48 be_hs325a0c00g0s001vfi.inp 3,817 11-18-2019 12:35 0e080323 be_hs325a0c00g0s001vfi.out 500,571 11-19-2019 11:09 e3d43d7e be_hs325a0c00g0s005vfi.inp 3,817 11-18-2019 12:35 a76ce7d9 be_hs325a0c00g0s005vfi.out 500,763 11-19-2019 10:57 aaecad19 be_hs325a0c00g0s010vfi.inp 3,817 11-18-2019 12:35 1d3a7773 be_hs325a0c00g0s010vfi.out 500,135 11-19-2019 10:59 4ed59606 be_hs325a0c00g0s030vfi.inp 3,817 11-18-2019 12:35 6b3bbc63 be_hs325a0c00g0s030vfi.out 500,067 11-19-2019 11:18 f23e9789 be_hs325a0c00g0s050vfi.inp 3,817 11-18-2019 12:35 4c162c5a be_hs325a0c00g0s050vfi.out 501,861 11-19-2019 11:38 300d964b be_hs325a0c00g0s070vfi.inp 3,817 11-18-2019 12:35 165547f0 be_hs325a0c00g0s070vfi.out 500,366 11-19-2019 11:47 3124a1f5 be_hs325a0c00g0s090vfi.inp 3,817 11-18-2019 12:36 7aecc791 be_hs325a0c00g0s090vfi.out 501,240 11-19-2019 11:52 b49c125b be_hs325a0c00g0s095vfi.inp 3,817 11-18-2019 12:36 c76f75f1 be_hs325a0c00g0s095vfi.out 499,920 11-19-2019 11:49 4daa6178 be_hs325a0c00g0s100vfi.inp 3,817 11-18-2019 12:36 eb2948b9 be_hs325a0c00g0s100vfi.out 500,638 11-19-2019 11:48 46ebbabb
\\v1.2\\be\\na245\\ (18) 5,862,632 11-22-2019 12:48 be_na245a0c00g0s001vfio.inp 3,866 11-18-2019 11:12 939ab31c be_na245a0c00g0s001vfio.out 647,548 11-19-2019 02:36 952abce6 be_na245a0c00g0s005vfio.inp 3,866 11-18-2019 11:12 cb4f02a1 be_na245a0c00g0s005vfio.out 647,637 11-19-2019 02:49 8c72e66c
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
65 of 190 be_na245a0c00g0s010vfio.inp 3,866 11-18-2019 11:12 9d0012fb be_na245a0c00g0s010vfio.out 646,775 11-19-2019 03:18 81bff433 be_na245a0c00g0s030vfio.inp 3,866 11-18-2019 11:12 8b578b09 be_na245a0c00g0s030vfio.out 647,799 11-19-2019 04:10 d6905e79 be_na245a0c00g0s050vfio.inp 3,866 11-18-2019 11:12 3bce1cb6 be_na245a0c00g0s050vfio.out 647,840 11-19-2019 04:16 a32e0928 be_na245a0c00g0s070vfio.inp 3,866 11-18-2019 11:12 c1b10366 be_na245a0c00g0s070vfio.out 646,810 11-19-2019 04:14 9f9d76bb be_na245a0c00g0s090vfio.inp 3,866 11-18-2019 11:12 a880f550 be_na245a0c00g0s090vfio.out 648,156 11-19-2019 04:22 96d72e1c be_na245a0c00g0s095vfio.inp 3,866 11-18-2019 11:12 06360b7a be_na245a0c00g0s095vfio.out 647,145 11-19-2019 04:23 e0c9eb4f be_na245a0c00g0s100vfio.inp 3,866 11-18-2019 11:12 76901453 be_na245a0c00g0s100vfio.out 648,128 11-19-2019 04:22 1a93da72
\\v1.2\\be\\na325\\ (18) 5,855,079 11-22-2019 12:48 be_na325a0c00g0s001vfio.inp 3,816 11-18-2019 10:10 76708b14 be_na325a0c00g0s001vfio.out 647,161 11-18-2019 18:11 ba5431a9 be_na325a0c00g0s005vfio.inp 3,816 11-18-2019 10:10 51e871b6 be_na325a0c00g0s005vfio.out 647,616 11-18-2019 18:18 72a32f84 be_na325a0c00g0s010vfio.inp 3,816 11-18-2019 10:10 74eb5490 be_na325a0c00g0s010vfio.out 646,307 11-18-2019 18:42 952dfcde be_na325a0c00g0s030vfio.inp 3,816 11-18-2019 10:10 3bfb2cb0 be_na325a0c00g0s030vfio.out 646,521 11-18-2019 19:30 e4ce21ec be_na325a0c00g0s050vfio.inp 3,816 11-18-2019 10:10 3bc6a013 be_na325a0c00g0s050vfio.out 646,842 11-18-2019 19:50 3bdd0eb7 be_na325a0c00g0s070vfio.inp 3,816 11-18-2019 10:10 a15c998c be_na325a0c00g0s070vfio.out 646,750 11-18-2019 20:05 c11252d5 be_na325a0c00g0s090vfio.inp 3,816 11-18-2019 10:10 4962e53d be_na325a0c00g0s090vfio.out 646,605 11-18-2019 20:00 c6722246 be_na325a0c00g0s095vfio.inp 3,816 11-18-2019 10:10 a9f1b213 be_na325a0c00g0s095vfio.out 646,297 11-18-2019 19:56 ffb5dd33 be_na325a0c00g0s100vfio.inp 3,816 11-18-2019 10:11 a408b1fe be_na325a0c00g0s100vfio.out 646,636 11-18-2019 20:13 b41396a5
\\v1.2\\be\\ns245\\ (18) 4,550,337 11-22-2019 12:48 be_ns245a0c00g0s001vfi.inp 3,867 11-18-2019 16:54 5ac11742 be_ns245a0c00g0s001vfi.out 502,352 11-20-2019 02:52 6c7ffd6e be_ns245a0c00g0s005vfi.inp 3,867 11-18-2019 16:54 02a9c0d1 be_ns245a0c00g0s005vfi.out 501,637 11-20-2019 02:40 14454f05 be_ns245a0c00g0s010vfi.inp 3,867 11-18-2019 16:54 1af2fa3e be_ns245a0c00g0s010vfi.out 501,866 11-20-2019 02:46 e5e3248b be_ns245a0c00g0s030vfi.inp 3,867 11-18-2019 16:54 4c043ca1 be_ns245a0c00g0s030vfi.out 501,306 11-20-2019 03:09 63d8bae3 be_ns245a0c00g0s050vfi.inp 3,867 11-18-2019 16:54 518debd1 be_ns245a0c00g0s050vfi.out 501,372 11-20-2019 03:21 73a19da1 be_ns245a0c00g0s070vfi.inp 3,867 11-18-2019 16:55 99cba1c2 be_ns245a0c00g0s070vfi.out 502,333 11-20-2019 03:16 7c48b533 be_ns245a0c00g0s090vfi.inp 3,867 11-18-2019 16:55 8e183c2f be_ns245a0c00g0s090vfi.out 500,771 11-20-2019 03:27 c0ccbd94 be_ns245a0c00g0s095vfi.inp 3,867 11-18-2019 16:55 10fc27ac be_ns245a0c00g0s095vfi.out 501,754 11-20-2019 03:33 03f4b104 be_ns245a0c00g0s100vfi.inp 3,867 11-18-2019 16:55 35f8b8b7 be_ns245a0c00g0s100vfi.out 502,143 11-20-2019 03:31 3bedd4f6
\\v1.2\\be\\ns325\\ (18) 4,537,282 11-22-2019 12:48 be_ns325a0c00g0s001vfi.inp 3,817 11-18-2019 15:50 dcee54d2 be_ns325a0c00g0s001vfi.out 500,416 11-19-2019 21:25 92c3402c be_ns325a0c00g0s005vfi.inp 3,817 11-18-2019 15:50 758ab028 be_ns325a0c00g0s005vfi.out 500,612 11-19-2019 21:22 964555a9 be_ns325a0c00g0s010vfi.inp 3,817 11-18-2019 15:50 cfdc2082 be_ns325a0c00g0s010vfi.out 500,438 11-19-2019 21:27 f96b4dee be_ns325a0c00g0s030vfi.inp 3,817 11-18-2019 15:50 b9ddeb92 be_ns325a0c00g0s030vfi.out 500,021 11-19-2019 21:57 8201ba45 be_ns325a0c00g0s050vfi.inp 3,817 11-18-2019 15:50 9ef07bab be_ns325a0c00g0s050vfi.out 500,128 11-19-2019 22:05 1d16d82d be_ns325a0c00g0s070vfi.inp 3,817 11-18-2019 15:50 c4b31001 be_ns325a0c00g0s070vfi.out 500,230 11-19-2019 22:27 a7f18bc2 be_ns325a0c00g0s090vfi.inp 3,817 11-18-2019 15:50 a80a9060 be_ns325a0c00g0s090vfi.out 500,319 11-19-2019 22:14 7625fa28 be_ns325a0c00g0s095vfi.inp 3,817 11-18-2019 15:50 15892200 be_ns325a0c00g0s095vfi.out 500,068 11-19-2019 22:16 ccee407f be_ns325a0c00g0s100vfi.inp 3,817 11-18-2019 15:51 39cf1f48 be_ns325a0c00g0s100vfi.out 500,697 11-19-2019 22:21 c0918ee1
\\v1.2\\bf\\ (0) 28,478,956 11-18-2019 15:32
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
66 of 190
\\v1.2\\bf\\ha245\\ (22) 7,111,802 11-18-2019 20:33 bf_ha245a0c00g0s0500hx.inp 3,311 11-18-2019 09:59 2f382e49 bf_ha245a0c00g0s0500hx.out 643,991 11-18-2019 16:08 7b3a2e47 bf_ha245a0c00g0s0600hx.inp 3,312 11-18-2019 09:59 cd02ddfa bf_ha245a0c00g0s0600hx.out 644,280 11-18-2019 15:51 a1f70255 bf_ha245a0c00g0s0700hx.inp 3,312 11-18-2019 09:59 2c4d1811 bf_ha245a0c00g0s0700hx.out 643,713 11-18-2019 15:32 3d4dccfb bf_ha245a0c00g0s0800hx.inp 3,312 11-18-2019 09:59 e8806c2a bf_ha245a0c00g0s0800hx.out 643,005 11-18-2019 15:17 5a1a5ba0 bf_ha245a0c00g0s0900hx.inp 3,312 11-18-2019 09:59 08925e70 bf_ha245a0c00g0s0900hx.out 642,896 11-18-2019 15:10 1f117dbe bf_ha245a0c00g0s1000hx.inp 3,316 11-18-2019 09:59 20de78b7 bf_ha245a0c00g0s1000hx.out 643,510 11-18-2019 15:00 5959bd72 bf_ha245a0c00g0s1100hx.inp 3,316 11-18-2019 09:59 74df75f6 bf_ha245a0c00g0s1100hx.out 642,216 11-18-2019 14:50 c2096d6f bf_ha245a0c00g0s1200hx.inp 3,316 11-18-2019 09:59 4203a5f0 bf_ha245a0c00g0s1200hx.out 642,759 11-18-2019 14:47 db50a6be bf_ha245a0c00g0s1300hx.inp 3,316 11-18-2019 09:59 933c294d bf_ha245a0c00g0s1300hx.out 643,287 11-18-2019 14:35 61e68d43 bf_ha245a0c00g0s1400hx.inp 3,316 11-18-2019 10:00 8a22de0b bf_ha245a0c00g0s1400hx.out 642,900 11-18-2019 14:29 73c68032 bf_ha245a0c00g0s1500hx.inp 3,316 11-18-2019 10:00 4a9b5fc5 bf_ha245a0c00g0s1500hx.out 642,790 11-18-2019 14:15 70632d6d
\\v1.2\\bf\\ha325\\ (22) 7,128,035 11-18-2019 20:33 bf_ha325a0c00g0s0500hx.inp 3,395 11-18-2019 01:47 b857cecf bf_ha325a0c00g0s0500hx.out 644,670 11-18-2019 09:59 c8539aeb bf_ha325a0c00g0s0600hx.inp 3,395 11-18-2019 01:47 ecd61d3d bf_ha325a0c00g0s0600hx.out 644,302 11-18-2019 11:01 aa36b32e bf_ha325a0c00g0s0700hx.inp 3,395 11-18-2019 01:47 6f171111 bf_ha325a0c00g0s0700hx.out 644,940 11-18-2019 10:27 c19f612f bf_ha325a0c00g0s0800hx.inp 3,395 11-18-2019 01:47 31b1a2c6 bf_ha325a0c00g0s0800hx.out 644,242 11-18-2019 09:06 546f1837 bf_ha325a0c00g0s0900hx.inp 3,395 11-18-2019 01:47 c797abd8 bf_ha325a0c00g0s0900hx.out 644,644 11-18-2019 09:08 2d7dd3b5 bf_ha325a0c00g0s1000hx.inp 3,399 11-18-2019 01:47 3dd632ee bf_ha325a0c00g0s1000hx.out 644,865 11-18-2019 09:44 11bd6d0b bf_ha325a0c00g0s1100hx.inp 3,399 11-18-2019 01:48 1fa2011d bf_ha325a0c00g0s1100hx.out 644,544 11-18-2019 09:43 03f5142d bf_ha325a0c00g0s1200hx.inp 3,399 11-18-2019 01:48 cabd8c3d bf_ha325a0c00g0s1200hx.out 644,257 11-18-2019 08:54 0e635d0c bf_ha325a0c00g0s1300hx.inp 3,399 11-18-2019 01:48 8c6626fd bf_ha325a0c00g0s1300hx.out 644,034 11-18-2019 08:57 2ff6ff63 bf_ha325a0c00g0s1400hx.inp 3,399 11-18-2019 01:48 34a4660a bf_ha325a0c00g0s1400hx.out 645,037 11-18-2019 09:27 7a9d9363 bf_ha325a0c00g0s1500hx.inp 3,399 11-18-2019 01:48 9b1f7ab5 bf_ha325a0c00g0s1500hx.out 645,131 11-18-2019 09:10 49fd8c9c
\\v1.2\\bf\\na245\\ (22) 7,114,459 11-20-2019 09:22 bf_na245a0c00g0s0500hx.inp 3,311 11-18-2019 12:09 b866649f bf_na245a0c00g0s0500hx.out 644,101 11-19-2019 06:23 7bda75c4 bf_na245a0c00g0s0600hx.inp 3,312 11-18-2019 12:09 53b03fab bf_na245a0c00g0s0600hx.out 644,235 11-19-2019 05:56 d1eac6d7 bf_na245a0c00g0s0700hx.inp 3,312 11-18-2019 12:10 b2fffa40 bf_na245a0c00g0s0700hx.out 641,973 11-19-2019 06:02 170625b1 bf_na245a0c00g0s0800hx.inp 3,312 11-18-2019 12:10 76328e7b bf_na245a0c00g0s0800hx.out 643,334 11-19-2019 05:44 c289b690 bf_na245a0c00g0s0900hx.inp 3,312 11-18-2019 12:10 9620bc21 bf_na245a0c00g0s0900hx.out 643,841 11-19-2019 05:37 de579f4b bf_na245a0c00g0s1000hx.inp 3,316 11-18-2019 12:10 9a47d6fa bf_na245a0c00g0s1000hx.out 643,636 11-19-2019 05:24 5d7beb0d bf_na245a0c00g0s1100hx.inp 3,316 11-18-2019 12:10 ce46dbbb bf_na245a0c00g0s1100hx.out 643,647 11-19-2019 05:21 119ac208 bf_na245a0c00g0s1200hx.inp 3,316 11-18-2019 12:10 f89a0bbd bf_na245a0c00g0s1200hx.out 643,293 11-19-2019 05:18 4eb5e985 bf_na245a0c00g0s1300hx.inp 3,316 11-18-2019 12:10 29a58700 bf_na245a0c00g0s1300hx.out 644,367 11-19-2019 05:15 b525305a bf_na245a0c00g0s1400hx.inp 3,316 11-18-2019 12:10 30bb7046 bf_na245a0c00g0s1400hx.out 642,597 11-19-2019 05:42 0c7237cc bf_na245a0c00g0s1500hx.inp 3,316 11-18-2019 12:10 f002f188 bf_na245a0c00g0s1500hx.out 642,980 11-19-2019 05:07 b7942b44
\\v1.2\\bf\\na325\\ (22) 7,124,660 11-20-2019 09:22 bf_na325a0c00g0s0500hx.inp 3,416 11-18-2019 11:04 9cdbf059 bf_na325a0c00g0s0500hx.out 644,616 11-18-2019 22:02 d84e9866 bf_na325a0c00g0s0600hx.inp 3,416 11-18-2019 11:04 7fe06160 bf_na325a0c00g0s0600hx.out 644,257 11-18-2019 21:40 f3229059
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
67 of 190 bf_na325a0c00g0s0700hx.inp 3,416 11-18-2019 11:04 bc7ffa78 bf_na325a0c00g0s0700hx.out 645,563 11-18-2019 21:22 9294b66a bf_na325a0c00g0s0800hx.inp 3,416 11-18-2019 11:05 6438e611 bf_na325a0c00g0s0800hx.out 644,717 11-18-2019 21:16 c1cd7040 bf_na325a0c00g0s0900hx.inp 3,416 11-18-2019 11:05 3ffdf54e bf_na325a0c00g0s0900hx.out 643,213 11-18-2019 21:25 7baf9869 bf_na325a0c00g0s1000hx.inp 3,420 11-18-2019 11:05 57e511d6 bf_na325a0c00g0s1000hx.out 643,140 11-18-2019 20:57 40e7e851 bf_na325a0c00g0s1100hx.inp 3,420 11-18-2019 11:05 c03a1b1b bf_na325a0c00g0s1100hx.out 643,236 11-18-2019 20:53 98c0d6a4 bf_na325a0c00g0s1200hx.inp 3,420 11-18-2019 11:05 bfa941f6 bf_na325a0c00g0s1200hx.out 644,313 11-18-2019 21:19 eac3ece4 bf_na325a0c00g0s1300hx.inp 3,420 11-18-2019 11:05 e45b53ed bf_na325a0c00g0s1300hx.out 645,643 11-18-2019 20:58 1d834131 bf_na325a0c00g0s1400hx.inp 3,420 11-18-2019 11:05 a836ddb5 bf_na325a0c00g0s1400hx.out 644,300 11-18-2019 21:12 29bd7597 bf_na325a0c00g0s1500hx.inp 3,420 11-18-2019 11:05 9976c2ba bf_na325a0c00g0s1500hx.out 644,062 11-18-2019 21:07 22b0721d
\\v1.2\\bg\\ (0) 28,471,654 11-18-2019 15:32
\\v1.2\\bg\\ha245\\ (22) 7,110,321 11-18-2019 20:33 bg_ha245a0c00g0s0500hx.inp 3,307 11-18-2019 10:00 1ec6db70 bg_ha245a0c00g0s0500hx.out 642,883 11-18-2019 16:02 d345c27a bg_ha245a0c00g0s0600hx.inp 3,308 11-18-2019 10:00 2ba54b05 bg_ha245a0c00g0s0600hx.out 642,259 11-18-2019 15:46 88e89a15 bg_ha245a0c00g0s0700hx.inp 3,308 11-18-2019 10:00 74368742 bg_ha245a0c00g0s0700hx.out 642,975 11-18-2019 15:29 2637bed5 bg_ha245a0c00g0s0800hx.inp 3,308 11-18-2019 10:00 bca03167 bg_ha245a0c00g0s0800hx.out 642,245 11-18-2019 15:16 4092fc5f bg_ha245a0c00g0s0900hx.inp 3,308 11-18-2019 10:00 927828e8 bg_ha245a0c00g0s0900hx.out 643,703 11-18-2019 15:07 a3ee8b7f bg_ha245a0c00g0s1000hx.inp 3,312 11-18-2019 10:00 4073d844 bg_ha245a0c00g0s1000hx.out 642,697 11-18-2019 14:56 5576f7dd bg_ha245a0c00g0s1100hx.inp 3,312 11-18-2019 10:00 6f5c854c bg_ha245a0c00g0s1100hx.out 643,547 11-18-2019 14:52 e284d971 bg_ha245a0c00g0s1200hx.inp 3,312 11-18-2019 10:00 68a4339c bg_ha245a0c00g0s1200hx.out 642,411 11-18-2019 14:45 116cb0a5 bg_ha245a0c00g0s1300hx.inp 3,312 11-18-2019 10:00 f4d09cd7 bg_ha245a0c00g0s1300hx.out 643,668 11-18-2019 14:31 2a616190 bg_ha245a0c00g0s1400hx.inp 3,312 11-18-2019 10:00 c10c85c2 bg_ha245a0c00g0s1400hx.out 643,727 11-18-2019 14:28 f566fc85 bg_ha245a0c00g0s1500hx.inp 3,312 11-18-2019 10:01 8acac51b bg_ha245a0c00g0s1500hx.out 643,795 11-18-2019 14:13 26d00897
\\v1.2\\bg\\ha325\\ (22) 7,124,958 11-18-2019 20:33 bg_ha325a0c00g0s0500hx.inp 3,391 11-18-2019 01:48 d32055e1 bg_ha325a0c00g0s0500hx.out 644,817 11-18-2019 10:58 5eab285d bg_ha325a0c00g0s0600hx.inp 3,391 11-18-2019 01:48 04746524 bg_ha325a0c00g0s0600hx.out 645,001 11-18-2019 09:25 685691a9 bg_ha325a0c00g0s0700hx.inp 3,391 11-18-2019 01:48 2c7555e6 bg_ha325a0c00g0s0700hx.out 644,719 11-18-2019 09:59 6b5d8526 bg_ha325a0c00g0s0800hx.inp 3,391 11-18-2019 01:48 06aa53bb bg_ha325a0c00g0s0800hx.out 643,483 11-18-2019 09:48 7bc967d6 bg_ha325a0c00g0s0900hx.inp 3,391 11-18-2019 01:48 08ad0381 bg_ha325a0c00g0s0900hx.out 644,008 11-18-2019 09:36 5b67324e bg_ha325a0c00g0s1000hx.inp 3,395 11-18-2019 01:48 b5f3d840 bg_ha325a0c00g0s1000hx.out 644,570 11-18-2019 10:03 8d9cdaae bg_ha325a0c00g0s1100hx.inp 3,395 11-18-2019 01:48 3c755683 bg_ha325a0c00g0s1100hx.out 645,269 11-18-2019 09:56 0d0fbbaf bg_ha325a0c00g0s1200hx.inp 3,395 11-18-2019 01:49 cefb93fe bg_ha325a0c00g0s1200hx.out 643,979 11-18-2019 09:09 1c80a635 bg_ha325a0c00g0s1300hx.inp 3,395 11-18-2019 01:49 e990bb56 bg_ha325a0c00g0s1300hx.out 644,296 11-18-2019 09:55 90274849 bg_ha325a0c00g0s1400hx.inp 3,395 11-18-2019 01:49 b8aaaa10 bg_ha325a0c00g0s1400hx.out 643,761 11-18-2019 10:18 2cd248cf bg_ha325a0c00g0s1500hx.inp 3,395 11-18-2019 01:49 c0c98036 bg_ha325a0c00g0s1500hx.out 643,730 11-18-2019 10:16 af56d962
\\v1.2\\bg\\na245\\ (22) 7,110,665 11-20-2019 09:22 bg_na245a0c00g0s0500hx.inp 3,307 11-18-2019 12:10 c7f83690 bg_na245a0c00g0s0500hx.out 642,570 11-19-2019 06:26 5d896525 bg_na245a0c00g0s0600hx.inp 3,308 11-18-2019 12:10 7ae35c6a bg_na245a0c00g0s0600hx.out 643,805 11-19-2019 06:15 a3862a26 bg_na245a0c00g0s0700hx.inp 3,308 11-18-2019 12:11 2570902d bg_na245a0c00g0s0700hx.out 642,671 11-19-2019 06:10 c2649093 bg_na245a0c00g0s0800hx.inp 3,308 11-18-2019 12:11 ede62608
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
68 of 190 bg_na245a0c00g0s0800hx.out 643,150 11-19-2019 06:17 55d9df0c bg_na245a0c00g0s0900hx.inp 3,308 11-18-2019 12:11 c33e3f87 bg_na245a0c00g0s0900hx.out 643,528 11-19-2019 05:36 033ea11d bg_na245a0c00g0s1000hx.inp 3,312 11-18-2019 12:11 e8e1a294 bg_na245a0c00g0s1000hx.out 642,963 11-19-2019 05:14 0330b5a1 bg_na245a0c00g0s1100hx.inp 3,312 11-18-2019 12:11 c7ceff9c bg_na245a0c00g0s1100hx.out 643,289 11-19-2019 05:33 6cb1d6f9 bg_na245a0c00g0s1200hx.inp 3,312 11-18-2019 12:11 c036494c bg_na245a0c00g0s1200hx.out 642,451 11-19-2019 05:11 f88e73b6 bg_na245a0c00g0s1300hx.inp 3,312 11-18-2019 12:11 5c42e607 bg_na245a0c00g0s1300hx.out 643,310 11-19-2019 05:10 4d3e5183 bg_na245a0c00g0s1400hx.inp 3,312 11-18-2019 12:11 699eff12 bg_na245a0c00g0s1400hx.out 643,076 11-19-2019 05:11 99c986a1 bg_na245a0c00g0s1500hx.inp 3,312 11-18-2019 12:11 2258bfcb bg_na245a0c00g0s1500hx.out 643,441 11-19-2019 05:05 9e2bd8ad
\\v1.2\\bg\\na325\\ (22) 7,125,710 11-20-2019 09:22 bg_na325a0c00g0s0500hx.inp 3,412 11-18-2019 11:05 0b08d687 bg_na325a0c00g0s0500hx.out 643,942 11-18-2019 22:22 95ee2d43 bg_na325a0c00g0s0600hx.inp 3,412 11-18-2019 11:05 150f5205 bg_na325a0c00g0s0600hx.out 644,928 11-18-2019 21:40 4a004ba5 bg_na325a0c00g0s0700hx.inp 3,412 11-18-2019 11:05 65ddad68 bg_na325a0c00g0s0700hx.out 644,353 11-18-2019 21:51 5a9f21f9 bg_na325a0c00g0s0800hx.inp 3,412 11-18-2019 11:05 7f5eb4fe bg_na325a0c00g0s0800hx.out 644,269 11-18-2019 21:31 74019d29 bg_na325a0c00g0s0900hx.inp 3,412 11-18-2019 11:06 e425ff82 bg_na325a0c00g0s0900hx.out 644,221 11-18-2019 21:34 ef91fd63 bg_na325a0c00g0s1000hx.inp 3,416 11-18-2019 11:06 0c8c3d35 bg_na325a0c00g0s1000hx.out 644,520 11-18-2019 21:27 b79a3bf5 bg_na325a0c00g0s1100hx.inp 3,416 11-18-2019 11:06 5017d3bc bg_na325a0c00g0s1100hx.out 643,685 11-18-2019 21:05 050314c5 bg_na325a0c00g0s1200hx.inp 3,416 11-18-2019 11:06 4c02ff92 bg_na325a0c00g0s1200hx.out 644,212 11-18-2019 21:06 37e3b6cc bg_na325a0c00g0s1300hx.inp 3,416 11-18-2019 11:06 76cbcf0a bg_na325a0c00g0s1300hx.out 644,032 11-18-2019 21:21 b681dcb7 bg_na325a0c00g0s1400hx.inp 3,416 11-18-2019 11:06 edc6ce9a bg_na325a0c00g0s1400hx.out 644,524 11-18-2019 21:04 014995ba bg_na325a0c00g0s1500hx.inp 3,416 11-18-2019 11:06 4a761cc1 bg_na325a0c00g0s1500hx.out 645,468 11-18-2019 20:43 f3f4fbdb
\\v1.2\\ca\\ (0) 171,886,823 11-18-2019 16:55
\\v1.2\\ca\\ha245\\ (66) 21,741,129 11-18-2019 20:33 ca_ha245a2c32g1s0500hx.inp 4,047 11-18-2019 01:59 4e400c4d ca_ha245a2c32g1s0500hx.out 654,526 11-18-2019 13:07 f46cf6e9 ca_ha245a2c32g1s0600hx.inp 4,048 11-18-2019 01:59 06bd3ccf ca_ha245a2c32g1s0600hx.out 654,617 11-18-2019 12:59 fa70a25e ca_ha245a2c32g1s0700hx.inp 4,048 11-18-2019 01:59 51fc5cc9 ca_ha245a2c32g1s0700hx.out 655,197 11-18-2019 13:01 200de657 ca_ha245a2c32g1s0800hx.inp 4,048 11-18-2019 01:59 7e1c9ed7 ca_ha245a2c32g1s0800hx.out 653,890 11-18-2019 13:03 0e753b70 ca_ha245a2c32g1s0900hx.inp 4,048 11-18-2019 01:59 e6aa6294 ca_ha245a2c32g1s0900hx.out 654,644 11-18-2019 12:57 433a4206 ca_ha245a2c32g1s1000hx.inp 4,052 11-18-2019 01:59 4c77a48c ca_ha245a2c32g1s1000hx.out 654,713 11-18-2019 12:58 f4cf966d ca_ha245a2c32g1s1100hx.inp 4,052 11-18-2019 01:59 e828eafd ca_ha245a2c32g1s1100hx.out 654,779 11-18-2019 13:03 eaa7edf8 ca_ha245a2c32g1s1200hx.inp 4,052 11-18-2019 01:59 c4412bd3 ca_ha245a2c32g1s1200hx.out 654,859 11-18-2019 12:59 145df5ae ca_ha245a2c32g1s1300hx.inp 4,052 11-18-2019 02:00 1f63d73a ca_ha245a2c32g1s1300hx.out 654,184 11-18-2019 12:59 71e95f8e ca_ha245a2c32g1s1400hx.inp 4,052 11-18-2019 02:00 7dc0ddcb ca_ha245a2c32g1s1400hx.out 653,765 11-18-2019 13:05 81728240 ca_ha245a2c32g1s1500hx.inp 4,052 11-18-2019 02:00 b0705ddf ca_ha245a2c32g1s1500hx.out 654,906 11-18-2019 13:03 4e2c7060 ca_ha245a2c32g2s0500hx.inp 4,045 11-18-2019 02:00 87854b1b ca_ha245a2c32g2s0500hx.out 654,417 11-18-2019 13:43 83ef6f46 ca_ha245a2c32g2s0600hx.inp 4,046 11-18-2019 02:00 3456875e ca_ha245a2c32g2s0600hx.out 655,190 11-18-2019 13:46 feaf2246 ca_ha245a2c32g2s0700hx.inp 4,046 11-18-2019 02:00 e78ececa ca_ha245a2c32g2s0700hx.out 654,832 11-18-2019 13:36 2fd51776 ca_ha245a2c32g2s0800hx.inp 4,046 11-18-2019 02:00 591c8771 ca_ha245a2c32g2s0800hx.out 655,231 11-18-2019 13:34 6b656e06 ca_ha245a2c32g2s0900hx.inp 4,046 11-18-2019 02:00 0d2c58fb ca_ha245a2c32g2s0900hx.out 654,836 11-18-2019 13:38 66c39a0f ca_ha245a2c32g2s1000hx.inp 4,050 11-18-2019 02:00 54894d92 ca_ha245a2c32g2s1000hx.out 654,827 11-18-2019 13:30 438cd0e7 ca_ha245a2c32g2s1100hx.inp 4,050 11-18-2019 02:00 5ef56e5e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
69 of 190 ca_ha245a2c32g2s1100hx.out 654,315 11-18-2019 13:29 381ae6e5 ca_ha245a2c32g2s1200hx.inp 4,050 11-18-2019 02:00 56f31522 ca_ha245a2c32g2s1200hx.out 655,516 11-18-2019 13:35 c21984d9 ca_ha245a2c32g2s1300hx.inp 4,050 11-18-2019 02:00 ff517596 ca_ha245a2c32g2s1300hx.out 655,626 11-18-2019 13:27 0cea3a5d ca_ha245a2c32g2s1400hx.inp 4,050 11-18-2019 02:01 c90672c7 ca_ha245a2c32g2s1400hx.out 656,417 11-18-2019 13:29 2f633134 ca_ha245a2c32g2s1500hx.inp 4,050 11-18-2019 02:01 efdafd32 ca_ha245a2c32g2s1500hx.out 654,721 11-18-2019 13:34 3d514171 ca_ha245a2c32g3s0500hx.inp 4,042 11-18-2019 02:01 35a44b60 ca_ha245a2c32g3s0500hx.out 655,384 11-18-2019 13:18 a38654dc ca_ha245a2c32g3s0600hx.inp 4,043 11-18-2019 02:01 2052f59d ca_ha245a2c32g3s0600hx.out 654,735 11-18-2019 13:16 13d71eb7 ca_ha245a2c32g3s0700hx.inp 4,043 11-18-2019 02:01 4f079b8e ca_ha245a2c32g3s0700hx.out 654,475 11-18-2019 13:18 89ee31ae ca_ha245a2c32g3s0800hx.inp 4,043 11-18-2019 02:01 511bf995 ca_ha245a2c32g3s0800hx.out 654,326 11-18-2019 13:13 47cbece9 ca_ha245a2c32g3s0900hx.inp 4,043 11-18-2019 02:01 0dc47f40 ca_ha245a2c32g3s0900hx.out 654,513 11-18-2019 13:11 4361e047 ca_ha245a2c32g3s1000hx.inp 4,047 11-18-2019 02:01 ac6a571c ca_ha245a2c32g3s1000hx.out 654,615 11-18-2019 13:18 27321484 ca_ha245a2c32g3s1100hx.inp 4,047 11-18-2019 02:01 3a5cb84b ca_ha245a2c32g3s1100hx.out 653,847 11-18-2019 13:13 a2fbbe3b ca_ha245a2c32g3s1200hx.inp 4,047 11-18-2019 02:01 74d43d76 ca_ha245a2c32g3s1200hx.out 655,496 11-18-2019 13:19 4765498e ca_ha245a2c32g3s1300hx.inp 4,047 11-18-2019 02:01 7b832e3a ca_ha245a2c32g3s1300hx.out 654,969 11-18-2019 13:12 b5ec8f95 ca_ha245a2c32g3s1400hx.inp 4,047 11-18-2019 02:02 ccf09570 ca_ha245a2c32g3s1400hx.out 653,918 11-18-2019 13:22 7f92879e ca_ha245a2c32g3s1500hx.inp 4,047 11-18-2019 02:02 935ad7de ca_ha245a2c32g3s1500hx.out 655,267 11-18-2019 13:15 3c960c40
\\v1.2\\ca\\ha325\\ (66) 21,704,925 11-18-2019 20:33 ca_ha325a2c32g1s0500hx.inp 3,993 11-18-2019 00:06 332e0d50 ca_ha325a2c32g1s0500hx.out 653,949 11-18-2019 03:11 255785b6 ca_ha325a2c32g1s0600hx.inp 3,993 11-18-2019 00:06 a6178e65 ca_ha325a2c32g1s0600hx.out 652,959 11-18-2019 03:17 9b79c0b4 ca_ha325a2c32g1s0700hx.inp 3,993 11-18-2019 00:06 57af908f ca_ha325a2c32g1s0700hx.out 653,625 11-18-2019 03:12 a60d89cb ca_ha325a2c32g1s0800hx.inp 3,993 11-18-2019 00:06 b8492e2d ca_ha325a2c32g1s0800hx.out 653,935 11-18-2019 03:06 48dd97c6 ca_ha325a2c32g1s0900hx.inp 3,993 11-18-2019 00:06 1b87cb91 ca_ha325a2c32g1s0900hx.out 653,259 11-18-2019 03:15 85709459 ca_ha325a2c32g1s1000hx.inp 3,997 11-18-2019 00:06 40160249 ca_ha325a2c32g1s1000hx.out 653,457 11-18-2019 03:12 480f67f4 ca_ha325a2c32g1s1100hx.inp 3,997 11-18-2019 00:07 91e7e9d1 ca_ha325a2c32g1s1100hx.out 652,833 11-18-2019 03:10 29b0aba1 ca_ha325a2c32g1s1200hx.inp 3,997 11-18-2019 00:07 b4cf9f39 ca_ha325a2c32g1s1200hx.out 654,026 11-18-2019 03:16 30ef59f4 ca_ha325a2c32g1s1300hx.inp 3,997 11-18-2019 00:07 f2c57948 ca_ha325a2c32g1s1300hx.out 654,081 11-18-2019 03:15 09b99bbc ca_ha325a2c32g1s1400hx.inp 3,997 11-18-2019 00:07 b6a5cf50 ca_ha325a2c32g1s1400hx.out 653,307 11-18-2019 03:10 1d3317e4 ca_ha325a2c32g1s1500hx.inp 3,996 11-18-2019 00:07 d530ef73 ca_ha325a2c32g1s1500hx.out 653,464 11-18-2019 03:20 7c0549e3 ca_ha325a2c32g2s0500hx.inp 3,991 11-18-2019 00:07 768a512b ca_ha325a2c32g2s0500hx.out 653,164 11-18-2019 03:58 71c93c6a ca_ha325a2c32g2s0600hx.inp 3,991 11-18-2019 00:07 36ece637 ca_ha325a2c32g2s0600hx.out 654,386 11-18-2019 03:43 362619e0 ca_ha325a2c32g2s0700hx.inp 3,991 11-18-2019 00:07 4e246826 ca_ha325a2c32g2s0700hx.out 654,339 11-18-2019 03:53 942e2392 ca_ha325a2c32g2s0800hx.inp 3,991 11-18-2019 00:07 9faaec3b ca_ha325a2c32g2s0800hx.out 654,247 11-18-2019 03:48 670ede0e ca_ha325a2c32g2s0900hx.inp 3,991 11-18-2019 00:07 82a3fccf ca_ha325a2c32g2s0900hx.out 653,154 11-18-2019 03:36 f491ca32 ca_ha325a2c32g2s1000hx.inp 3,995 11-18-2019 00:07 9a605a18 ca_ha325a2c32g2s1000hx.out 654,153 11-18-2019 03:47 e1de82c2 ca_ha325a2c32g2s1100hx.inp 3,995 11-18-2019 00:07 8893db37 ca_ha325a2c32g2s1100hx.out 653,820 11-18-2019 03:43 d799a09d ca_ha325a2c32g2s1200hx.inp 3,995 11-18-2019 00:08 6d55d68e ca_ha325a2c32g2s1200hx.out 653,888 11-18-2019 03:32 1d2d905f ca_ha325a2c32g2s1300hx.inp 3,995 11-18-2019 00:08 63191e70 ca_ha325a2c32g2s1300hx.out 655,217 11-18-2019 03:44 a2aa2aa7 ca_ha325a2c32g2s1400hx.inp 3,995 11-18-2019 00:08 35b1afe6 ca_ha325a2c32g2s1400hx.out 654,117 11-18-2019 03:42 4dcc9a89 ca_ha325a2c32g2s1500hx.inp 3,995 11-18-2019 00:08 e2a7f48b ca_ha325a2c32g2s1500hx.out 653,275 11-18-2019 03:33 92cdf2ef ca_ha325a2c32g3s0500hx.inp 3,988 11-18-2019 00:08 270e5903 ca_ha325a2c32g3s0500hx.out 654,527 11-18-2019 03:37 ed7df7b3 ca_ha325a2c32g3s0600hx.inp 3,988 11-18-2019 00:08 52a71fe9
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
70 of 190 ca_ha325a2c32g3s0600hx.out 653,468 11-18-2019 03:30 031bb5da ca_ha325a2c32g3s0700hx.inp 3,988 11-18-2019 00:08 f5682395 ca_ha325a2c32g3s0700hx.out 653,543 11-18-2019 03:19 2784698a ca_ha325a2c32g3s0800hx.inp 3,988 11-18-2019 00:08 8d06a880 ca_ha325a2c32g3s0800hx.out 653,294 11-18-2019 03:31 256e3fd3 ca_ha325a2c32g3s0900hx.inp 3,988 11-18-2019 00:08 e54fd275 ca_ha325a2c32g3s0900hx.out 654,275 11-18-2019 03:18 b13bcb41 ca_ha325a2c32g3s1000hx.inp 3,992 11-18-2019 00:08 5d8b89b4 ca_ha325a2c32g3s1000hx.out 652,662 11-18-2019 03:17 164c7855 ca_ha325a2c32g3s1100hx.inp 3,992 11-18-2019 00:08 23df814e ca_ha325a2c32g3s1100hx.out 653,712 11-18-2019 03:30 7b9d42c6 ca_ha325a2c32g3s1200hx.inp 3,992 11-18-2019 00:08 952e8d5a ca_ha325a2c32g3s1200hx.out 653,245 11-18-2019 03:18 640bfea8 ca_ha325a2c32g3s1300hx.inp 3,992 11-18-2019 00:08 2a76d149 ca_ha325a2c32g3s1300hx.out 654,215 11-18-2019 03:30 28f39122 ca_ha325a2c32g3s1400hx.inp 3,992 11-18-2019 00:09 502c4a8b ca_ha325a2c32g3s1400hx.out 654,104 11-18-2019 03:20 13e124e1 ca_ha325a2c32g3s1500hx.inp 3,991 11-18-2019 00:09 1a659a71 ca_ha325a2c32g3s1500hx.out 653,463 11-18-2019 03:32 835b2075
\\v1.2\\ca\\hs245\\ (66) 21,158,911 11-20-2019 09:22 ca_hs245a2c32g1s0500hx.inp 4,075 11-18-2019 14:23 c6003b75 ca_hs245a2c32g1s0500hx.out 654,380 11-19-2019 16:48 e7505523 ca_hs245a2c32g1s0600hx.inp 4,076 11-18-2019 14:24 094c700a ca_hs245a2c32g1s0600hx.out 654,439 11-19-2019 16:59 fd7201fa ca_hs245a2c32g1s0700hx.inp 4,076 11-18-2019 14:24 5ca01309 ca_hs245a2c32g1s0700hx.out 654,234 11-19-2019 17:04 a8e92b28 ca_hs245a2c32g1s0800hx.inp 4,076 11-18-2019 14:24 75ac483b ca_hs245a2c32g1s0800hx.out 654,429 11-19-2019 17:00 43bc498b ca_hs245a2c32g1s0900hx.inp 4,076 11-18-2019 14:24 bd438586 ca_hs245a2c32g1s0900hx.out 654,645 11-19-2019 16:55 00c90e68 ca_hs245a2c32g1s1000hx.inp 4,080 11-18-2019 14:24 0e3842ec ca_hs245a2c32g1s1000hx.out 655,047 11-19-2019 16:59 905dd476 ca_hs245a2c32g1s1100hx.inp 4,080 11-18-2019 14:24 1ba14523 ca_hs245a2c32g1s1100hx.out 655,044 11-19-2019 17:01 0d3ec494 ca_hs245a2c32g1s1200hx.inp 4,080 11-18-2019 14:24 fcd67ffc ca_hs245a2c32g1s1200hx.out 654,714 11-19-2019 17:12 ccbdc396 ca_hs245a2c32g1s1300hx.inp 4,080 11-18-2019 14:24 b295398c ca_hs245a2c32g1s1300hx.out 655,684 11-19-2019 17:00 dfa6b19e ca_hs245a2c32g1s1400hx.inp 4,080 11-18-2019 14:24 896ed3ef ca_hs245a2c32g1s1400hx.out 655,022 11-19-2019 17:03 4dc831a6 ca_hs245a2c32g1s1500hx.inp 4,080 11-18-2019 14:24 174c37f4 ca_hs245a2c32g1s1500hx.out 656,133 11-19-2019 17:05 9893693b ca_hs245a2c32g2s0500hx.inp 4,073 11-18-2019 14:24 b9caf8fe ca_hs245a2c32g2s0500hx.out 655,067 11-19-2019 17:44 abf5b1e6 ca_hs245a2c32g2s0600hx.inp 4,074 11-18-2019 14:24 af529516 ca_hs245a2c32g2s0600hx.out 654,913 11-19-2019 17:43 393224e7 ca_hs245a2c32g2s0700hx.inp 4,074 11-18-2019 14:25 ab178da3 ca_hs245a2c32g2s0700hx.out 654,526 11-19-2019 17:39 1e9a29b8 ca_hs245a2c32g2s0800hx.inp 4,074 11-18-2019 14:25 658fe833 ca_hs245a2c32g2s0800hx.out 654,610 11-19-2019 17:39 71a17403 ca_hs245a2c32g2s0900hx.inp 4,074 11-18-2019 14:25 acd78317 ca_hs245a2c32g2s0900hx.out 654,631 11-19-2019 17:40 1ec52f0c ca_hs245a2c32g2s1000hx.inp 4,078 11-18-2019 14:25 1376185d ca_hs245a2c32g2s1000hx.out 654,782 11-19-2019 17:33 71777d07 ca_hs245a2c32g2s1100hx.inp 4,078 11-18-2019 14:25 950bd07e ca_hs245a2c32g2s1100hx.out 654,928 11-19-2019 17:30 a92d8b84 ca_hs245a2c32g2s1200hx.inp 4,078 11-18-2019 14:25 7f8f3325 ca_hs245a2c32g2s1200hx.out 654,969 11-19-2019 17:33 d268bf7d ca_hs245a2c32g2s1300hx.inp 4,078 11-18-2019 14:25 6e47e54c ca_hs245a2c32g2s1300hx.out 655,636 11-19-2019 17:33 9b20a414 ca_hs245a2c32g2s1400hx.inp 4,078 11-18-2019 14:25 305d4d70 ca_hs245a2c32g2s1400hx.out 654,545 11-19-2019 17:35 01065f37 ca_hs245a2c32g2s1500hx.inp 4,078 11-18-2019 14:25 6c4bf900 ca_hs245a2c32g2s1500hx.out 654,937 11-19-2019 17:34 ac380e1d ca_hs245a2c32g3s0500hx.inp 4,070 11-18-2019 14:25 f9bc1394 ca_hs245a2c32g3s0500hx.out 507,913 11-19-2019 17:26 f371407c ca_hs245a2c32g3s0600hx.inp 4,071 11-18-2019 14:25 cebbe2a2 ca_hs245a2c32g3s0600hx.out 507,349 11-19-2019 17:18 5dc78954 ca_hs245a2c32g3s0700hx.inp 4,071 11-18-2019 14:26 d841bb0e ca_hs245a2c32g3s0700hx.out 508,940 11-19-2019 17:27 36dfed21 ca_hs245a2c32g3s0800hx.inp 4,071 11-18-2019 14:26 c4d5f183 ca_hs245a2c32g3s0800hx.out 507,773 11-19-2019 17:34 172f336c ca_hs245a2c32g3s0900hx.inp 4,071 11-18-2019 14:26 0f412313 ca_hs245a2c32g3s0900hx.out 654,481 11-19-2019 17:29 54bf2e04 ca_hs245a2c32g3s1000hx.inp 4,075 11-18-2019 14:26 01173f83 ca_hs245a2c32g3s1000hx.out 654,971 11-19-2019 17:27 09c2ab36 ca_hs245a2c32g3s1100hx.inp 4,075 11-18-2019 14:26 f03db0e9 ca_hs245a2c32g3s1100hx.out 655,516 11-19-2019 17:09 7ca8f433 ca_hs245a2c32g3s1200hx.inp 4,075 11-18-2019 14:26 0d19331c
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
71 of 190 ca_hs245a2c32g3s1200hx.out 655,723 11-19-2019 17:33 924505c6 ca_hs245a2c32g3s1300hx.inp 4,075 11-18-2019 14:26 30310f99 ca_hs245a2c32g3s1300hx.out 653,921 11-19-2019 17:22 c2815f00 ca_hs245a2c32g3s1400hx.inp 4,075 11-18-2019 14:26 7542dcb9 ca_hs245a2c32g3s1400hx.out 654,867 11-19-2019 17:23 659be402 ca_hs245a2c32g3s1500hx.inp 4,075 11-18-2019 14:26 3936eeef ca_hs245a2c32g3s1500hx.out 655,642 11-19-2019 17:29 2bdf1f1f
\\v1.2\\ca\\hs325\\ (66) 21,560,306 11-20-2019 09:22 ca_hs325a2c32g1s0500hx.inp 4,026 11-18-2019 12:36 e23ad17e ca_hs325a2c32g1s0500hx.out 653,546 11-19-2019 11:44 d561efd7 ca_hs325a2c32g1s0600hx.inp 4,026 11-18-2019 12:36 6dc75568 ca_hs325a2c32g1s0600hx.out 653,552 11-19-2019 11:35 beb286f4 ca_hs325a2c32g1s0700hx.inp 4,026 11-18-2019 12:36 4694f5ff ca_hs325a2c32g1s0700hx.out 653,668 11-19-2019 11:35 17991fec ca_hs325a2c32g1s0800hx.inp 4,026 11-18-2019 12:36 b74d2d3a ca_hs325a2c32g1s0800hx.out 654,362 11-19-2019 11:34 e62961ae ca_hs325a2c32g1s0900hx.inp 4,026 11-18-2019 12:36 399bc369 ca_hs325a2c32g1s0900hx.out 653,622 11-19-2019 11:34 ed447901 ca_hs325a2c32g1s1000hx.inp 4,030 11-18-2019 12:36 a8c75354 ca_hs325a2c32g1s1000hx.out 653,567 11-19-2019 11:31 ea935365 ca_hs325a2c32g1s1100hx.inp 4,030 11-18-2019 12:36 b1ff5c28 ca_hs325a2c32g1s1100hx.out 653,623 11-19-2019 11:43 923c3739 ca_hs325a2c32g1s1200hx.inp 4,030 11-18-2019 12:36 c8253718 ca_hs325a2c32g1s1200hx.out 653,957 11-19-2019 11:36 39651c26 ca_hs325a2c32g1s1300hx.inp 4,030 11-18-2019 12:37 7d609f10 ca_hs325a2c32g1s1300hx.out 655,067 11-19-2019 11:40 9a51e628 ca_hs325a2c32g1s1400hx.inp 4,030 11-18-2019 12:37 00a13bdc ca_hs325a2c32g1s1400hx.out 653,624 11-19-2019 11:44 0ebe0fd5 ca_hs325a2c32g1s1500hx.inp 4,029 11-18-2019 12:37 ef841ff8 ca_hs325a2c32g1s1500hx.out 653,735 11-19-2019 11:32 fe9dbfeb ca_hs325a2c32g2s0500hx.inp 4,024 11-18-2019 12:37 f0503ad2 ca_hs325a2c32g2s0500hx.out 654,645 11-19-2019 12:29 0e6e1507 ca_hs325a2c32g2s0600hx.inp 4,024 11-18-2019 12:37 fafbbbd5 ca_hs325a2c32g2s0600hx.out 653,545 11-19-2019 12:27 68f09112 ca_hs325a2c32g2s0700hx.inp 4,024 11-18-2019 12:37 9cae2ac1 ca_hs325a2c32g2s0700hx.out 653,514 11-19-2019 12:15 16996ee6 ca_hs325a2c32g2s0800hx.inp 4,024 11-18-2019 12:37 d12cbf30 ca_hs325a2c32g2s0800hx.out 654,401 11-19-2019 12:26 563e395e ca_hs325a2c32g2s0900hx.inp 4,024 11-18-2019 12:37 2cd9500e ca_hs325a2c32g2s0900hx.out 653,652 11-19-2019 12:00 61a4bd6d ca_hs325a2c32g2s1000hx.inp 4,028 11-18-2019 12:37 75a64c34 ca_hs325a2c32g2s1000hx.out 653,409 11-19-2019 12:18 c13d2890 ca_hs325a2c32g2s1100hx.inp 4,028 11-18-2019 12:37 e2f790e2 ca_hs325a2c32g2s1100hx.out 653,974 11-19-2019 12:12 3eb2d7b9 ca_hs325a2c32g2s1200hx.inp 4,028 11-18-2019 12:37 5467fd7a ca_hs325a2c32g2s1200hx.out 652,888 11-19-2019 12:12 9e7a697b ca_hs325a2c32g2s1300hx.inp 4,028 11-18-2019 12:38 41243f4d ca_hs325a2c32g2s1300hx.out 653,317 11-19-2019 12:22 4e590e5e ca_hs325a2c32g2s1400hx.inp 4,028 11-18-2019 12:38 30ba4996 ca_hs325a2c32g2s1400hx.out 653,347 11-19-2019 12:14 bf4cce8e ca_hs325a2c32g2s1500hx.inp 4,028 11-18-2019 12:38 d84ef80a ca_hs325a2c32g2s1500hx.out 653,423 11-19-2019 12:10 6ae5372e ca_hs325a2c32g3s0500hx.inp 4,021 11-18-2019 12:38 004bd928 ca_hs325a2c32g3s0500hx.out 507,073 11-19-2019 12:06 e32c94d1 ca_hs325a2c32g3s0600hx.inp 4,021 11-18-2019 12:38 d7da5a2c ca_hs325a2c32g3s0600hx.out 653,887 11-19-2019 12:03 3f406eae ca_hs325a2c32g3s0700hx.inp 4,021 11-18-2019 12:38 33338fa9 ca_hs325a2c32g3s0700hx.out 653,898 11-19-2019 11:58 1d55c870 ca_hs325a2c32g3s0800hx.inp 4,021 11-18-2019 12:38 1b734b4c ca_hs325a2c32g3s0800hx.out 654,019 11-19-2019 12:00 7301d2a2 ca_hs325a2c32g3s0900hx.inp 4,021 11-18-2019 12:38 6c3e177d ca_hs325a2c32g3s0900hx.out 653,545 11-19-2019 12:03 a93cc8c4 ca_hs325a2c32g3s1000hx.inp 4,025 11-18-2019 12:38 f78874ab ca_hs325a2c32g3s1000hx.out 654,191 11-19-2019 11:50 7d0cb4b1 ca_hs325a2c32g3s1100hx.inp 4,025 11-18-2019 12:38 e69cae18 ca_hs325a2c32g3s1100hx.out 652,858 11-19-2019 12:01 f09e9f90 ca_hs325a2c32g3s1200hx.inp 4,025 11-18-2019 12:38 5335e69f ca_hs325a2c32g3s1200hx.out 653,137 11-19-2019 12:14 b9749db5 ca_hs325a2c32g3s1300hx.inp 4,025 11-18-2019 12:39 c4f396e1 ca_hs325a2c32g3s1300hx.out 653,916 11-19-2019 12:03 a5dfe119 ca_hs325a2c32g3s1400hx.inp 4,025 11-18-2019 12:39 793f98aa ca_hs325a2c32g3s1400hx.out 653,902 11-19-2019 12:07 33aac29d ca_hs325a2c32g3s1500hx.inp 4,024 11-18-2019 12:39 6eea9203 ca_hs325a2c32g3s1500hx.out 654,591 11-19-2019 12:07 a2b5b8cd
\\v1.2\\ca\\na245\\ (66) 21,741,926 11-20-2019 09:22 ca_na245a2c32g1s0500hx.inp 4,074 11-18-2019 11:13 e7269aab ca_na245a2c32g1s0500hx.out 655,270 11-19-2019 04:00 adf0829a
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
72 of 190 ca_na245a2c32g1s0600hx.inp 4,075 11-18-2019 11:13 a92e399f ca_na245a2c32g1s0600hx.out 655,038 11-19-2019 04:01 3a16b81a ca_na245a2c32g1s0700hx.inp 4,075 11-18-2019 11:13 01ea6eb1 ca_na245a2c32g1s0700hx.out 654,602 11-19-2019 03:58 196eb9d3 ca_na245a2c32g1s0800hx.inp 4,075 11-18-2019 11:13 1eaa4304 ca_na245a2c32g1s0800hx.out 654,412 11-19-2019 04:03 99fa250c ca_na245a2c32g1s0900hx.inp 4,075 11-18-2019 11:13 e0393b04 ca_na245a2c32g1s0900hx.out 654,515 11-19-2019 04:10 462a2975 ca_na245a2c32g1s1000hx.inp 4,079 11-18-2019 11:13 187fc3e5 ca_na245a2c32g1s1000hx.out 654,345 11-19-2019 03:57 89c60e3a ca_na245a2c32g1s1100hx.inp 4,079 11-18-2019 11:13 5e61aaed ca_na245a2c32g1s1100hx.out 654,665 11-19-2019 04:10 3d5f6d3d ca_na245a2c32g1s1200hx.inp 4,079 11-18-2019 11:13 50b82974 ca_na245a2c32g1s1200hx.out 654,414 11-19-2019 03:49 8faaf4db ca_na245a2c32g1s1300hx.inp 4,079 11-18-2019 11:13 8859ff9b ca_na245a2c32g1s1300hx.out 654,315 11-19-2019 04:01 caa333c1 ca_na245a2c32g1s1400hx.inp 4,079 11-18-2019 11:13 7516953c ca_na245a2c32g1s1400hx.out 655,676 11-19-2019 04:05 55059843 ca_na245a2c32g1s1500hx.inp 4,079 11-18-2019 11:14 fc19e2c8 ca_na245a2c32g1s1500hx.out 654,585 11-19-2019 04:12 e04adcbf ca_na245a2c32g2s0500hx.inp 4,072 11-18-2019 11:14 e92228f3 ca_na245a2c32g2s0500hx.out 654,907 11-19-2019 04:51 6f87020a ca_na245a2c32g2s0600hx.inp 4,073 11-18-2019 11:14 15b1cbde ca_na245a2c32g2s0600hx.out 653,567 11-19-2019 04:38 1cf7d382 ca_na245a2c32g2s0700hx.inp 4,073 11-18-2019 11:14 fef8b751 ca_na245a2c32g2s0700hx.out 654,342 11-19-2019 04:38 d5225572 ca_na245a2c32g2s0800hx.inp 4,073 11-18-2019 11:14 8a0558b7 ca_na245a2c32g2s0800hx.out 655,826 11-19-2019 04:35 53f625df ca_na245a2c32g2s0900hx.inp 4,073 11-18-2019 11:14 b8dbe2ca ca_na245a2c32g2s0900hx.out 655,195 11-19-2019 04:44 59dc0d8e ca_na245a2c32g2s1000hx.inp 4,077 11-18-2019 11:14 84c00cb1 ca_na245a2c32g2s1000hx.out 654,504 11-19-2019 04:35 8589deda ca_na245a2c32g2s1100hx.inp 4,077 11-18-2019 11:14 6a0e89e1 ca_na245a2c32g2s1100hx.out 654,839 11-19-2019 04:30 e5b45d63 ca_na245a2c32g2s1200hx.inp 4,077 11-18-2019 11:14 8b0d6c24 ca_na245a2c32g2s1200hx.out 654,703 11-19-2019 04:34 0d35108d ca_na245a2c32g2s1300hx.inp 4,077 11-18-2019 11:14 80061252 ca_na245a2c32g2s1300hx.out 654,854 11-19-2019 04:35 8f97f672 ca_na245a2c32g2s1400hx.inp 4,077 11-18-2019 11:14 813163f1 ca_na245a2c32g2s1400hx.out 654,709 11-19-2019 04:33 4af443c3 ca_na245a2c32g2s1500hx.inp 4,077 11-18-2019 11:15 763983b1 ca_na245a2c32g2s1500hx.out 655,122 11-19-2019 04:37 58c06a9f ca_na245a2c32g3s0500hx.inp 4,069 11-18-2019 11:15 73b27194 ca_na245a2c32g3s0500hx.out 655,261 11-19-2019 04:25 23dab269 ca_na245a2c32g3s0600hx.inp 4,070 11-18-2019 11:15 655f5635 ca_na245a2c32g3s0600hx.out 654,944 11-19-2019 04:29 fd1b874c ca_na245a2c32g3s0700hx.inp 4,070 11-18-2019 11:15 f6707d21 ca_na245a2c32g3s0700hx.out 654,181 11-19-2019 04:25 feb0845d ca_na245a2c32g3s0800hx.inp 4,070 11-18-2019 11:15 a55f28bc ca_na245a2c32g3s0800hx.out 654,739 11-19-2019 04:29 0b12b5d1 ca_na245a2c32g3s0900hx.inp 4,070 11-18-2019 11:15 7335e826 ca_na245a2c32g3s0900hx.out 655,552 11-19-2019 04:19 773b04e6 ca_na245a2c32g3s1000hx.inp 4,074 11-18-2019 11:15 372ea7e6 ca_na245a2c32g3s1000hx.out 654,788 11-19-2019 04:19 c02eff3a ca_na245a2c32g3s1100hx.inp 4,074 11-18-2019 11:15 b577cdf8 ca_na245a2c32g3s1100hx.out 655,044 11-19-2019 04:19 a3bbc3f1 ca_na245a2c32g3s1200hx.inp 4,074 11-18-2019 11:15 94a645a0 ca_na245a2c32g3s1200hx.out 654,222 11-19-2019 04:27 b1803db6 ca_na245a2c32g3s1300hx.inp 4,074 11-18-2019 11:15 14c513e4 ca_na245a2c32g3s1300hx.out 654,938 11-19-2019 04:28 4088d6bb ca_na245a2c32g3s1400hx.inp 4,074 11-18-2019 11:15 0bc1db3e ca_na245a2c32g3s1400hx.out 654,349 11-19-2019 04:23 668617f9 ca_na245a2c32g3s1500hx.inp 4,074 11-18-2019 11:16 da8b40a7 ca_na245a2c32g3s1500hx.out 655,036 11-19-2019 04:29 e0ccc5ec
\\v1.2\\ca\\na325\\ (66) 21,706,604 11-20-2019 09:22 ca_na325a2c32g1s0500hx.inp 4,025 11-18-2019 10:11 5ae68da3 ca_na325a2c32g1s0500hx.out 654,316 11-18-2019 20:03 f7134c47 ca_na325a2c32g1s0600hx.inp 4,025 11-18-2019 10:11 75cea084 ca_na325a2c32g1s0600hx.out 653,810 11-18-2019 20:05 0497411d ca_na325a2c32g1s0700hx.inp 4,025 11-18-2019 10:11 ab9ea566 ca_na325a2c32g1s0700hx.out 653,775 11-18-2019 19:53 329b1110 ca_na325a2c32g1s0800hx.inp 4,025 11-18-2019 10:11 9a4e5c79 ca_na325a2c32g1s0800hx.out 654,231 11-18-2019 19:53 b3f0c0fc ca_na325a2c32g1s0900hx.inp 4,025 11-18-2019 10:11 9ae5def7 ca_na325a2c32g1s0900hx.out 653,732 11-18-2019 19:53 32d318d4 ca_na325a2c32g1s1000hx.inp 4,029 11-18-2019 10:11 5f1037a7 ca_na325a2c32g1s1000hx.out 653,959 11-18-2019 19:52 5b6026a3 ca_na325a2c32g1s1100hx.inp 4,029 11-18-2019 10:11 58f246a1 ca_na325a2c32g1s1100hx.out 653,778 11-18-2019 20:08 3055eb94
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
73 of 190 ca_na325a2c32g1s1200hx.inp 4,029 11-18-2019 10:11 788f4322 ca_na325a2c32g1s1200hx.out 653,126 11-18-2019 20:05 e56a8900 ca_na325a2c32g1s1300hx.inp 4,029 11-18-2019 10:11 20793e39 ca_na325a2c32g1s1300hx.out 653,607 11-18-2019 19:53 9b4bac89 ca_na325a2c32g1s1400hx.inp 4,029 11-18-2019 10:11 18be8396 ca_na325a2c32g1s1400hx.out 654,000 11-18-2019 19:53 6f519309 ca_na325a2c32g1s1500hx.inp 4,028 11-18-2019 10:12 50bc4723 ca_na325a2c32g1s1500hx.out 654,072 11-18-2019 19:55 4991058e ca_na325a2c32g2s0500hx.inp 4,023 11-18-2019 10:12 63c902df ca_na325a2c32g2s0500hx.out 653,348 11-18-2019 21:00 328830c4 ca_na325a2c32g2s0600hx.inp 4,023 11-18-2019 10:12 daa5eafd ca_na325a2c32g2s0600hx.out 652,756 11-18-2019 20:58 4149e5e5 ca_na325a2c32g2s0700hx.inp 4,023 11-18-2019 10:12 cd418a7d ca_na325a2c32g2s0700hx.out 652,773 11-18-2019 20:58 dac947d3 ca_na325a2c32g2s0800hx.inp 4,023 11-18-2019 10:12 cdba167f ca_na325a2c32g2s0800hx.out 653,691 11-18-2019 21:02 88f529e8 ca_na325a2c32g2s0900hx.inp 4,023 11-18-2019 10:12 61afb862 ca_na325a2c32g2s0900hx.out 654,259 11-18-2019 20:38 715be6ac ca_na325a2c32g2s1000hx.inp 4,027 11-18-2019 10:12 cc4719b5 ca_na325a2c32g2s1000hx.out 654,082 11-18-2019 20:51 33c66743 ca_na325a2c32g2s1100hx.inp 4,027 11-18-2019 10:12 5df98622 ca_na325a2c32g2s1100hx.out 653,416 11-18-2019 20:45 970efdbf ca_na325a2c32g2s1200hx.inp 4,027 11-18-2019 10:12 9961632c ca_na325a2c32g2s1200hx.out 653,651 11-18-2019 20:34 f8b5aafb ca_na325a2c32g2s1300hx.inp 4,027 11-18-2019 10:12 9cd643c8 ca_na325a2c32g2s1300hx.out 654,093 11-18-2019 20:50 7255453e ca_na325a2c32g2s1400hx.inp 4,027 11-18-2019 10:12 9f559294 ca_na325a2c32g2s1400hx.out 653,679 11-18-2019 20:37 fa74da10 ca_na325a2c32g2s1500hx.inp 4,027 11-18-2019 10:12 9afc7914 ca_na325a2c32g2s1500hx.out 653,661 11-18-2019 20:37 f2b5c8b4 ca_na325a2c32g3s0500hx.inp 4,020 11-18-2019 10:13 f40fbc65 ca_na325a2c32g3s0500hx.out 654,076 11-18-2019 20:44 96917345 ca_na325a2c32g3s0600hx.inp 4,020 11-18-2019 10:13 c94803c0 ca_na325a2c32g3s0600hx.out 653,281 11-18-2019 20:44 d444d49f ca_na325a2c32g3s0700hx.inp 4,020 11-18-2019 10:13 a7e56ab3 ca_na325a2c32g3s0700hx.out 654,118 11-18-2019 20:20 0d21e119 ca_na325a2c32g3s0800hx.inp 4,020 11-18-2019 10:13 d442fe34 ca_na325a2c32g3s0800hx.out 653,849 11-18-2019 20:22 43c77c21 ca_na325a2c32g3s0900hx.inp 4,020 11-18-2019 10:13 1a9a04cb ca_na325a2c32g3s0900hx.out 653,115 11-18-2019 20:42 43ff598f ca_na325a2c32g3s1000hx.inp 4,024 11-18-2019 10:13 b3e7625b ca_na325a2c32g3s1000hx.out 653,942 11-18-2019 20:30 354f029f ca_na325a2c32g3s1100hx.inp 4,024 11-18-2019 10:13 286d1d78 ca_na325a2c32g3s1100hx.out 654,296 11-18-2019 20:30 01997a16 ca_na325a2c32g3s1200hx.inp 4,024 11-18-2019 10:13 d7b1131f ca_na325a2c32g3s1200hx.out 654,184 11-18-2019 20:36 8533d413 ca_na325a2c32g3s1300hx.inp 4,024 11-18-2019 10:13 bed92b31 ca_na325a2c32g3s1300hx.out 653,671 11-18-2019 20:48 1a5c42a7 ca_na325a2c32g3s1400hx.inp 4,024 11-18-2019 10:13 4eb583a0 ca_na325a2c32g3s1400hx.out 653,573 11-18-2019 20:41 e280deba ca_na325a2c32g3s1500hx.inp 4,023 11-18-2019 10:13 2b5a5236 ca_na325a2c32g3s1500hx.out 653,866 11-18-2019 20:43 8c885080
\\v1.2\\ca\\ns245\\ (66) 20,859,545 11-20-2019 09:22 ca_ns245a2c32g1s0500hx.inp 4,075 11-18-2019 16:55 fb5e2824 ca_ns245a2c32g1s0500hx.out 653,895 11-20-2019 03:14 8a12025b ca_ns245a2c32g1s0600hx.inp 4,076 11-18-2019 16:55 27f442d4 ca_ns245a2c32g1s0600hx.out 654,100 11-20-2019 03:10 9b6a04b7 ca_ns245a2c32g1s0700hx.inp 4,076 11-18-2019 16:55 721821d7 ca_ns245a2c32g1s0700hx.out 655,328 11-20-2019 03:13 169fa33e ca_ns245a2c32g1s0800hx.inp 4,076 11-18-2019 16:55 5b147ae5 ca_ns245a2c32g1s0800hx.out 654,157 11-20-2019 03:12 06a6ea1c ca_ns245a2c32g1s0900hx.inp 4,076 11-18-2019 16:55 93fbb758 ca_ns245a2c32g1s0900hx.out 655,620 11-20-2019 03:20 53921f60 ca_ns245a2c32g1s1000hx.inp 4,080 11-18-2019 16:55 816c86ba ca_ns245a2c32g1s1000hx.out 654,731 11-20-2019 03:11 ffdd6928 ca_ns245a2c32g1s1100hx.inp 4,080 11-18-2019 16:56 94f58175 ca_ns245a2c32g1s1100hx.out 653,782 11-20-2019 03:13 88e23ba8 ca_ns245a2c32g1s1200hx.inp 4,080 11-18-2019 16:56 7382bbaa ca_ns245a2c32g1s1200hx.out 654,763 11-20-2019 03:18 9a226bfa ca_ns245a2c32g1s1300hx.inp 4,080 11-18-2019 16:56 3dc1fdda ca_ns245a2c32g1s1300hx.out 654,948 11-20-2019 03:24 fd1e6854 ca_ns245a2c32g1s1400hx.inp 4,080 11-18-2019 16:56 063a17b9 ca_ns245a2c32g1s1400hx.out 655,157 11-20-2019 03:16 4607dc1f ca_ns245a2c32g1s1500hx.inp 4,080 11-18-2019 16:56 9818f3a2 ca_ns245a2c32g1s1500hx.out 654,863 11-20-2019 03:21 4346d57e ca_ns245a2c32g2s0500hx.inp 4,073 11-18-2019 16:56 d23dc6ac ca_ns245a2c32g2s0500hx.out 653,769 11-20-2019 04:09 1a789158 ca_ns245a2c32g2s0600hx.inp 4,074 11-18-2019 16:56 18b55f5f ca_ns245a2c32g2s0600hx.out 654,704 11-20-2019 03:59 8d52e68e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
74 of 190 ca_ns245a2c32g2s0700hx.inp 4,074 11-18-2019 16:56 1cf047ea ca_ns245a2c32g2s0700hx.out 654,360 11-20-2019 03:53 e389114c ca_ns245a2c32g2s0800hx.inp 4,074 11-18-2019 16:56 d268227a ca_ns245a2c32g2s0800hx.out 654,795 11-20-2019 03:53 1008f45a ca_ns245a2c32g2s0900hx.inp 4,074 11-18-2019 16:56 1b30495e ca_ns245a2c32g2s0900hx.out 655,150 11-20-2019 04:04 4f4ddba2 ca_ns245a2c32g2s1000hx.inp 4,078 11-18-2019 16:56 19f2a471 ca_ns245a2c32g2s1000hx.out 654,590 11-20-2019 03:58 83381dd2 ca_ns245a2c32g2s1100hx.inp 4,078 11-18-2019 16:57 9f8f6c52 ca_ns245a2c32g2s1100hx.out 654,660 11-20-2019 03:54 fb61a248 ca_ns245a2c32g2s1200hx.inp 4,078 11-18-2019 16:57 750b8f09 ca_ns245a2c32g2s1200hx.out 654,868 11-20-2019 03:59 267e62ba ca_ns245a2c32g2s1300hx.inp 4,078 11-18-2019 16:57 64c35960 ca_ns245a2c32g2s1300hx.out 654,876 11-20-2019 03:54 78761e9c ca_ns245a2c32g2s1400hx.inp 4,078 11-18-2019 16:57 3ad9f15c ca_ns245a2c32g2s1400hx.out 655,142 11-20-2019 03:55 d8fdcc6b ca_ns245a2c32g2s1500hx.inp 4,078 11-18-2019 16:57 66cf452c ca_ns245a2c32g2s1500hx.out 654,742 11-20-2019 03:54 efd8e8da ca_ns245a2c32g3s0500hx.inp 4,070 11-18-2019 16:57 a3e70885 ca_ns245a2c32g3s0500hx.out 507,444 11-20-2019 03:45 8b984e36 ca_ns245a2c32g3s0600hx.inp 4,071 11-18-2019 16:57 96b894e4 ca_ns245a2c32g3s0600hx.out 507,801 11-20-2019 03:47 194d925c ca_ns245a2c32g3s0700hx.inp 4,071 11-18-2019 16:57 8042cd48 ca_ns245a2c32g3s0700hx.out 508,729 11-20-2019 03:44 7cc8701e ca_ns245a2c32g3s0800hx.inp 4,071 11-18-2019 16:57 9cd687c5 ca_ns245a2c32g3s0800hx.out 507,332 11-20-2019 03:56 c83016af ca_ns245a2c32g3s0900hx.inp 4,071 11-18-2019 16:57 57425555 ca_ns245a2c32g3s0900hx.out 508,082 11-20-2019 03:43 8732892d ca_ns245a2c32g3s1000hx.inp 4,075 11-18-2019 16:57 0b277963 ca_ns245a2c32g3s1000hx.out 508,716 11-20-2019 03:54 0fe6193b ca_ns245a2c32g3s1100hx.inp 4,075 11-18-2019 16:58 fa0df609 ca_ns245a2c32g3s1100hx.out 654,611 11-20-2019 03:57 3d19bdd7 ca_ns245a2c32g3s1200hx.inp 4,075 11-18-2019 16:58 072975fc ca_ns245a2c32g3s1200hx.out 655,507 11-20-2019 03:45 c0552367 ca_ns245a2c32g3s1300hx.inp 4,075 11-18-2019 16:58 3a014979 ca_ns245a2c32g3s1300hx.out 655,059 11-20-2019 03:46 a1a6fc35 ca_ns245a2c32g3s1400hx.inp 4,075 11-18-2019 16:58 7f729a59 ca_ns245a2c32g3s1400hx.out 654,883 11-20-2019 03:35 2b38051c ca_ns245a2c32g3s1500hx.inp 4,075 11-18-2019 16:58 3306a80f ca_ns245a2c32g3s1500hx.out 653,881 11-20-2019 03:54 1825e539
\\v1.2\\ca\\ns325\\ (66) 21,413,477 11-20-2019 09:22 ca_ns325a2c32g1s0500hx.inp 4,026 11-18-2019 15:51 fb2a05fb ca_ns325a2c32g1s0500hx.out 653,370 11-19-2019 22:07 7baa4f18 ca_ns325a2c32g1s0600hx.inp 4,026 11-18-2019 15:51 74d781ed ca_ns325a2c32g1s0600hx.out 652,854 11-19-2019 22:03 90386e0b ca_ns325a2c32g1s0700hx.inp 4,026 11-18-2019 15:51 5f84217a ca_ns325a2c32g1s0700hx.out 652,294 11-19-2019 22:15 62e448a1 ca_ns325a2c32g1s0800hx.inp 4,026 11-18-2019 15:51 ae5df9bf ca_ns325a2c32g1s0800hx.out 654,610 11-19-2019 22:05 38e2d3b5 ca_ns325a2c32g1s0900hx.inp 4,026 11-18-2019 15:51 208b17ec ca_ns325a2c32g1s0900hx.out 654,231 11-19-2019 22:21 79115da9 ca_ns325a2c32g1s1000hx.inp 4,030 11-18-2019 15:51 c1d01e69 ca_ns325a2c32g1s1000hx.out 653,427 11-19-2019 22:13 bcc8326a ca_ns325a2c32g1s1100hx.inp 4,030 11-18-2019 15:51 d8e81115 ca_ns325a2c32g1s1100hx.out 653,625 11-19-2019 22:10 af830f6a ca_ns325a2c32g1s1200hx.inp 4,030 11-18-2019 15:51 a1327a25 ca_ns325a2c32g1s1200hx.out 654,110 11-19-2019 22:18 03c912b9 ca_ns325a2c32g1s1300hx.inp 4,030 11-18-2019 15:51 1477d22d ca_ns325a2c32g1s1300hx.out 653,130 11-19-2019 22:13 c6d71cf7 ca_ns325a2c32g1s1400hx.inp 4,030 11-18-2019 15:51 69b676e1 ca_ns325a2c32g1s1400hx.out 653,497 11-19-2019 22:07 dff46325 ca_ns325a2c32g1s1500hx.inp 4,029 11-18-2019 15:52 cf6a9047 ca_ns325a2c32g1s1500hx.out 653,684 11-19-2019 22:28 264d1c6e ca_ns325a2c32g2s0500hx.inp 4,024 11-18-2019 15:52 f0e8949e ca_ns325a2c32g2s0500hx.out 654,036 11-19-2019 23:02 5ac69702 ca_ns325a2c32g2s0600hx.inp 4,024 11-18-2019 15:52 fa431599 ca_ns325a2c32g2s0600hx.out 653,336 11-19-2019 22:53 c572f4e8 ca_ns325a2c32g2s0700hx.inp 4,024 11-18-2019 15:52 9c16848d ca_ns325a2c32g2s0700hx.out 653,369 11-19-2019 23:02 557f3dfd ca_ns325a2c32g2s0800hx.inp 4,024 11-18-2019 15:52 d194117c ca_ns325a2c32g2s0800hx.out 654,340 11-19-2019 23:02 83f59875 ca_ns325a2c32g2s0900hx.inp 4,024 11-18-2019 15:52 2c61fe42 ca_ns325a2c32g2s0900hx.out 653,494 11-19-2019 22:59 815dfaa5 ca_ns325a2c32g2s1000hx.inp 4,028 11-18-2019 15:52 c5cd0c6d ca_ns325a2c32g2s1000hx.out 654,578 11-19-2019 23:01 a6517d36 ca_ns325a2c32g2s1100hx.inp 4,028 11-18-2019 15:52 529cd0bb ca_ns325a2c32g2s1100hx.out 653,347 11-19-2019 22:50 76d57259 ca_ns325a2c32g2s1200hx.inp 4,028 11-18-2019 15:52 e40cbd23 ca_ns325a2c32g2s1200hx.out 654,219 11-19-2019 22:39 cb49551b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
75 of 190 ca_ns325a2c32g2s1300hx.inp 4,028 11-18-2019 15:52 f14f7f14 ca_ns325a2c32g2s1300hx.out 654,729 11-19-2019 23:04 4293f06b ca_ns325a2c32g2s1400hx.inp 4,028 11-18-2019 15:52 80d109cf ca_ns325a2c32g2s1400hx.out 654,038 11-19-2019 22:39 851c05f0 ca_ns325a2c32g2s1500hx.inp 4,028 11-18-2019 15:52 6825b853 ca_ns325a2c32g2s1500hx.out 653,437 11-19-2019 22:54 52dcc52a ca_ns325a2c32g3s0500hx.inp 4,021 11-18-2019 15:53 7945adfb ca_ns325a2c32g3s0500hx.out 507,110 11-19-2019 22:54 de0fd584 ca_ns325a2c32g3s0600hx.inp 4,021 11-18-2019 15:53 aed42eff ca_ns325a2c32g3s0600hx.out 506,878 11-19-2019 22:46 c2e94339 ca_ns325a2c32g3s0700hx.inp 4,021 11-18-2019 15:53 4a3dfb7a ca_ns325a2c32g3s0700hx.out 654,292 11-19-2019 22:33 58f57d30 ca_ns325a2c32g3s0800hx.inp 4,021 11-18-2019 15:53 627d3f9f ca_ns325a2c32g3s0800hx.out 653,693 11-19-2019 22:43 fcc92942 ca_ns325a2c32g3s0900hx.inp 4,021 11-18-2019 15:53 153063ae ca_ns325a2c32g3s0900hx.out 652,884 11-19-2019 22:43 abfb4139 ca_ns325a2c32g3s1000hx.inp 4,025 11-18-2019 15:53 e19c2f07 ca_ns325a2c32g3s1000hx.out 654,884 11-19-2019 22:45 65a7a672 ca_ns325a2c32g3s1100hx.inp 4,025 11-18-2019 15:53 f088f5b4 ca_ns325a2c32g3s1100hx.out 653,856 11-19-2019 22:45 9d858d2b ca_ns325a2c32g3s1200hx.inp 4,025 11-18-2019 15:53 4521bd33 ca_ns325a2c32g3s1200hx.out 653,968 11-19-2019 22:43 142c6387 ca_ns325a2c32g3s1300hx.inp 4,025 11-18-2019 15:53 d2e7cd4d ca_ns325a2c32g3s1300hx.out 653,716 11-19-2019 22:44 91262f09 ca_ns325a2c32g3s1400hx.inp 4,025 11-18-2019 15:53 6f2bc306 ca_ns325a2c32g3s1400hx.out 653,510 11-19-2019 22:47 b65f73b4 ca_ns325a2c32g3s1500hx.inp 4,024 11-18-2019 15:53 271f37f0 ca_ns325a2c32g3s1500hx.out 654,080 11-19-2019 22:51 21fe57aa
\\v1.2\\cb\\ (0) 45,642,229 11-18-2019 16:58
\\v1.2\\cb\\ha245\\ (22) 5,619,006 11-18-2019 20:33 cb_ha245b2c32g0s0500hx.inp 4,117 11-18-2019 02:02 53a4b7a9 cb_ha245b2c32g0s0500hx.out 507,263 11-18-2019 13:24 2a1d34b7 cb_ha245b2c32g0s0600hx.inp 4,118 11-18-2019 02:02 5aa8f74f cb_ha245b2c32g0s0600hx.out 506,645 11-18-2019 13:22 c62f1555 cb_ha245b2c32g0s0700hx.inp 4,118 11-18-2019 02:02 f19ebc1c cb_ha245b2c32g0s0700hx.out 506,573 11-18-2019 13:20 aa09f82e cb_ha245b2c32g0s0800hx.inp 4,118 11-18-2019 02:02 a089e2b8 cb_ha245b2c32g0s0800hx.out 506,374 11-18-2019 13:21 a43f62a5 cb_ha245b2c32g0s0900hx.inp 4,118 11-18-2019 02:02 568eda0d cb_ha245b2c32g0s0900hx.out 506,900 11-18-2019 13:19 d2031485 cb_ha245b2c32g0s1000hx.inp 4,122 11-18-2019 02:02 4ab13d84 cb_ha245b2c32g0s1000hx.out 506,063 11-18-2019 13:19 56eda06f cb_ha245b2c32g0s1100hx.inp 4,122 11-18-2019 02:02 c7e044b6 cb_ha245b2c32g0s1100hx.out 506,752 11-18-2019 13:21 761e8da3 cb_ha245b2c32g0s1200hx.inp 4,122 11-18-2019 02:02 b8b32ca4 cb_ha245b2c32g0s1200hx.out 506,292 11-18-2019 13:21 3df1af72 cb_ha245b2c32g0s1300hx.inp 4,122 11-18-2019 02:02 81c9b2ea cb_ha245b2c32g0s1300hx.out 507,032 11-18-2019 13:19 9783032f cb_ha245b2c32g0s1400hx.inp 4,122 11-18-2019 02:03 1ef6bc34 cb_ha245b2c32g0s1400hx.out 507,149 11-18-2019 13:20 fabc7072 cb_ha245b2c32g0s1500hx.inp 4,122 11-18-2019 02:03 a143c89d cb_ha245b2c32g0s1500hx.out 506,642 11-18-2019 13:21 807d1ab5
\\v1.2\\cb\\ha325\\ (22) 6,337,014 11-18-2019 20:33 cb_ha325b2c32g0s0500hx.inp 4,063 11-18-2019 00:09 76f223e8 cb_ha325b2c32g0s0500hx.out 504,910 11-18-2019 04:00 0774cf1b cb_ha325b2c32g0s0600hx.inp 4,063 11-18-2019 00:09 a6f98ca6 cb_ha325b2c32g0s0600hx.out 505,675 11-18-2019 03:58 64970a0a cb_ha325b2c32g0s0700hx.inp 4,063 11-18-2019 00:09 8bc20d95 cb_ha325b2c32g0s0700hx.out 505,563 11-18-2019 03:56 33884aa9 cb_ha325b2c32g0s0800hx.inp 4,063 11-18-2019 00:09 f1c5f263 cb_ha325b2c32g0s0800hx.out 505,462 11-18-2019 03:52 97bb0997 cb_ha325b2c32g0s0900hx.inp 4,063 11-18-2019 00:09 dd4e3682 cb_ha325b2c32g0s0900hx.out 505,352 11-18-2019 03:49 f9e78a76 cb_ha325b2c32g0s1000hx.inp 4,067 11-18-2019 00:09 4faa46b0 cb_ha325b2c32g0s1000hx.out 506,088 11-18-2019 03:49 5966b218 cb_ha325b2c32g0s1100hx.inp 4,067 11-18-2019 00:09 9a200831 cb_ha325b2c32g0s1100hx.out 651,580 11-18-2019 03:51 b220aa8d cb_ha325b2c32g0s1200hx.inp 4,067 11-18-2019 00:09 b7533f45 cb_ha325b2c32g0s1200hx.out 651,563 11-18-2019 03:51 3a2963b7 cb_ha325b2c32g0s1300hx.inp 4,067 11-18-2019 00:09 bf63b7f2 cb_ha325b2c32g0s1300hx.out 651,983 11-18-2019 03:52 b13782ba cb_ha325b2c32g0s1400hx.inp 4,067 11-18-2019 00:10 37e7c8dc cb_ha325b2c32g0s1400hx.out 651,741 11-18-2019 03:52 a5165e8f cb_ha325b2c32g0s1500hx.inp 4,067 11-18-2019 00:10 eb841575 cb_ha325b2c32g0s1500hx.out 652,380 11-18-2019 03:49 03ef28a4
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
76 of 190
\\v1.2\\cb\\hs245\\ (22) 5,619,729 11-20-2019 09:22 cb_hs245b2c32g0s0500hx.inp 4,145 11-18-2019 14:26 2cb4dedf cb_hs245b2c32g0s0500hx.out 506,594 11-19-2019 17:27 d12048e4 cb_hs245b2c32g0s0600hx.inp 4,146 11-18-2019 14:26 6bd94b65 cb_hs245b2c32g0s0600hx.out 506,906 11-19-2019 17:45 4ad39620 cb_hs245b2c32g0s0700hx.inp 4,146 11-18-2019 14:27 06dd374b cb_hs245b2c32g0s0700hx.out 505,851 11-19-2019 17:44 d4fdc1ca cb_hs245b2c32g0s0800hx.inp 4,146 11-18-2019 14:27 e6fe32a3 cb_hs245b2c32g0s0800hx.out 506,872 11-19-2019 17:34 6d5dae1b cb_hs245b2c32g0s0900hx.inp 4,146 11-18-2019 14:27 6dfdea6a cb_hs245b2c32g0s0900hx.out 506,689 11-19-2019 17:34 9bee17b6 cb_hs245b2c32g0s1000hx.inp 4,150 11-18-2019 14:27 2c4afac0 cb_hs245b2c32g0s1000hx.out 506,559 11-19-2019 17:35 0260f711 cb_hs245b2c32g0s1100hx.inp 4,150 11-18-2019 14:27 a8cf0a34 cb_hs245b2c32g0s1100hx.out 506,675 11-19-2019 17:33 0d838d16 cb_hs245b2c32g0s1200hx.inp 4,150 11-18-2019 14:27 888c3924 cb_hs245b2c32g0s1200hx.out 506,900 11-19-2019 17:51 ef322094 cb_hs245b2c32g0s1300hx.inp 4,150 11-18-2019 14:27 5243d40d cb_hs245b2c32g0s1300hx.out 507,493 11-19-2019 17:38 fe937165 cb_hs245b2c32g0s1400hx.inp 4,150 11-18-2019 14:27 b6c9e420 cb_hs245b2c32g0s1400hx.out 507,177 11-19-2019 17:39 210806d4 cb_hs245b2c32g0s1500hx.inp 4,150 11-18-2019 14:27 350535b1 cb_hs245b2c32g0s1500hx.out 506,384 11-19-2019 17:43 f2e7cc2b
\\v1.2\\cb\\hs325\\ (22) 5,608,819 11-20-2019 09:22 cb_hs325b2c32g0s0500hx.inp 4,096 11-18-2019 12:39 13cdae62 cb_hs325b2c32g0s0500hx.out 504,992 11-19-2019 12:19 f7a8863c cb_hs325b2c32g0s0600hx.inp 4,096 11-18-2019 12:39 1a86e094 cb_hs325b2c32g0s0600hx.out 505,540 11-19-2019 12:14 1805864d cb_hs325b2c32g0s0700hx.inp 4,096 11-18-2019 12:39 6c12ee28 cb_hs325b2c32g0s0700hx.out 506,888 11-19-2019 12:35 5d55ac14 cb_hs325b2c32g0s0800hx.inp 4,096 11-18-2019 12:39 3b6a7b3d cb_hs325b2c32g0s0800hx.out 505,787 11-19-2019 12:02 65c909aa cb_hs325b2c32g0s0900hx.inp 4,096 11-18-2019 12:39 3d73d819 cb_hs325b2c32g0s0900hx.out 505,792 11-19-2019 12:14 f8e635dc cb_hs325b2c32g0s1000hx.inp 4,100 11-18-2019 12:39 80691d46 cb_hs325b2c32g0s1000hx.out 505,577 11-19-2019 12:08 d31dcb54 cb_hs325b2c32g0s1100hx.inp 4,100 11-18-2019 12:39 9e5c9fc2 cb_hs325b2c32g0s1100hx.out 505,310 11-19-2019 12:20 640c7f27 cb_hs325b2c32g0s1200hx.inp 4,100 11-18-2019 12:39 b996d154 cb_hs325b2c32g0s1200hx.out 505,584 11-19-2019 12:37 3b59e0d3 cb_hs325b2c32g0s1300hx.inp 4,100 11-18-2019 12:39 03806987 cb_hs325b2c32g0s1300hx.out 506,074 11-19-2019 12:23 b2d8017e cb_hs325b2c32g0s1400hx.inp 4,100 11-18-2019 12:40 a21938fa cb_hs325b2c32g0s1400hx.out 506,230 11-19-2019 12:23 6aaf8663 cb_hs325b2c32g0s1500hx.inp 4,100 11-18-2019 12:40 464d5b6f cb_hs325b2c32g0s1500hx.out 505,965 11-19-2019 12:24 fc3dbe22
\\v1.2\\cb\\na245\\ (22) 5,619,208 11-20-2019 09:22 cb_na245b2c32g0s0500hx.inp 4,144 11-18-2019 11:16 5e82b258 cb_na245b2c32g0s0500hx.out 506,606 11-19-2019 04:53 ca1d80a3 cb_na245b2c32g0s0600hx.inp 4,145 11-18-2019 11:16 bf3c7d93 cb_na245b2c32g0s0600hx.out 507,583 11-19-2019 04:41 bdda5541 cb_na245b2c32g0s0700hx.inp 4,145 11-18-2019 11:16 dd2d6e58 cb_na245b2c32g0s0700hx.out 506,475 11-19-2019 04:30 ff96e102 cb_na245b2c32g0s0800hx.inp 4,145 11-18-2019 11:16 ffb10a45 cb_na245b2c32g0s0800hx.out 505,942 11-19-2019 04:42 ba41d41d cb_na245b2c32g0s0900hx.inp 4,145 11-18-2019 11:16 8569fd2f cb_na245b2c32g0s0900hx.out 506,808 11-19-2019 04:37 9ae4eb8b cb_na245b2c32g0s1000hx.inp 4,149 11-18-2019 11:16 62698646 cb_na245b2c32g0s1000hx.out 506,292 11-19-2019 04:38 96d1ae71 cb_na245b2c32g0s1100hx.inp 4,149 11-18-2019 11:16 16996126 cb_na245b2c32g0s1100hx.out 506,827 11-19-2019 04:32 a3493ce3 cb_na245b2c32g0s1200hx.inp 4,149 11-18-2019 11:16 680af0fb cb_na245b2c32g0s1200hx.out 506,533 11-19-2019 04:42 1d4a410f cb_na245b2c32g0s1300hx.inp 4,149 11-18-2019 11:16 cece00f3 cb_na245b2c32g0s1300hx.out 506,758 11-19-2019 04:34 25832340 cb_na245b2c32g0s1400hx.inp 4,149 11-18-2019 11:16 019de306 cb_na245b2c32g0s1400hx.out 506,953 11-19-2019 04:35 db862c6a cb_na245b2c32g0s1500hx.inp 4,149 11-18-2019 11:16 cd7465da cb_na245b2c32g0s1500hx.out 506,813 11-19-2019 04:25 ae36808f
\\v1.2\\cb\\na325\\ (22) 5,609,405 11-20-2019 09:22 cb_na325b2c32g0s0500hx.inp 4,095 11-18-2019 10:14 f2a78f87 cb_na325b2c32g0s0500hx.out 506,867 11-18-2019 20:59 e31136fd cb_na325b2c32g0s0600hx.inp 4,095 11-18-2019 10:14 ea7112ca
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
77 of 190 cb_na325b2c32g0s0600hx.out 506,147 11-18-2019 20:56 84d88395 cb_na325b2c32g0s0700hx.inp 4,095 11-18-2019 10:14 015af6fc cb_na325b2c32g0s0700hx.out 506,272 11-18-2019 20:51 26d42fe9 cb_na325b2c32g0s0800hx.inp 4,095 11-18-2019 10:14 23a6838c cb_na325b2c32g0s0800hx.out 505,573 11-18-2019 20:51 f5f00a55 cb_na325b2c32g0s0900hx.inp 4,095 11-18-2019 10:14 2042f5c3 cb_na325b2c32g0s0900hx.out 506,601 11-18-2019 20:52 01c4d255 cb_na325b2c32g0s1000hx.inp 4,099 11-18-2019 10:14 e2228d21 cb_na325b2c32g0s1000hx.out 505,587 11-18-2019 20:49 682f7b11 cb_na325b2c32g0s1100hx.inp 4,099 11-18-2019 10:14 2be275ca cb_na325b2c32g0s1100hx.out 505,325 11-18-2019 20:59 17b64503 cb_na325b2c32g0s1200hx.inp 4,099 11-18-2019 10:14 a75cb978 cb_na325b2c32g0s1200hx.out 505,715 11-18-2019 20:59 03235176 cb_na325b2c32g0s1300hx.inp 4,099 11-18-2019 10:14 1cc93b5f cb_na325b2c32g0s1300hx.out 505,048 11-18-2019 20:52 c4ad9ee2 cb_na325b2c32g0s1400hx.inp 4,099 11-18-2019 10:14 b73e28ab cb_na325b2c32g0s1400hx.out 505,975 11-18-2019 21:02 4bc74050 cb_na325b2c32g0s1500hx.inp 4,099 11-18-2019 10:14 1b3268dc cb_na325b2c32g0s1500hx.out 505,226 11-18-2019 21:05 b601a892
\\v1.2\\cb\\ns245\\ (22) 5,622,258 11-20-2019 09:22 cb_ns245b2c32g0s0500hx.inp 4,145 11-18-2019 16:58 d85473c9 cb_ns245b2c32g0s0500hx.out 507,026 11-20-2019 04:00 ded6759a cb_ns245b2c32g0s0600hx.inp 4,146 11-18-2019 16:58 ad101336 cb_ns245b2c32g0s0600hx.out 507,195 11-20-2019 04:01 fc45fb09 cb_ns245b2c32g0s0700hx.inp 4,146 11-18-2019 16:58 c0146f18 cb_ns245b2c32g0s0700hx.out 506,401 11-20-2019 04:01 7e30bfe5 cb_ns245b2c32g0s0800hx.inp 4,146 11-18-2019 16:58 20376af0 cb_ns245b2c32g0s0800hx.out 506,841 11-20-2019 03:59 8858b4e5 cb_ns245b2c32g0s0900hx.inp 4,146 11-18-2019 16:58 ab34b239 cb_ns245b2c32g0s0900hx.out 507,111 11-20-2019 03:58 7e8d973d cb_ns245b2c32g0s1000hx.inp 4,150 11-18-2019 16:58 7deb8edc cb_ns245b2c32g0s1000hx.out 506,921 11-20-2019 04:07 d11352b8 cb_ns245b2c32g0s1100hx.inp 4,150 11-18-2019 16:59 f96e7e28 cb_ns245b2c32g0s1100hx.out 506,596 11-20-2019 04:19 b9e1738d cb_ns245b2c32g0s1200hx.inp 4,150 11-18-2019 16:59 d92d4d38 cb_ns245b2c32g0s1200hx.out 508,031 11-20-2019 04:04 108dad3b cb_ns245b2c32g0s1300hx.inp 4,150 11-18-2019 16:59 03e2a011 cb_ns245b2c32g0s1300hx.out 506,263 11-20-2019 04:17 49d60695 cb_ns245b2c32g0s1400hx.inp 4,150 11-18-2019 16:59 e768903c cb_ns245b2c32g0s1400hx.out 507,172 11-20-2019 04:14 74b5bf28 cb_ns245b2c32g0s1500hx.inp 4,150 11-18-2019 16:59 64a441ad cb_ns245b2c32g0s1500hx.out 507,072 11-20-2019 04:08 e417e466
\\v1.2\\cb\\ns325\\ (22) 5,606,790 11-20-2019 09:22 cb_ns325b2c32g0s0500hx.inp 4,096 11-18-2019 15:54 d8d26830 cb_ns325b2c32g0s0500hx.out 505,424 11-19-2019 22:59 997aaa03 cb_ns325b2c32g0s0600hx.inp 4,096 11-18-2019 15:54 d19926c6 cb_ns325b2c32g0s0600hx.out 505,840 11-19-2019 22:59 e9526078 cb_ns325b2c32g0s0700hx.inp 4,096 11-18-2019 15:54 a70d287a cb_ns325b2c32g0s0700hx.out 505,213 11-19-2019 23:03 bc2754ff cb_ns325b2c32g0s0800hx.inp 4,096 11-18-2019 15:54 f075bd6f cb_ns325b2c32g0s0800hx.out 505,363 11-19-2019 22:50 800e1fd2 cb_ns325b2c32g0s0900hx.inp 4,096 11-18-2019 15:54 f66c1e4b cb_ns325b2c32g0s0900hx.out 505,849 11-19-2019 22:58 7bf8ba9c cb_ns325b2c32g0s1000hx.inp 4,100 11-18-2019 15:54 5b8978a5 cb_ns325b2c32g0s1000hx.out 506,072 11-19-2019 22:58 3e7b0f06 cb_ns325b2c32g0s1100hx.inp 4,100 11-18-2019 15:54 45bcfa21 cb_ns325b2c32g0s1100hx.out 505,733 11-19-2019 22:59 574d32f5 cb_ns325b2c32g0s1200hx.inp 4,100 11-18-2019 15:54 6276b4b7 cb_ns325b2c32g0s1200hx.out 505,521 11-19-2019 22:58 43bcf249 cb_ns325b2c32g0s1300hx.inp 4,100 11-18-2019 15:54 d8600c64 cb_ns325b2c32g0s1300hx.out 505,475 11-19-2019 23:00 6013ef62 cb_ns325b2c32g0s1400hx.inp 4,100 11-18-2019 15:54 79f95d19 cb_ns325b2c32g0s1400hx.out 505,648 11-19-2019 23:05 a53eedc7 cb_ns325b2c32g0s1500hx.inp 4,100 11-18-2019 15:54 9dad3e8c cb_ns325b2c32g0s1500hx.out 505,572 11-19-2019 23:07 99b54756
\\v1.2\\cc\\ (0) 57,797,503 11-18-2019 16:59
\\v1.2\\cc\\ha245\\ (22) 7,228,300 11-18-2019 20:33 cc_ha245c2c32g0s0500hx.inp 4,119 11-18-2019 02:03 a9d78ab9 cc_ha245c2c32g0s0500hx.out 653,982 11-18-2019 12:58 7b865240 cc_ha245c2c32g0s0600hx.inp 4,120 11-18-2019 02:03 a755d984 cc_ha245c2c32g0s0600hx.out 652,980 11-18-2019 12:55 8fa88983 cc_ha245c2c32g0s0700hx.inp 4,120 11-18-2019 02:03 cd7b2581 cc_ha245c2c32g0s0700hx.out 653,233 11-18-2019 12:52 9da5233d
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
78 of 190 cc_ha245c2c32g0s0800hx.inp 4,120 11-18-2019 02:03 cb3941b5 cc_ha245c2c32g0s0800hx.out 652,503 11-18-2019 12:53 fabdb8b4 cc_ha245c2c32g0s0900hx.inp 4,120 11-18-2019 02:03 bd682f32 cc_ha245c2c32g0s0900hx.out 653,163 11-18-2019 12:55 321ced7f cc_ha245c2c32g0s1000hx.inp 4,124 11-18-2019 02:03 dca30fc5 cc_ha245c2c32g0s1000hx.out 653,098 11-18-2019 12:56 0750c0f6 cc_ha245c2c32g0s1100hx.inp 4,124 11-18-2019 02:03 c84b8007 cc_ha245c2c32g0s1100hx.out 652,668 11-18-2019 12:56 0a9d650e cc_ha245c2c32g0s1200hx.inp 4,124 11-18-2019 02:03 831ff40c cc_ha245c2c32g0s1200hx.out 653,534 11-18-2019 12:59 0ece19c2 cc_ha245c2c32g0s1300hx.inp 4,124 11-18-2019 02:03 331d943f cc_ha245c2c32g0s1300hx.out 652,683 11-18-2019 12:57 2263ff13 cc_ha245c2c32g0s1400hx.inp 4,124 11-18-2019 02:03 335f0218 cc_ha245c2c32g0s1400hx.out 652,554 11-18-2019 12:59 7dea20c3 cc_ha245c2c32g0s1500hx.inp 4,124 11-18-2019 02:04 2ebeda5e cc_ha245c2c32g0s1500hx.out 652,559 11-18-2019 13:02 e9ac0e84
\\v1.2\\cc\\ha325\\ (22) 7,220,632 11-18-2019 20:33 cc_ha325c2c32g0s0500hx.inp 4,065 11-18-2019 00:10 451139a6 cc_ha325c2c32g0s0500hx.out 653,316 11-18-2019 03:10 dc1420c9 cc_ha325c2c32g0s0600hx.inp 4,065 11-18-2019 00:10 cfceaacb cc_ha325c2c32g0s0600hx.out 652,702 11-18-2019 03:07 f05423fe cc_ha325c2c32g0s0700hx.inp 4,065 11-18-2019 00:10 e2b06651 cc_ha325c2c32g0s0700hx.out 651,992 11-18-2019 03:09 3938c7b8 cc_ha325c2c32g0s0800hx.inp 4,065 11-18-2019 00:10 6fa0206d cc_ha325c2c32g0s0800hx.out 652,516 11-18-2019 03:09 fec554f3 cc_ha325c2c32g0s0900hx.inp 4,065 11-18-2019 00:10 33cab0ea cc_ha325c2c32g0s0900hx.out 651,956 11-18-2019 03:10 a6832652 cc_ha325c2c32g0s1000hx.inp 4,069 11-18-2019 00:10 3250be68 cc_ha325c2c32g0s1000hx.out 652,164 11-18-2019 03:12 7d2f5f51 cc_ha325c2c32g0s1100hx.inp 4,069 11-18-2019 00:10 ecb1f650 cc_ha325c2c32g0s1100hx.out 652,237 11-18-2019 03:14 0a3bacdb cc_ha325c2c32g0s1200hx.inp 4,069 11-18-2019 00:10 dc5ca2ec cc_ha325c2c32g0s1200hx.out 651,929 11-18-2019 03:16 ab632dba cc_ha325c2c32g0s1300hx.inp 4,069 11-18-2019 00:10 0040615f cc_ha325c2c32g0s1300hx.out 653,047 11-18-2019 03:18 997d9511 cc_ha325c2c32g0s1400hx.inp 4,069 11-18-2019 00:10 8a36b2fc cc_ha325c2c32g0s1400hx.out 652,147 11-18-2019 03:20 860a5850 cc_ha325c2c32g0s1500hx.inp 4,069 11-18-2019 00:10 4d686c81 cc_ha325c2c32g0s1500hx.out 651,887 11-18-2019 03:13 6a32a166
\\v1.2\\cc\\hs245\\ (22) 7,231,161 11-20-2019 09:22 cc_hs245c2c32g0s0500hx.inp 4,147 11-18-2019 14:27 6080e42c cc_hs245c2c32g0s0500hx.out 653,311 11-19-2019 17:12 3724c673 cc_hs245c2c32g0s0600hx.inp 4,148 11-18-2019 14:27 22a0e815 cc_hs245c2c32g0s0600hx.out 653,392 11-19-2019 17:06 f577dd55 cc_hs245c2c32g0s0700hx.inp 4,148 11-18-2019 14:28 6340487e cc_hs245c2c32g0s0700hx.out 652,649 11-19-2019 17:30 c4cbdb46 cc_hs245c2c32g0s0800hx.inp 4,148 11-18-2019 14:28 d1046f84 cc_hs245c2c32g0s0800hx.out 652,605 11-19-2019 17:10 e5526874 cc_hs245c2c32g0s0900hx.inp 4,148 11-18-2019 14:28 92295fcc cc_hs245c2c32g0s0900hx.out 653,238 11-19-2019 17:16 2143c6cd cc_hs245c2c32g0s1000hx.inp 4,152 11-18-2019 14:28 46d1a341 cc_hs245c2c32g0s1000hx.out 654,043 11-19-2019 17:23 4c4f46ca cc_hs245c2c32g0s1100hx.inp 4,152 11-18-2019 14:28 b6c5a155 cc_hs245c2c32g0s1100hx.out 652,819 11-19-2019 17:24 dc72d85e cc_hs245c2c32g0s1200hx.inp 4,152 11-18-2019 14:28 99b98333 cc_hs245c2c32g0s1200hx.out 652,941 11-19-2019 17:21 44e51255 cc_hs245c2c32g0s1300hx.inp 4,152 11-18-2019 14:28 cfaa41ba cc_hs245c2c32g0s1300hx.out 652,855 11-19-2019 17:42 b5db75b2 cc_hs245c2c32g0s1400hx.inp 4,152 11-18-2019 14:28 72d9ad84 cc_hs245c2c32g0s1400hx.out 653,532 11-19-2019 17:24 9d63ec3d cc_hs245c2c32g0s1500hx.inp 4,152 11-18-2019 14:28 2f0430cd cc_hs245c2c32g0s1500hx.out 654,125 11-19-2019 17:25 8e6a8d0f
\\v1.2\\cc\\hs325\\ (22) 7,218,722 11-20-2019 09:22 cc_hs325c2c32g0s0500hx.inp 4,098 11-18-2019 12:40 ae1b04a7 cc_hs325c2c32g0s0500hx.out 652,509 11-19-2019 11:44 6cd5947e cc_hs325c2c32g0s0600hx.inp 4,098 11-18-2019 12:40 272596fa cc_hs325c2c32g0s0600hx.out 650,846 11-19-2019 11:42 a454308d cc_hs325c2c32g0s0700hx.inp 4,098 11-18-2019 12:40 5a2ee520 cc_hs325c2c32g0s0700hx.out 651,927 11-19-2019 11:52 28b71692 cc_hs325c2c32g0s0800hx.inp 4,098 11-18-2019 12:40 6b77a4a6 cc_hs325c2c32g0s0800hx.out 652,873 11-19-2019 11:46 78f3e36c cc_hs325c2c32g0s0900hx.inp 4,098 11-18-2019 12:40 d5121243 cc_hs325c2c32g0s0900hx.out 652,287 11-19-2019 11:46 11aeaaae cc_hs325c2c32g0s1000hx.inp 4,102 11-18-2019 12:40 44f2036e cc_hs325c2c32g0s1000hx.out 652,338 11-19-2019 11:43 596bc58f
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
79 of 190 cc_hs325c2c32g0s1100hx.inp 4,102 11-18-2019 12:40 1e031a67 cc_hs325c2c32g0s1100hx.out 652,575 11-19-2019 12:04 b3bddf1c cc_hs325c2c32g0s1200hx.inp 4,102 11-18-2019 12:40 4616b5ef cc_hs325c2c32g0s1200hx.out 652,321 11-19-2019 11:54 bcf28eef cc_hs325c2c32g0s1300hx.inp 4,102 11-18-2019 12:40 55378edd cc_hs325c2c32g0s1300hx.out 651,745 11-19-2019 11:52 cce63f2f cc_hs325c2c32g0s1400hx.inp 4,102 11-18-2019 12:41 2d997bab cc_hs325c2c32g0s1400hx.out 651,894 11-19-2019 12:11 3909b75a cc_hs325c2c32g0s1500hx.inp 4,102 11-18-2019 12:41 8c959772 cc_hs325c2c32g0s1500hx.out 652,305 11-19-2019 12:14 4b488d85
\\v1.2\\cc\\na245\\ (22) 7,234,284 11-20-2019 09:22 cc_na245c2c32g0s0500hx.inp 4,146 11-18-2019 11:17 b3f3f276 cc_na245c2c32g0s0500hx.out 653,165 11-19-2019 04:09 cf452249 cc_na245c2c32g0s0600hx.inp 4,147 11-18-2019 11:17 942150f3 cc_na245c2c32g0s0600hx.out 653,535 11-19-2019 04:11 066d5b40 cc_na245c2c32g0s0700hx.inp 4,147 11-18-2019 11:17 2227bc05 cc_na245c2c32g0s0700hx.out 653,844 11-19-2019 04:04 4f114b51 cc_na245c2c32g0s0800hx.inp 4,147 11-18-2019 11:17 d76e67f9 cc_na245c2c32g0s0800hx.out 652,185 11-19-2019 04:13 ca6b33e0 cc_na245c2c32g0s0900hx.inp 4,147 11-18-2019 11:17 ac448350 cc_na245c2c32g0s0900hx.out 653,013 11-19-2019 04:13 5639bdb3 cc_na245c2c32g0s1000hx.inp 4,151 11-18-2019 11:17 dc70fe34 cc_na245c2c32g0s1000hx.out 652,932 11-19-2019 04:27 9ddf7763 cc_na245c2c32g0s1100hx.inp 4,151 11-18-2019 11:17 57a209c2 cc_na245c2c32g0s1100hx.out 653,436 11-19-2019 04:14 1b61dcda cc_na245c2c32g0s1200hx.inp 4,151 11-18-2019 11:17 94f5fd30 cc_na245c2c32g0s1200hx.out 653,923 11-19-2019 04:24 3eb12b62 cc_na245c2c32g0s1300hx.inp 4,151 11-18-2019 11:17 28dea661 cc_na245c2c32g0s1300hx.out 655,030 11-19-2019 04:24 6f56e371 cc_na245c2c32g0s1400hx.inp 4,151 11-18-2019 11:17 80570386 cc_na245c2c32g0s1400hx.out 654,106 11-19-2019 04:09 95eb4446 cc_na245c2c32g0s1500hx.inp 4,151 11-18-2019 11:17 9c4db61f cc_na245c2c32g0s1500hx.out 653,475 11-19-2019 04:41 79e8e5bc
\\v1.2\\cc\\na325\\ (22) 7,217,649 11-20-2019 09:22 cc_na325c2c32g0s0500hx.inp 4,097 11-18-2019 10:14 9a462cd0 cc_na325c2c32g0s0500hx.out 652,264 11-18-2019 20:26 ce42577b cc_na325c2c32g0s0600hx.inp 4,097 11-18-2019 10:15 f3637523 cc_na325c2c32g0s0600hx.out 651,278 11-18-2019 20:26 412de76e cc_na325c2c32g0s0700hx.inp 4,097 11-18-2019 10:15 9eb21e3b cc_na325c2c32g0s0700hx.out 651,789 11-18-2019 20:26 5ea64260 cc_na325c2c32g0s0800hx.inp 4,097 11-18-2019 10:15 7316550f cc_na325c2c32g0s0800hx.out 652,324 11-18-2019 20:28 67262171 cc_na325c2c32g0s0900hx.inp 4,097 11-18-2019 10:15 3a97a920 cc_na325c2c32g0s0900hx.out 652,130 11-18-2019 20:31 7ff8b308 cc_na325c2c32g0s1000hx.inp 4,101 11-18-2019 10:15 3ff8f183 cc_na325c2c32g0s1000hx.out 651,658 11-18-2019 20:36 5051f492 cc_na325c2c32g0s1100hx.inp 4,101 11-18-2019 10:15 5c093065 cc_na325c2c32g0s1100hx.out 652,929 11-18-2019 20:39 c422f80a cc_na325c2c32g0s1200hx.inp 4,101 11-18-2019 10:15 db2b9e48 cc_na325c2c32g0s1200hx.out 651,695 11-18-2019 20:43 a339ee28 cc_na325c2c32g0s1300hx.inp 4,101 11-18-2019 10:15 96a38d5a cc_na325c2c32g0s1300hx.out 652,087 11-18-2019 20:53 1237e7fe cc_na325c2c32g0s1400hx.inp 4,101 11-18-2019 10:15 23067d6c cc_na325c2c32g0s1400hx.out 652,623 11-18-2019 20:47 88ebe190 cc_na325c2c32g0s1500hx.inp 4,101 11-18-2019 10:15 755dd416 cc_na325c2c32g0s1500hx.out 651,781 11-18-2019 20:47 07005e96
\\v1.2\\cc\\ns245\\ (22) 7,230,930 11-20-2019 09:22 cc_ns245c2c32g0s0500hx.inp 4,147 11-18-2019 16:59 a0cd2095 cc_ns245c2c32g0s0500hx.out 653,429 11-20-2019 03:43 8947ffdc cc_ns245c2c32g0s0600hx.inp 4,148 11-18-2019 16:59 a234a356 cc_ns245c2c32g0s0600hx.out 652,698 11-20-2019 04:05 64396988 cc_ns245c2c32g0s0700hx.inp 4,148 11-18-2019 16:59 e3d4033d cc_ns245c2c32g0s0700hx.out 653,330 11-20-2019 03:44 d4273045 cc_ns245c2c32g0s0800hx.inp 4,148 11-18-2019 16:59 519024c7 cc_ns245c2c32g0s0800hx.out 652,925 11-20-2019 03:42 a25ea970 cc_ns245c2c32g0s0900hx.inp 4,148 11-18-2019 16:59 12bd148f cc_ns245c2c32g0s0900hx.out 652,252 11-20-2019 03:52 16b6d977 cc_ns245c2c32g0s1000hx.inp 4,152 11-18-2019 16:59 837c4043 cc_ns245c2c32g0s1000hx.out 653,270 11-20-2019 04:09 355d435b cc_ns245c2c32g0s1100hx.inp 4,152 11-18-2019 17:00 73684257 cc_ns245c2c32g0s1100hx.out 653,036 11-20-2019 03:50 f576ce0f cc_ns245c2c32g0s1200hx.inp 4,152 11-18-2019 17:00 5c146031 cc_ns245c2c32g0s1200hx.out 653,695 11-20-2019 04:11 d8cfae63 cc_ns245c2c32g0s1300hx.inp 4,152 11-18-2019 17:00 0a07a2b8 cc_ns245c2c32g0s1300hx.out 653,996 11-20-2019 03:54 49f19b13
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
80 of 190 cc_ns245c2c32g0s1400hx.inp 4,152 11-18-2019 17:00 b7744e86 cc_ns245c2c32g0s1400hx.out 653,177 11-20-2019 04:00 7ef4453a cc_ns245c2c32g0s1500hx.inp 4,152 11-18-2019 17:00 eaa9d3cf cc_ns245c2c32g0s1500hx.out 653,471 11-20-2019 03:58 fa155903
\\v1.2\\cc\\ns325\\ (22) 7,215,825 11-20-2019 09:22 cc_ns325c2c32g0s0500hx.inp 4,098 11-18-2019 15:55 2023cd30 cc_ns325c2c32g0s0500hx.out 652,195 11-19-2019 22:27 cb83310e cc_ns325c2c32g0s0600hx.inp 4,098 11-18-2019 15:55 a91d5f6d cc_ns325c2c32g0s0600hx.out 651,180 11-19-2019 22:19 eb0fd6e2 cc_ns325c2c32g0s0700hx.inp 4,098 11-18-2019 15:55 d4162cb7 cc_ns325c2c32g0s0700hx.out 651,135 11-19-2019 22:35 41336466 cc_ns325c2c32g0s0800hx.inp 4,098 11-18-2019 15:55 e54f6d31 cc_ns325c2c32g0s0800hx.out 651,211 11-19-2019 22:33 2c2c79d7 cc_ns325c2c32g0s0900hx.inp 4,098 11-18-2019 15:55 5b2adbd4 cc_ns325c2c32g0s0900hx.out 652,804 11-19-2019 22:41 72767913 cc_ns325c2c32g0s1000hx.inp 4,102 11-18-2019 15:55 78cbb7ad cc_ns325c2c32g0s1000hx.out 651,689 11-19-2019 22:35 5a75cd5d cc_ns325c2c32g0s1100hx.inp 4,102 11-18-2019 15:55 223aaea4 cc_ns325c2c32g0s1100hx.out 651,265 11-19-2019 22:34 dd8d58c2 cc_ns325c2c32g0s1200hx.inp 4,102 11-18-2019 15:55 7a2f012c cc_ns325c2c32g0s1200hx.out 651,834 11-19-2019 22:40 55d4d397 cc_ns325c2c32g0s1300hx.inp 4,102 11-18-2019 15:55 690e3a1e cc_ns325c2c32g0s1300hx.out 652,790 11-19-2019 22:45 7d137a0d cc_ns325c2c32g0s1400hx.inp 4,102 11-18-2019 15:55 11a0cf68 cc_ns325c2c32g0s1400hx.out 652,083 11-19-2019 22:45 9691c7f3 cc_ns325c2c32g0s1500hx.inp 4,102 11-18-2019 15:55 b0ac23b1 cc_ns325c2c32g0s1500hx.out 652,537 11-19-2019 22:53 1acb8ac3
\\v1.2\\cd\\ (0) 51,352,243 11-18-2019 17:00
\\v1.2\\cd\\ha245\\ (22) 7,227,144 11-18-2019 20:33 cd_ha245c2c32g0s0500hx.inp 4,122 11-18-2019 02:04 53a9e5e2 cd_ha245c2c32g0s0500hx.out 653,301 11-18-2019 12:58 146e34b0 cd_ha245c2c32g0s0600hx.inp 4,123 11-18-2019 02:04 cb28db5e cd_ha245c2c32g0s0600hx.out 653,056 11-18-2019 12:55 92a451f6 cd_ha245c2c32g0s0700hx.inp 4,123 11-18-2019 02:04 0b690fd9 cd_ha245c2c32g0s0700hx.out 652,201 11-18-2019 12:53 786d32ab cd_ha245c2c32g0s0800hx.inp 4,123 11-18-2019 02:04 527bca04 cd_ha245c2c32g0s0800hx.out 652,655 11-18-2019 12:53 303f47ad cd_ha245c2c32g0s0900hx.inp 4,123 11-18-2019 02:04 59b269fb cd_ha245c2c32g0s0900hx.out 652,560 11-18-2019 12:54 21121f5e cd_ha245c2c32g0s1000hx.inp 4,127 11-18-2019 02:04 be6613fd cd_ha245c2c32g0s1000hx.out 652,941 11-18-2019 12:54 5b8a7f82 cd_ha245c2c32g0s1100hx.inp 4,127 11-18-2019 02:04 46018621 cd_ha245c2c32g0s1100hx.out 652,763 11-18-2019 12:56 f0156b71 cd_ha245c2c32g0s1200hx.inp 4,127 11-18-2019 02:04 8fc15a2e cd_ha245c2c32g0s1200hx.out 653,291 11-18-2019 12:57 36265f16 cd_ha245c2c32g0s1300hx.inp 4,127 11-18-2019 02:04 8a7b557c cd_ha245c2c32g0s1300hx.out 653,594 11-18-2019 12:59 e7949908 cd_ha245c2c32g0s1400hx.inp 4,127 11-18-2019 02:04 75437b6c cd_ha245c2c32g0s1400hx.out 652,248 11-18-2019 13:00 e6f5e1b9 cd_ha245c2c32g0s1500hx.inp 4,127 11-18-2019 02:05 a9a9ed85 cd_ha245c2c32g0s1500hx.out 653,158 11-18-2019 13:01 b8c4b333
\\v1.2\\cd\\ha325\\ (22) 7,216,298 11-18-2019 20:33 cd_ha325c2c32g0s0500hx.inp 4,068 11-18-2019 00:11 33ac603c cd_ha325c2c32g0s0500hx.out 651,983 11-18-2019 03:13 34140bed cd_ha325c2c32g0s0600hx.inp 4,068 11-18-2019 00:11 fc935333 cd_ha325c2c32g0s0600hx.out 652,932 11-18-2019 03:12 455f6d7b cd_ha325c2c32g0s0700hx.inp 4,068 11-18-2019 00:11 63a050d3 cd_ha325c2c32g0s0700hx.out 651,836 11-18-2019 03:14 67800b3f cd_ha325c2c32g0s0800hx.inp 4,068 11-18-2019 00:11 8f7db906 cd_ha325c2c32g0s0800hx.out 652,036 11-18-2019 03:14 6c04210b cd_ha325c2c32g0s0900hx.inp 4,068 11-18-2019 00:11 8c90ec87 cd_ha325c2c32g0s0900hx.out 651,855 11-18-2019 03:14 29756e84 cd_ha325c2c32g0s1000hx.inp 4,072 11-18-2019 00:11 7709592a cd_ha325c2c32g0s1000hx.out 651,330 11-18-2019 03:17 adaeb06c cd_ha325c2c32g0s1100hx.inp 4,072 11-18-2019 00:11 fa945512 cd_ha325c2c32g0s1100hx.out 651,765 11-18-2019 03:21 ec8c359e cd_ha325c2c32g0s1200hx.inp 4,072 11-18-2019 00:11 1118bc3a cd_ha325c2c32g0s1200hx.out 651,977 11-18-2019 03:21 a86c3464 cd_ha325c2c32g0s1300hx.inp 4,072 11-18-2019 00:11 51788ea1 cd_ha325c2c32g0s1300hx.out 652,246 11-18-2019 03:21 49b50419 cd_ha325c2c32g0s1400hx.inp 4,072 11-18-2019 00:11 70061494 cd_ha325c2c32g0s1400hx.out 651,649 11-18-2019 03:22 de59a30e cd_ha325c2c32g0s1500hx.inp 4,072 11-18-2019 00:11 5d4791f2
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
81 of 190 cd_ha325c2c32g0s1500hx.out 651,917 11-18-2019 03:17 97fb962d
\\v1.2\\cd\\hs245\\ (22) 5,619,944 11-20-2019 09:22 cd_hs245c2c32g0s0500hx.inp 4,150 11-18-2019 14:28 839022f5 cd_hs245c2c32g0s0500hx.out 505,724 11-19-2019 17:21 b7ac78dd cd_hs245c2c32g0s0600hx.inp 4,151 11-18-2019 14:28 d2527aac cd_hs245c2c32g0s0600hx.out 507,009 11-19-2019 17:20 eafc884a cd_hs245c2c32g0s0700hx.inp 4,151 11-18-2019 14:28 84bbc091 cd_hs245c2c32g0s0700hx.out 506,043 11-19-2019 17:19 4a49a4ef cd_hs245c2c32g0s0800hx.inp 4,151 11-18-2019 14:29 9f77b5b9 cd_hs245c2c32g0s0800hx.out 506,672 11-19-2019 17:25 a828bfc9 cd_hs245c2c32g0s0900hx.inp 4,151 11-18-2019 14:29 c3fadbb0 cd_hs245c2c32g0s0900hx.out 507,197 11-19-2019 17:19 ddc8e252 cd_hs245c2c32g0s1000hx.inp 4,155 11-18-2019 14:29 26421ec9 cd_hs245c2c32g0s1000hx.out 507,034 11-19-2019 17:20 6a19a76d cd_hs245c2c32g0s1100hx.inp 4,155 11-18-2019 14:29 5b1d26be cd_hs245c2c32g0s1100hx.out 507,654 11-19-2019 17:27 a219fa9d cd_hs245c2c32g0s1200hx.inp 4,155 11-18-2019 14:29 8e21817c cd_hs245c2c32g0s1200hx.out 507,138 11-19-2019 17:44 73953eb9 cd_hs245c2c32g0s1300hx.inp 4,155 11-18-2019 14:29 2aa0f4b5 cd_hs245c2c32g0s1300hx.out 506,488 11-19-2019 17:31 4142d7ad cd_hs245c2c32g0s1400hx.inp 4,155 11-18-2019 14:29 06c37ee2 cd_hs245c2c32g0s1400hx.out 506,321 11-19-2019 17:41 c6d96852 cd_hs245c2c32g0s1500hx.inp 4,155 11-18-2019 14:29 42656897 cd_hs245c2c32g0s1500hx.out 506,980 11-19-2019 17:37 44e99918
\\v1.2\\cd\\hs325\\ (22) 5,608,995 11-20-2019 09:22 cd_hs325c2c32g0s0500hx.inp 4,101 11-18-2019 12:41 8050d3c3 cd_hs325c2c32g0s0500hx.out 506,309 11-19-2019 11:49 5d8a910f cd_hs325c2c32g0s0600hx.inp 4,101 11-18-2019 12:41 960db7be cd_hs325c2c32g0s0600hx.out 506,309 11-19-2019 11:50 9d387157 cd_hs325c2c32g0s0700hx.inp 4,101 11-18-2019 12:41 a11d4550 cd_hs325c2c32g0s0700hx.out 504,425 11-19-2019 12:02 60b2e7be cd_hs325c2c32g0s0800hx.inp 4,101 11-18-2019 12:41 807108f4 cd_hs325c2c32g0s0800hx.out 506,066 11-19-2019 11:54 ac948dd3 cd_hs325c2c32g0s0900hx.inp 4,101 11-18-2019 12:41 babc6544 cd_hs325c2c32g0s0900hx.out 506,395 11-19-2019 11:58 b617bbb1 cd_hs325c2c32g0s1000hx.inp 4,105 11-18-2019 12:41 4d3137e7 cd_hs325c2c32g0s1000hx.out 505,232 11-19-2019 11:55 f3d05aef cd_hs325c2c32g0s1100hx.inp 4,105 11-18-2019 12:41 8501a3be cd_hs325c2c32g0s1100hx.out 505,953 11-19-2019 12:00 73452b51 cd_hs325c2c32g0s1200hx.inp 4,105 11-18-2019 12:41 3b61bbb6 cd_hs325c2c32g0s1200hx.out 505,624 11-19-2019 12:08 973c3c7b cd_hs325c2c32g0s1300hx.inp 4,105 11-18-2019 12:41 d77d77fb cd_hs325c2c32g0s1300hx.out 505,391 11-19-2019 12:08 87190fbd cd_hs325c2c32g0s1400hx.inp 4,105 11-18-2019 12:42 44b3c206 cd_hs325c2c32g0s1400hx.out 505,758 11-19-2019 12:11 08b4ece2 cd_hs325c2c32g0s1500hx.inp 4,105 11-18-2019 12:42 10e7fae4 cd_hs325c2c32g0s1500hx.out 506,398 11-19-2019 12:09 ea67719c
\\v1.2\\cd\\na245\\ (22) 7,228,276 11-20-2019 09:22 cd_na245c2c32g0s0500hx.inp 4,149 11-18-2019 11:18 eb8196f5 cd_na245c2c32g0s0500hx.out 653,153 11-19-2019 04:20 ebd2c18e cd_na245c2c32g0s0600hx.inp 4,150 11-18-2019 11:18 dce5ef28 cd_na245c2c32g0s0600hx.out 652,912 11-19-2019 04:18 0c8a28a3 cd_na245c2c32g0s0700hx.inp 4,150 11-18-2019 11:18 d4514c51 cd_na245c2c32g0s0700hx.out 653,112 11-19-2019 04:28 c27e6f0d cd_na245c2c32g0s0800hx.inp 4,150 11-18-2019 11:18 e6702578 cd_na245c2c32g0s0800hx.out 653,043 11-19-2019 04:30 877cc7a4 cd_na245c2c32g0s0900hx.inp 4,150 11-18-2019 11:18 d9d13515 cd_na245c2c32g0s0900hx.out 652,146 11-19-2019 04:23 edfdc861 cd_na245c2c32g0s1000hx.inp 4,154 11-18-2019 11:18 b64cddd5 cd_na245c2c32g0s1000hx.out 652,794 11-19-2019 04:24 66b1f240 cd_na245c2c32g0s1100hx.inp 4,154 11-18-2019 11:18 4ca32f96 cd_na245c2c32g0s1100hx.out 652,831 11-19-2019 04:27 a0c81284 cd_na245c2c32g0s1200hx.inp 4,154 11-18-2019 11:18 9dfc72bf cd_na245c2c32g0s1200hx.out 653,385 11-19-2019 04:31 f0bdb46f cd_na245c2c32g0s1300hx.inp 4,154 11-18-2019 11:18 ad1515fb cd_na245c2c32g0s1300hx.out 652,956 11-19-2019 04:36 31f5a80e cd_na245c2c32g0s1400hx.inp 4,154 11-18-2019 11:18 3b5fd30b cd_na245c2c32g0s1400hx.out 653,284 11-19-2019 04:49 4bf0c6f1 cd_na245c2c32g0s1500hx.inp 4,154 11-18-2019 11:18 9b5c0990 cd_na245c2c32g0s1500hx.out 652,987 11-19-2019 04:49 88073e0c
\\v1.2\\cd\\na325\\ (22) 7,220,316 11-20-2019 09:22 cd_na325c2c32g0s0500hx.inp 4,100 11-18-2019 10:15 2f7d70d5 cd_na325c2c32g0s0500hx.out 652,253 11-18-2019 20:40 72bf1d8f
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
82 of 190 cd_na325c2c32g0s0600hx.inp 4,100 11-18-2019 10:15 7bb2f205 cd_na325c2c32g0s0600hx.out 652,420 11-18-2019 20:34 fabb7684 cd_na325c2c32g0s0700hx.inp 4,100 11-18-2019 10:16 a11faa1c cd_na325c2c32g0s0700hx.out 652,172 11-18-2019 20:43 ecb050a0 cd_na325c2c32g0s0800hx.inp 4,100 11-18-2019 10:16 3a731bc9 cd_na325c2c32g0s0800hx.out 651,291 11-18-2019 20:43 ce0543df cd_na325c2c32g0s0900hx.inp 4,100 11-18-2019 10:16 10655dde cd_na325c2c32g0s0900hx.out 652,240 11-18-2019 20:44 2c7c1318 cd_na325c2c32g0s1000hx.inp 4,104 11-18-2019 10:16 0d70e8a4 cd_na325c2c32g0s1000hx.out 652,291 11-18-2019 20:47 6220e4d2 cd_na325c2c32g0s1100hx.inp 4,104 11-18-2019 10:16 f00ccf7d cd_na325c2c32g0s1100hx.out 652,174 11-18-2019 20:47 8218fccc cd_na325c2c32g0s1200hx.inp 4,104 11-18-2019 10:16 02d92233 cd_na325c2c32g0s1200hx.out 653,352 11-18-2019 20:50 2b278fdb cd_na325c2c32g0s1300hx.inp 4,104 11-18-2019 10:16 ec59b52c cd_na325c2c32g0s1300hx.out 653,066 11-18-2019 20:53 280c4112 cd_na325c2c32g0s1400hx.inp 4,104 11-18-2019 10:16 978ca132 cd_na325c2c32g0s1400hx.out 652,066 11-18-2019 21:01 3769ac18 cd_na325c2c32g0s1500hx.inp 4,104 11-18-2019 10:16 af9629fe cd_na325c2c32g0s1500hx.out 651,867 11-18-2019 20:53 a33e5be8
\\v1.2\\cd\\ns245\\ (22) 5,622,328 11-20-2019 09:22 cd_ns245c2c32g0s0500hx.inp 4,150 11-18-2019 17:00 cd787c64 cd_ns245c2c32g0s0500hx.out 506,776 11-20-2019 03:56 1a8e6e24 cd_ns245c2c32g0s0600hx.inp 4,151 11-18-2019 17:00 67fd3c8f cd_ns245c2c32g0s0600hx.out 507,025 11-20-2019 03:51 1d4df087 cd_ns245c2c32g0s0700hx.inp 4,151 11-18-2019 17:00 311486b2 cd_ns245c2c32g0s0700hx.out 506,890 11-20-2019 03:58 538523d6 cd_ns245c2c32g0s0800hx.inp 4,151 11-18-2019 17:00 2ad8f39a cd_ns245c2c32g0s0800hx.out 506,759 11-20-2019 04:03 585baf5f cd_ns245c2c32g0s0900hx.inp 4,151 11-18-2019 17:00 76559d93 cd_ns245c2c32g0s0900hx.out 507,345 11-20-2019 03:56 42c08f33 cd_ns245c2c32g0s1000hx.inp 4,155 11-18-2019 17:01 db6e01b1 cd_ns245c2c32g0s1000hx.out 507,190 11-20-2019 04:02 271c4af1 cd_ns245c2c32g0s1100hx.inp 4,155 11-18-2019 17:01 a63139c6 cd_ns245c2c32g0s1100hx.out 507,054 11-20-2019 04:04 111425c5 cd_ns245c2c32g0s1200hx.inp 4,155 11-18-2019 17:01 730d9e04 cd_ns245c2c32g0s1200hx.out 506,633 11-20-2019 04:03 139d83ac cd_ns245c2c32g0s1300hx.inp 4,155 11-18-2019 17:01 d78cebcd cd_ns245c2c32g0s1300hx.out 506,721 11-20-2019 04:08 c12d7407 cd_ns245c2c32g0s1400hx.inp 4,155 11-18-2019 17:01 fbef619a cd_ns245c2c32g0s1400hx.out 507,267 11-20-2019 04:12 6707731d cd_ns245c2c32g0s1500hx.inp 4,155 11-18-2019 17:01 bf4977ef cd_ns245c2c32g0s1500hx.out 506,984 11-20-2019 04:34 972d85df
\\v1.2\\cd\\ns325\\ (22) 5,608,942 11-20-2019 09:22 cd_ns325c2c32g0s0500hx.inp 4,101 11-18-2019 15:56 69aa1d08 cd_ns325c2c32g0s0500hx.out 505,591 11-19-2019 22:37 98731229 cd_ns325c2c32g0s0600hx.inp 4,101 11-18-2019 15:56 7ff77975 cd_ns325c2c32g0s0600hx.out 505,739 11-19-2019 22:31 f02502e3 cd_ns325c2c32g0s0700hx.inp 4,101 11-18-2019 15:56 48e78b9b cd_ns325c2c32g0s0700hx.out 506,335 11-19-2019 22:37 c95d80fe cd_ns325c2c32g0s0800hx.inp 4,101 11-18-2019 15:56 698bc63f cd_ns325c2c32g0s0800hx.out 505,242 11-19-2019 22:39 332fc339 cd_ns325c2c32g0s0900hx.inp 4,101 11-18-2019 15:56 5346ab8f cd_ns325c2c32g0s0900hx.out 505,056 11-19-2019 22:45 b1e6c332 cd_ns325c2c32g0s1000hx.inp 4,105 11-18-2019 15:56 22e848df cd_ns325c2c32g0s1000hx.out 506,333 11-19-2019 22:54 7f8d54dd cd_ns325c2c32g0s1100hx.inp 4,105 11-18-2019 15:56 ead8dc86 cd_ns325c2c32g0s1100hx.out 506,418 11-19-2019 22:48 48d814da cd_ns325c2c32g0s1200hx.inp 4,105 11-18-2019 15:56 54b8c48e cd_ns325c2c32g0s1200hx.out 505,455 11-19-2019 22:50 785bf6da cd_ns325c2c32g0s1300hx.inp 4,105 11-18-2019 15:56 b8a408c3 cd_ns325c2c32g0s1300hx.out 505,733 11-19-2019 22:55 fd231332 cd_ns325c2c32g0s1400hx.inp 4,105 11-18-2019 15:56 2b6abd3e cd_ns325c2c32g0s1400hx.out 505,677 11-19-2019 22:55 12fd3556 cd_ns325c2c32g0s1500hx.inp 4,105 11-18-2019 15:57 7f3e85dc cd_ns325c2c32g0s1500hx.out 506,228 11-19-2019 22:59 83bc535d
\\v1.2\\ce\\ (0) 47,291,296 11-18-2019 17:01
\\v1.2\\ce\\ha245\\ (18) 5,916,017 11-22-2019 12:48 ce_ha245c2c32g0s001vfio.inp 4,120 11-18-2019 02:05 580c930d ce_ha245c2c32g0s001vfio.out 653,163 11-18-2019 11:57 8010f132 ce_ha245c2c32g0s005vfio.inp 4,120 11-18-2019 02:05 7234699c ce_ha245c2c32g0s005vfio.out 652,627 11-18-2019 11:45 2c3feebf ce_ha245c2c32g0s010vfio.inp 4,120 11-18-2019 02:05 374b12f6
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
83 of 190 ce_ha245c2c32g0s010vfio.out 653,128 11-18-2019 11:47 0691b8ce ce_ha245c2c32g0s030vfio.inp 4,120 11-18-2019 02:05 5bf46d82 ce_ha245c2c32g0s030vfio.out 653,533 11-18-2019 12:10 ae48acb7 ce_ha245c2c32g0s050vfio.inp 4,120 11-18-2019 02:05 1a397184 ce_ha245c2c32g0s050vfio.out 652,350 11-18-2019 12:30 0df2a3fa ce_ha245c2c32g0s070vfio.inp 4,120 11-18-2019 02:05 51bbed2f ce_ha245c2c32g0s070vfio.out 653,225 11-18-2019 12:43 1850b7bf ce_ha245c2c32g0s090vfio.inp 4,120 11-18-2019 02:05 d0da7fab ce_ha245c2c32g0s090vfio.out 653,798 11-18-2019 12:53 4e350502 ce_ha245c2c32g0s095vfio.inp 4,120 11-18-2019 02:05 95da89d2 ce_ha245c2c32g0s095vfio.out 653,948 11-18-2019 12:53 f9e0784f ce_ha245c2c32g0s100vfio.inp 4,120 11-18-2019 02:06 bd682f32 ce_ha245c2c32g0s100vfio.out 653,165 11-18-2019 12:55 db2ed516
\\v1.2\\ce\\ha325\\ (18) 5,905,789 11-22-2019 12:48 ce_ha325c2c32g0s001vfio.inp 4,065 11-18-2019 00:11 905f8c61 ce_ha325c2c32g0s001vfio.out 651,960 11-18-2019 02:13 0f6e5719 ce_ha325c2c32g0s005vfio.inp 4,065 11-18-2019 00:12 a3e2ca94 ce_ha325c2c32g0s005vfio.out 652,602 11-18-2019 01:58 e919d123 ce_ha325c2c32g0s010vfio.inp 4,065 11-18-2019 00:12 6a158f12 ce_ha325c2c32g0s010vfio.out 652,497 11-18-2019 02:02 0a0706b8 ce_ha325c2c32g0s030vfio.inp 4,065 11-18-2019 00:12 554daf31 ce_ha325c2c32g0s030vfio.out 651,780 11-18-2019 02:26 e966d8e4 ce_ha325c2c32g0s050vfio.inp 4,065 11-18-2019 00:12 f0409a8f ce_ha325c2c32g0s050vfio.out 651,682 11-18-2019 02:46 cdec6bf7 ce_ha325c2c32g0s070vfio.inp 4,065 11-18-2019 00:12 93198e37 ce_ha325c2c32g0s070vfio.out 652,596 11-18-2019 03:00 738fa571 ce_ha325c2c32g0s090vfio.inp 4,065 11-18-2019 00:12 a8cc55a3 ce_ha325c2c32g0s090vfio.out 652,142 11-18-2019 03:11 e960ed60 ce_ha325c2c32g0s095vfio.inp 4,065 11-18-2019 00:12 b35971a2 ce_ha325c2c32g0s095vfio.out 651,987 11-18-2019 03:12 dd7f7772 ce_ha325c2c32g0s100vfio.inp 4,065 11-18-2019 00:12 33cab0ea ce_ha325c2c32g0s100vfio.out 651,958 11-18-2019 03:12 6937403e
\\v1.2\\ce\\hs245\\ (18) 5,914,938 11-22-2019 12:48 ce_hs245c2c32g0s001vfi.inp 4,148 11-18-2019 14:29 cd1f21a4 ce_hs245c2c32g0s001vfi.out 652,693 11-19-2019 17:31 bb52c495 ce_hs245c2c32g0s005vfi.inp 4,148 11-18-2019 14:29 075b6bb3 ce_hs245c2c32g0s005vfi.out 653,934 11-19-2019 17:04 8862dfe2 ce_hs245c2c32g0s010vfi.inp 4,148 11-18-2019 14:30 c060cf91 ce_hs245c2c32g0s010vfi.out 653,216 11-19-2019 17:01 07757382 ce_hs245c2c32g0s030vfi.inp 4,148 11-18-2019 14:30 3f601c88 ce_hs245c2c32g0s030vfi.out 652,175 11-19-2019 16:57 f5d5cbf5 ce_hs245c2c32g0s050vfi.inp 4,148 11-18-2019 14:30 4f6588ba ce_hs245c2c32g0s050vfi.out 652,922 11-19-2019 17:05 20709482 ce_hs245c2c32g0s070vfi.inp 4,148 11-18-2019 14:30 aeff92d0 ce_hs245c2c32g0s070vfi.out 653,614 11-19-2019 17:20 95a71012 ce_hs245c2c32g0s090vfi.inp 4,148 11-18-2019 14:30 08d03c30 ce_hs245c2c32g0s090vfi.out 653,633 11-19-2019 17:37 628785e1 ce_hs245c2c32g0s095vfi.inp 4,148 11-18-2019 14:30 40a5fd06 ce_hs245c2c32g0s095vfi.out 652,183 11-19-2019 17:29 d86ec42e ce_hs245c2c32g0s100vfi.inp 4,148 11-18-2019 14:30 92295fcc ce_hs245c2c32g0s100vfi.out 653,236 11-19-2019 17:41 711da5dc
\\v1.2\\ce\\hs325\\ (18) 5,906,417 11-22-2019 12:48 ce_hs325c2c32g0s001vfi.inp 4,098 11-18-2019 12:42 3e294899 ce_hs325c2c32g0s001vfi.out 652,079 11-19-2019 11:45 32f5e870 ce_hs325c2c32g0s005vfi.inp 4,098 11-18-2019 12:42 e5e28b17 ce_hs325c2c32g0s005vfi.out 653,393 11-19-2019 11:29 644eed28 ce_hs325c2c32g0s010vfi.inp 4,098 11-18-2019 12:42 eeccc889 ce_hs325c2c32g0s010vfi.out 652,169 11-19-2019 11:34 dd865eea ce_hs325c2c32g0s030vfi.inp 4,098 11-18-2019 12:42 4fe3b629 ce_hs325c2c32g0s030vfi.out 651,399 11-19-2019 11:36 6fc3a5da ce_hs325c2c32g0s050vfi.inp 4,098 11-18-2019 12:42 f4f69daf ce_hs325c2c32g0s050vfi.out 652,298 11-19-2019 11:38 d81696fe ce_hs325c2c32g0s070vfi.inp 4,098 11-18-2019 12:42 15665b21 ce_hs325c2c32g0s070vfi.out 651,982 11-19-2019 11:52 cdf75dec ce_hs325c2c32g0s090vfi.inp 4,098 11-18-2019 12:42 27ba0b8d ce_hs325c2c32g0s090vfi.out 651,445 11-19-2019 12:08 db9bb4b7 ce_hs325c2c32g0s095vfi.inp 4,098 11-18-2019 12:42 cf695e80 ce_hs325c2c32g0s095vfi.out 652,487 11-19-2019 12:06 5ba57911 ce_hs325c2c32g0s100vfi.inp 4,098 11-18-2019 12:43 d5121243 ce_hs325c2c32g0s100vfi.out 652,283 11-19-2019 12:24 a80cb0be
\\v1.2\\ce\\na245\\ (18) 5,915,991 11-22-2019 12:48 ce_na245c2c32g0s001vfio.inp 4,147 11-18-2019 11:19 545d257b ce_na245c2c32g0s001vfio.out 653,469 11-19-2019 03:30 02b7e918
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
84 of 190 ce_na245c2c32g0s005vfio.inp 4,147 11-18-2019 11:19 31f60efd ce_na245c2c32g0s005vfio.out 654,130 11-19-2019 03:22 1b749bd6 ce_na245c2c32g0s010vfio.inp 4,147 11-18-2019 11:19 29bc48ac ce_na245c2c32g0s010vfio.out 654,150 11-19-2019 03:33 2a65b6c8 ce_na245c2c32g0s030vfio.inp 4,147 11-18-2019 11:19 28a06559 ce_na245c2c32g0s030vfio.out 652,990 11-19-2019 04:08 c36841c5 ce_na245c2c32g0s050vfio.inp 4,147 11-18-2019 11:19 7aa84c06 ce_na245c2c32g0s050vfio.out 652,475 11-19-2019 04:26 8a3a055d ce_na245c2c32g0s070vfio.inp 4,147 11-18-2019 11:19 ccf3934a ce_na245c2c32g0s070vfio.out 652,368 11-19-2019 04:36 1f1a94e3 ce_na245c2c32g0s090vfio.inp 4,147 11-18-2019 11:19 95f08d1d ce_na245c2c32g0s090vfio.out 652,920 11-19-2019 04:39 3805ec50 ce_na245c2c32g0s095vfio.inp 4,147 11-18-2019 11:19 23ffb6fc ce_na245c2c32g0s095vfio.out 653,152 11-19-2019 04:44 42350c7c ce_na245c2c32g0s100vfio.inp 4,147 11-18-2019 11:19 ac448350 ce_na245c2c32g0s100vfio.out 653,014 11-19-2019 04:51 8e84c3c1
\\v1.2\\ce\\na325\\ (18) 5,907,772 11-22-2019 12:48 ce_na325c2c32g0s001vfio.inp 4,097 11-18-2019 10:16 16edca4d ce_na325c2c32g0s001vfio.out 651,635 11-18-2019 19:38 5684a483 ce_na325c2c32g0s005vfio.inp 4,097 11-18-2019 10:16 719f4c76 ce_na325c2c32g0s005vfio.out 653,687 11-18-2019 19:30 e42b6a76 ce_na325c2c32g0s010vfio.inp 4,097 11-18-2019 10:17 8b29d34c ce_na325c2c32g0s010vfio.out 652,278 11-18-2019 19:45 b77a5b5a ce_na325c2c32g0s030vfio.inp 4,097 11-18-2019 10:17 16ee6be9 ce_na325c2c32g0s030vfio.out 651,662 11-18-2019 20:21 f5a5358b ce_na325c2c32g0s050vfio.inp 4,097 11-18-2019 10:17 f4581f81 ce_na325c2c32g0s050vfio.out 651,972 11-18-2019 20:35 90240440 ce_na325c2c32g0s070vfio.inp 4,097 11-18-2019 10:17 70557a1d ce_na325c2c32g0s070vfio.out 652,454 11-18-2019 20:41 a92ed2c7 ce_na325c2c32g0s090vfio.inp 4,097 11-18-2019 10:17 19bef4d1 ce_na325c2c32g0s090vfio.out 652,876 11-18-2019 20:49 68de2760 ce_na325c2c32g0s095vfio.inp 4,097 11-18-2019 10:17 f56c0c2c ce_na325c2c32g0s095vfio.out 652,203 11-18-2019 20:43 9264639b ce_na325c2c32g0s100vfio.inp 4,097 11-18-2019 10:17 3a97a920 ce_na325c2c32g0s100vfio.out 652,132 11-18-2019 20:53 cf74d4fa
\\v1.2\\ce\\ns245\\ (18) 5,916,384 11-22-2019 12:48 ce_ns245c2c32g0s001vfi.inp 4,148 11-18-2019 17:01 4d8b6ae7 ce_ns245c2c32g0s001vfi.out 653,473 11-20-2019 03:54 d44d339d ce_ns245c2c32g0s005vfi.inp 4,148 11-18-2019 17:01 87cf20f0 ce_ns245c2c32g0s005vfi.out 652,319 11-20-2019 03:37 41a3085c ce_ns245c2c32g0s010vfi.inp 4,148 11-18-2019 17:01 40f484d2 ce_ns245c2c32g0s010vfi.out 654,202 11-20-2019 03:34 e94a93b0 ce_ns245c2c32g0s030vfi.inp 4,148 11-18-2019 17:01 bff457cb ce_ns245c2c32g0s030vfi.out 653,346 11-20-2019 03:45 c94a09ec ce_ns245c2c32g0s050vfi.inp 4,148 11-18-2019 17:01 cff1c3f9 ce_ns245c2c32g0s050vfi.out 652,896 11-20-2019 03:49 2e20786b ce_ns245c2c32g0s070vfi.inp 4,148 11-18-2019 17:02 2e6bd993 ce_ns245c2c32g0s070vfi.out 653,809 11-20-2019 04:02 76b1c286 ce_ns245c2c32g0s090vfi.inp 4,148 11-18-2019 17:02 88447773 ce_ns245c2c32g0s090vfi.out 653,760 11-20-2019 04:11 a9695e5f ce_ns245c2c32g0s095vfi.inp 4,148 11-18-2019 17:02 c031b645 ce_ns245c2c32g0s095vfi.out 652,995 11-20-2019 04:14 c749fbf9 ce_ns245c2c32g0s100vfi.inp 4,148 11-18-2019 17:02 12bd148f ce_ns245c2c32g0s100vfi.out 652,252 11-20-2019 04:18 9f583568
\\v1.2\\ce\\ns325\\ (18) 5,907,988 11-22-2019 12:48 ce_ns325c2c32g0s001vfi.inp 4,098 11-18-2019 15:57 b011810e ce_ns325c2c32g0s001vfi.out 652,178 11-19-2019 22:34 e484373c ce_ns325c2c32g0s005vfi.inp 4,098 11-18-2019 15:57 6bda4280 ce_ns325c2c32g0s005vfi.out 651,816 11-19-2019 22:14 ad8c5190 ce_ns325c2c32g0s010vfi.inp 4,098 11-18-2019 15:57 60f4011e ce_ns325c2c32g0s010vfi.out 652,599 11-19-2019 22:11 8a8542cc ce_ns325c2c32g0s030vfi.inp 4,098 11-18-2019 15:57 c1db7fbe ce_ns325c2c32g0s030vfi.out 652,447 11-19-2019 22:24 559da400 ce_ns325c2c32g0s050vfi.inp 4,098 11-18-2019 15:57 7ace5438 ce_ns325c2c32g0s050vfi.out 652,589 11-19-2019 22:39 48204f79 ce_ns325c2c32g0s070vfi.inp 4,098 11-18-2019 15:57 9b5e92b6 ce_ns325c2c32g0s070vfi.out 652,404 11-19-2019 22:54 d3b657bb ce_ns325c2c32g0s090vfi.inp 4,098 11-18-2019 15:57 a982c21a ce_ns325c2c32g0s090vfi.out 652,449 11-19-2019 22:58 75311562 ce_ns325c2c32g0s095vfi.inp 4,098 11-18-2019 15:57 41519717 ce_ns325c2c32g0s095vfi.out 651,819 11-19-2019 22:58 2b749928 ce_ns325c2c32g0s100vfi.inp 4,098 11-18-2019 15:57 5b2adbd4 ce_ns325c2c32g0s100vfi.out 652,805 11-19-2019 23:00 1f3c7166
\\v1.2\\cf\\ (0) 42,020,028 11-18-2019 17:02
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
85 of 190
\\v1.2\\cf\\ha245\\ (18) 5,914,024 11-22-2019 12:48 cf_ha245c2c32g0s001vfio.inp 4,123 11-18-2019 02:06 23335aed cf_ha245c2c32g0s001vfio.out 653,520 11-18-2019 11:56 889419fc cf_ha245c2c32g0s005vfio.inp 4,123 11-18-2019 02:06 3126f199 cf_ha245c2c32g0s005vfio.out 652,263 11-18-2019 11:45 2d3157e4 cf_ha245c2c32g0s010vfio.inp 4,123 11-18-2019 02:06 2ea24659 cf_ha245c2c32g0s010vfio.out 652,587 11-18-2019 11:52 230da691 cf_ha245c2c32g0s030vfio.inp 4,123 11-18-2019 02:06 918c1c64 cf_ha245c2c32g0s030vfio.out 652,922 11-18-2019 12:15 3201112f cf_ha245c2c32g0s050vfio.inp 4,123 11-18-2019 02:06 3268025b cf_ha245c2c32g0s050vfio.out 653,305 11-18-2019 12:33 8f264a6f cf_ha245c2c32g0s070vfio.inp 4,123 11-18-2019 02:06 da4ef00b cf_ha245c2c32g0s070vfio.out 653,397 11-18-2019 12:45 32f3b335 cf_ha245c2c32g0s090vfio.inp 4,123 11-18-2019 02:06 88bcd105 cf_ha245c2c32g0s090vfio.out 653,165 11-18-2019 12:53 ab8abd30 cf_ha245c2c32g0s095vfio.inp 4,123 11-18-2019 02:06 5f6e4fed cf_ha245c2c32g0s095vfio.out 653,196 11-18-2019 12:55 b3e38926 cf_ha245c2c32g0s100vfio.inp 4,123 11-18-2019 02:06 59b269fb cf_ha245c2c32g0s100vfio.out 652,562 11-18-2019 12:55 e1720d93
\\v1.2\\cf\\ha325\\ (18) 5,906,919 11-22-2019 12:48 cf_ha325c2c32g0s001vfio.inp 4,068 11-18-2019 00:12 3607a982 cf_ha325c2c32g0s001vfio.out 652,896 11-18-2019 02:11 6d54e42c cf_ha325c2c32g0s005vfio.inp 4,068 11-18-2019 00:12 7bb10f28 cf_ha325c2c32g0s005vfio.out 652,938 11-18-2019 01:57 98ec2e16 cf_ha325c2c32g0s010vfio.inp 4,068 11-18-2019 00:12 0cdd5109 cf_ha325c2c32g0s010vfio.out 651,985 11-18-2019 02:05 e9ec80bd cf_ha325c2c32g0s030vfio.inp 4,068 11-18-2019 00:13 aa7826b9 cf_ha325c2c32g0s030vfio.out 651,610 11-18-2019 02:31 5c88bdb5 cf_ha325c2c32g0s050vfio.inp 4,068 11-18-2019 00:13 f16f8940 cf_ha325c2c32g0s050vfio.out 652,446 11-18-2019 02:47 65ad5335 cf_ha325c2c32g0s070vfio.inp 4,068 11-18-2019 00:13 a0e1f455 cf_ha325c2c32g0s070vfio.out 651,873 11-18-2019 02:59 f81482e7 cf_ha325c2c32g0s090vfio.inp 4,068 11-18-2019 00:13 cf060ec2 cf_ha325c2c32g0s090vfio.out 651,792 11-18-2019 03:08 177c64f6 cf_ha325c2c32g0s095vfio.inp 4,068 11-18-2019 00:13 f399e7cf cf_ha325c2c32g0s095vfio.out 652,910 11-18-2019 03:09 2142399f cf_ha325c2c32g0s100vfio.inp 4,068 11-18-2019 00:13 8c90ec87 cf_ha325c2c32g0s100vfio.out 651,857 11-18-2019 03:12 bc0d22a1
\\v1.2\\cf\\hs245\\ (18) 4,598,475 11-22-2019 12:48 cf_hs245c2c32g0s001vfi.inp 4,151 11-18-2019 14:30 5c05ea54 cf_hs245c2c32g0s001vfi.out 505,971 11-19-2019 17:24 05a5da85 cf_hs245c2c32g0s005vfi.inp 4,151 11-18-2019 14:30 be2dc604 cf_hs245c2c32g0s005vfi.out 506,968 11-19-2019 17:18 0e1c259b cf_hs245c2c32g0s010vfi.inp 4,151 11-18-2019 14:30 7867dc6b cf_hs245c2c32g0s010vfi.out 507,003 11-19-2019 17:16 d079a36b cf_hs245c2c32g0s030vfi.inp 4,151 11-18-2019 14:30 475b9ba5 cf_hs245c2c32g0s030vfi.out 507,070 11-19-2019 17:16 f986a788 cf_hs245c2c32g0s050vfi.inp 4,151 11-18-2019 14:31 bdb6bbc9 cf_hs245c2c32g0s050vfi.out 505,852 11-19-2019 17:24 b0952361 cf_hs245c2c32g0s070vfi.inp 4,151 11-18-2019 14:31 c5d5802c cf_hs245c2c32g0s070vfi.out 507,081 11-19-2019 17:55 5387b6ac cf_hs245c2c32g0s090vfi.inp 4,151 11-18-2019 14:31 e0fcb8bd cf_hs245c2c32g0s090vfi.out 507,131 11-19-2019 17:42 43722134 cf_hs245c2c32g0s095vfi.inp 4,151 11-18-2019 14:31 2af050f1 cf_hs245c2c32g0s095vfi.out 506,845 11-19-2019 17:46 dc83e28b cf_hs245c2c32g0s100vfi.inp 4,151 11-18-2019 14:31 c3fadbb0 cf_hs245c2c32g0s100vfi.out 507,195 11-19-2019 17:52 87bf1e0f
\\v1.2\\cf\\hs325\\ (18) 4,590,052 11-22-2019 12:48 cf_hs325c2c32g0s001vfi.inp 4,101 11-18-2019 12:43 d449e86f cf_hs325c2c32g0s001vfi.out 506,431 11-19-2019 12:08 24056923 cf_hs325c2c32g0s005vfi.inp 4,101 11-18-2019 12:43 aeada72f cf_hs325c2c32g0s005vfi.out 504,983 11-19-2019 11:41 10cd0e54 cf_hs325c2c32g0s010vfi.inp 4,101 11-18-2019 12:43 1c75fe73 cf_hs325c2c32g0s010vfi.out 505,578 11-19-2019 11:48 656d21bc cf_hs325c2c32g0s030vfi.inp 4,101 11-18-2019 12:43 e6e87090 cf_hs325c2c32g0s030vfi.out 507,121 11-19-2019 11:35 fb99157e cf_hs325c2c32g0s050vfi.inp 4,101 11-18-2019 12:43 5287baae cf_hs325c2c32g0s050vfi.out 506,070 11-19-2019 12:05 c0f5959a cf_hs325c2c32g0s070vfi.inp 4,101 11-18-2019 12:43 61fc62eb cf_hs325c2c32g0s070vfi.out 505,564 11-19-2019 12:03 bc68b1cb cf_hs325c2c32g0s090vfi.inp 4,101 11-18-2019 12:43 48a919cc cf_hs325c2c32g0s090vfi.out 504,857 11-19-2019 12:11 7abb568f
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
86 of 190 cf_hs325c2c32g0s095vfi.inp 4,101 11-18-2019 12:43 9bb1ab24 cf_hs325c2c32g0s095vfi.out 506,147 11-19-2019 12:13 00ffa06c cf_hs325c2c32g0s100vfi.inp 4,101 11-18-2019 12:43 babc6544 cf_hs325c2c32g0s100vfi.out 506,392 11-19-2019 12:23 b1241d5e
\\v1.2\\cf\\na245\\ (18) 5,914,706 11-22-2019 12:48 cf_na245c2c32g0s001vfio.inp 4,150 11-18-2019 11:20 26e6fae8 cf_na245c2c32g0s001vfio.out 652,477 11-19-2019 03:39 6a6effc0 cf_na245c2c32g0s005vfio.inp 4,150 11-18-2019 11:20 dcbfd286 cf_na245c2c32g0s005vfio.out 653,709 11-19-2019 03:35 119d76e2 cf_na245c2c32g0s010vfio.inp 4,150 11-18-2019 11:20 d75ee3f7 cf_na245c2c32g0s010vfio.out 652,970 11-19-2019 03:44 b7285fcd cf_na245c2c32g0s030vfio.inp 4,150 11-18-2019 11:20 4fd50594 cf_na245c2c32g0s030vfio.out 653,334 11-19-2019 04:18 0be1540b cf_na245c2c32g0s050vfio.inp 4,150 11-18-2019 11:20 c663fa0e cf_na245c2c32g0s050vfio.out 652,910 11-19-2019 04:33 48b9cb8f cf_na245c2c32g0s070vfio.inp 4,150 11-18-2019 11:20 a6b3b830 cf_na245c2c32g0s070vfio.out 653,593 11-19-2019 04:41 ba9ca416 cf_na245c2c32g0s090vfio.inp 4,150 11-18-2019 11:20 4f04c5bc cf_na245c2c32g0s090vfio.out 653,014 11-19-2019 04:49 94e3c6f5 cf_na245c2c32g0s095vfio.inp 4,150 11-18-2019 11:20 853d067d cf_na245c2c32g0s095vfio.out 653,201 11-19-2019 04:47 2d56d9fa cf_na245c2c32g0s100vfio.inp 4,150 11-18-2019 11:20 d9d13515 cf_na245c2c32g0s100vfio.out 652,148 11-19-2019 05:00 ecab220f
\\v1.2\\cf\\na325\\ (18) 5,909,929 11-22-2019 12:48 cf_na325c2c32g0s001vfio.inp 4,100 11-18-2019 10:17 0a0b0a34 cf_na325c2c32g0s001vfio.out 652,583 11-18-2019 19:51 6d6cb672 cf_na325c2c32g0s005vfio.inp 4,100 11-18-2019 10:17 1cad1fef cf_na325c2c32g0s005vfio.out 653,149 11-18-2019 19:39 36b5bd5e cf_na325c2c32g0s010vfio.inp 4,100 11-18-2019 10:17 dd891a1a cf_na325c2c32g0s010vfio.out 652,256 11-18-2019 19:55 0f738607 cf_na325c2c32g0s030vfio.inp 4,100 11-18-2019 10:17 47bc84fd cf_na325c2c32g0s030vfio.out 653,234 11-18-2019 20:23 707d814a cf_na325c2c32g0s050vfio.inp 4,100 11-18-2019 10:18 207e7681 cf_na325c2c32g0s050vfio.out 652,628 11-18-2019 20:53 02ca337f cf_na325c2c32g0s070vfio.inp 4,100 11-18-2019 10:18 14963815 cf_na325c2c32g0s070vfio.out 652,188 11-18-2019 21:03 0486ef45 cf_na325c2c32g0s090vfio.inp 4,100 11-18-2019 10:18 1f730962 cf_na325c2c32g0s090vfio.out 652,453 11-18-2019 21:07 07796cbc cf_na325c2c32g0s095vfio.inp 4,100 11-18-2019 10:18 5a07340c cf_na325c2c32g0s095vfio.out 652,299 11-18-2019 21:01 20de5516 cf_na325c2c32g0s100vfio.inp 4,100 11-18-2019 10:18 10655dde cf_na325c2c32g0s100vfio.out 652,239 11-18-2019 20:59 f52f8c68
\\v1.2\\cf\\ns245\\ (18) 4,598,284 11-22-2019 12:48 cf_ns245c2c32g0s001vfi.inp 4,151 11-18-2019 17:02 e9aaac77 cf_ns245c2c32g0s001vfi.out 506,261 11-20-2019 03:57 55be6b15 cf_ns245c2c32g0s005vfi.inp 4,151 11-18-2019 17:02 0b828027 cf_ns245c2c32g0s005vfi.out 506,151 11-20-2019 04:00 7babe822 cf_ns245c2c32g0s010vfi.inp 4,151 11-18-2019 17:02 cdc89a48 cf_ns245c2c32g0s010vfi.out 506,920 11-20-2019 03:50 624d1980 cf_ns245c2c32g0s030vfi.inp 4,151 11-18-2019 17:02 f2f4dd86 cf_ns245c2c32g0s030vfi.out 507,168 11-20-2019 04:12 1bb2a233 cf_ns245c2c32g0s050vfi.inp 4,151 11-18-2019 17:02 0819fdea cf_ns245c2c32g0s050vfi.out 507,105 11-20-2019 04:07 a4a2bc39 cf_ns245c2c32g0s070vfi.inp 4,151 11-18-2019 17:02 707ac60f cf_ns245c2c32g0s070vfi.out 506,684 11-20-2019 04:15 8bd5aaa8 cf_ns245c2c32g0s090vfi.inp 4,151 11-18-2019 17:03 5553fe9e cf_ns245c2c32g0s090vfi.out 506,470 11-20-2019 04:14 6159e9e2 cf_ns245c2c32g0s095vfi.inp 4,151 11-18-2019 17:03 9f5f16d2 cf_ns245c2c32g0s095vfi.out 506,818 11-20-2019 04:21 7ca1b78d cf_ns245c2c32g0s100vfi.inp 4,151 11-18-2019 17:03 76559d93 cf_ns245c2c32g0s100vfi.out 507,348 11-20-2019 04:24 750eb159
\\v1.2\\cf\\ns325\\ (18) 4,587,639 11-22-2019 12:48 cf_ns325c2c32g0s001vfi.inp 4,101 11-18-2019 15:58 3db326a4 cf_ns325c2c32g0s001vfi.out 506,184 11-19-2019 22:55 fe49500e cf_ns325c2c32g0s005vfi.inp 4,101 11-18-2019 15:58 475769e4 cf_ns325c2c32g0s005vfi.out 505,906 11-19-2019 22:28 2abe8907 cf_ns325c2c32g0s010vfi.inp 4,101 11-18-2019 15:58 f58f30b8 cf_ns325c2c32g0s010vfi.out 505,956 11-19-2019 22:31 31e748a5 cf_ns325c2c32g0s030vfi.inp 4,101 11-18-2019 15:58 0f12be5b cf_ns325c2c32g0s030vfi.out 505,068 11-19-2019 22:48 0068c972 cf_ns325c2c32g0s050vfi.inp 4,101 11-18-2019 15:58 bb7d7465 cf_ns325c2c32g0s050vfi.out 505,567 11-19-2019 22:52 358402f7 cf_ns325c2c32g0s070vfi.inp 4,101 11-18-2019 15:58 8806ac20
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
87 of 190 cf_ns325c2c32g0s070vfi.out 505,666 11-19-2019 23:01 528d3ca7 cf_ns325c2c32g0s090vfi.inp 4,101 11-18-2019 15:58 a153d707 cf_ns325c2c32g0s090vfi.out 505,631 11-19-2019 23:08 fc32d9c7 cf_ns325c2c32g0s095vfi.inp 4,101 11-18-2019 15:58 724b65ef cf_ns325c2c32g0s095vfi.out 505,699 11-19-2019 23:02 f5bf649b cf_ns325c2c32g0s100vfi.inp 4,101 11-18-2019 15:58 5346ab8f cf_ns325c2c32g0s100vfi.out 505,053 11-19-2019 23:25 ae94d221
\\v1.2\\da\\ (0) 161,490,353 11-18-2019 17:03
\\v1.2\\da\\ha245\\ (66) 20,112,628 11-18-2019 20:33 da_ha245a1c33g1s0500hx.inp 4,170 11-18-2019 02:06 c6eb48bb da_ha245a1c33g1s0500hx.out 654,027 11-18-2019 13:11 e184b5ad da_ha245a1c33g1s0600hx.inp 4,171 11-18-2019 02:07 8d713098 da_ha245a1c33g1s0600hx.out 654,456 11-18-2019 13:02 e98d3ed6 da_ha245a1c33g1s0700hx.inp 4,171 11-18-2019 02:07 7b7d0c18 da_ha245a1c33g1s0700hx.out 654,282 11-18-2019 13:01 d798d6aa da_ha245a1c33g1s0800hx.inp 4,171 11-18-2019 02:07 73faa350 da_ha245a1c33g1s0800hx.out 654,553 11-18-2019 13:06 30e18abc da_ha245a1c33g1s0900hx.inp 4,171 11-18-2019 02:07 99c1f9b1 da_ha245a1c33g1s0900hx.out 654,129 11-18-2019 12:58 e857f07d da_ha245a1c33g1s1000hx.inp 4,175 11-18-2019 02:07 6367a4cd da_ha245a1c33g1s1000hx.out 653,916 11-18-2019 13:00 f0be2e98 da_ha245a1c33g1s1100hx.inp 4,175 11-18-2019 02:07 02f07f78 da_ha245a1c33g1s1100hx.out 653,765 11-18-2019 13:08 46d048a5 da_ha245a1c33g1s1200hx.inp 4,175 11-18-2019 02:07 e53ec311 da_ha245a1c33g1s1200hx.out 654,157 11-18-2019 12:58 67079541 da_ha245a1c33g1s1300hx.inp 4,175 11-18-2019 02:07 84cd8409 da_ha245a1c33g1s1300hx.out 654,275 11-18-2019 13:01 187025db da_ha245a1c33g1s1400hx.inp 4,175 11-18-2019 02:07 690e5283 da_ha245a1c33g1s1400hx.out 654,548 11-18-2019 13:09 618b56b8 da_ha245a1c33g1s1500hx.inp 4,175 11-18-2019 02:07 642882a3 da_ha245a1c33g1s1500hx.out 655,105 11-18-2019 13:03 bd8b0d5f da_ha245a1c33g2s0500hx.inp 4,168 11-18-2019 02:07 0febc1f5 da_ha245a1c33g2s0500hx.out 507,140 11-18-2019 13:45 1299ccda da_ha245a1c33g2s0600hx.inp 4,169 11-18-2019 02:08 d0558fa3 da_ha245a1c33g2s0600hx.out 507,859 11-18-2019 13:45 46f4eb01 da_ha245a1c33g2s0700hx.inp 4,169 11-18-2019 02:08 ecc40822 da_ha245a1c33g2s0700hx.out 508,085 11-18-2019 13:33 7aa0acd2 da_ha245a1c33g2s0800hx.inp 4,169 11-18-2019 02:08 5a9930ca da_ha245a1c33g2s0800hx.out 507,599 11-18-2019 13:32 950728b7 da_ha245a1c33g2s0900hx.inp 4,169 11-18-2019 02:08 fcea8290 da_ha245a1c33g2s0900hx.out 507,486 11-18-2019 13:38 d6e830bb da_ha245a1c33g2s1000hx.inp 4,173 11-18-2019 02:08 6f5bd21f da_ha245a1c33g2s1000hx.out 507,307 11-18-2019 13:29 acedbc43 da_ha245a1c33g2s1100hx.inp 4,173 11-18-2019 02:08 ad67c1e7 da_ha245a1c33g2s1100hx.out 507,692 11-18-2019 13:29 c9ed4a27 da_ha245a1c33g2s1200hx.inp 4,173 11-18-2019 02:08 33e86204 da_ha245a1c33g2s1200hx.out 508,497 11-18-2019 13:36 c0873868 da_ha245a1c33g2s1300hx.inp 4,173 11-18-2019 02:08 03485648 da_ha245a1c33g2s1300hx.out 506,792 11-18-2019 13:29 944de814 da_ha245a1c33g2s1400hx.inp 4,173 11-18-2019 02:08 80612e35 da_ha245a1c33g2s1400hx.out 508,116 11-18-2019 13:29 047c7c71 da_ha245a1c33g2s1500hx.inp 4,173 11-18-2019 02:08 ddf94020 da_ha245a1c33g2s1500hx.out 507,100 11-18-2019 13:36 fe66dbe8 da_ha245a1c33g3s0500hx.inp 4,165 11-18-2019 02:08 427cd948 da_ha245a1c33g3s0500hx.out 653,531 11-18-2019 13:21 a418c278 da_ha245a1c33g3s0600hx.inp 4,166 11-18-2019 02:08 5a09fe9e da_ha245a1c33g3s0600hx.out 654,348 11-18-2019 13:17 fb5d9c73 da_ha245a1c33g3s0700hx.inp 4,166 11-18-2019 02:09 4a379c85 da_ha245a1c33g3s0700hx.out 654,303 11-18-2019 13:24 5d5bf37b da_ha245a1c33g3s0800hx.inp 4,166 11-18-2019 02:09 06699666 da_ha245a1c33g3s0800hx.out 654,334 11-18-2019 13:12 5dac3273 da_ha245a1c33g3s0900hx.inp 4,166 11-18-2019 02:09 1d7b5fee da_ha245a1c33g3s0900hx.out 653,703 11-18-2019 13:10 0daf1109 da_ha245a1c33g3s1000hx.inp 4,170 11-18-2019 02:09 e31d1f97 da_ha245a1c33g3s1000hx.out 654,617 11-18-2019 13:11 ae284b22 da_ha245a1c33g3s1100hx.inp 4,170 11-18-2019 02:09 2900854a da_ha245a1c33g3s1100hx.out 653,869 11-18-2019 13:10 b636a64c da_ha245a1c33g3s1200hx.inp 4,170 11-18-2019 02:09 eb4c9650 da_ha245a1c33g3s1200hx.out 653,905 11-18-2019 13:11 8622ccb3 da_ha245a1c33g3s1300hx.inp 4,170 11-18-2019 02:09 85fc7846 da_ha245a1c33g3s1300hx.out 653,456 11-18-2019 13:11 fb483a07 da_ha245a1c33g3s1400hx.inp 4,170 11-18-2019 02:09 4f1df332 da_ha245a1c33g3s1400hx.out 653,793 11-18-2019 13:12 3a65ba99 da_ha245a1c33g3s1500hx.inp 4,170 11-18-2019 02:09 e16d6571 da_ha245a1c33g3s1500hx.out 654,248 11-18-2019 13:13 45a966f8
\\v1.2\\da\\ha325\\ (66) 20,807,639 11-18-2019 20:33
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
88 of 190 da_ha325a1c33g1s0500hx.inp 4,116 11-18-2019 00:13 02e2c08d da_ha325a1c33g1s0500hx.out 652,924 11-18-2019 03:30 d26a3373 da_ha325a1c33g1s0600hx.inp 4,116 11-18-2019 00:13 7bb73ad1 da_ha325a1c33g1s0600hx.out 653,646 11-18-2019 03:24 a01a3570 da_ha325a1c33g1s0700hx.inp 4,116 11-18-2019 00:13 2b8f48dd da_ha325a1c33g1s0700hx.out 653,313 11-18-2019 03:24 e8f8e96b da_ha325a1c33g1s0800hx.inp 4,116 11-18-2019 00:13 531a61c4 da_ha325a1c33g1s0800hx.out 653,835 11-18-2019 03:24 bf869414 da_ha325a1c33g1s0900hx.inp 4,116 11-18-2019 00:13 42512bc4 da_ha325a1c33g1s0900hx.out 652,638 11-18-2019 03:21 3d4f3beb da_ha325a1c33g1s1000hx.inp 4,120 11-18-2019 00:13 76534103 da_ha325a1c33g1s1000hx.out 653,142 11-18-2019 03:23 67258c3c da_ha325a1c33g1s1100hx.inp 4,120 11-18-2019 00:14 046b2fcb da_ha325a1c33g1s1100hx.out 652,898 11-18-2019 03:25 6b444f61 da_ha325a1c33g1s1200hx.inp 4,120 11-18-2019 00:14 72af064d da_ha325a1c33g1s1200hx.out 654,694 11-18-2019 03:23 5534733a da_ha325a1c33g1s1300hx.inp 4,120 11-18-2019 00:14 c1f7c906 da_ha325a1c33g1s1300hx.out 653,302 11-18-2019 03:23 844285c2 da_ha325a1c33g1s1400hx.inp 4,120 11-18-2019 00:14 e131880b da_ha325a1c33g1s1400hx.out 653,106 11-18-2019 03:27 833faae6 da_ha325a1c33g1s1500hx.inp 4,119 11-18-2019 00:14 152d11d9 da_ha325a1c33g1s1500hx.out 652,807 11-18-2019 03:26 732ebb44 da_ha325a1c33g2s0500hx.inp 4,114 11-18-2019 00:14 2fef597a da_ha325a1c33g2s0500hx.out 506,466 11-18-2019 04:06 c20978ab da_ha325a1c33g2s0600hx.inp 4,114 11-18-2019 00:14 304fe968 da_ha325a1c33g2s0600hx.out 506,420 11-18-2019 04:04 132264f2 da_ha325a1c33g2s0700hx.inp 4,114 11-18-2019 00:14 e4a88a05 da_ha325a1c33g2s0700hx.out 506,161 11-18-2019 03:57 9c14dcf2 da_ha325a1c33g2s0800hx.inp 4,114 11-18-2019 00:14 90730a4e da_ha325a1c33g2s0800hx.out 506,414 11-18-2019 03:54 1bf7beea da_ha325a1c33g2s0900hx.inp 4,114 11-18-2019 00:14 e33a2297 da_ha325a1c33g2s0900hx.out 507,426 11-18-2019 03:55 ecec1bd7 da_ha325a1c33g2s1000hx.inp 4,118 11-18-2019 00:14 5824f9ec da_ha325a1c33g2s1000hx.out 506,440 11-18-2019 03:50 26c0a678 da_ha325a1c33g2s1100hx.inp 4,118 11-18-2019 00:14 0728016e da_ha325a1c33g2s1100hx.out 652,220 11-18-2019 03:53 944e1ec4 da_ha325a1c33g2s1200hx.inp 4,118 11-18-2019 00:15 ac99a34b da_ha325a1c33g2s1200hx.out 652,613 11-18-2019 03:51 ec4eaf1b da_ha325a1c33g2s1300hx.inp 4,118 11-18-2019 00:15 d9b19ddf da_ha325a1c33g2s1300hx.out 654,878 11-18-2019 03:48 543bd345 da_ha325a1c33g2s1400hx.inp 4,118 11-18-2019 00:15 b443a8db da_ha325a1c33g2s1400hx.out 652,825 11-18-2019 03:49 dd4625da da_ha325a1c33g2s1500hx.inp 4,118 11-18-2019 00:15 18000a33 da_ha325a1c33g2s1500hx.out 653,498 11-18-2019 03:52 492919c9 da_ha325a1c33g3s0500hx.inp 4,111 11-18-2019 00:15 9184dfe7 da_ha325a1c33g3s0500hx.out 652,536 11-18-2019 03:42 1c5a9665 da_ha325a1c33g3s0600hx.inp 4,111 11-18-2019 00:15 d8a6d593 da_ha325a1c33g3s0600hx.out 653,772 11-18-2019 03:42 220a3805 da_ha325a1c33g3s0700hx.inp 4,111 11-18-2019 00:15 421fe78a da_ha325a1c33g3s0700hx.out 652,688 11-18-2019 03:40 21fcf5b6 da_ha325a1c33g3s0800hx.inp 4,111 11-18-2019 00:15 56c51d89 da_ha325a1c33g3s0800hx.out 652,354 11-18-2019 03:36 3a96155e da_ha325a1c33g3s0900hx.inp 4,111 11-18-2019 00:15 b24c2510 da_ha325a1c33g3s0900hx.out 652,743 11-18-2019 03:30 f2c504c9 da_ha325a1c33g3s1000hx.inp 4,115 11-18-2019 00:15 e8802e00 da_ha325a1c33g3s1000hx.out 652,906 11-18-2019 03:35 b30b4dff da_ha325a1c33g3s1100hx.inp 4,115 11-18-2019 00:15 b4ebe41b da_ha325a1c33g3s1100hx.out 652,310 11-18-2019 03:36 3f10b650 da_ha325a1c33g3s1200hx.inp 4,115 11-18-2019 00:15 9e5378d2 da_ha325a1c33g3s1200hx.out 652,522 11-18-2019 03:37 91ac71cf da_ha325a1c33g3s1300hx.inp 4,115 11-18-2019 00:15 501e8f78 da_ha325a1c33g3s1300hx.out 652,834 11-18-2019 03:37 b4515ba2 da_ha325a1c33g3s1400hx.inp 4,115 11-18-2019 00:16 c03bae68 da_ha325a1c33g3s1400hx.out 652,595 11-18-2019 03:37 ccc53075 da_ha325a1c33g3s1500hx.inp 4,114 11-18-2019 00:16 2d052685 da_ha325a1c33g3s1500hx.out 652,892 11-18-2019 03:39 457d5404
\\v1.2\\da\\hs245\\ (66) 20,112,785 11-20-2019 09:22 da_hs245a1c33g1s0500hx.inp 4,198 11-18-2019 14:31 6611cb60 da_hs245a1c33g1s0500hx.out 654,316 11-19-2019 18:03 1cfa0260 da_hs245a1c33g1s0600hx.inp 4,199 11-18-2019 14:31 e85a30b5 da_hs245a1c33g1s0600hx.out 654,332 11-19-2019 18:17 88c70da2 da_hs245a1c33g1s0700hx.inp 4,199 11-18-2019 14:31 09c77296 da_hs245a1c33g1s0700hx.out 653,138 11-19-2019 17:58 3a8cd11c da_hs245a1c33g1s0800hx.inp 4,199 11-18-2019 14:31 f348116b da_hs245a1c33g1s0800hx.out 654,502 11-19-2019 17:57 5ea32cc2 da_hs245a1c33g1s0900hx.inp 4,199 11-18-2019 14:31 c3eb1e9b da_hs245a1c33g1s0900hx.out 653,772 11-19-2019 18:01 ffa7a3b4 da_hs245a1c33g1s1000hx.inp 4,203 11-18-2019 14:32 d0fee515
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
89 of 190 da_hs245a1c33g1s1000hx.out 654,558 11-19-2019 18:13 5300fd8e da_hs245a1c33g1s1100hx.inp 4,203 11-18-2019 14:32 091a8f2a da_hs245a1c33g1s1100hx.out 654,179 11-19-2019 18:06 a207ca17 da_hs245a1c33g1s1200hx.inp 4,203 11-18-2019 14:32 4b80f82c da_hs245a1c33g1s1200hx.out 653,906 11-19-2019 18:00 cff09b26 da_hs245a1c33g1s1300hx.inp 4,203 11-18-2019 14:32 5803fec2 da_hs245a1c33g1s1300hx.out 654,974 11-19-2019 18:03 56d333e7 da_hs245a1c33g1s1400hx.inp 4,203 11-18-2019 14:32 475e8805 da_hs245a1c33g1s1400hx.out 653,869 11-19-2019 18:07 9b134966 da_hs245a1c33g1s1500hx.inp 4,203 11-18-2019 14:32 8436e38b da_hs245a1c33g1s1500hx.out 654,132 11-19-2019 18:07 ad7a9de8 da_hs245a1c33g2s0500hx.inp 4,196 11-18-2019 14:32 a611c470 da_hs245a1c33g2s0500hx.out 507,600 11-19-2019 18:54 493fc7ae da_hs245a1c33g2s0600hx.inp 4,197 11-18-2019 14:32 a945f9fa da_hs245a1c33g2s0600hx.out 507,229 11-19-2019 18:39 aa22ed17 da_hs245a1c33g2s0700hx.inp 4,197 11-18-2019 14:32 3c022b53 da_hs245a1c33g2s0700hx.out 507,421 11-19-2019 18:37 47493db0 da_hs245a1c33g2s0800hx.inp 4,197 11-18-2019 14:32 78e876e9 da_hs245a1c33g2s0800hx.out 506,815 11-19-2019 18:37 052b7fa2 da_hs245a1c33g2s0900hx.inp 4,197 11-18-2019 14:32 eb831c22 da_hs245a1c33g2s0900hx.out 507,747 11-19-2019 18:35 042df630 da_hs245a1c33g2s1000hx.inp 4,201 11-18-2019 14:32 db3dc087 da_hs245a1c33g2s1000hx.out 506,446 11-19-2019 18:35 3a204169 da_hs245a1c33g2s1100hx.inp 4,201 11-18-2019 14:33 07cb1d4a da_hs245a1c33g2s1100hx.out 507,600 11-19-2019 18:33 e3991621 da_hs245a1c33g2s1200hx.inp 4,201 11-18-2019 14:33 ff005d32 da_hs245a1c33g2s1200hx.out 507,748 11-19-2019 18:46 3c3b7e75 da_hs245a1c33g2s1300hx.inp 4,201 11-18-2019 14:33 393ec593 da_hs245a1c33g2s1300hx.out 508,267 11-19-2019 18:31 5e2a330a da_hs245a1c33g2s1400hx.inp 4,201 11-18-2019 14:33 b2ecc3c0 da_hs245a1c33g2s1400hx.out 508,378 11-19-2019 18:31 327a0358 da_hs245a1c33g2s1500hx.inp 4,201 11-18-2019 14:33 fac79977 da_hs245a1c33g2s1500hx.out 507,412 11-19-2019 18:35 3c01f6c8 da_hs245a1c33g3s0500hx.inp 4,193 11-18-2019 14:33 26955d38 da_hs245a1c33g3s0500hx.out 654,199 11-19-2019 18:27 8f0bec3d da_hs245a1c33g3s0600hx.inp 4,194 11-18-2019 14:33 e32f1dd5 da_hs245a1c33g3s0600hx.out 653,669 11-19-2019 18:21 8eba26ba da_hs245a1c33g3s0700hx.inp 4,194 11-18-2019 14:33 d5a8e6ed da_hs245a1c33g3s0700hx.out 654,278 11-19-2019 18:26 ec706f2b da_hs245a1c33g3s0800hx.inp 4,194 11-18-2019 14:33 a0803ea3 da_hs245a1c33g3s0800hx.out 653,803 11-19-2019 18:09 efecbc00 da_hs245a1c33g3s0900hx.inp 4,194 11-18-2019 14:33 3904bb7b da_hs245a1c33g3s0900hx.out 653,984 11-19-2019 18:18 f35f62e0 da_hs245a1c33g3s1000hx.inp 4,198 11-18-2019 14:33 2268594f da_hs245a1c33g3s1000hx.out 655,227 11-19-2019 18:20 47f6520c da_hs245a1c33g3s1100hx.inp 4,198 11-18-2019 14:34 4e4562b1 da_hs245a1c33g3s1100hx.out 654,423 11-19-2019 18:28 3ba8a54f da_hs245a1c33g3s1200hx.inp 4,198 11-18-2019 14:34 cee4ce78 da_hs245a1c33g3s1200hx.out 653,771 11-19-2019 18:20 6fe27200 da_hs245a1c33g3s1300hx.inp 4,198 11-18-2019 14:34 70133d5c da_hs245a1c33g3s1300hx.out 654,120 11-19-2019 18:31 bdce5848 da_hs245a1c33g3s1400hx.inp 4,198 11-18-2019 14:34 499c3975 da_hs245a1c33g3s1400hx.out 654,099 11-19-2019 18:21 fcd1dc7d da_hs245a1c33g3s1500hx.inp 4,198 11-18-2019 14:34 f5225108 da_hs245a1c33g3s1500hx.out 654,312 11-19-2019 18:31 d0cd7818
\\v1.2\\da\\hs325\\ (66) 20,075,727 11-20-2019 09:22 da_hs325a1c33g1s0500hx.inp 4,149 11-18-2019 12:44 b89da89b da_hs325a1c33g1s0500hx.out 653,166 11-19-2019 12:23 74ecbed1 da_hs325a1c33g1s0600hx.inp 4,149 11-18-2019 12:44 db229fc5 da_hs325a1c33g1s0600hx.out 653,023 11-19-2019 12:41 53ea80ab da_hs325a1c33g1s0700hx.inp 4,149 11-18-2019 12:44 df689cef da_hs325a1c33g1s0700hx.out 653,837 11-19-2019 12:29 f129a931 da_hs325a1c33g1s0800hx.inp 4,149 11-18-2019 12:44 9ceeb7eb da_hs325a1c33g1s0800hx.out 652,771 11-19-2019 12:42 2ed9081d da_hs325a1c33g1s0900hx.inp 4,149 11-18-2019 12:44 9111cbbc da_hs325a1c33g1s0900hx.out 653,338 11-19-2019 12:33 e5cb29cb da_hs325a1c33g1s1000hx.inp 4,153 11-18-2019 12:44 360c18aa da_hs325a1c33g1s1000hx.out 653,400 11-19-2019 12:24 fa8eae15 da_hs325a1c33g1s1100hx.inp 4,153 11-18-2019 12:44 d8fdd78c da_hs325a1c33g1s1100hx.out 653,946 11-19-2019 12:24 ad9789bf da_hs325a1c33g1s1200hx.inp 4,153 11-18-2019 12:44 e558f78f da_hs325a1c33g1s1200hx.out 652,901 11-19-2019 12:35 e740fd33 da_hs325a1c33g1s1300hx.inp 4,153 11-18-2019 12:44 2d6ff228 da_hs325a1c33g1s1300hx.out 652,970 11-19-2019 12:46 bf73976b da_hs325a1c33g1s1400hx.inp 4,153 11-18-2019 12:44 d5e7b97f da_hs325a1c33g1s1400hx.out 653,367 11-19-2019 12:37 ca0ab428 da_hs325a1c33g1s1500hx.inp 4,152 11-18-2019 12:44 58d745b9 da_hs325a1c33g1s1500hx.out 652,506 11-19-2019 12:31 a76a9892 da_hs325a1c33g2s0500hx.inp 4,147 11-18-2019 12:44 cfe88cc5
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
90 of 190 da_hs325a1c33g2s0500hx.out 506,757 11-19-2019 13:24 fa47dcf8 da_hs325a1c33g2s0600hx.inp 4,147 11-18-2019 12:45 93cf9646 da_hs325a1c33g2s0600hx.out 506,773 11-19-2019 13:16 aa2e9e43 da_hs325a1c33g2s0700hx.inp 4,147 11-18-2019 12:45 5d38a221 da_hs325a1c33g2s0700hx.out 506,357 11-19-2019 13:20 dccb4ca5 da_hs325a1c33g2s0800hx.inp 4,147 11-18-2019 12:45 af1b9df3 da_hs325a1c33g2s0800hx.out 506,519 11-19-2019 13:18 f2300841 da_hs325a1c33g2s0900hx.inp 4,147 11-18-2019 12:45 375c2172 da_hs325a1c33g2s0900hx.out 506,540 11-19-2019 13:17 b7ca3c0b da_hs325a1c33g2s1000hx.inp 4,151 11-18-2019 12:45 143d91a9 da_hs325a1c33g2s1000hx.out 505,264 11-19-2019 13:29 fe5cc649 da_hs325a1c33g2s1100hx.inp 4,151 11-18-2019 12:45 e9c8cd83 da_hs325a1c33g2s1100hx.out 507,191 11-19-2019 13:05 2e532b62 da_hs325a1c33g2s1200hx.inp 4,151 11-18-2019 12:45 c2eaa03d da_hs325a1c33g2s1200hx.out 506,946 11-19-2019 13:16 a9370707 da_hs325a1c33g2s1300hx.inp 4,151 11-18-2019 12:45 3a2b5bf2 da_hs325a1c33g2s1300hx.out 506,698 11-19-2019 13:26 d815f69e da_hs325a1c33g2s1400hx.inp 4,151 11-18-2019 12:45 ec3126d4 da_hs325a1c33g2s1400hx.out 506,368 11-19-2019 13:21 5b72fcab da_hs325a1c33g2s1500hx.inp 4,151 11-18-2019 12:45 bc967a8e da_hs325a1c33g2s1500hx.out 505,833 11-19-2019 13:19 c75281d5 da_hs325a1c33g3s0500hx.inp 4,144 11-18-2019 12:45 6cc80da7 da_hs325a1c33g3s0500hx.out 653,004 11-19-2019 13:14 5d176f2c da_hs325a1c33g3s0600hx.inp 4,144 11-18-2019 12:46 f767cd02 da_hs325a1c33g3s0600hx.out 652,479 11-19-2019 13:12 ea533555 da_hs325a1c33g3s0700hx.inp 4,144 11-18-2019 12:46 721de28e da_hs325a1c33g3s0700hx.out 652,107 11-19-2019 13:00 58d54eb0 da_hs325a1c33g3s0800hx.inp 4,144 11-18-2019 12:46 781272d8 da_hs325a1c33g3s0800hx.out 653,168 11-19-2019 13:09 37926bc2 da_hs325a1c33g3s0900hx.inp 4,144 11-18-2019 12:46 91e51402 da_hs325a1c33g3s0900hx.out 652,573 11-19-2019 13:10 140a9f5b da_hs325a1c33g3s1000hx.inp 4,148 11-18-2019 12:46 fc12edcb da_hs325a1c33g3s1000hx.out 653,073 11-19-2019 13:09 23a4caf2 da_hs325a1c33g3s1100hx.inp 4,148 11-18-2019 12:46 12b16926 da_hs325a1c33g3s1100hx.out 654,101 11-19-2019 13:01 afb35b87 da_hs325a1c33g3s1200hx.inp 4,148 11-18-2019 12:46 f3b941d6 da_hs325a1c33g3s1200hx.out 652,739 11-19-2019 13:13 549d2c44 da_hs325a1c33g3s1300hx.inp 4,148 11-18-2019 12:46 352efa01 da_hs325a1c33g3s1300hx.out 653,481 11-19-2019 13:15 bfd0a087 da_hs325a1c33g3s1400hx.inp 4,148 11-18-2019 12:46 0b1374d6 da_hs325a1c33g3s1400hx.out 652,844 11-19-2019 13:12 9291fe63 da_hs325a1c33g3s1500hx.inp 4,147 11-18-2019 12:46 570718b6 da_hs325a1c33g3s1500hx.out 652,777 11-19-2019 13:22 4054dd70
\\v1.2\\da\\na245\\ (66) 20,111,437 11-20-2019 09:22 da_na245a1c33g1s0500hx.inp 4,197 11-18-2019 11:20 69eca0ea da_na245a1c33g1s0500hx.out 654,064 11-19-2019 04:59 0bb38534 da_na245a1c33g1s0600hx.inp 4,198 11-18-2019 11:21 977fab06 da_na245a1c33g1s0600hx.out 654,331 11-19-2019 04:55 ccc57877 da_na245a1c33g1s0700hx.inp 4,198 11-18-2019 11:21 5fabf9fb da_na245a1c33g1s0700hx.out 653,447 11-19-2019 04:55 4c08901b da_na245a1c33g1s0800hx.inp 4,198 11-18-2019 11:21 ee8b6d5c da_na245a1c33g1s0800hx.out 654,460 11-19-2019 04:55 c3ab25a2 da_na245a1c33g1s0900hx.inp 4,198 11-18-2019 11:21 f18dd3ad da_na245a1c33g1s0900hx.out 654,810 11-19-2019 04:54 af024ff4 da_na245a1c33g1s1000hx.inp 4,202 11-18-2019 11:21 271a443e da_na245a1c33g1s1000hx.out 653,864 11-19-2019 05:00 cac51e73 da_na245a1c33g1s1100hx.inp 4,202 11-18-2019 11:21 f265ec0f da_na245a1c33g1s1100hx.out 654,497 11-19-2019 04:56 d756c4d4 da_na245a1c33g1s1200hx.inp 4,202 11-18-2019 11:21 f1ccafff da_na245a1c33g1s1200hx.out 654,118 11-19-2019 05:06 4be15141 da_na245a1c33g1s1300hx.inp 4,202 11-18-2019 11:21 787a0246 da_na245a1c33g1s1300hx.out 654,137 11-19-2019 05:03 2f064917 da_na245a1c33g1s1400hx.inp 4,202 11-18-2019 11:21 865755c9 da_na245a1c33g1s1400hx.out 653,704 11-19-2019 05:02 fe99d277 da_na245a1c33g1s1500hx.inp 4,202 11-18-2019 11:21 c875c5de da_na245a1c33g1s1500hx.out 653,461 11-19-2019 05:12 b643f54f da_na245a1c33g2s0500hx.inp 4,195 11-18-2019 11:22 a73609fc da_na245a1c33g2s0500hx.out 507,752 11-19-2019 05:41 60eabc89 da_na245a1c33g2s0600hx.inp 4,196 11-18-2019 11:22 122c2643 da_na245a1c33g2s0600hx.out 507,171 11-19-2019 05:37 33eec119 da_na245a1c33g2s0700hx.inp 4,196 11-18-2019 11:22 51367bfd da_na245a1c33g2s0700hx.out 506,894 11-19-2019 05:35 d8fc6440 da_na245a1c33g2s0800hx.inp 4,196 11-18-2019 11:22 69909e2b da_na245a1c33g2s0800hx.out 509,141 11-19-2019 05:48 0f0d012b da_na245a1c33g2s0900hx.inp 4,196 11-18-2019 11:22 37c8985d da_na245a1c33g2s0900hx.out 507,744 11-19-2019 05:30 acf698f1 da_na245a1c33g2s1000hx.inp 4,200 11-18-2019 11:22 48c94595 da_na245a1c33g2s1000hx.out 508,078 11-19-2019 05:32 059f30f2 da_na245a1c33g2s1100hx.inp 4,200 11-18-2019 11:22 244db8e5
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
91 of 190 da_na245a1c33g2s1100hx.out 507,175 11-19-2019 05:38 9ac62641 da_na245a1c33g2s1200hx.inp 4,200 11-18-2019 11:22 8c926995 da_na245a1c33g2s1200hx.out 507,736 11-19-2019 05:33 daba2b89 da_na245a1c33g2s1300hx.inp 4,200 11-18-2019 11:22 e05960c3 da_na245a1c33g2s1300hx.out 508,706 11-19-2019 05:30 9f3aee35 da_na245a1c33g2s1400hx.inp 4,200 11-18-2019 11:22 72d7c1e8 da_na245a1c33g2s1400hx.out 507,583 11-19-2019 05:38 1749ecd5 da_na245a1c33g2s1500hx.inp 4,200 11-18-2019 11:22 5bf62ce8 da_na245a1c33g2s1500hx.out 506,736 11-19-2019 05:37 926b7eb0 da_na245a1c33g3s0500hx.inp 4,192 11-18-2019 11:23 c7aae954 da_na245a1c33g3s0500hx.out 653,664 11-19-2019 05:27 24bfd557 da_na245a1c33g3s0600hx.inp 4,193 11-18-2019 11:23 478ab468 da_na245a1c33g3s0600hx.out 653,321 11-19-2019 05:30 b552355d da_na245a1c33g3s0700hx.inp 4,193 11-18-2019 11:23 9dba419a da_na245a1c33g3s0700hx.out 653,978 11-19-2019 05:29 36f6e70b da_na245a1c33g3s0800hx.inp 4,193 11-18-2019 11:23 f28f46f9 da_na245a1c33g3s0800hx.out 653,762 11-19-2019 05:19 8ca9cc0d da_na245a1c33g3s0900hx.inp 4,193 11-18-2019 11:23 371beaf6 da_na245a1c33g3s0900hx.out 653,942 11-19-2019 05:22 cd4a46a6 da_na245a1c33g3s1000hx.inp 4,197 11-18-2019 11:23 e0e99e63 da_na245a1c33g3s1000hx.out 653,577 11-19-2019 05:18 ecdb319a da_na245a1c33g3s1100hx.inp 4,197 11-18-2019 11:23 221656e8 da_na245a1c33g3s1100hx.out 654,380 11-19-2019 05:39 54e88e4b da_na245a1c33g3s1200hx.inp 4,197 11-18-2019 11:23 a8785da8 da_na245a1c33g3s1200hx.out 654,045 11-19-2019 05:32 91ab9bdf da_na245a1c33g3s1300hx.inp 4,197 11-18-2019 11:23 f6760040 da_na245a1c33g3s1300hx.out 654,509 11-19-2019 05:21 93014acc da_na245a1c33g3s1400hx.inp 4,197 11-18-2019 11:23 0a2dc9a3 da_na245a1c33g3s1400hx.out 653,867 11-19-2019 05:33 7bfcc020 da_na245a1c33g3s1500hx.inp 4,197 11-18-2019 11:23 1517c3c4 da_na245a1c33g3s1500hx.out 654,257 11-19-2019 05:40 b772bade
\\v1.2\\da\\na325\\ (66) 20,082,255 11-20-2019 09:22 da_na325a1c33g1s0500hx.inp 4,148 11-18-2019 10:18 46c677bc da_na325a1c33g1s0500hx.out 653,326 11-18-2019 21:16 b793c597 da_na325a1c33g1s0600hx.inp 4,148 11-18-2019 10:18 a705f91a da_na325a1c33g1s0600hx.out 653,530 11-18-2019 21:17 c5781d3d da_na325a1c33g1s0700hx.inp 4,148 11-18-2019 10:18 e8703396 da_na325a1c33g1s0700hx.out 653,209 11-18-2019 21:19 739526ba da_na325a1c33g1s0800hx.inp 4,148 11-18-2019 10:18 ff8e9440 da_na325a1c33g1s0800hx.out 652,573 11-18-2019 21:10 38b04b99 da_na325a1c33g1s0900hx.inp 4,148 11-18-2019 10:18 5893fc12 da_na325a1c33g1s0900hx.out 653,264 11-18-2019 21:13 c60ca9ce da_na325a1c33g1s1000hx.inp 4,152 11-18-2019 10:18 bedf929f da_na325a1c33g1s1000hx.out 653,293 11-18-2019 21:22 caf289b8 da_na325a1c33g1s1100hx.inp 4,152 11-18-2019 10:19 c989a49e da_na325a1c33g1s1100hx.out 654,133 11-18-2019 21:35 7c8edfff da_na325a1c33g1s1200hx.inp 4,152 11-18-2019 10:19 f364f6c3 da_na325a1c33g1s1200hx.out 653,358 11-18-2019 21:17 8f43ab08 da_na325a1c33g1s1300hx.inp 4,152 11-18-2019 10:19 6d1d9e25 da_na325a1c33g1s1300hx.out 652,163 11-18-2019 21:18 df574b1d da_na325a1c33g1s1400hx.inp 4,152 11-18-2019 10:19 5baf2b9d da_na325a1c33g1s1400hx.out 653,717 11-18-2019 21:08 1608a210 da_na325a1c33g1s1500hx.inp 4,151 11-18-2019 10:19 d6cfad8a da_na325a1c33g1s1500hx.out 653,724 11-18-2019 21:22 bc3ee54f da_na325a1c33g2s0500hx.inp 4,146 11-18-2019 10:19 ec82d98c da_na325a1c33g2s0500hx.out 506,574 11-18-2019 22:01 6b874d42 da_na325a1c33g2s0600hx.inp 4,146 11-18-2019 10:19 a34958f2 da_na325a1c33g2s0600hx.out 506,550 11-18-2019 21:46 5e3e3c9d da_na325a1c33g2s0700hx.inp 4,146 11-18-2019 10:19 9e996094 da_na325a1c33g2s0700hx.out 506,908 11-18-2019 21:57 41159d1d da_na325a1c33g2s0800hx.inp 4,146 11-18-2019 10:19 a8a5e0f5 da_na325a1c33g2s0800hx.out 508,429 11-18-2019 21:51 a72b52fd da_na325a1c33g2s0900hx.inp 4,146 11-18-2019 10:19 617c1ec3 da_na325a1c33g2s0900hx.out 507,248 11-18-2019 22:04 ce180c2a da_na325a1c33g2s1000hx.inp 4,150 11-18-2019 10:19 323c89d0 da_na325a1c33g2s1000hx.out 506,418 11-18-2019 21:48 bc5b2e8d da_na325a1c33g2s1100hx.inp 4,150 11-18-2019 10:20 09ec51c5 da_na325a1c33g2s1100hx.out 506,713 11-18-2019 21:50 72a80867 da_na325a1c33g2s1200hx.inp 4,150 11-18-2019 10:20 16d3b40a da_na325a1c33g2s1200hx.out 506,555 11-18-2019 21:40 eedd592c da_na325a1c33g2s1300hx.inp 4,150 11-18-2019 10:20 f2bcca69 da_na325a1c33g2s1300hx.out 507,963 11-18-2019 21:58 102855c7 da_na325a1c33g2s1400hx.inp 4,150 11-18-2019 10:20 13f957ba da_na325a1c33g2s1400hx.out 506,868 11-18-2019 21:52 19418ab0 da_na325a1c33g2s1500hx.inp 4,150 11-18-2019 10:20 67f1fd03 da_na325a1c33g2s1500hx.out 506,079 11-18-2019 21:50 6951f9c0 da_na325a1c33g3s0500hx.inp 4,143 11-18-2019 10:20 b1a5b7d8 da_na325a1c33g3s0500hx.out 652,890 11-18-2019 22:04 f3a01c0e da_na325a1c33g3s0600hx.inp 4,143 11-18-2019 10:20 1a4ab816
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
92 of 190 da_na325a1c33g3s0600hx.out 652,979 11-18-2019 21:41 4ad62ec1 da_na325a1c33g3s0700hx.inp 4,143 11-18-2019 10:20 8659cf7a da_na325a1c33g3s0700hx.out 654,361 11-18-2019 21:42 c1c1f0e2 da_na325a1c33g3s0800hx.inp 4,143 11-18-2019 10:20 20f22dfc da_na325a1c33g3s0800hx.out 652,574 11-18-2019 21:42 66aad948 da_na325a1c33g3s0900hx.inp 4,143 11-18-2019 10:20 90ef22c3 da_na325a1c33g3s0900hx.out 652,498 11-18-2019 21:41 4c303154 da_na325a1c33g3s1000hx.inp 4,147 11-18-2019 10:20 1929038c da_na325a1c33g3s1000hx.out 652,997 11-18-2019 21:30 e8987f1d da_na325a1c33g3s1100hx.inp 4,147 11-18-2019 10:20 fbc84dbf da_na325a1c33g3s1100hx.out 653,056 11-18-2019 21:51 8e04b71d da_na325a1c33g3s1200hx.inp 4,147 11-18-2019 10:21 35522ab2 da_na325a1c33g3s1200hx.out 652,742 11-18-2019 21:41 d25e4071 da_na325a1c33g3s1300hx.inp 4,147 11-18-2019 10:21 f32a7d4f da_na325a1c33g3s1300hx.out 653,139 11-18-2019 21:37 f50534f1 da_na325a1c33g3s1400hx.inp 4,147 11-18-2019 10:21 3ff0536c da_na325a1c33g3s1400hx.out 652,816 11-18-2019 21:49 f2a48e89 da_na325a1c33g3s1500hx.inp 4,146 11-18-2019 10:21 d9f80a15 da_na325a1c33g3s1500hx.out 652,731 11-18-2019 21:52 2222c029
\\v1.2\\da\\ns245\\ (66) 20,111,673 11-20-2019 09:22 da_ns245a1c33g1s0500hx.inp 4,198 11-18-2019 17:03 b59e4987 da_ns245a1c33g1s0500hx.out 654,610 11-20-2019 04:28 e03390cf da_ns245a1c33g1s0600hx.inp 4,199 11-18-2019 17:03 e40ec543 da_ns245a1c33g1s0600hx.out 654,270 11-20-2019 04:20 7ca4a790 da_ns245a1c33g1s0700hx.inp 4,199 11-18-2019 17:03 05938760 da_ns245a1c33g1s0700hx.out 653,787 11-20-2019 04:27 63f26103 da_ns245a1c33g1s0800hx.inp 4,199 11-18-2019 17:03 ff1ce49d da_ns245a1c33g1s0800hx.out 653,906 11-20-2019 04:43 7d058478 da_ns245a1c33g1s0900hx.inp 4,199 11-18-2019 17:03 cfbfeb6d da_ns245a1c33g1s0900hx.out 653,163 11-20-2019 04:19 0c723e45 da_ns245a1c33g1s1000hx.inp 4,203 11-18-2019 17:03 b65db2af da_ns245a1c33g1s1000hx.out 654,320 11-20-2019 04:26 6cf7f26e da_ns245a1c33g1s1100hx.inp 4,203 11-18-2019 17:03 6fb9d890 da_ns245a1c33g1s1100hx.out 653,512 11-20-2019 04:31 5c26ab55 da_ns245a1c33g1s1200hx.inp 4,203 11-18-2019 17:04 2d23af96 da_ns245a1c33g1s1200hx.out 655,076 11-20-2019 04:31 a12cc4cc da_ns245a1c33g1s1300hx.inp 4,203 11-18-2019 17:04 3ea0a978 da_ns245a1c33g1s1300hx.out 653,964 11-20-2019 04:37 1e942730 da_ns245a1c33g1s1400hx.inp 4,203 11-18-2019 17:04 21fddfbf da_ns245a1c33g1s1400hx.out 654,010 11-20-2019 04:35 cceddfeb da_ns245a1c33g1s1500hx.inp 4,203 11-18-2019 17:04 e295b431 da_ns245a1c33g1s1500hx.out 654,018 11-20-2019 04:37 a7b62a65 da_ns245a1c33g2s0500hx.inp 4,196 11-18-2019 17:04 5d933b8e da_ns245a1c33g2s0500hx.out 507,255 11-20-2019 05:18 ec92638d da_ns245a1c33g2s0600hx.inp 4,197 11-18-2019 17:04 c152a9b1 da_ns245a1c33g2s0600hx.out 507,624 11-20-2019 05:13 a15864ba da_ns245a1c33g2s0700hx.inp 4,197 11-18-2019 17:04 54157b18 da_ns245a1c33g2s0700hx.out 507,829 11-20-2019 05:13 88da287b da_ns245a1c33g2s0800hx.inp 4,197 11-18-2019 17:04 10ff26a2 da_ns245a1c33g2s0800hx.out 508,320 11-20-2019 05:13 4d9007d3 da_ns245a1c33g2s0900hx.inp 4,197 11-18-2019 17:04 83944c69 da_ns245a1c33g2s0900hx.out 508,043 11-20-2019 05:11 3e6d6f20 da_ns245a1c33g2s1000hx.inp 4,201 11-18-2019 17:04 835bfe22 da_ns245a1c33g2s1000hx.out 508,113 11-20-2019 05:11 c19920da da_ns245a1c33g2s1100hx.inp 4,201 11-18-2019 17:04 5fad23ef da_ns245a1c33g2s1100hx.out 507,836 11-20-2019 05:17 f5a2fcb2 da_ns245a1c33g2s1200hx.inp 4,201 11-18-2019 17:05 a7666397 da_ns245a1c33g2s1200hx.out 508,015 11-20-2019 04:57 6190a44a da_ns245a1c33g2s1300hx.inp 4,201 11-18-2019 17:05 6158fb36 da_ns245a1c33g2s1300hx.out 507,458 11-20-2019 05:14 63850df6 da_ns245a1c33g2s1400hx.inp 4,201 11-18-2019 17:05 ea8afd65 da_ns245a1c33g2s1400hx.out 507,244 11-20-2019 05:11 ddadfb06 da_ns245a1c33g2s1500hx.inp 4,201 11-18-2019 17:05 a2a1a7d2 da_ns245a1c33g2s1500hx.out 507,550 11-20-2019 05:23 72d5ae25 da_ns245a1c33g3s0500hx.inp 4,193 11-18-2019 17:05 85707df3 da_ns245a1c33g3s0500hx.out 653,115 11-20-2019 05:03 0f118717 da_ns245a1c33g3s0600hx.inp 4,194 11-18-2019 17:05 ddd3ee62 da_ns245a1c33g3s0600hx.out 653,671 11-20-2019 05:02 dfcf7133 da_ns245a1c33g3s0700hx.inp 4,194 11-18-2019 17:05 eb54155a da_ns245a1c33g3s0700hx.out 653,730 11-20-2019 05:07 262e5014 da_ns245a1c33g3s0800hx.inp 4,194 11-18-2019 17:05 9e7ccd14 da_ns245a1c33g3s0800hx.out 654,226 11-20-2019 04:58 59662043 da_ns245a1c33g3s0900hx.inp 4,194 11-18-2019 17:05 07f848cc da_ns245a1c33g3s0900hx.out 653,584 11-20-2019 05:00 ebd51eb1 da_ns245a1c33g3s1000hx.inp 4,198 11-18-2019 17:05 5e501768 da_ns245a1c33g3s1000hx.out 653,195 11-20-2019 04:58 a35c7c6c da_ns245a1c33g3s1100hx.inp 4,198 11-18-2019 17:05 327d2c96 da_ns245a1c33g3s1100hx.out 654,240 11-20-2019 05:04 6f1e560c da_ns245a1c33g3s1200hx.inp 4,198 11-18-2019 17:06 b2dc805f
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
93 of 190 da_ns245a1c33g3s1200hx.out 654,421 11-20-2019 05:07 14c51329 da_ns245a1c33g3s1300hx.inp 4,198 11-18-2019 17:06 0c2b737b da_ns245a1c33g3s1300hx.out 654,756 11-20-2019 04:58 1d836a72 da_ns245a1c33g3s1400hx.inp 4,198 11-18-2019 17:06 35a47752 da_ns245a1c33g3s1400hx.out 654,292 11-20-2019 04:58 d7607e45 da_ns245a1c33g3s1500hx.inp 4,198 11-18-2019 17:06 891a1f2f da_ns245a1c33g3s1500hx.out 653,961 11-20-2019 04:58 ca6f7981
\\v1.2\\da\\ns325\\ (66) 20,076,209 11-20-2019 09:22 da_ns325a1c33g1s0500hx.inp 4,149 11-18-2019 15:58 00cbae4b da_ns325a1c33g1s0500hx.out 653,931 11-19-2019 23:09 6ead16ad da_ns325a1c33g1s0600hx.inp 4,149 11-18-2019 15:59 63749915 da_ns325a1c33g1s0600hx.out 652,884 11-19-2019 23:08 8dc03393 da_ns325a1c33g1s0700hx.inp 4,149 11-18-2019 15:59 673e9a3f da_ns325a1c33g1s0700hx.out 652,578 11-19-2019 23:19 03e0285f da_ns325a1c33g1s0800hx.inp 4,149 11-18-2019 15:59 24b8b13b da_ns325a1c33g1s0800hx.out 652,384 11-19-2019 23:09 1c9f2638 da_ns325a1c33g1s0900hx.inp 4,149 11-18-2019 15:59 2947cd6c da_ns325a1c33g1s0900hx.out 652,491 11-19-2019 23:24 df03c2f4 da_ns325a1c33g1s1000hx.inp 4,153 11-18-2019 15:59 0052d837 da_ns325a1c33g1s1000hx.out 653,203 11-19-2019 23:16 9a2e820c da_ns325a1c33g1s1100hx.inp 4,153 11-18-2019 15:59 eea31711 da_ns325a1c33g1s1100hx.out 652,351 11-19-2019 23:19 d47a488e da_ns325a1c33g1s1200hx.inp 4,153 11-18-2019 15:59 d3063712 da_ns325a1c33g1s1200hx.out 653,657 11-19-2019 23:12 08f84d8b da_ns325a1c33g1s1300hx.inp 4,153 11-18-2019 15:59 1b3132b5 da_ns325a1c33g1s1300hx.out 652,573 11-19-2019 23:20 076d8479 da_ns325a1c33g1s1400hx.inp 4,153 11-18-2019 15:59 e3b979e2 da_ns325a1c33g1s1400hx.out 652,836 11-19-2019 23:22 c63c020d da_ns325a1c33g1s1500hx.inp 4,152 11-18-2019 15:59 343c623f da_ns325a1c33g1s1500hx.out 653,965 11-19-2019 23:25 9687fdf0 da_ns325a1c33g2s0500hx.inp 4,147 11-18-2019 15:59 5ca20b82 da_ns325a1c33g2s0500hx.out 506,588 11-19-2019 23:54 3cd66162 da_ns325a1c33g2s0600hx.inp 4,147 11-18-2019 15:59 00851101 da_ns325a1c33g2s0600hx.out 506,436 11-20-2019 00:00 8ec93590 da_ns325a1c33g2s0700hx.inp 4,147 11-18-2019 16:00 ce722566 da_ns325a1c33g2s0700hx.out 505,874 11-19-2019 23:59 790e9942 da_ns325a1c33g2s0800hx.inp 4,147 11-18-2019 16:00 3c511ab4 da_ns325a1c33g2s0800hx.out 506,471 11-20-2019 00:03 2079d127 da_ns325a1c33g2s0900hx.inp 4,147 11-18-2019 16:00 a416a635 da_ns325a1c33g2s0900hx.out 506,062 11-19-2019 23:55 414441eb da_ns325a1c33g2s1000hx.inp 4,151 11-18-2019 16:00 c8eeb6d1 da_ns325a1c33g2s1000hx.out 506,301 11-19-2019 23:48 96f1af15 da_ns325a1c33g2s1100hx.inp 4,151 11-18-2019 16:00 351beafb da_ns325a1c33g2s1100hx.out 507,050 11-19-2019 23:50 894aec95 da_ns325a1c33g2s1200hx.inp 4,151 11-18-2019 16:00 1e398745 da_ns325a1c33g2s1200hx.out 506,984 11-19-2019 23:54 283c818b da_ns325a1c33g2s1300hx.inp 4,151 11-18-2019 16:00 e6f87c8a da_ns325a1c33g2s1300hx.out 506,804 11-19-2019 23:59 a06dbfe4 da_ns325a1c33g2s1400hx.inp 4,151 11-18-2019 16:00 30e201ac da_ns325a1c33g2s1400hx.out 506,897 11-19-2019 23:49 cab13571 da_ns325a1c33g2s1500hx.inp 4,151 11-18-2019 16:00 60455df6 da_ns325a1c33g2s1500hx.out 506,846 11-19-2019 23:48 97c750fd da_ns325a1c33g3s0500hx.inp 4,144 11-18-2019 16:00 a2bd2cb7 da_ns325a1c33g3s0500hx.out 652,167 11-19-2019 23:48 d938a835 da_ns325a1c33g3s0600hx.inp 4,144 11-18-2019 16:00 3912ec12 da_ns325a1c33g3s0600hx.out 652,985 11-19-2019 23:45 feb2d24f da_ns325a1c33g3s0700hx.inp 4,144 11-18-2019 16:01 bc68c39e da_ns325a1c33g3s0700hx.out 651,958 11-19-2019 23:42 87478ecd da_ns325a1c33g3s0800hx.inp 4,144 11-18-2019 16:01 b66753c8 da_ns325a1c33g3s0800hx.out 652,995 11-19-2019 23:40 05accbf7 da_ns325a1c33g3s0900hx.inp 4,144 11-18-2019 16:01 5f903512 da_ns325a1c33g3s0900hx.out 653,708 11-19-2019 23:48 cbfbcba1 da_ns325a1c33g3s1000hx.inp 4,148 11-18-2019 16:01 8f9dabfb da_ns325a1c33g3s1000hx.out 652,930 11-19-2019 23:37 d97c5168 da_ns325a1c33g3s1100hx.inp 4,148 11-18-2019 16:01 613e2f16 da_ns325a1c33g3s1100hx.out 653,039 11-19-2019 23:40 44050c94 da_ns325a1c33g3s1200hx.inp 4,148 11-18-2019 16:01 803607e6 da_ns325a1c33g3s1200hx.out 653,692 11-19-2019 23:42 e122ba9c da_ns325a1c33g3s1300hx.inp 4,148 11-18-2019 16:01 46a1bc31 da_ns325a1c33g3s1300hx.out 653,021 11-19-2019 23:44 8b0a1808 da_ns325a1c33g3s1400hx.inp 4,148 11-18-2019 16:01 789c32e6 da_ns325a1c33g3s1400hx.out 653,803 11-19-2019 23:47 e5ed84f6 da_ns325a1c33g3s1500hx.inp 4,147 11-18-2019 16:01 3536e71d da_ns325a1c33g3s1500hx.out 653,835 11-19-2019 23:54 0394cb81
\\v1.2\\db\\ (0) 57,927,691 11-18-2019 17:06
\\v1.2\\db\\ha245\\ (22) 7,246,229 11-18-2019 20:33
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
94 of 190 db_ha245c1c33g0s0500hx.inp 4,268 11-18-2019 02:09 ee182497 db_ha245c1c33g0s0500hx.out 655,538 11-18-2019 13:06 fcd70495 db_ha245c1c33g0s0600hx.inp 4,269 11-18-2019 02:09 cf4d67cc db_ha245c1c33g0s0600hx.out 654,081 11-18-2019 13:03 af79b088 db_ha245c1c33g0s0700hx.inp 4,269 11-18-2019 02:09 3edd8c75 db_ha245c1c33g0s0700hx.out 654,379 11-18-2019 13:02 d47d6836 db_ha245c1c33g0s0800hx.inp 4,269 11-18-2019 02:10 4d05c159 db_ha245c1c33g0s0800hx.out 654,684 11-18-2019 13:01 49e48c5c db_ha245c1c33g0s0900hx.inp 4,269 11-18-2019 02:10 93382c1e db_ha245c1c33g0s0900hx.out 653,929 11-18-2019 13:00 ff963f22 db_ha245c1c33g0s1000hx.inp 4,273 11-18-2019 02:10 6ad416bb db_ha245c1c33g0s1000hx.out 654,189 11-18-2019 13:04 d79386ab db_ha245c1c33g0s1100hx.inp 4,273 11-18-2019 02:10 3a866261 db_ha245c1c33g0s1100hx.out 654,547 11-18-2019 13:04 4ebb2e94 db_ha245c1c33g0s1200hx.inp 4,273 11-18-2019 02:10 b93101d9 db_ha245c1c33g0s1200hx.out 654,147 11-18-2019 13:02 b1e9a6e2 db_ha245c1c33g0s1300hx.inp 4,273 11-18-2019 02:10 40731157 db_ha245c1c33g0s1300hx.out 654,593 11-18-2019 13:05 d9b64355 db_ha245c1c33g0s1400hx.inp 4,273 11-18-2019 02:10 75caeb57 db_ha245c1c33g0s1400hx.out 654,476 11-18-2019 13:05 acab5d77 db_ha245c1c33g0s1500hx.inp 4,273 11-18-2019 02:10 4d604522 db_ha245c1c33g0s1500hx.out 654,684 11-18-2019 13:07 d3bf00d5
\\v1.2\\db\\ha325\\ (22) 7,235,984 11-18-2019 20:33 db_ha325c1c33g0s0500hx.inp 4,214 11-18-2019 00:16 df8f2147 db_ha325c1c33g0s0500hx.out 653,791 11-18-2019 03:26 7bb29d49 db_ha325c1c33g0s0600hx.inp 4,214 11-18-2019 00:16 a36918a7 db_ha325c1c33g0s0600hx.out 653,307 11-18-2019 03:23 84ed9d87 db_ha325c1c33g0s0700hx.inp 4,214 11-18-2019 00:16 4b1b6adc db_ha325c1c33g0s0700hx.out 653,323 11-18-2019 03:22 a1179e2d db_ha325c1c33g0s0800hx.inp 4,214 11-18-2019 00:16 88408a5d db_ha325c1c33g0s0800hx.out 653,943 11-18-2019 03:22 e98166b3 db_ha325c1c33g0s0900hx.inp 4,214 11-18-2019 00:16 7f769e0a db_ha325c1c33g0s0900hx.out 654,152 11-18-2019 03:22 3175ba3a db_ha325c1c33g0s1000hx.inp 4,218 11-18-2019 00:16 4e97067b db_ha325c1c33g0s1000hx.out 653,877 11-18-2019 03:22 ab411e1d db_ha325c1c33g0s1100hx.inp 4,218 11-18-2019 00:16 9ac77a41 db_ha325c1c33g0s1100hx.out 653,625 11-18-2019 03:23 d3bca5cf db_ha325c1c33g0s1200hx.inp 4,218 11-18-2019 00:16 e14d35ea db_ha325c1c33g0s1200hx.out 653,525 11-18-2019 03:25 866c2f59 db_ha325c1c33g0s1300hx.inp 4,218 11-18-2019 00:16 9bd9c74b db_ha325c1c33g0s1300hx.out 653,587 11-18-2019 03:26 964cd662 db_ha325c1c33g0s1400hx.inp 4,218 11-18-2019 00:16 7c49b3ad db_ha325c1c33g0s1400hx.out 652,936 11-18-2019 03:27 adfa6f7f db_ha325c1c33g0s1500hx.inp 4,217 11-18-2019 00:17 bfe3143f db_ha325c1c33g0s1500hx.out 653,541 11-18-2019 03:22 c0e84bd3
\\v1.2\\db\\hs245\\ (22) 7,246,115 11-20-2019 09:22 db_hs245c1c33g0s0500hx.inp 4,296 11-18-2019 14:34 3458e5a1 db_hs245c1c33g0s0500hx.out 653,967 11-19-2019 18:12 fe746a7c db_hs245c1c33g0s0600hx.inp 4,297 11-18-2019 14:34 c11d0c5b db_hs245c1c33g0s0600hx.out 655,132 11-19-2019 18:13 a2f22056 db_hs245c1c33g0s0700hx.inp 4,297 11-18-2019 14:34 57ad96d1 db_hs245c1c33g0s0700hx.out 655,330 11-19-2019 18:12 78fc7677 db_hs245c1c33g0s0800hx.inp 4,297 11-18-2019 14:34 0ccdcb51 db_hs245c1c33g0s0800hx.out 654,784 11-19-2019 18:16 7756014d db_hs245c1c33g0s0900hx.inp 4,297 11-18-2019 14:34 1d355576 db_hs245c1c33g0s0900hx.out 654,154 11-19-2019 18:09 a97c678a db_hs245c1c33g0s1000hx.inp 4,301 11-18-2019 14:34 984afa7b db_hs245c1c33g0s1000hx.out 654,139 11-19-2019 18:12 ff726bce db_hs245c1c33g0s1100hx.inp 4,301 11-18-2019 14:35 e81074e0 db_hs245c1c33g0s1100hx.out 653,702 11-19-2019 18:13 502c6f56 db_hs245c1c33g0s1200hx.inp 4,301 11-18-2019 14:35 2ab211da db_hs245c1c33g0s1200hx.out 653,949 11-19-2019 18:21 c34952dd db_hs245c1c33g0s1300hx.inp 4,301 11-18-2019 14:35 f26bda20 db_hs245c1c33g0s1300hx.out 654,849 11-19-2019 18:24 1e15e0ca db_hs245c1c33g0s1400hx.inp 4,301 11-18-2019 14:35 6badec3e db_hs245c1c33g0s1400hx.out 654,742 11-19-2019 18:19 f2b9d808 db_hs245c1c33g0s1500hx.inp 4,301 11-18-2019 14:35 111ad5f6 db_hs245c1c33g0s1500hx.out 654,077 11-19-2019 18:11 141aa739
\\v1.2\\db\\hs325\\ (22) 7,233,531 11-20-2019 09:22 db_hs325c1c33g0s0500hx.inp 4,247 11-18-2019 12:46 7e45382d db_hs325c1c33g0s0500hx.out 652,971 11-19-2019 12:59 21ec65cf db_hs325c1c33g0s0600hx.inp 4,247 11-18-2019 12:47 cc6a5490 db_hs325c1c33g0s0600hx.out 653,953 11-19-2019 12:59 07f1d983 db_hs325c1c33g0s0700hx.inp 4,247 11-18-2019 12:47 15e3094e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
95 of 190 db_hs325c1c33g0s0700hx.out 653,047 11-19-2019 12:59 d47031f1 db_hs325c1c33g0s0800hx.inp 4,247 11-18-2019 12:47 775b3661 db_hs325c1c33g0s0800hx.out 652,715 11-19-2019 13:01 fdfa5dc4 db_hs325c1c33g0s0900hx.inp 4,247 11-18-2019 12:47 a3dcd6dc db_hs325c1c33g0s0900hx.out 653,476 11-19-2019 13:01 e1a49087 db_hs325c1c33g0s1000hx.inp 4,251 11-18-2019 12:47 5cfe9f4c db_hs325c1c33g0s1000hx.out 654,034 11-19-2019 13:00 3ec338e1 db_hs325c1c33g0s1100hx.inp 4,251 11-18-2019 12:47 cbec7f33 db_hs325c1c33g0s1100hx.out 653,522 11-19-2019 13:04 6f62eed4 db_hs325c1c33g0s1200hx.inp 4,251 11-18-2019 12:47 5e659505 db_hs325c1c33g0s1200hx.out 653,175 11-19-2019 13:06 c6cdda5c db_hs325c1c33g0s1300hx.inp 4,251 11-18-2019 12:47 4c8f7a6a db_hs325c1c33g0s1300hx.out 653,593 11-19-2019 13:08 1942ccce db_hs325c1c33g0s1400hx.inp 4,251 11-18-2019 12:47 b6b77f44 db_hs325c1c33g0s1400hx.out 652,882 11-19-2019 13:20 d77cfeb8 db_hs325c1c33g0s1500hx.inp 4,250 11-18-2019 12:47 a8ddcce1 db_hs325c1c33g0s1500hx.out 653,423 11-19-2019 13:11 80fa4dd3
\\v1.2\\db\\na245\\ (22) 7,245,209 11-20-2019 09:22 db_na245c1c33g0s0500hx.inp 4,295 11-18-2019 11:24 81b497f1 db_na245c1c33g0s0500hx.out 655,016 11-19-2019 05:24 83135c54 db_na245c1c33g0s0600hx.inp 4,296 11-18-2019 11:24 df9151ec db_na245c1c33g0s0600hx.out 653,594 11-19-2019 05:19 281dbe39 db_na245c1c33g0s0700hx.inp 4,296 11-18-2019 11:24 8205793c db_na245c1c33g0s0700hx.out 654,533 11-19-2019 05:19 c9365817 db_na245c1c33g0s0800hx.inp 4,296 11-18-2019 11:24 5086d37e db_na245c1c33g0s0800hx.out 654,365 11-19-2019 05:39 34005541 db_na245c1c33g0s0900hx.inp 4,296 11-18-2019 11:24 2ec1d65a db_na245c1c33g0s0900hx.out 654,337 11-19-2019 05:11 0d8ff6f7 db_na245c1c33g0s1000hx.inp 4,300 11-18-2019 11:24 4fe86e17 db_na245c1c33g0s1000hx.out 654,246 11-19-2019 05:28 566de46c db_na245c1c33g0s1100hx.inp 4,300 11-18-2019 11:24 f8cc0688 db_na245c1c33g0s1100hx.out 654,443 11-19-2019 05:29 73c5021c db_na245c1c33g0s1200hx.inp 4,300 11-18-2019 11:24 2cf766c3 db_na245c1c33g0s1200hx.out 653,604 11-19-2019 05:30 bbdf9e73 db_na245c1c33g0s1300hx.inp 4,300 11-18-2019 11:24 404cad18 db_na245c1c33g0s1300hx.out 654,430 11-19-2019 05:21 2ea0042e db_na245c1c33g0s1400hx.inp 4,300 11-18-2019 11:24 258a6161 db_na245c1c33g0s1400hx.out 654,828 11-19-2019 05:31 ae192b03 db_na245c1c33g0s1500hx.inp 4,300 11-18-2019 11:24 b3acfe17 db_na245c1c33g0s1500hx.out 654,534 11-19-2019 05:36 65e2ce04
\\v1.2\\db\\na325\\ (22) 7,233,534 11-20-2019 09:22 db_na325c1c33g0s0500hx.inp 4,246 11-18-2019 10:21 d399e7ed db_na325c1c33g0s0500hx.out 652,549 11-18-2019 21:48 aa070c1b db_na325c1c33g0s0600hx.inp 4,246 11-18-2019 10:21 e36c6cea db_na325c1c33g0s0600hx.out 653,640 11-18-2019 21:25 7360e071 db_na325c1c33g0s0700hx.inp 4,246 11-18-2019 10:21 0ccdb4fa db_na325c1c33g0s0700hx.out 653,298 11-18-2019 21:36 1a4efd81 db_na325c1c33g0s0800hx.inp 4,246 11-18-2019 10:21 21f56b03 db_na325c1c33g0s0800hx.out 653,909 11-18-2019 21:36 d4ff0458 db_na325c1c33g0s0900hx.inp 4,246 11-18-2019 10:21 c9b29195 db_na325c1c33g0s0900hx.out 652,558 11-18-2019 22:00 70736335 db_na325c1c33g0s1000hx.inp 4,250 11-18-2019 10:21 6fa94b2e db_na325c1c33g0s1000hx.out 653,735 11-18-2019 21:36 146f2c6f db_na325c1c33g0s1100hx.inp 4,250 11-18-2019 10:21 47fb2472 db_na325c1c33g0s1100hx.out 653,399 11-18-2019 21:59 0d7cbd0d db_na325c1c33g0s1200hx.inp 4,250 11-18-2019 10:21 82ca5601 db_na325c1c33g0s1200hx.out 653,295 11-18-2019 21:40 854df935 db_na325c1c33g0s1300hx.inp 4,250 11-18-2019 10:22 940ee9ce db_na325c1c33g0s1300hx.out 653,229 11-18-2019 21:37 54718a7b db_na325c1c33g0s1400hx.inp 4,250 11-18-2019 10:22 832b646f db_na325c1c33g0s1400hx.out 653,437 11-18-2019 22:12 9465b2d4 db_na325c1c33g0s1500hx.inp 4,249 11-18-2019 10:22 27887374 db_na325c1c33g0s1500hx.out 653,756 11-18-2019 21:50 74bff10f
\\v1.2\\db\\ns245\\ (22) 7,248,551 11-20-2019 09:22 db_ns245c1c33g0s0500hx.inp 4,296 11-18-2019 17:06 ef447859 db_ns245c1c33g0s0500hx.out 655,070 11-20-2019 04:50 291294c4 db_ns245c1c33g0s0600hx.inp 4,297 11-18-2019 17:06 40496747 db_ns245c1c33g0s0600hx.out 654,784 11-20-2019 04:55 dc50df51 db_ns245c1c33g0s0700hx.inp 4,297 11-18-2019 17:06 d6f9fdcd db_ns245c1c33g0s0700hx.out 654,149 11-20-2019 04:51 8e75fa57 db_ns245c1c33g0s0800hx.inp 4,297 11-18-2019 17:06 8d99a04d db_ns245c1c33g0s0800hx.out 654,924 11-20-2019 04:50 1dc062f8 db_ns245c1c33g0s0900hx.inp 4,297 11-18-2019 17:06 9c613e6a db_ns245c1c33g0s0900hx.out 654,852 11-20-2019 04:57 2d491f3a db_ns245c1c33g0s1000hx.inp 4,301 11-18-2019 17:06 ea54cf97
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
96 of 190 db_ns245c1c33g0s1000hx.out 654,145 11-20-2019 04:52 b61cade5 db_ns245c1c33g0s1100hx.inp 4,301 11-18-2019 17:06 9a0e410c db_ns245c1c33g0s1100hx.out 655,114 11-20-2019 04:54 e529f551 db_ns245c1c33g0s1200hx.inp 4,301 11-18-2019 17:07 58ac2436 db_ns245c1c33g0s1200hx.out 654,599 11-20-2019 04:53 f877c4d7 db_ns245c1c33g0s1300hx.inp 4,301 11-18-2019 17:07 8075efcc db_ns245c1c33g0s1300hx.out 654,648 11-20-2019 04:54 5d7940a0 db_ns245c1c33g0s1400hx.inp 4,301 11-18-2019 17:07 19b3d9d2 db_ns245c1c33g0s1400hx.out 654,654 11-20-2019 04:58 e19afacb db_ns245c1c33g0s1500hx.inp 4,301 11-18-2019 17:07 6304e01a db_ns245c1c33g0s1500hx.out 654,322 11-20-2019 05:07 bfd3817f
\\v1.2\\db\\ns325\\ (22) 7,238,538 11-20-2019 09:22 db_ns325c1c33g0s0500hx.inp 4,247 11-18-2019 16:01 a0f5c9c1 db_ns325c1c33g0s0500hx.out 653,632 11-19-2019 23:34 6a73420a db_ns325c1c33g0s0600hx.inp 4,247 11-18-2019 16:01 12daa57c db_ns325c1c33g0s0600hx.out 653,666 11-19-2019 23:47 54bf67f3 db_ns325c1c33g0s0700hx.inp 4,247 11-18-2019 16:02 cb53f8a2 db_ns325c1c33g0s0700hx.out 653,199 11-19-2019 23:31 f7e5fddf db_ns325c1c33g0s0800hx.inp 4,247 11-18-2019 16:02 a9ebc78d db_ns325c1c33g0s0800hx.out 654,208 11-19-2019 23:47 cbaf3573 db_ns325c1c33g0s0900hx.inp 4,247 11-18-2019 16:02 7d6c2730 db_ns325c1c33g0s0900hx.out 654,077 11-19-2019 23:32 ec1c5881 db_ns325c1c33g0s1000hx.inp 4,251 11-18-2019 16:02 37f6d8e1 db_ns325c1c33g0s1000hx.out 654,491 11-19-2019 23:44 13c774d7 db_ns325c1c33g0s1100hx.inp 4,251 11-18-2019 16:02 a0e4389e db_ns325c1c33g0s1100hx.out 654,170 11-19-2019 23:37 60a7e305 db_ns325c1c33g0s1200hx.inp 4,251 11-18-2019 16:02 356dd2a8 db_ns325c1c33g0s1200hx.out 653,608 11-19-2019 23:40 0491246e db_ns325c1c33g0s1300hx.inp 4,251 11-18-2019 16:02 27873dc7 db_ns325c1c33g0s1300hx.out 653,324 11-19-2019 23:38 3131b35c db_ns325c1c33g0s1400hx.inp 4,251 11-18-2019 16:02 ddbf38e9 db_ns325c1c33g0s1400hx.out 653,506 11-19-2019 23:43 9bda9461 db_ns325c1c33g0s1500hx.inp 4,250 11-18-2019 16:02 faaad99d db_ns325c1c33g0s1500hx.out 653,917 11-19-2019 23:45 5d3fa8f1
\\v1.2\\dd\\ (0) 47,393,218 11-18-2019 17:07
\\v1.2\\dd\\ha245\\ (18) 5,927,883 11-22-2019 12:48 dd_ha245c1c33g0s001vfio.inp 4,269 11-18-2019 02:10 872de829 dd_ha245c1c33g0s001vfio.out 654,655 11-18-2019 11:55 e43f75ce dd_ha245c1c33g0s005vfio.inp 4,269 11-18-2019 02:10 1f058d2f dd_ha245c1c33g0s005vfio.out 654,600 11-18-2019 11:44 5eee017b dd_ha245c1c33g0s010vfio.inp 4,269 11-18-2019 02:10 cce2d854 dd_ha245c1c33g0s010vfio.out 654,408 11-18-2019 11:49 e8329df3 dd_ha245c1c33g0s030vfio.inp 4,269 11-18-2019 02:10 424f676f dd_ha245c1c33g0s030vfio.out 654,488 11-18-2019 12:16 507848e3 dd_ha245c1c33g0s050vfio.inp 4,269 11-18-2019 02:11 eded5a19 dd_ha245c1c33g0s050vfio.out 653,691 11-18-2019 12:40 a4a7ad16 dd_ha245c1c33g0s070vfio.inp 4,269 11-18-2019 02:11 83558c88 dd_ha245c1c33g0s070vfio.out 654,399 11-18-2019 12:51 3994174c dd_ha245c1c33g0s090vfio.inp 4,269 11-18-2019 02:11 3673ab1e dd_ha245c1c33g0s090vfio.out 654,629 11-18-2019 12:58 7876d55a dd_ha245c1c33g0s095vfio.inp 4,269 11-18-2019 02:11 4961f030 dd_ha245c1c33g0s095vfio.out 654,661 11-18-2019 12:59 dbdb0862 dd_ha245c1c33g0s100vfio.inp 4,269 11-18-2019 02:11 93382c1e dd_ha245c1c33g0s100vfio.out 653,931 11-18-2019 13:00 219298a0
\\v1.2\\dd\\ha325\\ (18) 5,919,241 11-22-2019 12:48 dd_ha325c1c33g0s001vfio.inp 4,214 11-18-2019 00:17 6bae796d dd_ha325c1c33g0s001vfio.out 653,160 11-18-2019 02:15 375e98c5 dd_ha325c1c33g0s005vfio.inp 4,214 11-18-2019 00:17 b4903e5f dd_ha325c1c33g0s005vfio.out 653,278 11-18-2019 02:02 4b083dff dd_ha325c1c33g0s010vfio.inp 4,214 11-18-2019 00:17 340bad7a dd_ha325c1c33g0s010vfio.out 653,550 11-18-2019 02:09 f1ac1981 dd_ha325c1c33g0s030vfio.inp 4,214 11-18-2019 00:17 f2fc033d dd_ha325c1c33g0s030vfio.out 653,865 11-18-2019 02:37 7cdc40ad dd_ha325c1c33g0s050vfio.inp 4,214 11-18-2019 00:17 0bf775c5 dd_ha325c1c33g0s050vfio.out 653,952 11-18-2019 02:59 f67f5f91 dd_ha325c1c33g0s070vfio.inp 4,214 11-18-2019 00:17 6038c8cc dd_ha325c1c33g0s070vfio.out 653,430 11-18-2019 03:13 2a116bd6 dd_ha325c1c33g0s090vfio.inp 4,214 11-18-2019 00:17 16a41879 dd_ha325c1c33g0s090vfio.out 653,821 11-18-2019 03:20 714de684 dd_ha325c1c33g0s095vfio.inp 4,214 11-18-2019 00:17 bb334408 dd_ha325c1c33g0s095vfio.out 652,105 11-18-2019 03:21 b1531e6a dd_ha325c1c33g0s100vfio.inp 4,214 11-18-2019 00:17 7f769e0a dd_ha325c1c33g0s100vfio.out 654,154 11-18-2019 03:25 01c1c5a0
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
97 of 190
\\v1.2\\dd\\hs245\\ (18) 5,928,351 11-22-2019 12:48 dd_hs245c1c33g0s001vfi.inp 4,297 11-18-2019 14:35 db038dbc dd_hs245c1c33g0s001vfi.out 654,472 11-19-2019 17:55 dfaacbd1 dd_hs245c1c33g0s005vfi.inp 4,297 11-18-2019 14:35 58f61aab dd_hs245c1c33g0s005vfi.out 654,541 11-19-2019 17:54 b81226c0 dd_hs245c1c33g0s010vfi.inp 4,297 11-18-2019 14:35 7fbc2b3f dd_hs245c1c33g0s010vfi.out 655,797 11-19-2019 17:37 f543a479 dd_hs245c1c33g0s030vfi.inp 4,297 11-18-2019 14:35 3b739c9d dd_hs245c1c33g0s030vfi.out 653,577 11-19-2019 17:34 38596abc dd_hs245c1c33g0s050vfi.inp 4,297 11-18-2019 14:35 0d48c1a2 dd_hs245c1c33g0s050vfi.out 654,572 11-19-2019 17:46 35bd8fa7 dd_hs245c1c33g0s070vfi.inp 4,297 11-18-2019 14:36 523f657a dd_hs245c1c33g0s070vfi.out 654,163 11-19-2019 18:05 9ba6c2fd dd_hs245c1c33g0s090vfi.inp 4,297 11-18-2019 14:36 fd419da9 dd_hs245c1c33g0s090vfi.out 654,103 11-19-2019 18:13 fb3e5938 dd_hs245c1c33g0s095vfi.inp 4,297 11-18-2019 14:36 7a8397c5 dd_hs245c1c33g0s095vfi.out 654,297 11-19-2019 18:05 e42a1b99 dd_hs245c1c33g0s100vfi.inp 4,297 11-18-2019 14:36 1d355576 dd_hs245c1c33g0s100vfi.out 654,156 11-19-2019 18:18 3046cf9d
\\v1.2\\dd\\hs325\\ (18) 5,918,764 11-22-2019 12:48 dd_hs325c1c33g0s001vfi.inp 4,247 11-18-2019 12:47 880bb179 dd_hs325c1c33g0s001vfi.out 653,905 11-19-2019 12:52 abefe5a8 dd_hs325c1c33g0s005vfi.inp 4,247 11-18-2019 12:47 8a1ce21f dd_hs325c1c33g0s005vfi.out 654,094 11-19-2019 12:28 8e36976a dd_hs325c1c33g0s010vfi.inp 4,247 11-18-2019 12:48 8c592277 dd_hs325c1c33g0s010vfi.out 653,985 11-19-2019 12:23 435714de dd_hs325c1c33g0s030vfi.inp 4,247 11-18-2019 12:48 9cc9ddb1 dd_hs325c1c33g0s030vfi.out 652,200 11-19-2019 12:28 01c7d6eb dd_hs325c1c33g0s050vfi.inp 4,247 11-18-2019 12:48 60e5f934 dd_hs325c1c33g0s050vfi.out 653,975 11-19-2019 12:49 a0e6d5b3 dd_hs325c1c33g0s070vfi.inp 4,247 11-18-2019 12:48 5f6c5e16 dd_hs325c1c33g0s070vfi.out 653,175 11-19-2019 12:53 73f663de dd_hs325c1c33g0s090vfi.inp 4,247 11-18-2019 12:48 8dd74599 dd_hs325c1c33g0s090vfi.out 652,619 11-19-2019 13:02 a816c4b0 dd_hs325c1c33g0s095vfi.inp 4,247 11-18-2019 12:48 7ad60e8b dd_hs325c1c33g0s095vfi.out 653,112 11-19-2019 13:06 ef3806fe dd_hs325c1c33g0s100vfi.inp 4,247 11-18-2019 12:48 a3dcd6dc dd_hs325c1c33g0s100vfi.out 653,476 11-19-2019 13:07 a7b5b84f
\\v1.2\\dd\\na245\\ (18) 5,931,217 11-22-2019 12:48 dd_na245c1c33g0s001vfio.inp 4,296 11-18-2019 11:25 ad6acb55 dd_na245c1c33g0s001vfio.out 654,899 11-19-2019 04:09 7f0f3a7f dd_na245c1c33g0s005vfio.inp 4,296 11-18-2019 11:25 801c73de dd_na245c1c33g0s005vfio.out 654,379 11-19-2019 04:07 4b26b066 dd_na245c1c33g0s010vfio.inp 4,296 11-18-2019 11:25 c75a6691 dd_na245c1c33g0s010vfio.out 654,539 11-19-2019 04:24 54a96272 dd_na245c1c33g0s030vfio.inp 4,296 11-18-2019 11:25 d6b01ef3 dd_na245c1c33g0s030vfio.out 654,565 11-19-2019 04:57 a198f3ea dd_na245c1c33g0s050vfio.inp 4,296 11-18-2019 11:25 ba5c7955 dd_na245c1c33g0s050vfio.out 654,914 11-19-2019 05:30 7aa2c682 dd_na245c1c33g0s070vfio.inp 4,296 11-18-2019 11:25 0c7becc7 dd_na245c1c33g0s070vfio.out 655,376 11-19-2019 05:27 178fabb9 dd_na245c1c33g0s090vfio.inp 4,296 11-18-2019 11:25 bb493bde dd_na245c1c33g0s090vfio.out 654,749 11-19-2019 05:43 88252792 dd_na245c1c33g0s095vfio.inp 4,296 11-18-2019 11:25 5b6317aa dd_na245c1c33g0s095vfio.out 654,788 11-19-2019 05:36 927da68a dd_na245c1c33g0s100vfio.inp 4,296 11-18-2019 11:25 2ec1d65a dd_na245c1c33g0s100vfio.out 654,344 11-19-2019 05:35 83ed7312
\\v1.2\\dd\\na325\\ (18) 5,919,166 11-22-2019 12:48 dd_na325c1c33g0s001vfio.inp 4,246 11-18-2019 10:22 49788684 dd_na325c1c33g0s001vfio.out 653,967 11-18-2019 20:23 a460579c dd_na325c1c33g0s005vfio.inp 4,246 11-18-2019 10:22 238a711d dd_na325c1c33g0s005vfio.out 654,352 11-18-2019 20:12 89a4fb63 dd_na325c1c33g0s010vfio.inp 4,246 11-18-2019 10:22 18aaf0c9 dd_na325c1c33g0s010vfio.out 653,795 11-18-2019 20:34 2f5c6ffc dd_na325c1c33g0s030vfio.inp 4,246 11-18-2019 10:22 00eaca2c dd_na325c1c33g0s030vfio.out 653,059 11-18-2019 21:23 71b59d36 dd_na325c1c33g0s050vfio.inp 4,246 11-18-2019 10:22 76184758 dd_na325c1c33g0s050vfio.out 653,331 11-18-2019 21:27 5d3e0f22 dd_na325c1c33g0s070vfio.inp 4,246 11-18-2019 10:22 e941a908 dd_na325c1c33g0s070vfio.out 653,463 11-18-2019 21:38 3ace3806 dd_na325c1c33g0s090vfio.inp 4,246 11-18-2019 10:22 2f632946 dd_na325c1c33g0s090vfio.out 653,007 11-18-2019 21:40 76dd31aa dd_na325c1c33g0s095vfio.inp 4,246 11-18-2019 10:22 591fe5ba
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
98 of 190 dd_na325c1c33g0s095vfio.out 653,415 11-18-2019 21:42 194c60df dd_na325c1c33g0s100vfio.inp 4,246 11-18-2019 10:23 c9b29195 dd_na325c1c33g0s100vfio.out 652,563 11-18-2019 21:46 b162543c
\\v1.2\\dd\\ns245\\ (18) 5,929,054 11-22-2019 12:48 dd_ns245c1c33g0s001vfi.inp 4,297 11-18-2019 17:07 5a57e6a0 dd_ns245c1c33g0s001vfi.out 654,823 11-20-2019 04:36 d536b68f dd_ns245c1c33g0s005vfi.inp 4,297 11-18-2019 17:07 d9a271b7 dd_ns245c1c33g0s005vfi.out 654,134 11-20-2019 04:19 c137b1f2 dd_ns245c1c33g0s010vfi.inp 4,297 11-18-2019 17:07 fee84023 dd_ns245c1c33g0s010vfi.out 653,898 11-20-2019 04:13 70d33317 dd_ns245c1c33g0s030vfi.inp 4,297 11-18-2019 17:07 ba27f781 dd_ns245c1c33g0s030vfi.out 654,766 11-20-2019 04:29 6d8f3b1a dd_ns245c1c33g0s050vfi.inp 4,297 11-18-2019 17:07 8c1caabe dd_ns245c1c33g0s050vfi.out 654,341 11-20-2019 05:06 c644e66e dd_ns245c1c33g0s070vfi.inp 4,297 11-18-2019 17:07 d36b0e66 dd_ns245c1c33g0s070vfi.out 654,788 11-20-2019 04:52 e6ec1e5d dd_ns245c1c33g0s090vfi.inp 4,297 11-18-2019 17:07 7c15f6b5 dd_ns245c1c33g0s090vfi.out 654,464 11-20-2019 04:57 347b3195 dd_ns245c1c33g0s095vfi.inp 4,297 11-18-2019 17:07 fbd7fcd9 dd_ns245c1c33g0s095vfi.out 654,316 11-20-2019 04:58 b784da9c dd_ns245c1c33g0s100vfi.inp 4,297 11-18-2019 17:08 9c613e6a dd_ns245c1c33g0s100vfi.out 654,851 11-20-2019 05:17 8a47180b
\\v1.2\\dd\\ns325\\ (18) 5,919,542 11-22-2019 12:48 dd_ns325c1c33g0s001vfi.inp 4,247 11-18-2019 16:02 56bb4095 dd_ns325c1c33g0s001vfi.out 653,574 11-19-2019 23:19 21cd6954 dd_ns325c1c33g0s005vfi.inp 4,247 11-18-2019 16:02 54ac13f3 dd_ns325c1c33g0s005vfi.out 653,864 11-19-2019 23:11 82873fc6 dd_ns325c1c33g0s010vfi.inp 4,247 11-18-2019 16:03 52e9d39b dd_ns325c1c33g0s010vfi.out 653,067 11-19-2019 22:53 2e5bcfd8 dd_ns325c1c33g0s030vfi.inp 4,247 11-18-2019 16:03 42792c5d dd_ns325c1c33g0s030vfi.out 653,367 11-19-2019 23:09 4554b410 dd_ns325c1c33g0s050vfi.inp 4,247 11-18-2019 16:03 be5508d8 dd_ns325c1c33g0s050vfi.out 653,784 11-19-2019 23:23 b91f37e7 dd_ns325c1c33g0s070vfi.inp 4,247 11-18-2019 16:03 81dcaffa dd_ns325c1c33g0s070vfi.out 653,136 11-19-2019 23:39 adaf719e dd_ns325c1c33g0s090vfi.inp 4,247 11-18-2019 16:03 5367b475 dd_ns325c1c33g0s090vfi.out 652,723 11-19-2019 23:37 fb9505a2 dd_ns325c1c33g0s095vfi.inp 4,247 11-18-2019 16:03 a466ff67 dd_ns325c1c33g0s095vfi.out 653,732 11-19-2019 23:40 4bab858e dd_ns325c1c33g0s100vfi.inp 4,247 11-18-2019 16:03 7d6c2730 dd_ns325c1c33g0s100vfi.out 654,072 11-19-2019 23:32 6aa1ce78
\\v1.2\\df\\ (0) 57,915,537 11-18-2019 17:08
\\v1.2\\df\\ha245\\ (22) 7,247,282 11-18-2019 20:33 df_ha245d1c33g0s0500hx.inp 4,276 11-18-2019 02:11 ce598497 df_ha245d1c33g0s0500hx.out 655,242 11-18-2019 13:03 3485fffd df_ha245d1c33g0s0600hx.inp 4,277 11-18-2019 02:11 93cce0bb df_ha245d1c33g0s0600hx.out 654,634 11-18-2019 13:03 4aaaa195 df_ha245d1c33g0s0700hx.inp 4,277 11-18-2019 02:11 00889cb5 df_ha245d1c33g0s0700hx.out 654,711 11-18-2019 13:02 f18a2da6 df_ha245d1c33g0s0800hx.inp 4,277 11-18-2019 02:11 680da38a df_ha245d1c33g0s0800hx.out 654,222 11-18-2019 13:03 e1439440 df_ha245d1c33g0s0900hx.inp 4,277 11-18-2019 02:11 18e54592 df_ha245d1c33g0s0900hx.out 654,231 11-18-2019 13:03 e3dc81bd df_ha245d1c33g0s1000hx.inp 4,281 11-18-2019 02:11 53d4c181 df_ha245d1c33g0s1000hx.out 653,993 11-18-2019 13:03 82d88efc df_ha245d1c33g0s1100hx.inp 4,281 11-18-2019 02:12 14dc0ada df_ha245d1c33g0s1100hx.out 654,586 11-18-2019 13:03 5c9b7a38 df_ha245d1c33g0s1200hx.inp 4,281 11-18-2019 02:12 099d67ba df_ha245d1c33g0s1200hx.out 654,366 11-18-2019 13:03 35492c2a df_ha245d1c33g0s1300hx.inp 4,281 11-18-2019 02:12 127418d8 df_ha245d1c33g0s1300hx.out 654,148 11-18-2019 13:06 be062e4f df_ha245d1c33g0s1400hx.inp 4,281 11-18-2019 02:12 f133f539 df_ha245d1c33g0s1400hx.out 655,131 11-18-2019 13:06 de9bfdec df_ha245d1c33g0s1500hx.inp 4,281 11-18-2019 02:12 e8eedee9 df_ha245d1c33g0s1500hx.out 654,948 11-18-2019 13:07 10073582
\\v1.2\\df\\ha325\\ (22) 7,234,211 11-18-2019 20:33 df_ha325d1c33g0s0500hx.inp 4,222 11-18-2019 00:17 2063af2c df_ha325d1c33g0s0500hx.out 653,383 11-18-2019 03:28 bd169d0c df_ha325d1c33g0s0600hx.inp 4,222 11-18-2019 00:18 ba6ff8c4 df_ha325d1c33g0s0600hx.out 653,597 11-18-2019 03:26 73de6311 df_ha325d1c33g0s0700hx.inp 4,222 11-18-2019 00:18 30ab8625
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
99 of 190 df_ha325d1c33g0s0700hx.out 654,037 11-18-2019 03:21 dea56b50 df_ha325d1c33g0s0800hx.inp 4,222 11-18-2019 00:18 e9f85009 df_ha325d1c33g0s0800hx.out 653,800 11-18-2019 03:22 38728c82 df_ha325d1c33g0s0900hx.inp 4,222 11-18-2019 00:18 e5abb9cf df_ha325d1c33g0s0900hx.out 652,327 11-18-2019 03:24 7c87b0b4 df_ha325d1c33g0s1000hx.inp 4,226 11-18-2019 00:18 38dfcf59 df_ha325d1c33g0s1000hx.out 653,132 11-18-2019 03:25 ac95e81f df_ha325d1c33g0s1100hx.inp 4,226 11-18-2019 00:18 cce77d05 df_ha325d1c33g0s1100hx.out 653,418 11-18-2019 03:25 f7ca95ce df_ha325d1c33g0s1200hx.inp 4,226 11-18-2019 00:18 54623053 df_ha325d1c33g0s1200hx.out 653,358 11-18-2019 03:27 d49b49e0 df_ha325d1c33g0s1300hx.inp 4,226 11-18-2019 00:18 d4c93bf0 df_ha325d1c33g0s1300hx.out 654,359 11-18-2019 03:28 2129b0b3 df_ha325d1c33g0s1400hx.inp 4,226 11-18-2019 00:18 c0ce878b df_ha325d1c33g0s1400hx.out 653,366 11-18-2019 03:31 fc76929c df_ha325d1c33g0s1500hx.inp 4,226 11-18-2019 00:18 13c67ee9 df_ha325d1c33g0s1500hx.out 652,968 11-18-2019 03:27 6726bd37
\\v1.2\\df\\hs245\\ (22) 7,247,012 11-20-2019 09:22 df_hs245d1c33g0s0500hx.inp 4,304 11-18-2019 14:36 a8ac0672 df_hs245d1c33g0s0500hx.out 653,507 11-19-2019 18:20 b12a7a68 df_hs245d1c33g0s0600hx.inp 4,305 11-18-2019 14:36 c27b8a96 df_hs245d1c33g0s0600hx.out 653,745 11-19-2019 18:37 8c24e890 df_hs245d1c33g0s0700hx.inp 4,305 11-18-2019 14:36 55c16263 df_hs245d1c33g0s0700hx.out 654,344 11-19-2019 18:18 da1bb7d4 df_hs245d1c33g0s0800hx.inp 4,305 11-18-2019 14:36 821e43b9 df_hs245d1c33g0s0800hx.out 654,127 11-19-2019 18:20 c00bbe5a df_hs245d1c33g0s0900hx.inp 4,305 11-18-2019 14:36 3737c57b df_hs245d1c33g0s0900hx.out 654,169 11-19-2019 18:33 ea7f379f df_hs245d1c33g0s1000hx.inp 4,309 11-18-2019 14:36 ee7ae9d3 df_hs245d1c33g0s1000hx.out 654,947 11-19-2019 18:23 26296137 df_hs245d1c33g0s1100hx.inp 4,309 11-18-2019 14:36 762360ae df_hs245d1c33g0s1100hx.out 655,063 11-19-2019 18:29 fb033967 df_hs245d1c33g0s1200hx.inp 4,309 11-18-2019 14:37 f35e43ad df_hs245d1c33g0s1200hx.out 654,548 11-19-2019 18:36 d459de1f df_hs245d1c33g0s1300hx.inp 4,309 11-18-2019 14:37 72c4a5a5 df_hs245d1c33g0s1300hx.out 654,778 11-19-2019 18:44 5a56721f df_hs245d1c33g0s1400hx.inp 4,309 11-18-2019 14:37 d9efee78 df_hs245d1c33g0s1400hx.out 655,959 11-19-2019 18:26 43005d07 df_hs245d1c33g0s1500hx.inp 4,309 11-18-2019 14:37 73e4cb2f df_hs245d1c33g0s1500hx.out 654,447 11-19-2019 18:29 980dc694
\\v1.2\\df\\hs325\\ (22) 7,231,530 11-20-2019 09:22 df_hs325d1c33g0s0500hx.inp 4,255 11-18-2019 12:48 91f7b584 df_hs325d1c33g0s0500hx.out 653,341 11-19-2019 13:08 f594bc4c df_hs325d1c33g0s0600hx.inp 4,255 11-18-2019 12:48 9a415da9 df_hs325d1c33g0s0600hx.out 653,302 11-19-2019 13:05 9b737f80 df_hs325d1c33g0s0700hx.inp 4,255 11-18-2019 12:48 94202bcb df_hs325d1c33g0s0700hx.out 653,214 11-19-2019 13:07 0860610c df_hs325d1c33g0s0800hx.inp 4,255 11-18-2019 12:49 642baaf5 df_hs325d1c33g0s0800hx.out 653,091 11-19-2019 12:56 e810d78c df_hs325d1c33g0s0900hx.inp 4,255 11-18-2019 12:49 93d83f85 df_hs325d1c33g0s0900hx.out 653,204 11-19-2019 13:05 9705bb63 df_hs325d1c33g0s1000hx.inp 4,259 11-18-2019 12:49 e787428d df_hs325d1c33g0s1000hx.out 652,569 11-19-2019 13:10 e2f9908d df_hs325d1c33g0s1100hx.inp 4,259 11-18-2019 12:49 00deb4bc df_hs325d1c33g0s1100hx.out 653,255 11-19-2019 13:15 81182f4a df_hs325d1c33g0s1200hx.inp 4,259 11-18-2019 12:49 b2926240 df_hs325d1c33g0s1200hx.out 653,924 11-19-2019 13:20 87b1078f df_hs325d1c33g0s1300hx.inp 4,259 11-18-2019 12:49 6532aadb df_hs325d1c33g0s1300hx.out 652,457 11-19-2019 13:18 3d5f954f df_hs325d1c33g0s1400hx.inp 4,259 11-18-2019 12:49 ba78a270 df_hs325d1c33g0s1400hx.out 652,972 11-19-2019 13:17 cea2d4b5 df_hs325d1c33g0s1500hx.inp 4,259 11-18-2019 12:49 9eb8fb53 df_hs325d1c33g0s1500hx.out 653,372 11-19-2019 13:19 4056d5f4
\\v1.2\\df\\na245\\ (22) 7,244,395 11-20-2019 09:22 df_na245d1c33g0s0500hx.inp 4,303 11-18-2019 11:26 6e2fb6e0 df_na245d1c33g0s0500hx.out 655,057 11-19-2019 05:43 d0a3e032 df_na245d1c33g0s0600hx.inp 4,304 11-18-2019 11:26 ab9e3182 df_na245d1c33g0s0600hx.out 654,425 11-19-2019 05:46 0a3c3ddf df_na245d1c33g0s0700hx.inp 4,304 11-18-2019 11:26 24cd438b df_na245d1c33g0s0700hx.out 654,758 11-19-2019 05:57 ff1dacde df_na245d1c33g0s0800hx.inp 4,304 11-18-2019 11:26 642018b6 df_na245d1c33g0s0800hx.out 653,408 11-19-2019 05:45 e1722a5f df_na245d1c33g0s0900hx.inp 4,304 11-18-2019 11:26 a07d00b7 df_na245d1c33g0s0900hx.out 654,323 11-19-2019 05:39 ff8aed17 df_na245d1c33g0s1000hx.inp 4,308 11-18-2019 11:26 3c413207
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
100 of 190 df_na245d1c33g0s1000hx.out 654,543 11-19-2019 05:41 fab52c6a df_na245d1c33g0s1100hx.inp 4,308 11-18-2019 11:26 fdc5367c df_na245d1c33g0s1100hx.out 654,156 11-19-2019 05:42 67216eab df_na245d1c33g0s1200hx.inp 4,308 11-18-2019 11:26 43c99550 df_na245d1c33g0s1200hx.out 654,353 11-19-2019 05:48 8950cb44 df_na245d1c33g0s1300hx.inp 4,308 11-18-2019 11:26 c759a09e df_na245d1c33g0s1300hx.out 653,424 11-19-2019 05:50 82804501 df_na245d1c33g0s1400hx.inp 4,308 11-18-2019 11:26 9ed52773 df_na245d1c33g0s1400hx.out 654,336 11-19-2019 05:50 c3a549a8 df_na245d1c33g0s1500hx.inp 4,308 11-18-2019 11:26 a1f650f2 df_na245d1c33g0s1500hx.out 654,245 11-19-2019 05:51 067c6b91
\\v1.2\\df\\na325\\ (22) 7,230,738 11-20-2019 09:22 df_na325d1c33g0s0500hx.inp 4,254 11-18-2019 10:23 d2c41249 df_na325d1c33g0s0500hx.out 652,453 11-18-2019 21:49 9f4a6b82 df_na325d1c33g0s0600hx.inp 4,254 11-18-2019 10:23 6e76f22d df_na325d1c33g0s0600hx.out 652,528 11-18-2019 21:39 5dfdeb16 df_na325d1c33g0s0700hx.inp 4,254 11-18-2019 10:23 ac620e90 df_na325d1c33g0s0700hx.out 653,178 11-18-2019 21:52 1c93b3c7 df_na325d1c33g0s0800hx.inp 4,254 11-18-2019 10:23 4d2b8368 df_na325d1c33g0s0800hx.out 652,630 11-18-2019 21:46 d8bd24dc df_na325d1c33g0s0900hx.inp 4,254 11-18-2019 10:23 86252e7a df_na325d1c33g0s0900hx.out 653,970 11-18-2019 21:48 9901b62e df_na325d1c33g0s1000hx.inp 4,258 11-18-2019 10:23 014bcd68 df_na325d1c33g0s1000hx.out 652,880 11-18-2019 21:50 ca138a3a df_na325d1c33g0s1100hx.inp 4,258 11-18-2019 10:23 75cd4c0c df_na325d1c33g0s1100hx.out 652,990 11-18-2019 21:51 dfa902c3 df_na325d1c33g0s1200hx.inp 4,258 11-18-2019 10:23 2efefda2 df_na325d1c33g0s1200hx.out 653,178 11-18-2019 21:52 fc04478a df_na325d1c33g0s1300hx.inp 4,258 11-18-2019 10:23 1ea4c28a df_na325d1c33g0s1300hx.out 653,501 11-18-2019 21:45 b75aa972 df_na325d1c33g0s1400hx.inp 4,258 11-18-2019 10:23 da2e1894 df_na325d1c33g0s1400hx.out 653,256 11-18-2019 21:53 9693c746 df_na325d1c33g0s1500hx.inp 4,258 11-18-2019 10:24 0453e768 df_na325d1c33g0s1500hx.out 653,356 11-18-2019 21:58 92980a71
\\v1.2\\df\\ns245\\ (22) 7,246,991 11-20-2019 09:22 df_ns245d1c33g0s0500hx.inp 4,304 11-18-2019 17:08 e2f08974 df_ns245d1c33g0s0500hx.out 653,787 11-20-2019 05:01 44b91257 df_ns245d1c33g0s0600hx.inp 4,305 11-18-2019 17:08 19bb7e83 df_ns245d1c33g0s0600hx.out 654,864 11-20-2019 05:00 d368ceeb df_ns245d1c33g0s0700hx.inp 4,305 11-18-2019 17:08 8e019676 df_ns245d1c33g0s0700hx.out 653,569 11-20-2019 05:18 b9624265 df_ns245d1c33g0s0800hx.inp 4,305 11-18-2019 17:08 59deb7ac df_ns245d1c33g0s0800hx.out 654,426 11-20-2019 05:00 3906f9fa df_ns245d1c33g0s0900hx.inp 4,305 11-18-2019 17:08 ecf7316e df_ns245d1c33g0s0900hx.out 654,314 11-20-2019 04:56 4ff8d5d1 df_ns245d1c33g0s1000hx.inp 4,309 11-18-2019 17:08 186c98e1 df_ns245d1c33g0s1000hx.out 654,444 11-20-2019 05:01 3b96febf df_ns245d1c33g0s1100hx.inp 4,309 11-18-2019 17:08 8035119c df_ns245d1c33g0s1100hx.out 655,430 11-20-2019 05:04 577054fd df_ns245d1c33g0s1200hx.inp 4,309 11-18-2019 17:08 0548329f df_ns245d1c33g0s1200hx.out 655,178 11-20-2019 05:08 9add04f7 df_ns245d1c33g0s1300hx.inp 4,309 11-18-2019 17:08 84d2d497 df_ns245d1c33g0s1300hx.out 654,293 11-20-2019 05:05 5a8094cc df_ns245d1c33g0s1400hx.inp 4,309 11-18-2019 17:09 2ff99f4a df_ns245d1c33g0s1400hx.out 654,570 11-20-2019 05:05 c23bd7ee df_ns245d1c33g0s1500hx.inp 4,309 11-18-2019 17:09 85f2ba1d df_ns245d1c33g0s1500hx.out 654,738 11-20-2019 05:08 39259485
\\v1.2\\df\\ns325\\ (22) 7,233,378 11-20-2019 09:22 df_ns325d1c33g0s0500hx.inp 4,255 11-18-2019 16:03 c9727d27 df_ns325d1c33g0s0500hx.out 653,021 11-19-2019 23:45 03adf56b df_ns325d1c33g0s0600hx.inp 4,255 11-18-2019 16:03 c2c4950a df_ns325d1c33g0s0600hx.out 652,155 11-19-2019 23:53 e3d8236c df_ns325d1c33g0s0700hx.inp 4,255 11-18-2019 16:03 cca5e368 df_ns325d1c33g0s0700hx.out 654,175 11-19-2019 23:39 a52caad6 df_ns325d1c33g0s0800hx.inp 4,255 11-18-2019 16:03 3cae6256 df_ns325d1c33g0s0800hx.out 652,869 11-19-2019 23:42 edab81d9 df_ns325d1c33g0s0900hx.inp 4,255 11-18-2019 16:04 cb5df726 df_ns325d1c33g0s0900hx.out 653,634 11-19-2019 23:41 482454bc df_ns325d1c33g0s1000hx.inp 4,259 11-18-2019 16:04 372e24bb df_ns325d1c33g0s1000hx.out 653,801 11-19-2019 23:42 aff1c12b df_ns325d1c33g0s1100hx.inp 4,259 11-18-2019 16:04 d077d28a df_ns325d1c33g0s1100hx.out 653,929 11-19-2019 23:45 c923e63a df_ns325d1c33g0s1200hx.inp 4,259 11-18-2019 16:04 623b0476 df_ns325d1c33g0s1200hx.out 653,176 11-19-2019 23:45 87e6426a df_ns325d1c33g0s1300hx.inp 4,259 11-18-2019 16:04 b59bcced
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
101 of 190 df_ns325d1c33g0s1300hx.out 653,281 11-19-2019 23:47 bc020ffc df_ns325d1c33g0s1400hx.inp 4,259 11-18-2019 16:04 6ad1c446 df_ns325d1c33g0s1400hx.out 653,455 11-19-2019 23:47 8195e86a df_ns325d1c33g0s1500hx.inp 4,259 11-18-2019 16:04 4e119d65 df_ns325d1c33g0s1500hx.out 653,053 11-19-2019 23:49 2eb28f2e
\\v1.2\\dh\\ (0) 47,401,519 11-18-2019 17:09
\\v1.2\\dh\\ha245\\ (18) 5,928,768 11-22-2019 12:48 dh_ha245d1c33g0s001vfio.inp 4,277 11-18-2019 02:12 ff6e265d dh_ha245d1c33g0s001vfio.out 654,242 11-18-2019 11:51 9b93b240 dh_ha245d1c33g0s005vfio.inp 4,277 11-18-2019 02:12 9269e2dd dh_ha245d1c33g0s005vfio.out 654,953 11-18-2019 11:41 55fb2840 dh_ha245d1c33g0s010vfio.inp 4,277 11-18-2019 02:12 e53ed87a dh_ha245d1c33g0s010vfio.out 655,044 11-18-2019 11:48 a25d0d1b dh_ha245d1c33g0s030vfio.inp 4,277 11-18-2019 02:12 6c64ae19 dh_ha245d1c33g0s030vfio.out 654,867 11-18-2019 12:12 329afdec dh_ha245d1c33g0s050vfio.inp 4,277 11-18-2019 02:12 713499b1 dh_ha245d1c33g0s050vfio.out 654,000 11-18-2019 12:33 7b1eb4b7 dh_ha245d1c33g0s070vfio.inp 4,277 11-18-2019 02:12 4a984586 dh_ha245d1c33g0s070vfio.out 655,282 11-18-2019 12:48 f70b0bca dh_ha245d1c33g0s090vfio.inp 4,277 11-18-2019 02:13 6178952f dh_ha245d1c33g0s090vfio.out 653,885 11-18-2019 12:55 01a9162d dh_ha245d1c33g0s095vfio.inp 4,277 11-18-2019 02:13 67e468ea dh_ha245d1c33g0s095vfio.out 653,774 11-18-2019 12:57 02f43903 dh_ha245d1c33g0s100vfio.inp 4,277 11-18-2019 02:13 18e54592 dh_ha245d1c33g0s100vfio.out 654,228 11-18-2019 12:58 aa7eaf75
\\v1.2\\dh\\ha325\\ (18) 5,918,514 11-22-2019 12:48 dh_ha325d1c33g0s001vfio.inp 4,222 11-18-2019 00:18 efc0841b dh_ha325d1c33g0s001vfio.out 652,940 11-18-2019 02:16 8a257309 dh_ha325d1c33g0s005vfio.inp 4,222 11-18-2019 00:18 68aa1ef2 dh_ha325d1c33g0s005vfio.out 653,235 11-18-2019 02:02 17e36696 dh_ha325d1c33g0s010vfio.inp 4,222 11-18-2019 00:19 a26ca9c0 dh_ha325d1c33g0s010vfio.out 653,814 11-18-2019 02:09 4fd062eb dh_ha325d1c33g0s030vfio.inp 4,222 11-18-2019 00:19 53f130e8 dh_ha325d1c33g0s030vfio.out 653,862 11-18-2019 02:37 5100f058 dh_ha325d1c33g0s050vfio.inp 4,222 11-18-2019 00:19 41e8a53e dh_ha325d1c33g0s050vfio.out 653,492 11-18-2019 03:00 69fe8d48 dh_ha325d1c33g0s070vfio.inp 4,222 11-18-2019 00:19 c0c77781 dh_ha325d1c33g0s070vfio.out 653,683 11-18-2019 03:15 dcee8009 dh_ha325d1c33g0s090vfio.inp 4,222 11-18-2019 00:19 a60c3bde dh_ha325d1c33g0s090vfio.out 653,950 11-18-2019 03:22 575269f4 dh_ha325d1c33g0s095vfio.inp 4,222 11-18-2019 00:19 565c3da1 dh_ha325d1c33g0s095vfio.out 653,210 11-18-2019 03:24 6488a0a7 dh_ha325d1c33g0s100vfio.inp 4,222 11-18-2019 00:19 e5abb9cf dh_ha325d1c33g0s100vfio.out 652,330 11-18-2019 03:24 cacddec5
\\v1.2\\dh\\hs245\\ (18) 5,929,912 11-22-2019 12:48 dh_hs245d1c33g0s001vfi.inp 4,305 11-18-2019 14:37 dfec3797 dh_hs245d1c33g0s001vfi.out 654,640 11-19-2019 18:14 433cc4e7 dh_hs245d1c33g0s005vfi.inp 4,305 11-18-2019 14:37 bb5e1ec7 dh_hs245d1c33g0s005vfi.out 655,115 11-19-2019 17:48 f4698cd2 dh_hs245d1c33g0s010vfi.inp 4,305 11-18-2019 14:37 d013d3e4 dh_hs245d1c33g0s010vfi.out 654,619 11-19-2019 17:54 dd82629e dh_hs245d1c33g0s030vfi.inp 4,305 11-18-2019 14:37 38daf7b1 dh_hs245d1c33g0s030vfi.out 654,264 11-19-2019 17:54 9a84c10a dh_hs245d1c33g0s050vfi.inp 4,305 11-18-2019 14:37 8ce64980 dh_hs245d1c33g0s050vfi.out 654,615 11-19-2019 18:13 3533d311 dh_hs245d1c33g0s070vfi.inp 4,305 11-18-2019 14:37 10430b76 dh_hs245d1c33g0s070vfi.out 654,938 11-19-2019 18:32 4f878fb6 dh_hs245d1c33g0s090vfi.inp 4,305 11-18-2019 14:37 846f7ebb dh_hs245d1c33g0s090vfi.out 654,067 11-19-2019 18:39 a4d8f89a dh_hs245d1c33g0s095vfi.inp 4,305 11-18-2019 14:38 e562fd8a dh_hs245d1c33g0s095vfi.out 654,738 11-19-2019 18:40 dcc8185d dh_hs245d1c33g0s100vfi.inp 4,305 11-18-2019 14:38 3737c57b dh_hs245d1c33g0s100vfi.out 654,171 11-19-2019 18:23 0749d243
\\v1.2\\dh\\hs325\\ (18) 5,920,969 11-22-2019 12:48 dh_hs325d1c33g0s001vfi.inp 4,255 11-18-2019 12:49 b83dd735 dh_hs325d1c33g0s001vfi.out 654,342 11-19-2019 12:52 5830492d dh_hs325d1c33g0s005vfi.inp 4,255 11-18-2019 12:49 4346b356 dh_hs325d1c33g0s005vfi.out 653,939 11-19-2019 12:37 698cf5c2 dh_hs325d1c33g0s010vfi.inp 4,255 11-18-2019 12:49 d1b8f325 dh_hs325d1c33g0s010vfi.out 652,841 11-19-2019 12:30 7fab62e8 dh_hs325d1c33g0s030vfi.inp 4,255 11-18-2019 12:50 d34feadf
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
102 of 190 dh_hs325d1c33g0s030vfi.out 653,738 11-19-2019 12:36 afbf3d64 dh_hs325d1c33g0s050vfi.inp 4,255 11-18-2019 12:50 16a4b6ee dh_hs325d1c33g0s050vfi.out 653,049 11-19-2019 12:56 55ac95bc dh_hs325d1c33g0s070vfi.inp 4,255 11-18-2019 12:50 0fa0c4cf dh_hs325d1c33g0s070vfi.out 653,654 11-19-2019 13:06 a2240ec3 dh_hs325d1c33g0s090vfi.inp 4,255 11-18-2019 12:50 d1a3669c dh_hs325d1c33g0s090vfi.out 653,609 11-19-2019 13:11 f048d636 dh_hs325d1c33g0s095vfi.inp 4,255 11-18-2019 12:50 28dcbf38 dh_hs325d1c33g0s095vfi.out 654,298 11-19-2019 13:15 e0e1cafe dh_hs325d1c33g0s100vfi.inp 4,255 11-18-2019 12:50 93d83f85 dh_hs325d1c33g0s100vfi.out 653,204 11-19-2019 13:24 464171e5
\\v1.2\\dh\\na245\\ (18) 5,932,311 11-22-2019 12:48 dh_na245d1c33g0s001vfio.inp 4,304 11-18-2019 11:27 6c63e423 dh_na245d1c33g0s001vfio.out 654,907 11-19-2019 04:30 a60d0f1f dh_na245d1c33g0s005vfio.inp 4,304 11-18-2019 11:27 eded3cce dh_na245d1c33g0s005vfio.out 655,354 11-19-2019 04:19 c62b82e6 dh_na245d1c33g0s010vfio.inp 4,304 11-18-2019 11:27 29f06d0c dh_na245d1c33g0s010vfio.out 655,468 11-19-2019 04:30 27acd880 dh_na245d1c33g0s030vfio.inp 4,304 11-18-2019 11:27 a272d892 dh_na245d1c33g0s030vfio.out 653,747 11-19-2019 05:16 5820503b dh_na245d1c33g0s050vfio.inp 4,304 11-18-2019 11:27 a57dd6c8 dh_na245d1c33g0s050vfio.out 655,736 11-19-2019 05:45 ad533dd0 dh_na245d1c33g0s070vfio.inp 4,304 11-18-2019 11:27 3008f2f6 dh_na245d1c33g0s070vfio.out 654,751 11-19-2019 05:52 930e3a94 dh_na245d1c33g0s090vfio.inp 4,304 11-18-2019 11:27 170a9c1d dh_na245d1c33g0s090vfio.out 654,498 11-19-2019 05:47 62db91b7 dh_na245d1c33g0s095vfio.inp 4,304 11-18-2019 11:27 47c05572 dh_na245d1c33g0s095vfio.out 654,789 11-19-2019 05:49 588cfd64 dh_na245d1c33g0s100vfio.inp 4,304 11-18-2019 11:27 a07d00b7 dh_na245d1c33g0s100vfio.out 654,325 11-19-2019 05:53 ae94760f
\\v1.2\\dh\\na325\\ (18) 5,918,499 11-22-2019 12:48 dh_na325d1c33g0s001vfio.inp 4,254 11-18-2019 10:24 e8979320 dh_na325d1c33g0s001vfio.out 653,303 11-18-2019 20:34 099ad527 dh_na325d1c33g0s005vfio.inp 4,254 11-18-2019 10:24 06a2e418 dh_na325d1c33g0s005vfio.out 653,888 11-18-2019 20:26 44dfc7e3 dh_na325d1c33g0s010vfio.inp 4,254 11-18-2019 10:24 18fe10aa dh_na325d1c33g0s010vfio.out 653,287 11-18-2019 20:37 9ba463b4 dh_na325d1c33g0s030vfio.inp 4,254 11-18-2019 10:24 2b86d9a9 dh_na325d1c33g0s030vfio.out 653,419 11-18-2019 21:16 0d0f3801 dh_na325d1c33g0s050vfio.inp 4,254 11-18-2019 10:24 5a59dd5b dh_na325d1c33g0s050vfio.out 653,201 11-18-2019 21:39 02168592 dh_na325d1c33g0s070vfio.inp 4,254 11-18-2019 10:24 f5a917e0 dh_na325d1c33g0s070vfio.out 652,973 11-18-2019 21:47 7849c8f5 dh_na325d1c33g0s090vfio.inp 4,254 11-18-2019 10:24 22b1c005 dh_na325d1c33g0s090vfio.out 653,549 11-18-2019 21:50 a48a4a90 dh_na325d1c33g0s095vfio.inp 4,254 11-18-2019 10:24 77b18544 dh_na325d1c33g0s095vfio.out 652,621 11-18-2019 21:48 facdda37 dh_na325d1c33g0s100vfio.inp 4,254 11-18-2019 10:24 86252e7a dh_na325d1c33g0s100vfio.out 653,972 11-18-2019 21:58 ea462a8d
\\v1.2\\dh\\ns245\\ (18) 5,929,162 11-22-2019 12:48 dh_ns245d1c33g0s001vfi.inp 4,305 11-18-2019 17:09 042cc382 dh_ns245d1c33g0s001vfi.out 655,184 11-20-2019 04:39 30fc6cba dh_ns245d1c33g0s005vfi.inp 4,305 11-18-2019 17:09 609eead2 dh_ns245d1c33g0s005vfi.out 654,586 11-20-2019 04:25 b72dc88c dh_ns245d1c33g0s010vfi.inp 4,305 11-18-2019 17:09 0bd327f1 dh_ns245d1c33g0s010vfi.out 654,820 11-20-2019 04:18 2b23ece0 dh_ns245d1c33g0s030vfi.inp 4,305 11-18-2019 17:09 e31a03a4 dh_ns245d1c33g0s030vfi.out 653,929 11-20-2019 04:38 94d676d1 dh_ns245d1c33g0s050vfi.inp 4,305 11-18-2019 17:09 5726bd95 dh_ns245d1c33g0s050vfi.out 654,369 11-20-2019 04:48 097cfb39 dh_ns245d1c33g0s070vfi.inp 4,305 11-18-2019 17:09 cb83ff63 dh_ns245d1c33g0s070vfi.out 654,407 11-20-2019 04:57 93075337 dh_ns245d1c33g0s090vfi.inp 4,305 11-18-2019 17:09 5faf8aae dh_ns245d1c33g0s090vfi.out 654,287 11-20-2019 05:00 8e3b0e13 dh_ns245d1c33g0s095vfi.inp 4,305 11-18-2019 17:09 3ea2099f dh_ns245d1c33g0s095vfi.out 654,518 11-20-2019 05:03 8bc92c69 dh_ns245d1c33g0s100vfi.inp 4,305 11-18-2019 17:10 ecf7316e dh_ns245d1c33g0s100vfi.out 654,317 11-20-2019 05:05 16ba8bae
\\v1.2\\dh\\ns325\\ (18) 5,923,384 11-22-2019 12:48 dh_ns325d1c33g0s001vfi.inp 4,255 11-18-2019 16:04 e0b81f96 dh_ns325d1c33g0s001vfi.out 654,035 11-19-2019 23:26 342fcd54 dh_ns325d1c33g0s005vfi.inp 4,255 11-18-2019 16:04 1bc37bf5 dh_ns325d1c33g0s005vfi.out 654,941 11-19-2019 23:14 90074269
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
103 of 190 dh_ns325d1c33g0s010vfi.inp 4,255 11-18-2019 16:04 893d3b86 dh_ns325d1c33g0s010vfi.out 653,692 11-19-2019 23:00 eac54026 dh_ns325d1c33g0s030vfi.inp 4,255 11-18-2019 16:04 8bca227c dh_ns325d1c33g0s030vfi.out 653,409 11-19-2019 23:07 a7527c26 dh_ns325d1c33g0s050vfi.inp 4,255 11-18-2019 16:05 4e217e4d dh_ns325d1c33g0s050vfi.out 653,200 11-19-2019 23:31 9170c9bb dh_ns325d1c33g0s070vfi.inp 4,255 11-18-2019 16:05 57250c6c dh_ns325d1c33g0s070vfi.out 654,638 11-19-2019 23:42 b8515880 dh_ns325d1c33g0s090vfi.inp 4,255 11-18-2019 16:05 8926ae3f dh_ns325d1c33g0s090vfi.out 653,971 11-19-2019 23:48 6030342c dh_ns325d1c33g0s095vfi.inp 4,255 11-18-2019 16:05 7059779b dh_ns325d1c33g0s095vfi.out 653,571 11-19-2019 23:41 67d793d3 dh_ns325d1c33g0s100vfi.inp 4,255 11-18-2019 16:05 cb5df726 dh_ns325d1c33g0s100vfi.out 653,632 11-19-2019 23:40 712b4488
\\v1.2\\dj\\ (0) 28,895,474 11-18-2019 15:32
\\v1.2\\dj\\ha245\\ (22) 7,211,812 11-18-2019 20:33 dj_ha245a1c33g1s0500hx.inp 3,894 11-18-2019 09:41 ba2a899b dj_ha245a1c33g1s0500hx.out 651,871 11-18-2019 12:54 857316ec dj_ha245a1c33g1s0600hx.inp 3,895 11-18-2019 09:41 76156f8e dj_ha245a1c33g1s0600hx.out 651,843 11-18-2019 12:43 74e7ee1c dj_ha245a1c33g1s0700hx.inp 3,895 11-18-2019 09:41 fa5d6c05 dj_ha245a1c33g1s0700hx.out 651,448 11-18-2019 12:56 d2f5eb93 dj_ha245a1c33g1s0800hx.inp 3,895 11-18-2019 09:41 f445daba dj_ha245a1c33g1s0800hx.out 651,876 11-18-2019 12:50 466a30b1 dj_ha245a1c33g1s0900hx.inp 3,895 11-18-2019 09:41 e3824977 dj_ha245a1c33g1s0900hx.out 651,784 11-18-2019 12:49 bb2141aa dj_ha245a1c33g1s1000hx.inp 3,899 11-18-2019 09:41 52ca5387 dj_ha245a1c33g1s1000hx.out 650,946 11-18-2019 12:58 1453b42f dj_ha245a1c33g1s1100hx.inp 3,899 11-18-2019 09:41 007d28ef dj_ha245a1c33g1s1100hx.out 652,000 11-18-2019 12:51 ab5d96bc dj_ha245a1c33g1s1200hx.inp 3,899 11-18-2019 09:41 dc1fea32 dj_ha245a1c33g1s1200hx.out 652,008 11-18-2019 12:52 60754876 dj_ha245a1c33g1s1300hx.inp 3,899 11-18-2019 09:41 a452987e dj_ha245a1c33g1s1300hx.out 651,316 11-18-2019 12:54 de473a88 dj_ha245a1c33g1s1400hx.inp 3,899 11-18-2019 09:41 df38fb3d dj_ha245a1c33g1s1400hx.out 652,027 11-18-2019 12:54 7a65d1eb dj_ha245a1c33g1s1500hx.inp 3,899 11-18-2019 09:42 6b5399b4 dj_ha245a1c33g1s1500hx.out 651,825 11-18-2019 12:55 7f56e26c
\\v1.2\\dj\\ha325\\ (22) 7,235,163 11-18-2019 20:33 dj_ha325a1c33g1s0500hx.inp 4,082 11-18-2019 01:32 34a418c8 dj_ha325a1c33g1s0500hx.out 654,157 11-18-2019 07:00 7a3e9b08 dj_ha325a1c33g1s0600hx.inp 4,082 11-18-2019 01:32 b63a0221 dj_ha325a1c33g1s0600hx.out 653,562 11-18-2019 06:55 8802d8e0 dj_ha325a1c33g1s0700hx.inp 4,082 11-18-2019 01:32 015bba34 dj_ha325a1c33g1s0700hx.out 653,575 11-18-2019 06:59 dd2dbdab dj_ha325a1c33g1s0800hx.inp 4,082 11-18-2019 01:33 970727ee dj_ha325a1c33g1s0800hx.out 653,935 11-18-2019 06:52 632ecd5d dj_ha325a1c33g1s0900hx.inp 4,082 11-18-2019 01:33 8fd1e796 dj_ha325a1c33g1s0900hx.out 654,004 11-18-2019 07:06 4b892471 dj_ha325a1c33g1s1000hx.inp 4,086 11-18-2019 01:33 615dfe2b dj_ha325a1c33g1s1000hx.out 653,603 11-18-2019 06:58 a4617321 dj_ha325a1c33g1s1100hx.inp 4,086 11-18-2019 01:33 bd8ffb62 dj_ha325a1c33g1s1100hx.out 652,715 11-18-2019 07:02 9d311118 dj_ha325a1c33g1s1200hx.inp 4,086 11-18-2019 01:33 e8222aeb dj_ha325a1c33g1s1200hx.out 653,518 11-18-2019 07:04 e8988484 dj_ha325a1c33g1s1300hx.inp 4,086 11-18-2019 01:33 a7be4ec9 dj_ha325a1c33g1s1300hx.out 653,796 11-18-2019 07:04 4a42e1e7 dj_ha325a1c33g1s1400hx.inp 4,086 11-18-2019 01:33 b362585b dj_ha325a1c33g1s1400hx.out 654,031 11-18-2019 07:12 d38fabc1 dj_ha325a1c33g1s1500hx.inp 4,085 11-18-2019 01:33 f3e86807 dj_ha325a1c33g1s1500hx.out 653,342 11-18-2019 06:58 0164091f
\\v1.2\\dj\\na245\\ (22) 7,213,315 11-20-2019 09:22 dj_na245a1c33g1s0500hx.inp 3,894 11-18-2019 11:50 8b405c0d dj_na245a1c33g1s0500hx.out 651,786 11-19-2019 05:44 259aeae4 dj_na245a1c33g1s0600hx.inp 3,895 11-18-2019 11:50 9eddf8d0 dj_na245a1c33g1s0600hx.out 652,059 11-19-2019 05:42 857a00e3 dj_na245a1c33g1s0700hx.inp 3,895 11-18-2019 11:50 1295fb5b dj_na245a1c33g1s0700hx.out 651,342 11-19-2019 05:44 f31d89c7 dj_na245a1c33g1s0800hx.inp 3,895 11-18-2019 11:50 1c8d4de4 dj_na245a1c33g1s0800hx.out 651,760 11-19-2019 05:44 48518439 dj_na245a1c33g1s0900hx.inp 3,895 11-18-2019 11:50 0b4ade29 dj_na245a1c33g1s0900hx.out 652,009 11-19-2019 05:53 3488515e dj_na245a1c33g1s1000hx.inp 3,899 11-18-2019 11:50 25318291
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
104 of 190 dj_na245a1c33g1s1000hx.out 651,534 11-19-2019 05:48 cb410901 dj_na245a1c33g1s1100hx.inp 3,899 11-18-2019 11:50 7786f9f9 dj_na245a1c33g1s1100hx.out 652,166 11-19-2019 05:48 fbda7dd9 dj_na245a1c33g1s1200hx.inp 3,899 11-18-2019 11:51 abe43b24 dj_na245a1c33g1s1200hx.out 651,671 11-19-2019 05:55 de7169ca dj_na245a1c33g1s1300hx.inp 3,899 11-18-2019 11:51 d3a94968 dj_na245a1c33g1s1300hx.out 651,451 11-19-2019 05:56 2e5b7e62 dj_na245a1c33g1s1400hx.inp 3,899 11-18-2019 11:51 a8c32a2b dj_na245a1c33g1s1400hx.out 651,743 11-19-2019 05:43 2070375a dj_na245a1c33g1s1500hx.inp 3,899 11-18-2019 11:51 1ca848a2 dj_na245a1c33g1s1500hx.out 652,926 11-19-2019 06:03 a278bf7c
\\v1.2\\dj\\na325\\ (22) 7,235,184 11-20-2019 09:22 dj_na325a1c33g1s0500hx.inp 4,114 11-18-2019 10:46 5dbbdf23 dj_na325a1c33g1s0500hx.out 653,463 11-18-2019 21:46 334d902b dj_na325a1c33g1s0600hx.inp 4,114 11-18-2019 10:46 e97a5bef dj_na325a1c33g1s0600hx.out 653,340 11-18-2019 21:46 8c2ad566 dj_na325a1c33g1s0700hx.inp 4,114 11-18-2019 10:46 e348acac dj_na325a1c33g1s0700hx.out 653,446 11-18-2019 21:45 9c9d3314 dj_na325a1c33g1s0800hx.inp 4,114 11-18-2019 10:46 1c741cd0 dj_na325a1c33g1s0800hx.out 653,643 11-18-2019 21:46 065707ae dj_na325a1c33g1s0900hx.inp 4,114 11-18-2019 10:46 6e09f500 dj_na325a1c33g1s0900hx.out 653,658 11-18-2019 21:46 16d63a23 dj_na325a1c33g1s1000hx.inp 4,118 11-18-2019 10:46 71fa88fa dj_na325a1c33g1s1000hx.out 652,962 11-18-2019 21:50 adee2a2a dj_na325a1c33g1s1100hx.inp 4,118 11-18-2019 10:46 d448c037 dj_na325a1c33g1s1100hx.out 653,768 11-18-2019 21:50 494cc98b dj_na325a1c33g1s1200hx.inp 4,118 11-18-2019 10:46 2cf74c08 dj_na325a1c33g1s1200hx.out 653,765 11-18-2019 21:50 2eaedd29 dj_na325a1c33g1s1300hx.inp 4,118 11-18-2019 10:46 8e75229f dj_na325a1c33g1s1300hx.out 654,510 11-18-2019 21:53 e01cfa2f dj_na325a1c33g1s1400hx.inp 4,118 11-18-2019 10:46 98d23cea dj_na325a1c33g1s1400hx.out 653,744 11-18-2019 22:38 247091a0 dj_na325a1c33g1s1500hx.inp 4,117 11-18-2019 10:47 2da86a46 dj_na325a1c33g1s1500hx.out 653,608 11-18-2019 21:55 236ef457
\\v1.2\\dl\\ (0) 23,644,987 11-18-2019 15:32
\\v1.2\\dl\\ha245\\ (18) 5,903,709 11-22-2019 12:48 dl_ha245a1c33g1s001vfio.inp 3,895 11-18-2019 09:42 00905cc3 dl_ha245a1c33g1s001vfio.out 652,146 11-18-2019 12:09 45410120 dl_ha245a1c33g1s005vfio.inp 3,895 11-18-2019 09:42 8941f49c dl_ha245a1c33g1s005vfio.out 652,453 11-18-2019 11:52 a3e5d2b8 dl_ha245a1c33g1s010vfio.inp 3,895 11-18-2019 09:42 aadf8a0a dl_ha245a1c33g1s010vfio.out 651,473 11-18-2019 12:02 98e2a268 dl_ha245a1c33g1s030vfio.inp 3,895 11-18-2019 09:42 84b63bb4 dl_ha245a1c33g1s030vfio.out 652,093 11-18-2019 12:24 dcd0d6d2 dl_ha245a1c33g1s050vfio.inp 3,895 11-18-2019 09:42 853b50d3 dl_ha245a1c33g1s050vfio.out 652,705 11-18-2019 12:36 03dfa03d dl_ha245a1c33g1s070vfio.inp 3,895 11-18-2019 09:42 b55a012b dl_ha245a1c33g1s070vfio.out 652,006 11-18-2019 12:44 b2c8f2af dl_ha245a1c33g1s090vfio.inp 3,895 11-18-2019 09:42 84455d1c dl_ha245a1c33g1s090vfio.out 652,292 11-18-2019 12:49 85addc79 dl_ha245a1c33g1s095vfio.inp 3,895 11-18-2019 09:42 caf82a6b dl_ha245a1c33g1s095vfio.out 651,698 11-18-2019 12:56 898d4c92 dl_ha245a1c33g1s100vfio.inp 3,895 11-18-2019 09:42 e3824977 dl_ha245a1c33g1s100vfio.out 651,788 11-18-2019 12:53 464143fb
\\v1.2\\dl\\ha325\\ (18) 5,922,696 11-22-2019 12:48 dl_ha325a1c33g1s001vfio.inp 4,082 11-18-2019 01:33 fdee1f85 dl_ha325a1c33g1s001vfio.out 654,311 11-18-2019 06:35 4ca584f5 dl_ha325a1c33g1s005vfio.inp 4,082 11-18-2019 01:33 3a1aaad1 dl_ha325a1c33g1s005vfio.out 654,142 11-18-2019 06:09 2566ccce dl_ha325a1c33g1s010vfio.inp 4,082 11-18-2019 01:33 ff152ea3 dl_ha325a1c33g1s010vfio.out 654,214 11-18-2019 06:15 e8abbbe8 dl_ha325a1c33g1s030vfio.inp 4,082 11-18-2019 01:33 01b8939f dl_ha325a1c33g1s030vfio.out 653,906 11-18-2019 06:49 dc9deabb dl_ha325a1c33g1s050vfio.inp 4,082 11-18-2019 01:34 d94db152 dl_ha325a1c33g1s050vfio.out 653,359 11-18-2019 07:20 1e7a5a91 dl_ha325a1c33g1s070vfio.inp 4,082 11-18-2019 01:34 5dfaf110 dl_ha325a1c33g1s070vfio.out 654,486 11-18-2019 07:46 be97aab6 dl_ha325a1c33g1s090vfio.inp 4,082 11-18-2019 01:34 68e9f693 dl_ha325a1c33g1s090vfio.out 653,523 11-18-2019 07:20 3263d2ec dl_ha325a1c33g1s095vfio.inp 4,082 11-18-2019 01:34 7b05b49a dl_ha325a1c33g1s095vfio.out 654,011 11-18-2019 07:52 04155016 dl_ha325a1c33g1s100vfio.inp 4,082 11-18-2019 01:34 8fd1e796 dl_ha325a1c33g1s100vfio.out 654,006 11-18-2019 07:42 a18463ba
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
105 of 190
\\v1.2\\dl\\na245\\ (18) 5,900,428 11-22-2019 12:48 dl_na245a1c33g1s001vfio.inp 3,895 11-18-2019 11:51 e858cb9d dl_na245a1c33g1s001vfio.out 652,556 11-19-2019 05:12 00bdfba4 dl_na245a1c33g1s005vfio.inp 3,895 11-18-2019 11:51 618963c2 dl_na245a1c33g1s005vfio.out 651,668 11-19-2019 04:47 f76e4394 dl_na245a1c33g1s010vfio.inp 3,895 11-18-2019 11:51 42171d54 dl_na245a1c33g1s010vfio.out 651,476 11-19-2019 04:58 3c3581ef dl_na245a1c33g1s030vfio.inp 3,895 11-18-2019 11:51 6c7eacea dl_na245a1c33g1s030vfio.out 651,092 11-19-2019 05:21 5a5af564 dl_na245a1c33g1s050vfio.inp 3,895 11-18-2019 11:51 6df3c78d dl_na245a1c33g1s050vfio.out 651,562 11-19-2019 05:36 b86b1477 dl_na245a1c33g1s070vfio.inp 3,895 11-18-2019 11:51 5d929675 dl_na245a1c33g1s070vfio.out 651,353 11-19-2019 05:46 f396f396 dl_na245a1c33g1s090vfio.inp 3,895 11-18-2019 11:51 6c8dca42 dl_na245a1c33g1s090vfio.out 652,236 11-19-2019 05:51 bd09a882 dl_na245a1c33g1s095vfio.inp 3,895 11-18-2019 11:52 2230bd35 dl_na245a1c33g1s095vfio.out 651,419 11-19-2019 05:53 b611a4b0 dl_na245a1c33g1s100vfio.inp 3,895 11-18-2019 11:52 0b4ade29 dl_na245a1c33g1s100vfio.out 652,011 11-19-2019 05:54 2a1ca710
\\v1.2\\dl\\na325\\ (18) 5,918,154 11-22-2019 12:48 dl_na325a1c33g1s001vfio.inp 4,114 11-18-2019 10:47 14421906 dl_na325a1c33g1s001vfio.out 653,708 11-18-2019 21:22 99a6f131 dl_na325a1c33g1s005vfio.inp 4,114 11-18-2019 10:47 95771d8c dl_na325a1c33g1s005vfio.out 654,047 11-18-2019 20:45 427099a5 dl_na325a1c33g1s010vfio.inp 4,114 11-18-2019 10:47 806d47c5 dl_na325a1c33g1s010vfio.out 653,141 11-18-2019 20:54 72936dcd dl_na325a1c33g1s030vfio.inp 4,114 11-18-2019 10:47 5ca683ce dl_na325a1c33g1s030vfio.out 653,050 11-18-2019 21:18 0a8a6cc0 dl_na325a1c33g1s050vfio.inp 4,114 11-18-2019 10:47 6c2a2c46 dl_na325a1c33g1s050vfio.out 653,911 11-18-2019 21:33 90fc5be1 dl_na325a1c33g1s070vfio.inp 4,114 11-18-2019 10:47 5b7d3c22 dl_na325a1c33g1s070vfio.out 653,185 11-18-2019 21:40 a47cc934 dl_na325a1c33g1s090vfio.inp 4,114 11-18-2019 10:47 d1184144 dl_na325a1c33g1s090vfio.out 652,938 11-18-2019 21:52 e297e04d dl_na325a1c33g1s095vfio.inp 4,114 11-18-2019 10:47 1f241088 dl_na325a1c33g1s095vfio.out 653,489 11-18-2019 21:54 98471b6a dl_na325a1c33g1s100vfio.inp 4,114 11-18-2019 10:47 6e09f500 dl_na325a1c33g1s100vfio.out 653,659 11-18-2019 21:52 dd90c136
\\v1.2\\ea\\ (0) 165,975,312 11-18-2019 17:10
\\v1.2\\ea\\ha245\\ (66) 19,992,698 11-18-2019 20:33 ea_ha245a2c51g1s0500hx.inp 3,883 11-18-2019 02:13 719410bd ea_ha245a2c51g1s0500hx.out 650,776 11-18-2019 12:45 c629ff52 ea_ha245a2c51g1s0600hx.inp 3,884 11-18-2019 02:13 0b3295a1 ea_ha245a2c51g1s0600hx.out 650,293 11-18-2019 13:02 4c945de8 ea_ha245a2c51g1s0700hx.inp 3,884 11-18-2019 02:13 a8f9af27 ea_ha245a2c51g1s0700hx.out 650,102 11-18-2019 13:06 4f2570d3 ea_ha245a2c51g1s0800hx.inp 3,884 11-18-2019 02:13 a55b01f2 ea_ha245a2c51g1s0800hx.out 650,834 11-18-2019 13:06 a82d19ef ea_ha245a2c51g1s0900hx.inp 3,884 11-18-2019 02:13 26125acf ea_ha245a2c51g1s0900hx.out 651,262 11-18-2019 12:47 a73044c9 ea_ha245a2c51g1s1000hx.inp 3,888 11-18-2019 02:13 7a8f116f ea_ha245a2c51g1s1000hx.out 651,375 11-18-2019 12:51 6f8b33d1 ea_ha245a2c51g1s1100hx.inp 3,888 11-18-2019 02:13 2931f2cc ea_ha245a2c51g1s1100hx.out 650,870 11-18-2019 12:54 53bb19fd ea_ha245a2c51g1s1200hx.inp 3,888 11-18-2019 02:13 529f2ad7 ea_ha245a2c51g1s1200hx.out 650,711 11-18-2019 12:52 2dbf3f62 ea_ha245a2c51g1s1300hx.inp 3,888 11-18-2019 02:14 2bd8e65d ea_ha245a2c51g1s1300hx.out 650,605 11-18-2019 13:08 ee1da8cc ea_ha245a2c51g1s1400hx.inp 3,888 11-18-2019 02:14 2679ee1d ea_ha245a2c51g1s1400hx.out 651,310 11-18-2019 13:11 88f91520 ea_ha245a2c51g1s1500hx.inp 3,888 11-18-2019 02:14 24e1333c ea_ha245a2c51g1s1500hx.out 650,593 11-18-2019 13:23 b2c48bfc ea_ha245a2c51g2s0500hx.inp 3,881 11-18-2019 02:14 b4d86d6a ea_ha245a2c51g2s0500hx.out 503,815 11-18-2019 14:38 5c634fbd ea_ha245a2c51g2s0600hx.inp 3,882 11-18-2019 02:14 17f33260 ea_ha245a2c51g2s0600hx.out 504,678 11-18-2019 14:47 03e6b3a5 ea_ha245a2c51g2s0700hx.inp 3,882 11-18-2019 02:14 64adfbe3 ea_ha245a2c51g2s0700hx.out 504,545 11-18-2019 15:02 aeeb44b6 ea_ha245a2c51g2s0800hx.inp 3,882 11-18-2019 02:14 6e4d4736 ea_ha245a2c51g2s0800hx.out 504,214 11-18-2019 15:14 d7149f18 ea_ha245a2c51g2s0900hx.inp 3,882 11-18-2019 02:14 6fb86e83 ea_ha245a2c51g2s0900hx.out 505,489 11-18-2019 15:01 f851d9ad ea_ha245a2c51g2s1000hx.inp 3,886 11-18-2019 02:14 1215d697
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
106 of 190 ea_ha245a2c51g2s1000hx.out 504,286 11-18-2019 15:09 b283ef18 ea_ha245a2c51g2s1100hx.inp 3,886 11-18-2019 02:14 2138d766 ea_ha245a2c51g2s1100hx.out 504,104 11-18-2019 15:15 29a32966 ea_ha245a2c51g2s1200hx.inp 3,886 11-18-2019 02:14 fa71a26e ea_ha245a2c51g2s1200hx.out 504,387 11-18-2019 15:14 9e6893b8 ea_ha245a2c51g2s1300hx.inp 3,886 11-18-2019 02:14 d5df6f70 ea_ha245a2c51g2s1300hx.out 504,305 11-18-2019 15:21 c1c074ae ea_ha245a2c51g2s1400hx.inp 3,886 11-18-2019 02:15 420ee4ba ea_ha245a2c51g2s1400hx.out 504,046 11-18-2019 15:18 bf236a7b ea_ha245a2c51g2s1500hx.inp 3,886 11-18-2019 02:15 de901ddb ea_ha245a2c51g2s1500hx.out 504,928 11-18-2019 15:13 05d8b12f ea_ha245a2c51g3s0500hx.inp 3,878 11-18-2019 02:15 3d25896b ea_ha245a2c51g3s0500hx.out 651,153 11-18-2019 14:56 2b96385b ea_ha245a2c51g3s0600hx.inp 3,879 11-18-2019 02:15 9ca3c61a ea_ha245a2c51g3s0600hx.out 650,698 11-18-2019 14:55 b913a788 ea_ha245a2c51g3s0700hx.inp 3,879 11-18-2019 02:15 6e903b27 ea_ha245a2c51g3s0700hx.out 650,970 11-18-2019 14:57 b07ea35f ea_ha245a2c51g3s0800hx.inp 3,879 11-18-2019 02:15 58fcaf4d ea_ha245a2c51g3s0800hx.out 649,944 11-18-2019 15:10 1fec822c ea_ha245a2c51g3s0900hx.inp 3,879 11-18-2019 02:15 98dc1835 ea_ha245a2c51g3s0900hx.out 650,652 11-18-2019 15:04 4c61eefb ea_ha245a2c51g3s1000hx.inp 3,883 11-18-2019 02:15 6b5f89c1 ea_ha245a2c51g3s1000hx.out 651,179 11-18-2019 14:57 39c83cc8 ea_ha245a2c51g3s1100hx.inp 3,883 11-18-2019 02:15 1e775961 ea_ha245a2c51g3s1100hx.out 650,433 11-18-2019 15:01 02f363b3 ea_ha245a2c51g3s1200hx.inp 3,883 11-18-2019 02:15 77939c6c ea_ha245a2c51g3s1200hx.out 650,948 11-18-2019 15:02 f20ba6bf ea_ha245a2c51g3s1300hx.inp 3,883 11-18-2019 02:15 f2b3c77e ea_ha245a2c51g3s1300hx.out 650,552 11-18-2019 15:24 5d0e26e6 ea_ha245a2c51g3s1400hx.inp 3,883 11-18-2019 02:15 ee353fc0 ea_ha245a2c51g3s1400hx.out 649,745 11-18-2019 15:03 0523647d ea_ha245a2c51g3s1500hx.inp 3,883 11-18-2019 02:16 6795d9dc ea_ha245a2c51g3s1500hx.out 650,732 11-18-2019 15:14 f6a83b15
\\v1.2\\ea\\ha325\\ (66) 20,691,662 11-18-2019 20:33 ea_ha325a2c51g1s0500hx.inp 3,829 11-18-2019 00:19 0effba84 ea_ha325a2c51g1s0500hx.out 649,944 11-18-2019 03:16 ab7cf1ec ea_ha325a2c51g1s0600hx.inp 3,829 11-18-2019 00:19 1a12fc8c ea_ha325a2c51g1s0600hx.out 649,602 11-18-2019 03:17 a05076d0 ea_ha325a2c51g1s0700hx.inp 3,829 11-18-2019 00:19 05a0c681 ea_ha325a2c51g1s0700hx.out 650,120 11-18-2019 03:19 d4df00c4 ea_ha325a2c51g1s0800hx.inp 3,829 11-18-2019 00:19 755bf3b0 ea_ha325a2c51g1s0800hx.out 649,923 11-18-2019 03:18 c2b3091c ea_ha325a2c51g1s0900hx.inp 3,829 11-18-2019 00:20 bcfadfe8 ea_ha325a2c51g1s0900hx.out 649,857 11-18-2019 03:14 2725409c ea_ha325a2c51g1s1000hx.inp 3,833 11-18-2019 00:20 5e735ce3 ea_ha325a2c51g1s1000hx.out 649,569 11-18-2019 03:17 b5b80116 ea_ha325a2c51g1s1100hx.inp 3,833 11-18-2019 00:20 1d1bf30b ea_ha325a2c51g1s1100hx.out 649,553 11-18-2019 03:21 b1328eca ea_ha325a2c51g1s1200hx.inp 3,833 11-18-2019 00:20 60014ffa ea_ha325a2c51g1s1200hx.out 649,497 11-18-2019 03:22 0cf093d5 ea_ha325a2c51g1s1300hx.inp 3,833 11-18-2019 00:20 26dd3687 ea_ha325a2c51g1s1300hx.out 650,233 11-18-2019 03:19 df7fde9a ea_ha325a2c51g1s1400hx.inp 3,833 11-18-2019 00:20 d880dca0 ea_ha325a2c51g1s1400hx.out 649,825 11-18-2019 03:27 452105e8 ea_ha325a2c51g1s1500hx.inp 3,833 11-18-2019 00:20 79d42384 ea_ha325a2c51g1s1500hx.out 650,560 11-18-2019 03:28 2504485b ea_ha325a2c51g2s0500hx.inp 3,827 11-18-2019 00:20 459cc294 ea_ha325a2c51g2s0500hx.out 503,406 11-18-2019 04:18 2a7c3a69 ea_ha325a2c51g2s0600hx.inp 3,827 11-18-2019 00:20 c97c81f6 ea_ha325a2c51g2s0600hx.out 503,154 11-18-2019 04:17 90c8036d ea_ha325a2c51g2s0700hx.inp 3,827 11-18-2019 00:20 e4581212 ea_ha325a2c51g2s0700hx.out 502,712 11-18-2019 04:12 e455444f ea_ha325a2c51g2s0800hx.inp 3,827 11-18-2019 00:20 d0d4d441 ea_ha325a2c51g2s0800hx.out 503,440 11-18-2019 04:05 64c9e120 ea_ha325a2c51g2s0900hx.inp 3,827 11-18-2019 00:21 2888daea ea_ha325a2c51g2s0900hx.out 503,350 11-18-2019 04:05 80d27448 ea_ha325a2c51g2s1000hx.inp 3,831 11-18-2019 00:21 75f32be2 ea_ha325a2c51g2s1000hx.out 503,577 11-18-2019 04:06 1473c4be ea_ha325a2c51g2s1100hx.inp 3,831 11-18-2019 00:21 fade86b2 ea_ha325a2c51g2s1100hx.out 649,906 11-18-2019 04:02 a3cadba6 ea_ha325a2c51g2s1200hx.inp 3,831 11-18-2019 00:21 5a31c68b ea_ha325a2c51g2s1200hx.out 648,907 11-18-2019 04:02 e56b1534 ea_ha325a2c51g2s1300hx.inp 3,831 11-18-2019 00:21 dadfd4f5 ea_ha325a2c51g2s1300hx.out 649,647 11-18-2019 04:05 aa1d1c2f ea_ha325a2c51g2s1400hx.inp 3,831 11-18-2019 00:21 080ff853 ea_ha325a2c51g2s1400hx.out 649,582 11-18-2019 04:03 1b7574fb ea_ha325a2c51g2s1500hx.inp 3,831 11-18-2019 00:21 2efda074 ea_ha325a2c51g2s1500hx.out 649,930 11-18-2019 04:04 c41a183e ea_ha325a2c51g3s0500hx.inp 3,824 11-18-2019 00:21 c0647c8e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
107 of 190 ea_ha325a2c51g3s0500hx.out 649,571 11-18-2019 03:40 8a79b4ee ea_ha325a2c51g3s0600hx.inp 3,824 11-18-2019 00:21 64a5eead ea_ha325a2c51g3s0600hx.out 649,551 11-18-2019 03:39 1dca5450 ea_ha325a2c51g3s0700hx.inp 3,824 11-18-2019 00:21 1178b234 ea_ha325a2c51g3s0700hx.out 649,685 11-18-2019 03:38 a994c283 ea_ha325a2c51g3s0800hx.inp 3,824 11-18-2019 00:21 a63cafa9 ea_ha325a2c51g3s0800hx.out 649,354 11-18-2019 03:37 671c68be ea_ha325a2c51g3s0900hx.inp 3,824 11-18-2019 00:21 aa3b92d5 ea_ha325a2c51g3s0900hx.out 649,944 11-18-2019 03:35 0674bf3e ea_ha325a2c51g3s1000hx.inp 3,828 11-18-2019 00:22 6002abbf ea_ha325a2c51g3s1000hx.out 650,873 11-18-2019 03:36 595a2860 ea_ha325a2c51g3s1100hx.inp 3,828 11-18-2019 00:22 2d0d91cc ea_ha325a2c51g3s1100hx.out 651,137 11-18-2019 03:35 7cc3db41 ea_ha325a2c51g3s1200hx.inp 3,828 11-18-2019 00:22 a7dd1cab ea_ha325a2c51g3s1200hx.out 649,558 11-18-2019 03:37 6f6746af ea_ha325a2c51g3s1300hx.inp 3,828 11-18-2019 00:22 7812f305 ea_ha325a2c51g3s1300hx.out 649,523 11-18-2019 03:37 30b433bc ea_ha325a2c51g3s1400hx.inp 3,828 11-18-2019 00:22 2688d17e ea_ha325a2c51g3s1400hx.out 649,896 11-18-2019 03:39 7a711c90 ea_ha325a2c51g3s1500hx.inp 3,828 11-18-2019 00:22 4e6ec14b ea_ha325a2c51g3s1500hx.out 649,924 11-18-2019 03:40 9e00bd91
\\v1.2\\ea\\hs245\\ (66) 20,731,728 11-20-2019 09:22 ea_hs245a2c51g1s0500hx.inp 3,911 11-18-2019 14:38 e088513b ea_hs245a2c51g1s0500hx.out 504,789 11-19-2019 18:16 93d8b7ed ea_hs245a2c51g1s0600hx.inp 3,912 11-18-2019 14:38 df3be7c0 ea_hs245a2c51g1s0600hx.out 504,227 11-19-2019 18:13 aa6825b3 ea_hs245a2c51g1s0700hx.inp 3,912 11-18-2019 14:38 0a7edcb2 ea_hs245a2c51g1s0700hx.out 503,312 11-19-2019 18:13 e6bdd0de ea_hs245a2c51g1s0800hx.inp 3,912 11-18-2019 14:38 7720c48f ea_hs245a2c51g1s0800hx.out 650,839 11-19-2019 18:17 e736dddf ea_hs245a2c51g1s0900hx.inp 3,912 11-18-2019 14:38 5a5cee7d ea_hs245a2c51g1s0900hx.out 652,219 11-19-2019 18:16 6799824e ea_hs245a2c51g1s1000hx.inp 3,916 11-18-2019 14:38 5c747bcf ea_hs245a2c51g1s1000hx.out 650,994 11-19-2019 18:15 2722f019 ea_hs245a2c51g1s1100hx.inp 3,916 11-18-2019 14:38 9ef3389c ea_hs245a2c51g1s1100hx.out 650,819 11-19-2019 18:13 455c7fd6 ea_hs245a2c51g1s1200hx.inp 3,916 11-18-2019 14:38 85895fec ea_hs245a2c51g1s1200hx.out 650,396 11-19-2019 18:19 f9157736 ea_hs245a2c51g1s1300hx.inp 3,916 11-18-2019 14:39 0bb292a4 ea_hs245a2c51g1s1300hx.out 651,242 11-19-2019 18:19 fdd598d4 ea_hs245a2c51g1s1400hx.inp 3,916 11-18-2019 14:39 7ddac704 ea_hs245a2c51g1s1400hx.out 651,242 11-19-2019 18:19 919349ae ea_hs245a2c51g1s1500hx.inp 3,916 11-18-2019 14:39 0a2f3bad ea_hs245a2c51g1s1500hx.out 650,965 11-19-2019 18:23 00ee4b6a ea_hs245a2c51g2s0500hx.inp 3,909 11-18-2019 14:39 2e7e0caa ea_hs245a2c51g2s0500hx.out 651,151 11-19-2019 19:23 e362c21b ea_hs245a2c51g2s0600hx.inp 3,910 11-18-2019 14:39 952871b9 ea_hs245a2c51g2s0600hx.out 650,885 11-19-2019 19:10 2d80ca5b ea_hs245a2c51g2s0700hx.inp 3,910 11-18-2019 14:39 ec9aad49 ea_hs245a2c51g2s0700hx.out 651,125 11-19-2019 19:08 ac5ca60c ea_hs245a2c51g2s0800hx.inp 3,910 11-18-2019 14:39 cb2e3109 ea_hs245a2c51g2s0800hx.out 650,678 11-19-2019 19:05 a8ea7bdd ea_hs245a2c51g2s0900hx.inp 3,910 11-18-2019 14:39 0fd7d4cf ea_hs245a2c51g2s0900hx.out 651,604 11-19-2019 19:03 4e7568b4 ea_hs245a2c51g2s1000hx.inp 3,914 11-18-2019 14:39 7b366f79 ea_hs245a2c51g2s1000hx.out 651,555 11-19-2019 19:15 1b6cce44 ea_hs245a2c51g2s1100hx.inp 3,914 11-18-2019 14:39 b2c74796 ea_hs245a2c51g2s1100hx.out 650,821 11-19-2019 19:02 c6787943 ea_hs245a2c51g2s1200hx.inp 3,914 11-18-2019 14:39 a7628b4c ea_hs245a2c51g2s1200hx.out 651,375 11-19-2019 19:09 a489d757 ea_hs245a2c51g2s1300hx.inp 3,914 11-18-2019 14:40 f0b7358a ea_hs245a2c51g2s1300hx.out 650,500 11-19-2019 19:10 d4ff5100 ea_hs245a2c51g2s1400hx.inp 3,914 11-18-2019 14:40 cfd70da8 ea_hs245a2c51g2s1400hx.out 651,160 11-19-2019 19:14 9a170df9 ea_hs245a2c51g2s1500hx.inp 3,914 11-18-2019 14:40 acf89a35 ea_hs245a2c51g2s1500hx.out 650,342 11-19-2019 18:51 680499b6 ea_hs245a2c51g3s0500hx.inp 3,906 11-18-2019 14:40 56bfd270 ea_hs245a2c51g3s0500hx.out 503,844 11-19-2019 18:45 685b3912 ea_hs245a2c51g3s0600hx.inp 3,907 11-18-2019 14:40 dc801337 ea_hs245a2c51g3s0600hx.out 503,536 11-19-2019 18:44 48c6a2e8 ea_hs245a2c51g3s0700hx.inp 3,907 11-18-2019 14:40 c885c8b0 ea_hs245a2c51g3s0700hx.out 504,452 11-19-2019 18:42 b583e6bf ea_hs245a2c51g3s0800hx.inp 3,907 11-18-2019 14:40 cd52f7ba ea_hs245a2c51g3s0800hx.out 651,317 11-19-2019 18:40 bc3465d1 ea_hs245a2c51g3s0900hx.inp 3,907 11-18-2019 14:40 62e17f12 ea_hs245a2c51g3s0900hx.out 650,584 11-19-2019 18:55 b2083c08 ea_hs245a2c51g3s1000hx.inp 3,911 11-18-2019 14:40 a23db478 ea_hs245a2c51g3s1000hx.out 651,013 11-19-2019 18:34 bc277ece ea_hs245a2c51g3s1100hx.inp 3,911 11-18-2019 14:40 1f543e16
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
108 of 190 ea_hs245a2c51g3s1100hx.out 651,003 11-19-2019 18:51 3010c7a3 ea_hs245a2c51g3s1200hx.inp 3,911 11-18-2019 14:40 100d06e1 ea_hs245a2c51g3s1200hx.out 651,054 11-19-2019 19:03 08d1fac5 ea_hs245a2c51g3s1300hx.inp 3,911 11-18-2019 14:41 b0ae9f2f ea_hs245a2c51g3s1300hx.out 650,595 11-19-2019 19:07 bd761905 ea_hs245a2c51g3s1400hx.inp 3,911 11-18-2019 14:41 137e4245 ea_hs245a2c51g3s1400hx.out 652,159 11-19-2019 18:54 ccf56f94 ea_hs245a2c51g3s1500hx.inp 3,911 11-18-2019 14:41 293b1942 ea_hs245a2c51g3s1500hx.out 650,843 11-19-2019 18:56 8ad462b4
\\v1.2\\ea\\hs325\\ (66) 21,276,966 11-20-2019 09:22 ea_hs325a2c51g1s0500hx.inp 3,862 11-18-2019 12:50 b2daab72 ea_hs325a2c51g1s0500hx.out 503,264 11-19-2019 13:09 d5726c10 ea_hs325a2c51g1s0600hx.inp 3,862 11-18-2019 12:50 f32944d2 ea_hs325a2c51g1s0600hx.out 649,815 11-19-2019 13:08 952c2872 ea_hs325a2c51g1s0700hx.inp 3,862 11-18-2019 12:50 f12eb433 ea_hs325a2c51g1s0700hx.out 650,001 11-19-2019 13:10 5254d307 ea_hs325a2c51g1s0800hx.inp 3,862 11-18-2019 12:50 7a26f1e9 ea_hs325a2c51g1s0800hx.out 649,737 11-19-2019 13:06 b7468e84 ea_hs325a2c51g1s0900hx.inp 3,862 11-18-2019 12:50 ddfff895 ea_hs325a2c51g1s0900hx.out 649,211 11-19-2019 13:09 478b0ded ea_hs325a2c51g1s1000hx.inp 3,866 11-18-2019 12:51 641e2ee0 ea_hs325a2c51g1s1000hx.out 649,825 11-19-2019 13:14 2c34fd07 ea_hs325a2c51g1s1100hx.inp 3,866 11-18-2019 12:51 c5a78924 ea_hs325a2c51g1s1100hx.out 649,716 11-19-2019 13:27 0f5faf76 ea_hs325a2c51g1s1200hx.inp 3,866 11-18-2019 12:51 3c521472 ea_hs325a2c51g1s1200hx.out 649,336 11-19-2019 13:25 aabdbf6c ea_hs325a2c51g1s1300hx.inp 3,866 11-18-2019 12:51 1e2dd2ac ea_hs325a2c51g1s1300hx.out 650,012 11-19-2019 13:16 efcff6d8 ea_hs325a2c51g1s1400hx.inp 3,866 11-18-2019 12:51 8cf46564 ea_hs325a2c51g1s1400hx.out 650,276 11-19-2019 13:20 09cfd83f ea_hs325a2c51g1s1500hx.inp 3,866 11-18-2019 12:51 8068c6cb ea_hs325a2c51g1s1500hx.out 650,388 11-19-2019 13:11 6ee26f17 ea_hs325a2c51g2s0500hx.inp 3,860 11-18-2019 12:51 bb7b78f8 ea_hs325a2c51g2s0500hx.out 649,833 11-19-2019 14:21 c405c02a ea_hs325a2c51g2s0600hx.inp 3,860 11-18-2019 12:51 f4c7c292 ea_hs325a2c51g2s0600hx.out 650,490 11-19-2019 14:09 ad88717f ea_hs325a2c51g2s0700hx.inp 3,860 11-18-2019 12:51 0a00ba06 ea_hs325a2c51g2s0700hx.out 649,856 11-19-2019 14:04 7c3bb134 ea_hs325a2c51g2s0800hx.inp 3,860 11-18-2019 12:51 1cc65d58 ea_hs325a2c51g2s0800hx.out 649,719 11-19-2019 14:10 956f4619 ea_hs325a2c51g2s0900hx.inp 3,860 11-18-2019 12:51 4a7528a8 ea_hs325a2c51g2s0900hx.out 649,752 11-19-2019 14:12 2e8549cc ea_hs325a2c51g2s1000hx.inp 3,864 11-18-2019 12:52 50f74149 ea_hs325a2c51g2s1000hx.out 650,218 11-19-2019 13:54 86a58298 ea_hs325a2c51g2s1100hx.inp 3,864 11-18-2019 12:52 957dbf08 ea_hs325a2c51g2s1100hx.out 649,335 11-19-2019 14:01 4daef556 ea_hs325a2c51g2s1200hx.inp 3,864 11-18-2019 12:52 bd2972a7 ea_hs325a2c51g2s1200hx.out 649,051 11-19-2019 14:05 9a8967d2 ea_hs325a2c51g2s1300hx.inp 3,864 11-18-2019 12:52 5dcc23bc ea_hs325a2c51g2s1300hx.out 649,901 11-19-2019 13:55 822622f7 ea_hs325a2c51g2s1400hx.inp 3,864 11-18-2019 12:52 728e3554 ea_hs325a2c51g2s1400hx.out 649,469 11-19-2019 14:06 c546519f ea_hs325a2c51g2s1500hx.inp 3,864 11-18-2019 12:52 9a970b3b ea_hs325a2c51g2s1500hx.out 650,502 11-19-2019 14:25 e712429e ea_hs325a2c51g3s0500hx.inp 3,857 11-18-2019 12:52 cd090ca4 ea_hs325a2c51g3s0500hx.out 502,716 11-19-2019 13:43 0c66a550 ea_hs325a2c51g3s0600hx.inp 3,857 11-18-2019 12:52 864e6bbd ea_hs325a2c51g3s0600hx.out 649,198 11-19-2019 13:39 23d2691b ea_hs325a2c51g3s0700hx.inp 3,857 11-18-2019 12:52 7311633d ea_hs325a2c51g3s0700hx.out 650,041 11-19-2019 13:42 e38d7b05 ea_hs325a2c51g3s0800hx.inp 3,857 11-18-2019 12:52 1e6e1d58 ea_hs325a2c51g3s0800hx.out 649,529 11-19-2019 13:42 d87d9605 ea_hs325a2c51g3s0900hx.inp 3,857 11-18-2019 12:52 10b7a224 ea_hs325a2c51g3s0900hx.out 649,508 11-19-2019 13:43 c9c1ae70 ea_hs325a2c51g3s1000hx.inp 3,861 11-18-2019 12:53 547c4e9a ea_hs325a2c51g3s1000hx.out 649,656 11-19-2019 13:43 52cd71a4 ea_hs325a2c51g3s1100hx.inp 3,861 11-18-2019 12:53 20fbe478 ea_hs325a2c51g3s1100hx.out 650,057 11-19-2019 13:47 1e1b37aa ea_hs325a2c51g3s1200hx.inp 3,861 11-18-2019 12:53 687482cc ea_hs325a2c51g3s1200hx.out 650,152 11-19-2019 13:44 c632cacf ea_hs325a2c51g3s1300hx.inp 3,861 11-18-2019 12:53 0c146d1e ea_hs325a2c51g3s1300hx.out 649,317 11-19-2019 13:43 1215556e ea_hs325a2c51g3s1400hx.inp 3,861 11-18-2019 12:53 78fd2f6c ea_hs325a2c51g3s1400hx.out 649,321 11-19-2019 13:51 5413d360 ea_hs325a2c51g3s1500hx.inp 3,861 11-18-2019 12:53 72c1ffd0 ea_hs325a2c51g3s1500hx.out 650,323 11-19-2019 13:51 a5595de0
\\v1.2\\ea\\na245\\ (66) 20,435,344 11-20-2019 09:22
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
109 of 190 ea_na245a2c51g1s0500hx.inp 3,910 11-18-2019 11:27 49b1757d ea_na245a2c51g1s0500hx.out 650,617 11-19-2019 05:58 a3cfd3d4 ea_na245a2c51g1s0600hx.inp 3,911 11-18-2019 11:28 01853d91 ea_na245a2c51g1s0600hx.out 649,580 11-19-2019 06:07 54512fde ea_na245a2c51g1s0700hx.inp 3,911 11-18-2019 11:28 3698daed ea_na245a2c51g1s0700hx.out 650,895 11-19-2019 06:07 7d95f3b0 ea_na245a2c51g1s0800hx.inp 3,911 11-18-2019 11:28 393ebbfc ea_na245a2c51g1s0800hx.out 651,186 11-19-2019 06:06 0ff8d96f ea_na245a2c51g1s0900hx.inp 3,911 11-18-2019 11:28 e3e62ca5 ea_na245a2c51g1s0900hx.out 650,610 11-19-2019 06:09 7a13b25b ea_na245a2c51g1s1000hx.inp 3,915 11-18-2019 11:28 c71f9bb8 ea_na245a2c51g1s1000hx.out 650,889 11-19-2019 06:04 497940ec ea_na245a2c51g1s1100hx.inp 3,915 11-18-2019 11:28 c2db4f2d ea_na245a2c51g1s1100hx.out 651,633 11-19-2019 06:10 04a037ca ea_na245a2c51g1s1200hx.inp 3,915 11-18-2019 11:28 2601dd81 ea_na245a2c51g1s1200hx.out 650,306 11-19-2019 06:06 5d2e48f9 ea_na245a2c51g1s1300hx.inp 3,915 11-18-2019 11:28 2b61b1ab ea_na245a2c51g1s1300hx.out 649,781 11-19-2019 06:10 ab64c2c3 ea_na245a2c51g1s1400hx.inp 3,915 11-18-2019 11:28 98833d73 ea_na245a2c51g1s1400hx.out 651,385 11-19-2019 06:18 a0eb986b ea_na245a2c51g1s1500hx.inp 3,915 11-18-2019 11:28 bde94e38 ea_na245a2c51g1s1500hx.out 650,132 11-19-2019 06:18 4c9e42f8 ea_na245a2c51g2s0500hx.inp 3,908 11-18-2019 11:28 478feaf3 ea_na245a2c51g2s0500hx.out 504,423 11-19-2019 07:01 d9369613 ea_na245a2c51g2s0600hx.inp 3,909 11-18-2019 11:28 9a12d89d ea_na245a2c51g2s0600hx.out 504,329 11-19-2019 07:01 0ed91c51 ea_na245a2c51g2s0700hx.inp 3,909 11-18-2019 11:29 b239b0a7 ea_na245a2c51g2s0700hx.out 505,339 11-19-2019 06:56 316423f8 ea_na245a2c51g2s0800hx.inp 3,909 11-18-2019 11:29 e2d531e1 ea_na245a2c51g2s0800hx.out 504,217 11-19-2019 07:00 a4273bcc ea_na245a2c51g2s0900hx.inp 3,909 11-18-2019 11:29 1045dde2 ea_na245a2c51g2s0900hx.out 504,479 11-19-2019 07:05 98e4a1fe ea_na245a2c51g2s1000hx.inp 3,913 11-18-2019 11:29 5e9bf4eb ea_na245a2c51g2s1000hx.out 503,966 11-19-2019 07:02 06ee4995 ea_na245a2c51g2s1100hx.inp 3,913 11-18-2019 11:29 92834669 ea_na245a2c51g2s1100hx.out 504,878 11-19-2019 07:08 9ed127e6 ea_na245a2c51g2s1200hx.inp 3,913 11-18-2019 11:29 866bf9d1 ea_na245a2c51g2s1200hx.out 504,136 11-19-2019 07:04 6f2b0bac ea_na245a2c51g2s1300hx.inp 3,913 11-18-2019 11:29 d2573985 ea_na245a2c51g2s1300hx.out 651,341 11-19-2019 07:02 5924c97a ea_na245a2c51g2s1400hx.inp 3,913 11-18-2019 11:29 63388be8 ea_na245a2c51g2s1400hx.out 651,521 11-19-2019 06:49 9e89297f ea_na245a2c51g2s1500hx.inp 3,913 11-18-2019 11:29 1ff54719 ea_na245a2c51g2s1500hx.out 650,827 11-19-2019 06:48 69c5fa69 ea_na245a2c51g3s0500hx.inp 3,905 11-18-2019 11:29 d76392d1 ea_na245a2c51g3s0500hx.out 650,580 11-19-2019 06:50 92b40cd0 ea_na245a2c51g3s0600hx.inp 3,906 11-18-2019 11:29 b71e6e6e ea_na245a2c51g3s0600hx.out 649,753 11-19-2019 06:52 8c0734b5 ea_na245a2c51g3s0700hx.inp 3,906 11-18-2019 11:30 675579be ea_na245a2c51g3s0700hx.out 651,975 11-19-2019 06:31 140859d0 ea_na245a2c51g3s0800hx.inp 3,906 11-18-2019 11:30 4bbbc822 ea_na245a2c51g3s0800hx.out 650,825 11-19-2019 06:48 8e4335a7 ea_na245a2c51g3s0900hx.inp 3,906 11-18-2019 11:30 a55b8e06 ea_na245a2c51g3s0900hx.out 650,584 11-19-2019 06:52 f0e5de65 ea_na245a2c51g3s1000hx.inp 3,910 11-18-2019 11:30 39661bbd ea_na245a2c51g3s1000hx.out 650,949 11-19-2019 06:51 5aff6ac5 ea_na245a2c51g3s1100hx.inp 3,910 11-18-2019 11:30 18cc4749 ea_na245a2c51g3s1100hx.out 650,889 11-19-2019 06:51 71915376 ea_na245a2c51g3s1200hx.inp 3,910 11-18-2019 11:30 239cd93c ea_na245a2c51g3s1200hx.out 651,066 11-19-2019 06:52 90e00667 ea_na245a2c51g3s1300hx.inp 3,910 11-18-2019 11:30 2aa305f7 ea_na245a2c51g3s1300hx.out 651,064 11-19-2019 06:55 90a2dad3 ea_na245a2c51g3s1400hx.inp 3,910 11-18-2019 11:30 cce9842a ea_na245a2c51g3s1400hx.out 650,915 11-19-2019 06:58 cb22e79c ea_na245a2c51g3s1500hx.inp 3,910 11-18-2019 11:30 196e867f ea_na245a2c51g3s1500hx.out 651,219 11-19-2019 06:59 1b902912
\\v1.2\\ea\\na325\\ (66) 20,982,084 11-20-2019 09:22 ea_na325a2c51g1s0500hx.inp 3,861 11-18-2019 10:25 9a360d71 ea_na325a2c51g1s0500hx.out 649,715 11-18-2019 21:52 99c3dd45 ea_na325a2c51g1s0600hx.inp 3,861 11-18-2019 10:25 248a3a58 ea_na325a2c51g1s0600hx.out 649,563 11-18-2019 21:50 bbfdece1 ea_na325a2c51g1s0700hx.inp 3,861 11-18-2019 10:25 a564bdca ea_na325a2c51g1s0700hx.out 649,842 11-18-2019 21:50 69d62620 ea_na325a2c51g1s0800hx.inp 3,861 11-18-2019 10:25 f7dd6d5b ea_na325a2c51g1s0800hx.out 649,767 11-18-2019 21:52 13c14e1e ea_na325a2c51g1s0900hx.inp 3,861 11-18-2019 10:25 6493f276 ea_na325a2c51g1s0900hx.out 649,247 11-18-2019 22:01 f675b3e5 ea_na325a2c51g1s1000hx.inp 3,865 11-18-2019 10:25 2b8149c8 ea_na325a2c51g1s1000hx.out 649,686 11-18-2019 21:57 8dc3490d
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
110 of 190 ea_na325a2c51g1s1100hx.inp 3,865 11-18-2019 10:25 6bc2ecf3 ea_na325a2c51g1s1100hx.out 650,580 11-18-2019 21:54 562abd9d ea_na325a2c51g1s1200hx.inp 3,865 11-18-2019 10:25 1f9ade9d ea_na325a2c51g1s1200hx.out 649,406 11-18-2019 22:05 a4a7034e ea_na325a2c51g1s1300hx.inp 3,865 11-18-2019 10:25 b54a7a76 ea_na325a2c51g1s1300hx.out 650,162 11-18-2019 21:59 b51e02b9 ea_na325a2c51g1s1400hx.inp 3,865 11-18-2019 10:25 0652c58c ea_na325a2c51g1s1400hx.out 649,771 11-18-2019 22:00 5c2bd9f8 ea_na325a2c51g1s1500hx.inp 3,865 11-18-2019 10:25 3b352e1e ea_na325a2c51g1s1500hx.out 649,854 11-18-2019 22:05 05238d3b ea_na325a2c51g2s0500hx.inp 3,859 11-18-2019 10:26 98cf527d ea_na325a2c51g2s0500hx.out 503,367 11-18-2019 22:55 822a19ea ea_na325a2c51g2s0600hx.inp 3,859 11-18-2019 10:26 f7ff62a0 ea_na325a2c51g2s0600hx.out 504,379 11-18-2019 22:59 962b5e16 ea_na325a2c51g2s0700hx.inp 3,859 11-18-2019 10:26 2a2532e6 ea_na325a2c51g2s0700hx.out 502,564 11-18-2019 22:50 b9dfe5b6 ea_na325a2c51g2s0800hx.inp 3,859 11-18-2019 10:26 32bb245f ea_na325a2c51g2s0800hx.out 503,208 11-18-2019 22:53 d3e13602 ea_na325a2c51g2s0900hx.inp 3,859 11-18-2019 10:26 73ceed70 ea_na325a2c51g2s0900hx.out 649,679 11-18-2019 22:56 14d461e9 ea_na325a2c51g2s1000hx.inp 3,863 11-18-2019 10:26 27ce0a23 ea_na325a2c51g2s1000hx.out 650,270 11-18-2019 22:56 ec6c47e5 ea_na325a2c51g2s1100hx.inp 3,863 11-18-2019 10:26 924b8af6 ea_na325a2c51g2s1100hx.out 650,001 11-18-2019 22:59 e6fbc2ee ea_na325a2c51g2s1200hx.inp 3,863 11-18-2019 10:26 24a597d9 ea_na325a2c51g2s1200hx.out 649,488 11-18-2019 22:58 ebd25d89 ea_na325a2c51g2s1300hx.inp 3,863 11-18-2019 10:26 3b8ca571 ea_na325a2c51g2s1300hx.out 649,585 11-18-2019 23:15 a82c4620 ea_na325a2c51g2s1400hx.inp 3,863 11-18-2019 10:26 bf8eb443 ea_na325a2c51g2s1400hx.out 649,906 11-18-2019 23:10 bce4c603 ea_na325a2c51g2s1500hx.inp 3,863 11-18-2019 10:26 3e32e605 ea_na325a2c51g2s1500hx.out 649,825 11-18-2019 23:10 8b419e3f ea_na325a2c51g3s0500hx.inp 3,856 11-18-2019 10:26 f9bf97c5 ea_na325a2c51g3s0500hx.out 649,780 11-18-2019 22:41 331ce7d3 ea_na325a2c51g3s0600hx.inp 3,856 11-18-2019 10:27 8b2a9574 ea_na325a2c51g3s0600hx.out 649,339 11-18-2019 22:47 e3319b01 ea_na325a2c51g3s0700hx.inp 3,856 11-18-2019 10:27 4464c6fe ea_na325a2c51g3s0700hx.out 649,339 11-18-2019 22:49 1660c8eb ea_na325a2c51g3s0800hx.inp 3,856 11-18-2019 10:27 4e6eec5f ea_na325a2c51g3s0800hx.out 649,578 11-18-2019 22:47 4d32b725 ea_na325a2c51g3s0900hx.inp 3,856 11-18-2019 10:27 313ae797 ea_na325a2c51g3s0900hx.out 649,347 11-18-2019 22:42 8c90d9a8 ea_na325a2c51g3s1000hx.inp 3,860 11-18-2019 10:27 8591dee2 ea_na325a2c51g3s1000hx.out 649,632 11-18-2019 22:50 c4f639fa ea_na325a2c51g3s1100hx.inp 3,860 11-18-2019 10:27 f2287821 ea_na325a2c51g3s1100hx.out 649,316 11-18-2019 22:52 4cc88d27 ea_na325a2c51g3s1200hx.inp 3,860 11-18-2019 10:27 103eb2e5 ea_na325a2c51g3s1200hx.out 648,983 11-18-2019 22:53 09d0f51e ea_na325a2c51g3s1300hx.inp 3,860 11-18-2019 10:27 799bb4b6 ea_na325a2c51g3s1300hx.out 650,881 11-18-2019 22:52 3cca5d9f ea_na325a2c51g3s1400hx.inp 3,860 11-18-2019 10:27 bd69d301 ea_na325a2c51g3s1400hx.out 649,402 11-18-2019 22:53 97918682 ea_na325a2c51g3s1500hx.inp 3,860 11-18-2019 10:27 1337ed63 ea_na325a2c51g3s1500hx.out 649,214 11-18-2019 22:57 a302697c
\\v1.2\\ea\\ns245\\ (66) 20,583,332 11-20-2019 09:22 ea_ns245a2c51g1s0500hx.inp 3,911 11-18-2019 17:10 349bdf4b ea_ns245a2c51g1s0500hx.out 504,136 11-20-2019 04:53 399d1b86 ea_ns245a2c51g1s0600hx.inp 3,912 11-18-2019 17:10 bd0388dd ea_ns245a2c51g1s0600hx.out 504,722 11-20-2019 04:49 42d8dfd7 ea_ns245a2c51g1s0700hx.inp 3,912 11-18-2019 17:10 6846b3af ea_ns245a2c51g1s0700hx.out 650,403 11-20-2019 04:59 66581c21 ea_ns245a2c51g1s0800hx.inp 3,912 11-18-2019 17:10 1518ab92 ea_ns245a2c51g1s0800hx.out 651,143 11-20-2019 04:53 19bcfff9 ea_ns245a2c51g1s0900hx.inp 3,912 11-18-2019 17:10 38648160 ea_ns245a2c51g1s0900hx.out 650,851 11-20-2019 04:52 15a41f0b ea_ns245a2c51g1s1000hx.inp 3,916 11-18-2019 17:10 0c137efd ea_ns245a2c51g1s1000hx.out 651,875 11-20-2019 05:02 5649c3e1 ea_ns245a2c51g1s1100hx.inp 3,916 11-18-2019 17:10 ce943dae ea_ns245a2c51g1s1100hx.out 651,297 11-20-2019 04:56 5112a9da ea_ns245a2c51g1s1200hx.inp 3,916 11-18-2019 17:10 d5ee5ade ea_ns245a2c51g1s1200hx.out 650,984 11-20-2019 04:57 aeb13ac3 ea_ns245a2c51g1s1300hx.inp 3,916 11-18-2019 17:10 5bd59796 ea_ns245a2c51g1s1300hx.out 650,969 11-20-2019 05:09 1758d920 ea_ns245a2c51g1s1400hx.inp 3,916 11-18-2019 17:10 2dbdc236 ea_ns245a2c51g1s1400hx.out 650,856 11-20-2019 05:08 18262e05 ea_ns245a2c51g1s1500hx.inp 3,916 11-18-2019 17:11 5a483e9f ea_ns245a2c51g1s1500hx.out 651,164 11-20-2019 05:10 33287a78 ea_ns245a2c51g2s0500hx.inp 3,909 11-18-2019 17:11 c990b585 ea_ns245a2c51g2s0500hx.out 649,602 11-20-2019 05:51 949a5e81
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
111 of 190 ea_ns245a2c51g2s0600hx.inp 3,910 11-18-2019 17:11 0cf7aff6 ea_ns245a2c51g2s0600hx.out 651,129 11-20-2019 06:00 bf506561 ea_ns245a2c51g2s0700hx.inp 3,910 11-18-2019 17:11 75457306 ea_ns245a2c51g2s0700hx.out 650,603 11-20-2019 05:24 5137716c ea_ns245a2c51g2s0800hx.inp 3,910 11-18-2019 17:11 52f1ef46 ea_ns245a2c51g2s0800hx.out 650,980 11-20-2019 05:43 f9296ebc ea_ns245a2c51g2s0900hx.inp 3,910 11-18-2019 17:11 96080a80 ea_ns245a2c51g2s0900hx.out 651,018 11-20-2019 05:52 34d26159 ea_ns245a2c51g2s1000hx.inp 3,914 11-18-2019 17:11 ec864fa7 ea_ns245a2c51g2s1000hx.out 650,741 11-20-2019 05:48 4143d894 ea_ns245a2c51g2s1100hx.inp 3,914 11-18-2019 17:11 25776748 ea_ns245a2c51g2s1100hx.out 650,464 11-20-2019 05:38 d9f78b76 ea_ns245a2c51g2s1200hx.inp 3,914 11-18-2019 17:11 30d2ab92 ea_ns245a2c51g2s1200hx.out 650,644 11-20-2019 05:34 baaf2811 ea_ns245a2c51g2s1300hx.inp 3,914 11-18-2019 17:11 67071554 ea_ns245a2c51g2s1300hx.out 650,752 11-20-2019 05:56 73cbed31 ea_ns245a2c51g2s1400hx.inp 3,914 11-18-2019 17:11 58672d76 ea_ns245a2c51g2s1400hx.out 650,783 11-20-2019 05:55 6fcc855f ea_ns245a2c51g2s1500hx.inp 3,914 11-18-2019 17:12 3b48baeb ea_ns245a2c51g2s1500hx.out 651,104 11-20-2019 05:43 a71adf9f ea_ns245a2c51g3s0500hx.inp 3,906 11-18-2019 17:12 444a58ca ea_ns245a2c51g3s0500hx.out 504,369 11-20-2019 05:24 80366488 ea_ns245a2c51g3s0600hx.inp 3,907 11-18-2019 17:12 c5cfb180 ea_ns245a2c51g3s0600hx.out 504,803 11-20-2019 05:26 51a841ab ea_ns245a2c51g3s0700hx.inp 3,907 11-18-2019 17:12 d1ca6a07 ea_ns245a2c51g3s0700hx.out 504,551 11-20-2019 05:27 d6f30879 ea_ns245a2c51g3s0800hx.inp 3,907 11-18-2019 17:12 d41d550d ea_ns245a2c51g3s0800hx.out 505,523 11-20-2019 05:25 323c3e1d ea_ns245a2c51g3s0900hx.inp 3,907 11-18-2019 17:12 7baedda5 ea_ns245a2c51g3s0900hx.out 504,435 11-20-2019 05:27 eb349d05 ea_ns245a2c51g3s1000hx.inp 3,911 11-18-2019 17:12 a1d35b40 ea_ns245a2c51g3s1000hx.out 651,085 11-20-2019 05:23 29c949f7 ea_ns245a2c51g3s1100hx.inp 3,911 11-18-2019 17:12 1cbad12e ea_ns245a2c51g3s1100hx.out 649,583 11-20-2019 05:27 815e39f8 ea_ns245a2c51g3s1200hx.inp 3,911 11-18-2019 17:12 13e3e9d9 ea_ns245a2c51g3s1200hx.out 651,244 11-20-2019 05:27 4a4be3e4 ea_ns245a2c51g3s1300hx.inp 3,911 11-18-2019 17:12 b3407017 ea_ns245a2c51g3s1300hx.out 650,747 11-20-2019 05:41 0e45f706 ea_ns245a2c51g3s1400hx.inp 3,911 11-18-2019 17:12 1090ad7d ea_ns245a2c51g3s1400hx.out 650,736 11-20-2019 05:28 2bf772c2 ea_ns245a2c51g3s1500hx.inp 3,911 11-18-2019 17:13 2ad5f67a ea_ns245a2c51g3s1500hx.out 650,948 11-20-2019 05:48 29211d09
\\v1.2\\ea\\ns325\\ (66) 21,281,498 11-20-2019 09:22 ea_ns325a2c51g1s0500hx.inp 3,862 11-18-2019 16:05 82173954 ea_ns325a2c51g1s0500hx.out 650,852 11-19-2019 23:45 2e99b3c9 ea_ns325a2c51g1s0600hx.inp 3,862 11-18-2019 16:05 c3e4d6f4 ea_ns325a2c51g1s0600hx.out 648,854 11-19-2019 23:38 a7e3b7fe ea_ns325a2c51g1s0700hx.inp 3,862 11-18-2019 16:05 c1e32615 ea_ns325a2c51g1s0700hx.out 650,063 11-19-2019 23:43 7115faff ea_ns325a2c51g1s0800hx.inp 3,862 11-18-2019 16:05 4aeb63cf ea_ns325a2c51g1s0800hx.out 651,050 11-19-2019 23:41 31019871 ea_ns325a2c51g1s0900hx.inp 3,862 11-18-2019 16:05 ed326ab3 ea_ns325a2c51g1s0900hx.out 649,646 11-19-2019 23:38 157ff5a5 ea_ns325a2c51g1s1000hx.inp 3,866 11-18-2019 16:06 e5675cce ea_ns325a2c51g1s1000hx.out 649,637 11-19-2019 23:38 66a44cb3 ea_ns325a2c51g1s1100hx.inp 3,866 11-18-2019 16:06 44defb0a ea_ns325a2c51g1s1100hx.out 649,565 11-19-2019 23:54 698e4ebd ea_ns325a2c51g1s1200hx.inp 3,866 11-18-2019 16:06 bd2b665c ea_ns325a2c51g1s1200hx.out 649,385 11-19-2019 23:41 78e15535 ea_ns325a2c51g1s1300hx.inp 3,866 11-18-2019 16:06 9f54a082 ea_ns325a2c51g1s1300hx.out 649,804 11-19-2019 23:54 9d341637 ea_ns325a2c51g1s1400hx.inp 3,866 11-18-2019 16:06 0d8d174a ea_ns325a2c51g1s1400hx.out 650,682 11-20-2019 00:02 29998610 ea_ns325a2c51g1s1500hx.inp 3,866 11-18-2019 16:06 0111b4e5 ea_ns325a2c51g1s1500hx.out 649,815 11-19-2019 23:42 309353e6 ea_ns325a2c51g2s0500hx.inp 3,860 11-18-2019 16:06 efdeba32 ea_ns325a2c51g2s0500hx.out 649,162 11-20-2019 00:52 ad2033fd ea_ns325a2c51g2s0600hx.inp 3,860 11-18-2019 16:06 a0620058 ea_ns325a2c51g2s0600hx.out 649,443 11-20-2019 00:45 c9d377a3 ea_ns325a2c51g2s0700hx.inp 3,860 11-18-2019 16:06 5ea578cc ea_ns325a2c51g2s0700hx.out 649,332 11-20-2019 00:37 43b1cfa7 ea_ns325a2c51g2s0800hx.inp 3,860 11-18-2019 16:06 48639f92 ea_ns325a2c51g2s0800hx.out 650,251 11-20-2019 00:50 44c56437 ea_ns325a2c51g2s0900hx.inp 3,860 11-18-2019 16:06 1ed0ea62 ea_ns325a2c51g2s0900hx.out 650,051 11-20-2019 00:45 dcab0007 ea_ns325a2c51g2s1000hx.inp 3,864 11-18-2019 16:07 dd1faeb0 ea_ns325a2c51g2s1000hx.out 650,151 11-20-2019 00:31 e0b1f56c ea_ns325a2c51g2s1100hx.inp 3,864 11-18-2019 16:07 189550f1 ea_ns325a2c51g2s1100hx.out 650,468 11-20-2019 00:33 8c352d24
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
112 of 190 ea_ns325a2c51g2s1200hx.inp 3,864 11-18-2019 16:07 30c19d5e ea_ns325a2c51g2s1200hx.out 649,730 11-20-2019 00:52 f711dd2b ea_ns325a2c51g2s1300hx.inp 3,864 11-18-2019 16:07 d024cc45 ea_ns325a2c51g2s1300hx.out 651,062 11-20-2019 00:34 c664bb6e ea_ns325a2c51g2s1400hx.inp 3,864 11-18-2019 16:07 ff66daad ea_ns325a2c51g2s1400hx.out 649,822 11-20-2019 00:35 8834f1f3 ea_ns325a2c51g2s1500hx.inp 3,864 11-18-2019 16:07 177fe4c2 ea_ns325a2c51g2s1500hx.out 650,108 11-20-2019 00:54 e1e04336 ea_ns325a2c51g3s0500hx.inp 3,857 11-18-2019 16:07 4d6b759c ea_ns325a2c51g3s0500hx.out 503,334 11-20-2019 00:10 e57e3d2e ea_ns325a2c51g3s0600hx.inp 3,857 11-18-2019 16:07 062c1285 ea_ns325a2c51g3s0600hx.out 503,517 11-20-2019 00:20 5b1dbf9e ea_ns325a2c51g3s0700hx.inp 3,857 11-18-2019 16:07 f3731a05 ea_ns325a2c51g3s0700hx.out 649,560 11-20-2019 00:14 6b7cb7f4 ea_ns325a2c51g3s0800hx.inp 3,857 11-18-2019 16:07 9e0c6460 ea_ns325a2c51g3s0800hx.out 649,748 11-20-2019 00:10 99773c0b ea_ns325a2c51g3s0900hx.inp 3,857 11-18-2019 16:07 90d5db1c ea_ns325a2c51g3s0900hx.out 651,440 11-20-2019 00:05 772521ff ea_ns325a2c51g3s1000hx.inp 3,861 11-18-2019 16:08 95dfa1ba ea_ns325a2c51g3s1000hx.out 649,584 11-20-2019 00:01 2570e9db ea_ns325a2c51g3s1100hx.inp 3,861 11-18-2019 16:08 e1580b58 ea_ns325a2c51g3s1100hx.out 649,648 11-20-2019 00:24 ed08ec21 ea_ns325a2c51g3s1200hx.inp 3,861 11-18-2019 16:08 a9d76dec ea_ns325a2c51g3s1200hx.out 649,329 11-20-2019 00:03 8f0ede9f ea_ns325a2c51g3s1300hx.inp 3,861 11-18-2019 16:08 cdb7823e ea_ns325a2c51g3s1300hx.out 649,890 11-20-2019 00:14 176acb19 ea_ns325a2c51g3s1400hx.inp 3,861 11-18-2019 16:08 b95ec04c ea_ns325a2c51g3s1400hx.out 649,833 11-20-2019 00:17 4b39faa0 ea_ns325a2c51g3s1500hx.inp 3,861 11-18-2019 16:08 b36210f0 ea_ns325a2c51g3s1500hx.out 649,241 11-20-2019 00:19 56864d87
\\v1.2\\eb\\ (0) 45,375,081 11-18-2019 17:13
\\v1.2\\eb\\ha245\\ (22) 5,590,788 11-18-2019 20:33 eb_ha245b2c51g0s0500hx.inp 3,953 11-18-2019 02:16 2c5317c8 eb_ha245b2c51g0s0500hx.out 503,906 11-18-2019 15:22 88ba004e eb_ha245b2c51g0s0600hx.inp 3,954 11-18-2019 02:16 3d9d9ba5 eb_ha245b2c51g0s0600hx.out 504,816 11-18-2019 15:18 a337c529 eb_ha245b2c51g0s0700hx.inp 3,954 11-18-2019 02:16 cbebdbca eb_ha245b2c51g0s0700hx.out 504,277 11-18-2019 15:26 11533eb6 eb_ha245b2c51g0s0800hx.inp 3,954 11-18-2019 02:16 7f361e0b eb_ha245b2c51g0s0800hx.out 504,034 11-18-2019 15:31 91ba921e eb_ha245b2c51g0s0900hx.inp 3,954 11-18-2019 02:16 5680a3c6 eb_ha245b2c51g0s0900hx.out 504,726 11-18-2019 15:24 371aee86 eb_ha245b2c51g0s1000hx.inp 3,958 11-18-2019 02:16 34047f20 eb_ha245b2c51g0s1000hx.out 503,823 11-18-2019 15:41 e703eafd eb_ha245b2c51g0s1100hx.inp 3,958 11-18-2019 02:16 5f9c51cf eb_ha245b2c51g0s1100hx.out 502,913 11-18-2019 15:41 71b1894a eb_ha245b2c51g0s1200hx.inp 3,958 11-18-2019 02:16 7d785d10 eb_ha245b2c51g0s1200hx.out 504,822 11-18-2019 15:47 42a1a713 eb_ha245b2c51g0s1300hx.inp 3,958 11-18-2019 02:16 5e32ef21 eb_ha245b2c51g0s1300hx.out 504,838 11-18-2019 15:44 339e2c15 eb_ha245b2c51g0s1400hx.inp 3,958 11-18-2019 02:16 24c32d95 eb_ha245b2c51g0s1400hx.out 504,274 11-18-2019 15:49 4fc60b8a eb_ha245b2c51g0s1500hx.inp 3,958 11-18-2019 02:17 4cef9d75 eb_ha245b2c51g0s1500hx.out 504,842 11-18-2019 15:43 c3fc5546
\\v1.2\\eb\\ha325\\ (22) 6,308,461 11-18-2019 20:33 eb_ha325b2c51g0s0500hx.inp 3,899 11-18-2019 00:22 f41d5093 eb_ha325b2c51g0s0500hx.out 501,623 11-18-2019 03:38 ea806bfd eb_ha325b2c51g0s0600hx.inp 3,899 11-18-2019 00:22 e34bf802 eb_ha325b2c51g0s0600hx.out 503,312 11-18-2019 03:41 700ca168 eb_ha325b2c51g0s0700hx.inp 3,899 11-18-2019 00:22 c5f5d311 eb_ha325b2c51g0s0700hx.out 503,159 11-18-2019 03:42 47ae57f5 eb_ha325b2c51g0s0800hx.inp 3,899 11-18-2019 00:22 9aad114e eb_ha325b2c51g0s0800hx.out 503,803 11-18-2019 03:39 99cee8cd eb_ha325b2c51g0s0900hx.inp 3,899 11-18-2019 00:22 0fae55f8 eb_ha325b2c51g0s0900hx.out 503,388 11-18-2019 03:35 4c9273fa eb_ha325b2c51g0s1000hx.inp 3,903 11-18-2019 00:22 56a82cd4 eb_ha325b2c51g0s1000hx.out 503,259 11-18-2019 03:43 2e3ca6d7 eb_ha325b2c51g0s1100hx.inp 3,903 11-18-2019 00:22 c6997acf eb_ha325b2c51g0s1100hx.out 649,247 11-18-2019 03:39 184cb506 eb_ha325b2c51g0s1200hx.inp 3,903 11-18-2019 00:23 a0466cc9 eb_ha325b2c51g0s1200hx.out 649,510 11-18-2019 03:40 e2c758e2 eb_ha325b2c51g0s1300hx.inp 3,903 11-18-2019 00:23 196cbdbe eb_ha325b2c51g0s1300hx.out 648,842 11-18-2019 03:41 775fbb86 eb_ha325b2c51g0s1400hx.inp 3,903 11-18-2019 00:23 4efac438 eb_ha325b2c51g0s1400hx.out 649,842 11-18-2019 03:42 37d31707
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
113 of 190 eb_ha325b2c51g0s1500hx.inp 3,903 11-18-2019 00:23 0bd23278 eb_ha325b2c51g0s1500hx.out 649,563 11-18-2019 03:42 366e4e97
\\v1.2\\eb\\hs245\\ (22) 5,586,266 11-20-2019 09:22 eb_hs245b2c51g0s0500hx.inp 3,981 11-18-2019 14:41 8cebddac eb_hs245b2c51g0s0500hx.out 504,552 11-19-2019 19:13 50da0662 eb_hs245b2c51g0s0600hx.inp 3,982 11-18-2019 14:41 1cef1b4d eb_hs245b2c51g0s0600hx.out 502,689 11-19-2019 19:14 6eca6e61 eb_hs245b2c51g0s0700hx.inp 3,982 11-18-2019 14:41 1fda736c eb_hs245b2c51g0s0700hx.out 503,586 11-19-2019 19:07 8124f7e6 eb_hs245b2c51g0s0800hx.inp 3,982 11-18-2019 14:41 187c8ea8 eb_hs245b2c51g0s0800hx.out 504,468 11-19-2019 19:02 4d6b226d eb_hs245b2c51g0s0900hx.inp 3,982 11-18-2019 14:41 553a5062 eb_hs245b2c51g0s0900hx.out 503,027 11-19-2019 19:18 1050fff4 eb_hs245b2c51g0s1000hx.inp 3,986 11-18-2019 14:41 bca2294c eb_hs245b2c51g0s1000hx.out 505,414 11-19-2019 19:24 4072d6fa eb_hs245b2c51g0s1100hx.inp 3,986 11-18-2019 14:41 b76baac5 eb_hs245b2c51g0s1100hx.out 502,896 11-19-2019 19:38 5ad69041 eb_hs245b2c51g0s1200hx.inp 3,986 11-18-2019 14:41 f849cff0 eb_hs245b2c51g0s1200hx.out 503,882 11-19-2019 19:37 a5b1a1f5 eb_hs245b2c51g0s1300hx.inp 3,986 11-18-2019 14:42 812346da eb_hs245b2c51g0s1300hx.out 504,528 11-19-2019 19:43 260d30f4 eb_hs245b2c51g0s1400hx.inp 3,986 11-18-2019 14:42 91fd6a80 eb_hs245b2c51g0s1400hx.out 503,886 11-19-2019 19:43 79de1c47 eb_hs245b2c51g0s1500hx.inp 3,986 11-18-2019 14:42 7b169de6 eb_hs245b2c51g0s1500hx.out 503,513 11-19-2019 19:47 a2bb4287
\\v1.2\\eb\\hs325\\ (22) 5,573,301 11-20-2019 09:22 eb_hs325b2c51g0s0500hx.inp 3,932 11-18-2019 12:53 3d0a5e35 eb_hs325b2c51g0s0500hx.out 502,779 11-19-2019 13:54 ab7c90ad eb_hs325b2c51g0s0600hx.inp 3,932 11-18-2019 12:53 75486513 eb_hs325b2c51g0s0600hx.out 502,974 11-19-2019 13:55 6f3b1c23 eb_hs325b2c51g0s0700hx.inp 3,932 11-18-2019 12:53 a19d3570 eb_hs325b2c51g0s0700hx.out 504,364 11-19-2019 14:04 2ee000f2 eb_hs325b2c51g0s0800hx.inp 3,932 11-18-2019 12:53 28c233ac eb_hs325b2c51g0s0800hx.out 502,038 11-19-2019 13:57 3f332645 eb_hs325b2c51g0s0900hx.inp 3,932 11-18-2019 12:53 f1cb48f4 eb_hs325b2c51g0s0900hx.out 503,020 11-19-2019 13:55 d2c949b4 eb_hs325b2c51g0s1000hx.inp 3,936 11-18-2019 12:53 928c5d35 eb_hs325b2c51g0s1000hx.out 503,188 11-19-2019 13:56 91a68c8e eb_hs325b2c51g0s1100hx.inp 3,936 11-18-2019 12:54 689af4c3 eb_hs325b2c51g0s1100hx.out 502,586 11-19-2019 14:00 7f548a9c eb_hs325b2c51g0s1200hx.inp 3,936 11-18-2019 12:54 3e7335b6 eb_hs325b2c51g0s1200hx.out 501,764 11-19-2019 14:16 14453d3b eb_hs325b2c51g0s1300hx.inp 3,936 11-18-2019 12:54 949833bb eb_hs325b2c51g0s1300hx.out 502,236 11-19-2019 14:03 f2acf594 eb_hs325b2c51g0s1400hx.inp 3,936 11-18-2019 12:54 c95be573 eb_hs325b2c51g0s1400hx.out 502,676 11-19-2019 14:08 a827db77 eb_hs325b2c51g0s1500hx.inp 3,936 11-18-2019 12:54 2b570ace eb_hs325b2c51g0s1500hx.out 502,400 11-19-2019 14:12 c5bf8eda
\\v1.2\\eb\\na245\\ (22) 5,584,332 11-20-2019 09:22 eb_na245b2c51g0s0500hx.inp 3,980 11-18-2019 11:30 27fd9cc4 eb_na245b2c51g0s0500hx.out 503,056 11-19-2019 07:03 437cf356 eb_na245b2c51g0s0600hx.inp 3,981 11-18-2019 11:30 e7f66a21 eb_na245b2c51g0s0600hx.out 504,025 11-19-2019 06:47 6a05d2e3 eb_na245b2c51g0s0700hx.inp 3,981 11-18-2019 11:31 c4a28031 eb_na245b2c51g0s0700hx.out 502,778 11-19-2019 07:06 c72f1077 eb_na245b2c51g0s0800hx.inp 3,981 11-18-2019 11:31 815e412f eb_na245b2c51g0s0800hx.out 503,485 11-19-2019 07:03 a62c1b8c eb_na245b2c51g0s0900hx.inp 3,981 11-18-2019 11:31 24fca51e eb_na245b2c51g0s0900hx.out 504,451 11-19-2019 07:00 a7bdc77b eb_na245b2c51g0s1000hx.inp 3,985 11-18-2019 11:31 4858bad9 eb_na245b2c51g0s1000hx.out 502,755 11-19-2019 07:09 29405e8d eb_na245b2c51g0s1100hx.inp 3,985 11-18-2019 11:31 64bc7ffa eb_na245b2c51g0s1100hx.out 503,293 11-19-2019 07:05 bfba67d3 eb_na245b2c51g0s1200hx.inp 3,985 11-18-2019 11:31 ced539b8 eb_na245b2c51g0s1200hx.out 504,142 11-19-2019 07:10 75105454 eb_na245b2c51g0s1300hx.inp 3,985 11-18-2019 11:31 081758fb eb_na245b2c51g0s1300hx.out 503,303 11-19-2019 07:09 073f16c1 eb_na245b2c51g0s1400hx.inp 3,985 11-18-2019 11:31 859a1023 eb_na245b2c51g0s1400hx.out 504,364 11-19-2019 07:10 95dc29ec eb_na245b2c51g0s1500hx.inp 3,985 11-18-2019 11:31 1829d794 eb_na245b2c51g0s1500hx.out 504,866 11-19-2019 07:12 6727c741
\\v1.2\\eb\\na325\\ (22) 5,571,891 11-20-2019 09:22 eb_na325b2c51g0s0500hx.inp 3,931 11-18-2019 10:27 18e0f333
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
114 of 190 eb_na325b2c51g0s0500hx.out 501,858 11-18-2019 23:15 5ff03a72 eb_na325b2c51g0s0600hx.inp 3,931 11-18-2019 10:27 74ddda7e eb_na325b2c51g0s0600hx.out 501,856 11-18-2019 23:02 a1a9c621 eb_na325b2c51g0s0700hx.inp 3,931 11-18-2019 10:28 4f1516d5 eb_na325b2c51g0s0700hx.out 502,664 11-18-2019 22:50 2e2d0b21 eb_na325b2c51g0s0800hx.inp 3,931 11-18-2019 10:28 87d94cc0 eb_na325b2c51g0s0800hx.out 502,558 11-18-2019 22:58 212b9362 eb_na325b2c51g0s0900hx.inp 3,931 11-18-2019 10:28 3beff83c eb_na325b2c51g0s0900hx.out 502,922 11-18-2019 23:03 2ca9d588 eb_na325b2c51g0s1000hx.inp 3,935 11-18-2019 10:28 ae00ffa6 eb_na325b2c51g0s1000hx.out 503,055 11-18-2019 23:00 491fda83 eb_na325b2c51g0s1100hx.inp 3,935 11-18-2019 10:28 1edae49c eb_na325b2c51g0s1100hx.out 502,251 11-18-2019 23:01 34dfcb00 eb_na325b2c51g0s1200hx.inp 3,935 11-18-2019 10:28 1d9d162b eb_na325b2c51g0s1200hx.out 502,854 11-18-2019 23:08 6719c22a eb_na325b2c51g0s1300hx.inp 3,935 11-18-2019 10:28 564dfacb eb_na325b2c51g0s1300hx.out 503,162 11-18-2019 23:09 b7fe2f89 eb_na325b2c51g0s1400hx.inp 3,935 11-18-2019 10:28 93311add eb_na325b2c51g0s1400hx.out 502,170 11-18-2019 23:18 9e0659b7 eb_na325b2c51g0s1500hx.inp 3,935 11-18-2019 10:28 cc08e077 eb_na325b2c51g0s1500hx.out 503,276 11-18-2019 23:16 cbb88213
\\v1.2\\eb\\ns245\\ (22) 5,587,182 11-20-2019 09:22 eb_ns245b2c51g0s0500hx.inp 3,981 11-18-2019 17:13 b3539e7c eb_ns245b2c51g0s0500hx.out 504,054 11-20-2019 05:49 f092eab6 eb_ns245b2c51g0s0600hx.inp 3,982 11-18-2019 17:13 a8ea7c75 eb_ns245b2c51g0s0600hx.out 504,887 11-20-2019 05:37 46fafe46 eb_ns245b2c51g0s0700hx.inp 3,982 11-18-2019 17:13 abdf1454 eb_ns245b2c51g0s0700hx.out 503,725 11-20-2019 05:35 0d5f12ca eb_ns245b2c51g0s0800hx.inp 3,982 11-18-2019 17:13 ac79e990 eb_ns245b2c51g0s0800hx.out 503,562 11-20-2019 05:26 bafe0ba8 eb_ns245b2c51g0s0900hx.inp 3,982 11-18-2019 17:13 e13f375a eb_ns245b2c51g0s0900hx.out 503,965 11-20-2019 05:30 ae29fa13 eb_ns245b2c51g0s1000hx.inp 3,986 11-18-2019 17:13 85228719 eb_ns245b2c51g0s1000hx.out 504,348 11-20-2019 05:40 b987d659 eb_ns245b2c51g0s1100hx.inp 3,986 11-18-2019 17:13 8eeb0490 eb_ns245b2c51g0s1100hx.out 503,492 11-20-2019 05:41 308a0a38 eb_ns245b2c51g0s1200hx.inp 3,986 11-18-2019 17:13 c1c961a5 eb_ns245b2c51g0s1200hx.out 504,182 11-20-2019 05:40 549b738c eb_ns245b2c51g0s1300hx.inp 3,986 11-18-2019 17:13 b8a3e88f eb_ns245b2c51g0s1300hx.out 503,560 11-20-2019 05:32 a802b591 eb_ns245b2c51g0s1400hx.inp 3,986 11-18-2019 17:13 a87dc4d5 eb_ns245b2c51g0s1400hx.out 503,482 11-20-2019 05:46 c420ebe4 eb_ns245b2c51g0s1500hx.inp 3,986 11-18-2019 17:14 429633b3 eb_ns245b2c51g0s1500hx.out 504,100 11-20-2019 05:46 5d1a7354
\\v1.2\\eb\\ns325\\ (22) 5,572,860 11-20-2019 09:22 eb_ns325b2c51g0s0500hx.inp 3,932 11-18-2019 16:08 4729854b eb_ns325b2c51g0s0500hx.out 503,175 11-20-2019 00:18 ffe55e3b eb_ns325b2c51g0s0600hx.inp 3,932 11-18-2019 16:08 0f6bbe6d eb_ns325b2c51g0s0600hx.out 503,365 11-20-2019 00:28 96bc75e0 eb_ns325b2c51g0s0700hx.inp 3,932 11-18-2019 16:08 dbbeee0e eb_ns325b2c51g0s0700hx.out 502,488 11-20-2019 00:22 fc53c38f eb_ns325b2c51g0s0800hx.inp 3,932 11-18-2019 16:08 52e1e8d2 eb_ns325b2c51g0s0800hx.out 502,797 11-20-2019 00:23 fb4db251 eb_ns325b2c51g0s0900hx.inp 3,932 11-18-2019 16:08 8be8938a eb_ns325b2c51g0s0900hx.out 502,441 11-20-2019 00:43 ae2a6c7f eb_ns325b2c51g0s1000hx.inp 3,936 11-18-2019 16:08 5be5af97 eb_ns325b2c51g0s1000hx.out 502,434 11-20-2019 00:26 2d8fb134 eb_ns325b2c51g0s1100hx.inp 3,936 11-18-2019 16:09 a1f30661 eb_ns325b2c51g0s1100hx.out 501,969 11-20-2019 00:28 7f1dd6fe eb_ns325b2c51g0s1200hx.inp 3,936 11-18-2019 16:09 f71ac714 eb_ns325b2c51g0s1200hx.out 502,788 11-20-2019 00:32 0afb1d8e eb_ns325b2c51g0s1300hx.inp 3,936 11-18-2019 16:09 5df1c119 eb_ns325b2c51g0s1300hx.out 502,469 11-20-2019 00:33 c5e73b50 eb_ns325b2c51g0s1400hx.inp 3,936 11-18-2019 16:09 003217d1 eb_ns325b2c51g0s1400hx.out 502,820 11-20-2019 00:29 e7bacfda eb_ns325b2c51g0s1500hx.inp 3,936 11-18-2019 16:09 e23ef86c eb_ns325b2c51g0s1500hx.out 502,838 11-20-2019 00:40 f3d81fe4
\\v1.2\\ec\\ (0) 56,778,215 11-18-2019 17:14
\\v1.2\\ec\\ha245\\ (22) 7,195,036 11-18-2019 20:33 ec_ha245c2c51g0s0500hx.inp 3,955 11-18-2019 02:17 2d01e5a2 ec_ha245c2c51g0s0500hx.out 650,441 11-18-2019 15:37 65ffd9d0 ec_ha245c2c51g0s0600hx.inp 3,956 11-18-2019 02:17 06cc9667 ec_ha245c2c51g0s0600hx.out 650,933 11-18-2019 15:40 5547d64a
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
115 of 190 ec_ha245c2c51g0s0700hx.inp 3,956 11-18-2019 02:17 54efc71e ec_ha245c2c51g0s0700hx.out 649,777 11-18-2019 15:26 856ee185 ec_ha245c2c51g0s0800hx.inp 3,956 11-18-2019 02:17 8bfaa23d ec_ha245c2c51g0s0800hx.out 649,768 11-18-2019 15:37 ed2efcc0 ec_ha245c2c51g0s0900hx.inp 3,956 11-18-2019 02:17 0461b0d3 ec_ha245c2c51g0s0900hx.out 650,203 11-18-2019 15:39 a4ca6f5c ec_ha245c2c51g0s1000hx.inp 3,960 11-18-2019 02:17 44ab297d ec_ha245c2c51g0s1000hx.out 649,570 11-18-2019 15:27 193688d1 ec_ha245c2c51g0s1100hx.inp 3,960 11-18-2019 02:17 970fb0cf ec_ha245c2c51g0s1100hx.out 650,650 11-18-2019 15:36 659fd5a4 ec_ha245c2c51g0s1200hx.inp 3,960 11-18-2019 02:17 fd047e7d ec_ha245c2c51g0s1200hx.out 650,189 11-18-2019 15:40 9387e8dd ec_ha245c2c51g0s1300hx.inp 3,960 11-18-2019 02:17 baa46a7e ec_ha245c2c51g0s1300hx.out 650,040 11-18-2019 15:40 b9539c09 ec_ha245c2c51g0s1400hx.inp 3,960 11-18-2019 02:17 fd8801ce ec_ha245c2c51g0s1400hx.out 649,802 11-18-2019 15:40 abd074d5 ec_ha245c2c51g0s1500hx.inp 3,960 11-18-2019 02:18 e1f3be7d ec_ha245c2c51g0s1500hx.out 650,124 11-18-2019 15:53 0dd0beb9
\\v1.2\\ec\\ha325\\ (22) 7,181,105 11-18-2019 20:33 ec_ha325c2c51g0s0500hx.inp 3,901 11-18-2019 00:23 3c7e497a ec_ha325c2c51g0s0500hx.out 648,335 11-18-2019 03:38 c44f6807 ec_ha325c2c51g0s0600hx.inp 3,901 11-18-2019 00:23 712917b1 ec_ha325c2c51g0s0600hx.out 648,909 11-18-2019 03:31 c8eb042b ec_ha325c2c51g0s0700hx.inp 3,901 11-18-2019 00:23 36e58dca ec_ha325c2c51g0s0700hx.out 648,214 11-18-2019 03:25 71f14564 ec_ha325c2c51g0s0800hx.inp 3,901 11-18-2019 00:23 755c682a ec_ha325c2c51g0s0800hx.out 649,075 11-18-2019 03:20 c51b6704 ec_ha325c2c51g0s0900hx.inp 3,901 11-18-2019 00:23 c21f985a ec_ha325c2c51g0s0900hx.out 648,136 11-18-2019 03:16 c747db7d ec_ha325c2c51g0s1000hx.inp 3,905 11-18-2019 00:23 600a8d4b ec_ha325c2c51g0s1000hx.out 648,447 11-18-2019 03:30 69efdcdd ec_ha325c2c51g0s1100hx.inp 3,905 11-18-2019 00:23 4014bda8 ec_ha325c2c51g0s1100hx.out 648,732 11-18-2019 03:27 551a43d3 ec_ha325c2c51g0s1200hx.inp 3,905 11-18-2019 00:23 a1961e1d ec_ha325c2c51g0s1200hx.out 650,120 11-18-2019 03:26 6de31a78 ec_ha325c2c51g0s1300hx.inp 3,905 11-18-2019 00:24 6b3f8d57 ec_ha325c2c51g0s1300hx.out 649,524 11-18-2019 03:23 d4520987 ec_ha325c2c51g0s1400hx.inp 3,905 11-18-2019 00:24 0694ebed ec_ha325c2c51g0s1400hx.out 649,195 11-18-2019 03:24 1b846a72 ec_ha325c2c51g0s1500hx.inp 3,905 11-18-2019 00:24 4b183b8d ec_ha325c2c51g0s1500hx.out 649,483 11-18-2019 03:26 6fe6a7d3
\\v1.2\\ec\\hs245\\ (22) 7,191,085 11-20-2019 09:22 ec_hs245c2c51g0s0500hx.inp 3,983 11-18-2019 14:42 0481789c ec_hs245c2c51g0s0500hx.out 649,556 11-19-2019 19:27 ae0cf1b8 ec_hs245c2c51g0s0600hx.inp 3,984 11-18-2019 14:42 02a7fe52 ec_hs245c2c51g0s0600hx.out 649,596 11-19-2019 19:34 97b660e8 ec_hs245c2c51g0s0700hx.inp 3,984 11-18-2019 14:42 8cbcb5a4 ec_hs245c2c51g0s0700hx.out 649,158 11-19-2019 19:25 07278055 ec_hs245c2c51g0s0800hx.inp 3,984 11-18-2019 14:42 b4b8dbea ec_hs245c2c51g0s0800hx.out 649,992 11-19-2019 19:25 2a8d4b5e ec_hs245c2c51g0s0900hx.inp 3,984 11-18-2019 14:42 957a41ee ec_hs245c2c51g0s0900hx.out 649,289 11-19-2019 19:19 f9c21704 ec_hs245c2c51g0s1000hx.inp 3,988 11-18-2019 14:42 897222d5 ec_hs245c2c51g0s1000hx.out 650,326 11-19-2019 19:28 8b487c36 ec_hs245c2c51g0s1100hx.inp 3,988 11-18-2019 14:42 163414ad ec_hs245c2c51g0s1100hx.out 649,848 11-19-2019 19:26 2e92dd83 ec_hs245c2c51g0s1200hx.inp 3,988 11-18-2019 14:42 4e3e1284 ec_hs245c2c51g0s1200hx.out 650,597 11-19-2019 19:24 82d8c39b ec_hs245c2c51g0s1300hx.inp 3,988 11-18-2019 14:43 faee902a ec_hs245c2c51g0s1300hx.out 649,323 11-19-2019 19:28 1a8f13cd ec_hs245c2c51g0s1400hx.inp 3,988 11-18-2019 14:43 32c9d67a ec_hs245c2c51g0s1400hx.out 649,375 11-19-2019 19:27 6b8fd907 ec_hs245c2c51g0s1500hx.inp 3,988 11-18-2019 14:43 23f43571 ec_hs245c2c51g0s1500hx.out 650,178 11-19-2019 19:27 85349564
\\v1.2\\ec\\hs325\\ (22) 7,186,052 11-20-2019 09:22 ec_hs325c2c51g0s0500hx.inp 3,934 11-18-2019 12:54 f555d2c4 ec_hs325c2c51g0s0500hx.out 649,168 11-19-2019 13:41 c62ad95e ec_hs325c2c51g0s0600hx.inp 3,934 11-18-2019 12:54 7afb35da ec_hs325c2c51g0s0600hx.out 649,514 11-19-2019 13:32 61ccf164 ec_hs325c2c51g0s0700hx.inp 3,934 11-18-2019 12:54 9d86f081 ec_hs325c2c51g0s0700hx.out 649,581 11-19-2019 14:06 c6651035 ec_hs325c2c51g0s0800hx.inp 3,934 11-18-2019 12:54 6aac0b42 ec_hs325c2c51g0s0800hx.out 649,235 11-19-2019 13:39 b7617fc3 ec_hs325c2c51g0s0900hx.inp 3,934 11-18-2019 12:54 324ae18d ec_hs325c2c51g0s0900hx.out 649,512 11-19-2019 13:37 a71e94eb
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
116 of 190 ec_hs325c2c51g0s1000hx.inp 3,938 11-18-2019 12:54 3a0fbb37 ec_hs325c2c51g0s1000hx.out 648,683 11-19-2019 13:46 146579dd ec_hs325c2c51g0s1100hx.inp 3,938 11-18-2019 12:55 4307b609 ec_hs325c2c51g0s1100hx.out 650,119 11-19-2019 13:43 aaecb52a ec_hs325c2c51g0s1200hx.inp 3,938 11-18-2019 12:55 7322312d ec_hs325c2c51g0s1200hx.out 648,936 11-19-2019 13:43 342c8912 ec_hs325c2c51g0s1300hx.inp 3,938 11-18-2019 12:55 ab9d36d1 ec_hs325c2c51g0s1300hx.out 648,865 11-19-2019 13:48 32d8cafc ec_hs325c2c51g0s1400hx.inp 3,938 11-18-2019 12:55 ce88bd73 ec_hs325c2c51g0s1400hx.out 649,421 11-19-2019 13:56 291f3e17 ec_hs325c2c51g0s1500hx.inp 3,938 11-18-2019 12:55 35313dc4 ec_hs325c2c51g0s1500hx.out 649,720 11-19-2019 13:52 eacc4dac
\\v1.2\\ec\\na245\\ (22) 7,196,887 11-20-2019 09:22 ec_na245c2c51g0s0500hx.inp 3,982 11-18-2019 11:31 a98bfa3e ec_na245c2c51g0s0500hx.out 650,901 11-19-2019 07:00 296ba4c9 ec_na245c2c51g0s0600hx.inp 3,983 11-18-2019 11:31 898eaf7c ec_na245c2c51g0s0600hx.out 649,207 11-19-2019 07:05 f778a993 ec_na245c2c51g0s0700hx.inp 3,983 11-18-2019 11:31 450904e8 ec_na245c2c51g0s0700hx.out 650,698 11-19-2019 06:56 f192e41b ec_na245c2c51g0s0800hx.inp 3,983 11-18-2019 11:32 9bd18d23 ec_na245c2c51g0s0800hx.out 650,682 11-19-2019 06:55 e85952bd ec_na245c2c51g0s0900hx.inp 3,983 11-18-2019 11:32 bef45438 ec_na245c2c51g0s0900hx.out 650,474 11-19-2019 06:56 4b4c7771 ec_na245c2c51g0s1000hx.inp 3,987 11-18-2019 11:32 5ff60047 ec_na245c2c51g0s1000hx.out 649,869 11-19-2019 07:06 95aaf5c7 ec_na245c2c51g0s1100hx.inp 3,987 11-18-2019 11:32 dcc57d3b ec_na245c2c51g0s1100hx.out 650,813 11-19-2019 07:08 444b0037 ec_na245c2c51g0s1200hx.inp 3,987 11-18-2019 11:32 e42867dd ec_na245c2c51g0s1200hx.out 649,920 11-19-2019 07:05 328cfcd3 ec_na245c2c51g0s1300hx.inp 3,987 11-18-2019 11:32 a15b0e4c ec_na245c2c51g0s1300hx.out 649,968 11-19-2019 06:59 3b9cb4ef ec_na245c2c51g0s1400hx.inp 3,987 11-18-2019 11:32 2252dc15 ec_na245c2c51g0s1400hx.out 649,727 11-19-2019 07:12 a584f6cb ec_na245c2c51g0s1500hx.inp 3,987 11-18-2019 11:32 05b2b935 ec_na245c2c51g0s1500hx.out 650,792 11-19-2019 07:07 e806a5e0
\\v1.2\\ec\\na325\\ (22) 7,183,804 11-20-2019 09:22 ec_na325c2c51g0s0500hx.inp 3,933 11-18-2019 10:28 167fed4c ec_na325c2c51g0s0500hx.out 648,839 11-18-2019 22:54 121faa23 ec_na325c2c51g0s0600hx.inp 3,933 11-18-2019 10:28 ec1af149 ec_na325c2c51g0s0600hx.out 648,722 11-18-2019 22:51 4ec8591e ec_na325c2c51g0s0700hx.inp 3,933 11-18-2019 10:29 b9a4252f ec_na325c2c51g0s0700hx.out 648,918 11-18-2019 22:46 ca0cab4b ec_na325c2c51g0s0800hx.inp 3,933 11-18-2019 10:29 0e5feba2 ec_na325c2c51g0s0800hx.out 649,254 11-18-2019 22:51 c8f372ac ec_na325c2c51g0s0900hx.inp 3,933 11-18-2019 10:29 0e376774 ec_na325c2c51g0s0900hx.out 648,954 11-18-2019 22:49 4857c04c ec_na325c2c51g0s1000hx.inp 3,937 11-18-2019 10:29 a5c00d85 ec_na325c2c51g0s1000hx.out 648,979 11-18-2019 22:54 31da6066 ec_na325c2c51g0s1100hx.inp 3,937 11-18-2019 10:29 012c3543 ec_na325c2c51g0s1100hx.out 648,615 11-18-2019 23:19 9d3a445f ec_na325c2c51g0s1200hx.inp 3,937 11-18-2019 10:29 ba174af6 ec_na325c2c51g0s1200hx.out 651,202 11-18-2019 22:53 c0d15f18 ec_na325c2c51g0s1300hx.inp 3,937 11-18-2019 10:29 16d67b8a ec_na325c2c51g0s1300hx.out 648,724 11-18-2019 22:51 97d1622d ec_na325c2c51g0s1400hx.inp 3,937 11-18-2019 10:29 83ef2e20 ec_na325c2c51g0s1400hx.out 649,229 11-18-2019 22:52 88fe8d69 ec_na325c2c51g0s1500hx.inp 3,937 11-18-2019 10:29 6344b31c ec_na325c2c51g0s1500hx.out 649,081 11-18-2019 23:05 d838dda7
\\v1.2\\ec\\ns245\\ (22) 6,608,058 11-20-2019 09:22 ec_ns245c2c51g0s0500hx.inp 3,983 11-18-2019 17:14 1edec8ca ec_ns245c2c51g0s0500hx.out 503,788 11-20-2019 05:38 fb6777cd ec_ns245c2c51g0s0600hx.inp 3,984 11-18-2019 17:14 b25c588c ec_ns245c2c51g0s0600hx.out 504,163 11-20-2019 05:39 2eaa571c ec_ns245c2c51g0s0700hx.inp 3,984 11-18-2019 17:14 3c47137a ec_ns245c2c51g0s0700hx.out 505,102 11-20-2019 05:26 1a6cf955 ec_ns245c2c51g0s0800hx.inp 3,984 11-18-2019 17:14 04437d34 ec_ns245c2c51g0s0800hx.out 503,270 11-20-2019 05:31 3b1dfe7a ec_ns245c2c51g0s0900hx.inp 3,984 11-18-2019 17:14 2581e730 ec_ns245c2c51g0s0900hx.out 650,010 11-20-2019 05:34 0a93d8ff ec_ns245c2c51g0s1000hx.inp 3,988 11-18-2019 17:14 0b626670 ec_ns245c2c51g0s1000hx.out 649,902 11-20-2019 05:32 bfa5f531 ec_ns245c2c51g0s1100hx.inp 3,988 11-18-2019 17:14 94245008 ec_ns245c2c51g0s1100hx.out 649,164 11-20-2019 05:30 1cb77f0c ec_ns245c2c51g0s1200hx.inp 3,988 11-18-2019 17:14 cc2e5621 ec_ns245c2c51g0s1200hx.out 649,252 11-20-2019 05:37 0b608b60
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
117 of 190 ec_ns245c2c51g0s1300hx.inp 3,988 11-18-2019 17:14 78fed48f ec_ns245c2c51g0s1300hx.out 650,393 11-20-2019 05:33 0846b1eb ec_ns245c2c51g0s1400hx.inp 3,988 11-18-2019 17:14 b0d992df ec_ns245c2c51g0s1400hx.out 649,491 11-20-2019 05:36 5e2f20e5 ec_ns245c2c51g0s1500hx.inp 3,988 11-18-2019 17:15 a1e471d4 ec_ns245c2c51g0s1500hx.out 649,676 11-20-2019 05:35 3573ac56
\\v1.2\\ec\\ns325\\ (22) 7,036,188 11-20-2019 09:22 ec_ns325c2c51g0s0500hx.inp 3,934 11-18-2019 16:09 215aad18 ec_ns325c2c51g0s0500hx.out 502,519 11-20-2019 00:11 b62598a4 ec_ns325c2c51g0s0600hx.inp 3,934 11-18-2019 16:09 aef44a06 ec_ns325c2c51g0s0600hx.out 649,142 11-20-2019 00:39 f1019a36 ec_ns325c2c51g0s0700hx.inp 3,934 11-18-2019 16:09 49898f5d ec_ns325c2c51g0s0700hx.out 648,500 11-20-2019 00:08 4d180785 ec_ns325c2c51g0s0800hx.inp 3,934 11-18-2019 16:09 bea3749e ec_ns325c2c51g0s0800hx.out 649,281 11-20-2019 00:06 37275508 ec_ns325c2c51g0s0900hx.inp 3,934 11-18-2019 16:09 e6459e51 ec_ns325c2c51g0s0900hx.out 648,480 11-20-2019 00:06 10260141 ec_ns325c2c51g0s1000hx.inp 3,938 11-18-2019 16:09 813f65de ec_ns325c2c51g0s1000hx.out 649,074 11-20-2019 00:10 faa8895d ec_ns325c2c51g0s1100hx.inp 3,938 11-18-2019 16:10 f83768e0 ec_ns325c2c51g0s1100hx.out 648,784 11-20-2019 00:10 5bd44f9b ec_ns325c2c51g0s1200hx.inp 3,938 11-18-2019 16:10 c812efc4 ec_ns325c2c51g0s1200hx.out 649,434 11-20-2019 00:18 28193bf0 ec_ns325c2c51g0s1300hx.inp 3,938 11-18-2019 16:10 10ade838 ec_ns325c2c51g0s1300hx.out 649,247 11-20-2019 00:13 673ce136 ec_ns325c2c51g0s1400hx.inp 3,938 11-18-2019 16:10 75b8639a ec_ns325c2c51g0s1400hx.out 649,011 11-20-2019 00:17 3572918d ec_ns325c2c51g0s1500hx.inp 3,938 11-18-2019 16:10 8e01e32d ec_ns325c2c51g0s1500hx.out 649,418 11-20-2019 00:25 88e71185
\\v1.2\\ed\\ (0) 51,071,723 11-18-2019 17:15
\\v1.2\\ed\\ha245\\ (22) 7,194,490 11-18-2019 20:33 ed_ha245c2c51g0s0500hx.inp 3,956 11-18-2019 02:18 63978c9b ed_ha245c2c51g0s0500hx.out 649,198 11-18-2019 15:49 32999c75 ed_ha245c2c51g0s0600hx.inp 3,957 11-18-2019 02:18 22eb63b0 ed_ha245c2c51g0s0600hx.out 650,255 11-18-2019 15:47 36f58a1d ed_ha245c2c51g0s0700hx.inp 3,957 11-18-2019 02:18 cf39cbfa ed_ha245c2c51g0s0700hx.out 649,689 11-18-2019 15:45 2cff5d9a ed_ha245c2c51g0s0800hx.inp 3,957 11-18-2019 02:18 a039951c ed_ha245c2c51g0s0800hx.out 649,826 11-18-2019 15:43 f21fd332 ed_ha245c2c51g0s0900hx.inp 3,957 11-18-2019 02:18 5a2fb383 ed_ha245c2c51g0s0900hx.out 650,788 11-18-2019 15:44 836d09bb ed_ha245c2c51g0s1000hx.inp 3,961 11-18-2019 02:18 2b9474c6 ed_ha245c2c51g0s1000hx.out 650,129 11-18-2019 15:46 987bc62e ed_ha245c2c51g0s1100hx.inp 3,961 11-18-2019 02:18 2662bed8 ed_ha245c2c51g0s1100hx.out 650,260 11-18-2019 15:36 53769cc6 ed_ha245c2c51g0s1200hx.inp 3,961 11-18-2019 02:18 59f31b59 ed_ha245c2c51g0s1200hx.out 649,962 11-18-2019 15:45 4deb593b ed_ha245c2c51g0s1300hx.inp 3,961 11-18-2019 02:18 92fa7522 ed_ha245c2c51g0s1300hx.out 650,449 11-18-2019 15:50 60f7c734 ed_ha245c2c51g0s1400hx.inp 3,961 11-18-2019 02:18 025b0261 ed_ha245c2c51g0s1400hx.out 649,790 11-18-2019 15:47 710c9dc3 ed_ha245c2c51g0s1500hx.inp 3,961 11-18-2019 02:18 6b86a7bf ed_ha245c2c51g0s1500hx.out 650,594 11-18-2019 15:50 c071816f
\\v1.2\\ed\\ha325\\ (22) 7,179,987 11-18-2019 20:33 ed_ha325c2c51g0s0500hx.inp 3,902 11-18-2019 00:24 49dbacbb ed_ha325c2c51g0s0500hx.out 648,221 11-18-2019 03:35 ce57abb6 ed_ha325c2c51g0s0600hx.inp 3,902 11-18-2019 00:24 3dc5b38a ed_ha325c2c51g0s0600hx.out 648,561 11-18-2019 03:32 62e48a80 ed_ha325c2c51g0s0700hx.inp 3,902 11-18-2019 00:24 8ecb6b96 ed_ha325c2c51g0s0700hx.out 649,178 11-18-2019 03:18 d6cd90cf ed_ha325c2c51g0s0800hx.inp 3,902 11-18-2019 00:24 f5377d4c ed_ha325c2c51g0s0800hx.out 648,906 11-18-2019 03:54 b3af0d5a ed_ha325c2c51g0s0900hx.inp 3,902 11-18-2019 00:24 513c3f32 ed_ha325c2c51g0s0900hx.out 648,353 11-18-2019 03:19 707d8941 ed_ha325c2c51g0s1000hx.inp 3,906 11-18-2019 00:24 47ea2e66 ed_ha325c2c51g0s1000hx.out 649,082 11-18-2019 03:23 2a572aef ed_ha325c2c51g0s1100hx.inp 3,906 11-18-2019 00:24 1442de61 ed_ha325c2c51g0s1100hx.out 648,990 11-18-2019 03:17 2d6fec77 ed_ha325c2c51g0s1200hx.inp 3,906 11-18-2019 00:24 62dd2d15 ed_ha325c2c51g0s1200hx.out 648,853 11-18-2019 03:24 004fe7d7 ed_ha325c2c51g0s1300hx.inp 3,906 11-18-2019 00:25 9213b991 ed_ha325c2c51g0s1300hx.out 649,228 11-18-2019 03:24 ddbb9da5 ed_ha325c2c51g0s1400hx.inp 3,906 11-18-2019 00:25 241033ff
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
118 of 190 ed_ha325c2c51g0s1400hx.out 648,868 11-18-2019 03:29 d9c64c90 ed_ha325c2c51g0s1500hx.inp 3,906 11-18-2019 00:25 55aa8175 ed_ha325c2c51g0s1500hx.out 648,801 11-18-2019 03:29 043cda33
\\v1.2\\ed\\hs245\\ (22) 5,585,037 11-20-2019 09:22 ed_hs245c2c51g0s0500hx.inp 3,984 11-18-2019 14:43 a7623b14 ed_hs245c2c51g0s0500hx.out 504,059 11-19-2019 19:31 3cc8af85 ed_hs245c2c51g0s0600hx.inp 3,985 11-18-2019 14:43 3fb6abd0 ed_hs245c2c51g0s0600hx.out 502,757 11-19-2019 19:30 56a565db ed_hs245c2c51g0s0700hx.inp 3,985 11-18-2019 14:43 bb1fda10 ed_hs245c2c51g0s0700hx.out 503,655 11-19-2019 19:20 384c6bf4 ed_hs245c2c51g0s0800hx.inp 3,985 11-18-2019 14:43 a656a63f ed_hs245c2c51g0s0800hx.out 503,642 11-19-2019 19:30 9b298593 ed_hs245c2c51g0s0900hx.inp 3,985 11-18-2019 14:43 285cdef6 ed_hs245c2c51g0s0900hx.out 503,395 11-19-2019 19:28 ebfd26d9 ed_hs245c2c51g0s1000hx.inp 3,989 11-18-2019 14:43 6d477f9a ed_hs245c2c51g0s1000hx.out 503,380 11-19-2019 19:28 1fbc9c2d ed_hs245c2c51g0s1100hx.inp 3,989 11-18-2019 14:43 8589b305 ed_hs245c2c51g0s1100hx.out 503,921 11-19-2019 19:29 68ca3202 ed_hs245c2c51g0s1200hx.inp 3,989 11-18-2019 14:43 00fb4821 ed_hs245c2c51g0s1200hx.out 504,241 11-19-2019 19:27 3f85822b ed_hs245c2c51g0s1300hx.inp 3,989 11-18-2019 14:44 23be2270 ed_hs245c2c51g0s1300hx.out 504,016 11-19-2019 19:31 71d56b66 ed_hs245c2c51g0s1400hx.inp 3,989 11-18-2019 14:44 bd99fcbe ed_hs245c2c51g0s1400hx.out 503,697 11-19-2019 19:30 541f467a ed_hs245c2c51g0s1500hx.inp 3,989 11-18-2019 14:44 e16d8cae ed_hs245c2c51g0s1500hx.out 504,416 11-19-2019 19:31 df48a374
\\v1.2\\ed\\hs325\\ (22) 5,574,020 11-20-2019 09:22 ed_hs325c2c51g0s0500hx.inp 3,935 11-18-2019 12:55 cda38ae7 ed_hs325c2c51g0s0500hx.out 502,883 11-19-2019 13:52 a6cfb2e6 ed_hs325c2c51g0s0600hx.inp 3,935 11-18-2019 12:55 15ac45aa ed_hs325c2c51g0s0600hx.out 502,990 11-19-2019 14:06 56cbadf5 ed_hs325c2c51g0s0700hx.inp 3,935 11-18-2019 12:55 e826b42f ed_hs325c2c51g0s0700hx.out 502,715 11-19-2019 14:01 2824e224 ed_hs325c2c51g0s0800hx.inp 3,935 11-18-2019 12:55 b5a515d6 ed_hs325c2c51g0s0800hx.out 502,213 11-19-2019 13:50 640937e0 ed_hs325c2c51g0s0900hx.inp 3,935 11-18-2019 12:55 a621d108 ed_hs325c2c51g0s0900hx.out 502,305 11-19-2019 13:50 931bfefe ed_hs325c2c51g0s1000hx.inp 3,939 11-18-2019 12:55 ec8370d3 ed_hs325c2c51g0s1000hx.out 502,969 11-19-2019 13:52 6ede9123 ed_hs325c2c51g0s1100hx.inp 3,939 11-18-2019 12:55 3ebcbc55 ed_hs325c2c51g0s1100hx.out 502,484 11-19-2019 13:50 32471ee0 ed_hs325c2c51g0s1200hx.inp 3,939 11-18-2019 12:56 55b9fa20 ed_hs325c2c51g0s1200hx.out 502,507 11-19-2019 14:04 5040e1f5 ed_hs325c2c51g0s1300hx.inp 3,939 11-18-2019 12:56 94e600df ed_hs325c2c51g0s1300hx.out 503,067 11-19-2019 14:13 3fa42c44 ed_hs325c2c51g0s1400hx.inp 3,939 11-18-2019 12:56 cd537fdd ed_hs325c2c51g0s1400hx.out 503,698 11-19-2019 14:12 76473500 ed_hs325c2c51g0s1500hx.inp 3,939 11-18-2019 12:56 4ac0bddd ed_hs325c2c51g0s1500hx.out 502,880 11-19-2019 14:26 42ff02f2
\\v1.2\\ed\\na245\\ (22) 7,197,657 11-20-2019 09:22 ed_na245c2c51g0s0500hx.inp 3,983 11-18-2019 11:32 8d15d2a3 ed_na245c2c51g0s0500hx.out 650,771 11-19-2019 07:02 b7ddaea0 ed_na245c2c51g0s0600hx.inp 3,984 11-18-2019 11:32 3b6b2f8b ed_na245c2c51g0s0600hx.out 650,101 11-19-2019 07:03 3e6cfac4 ed_na245c2c51g0s0700hx.inp 3,984 11-18-2019 11:32 089cbdfe ed_na245c2c51g0s0700hx.out 649,883 11-19-2019 06:58 ade9d31e ed_na245c2c51g0s0800hx.inp 3,984 11-18-2019 11:33 c94c44be ed_na245c2c51g0s0800hx.out 650,846 11-19-2019 07:01 1ca64d8a ed_na245c2c51g0s0900hx.inp 3,984 11-18-2019 11:33 fe27da79 ed_na245c2c51g0s0900hx.out 649,834 11-19-2019 07:11 5b2b5252 ed_na245c2c51g0s1000hx.inp 3,988 11-18-2019 11:33 67546acc ed_na245c2c51g0s1000hx.out 650,109 11-19-2019 06:58 8104b394 ed_na245c2c51g0s1100hx.inp 3,988 11-18-2019 11:33 162ed881 ed_na245c2c51g0s1100hx.out 649,638 11-19-2019 07:11 df8af3f8 ed_na245c2c51g0s1200hx.inp 3,988 11-18-2019 11:33 05eb0e39 ed_na245c2c51g0s1200hx.out 650,178 11-19-2019 07:05 bea1b243 ed_na245c2c51g0s1300hx.inp 3,988 11-18-2019 11:33 d0e14157 ed_na245c2c51g0s1300hx.out 651,075 11-19-2019 07:02 7e7eda77 ed_na245c2c51g0s1400hx.inp 3,988 11-18-2019 11:33 99524971 ed_na245c2c51g0s1400hx.out 650,376 11-19-2019 07:12 440955b3 ed_na245c2c51g0s1500hx.inp 3,988 11-18-2019 11:33 99b2b58b ed_na245c2c51g0s1500hx.out 650,999 11-19-2019 07:06 d3a291c4
\\v1.2\\ed\\na325\\ (22) 7,183,274 11-20-2019 09:22
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
119 of 190 ed_na325c2c51g0s0500hx.inp 3,934 11-18-2019 10:29 9d61a926 ed_na325c2c51g0s0500hx.out 649,305 11-18-2019 23:01 1b6fb5f7 ed_na325c2c51g0s0600hx.inp 3,934 11-18-2019 10:29 95146be2 ed_na325c2c51g0s0600hx.out 648,967 11-18-2019 22:59 761105c7 ed_na325c2c51g0s0700hx.inp 3,934 11-18-2019 10:29 450ead69 ed_na325c2c51g0s0700hx.out 649,078 11-18-2019 22:58 3c3e82c3 ed_na325c2c51g0s0800hx.inp 3,934 11-18-2019 10:30 0d05e47d ed_na325c2c51g0s0800hx.out 649,158 11-18-2019 22:56 388a40e3 ed_na325c2c51g0s0900hx.inp 3,934 11-18-2019 10:30 960c8ba2 ed_na325c2c51g0s0900hx.out 649,081 11-18-2019 22:58 0efe6a95 ed_na325c2c51g0s1000hx.inp 3,938 11-18-2019 10:30 511d8ac0 ed_na325c2c51g0s1000hx.out 648,603 11-18-2019 22:49 016c5039 ed_na325c2c51g0s1100hx.inp 3,938 11-18-2019 10:30 49355c88 ed_na325c2c51g0s1100hx.out 649,173 11-18-2019 23:16 8aefa2e8 ed_na325c2c51g0s1200hx.inp 3,938 11-18-2019 10:30 3ff01620 ed_na325c2c51g0s1200hx.out 649,125 11-18-2019 22:52 453f8efa ed_na325c2c51g0s1300hx.inp 3,938 11-18-2019 10:30 00e27f9f ed_na325c2c51g0s1300hx.out 648,632 11-18-2019 23:00 4e258eb2 ed_na325c2c51g0s1400hx.inp 3,938 11-18-2019 10:30 abae77a6 ed_na325c2c51g0s1400hx.out 649,122 11-18-2019 23:00 96e28c47 ed_na325c2c51g0s1500hx.inp 3,938 11-18-2019 10:30 b864ffbe ed_na325c2c51g0s1500hx.out 649,732 11-18-2019 23:00 b26d85d6
\\v1.2\\ed\\ns245\\ (22) 5,584,516 11-20-2019 09:22 ed_ns245c2c51g0s0500hx.inp 3,984 11-18-2019 17:15 17999dca ed_ns245c2c51g0s0500hx.out 503,513 11-20-2019 05:38 9c56f435 ed_ns245c2c51g0s0600hx.inp 3,985 11-18-2019 17:15 6c84a20a ed_ns245c2c51g0s0600hx.out 503,609 11-20-2019 05:42 c389e134 ed_ns245c2c51g0s0700hx.inp 3,985 11-18-2019 17:15 e82dd3ca ed_ns245c2c51g0s0700hx.out 503,844 11-20-2019 05:40 419077b4 ed_ns245c2c51g0s0800hx.inp 3,985 11-18-2019 17:15 f564afe5 ed_ns245c2c51g0s0800hx.out 504,261 11-20-2019 05:33 8dbabf31 ed_ns245c2c51g0s0900hx.inp 3,985 11-18-2019 17:15 7b6ed72c ed_ns245c2c51g0s0900hx.out 503,289 11-20-2019 05:33 af9bc544 ed_ns245c2c51g0s1000hx.inp 3,989 11-18-2019 17:15 f9903516 ed_ns245c2c51g0s1000hx.out 504,097 11-20-2019 05:44 85626cf8 ed_ns245c2c51g0s1100hx.inp 3,989 11-18-2019 17:15 115ef989 ed_ns245c2c51g0s1100hx.out 503,672 11-20-2019 05:49 fb8dc0fc ed_ns245c2c51g0s1200hx.inp 3,989 11-18-2019 17:15 942c02ad ed_ns245c2c51g0s1200hx.out 503,006 11-20-2019 05:52 d298fd97 ed_ns245c2c51g0s1300hx.inp 3,989 11-18-2019 17:15 b76968fc ed_ns245c2c51g0s1300hx.out 503,158 11-20-2019 05:47 9fd0f070 ed_ns245c2c51g0s1400hx.inp 3,989 11-18-2019 17:15 294eb632 ed_ns245c2c51g0s1400hx.out 503,651 11-20-2019 06:01 f6509e32 ed_ns245c2c51g0s1500hx.inp 3,989 11-18-2019 17:16 75bac622 ed_ns245c2c51g0s1500hx.out 504,558 11-20-2019 05:55 a0195a09
\\v1.2\\ed\\ns325\\ (22) 5,572,742 11-20-2019 09:22 ed_ns325c2c51g0s0500hx.inp 3,935 11-18-2019 16:10 70fb16c8 ed_ns325c2c51g0s0500hx.out 503,249 11-20-2019 00:20 f71766f4 ed_ns325c2c51g0s0600hx.inp 3,935 11-18-2019 16:10 a8f4d985 ed_ns325c2c51g0s0600hx.out 503,048 11-20-2019 00:22 993e3fbb ed_ns325c2c51g0s0700hx.inp 3,935 11-18-2019 16:10 557e2800 ed_ns325c2c51g0s0700hx.out 503,395 11-20-2019 00:33 9fe90d82 ed_ns325c2c51g0s0800hx.inp 3,935 11-18-2019 16:10 08fd89f9 ed_ns325c2c51g0s0800hx.out 502,802 11-20-2019 00:33 c78dcce6 ed_ns325c2c51g0s0900hx.inp 3,935 11-18-2019 16:10 1b794d27 ed_ns325c2c51g0s0900hx.out 501,569 11-20-2019 00:12 bb703168 ed_ns325c2c51g0s1000hx.inp 3,939 11-18-2019 16:10 0707177e ed_ns325c2c51g0s1000hx.out 502,046 11-20-2019 00:33 4f2c2443 ed_ns325c2c51g0s1100hx.inp 3,939 11-18-2019 16:10 d538dbf8 ed_ns325c2c51g0s1100hx.out 502,806 11-20-2019 00:22 6b90acc2 ed_ns325c2c51g0s1200hx.inp 3,939 11-18-2019 16:11 be3d9d8d ed_ns325c2c51g0s1200hx.out 502,802 11-20-2019 00:40 25b1b91e ed_ns325c2c51g0s1300hx.inp 3,939 11-18-2019 16:11 7f626772 ed_ns325c2c51g0s1300hx.out 501,944 11-20-2019 00:35 5c1f34ea ed_ns325c2c51g0s1400hx.inp 3,939 11-18-2019 16:11 26d71870 ed_ns325c2c51g0s1400hx.out 503,793 11-20-2019 00:53 8bfa259b ed_ns325c2c51g0s1500hx.inp 3,939 11-18-2019 16:11 a144da70 ed_ns325c2c51g0s1500hx.out 501,979 11-20-2019 00:55 ea23fad9
\\v1.2\\ee\\ (0) 47,054,188 11-18-2019 17:16
\\v1.2\\ee\\ha245\\ (18) 5,887,781 11-22-2019 12:48 ee_ha245c2c51g0s001vfio.inp 3,956 11-18-2019 02:19 1c203143 ee_ha245c2c51g0s001vfio.out 650,017 11-18-2019 14:38 5bf3dbbd ee_ha245c2c51g0s005vfio.inp 3,956 11-18-2019 02:19 c1149f43
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
120 of 190 ee_ha245c2c51g0s005vfio.out 650,345 11-18-2019 14:24 1a446619 ee_ha245c2c51g0s010vfio.inp 3,956 11-18-2019 02:19 cf141e95 ee_ha245c2c51g0s010vfio.out 650,988 11-18-2019 14:29 4b8979ef ee_ha245c2c51g0s030vfio.inp 3,956 11-18-2019 02:19 77f95038 ee_ha245c2c51g0s030vfio.out 650,235 11-18-2019 14:55 5685bd5b ee_ha245c2c51g0s050vfio.inp 3,956 11-18-2019 02:19 61f9a93f ee_ha245c2c51g0s050vfio.out 650,086 11-18-2019 15:21 06115065 ee_ha245c2c51g0s070vfio.inp 3,956 11-18-2019 02:19 757f7e2f ee_ha245c2c51g0s070vfio.out 650,047 11-18-2019 15:33 352e6dd9 ee_ha245c2c51g0s090vfio.inp 3,956 11-18-2019 02:19 354df4a8 ee_ha245c2c51g0s090vfio.out 649,934 11-18-2019 15:39 c6baa992 ee_ha245c2c51g0s095vfio.inp 3,956 11-18-2019 02:19 253111ee ee_ha245c2c51g0s095vfio.out 650,320 11-18-2019 15:46 0e041509 ee_ha245c2c51g0s100vfio.inp 3,956 11-18-2019 02:19 0461b0d3 ee_ha245c2c51g0s100vfio.out 650,205 11-18-2019 15:43 e50217ec
\\v1.2\\ee\\ha325\\ (18) 5,873,934 11-22-2019 12:48 ee_ha325c2c51g0s001vfio.inp 3,901 11-18-2019 00:25 348c1188 ee_ha325c2c51g0s001vfio.out 649,612 11-18-2019 02:24 1c1c3127 ee_ha325c2c51g0s005vfio.inp 3,901 11-18-2019 00:25 e5a048c5 ee_ha325c2c51g0s005vfio.out 648,871 11-18-2019 03:34 170457cd ee_ha325c2c51g0s010vfio.inp 3,901 11-18-2019 00:25 fb8d888a ee_ha325c2c51g0s010vfio.out 648,522 11-18-2019 03:38 14ec0e4d ee_ha325c2c51g0s030vfio.inp 3,901 11-18-2019 00:25 8459919e ee_ha325c2c51g0s030vfio.out 649,479 11-18-2019 04:16 498ac16e ee_ha325c2c51g0s050vfio.inp 3,901 11-18-2019 00:25 d270f4ec ee_ha325c2c51g0s050vfio.out 648,337 11-18-2019 04:44 24662e8f ee_ha325c2c51g0s070vfio.inp 3,901 11-18-2019 00:25 dea530a3 ee_ha325c2c51g0s070vfio.out 648,724 11-18-2019 04:52 b5f26368 ee_ha325c2c51g0s090vfio.inp 3,901 11-18-2019 00:25 da5c6266 ee_ha325c2c51g0s090vfio.out 648,139 11-18-2019 05:03 93145ebd ee_ha325c2c51g0s095vfio.inp 3,901 11-18-2019 00:25 32003e36 ee_ha325c2c51g0s095vfio.out 649,001 11-18-2019 05:19 2b887212 ee_ha325c2c51g0s100vfio.inp 3,901 11-18-2019 00:25 c21f985a ee_ha325c2c51g0s100vfio.out 648,140 11-18-2019 05:22 c6948a9b
\\v1.2\\ee\\hs245\\ (18) 5,888,060 11-22-2019 12:48 ee_hs245c2c51g0s001vfi.inp 3,984 11-18-2019 14:44 247ca081 ee_hs245c2c51g0s001vfi.out 650,221 11-19-2019 19:11 2a1d07de ee_hs245c2c51g0s005vfi.inp 3,984 11-18-2019 14:44 6164beef ee_hs245c2c51g0s005vfi.out 650,880 11-19-2019 18:52 f0e05b8a ee_hs245c2c51g0s010vfi.inp 3,984 11-18-2019 14:44 755dba4f ee_hs245c2c51g0s010vfi.out 650,353 11-19-2019 18:45 3e589627 ee_hs245c2c51g0s030vfi.inp 3,984 11-18-2019 14:44 f874c3a8 ee_hs245c2c51g0s030vfi.out 651,185 11-19-2019 18:53 ada12cef ee_hs245c2c51g0s050vfi.inp 3,984 11-18-2019 14:44 65430b92 ee_hs245c2c51g0s050vfi.out 650,183 11-19-2019 19:20 3107afe9 ee_hs245c2c51g0s070vfi.inp 3,984 11-18-2019 14:44 afb83fb2 ee_hs245c2c51g0s070vfi.out 650,193 11-19-2019 19:21 d53dcc28 ee_hs245c2c51g0s090vfi.inp 3,984 11-18-2019 14:44 4abacbad ee_hs245c2c51g0s090vfi.out 650,131 11-19-2019 19:36 b0ccea42 ee_hs245c2c51g0s095vfi.inp 3,984 11-18-2019 14:44 0e71cfde ee_hs245c2c51g0s095vfi.out 649,771 11-19-2019 19:34 5f4040a5 ee_hs245c2c51g0s100vfi.inp 3,984 11-18-2019 14:45 957a41ee ee_hs245c2c51g0s100vfi.out 649,287 11-19-2019 19:44 220509fa
\\v1.2\\ee\\hs325\\ (18) 5,875,265 11-22-2019 12:48 ee_hs325c2c51g0s001vfi.inp 3,934 11-18-2019 12:56 1fa15f70 ee_hs325c2c51g0s001vfi.out 648,209 11-19-2019 13:59 06dfa693 ee_hs325c2c51g0s005vfi.inp 3,934 11-18-2019 12:56 61f25173 ee_hs325c2c51g0s005vfi.out 649,121 11-19-2019 13:48 87df9a68 ee_hs325c2c51g0s010vfi.inp 3,934 11-18-2019 12:56 68fb9e66 ee_hs325c2c51g0s010vfi.out 649,118 11-19-2019 13:33 f4ea7e6f ee_hs325c2c51g0s030vfi.inp 3,934 11-18-2019 12:56 ba3c5a18 ee_hs325c2c51g0s030vfi.out 648,382 11-19-2019 13:42 9ed86304 ee_hs325c2c51g0s050vfi.inp 3,934 11-18-2019 12:56 3017c736 ee_hs325c2c51g0s050vfi.out 649,123 11-19-2019 13:56 1581aa9b ee_hs325c2c51g0s070vfi.inp 3,934 11-18-2019 12:56 27b6ed57 ee_hs325c2c51g0s070vfi.out 648,935 11-19-2019 14:06 2dc7a15a ee_hs325c2c51g0s090vfi.inp 3,934 11-18-2019 12:56 e4985b44 ee_hs325c2c51g0s090vfi.out 648,997 11-19-2019 14:17 debb6cf9 ee_hs325c2c51g0s095vfi.inp 3,934 11-18-2019 12:57 f3d2032c ee_hs325c2c51g0s095vfi.out 648,462 11-19-2019 14:18 884d5894 ee_hs325c2c51g0s100vfi.inp 3,934 11-18-2019 12:57 324ae18d ee_hs325c2c51g0s100vfi.out 649,512 11-19-2019 14:28 7606c2b6
\\v1.2\\ee\\na245\\ (18) 5,887,220 11-22-2019 12:48
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
121 of 190 ee_na245c2c51g0s001vfio.inp 3,983 11-18-2019 11:33 466b60e9 ee_na245c2c51g0s001vfio.out 649,898 11-19-2019 05:48 87345363 ee_na245c2c51g0s005vfio.inp 3,983 11-18-2019 11:33 899206e1 ee_na245c2c51g0s005vfio.out 649,442 11-19-2019 05:40 2e3d1475 ee_na245c2c51g0s010vfio.inp 3,983 11-18-2019 11:33 4d0a7a34 ee_na245c2c51g0s010vfio.out 650,281 11-19-2019 05:55 8d9ae33d ee_na245c2c51g0s030vfio.inp 3,983 11-18-2019 11:34 e7df1abb ee_na245c2c51g0s030vfio.out 650,078 11-19-2019 06:34 06459afc ee_na245c2c51g0s050vfio.inp 3,983 11-18-2019 11:34 3b217a5e ee_na245c2c51g0s050vfio.out 651,440 11-19-2019 06:49 dd066486 ee_na245c2c51g0s070vfio.inp 3,983 11-18-2019 11:34 683df24f ee_na245c2c51g0s070vfio.out 648,966 11-19-2019 06:59 47d304d4 ee_na245c2c51g0s090vfio.inp 3,983 11-18-2019 11:34 b9a780e2 ee_na245c2c51g0s090vfio.out 650,110 11-19-2019 07:08 29f7565f ee_na245c2c51g0s095vfio.inp 3,983 11-18-2019 11:34 965fd397 ee_na245c2c51g0s095vfio.out 650,685 11-19-2019 06:52 63e8a4cc ee_na245c2c51g0s100vfio.inp 3,983 11-18-2019 11:34 bef45438 ee_na245c2c51g0s100vfio.out 650,473 11-19-2019 07:17 2424c356
\\v1.2\\ee\\na325\\ (18) 5,879,001 11-22-2019 12:48 ee_na325c2c51g0s001vfio.inp 3,933 11-18-2019 10:30 e230d53a ee_na325c2c51g0s001vfio.out 649,229 11-18-2019 21:52 0444a631 ee_na325c2c51g0s005vfio.inp 3,933 11-18-2019 10:30 bf379b72 ee_na325c2c51g0s005vfio.out 649,808 11-18-2019 21:42 bf496a6e ee_na325c2c51g0s010vfio.inp 3,933 11-18-2019 10:30 094a42af ee_na325c2c51g0s010vfio.out 649,013 11-18-2019 22:00 fa185440 ee_na325c2c51g0s030vfio.inp 3,933 11-18-2019 10:30 d93ceb0d ee_na325c2c51g0s030vfio.out 649,529 11-18-2019 22:48 8ae00375 ee_na325c2c51g0s050vfio.inp 3,933 11-18-2019 10:31 0d56054d ee_na325c2c51g0s050vfio.out 649,970 11-18-2019 22:54 3c0dae14 ee_na325c2c51g0s070vfio.inp 3,933 11-18-2019 10:31 602ac362 ee_na325c2c51g0s070vfio.out 648,821 11-18-2019 23:04 7e8fc0ba ee_na325c2c51g0s090vfio.inp 3,933 11-18-2019 10:31 53c683e5 ee_na325c2c51g0s090vfio.out 648,914 11-18-2019 23:08 296bf2b0 ee_na325c2c51g0s095vfio.inp 3,933 11-18-2019 10:31 aba7cf2c ee_na325c2c51g0s095vfio.out 649,367 11-18-2019 23:10 c6acba41 ee_na325c2c51g0s100vfio.inp 3,933 11-18-2019 10:31 0e376774 ee_na325c2c51g0s100vfio.out 648,953 11-18-2019 23:17 aaf3a0ed
\\v1.2\\ee\\ns245\\ (18) 5,885,578 11-22-2019 12:48 ee_ns245c2c51g0s001vfi.inp 3,984 11-18-2019 17:16 9487065f ee_ns245c2c51g0s001vfi.out 649,595 11-20-2019 05:34 f5da852d ee_ns245c2c51g0s005vfi.inp 3,984 11-18-2019 17:16 d19f1831 ee_ns245c2c51g0s005vfi.out 650,280 11-20-2019 05:21 de33afb9 ee_ns245c2c51g0s010vfi.inp 3,984 11-18-2019 17:16 c5a61c91 ee_ns245c2c51g0s010vfi.out 649,972 11-20-2019 05:11 d0bcfce2 ee_ns245c2c51g0s030vfi.inp 3,984 11-18-2019 17:16 488f6576 ee_ns245c2c51g0s030vfi.out 649,480 11-20-2019 05:27 4e1cceb9 ee_ns245c2c51g0s050vfi.inp 3,984 11-18-2019 17:16 d5b8ad4c ee_ns245c2c51g0s050vfi.out 650,581 11-20-2019 05:39 b6b7e820 ee_ns245c2c51g0s070vfi.inp 3,984 11-18-2019 17:16 1f43996c ee_ns245c2c51g0s070vfi.out 650,693 11-20-2019 05:52 0cb84956 ee_ns245c2c51g0s090vfi.inp 3,984 11-18-2019 17:16 fa416d73 ee_ns245c2c51g0s090vfi.out 649,226 11-20-2019 05:37 795ebc3a ee_ns245c2c51g0s095vfi.inp 3,984 11-18-2019 17:16 be8a6900 ee_ns245c2c51g0s095vfi.out 649,888 11-20-2019 05:39 0e38337d ee_ns245c2c51g0s100vfi.inp 3,984 11-18-2019 17:17 2581e730 ee_ns245c2c51g0s100vfi.out 650,007 11-20-2019 05:58 12fd4498
\\v1.2\\ee\\ns325\\ (18) 5,877,349 11-22-2019 12:48 ee_ns325c2c51g0s001vfi.inp 3,934 11-18-2019 16:11 cbae20ac ee_ns325c2c51g0s001vfi.out 649,059 11-20-2019 00:28 f432a2c9 ee_ns325c2c51g0s005vfi.inp 3,934 11-18-2019 16:11 b5fd2eaf ee_ns325c2c51g0s005vfi.out 650,129 11-20-2019 00:17 cda39291 ee_ns325c2c51g0s010vfi.inp 3,934 11-18-2019 16:11 bcf4e1ba ee_ns325c2c51g0s010vfi.out 648,723 11-19-2019 23:58 a1493749 ee_ns325c2c51g0s030vfi.inp 3,934 11-18-2019 16:11 6e3325c4 ee_ns325c2c51g0s030vfi.out 649,261 11-20-2019 00:22 ee87c4d7 ee_ns325c2c51g0s050vfi.inp 3,934 11-18-2019 16:11 e418b8ea ee_ns325c2c51g0s050vfi.out 649,102 11-20-2019 00:36 739eb491 ee_ns325c2c51g0s070vfi.inp 3,934 11-18-2019 16:11 f3b9928b ee_ns325c2c51g0s070vfi.out 649,103 11-20-2019 00:40 f1a92270 ee_ns325c2c51g0s090vfi.inp 3,934 11-18-2019 16:11 30972498 ee_ns325c2c51g0s090vfi.out 648,823 11-20-2019 00:47 ef3697c1 ee_ns325c2c51g0s095vfi.inp 3,934 11-18-2019 16:12 27dd7cf0 ee_ns325c2c51g0s095vfi.out 649,262 11-20-2019 00:51 7f736b8f ee_ns325c2c51g0s100vfi.inp 3,934 11-18-2019 16:12 e6459e51 ee_ns325c2c51g0s100vfi.out 648,481 11-20-2019 00:59 6c823fe5
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
122 of 190
\\v1.2\\ef\\ (0) 41,787,911 11-18-2019 17:17
\\v1.2\\ef\\ha245\\ (18) 5,886,120 11-22-2019 12:48 ef_ha245c2c51g0s001vfio.inp 3,957 11-18-2019 02:19 3ab76b33 ef_ha245c2c51g0s001vfio.out 649,807 11-18-2019 14:40 32f9eb99 ef_ha245c2c51g0s005vfio.inp 3,957 11-18-2019 02:20 35e40689 ef_ha245c2c51g0s005vfio.out 650,321 11-18-2019 14:22 ef331018 ef_ha245c2c51g0s010vfio.inp 3,957 11-18-2019 02:20 d757d718 ef_ha245c2c51g0s010vfio.out 650,136 11-18-2019 14:33 9b20e076 ef_ha245c2c51g0s030vfio.inp 3,957 11-18-2019 02:20 f6be7692 ef_ha245c2c51g0s030vfio.out 650,221 11-18-2019 14:59 6251f7d5 ef_ha245c2c51g0s050vfio.inp 3,957 11-18-2019 02:20 5d9ca623 ef_ha245c2c51g0s050vfio.out 650,454 11-18-2019 15:21 ff8d9771 ef_ha245c2c51g0s070vfio.inp 3,957 11-18-2019 02:20 4d31f9e6 ef_ha245c2c51g0s070vfio.out 649,746 11-18-2019 15:34 ca3d91b3 ef_ha245c2c51g0s090vfio.inp 3,957 11-18-2019 02:20 1bfdccc2 ef_ha245c2c51g0s090vfio.out 649,882 11-18-2019 15:43 1e0157f5 ef_ha245c2c51g0s095vfio.inp 3,957 11-18-2019 02:20 599aae25 ef_ha245c2c51g0s095vfio.out 649,148 11-18-2019 15:46 7ddf185c ef_ha245c2c51g0s100vfio.inp 3,957 11-18-2019 02:20 5a2fb383 ef_ha245c2c51g0s100vfio.out 650,792 11-18-2019 15:51 b2a1251b
\\v1.2\\ef\\ha325\\ (18) 5,875,159 11-22-2019 12:48 ef_ha325c2c51g0s001vfio.inp 3,902 11-18-2019 00:26 7918cc20 ef_ha325c2c51g0s001vfio.out 649,548 11-18-2019 03:57 c852d7e7 ef_ha325c2c51g0s005vfio.inp 3,902 11-18-2019 00:26 0e22fa48 ef_ha325c2c51g0s005vfio.out 649,121 11-18-2019 03:52 49a24105 ef_ha325c2c51g0s010vfio.inp 3,902 11-18-2019 00:26 c10aaaae ef_ha325c2c51g0s010vfio.out 648,228 11-18-2019 04:01 c67f1e30 ef_ha325c2c51g0s030vfio.inp 3,902 11-18-2019 00:26 dd4654b3 ef_ha325c2c51g0s030vfio.out 649,777 11-18-2019 04:34 8f9b525c ef_ha325c2c51g0s050vfio.inp 3,902 11-18-2019 00:26 4ed39eb9 ef_ha325c2c51g0s050vfio.out 649,250 11-18-2019 05:00 4b462580 ef_ha325c2c51g0s070vfio.inp 3,902 11-18-2019 00:26 f5f1ccd5 ef_ha325c2c51g0s070vfio.out 649,379 11-18-2019 04:57 18414636 ef_ha325c2c51g0s090vfio.inp 3,902 11-18-2019 00:26 9ca75de6 ef_ha325c2c51g0s090vfio.out 647,849 11-18-2019 05:33 3da92dec ef_ha325c2c51g0s095vfio.inp 3,902 11-18-2019 00:26 14bf270b ef_ha325c2c51g0s095vfio.out 648,534 11-18-2019 05:18 38a72582 ef_ha325c2c51g0s100vfio.inp 3,902 11-18-2019 00:26 513c3f32 ef_ha325c2c51g0s100vfio.out 648,355 11-18-2019 05:43 9d111a38
\\v1.2\\ef\\hs245\\ (18) 4,570,079 11-22-2019 12:48 ef_hs245c2c51g0s001vfi.inp 3,985 11-18-2019 14:45 1cecd9ec ef_hs245c2c51g0s001vfi.out 504,054 11-19-2019 19:13 2a9fd9da ef_hs245c2c51g0s005vfi.inp 3,985 11-18-2019 14:45 8aef1068 ef_hs245c2c51g0s005vfi.out 503,253 11-19-2019 19:02 35b9b3ec ef_hs245c2c51g0s010vfi.inp 3,985 11-18-2019 14:45 6f825378 ef_hs245c2c51g0s010vfi.out 503,683 11-19-2019 18:50 0e9bada9 ef_hs245c2c51g0s030vfi.inp 3,985 11-18-2019 14:45 3b3d8c29 ef_hs245c2c51g0s030vfi.out 505,638 11-19-2019 18:58 3f0d0efe ef_hs245c2c51g0s050vfi.inp 3,985 11-18-2019 14:45 13a84a45 ef_hs245c2c51g0s050vfi.out 503,731 11-19-2019 19:10 893f4223 ef_hs245c2c51g0s070vfi.inp 3,985 11-18-2019 14:45 0542ef72 ef_hs245c2c51g0s070vfi.out 503,576 11-19-2019 19:31 db6445bb ef_hs245c2c51g0s090vfi.inp 3,985 11-18-2019 14:45 07464019 ef_hs245c2c51g0s090vfi.out 503,484 11-19-2019 19:40 c5376105 ef_hs245c2c51g0s095vfi.inp 3,985 11-18-2019 14:45 77c233c4 ef_hs245c2c51g0s095vfi.out 503,403 11-19-2019 19:41 769554df ef_hs245c2c51g0s100vfi.inp 3,985 11-18-2019 14:45 285cdef6 ef_hs245c2c51g0s100vfi.out 503,392 11-19-2019 19:33 7d05b9f3
\\v1.2\\ef\\hs325\\ (18) 4,561,721 11-22-2019 12:48 ef_hs325c2c51g0s001vfi.inp 3,935 11-18-2019 12:57 f589bfa2 ef_hs325c2c51g0s001vfi.out 503,677 11-19-2019 14:10 43f9d6fc ef_hs325c2c51g0s005vfi.inp 3,935 11-18-2019 12:57 eff5ad9c ef_hs325c2c51g0s005vfi.out 502,940 11-19-2019 13:49 7fe01537 ef_hs325c2c51g0s010vfi.inp 3,935 11-18-2019 12:57 5b8b4a84 ef_hs325c2c51g0s010vfi.out 503,355 11-19-2019 13:38 0f9d02c6 ef_hs325c2c51g0s030vfi.inp 3,935 11-18-2019 12:57 a6bd40c2 ef_hs325c2c51g0s030vfi.out 502,669 11-19-2019 13:52 57d0b937 ef_hs325c2c51g0s050vfi.inp 3,935 11-18-2019 12:57 2f2b262a ef_hs325c2c51g0s050vfi.out 502,934 11-19-2019 14:11 9a54571b ef_hs325c2c51g0s070vfi.inp 3,935 11-18-2019 12:57 e984e498 ef_hs325c2c51g0s070vfi.out 502,365 11-19-2019 14:15 7511fc16
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
123 of 190 ef_hs325c2c51g0s090vfi.inp 3,935 11-18-2019 12:57 eccb7b3e ef_hs325c2c51g0s090vfi.out 502,421 11-19-2019 14:25 1bbd7999 ef_hs325c2c51g0s095vfi.inp 3,935 11-18-2019 12:57 b4b712aa ef_hs325c2c51g0s095vfi.out 503,640 11-19-2019 14:26 81edd2c4 ef_hs325c2c51g0s100vfi.inp 3,935 11-18-2019 12:58 a621d108 ef_hs325c2c51g0s100vfi.out 502,305 11-19-2019 14:26 13f829e4
\\v1.2\\ef\\na245\\ (18) 5,885,743 11-22-2019 12:48 ef_na245c2c51g0s001vfio.inp 3,984 11-18-2019 11:34 9f84ad7a ef_na245c2c51g0s001vfio.out 650,461 11-19-2019 05:51 b632de95 ef_na245c2c51g0s005vfio.inp 3,984 11-18-2019 11:34 9e1e853a ef_na245c2c51g0s005vfio.out 650,309 11-19-2019 05:48 43587070 ef_na245c2c51g0s010vfio.inp 3,984 11-18-2019 11:34 e56e9dec ef_na245c2c51g0s010vfio.out 649,653 11-19-2019 06:02 91331653 ef_na245c2c51g0s030vfio.inp 3,984 11-18-2019 11:34 11f545ac ef_na245c2c51g0s030vfio.out 649,975 11-19-2019 06:31 6cd2ac4a ef_na245c2c51g0s050vfio.inp 3,984 11-18-2019 11:35 f419e8d0 ef_na245c2c51g0s050vfio.out 650,361 11-19-2019 06:53 6fffabb0 ef_na245c2c51g0s070vfio.inp 3,984 11-18-2019 11:35 93f41ddc ef_na245c2c51g0s070vfio.out 649,701 11-19-2019 07:00 0df945be ef_na245c2c51g0s090vfio.inp 3,984 11-18-2019 11:35 1e1249d6 ef_na245c2c51g0s090vfio.out 650,507 11-19-2019 07:10 001b1307 ef_na245c2c51g0s095vfio.inp 3,984 11-18-2019 11:35 e39ace91 ef_na245c2c51g0s095vfio.out 649,081 11-19-2019 07:10 e6bbfe70 ef_na245c2c51g0s100vfio.inp 3,984 11-18-2019 11:35 fe27da79 ef_na245c2c51g0s100vfio.out 649,839 11-19-2019 07:13 57bce2f5
\\v1.2\\ef\\na325\\ (18) 5,877,206 11-22-2019 12:48 ef_na325c2c51g0s001vfio.inp 3,934 11-18-2019 10:31 478b33e4 ef_na325c2c51g0s001vfio.out 649,164 11-18-2019 21:59 c6b93e4c ef_na325c2c51g0s005vfio.inp 3,934 11-18-2019 10:31 4057da14 ef_na325c2c51g0s005vfio.out 649,400 11-18-2019 21:43 fd040d6a ef_na325c2c51g0s010vfio.inp 3,934 11-18-2019 10:31 91d62883 ef_na325c2c51g0s010vfio.out 648,923 11-18-2019 22:15 ceb9ae2f ef_na325c2c51g0s030vfio.inp 3,934 11-18-2019 10:31 af376297 ef_na325c2c51g0s030vfio.out 649,471 11-18-2019 22:46 09d85100 ef_na325c2c51g0s050vfio.inp 3,934 11-18-2019 10:31 f4f7ba96 ef_na325c2c51g0s050vfio.out 649,332 11-18-2019 23:21 153e4e43 ef_na325c2c51g0s070vfio.inp 3,934 11-18-2019 10:32 020620a0 ef_na325c2c51g0s070vfio.out 649,140 11-18-2019 23:28 af31f8b1 ef_na325c2c51g0s090vfio.inp 3,934 11-18-2019 10:32 f3b5843d ef_na325c2c51g0s090vfio.out 648,239 11-18-2019 23:06 37aed665 ef_na325c2c51g0s095vfio.inp 3,934 11-18-2019 10:32 f26ee820 ef_na325c2c51g0s095vfio.out 649,045 11-18-2019 23:44 38309619 ef_na325c2c51g0s100vfio.inp 3,934 11-18-2019 10:32 960c8ba2 ef_na325c2c51g0s100vfio.out 649,086 11-18-2019 23:10 49176be0
\\v1.2\\ef\\ns245\\ (18) 4,570,376 11-22-2019 12:48 ef_ns245c2c51g0s001vfi.inp 3,985 11-18-2019 17:17 4fded036 ef_ns245c2c51g0s001vfi.out 504,363 11-20-2019 05:30 a4262cc2 ef_ns245c2c51g0s005vfi.inp 3,985 11-18-2019 17:17 d9dd19b2 ef_ns245c2c51g0s005vfi.out 503,226 11-20-2019 05:23 5d0e56db ef_ns245c2c51g0s010vfi.inp 3,985 11-18-2019 17:17 3cb05aa2 ef_ns245c2c51g0s010vfi.out 503,829 11-20-2019 05:17 a9e604c9 ef_ns245c2c51g0s030vfi.inp 3,985 11-18-2019 17:17 680f85f3 ef_ns245c2c51g0s030vfi.out 504,001 11-20-2019 05:30 fa6e67af ef_ns245c2c51g0s050vfi.inp 3,985 11-18-2019 17:17 409a439f ef_ns245c2c51g0s050vfi.out 504,338 11-20-2019 05:49 a6b2071a ef_ns245c2c51g0s070vfi.inp 3,985 11-18-2019 17:17 5670e6a8 ef_ns245c2c51g0s070vfi.out 503,914 11-20-2019 05:41 020da8bc ef_ns245c2c51g0s090vfi.inp 3,985 11-18-2019 17:17 547449c3 ef_ns245c2c51g0s090vfi.out 503,134 11-20-2019 06:15 0a1822ec ef_ns245c2c51g0s095vfi.inp 3,985 11-18-2019 17:17 24f03a1e ef_ns245c2c51g0s095vfi.out 504,416 11-20-2019 06:07 6a7ef92a ef_ns245c2c51g0s100vfi.inp 3,985 11-18-2019 17:17 7b6ed72c ef_ns245c2c51g0s100vfi.out 503,290 11-20-2019 06:09 624e87bd
\\v1.2\\ef\\ns325\\ (18) 4,561,507 11-22-2019 12:48 ef_ns325c2c51g0s001vfi.inp 3,935 11-18-2019 16:12 48d1238d ef_ns325c2c51g0s001vfi.out 502,976 11-20-2019 00:36 a7f31170 ef_ns325c2c51g0s005vfi.inp 3,935 11-18-2019 16:12 52ad31b3 ef_ns325c2c51g0s005vfi.out 502,387 11-20-2019 00:16 4d3feb23 ef_ns325c2c51g0s010vfi.inp 3,935 11-18-2019 16:12 e6d3d6ab ef_ns325c2c51g0s010vfi.out 502,996 11-20-2019 00:13 630038d8 ef_ns325c2c51g0s030vfi.inp 3,935 11-18-2019 16:12 1be5dced ef_ns325c2c51g0s030vfi.out 503,153 11-20-2019 00:19 93c80045 ef_ns325c2c51g0s050vfi.inp 3,935 11-18-2019 16:12 9273ba05
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
124 of 190 ef_ns325c2c51g0s050vfi.out 503,049 11-20-2019 00:43 7420df15 ef_ns325c2c51g0s070vfi.inp 3,935 11-18-2019 16:12 54dc78b7 ef_ns325c2c51g0s070vfi.out 502,951 11-20-2019 00:46 5108a35f ef_ns325c2c51g0s090vfi.inp 3,935 11-18-2019 16:12 5193e711 ef_ns325c2c51g0s090vfi.out 502,949 11-20-2019 00:56 05100d9a ef_ns325c2c51g0s095vfi.inp 3,935 11-18-2019 16:12 09ef8e85 ef_ns325c2c51g0s095vfi.out 504,062 11-20-2019 00:58 6d9d1496 ef_ns325c2c51g0s100vfi.inp 3,935 11-18-2019 16:13 1b794d27 ef_ns325c2c51g0s100vfi.out 501,569 11-20-2019 01:13 757fb8d7
\\v1.2\\fa\\ (0) 161,483,513 11-18-2019 17:18
\\v1.2\\fa\\ha245\\ (66) 20,115,152 11-18-2019 20:33 fa_ha245a1c52g1s0500hx.inp 4,170 11-18-2019 02:20 896af5b8 fa_ha245a1c52g1s0500hx.out 653,968 11-18-2019 15:52 fa9db669 fa_ha245a1c52g1s0600hx.inp 4,171 11-18-2019 02:21 f4f90a66 fa_ha245a1c52g1s0600hx.out 654,776 11-18-2019 16:04 c7640af2 fa_ha245a1c52g1s0700hx.inp 4,171 11-18-2019 02:21 90ba5e49 fa_ha245a1c52g1s0700hx.out 654,392 11-18-2019 15:52 e7b8b120 fa_ha245a1c52g1s0800hx.inp 4,171 11-18-2019 02:21 7134dd7d fa_ha245a1c52g1s0800hx.out 653,536 11-18-2019 15:51 03fcb1ca fa_ha245a1c52g1s0900hx.inp 4,171 11-18-2019 02:21 7f602ab5 fa_ha245a1c52g1s0900hx.out 654,458 11-18-2019 15:53 2315292b fa_ha245a1c52g1s1000hx.inp 4,175 11-18-2019 02:21 ec92c2f0 fa_ha245a1c52g1s1000hx.out 653,832 11-18-2019 15:58 8528b24d fa_ha245a1c52g1s1100hx.inp 4,175 11-18-2019 02:21 ad2364cb fa_ha245a1c52g1s1100hx.out 654,636 11-18-2019 15:50 222c2a15 fa_ha245a1c52g1s1200hx.inp 4,175 11-18-2019 02:21 0be286d6 fa_ha245a1c52g1s1200hx.out 653,073 11-18-2019 15:59 0c6258ca fa_ha245a1c52g1s1300hx.inp 4,175 11-18-2019 02:21 b9f90a51 fa_ha245a1c52g1s1300hx.out 653,834 11-18-2019 15:55 3e52d832 fa_ha245a1c52g1s1400hx.inp 4,175 11-18-2019 02:21 4f571ec5 fa_ha245a1c52g1s1400hx.out 654,235 11-18-2019 15:59 5ed8efcd fa_ha245a1c52g1s1500hx.inp 4,175 11-18-2019 02:21 2c3d2340 fa_ha245a1c52g1s1500hx.out 654,644 11-18-2019 16:05 17d923b8 fa_ha245a1c52g2s0500hx.inp 4,168 11-18-2019 02:21 eab21801 fa_ha245a1c52g2s0500hx.out 507,773 11-18-2019 16:44 7517e755 fa_ha245a1c52g2s0600hx.inp 4,169 11-18-2019 02:21 ccfe6779 fa_ha245a1c52g2s0600hx.out 507,777 11-18-2019 16:36 6965f7f5 fa_ha245a1c52g2s0700hx.inp 4,169 11-18-2019 02:22 f06fe0f8 fa_ha245a1c52g2s0700hx.out 508,060 11-18-2019 16:36 1029d5b4 fa_ha245a1c52g2s0800hx.inp 4,169 11-18-2019 02:22 4632d810 fa_ha245a1c52g2s0800hx.out 507,347 11-18-2019 16:34 b6abe87a fa_ha245a1c52g2s0900hx.inp 4,169 11-18-2019 02:22 e0416a4a fa_ha245a1c52g2s0900hx.out 507,407 11-18-2019 16:32 44df05d5 fa_ha245a1c52g2s1000hx.inp 4,173 11-18-2019 02:22 78d39526 fa_ha245a1c52g2s1000hx.out 508,360 11-18-2019 16:26 e6a981f6 fa_ha245a1c52g2s1100hx.inp 4,173 11-18-2019 02:22 baef86de fa_ha245a1c52g2s1100hx.out 507,648 11-18-2019 16:24 df7b50bb fa_ha245a1c52g2s1200hx.inp 4,173 11-18-2019 02:22 2460253d fa_ha245a1c52g2s1200hx.out 508,144 11-18-2019 16:32 164d2346 fa_ha245a1c52g2s1300hx.inp 4,173 11-18-2019 02:22 14c01171 fa_ha245a1c52g2s1300hx.out 507,388 11-18-2019 16:29 d719c24c fa_ha245a1c52g2s1400hx.inp 4,173 11-18-2019 02:22 97e9690c fa_ha245a1c52g2s1400hx.out 508,301 11-18-2019 16:25 5d3f193f fa_ha245a1c52g2s1500hx.inp 4,173 11-18-2019 02:22 ca710719 fa_ha245a1c52g2s1500hx.out 508,653 11-18-2019 16:26 c56379bd fa_ha245a1c52g3s0500hx.inp 4,165 11-18-2019 02:22 9a814774 fa_ha245a1c52g3s0500hx.out 654,425 11-18-2019 16:17 1df6bc0e fa_ha245a1c52g3s0600hx.inp 4,166 11-18-2019 02:22 d3f59c21 fa_ha245a1c52g3s0600hx.out 654,076 11-18-2019 16:20 9fe23534 fa_ha245a1c52g3s0700hx.inp 4,166 11-18-2019 02:22 6c088f33 fa_ha245a1c52g3s0700hx.out 653,945 11-18-2019 16:11 ef98a98c fa_ha245a1c52g3s0800hx.inp 4,166 11-18-2019 02:23 61190e2c fa_ha245a1c52g3s0800hx.out 654,800 11-18-2019 16:16 d431c7d2 fa_ha245a1c52g3s0900hx.inp 4,166 11-18-2019 02:23 ab617b74 fa_ha245a1c52g3s0900hx.out 654,152 11-18-2019 16:06 dcef1df1 fa_ha245a1c52g3s1000hx.inp 4,170 11-18-2019 02:23 356efcfb fa_ha245a1c52g3s1000hx.out 653,784 11-18-2019 16:07 4011a416 fa_ha245a1c52g3s1100hx.inp 4,170 11-18-2019 02:23 5c91363a fa_ha245a1c52g3s1100hx.out 654,587 11-18-2019 16:07 b5e6ccec fa_ha245a1c52g3s1200hx.inp 4,170 11-18-2019 02:23 c69f2ebc fa_ha245a1c52g3s1200hx.out 653,596 11-18-2019 16:00 fc1df724 fa_ha245a1c52g3s1300hx.inp 4,170 11-18-2019 02:23 1f46b999 fa_ha245a1c52g3s1300hx.out 653,748 11-18-2019 16:11 a0c5e6f5 fa_ha245a1c52g3s1400hx.inp 4,170 11-18-2019 02:23 436d075d fa_ha245a1c52g3s1400hx.out 653,990 11-18-2019 16:15 9800dddb fa_ha245a1c52g3s1500hx.inp 4,170 11-18-2019 02:23 7ac9c6b5 fa_ha245a1c52g3s1500hx.out 654,172 11-18-2019 16:16 c0ab3f0b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
125 of 190
\\v1.2\\fa\\ha325\\ (66) 20,807,308 11-18-2019 20:33 fa_ha325a1c52g1s0500hx.inp 4,116 11-18-2019 00:26 844cc63d fa_ha325a1c52g1s0500hx.out 652,933 11-18-2019 05:40 ce570312 fa_ha325a1c52g1s0600hx.inp 4,116 11-18-2019 00:26 8b83a51f fa_ha325a1c52g1s0600hx.out 652,990 11-18-2019 05:42 5d101fc4 fa_ha325a1c52g1s0700hx.inp 4,116 11-18-2019 00:27 7880208a fa_ha325a1c52g1s0700hx.out 653,195 11-18-2019 05:47 371979a0 fa_ha325a1c52g1s0800hx.inp 4,116 11-18-2019 00:27 9be6bb57 fa_ha325a1c52g1s0800hx.out 653,010 11-18-2019 05:45 576f6793 fa_ha325a1c52g1s0900hx.inp 4,116 11-18-2019 00:27 a004bb21 fa_ha325a1c52g1s0900hx.out 652,725 11-18-2019 05:55 172c77e8 fa_ha325a1c52g1s1000hx.inp 4,120 11-18-2019 00:27 83d3f5ce fa_ha325a1c52g1s1000hx.out 652,746 11-18-2019 05:53 af569e7a fa_ha325a1c52g1s1100hx.inp 4,120 11-18-2019 00:27 e55c7c3f fa_ha325a1c52g1s1100hx.out 652,549 11-18-2019 06:08 86444603 fa_ha325a1c52g1s1200hx.inp 4,120 11-18-2019 00:27 b3089b09 fa_ha325a1c52g1s1200hx.out 653,527 11-18-2019 06:08 a62b12ba fa_ha325a1c52g1s1300hx.inp 4,120 11-18-2019 00:27 ab240519 fa_ha325a1c52g1s1300hx.out 652,827 11-18-2019 06:14 91978c8e fa_ha325a1c52g1s1400hx.inp 4,120 11-18-2019 00:27 e1caa4a2 fa_ha325a1c52g1s1400hx.out 652,443 11-18-2019 06:13 ea08bfe4 fa_ha325a1c52g1s1500hx.inp 4,120 11-18-2019 00:27 cee9a615 fa_ha325a1c52g1s1500hx.out 653,529 11-18-2019 06:21 9a17354a fa_ha325a1c52g2s0500hx.inp 4,114 11-18-2019 00:27 9235b559 fa_ha325a1c52g2s0500hx.out 506,417 11-18-2019 07:11 b220de6c fa_ha325a1c52g2s0600hx.inp 4,114 11-18-2019 00:27 8d95054b fa_ha325a1c52g2s0600hx.out 507,176 11-18-2019 06:46 dcbd7d7e fa_ha325a1c52g2s0700hx.inp 4,114 11-18-2019 00:27 59726626 fa_ha325a1c52g2s0700hx.out 506,237 11-18-2019 06:54 a407ded8 fa_ha325a1c52g2s0800hx.inp 4,114 11-18-2019 00:28 2da9e66d fa_ha325a1c52g2s0800hx.out 506,500 11-18-2019 06:52 d0544c26 fa_ha325a1c52g2s0900hx.inp 4,114 11-18-2019 00:28 5ee0ceb4 fa_ha325a1c52g2s0900hx.out 507,221 11-18-2019 06:54 b45f2904 fa_ha325a1c52g2s1000hx.inp 4,118 11-18-2019 00:28 f3f0964d fa_ha325a1c52g2s1000hx.out 507,505 11-18-2019 06:50 cf430500 fa_ha325a1c52g2s1100hx.inp 4,118 11-18-2019 00:28 acfc6ecf fa_ha325a1c52g2s1100hx.out 653,749 11-18-2019 06:52 fb639d7c fa_ha325a1c52g2s1200hx.inp 4,118 11-18-2019 00:28 074dccea fa_ha325a1c52g2s1200hx.out 652,781 11-18-2019 06:53 ecfb4ad3 fa_ha325a1c52g2s1300hx.inp 4,118 11-18-2019 00:28 7265f27e fa_ha325a1c52g2s1300hx.out 652,749 11-18-2019 06:47 2150f016 fa_ha325a1c52g2s1400hx.inp 4,118 11-18-2019 00:28 1f97c77a fa_ha325a1c52g2s1400hx.out 653,256 11-18-2019 06:40 0c82e048 fa_ha325a1c52g2s1500hx.inp 4,118 11-18-2019 00:28 b3d46592 fa_ha325a1c52g2s1500hx.out 653,194 11-18-2019 06:42 12f66a3e fa_ha325a1c52g3s0500hx.inp 4,111 11-18-2019 00:28 a39cd33e fa_ha325a1c52g3s0500hx.out 652,626 11-18-2019 06:30 ba0fed16 fa_ha325a1c52g3s0600hx.inp 4,111 11-18-2019 00:28 cefdd45a fa_ha325a1c52g3s0600hx.out 652,023 11-18-2019 06:38 95576659 fa_ha325a1c52g3s0700hx.inp 4,111 11-18-2019 00:28 28e23575 fa_ha325a1c52g3s0700hx.out 653,630 11-18-2019 06:33 c89a1f07 fa_ha325a1c52g3s0800hx.inp 4,111 11-18-2019 00:28 abffa61b fa_ha325a1c52g3s0800hx.out 652,744 11-18-2019 06:31 b10628fd fa_ha325a1c52g3s0900hx.inp 4,111 11-18-2019 00:28 fe88ea3e fa_ha325a1c52g3s0900hx.out 652,952 11-18-2019 06:32 a9204c77 fa_ha325a1c52g3s1000hx.inp 4,115 11-18-2019 00:29 95e0970c fa_ha325a1c52g3s1000hx.out 651,962 11-18-2019 06:32 c1f2475e fa_ha325a1c52g3s1100hx.inp 4,115 11-18-2019 00:29 4030cd66 fa_ha325a1c52g3s1100hx.out 652,743 11-18-2019 06:37 519557ae fa_ha325a1c52g3s1200hx.inp 4,115 11-18-2019 00:29 10c7d956 fa_ha325a1c52g3s1200hx.out 653,633 11-18-2019 06:37 37f1ce1b fa_ha325a1c52g3s1300hx.inp 4,115 11-18-2019 00:29 d5295852 fa_ha325a1c52g3s1300hx.out 653,911 11-18-2019 06:36 5318de46 fa_ha325a1c52g3s1400hx.inp 4,115 11-18-2019 00:29 32d4ebfc fa_ha325a1c52g3s1400hx.out 653,044 11-18-2019 06:47 40b8c9f5 fa_ha325a1c52g3s1500hx.inp 4,115 11-18-2019 00:29 ca90bcaa fa_ha325a1c52g3s1500hx.out 652,958 11-18-2019 06:40 2ef53990
\\v1.2\\fa\\hs245\\ (66) 20,111,579 11-20-2019 09:22 fa_hs245a1c52g1s0500hx.inp 4,198 11-18-2019 14:46 b0d31cc8 fa_hs245a1c52g1s0500hx.out 653,281 11-19-2019 20:03 49533236 fa_hs245a1c52g1s0600hx.inp 4,199 11-18-2019 14:46 32c3a8ed fa_hs245a1c52g1s0600hx.out 654,349 11-19-2019 19:50 7f86b697 fa_hs245a1c52g1s0700hx.inp 4,199 11-18-2019 14:46 e71d894b fa_hs245a1c52g1s0700hx.out 654,436 11-19-2019 19:47 f97c2d21 fa_hs245a1c52g1s0800hx.inp 4,199 11-18-2019 14:46 24fb1ea7 fa_hs245a1c52g1s0800hx.out 653,650 11-19-2019 19:52 ecac71d0 fa_hs245a1c52g1s0900hx.inp 4,199 11-18-2019 14:46 1d854e89
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
126 of 190 fa_hs245a1c52g1s0900hx.out 653,698 11-19-2019 19:51 2b70fdb5 fa_hs245a1c52g1s1000hx.inp 4,203 11-18-2019 14:46 e02e008f fa_hs245a1c52g1s1000hx.out 654,469 11-19-2019 19:41 ef7b10c4 fa_hs245a1c52g1s1100hx.inp 4,203 11-18-2019 14:46 a8b05256 fa_hs245a1c52g1s1100hx.out 654,000 11-19-2019 19:54 c394efa6 fa_hs245a1c52g1s1200hx.inp 4,203 11-18-2019 14:46 15e1af9f fa_hs245a1c52g1s1200hx.out 653,944 11-19-2019 19:53 127bb920 fa_hs245a1c52g1s1300hx.inp 4,203 11-18-2019 14:46 57711596 fa_hs245a1c52g1s1300hx.out 654,320 11-19-2019 19:58 557eb8f2 fa_hs245a1c52g1s1400hx.inp 4,203 11-18-2019 14:46 29dcdb05 fa_hs245a1c52g1s1400hx.out 653,950 11-19-2019 19:58 48445b6e fa_hs245a1c52g1s1500hx.inp 4,203 11-18-2019 14:46 03b78dfa fa_hs245a1c52g1s1500hx.out 653,819 11-19-2019 20:01 1f954408 fa_hs245a1c52g2s0500hx.inp 4,196 11-18-2019 14:47 aa10ce86 fa_hs245a1c52g2s0500hx.out 507,914 11-19-2019 20:44 fde4df0f fa_hs245a1c52g2s0600hx.inp 4,197 11-18-2019 14:47 2fe0b36f fa_hs245a1c52g2s0600hx.out 507,437 11-19-2019 20:40 a371b659 fa_hs245a1c52g2s0700hx.inp 4,197 11-18-2019 14:47 baa761c6 fa_hs245a1c52g2s0700hx.out 508,224 11-19-2019 20:36 6a4d28e8 fa_hs245a1c52g2s0800hx.inp 4,197 11-18-2019 14:47 fe4d3c7c fa_hs245a1c52g2s0800hx.out 506,750 11-19-2019 20:34 2c2a7cb3 fa_hs245a1c52g2s0900hx.inp 4,197 11-18-2019 14:47 6d2656b7 fa_hs245a1c52g2s0900hx.out 508,608 11-19-2019 20:29 d0f12211 fa_hs245a1c52g2s1000hx.inp 4,201 11-18-2019 14:47 627faf6c fa_hs245a1c52g2s1000hx.out 507,877 11-19-2019 20:42 ed0c820b fa_hs245a1c52g2s1100hx.inp 4,201 11-18-2019 14:47 be8972a1 fa_hs245a1c52g2s1100hx.out 507,321 11-19-2019 20:31 afab41d5 fa_hs245a1c52g2s1200hx.inp 4,201 11-18-2019 14:47 464232d9 fa_hs245a1c52g2s1200hx.out 508,420 11-19-2019 20:30 a515e7c8 fa_hs245a1c52g2s1300hx.inp 4,201 11-18-2019 14:47 807caa78 fa_hs245a1c52g2s1300hx.out 507,455 11-19-2019 20:34 4572232d fa_hs245a1c52g2s1400hx.inp 4,201 11-18-2019 14:47 0baeac2b fa_hs245a1c52g2s1400hx.out 507,636 11-19-2019 20:32 152fda38 fa_hs245a1c52g2s1500hx.inp 4,201 11-18-2019 14:47 4385f69c fa_hs245a1c52g2s1500hx.out 508,326 11-19-2019 20:43 42ba4d28 fa_hs245a1c52g3s0500hx.inp 4,193 11-18-2019 14:48 5a9bc964 fa_hs245a1c52g3s0500hx.out 653,898 11-19-2019 20:26 0d121adb fa_hs245a1c52g3s0600hx.inp 4,194 11-18-2019 14:48 5718f60a fa_hs245a1c52g3s0600hx.out 654,241 11-19-2019 20:21 5616cc9f fa_hs245a1c52g3s0700hx.inp 4,194 11-18-2019 14:48 07fa2241 fa_hs245a1c52g3s0700hx.out 652,769 11-19-2019 20:16 5e4e0648 fa_hs245a1c52g3s0800hx.inp 4,194 11-18-2019 14:48 879a162a fa_hs245a1c52g3s0800hx.out 653,136 11-19-2019 20:21 5f530f91 fa_hs245a1c52g3s0900hx.inp 4,194 11-18-2019 14:48 7e58c656 fa_hs245a1c52g3s0900hx.out 654,334 11-19-2019 20:14 2523c23c fa_hs245a1c52g3s1000hx.inp 4,198 11-18-2019 14:48 2f33e8b8 fa_hs245a1c52g3s1000hx.out 653,866 11-19-2019 20:21 5c08eb2f fa_hs245a1c52g3s1100hx.inp 4,198 11-18-2019 14:48 cd8fbf3e fa_hs245a1c52g3s1100hx.out 653,802 11-19-2019 20:20 cca338a8 fa_hs245a1c52g3s1200hx.inp 4,198 11-18-2019 14:48 6588ba0c fa_hs245a1c52g3s1200hx.out 654,851 11-19-2019 20:22 8dbe0cad fa_hs245a1c52g3s1300hx.inp 4,198 11-18-2019 14:48 4547d54b fa_hs245a1c52g3s1300hx.out 653,739 11-19-2019 20:15 337058c8 fa_hs245a1c52g3s1400hx.inp 4,198 11-18-2019 14:48 ed783a9f fa_hs245a1c52g3s1400hx.out 653,814 11-19-2019 20:12 48eb3ae6 fa_hs245a1c52g3s1500hx.inp 4,198 11-18-2019 14:48 695046a7 fa_hs245a1c52g3s1500hx.out 654,686 11-19-2019 20:22 2dab28ed
\\v1.2\\fa\\hs325\\ (66) 20,074,734 11-20-2019 09:22 fa_hs325a1c52g1s0500hx.inp 4,149 11-18-2019 12:58 a6346cfc fa_hs325a1c52g1s0500hx.out 653,089 11-19-2019 14:47 e8f57d00 fa_hs325a1c52g1s0600hx.inp 4,149 11-18-2019 12:58 74db620d fa_hs325a1c52g1s0600hx.out 653,122 11-19-2019 14:41 89a16c18 fa_hs325a1c52g1s0700hx.inp 4,149 11-18-2019 12:58 8fdfd1b6 fa_hs325a1c52g1s0700hx.out 652,442 11-19-2019 14:40 144c94ff fa_hs325a1c52g1s0800hx.inp 4,149 11-18-2019 12:58 6ef4b2b9 fa_hs325a1c52g1s0800hx.out 652,943 11-19-2019 14:51 3d845f17 fa_hs325a1c52g1s0900hx.inp 4,149 11-18-2019 12:58 0e3087d4 fa_hs325a1c52g1s0900hx.out 652,908 11-19-2019 14:55 decfb42d fa_hs325a1c52g1s1000hx.inp 4,153 11-18-2019 12:58 9b33f6b0 fa_hs325a1c52g1s1000hx.out 652,155 11-19-2019 14:40 e5b97abe fa_hs325a1c52g1s1100hx.inp 4,153 11-18-2019 12:58 a89918a9 fa_hs325a1c52g1s1100hx.out 652,821 11-19-2019 14:53 b8ab6a27 fa_hs325a1c52g1s1200hx.inp 4,153 11-18-2019 12:58 d1553d73 fa_hs325a1c52g1s1200hx.out 653,097 11-19-2019 14:59 35dd874e fa_hs325a1c52g1s1300hx.inp 4,153 11-18-2019 12:58 7fd57cf3 fa_hs325a1c52g1s1300hx.out 652,501 11-19-2019 14:41 c62b6c55 fa_hs325a1c52g1s1400hx.inp 4,153 11-18-2019 12:59 95399ae6 fa_hs325a1c52g1s1400hx.out 653,679 11-19-2019 15:03 660436a9 fa_hs325a1c52g1s1500hx.inp 4,153 11-18-2019 12:59 0cd3a289
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
127 of 190 fa_hs325a1c52g1s1500hx.out 652,490 11-19-2019 14:49 e558170b fa_hs325a1c52g2s0500hx.inp 4,147 11-18-2019 12:59 11a79b4d fa_hs325a1c52g2s0500hx.out 505,836 11-19-2019 15:35 ff4abb7f fa_hs325a1c52g2s0600hx.inp 4,147 11-18-2019 12:59 4d8081ce fa_hs325a1c52g2s0600hx.out 507,183 11-19-2019 15:28 93b037f5 fa_hs325a1c52g2s0700hx.inp 4,147 11-18-2019 12:59 8377b5a9 fa_hs325a1c52g2s0700hx.out 507,311 11-19-2019 15:34 1b5b3aef fa_hs325a1c52g2s0800hx.inp 4,147 11-18-2019 12:59 71548a7b fa_hs325a1c52g2s0800hx.out 506,292 11-19-2019 15:26 2592944d fa_hs325a1c52g2s0900hx.inp 4,147 11-18-2019 12:59 e91336fa fa_hs325a1c52g2s0900hx.out 506,612 11-19-2019 15:39 8811ac9e fa_hs325a1c52g2s1000hx.inp 4,151 11-18-2019 12:59 76894ebe fa_hs325a1c52g2s1000hx.out 507,032 11-19-2019 15:23 01552c6a fa_hs325a1c52g2s1100hx.inp 4,151 11-18-2019 12:59 8b7c1294 fa_hs325a1c52g2s1100hx.out 506,641 11-19-2019 15:31 8801f7c8 fa_hs325a1c52g2s1200hx.inp 4,151 11-18-2019 12:59 a05e7f2a fa_hs325a1c52g2s1200hx.out 507,439 11-19-2019 15:19 b24097e1 fa_hs325a1c52g2s1300hx.inp 4,151 11-18-2019 12:59 589f84e5 fa_hs325a1c52g2s1300hx.out 506,295 11-19-2019 15:34 ae13ec75 fa_hs325a1c52g2s1400hx.inp 4,151 11-18-2019 12:59 8e85f9c3 fa_hs325a1c52g2s1400hx.out 506,186 11-19-2019 15:22 e8b3cef5 fa_hs325a1c52g2s1500hx.inp 4,151 11-18-2019 13:00 de22a599 fa_hs325a1c52g2s1500hx.out 506,037 11-19-2019 15:34 4cea1116 fa_hs325a1c52g3s0500hx.inp 4,144 11-18-2019 13:00 cf6676b5 fa_hs325a1c52g3s0500hx.out 653,339 11-19-2019 15:23 cb3f2e33 fa_hs325a1c52g3s0600hx.inp 4,144 11-18-2019 13:00 98281884 fa_hs325a1c52g3s0600hx.out 653,193 11-19-2019 15:14 29d09812 fa_hs325a1c52g3s0700hx.inp 4,144 11-18-2019 13:00 4b895183 fa_hs325a1c52g3s0700hx.out 653,006 11-19-2019 15:08 fb2c035e fa_hs325a1c52g3s0800hx.inp 4,144 11-18-2019 13:00 2b4e8388 fa_hs325a1c52g3s0800hx.out 652,681 11-19-2019 15:08 a628c042 fa_hs325a1c52g3s0900hx.inp 4,144 11-18-2019 13:00 50e58905 fa_hs325a1c52g3s0900hx.out 652,621 11-19-2019 15:15 c1cae47a fa_hs325a1c52g3s1000hx.inp 4,148 11-18-2019 13:00 8246d5a5 fa_hs325a1c52g3s1000hx.out 653,314 11-19-2019 15:11 f8b654a7 fa_hs325a1c52g3s1100hx.inp 4,148 11-18-2019 13:00 0ac7309a fa_hs325a1c52g3s1100hx.out 652,137 11-19-2019 15:05 a7947298 fa_hs325a1c52g3s1200hx.inp 4,148 11-18-2019 13:00 564c33d8 fa_hs325a1c52g3s1200hx.out 653,262 11-19-2019 15:23 761d831f fa_hs325a1c52g3s1300hx.inp 4,148 11-18-2019 13:00 3e9de547 fa_hs325a1c52g3s1300hx.out 654,039 11-19-2019 15:09 62bc0504 fa_hs325a1c52g3s1400hx.inp 4,148 11-18-2019 13:00 c267a93c fa_hs325a1c52g3s1400hx.out 652,778 11-19-2019 15:15 d87e3d49 fa_hs325a1c52g3s1500hx.inp 4,148 11-18-2019 13:01 0bd53ef7 fa_hs325a1c52g3s1500hx.out 653,341 11-19-2019 15:13 8bdcf474
\\v1.2\\fa\\na245\\ (66) 20,111,280 11-20-2019 09:22 fa_na245a1c52g1s0500hx.inp 4,197 11-18-2019 11:35 d9d2e598 fa_na245a1c52g1s0500hx.out 653,226 11-19-2019 07:19 1c109b23 fa_na245a1c52g1s0600hx.inp 4,198 11-18-2019 11:35 c90a6faa fa_na245a1c52g1s0600hx.out 653,660 11-19-2019 07:19 139fe4da fa_na245a1c52g1s0700hx.inp 4,198 11-18-2019 11:35 939155f8 fa_na245a1c52g1s0700hx.out 653,276 11-19-2019 07:16 b6701e20 fa_na245a1c52g1s0800hx.inp 4,198 11-18-2019 11:35 cbb8ed23 fa_na245a1c52g1s0800hx.out 654,296 11-19-2019 07:17 850854b9 fa_na245a1c52g1s0900hx.inp 4,198 11-18-2019 11:35 30d1fefb fa_na245a1c52g1s0900hx.out 654,026 11-19-2019 07:20 e01d5a62 fa_na245a1c52g1s1000hx.inp 4,202 11-18-2019 11:36 72a9916b fa_na245a1c52g1s1000hx.out 653,867 11-19-2019 07:06 8f6032f9 fa_na245a1c52g1s1100hx.inp 4,202 11-18-2019 11:36 87f044d4 fa_na245a1c52g1s1100hx.out 653,700 11-19-2019 07:20 37f736b7 fa_na245a1c52g1s1200hx.inp 4,202 11-18-2019 11:36 c5565950 fa_na245a1c52g1s1200hx.out 653,581 11-19-2019 07:19 89961a27 fa_na245a1c52g1s1300hx.inp 4,202 11-18-2019 11:36 9f083f76 fa_na245a1c52g1s1300hx.out 654,010 11-19-2019 07:22 65eb91ed fa_na245a1c52g1s1400hx.inp 4,202 11-18-2019 11:36 7a48aae7 fa_na245a1c52g1s1400hx.out 653,332 11-19-2019 07:25 2e5baaeb fa_na245a1c52g1s1500hx.inp 4,202 11-18-2019 11:36 5a26d755 fa_na245a1c52g1s1500hx.out 654,107 11-19-2019 07:26 9ed4f0d3 fa_na245a1c52g2s0500hx.inp 4,195 11-18-2019 11:36 00f62b72 fa_na245a1c52g2s0500hx.out 507,958 11-19-2019 08:16 6b4c8788 fa_na245a1c52g2s0600hx.inp 4,196 11-18-2019 11:36 be15cf40 fa_na245a1c52g2s0600hx.out 507,826 11-19-2019 08:06 625a62f8 fa_na245a1c52g2s0700hx.inp 4,196 11-18-2019 11:36 fd0f92fe fa_na245a1c52g2s0700hx.out 507,260 11-19-2019 07:55 42be7fdf fa_na245a1c52g2s0800hx.inp 4,196 11-18-2019 11:36 c5a97728 fa_na245a1c52g2s0800hx.out 508,045 11-19-2019 08:11 b3a09535 fa_na245a1c52g2s0900hx.inp 4,196 11-18-2019 11:36 9bf1715e fa_na245a1c52g2s0900hx.out 507,656 11-19-2019 08:13 6b5c4970 fa_na245a1c52g2s1000hx.inp 4,200 11-18-2019 11:36 8dc9c59c
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
128 of 190 fa_na245a1c52g2s1000hx.out 507,754 11-19-2019 07:57 e5586845 fa_na245a1c52g2s1100hx.inp 4,200 11-18-2019 11:37 e14d38ec fa_na245a1c52g2s1100hx.out 507,767 11-19-2019 08:03 925a4cdc fa_na245a1c52g2s1200hx.inp 4,200 11-18-2019 11:37 4992e99c fa_na245a1c52g2s1200hx.out 507,265 11-19-2019 08:04 3c00253c fa_na245a1c52g2s1300hx.inp 4,200 11-18-2019 11:37 2559e0ca fa_na245a1c52g2s1300hx.out 508,413 11-19-2019 08:04 d00fafa5 fa_na245a1c52g2s1400hx.inp 4,200 11-18-2019 11:37 b7d741e1 fa_na245a1c52g2s1400hx.out 507,990 11-19-2019 07:59 ff803e6a fa_na245a1c52g2s1500hx.inp 4,200 11-18-2019 11:37 9ef6ace1 fa_na245a1c52g2s1500hx.out 508,832 11-19-2019 07:57 1ce6b0ab fa_na245a1c52g3s0500hx.inp 4,192 11-18-2019 11:37 5e3e2389 fa_na245a1c52g3s0500hx.out 654,732 11-19-2019 07:33 66cc8c41 fa_na245a1c52g3s0600hx.inp 4,193 11-18-2019 11:37 193a6d6d fa_na245a1c52g3s0600hx.out 653,476 11-19-2019 07:40 3531b997 fa_na245a1c52g3s0700hx.inp 4,193 11-18-2019 11:37 6cc9e996 fa_na245a1c52g3s0700hx.out 653,580 11-19-2019 07:54 59d80f2d fa_na245a1c52g3s0800hx.inp 4,193 11-18-2019 11:37 42b36509 fa_na245a1c52g3s0800hx.out 653,739 11-19-2019 07:37 145e856f fa_na245a1c52g3s0900hx.inp 4,193 11-18-2019 11:37 564d75d6 fa_na245a1c52g3s0900hx.out 653,718 11-19-2019 07:47 2c4c1be4 fa_na245a1c52g3s1000hx.inp 4,197 11-18-2019 11:37 c925857e fa_na245a1c52g3s1000hx.out 653,586 11-19-2019 07:51 579ff085 fa_na245a1c52g3s1100hx.inp 4,197 11-18-2019 11:38 a8381de9 fa_na245a1c52g3s1100hx.out 654,223 11-19-2019 07:52 2e518060 fa_na245a1c52g3s1200hx.inp 4,197 11-18-2019 11:38 7a141d35 fa_na245a1c52g3s1200hx.out 654,323 11-19-2019 07:51 daecf24a fa_na245a1c52g3s1300hx.inp 4,197 11-18-2019 11:38 937339ee fa_na245a1c52g3s1300hx.out 654,636 11-19-2019 07:54 371bc825 fa_na245a1c52g3s1400hx.inp 4,197 11-18-2019 11:38 f9e2c5bd fa_na245a1c52g3s1400hx.out 654,257 11-19-2019 07:41 868c1f77 fa_na245a1c52g3s1500hx.inp 4,197 11-18-2019 11:38 710c9871 fa_na245a1c52g3s1500hx.out 654,637 11-19-2019 07:52 7e13eb40
\\v1.2\\fa\\na325\\ (66) 20,074,229 11-20-2019 09:22 fa_na325a1c52g1s0500hx.inp 4,148 11-18-2019 10:32 18be3658 fa_na325a1c52g1s0500hx.out 653,469 11-18-2019 23:34 022128aa fa_na325a1c52g1s0600hx.inp 4,148 11-18-2019 10:32 8fe72180 fa_na325a1c52g1s0600hx.out 652,842 11-18-2019 23:41 d8a90d87 fa_na325a1c52g1s0700hx.inp 4,148 11-18-2019 10:32 63a91c95 fa_na325a1c52g1s0700hx.out 653,555 11-18-2019 23:45 0b59a435 fa_na325a1c52g1s0800hx.inp 4,148 11-18-2019 10:32 efa40987 fa_na325a1c52g1s0800hx.out 652,141 11-18-2019 23:34 52bcddd3 fa_na325a1c52g1s0900hx.inp 4,148 11-18-2019 10:32 62102ba3 fa_na325a1c52g1s0900hx.out 652,576 11-18-2019 23:33 a0f84fc8 fa_na325a1c52g1s1000hx.inp 4,152 11-18-2019 10:32 258f1d9d fa_na325a1c52g1s1000hx.out 652,885 11-18-2019 23:34 16d07aa6 fa_na325a1c52g1s1100hx.inp 4,152 11-18-2019 10:33 466ecca5 fa_na325a1c52g1s1100hx.out 651,864 11-18-2019 23:33 3274aa40 fa_na325a1c52g1s1200hx.inp 4,152 11-18-2019 10:33 5c135048 fa_na325a1c52g1s1200hx.out 652,764 11-18-2019 23:37 8d1f0b75 fa_na325a1c52g1s1300hx.inp 4,152 11-18-2019 10:33 691e69f5 fa_na325a1c52g1s1300hx.out 652,840 11-18-2019 23:41 fddd9cdb fa_na325a1c52g1s1400hx.inp 4,152 11-18-2019 10:33 35843cfb fa_na325a1c52g1s1400hx.out 653,366 11-18-2019 23:41 f4d443bd fa_na325a1c52g1s1500hx.inp 4,152 11-18-2019 10:33 b7dc0220 fa_na325a1c52g1s1500hx.out 652,951 11-18-2019 23:44 74c82e36 fa_na325a1c52g2s0500hx.inp 4,146 11-18-2019 10:33 861f4b85 fa_na325a1c52g2s0500hx.out 506,848 11-19-2019 00:32 ba3592f1 fa_na325a1c52g2s0600hx.inp 4,146 11-18-2019 10:33 c9d4cafb fa_na325a1c52g2s0600hx.out 506,830 11-19-2019 00:13 9376d0c2 fa_na325a1c52g2s0700hx.inp 4,146 11-18-2019 10:33 f404f29d fa_na325a1c52g2s0700hx.out 506,272 11-19-2019 00:25 ae7f7478 fa_na325a1c52g2s0800hx.inp 4,146 11-18-2019 10:33 c23872fc fa_na325a1c52g2s0800hx.out 506,323 11-19-2019 00:26 8c8bfa70 fa_na325a1c52g2s0900hx.inp 4,146 11-18-2019 10:33 0be18cca fa_na325a1c52g2s0900hx.out 506,290 11-19-2019 00:22 c8c679ef fa_na325a1c52g2s1000hx.inp 4,150 11-18-2019 10:33 af8772c4 fa_na325a1c52g2s1000hx.out 506,479 11-19-2019 00:18 0023bdd5 fa_na325a1c52g2s1100hx.inp 4,150 11-18-2019 10:33 9457aad1 fa_na325a1c52g2s1100hx.out 506,374 11-19-2019 00:19 c8cf2540 fa_na325a1c52g2s1200hx.inp 4,150 11-18-2019 10:34 8b684f1e fa_na325a1c52g2s1200hx.out 507,535 11-19-2019 00:16 40a6c057 fa_na325a1c52g2s1300hx.inp 4,150 11-18-2019 10:34 6f07317d fa_na325a1c52g2s1300hx.out 507,046 11-19-2019 00:21 caa6aad3 fa_na325a1c52g2s1400hx.inp 4,150 11-18-2019 10:34 8e42acae fa_na325a1c52g2s1400hx.out 506,589 11-19-2019 00:18 007a45ea fa_na325a1c52g2s1500hx.inp 4,150 11-18-2019 10:34 fa4a0617 fa_na325a1c52g2s1500hx.out 506,428 11-19-2019 00:27 682f2440 fa_na325a1c52g3s0500hx.inp 4,143 11-18-2019 10:34 3e0b5c86
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
129 of 190 fa_na325a1c52g3s0500hx.out 653,136 11-19-2019 00:10 ef907e8e fa_na325a1c52g3s0600hx.inp 4,143 11-18-2019 10:34 b1a75e58 fa_na325a1c52g3s0600hx.out 653,573 11-19-2019 00:04 de6b8a1b fa_na325a1c52g3s0700hx.inp 4,143 11-18-2019 10:34 5112fa02 fa_na325a1c52g3s0700hx.out 652,372 11-19-2019 00:06 b08dfcf7 fa_na325a1c52g3s0800hx.inp 4,143 11-18-2019 10:34 607e71e9 fa_na325a1c52g3s0800hx.out 652,249 11-19-2019 00:16 47f4cde1 fa_na325a1c52g3s0900hx.inp 4,143 11-18-2019 10:34 619d0a6a fa_na325a1c52g3s0900hx.out 652,945 11-19-2019 00:05 e80e42d2 fa_na325a1c52g3s1000hx.inp 4,147 11-18-2019 10:34 bf253428 fa_na325a1c52g3s1000hx.out 652,373 11-19-2019 00:06 ff935ac5 fa_na325a1c52g3s1100hx.inp 4,147 11-18-2019 10:34 d47fea6a fa_na325a1c52g3s1100hx.out 652,713 11-19-2019 00:06 029885c9 fa_na325a1c52g3s1200hx.inp 4,147 11-18-2019 10:34 60aa059e fa_na325a1c52g3s1200hx.out 653,644 11-19-2019 00:08 2a36a30c fa_na325a1c52g3s1300hx.inp 4,147 11-18-2019 10:35 ad7124cd fa_na325a1c52g3s1300hx.out 652,835 11-18-2019 23:58 cc1579f7 fa_na325a1c52g3s1400hx.inp 4,147 11-18-2019 10:35 16739850 fa_na325a1c52g3s1400hx.out 652,919 11-19-2019 00:12 20c26e8a fa_na325a1c52g3s1500hx.inp 4,147 11-18-2019 10:35 04432162 fa_na325a1c52g3s1500hx.out 654,324 11-19-2019 00:13 3e7c377a
\\v1.2\\fa\\ns245\\ (66) 20,115,103 11-20-2019 09:22 fa_ns245a1c52g1s0500hx.inp 4,198 11-18-2019 17:18 635c9e2f fa_ns245a1c52g1s0500hx.out 653,039 11-20-2019 06:18 e256274d fa_ns245a1c52g1s0600hx.inp 4,199 11-18-2019 17:18 3e975d1b fa_ns245a1c52g1s0600hx.out 654,201 11-20-2019 06:12 0d37dc41 fa_ns245a1c52g1s0700hx.inp 4,199 11-18-2019 17:18 eb497cbd fa_ns245a1c52g1s0700hx.out 653,465 11-20-2019 06:04 7df1bb94 fa_ns245a1c52g1s0800hx.inp 4,199 11-18-2019 17:18 28afeb51 fa_ns245a1c52g1s0800hx.out 654,375 11-20-2019 06:08 fde2ebf1 fa_ns245a1c52g1s0900hx.inp 4,199 11-18-2019 17:18 11d1bb7f fa_ns245a1c52g1s0900hx.out 654,169 11-20-2019 06:03 78bed117 fa_ns245a1c52g1s1000hx.inp 4,203 11-18-2019 17:18 868d5735 fa_ns245a1c52g1s1000hx.out 654,082 11-20-2019 05:45 f1594246 fa_ns245a1c52g1s1100hx.inp 4,203 11-18-2019 17:18 ce1305ec fa_ns245a1c52g1s1100hx.out 653,539 11-20-2019 06:15 91bfe335 fa_ns245a1c52g1s1200hx.inp 4,203 11-18-2019 17:18 7342f825 fa_ns245a1c52g1s1200hx.out 653,536 11-20-2019 05:59 32719a5d fa_ns245a1c52g1s1300hx.inp 4,203 11-18-2019 17:18 31d2422c fa_ns245a1c52g1s1300hx.out 654,526 11-20-2019 06:24 1bf24858 fa_ns245a1c52g1s1400hx.inp 4,203 11-18-2019 17:18 4f7f8cbf fa_ns245a1c52g1s1400hx.out 654,410 11-20-2019 05:52 f1d1679c fa_ns245a1c52g1s1500hx.inp 4,203 11-18-2019 17:18 6514da40 fa_ns245a1c52g1s1500hx.out 654,865 11-20-2019 06:23 8bf71049 fa_ns245a1c52g2s0500hx.inp 4,196 11-18-2019 17:19 51923178 fa_ns245a1c52g2s0500hx.out 509,092 11-20-2019 06:57 f7ef63a5 fa_ns245a1c52g2s0600hx.inp 4,197 11-18-2019 17:19 47f7e324 fa_ns245a1c52g2s0600hx.out 507,407 11-20-2019 06:16 1cbfc0c0 fa_ns245a1c52g2s0700hx.inp 4,197 11-18-2019 17:19 d2b0318d fa_ns245a1c52g2s0700hx.out 508,297 11-20-2019 06:47 8aa3f89d fa_ns245a1c52g2s0800hx.inp 4,197 11-18-2019 17:19 965a6c37 fa_ns245a1c52g2s0800hx.out 506,830 11-20-2019 06:50 4a72eeee fa_ns245a1c52g2s0900hx.inp 4,197 11-18-2019 17:19 053106fc fa_ns245a1c52g2s0900hx.out 506,878 11-20-2019 06:23 90286a63 fa_ns245a1c52g2s1000hx.inp 4,201 11-18-2019 17:19 3a1991c9 fa_ns245a1c52g2s1000hx.out 507,174 11-20-2019 06:44 b63166c1 fa_ns245a1c52g2s1100hx.inp 4,201 11-18-2019 17:19 e6ef4c04 fa_ns245a1c52g2s1100hx.out 507,712 11-20-2019 06:14 b3260252 fa_ns245a1c52g2s1200hx.inp 4,201 11-18-2019 17:19 1e240c7c fa_ns245a1c52g2s1200hx.out 508,575 11-20-2019 06:48 5964a169 fa_ns245a1c52g2s1300hx.inp 4,201 11-18-2019 17:19 d81a94dd fa_ns245a1c52g2s1300hx.out 508,217 11-20-2019 06:59 9e905889 fa_ns245a1c52g2s1400hx.inp 4,201 11-18-2019 17:19 53c8928e fa_ns245a1c52g2s1400hx.out 507,292 11-20-2019 06:43 6524b2ba fa_ns245a1c52g2s1500hx.inp 4,201 11-18-2019 17:19 1be3c839 fa_ns245a1c52g2s1500hx.out 507,474 11-20-2019 06:55 8a52e518 fa_ns245a1c52g3s0500hx.inp 4,193 11-18-2019 17:20 f97ee9af fa_ns245a1c52g3s0500hx.out 654,352 11-20-2019 06:10 fc390dd0 fa_ns245a1c52g3s0600hx.inp 4,194 11-18-2019 17:20 69e405bd fa_ns245a1c52g3s0600hx.out 654,605 11-20-2019 06:08 958687c4 fa_ns245a1c52g3s0700hx.inp 4,194 11-18-2019 17:20 3906d1f6 fa_ns245a1c52g3s0700hx.out 654,007 11-20-2019 06:35 0946ad27 fa_ns245a1c52g3s0800hx.inp 4,194 11-18-2019 17:20 b966e59d fa_ns245a1c52g3s0800hx.out 654,425 11-20-2019 06:32 f4f4f78c fa_ns245a1c52g3s0900hx.inp 4,194 11-18-2019 17:20 40a435e1 fa_ns245a1c52g3s0900hx.out 653,988 11-20-2019 06:40 ba6cbba3 fa_ns245a1c52g3s1000hx.inp 4,198 11-18-2019 17:20 530ba69f fa_ns245a1c52g3s1000hx.out 654,073 11-20-2019 05:58 897dd548 fa_ns245a1c52g3s1100hx.inp 4,198 11-18-2019 17:20 b1b7f119
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
130 of 190 fa_ns245a1c52g3s1100hx.out 653,870 11-20-2019 06:40 27814303 fa_ns245a1c52g3s1200hx.inp 4,198 11-18-2019 17:20 19b0f42b fa_ns245a1c52g3s1200hx.out 654,691 11-20-2019 06:40 e41570e9 fa_ns245a1c52g3s1300hx.inp 4,198 11-18-2019 17:20 397f9b6c fa_ns245a1c52g3s1300hx.out 653,883 11-20-2019 06:44 3edb3063 fa_ns245a1c52g3s1400hx.inp 4,198 11-18-2019 17:20 914074b8 fa_ns245a1c52g3s1400hx.out 654,440 11-20-2019 06:49 a6415869 fa_ns245a1c52g3s1500hx.inp 4,198 11-18-2019 17:20 15680880 fa_ns245a1c52g3s1500hx.out 655,055 11-20-2019 06:44 63a4bf28
\\v1.2\\fa\\ns325\\ (66) 20,074,128 11-20-2019 09:22 fa_ns325a1c52g1s0500hx.inp 4,149 11-18-2019 16:13 1e626a2c fa_ns325a1c52g1s0500hx.out 652,406 11-20-2019 01:26 691f9fd5 fa_ns325a1c52g1s0600hx.inp 4,149 11-18-2019 16:13 cc8d64dd fa_ns325a1c52g1s0600hx.out 651,862 11-20-2019 01:07 da2909cf fa_ns325a1c52g1s0700hx.inp 4,149 11-18-2019 16:13 3789d766 fa_ns325a1c52g1s0700hx.out 652,244 11-20-2019 01:09 34300f6c fa_ns325a1c52g1s0800hx.inp 4,149 11-18-2019 16:13 d6a2b469 fa_ns325a1c52g1s0800hx.out 652,946 11-20-2019 01:17 6e8b09d8 fa_ns325a1c52g1s0900hx.inp 4,149 11-18-2019 16:13 b6668104 fa_ns325a1c52g1s0900hx.out 652,705 11-20-2019 01:11 7ab988f6 fa_ns325a1c52g1s1000hx.inp 4,153 11-18-2019 16:13 ad6d362d fa_ns325a1c52g1s1000hx.out 653,071 11-20-2019 01:27 e3c72881 fa_ns325a1c52g1s1100hx.inp 4,153 11-18-2019 16:13 9ec7d834 fa_ns325a1c52g1s1100hx.out 653,392 11-20-2019 01:14 3467ad5f fa_ns325a1c52g1s1200hx.inp 4,153 11-18-2019 16:13 e70bfdee fa_ns325a1c52g1s1200hx.out 654,244 11-20-2019 01:31 f19ccddb fa_ns325a1c52g1s1300hx.inp 4,153 11-18-2019 16:13 498bbc6e fa_ns325a1c52g1s1300hx.out 653,017 11-20-2019 01:19 a1067c93 fa_ns325a1c52g1s1400hx.inp 4,153 11-18-2019 16:13 a3675a7b fa_ns325a1c52g1s1400hx.out 653,419 11-20-2019 01:23 3b537681 fa_ns325a1c52g1s1500hx.inp 4,153 11-18-2019 16:14 3a8d6214 fa_ns325a1c52g1s1500hx.out 652,506 11-20-2019 01:25 2d09fc0c fa_ns325a1c52g2s0500hx.inp 4,147 11-18-2019 16:14 82ed1c0a fa_ns325a1c52g2s0500hx.out 507,227 11-20-2019 02:06 fb54f94a fa_ns325a1c52g2s0600hx.inp 4,147 11-18-2019 16:14 deca0689 fa_ns325a1c52g2s0600hx.out 506,699 11-20-2019 02:01 1f0a44bb fa_ns325a1c52g2s0700hx.inp 4,147 11-18-2019 16:14 103d32ee fa_ns325a1c52g2s0700hx.out 506,861 11-20-2019 02:14 dbb6adf5 fa_ns325a1c52g2s0800hx.inp 4,147 11-18-2019 16:14 e21e0d3c fa_ns325a1c52g2s0800hx.out 505,809 11-20-2019 02:04 8bd514d6 fa_ns325a1c52g2s0900hx.inp 4,147 11-18-2019 16:14 7a59b1bd fa_ns325a1c52g2s0900hx.out 506,944 11-20-2019 01:52 cf9221f4 fa_ns325a1c52g2s1000hx.inp 4,151 11-18-2019 16:14 aa5a69c6 fa_ns325a1c52g2s1000hx.out 506,841 11-20-2019 02:09 7a30c1be fa_ns325a1c52g2s1100hx.inp 4,151 11-18-2019 16:14 57af35ec fa_ns325a1c52g2s1100hx.out 506,587 11-20-2019 01:52 aeaaf5d0 fa_ns325a1c52g2s1200hx.inp 4,151 11-18-2019 16:14 7c8d5852 fa_ns325a1c52g2s1200hx.out 506,752 11-20-2019 01:51 480c9527 fa_ns325a1c52g2s1300hx.inp 4,151 11-18-2019 16:14 844ca39d fa_ns325a1c52g2s1300hx.out 506,698 11-20-2019 01:52 0b37f5a5 fa_ns325a1c52g2s1400hx.inp 4,151 11-18-2019 16:14 5256debb fa_ns325a1c52g2s1400hx.out 506,866 11-20-2019 02:11 df2f3811 fa_ns325a1c52g2s1500hx.inp 4,151 11-18-2019 16:15 02f182e1 fa_ns325a1c52g2s1500hx.out 506,742 11-20-2019 02:02 9ec75b3c fa_ns325a1c52g3s0500hx.inp 4,144 11-18-2019 16:15 011357a5 fa_ns325a1c52g3s0500hx.out 653,041 11-20-2019 01:46 ed5bcd23 fa_ns325a1c52g3s0600hx.inp 4,144 11-18-2019 16:15 565d3994 fa_ns325a1c52g3s0600hx.out 653,143 11-20-2019 01:41 61ff915f fa_ns325a1c52g3s0700hx.inp 4,144 11-18-2019 16:15 85fc7093 fa_ns325a1c52g3s0700hx.out 651,984 11-20-2019 01:44 00b8aad2 fa_ns325a1c52g3s0800hx.inp 4,144 11-18-2019 16:15 e53ba298 fa_ns325a1c52g3s0800hx.out 653,004 11-20-2019 01:46 ae448b10 fa_ns325a1c52g3s0900hx.inp 4,144 11-18-2019 16:15 9e90a815 fa_ns325a1c52g3s0900hx.out 652,229 11-20-2019 01:47 9550e2c4 fa_ns325a1c52g3s1000hx.inp 4,148 11-18-2019 16:15 f1c99395 fa_ns325a1c52g3s1000hx.out 652,956 11-20-2019 01:44 7d5a1d60 fa_ns325a1c52g3s1100hx.inp 4,148 11-18-2019 16:15 794876aa fa_ns325a1c52g3s1100hx.out 652,480 11-20-2019 01:43 15f8f3d2 fa_ns325a1c52g3s1200hx.inp 4,148 11-18-2019 16:15 25c375e8 fa_ns325a1c52g3s1200hx.out 653,608 11-20-2019 01:31 0964f079 fa_ns325a1c52g3s1300hx.inp 4,148 11-18-2019 16:15 4d12a377 fa_ns325a1c52g3s1300hx.out 653,819 11-20-2019 01:57 65f1cac0 fa_ns325a1c52g3s1400hx.inp 4,148 11-18-2019 16:15 b1e8ef0c fa_ns325a1c52g3s1400hx.out 653,008 11-20-2019 01:58 7ce32e0c fa_ns325a1c52g3s1500hx.inp 4,148 11-18-2019 16:15 785a78c7 fa_ns325a1c52g3s1500hx.out 652,106 11-20-2019 01:59 0b6f06d5
\\v1.2\\fb\\ (0) 57,929,148 11-18-2019 17:21
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
131 of 190
\\v1.2\\fb\\ha245\\ (22) 7,247,865 11-18-2019 20:33 fb_ha245c1c52g0s0500hx.inp 4,268 11-18-2019 02:23 f361a77b fb_ha245c1c52g0s0500hx.out 654,491 11-18-2019 16:03 dbd613ca fb_ha245c1c52g0s0600hx.inp 4,269 11-18-2019 02:23 aa03f765 fb_ha245c1c52g0s0600hx.out 654,558 11-18-2019 16:02 04c0e493 fb_ha245c1c52g0s0700hx.inp 4,269 11-18-2019 02:23 e2039198 fb_ha245c1c52g0s0700hx.out 654,008 11-18-2019 16:03 345a34d5 fb_ha245c1c52g0s0800hx.inp 4,269 11-18-2019 02:24 515ba153 fb_ha245c1c52g0s0800hx.out 654,302 11-18-2019 16:00 1b00b7d8 fb_ha245c1c52g0s0900hx.inp 4,269 11-18-2019 02:24 66cac2b2 fb_ha245c1c52g0s0900hx.out 654,303 11-18-2019 16:02 aaaa9319 fb_ha245c1c52g0s1000hx.inp 4,273 11-18-2019 02:24 e8bdfa0b fb_ha245c1c52g0s1000hx.out 654,577 11-18-2019 15:57 a3c02d5c fb_ha245c1c52g0s1100hx.inp 4,273 11-18-2019 02:24 af4f29c1 fb_ha245c1c52g0s1100hx.out 655,030 11-18-2019 16:03 b664f645 fb_ha245c1c52g0s1200hx.inp 4,273 11-18-2019 02:24 10ecd021 fb_ha245c1c52g0s1200hx.out 655,140 11-18-2019 16:02 dd9ac9d3 fb_ha245c1c52g0s1300hx.inp 4,273 11-18-2019 02:24 366406f5 fb_ha245c1c52g0s1300hx.out 654,915 11-18-2019 16:05 131cafd5 fb_ha245c1c52g0s1400hx.inp 4,272 11-18-2019 02:24 b13a1a64 fb_ha245c1c52g0s1400hx.out 654,204 11-18-2019 16:24 76a4fe63 fb_ha245c1c52g0s1500hx.inp 4,272 11-18-2019 02:24 56a7ce09 fb_ha245c1c52g0s1500hx.out 655,357 11-18-2019 16:14 9f65e8dd
\\v1.2\\fb\\ha325\\ (22) 7,235,043 11-18-2019 20:33 fb_ha325c1c52g0s0500hx.inp 4,214 11-18-2019 00:29 70b6d9dd fb_ha325c1c52g0s0500hx.out 652,932 11-18-2019 06:15 dd0443da fb_ha325c1c52g0s0600hx.inp 4,214 11-18-2019 00:29 c38771ba fb_ha325c1c52g0s0600hx.out 653,488 11-18-2019 06:16 942c7436 fb_ha325c1c52g0s0700hx.inp 4,214 11-18-2019 00:29 c00ab40e fb_ha325c1c52g0s0700hx.out 653,481 11-18-2019 06:21 a37ebde4 fb_ha325c1c52g0s0800hx.inp 4,214 11-18-2019 00:29 f80bf088 fb_ha325c1c52g0s0800hx.out 654,266 11-18-2019 06:22 5d2eb7d0 fb_ha325c1c52g0s0900hx.inp 4,213 11-18-2019 00:29 fcc2d3a9 fb_ha325c1c52g0s0900hx.out 653,150 11-18-2019 06:11 4d8931ae fb_ha325c1c52g0s1000hx.inp 4,217 11-18-2019 00:29 1585a129 fb_ha325c1c52g0s1000hx.out 653,452 11-18-2019 06:22 c2deed25 fb_ha325c1c52g0s1100hx.inp 4,217 11-18-2019 00:30 63fa4e94 fb_ha325c1c52g0s1100hx.out 653,923 11-18-2019 06:19 acdc6076 fb_ha325c1c52g0s1200hx.inp 4,217 11-18-2019 00:30 69018a69 fb_ha325c1c52g0s1200hx.out 654,025 11-18-2019 06:19 993e8d39 fb_ha325c1c52g0s1300hx.inp 4,217 11-18-2019 00:30 ab917024 fb_ha325c1c52g0s1300hx.out 652,786 11-18-2019 06:30 63bc685e fb_ha325c1c52g0s1400hx.inp 4,217 11-18-2019 00:30 9ff680f1 fb_ha325c1c52g0s1400hx.out 653,827 11-18-2019 06:28 ff4ca229 fb_ha325c1c52g0s1500hx.inp 4,217 11-18-2019 00:30 0c264f6f fb_ha325c1c52g0s1500hx.out 653,342 11-18-2019 06:29 c23a3e50
\\v1.2\\fb\\hs245\\ (22) 7,248,130 11-20-2019 09:22 fb_hs245c1c52g0s0500hx.inp 4,296 11-18-2019 14:49 de0cf8a6 fb_hs245c1c52g0s0500hx.out 654,342 11-19-2019 20:11 b27fe279 fb_hs245c1c52g0s0600hx.inp 4,297 11-18-2019 14:49 0c746b6d fb_hs245c1c52g0s0600hx.out 654,155 11-19-2019 20:12 ecc391c9 fb_hs245c1c52g0s0700hx.inp 4,297 11-18-2019 14:49 7aafdc32 fb_hs245c1c52g0s0700hx.out 654,529 11-19-2019 20:29 5c5e5725 fb_hs245c1c52g0s0800hx.inp 4,297 11-18-2019 14:49 85d430d3 fb_hs245c1c52g0s0800hx.out 654,905 11-19-2019 20:19 9230ec17 fb_hs245c1c52g0s0900hx.inp 4,297 11-18-2019 14:49 052a31c2 fb_hs245c1c52g0s0900hx.out 654,048 11-19-2019 20:14 7e0986e5 fb_hs245c1c52g0s1000hx.inp 4,301 11-18-2019 14:49 ad3c9a34 fb_hs245c1c52g0s1000hx.out 655,467 11-19-2019 20:20 0502f9f6 fb_hs245c1c52g0s1100hx.inp 4,301 11-18-2019 14:49 738bc931 fb_hs245c1c52g0s1100hx.out 654,764 11-19-2019 20:16 ee6481e1 fb_hs245c1c52g0s1200hx.inp 4,301 11-18-2019 14:49 781ecb95 fb_hs245c1c52g0s1200hx.out 655,163 11-19-2019 20:20 4ca3e32c fb_hs245c1c52g0s1300hx.inp 4,301 11-18-2019 14:49 8312f301 fb_hs245c1c52g0s1300hx.out 653,934 11-19-2019 20:19 08767853 fb_hs245c1c52g0s1400hx.inp 4,300 11-18-2019 14:49 bb74decd fb_hs245c1c52g0s1400hx.out 654,727 11-19-2019 20:26 cd30bfa1 fb_hs245c1c52g0s1500hx.inp 4,300 11-18-2019 14:49 4dd922a4 fb_hs245c1c52g0s1500hx.out 654,808 11-19-2019 20:20 bdd32129
\\v1.2\\fb\\hs325\\ (22) 7,234,494 11-20-2019 09:22 fb_hs325c1c52g0s0500hx.inp 4,247 11-18-2019 13:01 d4c40533 fb_hs325c1c52g0s0500hx.out 653,545 11-19-2019 15:04 15728d16 fb_hs325c1c52g0s0600hx.inp 4,247 11-18-2019 13:01 bf11b49b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
132 of 190 fb_hs325c1c52g0s0600hx.out 653,780 11-19-2019 14:50 ef597839 fb_hs325c1c52g0s0700hx.inp 4,247 11-18-2019 13:01 338a6e94 fb_hs325c1c52g0s0700hx.out 653,132 11-19-2019 14:50 570c701a fb_hs325c1c52g0s0800hx.inp 4,247 11-18-2019 13:01 07bff726 fb_hs325c1c52g0s0800hx.out 653,406 11-19-2019 14:51 fb65cb2f fb_hs325c1c52g0s0900hx.inp 4,246 11-18-2019 13:01 2ac6eaa0 fb_hs325c1c52g0s0900hx.out 653,880 11-19-2019 14:52 85ba3190 fb_hs325c1c52g0s1000hx.inp 4,250 11-18-2019 13:01 dbfaf113 fb_hs325c1c52g0s1000hx.out 653,235 11-19-2019 14:51 7e11c9a2 fb_hs325c1c52g0s1100hx.inp 4,250 11-18-2019 13:01 552a9b53 fb_hs325c1c52g0s1100hx.out 654,009 11-19-2019 14:44 6b121558 fb_hs325c1c52g0s1200hx.inp 4,250 11-18-2019 13:01 f8b0c34a fb_hs325c1c52g0s1200hx.out 653,679 11-19-2019 14:58 706b6667 fb_hs325c1c52g0s1300hx.inp 4,250 11-18-2019 13:01 dc811033 fb_hs325c1c52g0s1300hx.out 652,834 11-19-2019 14:58 b323b51b fb_hs325c1c52g0s1400hx.inp 4,250 11-18-2019 13:01 f3e23a9e fb_hs325c1c52g0s1400hx.out 653,061 11-19-2019 15:02 bb424767 fb_hs325c1c52g0s1500hx.inp 4,250 11-18-2019 13:02 c33976f9 fb_hs325c1c52g0s1500hx.out 653,199 11-19-2019 15:00 689ff860
\\v1.2\\fb\\na245\\ (22) 7,247,231 11-20-2019 09:22 fb_na245c1c52g0s0500hx.inp 4,295 11-18-2019 11:38 37163425 fb_na245c1c52g0s0500hx.out 654,316 11-19-2019 07:47 c1306f99 fb_na245c1c52g0s0600hx.inp 4,296 11-18-2019 11:38 9276a2fb fb_na245c1c52g0s0600hx.out 653,756 11-19-2019 07:33 215fb138 fb_na245c1c52g0s0700hx.inp 4,296 11-18-2019 11:38 7672076f fb_na245c1c52g0s0700hx.out 655,489 11-19-2019 07:20 6870208c fb_na245c1c52g0s0800hx.inp 4,296 11-18-2019 11:38 6471d0ca fb_na245c1c52g0s0800hx.out 654,168 11-19-2019 07:31 3828325b fb_na245c1c52g0s0900hx.inp 4,296 11-18-2019 11:38 f39a5b48 fb_na245c1c52g0s0900hx.out 655,178 11-19-2019 07:26 f3c84e0c fb_na245c1c52g0s1000hx.inp 4,300 11-18-2019 11:39 30cd612d fb_na245c1c52g0s1000hx.out 653,816 11-19-2019 07:38 e16b83db fb_na245c1c52g0s1100hx.inp 4,300 11-18-2019 11:39 9049aea2 fb_na245c1c52g0s1100hx.out 654,394 11-19-2019 07:34 d5260511 fb_na245c1c52g0s1200hx.inp 4,300 11-18-2019 11:39 786654b1 fb_na245c1c52g0s1200hx.out 654,920 11-19-2019 07:37 caf583d5 fb_na245c1c52g0s1300hx.inp 4,300 11-18-2019 11:39 cb175930 fb_na245c1c52g0s1300hx.out 654,207 11-19-2019 07:39 58e09b7c fb_na245c1c52g0s1400hx.inp 4,299 11-18-2019 11:39 4b18e5c3 fb_na245c1c52g0s1400hx.out 655,156 11-19-2019 07:40 fb8f2228 fb_na245c1c52g0s1500hx.inp 4,299 11-18-2019 11:39 f1de7846 fb_na245c1c52g0s1500hx.out 654,554 11-19-2019 07:45 e2695895
\\v1.2\\fb\\na325\\ (22) 7,235,645 11-20-2019 09:22 fb_na325c1c52g0s0500hx.inp 4,246 11-18-2019 10:35 bf791a29 fb_na325c1c52g0s0500hx.out 652,668 11-19-2019 00:04 603d7f3a fb_na325c1c52g0s0600hx.inp 4,246 11-18-2019 10:35 405b00a9 fb_na325c1c52g0s0600hx.out 654,192 11-19-2019 00:01 da961a38 fb_na325c1c52g0s0700hx.inp 4,246 11-18-2019 10:35 44056f76 fb_na325c1c52g0s0700hx.out 653,735 11-18-2019 23:49 fe4b749c fb_na325c1c52g0s0800hx.inp 4,246 11-18-2019 10:35 92671488 fb_na325c1c52g0s0800hx.out 653,695 11-19-2019 00:03 4149edbf fb_na325c1c52g0s0900hx.inp 4,245 11-18-2019 10:35 1aa88ba6 fb_na325c1c52g0s0900hx.out 653,046 11-18-2019 23:56 91232cd1 fb_na325c1c52g0s1000hx.inp 4,249 11-18-2019 10:35 eaa5d99c fb_na325c1c52g0s1000hx.out 653,513 11-18-2019 23:46 c9c2a5c4 fb_na325c1c52g0s1100hx.inp 4,249 11-18-2019 10:35 27412c7a fb_na325c1c52g0s1100hx.out 653,684 11-18-2019 23:57 4f9af449 fb_na325c1c52g0s1200hx.inp 4,249 11-18-2019 10:35 9d9720f5 fb_na325c1c52g0s1200hx.out 653,785 11-18-2019 23:56 2bbbc273 fb_na325c1c52g0s1300hx.inp 4,249 11-18-2019 10:36 09df59ec fb_na325c1c52g0s1300hx.out 653,354 11-18-2019 23:59 fbfbdf77 fb_na325c1c52g0s1400hx.inp 4,249 11-18-2019 10:36 87d2aaa9 fb_na325c1c52g0s1400hx.out 653,297 11-19-2019 00:13 db474ed4 fb_na325c1c52g0s1500hx.inp 4,249 11-18-2019 10:36 7017b568 fb_na325c1c52g0s1500hx.out 653,953 11-18-2019 23:54 18dbd340
\\v1.2\\fb\\ns245\\ (22) 7,248,275 11-20-2019 09:22 fb_ns245c1c52g0s0500hx.inp 4,296 11-18-2019 17:21 0510655e fb_ns245c1c52g0s0500hx.out 654,648 11-20-2019 06:22 4906d334 fb_ns245c1c52g0s0600hx.inp 4,297 11-18-2019 17:21 8d200071 fb_ns245c1c52g0s0600hx.out 654,781 11-20-2019 06:14 5f561943 fb_ns245c1c52g0s0700hx.inp 4,297 11-18-2019 17:21 fbfbb72e fb_ns245c1c52g0s0700hx.out 655,271 11-20-2019 06:12 10bf9bee fb_ns245c1c52g0s0800hx.inp 4,297 11-18-2019 17:21 04805bcf fb_ns245c1c52g0s0800hx.out 653,937 11-20-2019 06:36 45d0c350 fb_ns245c1c52g0s0900hx.inp 4,297 11-18-2019 17:21 847e5ade
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
133 of 190 fb_ns245c1c52g0s0900hx.out 654,268 11-20-2019 06:38 668f3b7d fb_ns245c1c52g0s1000hx.inp 4,301 11-18-2019 17:21 df22afd8 fb_ns245c1c52g0s1000hx.out 654,866 11-20-2019 06:17 d641eb02 fb_ns245c1c52g0s1100hx.inp 4,301 11-18-2019 17:21 0195fcdd fb_ns245c1c52g0s1100hx.out 654,991 11-20-2019 06:13 c23e71a3 fb_ns245c1c52g0s1200hx.inp 4,301 11-18-2019 17:21 0a00fe79 fb_ns245c1c52g0s1200hx.out 654,569 11-20-2019 06:35 240742d7 fb_ns245c1c52g0s1300hx.inp 4,301 11-18-2019 17:21 f10cc6ed fb_ns245c1c52g0s1300hx.out 655,311 11-20-2019 06:44 f7b24a61 fb_ns245c1c52g0s1400hx.inp 4,300 11-18-2019 17:21 9347fb27 fb_ns245c1c52g0s1400hx.out 654,831 11-20-2019 06:07 cfc827e9 fb_ns245c1c52g0s1500hx.inp 4,300 11-18-2019 17:21 65ea074e fb_ns245c1c52g0s1500hx.out 653,514 11-20-2019 06:21 d6659ee5
\\v1.2\\fb\\ns325\\ (22) 7,232,465 11-20-2019 09:22 fb_ns325c1c52g0s0500hx.inp 4,247 11-18-2019 16:16 0a74f4df fb_ns325c1c52g0s0500hx.out 653,503 11-20-2019 01:30 7ac79f02 fb_ns325c1c52g0s0600hx.inp 4,247 11-18-2019 16:16 61a14577 fb_ns325c1c52g0s0600hx.out 652,597 11-20-2019 01:30 8e8130b2 fb_ns325c1c52g0s0700hx.inp 4,247 11-18-2019 16:16 ed3a9f78 fb_ns325c1c52g0s0700hx.out 654,080 11-20-2019 01:30 fd6dbcc0 fb_ns325c1c52g0s0800hx.inp 4,247 11-18-2019 16:16 d90f06ca fb_ns325c1c52g0s0800hx.out 654,129 11-20-2019 01:44 565f5021 fb_ns325c1c52g0s0900hx.inp 4,246 11-18-2019 16:16 10c88f61 fb_ns325c1c52g0s0900hx.out 653,304 11-20-2019 01:32 f7c675a1 fb_ns325c1c52g0s1000hx.inp 4,250 11-18-2019 16:16 898de46f fb_ns325c1c52g0s1000hx.out 653,099 11-20-2019 01:43 8a22484b fb_ns325c1c52g0s1100hx.inp 4,250 11-18-2019 16:16 075d8e2f fb_ns325c1c52g0s1100hx.out 653,225 11-20-2019 01:30 92113db7 fb_ns325c1c52g0s1200hx.inp 4,250 11-18-2019 16:16 aac7d636 fb_ns325c1c52g0s1200hx.out 652,622 11-20-2019 01:44 eef0f0fc fb_ns325c1c52g0s1300hx.inp 4,250 11-18-2019 16:16 8ef6054f fb_ns325c1c52g0s1300hx.out 653,221 11-20-2019 01:48 97691eb0 fb_ns325c1c52g0s1400hx.inp 4,250 11-18-2019 16:16 a1952fe2 fb_ns325c1c52g0s1400hx.out 653,356 11-20-2019 01:46 3e6b9244 fb_ns325c1c52g0s1500hx.inp 4,250 11-18-2019 16:16 914e6385 fb_ns325c1c52g0s1500hx.out 652,595 11-20-2019 01:40 3b6272cf
\\v1.2\\fd\\ (0) 47,396,728 11-18-2019 17:21
\\v1.2\\fd\\ha245\\ (18) 5,929,676 11-22-2019 12:48 fd_ha245c1c52g0s001vfio.inp 4,269 11-18-2019 02:24 72df0685 fd_ha245c1c52g0s001vfio.out 654,337 11-18-2019 14:52 7f92fe87 fd_ha245c1c52g0s005vfio.inp 4,269 11-18-2019 02:24 eaf76383 fd_ha245c1c52g0s005vfio.out 654,312 11-18-2019 14:38 93885fa9 fd_ha245c1c52g0s010vfio.inp 4,269 11-18-2019 02:24 391036f8 fd_ha245c1c52g0s010vfio.out 655,351 11-18-2019 14:48 8442a5d9 fd_ha245c1c52g0s030vfio.inp 4,269 11-18-2019 02:25 b7bd89c3 fd_ha245c1c52g0s030vfio.out 654,346 11-18-2019 15:16 ff952682 fd_ha245c1c52g0s050vfio.inp 4,269 11-18-2019 02:25 181fb4b5 fd_ha245c1c52g0s050vfio.out 654,878 11-18-2019 15:39 ca97a00f fd_ha245c1c52g0s070vfio.inp 4,269 11-18-2019 02:25 76a76224 fd_ha245c1c52g0s070vfio.out 654,650 11-18-2019 15:53 e7329c7e fd_ha245c1c52g0s090vfio.inp 4,269 11-18-2019 02:25 c38145b2 fd_ha245c1c52g0s090vfio.out 654,260 11-18-2019 16:00 7e69a6f9 fd_ha245c1c52g0s095vfio.inp 4,269 11-18-2019 02:25 bc931e9c fd_ha245c1c52g0s095vfio.out 654,817 11-18-2019 16:08 81001e8e fd_ha245c1c52g0s100vfio.inp 4,269 11-18-2019 02:25 66cac2b2 fd_ha245c1c52g0s100vfio.out 654,304 11-18-2019 16:04 037b7b54
\\v1.2\\fd\\ha325\\ (18) 5,918,814 11-22-2019 12:48 fd_ha325c1c52g0s001vfio.inp 4,213 11-18-2019 00:30 2579fbb5 fd_ha325c1c52g0s001vfio.out 653,683 11-18-2019 05:13 1aa1c724 fd_ha325c1c52g0s005vfio.inp 4,213 11-18-2019 00:30 7bd10a19 fd_ha325c1c52g0s005vfio.out 654,060 11-18-2019 04:53 61201665 fd_ha325c1c52g0s010vfio.inp 4,213 11-18-2019 00:30 8525e48c fd_ha325c1c52g0s010vfio.out 653,355 11-18-2019 05:03 eb1a9a0b fd_ha325c1c52g0s030vfio.inp 4,213 11-18-2019 00:30 7e5211b6 fd_ha325c1c52g0s030vfio.out 653,031 11-18-2019 05:26 742c624e fd_ha325c1c52g0s050vfio.inp 4,213 11-18-2019 00:30 ccfb862a fd_ha325c1c52g0s050vfio.out 653,352 11-18-2019 05:53 025cbfb6 fd_ha325c1c52g0s070vfio.inp 4,213 11-18-2019 00:30 68177b7a fd_ha325c1c52g0s070vfio.out 653,180 11-18-2019 06:12 3587b882 fd_ha325c1c52g0s090vfio.inp 4,213 11-18-2019 00:30 28865e3a fd_ha325c1c52g0s090vfio.out 653,580 11-18-2019 06:19 dab91a64 fd_ha325c1c52g0s095vfio.inp 4,213 11-18-2019 00:31 d8526950 fd_ha325c1c52g0s095vfio.out 653,505 11-18-2019 06:06 2f8b0df0
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
134 of 190 fd_ha325c1c52g0s100vfio.inp 4,213 11-18-2019 00:31 fcc2d3a9 fd_ha325c1c52g0s100vfio.out 653,151 11-18-2019 06:19 bd47646d
\\v1.2\\fd\\hs245\\ (18) 5,928,011 11-22-2019 12:48 fd_hs245c1c52g0s001vfi.inp 4,297 11-18-2019 14:50 c31ce908 fd_hs245c1c52g0s001vfi.out 654,136 11-19-2019 20:11 840a3749 fd_hs245c1c52g0s005vfi.inp 4,297 11-18-2019 14:50 40e97e1f fd_hs245c1c52g0s005vfi.out 654,450 11-19-2019 19:42 34870ec3 fd_hs245c1c52g0s010vfi.inp 4,297 11-18-2019 14:50 67a34f8b fd_hs245c1c52g0s010vfi.out 653,737 11-19-2019 19:37 a8bcb34d fd_hs245c1c52g0s030vfi.inp 4,297 11-18-2019 14:50 236cf829 fd_hs245c1c52g0s030vfi.out 654,410 11-19-2019 19:41 0509f883 fd_hs245c1c52g0s050vfi.inp 4,297 11-18-2019 14:50 1557a516 fd_hs245c1c52g0s050vfi.out 654,525 11-19-2019 20:00 d914a147 fd_hs245c1c52g0s070vfi.inp 4,297 11-18-2019 14:50 4a2001ce fd_hs245c1c52g0s070vfi.out 654,555 11-19-2019 20:06 5d2669ab fd_hs245c1c52g0s090vfi.inp 4,297 11-18-2019 14:50 e55ef91d fd_hs245c1c52g0s090vfi.out 655,193 11-19-2019 20:17 33be2065 fd_hs245c1c52g0s095vfi.inp 4,297 11-18-2019 14:50 629cf371 fd_hs245c1c52g0s095vfi.out 654,284 11-19-2019 20:19 80a4ad8f fd_hs245c1c52g0s100vfi.inp 4,297 11-18-2019 14:50 052a31c2 fd_hs245c1c52g0s100vfi.out 654,048 11-19-2019 20:21 d8c8489d
\\v1.2\\fd\\hs325\\ (18) 5,919,885 11-22-2019 12:48 fd_hs325c1c52g0s001vfi.inp 4,246 11-18-2019 13:02 49fbdd1a fd_hs325c1c52g0s001vfi.out 653,840 11-19-2019 14:40 3e3ca51e fd_hs325c1c52g0s005vfi.inp 4,246 11-18-2019 13:02 333bb1d9 fd_hs325c1c52g0s005vfi.out 653,170 11-19-2019 14:24 cfecfe3c fd_hs325c1c52g0s010vfi.inp 4,246 11-18-2019 13:02 c04ec69c fd_hs325c1c52g0s010vfi.out 653,386 11-19-2019 14:15 2243a004 fd_hs325c1c52g0s030vfi.inp 4,246 11-18-2019 13:02 8acb5a06 fd_hs325c1c52g0s030vfi.out 653,521 11-19-2019 14:24 a59da0b9 fd_hs325c1c52g0s050vfi.inp 4,246 11-18-2019 13:02 1f67a35d fd_hs325c1c52g0s050vfi.out 653,956 11-19-2019 14:37 13866bcf fd_hs325c1c52g0s070vfi.inp 4,246 11-18-2019 13:02 23c65cfb fd_hs325c1c52g0s070vfi.out 653,046 11-19-2019 14:47 43105802 fd_hs325c1c52g0s090vfi.inp 4,246 11-18-2019 13:02 95582edd fd_hs325c1c52g0s090vfi.out 654,034 11-19-2019 14:53 dcc66617 fd_hs325c1c52g0s095vfi.inp 4,246 11-18-2019 13:02 f6446149 fd_hs325c1c52g0s095vfi.out 652,838 11-19-2019 15:05 09da900f fd_hs325c1c52g0s100vfi.inp 4,246 11-18-2019 13:02 2ac6eaa0 fd_hs325c1c52g0s100vfi.out 653,880 11-19-2019 15:01 3bf7be1f
\\v1.2\\fd\\na245\\ (18) 5,930,191 11-22-2019 12:48 fd_na245c1c52g0s001vfio.inp 4,296 11-18-2019 11:39 70314647 fd_na245c1c52g0s001vfio.out 654,862 11-19-2019 06:19 a3d9e402 fd_na245c1c52g0s005vfio.inp 4,296 11-18-2019 11:39 5d47fecc fd_na245c1c52g0s005vfio.out 654,541 11-19-2019 06:12 d6ac18e4 fd_na245c1c52g0s010vfio.inp 4,296 11-18-2019 11:39 1a01eb83 fd_na245c1c52g0s010vfio.out 655,128 11-19-2019 06:25 39209b1f fd_na245c1c52g0s030vfio.inp 4,296 11-18-2019 11:39 0beb93e1 fd_na245c1c52g0s030vfio.out 654,562 11-19-2019 07:05 eb523120 fd_na245c1c52g0s050vfio.inp 4,296 11-18-2019 11:39 6707f447 fd_na245c1c52g0s050vfio.out 655,223 11-19-2019 07:19 fc3538ba fd_na245c1c52g0s070vfio.inp 4,296 11-18-2019 11:40 d12061d5 fd_na245c1c52g0s070vfio.out 654,485 11-19-2019 07:37 2d5b7bc9 fd_na245c1c52g0s090vfio.inp 4,296 11-18-2019 11:40 6612b6cc fd_na245c1c52g0s090vfio.out 653,338 11-19-2019 07:33 0e95cf1f fd_na245c1c52g0s095vfio.inp 4,296 11-18-2019 11:40 86389ab8 fd_na245c1c52g0s095vfio.out 654,205 11-19-2019 07:40 f867c5b2 fd_na245c1c52g0s100vfio.inp 4,296 11-18-2019 11:40 f39a5b48 fd_na245c1c52g0s100vfio.out 655,183 11-19-2019 07:38 5cc2ec25
\\v1.2\\fd\\na325\\ (18) 5,919,690 11-22-2019 12:48 fd_na325c1c52g0s001vfio.inp 4,245 11-18-2019 10:36 b5d85133 fd_na325c1c52g0s001vfio.out 653,867 11-18-2019 22:37 3b4d43c9 fd_na325c1c52g0s005vfio.inp 4,245 11-18-2019 10:36 f70f3a22 fd_na325c1c52g0s005vfio.out 653,542 11-18-2019 22:35 f99be219 fd_na325c1c52g0s010vfio.inp 4,245 11-18-2019 10:36 b9ae2602 fd_na325c1c52g0s010vfio.out 654,203 11-18-2019 22:42 91f5e15a fd_na325c1c52g0s030vfio.inp 4,245 11-18-2019 10:36 4ed3b4d5 fd_na325c1c52g0s030vfio.out 654,186 11-18-2019 23:30 6252af7f fd_na325c1c52g0s050vfio.inp 4,245 11-18-2019 10:36 601f5095 fd_na325c1c52g0s050vfio.out 653,273 11-18-2019 23:40 43f340ac fd_na325c1c52g0s070vfio.inp 4,245 11-18-2019 10:36 8615a5d3 fd_na325c1c52g0s070vfio.out 653,612 11-18-2019 23:48 a7a7cca2 fd_na325c1c52g0s090vfio.inp 4,245 11-18-2019 10:36 a84c59e9
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
135 of 190 fd_na325c1c52g0s090vfio.out 652,605 11-18-2019 23:46 b9b90463 fd_na325c1c52g0s095vfio.inp 4,245 11-18-2019 10:36 08c135a9 fd_na325c1c52g0s095vfio.out 653,146 11-18-2019 23:57 4151e42a fd_na325c1c52g0s100vfio.inp 4,245 11-18-2019 10:37 1aa88ba6 fd_na325c1c52g0s100vfio.out 653,051 11-18-2019 23:57 d79c7827
\\v1.2\\fd\\ns245\\ (18) 5,930,178 11-22-2019 12:48 fd_ns245c1c52g0s001vfi.inp 4,297 11-18-2019 17:21 42488214 fd_ns245c1c52g0s001vfi.out 654,353 11-20-2019 06:23 6307af35 fd_ns245c1c52g0s005vfi.inp 4,297 11-18-2019 17:22 c1bd1503 fd_ns245c1c52g0s005vfi.out 655,087 11-20-2019 06:09 6641b552 fd_ns245c1c52g0s010vfi.inp 4,297 11-18-2019 17:22 e6f72497 fd_ns245c1c52g0s010vfi.out 655,804 11-20-2019 05:57 924dfc69 fd_ns245c1c52g0s030vfi.inp 4,297 11-18-2019 17:22 a2389335 fd_ns245c1c52g0s030vfi.out 655,076 11-20-2019 06:12 40065947 fd_ns245c1c52g0s050vfi.inp 4,297 11-18-2019 17:22 9403ce0a fd_ns245c1c52g0s050vfi.out 654,306 11-20-2019 06:23 533fcc26 fd_ns245c1c52g0s070vfi.inp 4,297 11-18-2019 17:22 cb746ad2 fd_ns245c1c52g0s070vfi.out 654,691 11-20-2019 06:41 5a86f872 fd_ns245c1c52g0s090vfi.inp 4,297 11-18-2019 17:22 640a9201 fd_ns245c1c52g0s090vfi.out 654,310 11-20-2019 06:05 8528531d fd_ns245c1c52g0s095vfi.inp 4,297 11-18-2019 17:22 e3c8986d fd_ns245c1c52g0s095vfi.out 653,610 11-20-2019 06:45 9bd2ed76 fd_ns245c1c52g0s100vfi.inp 4,297 11-18-2019 17:22 847e5ade fd_ns245c1c52g0s100vfi.out 654,268 11-20-2019 06:15 9e5b3bda
\\v1.2\\fd\\ns325\\ (18) 5,920,283 11-22-2019 12:48 fd_ns325c1c52g0s001vfi.inp 4,246 11-18-2019 16:17 73f5b8db fd_ns325c1c52g0s001vfi.out 653,904 11-20-2019 01:16 4e7bea91 fd_ns325c1c52g0s005vfi.inp 4,246 11-18-2019 16:17 0935d418 fd_ns325c1c52g0s005vfi.out 654,382 11-20-2019 01:04 9d84e0d0 fd_ns325c1c52g0s010vfi.inp 4,246 11-18-2019 16:17 fa40a35d fd_ns325c1c52g0s010vfi.out 653,644 11-20-2019 00:51 c981abde fd_ns325c1c52g0s030vfi.inp 4,246 11-18-2019 16:17 b0c53fc7 fd_ns325c1c52g0s030vfi.out 653,502 11-20-2019 01:09 4232306e fd_ns325c1c52g0s050vfi.inp 4,246 11-18-2019 16:17 2569c69c fd_ns325c1c52g0s050vfi.out 653,868 11-20-2019 01:24 3e18a22d fd_ns325c1c52g0s070vfi.inp 4,246 11-18-2019 16:17 19c8393a fd_ns325c1c52g0s070vfi.out 652,738 11-20-2019 01:33 4c86fa8b fd_ns325c1c52g0s090vfi.inp 4,246 11-18-2019 16:17 af564b1c fd_ns325c1c52g0s090vfi.out 653,513 11-20-2019 01:42 6312d7ef fd_ns325c1c52g0s095vfi.inp 4,246 11-18-2019 16:17 cc4a0488 fd_ns325c1c52g0s095vfi.out 653,214 11-20-2019 01:33 ec37a2f4 fd_ns325c1c52g0s100vfi.inp 4,246 11-18-2019 16:17 10c88f61 fd_ns325c1c52g0s100vfi.out 653,304 11-20-2019 01:47 d313c24e
\\v1.2\\ff\\ (0) 57,921,177 11-18-2019 17:22
\\v1.2\\ff\\ha245\\ (22) 7,247,474 11-18-2019 20:33 ff_ha245d1c52g0s0500hx.inp 4,276 11-18-2019 02:25 1e0d53d5 ff_ha245d1c52g0s0500hx.out 654,223 11-18-2019 16:07 69c8cea6 ff_ha245d1c52g0s0600hx.inp 4,277 11-18-2019 02:25 88b8559e ff_ha245d1c52g0s0600hx.out 654,723 11-18-2019 16:01 55c090ae ff_ha245d1c52g0s0700hx.inp 4,277 11-18-2019 02:25 68316c48 ff_ha245d1c52g0s0700hx.out 654,758 11-18-2019 15:52 544f6438 ff_ha245d1c52g0s0800hx.inp 4,277 11-18-2019 02:25 9de1ad73 ff_ha245d1c52g0s0800hx.out 654,647 11-18-2019 15:51 1bd010c3 ff_ha245d1c52g0s0900hx.inp 4,277 11-18-2019 02:26 e1b9d3df ff_ha245d1c52g0s0900hx.out 654,214 11-18-2019 16:03 f466a601 ff_ha245d1c52g0s1000hx.inp 4,281 11-18-2019 02:26 04f35f0c ff_ha245d1c52g0s1000hx.out 654,477 11-18-2019 15:52 14eff597 ff_ha245d1c52g0s1100hx.inp 4,281 11-18-2019 02:26 c2862878 ff_ha245d1c52g0s1100hx.out 654,620 11-18-2019 16:11 a2a5efe5 ff_ha245d1c52g0s1200hx.inp 4,281 11-18-2019 02:26 f733d35f ff_ha245d1c52g0s1200hx.out 654,406 11-18-2019 16:04 51fc6586 ff_ha245d1c52g0s1300hx.inp 4,281 11-18-2019 02:26 13a5dbdb ff_ha245d1c52g0s1300hx.out 654,206 11-18-2019 16:12 c392f6b0 ff_ha245d1c52g0s1400hx.inp 4,281 11-18-2019 02:26 57d0f65e ff_ha245d1c52g0s1400hx.out 655,020 11-18-2019 16:06 3efb35fe ff_ha245d1c52g0s1500hx.inp 4,281 11-18-2019 02:26 8e08dbab ff_ha245d1c52g0s1500hx.out 655,110 11-18-2019 16:17 8f45bc53
\\v1.2\\ff\\ha325\\ (22) 7,232,154 11-18-2019 20:33 ff_ha325d1c52g0s0500hx.inp 4,222 11-18-2019 00:31 ba37cef4 ff_ha325d1c52g0s0500hx.out 653,764 11-18-2019 06:24 960a6790 ff_ha325d1c52g0s0600hx.inp 4,222 11-18-2019 00:31 dbcd5b8b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
136 of 190 ff_ha325d1c52g0s0600hx.out 653,273 11-18-2019 06:18 8a4a9bfe ff_ha325d1c52g0s0700hx.inp 4,222 11-18-2019 00:31 868a0fda ff_ha325d1c52g0s0700hx.out 653,043 11-18-2019 06:22 c0c1f474 ff_ha325d1c52g0s0800hx.inp 4,222 11-18-2019 00:31 6aea690a ff_ha325d1c52g0s0800hx.out 653,273 11-18-2019 06:22 fc57a557 ff_ha325d1c52g0s0900hx.inp 4,222 11-18-2019 00:31 4957b2ae ff_ha325d1c52g0s0900hx.out 653,495 11-18-2019 06:17 942e2d6b ff_ha325d1c52g0s1000hx.inp 4,226 11-18-2019 00:31 789b51c0 ff_ha325d1c52g0s1000hx.out 652,461 11-18-2019 06:10 0049dd00 ff_ha325d1c52g0s1100hx.inp 4,226 11-18-2019 00:31 b3dd5129 ff_ha325d1c52g0s1100hx.out 653,217 11-18-2019 06:20 4279d087 ff_ha325d1c52g0s1200hx.inp 4,226 11-18-2019 00:31 ea5b0034 ff_ha325d1c52g0s1200hx.out 653,597 11-18-2019 06:15 c2dc7032 ff_ha325d1c52g0s1300hx.inp 4,226 11-18-2019 00:31 78476b56 ff_ha325d1c52g0s1300hx.out 652,566 11-18-2019 06:26 2447ee92 ff_ha325d1c52g0s1400hx.inp 4,225 11-18-2019 00:31 6afc6bfb ff_ha325d1c52g0s1400hx.out 654,509 11-18-2019 06:22 ddac025a ff_ha325d1c52g0s1500hx.inp 4,225 11-18-2019 00:32 3b5a0ccc ff_ha325d1c52g0s1500hx.out 652,492 11-18-2019 06:32 5b1175d5
\\v1.2\\ff\\hs245\\ (22) 7,246,350 11-20-2019 09:22 ff_hs245d1c52g0s0500hx.inp 4,304 11-18-2019 14:50 6b7eb01d ff_hs245d1c52g0s0500hx.out 653,914 11-19-2019 20:23 dbc4230e ff_hs245d1c52g0s0600hx.inp 4,305 11-18-2019 14:50 518958ce ff_hs245d1c52g0s0600hx.out 654,415 11-19-2019 20:30 9f129206 ff_hs245d1c52g0s0700hx.inp 4,305 11-18-2019 14:51 94636be0 ff_hs245d1c52g0s0700hx.out 654,431 11-19-2019 20:24 f5ac2867 ff_hs245d1c52g0s0800hx.inp 4,305 11-18-2019 14:51 c2b41dab ff_hs245d1c52g0s0800hx.out 654,722 11-19-2019 20:35 3959473f ff_hs245d1c52g0s0900hx.inp 4,305 11-18-2019 14:51 42a44f2c ff_hs245d1c52g0s0900hx.out 654,512 11-19-2019 20:17 2ac9ccf1 ff_hs245d1c52g0s1000hx.inp 4,309 11-18-2019 14:51 86e0c432 ff_hs245d1c52g0s1000hx.out 654,530 11-19-2019 20:22 82cdc2b0 ff_hs245d1c52g0s1100hx.inp 4,309 11-18-2019 14:51 b8d538b2 ff_hs245d1c52g0s1100hx.out 654,351 11-19-2019 20:32 5cb91aeb ff_hs245d1c52g0s1200hx.inp 4,309 11-18-2019 14:51 aa577864 ff_hs245d1c52g0s1200hx.out 653,587 11-19-2019 20:33 fb851fcf ff_hs245d1c52g0s1300hx.inp 4,309 11-18-2019 14:51 5cafc869 ff_hs245d1c52g0s1300hx.out 654,081 11-19-2019 20:27 039475fa ff_hs245d1c52g0s1400hx.inp 4,309 11-18-2019 14:51 14a74803 ff_hs245d1c52g0s1400hx.out 655,423 11-19-2019 20:31 96431f9f ff_hs245d1c52g0s1500hx.inp 4,309 11-18-2019 14:51 04450467 ff_hs245d1c52g0s1500hx.out 655,006 11-19-2019 20:37 a7256b1f
\\v1.2\\ff\\hs325\\ (22) 7,235,277 11-20-2019 09:22 ff_hs325d1c52g0s0500hx.inp 4,255 11-18-2019 13:03 99ef2f4f ff_hs325d1c52g0s0500hx.out 653,590 11-19-2019 15:06 cf3ade11 ff_hs325d1c52g0s0600hx.inp 4,255 11-18-2019 13:03 1ebd21d4 ff_hs325d1c52g0s0600hx.out 653,316 11-19-2019 14:52 c7a7a648 ff_hs325d1c52g0s0700hx.inp 4,255 11-18-2019 13:03 566d4f2b ff_hs325d1c52g0s0700hx.out 653,212 11-19-2019 15:00 f5b1ae2a ff_hs325d1c52g0s0800hx.inp 4,255 11-18-2019 13:03 6db232c5 ff_hs325d1c52g0s0800hx.out 653,982 11-19-2019 15:03 53d5c985 ff_hs325d1c52g0s0900hx.inp 4,255 11-18-2019 13:03 6ab25661 ff_hs325d1c52g0s0900hx.out 653,617 11-19-2019 15:05 e0acc930 ff_hs325d1c52g0s1000hx.inp 4,259 11-18-2019 13:03 b8e6d88a ff_hs325d1c52g0s1000hx.out 653,607 11-19-2019 15:03 6d641d7b ff_hs325d1c52g0s1100hx.inp 4,259 11-18-2019 13:03 8a64040b ff_hs325d1c52g0s1100hx.out 653,352 11-19-2019 14:55 4209c178 ff_hs325d1c52g0s1200hx.inp 4,259 11-18-2019 13:03 e4d533ab ff_hs325d1c52g0s1200hx.out 652,701 11-19-2019 15:18 9aeb3ed5 ff_hs325d1c52g0s1300hx.inp 4,259 11-18-2019 13:03 bae4a230 ff_hs325d1c52g0s1300hx.out 653,759 11-19-2019 15:14 4ea28766 ff_hs325d1c52g0s1400hx.inp 4,258 11-18-2019 13:03 1c638b76 ff_hs325d1c52g0s1400hx.out 653,890 11-19-2019 15:09 1abcfc8b ff_hs325d1c52g0s1500hx.inp 4,258 11-18-2019 13:03 69d24df2 ff_hs325d1c52g0s1500hx.out 653,424 11-19-2019 15:26 6e7e9645
\\v1.2\\ff\\na245\\ (22) 7,246,804 11-20-2019 09:22 ff_na245d1c52g0s0500hx.inp 4,303 11-18-2019 11:40 58e0529d ff_na245d1c52g0s0500hx.out 655,169 11-19-2019 07:42 32a918ce ff_na245d1c52g0s0600hx.inp 4,304 11-18-2019 11:40 066a32a9 ff_na245d1c52g0s0600hx.out 655,138 11-19-2019 07:46 c1129bf7 ff_na245d1c52g0s0700hx.inp 4,304 11-18-2019 11:40 faf40578 ff_na245d1c52g0s0700hx.out 653,709 11-19-2019 08:04 952786e0 ff_na245d1c52g0s0800hx.inp 4,304 11-18-2019 11:40 274ca041 ff_na245d1c52g0s0800hx.out 653,782 11-19-2019 07:45 80c7ba8b ff_na245d1c52g0s0900hx.inp 4,304 11-18-2019 11:40 efa120f4
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
137 of 190 ff_na245d1c52g0s0900hx.out 654,427 11-19-2019 08:04 6dc46b3e ff_na245d1c52g0s1000hx.inp 4,308 11-18-2019 11:40 53ebd7e9 ff_na245d1c52g0s1000hx.out 653,830 11-19-2019 07:52 6bf03734 ff_na245d1c52g0s1100hx.inp 4,308 11-18-2019 11:41 13126fbd ff_na245d1c52g0s1100hx.out 654,456 11-19-2019 08:06 b2bbc80f ff_na245d1c52g0s1200hx.inp 4,308 11-18-2019 11:41 85ea5ad6 ff_na245d1c52g0s1200hx.out 655,183 11-19-2019 07:51 2359ca86 ff_na245d1c52g0s1300hx.inp 4,308 11-18-2019 11:41 fe0518fe ff_na245d1c52g0s1300hx.out 654,706 11-19-2019 07:51 9255eafd ff_na245d1c52g0s1400hx.inp 4,308 11-18-2019 11:41 00bb5f77 ff_na245d1c52g0s1400hx.out 654,517 11-19-2019 07:53 1e98e6df ff_na245d1c52g0s1500hx.inp 4,308 11-18-2019 11:41 ff9d2ed3 ff_na245d1c52g0s1500hx.out 654,520 11-19-2019 07:58 310af895
\\v1.2\\ff\\na325\\ (22) 7,235,542 11-20-2019 09:22 ff_na325d1c52g0s0500hx.inp 4,254 11-18-2019 10:37 c180622e ff_na325d1c52g0s0500hx.out 653,255 11-18-2019 23:57 552d1631 ff_na325d1c52g0s0600hx.inp 4,254 11-18-2019 10:37 86c440dd ff_na325d1c52g0s0600hx.out 653,397 11-19-2019 00:02 05652af7 ff_na325d1c52g0s0700hx.inp 4,254 11-18-2019 10:37 935396d0 ff_na325d1c52g0s0700hx.out 654,251 11-19-2019 00:01 0e4a2e8a ff_na325d1c52g0s0800hx.inp 4,254 11-18-2019 10:37 4729abd4 ff_na325d1c52g0s0800hx.out 654,228 11-19-2019 00:10 ac70cdd5 ff_na325d1c52g0s0900hx.inp 4,254 11-18-2019 10:37 a3c934a4 ff_na325d1c52g0s0900hx.out 653,421 11-19-2019 00:00 c631c3ab ff_na325d1c52g0s1000hx.inp 4,258 11-18-2019 10:37 c75cedaf ff_na325d1c52g0s1000hx.out 653,406 11-19-2019 00:05 a8f0ac8d ff_na325d1c52g0s1100hx.inp 4,258 11-18-2019 10:37 8ca4de7e ff_na325d1c52g0s1100hx.out 652,644 11-19-2019 00:06 1c9c7cae ff_na325d1c52g0s1200hx.inp 4,258 11-18-2019 10:37 1694739b ff_na325d1c52g0s1200hx.out 653,158 11-19-2019 00:09 c6b8f8cc ff_na325d1c52g0s1300hx.inp 4,258 11-18-2019 10:37 34792c72 ff_na325d1c52g0s1300hx.out 653,403 11-19-2019 00:25 b34eb71b ff_na325d1c52g0s1400hx.inp 4,257 11-18-2019 10:37 411886f2 ff_na325d1c52g0s1400hx.out 654,288 11-19-2019 00:26 cd86bb56 ff_na325d1c52g0s1500hx.inp 4,257 11-18-2019 10:37 08d2414f ff_na325d1c52g0s1500hx.out 653,275 11-19-2019 00:18 e263bfdc
\\v1.2\\ff\\ns245\\ (22) 7,245,854 11-20-2019 09:22 ff_ns245d1c52g0s0500hx.inp 4,304 11-18-2019 17:22 21223f1b ff_ns245d1c52g0s0500hx.out 654,750 11-20-2019 06:39 553a885e ff_ns245d1c52g0s0600hx.inp 4,305 11-18-2019 17:22 8a49acdb ff_ns245d1c52g0s0600hx.out 655,010 11-20-2019 06:53 65230382 ff_ns245d1c52g0s0700hx.inp 4,305 11-18-2019 17:23 4fa39ff5 ff_ns245d1c52g0s0700hx.out 654,569 11-20-2019 06:54 101bcb72 ff_ns245d1c52g0s0800hx.inp 4,305 11-18-2019 17:23 1974e9be ff_ns245d1c52g0s0800hx.out 654,764 11-20-2019 06:27 f4c28eba ff_ns245d1c52g0s0900hx.inp 4,305 11-18-2019 17:23 9964bb39 ff_ns245d1c52g0s0900hx.out 654,428 11-20-2019 06:30 e1182785 ff_ns245d1c52g0s1000hx.inp 4,309 11-18-2019 17:23 70f6b500 ff_ns245d1c52g0s1000hx.out 654,381 11-20-2019 06:30 12c52853 ff_ns245d1c52g0s1100hx.inp 4,309 11-18-2019 17:23 4ec34980 ff_ns245d1c52g0s1100hx.out 654,283 11-20-2019 06:54 a6747a2a ff_ns245d1c52g0s1200hx.inp 4,309 11-18-2019 17:23 5c410956 ff_ns245d1c52g0s1200hx.out 653,514 11-20-2019 07:01 ba4475d7 ff_ns245d1c52g0s1300hx.inp 4,309 11-18-2019 17:23 aab9b95b ff_ns245d1c52g0s1300hx.out 654,331 11-20-2019 06:47 a36cac87 ff_ns245d1c52g0s1400hx.inp 4,309 11-18-2019 17:23 e2b13931 ff_ns245d1c52g0s1400hx.out 654,406 11-20-2019 06:56 ba741e78 ff_ns245d1c52g0s1500hx.inp 4,309 11-18-2019 17:23 f2537555 ff_ns245d1c52g0s1500hx.out 654,040 11-20-2019 06:10 05568ace
\\v1.2\\ff\\ns325\\ (22) 7,231,722 11-20-2019 09:22 ff_ns325d1c52g0s0500hx.inp 4,255 11-18-2019 16:17 c16ae7ec ff_ns325d1c52g0s0500hx.out 653,630 11-20-2019 01:48 3caa9a22 ff_ns325d1c52g0s0600hx.inp 4,255 11-18-2019 16:17 4638e977 ff_ns325d1c52g0s0600hx.out 653,358 11-20-2019 01:53 20076df2 ff_ns325d1c52g0s0700hx.inp 4,255 11-18-2019 16:18 0ee88788 ff_ns325d1c52g0s0700hx.out 653,624 11-20-2019 01:50 90c9961f ff_ns325d1c52g0s0800hx.inp 4,255 11-18-2019 16:18 3537fa66 ff_ns325d1c52g0s0800hx.out 653,295 11-20-2019 01:48 68ceb438 ff_ns325d1c52g0s0900hx.inp 4,255 11-18-2019 16:18 32379ec2 ff_ns325d1c52g0s0900hx.out 652,466 11-20-2019 01:48 276d4bdb ff_ns325d1c52g0s1000hx.inp 4,259 11-18-2019 16:18 684fbebc ff_ns325d1c52g0s1000hx.out 653,018 11-20-2019 01:49 6bc01778 ff_ns325d1c52g0s1100hx.inp 4,259 11-18-2019 16:18 5acd623d ff_ns325d1c52g0s1100hx.out 653,393 11-20-2019 01:51 edea7e80 ff_ns325d1c52g0s1200hx.inp 4,259 11-18-2019 16:18 347c559d
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
138 of 190 ff_ns325d1c52g0s1200hx.out 653,383 11-20-2019 01:56 11e0964a ff_ns325d1c52g0s1300hx.inp 4,259 11-18-2019 16:18 6a4dc406 ff_ns325d1c52g0s1300hx.out 652,341 11-20-2019 01:57 4ddc55fd ff_ns325d1c52g0s1400hx.inp 4,258 11-18-2019 16:18 e47206bf ff_ns325d1c52g0s1400hx.out 653,112 11-20-2019 01:59 01b53082 ff_ns325d1c52g0s1500hx.inp 4,258 11-18-2019 16:18 91c3c03b ff_ns325d1c52g0s1500hx.out 653,275 11-20-2019 01:57 79595948
\\v1.2\\fh\\ (0) 47,389,754 11-18-2019 17:23
\\v1.2\\fh\\ha245\\ (18) 5,929,973 11-22-2019 12:48 fh_ha245d1c52g0s001vfio.inp 4,277 11-18-2019 02:26 0632b010 fh_ha245d1c52g0s001vfio.out 655,017 11-18-2019 14:55 2f4e4600 fh_ha245d1c52g0s005vfio.inp 4,277 11-18-2019 02:26 6b357490 fh_ha245d1c52g0s005vfio.out 655,052 11-18-2019 14:41 3c5ffa74 fh_ha245d1c52g0s010vfio.inp 4,277 11-18-2019 02:26 1c624e37 fh_ha245d1c52g0s010vfio.out 654,993 11-18-2019 14:43 c705b040 fh_ha245d1c52g0s030vfio.inp 4,277 11-18-2019 02:26 95383854 fh_ha245d1c52g0s030vfio.out 653,824 11-18-2019 15:26 dcd00b0f fh_ha245d1c52g0s050vfio.inp 4,277 11-18-2019 02:27 88680ffc fh_ha245d1c52g0s050vfio.out 654,288 11-18-2019 15:40 f4bb53f9 fh_ha245d1c52g0s070vfio.inp 4,277 11-18-2019 02:27 b3c4d3cb fh_ha245d1c52g0s070vfio.out 655,402 11-18-2019 16:03 736ce608 fh_ha245d1c52g0s090vfio.inp 4,277 11-18-2019 02:27 98240362 fh_ha245d1c52g0s090vfio.out 654,408 11-18-2019 16:09 c3df6dd2 fh_ha245d1c52g0s095vfio.inp 4,277 11-18-2019 02:27 9eb8fea7 fh_ha245d1c52g0s095vfio.out 654,281 11-18-2019 16:02 6e3c96ab fh_ha245d1c52g0s100vfio.inp 4,277 11-18-2019 02:27 e1b9d3df fh_ha245d1c52g0s100vfio.out 654,215 11-18-2019 16:11 d0498a41
\\v1.2\\fh\\ha325\\ (18) 5,919,966 11-22-2019 12:48 fh_ha325d1c52g0s001vfio.inp 4,222 11-18-2019 00:32 433c8f7a fh_ha325d1c52g0s001vfio.out 652,548 11-18-2019 05:14 84189faa fh_ha325d1c52g0s005vfio.inp 4,222 11-18-2019 00:32 c4561593 fh_ha325d1c52g0s005vfio.out 653,770 11-18-2019 04:58 de8f0d18 fh_ha325d1c52g0s010vfio.inp 4,222 11-18-2019 00:32 0e90a2a1 fh_ha325d1c52g0s010vfio.out 653,298 11-18-2019 05:00 0352411a fh_ha325d1c52g0s030vfio.inp 4,222 11-18-2019 00:32 ff0d3b89 fh_ha325d1c52g0s030vfio.out 653,976 11-18-2019 05:34 62d8230c fh_ha325d1c52g0s050vfio.inp 4,222 11-18-2019 00:32 ed14ae5f fh_ha325d1c52g0s050vfio.out 654,611 11-18-2019 06:02 7a709d1c fh_ha325d1c52g0s070vfio.inp 4,222 11-18-2019 00:32 6c3b7ce0 fh_ha325d1c52g0s070vfio.out 653,291 11-18-2019 06:08 3a54685c fh_ha325d1c52g0s090vfio.inp 4,222 11-18-2019 00:32 0af030bf fh_ha325d1c52g0s090vfio.out 653,197 11-18-2019 06:21 fca7fbcd fh_ha325d1c52g0s095vfio.inp 4,222 11-18-2019 00:32 faa036c0 fh_ha325d1c52g0s095vfio.out 653,780 11-18-2019 06:24 89a5f937 fh_ha325d1c52g0s100vfio.inp 4,222 11-18-2019 00:32 4957b2ae fh_ha325d1c52g0s100vfio.out 653,497 11-18-2019 06:26 3935a953
\\v1.2\\fh\\hs245\\ (18) 5,927,699 11-22-2019 12:48 fh_hs245d1c52g0s001vfi.inp 4,305 11-18-2019 14:51 aa7fbdc0 fh_hs245d1c52g0s001vfi.out 654,426 11-19-2019 20:13 84803106 fh_hs245d1c52g0s005vfi.inp 4,305 11-18-2019 14:52 cecd9490 fh_hs245d1c52g0s005vfi.out 653,036 11-19-2019 19:58 ceb93814 fh_hs245d1c52g0s010vfi.inp 4,305 11-18-2019 14:52 a58059b3 fh_hs245d1c52g0s010vfi.out 654,920 11-19-2019 19:50 3e6c37a2 fh_hs245d1c52g0s030vfi.inp 4,305 11-18-2019 14:52 4d497de6 fh_hs245d1c52g0s030vfi.out 653,808 11-19-2019 20:04 689d142a fh_hs245d1c52g0s050vfi.inp 4,305 11-18-2019 14:52 f975c3d7 fh_hs245d1c52g0s050vfi.out 655,051 11-19-2019 20:12 f249ec33 fh_hs245d1c52g0s070vfi.inp 4,305 11-18-2019 14:52 65d08121 fh_hs245d1c52g0s070vfi.out 654,238 11-19-2019 20:13 f660b422 fh_hs245d1c52g0s090vfi.inp 4,305 11-18-2019 14:52 f1fcf4ec fh_hs245d1c52g0s090vfi.out 653,634 11-19-2019 20:49 2df04300 fh_hs245d1c52g0s095vfi.inp 4,305 11-18-2019 14:52 90f177dd fh_hs245d1c52g0s095vfi.out 655,327 11-19-2019 20:30 f7c4799b fh_hs245d1c52g0s100vfi.inp 4,305 11-18-2019 14:52 42a44f2c fh_hs245d1c52g0s100vfi.out 654,514 11-19-2019 20:35 a48c6b30
\\v1.2\\fh\\hs325\\ (18) 5,918,731 11-22-2019 12:48 fh_hs325d1c52g0s001vfi.inp 4,255 11-18-2019 13:04 4157bed1 fh_hs325d1c52g0s001vfi.out 654,957 11-19-2019 14:43 ebec69fc fh_hs325d1c52g0s005vfi.inp 4,255 11-18-2019 13:04 ba2cdab2 fh_hs325d1c52g0s005vfi.out 653,559 11-19-2019 14:30 daca9377 fh_hs325d1c52g0s010vfi.inp 4,255 11-18-2019 13:04 28d29ac1
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
139 of 190 fh_hs325d1c52g0s010vfi.out 652,619 11-19-2019 14:34 20a587ad fh_hs325d1c52g0s030vfi.inp 4,255 11-18-2019 13:04 2a25833b fh_hs325d1c52g0s030vfi.out 653,363 11-19-2019 14:40 c5202dd6 fh_hs325d1c52g0s050vfi.inp 4,255 11-18-2019 13:04 efcedf0a fh_hs325d1c52g0s050vfi.out 653,182 11-19-2019 14:56 ef23e2bf fh_hs325d1c52g0s070vfi.inp 4,255 11-18-2019 13:04 f6caad2b fh_hs325d1c52g0s070vfi.out 652,445 11-19-2019 14:57 a848f62c fh_hs325d1c52g0s090vfi.inp 4,255 11-18-2019 13:04 28c90f78 fh_hs325d1c52g0s090vfi.out 653,542 11-19-2019 15:06 ccbf3ecd fh_hs325d1c52g0s095vfi.inp 4,255 11-18-2019 13:04 d1b6d6dc fh_hs325d1c52g0s095vfi.out 653,151 11-19-2019 14:59 80a28fca fh_hs325d1c52g0s100vfi.inp 4,255 11-18-2019 13:04 6ab25661 fh_hs325d1c52g0s100vfi.out 653,618 11-19-2019 15:08 14df7b10
\\v1.2\\fh\\na245\\ (18) 5,928,485 11-22-2019 12:48 fh_na245d1c52g0s001vfio.inp 4,304 11-18-2019 11:41 23bfc460 fh_na245d1c52g0s001vfio.out 654,149 11-19-2019 06:33 6ac3bafb fh_na245d1c52g0s005vfio.inp 4,304 11-18-2019 11:41 a2311c8d fh_na245d1c52g0s005vfio.out 654,518 11-19-2019 06:26 ac9ed756 fh_na245d1c52g0s010vfio.inp 4,304 11-18-2019 11:41 662c4d4f fh_na245d1c52g0s010vfio.out 654,809 11-19-2019 06:49 88255495 fh_na245d1c52g0s030vfio.inp 4,304 11-18-2019 11:41 edaef8d1 fh_na245d1c52g0s030vfio.out 654,400 11-19-2019 07:17 f192cdf4 fh_na245d1c52g0s050vfio.inp 4,304 11-18-2019 11:41 eaa1f68b fh_na245d1c52g0s050vfio.out 653,795 11-19-2019 07:39 a8cac0ef fh_na245d1c52g0s070vfio.inp 4,304 11-18-2019 11:42 7fd4d2b5 fh_na245d1c52g0s070vfio.out 654,709 11-19-2019 07:45 ad930726 fh_na245d1c52g0s090vfio.inp 4,304 11-18-2019 11:42 58d6bc5e fh_na245d1c52g0s090vfio.out 654,658 11-19-2019 08:00 1739d6df fh_na245d1c52g0s095vfio.inp 4,304 11-18-2019 11:42 081c7531 fh_na245d1c52g0s095vfio.out 654,277 11-19-2019 07:54 8d22e766 fh_na245d1c52g0s100vfio.inp 4,304 11-18-2019 11:42 efa120f4 fh_na245d1c52g0s100vfio.out 654,434 11-19-2019 07:56 369ac862
\\v1.2\\fh\\na325\\ (18) 5,916,681 11-22-2019 12:48 fh_na325d1c52g0s001vfio.inp 4,254 11-18-2019 10:38 cd7b89fe fh_na325d1c52g0s001vfio.out 653,770 11-18-2019 22:46 abf1b277 fh_na325d1c52g0s005vfio.inp 4,254 11-18-2019 10:38 234efec6 fh_na325d1c52g0s005vfio.out 653,594 11-18-2019 22:38 f8b41852 fh_na325d1c52g0s010vfio.inp 4,254 11-18-2019 10:38 3d120a74 fh_na325d1c52g0s010vfio.out 652,820 11-18-2019 22:47 13a1ed70 fh_na325d1c52g0s030vfio.inp 4,254 11-18-2019 10:38 0e6ac377 fh_na325d1c52g0s030vfio.out 652,722 11-18-2019 23:30 8b4bbf37 fh_na325d1c52g0s050vfio.inp 4,254 11-18-2019 10:38 7fb5c785 fh_na325d1c52g0s050vfio.out 653,171 11-19-2019 00:03 a5393c48 fh_na325d1c52g0s070vfio.inp 4,254 11-18-2019 10:38 d0450d3e fh_na325d1c52g0s070vfio.out 653,215 11-18-2019 23:58 11f6200f fh_na325d1c52g0s090vfio.inp 4,254 11-18-2019 10:38 075ddadb fh_na325d1c52g0s090vfio.out 652,945 11-19-2019 00:15 795d7d2a fh_na325d1c52g0s095vfio.inp 4,254 11-18-2019 10:38 525d9f9a fh_na325d1c52g0s095vfio.out 652,738 11-19-2019 00:29 3308a41b fh_na325d1c52g0s100vfio.inp 4,254 11-18-2019 10:38 a3c934a4 fh_na325d1c52g0s100vfio.out 653,420 11-19-2019 00:15 7443c25d
\\v1.2\\fh\\ns245\\ (18) 5,930,011 11-22-2019 12:48 fh_ns245d1c52g0s001vfi.inp 4,305 11-18-2019 17:23 71bf49d5 fh_ns245d1c52g0s001vfi.out 654,926 11-20-2019 06:06 e31ff077 fh_ns245d1c52g0s005vfi.inp 4,305 11-18-2019 17:23 150d6085 fh_ns245d1c52g0s005vfi.out 655,377 11-20-2019 06:16 c4cb2b7d fh_ns245d1c52g0s010vfi.inp 4,305 11-18-2019 17:24 7e40ada6 fh_ns245d1c52g0s010vfi.out 654,011 11-20-2019 06:01 11020fc8 fh_ns245d1c52g0s030vfi.inp 4,305 11-18-2019 17:24 968989f3 fh_ns245d1c52g0s030vfi.out 655,518 11-20-2019 06:31 33f7253a fh_ns245d1c52g0s050vfi.inp 4,305 11-18-2019 17:24 22b537c2 fh_ns245d1c52g0s050vfi.out 655,108 11-20-2019 06:41 5979e779 fh_ns245d1c52g0s070vfi.inp 4,305 11-18-2019 17:24 be107534 fh_ns245d1c52g0s070vfi.out 654,199 11-20-2019 06:55 69fdaf71 fh_ns245d1c52g0s090vfi.inp 4,305 11-18-2019 17:24 2a3c00f9 fh_ns245d1c52g0s090vfi.out 653,745 11-20-2019 06:59 41657f33 fh_ns245d1c52g0s095vfi.inp 4,305 11-18-2019 17:24 4b3183c8 fh_ns245d1c52g0s095vfi.out 653,953 11-20-2019 06:23 51188a28 fh_ns245d1c52g0s100vfi.inp 4,305 11-18-2019 17:24 9964bb39 fh_ns245d1c52g0s100vfi.out 654,429 11-20-2019 06:55 2a5644f1
\\v1.2\\fh\\ns325\\ (18) 5,918,208 11-22-2019 12:48 fh_ns325d1c52g0s001vfi.inp 4,255 11-18-2019 16:18 19d27672 fh_ns325d1c52g0s001vfi.out 653,946 11-20-2019 01:28 87a542fd
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
140 of 190 fh_ns325d1c52g0s005vfi.inp 4,255 11-18-2019 16:18 e2a91211 fh_ns325d1c52g0s005vfi.out 653,153 11-20-2019 01:12 e4ad6621 fh_ns325d1c52g0s010vfi.inp 4,255 11-18-2019 16:18 70575262 fh_ns325d1c52g0s010vfi.out 653,091 11-20-2019 01:07 1c2c516b fh_ns325d1c52g0s030vfi.inp 4,255 11-18-2019 16:19 72a04b98 fh_ns325d1c52g0s030vfi.out 653,672 11-20-2019 01:32 4de96454 fh_ns325d1c52g0s050vfi.inp 4,255 11-18-2019 16:19 b74b17a9 fh_ns325d1c52g0s050vfi.out 653,322 11-20-2019 01:39 2588aa6a fh_ns325d1c52g0s070vfi.inp 4,255 11-18-2019 16:19 ae4f6588 fh_ns325d1c52g0s070vfi.out 653,313 11-20-2019 01:41 96d3836d fh_ns325d1c52g0s090vfi.inp 4,255 11-18-2019 16:19 704cc7db fh_ns325d1c52g0s090vfi.out 653,974 11-20-2019 01:53 2c64fd56 fh_ns325d1c52g0s095vfi.inp 4,255 11-18-2019 16:19 89331e7f fh_ns325d1c52g0s095vfi.out 652,976 11-20-2019 01:54 23458191 fh_ns325d1c52g0s100vfi.inp 4,255 11-18-2019 16:19 32379ec2 fh_ns325d1c52g0s100vfi.out 652,466 11-20-2019 02:00 8a0b67bc
\\v1.2\\fj\\ (0) 28,893,737 11-18-2019 15:33
\\v1.2\\fj\\ha245\\ (22) 7,211,066 11-18-2019 20:33 fj_ha245a1c52g1s0500hx.inp 3,894 11-18-2019 09:42 8ae5206f fj_ha245a1c52g1s0500hx.out 651,937 11-18-2019 16:02 23162882 fj_ha245a1c52g1s0600hx.inp 3,895 11-18-2019 09:43 3994e07b fj_ha245a1c52g1s0600hx.out 651,085 11-18-2019 16:08 32b915e6 fj_ha245a1c52g1s0700hx.inp 3,895 11-18-2019 09:43 27938b5f fj_ha245a1c52g1s0700hx.out 652,648 11-18-2019 16:02 14d17d96 fj_ha245a1c52g1s0800hx.inp 3,895 11-18-2019 09:43 c082119c fj_ha245a1c52g1s0800hx.out 650,907 11-18-2019 16:02 4044f389 fj_ha245a1c52g1s0900hx.inp 3,895 11-18-2019 09:43 332a2f78 fj_ha245a1c52g1s0900hx.out 651,346 11-18-2019 16:10 b8b7ee48 fj_ha245a1c52g1s1000hx.inp 3,899 11-18-2019 09:43 45546e35 fj_ha245a1c52g1s1000hx.out 651,453 11-18-2019 16:05 c9b5ee04 fj_ha245a1c52g1s1100hx.inp 3,899 11-18-2019 09:43 37c568d3 fj_ha245a1c52g1s1100hx.out 651,650 11-18-2019 16:02 ca958a51 fj_ha245a1c52g1s1200hx.inp 3,899 11-18-2019 09:43 aaa8f47a fj_ha245a1c52g1s1200hx.out 652,719 11-18-2019 16:05 155cdca8 fj_ha245a1c52g1s1300hx.inp 3,899 11-18-2019 09:43 010d4da9 fj_ha245a1c52g1s1300hx.out 650,853 11-18-2019 16:07 e82d73fe fj_ha245a1c52g1s1400hx.inp 3,899 11-18-2019 09:43 610aecf4 fj_ha245a1c52g1s1400hx.out 651,813 11-18-2019 16:07 6b534e6e fj_ha245a1c52g1s1500hx.inp 3,899 11-18-2019 09:43 bb2d63d8 fj_ha245a1c52g1s1500hx.out 651,787 11-18-2019 16:11 8c022ca4
\\v1.2\\fj\\ha325\\ (22) 7,233,379 11-18-2019 20:33 fj_ha325a1c52g1s0500hx.inp 4,082 11-18-2019 01:34 2c55bf03 fj_ha325a1c52g1s0500hx.out 653,374 11-18-2019 07:45 6548e70d fj_ha325a1c52g1s0600hx.inp 4,082 11-18-2019 01:34 d8513c94 fj_ha325a1c52g1s0600hx.out 652,736 11-18-2019 07:56 ad84e758 fj_ha325a1c52g1s0700hx.inp 4,082 11-18-2019 01:34 cc0b7318 fj_ha325a1c52g1s0700hx.out 653,486 11-18-2019 08:12 c5d63d87 fj_ha325a1c52g1s0800hx.inp 4,082 11-18-2019 01:34 c1a45c06 fj_ha325a1c52g1s0800hx.out 652,581 11-18-2019 08:04 207244f0 fj_ha325a1c52g1s0900hx.inp 4,082 11-18-2019 01:34 f3dbd608 fj_ha325a1c52g1s0900hx.out 653,508 11-18-2019 08:07 4f343214 fj_ha325a1c52g1s1000hx.inp 4,086 11-18-2019 01:34 b2959fe6 fj_ha325a1c52g1s1000hx.out 653,670 11-18-2019 07:54 3e2fdc34 fj_ha325a1c52g1s1100hx.inp 4,086 11-18-2019 01:35 7af07d96 fj_ha325a1c52g1s1100hx.out 654,277 11-18-2019 07:32 57bed71a fj_ha325a1c52g1s1200hx.inp 4,086 11-18-2019 01:35 0fcd62af fj_ha325a1c52g1s1200hx.out 653,631 11-18-2019 08:11 cc076593 fj_ha325a1c52g1s1300hx.inp 4,086 11-18-2019 01:35 eb2557d6 fj_ha325a1c52g1s1300hx.out 653,912 11-18-2019 07:36 9ddecae0 fj_ha325a1c52g1s1400hx.inp 4,086 11-18-2019 01:35 95d1a1f2 fj_ha325a1c52g1s1400hx.out 652,730 11-18-2019 07:35 4ebba534 fj_ha325a1c52g1s1500hx.inp 4,086 11-18-2019 01:35 d5f0f31c fj_ha325a1c52g1s1500hx.out 654,548 11-18-2019 08:14 8fd2e6b0
\\v1.2\\fj\\na245\\ (22) 7,212,865 11-20-2019 09:22 fj_na245a1c52g1s0500hx.inp 3,894 11-18-2019 11:52 bb8ff5f9 fj_na245a1c52g1s0500hx.out 651,192 11-19-2019 07:53 85d85a4c fj_na245a1c52g1s0600hx.inp 3,895 11-18-2019 11:52 d15c7725 fj_na245a1c52g1s0600hx.out 651,334 11-19-2019 07:52 74f811b4 fj_na245a1c52g1s0700hx.inp 3,895 11-18-2019 11:52 cf5b1c01 fj_na245a1c52g1s0700hx.out 651,640 11-19-2019 07:50 739128c4 fj_na245a1c52g1s0800hx.inp 3,895 11-18-2019 11:52 284a86c2 fj_na245a1c52g1s0800hx.out 651,432 11-19-2019 07:50 3c814b64 fj_na245a1c52g1s0900hx.inp 3,895 11-18-2019 11:52 dbe2b826
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
141 of 190 fj_na245a1c52g1s0900hx.out 651,877 11-19-2019 07:51 50b3d4cf fj_na245a1c52g1s1000hx.inp 3,899 11-18-2019 11:52 32afbf23 fj_na245a1c52g1s1000hx.out 652,792 11-19-2019 08:02 209955a2 fj_na245a1c52g1s1100hx.inp 3,899 11-18-2019 11:52 403eb9c5 fj_na245a1c52g1s1100hx.out 651,511 11-19-2019 07:56 438b6813 fj_na245a1c52g1s1200hx.inp 3,899 11-18-2019 11:52 dd53256c fj_na245a1c52g1s1200hx.out 652,398 11-19-2019 07:53 ff4732d1 fj_na245a1c52g1s1300hx.inp 3,899 11-18-2019 11:53 76f69cbf fj_na245a1c52g1s1300hx.out 652,553 11-19-2019 08:04 b5fed8b9 fj_na245a1c52g1s1400hx.inp 3,899 11-18-2019 11:53 16f13de2 fj_na245a1c52g1s1400hx.out 652,329 11-19-2019 08:03 d42b6283 fj_na245a1c52g1s1500hx.inp 3,899 11-18-2019 11:53 ccd6b2ce fj_na245a1c52g1s1500hx.out 650,939 11-19-2019 08:13 d2a565bf
\\v1.2\\fj\\na325\\ (22) 7,236,427 11-20-2019 09:22 fj_na325a1c52g1s0500hx.inp 4,114 11-18-2019 10:48 6d036fa8 fj_na325a1c52g1s0500hx.out 654,201 11-19-2019 00:41 336b3a8c fj_na325a1c52g1s0600hx.inp 4,114 11-18-2019 10:48 af58721a fj_na325a1c52g1s0600hx.out 653,521 11-19-2019 00:05 7fcb11a3 fj_na325a1c52g1s0700hx.inp 4,114 11-18-2019 10:48 065172c0 fj_na325a1c52g1s0700hx.out 653,453 11-19-2019 00:13 fad632ff fj_na325a1c52g1s0800hx.inp 4,114 11-18-2019 10:48 629e7078 fj_na325a1c52g1s0800hx.out 652,969 11-19-2019 00:07 4dfb26c5 fj_na325a1c52g1s0900hx.inp 4,114 11-18-2019 10:48 3a4ad3de fj_na325a1c52g1s0900hx.out 652,960 11-19-2019 00:17 1d99ddec fj_na325a1c52g1s1000hx.inp 4,118 11-18-2019 10:48 34415849 fj_na325a1c52g1s1000hx.out 654,548 11-19-2019 00:14 2610338a fj_na325a1c52g1s1100hx.inp 4,118 11-18-2019 10:48 8544f7bd fj_na325a1c52g1s1100hx.out 652,842 11-19-2019 00:49 95b9746d fj_na325a1c52g1s1200hx.inp 4,118 11-18-2019 10:48 5d6bb532 fj_na325a1c52g1s1200hx.out 653,952 11-18-2019 23:58 d4b1ed40 fj_na325a1c52g1s1300hx.inp 4,118 11-18-2019 10:48 549d8afe fj_na325a1c52g1s1300hx.out 654,167 11-19-2019 00:12 d1068e7f fj_na325a1c52g1s1400hx.inp 4,118 11-18-2019 10:48 2812743d fj_na325a1c52g1s1400hx.out 653,893 11-19-2019 01:02 76f41d3f fj_na325a1c52g1s1500hx.inp 4,118 11-18-2019 10:48 b313b89c fj_na325a1c52g1s1500hx.out 654,643 11-19-2019 00:20 35af90e7
\\v1.2\\fl\\ (0) 23,644,982 11-18-2019 15:33
\\v1.2\\fl\\ha245\\ (18) 5,901,293 11-22-2019 12:48 fl_ha245a1c52g1s001vfio.inp 3,895 11-18-2019 09:43 d0383acc fl_ha245a1c52g1s001vfio.out 652,133 11-18-2019 15:20 a17494ac fl_ha245a1c52g1s005vfio.inp 3,895 11-18-2019 09:44 59e99293 fl_ha245a1c52g1s005vfio.out 650,940 11-18-2019 14:53 23bca8bc fl_ha245a1c52g1s010vfio.inp 3,895 11-18-2019 09:44 7a77ec05 fl_ha245a1c52g1s010vfio.out 652,512 11-18-2019 15:05 d35135dd fl_ha245a1c52g1s030vfio.inp 3,895 11-18-2019 09:44 541e5dbb fl_ha245a1c52g1s030vfio.out 651,453 11-18-2019 15:36 701de4c5 fl_ha245a1c52g1s050vfio.inp 3,895 11-18-2019 09:44 559336dc fl_ha245a1c52g1s050vfio.out 652,344 11-18-2019 15:48 a4dfac06 fl_ha245a1c52g1s070vfio.inp 3,895 11-18-2019 09:44 65f26724 fl_ha245a1c52g1s070vfio.out 651,937 11-18-2019 16:04 a960d497 fl_ha245a1c52g1s090vfio.inp 3,895 11-18-2019 09:44 54ed3b13 fl_ha245a1c52g1s090vfio.out 652,084 11-18-2019 16:05 8afab254 fl_ha245a1c52g1s095vfio.inp 3,895 11-18-2019 09:44 1a504c64 fl_ha245a1c52g1s095vfio.out 651,487 11-18-2019 16:06 ce190ee6 fl_ha245a1c52g1s100vfio.inp 3,895 11-18-2019 09:44 332a2f78 fl_ha245a1c52g1s100vfio.out 651,348 11-18-2019 16:13 4261b12d
\\v1.2\\fl\\ha325\\ (18) 5,920,866 11-22-2019 12:48 fl_ha325a1c52g1s001vfio.inp 4,082 11-18-2019 01:35 81e42e1b fl_ha325a1c52g1s001vfio.out 653,227 11-18-2019 07:26 8b05aaa8 fl_ha325a1c52g1s005vfio.inp 4,082 11-18-2019 01:35 46109b4f fl_ha325a1c52g1s005vfio.out 654,278 11-18-2019 06:53 26a779b4 fl_ha325a1c52g1s010vfio.inp 4,082 11-18-2019 01:35 831f1f3d fl_ha325a1c52g1s010vfio.out 654,857 11-18-2019 07:12 0929512c fl_ha325a1c52g1s030vfio.inp 4,082 11-18-2019 01:35 7db2a201 fl_ha325a1c52g1s030vfio.out 654,101 11-18-2019 07:17 7b0296c9 fl_ha325a1c52g1s050vfio.inp 4,082 11-18-2019 01:35 a54780cc fl_ha325a1c52g1s050vfio.out 653,773 11-18-2019 07:58 dc57c0c0 fl_ha325a1c52g1s070vfio.inp 4,082 11-18-2019 01:35 21f0c08e fl_ha325a1c52g1s070vfio.out 653,463 11-18-2019 08:15 f267525a fl_ha325a1c52g1s090vfio.inp 4,082 11-18-2019 01:36 14e3c70d fl_ha325a1c52g1s090vfio.out 653,538 11-18-2019 08:20 96717f3f fl_ha325a1c52g1s095vfio.inp 4,082 11-18-2019 01:36 070f8504 fl_ha325a1c52g1s095vfio.out 653,388 11-18-2019 08:19 1296c4cb
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
142 of 190 fl_ha325a1c52g1s100vfio.inp 4,082 11-18-2019 01:36 f3dbd608 fl_ha325a1c52g1s100vfio.out 653,503 11-18-2019 08:18 e486eb40
\\v1.2\\fl\\na245\\ (18) 5,901,846 11-22-2019 12:48 fl_na245a1c52g1s001vfio.inp 3,895 11-18-2019 11:53 38f0ad92 fl_na245a1c52g1s001vfio.out 651,804 11-19-2019 07:17 ae5d70bc fl_na245a1c52g1s005vfio.inp 3,895 11-18-2019 11:53 b12105cd fl_na245a1c52g1s005vfio.out 652,140 11-19-2019 06:54 51b49774 fl_na245a1c52g1s010vfio.inp 3,895 11-18-2019 11:53 92bf7b5b fl_na245a1c52g1s010vfio.out 652,238 11-19-2019 07:02 1fc72af0 fl_na245a1c52g1s030vfio.inp 3,895 11-18-2019 11:53 bcd6cae5 fl_na245a1c52g1s030vfio.out 651,726 11-19-2019 07:31 64ba4691 fl_na245a1c52g1s050vfio.inp 3,895 11-18-2019 11:53 bd5ba182 fl_na245a1c52g1s050vfio.out 651,967 11-19-2019 07:58 6e7db3ba fl_na245a1c52g1s070vfio.inp 3,895 11-18-2019 11:53 8d3af07a fl_na245a1c52g1s070vfio.out 651,462 11-19-2019 07:46 d26d57a5 fl_na245a1c52g1s090vfio.inp 3,895 11-18-2019 11:53 bc25ac4d fl_na245a1c52g1s090vfio.out 651,828 11-19-2019 08:02 8b3d9e86 fl_na245a1c52g1s095vfio.inp 3,895 11-18-2019 11:53 f298db3a fl_na245a1c52g1s095vfio.out 651,750 11-19-2019 08:01 809b1b8b fl_na245a1c52g1s100vfio.inp 3,895 11-18-2019 11:54 dbe2b826 fl_na245a1c52g1s100vfio.out 651,876 11-19-2019 08:11 bee84238
\\v1.2\\fl\\na325\\ (18) 5,920,977 11-22-2019 12:48 fl_na325a1c52g1s001vfio.inp 4,114 11-18-2019 10:49 40013fd8 fl_na325a1c52g1s001vfio.out 654,472 11-18-2019 23:37 02655158 fl_na325a1c52g1s005vfio.inp 4,114 11-18-2019 10:49 c1343b52 fl_na325a1c52g1s005vfio.out 654,484 11-18-2019 23:04 b4ed24b7 fl_na325a1c52g1s010vfio.inp 4,114 11-18-2019 10:49 d42e611b fl_na325a1c52g1s010vfio.out 653,983 11-18-2019 23:10 c99b9b64 fl_na325a1c52g1s030vfio.inp 4,114 11-18-2019 10:49 08e5a510 fl_na325a1c52g1s030vfio.out 653,296 11-18-2019 23:45 ae4dfafb fl_na325a1c52g1s050vfio.inp 4,114 11-18-2019 10:49 38690a98 fl_na325a1c52g1s050vfio.out 653,413 11-19-2019 00:01 dbdf5689 fl_na325a1c52g1s070vfio.inp 4,114 11-18-2019 10:49 0f3e1afc fl_na325a1c52g1s070vfio.out 653,413 11-19-2019 00:09 b8f78073 fl_na325a1c52g1s090vfio.inp 4,114 11-18-2019 10:49 855b679a fl_na325a1c52g1s090vfio.out 654,342 11-19-2019 00:18 576e1cd1 fl_na325a1c52g1s095vfio.inp 4,114 11-18-2019 10:49 4b673656 fl_na325a1c52g1s095vfio.out 653,586 11-19-2019 00:23 781be023 fl_na325a1c52g1s100vfio.inp 4,114 11-18-2019 10:49 3a4ad3de fl_na325a1c52g1s100vfio.out 652,962 11-19-2019 00:31 9b34e837
\\v1.2\\ga\\ (0) 57,783,293 11-18-2019 17:24
\\v1.2\\ga\\ha245\\ (22) 7,246,455 11-18-2019 20:33 ga_ha245e2c32g1s0500hx.inp 4,045 11-18-2019 02:27 2022c5f6 ga_ha245e2c32g1s0500hx.out 654,533 11-18-2019 16:20 e97eadc4 ga_ha245e2c32g1s0600hx.inp 4,046 11-18-2019 02:27 fc782160 ga_ha245e2c32g1s0600hx.out 654,498 11-18-2019 16:22 ff3013d4 ga_ha245e2c32g1s0700hx.inp 4,046 11-18-2019 02:27 f092cd19 ga_ha245e2c32g1s0700hx.out 654,359 11-18-2019 16:13 434fc6ee ga_ha245e2c32g1s0800hx.inp 4,046 11-18-2019 02:27 2b950ec5 ga_ha245e2c32g1s0800hx.out 654,194 11-18-2019 16:19 559664e6 ga_ha245e2c32g1s0900hx.inp 4,046 11-18-2019 02:27 9cc28cdc ga_ha245e2c32g1s0900hx.out 654,863 11-18-2019 16:13 4d56b1ef ga_ha245e2c32g1s1000hx.inp 4,050 11-18-2019 02:27 f6c47edc ga_ha245e2c32g1s1000hx.out 654,475 11-18-2019 16:14 077fca66 ga_ha245e2c32g1s1100hx.inp 4,050 11-18-2019 02:28 c237e141 ga_ha245e2c32g1s1100hx.out 655,036 11-18-2019 16:16 0ed44453 ga_ha245e2c32g1s1200hx.inp 4,050 11-18-2019 02:28 4d0a7d3b ga_ha245e2c32g1s1200hx.out 654,733 11-18-2019 16:16 01e6f2a4 ga_ha245e2c32g1s1300hx.inp 4,050 11-18-2019 02:28 7164ed38 ga_ha245e2c32g1s1300hx.out 654,579 11-18-2019 16:16 956079de ga_ha245e2c32g1s1400hx.inp 4,050 11-18-2019 02:28 d7360c35 ga_ha245e2c32g1s1400hx.out 655,248 11-18-2019 16:18 699f0c32 ga_ha245e2c32g1s1500hx.inp 4,050 11-18-2019 02:28 8cfb35ae ga_ha245e2c32g1s1500hx.out 655,408 11-18-2019 16:28 07059fba
\\v1.2\\ga\\ha325\\ (22) 7,233,745 11-18-2019 20:33 ga_ha325e2c32g1s0500hx.inp 3,991 11-18-2019 01:12 07b5a4a1 ga_ha325e2c32g1s0500hx.out 653,814 11-18-2019 06:26 123f532d ga_ha325e2c32g1s0600hx.inp 3,991 11-18-2019 01:12 1dd0b871 ga_ha325e2c32g1s0600hx.out 653,546 11-18-2019 06:30 19af575d ga_ha325e2c32g1s0700hx.inp 3,991 11-18-2019 01:12 e7ed8425 ga_ha325e2c32g1s0700hx.out 653,937 11-18-2019 06:23 4348c868
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
143 of 190 ga_ha325e2c32g1s0800hx.inp 3,991 11-18-2019 01:12 4a782248 ga_ha325e2c32g1s0800hx.out 653,783 11-18-2019 06:22 afc8ae62 ga_ha325e2c32g1s0900hx.inp 3,991 11-18-2019 01:12 a8d7c58e ga_ha325e2c32g1s0900hx.out 653,578 11-18-2019 06:22 40ad348b ga_ha325e2c32g1s1000hx.inp 3,995 11-18-2019 01:12 b816b465 ga_ha325e2c32g1s1000hx.out 654,052 11-18-2019 06:26 53597846 ga_ha325e2c32g1s1100hx.inp 3,995 11-18-2019 01:12 ebda5101 ga_ha325e2c32g1s1100hx.out 653,770 11-18-2019 06:28 e4811a62 ga_ha325e2c32g1s1200hx.inp 3,995 11-18-2019 01:12 fd5d9cef ga_ha325e2c32g1s1200hx.out 652,839 11-18-2019 06:26 c2ea435e ga_ha325e2c32g1s1300hx.inp 3,995 11-18-2019 01:12 a339eaf2 ga_ha325e2c32g1s1300hx.out 653,921 11-18-2019 06:28 df79cd79 ga_ha325e2c32g1s1400hx.inp 3,995 11-18-2019 01:12 53fa46eb ga_ha325e2c32g1s1400hx.out 652,814 11-18-2019 06:30 5e79a78d ga_ha325e2c32g1s1500hx.inp 3,994 11-18-2019 01:12 02f5a5f2 ga_ha325e2c32g1s1500hx.out 653,767 11-18-2019 06:32 91a18d2e
\\v1.2\\ga\\hs245\\ (22) 7,248,383 11-20-2019 09:22 ga_hs245e2c32g1s0500hx.inp 4,073 11-18-2019 14:52 405ff397 ga_hs245e2c32g1s0500hx.out 654,081 11-19-2019 20:36 30f27c9d ga_hs245e2c32g1s0600hx.inp 4,074 11-18-2019 14:52 150c0899 ga_hs245e2c32g1s0600hx.out 655,607 11-19-2019 20:36 0f10cfb3 ga_hs245e2c32g1s0700hx.inp 4,074 11-18-2019 14:52 33858a9f ga_hs245e2c32g1s0700hx.out 654,188 11-19-2019 20:31 04eab00c ga_hs245e2c32g1s0800hx.inp 4,074 11-18-2019 14:53 c16e17bd ga_hs245e2c32g1s0800hx.out 654,889 11-19-2019 20:33 06306ed8 ga_hs245e2c32g1s0900hx.inp 4,074 11-18-2019 14:53 8591e11f ga_hs245e2c32g1s0900hx.out 654,515 11-19-2019 20:38 c481cee2 ga_hs245e2c32g1s1000hx.inp 4,078 11-18-2019 14:53 030262c5 ga_hs245e2c32g1s1000hx.out 656,107 11-19-2019 20:33 8c4d579e ga_hs245e2c32g1s1100hx.inp 4,078 11-18-2019 14:53 406d55ad ga_hs245e2c32g1s1100hx.out 654,804 11-19-2019 20:36 7fd6bd55 ga_hs245e2c32g1s1200hx.inp 4,078 11-18-2019 14:53 ed20c29b ga_hs245e2c32g1s1200hx.out 655,079 11-19-2019 20:37 b884ef12 ga_hs245e2c32g1s1300hx.inp 4,078 11-18-2019 14:53 9acb5f75 ga_hs245e2c32g1s1300hx.out 655,316 11-19-2019 20:40 f36a16ab ga_hs245e2c32g1s1400hx.inp 4,078 11-18-2019 14:53 ef2afdbd ga_hs245e2c32g1s1400hx.out 655,007 11-19-2019 20:39 6b424bdc ga_hs245e2c32g1s1500hx.inp 4,078 11-18-2019 14:53 f72c8312 ga_hs245e2c32g1s1500hx.out 653,953 11-19-2019 20:49 1da9a517
\\v1.2\\ga\\hs325\\ (22) 7,234,451 11-20-2019 09:22 ga_hs325e2c32g1s0500hx.inp 4,024 11-18-2019 13:04 d5e7ca8d ga_hs325e2c32g1s0500hx.out 653,196 11-19-2019 15:22 a81a6f71 ga_hs325e2c32g1s0600hx.inp 4,024 11-18-2019 13:05 1d2eaacf ga_hs325e2c32g1s0600hx.out 653,298 11-19-2019 15:13 a7f0cdd0 ga_hs325e2c32g1s0700hx.inp 4,024 11-18-2019 13:05 5f0617c1 ga_hs325e2c32g1s0700hx.out 652,792 11-19-2019 15:14 aa9ae111 ga_hs325e2c32g1s0800hx.inp 4,024 11-18-2019 13:05 08ebf84b ga_hs325e2c32g1s0800hx.out 653,930 11-19-2019 15:13 a475ef7b ga_hs325e2c32g1s0900hx.inp 4,024 11-18-2019 13:05 d4f29d99 ga_hs325e2c32g1s0900hx.out 654,947 11-19-2019 15:00 e6d8d806 ga_hs325e2c32g1s1000hx.inp 4,028 11-18-2019 13:05 2a76c1b7 ga_hs325e2c32g1s1000hx.out 654,102 11-19-2019 15:09 dc038b14 ga_hs325e2c32g1s1100hx.inp 4,028 11-18-2019 13:05 cd2c7e41 ga_hs325e2c32g1s1100hx.out 652,793 11-19-2019 15:08 6f57ccb1 ga_hs325e2c32g1s1200hx.inp 4,028 11-18-2019 13:05 a80d6804 ga_hs325e2c32g1s1200hx.out 653,575 11-19-2019 15:25 9b1146c7 ga_hs325e2c32g1s1300hx.inp 4,028 11-18-2019 13:05 707e57cc ga_hs325e2c32g1s1300hx.out 653,528 11-19-2019 15:13 64097e1a ga_hs325e2c32g1s1400hx.inp 4,028 11-18-2019 13:05 46da6af6 ga_hs325e2c32g1s1400hx.out 654,297 11-19-2019 15:20 e5fc73fb ga_hs325e2c32g1s1500hx.inp 4,027 11-18-2019 13:05 25ebb476 ga_hs325e2c32g1s1500hx.out 653,706 11-19-2019 15:18 7b859ed9
\\v1.2\\ga\\na245\\ (22) 7,101,042 11-20-2019 09:22 ga_na245e2c32g1s0500hx.inp 4,072 11-18-2019 11:42 9f2f1ad1 ga_na245e2c32g1s0500hx.out 507,917 11-19-2019 08:20 e12bfd61 ga_na245e2c32g1s0600hx.inp 4,073 11-18-2019 11:42 d695187d ga_na245e2c32g1s0600hx.out 654,665 11-19-2019 08:19 5e22916e ga_na245e2c32g1s0700hx.inp 4,073 11-18-2019 11:42 e2eec11f ga_na245e2c32g1s0700hx.out 654,698 11-19-2019 08:15 f216ec60 ga_na245e2c32g1s0800hx.inp 4,073 11-18-2019 11:42 f386a49e ga_na245e2c32g1s0800hx.out 654,047 11-19-2019 08:13 60c1d654 ga_na245e2c32g1s0900hx.inp 4,073 11-18-2019 11:42 223f4370 ga_na245e2c32g1s0900hx.out 654,660 11-19-2019 08:17 b5551ac4 ga_na245e2c32g1s1000hx.inp 4,077 11-18-2019 11:42 8ee98aa0 ga_na245e2c32g1s1000hx.out 654,488 11-19-2019 08:10 eef48894
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
144 of 190 ga_na245e2c32g1s1100hx.inp 4,077 11-18-2019 11:43 5ea8b3a1 ga_na245e2c32g1s1100hx.out 657,069 11-19-2019 08:16 16ba34de ga_na245e2c32g1s1200hx.inp 4,077 11-18-2019 11:43 3890b162 ga_na245e2c32g1s1200hx.out 654,471 11-19-2019 08:19 efc9c2a2 ga_na245e2c32g1s1300hx.inp 4,077 11-18-2019 11:43 a6573fa3 ga_na245e2c32g1s1300hx.out 655,001 11-19-2019 08:23 2d392eb5 ga_na245e2c32g1s1400hx.inp 4,077 11-18-2019 11:43 3765a85c ga_na245e2c32g1s1400hx.out 654,829 11-19-2019 08:29 7b9609c4 ga_na245e2c32g1s1500hx.inp 4,077 11-18-2019 11:43 bd7cfe72 ga_na245e2c32g1s1500hx.out 654,371 11-19-2019 08:24 89fbd0d9
\\v1.2\\ga\\na325\\ (22) 7,236,058 11-20-2019 09:22 ga_na325e2c32g1s0500hx.inp 4,023 11-18-2019 10:38 cca1c097 ga_na325e2c32g1s0500hx.out 653,746 11-19-2019 00:29 5b65007b ga_na325e2c32g1s0600hx.inp 4,023 11-18-2019 10:39 2fce8379 ga_na325e2c32g1s0600hx.out 653,504 11-19-2019 00:33 d4212e20 ga_na325e2c32g1s0700hx.inp 4,023 11-18-2019 10:39 badf51bc ga_na325e2c32g1s0700hx.out 653,102 11-19-2019 00:32 e18a20e8 ga_na325e2c32g1s0800hx.inp 4,023 11-18-2019 10:39 c63fefce ga_na325e2c32g1s0800hx.out 653,340 11-19-2019 00:27 720e913a ga_na325e2c32g1s0900hx.inp 4,023 11-18-2019 10:39 958cb6e1 ga_na325e2c32g1s0900hx.out 654,005 11-19-2019 00:38 05fc40c5 ga_na325e2c32g1s1000hx.inp 4,027 11-18-2019 10:39 ed67fe03 ga_na325e2c32g1s1000hx.out 654,280 11-19-2019 00:39 a49d5395 ga_na325e2c32g1s1100hx.inp 4,027 11-18-2019 10:39 3de605df ga_na325e2c32g1s1100hx.out 654,054 11-19-2019 00:20 9c8d4d59 ga_na325e2c32g1s1200hx.inp 4,027 11-18-2019 10:39 0a3f2086 ga_na325e2c32g1s1200hx.out 653,781 11-19-2019 00:36 dd1575ff ga_na325e2c32g1s1300hx.inp 4,027 11-18-2019 10:39 5fa0be81 ga_na325e2c32g1s1300hx.out 654,934 11-19-2019 00:37 ebcd773e ga_na325e2c32g1s1400hx.inp 4,027 11-18-2019 10:39 fa487252 ga_na325e2c32g1s1400hx.out 653,216 11-19-2019 00:26 41f961ce ga_na325e2c32g1s1500hx.inp 4,026 11-18-2019 10:39 2f995af5 ga_na325e2c32g1s1500hx.out 653,820 11-19-2019 00:43 0b2f5c50
\\v1.2\\ga\\ns245\\ (22) 7,248,002 11-20-2019 09:22 ga_ns245e2c32g1s0500hx.inp 4,073 11-18-2019 17:24 2ba8cdc5 ga_ns245e2c32g1s0500hx.out 654,937 11-20-2019 06:44 75e12d9c ga_ns245e2c32g1s0600hx.inp 4,074 11-18-2019 17:24 a2ebc2d0 ga_ns245e2c32g1s0600hx.out 654,582 11-20-2019 06:13 714f6b7a ga_ns245e2c32g1s0700hx.inp 4,074 11-18-2019 17:24 846240d6 ga_ns245e2c32g1s0700hx.out 653,698 11-20-2019 06:55 2edda0a9 ga_ns245e2c32g1s0800hx.inp 4,074 11-18-2019 17:24 7689ddf4 ga_ns245e2c32g1s0800hx.out 655,167 11-20-2019 06:08 ec662e49 ga_ns245e2c32g1s0900hx.inp 4,074 11-18-2019 17:25 32762b56 ga_ns245e2c32g1s0900hx.out 655,079 11-20-2019 06:50 116ff014 ga_ns245e2c32g1s1000hx.inp 4,078 11-18-2019 17:25 0986dee9 ga_ns245e2c32g1s1000hx.out 654,967 11-20-2019 06:55 bdcf0a61 ga_ns245e2c32g1s1100hx.inp 4,078 11-18-2019 17:25 4ae9e981 ga_ns245e2c32g1s1100hx.out 655,456 11-20-2019 06:56 9dd4d976 ga_ns245e2c32g1s1200hx.inp 4,078 11-18-2019 17:25 e7a47eb7 ga_ns245e2c32g1s1200hx.out 654,685 11-20-2019 06:28 dd648fdc ga_ns245e2c32g1s1300hx.inp 4,078 11-18-2019 17:25 904fe359 ga_ns245e2c32g1s1300hx.out 654,992 11-20-2019 06:28 78b5c519 ga_ns245e2c32g1s1400hx.inp 4,078 11-18-2019 17:25 e5ae4191 ga_ns245e2c32g1s1400hx.out 655,230 11-20-2019 06:20 61bd93e3 ga_ns245e2c32g1s1500hx.inp 4,078 11-18-2019 17:25 fda83f3e ga_ns245e2c32g1s1500hx.out 654,372 11-20-2019 06:57 2ed71b6f
\\v1.2\\ga\\ns325\\ (22) 7,235,157 11-20-2019 09:22 ga_ns325e2c32g1s0500hx.inp 4,024 11-18-2019 16:19 d55f64c1 ga_ns325e2c32g1s0500hx.out 653,916 11-20-2019 01:57 22670801 ga_ns325e2c32g1s0600hx.inp 4,024 11-18-2019 16:19 1d960483 ga_ns325e2c32g1s0600hx.out 653,796 11-20-2019 01:59 1ab590ad ga_ns325e2c32g1s0700hx.inp 4,024 11-18-2019 16:19 5fbeb98d ga_ns325e2c32g1s0700hx.out 653,442 11-20-2019 02:01 dd2d9add ga_ns325e2c32g1s0800hx.inp 4,024 11-18-2019 16:19 08535607 ga_ns325e2c32g1s0800hx.out 652,951 11-20-2019 02:06 1b03d790 ga_ns325e2c32g1s0900hx.inp 4,024 11-18-2019 16:20 d44a33d5 ga_ns325e2c32g1s0900hx.out 653,773 11-20-2019 02:00 641f4e9a ga_ns325e2c32g1s1000hx.inp 4,028 11-18-2019 16:20 9a1d81ee ga_ns325e2c32g1s1000hx.out 654,698 11-20-2019 01:55 616f8f21 ga_ns325e2c32g1s1100hx.inp 4,028 11-18-2019 16:20 7d473e18 ga_ns325e2c32g1s1100hx.out 653,469 11-20-2019 01:57 38f976f2 ga_ns325e2c32g1s1200hx.inp 4,028 11-18-2019 16:20 1866285d ga_ns325e2c32g1s1200hx.out 653,564 11-20-2019 02:07 4bf2804e ga_ns325e2c32g1s1300hx.inp 4,028 11-18-2019 16:20 c0151795 ga_ns325e2c32g1s1300hx.out 653,536 11-20-2019 02:01 7c16f1e9
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
145 of 190 ga_ns325e2c32g1s1400hx.inp 4,028 11-18-2019 16:20 f6b12aaf ga_ns325e2c32g1s1400hx.out 653,512 11-20-2019 02:04 f5405053 ga_ns325e2c32g1s1500hx.inp 4,027 11-18-2019 16:20 af528320 ga_ns325e2c32g1s1500hx.out 654,213 11-20-2019 02:04 0e163704
\\v1.2\\gb\\ (0) 52,656,991 11-18-2019 17:25
\\v1.2\\gb\\ha245\\ (22) 7,244,359 11-18-2019 20:33 gb_ha245e2c32g1s0500hx.inp 4,050 11-18-2019 02:28 5f8f45d1 gb_ha245e2c32g1s0500hx.out 655,125 11-18-2019 16:21 16098af5 gb_ha245e2c32g1s0600hx.inp 4,051 11-18-2019 02:28 3d0fe273 gb_ha245e2c32g1s0600hx.out 654,596 11-18-2019 16:18 28066fc6 gb_ha245e2c32g1s0700hx.inp 4,051 11-18-2019 02:28 83292879 gb_ha245e2c32g1s0700hx.out 653,831 11-18-2019 16:18 08889942 gb_ha245e2c32g1s0800hx.inp 4,051 11-18-2019 02:28 7b605547 gb_ha245e2c32g1s0800hx.out 654,751 11-18-2019 16:18 aacd79a3 gb_ha245e2c32g1s0900hx.inp 4,049 11-18-2019 02:28 0cb4a589 gb_ha245e2c32g1s0900hx.out 654,736 11-18-2019 16:23 da864f36 gb_ha245e2c32g1s1000hx.inp 4,053 11-18-2019 02:28 67b99542 gb_ha245e2c32g1s1000hx.out 654,324 11-18-2019 16:22 a1352703 gb_ha245e2c32g1s1100hx.inp 4,053 11-18-2019 02:29 42ec2cc9 gb_ha245e2c32g1s1100hx.out 653,643 11-18-2019 16:24 773b5564 gb_ha245e2c32g1s1200hx.inp 4,053 11-18-2019 02:29 57db8cca gb_ha245e2c32g1s1200hx.out 654,978 11-18-2019 16:20 77f3b7fd gb_ha245e2c32g1s1300hx.inp 4,053 11-18-2019 02:29 4a6b7e6f gb_ha245e2c32g1s1300hx.out 654,056 11-18-2019 16:28 66f58385 gb_ha245e2c32g1s1400hx.inp 4,053 11-18-2019 02:29 35b7ce5c gb_ha245e2c32g1s1400hx.out 655,186 11-18-2019 16:38 265ae8d9 gb_ha245e2c32g1s1500hx.inp 4,053 11-18-2019 02:29 c75e70d6 gb_ha245e2c32g1s1500hx.out 654,563 11-18-2019 16:30 30659509
\\v1.2\\gb\\ha325\\ (22) 7,233,322 11-18-2019 20:33 gb_ha325e2c32g1s0500hx.inp 3,996 11-18-2019 01:13 3d3412e1 gb_ha325e2c32g1s0500hx.out 653,567 11-18-2019 06:33 429de005 gb_ha325e2c32g1s0600hx.inp 3,994 11-18-2019 01:13 3f10a00a gb_ha325e2c32g1s0600hx.out 653,471 11-18-2019 06:24 b2073a19 gb_ha325e2c32g1s0700hx.inp 3,994 11-18-2019 01:13 a8a8dcfe gb_ha325e2c32g1s0700hx.out 654,061 11-18-2019 06:26 65d6cb2b gb_ha325e2c32g1s0800hx.inp 3,994 11-18-2019 01:13 55b9740b gb_ha325e2c32g1s0800hx.out 653,670 11-18-2019 06:25 0801fa54 gb_ha325e2c32g1s0900hx.inp 3,994 11-18-2019 01:13 b4c1f22c gb_ha325e2c32g1s0900hx.out 653,065 11-18-2019 06:29 30a7c37e gb_ha325e2c32g1s1000hx.inp 3,998 11-18-2019 01:13 4ed82ef9 gb_ha325e2c32g1s1000hx.out 653,890 11-18-2019 06:27 6971b8c4 gb_ha325e2c32g1s1100hx.inp 3,998 11-18-2019 01:13 e5a166ab gb_ha325e2c32g1s1100hx.out 653,708 11-18-2019 06:24 f2deed18 gb_ha325e2c32g1s1200hx.inp 3,998 11-18-2019 01:13 c1627fce gb_ha325e2c32g1s1200hx.out 652,853 11-18-2019 06:26 ae0cc463 gb_ha325e2c32g1s1300hx.inp 3,998 11-18-2019 01:13 536391e4 gb_ha325e2c32g1s1300hx.out 653,479 11-18-2019 06:28 022790bd gb_ha325e2c32g1s1400hx.inp 3,998 11-18-2019 01:13 d44ee898 gb_ha325e2c32g1s1400hx.out 653,910 11-18-2019 06:32 9ad0967d gb_ha325e2c32g1s1500hx.inp 3,998 11-18-2019 01:13 47fb358d gb_ha325e2c32g1s1500hx.out 653,688 11-18-2019 06:34 899f20b5
\\v1.2\\gb\\hs245\\ (22) 5,928,658 11-20-2019 09:22 gb_hs245e2c32g1s0500hx.inp 4,078 11-18-2019 14:53 560f1c4a gb_hs245e2c32g1s0500hx.out 508,395 11-19-2019 20:44 ed5ece01 gb_hs245e2c32g1s0600hx.inp 4,079 11-18-2019 14:53 c41d4511 gb_hs245e2c32g1s0600hx.out 508,333 11-19-2019 20:34 6756d9ca gb_hs245e2c32g1s0700hx.inp 4,079 11-18-2019 14:53 10f67680 gb_hs245e2c32g1s0700hx.out 508,169 11-19-2019 20:55 99c1f736 gb_hs245e2c32g1s0800hx.inp 4,079 11-18-2019 14:54 facd1df8 gb_hs245e2c32g1s0800hx.out 508,130 11-19-2019 20:37 69e22817 gb_hs245e2c32g1s0900hx.inp 4,077 11-18-2019 14:54 dadccb99 gb_hs245e2c32g1s0900hx.out 508,878 11-19-2019 20:50 b8dcb26d gb_hs245e2c32g1s1000hx.inp 4,081 11-18-2019 14:54 1dcba371 gb_hs245e2c32g1s1000hx.out 508,421 11-19-2019 20:41 085eadf4 gb_hs245e2c32g1s1100hx.inp 4,081 11-18-2019 14:54 46f58550 gb_hs245e2c32g1s1100hx.out 507,988 11-19-2019 20:37 2ed41ac0 gb_hs245e2c32g1s1200hx.inp 4,081 11-18-2019 14:54 d5e8e511 gb_hs245e2c32g1s1200hx.out 509,079 11-19-2019 20:52 af7a577e gb_hs245e2c32g1s1300hx.inp 4,081 11-18-2019 14:54 9393e145 gb_hs245e2c32g1s1300hx.out 507,348 11-19-2019 20:49 2640f77e gb_hs245e2c32g1s1400hx.inp 4,081 11-18-2019 14:54 e2a1752e gb_hs245e2c32g1s1400hx.out 654,443 11-19-2019 20:53 5d086c1c gb_hs245e2c32g1s1500hx.inp 4,081 11-18-2019 14:54 0fa0a089
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
146 of 190 gb_hs245e2c32g1s1500hx.out 654,596 11-19-2019 20:45 04b8bd30
\\v1.2\\gb\\hs325\\ (22) 6,649,897 11-20-2019 09:22 gb_hs325e2c32g1s0500hx.inp 4,029 11-18-2019 13:05 76760741 gb_hs325e2c32g1s0500hx.out 506,786 11-19-2019 15:16 0f7430f4 gb_hs325e2c32g1s0600hx.inp 4,027 11-18-2019 13:05 e5f80394 gb_hs325e2c32g1s0600hx.out 507,724 11-19-2019 15:13 e39cb629 gb_hs325e2c32g1s0700hx.inp 4,027 11-18-2019 13:06 f2180713 gb_hs325e2c32g1s0700hx.out 507,670 11-19-2019 15:25 76408e50 gb_hs325e2c32g1s0800hx.inp 4,027 11-18-2019 13:06 a7d0f930 gb_hs325e2c32g1s0800hx.out 507,724 11-19-2019 15:11 daae46cc gb_hs325e2c32g1s0900hx.inp 4,027 11-18-2019 13:06 e5a73cb2 gb_hs325e2c32g1s0900hx.out 653,268 11-19-2019 15:25 dd1112ef gb_hs325e2c32g1s1000hx.inp 4,031 11-18-2019 13:06 53d73bda gb_hs325e2c32g1s1000hx.out 653,902 11-19-2019 15:14 1874d847 gb_hs325e2c32g1s1100hx.inp 4,031 11-18-2019 13:06 52252dcb gb_hs325e2c32g1s1100hx.out 653,399 11-19-2019 15:11 4aec8699 gb_hs325e2c32g1s1200hx.inp 4,031 11-18-2019 13:06 8ed2eabf gb_hs325e2c32g1s1200hx.out 654,041 11-19-2019 15:13 ab2cee12 gb_hs325e2c32g1s1300hx.inp 4,031 11-18-2019 13:06 55a118ed gb_hs325e2c32g1s1300hx.out 654,147 11-19-2019 15:26 7a7e398a gb_hs325e2c32g1s1400hx.inp 4,031 11-18-2019 13:06 16e90d0c gb_hs325e2c32g1s1400hx.out 653,687 11-19-2019 15:27 ec8b206c gb_hs325e2c32g1s1500hx.inp 4,031 11-18-2019 13:06 d2317983 gb_hs325e2c32g1s1500hx.out 653,226 11-19-2019 15:26 ef5950b8
\\v1.2\\gb\\na245\\ (22) 5,637,101 11-20-2019 09:22 gb_na245e2c32g1s0500hx.inp 4,077 11-18-2019 11:43 d4a8f96e gb_na245e2c32g1s0500hx.out 507,958 11-19-2019 08:24 c204de85 gb_na245e2c32g1s0600hx.inp 4,078 11-18-2019 11:43 88c7d0da gb_na245e2c32g1s0600hx.out 508,138 11-19-2019 08:20 c69b806a gb_na245e2c32g1s0700hx.inp 4,078 11-18-2019 11:43 0d6adaec gb_na245e2c32g1s0700hx.out 508,931 11-19-2019 08:31 fd1ca697 gb_na245e2c32g1s0800hx.inp 4,078 11-18-2019 11:43 2f3e59a8 gb_na245e2c32g1s0800hx.out 508,295 11-19-2019 08:25 2b83c919 gb_na245e2c32g1s0900hx.inp 4,076 11-18-2019 11:43 eb0cf231 gb_na245e2c32g1s0900hx.out 508,101 11-19-2019 08:26 938220fb gb_na245e2c32g1s1000hx.inp 4,080 11-18-2019 11:43 8274ce95 gb_na245e2c32g1s1000hx.out 508,863 11-19-2019 08:26 d869fff8 gb_na245e2c32g1s1100hx.inp 4,080 11-18-2019 11:44 8e1affa1 gb_na245e2c32g1s1100hx.out 508,120 11-19-2019 08:35 58600a82 gb_na245e2c32g1s1200hx.inp 4,080 11-18-2019 11:44 ce0ac9cf gb_na245e2c32g1s1200hx.out 508,413 11-19-2019 08:26 2a09e8e7 gb_na245e2c32g1s1300hx.inp 4,080 11-18-2019 11:44 3ada5d75 gb_na245e2c32g1s1300hx.out 509,036 11-19-2019 08:37 5a41b7df gb_na245e2c32g1s1400hx.inp 4,080 11-18-2019 11:44 c791f5e7 gb_na245e2c32g1s1400hx.out 508,286 11-19-2019 08:31 6da35570 gb_na245e2c32g1s1500hx.inp 4,080 11-18-2019 11:44 953616e2 gb_na245e2c32g1s1500hx.out 508,093 11-19-2019 08:47 6b2e9a14
\\v1.2\\gb\\na325\\ (22) 6,211,392 11-20-2019 09:22 gb_na325e2c32g1s0500hx.inp 4,028 11-18-2019 10:39 28da6dd9 gb_na325e2c32g1s0500hx.out 507,114 11-19-2019 00:43 1560fc26 gb_na325e2c32g1s0600hx.inp 4,026 11-18-2019 10:39 c6113e06 gb_na325e2c32g1s0600hx.out 507,541 11-19-2019 00:43 7f1dd8bc gb_na325e2c32g1s0700hx.inp 4,026 11-18-2019 10:40 5f5d22db gb_na325e2c32g1s0700hx.out 506,680 11-19-2019 00:55 5384523d gb_na325e2c32g1s0800hx.inp 4,026 11-18-2019 10:40 17427358 gb_na325e2c32g1s0800hx.out 507,263 11-19-2019 00:36 e019ff2e gb_na325e2c32g1s0900hx.inp 4,026 11-18-2019 10:40 3e4ec198 gb_na325e2c32g1s0900hx.out 507,558 11-19-2019 00:39 6d8fb75e gb_na325e2c32g1s1000hx.inp 4,030 11-18-2019 10:40 db3155e6 gb_na325e2c32g1s1000hx.out 507,304 11-19-2019 00:34 23a37502 gb_na325e2c32g1s1100hx.inp 4,030 11-18-2019 10:40 6729b06d gb_na325e2c32g1s1100hx.out 507,251 11-19-2019 00:42 10a51d4a gb_na325e2c32g1s1200hx.inp 4,030 11-18-2019 10:40 998f44ab gb_na325e2c32g1s1200hx.out 653,873 11-19-2019 00:33 27fa7102 gb_na325e2c32g1s1300hx.inp 4,030 11-18-2019 10:40 a6f7de5c gb_na325e2c32g1s1300hx.out 654,142 11-19-2019 00:33 e168c90e gb_na325e2c32g1s1400hx.inp 4,030 11-18-2019 10:40 74a32604 gb_na325e2c32g1s1400hx.out 654,608 11-19-2019 00:45 d3afc9c5 gb_na325e2c32g1s1500hx.inp 4,030 11-18-2019 10:40 f937b895 gb_na325e2c32g1s1500hx.out 653,746 11-19-2019 00:38 283b9e2d
\\v1.2\\gb\\ns245\\ (22) 6,665,589 11-20-2019 09:22 gb_ns245e2c32g1s0500hx.inp 4,078 11-18-2019 17:25 f5d1d138 gb_ns245e2c32g1s0500hx.out 508,698 11-20-2019 06:33 9299481b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
147 of 190 gb_ns245e2c32g1s0600hx.inp 4,079 11-18-2019 17:25 485c8663 gb_ns245e2c32g1s0600hx.out 509,302 11-20-2019 06:30 d6642c60 gb_ns245e2c32g1s0700hx.inp 4,079 11-18-2019 17:25 9cb7b5f2 gb_ns245e2c32g1s0700hx.out 508,894 11-20-2019 07:00 73503ac6 gb_ns245e2c32g1s0800hx.inp 4,079 11-18-2019 17:25 768cde8a gb_ns245e2c32g1s0800hx.out 508,228 11-20-2019 06:42 66b86bd6 gb_ns245e2c32g1s0900hx.inp 4,077 11-18-2019 17:26 897081d7 gb_ns245e2c32g1s0900hx.out 654,812 11-20-2019 06:40 3e3d210f gb_ns245e2c32g1s1000hx.inp 4,081 11-18-2019 17:26 ada50edb gb_ns245e2c32g1s1000hx.out 655,529 11-20-2019 07:04 bea43c2f gb_ns245e2c32g1s1100hx.inp 4,081 11-18-2019 17:26 f69b28fa gb_ns245e2c32g1s1100hx.out 655,350 11-20-2019 07:11 020409c4 gb_ns245e2c32g1s1200hx.inp 4,081 11-18-2019 17:26 658648bb gb_ns245e2c32g1s1200hx.out 655,270 11-20-2019 06:40 8eb6400f gb_ns245e2c32g1s1300hx.inp 4,081 11-18-2019 17:26 23fd4cef gb_ns245e2c32g1s1300hx.out 654,344 11-20-2019 07:08 17d2efb6 gb_ns245e2c32g1s1400hx.inp 4,081 11-18-2019 17:26 52cfd884 gb_ns245e2c32g1s1400hx.out 655,122 11-20-2019 07:04 0449dc2d gb_ns245e2c32g1s1500hx.inp 4,081 11-18-2019 17:26 bfce0d23 gb_ns245e2c32g1s1500hx.out 655,162 11-20-2019 06:18 5973161c
\\v1.2\\gb\\ns325\\ (22) 7,086,673 11-20-2019 09:22 gb_ns325e2c32g1s0500hx.inp 4,029 11-18-2019 16:20 4af77ae5 gb_ns325e2c32g1s0500hx.out 507,242 11-20-2019 02:04 4bd803e7 gb_ns325e2c32g1s0600hx.inp 4,027 11-18-2019 16:20 4ada6940 gb_ns325e2c32g1s0600hx.out 653,946 11-20-2019 02:02 0a560c78 gb_ns325e2c32g1s0700hx.inp 4,027 11-18-2019 16:20 5d3a6dc7 gb_ns325e2c32g1s0700hx.out 653,328 11-20-2019 02:01 dad08b71 gb_ns325e2c32g1s0800hx.inp 4,027 11-18-2019 16:20 08f293e4 gb_ns325e2c32g1s0800hx.out 652,612 11-20-2019 02:00 bf058f36 gb_ns325e2c32g1s0900hx.inp 4,027 11-18-2019 16:20 4a855666 gb_ns325e2c32g1s0900hx.out 653,356 11-20-2019 02:00 458b4b52 gb_ns325e2c32g1s1000hx.inp 4,031 11-18-2019 16:21 393f6d29 gb_ns325e2c32g1s1000hx.out 653,707 11-20-2019 02:01 0b816f09 gb_ns325e2c32g1s1100hx.inp 4,031 11-18-2019 16:21 38cd7b38 gb_ns325e2c32g1s1100hx.out 653,857 11-20-2019 02:08 a0e5e6a6 gb_ns325e2c32g1s1200hx.inp 4,031 11-18-2019 16:21 e43abc4c gb_ns325e2c32g1s1200hx.out 653,716 11-20-2019 02:02 46b03468 gb_ns325e2c32g1s1300hx.inp 4,031 11-18-2019 16:21 3f494e1e gb_ns325e2c32g1s1300hx.out 653,678 11-20-2019 02:04 91a0449c gb_ns325e2c32g1s1400hx.inp 4,031 11-18-2019 16:21 7c015bff gb_ns325e2c32g1s1400hx.out 654,329 11-20-2019 02:08 6dd88d66 gb_ns325e2c32g1s1500hx.inp 4,031 11-18-2019 16:21 b8d92f70 gb_ns325e2c32g1s1500hx.out 652,579 11-20-2019 02:09 82501e0a
\\v1.2\\gc\\ (0) 47,398,413 11-18-2019 17:26
\\v1.2\\gc\\ha245\\ (18) 5,930,179 11-22-2019 12:48 gc_ha245e2c32g1s001vfio.inp 4,046 11-18-2019 02:29 f9bd4f27 gc_ha245e2c32g1s001vfio.out 654,594 11-18-2019 15:12 bd2ae166 gc_ha245e2c32g1s005vfio.inp 4,046 11-18-2019 02:29 2d25e7e0 gc_ha245e2c32g1s005vfio.out 654,742 11-18-2019 15:12 144787a1 gc_ha245e2c32g1s010vfio.inp 4,046 11-18-2019 02:29 4c642d38 gc_ha245e2c32g1s010vfio.out 654,606 11-18-2019 15:22 5f94bea0 gc_ha245e2c32g1s030vfio.inp 4,046 11-18-2019 02:29 9f0ce1b7 gc_ha245e2c32g1s030vfio.out 654,724 11-18-2019 15:55 dc6bce07 gc_ha245e2c32g1s050vfio.inp 4,046 11-18-2019 02:29 a0428b91 gc_ha245e2c32g1s050vfio.out 655,612 11-18-2019 16:13 3367b732 gc_ha245e2c32g1s070vfio.inp 4,046 11-18-2019 02:29 707dfa99 gc_ha245e2c32g1s070vfio.out 654,722 11-18-2019 16:26 4ae14ad8 gc_ha245e2c32g1s090vfio.inp 4,046 11-18-2019 02:30 189d8a70 gc_ha245e2c32g1s090vfio.out 654,841 11-18-2019 16:32 c0edc6c7 gc_ha245e2c32g1s095vfio.inp 4,046 11-18-2019 02:30 3ad7a1df gc_ha245e2c32g1s095vfio.out 655,062 11-18-2019 16:23 9dd07907 gc_ha245e2c32g1s100vfio.inp 4,046 11-18-2019 02:30 9cc28cdc gc_ha245e2c32g1s100vfio.out 654,862 11-18-2019 16:38 6619e9bc
\\v1.2\\gc\\ha325\\ (18) 5,920,873 11-22-2019 12:48 gc_ha325e2c32g1s001vfio.inp 3,991 11-18-2019 01:14 42c7e464 gc_ha325e2c32g1s001vfio.out 654,339 11-18-2019 05:18 ad70f661 gc_ha325e2c32g1s005vfio.inp 3,991 11-18-2019 01:14 28c6c2f7 gc_ha325e2c32g1s005vfio.out 653,309 11-18-2019 05:05 cc954f85 gc_ha325e2c32g1s010vfio.inp 3,991 11-18-2019 01:14 d1ffd765 gc_ha325e2c32g1s010vfio.out 654,405 11-18-2019 05:12 ff51f9a5 gc_ha325e2c32g1s030vfio.inp 3,991 11-18-2019 01:14 7a3a5661 gc_ha325e2c32g1s030vfio.out 653,998 11-18-2019 05:45 93e15848 gc_ha325e2c32g1s050vfio.inp 3,991 11-18-2019 01:14 5886cde5
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
148 of 190 gc_ha325e2c32g1s050vfio.out 653,522 11-18-2019 06:03 0560e5d8 gc_ha325e2c32g1s070vfio.inp 3,991 11-18-2019 01:14 0e5e029e gc_ha325e2c32g1s070vfio.out 654,140 11-18-2019 06:17 a81df48f gc_ha325e2c32g1s090vfio.inp 3,991 11-18-2019 01:14 f6ec92ca gc_ha325e2c32g1s090vfio.out 653,826 11-18-2019 06:26 b2afd02d gc_ha325e2c32g1s095vfio.inp 3,991 11-18-2019 01:14 791eb353 gc_ha325e2c32g1s095vfio.out 653,833 11-18-2019 06:23 e2905ea4 gc_ha325e2c32g1s100vfio.inp 3,991 11-18-2019 01:14 a8d7c58e gc_ha325e2c32g1s100vfio.out 653,582 11-18-2019 06:30 fd7b2d88
\\v1.2\\gc\\hs245\\ (18) 5,930,947 11-22-2019 12:48 gc_hs245e2c32g1s001vfi.inp 4,074 11-18-2019 14:54 b83544b7 gc_hs245e2c32g1s001vfi.out 654,951 11-19-2019 20:13 5e6c358f gc_hs245e2c32g1s005vfi.inp 4,074 11-18-2019 14:54 4e40e8f6 gc_hs245e2c32g1s005vfi.out 654,735 11-19-2019 20:02 4012d9a6 gc_hs245e2c32g1s010vfi.inp 4,074 11-18-2019 14:54 b6454f6b gc_hs245e2c32g1s010vfi.out 654,953 11-19-2019 20:13 c2b789cf gc_hs245e2c32g1s030vfi.inp 4,074 11-18-2019 14:55 adde9bd7 gc_hs245e2c32g1s030vfi.out 656,016 11-19-2019 20:17 126868b3 gc_hs245e2c32g1s050vfi.inp 4,074 11-18-2019 14:55 2dca8894 gc_hs245e2c32g1s050vfi.out 655,042 11-19-2019 20:29 091268f2 gc_hs245e2c32g1s070vfi.inp 4,074 11-18-2019 14:55 526159a0 gc_hs245e2c32g1s070vfi.out 655,305 11-19-2019 20:41 a23bc09a gc_hs245e2c32g1s090vfi.inp 4,074 11-18-2019 14:55 00692903 gc_hs245e2c32g1s090vfi.out 654,598 11-19-2019 20:39 cabb1aa9 gc_hs245e2c32g1s095vfi.inp 4,074 11-18-2019 14:55 9a729b9b gc_hs245e2c32g1s095vfi.out 654,168 11-19-2019 20:58 5d3e0377 gc_hs245e2c32g1s100vfi.inp 4,074 11-18-2019 14:55 8591e11f gc_hs245e2c32g1s100vfi.out 654,513 11-19-2019 21:05 4ab135e3
\\v1.2\\gc\\hs325\\ (18) 5,918,570 11-22-2019 12:48 gc_hs325e2c32g1s001vfi.inp 4,024 11-18-2019 13:06 a9ed19b9 gc_hs325e2c32g1s001vfi.out 653,323 11-19-2019 15:08 bc2af95e gc_hs325e2c32g1s005vfi.inp 4,024 11-18-2019 13:06 29aba489 gc_hs325e2c32g1s005vfi.out 652,791 11-19-2019 14:45 adb3b89c gc_hs325e2c32g1s010vfi.inp 4,024 11-18-2019 13:07 390719a7 gc_hs325e2c32g1s010vfi.out 653,955 11-19-2019 14:34 8dff1c4e gc_hs325e2c32g1s030vfi.inp 4,024 11-18-2019 13:07 523687de gc_hs325e2c32g1s030vfi.out 653,598 11-19-2019 14:54 0ca81839 gc_hs325e2c32g1s050vfi.inp 4,024 11-18-2019 13:07 faf76f21 gc_hs325e2c32g1s050vfi.out 653,358 11-19-2019 15:04 8cb63d4d gc_hs325e2c32g1s070vfi.inp 4,024 11-18-2019 13:07 3ffa1f39 gc_hs325e2c32g1s070vfi.out 652,878 11-19-2019 15:07 836463fa gc_hs325e2c32g1s090vfi.inp 4,024 11-18-2019 13:07 4a82d120 gc_hs325e2c32g1s090vfi.out 654,267 11-19-2019 15:11 3543e310 gc_hs325e2c32g1s095vfi.inp 4,024 11-18-2019 13:07 7b64e2b1 gc_hs325e2c32g1s095vfi.out 653,236 11-19-2019 15:23 ef529fa4 gc_hs325e2c32g1s100vfi.inp 4,024 11-18-2019 13:07 d4f29d99 gc_hs325e2c32g1s100vfi.out 654,948 11-19-2019 15:34 ea4e935d
\\v1.2\\gc\\na245\\ (18) 5,930,200 11-22-2019 12:48 gc_na245e2c32g1s001vfio.inp 4,073 11-18-2019 11:44 8a5bf663 gc_na245e2c32g1s001vfio.out 655,212 11-19-2019 07:15 98dc0a16 gc_na245e2c32g1s005vfio.inp 4,073 11-18-2019 11:44 3b27c357 gc_na245e2c32g1s005vfio.out 655,958 11-19-2019 07:10 22d218c4 gc_na245e2c32g1s010vfio.inp 4,073 11-18-2019 11:44 ed0fcff7 gc_na245e2c32g1s010vfio.out 655,762 11-19-2019 07:27 dc13d0f2 gc_na245e2c32g1s030vfio.inp 4,073 11-18-2019 11:44 02bb069b gc_na245e2c32g1s030vfio.out 654,663 11-19-2019 08:00 afe9ec8e gc_na245e2c32g1s050vfio.inp 4,073 11-18-2019 11:44 afa0ca35 gc_na245e2c32g1s050vfio.out 653,568 11-19-2019 08:22 a293f01b gc_na245e2c32g1s070vfio.inp 4,073 11-18-2019 11:45 10c9de0a gc_na245e2c32g1s070vfio.out 654,933 11-19-2019 08:31 6cb6d795 gc_na245e2c32g1s090vfio.inp 4,073 11-18-2019 11:45 a825c677 gc_na245e2c32g1s090vfio.out 654,396 11-19-2019 08:31 e2ce8057 gc_na245e2c32g1s095vfio.inp 4,073 11-18-2019 11:45 e2eeaea7 gc_na245e2c32g1s095vfio.out 654,391 11-19-2019 08:37 9669d063 gc_na245e2c32g1s100vfio.inp 4,073 11-18-2019 11:45 223f4370 gc_na245e2c32g1s100vfio.out 654,660 11-19-2019 08:33 69dcbae9
\\v1.2\\gc\\na325\\ (18) 5,920,460 11-22-2019 12:48 gc_na325e2c32g1s001vfio.inp 4,023 11-18-2019 10:40 880b4ba9 gc_na325e2c32g1s001vfio.out 654,404 11-18-2019 23:28 fee262bf gc_na325e2c32g1s005vfio.inp 4,023 11-18-2019 10:40 0236eec8 gc_na325e2c32g1s005vfio.out 655,109 11-18-2019 23:23 9dc907f1 gc_na325e2c32g1s010vfio.inp 4,023 11-18-2019 10:41 29c9d993 gc_na325e2c32g1s010vfio.out 654,265 11-18-2019 23:28 7e2667a5
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
149 of 190 gc_na325e2c32g1s030vfio.inp 4,023 11-18-2019 10:41 c35ccb1e gc_na325e2c32g1s030vfio.out 653,914 11-19-2019 00:08 c9adec16 gc_na325e2c32g1s050vfio.inp 4,023 11-18-2019 10:41 f81df1b0 gc_na325e2c32g1s050vfio.out 653,663 11-19-2019 00:28 ea99d31c gc_na325e2c32g1s070vfio.inp 4,023 11-18-2019 10:41 5ad2bf9d gc_na325e2c32g1s070vfio.out 652,697 11-19-2019 00:34 acf97155 gc_na325e2c32g1s090vfio.inp 4,023 11-18-2019 10:41 795f2277 gc_na325e2c32g1s090vfio.out 653,135 11-19-2019 00:43 dc7c8318 gc_na325e2c32g1s095vfio.inp 4,023 11-18-2019 10:41 17a05094 gc_na325e2c32g1s095vfio.out 653,057 11-19-2019 00:41 e697266c gc_na325e2c32g1s100vfio.inp 4,023 11-18-2019 10:41 958cb6e1 gc_na325e2c32g1s100vfio.out 654,009 11-19-2019 00:41 2adcec60
\\v1.2\\gc\\ns245\\ (18) 5,928,577 11-22-2019 12:48 gc_ns245e2c32g1s001vfi.inp 4,074 11-18-2019 17:26 0fd28efe gc_ns245e2c32g1s001vfi.out 654,307 11-20-2019 06:45 fcab45f3 gc_ns245e2c32g1s005vfi.inp 4,074 11-18-2019 17:26 f9a722bf gc_ns245e2c32g1s005vfi.out 653,659 11-20-2019 06:13 0d88d0ef gc_ns245e2c32g1s010vfi.inp 4,074 11-18-2019 17:26 01a28522 gc_ns245e2c32g1s010vfi.out 655,219 11-20-2019 06:20 8b470566 gc_ns245e2c32g1s030vfi.inp 4,074 11-18-2019 17:26 1a39519e gc_ns245e2c32g1s030vfi.out 653,840 11-20-2019 06:06 b7a7e1ac gc_ns245e2c32g1s050vfi.inp 4,074 11-18-2019 17:27 9a2d42dd gc_ns245e2c32g1s050vfi.out 655,088 11-20-2019 06:53 f01fc617 gc_ns245e2c32g1s070vfi.inp 4,074 11-18-2019 17:27 e58693e9 gc_ns245e2c32g1s070vfi.out 655,016 11-20-2019 07:02 508a8a84 gc_ns245e2c32g1s090vfi.inp 4,074 11-18-2019 17:27 b78ee34a gc_ns245e2c32g1s090vfi.out 655,162 11-20-2019 07:15 0121c9e2 gc_ns245e2c32g1s095vfi.inp 4,074 11-18-2019 17:27 2d9551d2 gc_ns245e2c32g1s095vfi.out 654,544 11-20-2019 07:09 04ca598d gc_ns245e2c32g1s100vfi.inp 4,074 11-18-2019 17:27 32762b56 gc_ns245e2c32g1s100vfi.out 655,076 11-20-2019 06:26 a22a7a3d
\\v1.2\\gc\\ns325\\ (18) 5,918,607 11-22-2019 12:48 gc_ns325e2c32g1s001vfi.inp 4,024 11-18-2019 16:21 a955b7f5 gc_ns325e2c32g1s001vfi.out 652,730 11-20-2019 01:36 d5267dca gc_ns325e2c32g1s005vfi.inp 4,024 11-18-2019 16:21 29130ac5 gc_ns325e2c32g1s005vfi.out 653,970 11-20-2019 01:27 6d416f18 gc_ns325e2c32g1s010vfi.inp 4,024 11-18-2019 16:21 39bfb7eb gc_ns325e2c32g1s010vfi.out 654,135 11-20-2019 01:14 9136074b gc_ns325e2c32g1s030vfi.inp 4,024 11-18-2019 16:21 528e2992 gc_ns325e2c32g1s030vfi.out 652,784 11-20-2019 01:25 c9e6713b gc_ns325e2c32g1s050vfi.inp 4,024 11-18-2019 16:21 fa4fc16d gc_ns325e2c32g1s050vfi.out 653,675 11-20-2019 01:51 0cec2fb1 gc_ns325e2c32g1s070vfi.inp 4,024 11-18-2019 16:22 3f42b175 gc_ns325e2c32g1s070vfi.out 653,872 11-20-2019 02:07 7fa4500a gc_ns325e2c32g1s090vfi.inp 4,024 11-18-2019 16:22 4a3a7f6c gc_ns325e2c32g1s090vfi.out 653,547 11-20-2019 02:11 84bd5f2b gc_ns325e2c32g1s095vfi.inp 4,024 11-18-2019 16:22 7bdc4cfd gc_ns325e2c32g1s095vfi.out 653,910 11-20-2019 02:15 318e138f gc_ns325e2c32g1s100vfi.inp 4,024 11-18-2019 16:22 d44a33d5 gc_ns325e2c32g1s100vfi.out 653,768 11-20-2019 02:00 141d8595
\\v1.2\\gd\\ (0) 43,442,629 11-18-2019 17:27
\\v1.2\\gd\\ha245\\ (18) 5,928,401 11-22-2019 12:48 gd_ha245e2c32g1s001vfio.inp 4,049 11-18-2019 02:30 625cbd3f gd_ha245e2c32g1s001vfio.out 654,994 11-18-2019 15:23 dfa65051 gd_ha245e2c32g1s005vfio.inp 4,049 11-18-2019 02:30 51791e0d gd_ha245e2c32g1s005vfio.out 655,859 11-18-2019 15:13 981be6b2 gd_ha245e2c32g1s010vfio.inp 4,049 11-18-2019 02:30 01258402 gd_ha245e2c32g1s010vfio.out 654,786 11-18-2019 15:27 ae83d4cf gd_ha245e2c32g1s030vfio.inp 4,049 11-18-2019 02:30 3d6bca3d gd_ha245e2c32g1s030vfio.out 654,843 11-18-2019 15:51 bf5183bb gd_ha245e2c32g1s050vfio.inp 4,049 11-18-2019 02:30 5b6e89e5 gd_ha245e2c32g1s050vfio.out 654,190 11-18-2019 16:07 36ec7d3b gd_ha245e2c32g1s070vfio.inp 4,049 11-18-2019 02:30 5d148f25 gd_ha245e2c32g1s070vfio.out 654,549 11-18-2019 16:17 ef633214 gd_ha245e2c32g1s090vfio.inp 4,049 11-18-2019 02:30 6ec05e3a gd_ha245e2c32g1s090vfio.out 653,761 11-18-2019 16:24 c5b19144 gd_ha245e2c32g1s095vfio.inp 4,049 11-18-2019 02:31 030b6cfb gd_ha245e2c32g1s095vfio.out 654,243 11-18-2019 16:36 d34f64dd gd_ha245e2c32g1s100vfio.inp 4,049 11-18-2019 02:31 0cb4a589 gd_ha245e2c32g1s100vfio.out 654,735 11-18-2019 16:36 ab6de1bb
\\v1.2\\gd\\ha325\\ (18) 5,917,129 11-22-2019 12:48
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
150 of 190 gd_ha325e2c32g1s001vfio.inp 3,994 11-18-2019 01:14 0b2c646c gd_ha325e2c32g1s001vfio.out 653,951 11-18-2019 05:21 c9ae9125 gd_ha325e2c32g1s005vfio.inp 3,994 11-18-2019 01:14 c2e2b883 gd_ha325e2c32g1s005vfio.out 653,645 11-18-2019 05:06 6cd013ad gd_ha325e2c32g1s010vfio.inp 3,994 11-18-2019 01:15 ce5b698a gd_ha325e2c32g1s010vfio.out 652,472 11-18-2019 05:25 8c3a5c6a gd_ha325e2c32g1s030vfio.inp 3,994 11-18-2019 01:15 b636cbbb gd_ha325e2c32g1s030vfio.out 653,866 11-18-2019 05:46 ce55edbc gd_ha325e2c32g1s050vfio.inp 3,994 11-18-2019 01:15 36bfed47 gd_ha325e2c32g1s050vfio.out 652,957 11-18-2019 06:05 ff3dbc91 gd_ha325e2c32g1s070vfio.inp 3,994 11-18-2019 01:15 e35b52cd gd_ha325e2c32g1s070vfio.out 654,020 11-18-2019 06:18 e7d2d7a3 gd_ha325e2c32g1s090vfio.inp 3,994 11-18-2019 01:15 2193720d gd_ha325e2c32g1s090vfio.out 653,794 11-18-2019 06:22 572503e4 gd_ha325e2c32g1s095vfio.inp 3,994 11-18-2019 01:15 96a4bdae gd_ha325e2c32g1s095vfio.out 653,414 11-18-2019 06:25 64360c04 gd_ha325e2c32g1s100vfio.inp 3,994 11-18-2019 01:15 b4c1f22c gd_ha325e2c32g1s100vfio.out 653,064 11-18-2019 06:32 31b72dbd
\\v1.2\\gd\\hs245\\ (18) 4,612,925 11-22-2019 12:48 gd_hs245e2c32g1s001vfi.inp 4,077 11-18-2019 14:55 4b3afa11 gd_hs245e2c32g1s001vfi.out 508,084 11-19-2019 20:39 b487b5b4 gd_hs245e2c32g1s005vfi.inp 4,077 11-18-2019 14:55 0b9dcf04 gd_hs245e2c32g1s005vfi.out 508,416 11-19-2019 20:15 d8d3a091 gd_hs245e2c32g1s010vfi.inp 4,077 11-18-2019 14:55 b0f62d7d gd_hs245e2c32g1s010vfi.out 509,263 11-19-2019 20:09 c2cf37de gd_hs245e2c32g1s030vfi.inp 4,077 11-18-2019 14:55 9bc78e18 gd_hs245e2c32g1s030vfi.out 508,346 11-19-2019 20:28 f13bcf47 gd_hs245e2c32g1s050vfi.inp 4,077 11-18-2019 14:56 c5714af8 gd_hs245e2c32g1s050vfi.out 508,327 11-19-2019 20:36 41ae0ab0 gd_hs245e2c32g1s070vfi.inp 4,077 11-18-2019 14:56 74650c71 gd_hs245e2c32g1s070vfi.out 509,343 11-19-2019 20:56 5196cbea gd_hs245e2c32g1s090vfi.inp 4,077 11-18-2019 14:56 31f8dc94 gd_hs245e2c32g1s090vfi.out 508,027 11-19-2019 20:41 b8b53a76 gd_hs245e2c32g1s095vfi.inp 4,077 11-18-2019 14:56 dcbbd3f3 gd_hs245e2c32g1s095vfi.out 507,547 11-19-2019 20:58 7ed7392e gd_hs245e2c32g1s100vfi.inp 4,077 11-18-2019 14:56 dadccb99 gd_hs245e2c32g1s100vfi.out 508,879 11-19-2019 20:55 007a2e69
\\v1.2\\gd\\hs325\\ (18) 5,919,827 11-22-2019 12:48 gd_hs325e2c32g1s001vfi.inp 4,027 11-18-2019 13:07 655d5361 gd_hs325e2c32g1s001vfi.out 653,613 11-19-2019 14:51 75a54ac5 gd_hs325e2c32g1s005vfi.inp 4,027 11-18-2019 13:07 4069e5ad gd_hs325e2c32g1s005vfi.out 654,332 11-19-2019 14:51 99ac0453 gd_hs325e2c32g1s010vfi.inp 4,027 11-18-2019 13:07 a50c3496 gd_hs325e2c32g1s010vfi.out 653,178 11-19-2019 14:44 2684995d gd_hs325e2c32g1s030vfi.inp 4,027 11-18-2019 13:07 ce0f5c47 gd_hs325e2c32g1s030vfi.out 653,710 11-19-2019 14:50 244b07c5 gd_hs325e2c32g1s050vfi.inp 4,027 11-18-2019 13:08 3906eb70 gd_hs325e2c32g1s050vfi.out 653,501 11-19-2019 15:10 3b5095c9 gd_hs325e2c32g1s070vfi.inp 4,027 11-18-2019 13:08 3bc85294 gd_hs325e2c32g1s070vfi.out 653,568 11-19-2019 15:18 c8d4c16b gd_hs325e2c32g1s090vfi.inp 4,027 11-18-2019 13:08 7b394e03 gd_hs325e2c32g1s090vfi.out 654,355 11-19-2019 15:26 ffb412c1 gd_hs325e2c32g1s095vfi.inp 4,027 11-18-2019 13:08 cd944063 gd_hs325e2c32g1s095vfi.out 654,053 11-19-2019 15:29 a33a3518 gd_hs325e2c32g1s100vfi.inp 4,027 11-18-2019 13:08 e5a73cb2 gd_hs325e2c32g1s100vfi.out 653,274 11-19-2019 15:33 d3864415
\\v1.2\\gd\\na245\\ (18) 4,613,807 11-22-2019 12:48 gd_na245e2c32g1s001vfio.inp 4,076 11-18-2019 11:45 d1157cce gd_na245e2c32g1s001vfio.out 508,639 11-19-2019 07:19 2842c569 gd_na245e2c32g1s005vfio.inp 4,076 11-18-2019 11:45 363ac026 gd_na245e2c32g1s005vfio.out 509,392 11-19-2019 07:13 2e7b49c4 gd_na245e2c32g1s010vfio.inp 4,076 11-18-2019 11:45 954aca42 gd_na245e2c32g1s010vfio.out 507,657 11-19-2019 07:30 22ac0512 gd_na245e2c32g1s030vfio.inp 4,076 11-18-2019 11:45 f0b28002 gd_na245e2c32g1s030vfio.out 508,963 11-19-2019 08:05 5337798d gd_na245e2c32g1s050vfio.inp 4,076 11-18-2019 11:45 9acd3764 gd_na245e2c32g1s050vfio.out 507,892 11-19-2019 08:27 1414c6d9 gd_na245e2c32g1s070vfio.inp 4,076 11-18-2019 11:45 2711a9fd gd_na245e2c32g1s070vfio.out 509,391 11-19-2019 08:31 6b2c922f gd_na245e2c32g1s090vfio.inp 4,076 11-18-2019 11:46 4a4dc59a gd_na245e2c32g1s090vfio.out 508,664 11-19-2019 08:39 b919f869 gd_na245e2c32g1s095vfio.inp 4,076 11-18-2019 11:46 39c0772e gd_na245e2c32g1s095vfio.out 508,425 11-19-2019 08:41 91bc2378 gd_na245e2c32g1s100vfio.inp 4,076 11-18-2019 11:46 eb0cf231 gd_na245e2c32g1s100vfio.out 508,100 11-19-2019 08:52 1d008c27
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
151 of 190
\\v1.2\\gd\\na325\\ (18) 4,602,401 11-22-2019 12:48 gd_na325e2c32g1s001vfio.inp 4,026 11-18-2019 10:41 18b952d5 gd_na325e2c32g1s001vfio.out 507,180 11-18-2019 23:30 25a4b815 gd_na325e2c32g1s005vfio.inp 4,026 11-18-2019 10:41 58f69e6b gd_na325e2c32g1s005vfio.out 507,887 11-18-2019 23:22 164b6fff gd_na325e2c32g1s010vfio.inp 4,026 11-18-2019 10:41 1f84c3da gd_na325e2c32g1s010vfio.out 507,722 11-18-2019 23:36 12e4ae87 gd_na325e2c32g1s030vfio.inp 4,026 11-18-2019 10:42 b80ac988 gd_na325e2c32g1s030vfio.out 506,593 11-19-2019 00:11 ef1958eb gd_na325e2c32g1s050vfio.inp 4,026 11-18-2019 10:42 79492f52 gd_na325e2c32g1s050vfio.out 507,901 11-19-2019 00:18 35f0bb0b gd_na325e2c32g1s070vfio.inp 4,026 11-18-2019 10:42 65d7eee3 gd_na325e2c32g1s070vfio.out 507,120 11-19-2019 00:31 11bac393 gd_na325e2c32g1s090vfio.inp 4,026 11-18-2019 10:42 6b174e92 gd_na325e2c32g1s090vfio.out 506,944 11-19-2019 00:47 13cae8bb gd_na325e2c32g1s095vfio.inp 4,026 11-18-2019 10:42 6a611e7c gd_na325e2c32g1s095vfio.out 507,260 11-19-2019 00:48 1d309f07 gd_na325e2c32g1s100vfio.inp 4,026 11-18-2019 10:42 3e4ec198 gd_na325e2c32g1s100vfio.out 507,560 11-19-2019 00:49 82ed3050
\\v1.2\\gd\\ns245\\ (18) 5,929,892 11-22-2019 12:48 gd_ns245e2c32g1s001vfi.inp 4,077 11-18-2019 17:27 1896b05f gd_ns245e2c32g1s001vfi.out 654,998 11-20-2019 06:59 2fe73fd6 gd_ns245e2c32g1s005vfi.inp 4,077 11-18-2019 17:27 5831854a gd_ns245e2c32g1s005vfi.out 655,795 11-20-2019 06:27 cf413417 gd_ns245e2c32g1s010vfi.inp 4,077 11-18-2019 17:27 e35a6733 gd_ns245e2c32g1s010vfi.out 654,800 11-20-2019 06:16 9be619a3 gd_ns245e2c32g1s030vfi.inp 4,077 11-18-2019 17:27 c86bc456 gd_ns245e2c32g1s030vfi.out 654,343 11-20-2019 06:17 518751b3 gd_ns245e2c32g1s050vfi.inp 4,077 11-18-2019 17:27 96dd00b6 gd_ns245e2c32g1s050vfi.out 654,409 11-20-2019 06:45 d7d0af04 gd_ns245e2c32g1s070vfi.inp 4,077 11-18-2019 17:27 27c9463f gd_ns245e2c32g1s070vfi.out 654,606 11-20-2019 06:31 a992f6c9 gd_ns245e2c32g1s090vfi.inp 4,077 11-18-2019 17:28 625496da gd_ns245e2c32g1s090vfi.out 655,082 11-20-2019 06:46 8db4f22c gd_ns245e2c32g1s095vfi.inp 4,077 11-18-2019 17:28 8f1799bd gd_ns245e2c32g1s095vfi.out 654,353 11-20-2019 06:36 a6760fef gd_ns245e2c32g1s100vfi.inp 4,077 11-18-2019 17:28 897081d7 gd_ns245e2c32g1s100vfi.out 654,813 11-20-2019 06:32 15b4d509
\\v1.2\\gd\\ns325\\ (18) 5,918,247 11-22-2019 12:48 gd_ns325e2c32g1s001vfi.inp 4,027 11-18-2019 16:22 ca7f39b5 gd_ns325e2c32g1s001vfi.out 653,817 11-20-2019 01:47 8de82565 gd_ns325e2c32g1s005vfi.inp 4,027 11-18-2019 16:22 ef4b8f79 gd_ns325e2c32g1s005vfi.out 654,453 11-20-2019 01:17 fdbdc500 gd_ns325e2c32g1s010vfi.inp 4,027 11-18-2019 16:22 0a2e5e42 gd_ns325e2c32g1s010vfi.out 653,460 11-20-2019 01:18 004f8af9 gd_ns325e2c32g1s030vfi.inp 4,027 11-18-2019 16:22 612d3693 gd_ns325e2c32g1s030vfi.out 653,645 11-20-2019 01:31 50ee5421 gd_ns325e2c32g1s050vfi.inp 4,027 11-18-2019 16:22 962481a4 gd_ns325e2c32g1s050vfi.out 653,391 11-20-2019 01:44 71408100 gd_ns325e2c32g1s070vfi.inp 4,027 11-18-2019 16:23 94ea3840 gd_ns325e2c32g1s070vfi.out 653,402 11-20-2019 02:02 ace9cba1 gd_ns325e2c32g1s090vfi.inp 4,027 11-18-2019 16:23 d41b24d7 gd_ns325e2c32g1s090vfi.out 653,359 11-20-2019 02:24 48115f76 gd_ns325e2c32g1s095vfi.inp 4,027 11-18-2019 16:23 62b62ab7 gd_ns325e2c32g1s095vfi.out 653,125 11-20-2019 02:05 49d23139 gd_ns325e2c32g1s100vfi.inp 4,027 11-18-2019 16:23 4a855666 gd_ns325e2c32g1s100vfi.out 653,352 11-20-2019 02:27 2829c92b
\\v1.2\\ge\\ (0) 28,768,764 11-18-2019 15:33
\\v1.2\\ge\\ha245\\ (22) 7,218,517 11-18-2019 20:33 ge_ha245e2c32g1s0500hx.inp 3,731 11-18-2019 09:51 91e8ddc4 ge_ha245e2c32g1s0500hx.out 652,326 11-18-2019 16:36 aa5e0be1 ge_ha245e2c32g1s0600hx.inp 3,732 11-18-2019 09:52 70b0549b ge_ha245e2c32g1s0600hx.out 654,105 11-18-2019 16:31 67860ac8 ge_ha245e2c32g1s0700hx.inp 3,732 11-18-2019 09:52 51cad875 ge_ha245e2c32g1s0700hx.out 651,699 11-18-2019 16:29 1cadfabe ge_ha245e2c32g1s0800hx.inp 3,732 11-18-2019 09:52 0ef342e8 ge_ha245e2c32g1s0800hx.out 652,140 11-18-2019 16:44 382dfb2a ge_ha245e2c32g1s0900hx.inp 3,732 11-18-2019 09:52 9e3b1625 ge_ha245e2c32g1s0900hx.out 652,727 11-18-2019 16:43 eb291b9f ge_ha245e2c32g1s1000hx.inp 3,736 11-18-2019 09:52 531dbf87 ge_ha245e2c32g1s1000hx.out 652,263 11-18-2019 16:41 22b98498
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
152 of 190 ge_ha245e2c32g1s1100hx.inp 3,736 11-18-2019 09:52 fed699c8 ge_ha245e2c32g1s1100hx.out 652,444 11-18-2019 16:48 b76b9367 ge_ha245e2c32g1s1200hx.inp 3,736 11-18-2019 09:52 1c197beb ge_ha245e2c32g1s1200hx.out 652,975 11-18-2019 16:34 dc81715b ge_ha245e2c32g1s1300hx.inp 3,736 11-18-2019 09:52 e0cc7fd4 ge_ha245e2c32g1s1300hx.out 652,325 11-18-2019 16:35 d7a4e84d ge_ha245e2c32g1s1400hx.inp 3,736 11-18-2019 09:52 4bb9cd08 ge_ha245e2c32g1s1400hx.out 652,195 11-18-2019 16:35 2d7349a8 ge_ha245e2c32g1s1500hx.inp 3,736 11-18-2019 09:52 fdf40ee0 ge_ha245e2c32g1s1500hx.out 652,243 11-18-2019 16:52 ef779621
\\v1.2\\ge\\ha325\\ (22) 7,239,585 11-18-2019 20:33 ge_ha325e2c32g1s0500hx.inp 3,908 11-18-2019 01:22 e684ea03 ge_ha325e2c32g1s0500hx.out 654,381 11-18-2019 06:41 b29bb61f ge_ha325e2c32g1s0600hx.inp 3,908 11-18-2019 01:22 8874f9ae ge_ha325e2c32g1s0600hx.out 653,847 11-18-2019 07:02 1217198a ge_ha325e2c32g1s0700hx.inp 3,908 11-18-2019 01:22 07af4dd1 ge_ha325e2c32g1s0700hx.out 654,514 11-18-2019 06:34 030ae8f4 ge_ha325e2c32g1s0800hx.inp 3,908 11-18-2019 01:22 a110412b ge_ha325e2c32g1s0800hx.out 654,416 11-18-2019 06:56 b269ff14 ge_ha325e2c32g1s0900hx.inp 3,908 11-18-2019 01:22 6d00ac7d ge_ha325e2c32g1s0900hx.out 654,176 11-18-2019 06:59 52a83450 ge_ha325e2c32g1s1000hx.inp 3,912 11-18-2019 01:22 2111267c ge_ha325e2c32g1s1000hx.out 654,964 11-18-2019 06:58 7ba57cfb ge_ha325e2c32g1s1100hx.inp 3,912 11-18-2019 01:22 c912ef7a ge_ha325e2c32g1s1100hx.out 654,507 11-18-2019 06:52 cc8118bc ge_ha325e2c32g1s1200hx.inp 3,912 11-18-2019 01:22 e95cfe0f ge_ha325e2c32g1s1200hx.out 653,843 11-18-2019 06:53 10660a26 ge_ha325e2c32g1s1300hx.inp 3,912 11-18-2019 01:23 f36745d7 ge_ha325e2c32g1s1300hx.out 653,234 11-18-2019 06:49 c1dd4f2b ge_ha325e2c32g1s1400hx.inp 3,912 11-18-2019 01:23 53dd4379 ge_ha325e2c32g1s1400hx.out 654,210 11-18-2019 06:47 975c503f ge_ha325e2c32g1s1500hx.inp 3,911 11-18-2019 01:23 193f0d7d ge_ha325e2c32g1s1500hx.out 654,482 11-18-2019 06:44 4ab8c8d1
\\v1.2\\ge\\na245\\ (22) 7,070,629 11-20-2019 09:22 ge_na245e2c32g1s0500hx.inp 3,731 11-18-2019 12:02 8f0d5c79 ge_na245e2c32g1s0500hx.out 505,676 11-19-2019 08:45 066b3b0a ge_na245e2c32g1s0600hx.inp 3,732 11-18-2019 12:02 34ebb5d1 ge_na245e2c32g1s0600hx.out 652,622 11-19-2019 08:46 99527a94 ge_na245e2c32g1s0700hx.inp 3,732 11-18-2019 12:02 1591393f ge_na245e2c32g1s0700hx.out 652,194 11-19-2019 08:41 90c6dfc1 ge_na245e2c32g1s0800hx.inp 3,732 11-18-2019 12:02 4aa8a3a2 ge_na245e2c32g1s0800hx.out 652,691 11-19-2019 08:42 8c4f9206 ge_na245e2c32g1s0900hx.inp 3,732 11-18-2019 12:02 da60f76f ge_na245e2c32g1s0900hx.out 651,981 11-19-2019 08:41 629ecf75 ge_na245e2c32g1s1000hx.inp 3,736 11-18-2019 12:02 ea725e5e ge_na245e2c32g1s1000hx.out 652,173 11-19-2019 08:42 9ad1788e ge_na245e2c32g1s1100hx.inp 3,736 11-18-2019 12:02 47b97811 ge_na245e2c32g1s1100hx.out 652,089 11-19-2019 08:42 89bb61bb ge_na245e2c32g1s1200hx.inp 3,736 11-18-2019 12:02 a5769a32 ge_na245e2c32g1s1200hx.out 652,818 11-19-2019 08:42 7d17de6f ge_na245e2c32g1s1300hx.inp 3,736 11-18-2019 12:02 59a39e0d ge_na245e2c32g1s1300hx.out 652,055 11-19-2019 08:57 5ae7a9c9 ge_na245e2c32g1s1400hx.inp 3,736 11-18-2019 12:02 f2d62cd1 ge_na245e2c32g1s1400hx.out 653,133 11-19-2019 08:49 4e614e0c ge_na245e2c32g1s1500hx.inp 3,736 11-18-2019 12:02 449bef39 ge_na245e2c32g1s1500hx.out 652,122 11-19-2019 08:37 c87789bc
\\v1.2\\ge\\na325\\ (22) 7,240,033 11-20-2019 09:22 ge_na325e2c32g1s0500hx.inp 3,940 11-18-2019 10:57 9048f9f4 ge_na325e2c32g1s0500hx.out 654,044 11-19-2019 00:59 e5ff9584 ge_na325e2c32g1s0600hx.inp 3,940 11-18-2019 10:57 aeba2778 ge_na325e2c32g1s0600hx.out 655,130 11-19-2019 00:57 055c2762 ge_na325e2c32g1s0700hx.inp 3,940 11-18-2019 10:57 9144dea2 ge_na325e2c32g1s0700hx.out 653,858 11-19-2019 00:57 53e15bf1 ge_na325e2c32g1s0800hx.inp 3,940 11-18-2019 10:57 af00eed2 ge_na325e2c32g1s0800hx.out 653,951 11-19-2019 00:43 9cfedd82 ge_na325e2c32g1s0900hx.inp 3,940 11-18-2019 10:57 f743b750 ge_na325e2c32g1s0900hx.out 653,968 11-19-2019 01:00 8ef437f4 ge_na325e2c32g1s1000hx.inp 3,944 11-18-2019 10:57 9621cbb1 ge_na325e2c32g1s1000hx.out 653,442 11-19-2019 01:01 7f8fd1f7 ge_na325e2c32g1s1100hx.inp 3,944 11-18-2019 10:57 5677846c ge_na325e2c32g1s1100hx.out 654,267 11-19-2019 00:54 dd414042 ge_na325e2c32g1s1200hx.inp 3,944 11-18-2019 10:57 b1769d8a ge_na325e2c32g1s1200hx.out 654,744 11-19-2019 00:58 ab4f514c ge_na325e2c32g1s1300hx.inp 3,944 11-18-2019 10:57 8a69a250 ge_na325e2c32g1s1300hx.out 653,947 11-19-2019 00:54 c841a848
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
153 of 190 ge_na325e2c32g1s1400hx.inp 3,944 11-18-2019 10:58 1913951f ge_na325e2c32g1s1400hx.out 654,449 11-19-2019 01:03 34768d6b ge_na325e2c32g1s1500hx.inp 3,943 11-18-2019 10:58 84736804 ge_na325e2c32g1s1500hx.out 654,870 11-19-2019 01:00 bd5d268e
\\v1.2\\gf\\ (0) 26,285,618 11-18-2019 15:33
\\v1.2\\gf\\ha245\\ (22) 7,218,005 11-18-2019 20:33 gf_ha245e2c32g1s0500hx.inp 3,736 11-18-2019 09:52 162e086d gf_ha245e2c32g1s0500hx.out 652,667 11-18-2019 16:54 dfa0896e gf_ha245e2c32g1s0600hx.inp 3,737 11-18-2019 09:53 9e5dae52 gf_ha245e2c32g1s0600hx.out 652,133 11-18-2019 16:44 10abab61 gf_ha245e2c32g1s0700hx.inp 3,737 11-18-2019 09:53 ca0009ee gf_ha245e2c32g1s0700hx.out 652,250 11-18-2019 16:42 ad470ebc gf_ha245e2c32g1s0800hx.inp 3,737 11-18-2019 09:53 a2090cc4 gf_ha245e2c32g1s0800hx.out 652,422 11-18-2019 16:38 bd25cd2c gf_ha245e2c32g1s0900hx.inp 3,735 11-18-2019 09:53 7e671032 gf_ha245e2c32g1s0900hx.out 652,425 11-18-2019 16:41 24f41e5e gf_ha245e2c32g1s1000hx.inp 3,739 11-18-2019 09:53 d140773c gf_ha245e2c32g1s1000hx.out 652,158 11-18-2019 16:41 1d51dca8 gf_ha245e2c32g1s1100hx.inp 3,739 11-18-2019 09:53 5fd2ab58 gf_ha245e2c32g1s1100hx.out 652,132 11-18-2019 16:52 895cbb3b gf_ha245e2c32g1s1200hx.inp 3,739 11-18-2019 09:53 542a3999 gf_ha245e2c32g1s1200hx.out 652,893 11-18-2019 16:46 fea36f0e gf_ha245e2c32g1s1300hx.inp 3,739 11-18-2019 09:53 daef331f gf_ha245e2c32g1s1300hx.out 652,329 11-18-2019 16:45 482f55f7 gf_ha245e2c32g1s1400hx.inp 3,739 11-18-2019 09:53 4ebb7121 gf_ha245e2c32g1s1400hx.out 652,594 11-18-2019 16:45 52415f8f gf_ha245e2c32g1s1500hx.inp 3,739 11-18-2019 09:53 878ae3d5 gf_ha245e2c32g1s1500hx.out 652,886 11-18-2019 16:55 5b706d0a
\\v1.2\\gf\\ha325\\ (22) 7,240,778 11-18-2019 20:33 gf_ha325e2c32g1s0500hx.inp 3,913 11-18-2019 01:23 dc1958b4 gf_ha325e2c32g1s0500hx.out 653,902 11-18-2019 07:00 7b93c15e gf_ha325e2c32g1s0600hx.inp 3,911 11-18-2019 01:23 dd85570d gf_ha325e2c32g1s0600hx.out 653,916 11-18-2019 06:43 db91412e gf_ha325e2c32g1s0700hx.inp 3,911 11-18-2019 01:23 748cf258 gf_ha325e2c32g1s0700hx.out 654,006 11-18-2019 06:43 e4f31af1 gf_ha325e2c32g1s0800hx.inp 3,911 11-18-2019 01:23 176f1e46 gf_ha325e2c32g1s0800hx.out 654,092 11-18-2019 06:45 e1d60fa2 gf_ha325e2c32g1s0900hx.inp 3,911 11-18-2019 01:23 b53cead4 gf_ha325e2c32g1s0900hx.out 653,390 11-18-2019 06:44 6054408e gf_ha325e2c32g1s1000hx.inp 3,915 11-18-2019 01:23 870d79d9 gf_ha325e2c32g1s1000hx.out 654,449 11-18-2019 06:45 5e95cb55 gf_ha325e2c32g1s1100hx.inp 3,915 11-18-2019 01:23 0f90b6ec gf_ha325e2c32g1s1100hx.out 654,948 11-18-2019 06:52 4b3a317b gf_ha325e2c32g1s1200hx.inp 3,915 11-18-2019 01:23 cac42639 gf_ha325e2c32g1s1200hx.out 655,294 11-18-2019 06:59 d81285dd gf_ha325e2c32g1s1300hx.inp 3,915 11-18-2019 01:23 afe9bb16 gf_ha325e2c32g1s1300hx.out 653,984 11-18-2019 06:42 dbe172fc gf_ha325e2c32g1s1400hx.inp 3,915 11-18-2019 01:24 757319bd gf_ha325e2c32g1s1400hx.out 654,416 11-18-2019 06:48 781e286b gf_ha325e2c32g1s1500hx.inp 3,915 11-18-2019 01:24 a826eaec gf_ha325e2c32g1s1500hx.out 655,334 11-18-2019 07:01 0fa658ba
\\v1.2\\gf\\na245\\ (22) 5,609,415 11-20-2019 09:22 gf_na245e2c32g1s0500hx.inp 3,736 11-18-2019 12:03 3c8832a5 gf_na245e2c32g1s0500hx.out 505,736 11-19-2019 08:52 ce0312d0 gf_na245e2c32g1s0600hx.inp 3,737 11-18-2019 12:03 fa5d8910 gf_na245e2c32g1s0600hx.out 506,559 11-19-2019 08:47 4aaded8b gf_na245e2c32g1s0700hx.inp 3,737 11-18-2019 12:03 ae002eac gf_na245e2c32g1s0700hx.out 505,751 11-19-2019 08:47 afb3a9ac gf_na245e2c32g1s0800hx.inp 3,737 11-18-2019 12:03 c6092b86 gf_na245e2c32g1s0800hx.out 505,416 11-19-2019 08:44 f9471270 gf_na245e2c32g1s0900hx.inp 3,735 11-18-2019 12:03 f65ff418 gf_na245e2c32g1s0900hx.out 506,868 11-19-2019 08:56 5f1547a3 gf_na245e2c32g1s1000hx.inp 3,739 11-18-2019 12:03 879961f7 gf_na245e2c32g1s1000hx.out 506,922 11-19-2019 08:51 c399200a gf_na245e2c32g1s1100hx.inp 3,739 11-18-2019 12:03 090bbd93 gf_na245e2c32g1s1100hx.out 505,960 11-19-2019 08:46 c49c2a39 gf_na245e2c32g1s1200hx.inp 3,739 11-18-2019 12:03 02f32f52 gf_na245e2c32g1s1200hx.out 506,312 11-19-2019 08:50 040c1ce2 gf_na245e2c32g1s1300hx.inp 3,739 11-18-2019 12:03 8c3625d4 gf_na245e2c32g1s1300hx.out 506,648 11-19-2019 08:44 aa1499b4 gf_na245e2c32g1s1400hx.inp 3,739 11-18-2019 12:03 186267ea gf_na245e2c32g1s1400hx.out 505,935 11-19-2019 08:53 7a6c4421 gf_na245e2c32g1s1500hx.inp 3,739 11-18-2019 12:03 d153f51e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
154 of 190 gf_na245e2c32g1s1500hx.out 506,192 11-19-2019 08:57 d715e4c3
\\v1.2\\gf\\na325\\ (22) 6,217,420 11-20-2019 09:22 gf_na325e2c32g1s0500hx.inp 3,945 11-18-2019 10:58 712d7dc7 gf_na325e2c32g1s0500hx.out 507,854 11-19-2019 01:04 55f402e5 gf_na325e2c32g1s0600hx.inp 3,943 11-18-2019 10:58 061de02d gf_na325e2c32g1s0600hx.out 507,893 11-19-2019 01:08 0635a161 gf_na325e2c32g1s0700hx.inp 3,943 11-18-2019 10:58 7e743f4c gf_na325e2c32g1s0700hx.out 508,491 11-19-2019 01:00 52b4e084 gf_na325e2c32g1s0800hx.inp 3,943 11-18-2019 10:58 a8a91ff7 gf_na325e2c32g1s0800hx.out 507,583 11-19-2019 01:01 23644d48 gf_na325e2c32g1s0900hx.inp 3,943 11-18-2019 10:58 f2b11def gf_na325e2c32g1s0900hx.out 507,952 11-19-2019 00:59 9eaa0d5f gf_na325e2c32g1s1000hx.inp 3,947 11-18-2019 10:58 5f55b894 gf_na325e2c32g1s1000hx.out 507,506 11-19-2019 00:56 e5b3849e gf_na325e2c32g1s1100hx.inp 3,947 11-18-2019 10:58 20cc37ee gf_na325e2c32g1s1100hx.out 508,282 11-19-2019 01:00 6066a7e3 gf_na325e2c32g1s1200hx.inp 3,947 11-18-2019 10:58 3477775c gf_na325e2c32g1s1200hx.out 654,608 11-19-2019 00:58 6701cf7d gf_na325e2c32g1s1300hx.inp 3,947 11-18-2019 10:58 313287a2 gf_na325e2c32g1s1300hx.out 654,445 11-19-2019 01:01 7b350a8f gf_na325e2c32g1s1400hx.inp 3,947 11-18-2019 10:59 1eb15aaf gf_na325e2c32g1s1400hx.out 655,124 11-19-2019 01:00 e3b0ccdf gf_na325e2c32g1s1500hx.inp 3,947 11-18-2019 10:59 be61059c gf_na325e2c32g1s1500hx.out 654,283 11-19-2019 01:02 da576f15
\\v1.2\\gg\\ (0) 23,666,910 11-18-2019 15:33
\\v1.2\\gg\\ha245\\ (18) 5,907,109 11-22-2019 12:48 gg_ha245e2c32g1s001vfio.inp 3,732 11-18-2019 09:53 a65b37d3 gg_ha245e2c32g1s001vfio.out 652,681 11-18-2019 17:29 03781715 gg_ha245e2c32g1s005vfio.inp 3,732 11-18-2019 09:53 d1ce5a7a gg_ha245e2c32g1s005vfio.out 652,761 11-18-2019 16:48 c5cb3e70 gg_ha245e2c32g1s010vfio.inp 3,732 11-18-2019 09:54 21363a6a gg_ha245e2c32g1s010vfio.out 652,129 11-18-2019 16:30 6bff5d73 gg_ha245e2c32g1s030vfio.inp 3,732 11-18-2019 09:54 8e0d08d4 gg_ha245e2c32g1s030vfio.out 652,867 11-18-2019 16:43 b5f5f911 gg_ha245e2c32g1s050vfio.inp 3,732 11-18-2019 09:54 75cb03fc gg_ha245e2c32g1s050vfio.out 652,883 11-18-2019 16:56 d85efd1b gg_ha245e2c32g1s070vfio.inp 3,732 11-18-2019 09:54 4dbc2d36 gg_ha245e2c32g1s070vfio.out 652,507 11-18-2019 16:46 e1ae39ba gg_ha245e2c32g1s090vfio.inp 3,732 11-18-2019 09:54 c00baa1b gg_ha245e2c32g1s090vfio.out 652,576 11-18-2019 17:09 a49947d5 gg_ha245e2c32g1s095vfio.inp 3,732 11-18-2019 09:54 f45bdfc7 gg_ha245e2c32g1s095vfio.out 652,389 11-18-2019 17:10 24b916dd gg_ha245e2c32g1s100vfio.inp 3,732 11-18-2019 09:54 9e3b1625 gg_ha245e2c32g1s100vfio.out 652,728 11-18-2019 17:17 0c873bd5
\\v1.2\\gg\\ha325\\ (18) 5,926,274 11-22-2019 12:48 gg_ha325e2c32g1s001vfio.inp 3,908 11-18-2019 01:24 1b2c7d8c gg_ha325e2c32g1s001vfio.out 654,532 11-18-2019 07:28 3697c218 gg_ha325e2c32g1s005vfio.inp 3,908 11-18-2019 01:24 0f36f393 gg_ha325e2c32g1s005vfio.out 654,693 11-18-2019 06:39 785389b0 gg_ha325e2c32g1s010vfio.inp 3,908 11-18-2019 01:24 4ae31ac7 gg_ha325e2c32g1s010vfio.out 654,807 11-18-2019 06:17 0c0255f5 gg_ha325e2c32g1s030vfio.inp 3,908 11-18-2019 01:24 34ab607e gg_ha325e2c32g1s030vfio.out 654,670 11-18-2019 06:26 d7bcfbd3 gg_ha325e2c32g1s050vfio.inp 3,908 11-18-2019 01:24 815111c2 gg_ha325e2c32g1s050vfio.out 654,599 11-18-2019 06:22 b8dfb96a gg_ha325e2c32g1s070vfio.inp 3,908 11-18-2019 01:24 66d88273 gg_ha325e2c32g1s070vfio.out 654,862 11-18-2019 06:30 417202c6 gg_ha325e2c32g1s090vfio.inp 3,908 11-18-2019 01:24 81936022 gg_ha325e2c32g1s090vfio.out 654,621 11-18-2019 06:44 3fbac2b1 gg_ha325e2c32g1s095vfio.inp 3,908 11-18-2019 01:24 0dd92cc7 gg_ha325e2c32g1s095vfio.out 654,140 11-18-2019 06:43 1d994864 gg_ha325e2c32g1s100vfio.inp 3,908 11-18-2019 01:25 6d00ac7d gg_ha325e2c32g1s100vfio.out 654,178 11-18-2019 07:02 277a3392
\\v1.2\\gg\\na245\\ (18) 5,905,824 11-22-2019 12:48 gg_na245e2c32g1s001vfio.inp 3,732 11-18-2019 12:04 e200d699 gg_na245e2c32g1s001vfio.out 652,714 11-19-2019 09:40 41aeffc9 gg_na245e2c32g1s005vfio.inp 3,732 11-18-2019 12:04 9595bb30 gg_na245e2c32g1s005vfio.out 653,098 11-19-2019 08:32 192da32d gg_na245e2c32g1s010vfio.inp 3,732 11-18-2019 12:04 656ddb20 gg_na245e2c32g1s010vfio.out 652,257 11-19-2019 08:16 ad5acb9f gg_na245e2c32g1s030vfio.inp 3,732 11-18-2019 12:04 ca56e99e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
155 of 190 gg_na245e2c32g1s030vfio.out 652,982 11-19-2019 08:30 810186ae gg_na245e2c32g1s050vfio.inp 3,732 11-18-2019 12:04 3190e2b6 gg_na245e2c32g1s050vfio.out 652,236 11-19-2019 08:37 90f5b11c gg_na245e2c32g1s070vfio.inp 3,732 11-18-2019 12:04 09e7cc7c gg_na245e2c32g1s070vfio.out 652,595 11-19-2019 08:46 53040c46 gg_na245e2c32g1s090vfio.inp 3,732 11-18-2019 12:04 84504b51 gg_na245e2c32g1s090vfio.out 652,560 11-19-2019 08:51 15a44f59 gg_na245e2c32g1s095vfio.inp 3,732 11-18-2019 12:04 b0003e8d gg_na245e2c32g1s095vfio.out 651,811 11-19-2019 08:50 d2203eea gg_na245e2c32g1s100vfio.inp 3,732 11-18-2019 12:04 da60f76f gg_na245e2c32g1s100vfio.out 651,983 11-19-2019 08:52 88faa11b
\\v1.2\\gg\\na325\\ (18) 5,927,703 11-22-2019 12:48 gg_na325e2c32g1s001vfio.inp 3,940 11-18-2019 10:59 93e2e057 gg_na325e2c32g1s001vfio.out 655,132 11-19-2019 01:49 0b60d4b9 gg_na325e2c32g1s005vfio.inp 3,940 11-18-2019 10:59 2c782246 gg_na325e2c32g1s005vfio.out 654,857 11-19-2019 00:57 58945f48 gg_na325e2c32g1s010vfio.inp 3,940 11-18-2019 10:59 1364771c gg_na325e2c32g1s010vfio.out 655,297 11-19-2019 00:23 4343cf03 gg_na325e2c32g1s030vfio.inp 3,940 11-18-2019 10:59 7401a66f gg_na325e2c32g1s030vfio.out 654,246 11-19-2019 00:33 2d787ae3 gg_na325e2c32g1s050vfio.inp 3,940 11-18-2019 10:59 98f73976 gg_na325e2c32g1s050vfio.out 655,437 11-19-2019 00:44 696e8fcb gg_na325e2c32g1s070vfio.inp 3,940 11-18-2019 10:59 925c5a35 gg_na325e2c32g1s070vfio.out 654,424 11-19-2019 00:54 49cd07ef gg_na325e2c32g1s090vfio.inp 3,940 11-18-2019 10:59 0b9ad881 gg_na325e2c32g1s090vfio.out 655,243 11-19-2019 01:00 9484899d gg_na325e2c32g1s095vfio.inp 3,940 11-18-2019 10:59 05868d68 gg_na325e2c32g1s095vfio.out 653,636 11-19-2019 00:59 8a76580a gg_na325e2c32g1s100vfio.inp 3,940 11-18-2019 11:00 f743b750 gg_na325e2c32g1s100vfio.out 653,971 11-19-2019 00:59 b5e92a26
\\v1.2\\gh\\ (0) 21,028,227 11-18-2019 15:34
\\v1.2\\gh\\ha245\\ (18) 5,907,240 11-22-2019 12:48 gh_ha245e2c32g1s001vfio.inp 3,735 11-18-2019 09:54 b73a9bc5 gh_ha245e2c32g1s001vfio.out 652,533 11-18-2019 18:17 5117aebb gh_ha245e2c32g1s005vfio.inp 3,735 11-18-2019 09:54 5fe07166 gh_ha245e2c32g1s005vfio.out 652,678 11-18-2019 16:59 4d0b28fd gh_ha245e2c32g1s010vfio.inp 3,735 11-18-2019 09:54 966d939a gh_ha245e2c32g1s010vfio.out 653,496 11-18-2019 16:51 1378fbac gh_ha245e2c32g1s030vfio.inp 3,735 11-18-2019 09:55 8082a8c8 gh_ha245e2c32g1s030vfio.out 651,796 11-18-2019 16:50 38fc036d gh_ha245e2c32g1s050vfio.inp 3,735 11-18-2019 09:55 c8fd14ee gh_ha245e2c32g1s050vfio.out 652,857 11-18-2019 17:07 08c1b785 gh_ha245e2c32g1s070vfio.inp 3,735 11-18-2019 09:55 f61223a7 gh_ha245e2c32g1s070vfio.out 652,768 11-18-2019 17:09 a1df2280 gh_ha245e2c32g1s090vfio.inp 3,735 11-18-2019 09:55 b160380f gh_ha245e2c32g1s090vfio.out 652,083 11-18-2019 17:22 f2c73cb7 gh_ha245e2c32g1s095vfio.inp 3,735 11-18-2019 09:55 571f9127 gh_ha245e2c32g1s095vfio.out 652,986 11-18-2019 17:27 65b137fd gh_ha245e2c32g1s100vfio.inp 3,735 11-18-2019 09:55 7e671032 gh_ha245e2c32g1s100vfio.out 652,428 11-18-2019 17:32 29dec9e9
\\v1.2\\gh\\ha325\\ (18) 5,922,609 11-22-2019 12:48 gh_ha325e2c32g1s001vfio.inp 3,911 11-18-2019 01:25 6422efd2 gh_ha325e2c32g1s001vfio.out 654,624 11-18-2019 07:07 c582e4a7 gh_ha325e2c32g1s005vfio.inp 3,911 11-18-2019 01:25 7856ff13 gh_ha325e2c32g1s005vfio.out 654,551 11-18-2019 06:26 d6e2c347 gh_ha325e2c32g1s010vfio.inp 3,911 11-18-2019 01:25 afc21acc gh_ha325e2c32g1s010vfio.out 653,639 11-18-2019 06:07 bcffbb3e gh_ha325e2c32g1s030vfio.inp 3,911 11-18-2019 01:25 e14c5700 gh_ha325e2c32g1s030vfio.out 654,244 11-18-2019 06:17 588c309f gh_ha325e2c32g1s050vfio.inp 3,911 11-18-2019 01:25 4dc639c9 gh_ha325e2c32g1s050vfio.out 653,815 11-18-2019 06:46 1bd6f09e gh_ha325e2c32g1s070vfio.inp 3,911 11-18-2019 01:25 c6931a82 gh_ha325e2c32g1s070vfio.out 654,283 11-18-2019 06:54 8f6d3e8c gh_ha325e2c32g1s090vfio.inp 3,911 11-18-2019 01:25 ef907401 gh_ha325e2c32g1s090vfio.out 654,632 11-18-2019 06:47 2082b85c gh_ha325e2c32g1s095vfio.inp 3,911 11-18-2019 01:25 e7164abe gh_ha325e2c32g1s095vfio.out 654,233 11-18-2019 06:44 65141206 gh_ha325e2c32g1s100vfio.inp 3,911 11-18-2019 01:25 b53cead4 gh_ha325e2c32g1s100vfio.out 653,389 11-18-2019 07:05 07768973
\\v1.2\\gh\\na245\\ (18) 4,588,599 11-22-2019 12:48 gh_na245e2c32g1s001vfio.inp 3,735 11-18-2019 12:05 3f027fef
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
156 of 190 gh_na245e2c32g1s001vfio.out 506,425 11-19-2019 10:01 3fe0bc2f gh_na245e2c32g1s005vfio.inp 3,735 11-18-2019 12:05 d7d8954c gh_na245e2c32g1s005vfio.out 506,453 11-19-2019 08:36 7e8c5b02 gh_na245e2c32g1s010vfio.inp 3,735 11-18-2019 12:05 1e5577b0 gh_na245e2c32g1s010vfio.out 506,393 11-19-2019 08:16 4fd049b9 gh_na245e2c32g1s030vfio.inp 3,735 11-18-2019 12:05 08ba4ce2 gh_na245e2c32g1s030vfio.out 506,098 11-19-2019 08:32 014106a9 gh_na245e2c32g1s050vfio.inp 3,735 11-18-2019 12:05 40c5f0c4 gh_na245e2c32g1s050vfio.out 505,270 11-19-2019 08:42 218c5703 gh_na245e2c32g1s070vfio.inp 3,735 11-18-2019 12:05 7e2ac78d gh_na245e2c32g1s070vfio.out 505,513 11-19-2019 08:50 c6bb407c gh_na245e2c32g1s090vfio.inp 3,735 11-18-2019 12:05 3958dc25 gh_na245e2c32g1s090vfio.out 505,901 11-19-2019 08:57 05988644 gh_na245e2c32g1s095vfio.inp 3,735 11-18-2019 12:05 df27750d gh_na245e2c32g1s095vfio.out 506,060 11-19-2019 09:06 b3af2608 gh_na245e2c32g1s100vfio.inp 3,735 11-18-2019 12:05 f65ff418 gh_na245e2c32g1s100vfio.out 506,871 11-19-2019 08:56 2771fa2f
\\v1.2\\gh\\na325\\ (18) 4,609,779 11-22-2019 12:48 gh_na325e2c32g1s001vfio.inp 3,943 11-18-2019 11:00 6c36d7c9 gh_na325e2c32g1s001vfio.out 508,411 11-19-2019 01:44 0dd3926a gh_na325e2c32g1s005vfio.inp 3,943 11-18-2019 11:00 cba86980 gh_na325e2c32g1s005vfio.out 508,552 11-19-2019 00:47 0cd694ee gh_na325e2c32g1s010vfio.inp 3,943 11-18-2019 11:00 bc6a3a8f gh_na325e2c32g1s010vfio.out 508,232 11-19-2019 00:25 95ae64b5 gh_na325e2c32g1s030vfio.inp 3,943 11-18-2019 11:00 66f05d9b gh_na325e2c32g1s030vfio.out 508,304 11-19-2019 00:33 3414ff9a gh_na325e2c32g1s050vfio.inp 3,943 11-18-2019 11:00 dc823ec9 gh_na325e2c32g1s050vfio.out 508,575 11-19-2019 00:46 c34b6b08 gh_na325e2c32g1s070vfio.inp 3,943 11-18-2019 11:00 204b1a88 gh_na325e2c32g1s070vfio.out 507,938 11-19-2019 00:57 34d5ccda gh_na325e2c32g1s090vfio.inp 3,943 11-18-2019 11:00 5095f204 gh_na325e2c32g1s090vfio.out 508,121 11-19-2019 00:59 4f799872 gh_na325e2c32g1s095vfio.inp 3,943 11-18-2019 11:00 48016884 gh_na325e2c32g1s095vfio.out 508,205 11-19-2019 01:01 717fe346 gh_na325e2c32g1s100vfio.inp 3,943 11-18-2019 11:00 f2b11def gh_na325e2c32g1s100vfio.out 507,954 11-19-2019 01:08 798f4eba
\\v1.2\\gi\\ (0) 28,779,319 11-18-2019 15:34
\\v1.2\\gi\\ha245\\ (22) 7,218,788 11-18-2019 20:33 gi_ha245e2c32g1s0500hx.inp 3,767 11-18-2019 09:44 c1c8c834 gi_ha245e2c32g1s0500hx.out 652,005 11-18-2019 17:27 a8cb6ee4 gi_ha245e2c32g1s0600hx.inp 3,768 11-18-2019 09:44 90196537 gi_ha245e2c32g1s0600hx.out 652,009 11-18-2019 17:25 123e4b5c gi_ha245e2c32g1s0700hx.inp 3,768 11-18-2019 09:44 cb315095 gi_ha245e2c32g1s0700hx.out 653,497 11-18-2019 17:29 18a7db1e gi_ha245e2c32g1s0800hx.inp 3,768 11-18-2019 09:45 50518235 gi_ha245e2c32g1s0800hx.out 651,657 11-18-2019 17:28 fd62b5e8 gi_ha245e2c32g1s0900hx.inp 3,768 11-18-2019 09:45 86eb9dd7 gi_ha245e2c32g1s0900hx.out 652,607 11-18-2019 17:29 c142f042 gi_ha245e2c32g1s1000hx.inp 3,772 11-18-2019 09:45 6fcb1fe5 gi_ha245e2c32g1s1000hx.out 653,068 11-18-2019 17:30 9c22c799 gi_ha245e2c32g1s1100hx.inp 3,772 11-18-2019 09:45 aa490d6f gi_ha245e2c32g1s1100hx.out 652,566 11-18-2019 17:31 4914934b gi_ha245e2c32g1s1200hx.inp 3,772 11-18-2019 09:45 14163364 gi_ha245e2c32g1s1200hx.out 652,464 11-18-2019 17:34 725e44a7 gi_ha245e2c32g1s1300hx.inp 3,772 11-18-2019 09:45 50552230 gi_ha245e2c32g1s1300hx.out 652,501 11-18-2019 17:28 ff490e36 gi_ha245e2c32g1s1400hx.inp 3,772 11-18-2019 09:45 85c4c07a gi_ha245e2c32g1s1400hx.out 652,312 11-18-2019 17:42 77e8f3cd gi_ha245e2c32g1s1500hx.inp 3,772 11-18-2019 09:45 ad56ccff gi_ha245e2c32g1s1500hx.out 652,631 11-18-2019 17:50 6db748a6
\\v1.2\\gi\\ha325\\ (22) 7,242,159 11-18-2019 20:33 gi_ha325e2c32g1s0500hx.inp 3,955 11-18-2019 01:36 412b2d8a gi_ha325e2c32g1s0500hx.out 654,018 11-18-2019 07:59 fb112096 gi_ha325e2c32g1s0600hx.inp 3,955 11-18-2019 01:36 2bb726dd gi_ha325e2c32g1s0600hx.out 653,412 11-18-2019 08:29 63469777 gi_ha325e2c32g1s0700hx.inp 3,955 11-18-2019 01:36 a4e16764 gi_ha325e2c32g1s0700hx.out 654,301 11-18-2019 08:30 1df480f3 gi_ha325e2c32g1s0800hx.inp 3,955 11-18-2019 01:36 7f32e070 gi_ha325e2c32g1s0800hx.out 653,328 11-18-2019 07:45 3658e828 gi_ha325e2c32g1s0900hx.inp 3,955 11-18-2019 01:36 6fd65661 gi_ha325e2c32g1s0900hx.out 654,726 11-18-2019 08:29 cb622554 gi_ha325e2c32g1s1000hx.inp 3,959 11-18-2019 01:36 804b379c gi_ha325e2c32g1s1000hx.out 654,585 11-18-2019 08:00 dfa82f7f
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
157 of 190 gi_ha325e2c32g1s1100hx.inp 3,959 11-18-2019 01:36 cff68dd7 gi_ha325e2c32g1s1100hx.out 655,635 11-18-2019 08:46 181e8aa1 gi_ha325e2c32g1s1200hx.inp 3,959 11-18-2019 01:36 0741e403 gi_ha325e2c32g1s1200hx.out 655,047 11-18-2019 08:17 a418578d gi_ha325e2c32g1s1300hx.inp 3,959 11-18-2019 01:37 b485d700 gi_ha325e2c32g1s1300hx.out 654,485 11-18-2019 07:55 4ecc46a9 gi_ha325e2c32g1s1400hx.inp 3,959 11-18-2019 01:37 77086774 gi_ha325e2c32g1s1400hx.out 654,556 11-18-2019 08:50 0e544367 gi_ha325e2c32g1s1500hx.inp 3,958 11-18-2019 01:37 03dc3f24 gi_ha325e2c32g1s1500hx.out 654,538 11-18-2019 08:15 e8a57a42
\\v1.2\\gi\\na245\\ (22) 7,074,074 11-20-2019 09:22 gi_na245e2c32g1s0500hx.inp 3,767 11-18-2019 11:54 45eb4f11 gi_na245e2c32g1s0500hx.out 506,244 11-19-2019 08:47 e802f5a2 gi_na245e2c32g1s0600hx.inp 3,768 11-18-2019 11:54 2a0c590d gi_na245e2c32g1s0600hx.out 652,628 11-19-2019 09:05 a34c0dd7 gi_na245e2c32g1s0700hx.inp 3,768 11-18-2019 11:54 71246caf gi_na245e2c32g1s0700hx.out 652,666 11-19-2019 08:51 b9f18334 gi_na245e2c32g1s0800hx.inp 3,768 11-18-2019 11:54 ea44be0f gi_na245e2c32g1s0800hx.out 653,016 11-19-2019 09:01 507cb7f0 gi_na245e2c32g1s0900hx.inp 3,768 11-18-2019 11:54 3cfea1ed gi_na245e2c32g1s0900hx.out 652,442 11-19-2019 08:59 fc277f85 gi_na245e2c32g1s1000hx.inp 3,772 11-18-2019 11:54 52b10f4a gi_na245e2c32g1s1000hx.out 652,643 11-19-2019 09:01 0a9f2e4d gi_na245e2c32g1s1100hx.inp 3,772 11-18-2019 11:54 97331dc0 gi_na245e2c32g1s1100hx.out 652,106 11-19-2019 09:01 6ae4e178 gi_na245e2c32g1s1200hx.inp 3,772 11-18-2019 11:54 296c23cb gi_na245e2c32g1s1200hx.out 653,177 11-19-2019 09:03 61860ece gi_na245e2c32g1s1300hx.inp 3,772 11-18-2019 11:54 6d2f329f gi_na245e2c32g1s1300hx.out 652,690 11-19-2019 09:14 8f9d5b90 gi_na245e2c32g1s1400hx.inp 3,772 11-18-2019 11:55 b8bed0d5 gi_na245e2c32g1s1400hx.out 652,238 11-19-2019 09:17 3d9fe937 gi_na245e2c32g1s1500hx.inp 3,772 11-18-2019 11:55 902cdc50 gi_na245e2c32g1s1500hx.out 652,753 11-19-2019 09:16 5f5990f8
\\v1.2\\gi\\na325\\ (22) 7,244,298 11-20-2019 09:22 gi_na325e2c32g1s0500hx.inp 3,987 11-18-2019 10:49 4b5bab28 gi_na325e2c32g1s0500hx.out 654,519 11-19-2019 01:06 04e4939c gi_na325e2c32g1s0600hx.inp 3,987 11-18-2019 10:49 aeab0c12 gi_na325e2c32g1s0600hx.out 654,152 11-19-2019 00:59 d29c2953 gi_na325e2c32g1s0700hx.inp 3,987 11-18-2019 10:50 51d290f7 gi_na325e2c32g1s0700hx.out 654,239 11-19-2019 01:01 e7b58da2 gi_na325e2c32g1s0800hx.inp 3,987 11-18-2019 10:50 2abf375d gi_na325e2c32g1s0800hx.out 655,416 11-19-2019 01:02 368c4ec1 gi_na325e2c32g1s0900hx.inp 3,987 11-18-2019 10:50 dd2a5070 gi_na325e2c32g1s0900hx.out 654,387 11-19-2019 01:03 a508a3b3 gi_na325e2c32g1s1000hx.inp 3,991 11-18-2019 10:50 2bd544f5 gi_na325e2c32g1s1000hx.out 655,167 11-19-2019 01:08 3c582bd4 gi_na325e2c32g1s1100hx.inp 3,991 11-18-2019 10:50 b689bda3 gi_na325e2c32g1s1100hx.out 654,330 11-19-2019 01:03 c87c8d30 gi_na325e2c32g1s1200hx.inp 3,991 11-18-2019 10:50 835a825c gi_na325e2c32g1s1200hx.out 654,288 11-19-2019 01:05 725b971c gi_na325e2c32g1s1300hx.inp 3,991 11-18-2019 10:50 50b96796 gi_na325e2c32g1s1300hx.out 655,110 11-19-2019 01:07 bcdc0626 gi_na325e2c32g1s1400hx.inp 3,991 11-18-2019 10:50 56a4123b gi_na325e2c32g1s1400hx.out 654,372 11-19-2019 01:06 c5d308b0 gi_na325e2c32g1s1500hx.inp 3,990 11-18-2019 10:50 98421739 gi_na325e2c32g1s1500hx.out 654,438 11-19-2019 01:17 3745a684
\\v1.2\\gj\\ (0) 26,289,573 11-18-2019 15:34
\\v1.2\\gj\\ha245\\ (22) 7,219,098 11-18-2019 20:33 gj_ha245e2c32g1s0500hx.inp 3,772 11-18-2019 09:45 48cb9ab7 gj_ha245e2c32g1s0500hx.out 652,755 11-18-2019 17:45 c9d4a3bf gj_ha245e2c32g1s0600hx.inp 3,773 11-18-2019 09:45 3ac9c24c gj_ha245e2c32g1s0600hx.out 651,440 11-18-2019 17:39 8ea26ee4 gj_ha245e2c32g1s0700hx.inp 3,773 11-18-2019 09:45 3f1c7ca0 gj_ha245e2c32g1s0700hx.out 652,484 11-18-2019 17:45 f0849120 gj_ha245e2c32g1s0800hx.inp 3,773 11-18-2019 09:45 125a2e8c gj_ha245e2c32g1s0800hx.out 653,343 11-18-2019 17:45 f57572b9 gj_ha245e2c32g1s0900hx.inp 3,771 11-18-2019 09:46 f4b050a2 gj_ha245e2c32g1s0900hx.out 652,274 11-18-2019 17:48 ba1e3821 gj_ha245e2c32g1s1000hx.inp 3,775 11-18-2019 09:46 1acd305e gj_ha245e2c32g1s1000hx.out 653,126 11-18-2019 17:46 007b4ad2 gj_ha245e2c32g1s1100hx.inp 3,775 11-18-2019 09:46 b8a2a866 gj_ha245e2c32g1s1100hx.out 652,462 11-18-2019 17:47 9a63720d gj_ha245e2c32g1s1200hx.inp 3,775 11-18-2019 09:46 f809565e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
158 of 190 gj_ha245e2c32g1s1200hx.out 652,456 11-18-2019 17:48 b991b7e4 gj_ha245e2c32g1s1300hx.inp 3,775 11-18-2019 09:46 cce0cf15 gj_ha245e2c32g1s1300hx.out 652,742 11-18-2019 17:49 12140ada gj_ha245e2c32g1s1400hx.inp 3,775 11-18-2019 09:46 224c670f gj_ha245e2c32g1s1400hx.out 652,138 11-18-2019 17:52 7c73bcc9 gj_ha245e2c32g1s1500hx.inp 3,775 11-18-2019 09:46 2ae86280 gj_ha245e2c32g1s1500hx.out 652,366 11-18-2019 17:56 049a91cb
\\v1.2\\gj\\ha325\\ (22) 7,242,098 11-18-2019 20:33 gj_ha325e2c32g1s0500hx.inp 3,960 11-18-2019 01:37 8c5b3200 gj_ha325e2c32g1s0500hx.out 654,626 11-18-2019 08:46 38c0bfe9 gj_ha325e2c32g1s0600hx.inp 3,958 11-18-2019 01:37 81aa9ca6 gj_ha325e2c32g1s0600hx.out 653,397 11-18-2019 08:24 988c70a4 gj_ha325e2c32g1s0700hx.inp 3,958 11-18-2019 01:37 d5271b8e gj_ha325e2c32g1s0700hx.out 654,109 11-18-2019 08:41 8a1d47b2 gj_ha325e2c32g1s0800hx.inp 3,958 11-18-2019 01:37 e355f899 gj_ha325e2c32g1s0800hx.out 654,890 11-18-2019 08:28 0986ce21 gj_ha325e2c32g1s0900hx.inp 3,958 11-18-2019 01:37 62a6304a gj_ha325e2c32g1s0900hx.out 654,703 11-18-2019 08:01 2345042d gj_ha325e2c32g1s1000hx.inp 3,962 11-18-2019 01:37 2e7a4dea gj_ha325e2c32g1s1000hx.out 654,099 11-18-2019 08:07 2a6abe97 gj_ha325e2c32g1s1100hx.inp 3,962 11-18-2019 01:37 919d34f1 gj_ha325e2c32g1s1100hx.out 654,651 11-18-2019 08:51 9b79f78a gj_ha325e2c32g1s1200hx.inp 3,962 11-18-2019 01:37 18caf675 gj_ha325e2c32g1s1200hx.out 654,196 11-18-2019 08:57 233e73e8 gj_ha325e2c32g1s1300hx.inp 3,962 11-18-2019 01:37 3261ad07 gj_ha325e2c32g1s1300hx.out 654,160 11-18-2019 08:04 ee28c7a5 gj_ha325e2c32g1s1400hx.inp 3,962 11-18-2019 01:38 364e2bf1 gj_ha325e2c32g1s1400hx.out 654,515 11-18-2019 08:48 823fa085 gj_ha325e2c32g1s1500hx.inp 3,962 11-18-2019 01:38 563a8fa4 gj_ha325e2c32g1s1500hx.out 655,188 11-18-2019 08:20 9a3372a4
\\v1.2\\gj\\na245\\ (22) 5,608,714 11-20-2019 09:22 gj_na245e2c32g1s0500hx.inp 3,772 11-18-2019 11:55 b8fc1b10 gj_na245e2c32g1s0500hx.out 506,679 11-19-2019 09:19 e8e1034c gj_na245e2c32g1s0600hx.inp 3,773 11-18-2019 11:55 831e087c gj_na245e2c32g1s0600hx.out 506,369 11-19-2019 09:15 c4254b4a gj_na245e2c32g1s0700hx.inp 3,773 11-18-2019 11:55 86cbb690 gj_na245e2c32g1s0700hx.out 506,595 11-19-2019 09:10 d8514165 gj_na245e2c32g1s0800hx.inp 3,773 11-18-2019 11:55 ab8de4bc gj_na245e2c32g1s0800hx.out 506,189 11-19-2019 09:04 2c0c7e97 gj_na245e2c32g1s0900hx.inp 3,771 11-18-2019 11:55 8d8b0be3 gj_na245e2c32g1s0900hx.out 505,238 11-19-2019 09:05 84339585 gj_na245e2c32g1s1000hx.inp 3,775 11-18-2019 11:55 7c1206e4 gj_na245e2c32g1s1000hx.out 505,833 11-19-2019 09:11 bce7c2e2 gj_na245e2c32g1s1100hx.inp 3,775 11-18-2019 11:55 de7d9edc gj_na245e2c32g1s1100hx.out 506,045 11-19-2019 09:07 41bc6e6d gj_na245e2c32g1s1200hx.inp 3,775 11-18-2019 11:55 9ed660e4 gj_na245e2c32g1s1200hx.out 505,434 11-19-2019 09:25 90a2a460 gj_na245e2c32g1s1300hx.inp 3,775 11-18-2019 11:56 aa3ff9af gj_na245e2c32g1s1300hx.out 506,143 11-19-2019 09:23 e53a4235 gj_na245e2c32g1s1400hx.inp 3,775 11-18-2019 11:56 449351b5 gj_na245e2c32g1s1400hx.out 506,225 11-19-2019 09:17 5d2fc087 gj_na245e2c32g1s1500hx.inp 3,775 11-18-2019 11:56 4c37543a gj_na245e2c32g1s1500hx.out 506,452 11-19-2019 09:19 9ca5ddcf
\\v1.2\\gj\\na325\\ (22) 6,219,663 11-20-2019 09:22 gj_na325e2c32g1s0500hx.inp 3,992 11-18-2019 10:50 3f0164cb gj_na325e2c32g1s0500hx.out 508,307 11-19-2019 01:10 9c11f449 gj_na325e2c32g1s0600hx.inp 3,990 11-18-2019 10:50 c4f93a92 gj_na325e2c32g1s0600hx.out 507,272 11-19-2019 01:05 3431d814 gj_na325e2c32g1s0700hx.inp 3,990 11-18-2019 10:51 6a95ec15 gj_na325e2c32g1s0700hx.out 508,439 11-19-2019 01:16 300c24de gj_na325e2c32g1s0800hx.inp 3,990 11-18-2019 10:51 2a7a6691 gj_na325e2c32g1s0800hx.out 508,393 11-19-2019 01:17 a3f4acaf gj_na325e2c32g1s0900hx.inp 3,990 11-18-2019 10:51 39d907a5 gj_na325e2c32g1s0900hx.out 508,534 11-19-2019 01:10 189b04f0 gj_na325e2c32g1s1000hx.inp 3,994 11-18-2019 10:51 7cb15483 gj_na325e2c32g1s1000hx.out 509,376 11-19-2019 01:10 c3b75543 gj_na325e2c32g1s1100hx.inp 3,994 11-18-2019 10:51 dbf1d341 gj_na325e2c32g1s1100hx.out 507,203 11-19-2019 01:25 a16fc371 gj_na325e2c32g1s1200hx.inp 3,994 11-18-2019 10:51 c080e7aa gj_na325e2c32g1s1200hx.out 654,658 11-19-2019 01:24 2fb5b2f6 gj_na325e2c32g1s1300hx.inp 3,994 11-18-2019 10:51 063dc685 gj_na325e2c32g1s1300hx.out 654,645 11-19-2019 01:36 5100f0dd gj_na325e2c32g1s1400hx.inp 3,994 11-18-2019 10:51 c6c8fe46 gj_na325e2c32g1s1400hx.out 654,389 11-19-2019 01:42 ecab5665 gj_na325e2c32g1s1500hx.inp 3,994 11-18-2019 10:51 5c581844
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
159 of 190 gj_na325e2c32g1s1500hx.out 654,531 11-19-2019 01:45 cc358759
\\v1.2\\gk\\ (0) 23,668,284 11-18-2019 15:34
\\v1.2\\gk\\ha245\\ (18) 5,906,464 11-22-2019 12:48 gk_ha245e2c32g1s001vfio.inp 3,768 11-18-2019 09:46 8776d4d6 gk_ha245e2c32g1s001vfio.out 652,498 11-18-2019 17:06 72647ff4 gk_ha245e2c32g1s005vfio.inp 3,768 11-18-2019 09:46 e4f5c762 gk_ha245e2c32g1s005vfio.out 652,365 11-18-2019 16:38 bb3b0b1e gk_ha245e2c32g1s010vfio.inp 3,768 11-18-2019 09:46 38002191 gk_ha245e2c32g1s010vfio.out 653,206 11-18-2019 16:50 1060eae0 gk_ha245e2c32g1s030vfio.inp 3,768 11-18-2019 09:46 14a3689e gk_ha245e2c32g1s030vfio.out 651,327 11-18-2019 17:25 c68f1fd1 gk_ha245e2c32g1s050vfio.inp 3,768 11-18-2019 09:47 781a0ce0 gk_ha245e2c32g1s050vfio.out 652,537 11-18-2019 17:29 206c21a8 gk_ha245e2c32g1s070vfio.inp 3,768 11-18-2019 09:47 5057d6e0 gk_ha245e2c32g1s070vfio.out 653,066 11-18-2019 17:45 3b08a7af gk_ha245e2c32g1s090vfio.inp 3,768 11-18-2019 09:47 123cde05 gk_ha245e2c32g1s090vfio.out 652,575 11-18-2019 17:44 1b6e7088 gk_ha245e2c32g1s095vfio.inp 3,768 11-18-2019 09:47 c4212bd8 gk_ha245e2c32g1s095vfio.out 652,370 11-18-2019 17:52 6a0d08ac gk_ha245e2c32g1s100vfio.inp 3,768 11-18-2019 09:47 86eb9dd7 gk_ha245e2c32g1s100vfio.out 652,608 11-18-2019 18:03 aeb8726d
\\v1.2\\gk\\ha325\\ (18) 5,927,874 11-22-2019 12:48 gk_ha325e2c32g1s001vfio.inp 3,955 11-18-2019 01:38 e0401df3 gk_ha325e2c32g1s001vfio.out 656,077 11-18-2019 08:23 a4ee43e2 gk_ha325e2c32g1s005vfio.inp 3,955 11-18-2019 01:38 f1006de5 gk_ha325e2c32g1s005vfio.out 654,855 11-18-2019 07:32 e7c0c6c5 gk_ha325e2c32g1s010vfio.inp 3,955 11-18-2019 01:38 75518312 gk_ha325e2c32g1s010vfio.out 654,223 11-18-2019 07:57 24f77166 gk_ha325e2c32g1s030vfio.inp 3,955 11-18-2019 01:38 dc655cbb gk_ha325e2c32g1s030vfio.out 654,278 11-18-2019 08:32 386857ca gk_ha325e2c32g1s050vfio.inp 3,955 11-18-2019 01:38 d8f54535 gk_ha325e2c32g1s050vfio.out 654,754 11-18-2019 08:37 033dfcf0 gk_ha325e2c32g1s070vfio.inp 3,955 11-18-2019 01:38 6f1560ee gk_ha325e2c32g1s070vfio.out 653,610 11-18-2019 09:00 b85c65b5 gk_ha325e2c32g1s090vfio.inp 3,955 11-18-2019 01:38 9f7da133 gk_ha325e2c32g1s090vfio.out 654,801 11-18-2019 08:45 d6527b40 gk_ha325e2c32g1s095vfio.inp 3,955 11-18-2019 01:38 5d86003f gk_ha325e2c32g1s095vfio.out 654,953 11-18-2019 08:53 0f7fdfee gk_ha325e2c32g1s100vfio.inp 3,955 11-18-2019 01:39 6fd65661 gk_ha325e2c32g1s100vfio.out 654,728 11-18-2019 09:15 96b991ec
\\v1.2\\gk\\na245\\ (18) 5,908,195 11-22-2019 12:48 gk_na245e2c32g1s001vfio.inp 3,768 11-18-2019 11:56 3d63e8ec gk_na245e2c32g1s001vfio.out 652,608 11-19-2019 08:35 16e24995 gk_na245e2c32g1s005vfio.inp 3,768 11-18-2019 11:56 5ee0fb58 gk_na245e2c32g1s005vfio.out 652,934 11-19-2019 08:08 edcc9ac3 gk_na245e2c32g1s010vfio.inp 3,768 11-18-2019 11:56 82151dab gk_na245e2c32g1s010vfio.out 652,544 11-19-2019 08:21 939fc6cc gk_na245e2c32g1s030vfio.inp 3,768 11-18-2019 11:56 aeb654a4 gk_na245e2c32g1s030vfio.out 652,698 11-19-2019 08:47 d8377b9e gk_na245e2c32g1s050vfio.inp 3,768 11-18-2019 11:56 c20f30da gk_na245e2c32g1s050vfio.out 652,783 11-19-2019 09:08 70aaa9e6 gk_na245e2c32g1s070vfio.inp 3,768 11-18-2019 11:56 ea42eada gk_na245e2c32g1s070vfio.out 652,707 11-19-2019 09:19 ee63ffbd gk_na245e2c32g1s090vfio.inp 3,768 11-18-2019 11:56 a829e23f gk_na245e2c32g1s090vfio.out 653,077 11-19-2019 09:32 74e7f6a5 gk_na245e2c32g1s095vfio.inp 3,768 11-18-2019 11:56 7e3417e2 gk_na245e2c32g1s095vfio.out 652,491 11-19-2019 09:30 be49f045 gk_na245e2c32g1s100vfio.inp 3,768 11-18-2019 11:57 3cfea1ed gk_na245e2c32g1s100vfio.out 652,441 11-19-2019 09:30 c2bf8afb
\\v1.2\\gk\\na325\\ (18) 5,925,751 11-22-2019 12:48 gk_na325e2c32g1s001vfio.inp 3,987 11-18-2019 10:51 88cc289e gk_na325e2c32g1s001vfio.out 654,002 11-19-2019 01:09 3fbd44d3 gk_na325e2c32g1s005vfio.inp 3,987 11-18-2019 10:51 ddb36e2a gk_na325e2c32g1s005vfio.out 653,535 11-19-2019 00:26 31f82558 gk_na325e2c32g1s010vfio.inp 3,987 11-18-2019 10:52 847984f4 gk_na325e2c32g1s010vfio.out 655,270 11-19-2019 00:31 6f55cde8 gk_na325e2c32g1s030vfio.inp 3,987 11-18-2019 10:52 e3fa4fe9 gk_na325e2c32g1s030vfio.out 654,418 11-19-2019 01:09 18aa7fbc gk_na325e2c32g1s050vfio.inp 3,987 11-18-2019 10:52 648e935e gk_na325e2c32g1s050vfio.out 654,259 11-19-2019 01:15 01188ba5 gk_na325e2c32g1s070vfio.inp 3,987 11-18-2019 10:52 4d01f31a
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
160 of 190 gk_na325e2c32g1s070vfio.out 654,573 11-19-2019 01:37 66bdc2dc gk_na325e2c32g1s090vfio.inp 3,987 11-18-2019 10:52 c0e529ce gk_na325e2c32g1s090vfio.out 654,834 11-19-2019 01:56 ecd98534 gk_na325e2c32g1s095vfio.inp 3,987 11-18-2019 10:52 531cc6fc gk_na325e2c32g1s095vfio.out 654,587 11-19-2019 01:36 8e0fe0bc gk_na325e2c32g1s100vfio.inp 3,987 11-18-2019 10:52 dd2a5070 gk_na325e2c32g1s100vfio.out 654,390 11-19-2019 01:46 0a0b4891
\\v1.2\\gl\\ (0) 21,030,853 11-18-2019 15:34
\\v1.2\\gl\\ha245\\ (18) 5,907,258 11-22-2019 12:48 gl_ha245e2c32g1s001vfio.inp 3,771 11-18-2019 09:47 ae1aad80 gl_ha245e2c32g1s001vfio.out 652,696 11-18-2019 17:14 883a6628 gl_ha245e2c32g1s005vfio.inp 3,771 11-18-2019 09:47 841fd4a3 gl_ha245e2c32g1s005vfio.out 652,007 11-18-2019 16:49 01e3771f gl_ha245e2c32g1s010vfio.inp 3,771 11-18-2019 09:47 3bba7dcc gl_ha245e2c32g1s010vfio.out 653,087 11-18-2019 17:04 f9f6a7c5 gl_ha245e2c32g1s030vfio.inp 3,771 11-18-2019 09:47 7b68ba36 gl_ha245e2c32g1s030vfio.out 652,572 11-18-2019 17:35 b0092666 gl_ha245e2c32g1s050vfio.inp 3,771 11-18-2019 09:47 9a7293a6 gl_ha245e2c32g1s050vfio.out 652,522 11-18-2019 18:03 34553ea5 gl_ha245e2c32g1s070vfio.inp 3,771 11-18-2019 09:47 85a9a712 gl_ha245e2c32g1s070vfio.out 652,637 11-18-2019 18:11 fb443faf gl_ha245e2c32g1s090vfio.inp 3,771 11-18-2019 09:48 6edc6306 gl_ha245e2c32g1s090vfio.out 652,729 11-18-2019 18:02 e5fda2a1 gl_ha245e2c32g1s095vfio.inp 3,771 11-18-2019 09:48 71a46eba gl_ha245e2c32g1s095vfio.out 652,796 11-18-2019 18:02 0828c330 gl_ha245e2c32g1s100vfio.inp 3,771 11-18-2019 09:48 f4b050a2 gl_ha245e2c32g1s100vfio.out 652,273 11-18-2019 18:02 82954454
\\v1.2\\gl\\ha325\\ (18) 5,926,354 11-22-2019 12:48 gl_ha325e2c32g1s001vfio.inp 3,958 11-18-2019 01:39 4da4d6b6 gl_ha325e2c32g1s001vfio.out 655,116 11-18-2019 08:36 99d1a6e5 gl_ha325e2c32g1s005vfio.inp 3,958 11-18-2019 01:39 a9b5e8d0 gl_ha325e2c32g1s005vfio.out 654,885 11-18-2019 07:57 28fb0874 gl_ha325e2c32g1s010vfio.inp 3,958 11-18-2019 01:39 cbb19e3e gl_ha325e2c32g1s010vfio.out 653,831 11-18-2019 07:57 a3a12d9f gl_ha325e2c32g1s030vfio.inp 3,958 11-18-2019 01:39 1e91a06b gl_ha325e2c32g1s030vfio.out 654,811 11-18-2019 08:03 a3287bf4 gl_ha325e2c32g1s050vfio.inp 3,958 11-18-2019 01:39 2beee1b2 gl_ha325e2c32g1s050vfio.out 654,425 11-18-2019 08:43 3524f7f2 gl_ha325e2c32g1s070vfio.inp 3,958 11-18-2019 01:39 8dfabfff gl_ha325e2c32g1s070vfio.out 654,173 11-18-2019 08:21 61908c9b gl_ha325e2c32g1s090vfio.inp 3,958 11-18-2019 01:39 198f4ae1 gl_ha325e2c32g1s090vfio.out 654,450 11-18-2019 08:18 4678ce29 gl_ha325e2c32g1s095vfio.inp 3,958 11-18-2019 01:39 a0899072 gl_ha325e2c32g1s095vfio.out 654,333 11-18-2019 08:11 45618dc5 gl_ha325e2c32g1s100vfio.inp 3,958 11-18-2019 01:39 62a6304a gl_ha325e2c32g1s100vfio.out 654,708 11-18-2019 09:21 bceb0d88
\\v1.2\\gl\\na245\\ (18) 4,588,538 11-22-2019 12:48 gl_na245e2c32g1s001vfio.inp 3,771 11-18-2019 11:57 d721f6c1 gl_na245e2c32g1s001vfio.out 506,856 11-19-2019 09:00 553c8d74 gl_na245e2c32g1s005vfio.inp 3,771 11-18-2019 11:57 fd248fe2 gl_na245e2c32g1s005vfio.out 505,973 11-19-2019 08:38 4b378855 gl_na245e2c32g1s010vfio.inp 3,771 11-18-2019 11:57 4281268d gl_na245e2c32g1s010vfio.out 506,132 11-19-2019 08:38 bf56d705 gl_na245e2c32g1s030vfio.inp 3,771 11-18-2019 11:57 0253e177 gl_na245e2c32g1s030vfio.out 505,698 11-19-2019 09:17 ca4097a3 gl_na245e2c32g1s050vfio.inp 3,771 11-18-2019 11:57 e349c8e7 gl_na245e2c32g1s050vfio.out 505,798 11-19-2019 09:30 49f3acd0 gl_na245e2c32g1s070vfio.inp 3,771 11-18-2019 11:57 fc92fc53 gl_na245e2c32g1s070vfio.out 506,068 11-19-2019 09:48 f21be66f gl_na245e2c32g1s090vfio.inp 3,771 11-18-2019 11:57 17e73847 gl_na245e2c32g1s090vfio.out 506,801 11-19-2019 09:42 bc32e175 gl_na245e2c32g1s095vfio.inp 3,771 11-18-2019 11:57 089f35fb gl_na245e2c32g1s095vfio.out 506,033 11-19-2019 09:33 4a7d7c00 gl_na245e2c32g1s100vfio.inp 3,771 11-18-2019 11:58 8d8b0be3 gl_na245e2c32g1s100vfio.out 505,240 11-19-2019 09:46 1e637cc6
\\v1.2\\gl\\na325\\ (18) 4,608,703 11-22-2019 12:48 gl_na325e2c32g1s001vfio.inp 3,990 11-18-2019 10:52 ef5e64bb gl_na325e2c32g1s001vfio.out 507,398 11-19-2019 01:17 6b5fcd55 gl_na325e2c32g1s005vfio.inp 3,990 11-18-2019 10:52 eec96fdf gl_na325e2c32g1s005vfio.out 508,368 11-19-2019 00:34 c7c49151 gl_na325e2c32g1s010vfio.inp 3,990 11-18-2019 10:52 b8e0eb4b
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
161 of 190 gl_na325e2c32g1s010vfio.out 508,097 11-19-2019 00:49 2a5dd1fb gl_na325e2c32g1s030vfio.inp 3,990 11-18-2019 10:53 d43c7266 gl_na325e2c32g1s030vfio.out 508,841 11-19-2019 01:16 6a254f18 gl_na325e2c32g1s050vfio.inp 3,990 11-18-2019 10:53 db13e849 gl_na325e2c32g1s050vfio.out 508,249 11-19-2019 01:29 6489c4b1 gl_na325e2c32g1s070vfio.inp 3,990 11-18-2019 10:53 db4b8ede gl_na325e2c32g1s070vfio.out 507,838 11-19-2019 01:35 d02c6d79 gl_na325e2c32g1s090vfio.inp 3,990 11-18-2019 10:53 0dd744a3 gl_na325e2c32g1s090vfio.out 507,688 11-19-2019 01:50 fd7bb551 gl_na325e2c32g1s095vfio.inp 3,990 11-18-2019 10:53 1ad0555c gl_na325e2c32g1s095vfio.out 507,775 11-19-2019 01:51 d9714a7f gl_na325e2c32g1s100vfio.inp 3,990 11-18-2019 10:53 39d907a5 gl_na325e2c32g1s100vfio.out 508,539 11-19-2019 01:53 b284cff2
\\v1.2\\ha\\ (0) 57,424,187 11-18-2019 17:28
\\v1.2\\ha\\ha245\\ (22) 7,200,562 11-18-2019 20:33 ha_ha245e2c51g1s0500hx.inp 3,883 11-18-2019 02:31 722c3aa4 ha_ha245e2c51g1s0500hx.out 650,248 11-18-2019 18:11 8fd9f75e ha_ha245e2c51g1s0600hx.inp 3,884 11-18-2019 02:31 a92d5055 ha_ha245e2c51g1s0600hx.out 651,185 11-18-2019 18:10 fc167135 ha_ha245e2c51g1s0700hx.inp 3,884 11-18-2019 02:31 0ae66ad3 ha_ha245e2c51g1s0700hx.out 651,545 11-18-2019 18:08 17de8543 ha_ha245e2c51g1s0800hx.inp 3,884 11-18-2019 02:31 0744c406 ha_ha245e2c51g1s0800hx.out 649,793 11-18-2019 18:11 720cee33 ha_ha245e2c51g1s0900hx.inp 3,884 11-18-2019 02:31 840d9f3b ha_ha245e2c51g1s0900hx.out 650,003 11-18-2019 18:11 11792912 ha_ha245e2c51g1s1000hx.inp 3,888 11-18-2019 02:31 56023094 ha_ha245e2c51g1s1000hx.out 650,977 11-18-2019 18:14 a4dc0a1f ha_ha245e2c51g1s1100hx.inp 3,888 11-18-2019 02:31 05bcd337 ha_ha245e2c51g1s1100hx.out 650,147 11-18-2019 18:08 266c6e6f ha_ha245e2c51g1s1200hx.inp 3,888 11-18-2019 02:31 7e120b2c ha_ha245e2c51g1s1200hx.out 652,033 11-18-2019 18:12 d7fcb7a7 ha_ha245e2c51g1s1300hx.inp 3,888 11-18-2019 02:31 0755c7a6 ha_ha245e2c51g1s1300hx.out 650,385 11-18-2019 18:17 e852aafe ha_ha245e2c51g1s1400hx.inp 3,888 11-18-2019 02:32 0af4cfe6 ha_ha245e2c51g1s1400hx.out 650,655 11-18-2019 18:19 eddd69ab ha_ha245e2c51g1s1500hx.inp 3,888 11-18-2019 02:32 086c12c7 ha_ha245e2c51g1s1500hx.out 650,844 11-18-2019 18:19 0366231d
\\v1.2\\ha\\ha325\\ (22) 7,191,118 11-18-2019 20:33 ha_ha325e2c51g1s0500hx.inp 3,829 11-18-2019 01:15 64a8ed82 ha_ha325e2c51g1s0500hx.out 649,785 11-18-2019 06:26 ad8058a1 ha_ha325e2c51g1s0600hx.inp 3,829 11-18-2019 01:15 7045ab8a ha_ha325e2c51g1s0600hx.out 649,528 11-18-2019 06:29 530c31da ha_ha325e2c51g1s0700hx.inp 3,829 11-18-2019 01:15 6ff79187 ha_ha325e2c51g1s0700hx.out 651,350 11-18-2019 06:25 34732b2f ha_ha325e2c51g1s0800hx.inp 3,829 11-18-2019 01:15 1f0ca4b6 ha_ha325e2c51g1s0800hx.out 650,046 11-18-2019 06:39 cf445f51 ha_ha325e2c51g1s0900hx.inp 3,829 11-18-2019 01:16 d6ad88ee ha_ha325e2c51g1s0900hx.out 650,105 11-18-2019 06:24 aa0a0b8c ha_ha325e2c51g1s1000hx.inp 3,833 11-18-2019 01:16 829498af ha_ha325e2c51g1s1000hx.out 648,843 11-18-2019 06:28 5aae7209 ha_ha325e2c51g1s1100hx.inp 3,833 11-18-2019 01:16 c1fc3747 ha_ha325e2c51g1s1100hx.out 649,584 11-18-2019 06:27 3035e225 ha_ha325e2c51g1s1200hx.inp 3,833 11-18-2019 01:16 bce68bb6 ha_ha325e2c51g1s1200hx.out 649,885 11-18-2019 06:37 7da54e3c ha_ha325e2c51g1s1300hx.inp 3,833 11-18-2019 01:16 fa3af2cb ha_ha325e2c51g1s1300hx.out 650,064 11-18-2019 06:31 0dc1c924 ha_ha325e2c51g1s1400hx.inp 3,833 11-18-2019 01:16 046718ec ha_ha325e2c51g1s1400hx.out 650,404 11-18-2019 06:33 6f0f7403 ha_ha325e2c51g1s1500hx.inp 3,833 11-18-2019 01:16 a533e7c8 ha_ha325e2c51g1s1500hx.out 649,381 11-18-2019 06:34 463c65b6
\\v1.2\\ha\\hs245\\ (22) 7,203,529 11-20-2019 09:22 ha_hs245e2c51g1s0500hx.inp 3,911 11-18-2019 14:56 d62c511b ha_hs245e2c51g1s0500hx.out 650,507 11-19-2019 20:58 15c89d34 ha_hs245e2c51g1s0600hx.inp 3,912 11-18-2019 14:56 59e4f7c2 ha_hs245e2c51g1s0600hx.out 650,952 11-19-2019 20:57 a19b5aac ha_hs245e2c51g1s0700hx.inp 3,912 11-18-2019 14:56 8ca1ccb0 ha_hs245e2c51g1s0700hx.out 651,009 11-19-2019 20:59 8c472dc2 ha_hs245e2c51g1s0800hx.inp 3,912 11-18-2019 14:56 f1ffd48d ha_hs245e2c51g1s0800hx.out 650,776 11-19-2019 20:59 fc7b75c6 ha_hs245e2c51g1s0900hx.inp 3,912 11-18-2019 14:56 dc83fe7f ha_hs245e2c51g1s0900hx.out 651,160 11-19-2019 21:02 2dd5bccd ha_hs245e2c51g1s1000hx.inp 3,916 11-18-2019 14:57 c024b9b2 ha_hs245e2c51g1s1000hx.out 651,022 11-19-2019 20:49 a95662c9
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
162 of 190 ha_hs245e2c51g1s1100hx.inp 3,916 11-18-2019 14:57 02a3fae1 ha_hs245e2c51g1s1100hx.out 650,744 11-19-2019 20:57 8b71f96f ha_hs245e2c51g1s1200hx.inp 3,916 11-18-2019 14:57 19d99d91 ha_hs245e2c51g1s1200hx.out 651,071 11-19-2019 21:07 12c7b1f8 ha_hs245e2c51g1s1300hx.inp 3,916 11-18-2019 14:57 97e250d9 ha_hs245e2c51g1s1300hx.out 650,888 11-19-2019 21:03 83947ecc ha_hs245e2c51g1s1400hx.inp 3,916 11-18-2019 14:57 e18a0579 ha_hs245e2c51g1s1400hx.out 650,283 11-19-2019 21:07 6ba48736 ha_hs245e2c51g1s1500hx.inp 3,916 11-18-2019 14:57 967ff9d0 ha_hs245e2c51g1s1500hx.out 652,062 11-19-2019 21:00 266a4fe9
\\v1.2\\ha\\hs325\\ (22) 7,190,535 11-20-2019 09:22 ha_hs325e2c51g1s0500hx.inp 3,862 11-18-2019 13:08 ce4401b1 ha_hs325e2c51g1s0500hx.out 650,692 11-19-2019 15:36 1c101166 ha_hs325e2c51g1s0600hx.inp 3,862 11-18-2019 13:08 8fb7ee11 ha_hs325e2c51g1s0600hx.out 650,004 11-19-2019 15:47 75d49587 ha_hs325e2c51g1s0700hx.inp 3,862 11-18-2019 13:08 8db01ef0 ha_hs325e2c51g1s0700hx.out 650,566 11-19-2019 15:32 e0598d67 ha_hs325e2c51g1s0800hx.inp 3,862 11-18-2019 13:08 06b85b2a ha_hs325e2c51g1s0800hx.out 649,459 11-19-2019 15:47 5e5c69ab ha_hs325e2c51g1s0900hx.inp 3,862 11-18-2019 13:08 a1615256 ha_hs325e2c51g1s0900hx.out 649,510 11-19-2019 15:31 3c0026ab ha_hs325e2c51g1s1000hx.inp 3,866 11-18-2019 13:08 d265fc27 ha_hs325e2c51g1s1000hx.out 649,092 11-19-2019 15:33 d0722ed1 ha_hs325e2c51g1s1100hx.inp 3,866 11-18-2019 13:09 73dc5be3 ha_hs325e2c51g1s1100hx.out 649,856 11-19-2019 15:50 f7be1570 ha_hs325e2c51g1s1200hx.inp 3,866 11-18-2019 13:09 8a29c6b5 ha_hs325e2c51g1s1200hx.out 650,173 11-19-2019 15:50 db6020a8 ha_hs325e2c51g1s1300hx.inp 3,866 11-18-2019 13:09 a856006b ha_hs325e2c51g1s1300hx.out 649,786 11-19-2019 15:51 9e22fba9 ha_hs325e2c51g1s1400hx.inp 3,866 11-18-2019 13:09 3a8fb7a3 ha_hs325e2c51g1s1400hx.out 649,856 11-19-2019 15:57 adfd6ca7 ha_hs325e2c51g1s1500hx.inp 3,866 11-18-2019 13:09 3613140c ha_hs325e2c51g1s1500hx.out 649,035 11-19-2019 16:05 08bc685b
\\v1.2\\ha\\na245\\ (22) 7,054,860 11-20-2019 09:22 ha_na245e2c51g1s0500hx.inp 3,910 11-18-2019 11:46 3643646e ha_na245e2c51g1s0500hx.out 504,455 11-19-2019 09:53 6f410c72 ha_na245e2c51g1s0600hx.inp 3,911 11-18-2019 11:46 43335b40 ha_na245e2c51g1s0600hx.out 649,967 11-19-2019 09:50 0c0c8206 ha_na245e2c51g1s0700hx.inp 3,911 11-18-2019 11:46 742ebc3c ha_na245e2c51g1s0700hx.out 650,771 11-19-2019 09:52 2fb3f5ce ha_na245e2c51g1s0800hx.inp 3,911 11-18-2019 11:46 7b88dd2d ha_na245e2c51g1s0800hx.out 650,608 11-19-2019 09:50 ef0490ea ha_na245e2c51g1s0900hx.inp 3,911 11-18-2019 11:46 a1504a74 ha_na245e2c51g1s0900hx.out 651,472 11-19-2019 09:52 7a06b7a4 ha_na245e2c51g1s1000hx.inp 3,915 11-18-2019 11:46 3fa1f209 ha_na245e2c51g1s1000hx.out 651,250 11-19-2019 09:53 5a4ca3be ha_na245e2c51g1s1100hx.inp 3,915 11-18-2019 11:46 3a65269c ha_na245e2c51g1s1100hx.out 650,701 11-19-2019 09:49 c99dc90f ha_na245e2c51g1s1200hx.inp 3,915 11-18-2019 11:47 debfb430 ha_na245e2c51g1s1200hx.out 650,592 11-19-2019 09:50 6f015bcd ha_na245e2c51g1s1300hx.inp 3,915 11-18-2019 11:47 d3dfd81a ha_na245e2c51g1s1300hx.out 650,531 11-19-2019 09:58 779f3d85 ha_na245e2c51g1s1400hx.inp 3,915 11-18-2019 11:47 603d54c2 ha_na245e2c51g1s1400hx.out 650,520 11-19-2019 09:58 192e1701 ha_na245e2c51g1s1500hx.inp 3,915 11-18-2019 11:47 45572789 ha_na245e2c51g1s1500hx.out 650,949 11-19-2019 10:04 5d5daa92
\\v1.2\\ha\\na325\\ (22) 7,189,012 11-20-2019 09:22 ha_na325e2c51g1s0500hx.inp 3,861 11-18-2019 10:42 8aab0310 ha_na325e2c51g1s0500hx.out 649,418 11-19-2019 01:52 497b72ed ha_na325e2c51g1s0600hx.inp 3,861 11-18-2019 10:42 34173439 ha_na325e2c51g1s0600hx.out 648,969 11-19-2019 01:49 42e3586f ha_na325e2c51g1s0700hx.inp 3,861 11-18-2019 10:42 b5f9b3ab ha_na325e2c51g1s0700hx.out 649,215 11-19-2019 01:53 9affb990 ha_na325e2c51g1s0800hx.inp 3,861 11-18-2019 10:42 e740633a ha_na325e2c51g1s0800hx.out 649,174 11-19-2019 01:54 56558211 ha_na325e2c51g1s0900hx.inp 3,861 11-18-2019 10:42 740efc17 ha_na325e2c51g1s0900hx.out 649,601 11-19-2019 01:52 7fb26fc2 ha_na325e2c51g1s1000hx.inp 3,865 11-18-2019 10:43 debe1bbb ha_na325e2c51g1s1000hx.out 649,525 11-19-2019 01:57 d8292375 ha_na325e2c51g1s1100hx.inp 3,865 11-18-2019 10:43 9efdbe80 ha_na325e2c51g1s1100hx.out 649,950 11-19-2019 01:57 6ce8ac68 ha_na325e2c51g1s1200hx.inp 3,865 11-18-2019 10:43 eaa58cee ha_na325e2c51g1s1200hx.out 649,966 11-19-2019 01:55 5c6e06fa ha_na325e2c51g1s1300hx.inp 3,865 11-18-2019 10:43 40752805 ha_na325e2c51g1s1300hx.out 649,779 11-19-2019 02:04 436debd7
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
163 of 190 ha_na325e2c51g1s1400hx.inp 3,865 11-18-2019 10:43 f36d97ff ha_na325e2c51g1s1400hx.out 650,107 11-19-2019 02:01 776acb93 ha_na325e2c51g1s1500hx.inp 3,865 11-18-2019 10:43 ce0a7c6d ha_na325e2c51g1s1500hx.out 650,813 11-19-2019 02:06 7c47c3c2
\\v1.2\\ha\\ns245\\ (22) 7,202,609 11-20-2019 09:22 ha_ns245e2c51g1s0500hx.inp 3,911 11-18-2019 17:28 023fdf6b ha_ns245e2c51g1s0500hx.out 650,915 11-20-2019 06:34 3752c0aa ha_ns245e2c51g1s0600hx.inp 3,912 11-18-2019 17:28 3bdc98df ha_ns245e2c51g1s0600hx.out 650,728 11-20-2019 07:18 7bfd13b1 ha_ns245e2c51g1s0700hx.inp 3,912 11-18-2019 17:28 ee99a3ad ha_ns245e2c51g1s0700hx.out 650,656 11-20-2019 06:53 0732ad45 ha_ns245e2c51g1s0800hx.inp 3,912 11-18-2019 17:28 93c7bb90 ha_ns245e2c51g1s0800hx.out 650,013 11-20-2019 07:15 46f923ca ha_ns245e2c51g1s0900hx.inp 3,912 11-18-2019 17:28 bebb9162 ha_ns245e2c51g1s0900hx.out 650,477 11-20-2019 06:37 3cb39829 ha_ns245e2c51g1s1000hx.inp 3,916 11-18-2019 17:28 9043bc80 ha_ns245e2c51g1s1000hx.out 651,033 11-20-2019 07:07 3ef3f827 ha_ns245e2c51g1s1100hx.inp 3,916 11-18-2019 17:28 52c4ffd3 ha_ns245e2c51g1s1100hx.out 650,589 11-20-2019 06:35 1d3dbfe4 ha_ns245e2c51g1s1200hx.inp 3,916 11-18-2019 17:29 49be98a3 ha_ns245e2c51g1s1200hx.out 650,986 11-20-2019 06:33 e21980b3 ha_ns245e2c51g1s1300hx.inp 3,916 11-18-2019 17:29 c78555eb ha_ns245e2c51g1s1300hx.out 651,978 11-20-2019 06:31 abba0e78 ha_ns245e2c51g1s1400hx.inp 3,916 11-18-2019 17:29 b1ed004b ha_ns245e2c51g1s1400hx.out 649,969 11-20-2019 07:06 eed211db ha_ns245e2c51g1s1500hx.inp 3,916 11-18-2019 17:29 c618fce2 ha_ns245e2c51g1s1500hx.out 652,210 11-20-2019 07:29 a22bbb38
\\v1.2\\ha\\ns325\\ (22) 7,191,962 11-20-2019 09:22 ha_ns325e2c51g1s0500hx.inp 3,862 11-18-2019 16:23 fe899397 ha_ns325e2c51g1s0500hx.out 650,143 11-20-2019 02:27 95052b9b ha_ns325e2c51g1s0600hx.inp 3,862 11-18-2019 16:23 bf7a7c37 ha_ns325e2c51g1s0600hx.out 649,451 11-20-2019 02:13 1d11b936 ha_ns325e2c51g1s0700hx.inp 3,862 11-18-2019 16:23 bd7d8cd6 ha_ns325e2c51g1s0700hx.out 650,312 11-20-2019 02:22 86118848 ha_ns325e2c51g1s0800hx.inp 3,862 11-18-2019 16:23 3675c90c ha_ns325e2c51g1s0800hx.out 649,859 11-20-2019 02:17 25900e40 ha_ns325e2c51g1s0900hx.inp 3,862 11-18-2019 16:23 91acc070 ha_ns325e2c51g1s0900hx.out 649,565 11-20-2019 02:17 3ac4e5b9 ha_ns325e2c51g1s1000hx.inp 3,866 11-18-2019 16:23 531c8e09 ha_ns325e2c51g1s1000hx.out 651,024 11-20-2019 02:19 94973254 ha_ns325e2c51g1s1100hx.inp 3,866 11-18-2019 16:24 f2a529cd ha_ns325e2c51g1s1100hx.out 650,478 11-20-2019 02:21 81751b8f ha_ns325e2c51g1s1200hx.inp 3,866 11-18-2019 16:24 0b50b49b ha_ns325e2c51g1s1200hx.out 648,976 11-20-2019 02:24 cb1278a5 ha_ns325e2c51g1s1300hx.inp 3,866 11-18-2019 16:24 292f7245 ha_ns325e2c51g1s1300hx.out 649,811 11-20-2019 02:41 dbb9d705 ha_ns325e2c51g1s1400hx.inp 3,866 11-18-2019 16:24 bbf6c58d ha_ns325e2c51g1s1400hx.out 649,476 11-20-2019 02:34 38f6f6ca ha_ns325e2c51g1s1500hx.inp 3,866 11-18-2019 16:24 b76a6622 ha_ns325e2c51g1s1500hx.out 650,361 11-20-2019 02:33 11273ba0
\\v1.2\\hb\\ (0) 49,528,237 11-18-2019 17:29
\\v1.2\\hb\\ha245\\ (22) 7,202,176 11-18-2019 20:33 hb_ha245e2c51g1s0500hx.inp 3,890 11-18-2019 02:32 74fddd56 hb_ha245e2c51g1s0500hx.out 650,629 11-18-2019 18:28 2a2dd547 hb_ha245e2c51g1s0600hx.inp 3,891 11-18-2019 02:32 0d1cae03 hb_ha245e2c51g1s0600hx.out 650,966 11-18-2019 18:16 ebf26cb7 hb_ha245e2c51g1s0700hx.inp 3,891 11-18-2019 02:32 b0588cbb hb_ha245e2c51g1s0700hx.out 651,246 11-18-2019 18:35 436596f5 hb_ha245e2c51g1s0800hx.inp 3,891 11-18-2019 02:32 53657e66 hb_ha245e2c51g1s0800hx.out 651,000 11-18-2019 18:33 c1981db1 hb_ha245e2c51g1s0900hx.inp 3,891 11-18-2019 02:32 6a4f5752 hb_ha245e2c51g1s0900hx.out 651,228 11-18-2019 18:33 e1c1ad67 hb_ha245e2c51g1s1000hx.inp 3,895 11-18-2019 02:32 4d5de732 hb_ha245e2c51g1s1000hx.out 649,992 11-18-2019 18:18 bb31316c hb_ha245e2c51g1s1100hx.inp 3,895 11-18-2019 02:32 99c496ac hb_ha245e2c51g1s1100hx.out 650,583 11-18-2019 18:25 306f22ec hb_ha245e2c51g1s1200hx.inp 3,895 11-18-2019 02:32 38086a9e hb_ha245e2c51g1s1200hx.out 650,841 11-18-2019 18:21 1d843a33 hb_ha245e2c51g1s1300hx.inp 3,895 11-18-2019 02:32 6737a861 hb_ha245e2c51g1s1300hx.out 651,455 11-18-2019 18:12 2205fd83 hb_ha245e2c51g1s1400hx.inp 3,895 11-18-2019 02:32 f231690e hb_ha245e2c51g1s1400hx.out 650,831 11-18-2019 18:37 d2bd55f7 hb_ha245e2c51g1s1500hx.inp 3,895 11-18-2019 02:33 3869d8b7
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
164 of 190 hb_ha245e2c51g1s1500hx.out 650,581 11-18-2019 18:14 3926b770
\\v1.2\\hb\\ha325\\ (22) 7,187,295 11-18-2019 20:33 hb_ha325e2c51g1s0500hx.inp 3,836 11-18-2019 01:16 3d8e49a8 hb_ha325e2c51g1s0500hx.out 649,316 11-18-2019 06:28 fc30e83b hb_ha325e2c51g1s0600hx.inp 3,836 11-18-2019 01:16 d9f7e623 hb_ha325e2c51g1s0600hx.out 649,993 11-18-2019 06:42 6222a929 hb_ha325e2c51g1s0700hx.inp 3,836 11-18-2019 01:16 d67800b6 hb_ha325e2c51g1s0700hx.out 649,414 11-18-2019 06:25 4f36614d hb_ha325e2c51g1s0800hx.inp 3,836 11-18-2019 01:16 5b004b67 hb_ha325e2c51g1s0800hx.out 648,732 11-18-2019 06:26 0a1fe3da hb_ha325e2c51g1s0900hx.inp 3,836 11-18-2019 01:17 ed4e5537 hb_ha325e2c51g1s0900hx.out 649,329 11-18-2019 06:33 b7ac271a hb_ha325e2c51g1s1000hx.inp 3,840 11-18-2019 01:17 454937d2 hb_ha325e2c51g1s1000hx.out 650,075 11-18-2019 06:27 45ba636a hb_ha325e2c51g1s1100hx.inp 3,840 11-18-2019 01:17 8f93ec07 hb_ha325e2c51g1s1100hx.out 649,257 11-18-2019 06:44 c8eafdaf hb_ha325e2c51g1s1200hx.inp 3,840 11-18-2019 01:17 1b0434a4 hb_ha325e2c51g1s1200hx.out 649,777 11-18-2019 06:33 05da9b3b hb_ha325e2c51g1s1300hx.inp 3,840 11-18-2019 01:17 9575dc0c hb_ha325e2c51g1s1300hx.out 649,875 11-18-2019 06:32 dfc966e4 hb_ha325e2c51g1s1400hx.inp 3,840 11-18-2019 01:17 c6537373 hb_ha325e2c51g1s1400hx.out 649,774 11-18-2019 06:33 e6780939 hb_ha325e2c51g1s1500hx.inp 3,840 11-18-2019 01:17 a73f5c3f hb_ha325e2c51g1s1500hx.out 649,533 11-18-2019 06:39 1cce629d
\\v1.2\\hb\\hs245\\ (22) 5,593,642 11-20-2019 09:22 hb_hs245e2c51g1s0500hx.inp 3,918 11-18-2019 14:57 7362ad41 hb_hs245e2c51g1s0500hx.out 503,555 11-19-2019 20:59 53f76beb hb_hs245e2c51g1s0600hx.inp 3,919 11-18-2019 14:57 b78fbd29 hb_hs245e2c51g1s0600hx.out 505,446 11-19-2019 21:06 eee8a378 hb_hs245e2c51g1s0700hx.inp 3,919 11-18-2019 14:57 f3c74137 hb_hs245e2c51g1s0700hx.out 504,222 11-19-2019 20:57 90984b24 hb_hs245e2c51g1s0800hx.inp 3,919 11-18-2019 14:57 6f45e39c hb_hs245e2c51g1s0800hx.out 504,907 11-19-2019 20:57 03aa0cb5 hb_hs245e2c51g1s0900hx.inp 3,919 11-18-2019 14:57 3d8e663b hb_hs245e2c51g1s0900hx.out 503,773 11-19-2019 21:05 2ec81a73 hb_hs245e2c51g1s1000hx.inp 3,923 11-18-2019 14:58 3e8d6de9 hb_hs245e2c51g1s1000hx.out 505,055 11-19-2019 21:04 3bc52dcc hb_hs245e2c51g1s1100hx.inp 3,923 11-18-2019 14:58 948fa0a5 hb_hs245e2c51g1s1100hx.out 505,001 11-19-2019 21:07 8eed1d3b hb_hs245e2c51g1s1200hx.inp 3,923 11-18-2019 14:58 6acd453e hb_hs245e2c51g1s1200hx.out 504,121 11-19-2019 21:09 4602a8ee hb_hs245e2c51g1s1300hx.inp 3,923 11-18-2019 14:58 d86b6cc3 hb_hs245e2c51g1s1300hx.out 504,967 11-19-2019 21:10 d31e8084 hb_hs245e2c51g1s1400hx.inp 3,923 11-18-2019 14:58 39ff1def hb_hs245e2c51g1s1400hx.out 504,668 11-19-2019 21:12 5843bafe hb_hs245e2c51g1s1500hx.inp 3,923 11-18-2019 14:58 dd401ccb hb_hs245e2c51g1s1500hx.out 504,795 11-19-2019 21:24 acb5f2c5
\\v1.2\\hb\\hs325\\ (22) 5,871,586 11-20-2019 09:22 hb_hs325e2c51g1s0500hx.inp 3,869 11-18-2019 13:09 6f819274 hb_hs325e2c51g1s0500hx.out 503,259 11-19-2019 15:51 48a72687 hb_hs325e2c51g1s0600hx.inp 3,869 11-18-2019 13:09 852f3f1f hb_hs325e2c51g1s0600hx.out 502,785 11-19-2019 15:49 142dfe41 hb_hs325e2c51g1s0700hx.inp 3,869 11-18-2019 13:09 3bfad176 hb_hs325e2c51g1s0700hx.out 503,090 11-19-2019 15:42 dc359a8b hb_hs325e2c51g1s0800hx.inp 3,869 11-18-2019 13:09 803e803e hb_hs325e2c51g1s0800hx.out 503,550 11-19-2019 15:58 82b8ab56 hb_hs325e2c51g1s0900hx.inp 3,869 11-18-2019 13:09 c97039d9 hb_hs325e2c51g1s0900hx.out 503,304 11-19-2019 15:55 3b5ffe1d hb_hs325e2c51g1s1000hx.inp 3,873 11-18-2019 13:09 8a3c476a hb_hs325e2c51g1s1000hx.out 503,337 11-19-2019 15:56 e4f763a8 hb_hs325e2c51g1s1100hx.inp 3,873 11-18-2019 13:10 679aee2d hb_hs325e2c51g1s1100hx.out 503,732 11-19-2019 15:58 222a7893 hb_hs325e2c51g1s1200hx.inp 3,873 11-18-2019 13:10 0e5bd9fd hb_hs325e2c51g1s1200hx.out 502,365 11-19-2019 15:54 67164bb3 hb_hs325e2c51g1s1300hx.inp 3,873 11-18-2019 13:10 cbaea76e hb_hs325e2c51g1s1300hx.out 504,385 11-19-2019 15:59 b38625cc hb_hs325e2c51g1s1400hx.inp 3,873 11-18-2019 13:10 07423218 hb_hs325e2c51g1s1400hx.out 650,397 11-19-2019 15:55 fb644e96 hb_hs325e2c51g1s1500hx.inp 3,873 11-18-2019 13:10 fcbfc483 hb_hs325e2c51g1s1500hx.out 648,799 11-19-2019 16:04 1a547935
\\v1.2\\hb\\na245\\ (22) 5,593,310 11-20-2019 09:22 hb_na245e2c51g1s0500hx.inp 3,917 11-18-2019 11:47 c48542cc hb_na245e2c51g1s0500hx.out 504,265 11-19-2019 10:01 fd50b131
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
165 of 190 hb_na245e2c51g1s0600hx.inp 3,918 11-18-2019 11:47 c5dd8f33 hb_na245e2c51g1s0600hx.out 504,374 11-19-2019 09:58 33cb4e90 hb_na245e2c51g1s0700hx.inp 3,918 11-18-2019 11:47 22a03be7 hb_na245e2c51g1s0700hx.out 504,752 11-19-2019 09:57 04092f86 hb_na245e2c51g1s0800hx.inp 3,918 11-18-2019 11:47 46f8b088 hb_na245e2c51g1s0800hx.out 504,162 11-19-2019 09:56 236dd4ac hb_na245e2c51g1s0900hx.inp 3,918 11-18-2019 11:47 3c62610d hb_na245e2c51g1s0900hx.out 504,562 11-19-2019 09:52 9ec99b69 hb_na245e2c51g1s1000hx.inp 3,922 11-18-2019 11:47 b21e85ea hb_na245e2c51g1s1000hx.out 505,139 11-19-2019 09:53 22c4f677 hb_na245e2c51g1s1100hx.inp 3,922 11-18-2019 11:48 e94ffb19 hb_na245e2c51g1s1100hx.out 504,562 11-19-2019 09:58 ceb4577f hb_na245e2c51g1s1200hx.inp 3,922 11-18-2019 11:48 eae3e8f2 hb_na245e2c51g1s1200hx.out 504,744 11-19-2019 09:57 b27a348f hb_na245e2c51g1s1300hx.inp 3,922 11-18-2019 11:48 7cd72c52 hb_na245e2c51g1s1300hx.out 504,135 11-19-2019 10:05 ac6467a8 hb_na245e2c51g1s1400hx.inp 3,922 11-18-2019 11:48 52299898 hb_na245e2c51g1s1400hx.out 504,910 11-19-2019 10:03 ad00f04d hb_na245e2c51g1s1500hx.inp 3,922 11-18-2019 11:48 9bb0deae hb_na245e2c51g1s1500hx.out 504,584 11-19-2019 10:02 ad696bae
\\v1.2\\hb\\na325\\ (22) 5,583,501 11-20-2019 09:22 hb_na325e2c51g1s0500hx.inp 3,868 11-18-2019 10:43 f9064c1c hb_na325e2c51g1s0500hx.out 504,047 11-19-2019 02:11 1161b48b hb_na325e2c51g1s0600hx.inp 3,868 11-18-2019 10:43 936e10c1 hb_na325e2c51g1s0600hx.out 504,088 11-19-2019 01:56 f99d114e hb_na325e2c51g1s0700hx.inp 3,868 11-18-2019 10:43 83494477 hb_na325e2c51g1s0700hx.out 502,765 11-19-2019 02:05 e9715633 hb_na325e2c51g1s0800hx.inp 3,868 11-18-2019 10:43 271b3a65 hb_na325e2c51g1s0800hx.out 503,107 11-19-2019 02:05 60d84861 hb_na325e2c51g1s0900hx.inp 3,868 11-18-2019 10:43 bd6f05aa hb_na325e2c51g1s0900hx.out 504,426 11-19-2019 02:01 e9be5f95 hb_na325e2c51g1s1000hx.inp 3,872 11-18-2019 10:43 67de8465 hb_na325e2c51g1s1000hx.out 503,154 11-19-2019 01:56 a4753a37 hb_na325e2c51g1s1100hx.inp 3,872 11-18-2019 10:44 3210d4f5 hb_na325e2c51g1s1100hx.out 503,832 11-19-2019 02:03 ea9884e3 hb_na325e2c51g1s1200hx.inp 3,872 11-18-2019 10:44 c4863b88 hb_na325e2c51g1s1200hx.out 503,329 11-19-2019 02:06 9cd0f6fc hb_na325e2c51g1s1300hx.inp 3,872 11-18-2019 10:44 31168c56 hb_na325e2c51g1s1300hx.out 504,255 11-19-2019 02:02 f26e5c93 hb_na325e2c51g1s1400hx.inp 3,872 11-18-2019 10:44 0d0a8f31 hb_na325e2c51g1s1400hx.out 503,700 11-19-2019 02:13 003b9b91 hb_na325e2c51g1s1500hx.inp 3,872 11-18-2019 10:44 a6930620 hb_na325e2c51g1s1500hx.out 504,226 11-19-2019 02:12 c659b0d7
\\v1.2\\hb\\ns245\\ (22) 5,887,080 11-20-2019 09:22 hb_ns245e2c51g1s0500hx.inp 3,918 11-18-2019 17:29 25a1f52e hb_ns245e2c51g1s0500hx.out 505,061 11-20-2019 06:47 03f63613 hb_ns245e2c51g1s0600hx.inp 3,919 11-18-2019 17:29 583d0f17 hb_ns245e2c51g1s0600hx.out 504,296 11-20-2019 07:20 c3ac0b16 hb_ns245e2c51g1s0700hx.inp 3,919 11-18-2019 17:29 1c75f309 hb_ns245e2c51g1s0700hx.out 504,641 11-20-2019 06:52 d227188c hb_ns245e2c51g1s0800hx.inp 3,919 11-18-2019 17:29 80f751a2 hb_ns245e2c51g1s0800hx.out 504,663 11-20-2019 07:19 a559d342 hb_ns245e2c51g1s0900hx.inp 3,919 11-18-2019 17:29 d23cd405 hb_ns245e2c51g1s0900hx.out 504,737 11-20-2019 07:14 75ca82ee hb_ns245e2c51g1s1000hx.inp 3,923 11-18-2019 17:29 a1c4d2ae hb_ns245e2c51g1s1000hx.out 504,887 11-20-2019 07:20 f8d584d0 hb_ns245e2c51g1s1100hx.inp 3,923 11-18-2019 17:29 0bc61fe2 hb_ns245e2c51g1s1100hx.out 505,407 11-20-2019 07:20 cac228e7 hb_ns245e2c51g1s1200hx.inp 3,923 11-18-2019 17:30 f584fa79 hb_ns245e2c51g1s1200hx.out 504,612 11-20-2019 07:14 e4251b57 hb_ns245e2c51g1s1300hx.inp 3,923 11-18-2019 17:30 4722d384 hb_ns245e2c51g1s1300hx.out 504,815 11-20-2019 07:17 72d02b92 hb_ns245e2c51g1s1400hx.inp 3,923 11-18-2019 17:30 a6b6a2a8 hb_ns245e2c51g1s1400hx.out 650,829 11-20-2019 07:19 d8e81a47 hb_ns245e2c51g1s1500hx.inp 3,923 11-18-2019 17:30 4209a38c hb_ns245e2c51g1s1500hx.out 650,000 11-20-2019 07:17 a0a89d1a
\\v1.2\\hb\\ns325\\ (22) 6,609,647 11-20-2019 09:22 hb_ns325e2c51g1s0500hx.inp 3,869 11-18-2019 16:24 628bc321 hb_ns325e2c51g1s0500hx.out 503,124 11-20-2019 02:25 f9cefb8b hb_ns325e2c51g1s0600hx.inp 3,869 11-18-2019 16:24 88256e4a hb_ns325e2c51g1s0600hx.out 504,277 11-20-2019 02:30 26849d8e hb_ns325e2c51g1s0700hx.inp 3,869 11-18-2019 16:24 36f08023 hb_ns325e2c51g1s0700hx.out 503,223 11-20-2019 02:28 654faa2b hb_ns325e2c51g1s0800hx.inp 3,869 11-18-2019 16:24 8d34d16b hb_ns325e2c51g1s0800hx.out 503,315 11-20-2019 02:25 6afc0811
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
166 of 190 hb_ns325e2c51g1s0900hx.inp 3,869 11-18-2019 16:24 c47a688c hb_ns325e2c51g1s0900hx.out 650,445 11-20-2019 02:30 8e6dda83 hb_ns325e2c51g1s1000hx.inp 3,873 11-18-2019 16:24 e214c4f1 hb_ns325e2c51g1s1000hx.out 650,025 11-20-2019 02:31 736af79f hb_ns325e2c51g1s1100hx.inp 3,873 11-18-2019 16:25 0fb26db6 hb_ns325e2c51g1s1100hx.out 650,866 11-20-2019 02:35 f9799418 hb_ns325e2c51g1s1200hx.inp 3,873 11-18-2019 16:25 66735a66 hb_ns325e2c51g1s1200hx.out 650,456 11-20-2019 02:37 9738f5da hb_ns325e2c51g1s1300hx.inp 3,873 11-18-2019 16:25 a38624f5 hb_ns325e2c51g1s1300hx.out 650,342 11-20-2019 02:39 c167dff8 hb_ns325e2c51g1s1400hx.inp 3,873 11-18-2019 16:25 6f6ab183 hb_ns325e2c51g1s1400hx.out 650,258 11-20-2019 02:40 bc86815f hb_ns325e2c51g1s1500hx.inp 3,873 11-18-2019 16:25 94974718 hb_ns325e2c51g1s1500hx.out 650,733 11-20-2019 02:40 cbc1266b
\\v1.2\\hc\\ (0) 47,104,621 11-18-2019 17:30
\\v1.2\\hc\\ha245\\ (18) 5,892,504 11-22-2019 12:48 hc_ha245e2c51g1s001vfio.inp 3,884 11-18-2019 02:33 902f8bc0 hc_ha245e2c51g1s001vfio.out 650,601 11-18-2019 17:13 65ebf970 hc_ha245e2c51g1s005vfio.inp 3,884 11-18-2019 02:33 2a5c311a hc_ha245e2c51g1s005vfio.out 651,305 11-18-2019 17:05 6e4d2c83 hc_ha245e2c51g1s010vfio.inp 3,884 11-18-2019 02:33 180ee6d3 hc_ha245e2c51g1s010vfio.out 650,650 11-18-2019 17:13 89dc9eef hc_ha245e2c51g1s030vfio.inp 3,884 11-18-2019 02:33 722af619 hc_ha245e2c51g1s030vfio.out 650,882 11-18-2019 17:48 5fcf3366 hc_ha245e2c51g1s050vfio.inp 3,884 11-18-2019 02:33 03adced0 hc_ha245e2c51g1s050vfio.out 651,148 11-18-2019 18:08 0978cb7f hc_ha245e2c51g1s070vfio.inp 3,884 11-18-2019 02:33 12e78139 hc_ha245e2c51g1s070vfio.out 652,379 11-18-2019 18:28 f857fb2a hc_ha245e2c51g1s090vfio.inp 3,884 11-18-2019 02:33 0af9db26 hc_ha245e2c51g1s090vfio.out 650,627 11-18-2019 18:18 367654c2 hc_ha245e2c51g1s095vfio.inp 3,884 11-18-2019 02:33 2df56422 hc_ha245e2c51g1s095vfio.out 649,951 11-18-2019 18:27 ec3be3dc hc_ha245e2c51g1s100vfio.inp 3,884 11-18-2019 02:33 840d9f3b hc_ha245e2c51g1s100vfio.out 650,005 11-18-2019 18:34 096b2bcd
\\v1.2\\hc\\ha325\\ (18) 5,883,786 11-22-2019 12:48 hc_ha325e2c51g1s001vfio.inp 3,829 11-18-2019 01:17 75a063a8 hc_ha325e2c51g1s001vfio.out 649,374 11-18-2019 05:19 50f532a2 hc_ha325e2c51g1s005vfio.inp 3,829 11-18-2019 01:17 d54c4b08 hc_ha325e2c51g1s005vfio.out 650,520 11-18-2019 05:10 dbce9335 hc_ha325e2c51g1s010vfio.inp 3,829 11-18-2019 01:17 3200bb6d hc_ha325e2c51g1s010vfio.out 649,825 11-18-2019 05:07 d06c8b63 hc_ha325e2c51g1s030vfio.inp 3,829 11-18-2019 01:17 eff2ed9f hc_ha325e2c51g1s030vfio.out 650,336 11-18-2019 05:56 ba21e127 hc_ha325e2c51g1s050vfio.inp 3,829 11-18-2019 01:17 b9c0871d hc_ha325e2c51g1s050vfio.out 649,186 11-18-2019 06:06 7465cb8c hc_ha325e2c51g1s070vfio.inp 3,829 11-18-2019 01:18 195b4100 hc_ha325e2c51g1s070vfio.out 650,609 11-18-2019 06:14 43c40fb7 hc_ha325e2c51g1s090vfio.inp 3,829 11-18-2019 01:18 8f8f6746 hc_ha325e2c51g1s090vfio.out 649,906 11-18-2019 06:39 69c29979 hc_ha325e2c51g1s095vfio.inp 3,829 11-18-2019 01:18 7b93b97a hc_ha325e2c51g1s095vfio.out 649,465 11-18-2019 06:39 2517ee42 hc_ha325e2c51g1s100vfio.inp 3,829 11-18-2019 01:18 d6ad88ee hc_ha325e2c51g1s100vfio.out 650,104 11-18-2019 06:45 40ff3893
\\v1.2\\hc\\hs245\\ (18) 5,893,678 11-22-2019 12:48 hc_hs245e2c51g1s001vfi.inp 3,912 11-18-2019 14:58 69be9922 hc_hs245e2c51g1s001vfi.out 651,229 11-19-2019 20:42 a6158308 hc_hs245e2c51g1s005vfi.inp 3,912 11-18-2019 14:58 c7646e2f hc_hs245e2c51g1s005vfi.out 651,689 11-19-2019 20:32 fe0d6d7c hc_hs245e2c51g1s010vfi.inp 3,912 11-18-2019 14:58 c5c6aa33 hc_hs245e2c51g1s010vfi.out 650,609 11-19-2019 20:15 e1096bf1 hc_hs245e2c51g1s030vfi.inp 3,912 11-18-2019 14:58 2ca8dce3 hc_hs245e2c51g1s030vfi.out 650,988 11-19-2019 20:45 2ebdb1a7 hc_hs245e2c51g1s050vfi.inp 3,912 11-18-2019 14:58 26086c4b hc_hs245e2c51g1s050vfi.out 650,961 11-19-2019 20:53 0de2a8df hc_hs245e2c51g1s070vfi.inp 3,912 11-18-2019 14:59 ef6063cb hc_hs245e2c51g1s070vfi.out 650,579 11-19-2019 21:01 8c329a73 hc_hs245e2c51g1s090vfi.inp 3,912 11-18-2019 14:59 31075fe1 hc_hs245e2c51g1s090vfi.out 650,475 11-19-2019 21:13 739f3d01 hc_hs245e2c51g1s095vfi.inp 3,912 11-18-2019 14:59 c91b5d7a hc_hs245e2c51g1s095vfi.out 650,783 11-19-2019 21:12 627a5feb hc_hs245e2c51g1s100vfi.inp 3,912 11-18-2019 14:59 dc83fe7f hc_hs245e2c51g1s100vfi.out 651,157 11-19-2019 21:25 98ffdf86
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
167 of 190
\\v1.2\\hc\\hs325\\ (18) 5,882,861 11-22-2019 12:48 hc_hs325e2c51g1s001vfi.inp 3,862 11-18-2019 13:10 cefec5ad hc_hs325e2c51g1s001vfi.out 649,975 11-19-2019 15:27 eac0b3c8 hc_hs325e2c51g1s005vfi.inp 3,862 11-18-2019 13:10 d50fabb3 hc_hs325e2c51g1s005vfi.out 650,520 11-19-2019 15:09 41861c37 hc_hs325e2c51g1s010vfi.inp 3,862 11-18-2019 13:10 46537d4e hc_hs325e2c51g1s010vfi.out 649,747 11-19-2019 15:05 53a64783 hc_hs325e2c51g1s030vfi.inp 3,862 11-18-2019 13:10 79202fc4 hc_hs325e2c51g1s030vfi.out 649,854 11-19-2019 15:16 52c6d155 hc_hs325e2c51g1s050vfi.inp 3,862 11-18-2019 13:10 80bf63d7 hc_hs325e2c51g1s050vfi.out 649,072 11-19-2019 15:38 5b8dab0b hc_hs325e2c51g1s070vfi.inp 3,862 11-18-2019 13:10 2b644dc5 hc_hs325e2c51g1s070vfi.out 650,310 11-19-2019 15:49 52d86312 hc_hs325e2c51g1s090vfi.inp 3,862 11-18-2019 13:10 fc35d550 hc_hs325e2c51g1s090vfi.out 649,450 11-19-2019 15:59 1ea52874 hc_hs325e2c51g1s095vfi.inp 3,862 11-18-2019 13:11 ce70cf69 hc_hs325e2c51g1s095vfi.out 649,665 11-19-2019 15:58 4520b738 hc_hs325e2c51g1s100vfi.inp 3,862 11-18-2019 13:11 a1615256 hc_hs325e2c51g1s100vfi.out 649,510 11-19-2019 16:03 7d93e98e
\\v1.2\\hc\\na245\\ (18) 5,893,798 11-22-2019 12:48 hc_na245e2c51g1s001vfio.inp 3,911 11-18-2019 11:48 755d5feb hc_na245e2c51g1s001vfio.out 650,979 11-19-2019 08:41 ebe74b16 hc_na245e2c51g1s005vfio.inp 3,911 11-18-2019 11:48 ab24ae25 hc_na245e2c51g1s005vfio.out 650,271 11-19-2019 08:36 735864f7 hc_na245e2c51g1s010vfio.inp 3,911 11-18-2019 11:48 9ec38564 hc_na245e2c51g1s010vfio.out 650,757 11-19-2019 08:43 d6bf1b51 hc_na245e2c51g1s030vfio.inp 3,911 11-18-2019 11:48 3def23d1 hc_na245e2c51g1s030vfio.out 650,662 11-19-2019 09:31 7babdf17 hc_na245e2c51g1s050vfio.inp 3,911 11-18-2019 11:48 30ffe74a hc_na245e2c51g1s050vfio.out 650,778 11-19-2019 09:49 c2b9c4b3 hc_na245e2c51g1s070vfio.inp 3,911 11-18-2019 11:48 8a083485 hc_na245e2c51g1s070vfio.out 651,578 11-19-2019 10:00 1c3a9277 hc_na245e2c51g1s090vfio.inp 3,911 11-18-2019 11:49 9a323b30 hc_na245e2c51g1s090vfio.out 651,461 11-19-2019 10:01 5c8f7e14 hc_na245e2c51g1s095vfio.inp 3,911 11-18-2019 11:49 9daafced hc_na245e2c51g1s095vfio.out 650,638 11-19-2019 10:03 4e2ef6d3 hc_na245e2c51g1s100vfio.inp 3,911 11-18-2019 11:49 a1504a74 hc_na245e2c51g1s100vfio.out 651,475 11-19-2019 10:04 95efecbf
\\v1.2\\hc\\na325\\ (18) 5,884,129 11-22-2019 12:48 hc_na325e2c51g1s001vfio.inp 3,861 11-18-2019 10:44 f0f5bb06 hc_na325e2c51g1s001vfio.out 650,561 11-19-2019 00:47 77cbd94e hc_na325e2c51g1s005vfio.inp 3,861 11-18-2019 10:44 a68d79af hc_na325e2c51g1s005vfio.out 649,151 11-19-2019 00:35 c701fa67 hc_na325e2c51g1s010vfio.inp 3,861 11-18-2019 10:44 2a8325f3 hc_na325e2c51g1s010vfio.out 651,328 11-19-2019 00:43 eee30fbd hc_na325e2c51g1s030vfio.inp 3,861 11-18-2019 10:44 d41c0140 hc_na325e2c51g1s030vfio.out 649,693 11-19-2019 01:22 8aff4e7c hc_na325e2c51g1s050vfio.inp 3,861 11-18-2019 10:44 3ae3c4f0 hc_na325e2c51g1s050vfio.out 649,233 11-19-2019 01:43 7bb3f7f1 hc_na325e2c51g1s070vfio.inp 3,861 11-18-2019 10:44 6dd2fae2 hc_na325e2c51g1s070vfio.out 649,548 11-19-2019 01:56 497afee4 hc_na325e2c51g1s090vfio.inp 3,861 11-18-2019 10:45 32a9ec66 hc_na325e2c51g1s090vfio.out 650,081 11-19-2019 02:08 0b75b256 hc_na325e2c51g1s095vfio.inp 3,861 11-18-2019 10:45 88085920 hc_na325e2c51g1s095vfio.out 650,184 11-19-2019 01:59 5a6bae3f hc_na325e2c51g1s100vfio.inp 3,861 11-18-2019 10:45 740efc17 hc_na325e2c51g1s100vfio.out 649,601 11-19-2019 02:05 b2103723
\\v1.2\\hc\\ns245\\ (18) 5,893,568 11-22-2019 12:48 hc_ns245e2c51g1s001vfi.inp 3,912 11-18-2019 17:30 0b86f63f hc_ns245e2c51g1s001vfi.out 650,994 11-20-2019 07:13 7f1f112a hc_ns245e2c51g1s005vfi.inp 3,912 11-18-2019 17:30 a55c0132 hc_ns245e2c51g1s005vfi.out 650,671 11-20-2019 06:54 2eb3a403 hc_ns245e2c51g1s010vfi.inp 3,912 11-18-2019 17:30 a7fec52e hc_ns245e2c51g1s010vfi.out 649,933 11-20-2019 06:45 1204aec2 hc_ns245e2c51g1s030vfi.inp 3,912 11-18-2019 17:30 4e90b3fe hc_ns245e2c51g1s030vfi.out 651,320 11-20-2019 07:12 8fa456a6 hc_ns245e2c51g1s050vfi.inp 3,912 11-18-2019 17:30 44300356 hc_ns245e2c51g1s050vfi.out 652,035 11-20-2019 07:16 f03fe53f hc_ns245e2c51g1s070vfi.inp 3,912 11-18-2019 17:30 8d580cd6 hc_ns245e2c51g1s070vfi.out 651,137 11-20-2019 08:04 3b8e1859 hc_ns245e2c51g1s090vfi.inp 3,912 11-18-2019 17:30 533f30fc hc_ns245e2c51g1s090vfi.out 651,103 11-20-2019 07:25 b12e0d51 hc_ns245e2c51g1s095vfi.inp 3,912 11-18-2019 17:31 ab233267 hc_ns245e2c51g1s095vfi.out 650,690 11-20-2019 07:14 6ca211ec
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
168 of 190 hc_ns245e2c51g1s100vfi.inp 3,912 11-18-2019 17:31 bebb9162 hc_ns245e2c51g1s100vfi.out 650,477 11-20-2019 07:25 5e2ce185
\\v1.2\\hc\\ns325\\ (18) 5,880,297 11-22-2019 12:48 hc_ns325e2c51g1s001vfi.inp 3,862 11-18-2019 16:25 fe33578b hc_ns325e2c51g1s001vfi.out 650,112 11-20-2019 02:07 6c3a0219 hc_ns325e2c51g1s005vfi.inp 3,862 11-18-2019 16:25 e5c23995 hc_ns325e2c51g1s005vfi.out 649,039 11-20-2019 01:45 63110b2e hc_ns325e2c51g1s010vfi.inp 3,862 11-18-2019 16:25 769eef68 hc_ns325e2c51g1s010vfi.out 649,871 11-20-2019 01:43 c19bbdd3 hc_ns325e2c51g1s030vfi.inp 3,862 11-18-2019 16:25 49edbde2 hc_ns325e2c51g1s030vfi.out 648,981 11-20-2019 02:02 22b1118c hc_ns325e2c51g1s050vfi.inp 3,862 11-18-2019 16:25 b072f1f1 hc_ns325e2c51g1s050vfi.out 649,785 11-20-2019 02:21 ee6497b9 hc_ns325e2c51g1s070vfi.inp 3,862 11-18-2019 16:25 1ba9dfe3 hc_ns325e2c51g1s070vfi.out 649,484 11-20-2019 02:28 1fe9dc25 hc_ns325e2c51g1s090vfi.inp 3,862 11-18-2019 16:26 ccf84776 hc_ns325e2c51g1s090vfi.out 649,386 11-20-2019 02:29 0c7aac51 hc_ns325e2c51g1s095vfi.inp 3,862 11-18-2019 16:26 febd5d4f hc_ns325e2c51g1s095vfi.out 649,314 11-20-2019 02:37 5b63950d hc_ns325e2c51g1s100vfi.inp 3,862 11-18-2019 16:26 91acc070 hc_ns325e2c51g1s100vfi.out 649,567 11-20-2019 02:36 94f7eed8
\\v1.2\\hd\\ (0) 40,527,874 11-18-2019 17:31
\\v1.2\\hd\\ha245\\ (18) 5,892,023 11-22-2019 12:48 hd_ha245e2c51g1s001vfio.inp 3,891 11-18-2019 02:34 f866463f hd_ha245e2c51g1s001vfio.out 650,439 11-18-2019 17:24 f435d386 hd_ha245e2c51g1s005vfio.inp 3,891 11-18-2019 02:34 f76348c8 hd_ha245e2c51g1s005vfio.out 650,434 11-18-2019 17:09 d7e1a940 hd_ha245e2c51g1s010vfio.inp 3,891 11-18-2019 02:34 b4c3b431 hd_ha245e2c51g1s010vfio.out 650,591 11-18-2019 17:21 bc9908e6 hd_ha245e2c51g1s030vfio.inp 3,891 11-18-2019 02:34 63f164d7 hd_ha245e2c51g1s030vfio.out 651,838 11-18-2019 17:52 187f879d hd_ha245e2c51g1s050vfio.inp 3,891 11-18-2019 02:34 8ca238d5 hd_ha245e2c51g1s050vfio.out 650,500 11-18-2019 18:16 d5e303c3 hd_ha245e2c51g1s070vfio.inp 3,891 11-18-2019 02:34 9150bf9a hd_ha245e2c51g1s070vfio.out 651,114 11-18-2019 18:29 87e36362 hd_ha245e2c51g1s090vfio.inp 3,891 11-18-2019 02:34 832ca4f8 hd_ha245e2c51g1s090vfio.out 650,282 11-18-2019 18:28 d8769e38 hd_ha245e2c51g1s095vfio.inp 3,891 11-18-2019 02:34 985f3650 hd_ha245e2c51g1s095vfio.out 650,575 11-18-2019 18:33 69759994 hd_ha245e2c51g1s100vfio.inp 3,891 11-18-2019 02:34 6a4f5752 hd_ha245e2c51g1s100vfio.out 651,231 11-18-2019 18:36 8dc37dba
\\v1.2\\hd\\ha325\\ (18) 5,882,719 11-22-2019 12:48 hd_ha325e2c51g1s001vfio.inp 3,836 11-18-2019 01:18 af175dac hd_ha325e2c51g1s001vfio.out 649,782 11-18-2019 05:34 94571188 hd_ha325e2c51g1s005vfio.inp 3,836 11-18-2019 01:18 e3437c1a hd_ha325e2c51g1s005vfio.out 649,896 11-18-2019 05:17 8fd8a28c hd_ha325e2c51g1s010vfio.inp 3,836 11-18-2019 01:18 904c7938 hd_ha325e2c51g1s010vfio.out 650,285 11-18-2019 05:13 50c35e69 hd_ha325e2c51g1s030vfio.inp 3,836 11-18-2019 01:18 78b2b3c0 hd_ha325e2c51g1s030vfio.out 649,386 11-18-2019 05:50 44177eee hd_ha325e2c51g1s050vfio.inp 3,836 11-18-2019 01:18 cb7195b5 hd_ha325e2c51g1s050vfio.out 649,456 11-18-2019 06:10 4c6497e6 hd_ha325e2c51g1s070vfio.inp 3,836 11-18-2019 01:18 f3b913bf hd_ha325e2c51g1s070vfio.out 649,775 11-18-2019 06:27 a810b9ce hd_ha325e2c51g1s090vfio.inp 3,836 11-18-2019 01:18 3805bcc4 hd_ha325e2c51g1s090vfio.out 650,066 11-18-2019 06:47 5deaeb69 hd_ha325e2c51g1s095vfio.inp 3,836 11-18-2019 01:19 75e23c3b hd_ha325e2c51g1s095vfio.out 650,218 11-18-2019 06:46 961ebbd2 hd_ha325e2c51g1s100vfio.inp 3,836 11-18-2019 01:19 ed4e5537 hd_ha325e2c51g1s100vfio.out 649,331 11-18-2019 06:33 9b49acaa
\\v1.2\\hd\\hs245\\ (18) 4,576,375 11-22-2019 12:48 hd_hs245e2c51g1s001vfi.inp 3,919 11-18-2019 14:59 a577154b hd_hs245e2c51g1s001vfi.out 504,494 11-19-2019 20:45 15ea1442 hd_hs245e2c51g1s005vfi.inp 3,919 11-18-2019 14:59 5587b98f hd_hs245e2c51g1s005vfi.out 505,230 11-19-2019 20:25 3870b149 hd_hs245e2c51g1s010vfi.inp 3,919 11-18-2019 14:59 06959109 hd_hs245e2c51g1s010vfi.out 504,302 11-19-2019 20:20 23f7b86a hd_hs245e2c51g1s030vfi.inp 3,919 11-18-2019 14:59 5406017b hd_hs245e2c51g1s030vfi.out 505,175 11-19-2019 20:40 0044b167 hd_hs245e2c51g1s050vfi.inp 3,919 11-18-2019 14:59 663ef307 hd_hs245e2c51g1s050vfi.out 504,754 11-19-2019 20:56 4deaa8ad
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
169 of 190 hd_hs245e2c51g1s070vfi.inp 3,919 11-18-2019 14:59 6005a962 hd_hs245e2c51g1s070vfi.out 504,421 11-19-2019 21:05 54b611b8 hd_hs245e2c51g1s090vfi.inp 3,919 11-18-2019 15:00 dce2bd13 hd_hs245e2c51g1s090vfi.out 504,870 11-19-2019 21:12 ff8fe509 hd_hs245e2c51g1s095vfi.inp 3,919 11-18-2019 15:00 551afc23 hd_hs245e2c51g1s095vfi.out 504,086 11-19-2019 21:10 76bebf4e hd_hs245e2c51g1s100vfi.inp 3,919 11-18-2019 15:00 3d8e663b hd_hs245e2c51g1s100vfi.out 503,772 11-19-2019 21:14 6cd7827b
\\v1.2\\hd\\hs325\\ (18) 4,568,809 11-22-2019 12:48 hd_hs325e2c51g1s001vfi.inp 3,869 11-18-2019 13:11 22a04171 hd_hs325e2c51g1s001vfi.out 503,241 11-19-2019 15:34 c50eee39 hd_hs325e2c51g1s005vfi.inp 3,869 11-18-2019 13:11 a667aebb hd_hs325e2c51g1s005vfi.out 504,240 11-19-2019 15:12 021a5365 hd_hs325e2c51g1s010vfi.inp 3,869 11-18-2019 13:11 bbbde7ce hd_hs325e2c51g1s010vfi.out 503,943 11-19-2019 15:08 93f3fbbd hd_hs325e2c51g1s030vfi.inp 3,869 11-18-2019 13:11 f67bbcd6 hd_hs325e2c51g1s030vfi.out 504,488 11-19-2019 15:26 aaf7691a hd_hs325e2c51g1s050vfi.inp 3,869 11-18-2019 13:11 3ffc5836 hd_hs325e2c51g1s050vfi.out 503,482 11-19-2019 15:44 7e582a5a hd_hs325e2c51g1s070vfi.inp 3,869 11-18-2019 13:11 f24f6c69 hd_hs325e2c51g1s070vfi.out 503,434 11-19-2019 15:57 b149a1fb hd_hs325e2c51g1s090vfi.inp 3,869 11-18-2019 13:11 67ddbab9 hd_hs325e2c51g1s090vfi.out 503,929 11-19-2019 16:01 1abf289c hd_hs325e2c51g1s095vfi.inp 3,869 11-18-2019 13:11 8396271a hd_hs325e2c51g1s095vfi.out 503,927 11-19-2019 16:02 e7fe91c2 hd_hs325e2c51g1s100vfi.inp 3,869 11-18-2019 13:12 c97039d9 hd_hs325e2c51g1s100vfi.out 503,304 11-19-2019 16:05 db2c2046
\\v1.2\\hd\\na245\\ (18) 4,579,170 11-22-2019 12:48 hd_na245e2c51g1s001vfio.inp 3,918 11-18-2019 11:49 2f329de0 hd_na245e2c51g1s001vfio.out 505,596 11-19-2019 08:54 860e88a0 hd_na245e2c51g1s005vfio.inp 3,918 11-18-2019 11:49 28cda990 hd_na245e2c51g1s005vfio.out 505,522 11-19-2019 08:45 15825708 hd_na245e2c51g1s010vfio.inp 3,918 11-18-2019 11:49 f7349743 hd_na245e2c51g1s010vfio.out 504,665 11-19-2019 08:53 8ff12020 hd_na245e2c51g1s030vfio.inp 3,918 11-18-2019 11:49 cd80fd42 hd_na245e2c51g1s030vfio.out 504,739 11-19-2019 09:33 e4a14150 hd_na245e2c51g1s050vfio.inp 3,918 11-18-2019 11:49 b6066498 hd_na245e2c51g1s050vfio.out 504,369 11-19-2019 09:58 877c0047 hd_na245e2c51g1s070vfio.inp 3,918 11-18-2019 11:49 1f006be8 hd_na245e2c51g1s070vfio.out 505,569 11-19-2019 09:45 4a74a90f hd_na245e2c51g1s090vfio.inp 3,918 11-18-2019 11:50 4311c4c5 hd_na245e2c51g1s090vfio.out 504,508 11-19-2019 10:04 ec411960 hd_na245e2c51g1s095vfio.inp 3,918 11-18-2019 11:50 05fcb1b9 hd_na245e2c51g1s095vfio.out 504,376 11-19-2019 10:13 ee5ab530 hd_na245e2c51g1s100vfio.inp 3,918 11-18-2019 11:50 3c62610d hd_na245e2c51g1s100vfio.out 504,564 11-19-2019 10:17 b93bfd28
\\v1.2\\hd\\na325\\ (18) 4,568,665 11-22-2019 12:48 hd_na325e2c51g1s001vfio.inp 3,868 11-18-2019 10:45 8d0b39e7 hd_na325e2c51g1s001vfio.out 504,504 11-19-2019 00:55 346e5dd3 hd_na325e2c51g1s005vfio.inp 3,868 11-18-2019 10:45 6493adcd hd_na325e2c51g1s005vfio.out 503,793 11-19-2019 00:39 d55f5cfa hd_na325e2c51g1s010vfio.inp 3,868 11-18-2019 10:45 8aade2d0 hd_na325e2c51g1s010vfio.out 503,875 11-19-2019 00:52 460752ae hd_na325e2c51g1s030vfio.inp 3,868 11-18-2019 10:45 15e04903 hd_na325e2c51g1s030vfio.out 503,163 11-19-2019 01:26 dbdd5468 hd_na325e2c51g1s050vfio.inp 3,868 11-18-2019 10:45 b8d63229 hd_na325e2c51g1s050vfio.out 503,264 11-19-2019 01:59 8580f435 hd_na325e2c51g1s070vfio.inp 3,868 11-18-2019 10:45 aeb1f697 hd_na325e2c51g1s070vfio.out 503,924 11-19-2019 01:59 1a16625d hd_na325e2c51g1s090vfio.inp 3,868 11-18-2019 10:45 c3c77928 hd_na325e2c51g1s090vfio.out 503,461 11-19-2019 02:08 b6236209 hd_na325e2c51g1s095vfio.inp 3,868 11-18-2019 10:45 37976a80 hd_na325e2c51g1s095vfio.out 503,444 11-19-2019 02:07 156d66ad hd_na325e2c51g1s100vfio.inp 3,868 11-18-2019 10:46 bd6f05aa hd_na325e2c51g1s100vfio.out 504,425 11-19-2019 02:20 ad5006d1
\\v1.2\\hd\\ns245\\ (18) 4,576,282 11-22-2019 12:48 hd_ns245e2c51g1s001vfi.inp 3,919 11-18-2019 17:31 4ac5a775 hd_ns245e2c51g1s001vfi.out 504,849 11-20-2019 07:04 fe1707a8 hd_ns245e2c51g1s005vfi.inp 3,919 11-18-2019 17:31 ba350bb1 hd_ns245e2c51g1s005vfi.out 504,607 11-20-2019 06:28 ffb121e5 hd_ns245e2c51g1s010vfi.inp 3,919 11-18-2019 17:31 e9272337 hd_ns245e2c51g1s010vfi.out 504,113 11-20-2019 06:54 b0163e17 hd_ns245e2c51g1s030vfi.inp 3,919 11-18-2019 17:31 bbb4b345
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
170 of 190 hd_ns245e2c51g1s030vfi.out 504,340 11-20-2019 07:06 673f6bda hd_ns245e2c51g1s050vfi.inp 3,919 11-18-2019 17:31 898c4139 hd_ns245e2c51g1s050vfi.out 504,454 11-20-2019 07:27 8e3cdfc8 hd_ns245e2c51g1s070vfi.inp 3,919 11-18-2019 17:31 8fb71b5c hd_ns245e2c51g1s070vfi.out 504,545 11-20-2019 07:31 f7803372 hd_ns245e2c51g1s090vfi.inp 3,919 11-18-2019 17:31 33500f2d hd_ns245e2c51g1s090vfi.out 504,091 11-20-2019 07:21 202ea037 hd_ns245e2c51g1s095vfi.inp 3,919 11-18-2019 17:31 baa84e1d hd_ns245e2c51g1s095vfi.out 505,275 11-20-2019 07:15 3460c368 hd_ns245e2c51g1s100vfi.inp 3,919 11-18-2019 17:32 d23cd405 hd_ns245e2c51g1s100vfi.out 504,737 11-20-2019 07:02 42af1148
\\v1.2\\hd\\ns325\\ (18) 5,883,831 11-22-2019 12:48 hd_ns325e2c51g1s001vfi.inp 3,869 11-18-2019 16:26 2faa1024 hd_ns325e2c51g1s001vfi.out 650,074 11-20-2019 02:10 d3f759fa hd_ns325e2c51g1s005vfi.inp 3,869 11-18-2019 16:26 ab6dffee hd_ns325e2c51g1s005vfi.out 650,646 11-20-2019 01:49 564ad142 hd_ns325e2c51g1s010vfi.inp 3,869 11-18-2019 16:26 b6b7b69b hd_ns325e2c51g1s010vfi.out 649,239 11-20-2019 01:39 8b2a4aa9 hd_ns325e2c51g1s030vfi.inp 3,869 11-18-2019 16:26 fb71ed83 hd_ns325e2c51g1s030vfi.out 649,606 11-20-2019 02:05 30ef53cf hd_ns325e2c51g1s050vfi.inp 3,869 11-18-2019 16:26 32f60963 hd_ns325e2c51g1s050vfi.out 650,116 11-20-2019 02:22 fc5639b5 hd_ns325e2c51g1s070vfi.inp 3,869 11-18-2019 16:26 ff453d3c hd_ns325e2c51g1s070vfi.out 650,199 11-20-2019 02:30 3ff3212e hd_ns325e2c51g1s090vfi.inp 3,869 11-18-2019 16:26 6ad7ebec hd_ns325e2c51g1s090vfi.out 649,717 11-20-2019 02:29 1b18a964 hd_ns325e2c51g1s095vfi.inp 3,869 11-18-2019 16:27 8e9c764f hd_ns325e2c51g1s095vfi.out 648,968 11-20-2019 02:40 11e8fac5 hd_ns325e2c51g1s100vfi.inp 3,869 11-18-2019 16:27 c47a688c hd_ns325e2c51g1s100vfi.out 650,445 11-20-2019 02:41 9c106e7e
\\v1.2\\he\\ (0) 28,598,554 11-18-2019 15:35
\\v1.2\\he\\ha245\\ (22) 7,176,787 11-18-2019 20:33 he_ha245e2c51g1s0500hx.inp 3,569 11-18-2019 09:55 d8305a5c he_ha245e2c51g1s0500hx.out 649,065 11-18-2019 18:43 f53f2119 he_ha245e2c51g1s0600hx.inp 3,570 11-18-2019 09:55 3b7aa5bf he_ha245e2c51g1s0600hx.out 648,773 11-18-2019 18:39 48a29ba6 he_ha245e2c51g1s0700hx.inp 3,570 11-18-2019 09:55 59d6bd03 he_ha245e2c51g1s0700hx.out 649,158 11-18-2019 18:38 377146d8 he_ha245e2c51g1s0800hx.inp 3,570 11-18-2019 09:55 aa8c6204 he_ha245e2c51g1s0800hx.out 649,581 11-18-2019 18:34 e13785cc he_ha245e2c51g1s0900hx.inp 3,570 11-18-2019 09:56 b74b0de0 he_ha245e2c51g1s0900hx.out 648,486 11-18-2019 18:28 53a36f17 he_ha245e2c51g1s1000hx.inp 3,574 11-18-2019 09:56 91b0549c he_ha245e2c51g1s1000hx.out 648,412 11-18-2019 18:35 1b7c93fe he_ha245e2c51g1s1100hx.inp 3,574 11-18-2019 09:56 ca65ee0c he_ha245e2c51g1s1100hx.out 648,252 11-18-2019 18:46 8768a293 he_ha245e2c51g1s1200hx.inp 3,574 11-18-2019 09:56 cfd46dd2 he_ha245e2c51g1s1200hx.out 648,328 11-18-2019 18:43 e1d98e4e he_ha245e2c51g1s1300hx.inp 3,574 11-18-2019 09:56 5ec7d67c he_ha245e2c51g1s1300hx.out 649,934 11-18-2019 18:43 1ab5c778 he_ha245e2c51g1s1400hx.inp 3,574 11-18-2019 09:56 2a9d0f1d he_ha245e2c51g1s1400hx.out 648,791 11-18-2019 18:47 6e58b5f8 he_ha245e2c51g1s1500hx.inp 3,574 11-18-2019 09:56 ffa60bc9 he_ha245e2c51g1s1500hx.out 648,714 11-18-2019 18:44 2c6e43a1
\\v1.2\\he\\ha325\\ (22) 7,198,317 11-18-2019 20:33 he_ha325e2c51g1s0500hx.inp 3,746 11-18-2019 01:26 d8b6f488 he_ha325e2c51g1s0500hx.out 650,922 11-18-2019 06:49 4f68c8d7 he_ha325e2c51g1s0600hx.inp 3,746 11-18-2019 01:26 05ed98e4 he_ha325e2c51g1s0600hx.out 651,503 11-18-2019 06:42 2b77c9fe he_ha325e2c51g1s0700hx.inp 3,746 11-18-2019 01:26 6579c15b he_ha325e2c51g1s0700hx.out 650,360 11-18-2019 06:59 ed8003c2 he_ha325e2c51g1s0800hx.inp 3,746 11-18-2019 01:26 91061a5d he_ha325e2c51g1s0800hx.out 650,484 11-18-2019 06:39 e1f573e5 he_ha325e2c51g1s0900hx.inp 3,746 11-18-2019 01:26 0452581b he_ha325e2c51g1s0900hx.out 650,127 11-18-2019 07:00 bac1a90c he_ha325e2c51g1s1000hx.inp 3,750 11-18-2019 01:26 3bdba4b0 he_ha325e2c51g1s1000hx.out 649,977 11-18-2019 06:40 1835f9fc he_ha325e2c51g1s1100hx.inp 3,750 11-18-2019 01:26 eebcb219 he_ha325e2c51g1s1100hx.out 650,707 11-18-2019 06:46 83a0e889 he_ha325e2c51g1s1200hx.inp 3,750 11-18-2019 01:26 6f591220 he_ha325e2c51g1s1200hx.out 650,607 11-18-2019 06:45 87460dde he_ha325e2c51g1s1300hx.inp 3,750 11-18-2019 01:26 cc10f43a he_ha325e2c51g1s1300hx.out 650,340 11-18-2019 06:43 3f4f4c7e
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
171 of 190 he_ha325e2c51g1s1400hx.inp 3,750 11-18-2019 01:26 417b1efe he_ha325e2c51g1s1400hx.out 652,043 11-18-2019 06:38 b97a4a65 he_ha325e2c51g1s1500hx.inp 3,750 11-18-2019 01:26 4d21729a he_ha325e2c51g1s1500hx.out 650,017 11-18-2019 07:06 34cbcbf2
\\v1.2\\he\\na245\\ (22) 7,025,761 11-20-2019 09:22 he_na245e2c51g1s0500hx.inp 3,569 11-18-2019 12:05 1dd8bbe9 he_na245e2c51g1s0500hx.out 501,517 11-19-2019 10:10 5df4cfc6 he_na245e2c51g1s0600hx.inp 3,570 11-18-2019 12:06 7121c1a7 he_na245e2c51g1s0600hx.out 647,417 11-19-2019 10:11 d9805954 he_na245e2c51g1s0700hx.inp 3,570 11-18-2019 12:06 138dd91b he_na245e2c51g1s0700hx.out 649,163 11-19-2019 10:05 6cdb3e6f he_na245e2c51g1s0800hx.inp 3,570 11-18-2019 12:06 e0d7061c he_na245e2c51g1s0800hx.out 648,423 11-19-2019 10:09 589d0b7a he_na245e2c51g1s0900hx.inp 3,570 11-18-2019 12:06 fd1069f8 he_na245e2c51g1s0900hx.out 648,460 11-19-2019 10:07 aa2b0d62 he_na245e2c51g1s1000hx.inp 3,574 11-18-2019 12:06 10fc0748 he_na245e2c51g1s1000hx.out 648,359 11-19-2019 10:10 fcba4b3e he_na245e2c51g1s1100hx.inp 3,574 11-18-2019 12:06 4b29bdd8 he_na245e2c51g1s1100hx.out 648,724 11-19-2019 10:04 9910c8c7 he_na245e2c51g1s1200hx.inp 3,574 11-18-2019 12:06 4e983e06 he_na245e2c51g1s1200hx.out 648,434 11-19-2019 10:09 63cbbbe9 he_na245e2c51g1s1300hx.inp 3,574 11-18-2019 12:06 df8b85a8 he_na245e2c51g1s1300hx.out 648,551 11-19-2019 10:17 b8d38157 he_na245e2c51g1s1400hx.inp 3,574 11-18-2019 12:06 abd15cc9 he_na245e2c51g1s1400hx.out 648,659 11-19-2019 10:23 3a88c0af he_na245e2c51g1s1500hx.inp 3,574 11-18-2019 12:06 7eea581d he_na245e2c51g1s1500hx.out 648,761 11-19-2019 10:29 af9ace92
\\v1.2\\he\\na325\\ (22) 7,197,689 11-20-2019 09:22 he_na325e2c51g1s0500hx.inp 3,778 11-18-2019 11:01 c8cb73b5 he_na325e2c51g1s0500hx.out 651,386 11-19-2019 02:17 2e233430 he_na325e2c51g1s0600hx.inp 3,778 11-18-2019 11:01 182fcba6 he_na325e2c51g1s0600hx.out 651,217 11-19-2019 02:12 1d000c08 he_na325e2c51g1s0700hx.inp 3,778 11-18-2019 11:01 4236f7d0 he_na325e2c51g1s0700hx.out 651,128 11-19-2019 02:21 0591592b he_na325e2c51g1s0800hx.inp 3,778 11-18-2019 11:01 65661c42 he_na325e2c51g1s0800hx.out 650,584 11-19-2019 02:17 ad787768 he_na325e2c51g1s0900hx.inp 3,778 11-18-2019 11:01 138573d1 he_na325e2c51g1s0900hx.out 650,201 11-19-2019 02:31 0243feff he_na325e2c51g1s1000hx.inp 3,782 11-18-2019 11:01 b634d4e7 he_na325e2c51g1s1000hx.out 649,962 11-19-2019 02:17 4aed604b he_na325e2c51g1s1100hx.inp 3,782 11-18-2019 11:01 0423b902 he_na325e2c51g1s1100hx.out 649,694 11-19-2019 02:24 63722ac5 he_na325e2c51g1s1200hx.inp 3,782 11-18-2019 11:01 c7d28321 he_na325e2c51g1s1200hx.out 650,631 11-19-2019 02:36 e42dbfbd he_na325e2c51g1s1300hx.inp 3,782 11-18-2019 11:01 61700ed7 he_na325e2c51g1s1300hx.out 650,909 11-19-2019 02:28 b8ca6cfe he_na325e2c51g1s1400hx.inp 3,782 11-18-2019 11:01 bd71c764 he_na325e2c51g1s1400hx.out 649,538 11-19-2019 02:28 08f63d72 he_na325e2c51g1s1500hx.inp 3,782 11-18-2019 11:01 3f681fed he_na325e2c51g1s1500hx.out 650,857 11-19-2019 02:38 1cbe7a81
\\v1.2\\hf\\ (0) 25,520,525 11-18-2019 15:35
\\v1.2\\hf\\ha245\\ (22) 7,173,383 11-18-2019 20:33 hf_ha245e2c51g1s0500hx.inp 3,576 11-18-2019 09:56 c3675dc6 hf_ha245e2c51g1s0500hx.out 648,494 11-18-2019 18:45 be46b5e6 hf_ha245e2c51g1s0600hx.inp 3,577 11-18-2019 09:56 f1757283 hf_ha245e2c51g1s0600hx.out 648,209 11-18-2019 18:45 088376b4 hf_ha245e2c51g1s0700hx.inp 3,577 11-18-2019 09:56 83ac00b0 hf_ha245e2c51g1s0700hx.out 648,536 11-18-2019 18:43 48ae3290 hf_ha245e2c51g1s0800hx.inp 3,577 11-18-2019 09:56 1d5a7d8e hf_ha245e2c51g1s0800hx.out 648,669 11-18-2019 18:41 e5dd6d61 hf_ha245e2c51g1s0900hx.inp 3,577 11-18-2019 09:56 1abd507d hf_ha245e2c51g1s0900hx.out 648,262 11-18-2019 18:43 4df9c36d hf_ha245e2c51g1s1000hx.inp 3,581 11-18-2019 09:57 31f73f99 hf_ha245e2c51g1s1000hx.out 648,325 11-18-2019 18:44 b41430c2 hf_ha245e2c51g1s1100hx.inp 3,581 11-18-2019 09:57 a2b8d0ec hf_ha245e2c51g1s1100hx.out 648,476 11-18-2019 18:44 ea5f9c42 hf_ha245e2c51g1s1200hx.inp 3,581 11-18-2019 09:57 4dbad1e9 hf_ha245e2c51g1s1200hx.out 648,233 11-18-2019 18:43 7b6f459f hf_ha245e2c51g1s1300hx.inp 3,581 11-18-2019 09:57 39280bab hf_ha245e2c51g1s1300hx.out 648,599 11-18-2019 18:47 76e3a0fb hf_ha245e2c51g1s1400hx.inp 3,581 11-18-2019 09:57 5610f84f hf_ha245e2c51g1s1400hx.out 649,449 11-18-2019 18:49 b4684521 hf_ha245e2c51g1s1500hx.inp 3,581 11-18-2019 09:57 a6391e74
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
172 of 190 hf_ha245e2c51g1s1500hx.out 648,761 11-18-2019 18:50 ad7c9570
\\v1.2\\hf\\ha325\\ (22) 7,195,840 11-18-2019 20:33 hf_ha325e2c51g1s0500hx.inp 3,753 11-18-2019 01:27 b6c556e8 hf_ha325e2c51g1s0500hx.out 650,569 11-18-2019 06:46 d474f1d5 hf_ha325e2c51g1s0600hx.inp 3,753 11-18-2019 01:27 9ccded99 hf_ha325e2c51g1s0600hx.out 650,281 11-18-2019 06:47 5db7d33e hf_ha325e2c51g1s0700hx.inp 3,753 11-18-2019 01:27 399b580a hf_ha325e2c51g1s0700hx.out 650,139 11-18-2019 06:58 c6b36c2d hf_ha325e2c51g1s0800hx.inp 3,753 11-18-2019 01:27 6a420bc3 hf_ha325e2c51g1s0800hx.out 650,132 11-18-2019 06:48 26f550c5 hf_ha325e2c51g1s0900hx.inp 3,753 11-18-2019 01:27 d792fbfb hf_ha325e2c51g1s0900hx.out 650,980 11-18-2019 06:52 6f760588 hf_ha325e2c51g1s1000hx.inp 3,757 11-18-2019 01:27 f269a55b hf_ha325e2c51g1s1000hx.out 650,164 11-18-2019 06:48 1b8efacd hf_ha325e2c51g1s1100hx.inp 3,757 11-18-2019 01:27 3d4fe4c8 hf_ha325e2c51g1s1100hx.out 650,726 11-18-2019 07:02 7eccd853 hf_ha325e2c51g1s1200hx.inp 3,757 11-18-2019 01:27 ac17aaa3 hf_ha325e2c51g1s1200hx.out 649,649 11-18-2019 07:04 bf353d3f hf_ha325e2c51g1s1300hx.inp 3,757 11-18-2019 01:27 1f853a4f hf_ha325e2c51g1s1300hx.out 650,771 11-18-2019 07:06 94ce46f7 hf_ha325e2c51g1s1400hx.inp 3,757 11-18-2019 01:27 a7aef124 hf_ha325e2c51g1s1400hx.out 650,225 11-18-2019 06:55 1431e982 hf_ha325e2c51g1s1500hx.inp 3,757 11-18-2019 01:27 8282a530 hf_ha325e2c51g1s1500hx.out 650,897 11-18-2019 06:58 61a7bb1b
\\v1.2\\hf\\na245\\ (22) 5,563,552 11-20-2019 09:22 hf_na245e2c51g1s0500hx.inp 3,576 11-18-2019 12:07 989a0db3 hf_na245e2c51g1s0500hx.out 501,661 11-19-2019 10:13 fc00d269 hf_na245e2c51g1s0600hx.inp 3,577 11-18-2019 12:07 20d4c19a hf_na245e2c51g1s0600hx.out 502,027 11-19-2019 10:15 cd11ca30 hf_na245e2c51g1s0700hx.inp 3,577 11-18-2019 12:07 520db3a9 hf_na245e2c51g1s0700hx.out 502,836 11-19-2019 10:10 0d830e34 hf_na245e2c51g1s0800hx.inp 3,577 11-18-2019 12:07 ccfbce97 hf_na245e2c51g1s0800hx.out 502,174 11-19-2019 10:12 91a68595 hf_na245e2c51g1s0900hx.inp 3,577 11-18-2019 12:07 cb1ce364 hf_na245e2c51g1s0900hx.out 502,146 11-19-2019 10:10 4ec4ed14 hf_na245e2c51g1s1000hx.inp 3,581 11-18-2019 12:07 81186cff hf_na245e2c51g1s1000hx.out 502,245 11-19-2019 10:13 036d2da2 hf_na245e2c51g1s1100hx.inp 3,581 11-18-2019 12:07 1257838a hf_na245e2c51g1s1100hx.out 502,365 11-19-2019 10:12 1bcf7e3a hf_na245e2c51g1s1200hx.inp 3,581 11-18-2019 12:07 fd55828f hf_na245e2c51g1s1200hx.out 502,934 11-19-2019 10:21 ca4e5c5f hf_na245e2c51g1s1300hx.inp 3,581 11-18-2019 12:07 89c758cd hf_na245e2c51g1s1300hx.out 501,491 11-19-2019 10:15 35d256ea hf_na245e2c51g1s1400hx.inp 3,581 11-18-2019 12:07 e6ffab29 hf_na245e2c51g1s1400hx.out 502,336 11-19-2019 10:18 d5c3f56f hf_na245e2c51g1s1500hx.inp 3,581 11-18-2019 12:07 16d64d12 hf_na245e2c51g1s1500hx.out 501,967 11-19-2019 10:17 c2c77809
\\v1.2\\hf\\na325\\ (22) 5,587,750 11-20-2019 09:22 hf_na325e2c51g1s0500hx.inp 3,785 11-18-2019 11:02 4c011fe1 hf_na325e2c51g1s0500hx.out 503,351 11-19-2019 02:28 3c15250a hf_na325e2c51g1s0600hx.inp 3,785 11-18-2019 11:02 957b1d73 hf_na325e2c51g1s0600hx.out 503,726 11-19-2019 02:26 2d770d13 hf_na325e2c51g1s0700hx.inp 3,785 11-18-2019 11:02 e77180b7 hf_na325e2c51g1s0700hx.out 503,923 11-19-2019 02:31 29153461 hf_na325e2c51g1s0800hx.inp 3,785 11-18-2019 11:02 dc25285e hf_na325e2c51g1s0800hx.out 504,310 11-19-2019 02:20 724ad372 hf_na325e2c51g1s0900hx.inp 3,785 11-18-2019 11:02 4511d8be hf_na325e2c51g1s0900hx.out 503,600 11-19-2019 02:32 3108ee75 hf_na325e2c51g1s1000hx.inp 3,789 11-18-2019 11:02 dacfbc1d hf_na325e2c51g1s1000hx.out 504,581 11-19-2019 02:33 588b2dba hf_na325e2c51g1s1100hx.inp 3,789 11-18-2019 11:02 a88430f4 hf_na325e2c51g1s1100hx.out 504,436 11-19-2019 02:49 d668e62a hf_na325e2c51g1s1200hx.inp 3,789 11-18-2019 11:02 e2f229ce hf_na325e2c51g1s1200hx.out 504,071 11-19-2019 02:41 212c1afb hf_na325e2c51g1s1300hx.inp 3,789 11-18-2019 11:02 9f898c24 hf_na325e2c51g1s1300hx.out 504,738 11-19-2019 02:41 3c4672f1 hf_na325e2c51g1s1400hx.inp 3,789 11-18-2019 11:02 2f66d959 hf_na325e2c51g1s1400hx.out 504,738 11-19-2019 02:40 c993b4e3 hf_na325e2c51g1s1500hx.inp 3,789 11-18-2019 11:02 fbb3f868 hf_na325e2c51g1s1500hx.out 504,617 11-19-2019 02:43 533ab026
\\v1.2\\hg\\ (0) 23,517,764 11-18-2019 15:35
\\v1.2\\hg\\ha245\\ (18) 5,869,075 11-22-2019 12:48
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
173 of 190 hg_ha245e2c51g1s001vfio.inp 3,570 11-18-2019 09:57 0c1ed26c hg_ha245e2c51g1s001vfio.out 649,086 11-18-2019 18:40 fafe730a hg_ha245e2c51g1s005vfio.inp 3,570 11-18-2019 09:57 68f7d1cc hg_ha245e2c51g1s005vfio.out 647,638 11-18-2019 17:57 a6b690c4 hg_ha245e2c51g1s010vfio.inp 3,570 11-18-2019 09:57 49b45d62 hg_ha245e2c51g1s010vfio.out 648,415 11-18-2019 17:50 c0e7d0bb hg_ha245e2c51g1s030vfio.inp 3,570 11-18-2019 09:57 33dab551 hg_ha245e2c51g1s030vfio.out 648,694 11-18-2019 18:22 803e3de0 hg_ha245e2c51g1s050vfio.inp 3,570 11-18-2019 09:57 36c59eca hg_ha245e2c51g1s050vfio.out 649,060 11-18-2019 18:23 4e83d6fa hg_ha245e2c51g1s070vfio.inp 3,570 11-18-2019 09:57 a0ec8fc9 hg_ha245e2c51g1s070vfio.out 648,780 11-18-2019 18:41 22823d85 hg_ha245e2c51g1s090vfio.inp 3,570 11-18-2019 09:58 77aaf3a6 hg_ha245e2c51g1s090vfio.out 648,539 11-18-2019 18:46 03935146 hg_ha245e2c51g1s095vfio.inp 3,570 11-18-2019 09:58 5d8b9a66 hg_ha245e2c51g1s095vfio.out 648,245 11-18-2019 18:36 b35d19ef hg_ha245e2c51g1s100vfio.inp 3,570 11-18-2019 09:58 b74b0de0 hg_ha245e2c51g1s100vfio.out 648,488 11-18-2019 18:53 437636a1
\\v1.2\\hg\\ha325\\ (18) 5,888,261 11-22-2019 12:48 hg_ha325e2c51g1s001vfio.inp 3,746 11-18-2019 01:28 0d90a5c5 hg_ha325e2c51g1s001vfio.out 650,264 11-18-2019 07:04 39ac316d hg_ha325e2c51g1s005vfio.inp 3,746 11-18-2019 01:28 2ab6170d hg_ha325e2c51g1s005vfio.out 650,365 11-18-2019 06:15 6bc4f4fb hg_ha325e2c51g1s010vfio.inp 3,746 11-18-2019 01:28 72885189 hg_ha325e2c51g1s010vfio.out 650,285 11-18-2019 06:08 52000599 hg_ha325e2c51g1s030vfio.inp 3,746 11-18-2019 01:28 72ff84af hg_ha325e2c51g1s030vfio.out 651,164 11-18-2019 06:48 bf8bf530 hg_ha325e2c51g1s050vfio.inp 3,746 11-18-2019 01:28 a10ce30d hg_ha325e2c51g1s050vfio.out 650,792 11-18-2019 07:03 1f965844 hg_ha325e2c51g1s070vfio.inp 3,746 11-18-2019 01:28 e66c9c11 hg_ha325e2c51g1s070vfio.out 650,654 11-18-2019 07:15 e35fb0d3 hg_ha325e2c51g1s090vfio.inp 3,746 11-18-2019 01:28 e3f3d16a hg_ha325e2c51g1s090vfio.out 650,290 11-18-2019 07:13 3013e26c hg_ha325e2c51g1s095vfio.inp 3,746 11-18-2019 01:28 39a77056 hg_ha325e2c51g1s095vfio.out 650,601 11-18-2019 07:21 db68b7b6 hg_ha325e2c51g1s100vfio.inp 3,746 11-18-2019 01:28 0452581b hg_ha325e2c51g1s100vfio.out 650,132 11-18-2019 07:19 c88a740e
\\v1.2\\hg\\na245\\ (18) 5,869,968 11-22-2019 12:48 hg_na245e2c51g1s001vfio.inp 3,570 11-18-2019 12:08 4645b674 hg_na245e2c51g1s001vfio.out 649,629 11-19-2019 10:38 d9fbed4e hg_na245e2c51g1s005vfio.inp 3,570 11-18-2019 12:08 22acb5d4 hg_na245e2c51g1s005vfio.out 649,109 11-19-2019 09:20 934b061b hg_na245e2c51g1s010vfio.inp 3,570 11-18-2019 12:08 03ef397a hg_na245e2c51g1s010vfio.out 647,905 11-19-2019 09:20 dc49cb67 hg_na245e2c51g1s030vfio.inp 3,570 11-18-2019 12:08 7981d149 hg_na245e2c51g1s030vfio.out 648,961 11-19-2019 09:49 974e7dd9 hg_na245e2c51g1s050vfio.inp 3,570 11-18-2019 12:08 7c9efad2 hg_na245e2c51g1s050vfio.out 648,573 11-19-2019 10:02 c2d06e51 hg_na245e2c51g1s070vfio.inp 3,570 11-18-2019 12:08 eab7ebd1 hg_na245e2c51g1s070vfio.out 648,966 11-19-2019 10:09 52387eaa hg_na245e2c51g1s090vfio.inp 3,570 11-18-2019 12:08 3df197be hg_na245e2c51g1s090vfio.out 648,603 11-19-2019 10:17 f929b2ea hg_na245e2c51g1s095vfio.inp 3,570 11-18-2019 12:08 17d0fe7e hg_na245e2c51g1s095vfio.out 647,632 11-19-2019 10:15 c5a15c41 hg_na245e2c51g1s100vfio.inp 3,570 11-18-2019 12:08 fd1069f8 hg_na245e2c51g1s100vfio.out 648,460 11-19-2019 10:19 ff8981b0
\\v1.2\\hg\\na325\\ (18) 5,890,460 11-22-2019 12:48 hg_na325e2c51g1s001vfio.inp 3,778 11-18-2019 11:03 fbfa36f9 hg_na325e2c51g1s001vfio.out 650,907 11-19-2019 02:56 7af29d21 hg_na325e2c51g1s005vfio.inp 3,778 11-18-2019 11:03 a59e81c0 hg_na325e2c51g1s005vfio.out 650,783 11-19-2019 01:55 108a7478 hg_na325e2c51g1s010vfio.inp 3,778 11-18-2019 11:03 e858c842 hg_na325e2c51g1s010vfio.out 650,390 11-19-2019 01:50 5e88a840 hg_na325e2c51g1s030vfio.inp 3,778 11-18-2019 11:03 01b62e5a hg_na325e2c51g1s030vfio.out 651,203 11-19-2019 02:24 ec58cab4 hg_na325e2c51g1s050vfio.inp 3,778 11-18-2019 11:03 a46d94d1 hg_na325e2c51g1s050vfio.out 650,442 11-19-2019 02:39 aaee827f hg_na325e2c51g1s070vfio.inp 3,778 11-18-2019 11:03 e06fe1b4 hg_na325e2c51g1s070vfio.out 650,494 11-19-2019 02:59 6f6cc287 hg_na325e2c51g1s090vfio.inp 3,778 11-18-2019 11:03 41cc6ac2 hg_na325e2c51g1s090vfio.out 650,472 11-19-2019 02:44 5471f716 hg_na325e2c51g1s095vfio.inp 3,778 11-18-2019 11:03 adea9555 hg_na325e2c51g1s095vfio.out 651,561 11-19-2019 03:06 3c2d3253 hg_na325e2c51g1s100vfio.inp 3,778 11-18-2019 11:03 138573d1
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
174 of 190 hg_na325e2c51g1s100vfio.out 650,206 11-19-2019 03:14 2a7e2649
\\v1.2\\hh\\ (0) 20,884,440 11-18-2019 15:35
\\v1.2\\hh\\ha245\\ (18) 5,869,032 11-22-2019 12:48 hh_ha245e2c51g1s001vfio.inp 3,577 11-18-2019 09:58 cfa25cff hh_ha245e2c51g1s001vfio.out 648,830 11-18-2019 18:43 e928075a hh_ha245e2c51g1s005vfio.inp 3,577 11-18-2019 09:58 f8682c05 hh_ha245e2c51g1s005vfio.out 649,165 11-18-2019 17:56 1bbe36a8 hh_ha245e2c51g1s010vfio.inp 3,577 11-18-2019 09:58 b0e8ccfe hh_ha245e2c51g1s010vfio.out 648,181 11-18-2019 17:51 7d97ea8f hh_ha245e2c51g1s030vfio.inp 3,577 11-18-2019 09:58 56dc6f43 hh_ha245e2c51g1s030vfio.out 648,757 11-18-2019 18:23 2667f0df hh_ha245e2c51g1s050vfio.inp 3,577 11-18-2019 09:58 96c74a74 hh_ha245e2c51g1s050vfio.out 647,806 11-18-2019 18:52 4c8cd5ca hh_ha245e2c51g1s070vfio.inp 3,577 11-18-2019 09:58 f2a5f9f4 hh_ha245e2c51g1s070vfio.out 648,428 11-18-2019 18:46 50239b18 hh_ha245e2c51g1s090vfio.inp 3,577 11-18-2019 09:58 0e4c38fe hh_ha245e2c51g1s090vfio.out 648,778 11-18-2019 18:59 40ff814f hh_ha245e2c51g1s095vfio.inp 3,577 11-18-2019 09:58 81d3dc40 hh_ha245e2c51g1s095vfio.out 648,629 11-18-2019 18:58 22a2786e hh_ha245e2c51g1s100vfio.inp 3,577 11-18-2019 09:59 1abd507d hh_ha245e2c51g1s100vfio.out 648,265 11-18-2019 18:55 2f22feaa
\\v1.2\\hh\\ha325\\ (18) 5,888,833 11-22-2019 12:48 hh_ha325e2c51g1s001vfio.inp 3,753 11-18-2019 01:28 c1154e02 hh_ha325e2c51g1s001vfio.out 649,636 11-18-2019 07:07 75a05f03 hh_ha325e2c51g1s005vfio.inp 3,753 11-18-2019 01:29 46a05539 hh_ha325e2c51g1s005vfio.out 651,326 11-18-2019 06:14 cbf48464 hh_ha325e2c51g1s010vfio.inp 3,753 11-18-2019 01:29 fbf8e7e1 hh_ha325e2c51g1s010vfio.out 651,138 11-18-2019 06:07 e1d285c5 hh_ha325e2c51g1s030vfio.inp 3,753 11-18-2019 01:29 f30645cb hh_ha325e2c51g1s030vfio.out 649,489 11-18-2019 06:51 47540148 hh_ha325e2c51g1s050vfio.inp 3,753 11-18-2019 01:29 1c33ca82 hh_ha325e2c51g1s050vfio.out 650,658 11-18-2019 06:58 1b4f9d19 hh_ha325e2c51g1s070vfio.inp 3,753 11-18-2019 01:29 9bd629d3 hh_ha325e2c51g1s070vfio.out 650,854 11-18-2019 07:09 b6b24c1a hh_ha325e2c51g1s090vfio.inp 3,753 11-18-2019 01:29 b31db5b1 hh_ha325e2c51g1s090vfio.out 650,666 11-18-2019 07:15 5b777e36 hh_ha325e2c51g1s095vfio.inp 3,753 11-18-2019 01:29 51646dab hh_ha325e2c51g1s095vfio.out 650,307 11-18-2019 07:34 4e7a5fa1 hh_ha325e2c51g1s100vfio.inp 3,753 11-18-2019 01:29 d792fbfb hh_ha325e2c51g1s100vfio.out 650,982 11-18-2019 07:26 70b23013
\\v1.2\\hh\\na245\\ (18) 4,553,757 11-22-2019 12:48 hh_na245e2c51g1s001vfio.inp 3,577 11-18-2019 12:08 1e03efe6 hh_na245e2c51g1s001vfio.out 502,746 11-19-2019 10:29 e7d63af8 hh_na245e2c51g1s005vfio.inp 3,577 11-18-2019 12:09 29c99f1c hh_na245e2c51g1s005vfio.out 503,031 11-19-2019 09:33 ea1fe54f hh_na245e2c51g1s010vfio.inp 3,577 11-18-2019 12:09 61497fe7 hh_na245e2c51g1s010vfio.out 502,425 11-19-2019 09:23 abba8bf4 hh_na245e2c51g1s030vfio.inp 3,577 11-18-2019 12:09 877ddc5a hh_na245e2c51g1s030vfio.out 502,082 11-19-2019 10:02 9aaeeb0f hh_na245e2c51g1s050vfio.inp 3,577 11-18-2019 12:09 4766f96d hh_na245e2c51g1s050vfio.out 502,347 11-19-2019 10:13 ae81a1e2 hh_na245e2c51g1s070vfio.inp 3,577 11-18-2019 12:09 23044aed hh_na245e2c51g1s070vfio.out 502,034 11-19-2019 10:20 6ee5c3e7 hh_na245e2c51g1s090vfio.inp 3,577 11-18-2019 12:09 dfed8be7 hh_na245e2c51g1s090vfio.out 501,872 11-19-2019 10:26 e2cecc4c hh_na245e2c51g1s095vfio.inp 3,577 11-18-2019 12:09 50726f59 hh_na245e2c51g1s095vfio.out 502,882 11-19-2019 10:24 957a822f hh_na245e2c51g1s100vfio.inp 3,577 11-18-2019 12:09 cb1ce364 hh_na245e2c51g1s100vfio.out 502,145 11-19-2019 10:18 db3d45c7
\\v1.2\\hh\\na325\\ (18) 4,572,818 11-22-2019 12:48 hh_na325e2c51g1s001vfio.inp 3,785 11-18-2019 11:03 24351944 hh_na325e2c51g1s001vfio.out 503,951 11-19-2019 03:00 04afcf95 hh_na325e2c51g1s005vfio.inp 3,785 11-18-2019 11:03 0540469e hh_na325e2c51g1s005vfio.out 504,236 11-19-2019 02:04 e0a85c51 hh_na325e2c51g1s010vfio.inp 3,785 11-18-2019 11:04 351dcf98 hh_na325e2c51g1s010vfio.out 504,481 11-19-2019 01:57 63aeac49 hh_na325e2c51g1s030vfio.inp 3,785 11-18-2019 11:04 30308d6d hh_na325e2c51g1s030vfio.out 504,341 11-19-2019 02:34 fef164a6 hh_na325e2c51g1s050vfio.inp 3,785 11-18-2019 11:04 9465ea1f hh_na325e2c51g1s050vfio.out 504,995 11-19-2019 02:25 cc9b9171 hh_na325e2c51g1s070vfio.inp 3,785 11-18-2019 11:04 3aac3413
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
175 of 190 hh_na325e2c51g1s070vfio.out 504,090 11-19-2019 02:33 e07bac50 hh_na325e2c51g1s090vfio.inp 3,785 11-18-2019 11:04 12d9efcd hh_na325e2c51g1s090vfio.out 504,507 11-19-2019 03:06 f3efcebf hh_na325e2c51g1s095vfio.inp 3,785 11-18-2019 11:04 d5dacd16 hh_na325e2c51g1s095vfio.out 504,552 11-19-2019 03:16 511e1312 hh_na325e2c51g1s100vfio.inp 3,785 11-18-2019 11:04 4511d8be hh_na325e2c51g1s100vfio.out 503,600 11-19-2019 02:54 1ac6254f
\\v1.2\\hi\\ (0) 28,600,092 11-18-2019 15:35
\\v1.2\\hi\\ha245\\ (22) 7,175,146 11-18-2019 20:33 hi_ha245e2c51g1s0500hx.inp 3,605 11-18-2019 09:48 87116ead hi_ha245e2c51g1s0500hx.out 649,159 11-18-2019 18:55 2e78a81b hi_ha245e2c51g1s0600hx.inp 3,606 11-18-2019 09:48 7e917259 hi_ha245e2c51g1s0600hx.out 647,786 11-18-2019 18:42 b7d37e92 hi_ha245e2c51g1s0700hx.inp 3,606 11-18-2019 09:48 b8096f36 hi_ha245e2c51g1s0700hx.out 648,816 11-18-2019 18:48 eb4a09d2 hi_ha245e2c51g1s0800hx.inp 3,606 11-18-2019 09:48 d449ef8c hi_ha245e2c51g1s0800hx.out 648,947 11-18-2019 18:51 aa449f2b hi_ha245e2c51g1s0900hx.inp 3,606 11-18-2019 09:48 14f5ffbb hi_ha245e2c51g1s0900hx.out 649,599 11-18-2019 18:50 55f4593d hi_ha245e2c51g1s1000hx.inp 3,610 11-18-2019 09:48 5162a7dd hi_ha245e2c51g1s1000hx.out 647,970 11-18-2019 18:55 1d637dfc hi_ha245e2c51g1s1100hx.inp 3,610 11-18-2019 09:48 8d9ac837 hi_ha245e2c51g1s1100hx.out 647,622 11-18-2019 18:52 903027f5 hi_ha245e2c51g1s1200hx.inp 3,610 11-18-2019 09:48 5e2f92c3 hi_ha245e2c51g1s1200hx.out 648,833 11-18-2019 18:57 e6facef1 hi_ha245e2c51g1s1300hx.inp 3,610 11-18-2019 09:49 bef92ccd hi_ha245e2c51g1s1300hx.out 649,619 11-18-2019 18:57 8f1d7f83 hi_ha245e2c51g1s1400hx.inp 3,610 11-18-2019 09:49 032233af hi_ha245e2c51g1s1400hx.out 648,158 11-18-2019 18:58 182b6b5a hi_ha245e2c51g1s1500hx.inp 3,610 11-18-2019 09:49 015ddb51 hi_ha245e2c51g1s1500hx.out 648,948 11-18-2019 19:00 0f1ae3f8
\\v1.2\\hi\\ha325\\ (22) 7,197,019 11-18-2019 20:33 hi_ha325e2c51g1s0500hx.inp 3,793 11-18-2019 01:39 e781757f hi_ha325e2c51g1s0500hx.out 650,146 11-18-2019 08:20 1a341aba hi_ha325e2c51g1s0600hx.inp 3,793 11-18-2019 01:40 5b7cff99 hi_ha325e2c51g1s0600hx.out 650,984 11-18-2019 08:12 27c5192d hi_ha325e2c51g1s0700hx.inp 3,793 11-18-2019 01:40 dba3953d hi_ha325e2c51g1s0700hx.out 649,944 11-18-2019 08:07 745490b2 hi_ha325e2c51g1s0800hx.inp 3,793 11-18-2019 01:40 03bd9317 hi_ha325e2c51g1s0800hx.out 650,556 11-18-2019 09:14 0d319081 hi_ha325e2c51g1s0900hx.inp 3,793 11-18-2019 01:40 4e26c379 hi_ha325e2c51g1s0900hx.out 649,943 11-18-2019 09:17 723754c1 hi_ha325e2c51g1s1000hx.inp 3,797 11-18-2019 01:40 f7c546da hi_ha325e2c51g1s1000hx.out 650,534 11-18-2019 09:16 6ff93a75 hi_ha325e2c51g1s1100hx.inp 3,797 11-18-2019 01:40 4355842a hi_ha325e2c51g1s1100hx.out 650,806 11-18-2019 08:17 f78f9cc9 hi_ha325e2c51g1s1200hx.inp 3,797 11-18-2019 01:40 f8c2afe1 hi_ha325e2c51g1s1200hx.out 650,366 11-18-2019 08:21 09b1b22b hi_ha325e2c51g1s1300hx.inp 3,797 11-18-2019 01:40 33eff00d hi_ha325e2c51g1s1300hx.out 650,756 11-18-2019 08:38 fe09bab7 hi_ha325e2c51g1s1400hx.inp 3,797 11-18-2019 01:40 a85a4934 hi_ha325e2c51g1s1400hx.out 651,054 11-18-2019 08:08 857fee5a hi_ha325e2c51g1s1500hx.inp 3,797 11-18-2019 01:40 fffac947 hi_ha325e2c51g1s1500hx.out 650,183 11-18-2019 09:22 82b56347
\\v1.2\\hi\\na245\\ (22) 7,029,448 11-20-2019 09:22 hi_na245e2c51g1s0500hx.inp 3,605 11-18-2019 11:58 060c6ea3 hi_na245e2c51g1s0500hx.out 501,850 11-19-2019 10:28 799dc023 hi_na245e2c51g1s0600hx.inp 3,606 11-18-2019 11:58 683d89a4 hi_na245e2c51g1s0600hx.out 648,865 11-19-2019 10:28 284de1da hi_na245e2c51g1s0700hx.inp 3,606 11-18-2019 11:58 aea594cb hi_na245e2c51g1s0700hx.out 648,854 11-19-2019 10:29 c3ba5a8d hi_na245e2c51g1s0800hx.inp 3,606 11-18-2019 11:58 c2e51471 hi_na245e2c51g1s0800hx.out 647,570 11-19-2019 10:36 8c2703de hi_na245e2c51g1s0900hx.inp 3,606 11-18-2019 11:58 02590446 hi_na245e2c51g1s0900hx.out 649,385 11-19-2019 10:31 b1950de1 hi_na245e2c51g1s1000hx.inp 3,610 11-18-2019 11:58 ccb9049b hi_na245e2c51g1s1000hx.out 649,276 11-19-2019 10:31 d304368d hi_na245e2c51g1s1100hx.inp 3,610 11-18-2019 11:58 10416b71 hi_na245e2c51g1s1100hx.out 648,534 11-19-2019 10:35 fd6ae7c0 hi_na245e2c51g1s1200hx.inp 3,610 11-18-2019 11:58 c3f43185 hi_na245e2c51g1s1200hx.out 648,779 11-19-2019 10:34 27198d9f hi_na245e2c51g1s1300hx.inp 3,610 11-18-2019 11:58 23228f8b hi_na245e2c51g1s1300hx.out 648,288 11-19-2019 10:35 d1c72775
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
176 of 190 hi_na245e2c51g1s1400hx.inp 3,610 11-18-2019 11:59 9ef990e9 hi_na245e2c51g1s1400hx.out 649,524 11-19-2019 10:35 c164e8e7 hi_na245e2c51g1s1500hx.inp 3,610 11-18-2019 11:59 9c867817 hi_na245e2c51g1s1500hx.out 648,834 11-19-2019 10:39 430a3439
\\v1.2\\hi\\na325\\ (22) 7,198,479 11-20-2019 09:22 hi_na325e2c51g1s0500hx.inp 3,825 11-18-2019 10:53 3852436d hi_na325e2c51g1s0500hx.out 650,903 11-19-2019 02:59 158c6554 hi_na325e2c51g1s0600hx.inp 3,825 11-18-2019 10:53 d7b17668 hi_na325e2c51g1s0600hx.out 650,899 11-19-2019 02:53 caeec19e hi_na325e2c51g1s0700hx.inp 3,825 11-18-2019 10:53 f9411246 hi_na325e2c51g1s0700hx.out 649,368 11-19-2019 02:51 87290698 hi_na325e2c51g1s0800hx.inp 3,825 11-18-2019 10:53 bc0f1e68 hi_na325e2c51g1s0800hx.out 650,550 11-19-2019 02:53 71764dbf hi_na325e2c51g1s0900hx.inp 3,825 11-18-2019 10:53 7c1d1bc0 hi_na325e2c51g1s0900hx.out 649,782 11-19-2019 02:52 9f606968 hi_na325e2c51g1s1000hx.inp 3,829 11-18-2019 10:54 f0edefa9 hi_na325e2c51g1s1000hx.out 651,097 11-19-2019 02:53 29a864af hi_na325e2c51g1s1100hx.inp 3,829 11-18-2019 10:54 95b3cbc8 hi_na325e2c51g1s1100hx.out 650,577 11-19-2019 02:50 5dea099f hi_na325e2c51g1s1200hx.inp 3,829 11-18-2019 10:54 b6874b94 hi_na325e2c51g1s1200hx.out 651,664 11-19-2019 02:45 0b87b371 hi_na325e2c51g1s1300hx.inp 3,829 11-18-2019 10:54 397b8e1e hi_na325e2c51g1s1300hx.out 651,132 11-19-2019 02:57 f4059e60 hi_na325e2c51g1s1400hx.inp 3,829 11-18-2019 10:54 796b959e hi_na325e2c51g1s1400hx.out 650,813 11-19-2019 03:04 32736462 hi_na325e2c51g1s1500hx.inp 3,829 11-18-2019 10:54 47a150ed hi_na325e2c51g1s1500hx.out 649,595 11-19-2019 03:14 6dd13428
\\v1.2\\hj\\ (0) 25,526,005 11-18-2019 15:35
\\v1.2\\hj\\ha245\\ (22) 7,171,910 11-18-2019 20:33 hj_ha245e2c51g1s0500hx.inp 3,612 11-18-2019 09:49 a3878fa7 hj_ha245e2c51g1s0500hx.out 647,480 11-18-2019 19:03 42b1e611 hj_ha245e2c51g1s0600hx.inp 3,613 11-18-2019 09:49 0b5d6887 hj_ha245e2c51g1s0600hx.out 648,220 11-18-2019 18:51 bf151d0a hj_ha245e2c51g1s0700hx.inp 3,613 11-18-2019 09:49 9c5dc458 hj_ha245e2c51g1s0700hx.out 648,372 11-18-2019 19:02 44a11b76 hj_ha245e2c51g1s0800hx.inp 3,613 11-18-2019 09:49 1bdb40e3 hj_ha245e2c51g1s0800hx.out 648,199 11-18-2019 18:55 65e26cd2 hj_ha245e2c51g1s0900hx.inp 3,613 11-18-2019 09:49 1cf9fc94 hj_ha245e2c51g1s0900hx.out 648,209 11-18-2019 18:52 5aae4d6b hj_ha245e2c51g1s1000hx.inp 3,617 11-18-2019 09:49 39682813 hj_ha245e2c51g1s1000hx.out 648,833 11-18-2019 18:55 08eb7d24 hj_ha245e2c51g1s1100hx.inp 3,617 11-18-2019 09:49 f5956c7d hj_ha245e2c51g1s1100hx.out 648,867 11-18-2019 18:59 f1f22fd2 hj_ha245e2c51g1s1200hx.inp 3,617 11-18-2019 09:49 e7ede55a hj_ha245e2c51g1s1200hx.out 649,013 11-18-2019 19:02 bdf180f4 hj_ha245e2c51g1s1300hx.inp 3,617 11-18-2019 09:49 2bef05d4 hj_ha245e2c51g1s1300hx.out 647,483 11-18-2019 18:56 aa4b56e3 hj_ha245e2c51g1s1400hx.inp 3,617 11-18-2019 09:50 f02ea5e6 hj_ha245e2c51g1s1400hx.out 648,808 11-18-2019 19:08 b8390e32 hj_ha245e2c51g1s1500hx.inp 3,617 11-18-2019 09:50 07b85968 hj_ha245e2c51g1s1500hx.out 648,660 11-18-2019 19:08 2ee44610
\\v1.2\\hj\\ha325\\ (22) 7,197,780 11-18-2019 20:33 hj_ha325e2c51g1s0500hx.inp 3,800 11-18-2019 01:40 67c0fb30 hj_ha325e2c51g1s0500hx.out 650,288 11-18-2019 08:22 2d882e3a hj_ha325e2c51g1s0600hx.inp 3,800 11-18-2019 01:40 a4cda3c5 hj_ha325e2c51g1s0600hx.out 650,697 11-18-2019 08:57 7c156cad hj_ha325e2c51g1s0700hx.inp 3,800 11-18-2019 01:41 9747f90b hj_ha325e2c51g1s0700hx.out 650,646 11-18-2019 08:22 15526aca hj_ha325e2c51g1s0800hx.inp 3,800 11-18-2019 01:41 dc6370a7 hj_ha325e2c51g1s0800hx.out 650,462 11-18-2019 08:10 7b629d3f hj_ha325e2c51g1s0900hx.inp 3,800 11-18-2019 01:41 5eecfcdc hj_ha325e2c51g1s0900hx.out 650,959 11-18-2019 08:56 99842c62 hj_ha325e2c51g1s1000hx.inp 3,804 11-18-2019 01:41 a4279a7e hj_ha325e2c51g1s1000hx.out 651,249 11-18-2019 09:18 62590dfe hj_ha325e2c51g1s1100hx.inp 3,804 11-18-2019 01:41 534e9fe2 hj_ha325e2c51g1s1100hx.out 650,750 11-18-2019 08:06 3824bbd4 hj_ha325e2c51g1s1200hx.inp 3,804 11-18-2019 01:41 94bdfb48 hj_ha325e2c51g1s1200hx.out 650,651 11-18-2019 09:21 36c01586 hj_ha325e2c51g1s1300hx.inp 3,804 11-18-2019 01:41 0eac3354 hj_ha325e2c51g1s1300hx.out 649,749 11-18-2019 08:14 d2c92418 hj_ha325e2c51g1s1400hx.inp 3,804 11-18-2019 01:41 1455d89c hj_ha325e2c51g1s1400hx.out 650,091 11-18-2019 09:25 15a2ec03 hj_ha325e2c51g1s1500hx.inp 3,804 11-18-2019 01:41 9b351816
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
177 of 190 hj_ha325e2c51g1s1500hx.out 650,414 11-18-2019 09:24 7e8a8566
\\v1.2\\hj\\na245\\ (22) 5,564,027 11-20-2019 09:22 hj_na245e2c51g1s0500hx.inp 3,612 11-18-2019 11:59 93b21ce8 hj_na245e2c51g1s0500hx.out 502,431 11-19-2019 10:32 8821c0b5 hj_na245e2c51g1s0600hx.inp 3,613 11-18-2019 11:59 1c9bcaef hj_na245e2c51g1s0600hx.out 501,992 11-19-2019 10:32 b04e1702 hj_na245e2c51g1s0700hx.inp 3,613 11-18-2019 11:59 8b9b6630 hj_na245e2c51g1s0700hx.out 502,649 11-19-2019 10:37 02f2a0ea hj_na245e2c51g1s0800hx.inp 3,613 11-18-2019 11:59 0c1de28b hj_na245e2c51g1s0800hx.out 501,423 11-19-2019 10:41 6f99cdef hj_na245e2c51g1s0900hx.inp 3,613 11-18-2019 11:59 0b3f5efc hj_na245e2c51g1s0900hx.out 501,971 11-19-2019 10:38 bb1daae7 hj_na245e2c51g1s1000hx.inp 3,617 11-18-2019 11:59 9dab165e hj_na245e2c51g1s1000hx.out 502,509 11-19-2019 10:36 758c9d64 hj_na245e2c51g1s1100hx.inp 3,617 11-18-2019 11:59 51565230 hj_na245e2c51g1s1100hx.out 503,107 11-19-2019 10:28 aa7ca822 hj_na245e2c51g1s1200hx.inp 3,617 11-18-2019 11:59 432edb17 hj_na245e2c51g1s1200hx.out 502,196 11-19-2019 10:41 c1400d50 hj_na245e2c51g1s1300hx.inp 3,617 11-18-2019 11:59 8f2c3b99 hj_na245e2c51g1s1300hx.out 501,961 11-19-2019 10:44 75e4d057 hj_na245e2c51g1s1400hx.inp 3,617 11-18-2019 12:00 54ed9bab hj_na245e2c51g1s1400hx.out 502,242 11-19-2019 10:56 fad386f3 hj_na245e2c51g1s1500hx.inp 3,617 11-18-2019 12:00 a37b6725 hj_na245e2c51g1s1500hx.out 501,780 11-19-2019 10:48 cc8b5fd4
\\v1.2\\hj\\na325\\ (22) 5,592,288 11-20-2019 09:22 hj_na325e2c51g1s0500hx.inp 3,832 11-18-2019 10:54 75a53b6d hj_na325e2c51g1s0500hx.out 504,548 11-19-2019 03:03 241d2571 hj_na325e2c51g1s0600hx.inp 3,832 11-18-2019 10:54 6914f71d hj_na325e2c51g1s0600hx.out 504,577 11-19-2019 03:09 1e9e5286 hj_na325e2c51g1s0700hx.inp 3,832 11-18-2019 10:54 a2d7affc hj_na325e2c51g1s0700hx.out 504,116 11-19-2019 02:57 9a123da9 hj_na325e2c51g1s0800hx.inp 3,832 11-18-2019 10:54 cb1ed797 hj_na325e2c51g1s0800hx.out 503,475 11-19-2019 03:02 c5f7cdbe hj_na325e2c51g1s0900hx.inp 3,832 11-18-2019 10:54 19dad41c hj_na325e2c51g1s0900hx.out 504,154 11-19-2019 03:11 18369b10 hj_na325e2c51g1s1000hx.inp 3,836 11-18-2019 10:55 1f6d1163 hj_na325e2c51g1s1000hx.out 504,600 11-19-2019 03:12 91cb49fd hj_na325e2c51g1s1100hx.inp 3,836 11-18-2019 10:55 a96b19ae hj_na325e2c51g1s1100hx.out 504,701 11-19-2019 03:13 cd56879e hj_na325e2c51g1s1200hx.inp 3,836 11-18-2019 10:55 785ff896 hj_na325e2c51g1s1200hx.out 504,826 11-19-2019 03:02 fbe8948b hj_na325e2c51g1s1300hx.inp 3,836 11-18-2019 10:55 1636e5f3 hj_na325e2c51g1s1300hx.out 505,560 11-19-2019 03:08 899abcba hj_na325e2c51g1s1400hx.inp 3,836 11-18-2019 10:55 a4649ad3 hj_na325e2c51g1s1400hx.out 504,892 11-19-2019 03:12 70913ec0 hj_na325e2c51g1s1500hx.inp 3,836 11-18-2019 10:55 e13d16e3 hj_na325e2c51g1s1500hx.out 504,663 11-19-2019 03:13 e96a3440
\\v1.2\\hk\\ (0) 23,518,686 11-18-2019 15:36
\\v1.2\\hk\\ha245\\ (18) 5,873,206 11-22-2019 12:48 hk_ha245e2c51g1s001vfio.inp 3,606 11-18-2019 09:50 fb96176f hk_ha245e2c51g1s001vfio.out 649,259 11-18-2019 18:09 fca47eb9 hk_ha245e2c51g1s005vfio.inp 3,606 11-18-2019 09:50 afa09f34 hk_ha245e2c51g1s005vfio.out 648,675 11-18-2019 17:37 eb847ab0 hk_ha245e2c51g1s010vfio.inp 3,606 11-18-2019 09:50 1db61757 hk_ha245e2c51g1s010vfio.out 648,209 11-18-2019 17:49 baf8443a hk_ha245e2c51g1s030vfio.inp 3,606 11-18-2019 09:50 7af0a96f hk_ha245e2c51g1s030vfio.out 649,233 11-18-2019 18:23 186f4a28 hk_ha245e2c51g1s050vfio.inp 3,606 11-18-2019 09:50 466e4867 hk_ha245e2c51g1s050vfio.out 649,251 11-18-2019 18:39 efb965fc hk_ha245e2c51g1s070vfio.inp 3,606 11-18-2019 09:50 738b4dd9 hk_ha245e2c51g1s070vfio.out 649,279 11-18-2019 18:54 083ba812 hk_ha245e2c51g1s090vfio.inp 3,606 11-18-2019 09:50 4a41e462 hk_ha245e2c51g1s090vfio.out 648,481 11-18-2019 18:56 590d4dce hk_ha245e2c51g1s095vfio.inp 3,606 11-18-2019 09:50 828a8a2d hk_ha245e2c51g1s095vfio.out 648,764 11-18-2019 18:53 f2c7ef1d hk_ha245e2c51g1s100vfio.inp 3,606 11-18-2019 09:50 14f5ffbb hk_ha245e2c51g1s100vfio.out 649,601 11-18-2019 18:56 9ca9e437
\\v1.2\\hk\\ha325\\ (18) 5,887,258 11-22-2019 12:48 hk_ha325e2c51g1s001vfio.inp 3,793 11-18-2019 01:41 2195bda8 hk_ha325e2c51g1s001vfio.out 650,606 11-18-2019 07:46 bd78097b hk_ha325e2c51g1s005vfio.inp 3,793 11-18-2019 01:41 e6b014ec
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
178 of 190 hk_ha325e2c51g1s005vfio.out 650,944 11-18-2019 08:07 fbb35daa hk_ha325e2c51g1s010vfio.inp 3,793 11-18-2019 01:41 604a94a5 hk_ha325e2c51g1s010vfio.out 649,526 11-18-2019 08:18 9e64ccf5 hk_ha325e2c51g1s030vfio.inp 3,793 11-18-2019 01:42 c547bd50 hk_ha325e2c51g1s030vfio.out 650,682 11-18-2019 08:41 58424e92 hk_ha325e2c51g1s050vfio.inp 3,793 11-18-2019 01:42 a9a3592c hk_ha325e2c51g1s050vfio.out 650,360 11-18-2019 08:50 bd1e514c hk_ha325e2c51g1s070vfio.inp 3,793 11-18-2019 01:42 758d0c33 hk_ha325e2c51g1s070vfio.out 650,370 11-18-2019 09:14 87664629 hk_ha325e2c51g1s090vfio.inp 3,793 11-18-2019 01:42 f9ef813a hk_ha325e2c51g1s090vfio.out 650,215 11-18-2019 09:44 7278e163 hk_ha325e2c51g1s095vfio.inp 3,793 11-18-2019 01:42 699165c9 hk_ha325e2c51g1s095vfio.out 650,472 11-18-2019 09:34 ada2b7a2 hk_ha325e2c51g1s100vfio.inp 3,793 11-18-2019 01:42 4e26c379 hk_ha325e2c51g1s100vfio.out 649,946 11-18-2019 09:21 70c079da
\\v1.2\\hk\\na245\\ (18) 5,870,440 11-22-2019 12:48 hk_na245e2c51g1s001vfio.inp 3,606 11-18-2019 12:00 ed3aec92 hk_na245e2c51g1s001vfio.out 647,642 11-19-2019 09:56 d546dd3d hk_na245e2c51g1s005vfio.inp 3,606 11-18-2019 12:00 b90c64c9 hk_na245e2c51g1s005vfio.out 647,971 11-19-2019 09:28 344b6e65 hk_na245e2c51g1s010vfio.inp 3,606 11-18-2019 12:00 0b1aecaa hk_na245e2c51g1s010vfio.out 648,502 11-19-2019 09:34 afc39674 hk_na245e2c51g1s030vfio.inp 3,606 11-18-2019 12:00 6c5c5292 hk_na245e2c51g1s030vfio.out 649,379 11-19-2019 10:19 b78fb441 hk_na245e2c51g1s050vfio.inp 3,606 11-18-2019 12:00 50c2b39a hk_na245e2c51g1s050vfio.out 647,790 11-19-2019 10:28 785d53ed hk_na245e2c51g1s070vfio.inp 3,606 11-18-2019 12:00 6527b624 hk_na245e2c51g1s070vfio.out 649,063 11-19-2019 10:36 1cee3389 hk_na245e2c51g1s090vfio.inp 3,606 11-18-2019 12:00 5ced1f9f hk_na245e2c51g1s090vfio.out 649,316 11-19-2019 10:47 0f63019c hk_na245e2c51g1s095vfio.inp 3,606 11-18-2019 12:00 942671d0 hk_na245e2c51g1s095vfio.out 648,936 11-19-2019 10:44 2396bccc hk_na245e2c51g1s100vfio.inp 3,606 11-18-2019 12:01 02590446 hk_na245e2c51g1s100vfio.out 649,387 11-19-2019 10:45 958d97ed
\\v1.2\\hk\\na325\\ (18) 5,887,782 11-22-2019 12:48 hk_na325e2c51g1s001vfio.inp 3,825 11-18-2019 10:55 ecc74432 hk_na325e2c51g1s001vfio.out 650,313 11-19-2019 02:27 ee8ece7b hk_na325e2c51g1s005vfio.inp 3,825 11-18-2019 10:55 d79c60cc hk_na325e2c51g1s005vfio.out 650,446 11-19-2019 01:51 b302f5ed hk_na325e2c51g1s010vfio.inp 3,825 11-18-2019 10:55 5ef5087b hk_na325e2c51g1s010vfio.out 650,333 11-19-2019 02:00 085eef93 hk_na325e2c51g1s030vfio.inp 3,825 11-18-2019 10:55 e37dea93 hk_na325e2c51g1s030vfio.out 650,588 11-19-2019 02:43 4534c43f hk_na325e2c51g1s050vfio.inp 3,825 11-18-2019 10:55 68336463 hk_na325e2c51g1s050vfio.out 650,695 11-19-2019 03:02 bc4be05c hk_na325e2c51g1s070vfio.inp 3,825 11-18-2019 10:55 b1b094bf hk_na325e2c51g1s070vfio.out 649,782 11-19-2019 02:59 56b402c0 hk_na325e2c51g1s090vfio.inp 3,825 11-18-2019 10:56 f0d2d3b8 hk_na325e2c51g1s090vfio.out 650,177 11-19-2019 03:28 398cd2ba hk_na325e2c51g1s095vfio.inp 3,825 11-18-2019 10:56 751fe392 hk_na325e2c51g1s095vfio.out 651,243 11-19-2019 03:29 9730ce2e hk_na325e2c51g1s100vfio.inp 3,825 11-18-2019 10:56 7c1d1bc0 hk_na325e2c51g1s100vfio.out 649,780 11-19-2019 03:15 a84560e7
\\v1.2\\hl\\ (0) 20,888,018 11-18-2019 15:36
\\v1.2\\hl\\ha245\\ (18) 5,869,894 11-22-2019 12:48 hl_ha245e2c51g1s001vfio.inp 3,613 11-18-2019 09:51 88c4a0a6 hl_ha245e2c51g1s001vfio.out 648,663 11-18-2019 18:07 3e556d68 hl_ha245e2c51g1s005vfio.inp 3,613 11-18-2019 09:51 aaf8e929 hl_ha245e2c51g1s005vfio.out 649,372 11-18-2019 17:41 6e3984c6 hl_ha245e2c51g1s010vfio.inp 3,613 11-18-2019 09:51 15a56ded hl_ha245e2c51g1s010vfio.out 648,946 11-18-2019 17:49 c6c738d2 hl_ha245e2c51g1s030vfio.inp 3,613 11-18-2019 09:51 d00c47b6 hl_ha245e2c51g1s030vfio.out 647,844 11-18-2019 18:26 8450379c hl_ha245e2c51g1s050vfio.inp 3,613 11-18-2019 09:51 d77d5b4b hl_ha245e2c51g1s050vfio.out 648,520 11-18-2019 18:40 d5d9347d hl_ha245e2c51g1s070vfio.inp 3,613 11-18-2019 09:51 0c24497d hl_ha245e2c51g1s070vfio.out 648,380 11-18-2019 18:57 5aaab4cf hl_ha245e2c51g1s090vfio.inp 3,613 11-18-2019 09:51 1e3d17ff hl_ha245e2c51g1s090vfio.out 648,312 11-18-2019 19:04 1e244a88 hl_ha245e2c51g1s095vfio.inp 3,613 11-18-2019 09:51 bce3cd3e hl_ha245e2c51g1s095vfio.out 649,129 11-18-2019 19:00 6d353496 hl_ha245e2c51g1s100vfio.inp 3,613 11-18-2019 09:51 1cf9fc94 hl_ha245e2c51g1s100vfio.out 648,211 11-18-2019 19:11 83e9f728
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
179 of 190
\\v1.2\\hl\\ha325\\ (18) 5,889,532 11-22-2019 12:48 hl_ha325e2c51g1s001vfio.inp 3,800 11-18-2019 01:42 d52b22f9 hl_ha325e2c51g1s001vfio.out 650,442 11-18-2019 08:31 f234bdc3 hl_ha325e2c51g1s005vfio.inp 3,800 11-18-2019 01:42 b4f60e75 hl_ha325e2c51g1s005vfio.out 650,882 11-18-2019 08:10 415d079c hl_ha325e2c51g1s010vfio.inp 3,800 11-18-2019 01:42 ff6fa0fc hl_ha325e2c51g1s010vfio.out 651,038 11-18-2019 08:20 d84913bd hl_ha325e2c51g1s030vfio.inp 3,800 11-18-2019 01:42 60d981c4 hl_ha325e2c51g1s030vfio.out 650,999 11-18-2019 09:08 429a82e1 hl_ha325e2c51g1s050vfio.inp 3,800 11-18-2019 01:43 9ea57bb4 hl_ha325e2c51g1s050vfio.out 649,716 11-18-2019 08:15 a792608f hl_ha325e2c51g1s070vfio.inp 3,800 11-18-2019 01:43 8efb12b7 hl_ha325e2c51g1s070vfio.out 650,767 11-18-2019 09:10 7a6e03a0 hl_ha325e2c51g1s090vfio.inp 3,800 11-18-2019 01:43 ae9204bd hl_ha325e2c51g1s090vfio.out 650,272 11-18-2019 09:05 5135c5a0 hl_ha325e2c51g1s095vfio.inp 3,800 11-18-2019 01:43 1717f134 hl_ha325e2c51g1s095vfio.out 650,254 11-18-2019 09:05 4c015bf2 hl_ha325e2c51g1s100vfio.inp 3,800 11-18-2019 01:43 5eecfcdc hl_ha325e2c51g1s100vfio.out 650,962 11-18-2019 08:23 c2e1afd3
\\v1.2\\hl\\na245\\ (18) 4,555,815 11-22-2019 12:48 hl_na245e2c51g1s001vfio.inp 3,613 11-18-2019 12:01 9f0202ce hl_na245e2c51g1s001vfio.out 503,147 11-19-2019 09:58 2e01d092 hl_na245e2c51g1s005vfio.inp 3,613 11-18-2019 12:01 bd3e4b41 hl_na245e2c51g1s005vfio.out 502,748 11-19-2019 09:26 14082981 hl_na245e2c51g1s010vfio.inp 3,613 11-18-2019 12:01 0263cf85 hl_na245e2c51g1s010vfio.out 502,641 11-19-2019 09:44 04820784 hl_na245e2c51g1s030vfio.inp 3,613 11-18-2019 12:01 c7cae5de hl_na245e2c51g1s030vfio.out 502,427 11-19-2019 10:13 078e8291 hl_na245e2c51g1s050vfio.inp 3,613 11-18-2019 12:01 c0bbf923 hl_na245e2c51g1s050vfio.out 502,380 11-19-2019 10:30 0e1ef923 hl_na245e2c51g1s070vfio.inp 3,613 11-18-2019 12:01 1be2eb15 hl_na245e2c51g1s070vfio.out 503,497 11-19-2019 10:37 69ae49bb hl_na245e2c51g1s090vfio.inp 3,613 11-18-2019 12:01 09fbb597 hl_na245e2c51g1s090vfio.out 502,082 11-19-2019 10:56 5d2e604b hl_na245e2c51g1s095vfio.inp 3,613 11-18-2019 12:01 ab256f56 hl_na245e2c51g1s095vfio.out 502,403 11-19-2019 10:42 370bcbd0 hl_na245e2c51g1s100vfio.inp 3,613 11-18-2019 12:01 0b3f5efc hl_na245e2c51g1s100vfio.out 501,973 11-19-2019 10:49 f3eac799
\\v1.2\\hl\\na325\\ (18) 4,572,777 11-22-2019 12:48 hl_na325e2c51g1s001vfio.inp 3,832 11-18-2019 10:56 ea9fec66 hl_na325e2c51g1s001vfio.out 504,430 11-19-2019 02:27 5577898b hl_na325e2c51g1s005vfio.inp 3,832 11-18-2019 10:56 273b20b3 hl_na325e2c51g1s005vfio.out 504,065 11-19-2019 01:54 9fa38243 hl_na325e2c51g1s010vfio.inp 3,832 11-18-2019 10:56 6c311bc7 hl_na325e2c51g1s010vfio.out 504,383 11-19-2019 01:56 40461632 hl_na325e2c51g1s030vfio.inp 3,832 11-18-2019 10:56 620a6914 hl_na325e2c51g1s030vfio.out 504,094 11-19-2019 02:51 c6c47cee hl_na325e2c51g1s050vfio.inp 3,832 11-18-2019 10:56 0b90c168 hl_na325e2c51g1s050vfio.out 504,348 11-19-2019 02:48 42d3993c hl_na325e2c51g1s070vfio.inp 3,832 11-18-2019 10:56 10830635 hl_na325e2c51g1s070vfio.out 504,136 11-19-2019 03:11 33075635 hl_na325e2c51g1s090vfio.inp 3,832 11-18-2019 10:56 5481606b hl_na325e2c51g1s090vfio.out 504,265 11-19-2019 03:38 0a670fc5 hl_na325e2c51g1s095vfio.inp 3,832 11-18-2019 10:57 6a505824 hl_na325e2c51g1s095vfio.out 504,409 11-19-2019 02:59 97518fe4 hl_na325e2c51g1s100vfio.inp 3,832 11-18-2019 10:57 19dad41c hl_na325e2c51g1s100vfio.out 504,159 11-19-2019 03:40 9d991016
\\v1.2\\ib\\ (0) 65,143,388 11-22-2019 20:34
\\v1.2\\ib\\ha325\\ (198) 65,143,388 11-23-2019 18:06 ib_ha325a1c33g1s001vfi0500hx.inp 4,114 11-22-2019 20:26 f575bd33 ib_ha325a1c33g1s001vfi0500hx.out 654,542 11-22-2019 23:08 b744db9e ib_ha325a1c33g1s001vfi0600hx.inp 4,114 11-22-2019 20:26 41b439ff ib_ha325a1c33g1s001vfi0600hx.out 654,182 11-22-2019 23:24 a0db2a73 ib_ha325a1c33g1s001vfi0700hx.inp 4,114 11-22-2019 20:26 4b86cebc ib_ha325a1c33g1s001vfi0700hx.out 654,357 11-22-2019 23:04 cac86632 ib_ha325a1c33g1s001vfi0800hx.inp 4,114 11-22-2019 20:26 b4ba7ec0 ib_ha325a1c33g1s001vfi0800hx.out 654,087 11-22-2019 23:05 921f1e6c ib_ha325a1c33g1s001vfi0900hx.inp 4,114 11-22-2019 20:26 c6c79710 ib_ha325a1c33g1s001vfi0900hx.out 654,355 11-22-2019 22:58 8eef5348 ib_ha325a1c33g1s001vfi1000hx.inp 4,118 11-22-2019 20:26 ee1513cf ib_ha325a1c33g1s001vfi1000hx.out 653,570 11-22-2019 22:54 188a24a3
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
180 of 190 ib_ha325a1c33g1s001vfi1100hx.inp 4,118 11-22-2019 20:26 4ba75b02 ib_ha325a1c33g1s001vfi1100hx.out 653,504 11-22-2019 22:55 c61e3280 ib_ha325a1c33g1s001vfi1200hx.inp 4,118 11-22-2019 20:26 b318d73d ib_ha325a1c33g1s001vfi1200hx.out 653,811 11-22-2019 22:59 a96fe44a ib_ha325a1c33g1s001vfi1300hx.inp 4,118 11-22-2019 20:26 119ab9aa ib_ha325a1c33g1s001vfi1300hx.out 653,208 11-22-2019 22:40 def57fe0 ib_ha325a1c33g1s001vfi1400hx.inp 4,118 11-22-2019 20:26 073da7df ib_ha325a1c33g1s001vfi1400hx.out 653,815 11-22-2019 23:06 e59275d8 ib_ha325a1c33g1s001vfi1500hx.inp 4,117 11-22-2019 20:26 3cfe42d1 ib_ha325a1c33g1s001vfi1500hx.out 653,410 11-22-2019 23:25 b3877130 ib_ha325a1c33g1s005vfi0500hx.inp 4,114 11-22-2019 20:27 37c8a662 ib_ha325a1c33g1s005vfi0500hx.out 655,309 11-22-2019 22:43 d757252d ib_ha325a1c33g1s005vfi0600hx.inp 4,114 11-22-2019 20:27 830922ae ib_ha325a1c33g1s005vfi0600hx.out 653,968 11-22-2019 22:44 22a7b187 ib_ha325a1c33g1s005vfi0700hx.inp 4,114 11-22-2019 20:27 893bd5ed ib_ha325a1c33g1s005vfi0700hx.out 654,904 11-22-2019 22:38 d651eebd ib_ha325a1c33g1s005vfi0800hx.inp 4,114 11-22-2019 20:27 76076591 ib_ha325a1c33g1s005vfi0800hx.out 653,988 11-22-2019 22:35 3cc44a0f ib_ha325a1c33g1s005vfi0900hx.inp 4,114 11-22-2019 20:27 047a8c41 ib_ha325a1c33g1s005vfi0900hx.out 654,191 11-22-2019 22:36 e51cc379 ib_ha325a1c33g1s005vfi1000hx.inp 4,118 11-22-2019 20:27 13d0f0e3 ib_ha325a1c33g1s005vfi1000hx.out 653,977 11-22-2019 22:40 66eaa860 ib_ha325a1c33g1s005vfi1100hx.inp 4,118 11-22-2019 20:27 b662b82e ib_ha325a1c33g1s005vfi1100hx.out 654,291 11-22-2019 22:24 29f69a06 ib_ha325a1c33g1s005vfi1200hx.inp 4,118 11-22-2019 20:27 4edd3411 ib_ha325a1c33g1s005vfi1200hx.out 654,119 11-22-2019 22:35 55a192f1 ib_ha325a1c33g1s005vfi1300hx.inp 4,118 11-22-2019 20:27 ec5f5a86 ib_ha325a1c33g1s005vfi1300hx.out 653,688 11-22-2019 22:52 c2204c11 ib_ha325a1c33g1s005vfi1400hx.inp 4,118 11-22-2019 20:27 faf844f3 ib_ha325a1c33g1s005vfi1400hx.out 653,753 11-22-2019 22:51 10286485 ib_ha325a1c33g1s005vfi1500hx.inp 4,117 11-22-2019 20:27 9be414cb ib_ha325a1c33g1s005vfi1500hx.out 654,400 11-22-2019 22:56 881031cd ib_ha325a1c33g1s010vfi0500hx.inp 4,114 11-22-2019 20:27 75e844d6 ib_ha325a1c33g1s010vfi0500hx.out 654,095 11-22-2019 22:46 4bb8b051 ib_ha325a1c33g1s010vfi0600hx.inp 4,114 11-22-2019 20:27 c129c01a ib_ha325a1c33g1s010vfi0600hx.out 653,826 11-22-2019 22:41 2e08e0b0 ib_ha325a1c33g1s010vfi0700hx.inp 4,114 11-22-2019 20:28 cb1b3759 ib_ha325a1c33g1s010vfi0700hx.out 653,581 11-22-2019 22:40 f2f4bbf7 ib_ha325a1c33g1s010vfi0800hx.inp 4,114 11-22-2019 20:28 34278725 ib_ha325a1c33g1s010vfi0800hx.out 654,199 11-22-2019 22:45 c644cc39 ib_ha325a1c33g1s010vfi0900hx.inp 4,114 11-22-2019 20:28 465a6ef5 ib_ha325a1c33g1s010vfi0900hx.out 654,260 11-22-2019 21:47 640df277 ib_ha325a1c33g1s010vfi1000hx.inp 4,118 11-22-2019 20:28 42d811da ib_ha325a1c33g1s010vfi1000hx.out 653,827 11-22-2019 22:38 af3eb4a5 ib_ha325a1c33g1s010vfi1100hx.inp 4,118 11-22-2019 20:28 e76a5917 ib_ha325a1c33g1s010vfi1100hx.out 653,384 11-22-2019 22:55 a257764b ib_ha325a1c33g1s010vfi1200hx.inp 4,118 11-22-2019 20:28 1fd5d528 ib_ha325a1c33g1s010vfi1200hx.out 654,291 11-22-2019 22:53 c980c55c ib_ha325a1c33g1s010vfi1300hx.inp 4,118 11-22-2019 20:28 bd57bbbf ib_ha325a1c33g1s010vfi1300hx.out 653,955 11-22-2019 22:58 85faaf99 ib_ha325a1c33g1s010vfi1400hx.inp 4,118 11-22-2019 20:28 abf0a5ca ib_ha325a1c33g1s010vfi1400hx.out 653,594 11-22-2019 22:51 8957df5d ib_ha325a1c33g1s010vfi1500hx.inp 4,117 11-22-2019 20:28 4d0517fa ib_ha325a1c33g1s010vfi1500hx.out 653,835 11-22-2019 22:48 143cc5c9 ib_ha325a1c33g1s030vfi0500hx.inp 4,114 11-22-2019 20:28 4c3a425c ib_ha325a1c33g1s030vfi0500hx.out 653,895 11-22-2019 22:58 5bc33d2f ib_ha325a1c33g1s030vfi0600hx.inp 4,114 11-22-2019 20:28 f8fbc690 ib_ha325a1c33g1s030vfi0600hx.out 654,500 11-22-2019 23:02 2a954ce3 ib_ha325a1c33g1s030vfi0700hx.inp 4,114 11-22-2019 20:28 f2c931d3 ib_ha325a1c33g1s030vfi0700hx.out 653,060 11-22-2019 23:00 37df05c5 ib_ha325a1c33g1s030vfi0800hx.inp 4,114 11-22-2019 20:28 0df581af ib_ha325a1c33g1s030vfi0800hx.out 653,994 11-22-2019 23:18 abd2dbd7 ib_ha325a1c33g1s030vfi0900hx.inp 4,114 11-22-2019 20:28 7f88687f ib_ha325a1c33g1s030vfi0900hx.out 653,950 11-22-2019 23:15 ed2a3d09 ib_ha325a1c33g1s030vfi1000hx.inp 4,118 11-22-2019 20:29 b1f6aa09 ib_ha325a1c33g1s030vfi1000hx.out 653,668 11-22-2019 23:17 83864d91 ib_ha325a1c33g1s030vfi1100hx.inp 4,118 11-22-2019 20:29 1444e2c4 ib_ha325a1c33g1s030vfi1100hx.out 655,036 11-22-2019 23:12 8a191511 ib_ha325a1c33g1s030vfi1200hx.inp 4,118 11-22-2019 20:29 ecfb6efb ib_ha325a1c33g1s030vfi1200hx.out 654,596 11-22-2019 23:09 499779f3 ib_ha325a1c33g1s030vfi1300hx.inp 4,118 11-22-2019 20:29 4e79006c ib_ha325a1c33g1s030vfi1300hx.out 654,057 11-22-2019 23:10 59f67fff ib_ha325a1c33g1s030vfi1400hx.inp 4,118 11-22-2019 20:29 58de1e19 ib_ha325a1c33g1s030vfi1400hx.out 654,094 11-22-2019 23:16 f77a61d3 ib_ha325a1c33g1s030vfi1500hx.inp 4,117 11-22-2019 20:29 dacf8ce8 ib_ha325a1c33g1s030vfi1500hx.out 653,516 11-22-2019 23:06 1058be6b ib_ha325a1c33g1s050vfi0500hx.inp 4,114 11-22-2019 20:29 88edac16 ib_ha325a1c33g1s050vfi0500hx.out 653,823 11-22-2019 23:29 82799398 ib_ha325a1c33g1s050vfi0600hx.inp 4,114 11-22-2019 20:29 3c2c28da ib_ha325a1c33g1s050vfi0600hx.out 653,683 11-22-2019 23:24 1ce9acdf ib_ha325a1c33g1s050vfi0700hx.inp 4,114 11-22-2019 20:29 361edf99
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
181 of 190 ib_ha325a1c33g1s050vfi0700hx.out 653,622 11-22-2019 23:25 ae066973 ib_ha325a1c33g1s050vfi0800hx.inp 4,114 11-22-2019 20:29 c9226fe5 ib_ha325a1c33g1s050vfi0800hx.out 654,445 11-22-2019 23:20 f8cf48db ib_ha325a1c33g1s050vfi0900hx.inp 4,114 11-22-2019 20:29 bb5f8635 ib_ha325a1c33g1s050vfi0900hx.out 653,405 11-22-2019 23:15 93ec103f ib_ha325a1c33g1s050vfi1000hx.inp 4,118 11-22-2019 20:29 6a39f05f ib_ha325a1c33g1s050vfi1000hx.out 652,826 11-22-2019 23:16 d16ba975 ib_ha325a1c33g1s050vfi1100hx.inp 4,118 11-22-2019 20:29 cf8bb892 ib_ha325a1c33g1s050vfi1100hx.out 653,417 11-22-2019 23:21 8323ce8c ib_ha325a1c33g1s050vfi1200hx.inp 4,118 11-22-2019 20:29 373434ad ib_ha325a1c33g1s050vfi1200hx.out 654,426 11-22-2019 23:17 1852cd62 ib_ha325a1c33g1s050vfi1300hx.inp 4,118 11-22-2019 20:30 95b65a3a ib_ha325a1c33g1s050vfi1300hx.out 653,536 11-22-2019 23:36 eb7ef20c ib_ha325a1c33g1s050vfi1400hx.inp 4,118 11-22-2019 20:30 8311444f ib_ha325a1c33g1s050vfi1400hx.out 653,748 11-22-2019 23:34 3dc2eef1 ib_ha325a1c33g1s050vfi1500hx.inp 4,117 11-22-2019 20:30 ae5c0cc2 ib_ha325a1c33g1s050vfi1500hx.out 653,877 11-22-2019 23:37 3a4a1b30 ib_ha325a1c33g1s070vfi0500hx.inp 4,114 11-22-2019 20:30 5aa37ef3 ib_ha325a1c33g1s070vfi0500hx.out 653,673 11-22-2019 23:36 26d3222a ib_ha325a1c33g1s070vfi0600hx.inp 4,114 11-22-2019 20:30 ee62fa3f ib_ha325a1c33g1s070vfi0600hx.out 653,531 11-22-2019 23:30 c3fa1492 ib_ha325a1c33g1s070vfi0700hx.inp 4,114 11-22-2019 20:30 e4500d7c ib_ha325a1c33g1s070vfi0700hx.out 653,392 11-22-2019 23:28 3b51c697 ib_ha325a1c33g1s070vfi0800hx.inp 4,114 11-22-2019 20:30 1b6cbd00 ib_ha325a1c33g1s070vfi0800hx.out 654,558 11-22-2019 23:33 95de8561 ib_ha325a1c33g1s070vfi0900hx.inp 4,114 11-22-2019 20:30 691154d0 ib_ha325a1c33g1s070vfi0900hx.out 654,532 11-22-2019 23:21 57d0f9ff ib_ha325a1c33g1s070vfi1000hx.inp 4,118 11-22-2019 20:30 e54bed3a ib_ha325a1c33g1s070vfi1000hx.out 653,652 11-22-2019 23:40 6c035f69 ib_ha325a1c33g1s070vfi1100hx.inp 4,118 11-22-2019 20:30 40f9a5f7 ib_ha325a1c33g1s070vfi1100hx.out 653,303 11-22-2019 23:37 2a20897e ib_ha325a1c33g1s070vfi1200hx.inp 4,118 11-22-2019 20:30 b84629c8 ib_ha325a1c33g1s070vfi1200hx.out 653,592 11-22-2019 23:40 c6dd8c71 ib_ha325a1c33g1s070vfi1300hx.inp 4,118 11-22-2019 20:30 1ac4475f ib_ha325a1c33g1s070vfi1300hx.out 653,926 11-22-2019 23:37 0ebce18b ib_ha325a1c33g1s070vfi1400hx.inp 4,118 11-22-2019 20:30 0c63592a ib_ha325a1c33g1s070vfi1400hx.out 653,603 11-22-2019 23:33 717004a6 ib_ha325a1c33g1s070vfi1500hx.inp 4,117 11-22-2019 20:30 b9df961e ib_ha325a1c33g1s070vfi1500hx.out 653,568 11-22-2019 23:32 c443f718 ib_ha325a1c33g1s090vfi0500hx.inp 4,114 11-22-2019 20:31 061844d1 ib_ha325a1c33g1s090vfi0500hx.out 653,943 11-22-2019 23:39 eb3267e4 ib_ha325a1c33g1s090vfi0600hx.inp 4,114 11-22-2019 20:31 b2d9c01d ib_ha325a1c33g1s090vfi0600hx.out 653,361 11-22-2019 23:29 b08e3a19 ib_ha325a1c33g1s090vfi0700hx.inp 4,114 11-22-2019 20:31 b8eb375e ib_ha325a1c33g1s090vfi0700hx.out 654,188 11-22-2019 23:47 17993132 ib_ha325a1c33g1s090vfi0800hx.inp 4,114 11-22-2019 20:31 47d78722 ib_ha325a1c33g1s090vfi0800hx.out 653,566 11-22-2019 23:43 aa84ef8f ib_ha325a1c33g1s090vfi0900hx.inp 4,114 11-22-2019 20:31 35aa6ef2 ib_ha325a1c33g1s090vfi0900hx.out 653,565 11-22-2019 23:47 0c7d9dd6 ib_ha325a1c33g1s090vfi1000hx.inp 4,118 11-22-2019 20:31 e8834d44 ib_ha325a1c33g1s090vfi1000hx.out 653,879 11-22-2019 23:42 9657081d ib_ha325a1c33g1s090vfi1100hx.inp 4,118 11-22-2019 20:31 4d310589 ib_ha325a1c33g1s090vfi1100hx.out 653,690 11-22-2019 23:38 dec07eae ib_ha325a1c33g1s090vfi1200hx.inp 4,118 11-22-2019 20:31 b58e89b6 ib_ha325a1c33g1s090vfi1200hx.out 654,721 11-22-2019 23:36 f6ba34fb ib_ha325a1c33g1s090vfi1300hx.inp 4,118 11-22-2019 20:31 170ce721 ib_ha325a1c33g1s090vfi1300hx.out 653,958 11-22-2019 23:41 eb5dfa37 ib_ha325a1c33g1s090vfi1400hx.inp 4,118 11-22-2019 20:31 01abf954 ib_ha325a1c33g1s090vfi1400hx.out 654,696 11-22-2019 23:31 307e13df ib_ha325a1c33g1s090vfi1500hx.inp 4,117 11-22-2019 20:31 1c15d694 ib_ha325a1c33g1s090vfi1500hx.out 654,036 11-22-2019 23:51 fd0976c1 ib_ha325a1c33g1s095vfi0500hx.inp 4,114 11-22-2019 20:31 002acf80 ib_ha325a1c33g1s095vfi0500hx.out 654,106 11-22-2019 23:45 7e63e7e0 ib_ha325a1c33g1s095vfi0600hx.inp 4,114 11-22-2019 20:31 b4eb4b4c ib_ha325a1c33g1s095vfi0600hx.out 653,752 11-22-2019 23:47 19976f90 ib_ha325a1c33g1s095vfi0700hx.inp 4,114 11-22-2019 20:31 bed9bc0f ib_ha325a1c33g1s095vfi0700hx.out 653,922 11-22-2019 23:40 ea0ae1b1 ib_ha325a1c33g1s095vfi0800hx.inp 4,114 11-22-2019 20:32 41e50c73 ib_ha325a1c33g1s095vfi0800hx.out 653,890 11-22-2019 23:38 46f94d01 ib_ha325a1c33g1s095vfi0900hx.inp 4,114 11-22-2019 20:32 3398e5a3 ib_ha325a1c33g1s095vfi0900hx.out 654,059 11-22-2019 23:35 5e7dceac ib_ha325a1c33g1s095vfi1000hx.inp 4,118 11-22-2019 20:32 55f170eb ib_ha325a1c33g1s095vfi1000hx.out 654,505 11-22-2019 23:41 22dd87b9 ib_ha325a1c33g1s095vfi1100hx.inp 4,118 11-22-2019 20:32 f0433826 ib_ha325a1c33g1s095vfi1100hx.out 654,134 11-22-2019 23:30 0c673352 ib_ha325a1c33g1s095vfi1200hx.inp 4,118 11-22-2019 20:32 08fcb419 ib_ha325a1c33g1s095vfi1200hx.out 652,758 11-22-2019 23:51 01b6b1a6 ib_ha325a1c33g1s095vfi1300hx.inp 4,118 11-22-2019 20:32 aa7eda8e ib_ha325a1c33g1s095vfi1300hx.out 654,359 11-22-2019 23:47 2aec538d ib_ha325a1c33g1s095vfi1400hx.inp 4,118 11-22-2019 20:32 bcd9c4fb ib_ha325a1c33g1s095vfi1400hx.out 653,641 11-22-2019 23:51 70c2b5f7
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
182 of 190 ib_ha325a1c33g1s095vfi1500hx.inp 4,117 11-22-2019 20:32 d3da6564 ib_ha325a1c33g1s095vfi1500hx.out 653,626 11-22-2019 23:48 07d7b785 ib_ha325a1c33g1s100vfi0500hx.inp 4,114 11-22-2019 20:32 c2f96094 ib_ha325a1c33g1s100vfi0500hx.out 654,205 11-22-2019 23:39 8c1a04b7 ib_ha325a1c33g1s100vfi0600hx.inp 4,114 11-22-2019 20:32 7638e458 ib_ha325a1c33g1s100vfi0600hx.out 653,614 11-22-2019 23:37 e807e6b0 ib_ha325a1c33g1s100vfi0700hx.inp 4,114 11-22-2019 20:32 7c0a131b ib_ha325a1c33g1s100vfi0700hx.out 653,623 11-22-2019 23:41 c7a65a55 ib_ha325a1c33g1s100vfi0800hx.inp 4,114 11-22-2019 20:32 8336a367 ib_ha325a1c33g1s100vfi0800hx.out 653,981 11-22-2019 23:29 44ac5998 ib_ha325a1c33g1s100vfi0900hx.inp 4,114 11-22-2019 20:32 f14b4ab7 ib_ha325a1c33g1s100vfi0900hx.out 654,050 11-22-2019 23:50 377e2f95 ib_ha325a1c33g1s100vfi1000hx.inp 4,118 11-22-2019 20:32 1ca9f0da ib_ha325a1c33g1s100vfi1000hx.out 653,648 11-22-2019 23:46 88feaa34 ib_ha325a1c33g1s100vfi1100hx.inp 4,118 11-22-2019 20:33 b91bb817 ib_ha325a1c33g1s100vfi1100hx.out 652,763 11-22-2019 23:50 47aba60e ib_ha325a1c33g1s100vfi1200hx.inp 4,118 11-22-2019 20:33 41a43428 ib_ha325a1c33g1s100vfi1200hx.out 653,564 11-22-2019 23:43 250ee4e1 ib_ha325a1c33g1s100vfi1300hx.inp 4,118 11-22-2019 20:33 e3265abf ib_ha325a1c33g1s100vfi1300hx.out 653,842 11-22-2019 23:39 69f4c8a2 ib_ha325a1c33g1s100vfi1400hx.inp 4,118 11-22-2019 20:33 f58144ca ib_ha325a1c33g1s100vfi1400hx.out 654,080 11-22-2019 23:40 dafc2847 ib_ha325a1c33g1s100vfi1500hx.inp 4,117 11-22-2019 20:33 e21d1982 ib_ha325a1c33g1s100vfi1500hx.out 653,390 11-22-2019 23:45 404f8a27
\\ja\\ (0) 7,240,091 01-09-2020 22:56
\\ja\\ha325\\ (22) 7,240,091 01-10-2020 04:18 ja_ha325a1c33g1s0500hx.inp 4,153 01-09-2020 22:54 9a9dbe0e ja_ha325a1c33g1s0500hx.out 653,595 01-10-2020 02:05 00c6c290 ja_ha325a1c33g1s0600hx.inp 4,153 01-09-2020 22:54 7ab2fd1d ja_ha325a1c33g1s0600hx.out 654,399 01-10-2020 02:04 242cca03 ja_ha325a1c33g1s0700hx.inp 4,153 01-09-2020 22:54 aa82e7a1 ja_ha325a1c33g1s0700hx.out 654,435 01-10-2020 02:00 3dfb2b6e ja_ha325a1c33g1s0800hx.inp 4,153 01-09-2020 22:54 dc239a56 ja_ha325a1c33g1s0800hx.out 653,984 01-10-2020 01:59 c5cedb04 ja_ha325a1c33g1s0900hx.inp 4,153 01-09-2020 22:54 7223b39c ja_ha325a1c33g1s0900hx.out 653,842 01-10-2020 02:03 56abf158 ja_ha325a1c33g1s1000hx.inp 4,157 01-09-2020 22:54 9f4f70de ja_ha325a1c33g1s1000hx.out 653,030 01-10-2020 02:01 ef41f0bb ja_ha325a1c33g1s1100hx.inp 4,157 01-09-2020 22:55 846305e0 ja_ha325a1c33g1s1100hx.out 654,300 01-10-2020 02:00 fd8a4b95 ja_ha325a1c33g1s1200hx.inp 4,157 01-09-2020 22:55 49952e43 ja_ha325a1c33g1s1200hx.out 653,897 01-10-2020 02:01 24738481 ja_ha325a1c33g1s1300hx.inp 4,157 01-09-2020 22:55 fed2790f ja_ha325a1c33g1s1300hx.out 654,384 01-10-2020 02:05 d120b183 ja_ha325a1c33g1s1400hx.inp 4,157 01-09-2020 22:55 1e7e02b7 ja_ha325a1c33g1s1400hx.out 654,224 01-10-2020 02:04 66cb6432 ja_ha325a1c33g1s1500hx.inp 4,156 01-09-2020 22:55 124efc7d ja_ha325a1c33g1s1500hx.out 654,295 01-10-2020 00:55 d32c7105
\\jb\\ (0) 7,175,510 01-10-2020 08:32
\\jb\\ha245\\ (22) 7,175,510 01-10-2020 08:34 jb_ha245e2c51g1s0500hx.inp 3,608 01-10-2020 05:30 2773cff1 jb_ha245e2c51g1s0500hx.out 647,986 01-10-2020 08:34 3d721a41 jb_ha245e2c51g1s0600hx.inp 3,609 01-10-2020 05:30 aad7eeee jb_ha245e2c51g1s0600hx.out 648,446 01-10-2020 08:32 08782160 jb_ha245e2c51g1s0700hx.inp 3,609 01-10-2020 05:31 4af2fe65 jb_ha245e2c51g1s0700hx.out 647,912 01-10-2020 08:29 e6c13488 jb_ha245e2c51g1s0800hx.inp 3,609 01-10-2020 05:31 97eae467 jb_ha245e2c51g1s0800hx.out 648,860 01-10-2020 08:29 28ae1bcd jb_ha245e2c51g1s0900hx.inp 3,609 01-10-2020 05:31 72efdeea jb_ha245e2c51g1s0900hx.out 648,875 01-10-2020 08:30 67b3fd52 jb_ha245e2c51g1s1000hx.inp 3,613 01-10-2020 05:31 449a8e87 jb_ha245e2c51g1s1000hx.out 648,502 01-10-2020 08:30 8f520ff1 jb_ha245e2c51g1s1100hx.inp 3,613 01-10-2020 05:31 d67b72b0 jb_ha245e2c51g1s1100hx.out 649,377 01-10-2020 08:30 60862b53 jb_ha245e2c51g1s1200hx.inp 3,613 01-10-2020 05:31 97e15f43 jb_ha245e2c51g1s1200hx.out 648,535 01-10-2020 08:31 17e167df jb_ha245e2c51g1s1300hx.inp 3,613 01-10-2020 05:31 dd673dab jb_ha245e2c51g1s1300hx.out 649,333 01-10-2020 08:31 256f2380 jb_ha245e2c51g1s1400hx.inp 3,613 01-10-2020 05:31 408522ed jb_ha245e2c51g1s1400hx.out 648,877 01-10-2020 08:32 200b0718 jb_ha245e2c51g1s1500hx.inp 3,613 01-10-2020 05:31 9967e34b jb_ha245e2c51g1s1500hx.out 649,085 01-10-2020 07:21 f0b80eab
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
183 of 190
\\Validation\\ (0) 192,216,466 11-25-2019 09:25
\\Validation\\Excel\\ (1) 657,559 11-25-2019 09:25 nwp_vv_v1005.xlsm 657,559 11-25-2019 09:19 fab5e09c
\\Validation\\lct009\\ (54) 18,976,663 11-25-2019 09:23 LCT-009-01.inp 2,947 11-16-2019 14:11 5c6a1108 LCT-009-01.out 700,107 11-16-2019 18:01 c45863e8 LCT-009-02.inp 2,947 11-16-2019 14:11 ac81d82d LCT-009-02.out 699,562 11-16-2019 18:23 f6ff587e LCT-009-03.inp 2,953 11-16-2019 14:11 2b6b8347 LCT-009-03.out 700,316 11-16-2019 17:22 cf1ca13e LCT-009-04.inp 2,952 11-16-2019 14:11 e01d2aa6 LCT-009-04.out 699,566 11-16-2019 18:00 9ce188f5 LCT-009-05.inp 3,022 11-16-2019 14:11 86d03ca3 LCT-009-05.out 700,794 11-16-2019 18:18 e063bcc9 LCT-009-06.inp 3,022 11-16-2019 14:11 72d2c159 LCT-009-06.out 701,038 11-16-2019 17:15 486e6cfe LCT-009-07.inp 3,022 11-16-2019 14:11 7c648a50 LCT-009-07.out 700,233 11-16-2019 17:49 7b840887 LCT-009-08.inp 3,021 11-16-2019 14:11 9cb3081d LCT-009-08.out 700,997 11-16-2019 18:15 e3a3bde8 LCT-009-09-2.inp 3,573 11-16-2019 14:11 926c97d4 LCT-009-09-2.out 708,679 11-16-2019 16:05 5f15e0b4 LCT-009-10.inp 3,013 11-16-2019 14:11 e75ef8f0 LCT-009-10.out 696,387 11-16-2019 17:53 8edf34de LCT-009-11-2.inp 3,013 11-16-2019 14:11 5488663f LCT-009-11-2.out 697,037 11-16-2019 18:19 46a1f9a0 LCT-009-12-2.inp 3,631 11-16-2019 14:11 08c6dfc4 LCT-009-12-2.out 704,034 11-16-2019 18:00 342b5d78 LCT-009-13.inp 3,015 11-16-2019 14:11 151de6fa LCT-009-13.out 697,091 11-16-2019 18:22 86a04a32 LCT-009-14.inp 3,764 11-16-2019 14:11 e9ff127d LCT-009-14.out 715,500 11-16-2019 18:15 9e048a3e LCT-009-15.inp 3,139 11-16-2019 14:11 3f0564b7 LCT-009-15.out 708,598 11-16-2019 18:20 3d560ca1 LCT-009-16.inp 2,813 11-16-2019 14:11 16f4caa6 LCT-009-16.out 695,699 11-16-2019 17:48 e94899ba LCT-009-17-2.inp 2,811 11-16-2019 14:11 40489e3a LCT-009-17-2.out 696,149 11-16-2019 18:15 a7f6d577 LCT-009-18.inp 2,812 11-16-2019 14:11 858748f6 LCT-009-18.out 695,851 11-16-2019 17:48 417e0ae4 LCT-009-19.inp 2,811 11-16-2019 14:11 d9b09ab3 LCT-009-19.out 695,609 11-16-2019 18:15 62a8dfed LCT-009-20.inp 2,812 11-16-2019 14:11 28e605d8 LCT-009-20.out 696,327 11-16-2019 17:45 6cb4c6c8 LCT-009-21.inp 2,811 11-16-2019 14:11 01359f13 LCT-009-21.out 695,749 11-16-2019 18:12 5834b9bf LCT-009-22.inp 2,810 11-16-2019 14:11 ddddb386 LCT-009-22.out 696,240 11-16-2019 17:45 fb383a83 LCT-009-23.inp 2,811 11-16-2019 14:11 0f81c4c9 LCT-009-23.out 697,466 11-16-2019 18:10 25dbe1c0 LCT-009-24-3.inp 3,005 11-16-2019 14:11 e8368186 LCT-009-24-3.out 698,528 11-16-2019 18:03 e5508369 LCT-009-25-2.inp 3,005 11-16-2019 14:11 5738db43 LCT-009-25-2.out 697,698 11-16-2019 18:29 34835533 LCT-009-26.inp 2,883 11-16-2019 14:11 0a9bf504 LCT-009-26.out 700,805 11-16-2019 18:18 0aecca2a LCT-009-27-2.inp 2,883 11-16-2019 14:11 d5204906 LCT-009-27-2.out 699,302 11-16-2019 18:55 cc3b21a5
\\Validation\\lct010\\ (60) 20,786,877 11-25-2019 09:24 LCT-010-01.inp 2,092 11-09-2019 00:54 b6b7a927 LCT-010-01.out 686,355 11-09-2019 04:36 ee7ccbf4 LCT-010-02.inp 2,070 11-09-2019 00:54 ec5563db LCT-010-02.out 687,855 11-09-2019 04:48 da4706b1 LCT-010-03.inp 2,073 11-09-2019 00:54 74ca7d8e LCT-010-03.out 688,034 11-09-2019 04:48 3ae040db LCT-010-04.inp 2,071 11-09-2019 00:54 83090df0 LCT-010-04.out 687,134 11-09-2019 04:42 0a92997f LCT-010-05.inp 2,068 11-09-2019 00:54 8bab6d54 LCT-010-05.out 686,596 11-09-2019 04:02 72caaab9 LCT-010-06.inp 2,113 11-09-2019 00:54 f6773c7d LCT-010-06.out 687,054 11-09-2019 03:44 30d1936b LCT-010-07.inp 2,112 11-09-2019 00:54 aabdd47f LCT-010-07.out 686,243 11-09-2019 04:27 d8825722
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
184 of 190 LCT-010-08.inp 2,114 11-09-2019 00:54 06102e42 LCT-010-08.out 686,662 11-09-2019 04:13 17c371c1 LCT-010-09.inp 2,307 11-09-2019 00:54 e675e81f LCT-010-09.out 696,809 11-09-2019 04:20 0b38fe44 LCT-010-10.inp 2,350 11-09-2019 00:54 2edf207c LCT-010-10.out 697,349 11-09-2019 04:10 29857e5c LCT-010-11.inp 2,350 11-09-2019 00:54 aa0f4166 LCT-010-11.out 697,211 11-09-2019 04:13 10695f8d LCT-010-12.inp 2,350 11-09-2019 00:54 75188917 LCT-010-12.out 697,333 11-09-2019 04:04 94f41137 LCT-010-13.inp 2,348 11-09-2019 00:54 dfd7bc41 LCT-010-13.out 696,717 11-09-2019 04:18 e5d19b20 LCT-010-14.inp 2,352 11-09-2019 00:54 d4f23467 LCT-010-14.out 696,201 11-09-2019 04:49 0053855b LCT-010-15.inp 2,352 11-09-2019 00:54 805f1d17 LCT-010-15.out 696,724 11-09-2019 04:49 51fa7204 LCT-010-16.inp 2,352 11-09-2019 00:54 467f2662 LCT-010-16.out 696,586 11-09-2019 04:32 ecb1257a LCT-010-17.inp 2,352 11-09-2019 00:54 dcd6c7ac LCT-010-17.out 697,325 11-09-2019 04:31 fb14316e LCT-010-18.inp 2,353 11-09-2019 00:54 965db8cc LCT-010-18.out 696,925 11-09-2019 04:30 4968bc47 LCT-010-19.inp 2,353 11-09-2019 00:54 262f83e3 LCT-010-19.out 697,103 11-09-2019 04:30 79a366b5 LCT-010-20.inp 2,028 11-09-2019 00:54 05a9e64b LCT-010-20.out 688,237 11-09-2019 04:51 5d7550d1 LCT-010-21.inp 2,072 11-09-2019 00:54 ca5f7d16 LCT-010-21.out 687,632 11-09-2019 05:11 5e04f6dd LCT-010-22.inp 2,075 11-09-2019 00:54 bf641b07 LCT-010-22.out 688,315 11-09-2019 04:40 e6128fbc LCT-010-23.inp 2,074 11-09-2019 00:54 78a4aa9b LCT-010-23.out 687,887 11-09-2019 04:48 e53622db LCT-010-24.inp 2,070 11-09-2019 00:54 ce04b098 LCT-010-24.out 686,371 11-09-2019 04:35 aa82dc19 LCT-010-25.inp 2,115 11-09-2019 00:54 636569ad LCT-010-25.out 686,388 11-09-2019 04:17 96bc823b LCT-010-26.inp 2,114 11-09-2019 00:54 3854dcb6 LCT-010-26.out 687,486 11-09-2019 04:34 f9687e17 LCT-010-27.inp 2,115 11-09-2019 00:54 8bef8f3a LCT-010-27.out 686,538 11-09-2019 04:36 daf6d5c6 LCT-010-28.inp 2,114 11-09-2019 00:54 066a87ed LCT-010-28.out 687,050 11-09-2019 04:41 e0a611c1 LCT-010-29.inp 2,114 11-09-2019 00:54 15db05bc LCT-010-29.out 686,368 11-09-2019 04:30 ef227182 LCT-010-30.inp 2,113 11-09-2019 00:54 e015b636 LCT-010-30.out 686,853 11-09-2019 04:32 b78b1d8e
\\Validation\\pust\\ (392) 131,316,363 11-25-2019 09:27 pust001_case_1.inp 937 10-28-2019 19:39 7a0a09dd pust001_case_1.out 819,673 10-28-2019 23:02 a79889d0 pust001_case_2.inp 936 10-28-2019 19:39 190e3e4f pust001_case_2.out 819,124 10-28-2019 23:04 411731ac pust001_case_3.inp 938 10-28-2019 19:39 4e6b0e79 pust001_case_3.out 819,351 10-28-2019 23:00 7557eb4c pust001_case_4.inp 937 10-28-2019 19:39 fba56e0b pust001_case_4.out 819,145 10-28-2019 22:59 f5526112 pust001_case_5.inp 937 10-28-2019 19:39 21129e33 pust001_case_5.out 819,327 10-28-2019 22:51 cd77f219 pust001_case_6.inp 943 10-28-2019 19:39 670df8d2 pust001_case_6.out 819,823 10-28-2019 22:56 760085c7 pust002_case_1.inp 845 10-28-2019 19:39 6ea3b9f3 pust002_case_1.out 818,810 10-28-2019 23:05 3949140e pust002_case_2.inp 845 10-28-2019 19:39 ac974019 pust002_case_2.out 818,396 10-28-2019 23:09 6d8ac1c5 pust002_case_3.inp 845 10-28-2019 19:39 cf0f71a0 pust002_case_3.out 818,306 10-28-2019 23:05 0997230b pust002_case_4.inp 845 10-28-2019 19:39 797c0ebe pust002_case_4.out 817,628 10-28-2019 23:10 0a64678b pust002_case_5.inp 851 10-28-2019 19:39 6271166c pust002_case_5.out 819,457 10-28-2019 23:08 cb369b23 pust002_case_6.inp 851 10-28-2019 19:39 2d70bb34 pust002_case_6.out 819,037 10-28-2019 23:04 058b4c88 pust002_case_7.inp 845 10-28-2019 19:39 d3f94b9f pust002_case_7.out 817,150 10-28-2019 23:04 caaa00f5 pust003_case_1.inp 1,004 10-28-2019 19:39 f309be10 pust003_case_1.out 819,865 10-28-2019 23:13 3286896c pust003_case_2.inp 1,004 10-28-2019 19:39 b84a7c03 pust003_case_2.out 820,202 10-28-2019 23:11 bf484c26 pust003_case_3.inp 1,004 10-28-2019 19:39 5085b459 pust003_case_3.out 819,705 10-28-2019 23:07 b6ae8778
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
185 of 190 pust003_case_4.inp 1,004 10-28-2019 19:39 16803b62 pust003_case_4.out 819,629 10-28-2019 23:11 1951ebff pust003_case_5.inp 1,004 10-28-2019 19:39 2bb7772a pust003_case_5.out 820,106 10-28-2019 23:11 8c9344fe pust003_case_6.inp 1,004 10-28-2019 19:39 8a037d6b pust003_case_6.out 819,929 10-28-2019 23:07 1f729d88 pust003_case_7.inp 1,004 10-28-2019 19:39 494c0135 pust003_case_7.out 818,570 10-28-2019 23:19 48603660 pust003_case_8.inp 1,004 10-28-2019 19:39 8b86ca29 pust003_case_8.out 818,837 10-28-2019 23:19 d76fdef9 pust004_case_1.inp 855 10-28-2019 19:39 844048f9 pust004_case_1.out 819,124 10-28-2019 23:18 b67aaf7b pust004_case_2.inp 852 10-28-2019 19:39 8333ddfc pust004_case_2.out 818,408 10-28-2019 23:25 ad689678 pust004_case_3.inp 851 10-28-2019 19:39 580ed1b5 pust004_case_3.out 818,494 10-28-2019 23:23 1b9c81db pust004_case_4.inp 848 10-28-2019 19:39 93a9341f pust004_case_4.out 818,814 10-28-2019 23:16 e0fe19ea pust004_case_5.inp 851 10-28-2019 19:39 e3745cf5 pust004_case_5.out 817,978 10-28-2019 23:26 a0daef4a pust004_case_6.inp 851 10-28-2019 19:39 e5e3569a pust004_case_6.out 818,166 10-28-2019 23:26 1b7c5c53 pust004_case_7.inp 851 10-28-2019 19:39 5a3f7338 pust004_case_7.out 818,418 10-28-2019 23:22 b9cf6bcd pust004_case_8.inp 851 10-28-2019 19:39 5b940060 pust004_case_8.out 819,899 10-28-2019 23:27 695e8336 pust004_case_9.inp 851 10-28-2019 19:39 d46106ff pust004_case_9.out 818,985 10-28-2019 23:18 fd8034c5 pust004_case_10.inp 853 10-28-2019 19:39 4b2aa2de pust004_case_10.out 818,564 10-28-2019 23:15 04554ef6 pust004_case_11.inp 853 10-28-2019 19:39 8887f913 pust004_case_11.out 819,142 10-28-2019 23:11 9b2bc358 pust004_case_12.inp 853 10-28-2019 19:39 6620225f pust004_case_12.out 819,491 10-28-2019 23:19 d64c3da7 pust004_case_13.inp 853 10-28-2019 19:39 345bdfe7 pust004_case_13.out 817,796 10-28-2019 23:13 482e2f06 pust005_case_1.inp 847 10-28-2019 19:39 fefc618f pust005_case_1.out 819,219 10-28-2019 23:24 6bf14272 pust005_case_2.inp 849 10-28-2019 19:39 b93f7476 pust005_case_2.out 818,194 10-28-2019 23:21 e92f1da9 pust005_case_3.inp 845 10-28-2019 19:39 c6451d9f pust005_case_3.out 818,482 10-28-2019 23:20 5e40d542 pust005_case_4.inp 848 10-28-2019 19:39 4d9c5412 pust005_case_4.out 819,033 10-28-2019 23:21 9fe96376 pust005_case_5.inp 845 10-28-2019 19:39 75776cc8 pust005_case_5.out 818,377 10-28-2019 23:20 6986a50d pust005_case_6.inp 845 10-28-2019 19:39 00ef4e51 pust005_case_6.out 818,502 10-28-2019 23:22 431d7066 pust005_case_7.inp 845 10-28-2019 19:39 05359628 pust005_case_7.out 818,711 10-28-2019 23:16 c75a15d0 pust005_case_8.inp 845 10-28-2019 19:39 17a0fba0 pust005_case_8.out 819,019 10-28-2019 23:22 1f98fd5f pust005_case_9.inp 845 10-28-2019 19:39 f5369cce pust005_case_9.out 819,333 10-28-2019 23:11 9ab43c96 pust006_case_1.inp 942 10-28-2019 19:39 ebe029c5 pust006_case_1.out 660,241 10-28-2019 23:33 53693527 pust006_case_2.inp 921 10-28-2019 19:39 d1e10c5e pust006_case_2.out 660,300 10-28-2019 23:27 29dd441b pust006_case_3.inp 901 10-28-2019 19:39 b8a61672 pust006_case_3.out 660,327 10-28-2019 23:25 fd6b9ade pust007_case_2.inp 986 10-28-2019 19:39 8b691209 pust007_case_2.out 858,808 10-28-2019 23:24 10c896bb pust007_case_3.inp 986 10-28-2019 19:39 e5bfc58f pust007_case_3.out 857,521 10-28-2019 23:27 d9cc1572 pust007_case_5.inp 985 10-28-2019 19:39 f859120e pust007_case_5.out 858,916 10-28-2019 23:37 b0769d72 pust007_case_6.inp 985 10-28-2019 19:39 6ee7113c pust007_case_6.out 857,260 10-28-2019 23:32 1ba18993 pust007_case_7.inp 985 10-28-2019 19:39 1d9a73a0 pust007_case_7.out 857,355 10-28-2019 23:39 0ef4eedc pust007_case_8.inp 985 10-28-2019 19:39 2b5e6e71 pust007_case_8.out 858,364 10-28-2019 23:33 24db06de pust007_case_9.inp 985 10-28-2019 19:39 ff5a91bc pust007_case_9.out 858,267 10-28-2019 23:35 6195a3d3 pust007_case_10.inp 985 10-28-2019 19:39 1ba7351d pust007_case_10.out 858,548 10-28-2019 23:27 b8f111d2 pust009_case_1.inp 1,467 10-28-2019 19:39 7ac950b0 pust009_case_1.out 842,641 10-29-2019 04:35 5aa012ed pust009_case_2.inp 1,467 10-28-2019 19:39 7491a55e pust009_case_2.out 842,643 10-29-2019 03:53 bc9a8dd1 pust009_case_3.inp 1,422 10-28-2019 19:39 68ee86ea
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
186 of 190 pust009_case_3.out 804,484 10-29-2019 04:02 fe9c4da6 pust010_case_1.9.inp 1,390 10-28-2019 19:39 f35159cf pust010_case_1.9.out 664,407 10-28-2019 23:38 1c6eb7d3 pust010_case_1.11.inp 1,401 10-28-2019 19:39 7dbb525a pust010_case_1.11.out 664,191 10-28-2019 23:34 10a3f259 pust010_case_1.12.inp 1,398 10-28-2019 19:39 c51efcff pust010_case_1.12.out 664,659 10-28-2019 23:39 3d2c2ebe pust010_case_2.9.inp 1,391 10-28-2019 19:39 d04423dc pust010_case_2.9.out 663,139 10-28-2019 23:40 0d56d37a pust010_case_2.11.inp 1,403 10-28-2019 19:39 129839f2 pust010_case_2.11.out 664,405 10-28-2019 23:44 0d62557e pust010_case_2.12.inp 1,400 10-28-2019 19:39 d881e172 pust010_case_2.12.out 664,983 10-28-2019 23:54 f13e904a pust010_case_3.9.inp 1,399 10-28-2019 19:39 1d3794af pust010_case_3.9.out 664,155 10-28-2019 23:44 135b3ad6 pust010_case_3.11.inp 1,386 10-28-2019 19:39 ee25dc02 pust010_case_3.11.out 663,757 10-28-2019 23:44 1c3b0de0 pust010_case_3.12.inp 1,398 10-28-2019 19:39 2f3f986e pust010_case_3.12.out 664,498 10-28-2019 23:41 edb7e1b4 pust010_case_4.11.inp 1,397 10-28-2019 19:39 6c82e546 pust010_case_4.11.out 664,456 10-28-2019 23:41 316a3c64 pust010_case_4.12.inp 1,400 10-28-2019 19:39 92bc7426 pust010_case_4.12.out 664,463 10-28-2019 23:51 6f494221 pust010_case_5.11.inp 1,400 10-28-2019 19:39 d6245c76 pust010_case_5.11.out 664,170 10-28-2019 23:50 4eaaf796 pust010_case_6.11.inp 1,403 10-28-2019 19:39 b8c894aa pust010_case_6.11.out 663,558 10-28-2019 23:46 6cfb0266 pust010_case_7.11.inp 1,401 10-28-2019 19:39 79067971 pust010_case_7.11.out 664,375 10-28-2019 23:46 034b9cf9 pust011_case_1.16.inp 774 10-28-2019 19:39 90408899 pust011_case_1.16.out 657,923 10-28-2019 21:43 dcca8347 pust011_case_1.18.inp 902 10-28-2019 19:39 24c1bb1d pust011_case_1.18.out 663,806 10-28-2019 22:03 a8e2a537 pust011_case_2.16.inp 774 10-28-2019 19:39 e6f0eec9 pust011_case_2.16.out 657,285 10-28-2019 21:40 89ac48f9 pust011_case_2.18.inp 902 10-28-2019 19:39 160d1b91 pust011_case_2.18.out 662,999 10-28-2019 21:59 29f177d4 pust011_case_3.16.inp 774 10-28-2019 19:39 ca3a21b1 pust011_case_3.16.out 658,590 10-28-2019 21:38 bf9d14ef pust011_case_3.18.inp 904 10-28-2019 19:39 76d5fb18 pust011_case_3.18.out 662,578 10-28-2019 22:04 c5bcffad pust011_case_4.16.inp 774 10-28-2019 19:39 a61785c5 pust011_case_4.16.out 657,535 10-28-2019 21:45 f99be3fe pust011_case_4.18.inp 901 10-28-2019 19:39 d2b8d3fc pust011_case_4.18.out 663,812 10-28-2019 22:07 74491e17 pust011_case_5.16.inp 774 10-28-2019 19:39 1647cb37 pust011_case_5.16.out 658,077 10-28-2019 21:51 bd681589 pust011_case_5.18.inp 901 10-28-2019 19:39 54f9cb48 pust011_case_5.18.out 663,492 10-28-2019 22:39 33de4492 pust011_case_6.18.inp 901 10-28-2019 19:39 68e27933 pust011_case_6.18.out 663,605 10-28-2019 22:44 8c54f609 pust011_case_7.18.inp 902 10-28-2019 19:39 ab9e9fca pust011_case_7.18.out 662,948 10-28-2019 23:00 af117f63 pust014_case_1.inp 2,539 10-30-2019 18:57 7622ef5a pust014_case_1.out 518,571 10-30-2019 22:35 cb629c67 pust014_case_3.inp 2,541 10-30-2019 18:57 6df0d268 pust014_case_3.out 518,530 10-30-2019 22:34 ec71d88f pust014_case_4.inp 2,570 10-30-2019 18:57 3916c581 pust014_case_4.out 519,792 10-30-2019 22:23 021ce2a1 pust014_case_5.inp 2,541 10-30-2019 18:57 36827dc0 pust014_case_5.out 519,374 10-30-2019 22:00 6b9ed730 pust014_case_6.inp 2,542 10-30-2019 18:57 485cdd73 pust014_case_6.out 678,301 10-30-2019 23:23 6e191cfc pust014_case_7.inp 2,547 10-30-2019 18:57 e8e32cf3 pust014_case_7.out 518,417 10-30-2019 22:35 3559aa91 pust014_case_8.inp 2,519 10-30-2019 18:57 42f9bd71 pust014_case_8.out 519,083 10-30-2019 22:45 d7cc1dfe pust014_case_9.inp 2,520 10-30-2019 18:57 7e0de4a7 pust014_case_9.out 518,376 10-30-2019 22:18 d9f72bba pust014_case_10.inp 2,520 10-30-2019 18:57 c9f63ef5 pust014_case_10.out 519,452 10-30-2019 22:30 4d217b9c pust014_case_11.inp 2,521 10-30-2019 18:57 7f87c80a pust014_case_11.out 678,432 10-30-2019 22:37 83d5cc6c pust014_case_12.inp 2,524 10-30-2019 18:57 b57149ad pust014_case_12.out 677,471 10-30-2019 22:22 aad0a64a pust014_case_13.inp 2,534 10-30-2019 18:57 ac98e437 pust014_case_13.out 519,090 10-30-2019 23:24 0b031500 pust014_case_14.inp 2,528 10-30-2019 18:57 5293708d pust014_case_14.out 518,908 10-30-2019 22:33 faf93446 pust014_case_15.inp 2,529 10-30-2019 18:57 55799319 pust014_case_15.out 519,212 10-30-2019 22:45 90de957c
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
187 of 190 pust014_case_16.inp 2,529 10-30-2019 18:57 439e1653 pust014_case_16.out 518,157 10-30-2019 22:18 13f957d7 pust014_case_17.inp 2,530 10-30-2019 18:57 26096a86 pust014_case_17.out 677,614 10-30-2019 22:27 0d951d26 pust014_case_18.inp 2,579 10-30-2019 18:57 b11b029a pust014_case_18.out 518,658 10-30-2019 22:29 283aa92b pust014_case_19.inp 2,569 10-30-2019 18:57 a900349a pust014_case_19.out 519,310 10-30-2019 22:32 9d6fbcf2 pust014_case_20.inp 2,568 10-30-2019 18:57 7ec4fe02 pust014_case_20.out 518,786 10-30-2019 22:05 fc0e7a74 pust014_case_21.inp 2,570 10-30-2019 18:57 33f37495 pust014_case_21.out 519,727 10-30-2019 23:22 6c805609 pust014_case_22.inp 2,572 10-30-2019 18:57 82f9092f pust014_case_22.out 678,245 10-30-2019 22:32 582fdc04 pust014_case_23.inp 2,574 10-30-2019 18:57 664ac614 pust014_case_23.out 678,462 10-30-2019 22:44 4a6f8745 pust014_case_24.inp 2,632 10-30-2019 18:57 b4ef0101 pust014_case_24.out 519,203 10-30-2019 22:20 0d278503 pust014_case_25.inp 2,653 10-30-2019 18:57 5c842227 pust014_case_25.out 519,732 10-30-2019 22:19 c49cdafc pust014_case_26.inp 2,623 10-30-2019 18:57 7a78a932 pust014_case_26.out 518,653 10-30-2019 22:27 d18fb125 pust014_case_27.inp 2,623 10-30-2019 18:57 859abe4a pust014_case_27.out 520,138 10-30-2019 22:21 7a58baf0 pust014_case_28.inp 2,625 10-30-2019 18:57 1a4ea4d5 pust014_case_28.out 678,590 10-30-2019 21:59 80c0257b pust014_case_29.inp 2,624 10-30-2019 18:57 2550f414 pust014_case_29.out 678,701 10-30-2019 23:21 280a44ae pust014_case_30.inp 2,669 10-30-2019 18:57 777227e9 pust014_case_30.out 518,604 10-30-2019 22:46 cf1f8e9c pust014_case_31.inp 2,662 10-30-2019 18:57 b7fce2dc pust014_case_31.out 518,991 10-30-2019 22:17 b5ebe806 pust014_case_33.inp 2,631 10-30-2019 18:57 197c926d pust014_case_33.out 519,526 10-30-2019 22:18 68cd9f74 pust014_case_34.inp 2,631 10-30-2019 18:57 2659679f pust014_case_34.out 519,780 10-30-2019 22:28 97893b38 pust015_case_1.inp 2,572 10-30-2019 18:57 e449af84 pust015_case_1.out 518,589 10-30-2019 22:18 a24ced79 pust015_case_2.inp 2,572 10-30-2019 18:57 3b169d3e pust015_case_2.out 518,841 10-30-2019 22:21 ee3f8de5 pust015_case_3.inp 2,573 10-30-2019 18:57 8fb49903 pust015_case_3.out 518,726 10-30-2019 23:20 37ec3eb4 pust015_case_4.inp 2,573 10-30-2019 18:57 9ec6efa7 pust015_case_4.out 519,145 10-30-2019 22:29 92a354b4 pust015_case_5.inp 2,573 10-30-2019 18:57 9ddc8963 pust015_case_5.out 519,441 10-30-2019 22:42 a84a931a pust015_case_6.inp 2,524 10-30-2019 18:57 5b5176df pust015_case_6.out 519,172 10-30-2019 22:17 3a6215bf pust015_case_7.inp 2,687 10-30-2019 18:57 f9aa24f7 pust015_case_7.out 519,034 10-30-2019 21:42 630801fc pust015_case_8.inp 2,688 10-30-2019 18:57 c57da314 pust015_case_8.out 519,164 10-30-2019 21:48 1ec8fb83 pust015_case_9.inp 2,688 10-30-2019 18:57 45e6bd24 pust015_case_9.out 519,291 10-30-2019 22:45 a12ab9cb pust015_case_10.inp 2,656 10-30-2019 18:57 5197b7df pust015_case_10.out 519,601 10-30-2019 22:23 c6b355ad pust015_case_11.inp 2,655 10-30-2019 18:57 a0ce2f0e pust015_case_11.out 519,394 10-30-2019 22:21 f998325a pust015_case_12.inp 2,656 10-30-2019 18:57 11ff243e pust015_case_12.out 518,936 10-30-2019 23:21 d81d4d6a pust015_case_13.inp 2,656 10-30-2019 18:57 0f0219b6 pust015_case_13.out 519,549 10-30-2019 22:29 32bedcf8 pust015_case_14.inp 2,656 10-30-2019 18:57 c97b8e08 pust015_case_14.out 519,690 10-30-2019 22:41 aedad670 pust015_case_15.inp 2,674 10-30-2019 18:57 d2b54830 pust015_case_15.out 519,483 10-30-2019 22:15 b53107b6 pust015_case_16.inp 2,663 10-30-2019 18:57 22e2c078 pust015_case_16.out 519,196 10-30-2019 22:16 70398205 pust015_case_17.inp 2,665 10-30-2019 18:57 70cbcbbf pust015_case_17.out 519,673 10-30-2019 22:23 b1dca348 pust016_case_1.inp 2,344 10-30-2019 18:57 7d5986a0 pust016_case_1.out 513,384 10-30-2019 20:59 04d029e6 pust016_case_2.inp 2,343 10-30-2019 18:57 c8782e6b pust016_case_2.out 513,942 10-30-2019 20:39 320954c2 pust016_case_3.inp 2,343 10-30-2019 18:57 4289b998 pust016_case_3.out 514,600 10-30-2019 20:47 440dc727 pust016_case_4.inp 2,343 10-30-2019 18:57 1e3fd929 pust016_case_4.out 514,181 10-30-2019 21:37 0ba7a666 pust016_case_5.inp 2,332 10-30-2019 18:57 cadf86b5 pust016_case_5.out 514,078 10-30-2019 21:01 fd6e01fe pust016_case_6.inp 2,331 10-30-2019 18:57 9b87e205
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
188 of 190 pust016_case_6.out 513,661 10-30-2019 21:13 13ddb4be pust016_case_7.inp 2,331 10-30-2019 18:57 9c9ea309 pust016_case_7.out 514,655 10-30-2019 20:37 c43efd9d pust016_case_8.inp 2,331 10-30-2019 18:57 f42b22ef pust016_case_8.out 513,329 10-30-2019 20:44 2be24786 pust016_case_9.inp 2,279 10-30-2019 18:57 9d73ac49 pust016_case_9.out 510,699 10-30-2019 20:58 55dee946 pust016_case_10.inp 2,278 10-30-2019 18:57 e9bb5b8f pust016_case_10.out 510,236 10-30-2019 21:16 a8ac5f57 pust016_case_11.inp 2,278 10-30-2019 18:57 84bab108 pust016_case_11.out 511,424 10-30-2019 20:39 bb97296c pust017_case_1.inp 2,325 10-30-2019 18:57 2e56b29c pust017_case_1.out 512,928 10-30-2019 21:47 ffaf5c28 pust017_case_2.inp 2,369 10-30-2019 18:57 a458ad75 pust017_case_2.out 514,113 10-30-2019 21:43 9bd1ccdf pust017_case_3.inp 2,369 10-30-2019 18:57 2520d1e4 pust017_case_3.out 513,290 10-30-2019 20:58 0b087e3a pust017_case_4.inp 2,369 10-30-2019 18:57 05d431d0 pust017_case_4.out 513,333 10-30-2019 21:11 2d762f7d pust017_case_5.inp 2,369 10-30-2019 18:57 f22c5373 pust017_case_5.out 513,239 10-30-2019 20:42 b69cbbd9 pust017_case_6.inp 2,369 10-30-2019 18:57 480a89c8 pust017_case_6.out 513,894 10-30-2019 20:53 7ebb6c58 pust017_case_7.inp 2,369 10-30-2019 18:57 eb7e66f5 pust017_case_7.out 514,314 10-30-2019 21:41 59d785b2 pust017_case_8.inp 2,366 10-30-2019 18:57 b3769abf pust017_case_8.out 514,923 10-30-2019 21:00 dae60fa5 pust017_case_9.inp 2,368 10-30-2019 18:57 bb170491 pust017_case_9.out 514,219 10-30-2019 21:13 fbbe2263 pust017_case_10.inp 2,368 10-30-2019 18:57 d5e15431 pust017_case_10.out 513,894 10-30-2019 20:59 1a0e824b pust017_case_11.inp 2,293 10-30-2019 18:57 6f7cd2dc pust017_case_11.out 513,440 10-30-2019 21:15 c815508a pust017_case_12.inp 2,369 10-30-2019 18:57 829038f4 pust017_case_12.out 514,243 10-30-2019 20:44 647b2279 pust017_case_13.inp 2,371 10-30-2019 18:57 f3dfc276 pust017_case_13.out 514,398 10-30-2019 20:53 51cc4849 pust017_case_14.inp 2,369 10-30-2019 18:57 af1d0e53 pust017_case_14.out 513,729 10-30-2019 21:45 a314b776 pust017_case_15.inp 2,369 10-30-2019 18:57 1967df61 pust017_case_15.out 514,229 10-30-2019 21:00 db977bc9 pust017_case_16.inp 2,404 10-30-2019 18:57 a831a1c0 pust017_case_16.out 514,242 10-30-2019 21:13 d588437c pust017_case_17.inp 2,371 10-30-2019 18:57 1233c488 pust017_case_17.out 513,707 10-30-2019 20:44 4637d047 pust017_case_18.inp 2,404 10-30-2019 18:57 7b2168a9 pust017_case_18.out 513,908 10-30-2019 20:52 29dbc151 pust020_case_1.inp 1,005 10-28-2019 19:39 374d4747 pust020_case_1.out 858,485 10-29-2019 00:37 48aa86d6 pust020_case_2.inp 1,006 10-28-2019 19:39 c1c4b5fa pust020_case_2.out 858,439 10-29-2019 00:25 52b54d45 pust020_case_3.inp 1,005 10-28-2019 19:39 40cbe04e pust020_case_3.out 858,592 10-29-2019 00:25 456b156b pust020_case_5.inp 1,005 10-28-2019 19:39 7afabb1d pust020_case_5.out 858,579 10-29-2019 01:01 cf272355 pust020_case_6.inp 1,005 10-28-2019 19:39 84540964 pust020_case_6.out 857,276 10-29-2019 00:33 be2454e7 pust020_case_7.inp 1,005 10-28-2019 19:39 2f99eb34 pust020_case_7.out 858,827 10-29-2019 00:37 0d8f8755 pust020_case_8.inp 1,079 10-28-2019 19:39 8d1e5043 pust020_case_8.out 901,574 10-29-2019 00:32 6f829ed8 pust020_case_9.inp 1,079 10-28-2019 19:39 35e1564a pust020_case_9.out 900,570 10-29-2019 00:42 71eb4e8f pust021_case_7.inp 589 10-28-2019 19:39 7160d775 pust021_case_7.out 733,941 10-28-2019 23:53 45ef1bcf pust021_case_8.inp 591 10-28-2019 19:39 d0ad7f64 pust021_case_8.out 734,341 10-28-2019 23:35 77aa6fe0 pust021_case_9.inp 592 10-28-2019 19:39 52aa51ef pust021_case_9.out 734,153 10-29-2019 00:04 915a3ba2 pust021_case_10.inp 729 10-28-2019 19:39 1875010b pust021_case_10.out 774,669 10-29-2019 01:32 49104084 pust024_case_1.inp 1,908 10-28-2019 19:39 14260b74 pust024_case_1.out 681,055 10-29-2019 00:03 bdb2ff55 pust024_case_2.inp 1,901 10-28-2019 19:39 e5d3d61f pust024_case_2.out 681,372 10-29-2019 00:04 a0f19048 pust024_case_3.inp 1,905 10-28-2019 19:39 f3af62e5 pust024_case_3.out 680,500 10-29-2019 00:12 e91e5059 pust024_case_4.inp 1,905 10-28-2019 19:39 f7a59907 pust024_case_4.out 681,121 10-29-2019 00:10 90684556 pust024_case_5.inp 1,902 10-28-2019 19:39 370a4f77 pust024_case_5.out 681,814 10-28-2019 23:51 599d75c0
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
189 of 190 pust024_case_6.inp 1,922 10-28-2019 19:39 9aa87a80 pust024_case_6.out 680,680 10-29-2019 00:13 847b1856 pust024_case_7.inp 1,922 10-28-2019 19:39 0b45d568 pust024_case_7.out 681,123 10-29-2019 00:10 4d3b40ee pust024_case_8.inp 1,922 10-28-2019 19:39 b8cdd3e0 pust024_case_8.out 681,686 10-29-2019 00:16 7e82c3a7 pust024_case_9.inp 1,918 10-28-2019 19:39 8db5112a pust024_case_9.out 681,640 10-29-2019 00:11 e0990582 pust024_case_10.inp 1,917 10-28-2019 19:39 fde7a96a pust024_case_10.out 681,524 10-29-2019 00:01 0f074539 pust024_case_11.inp 1,919 10-28-2019 19:39 12a269b3 pust024_case_11.out 681,202 10-29-2019 00:03 741d5607 pust024_case_12.inp 1,919 10-28-2019 19:39 d106c905 pust024_case_12.out 680,990 10-29-2019 00:07 72468192 pust024_case_13.inp 1,919 10-28-2019 19:39 a9bb634f pust024_case_13.out 681,421 10-29-2019 00:05 8c2083db pust024_case_14.inp 1,926 10-28-2019 19:39 0eee6fa1 pust024_case_14.out 681,204 10-28-2019 23:59 c3af5e0e pust024_case_15.inp 1,925 10-28-2019 19:39 d9af4e64 pust024_case_15.out 680,779 10-29-2019 00:03 d43d8f5e pust024_case_16.inp 1,925 10-28-2019 19:39 4e839904 pust024_case_16.out 681,462 10-28-2019 23:51 d9556f7e pust024_case_17.inp 1,922 10-28-2019 19:39 397a4f1e pust024_case_17.out 680,550 10-29-2019 00:09 231988bd pust024_case_18.inp 1,925 10-28-2019 19:39 d538a792 pust024_case_18.out 681,224 10-29-2019 00:16 50389061 pust024_case_19.inp 1,925 10-28-2019 19:39 4fec1229 pust024_case_19.out 680,850 10-29-2019 00:16 8d53d774 pust024_case_20.inp 1,921 10-28-2019 19:39 337275f7 pust024_case_20.out 681,715 10-28-2019 23:58 7baea19a pust024_case_21.inp 1,920 10-28-2019 19:39 eb39be0b pust024_case_21.out 681,434 10-29-2019 00:18 1f8368cd pust024_case_22.inp 1,921 10-28-2019 19:39 8b9edde2 pust024_case_22.out 680,006 10-29-2019 00:12 08eaa07e pust024_case_23.inp 1,921 10-28-2019 19:39 e223385a pust024_case_23.out 681,742 10-29-2019 00:00 7ce17c11
\\Validation\\u233\\ (62) 20,454,594 11-25-2019 09:21 233st015_case_1.inp 593 10-31-2019 11:53 54a3a627 233st015_case_1.out 659,200 10-31-2019 12:23 5a7216ab 233st015_case_2.inp 597 10-31-2019 11:53 aa13e338 233st015_case_2.out 658,841 10-31-2019 12:31 12772c20 233st015_case_3.inp 617 10-31-2019 11:53 299e580b 233st015_case_3.out 660,887 10-31-2019 13:01 1641d719 233st015_case_4.inp 619 10-31-2019 11:53 92e6ac3f 233st015_case_4.out 660,887 10-31-2019 12:53 75795432 233st015_case_5.inp 597 10-31-2019 11:53 0baf2a5e 233st015_case_5.out 659,233 10-31-2019 12:29 e2718bf6 233st015_case_6.inp 600 10-31-2019 11:53 1f839b3a 233st015_case_6.out 659,618 10-31-2019 12:24 1dfa42ef 233st015_case_7.inp 601 10-31-2019 11:53 618790dc 233st015_case_7.out 659,044 10-31-2019 12:37 618575bc 233st015_case_8.inp 600 10-31-2019 11:53 4889e2c3 233st015_case_8.out 659,111 10-31-2019 12:27 24d043b0 233st015_case_9.inp 600 10-31-2019 11:53 cc6be208 233st015_case_9.out 659,845 10-31-2019 12:23 c067c18e 233st015_case_10.inp 603 10-31-2019 11:53 4d7fce92 233st015_case_10.out 659,227 10-31-2019 12:24 2be1230b 233st015_case_11.inp 597 10-31-2019 11:53 cdcdf326 233st015_case_11.out 658,788 10-31-2019 12:38 896d121e 233st015_case_12.inp 597 10-31-2019 11:53 ea22b2ab 233st015_case_12.out 659,261 10-31-2019 12:31 3d1ea4fc 233st015_case_13.inp 597 10-31-2019 11:53 d455a446 233st015_case_13.out 658,503 10-31-2019 12:30 8369220e 233st015_case_14.inp 619 10-31-2019 11:53 82c189f9 233st015_case_14.out 660,824 10-31-2019 13:04 338ff44a 233st015_case_15.inp 597 10-31-2019 11:53 82b81539 233st015_case_15.out 658,839 10-31-2019 12:31 329356c2 233st015_case_16.inp 600 10-31-2019 11:53 c064c9fc 233st015_case_16.out 659,023 10-31-2019 12:27 ff7ce09c 233st015_case_17.inp 600 10-31-2019 11:53 15042115 233st015_case_17.out 659,630 10-31-2019 12:40 764c46d2 233st015_case_18.inp 593 10-31-2019 11:53 07347fd6 233st015_case_18.out 659,112 10-31-2019 12:24 3a9ab66b 233st015_case_19.inp 600 10-31-2019 11:53 715b4e31 233st015_case_19.out 659,632 10-31-2019 12:27 f2d332b5 233st015_case_20.inp 597 10-31-2019 11:53 e266869e 233st015_case_20.out 659,289 10-31-2019 12:41 cc783e6b 233st015_case_21.inp 597 10-31-2019 11:53 60910b46 233st015_case_21.out 658,058 10-31-2019 12:33 e1d65fbb
Calculation Continuation Sheet
- 1. Document
Title:
Shielded Container Criticality Analysis
- 2. Document Number:
SCA-CAL-0001
- 3. Document Revision:
0
- 4. Page:
190 of 190 233st015_case_22.inp 597 10-31-2019 11:53 ad0fa25f 233st015_case_22.out 658,342 10-31-2019 12:35 0aa00173 233st015_case_23.inp 597 10-31-2019 11:53 a6f11fca 233st015_case_23.out 658,668 10-31-2019 12:32 c582af2f 233st015_case_24.inp 600 10-31-2019 11:53 2cbb7714 233st015_case_24.out 658,373 10-31-2019 12:31 a2a40f17 233st015_case_25.inp 604 10-31-2019 11:53 694e47c6 233st015_case_25.out 659,584 10-31-2019 12:57 1cf6e8c5 233st015_case_26.inp 597 10-31-2019 11:53 b508a7f6 233st015_case_26.out 658,917 10-31-2019 12:51 d351d520 233st015_case_27.inp 595 10-31-2019 11:53 8532dc3e 233st015_case_27.out 659,256 10-31-2019 12:40 047fee89 233st015_case_28.inp 600 10-31-2019 11:53 b17753dc 233st015_case_28.out 658,512 10-31-2019 12:39 e259c155 233st015_case_29.inp 600 10-31-2019 11:53 21e89b1f 233st015_case_29.out 659,213 10-31-2019 12:37 3c53a2c7 233st015_case_30.inp 600 10-31-2019 11:53 89546e82 233st015_case_30.out 659,026 10-31-2019 12:36 f2f4c63f 233st015_case_31.inp 600 10-31-2019 11:53 dc027d55 233st015_case_31.out 659,240 10-31-2019 12:35 746ce895
\\Validation\\Uslstats\\ (2) 24,410 11-25-2019 09:25 sc.inp 4,825 10-30-2019 21:47 3848069a sc.out 19,585 10-30-2019 21:47 196a8029