ML21048A324

From kanterella
Jump to navigation Jump to search

License Amendment Request for Application to Revise Technical Specifications to Adopt TSTF-205 -A Revision of Calibration, Channel Functional Test, and Related Definitions
ML21048A324
Person / Time
Site: Limerick  
(NPF-039, NPF-085)
Issue date: 02/17/2021
From: David Helker
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML21048A324 (15)


Text

([HORQ:D\\

.HQQHWW6TXDUH3$

ZZZH[HORQFRUSFRP

&)5

)HEUXDU\\ 

86 1XFOHDU5HJXODWRU\\&RPPLVVLRQ

$771'RFXPHQW&RQWURO'HVN

DVKLQJWRQ'&

/LPHULFN*HQHUDWLQJ6WDWLRQ8QLWVDQG

5HQHZHG)DFLOLW\\2SHUDWLQJ/LFHQVH1RV13)DQG13)

15&'RFNHW1RVDQG 

68%-(&7

/LFHQVH$PHQGPHQW5HTXHVWIRU $SSOLFDWLRQWR5HYLVH7HFKQLFDO6SHFLILFDWLRQV

WR$GRSW767)$³5HYLVLRQRI&DOLEUDWLRQ&KDQQHO)XQFWLRQDO7HVWDQG

5HODWHG'HILQLWLRQV'

3XUVXDQWWR&)5³$SSOLFDWLRQIRUDPHQGPHQWRIOLFHQVH FRQVWUXFWLRQSHUPLW RUHDUO\\

VLWHSHUPLW'([HORQ*HQHUDWLRQ&RPSDQ\\//& ([HORQ SURSRVHV FKDQJHVWRWKH7HFKQLFDO

6SHFLILFDWLRQV 76 $SSHQGL[$RI5HQHZHG)DFLOLW\\2SHUDWLQJ/LFHQVH1RV13)DQG13)

IRU/LPHULFN*HQHUDWLQJ6WDWLRQ /*6 8QLWVDQGUHVSHFWLYHO\\

7KHSURSRVHGDPHQGPHQWV ZRXOGUHYLVH/*676'HILQLWLRQVDQG IRU&+$11(/

&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67

UHVSHFWLYHO\\7KHSURSRVHGFKDQJHVZLOODOLJQWKH/*676GHILQLWLRQVZLWKWKHGHILQLWLRQVLQ

7HFKQLFDO6SHFLILFDWLRQ7DVN)RUFH 767) 7UDYHOHU$ 5HYLVLRQ ³5HYLVLRQRI&KDQQHO

&DOLEUDWLRQ&KDQQHO)XQFWLRQDO7HVWDQG5HODWHG'HILQLWLRQV' $GGLWLRQDOO\\/2*,&6<67(0

)81&7,21$/7(67 LVIXUWKHUUHYLVHGWR HOLPLQDWHWKHUHTXLUHPHQWRIWKHORJLFV\\VWHP

IXQFWLRQDOWHVWWRFRQWLQXH WKURXJKWRWKHDFWXDWLQJGHYLFHDWWKHHQGRIWKHORJLFFLUFXLW

VHTXHQFH

7KHSURSRVHG FKDQJHVDUH FRQVLVWHQW ZLWK185(* 5HYLVLRQ9ROXPH 6HFWLRQ

³'HILQLWLRQV'DQGWKHDVVRFLDWHGODQJXDJHIRU&+$11(/&$/,%5$7,21&+$11(/

)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67 'HYLDWLRQVIURPWKH

DSSURYHG76)7$GXHWR/*6QRWEHLQJDQLPSURYHG6WDQGDUG7HFKQLFDO6SHFLILFDWLRQ

QXFOHDUSRZHUSODQWDUHH[SODLQHGLQ$WWDFKPHQWRIWKLVGRFXPHQW

(YDOXDWLRQRIWKHSURSRVHGFKDQJHVLVSURYLGHGLQ$WWDFKPHQW 0DUNXSVRIWKHSURSRVHG76

FKDQJHVDUHSURYLGHGLQ$WWDFKPHQW

([HORQKDVFRQFOXGHGWKDWWKHSURSRVHGFKDQJHVSUHVHQWQRVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ

XQGHUWKHVWDQGDUGVVHWIRUWKLQ &)5³,VVXDQFHRIDPHQGPHQW'

/LFHQVH$PHQGPHQW5HTXHVW Application to Revise TS Definitions

'RFNHW1RVDQG

)HEUXDU\\

3DJH

7KHSURSRVHGFKDQJHVKDYHEHHQUHYLHZHGE\\WKH3ODQW2SHUDWLRQV5HYLHZ&RPPLWWHHLQ

DFFRUGDQFHZLWKWKHUHTXLUHPHQWVRIWKH([HORQ4XDOLW\\$VVXUDQFH3URJUDP

7KLVOLFHQVHDPHQGPHQWUHTXHVWFRQWDLQVQRUHJXODWRU\\FRPPLWPHQWV

([HORQUHTXHVWVDSSURYDORIWKHSURSRVHGDPHQGPHQWVE\\)HEUXDU\\ 8SRQ15&

DSSURYDOWKHDPHQGPHQWVVKDOOEHLPSOHPHQWHGZLWKLQGD\\VRILVVXDQFH

,QDFFRUGDQFHZLWK&)51RWLFHIRUSXEOLFFRPPHQW6WDWHFRQVXOWDWLRQSDUDJUDSK

E ([HORQLVQRWLI\\LQJWKH&RPPRQZHDOWKRI3HQQV\\OYDQLDRIWKLVDSSOLFDWLRQIRUOLFHQVH

DPHQGPHQWE\\WUDQVPLWWLQJDFRS\\RIWKLVOHWWHUDQGLWVDWWDFKPHQWVWRWKHGHVLJQDWHG6WDWH

2IILFLDO

,I\\RXKDYHDQ\\TXHVWLRQVRUUHTXLUHDGGLWLRQDOLQIRUPDWLRQSOHDVHFRQWDFW6WHYH)OLFNLQJHU DW



,GHFODUHXQGHUSHQDOW\\RISHUMXU\\WKDWWKHIRUHJRLQJLVWUXHDQGFRUUHFW([HFXWHGRQWKH WK GD\\RI)HEUXDU\\ 

5HVSHFWIXOO\\

'DYLG3+HONHU

6U0DQDJHU/LFHQVLQJ

([HORQ*HQHUDWLRQ&RPSDQ\\//&

$WWDFKPHQWV



(YDOXDWLRQRI3URSRVHG&KDQJHV



3URSRVHG7HFKQLFDO6SHFLILFDWLRQV0DUNXS3DJHV FF

8615&5HJLRQ,5HJLRQDO$GPLQLVWUDWRU ZDWWDFKPHQWV 8615&3URMHFW0DQDJHU/*6



8615&6HQLRU5HVLGHQW,QVSHFWRU/*6



'LUHFWRU%XUHDXRI5DGLDWLRQ3URWHFWLRQ 3HQQV\\OYDQLD'HSDUWPHQW RI(QYLURQPHQWDO3URWHFWLRQ



$77$&+0(17

/LFHQVH$PHQGPHQW5HTXHVW

/LPHULFN*HQHUDWLQJ6WDWLRQ8QLWVDQG

'RFNHW1RVDQG

(9$/8$7,212)352326('&+$1*(6 6XEMHFW

/LFHQVH$PHQGPHQW5HTXHVWIRU $SSOLFDWLRQWR5HYLVH7HFKQLFDO

6SHFLILFDWLRQVWR$GRSW767)$³5HYLVLRQRI&DOLEUDWLRQ&KDQQHO

)XQFWLRQDO7HVWDQG5HODWHG'HILQLWLRQV'



6800$5<'(6&5,37,21



'(7$,/(''(6&5,37,21



7(&+1,&$/(9$/8$7,21



5(*8/$725<(9$/8$7,21



$SSOLFDEOH5HJXODWRU\\5HTXLUHPHQWV&ULWHULD



3UHFHGHQW



1R6LJQLILFDQW+D]DUGV&RQVLGHUDWLRQ



&RQFOXVLRQV



(19,5210(17$/&216,'(5$7,21



5()(5(1&(6

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV



6800$5<'(6&5,37,21 3XUVXDQWWR&)5³$SSOLFDWLRQIRUDPHQGPHQWRIOLFHQVH FRQVWUXFWLRQSHUPLW RUHDUO\\

VLWHSHUPLW'([HORQ*HQHUDWLRQ&RPSDQ\\//& ([HORQ SURSRVHVFKDQJHVWRWKH7HFKQLFDO

6SHFLILFDWLRQV 76 $SSHQGL[$RI5HQHZHG)DFLOLW\\2SHUDWLQJ/LFHQVH1RV13)DQG13)

IRU/LPHULFN*HQHUDWLQJ6WDWLRQ /*6 8QLWVDQGUHVSHFWLYHO\\

7KHSURSRVHGDPHQGPHQWV ZRXOGUHYLVH/*676'HILQLWLRQVDQGIRU&+$11(/

&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67

UHVSHFWLYHO\\7KHSURSRVHGFKDQJHVZLOODOLJQWKH/*676GHILQLWLRQVZLWKWKHGHILQLWLRQVLQ

7HFKQLFDO6SHFLILFDWLRQ7DVN)RUFH 767) 7UDYHOHU$ 5HYLVLRQ³5HYLVLRQRI&KDQQHO

&DOLEUDWLRQ&KDQQHO)XQFWLRQDO 7HVWDQG5HODWHG'HILQLWLRQV'$GGLWLRQDOO\\/2*,&6<67(0

)81&7,21$/7(67 LVIXUWKHUUHYLVHGWR HOLPLQDWHWKHUHTXLUHPHQWRIWKHORJLFV\\VWHP

IXQFWLRQDOWHVWWRFRQWLQXH WKURXJKWRWKHDFWXDWLQJGHYLFHDWWKHHQGRIWKHORJLFFLUFXLW

VHTXHQFH

7KHSURSRVHG FKDQJHVDUH FRQVLVWHQW ZLWK185(* 5HYLVLRQ9ROXPH 6HFWLRQ

³'HILQLWLRQV'DQGWKHDVVRFLDWHGODQJXDJHIRU&+$11(/&$/,%5$7,21&+$11(/

)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67'HYLDWLRQVIURPWKHDSSURYHG

76)7$GXHWR/*6QRWEHLQJDQLPSURYHG6WDQGDUG7HFKQLFDO6SHFLILFDWLRQ 676 QXFOHDU

SRZHUSODQWDUHH[SODLQHGLQWKLVDWWDFKPHQW DVGHVFULEHGEHORZ



'(7$,/(''(6&5,37,21 7KHSURSRVHGDPHQGPHQWV ZRXOGUHYLVH/*676'HILQLWLRQVDQGIRU&+$11(/

&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67

UHVSHFWLYHO\\DVVKRZQEHORZ

7KH/*676&+$11(/&$/,%5$7,21GHILQLWLRQFKDQJHVDUHVKRZQEHORZ

$&+$11(/&$/,%5$7,21VKDOOEHWKHDGMXVWPHQWDVQHFHVVDU\\RIWKHFKDQQHORXWSXWVXFK

WKDWLWUHVSRQGVZLWKWKHQHFHVVDU\\UDQJHDQGDFFXUDF\\WRNQRZQYDOXHVRIWKHSDUDPHWHUZKLFK

WKHFKDQQHOPRQLWRUV7KH&+$11(/&$/,%5$7,21VKDOOHQFRPSDVVWKHHQWLUHFKDQQHO

LQFOXGLQJWKHVHQVRUDQGDODUPDQGRUWULSIXQFWLRQVDQGVKDOOLQFOXGHWKH DOOGHYLFHVLQWKH

FKDQQHOUHTXLUHGIRU23(5$%,/,7<DQG VKDOOLQFOXGH WKH&+$11(/)81&7,21$/7(677KH

&+$11(/&$/,%5$7,21PD\\EHSHUIRUPHGE\\DQ\\VHULHVRIVHTXHQWLDORYHUODSSLQJRUWRWDO

FKDQQHOVWHSV VXFKWKDWWKHHQWLUHFKDQQHOLVFDOLEUDWHG DQG HDFKVWHSPXVWEHSHUIRUPHGZLWKLQ

WKH)UHTXHQF\\LQWKH6XUYHLOODQFH)UHTXHQF\\&RQWURO3URJUDPIRUWKHGHYLFHVLQFOXGHGLQWKH

VWHS

7KH/*676 &+$11(/)81&7,21$/7(67 GHILQLWLRQFKDQJHVDUHVKRZQEHORZ

$&+$11(/)81&7,21$/7(67VKDOOEH

D

$QDORJFKDQQHOV WKHLQMHFWLRQRIDVLPXODWHGVLJQDOLQWRWKHFKDQQHODVFORVHWRWKHVHQVRU

DVSUDFWLFDEOHWRYHULI\\23(5$%,/,7<LQFOXGLQJDODUPDQGRUWULSIXQFWLRQVDQGFKDQQHO

IDLOXUHWULSV RIDOOGHYLFHVLQWKHFKDQQHOUHTXLUHGIRUFKDQQHO23(5$%,/,7<

E

%LVWDEOHFKDQQHOV WKHLQMHFWLRQRIDVLPXODWHGVLJQDOLQWRWKHVHQVRUWRYHULI\\23(5$%,/,7<

LQFOXGLQJDODUPDQGRUWULSIXQFWLRQV RIDOOGHYLFHVLQWKHFKDQQHOUHTXLUHGIRU23(5$%,/,7<

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV 7KH&+$11(/)81&7,21$/7(67PD\\EHSHUIRUPHGE\\DQ\\VHULHVRIVHTXHQWLDORYHUODSSLQJ

RUWRWDOFKDQQHOVWHSV VXFKWKDWWKHHQWLUHFKDQQHOLVWHVWHGDQGHDFKVWHSPXVWEHSHUIRUPHG

ZLWKLQWKH)UHTXHQF\\LQWKH6XUYHLOODQFH)UHTXHQF\\&RQWURO3URJUDPIRUWKHGHYLFHVLQFOXGHGLQ

WKHVWHS

7KH/*676/2*,&6<67(0)81&7,21$/7(67GHILQLWLRQFKDQJHVDUHVKRZQEHORZ

$/2*,&6<67(0)81&7,21$/7(67VKDOOEHDWHVWRIDOOORJLFFRPSRQHQWVLHDOO

UHOD\\VDQGFRQWDFWVDOOWULSXQLWVVROLGVWDWHORJLFHOHPHQWVHWF UHTXLUHGIRU

23(5$%,/,7<RIDORJLFFLUFXLWIURP DVFORVHWRWKH VHQVRUDVSUDFWLFDEOHXS WREXWQRW

LQFOXGLQJ WKURXJKDQGLQFOXGLQJ WKH DFWXDWHGGHYLFHWRYHULI\\23(5$%,/,7<7KH/2*,&

6<67(0)81&7,21$/7(67PD\\EHSHUIRUPHGE\\DQ\\VHULHVRIVHTXHQWLDO

RYHUODSSLQJRUWRWDOV\\VWHPVWHSVVXFKWKDWWKHHQWLUHORJLFV\\VWHPLVWHVWHG

7KHSURSRVHGDPHQGPHQWV ZRXOGUHYLVH/*676'HILQLWLRQVDQGIRU&+$11(/

&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG /2*,&6<67(0)81&7,21$/7(67 WR

DOLJQWKH/*676GHILQLWLRQVZLWKWKHGHILQLWLRQVDSSURYHGLQ767)$

$GGLWLRQDOO\\WKHSURSRVHGFKDQJHV HOLPLQDWHWKH UHTXLUHPHQWRIWKH/2*,&6<67(0

)81&7,21$/7(67 WR FRQWLQXH WKURXJKWRDFWXDWH WKHGHYLFHDWWKHHQGRIWKHORJLFFLUFXLW

VHTXHQFH7KHUHYLVHGGHILQLWLRQZLOOUHTXLUHWKHWHVWWRLQFOXGHDOOORJLFFRPSRQHQWVLQWKHFLUFXLW UHTXLUHGIRURSHUDELOLW\\ XSWREXWQRWLQFOXGLQJWKHDFWXDWHGGHYLFH

7KHSURSRVHG FKDQJHVDUH FRQVLVWHQW ZLWK185(* 5HYLVLRQ9ROXPH 6HFWLRQ

³'HILQLWLRQV'

/*68)6$5&KDSWHU ³,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV'LQFOXGHVWKURXJKUHIHUHQFHV

PXFKRIWKHOLFHQVLQJEDVLVIRU/*6¶VFXUUHQWSUDFWLFHVIRUFRQGXFWLQJ&+$11(/

&$/,%5$7,21 &+$11(/)81&7,21$/ 7(67 DQG /2*,&6<67(0)81&7,21$/7(67

8SRQLVVXDQFHRIOLFHQVHDPHQGPHQWV LQWKLVPDWWHUWKH8)6$5ZLOOEHXSGDWHGDVQHFHVVDU\\



7(&+1,&$/(9$/8$7,21



$SSOLFDELOLW\\RIWKH3XEOLVKHG6DIHW\\(YDOXDWLRQ 7KHSURSRVHGDPHQGPHQWV ZRXOGUHYLVH/*676'HILQLWLRQVDQGIRU&+$11(/

&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0)81&7,21$/7(67

UHVSHFWLYHO\\

7KHUHYLVHGGHILQLWLRQVHOLPLQDWHDFXUUHQWDPELJXLW\\DQGSRVVLEOHPLVLQWHUSUHWDWLRQRI

&+$11(/&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0

)81&7,21$/7(677KHFXUUHQWGHILQLWLRQVXVHSKUDVHVVLPLODUWRUHTXLUHGVHQVRUDODUP

LQWHUORFNGLVSOD\\DQGWULSIXQFWLRQV DQGUHTXLUHGUHOD\\VDQGFRQWDFWVWULSXQLWVVROLGVWDWH

ORJLFHOHPHQWVHWF 7KHUHLVDPELJXLW\\LQWKHDSSOLFDWLRQRIWKHZRUGUHTXLUHGDQGZKHWKHUWKH

OLVWLVLQFOXVLYHRUUHSUHVHQWDWLYH7KHUHIRUHWKLVOLVWKDVEHHQUHSODFHGZLWKSKUDVHVVLPLODUWR

DOOGHYLFHVLQWKHFKDQQHOUHTXLUHGIRUFKDQQHO23(5$%,/,7<7KLVFODULILHVWKHXVHRIWKH

ZRUGUHTXLUHGDQGPDNHVFOHDUWKDWWKHFRPSRQHQWVWKDWDUHUHTXLUHGWREHWHVWHGRU

FDOLEUDWHGDUHRQO\\WKRVHWKDWDUHQHFHVVDU\\IRUWKHFKDQQHOWRSHUIRUPLWVVDIHW\\IXQFWLRQ7KH

OLVWRIFRPSRQHQWVLVHOLPLQDWHGIURPWKHGHILQLWLRQ7KHVHFKDQJHVZLOOFODULI\\WKHUHTXLUHPHQWV

DQGDOORZIRUFRQVLVWHQWDSSOLFDWLRQRIWKHGHILQLWLRQVWHVWVDQGFDOLEUDWLRQV

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV

,QDGGLWLRQLQWKHVWDWHPHQWDGGUHVVLQJWKHDOORZDQFHWRKDYHWKHWHVWSHUIRUPHGE\\PHDQV

RIDQ\\VHULHVRIVHTXHQWLDORYHUODSSLQJRUWRWDOFKDQQHOVWHSVWKHVWDWHPHQWVXFK WKDW WKHHQWLUHFKDQQHOUHOD\\LVWHVWHGFDOLEUDWHG<<LVGHOHWHG7KLVGHOHWLRQLVSXUHO\\WRUHPRYHWKH

FRQIOLFWEHWZHHQWKHYHUEDWLPUHDGLQJRIWKHGHILQLWLRQZKHUHLWLVVWDWHGRIDOOGHYLFHVLQWKH

FKDQQHOUHTXLUHGIRUFKDQQHO23(5$%,/,7<

7KHUHYLVHG&+$11(/)81&7,21$/7(67GHILQLWLRQGRHVQRWDGGUHVVWKHPHWKRGRIWKH

WHVWLQJRIDOORIWKHUHTXLUHGFKDQQHOGHYLFHV$ VXFFHVVIXOWHVWRIDFKDQQHOUHOD\\DQG

DVVRFLDWHGUHTXLUHGFRQWDFWVPD\\EHWKHYHULILFDWLRQRIDVLQJOHFRQWDFWDQGWKDWDOOFRQWDFWVRI

WKHUHTXLUHGGHYLFHQHHGQRWEHWHVWHGSURYLGHGWKHUHTXLUHGFKDQQHOFRQWDFWLVRWKHUZLVH

WHVWHG

7KHVH FKDQJHV DUH FRQVLVWHQWZLWKWKHLPSURYHG676GHILQLWLRQLQ185(*5HYLVLRQ

DQG DUH WKHUHIRUHDFFHSWDEOH



'HYLDWLRQVIURPWKH3XEOLVKHG767)$

&XUUHQWO\\D /2*,&6<67(0)81&7,21$/7(67 VKDOOEHDWHVWRIDOOORJLFFRPSRQHQWVLH

DOOUHOD\\VDQGFRQWDFWVDOOWULSXQLWVVROLGVWDWHORJLFHOHPHQWVHWFRIDORJLFFLUFXLWIURP

VHQVRUWKURXJKDQGLQFOXGLQJWKHDFWXDWHGGHYLFHWRYHULI\\23(5$%,/,7<7KH/2*,&

6<67(0)81&7,21$/7(67 PD\\EHSHUIRUPHGE\\DQ\\VHULHVRIVHTXHQWLDORYHUODSSLQJ RU

WRWDOV\\VWHPVWHSVVXFKWKDWWKHHQWLUHORJLFV\\VWHPLVWHVWHG $ /2*,&6<67(0)81&7,21$/

7(67 LV FRQGXFWHGDVD6XUYHLOODQFH5HTXLUHPHQW 65 ZLWKLQ76

,QDGGLWLRQWRFODULI\\LQJWKHWHVWLQJRIFRPSRQHQWVUHTXLUHGIRU23(5$%,/,7<WKHSURSRVHG

FKDQJH HOLPLQDWHVWKHUHTXLUHPHQWRID /2*,&6<67(0)81&7,21$/7(67 WR FRQWLQXH WKURXJKWRDFWXDWH WKHGHYLFHDWWKHHQGRIWKHORJLFFLUFXLWVHTXHQFH7KHFXUUHQWGHILQLWLRQRI

/2*,&6<67(0)81&7,21$/7(67 VWDWHVWKDWWKHDFWLRQZLOOJRWRFRPSOHWLRQHJ SXPSV

ZLOOEHVWDUWHGDQGYDOYHVRSHUDWHG7KHUHYLVHGGHILQLWLRQZLOOVWLOOUHTXLUHWKHWHVWWRLQFOXGHDOO

ORJLFFRPSRQHQWVLQWKHFLUFXLWXSWREXWQRWLQFOXGLQJWKHDFWXDWHGGHYLFH&RPSOHWLRQRIWKH ORJLFFLUFXLWZLOOEHUHTXLUHGIRUWKHWHVWWREHFRQFOXGHGDVVDWLVIDFWRU\\7KLVQDUURZVWKH /2*,&

6<67(0)81&7,21$/7(67 IRFXVRQWKHORJLFFLUFXLWDVWKHFULWHULDRIWHVWLQJQRWLQFOXGLQJ

WKH DFWXDWHGGHYLFH ZKLFKLVWHVWHGVHSDUDWHO\\ XQGHURWKHUWHVWLQJUHTXLUHPHQWHJLQVHUYLFH

WHVWLQJHWF )XUWKHUPRUHE\\QRWDFWXDWLQJWKHGHYLFH LWOHVVHQVXQQHFHVVDU\\ZHDURQWKH

DFWXDWLQJGHYLFHSURORQJLQJWKHOLIHRIWKHGHYLFHDQGORZHULQJWKHSUREDELOLW\\RIXQZDQWHG

WUDQVLHQWVWRWKHSODQW

7KHSURSRVHGFKDQJHWRWKHGHILQLWLRQRID/2*,&6<67(0)81&7,21$/7(67 DQGH[SOLFLW

H[FOXVLRQRIDQ\\UHTXLUHPHQWWRWHVWWKHDFWXDWHGGHYLFHLVFRQVLVWHQWZLWKFXUUHQWLQGXVWU\\

VWDQGDUGV 5HIHUHQFH DQG FODULILHVWKHGHILQLWLRQVRWKDWWKHWHVWLQJUHTXLUHPHQWLVPRUH

FOHDUO\\XQGHUVWRRG 7KHUHYLVHGGHILQLWLRQGRHVQRWQHFHVVDULO\\UHTXLUHWHVWLQJRIWKHVHQVRURU

DFWXDWHGGHYLFHDVSDUWRIWKH/2*,&6<67(0)81&7,21$/7(67+RZHYHUH[LVWLQJ

UHTXLUHPHQWVIRUWKHWHVWLQJRIVHQVRUVDQGDFWXDWHGGHYLFHVDVSDUWRIFKDQQHOFDOLEUDWLRQVDQG

LQVHUYLFHWHVWV ,67V DUHXQFKDQJHGDQGDUHDGHTXDWHWRYHULI\\RSHUDELOLW\\RIWKRVH

FRPSRQHQWVRUGHYLFHV HJ SXPSVDQGYDOYHV 

$ /2*,&6<67(0)81&7,21$/7(67 LVD FRPSOH[VXUYHLOODQFHZKLFKPD\\UHTXLUHQXPHURXV

WHPSRUDU\\DOWHUDWLRQVDQGFRPSOLFDWHGDGPLQLVWUDWLYHFRQWUROV7KHFRPSOH[LW\\RIWKHVXUYHLOODQFH

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV WHVWVKDVDVLJQLILFDQWSRWHQWLDOIRUXQGHVLUHGDFWXDWLRQVDQG2SHUDWRUHUURUZKLFKFDQLQGXFH

XQGHVLUDEOHSODQWWUDQVLHQWV

7HVWLQJLQVWUXPHQWFKDQQHOVDQGORJLFFLUFXLWVVHSDUDWHIURPWKHLUDFWXDWHGGHYLFHVLV

DFFHSWDEOHLQGXVWU\\SUDFWLFH$FWXDWHGGHYLFHV HJSXPSVDQGYDOYHV DUHVXEMHFWWR,67

UHTXLUHPHQWVDQGWKHFRPELQHGWHVWLQJRIWKHYDULRXVFRPSRQHQWVDQGORJLFV\\VWHPVYHULI\\WKH

RSHUDELOLW\\RIWKHHQWLUHV\\VWHP

/RJLFV\\VWHPVDUHFRPSULVHGRIGHWHFWLRQGHYLFHVDFWLYDWHGE\\FHUWDLQSK\\VLFDOFRQGLWLRQV HJ

SUHVVXUHVZLWFKHVWHPSHUDWXUHVZLWFKHVHWF DQGGHFLVLRQPDNLQJUHOD\\QHWZRUNVWKDWZLOO

FDXVHDVDIHW\\V\\VWHPFRPSRQHQWRUGHYLFH HJSXPSYDOYHHWF WRRSHUDWHZKHQQHHGHG

(DFKUHOD\\LQDGHFLVLRQPDNLQJORJLFQHWZRUNKDVRQHRUPRUHFRQWDFWSDLUVDVVRFLDWHGZLWKLW$

/2*,&6<67(0)81&7,21$/7(67 LQFOXGHVDOOORJLFFRPSRQHQWV LQFOXGLQJUHOD\\VDQG

FRQWDFWV LQWKHVHGHFLVLRQPDNLQJQHWZRUNVWRDVVXUHWKDWWKHV\\VWHPZLOORSHUDWHDVGHVLJQHG

XSRQGHPDQG

/2*,&6<67(0)81&7,21$/7(67 VKRXOGWHVWIRURSHUDELOLW\\RIDOOUHOD\\VFRQWDFWVWULSXQLWV

DQGVROLGVWDWHORJLFHOHPHQWVIURPDVFORVHWRWKHVHQVRUDVSUDFWLFDEOHXSWREXWQHHGQRW

LQFOXGHWKHDFWXDWHGGHYLFH$/2*,&6<67(0)81&7,21$/7(67 PD\\FRQVLVWRIDVLQJOH

LQWHJUDWHGWHVWEXWPD\\DOVREHSHUIRUPHGDVDVHULHVRIWHVWVSURYLGHGWKDWZKHQFRPELQHG

WKHHQWLUHORJLFV\\VWHPLVWHVWHG7R HQVXUHWKDWQRSDUWRIWKHORJLFLVRYHUORRNHGWKHSURFHGXUHV

IRUWKHVHSDUWLDOIXQFWLRQDOWHVWVHQVXUHWKDWDQRYHUODSRFFXUVEHWZHHQZKHUHRQHVHFWLRQRI

WHVWLQJHQGVDQGWKHQH[WVHFWLRQEHJLQV

767)$DOVRDGGVWZRSDUDJUDSKVWRWKH76%DVHVVHFWLRQIRU76,QVWUXPHQWDWLRQ7KH

SDUDJUDSKVSURYLGHDGGHGFODULI\\LQJLQIRUPDWLRQIRUZKDWLVDQDFFHSWDEOH&+$11(/

)81&7,21$/7(67RIDUHOD\\ XQGHUWKH6XUYHLOODQFH5HTXLUHPHQWV 65 7KH FODULI\\LQJ

ZRUGLQJLVDGGHGWRWKH%DVHVRIVHYHUDO,QVWUXPHQWDWLRQV\\VWHP657KLVLVGRQHEHFDXVH

LPSURYHG676SODQWVKDYH%DVHVIRUWKHLU65V/LPHULFNLVQRWDQLPSURYHG676SODQWGRHVQRW

KDYHLQIRUPDWLRQLQWKHLU76%DVHVIRU65VDQGWKHUHIRUHWKH767)$76%DVHVLQVHUWVGR

QRWDSSO\\WR/LPHULFN



5(*8/$725<(9$/8$7,21



$SSOLFDEOH5HJXODWRU\\5HTXLUHPHQWV&ULWHULD

,QDFFRUGDQFHZLWK&)5$SSOLFDWLRQIRUDPHQGPHQWRIOLFHQVHFRQVWUXFWLRQ SHUPLWRUHDUO\\VLWHSHUPLW([HORQ*HQHUDWLRQ&RPSDQ\\//& ([HORQ SURSRVHV FKDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV 76 $SSHQGL[$RIWKH5HQHZHG)DFLOLW\\

2SHUDWLQJ/LFHQVH1RV13)DQG13)IRU/LPHULFN*HQHUDWLQJ6WDWLRQ /*6 

8QLWVDQGUHVSHFWLYHO\\

7KH /*6 76FRQWDLQGHILQLWLRQVRIWHUPVXVHGWKURXJKRXWWKH767KHVHLQFOXGH GHILQLWLRQVRI

&+$11(/&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG/2*,&6<67(0

)81&7,21$/7(677KHVHGHILQLWLRQVSURYLGHEDVLFLQIRUPDWLRQDERXWZKDWWKHWHVW LQYROYHV

WKHFRPSRQHQWV HQFRPSDVVHGLQWKHWHVWDQGJHQHUDOLQIRUPDWLRQUHJDUGLQJ KRZWKHWHVWLVWR EHSHUIRUPHG

7KHSURSRVHGUHYLVLRQVDUHEDVHGRQWKH15&DSSURYHG7HFKQLFDO6SHFLILFDWLRQ 7DVN)RUFH

7UDYHOHU767)$5HYLVLRQ5HYLVLRQRI&KDQQHO&DOLEUDWLRQ &KDQQHO)XQFWLRQDO7HVW

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV DQG5HODWHG'HILQLWLRQV$VGLVFXVVHGLQ767)$ 5HYLVLRQWKHUHYLVLRQVHOLPLQDWH

DPELJXLW\\DQGSRVVLEOHPLVLQWHUSUHWDWLRQRIWKH GHILQLWLRQVDQGDUHQRWLQWHQGHGWRFKDQJHWKH

PHDQLQJRULQWHQWRIWKHDIIHFWHG GHILQLWLRQV

7KHSURSRVHGFKDQJHV DOVRHOLPLQDWHWKHUHTXLUHPHQWRIWKHORJLFV\\VWHPIXQFWLRQDOWHVWWR

FRQWLQXH WKURXJKWRDFWXDWLQJWKHGHYLFHDWWKHHQGRIWKHORJLFFLUFXLWVHTXHQFH7KHUHYLVHG

GHILQLWLRQZLOOUHTXLUHWKHWHVWWRLQFOXGHDOOORJLFFRPSRQHQWVLQWKHFLUFXLWXSWREXWQRW

LQFOXGLQJWKHDFWXDWHGGHYLFH

7KHSURSRVHGFKDQJHVFRQIRUPWRWKHUHTXLUHPHQWVRI&)5³7HFKQLFDO VSHFLILFDWLRQV'IRUWKHFRQWHQWVRI76DQGDUHFRQVLVWHQWZLWKWKH,PSURYHG6WDQGDUG 7HFKQLFDO6SHFLILFDWLRQVLVVXHGE\\WKH15&LQ185(*³6WDQGDUG7HFKQLFDO 6SHFLILFDWLRQV+/- *HQHUDO(OHFWULF%:53ODQWV' 7KHGHILQLWLRQVHFWLRQRIWKH76KDVKLVWRULFDOO\\

EHHQSURYLGHGWRKHOSPDLQWDLQFRQVLVWHQF\\ZLWKLQWKH76DVZHOODVZLWKLQGXVWU\\SUDFWLFHV

5HIHUHQFH 7KHUHTXLUHPHQWVRI&)5GRQRWUHTXLUHDGHILQLWLRQVHFWLRQLQWKH 76

([HORQKDVHYDOXDWHGWKHSURSRVHGFKDQJHVXVLQJWKHFULWHULDLQ&)5

³,VVXDQFHRIDPHQGPHQW'DQGKDVGHWHUPLQHGWKDWWKHSURSRVHGFKDQJHVGRQRWLQYROYH DVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ7KHIROORZLQJLQIRUPDWLRQLVSURYLGHGWRVXSSRUWD ILQGLQJRIQRVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ



3UHFHGHQW 7KHSURSRVHGFKDQJHVWR76'HILQLWLRQVDQG DUHVLPLODUWRFKDQJHVSUHYLRXVO\\

DSSURYHGE\\WKH15&VKRZQEHORZ

15&/HWWHUWR&RRSHU1XFOHDU6WDWLRQ³&RRSHU1XFOHDU6WDWLRQ+/-,VVXDQFHRI

$PHQGPHQW5(5HYLVH7HFKQLFDO6SHFLILFDWLRQV,QVWUXPHQWDWLRQ'HILQLWLRQV 7$&1R

0& '0DUFK $'$06$FFHVVLRQ1R0/  5HIHUHQFH 

15&/HWWHUWR9HUPRQW<DQNHH1XFOHDU3RZHU6WDWLRQ³9HUPRQW<DQNHH1XFOHDU3RZHU

6WDWLRQ+/-,VVXDQFHRI$PHQGPHQW5(/RJLF6\\VWHP)XQFWLRQDO7HVW 7$&1R

0% ''HFHPEHU $'$06$FFHVVLRQ1R0/  5HIHUHQFH 



1R6LJQLILFDQW+D]DUGV&RQVLGHUDWLRQ



'RWKHSURSRVHGFKDQJHVLQYROYHDVLJQLILFDQWLQFUHDVHLQWKHSUREDELOLW\\RU

FRQVHTXHQFHVRIDQDFFLGHQWSUHYLRXVO\\HYDOXDWHG" 5HVSRQVH1R

7KHGHILQLWLRQVRI&+$11(/&$/,%5$7,21&+$11(/)81&7,21$/ 7(67DQG

/2*,&6<67(0)81&7,21$/7(67 VSHFLILHGLQ76SURYLGHEDVLF LQIRUPDWLRQ

UHJDUGLQJZKDWWKHWHVWLQYROYHVWKHFRPSRQHQWVLQYROYHGLQWKHWHVW DQGJHQHUDO

LQIRUPDWLRQUHJDUGLQJKRZWKHWHVWLVWREHSHUIRUPHG7KHVH GHILQLWLRQVDQGWKHLU

VSHFLILF ZRUGLQJDUHQRWSUHFXUVRUVWRDQ\\DFFLGHQW$VD UHVXOW WKHVHUHYLVHGGHILQLWLRQV

UHVXOWLQQRLQFUHDVHLQWKHSUREDELOLW\\RUFRQVHTXHQFHVRIDQ DFFLGHQWSUHYLRXVO\\

HYDOXDWHG

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV 7KHSURSRVHGUHYLVLRQVRIWKHVHGHILQLWLRQVLQYROYHQRFKDQJHVWRSODQWGHVLJQ

HTXLSPHQWRURSHUDWLRQUHODWHGWRPLWLJDWLRQRIDFFLGHQWV7KHSURSRVHG UHYLVLRQVRI

WKHVHGHILQLWLRQVGRQRWFKDQJHWKHLUPHDQLQJRULQWHQW7KH SURSRVHGUHYLVLRQVFODULI\\

WKHGHILQLWLRQVDQGGRQRWUHVXOWLQDUHGXFWLRQRI UHTXLUHGWHVWLQJRILQVWUXPHQWDWLRQXVHG

WRPLWLJDWHDFFLGHQWV

7KHUHYLVHG/2*,&6<67(0)81&7,21$/7(67 GHILQLWLRQZLOOVWLOOUHTXLUHWKHWHVWWR

LQFOXGHDOOORJLFFRPSRQHQWVLQWKHFLUFXLWXSWREXWQRWLQFOXGLQJWKHDFWXDWHGGHYLFH

&RPSOHWLRQRIWKHORJLFFLUFXLWZLOOEHUHTXLUHGIRUWKHWHVWWREHFRQFOXGHGDV

VDWLVIDFWRU\\&RPELQHGWHVWLQJRIWKHYDULRXVFRPSRQHQWVDQGORJLFV\\VWHPVYHULI\\WKH

RSHUDELOLW\\RIWKHHQWLUHV\\VWHP DQGFHUWDLQDFWXDWHGGHYLFHV HJSXPSVDQGYDOYHV 

DUHDOVRVXEMHFWWR,67UHTXLUHPHQWV

7KHUHIRUHWKHSURSRVHGFKDQJHVGRQRWLQYROYHDVLJQLILFDQWLQFUHDVHLQWKHSUREDELOLW\\

RUFRQVHTXHQFHVRIDQDFFLGHQWSUHYLRXVO\\HYDOXDWHG



'RWKHSURSRVHGFKDQJHVFUHDWHWKHSRVVLELOLW\\RIDQHZRUGLIIHUHQWNLQGRI

DFFLGHQWIURPDQ\\DFFLGHQWSUHYLRXVO\\HYDOXDWHG" 5HVSRQVH1R

7KHSURSRVHGUHYLVLRQVRIWKHGHILQLWLRQVGRQRWLQYROYHDFKDQJHWRWKHGHVLJQRU RSHUDWLRQRIDQ\\SODQWVWUXFWXUHV\\VWHPRUFRPSRQHQW 66& $VDUHVXOWWKH SODQWZLOO

FRQWLQXHWREHRSHUDWHGLQWKHVDPHPDQQHU7KHSURSRVHGUHYLVLRQV ZLOOQRWUHVXOWLQD

FKDQJHWRKRZWKHLQVWUXPHQWDWLRQXVHGWRPRQLWRUSODQW RSHUDWLRQDQGWRPLWLJDWH

DFFLGHQWVLVWHVWHG2SHUDWLQJWKHSODQWDQGWHVWLQJWKH SODQW VLQVWUXPHQWDWLRQLQWKH

VDPHPDQQHUDVLVFXUUHQWO\\GRQH ZLOOQRWFUHDWH WKHSRVVLELOLW\\RIDQHZRUGLIIHUHQWNLQG

RIDFFLGHQW

$OVRWKHUHYLVHG/2*,&6<67(0)81&7,21$/7(67 GHILQLWLRQZLOOVWLOOUHTXLUHWKH

WHVWWRLQFOXGHDOOORJLFFRPSRQHQWVLQWKHFLUFXLWXSWREXWQRWLQFOXGLQJWKHDFWXDWHG

GHYLFH7KHFKDQJHVGRQRWDOWHUDVVXPSWLRQVPDGHLQWKHVDIHW\\DQDO\\VLV7KH

SURSRVHGFKDQJHVDUHFRQVLVWHQWZLWKFXUUHQWLQGXVWU\\VWDQGDUGV 5HIHUHQFH DQG

SODQWRSHUDWLQJSUDFWLFHV

7KHUHIRUHWKHSURSRVHGFKDQJHVGRQRWFUHDWHWKHSRVVLELOLW\\RIDQHZRUGLIIHUHQWNLQG

RIDFFLGHQWIURPDQ\\SUHYLRXVO\\HYDOXDWHG



'RWKHSURSRVHGFKDQJHVLQYROYHDVLJQLILFDQWUHGXFWLRQLQDPDUJLQRIVDIHW\\"

5HVSRQVH1R

7KHDIIHFWHGGHILQLWLRQVLQYROYHWHVWLQJRILQVWUXPHQWDWLRQXVHGLQWKHPLWLJDWLRQ RI DFFLGHQWVWRHQVXUHWKDWWKHLQVWUXPHQWDWLRQZLOOSHUIRUPDVDVVXPHGLQVDIHW\\ DQDO\\VHV

7KHSURSRVHGUHYLVLRQVRIWKHVHGHILQLWLRQVZLOOQRWFKDQJHWKHLU PHDQLQJRULQWHQW$VD

UHVXOWWKHLQVWUXPHQWDWLRQZLOOFRQWLQXHWREHWHVWHGLQ WKHVDPHPDQQHUDVLVFXUUHQWO\\

GRQH5HYLVLQJWKHVHGHILQLWLRQVDVSURSRVHG ZLOOQRWUHVXOWLQDFKDQJHWRWKHGHVLJQRU

RSHUDWLRQRIDQ\\SODQW66&XVHGWR VKXWGRZQ WKHSODQWLQLWLDWHWKH(PHUJHQF\\&RUH

&RROLQJ6\\VWHPVRULVRODWH SULPDU\\RUVHFRQGDU\\FRQWDLQPHQW$VDUHVXOWWKHDELOLW\\RI

WKHSODQWWRUHVSRQG WRDQGPLWLJDWHDFFLGHQWVLVXQFKDQJHGE\\WKHUHYLVHGGHILQLWLRQV

/LFHQVH$PHQGPHQW5HTXHVW

$WWDFKPHQW

$SSOLFDWLRQWR 5HYLVH 76'HILQLWLRQV 3DJH RI 

'RFNHW1RVDQG

(YDOXDWLRQRI3URSRVHG&KDQJHV 7KHUHYLVHG/2*,&6<67(0)81&7,21$/7(67 GHILQLWLRQZLOOVWLOOUHTXLUHWKHWHVWWR

LQFOXGHDOOORJLFFRPSRQHQWVLQWKHFLUFXLWXSWREXWQRWLQFOXGLQJWKHDFWXDWHGGHYLFH

&RPSOHWLRQRIWKHORJLFFLUFXLWZLOOEHUHTXLUHGIRUWKHWHVWWREHFRQFOXGHGDV

VDWLVIDFWRU\\&RPELQHGWHVWLQJRIWKHYDULRXVFRPSRQHQWVDQGORJLFV\\VWHPVYHULI\\WKH

RSHUDELOLW\\RIWKHHQWLUHV\\VWHP DQGFHUWDLQDFWXDWHGGHYLFHV HJSXPSVDQGYDOYHV 

DUHDOVRVXEMHFWWR,67UHTXLUHPHQWV

7KHUHIRUHWKHSURSRVHGFKDQJHVGRQRWLQYROYHDVLJQLILFDQWUHGXFWLRQLQDPDUJLQ RI VDIHW\\



&RQFOXVLRQV

%DVHGRQWKHDERYH([HORQFRQFOXGHVWKDWWKHSURSRVHGDPHQGPHQWV SUHVHQW QRVLJQLILFDQW

KD]DUGVFRQVLGHUDWLRQXQGHUWKHVWDQGDUGVVHWIRUWKLQ&)5 F DQGDFFRUGLQJO\\D

ILQGLQJRIQRVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQLVMXVWLILHG



(19,5210(17$/&216,'(5$7,21

$UHYLHZKDVGHWHUPLQHGWKDWWKHSURSRVHGFKDQJHV ZRXOGQRWFKDQJHDUHTXLUHPHQWZLWK

UHVSHFWWRLQVWDOODWLRQRUXVHRIDIDFLOLW\\FRPSRQHQWORFDWHGZLWKLQWKHUHVWULFWHGDUHDDVGHILQHG

LQ&)5DQGZRXOGQRWFKDQJHDQLQVSHFWLRQRUVXUYHLOODQFHUHTXLUHPHQW)XUWKHUPRUH

WKHSURSRVHGFKDQJHV GRQRWLQYROYH L DVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ LL DVLJQLILFDQW FKDQJHLQWKHW\\SHVRUVLJQLILFDQWLQFUHDVHLQWKHDPRXQWVRIDQ\\HIIOXHQWWKDWPD\\EHUHOHDVHG

RIIVLWHRU LLL DVLJQLILFDQWLQFUHDVHLQLQGLYLGXDORUFXPXODWLYHRFFXSDWLRQDOUDGLDWLRQH[SRVXUH

$FFRUGLQJO\\WKHSURSRVHGFKDQJHV PHHW WKHHOLJLELOLW\\FULWHULRQIRUFDWHJRULFDOH[FOXVLRQVHW

IRUWKLQ&)5 F  7KHUHIRUHSXUVXDQWWR&)5 E QRHQYLURQPHQWDOLPSDFW

VWDWHPHQWRUHQYLURQPHQWDODVVHVVPHQWQHHGEHSUHSDUHGLQFRQQHFWLRQZLWKWKHSURSRVHG

FKDQJHV



5()(5(1&(6



185(*³6WDQGDUG7HFKQLFDO6SHFLILFDWLRQV'5HYLVLRQ$SULO $'$06

$FFHVVLRQ1R0/$



767)$5HYLVLRQ³5HYLVLRQRI&DOLEUDWLRQ&KDQQHO)XQFWLRQDO7HVW DQG 5HODWHG'HILQLWLRQV'GDWHG-XO\\



 ³,(((6WDQGDUGIRU&ULWHULDIRUWKH3HULRGLF6XUYHLOODQFH7HVWLQJRI

1XFOHDU3RZHU*HQHUDWLQJ6WDWLRQ6DIHW\\'6HFWLRQ



15&/HWWHUWR&RRSHU1XFOHDU6WDWLRQ³&RRSHU1XFOHDU6WDWLRQ+/-,VVXDQFHRI

$PHQGPHQW5(5HYLVH7HFKQLFDO6SHFLILFDWLRQV,QVWUXPHQWDWLRQ'HILQLWLRQV 7$&

1R0& '0DUFK $'$06$FFHVVLRQ1R0/ 



15&/HWWHUWR9HUPRQW<DQNHH1XFOHDU3RZHU6WDWLRQ³9HUPRQW<DQNHH1XFOHDU

3RZHU6WDWLRQ+/-,VVXDQFHRI$PHQGPHQW 5(/RJLF6\\VWHP)XQFWLRQDO7HVW 7$&

1R0% ''HFHPEHU $'$06$FFHVVLRQ1R0/ 

$77$&+0(17

/LFHQVH$PHQGPHQW5HTXHVW

/LPHULFN*HQHUDWLQJ6WDWLRQ8QLWVDQG

'RFNHW1RVDQG

3URSRVHG7HFKQLFDO6SHFLILFDWLRQV0DUNXS3DJHV 8QLW763DJHV





8QLW763DJHV





1.0 DEFINITIONS The following terms are defined so that uniform interpretation of these specifications may be achieved. The defined terms appear in capitalized type and shall be applicable throughout these Technical Specifications.

ACTION 1.1 ACTION shall be that part of a Specification which prescribes remedial measures required under designated conditions.

AVERAGE PLANAR EXPOSURE 1.2 The AVERAGE PLANAR EXPOSURE shall be applicable to a specific planar height and is equal to the sum of the exposure of all the fuel rods in the specified bundle at the specified height divided by the number of fuel rods in the fuel bundle.

AVERAGE PLANAR LINEAR HEAT GENERATION RATE 1.3 The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) shall be applicable to a specific planar height and is equal to the sum of the LINEAR HEAT GENERATION RATES for all the fuel rods in the specified bundle at the specified height divided by the number of fuel rods in the fuel bundle.

CHANNEL CALIBRATION 1.4 A CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel output such that it responds with the necessary range and accuracy to known values of the parameter which the channel monitors. The CHANNEL CALIBRATION shall encompass the entire channel including the sensor and alarm and/or trip functions, and shall include the DOOWKHGHYLFHVLQWKHFKDQQHO

UHTXLUHGIRU23(5$%,/,7<DQGVKDOOLQFOXGHWKHCHANNEL FUNCTIONAL TEST. The CHANNEL CALIBRATION may be performed by any series of sequential, overlapping or total channel steps such that the entire channel is calibrated, and each step must be performed within the Frequency in the Surveillance Frequency Control Program for the devices included in the step.

CHANNEL CHECK 1.5 A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. This determination shall include, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrument channels measuring the same parameter.

CHANNEL FUNCTIONAL TEST 1.6 A CHANNEL FUNCTIONAL TEST shall be:

a.

Analog channels - the injection of a simulated signal into the channel

as close to the sensor as practicable to verify OPERABILITY including

alarm and/or trip functions and channel failure trips.RIDOOGHYLFHV

LQWKHFKDQQHOUHTXLUHGIRUFKDQQHO23(5$%,/,7<

b.

Bistable channels - the injection of a simulated signal into the sensor to verify OPERABILITY including alarm and/or trip functions.RIDOO GHYLFHVLQWKHFKDQQHOUHTXLUHGIRU23(5$%,/,7<

The CHANNEL FUNCTIONAL TEST may be performed by any series of sequential, overlapping or total channel steps such that the entire channel is tested, and each step must be performed within the Frequency in the Surveillance Frequency Control Program for the devices included in the step.

LIMERICK - UNIT 1 1-1 Amendment No. 243

DEFINITIONS LOGIC SYSTEM FUNCTIONAL TEST 1.20 A LOGIC SYSTEM FUNCTIONAL TEST shall be a test of all logic components, i.e., all relays and contacts, all trip units, solid state logic elements, etc, UHTXLUHGIRU23(5$%,/,7<of a logic circuit, from DVFORVHWRWKH

sensor DVSUDFWLFDOXSWREXWQRWLQFOXGLQJthrough and including the actuated device, to verify OPERABILITY. The LOGIC SYSTEM FUNCTIONAL TEST may be performed by any series of sequential, overlapping or total system steps such that the entire logic system is tested.

LOW (POWER) TRIP SETPOINT (LTSP) 1.20a The low power trip setpoint associated with the Rod Block Monitor (RBM) rod block trip setting applicable between 30% and 65% reactor thermal power.

1.21 (Deleted)

MEMBER(S) OF THE PUBLIC 1.22 MEMBER OF THE PUBLIC means any individual except when that individual is receiving an occupational dose.

MAPFAC(F)-(MAPLHGR FLOW FACTOR) 1.22a A core flow dependent multiplication factor used to flow bias the standard Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) limit.

MAPFAC(P)-(POWER DEPENDENT MAPLHGR MULTIPLIER) 1.22b A core power dependent multiplication factor used to power bias the standard Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) limit.

MINIMUM CRITICAL POWER RATIO (MCPR) 1.23 The MINIMUM CRITICAL POWER RATIO (MCPR) shall be the smallest CPR which exists in the core (for each class of fuel). Associated with the minimum critical power ratio is a core flow dependent (MCPR(F)) and core power dependent (MCPR(P)) minimum critical power ratio.

OFFSITE DOSE CALCULATION MANUAL 1.24 The OFFSITE DOSE CALCULATION MANUAL (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm/trip setpoints, and in the conduct of the Radiological Environmental Monitoring Program. The ODCM shall also contain (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by Section 6.8.4 and (2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports required by Specifications 6.9.1.7 and 6.9.1.8.

OPERABLE - OPERABILITY 1.25 A system, subsystem, train, component or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified function(s) and when all necessary attendant instrumentation, controls, electrical power, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its function(s) are also capable of performing their related support function(s).

LIMERICK - UNIT 1 1-4 Amendment No. 48, 66, 73, 187

1.0 DEFINITIONS The following terms are defined so that uniform interpretation of these specifications may be achieved. The defined terms appear in capitalized type and shall be applicable throughout these Technical Specifications.

ACTION 1.1 ACTION shall be that part of a Specification which prescribes remedial measures required under designated conditions.

AVERAGE PLANAR EXPOSURE 1.2 The AVERAGE PLANAR EXPOSURE shall be applicable to a specific planar height and is equal to the sum of the exposure of all the fuel rods in the specified bundle at the specified height divided by the number of fuel rods in the fuel bundle.

AVERAGE PLANAR LINEAR HEAT GENERATION RATE 1.3 The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) shall be applicable to a specific planar height and is equal to the sum of the LINEAR HEAT GENERATION RATES for all the fuel rods in the specified bundle at the specified height divided by the number of fuel rods in the fuel bundle.

CHANNEL CALIBRATION 1.4 A CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel output such that it responds with the necessary range and accuracy to known values of the parameter which the channel monitors. The CHANNEL CALIBRATION shall encompass the entire channel including the sensor and alarm and/or trip functions, and shall include the DOOGHYLFHVLQWKHFKDQQHOUHTXLUHGIRU

23(5$%,/,7<DQGVKDOOLQFOXGHWKHCHANNEL FUNCTIONAL TEST. The CHANNEL CALIBRATION may be performed by any series of sequential, overlapping or total channel steps such that the entire channel is calibrated, and each step must be performed within the Frequency in the Surveillance Frequency Control Program for the devices included in the step.

CHANNEL CHECK 1.5 A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. This determination shall include, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrument channels measuring the same parameter.

CHANNEL FUNCTIONAL TEST 1.6 A CHANNEL FUNCTIONAL TEST shall be:

a.

Analog channels - the injection of a simulated signal into the channel

as close to the sensor as practicable to verify OPERABILITY including

alarm and/or trip functions and channel failure trips.RIDOOGHYLFHV

LQWKHFKDQQHOUHTXLUHGIRUFKDQQHO23(5$%,/,7<

b.

Bistable channels - the injection of a simulated signal into the sensor

to verify OPERABILITY including alarm and/or trip functions.RIDOO

GHYLFHVLQWKHFKDQQHOUHTXLUHGIRU23(5$%,/,7<

The CHANNEL FUNCTIONAL TEST may be performed by any series of sequential, overlapping or total channel steps such that the entire channel is tested, and each step must be performed within the Frequency in the Surveillance Frequency Control Program for the devices included in the step.

LIMERICK - UNIT 2 1-1 Amendment No. 206

DEFINITIONS LOGIC SYSTEM FUNCTIONAL TEST 1.20 A LOGIC SYSTEM FUNCTIONAL TEST shall be a test of all logic components, i.e., all relays and contacts, all trip units, solid state logic elements, etc, UHTXLUHGIRU23(5$%,/,7<of a logic circuit, from DVFORVH

WRWKHsensor DVSUDFWLFDOXSWREXWQRWLQFOXGLQJthrough and including the actuated device, to verify OPERABILITY. The LOGIC SYSTEM FUNCTIONAL TEST may be performed by any series of sequential, overlapping or total system steps such that the entire logic system is tested.

LOW (POWER) TRIP SETPOINT (LTSP) 1.20a The low power trip setpoint associated with the Rod Block Monitor (RBM) rod block trip setting applicable between 30% and 65% reactor thermal power.

1.21 (Deleted)

MEMBER(S) OF THE PUBLIC 1.22 MEMBER OF THE PUBLIC means any individual except when that individual is receiving an occupational dose.

MAPFAC(F)-(MAPLHGR FLOW FACTOR) 1.22a A core flow dependent multiplication factor used to flow bias the standard Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) limit.

MAPFAC(P)-(POWER DEPENDENT MAPLHGR MULTIPLIER) 1.22b A core power dependent multiplication factor used to power bias the standard Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) limit.

MINIMUM CRITICAL POWER RATIO (MCPR) 1.23 The MINIMUM CRITICAL POWER RATIO (MCPR) shall be the smallest CPR which exists in the core (for each class of fuel). Associated with the minimum critical power ratio is a core flow dependent (MCPR(F)) and core power dependent (MCPR(P)) minimum critical power ratio.

OFFSITE DOSE CALCULATION MANUAL 1.24 The OFFSITE DOSE CALCULATION MANUAL (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm/trip setpoints, and in the conduct of the Radiological Environmental Monitoring Program. The ODCM shall also contain (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by Section 6.8.4 and (2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports required by Specifications 6.9.1.7 and 6.9.1.8.

OPERABLE - OPERABILITY 1.25 A system, subsystem, train, component or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified function(s) and when all necessary attendant instrumentation, controls, electrical power, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its function(s) are also capable of performing their related support function(s).

LIMERICK - UNIT 2 1-4 Amendment No. 11,35,48,148, 153