SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 1
DrawingNo.166D8142Rev.KUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.J;FM9006.1082017008;08312017;JA Rev.K;FM9006.1012021014;01252021;JA Note:Rev.KalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
D4 NOTES
TRIANGLENOTE4 TORQUETO35lbft(47Nm)LUBRICATED
<Revisedspecifiedrequirement>
TORQUETO17lbft(23Nm)LUBRICATED Revisedtoreduceexcessivetorquevaluedesignatedandtobeinlinewith3/816screws D4 NOTES
NOTE5 USEAHIGHCAPACITYRUBBERPAD.50INTHICK,ONBASETOSITTHEASSEMBLY (CASKANDIMPACTLIMITERS).MADEFROMMCMASTERCARR#5940K53OR EQUIVALENT.
<Addedtoendofnote>
OREQUIVALENT.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Thesecomponentsarenotimportantto safety;andappearonlyasanoteontheCertificationDrawingsandnoSafetyClassificationis listed.
B5 PARTLIST MATERIAL Item8 HEXORHEX FLANGEBOLTS 3/816UNCX5/8 LG ASMESA193/ASTMA193,GRADEB6(UNSS41000)
<Addedtoendofmaterial>
(UNSS41000)ORNITRONIC60PERASMESA193/ASTMA193,GRADEB8S(UNSS21800)
Justification:Additionofalternatematerial;usedinShippingCageScrewanalysis;SARFM9054 Rev.JSection2.5.3.1.2.
Sheet2of2
NoChange
DrawingNo.105E9722Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2 B1 REVISIONS Rev.I;FM9006.1032015011;03232015;JA Rev.J;FM9006.1012021013;01252021;JA Note:Rev.JalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
C5 PARTLIST
MATERIAL Item10 POLYURETHANE FOAM FR3720
<Correctionoftypographicalerror>
FR3718 ProperdesignationfromSARFM9054(Tables214and215)
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 2
DrawingNo.105E9722Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2 C2 PARTLIST SAFETY CLASSIFICATION Item12 LUG A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:TheJHookConnectorsareusedtosecuretheCaskAssemblywithintheImpact LimiterAssembliesandserveasanoperationalsupportfunction.Thesehaveaminorimpacton safety.Theirfailureormalfunctionwouldnotsignificantlyreducethepackagingeffectiveness andwouldnotlikelycreateasituationadverselyaffectingpublichealthorsafety.Duetothe redundancyoftheJHookConnectorsandtheVersatileendWebbingAssemblies(AOS025 only),thesecomponentscanbeclassifiedasSafetyClassificationB.
C2 PARTLIST SAFETY CLASSIFICATION Item13 PIN A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:SeeItem12,above C2 PARTLIST SAFETY CLASSIFICATION Item14 JHOOK A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:SeeItem12,above C2 PARTLIST SAFETY CLASSIFICATION Item15 HEXNUT A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:SeeItem12,above C2 PARTLIST SAFETY CLASSIFICATION Item19 LUG A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:SeeItem12,above C2 PARTLIST SAFETY CLASSIFICATION Item20 PIN A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:SeeItem12,above Sheet2of2
NoChanges
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 3
DrawingNo.166D8143Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.I;FM9006.1082017009;08312017;JA Rev.J;FM9006.1012021015;01252021;JA Note:Rev.JalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
D4 NOTES
TRIANGLENOTE 11 COMPACT400SERIESSTAINLESSSTEELWOOL,GRADEFINE,AND/ORSHIM300 SERIESSTAINLESSSTEELPLATEINTOOPENGAPSDURINGASSEMBLY.
<Addedtoendofnote>
DURINGASSEMBLY.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Sincethethermalpropertiesofthestainless steelwoolandshimplatesareveryconservativelyrepresentedintheanalysis,these componentsarenotimportanttosafety;andappearonlyasanoteontheCertification DrawingsandnoSafetyClassificationislisted.
B3 PARTLIST SAFETY CLASSIFICATION Item1 CASKOUTER SHELL A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:Thecomponentisapartofthepackageoutershellandcanbedesignatedas SafetyClassificationB;perSARFM9054Table28,ApplicableCodesandStandardsfor Design,FabricationandTestingoftheAOSTransportPackagingSystem.
B3 PARTLIST SAFETY CLASSIFICATION Item15 PORTPLUG SPACER A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortPlugSpacersarenotapartofthecontainmentsystem,anddonotrequire anAorBSafetyClassification.
A3 PARTLIST SAFETY CLASSIFICATION Item18 TRUNNION COVERSCREW B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:TrunnionCoverScrewsareonlyusedtosecuretheTrunnionCovertothe Trunnion.Asfailurewillnotallowbreachofthecontainmentorshielding,SafetyClassification Cisanappropriatedesignationforthispart.
A3 PARTLIST SAFETY CLASSIFICATION Item20 THREADED INSERT B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ThreadedInsertsareonlyusedtosecuretheTrunnionstotheCaskAssembly usingtheTrunnionScrewsforliftingpurposes.ThreadedInsertshaveaverylimitedsafety functionduringtransportation;andfailurewillnotallowbreachofthecontainmentor shielding,SafetyClassificationCisanappropriatedesignationforthispart.
A3 PARTLIST SAFETY CLASSIFICATION Item22 PORTSOCKET SCREW A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortSocketScrewsarenotapartofthecontainmentsystem;theypreventdebris fromenteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 4
DrawingNo.166D8143Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
A3 PARTLIST SAFETY CLASSIFICATION Item23 BOTTOMPLATE A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:Thecomponentsareapartofthepackageoutershellandcanbedesignatedas SafetyClassificationB;perSARFM9054Table28,ApplicableCodesandStandardsfor Design,FabricationandTestingoftheAOSTransportPackagingSystem.
A3 PARTLIST SAFETY CLASSIFICATION Item27 PORTCOVER
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortCoverspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
A3 PARTLIST SAFETY CLASSIFICATION Item28 ORING
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ORingspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
A8 PARTLIST DESCRIPTION Item34 LIDSEAL,OPTION LIDSEAL,OPTION
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
LIDSEAL,OPTION(SPECIALFORMCONTENTSONLY)
Justification:ElastomericsealisforSpecialFormContentOnlywheretheproductprovidesfor selfcontainment.
A3 PARTLIST SAFETY CLASSIFICATION Item34 LIDSEAL,OPTION A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ElastomericsealisforSpecialFormContentOnlywheretheproductprovidesfor selfcontainment.
Sheet2of2
NoChange
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 5
DrawingNo.183C8485Rev.HUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges
DrawingNo.105E9718Rev.KUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.J;FM9006.1082017005;08312017;JA Rev.K;FM9006.1012021016;01252021;JA Note:Rev.JalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
A1 TITLEBLOCK CERTIFICATIONDRAWINGAOS050APACKAGEASSEMBLY
<Correcttypographicalerror>
CERTIFICATIONDRAWINGAOS050APACKAGINGASSEMBLY G4 NOTES
TRIANGLENOTE4 TORQUETO35lbft(47Nm)LUBRICATED
<Revisedspecifiedrequirement>
TORQUETO17lbft(23Nm)LUBRICATED Revisedtoreduceexcessivetorquevaluedesignatedandtobeinlinewith3/816screws G4 NOTES
NOTE5 USEAHIGHCAPACITYRUBBERPAD.50INTHICK,ONBASETOSITTHEASSEMBLY (CASKANDIMPACTLIMITERS).MADEFROMMCMASTERCARR#5940K56OR EQUIVALENT.
<Addedtoendofnote>
OREQUIVALENT.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Thesecomponentsarenotimportantto safety;andappearonlyasanoteontheCertificationDrawingsandnoSafetyClassificationis listed.
D5 PARTLIST MATERIAL Item8 HEXORHEX FLANGEBOLTS 3/816UNCX5/8 LG ASMESA193/ASTMA193,GRADEB6(UNSS41000)
<Addedtoendofmaterial>
(UNSS41000)ORNITRONIC60PERASMESA193/ASTMA193,GRADEB8S(UNSS21800)
Justification:Additionofalternatematerial;usedinShippingCageScrewanalysis;SARFM9054 Rev.JSection2.5.3.1.3.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 6
DrawingNo.105E9718Rev.KUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
D1 PARTLIST SAFETY CLASSIFICATION Item10 TURNBUCKLE A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:TheImpactLimiterAssemblyTurnbucklesareusedtosecuretheCaskAssembly withintheImpactLimiterAssembliesandserveasanoperationalsupportfunction.Thesehave aminorimpactonsafety.Theirfailureormalfunctionwouldnotsignificantlyreducethe packagingeffectivenessandwouldnotlikelycreateasituationadverselyaffectingpublichealth orsafety.DuetotheredundancyoftheImpactLimiterTurnbucklesandtheandtheTieDown Turnbuckles,thesecomponentscanbeclassifiedasSafetyClassificationB.
D1 PARTLIST SAFETY CLASSIFICATION Item11 TURNBUCKLE MCMASTERCARR 3001T61 A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:TieDownAssemblyTurnbucklesareusedtosecuretheCask/ImpactLimiter AssemblytotheTransportPalletinsidetheShippingCage.Astheseitemscanbeconsidered tiedownhardware,SafetyClassificationBisanappropriatedesignationforthispart.
Sheet2of2 A1 TITLEBLOCK CERTIFICATIONDRAWINGAOS050APACKAGEASSEMBLY
<Correcttypographicalerror>
CERTIFICATIONDRAWINGAOS050APACKAGINGASSEMBLY
DrawingNo.166D8138Rev.IUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges
DrawingNo.166D8137Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.I;FM9006.1082017007;08312017;JA Rev.J;FM9006.1012021017;01252021;JA Note:Rev.JalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 7
DrawingNo.166D8137Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
C3 NOTES
TRIANGLENOTE 11 COMPACT400SERIESSTAINLESSSTEELWOOL,GRADEFINE,AND/ORSHIM300 SERIESSTAINLESSSTEELPLATEINTOOPENGAPSDURINGASSEMBLY.
<Addedtoendofnote>
DURINGASSEMBLY.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Sincethethermalpropertiesofthestainless steelwoolandshimplatesareveryconservativelyrepresentedintheanalysis,these componentsarenotimportanttosafety;andappearonlyasanoteontheCertification DrawingsandnoSafetyClassificationislisted.
B3 PARTLIST SAFETY CLASSIFICATION Item1 CASKOUTER SHELL A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:Thecomponentisapartofthepackageoutershellandcanbedesignatedas SafetyClassificationB;perSARFM9054Table28,ApplicableCodesandStandardsfor Design,FabricationandTestingoftheAOSTransportPackagingSystem.
B3 PARTLIST SAFETY CLASSIFICATION Item12 SOCKETSET SCREW B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:SocketSetScrewsarenotapartofthecontainmentsystem;theypreventdebris fromenteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.
B3 PARTLIST SAFETY CLASSIFICATION Item15 PORTPLUG SPACER A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortPlugSpacersarenotapartofthecontainmentsystem,anddonotrequire anAorBSafetyClassification.
A3 PARTLIST SAFETY CLASSIFICATION Item19 TRUNNION COVERSCREW B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:TrunnionCoverScrewsareonlyusedtosecuretheTrunnionCovertothe Trunnion.Asfailurewillnotallowbreachofthecontainmentorshielding,SafetyClassification Cisanappropriatedesignationforthispart.
A3 PARTLIST SAFETY CLASSIFICATION Item22 THREADED INSERT B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ThreadedInsertsareonlyusedtolifttheCaskLid.ThreadedInsertshaveavery limitedsafetyfunctionduringtransportation;andfailurewillnotallowbreachofthe containmentorshielding,SafetyClassificationCisanappropriatedesignationforthispart.
A3 PARTLIST SAFETY CLASSIFICATION Item23 BOTTOMPLATE A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:Thecomponentsareapartofthepackageoutershellandcanbedesignatedas SafetyClassificationB;perSARFM9054Table28,ApplicableCodesandStandardsfor Design,FabricationandTestingoftheAOSTransportPackagingSystem.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 8
DrawingNo.166D8137Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
A3 PARTLIST SAFETY CLASSIFICATION Item26 PORTCOVER
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortCoverspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
A3 PARTLIST SAFETY CLASSIFICATION Item27 ORING
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ORingspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
A8 PARTLIST DESCRIPTION Item29 LIDSEAL,OPTION LIDSEAL,OPTION
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
LIDSEAL,OPTION(SPECIALFORMCONTENTSONLY)
Justification:ElastomericsealisforSpecialFormContentOnlywheretheproductprovidesfor selfcontainment.
A3 PARTLIST SAFETY CLASSIFICATION Item29 LIDSEAL,OPTION A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ElastomericsealisforSpecialFormContentOnlywheretheproductprovidesfor selfcontainment.
Sheet2of2
NoChange
DrawingNo.183C8519Rev.AUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 9
DrawingNo.105E9711Rev.LUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet2of2 B1 REVISIONS Rev.K;FM9006.1072018001;07122018;JA Rev.L;FM9006.1012021018;01252021;JA Note:Rev.JalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
A1 TITLEBLOCK CERTIFICATIONDRAWINGAOS050APACKAGEASSEMBLY
<Correcttypographicalerror>
CERTIFICATIONDRAWINGAOS050APACKAGINGASSEMBLY G4 NOTES
NOTE7 USEAHIGHCAPACITYRUBBERPAD.50INTHICK,ONBASETOSITTHEASSEMBLY (CASKANDIMPACTLIMITERS).MADEFROMMCMASTERCARR#5940K56OR EQUIVALENT.
<Addedtoendofnote>
OREQUIVALENT.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Thesecomponentsarenotimportantto safety;andappearonlyasanoteontheCertificationDrawingsandnoSafetyClassificationis listed.
E1 PARTLIST SAFETY CLASSIFICATION Item4 TURNBUCKLE, MCMASTERCARR 3001T73 A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
B Justification:TieDownAssemblyTurnbucklesareusedtosecuretheCask/ImpactLimiter AssemblytotheTransportPalletinsidetheShippingCage.Astheseitemscanbeconsideredtie downhardware,SafetyClassificationBisanappropriatedesignationforthispart.
Sheet2of2 A1 TITLEBLOCK CERTIFICATIONDRAWINGAOS100PACKAGEASSEMBLY
<Correcttypographicalerror>
CERTIFICATIONDRAWINGAOS100PACKAGINGASSEMBLY
DrawingNo.105E9713Rev.JUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 10 DrawingNo.105E9712Rev.MUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of3 B1 REVISIONS Rev.L;FM9006.1102018001;10262018;JA Rev.M;FM9006.1012021019;01252021;JA Note:Rev.MalsoshowninTitleBlock(Sheet1of3;Sheet2of3;andSheet3of3);andFM numbershowninbottomrighthandcornerofpage(Sheet1of3;Sheet2of3;andSheet3of3)
G4 NOTES
TRIANGLENOTE 10 COMPACT400SERIESSTAINLESSSTEELWOOL,GRADEFINE,AND/ORSHIM300 SERIESSTAINLESSSTEELPLATEINTOOPENGAPSDURINGASSEMBLY.
<Addedtoendofnote>
DURINGASSEMBLY.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Sincethethermalpropertiesofthestainless steelwoolandshimplatesareveryconservativelyrepresentedintheanalysis,these componentsarenotimportanttosafety;andappearonlyasanoteontheCertification DrawingsandnoSafetyClassificationislisted.
C2 PARTLIST SAFETY CLASSIFICATION Item17 THREADED INSERT B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ThreadedInsertsareonlyusedtolifttheCaskLid.ThreadedInsertshaveavery limitedsafetyfunctionduringtransportation;andfailurewillnotallowbreachofthe containmentorshielding,SafetyClassificationCisanappropriatedesignationforthispart.
C2 PARTLIST SAFETY CLASSIFICATION Item21 THREADED INSERT B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ThreadedInsertsareonlyusedtolifttheCaskLidPlug.ThreadedInsertshavea verylimitedsafetyfunctionduringtransportation;andfailurewillnotallowbreachofthe containmentorshielding,SafetyClassificationCisanappropriatedesignationforthispart.
C2 PARTLIST SAFETY CLASSIFICATION Item23 TRUNNION COVERSCREWS B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:TrunnionCoverScrewsareonlyusedtosecuretheTrunnionCovertothe Trunnion.Asfailurewillnotallowbreachofthecontainmentorshielding,SafetyClassification Cisanappropriatedesignationforthispart.
B2 PARTLIST SAFETY CLASSIFICATION Item31 PORTPLUG SPACER A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortPlugSpacersarenotapartofthecontainmentsystem,anddonotrequirean AorBSafetyClassification.
A2 PARTLIST SAFETY CLASSIFICATION Item18and27 PORTCOVER
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortCoverspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 11 DrawingNo.105E9712Rev.MUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
A2 PARTLIST SAFETY CLASSIFICATION Item19&29 ORING
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ORingspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
C2 PARTLIST SAFETY CLASSIFICATION Item26 PIPEPLUG B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PipePlugsarenotapartofthecontainmentsystem;theypreventdebrisfrom enteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.
C5 PARTLIST MATERIAL Item26 PIPEPLUG ASMESA182/ASTMA182,GRADEF304ORF316,ASMESA479/ASTMA479,TYPE 304OR316
<AddOptionalmaterialdescription>
OR316;OROPTIONAL-MCMASTERCARRPARTNO.9171K251,1/827NPTPRECISION EXTREMEPRESSUREBRASSPIPEFITTING,PLUGWITHHEXDRIVE,ANSI/ASMEB1.20.1 Justification:PipePlugsarenotapartofthecontainmentsystem;theypreventdebrisfrom enteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.Assuch, anoptionalmaterialisprovidedtoreducewearandtearonthethreadsintheCaskAssembly.
Sheet2of3 E4 DETAILK
Item18and27 TORQUE55lbft(75Nm)(LUBASREQUIRED)
<Revisedspecifiedrequirement>
TORQUE25lbft(34Nm)(LUBASREQUIRED)
Justification:Revisedtoreduceexcessivetorquevaluedesignated.PortCoversareoutsidethe containmentboundary.
Sheet3of3 E4 DETAILY
Item18and27 TORQUE55lbft(75Nm)(LUBASREQUIRED)
<Revisedspecifiedrequirement>
TORQUE25lbft(34Nm)(LUBASREQUIRED)
Justification:Revisedtoreduceexcessivetorquevaluedesignated.PortCoversareoutsidethe containmentboundary.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 12 DrawingNo.105E9719Rev.MUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
Sheet1of2 B1 REVISIONS Rev.L;FM9006.1102018002;10262018;JA Rev.M;FM9006.1012021020;01252021;JA Note:Rev.MalsoshowninTitleBlock(Sheet1of2;andSheet2of2);andFMnumbershown inbottomrighthandcornerofpage(Sheet1of2;andSheet2of2)
G4 NOTES
TRIANGLENOTE 10 COMPACT400SERIESSTAINLESSSTEELWOOL,GRADEFINE,AND/ORSHIM300 SERIESSTAINLESSSTEELPLATEINTOOPENGAPSDURINGASSEMBLY.
<Addedtoendofnote>
DURINGASSEMBLY.MATERIALSAFETYCLASSIFICATIONISNITS.
Justification:IdentificationofSafetyClassification.Sincethethermalpropertiesofthestainless steelwoolandshimplatesareveryconservativelyrepresentedintheanalysis,these componentsarenotimportanttosafety;andappearonlyasanoteontheCertification DrawingsandnoSafetyClassificationislisted.
D6 PARTLIST MATERIAL Item5 TRUNION ASMESA240/ASTMA240,TYPE304OR316
<Correctionoftypographicalerror-replacewithcorrectmaterialspecification>
ASMESA479/ASTMA479,TYPE304OR316 ProperdesignationfromSARFM9054(Tables218)
C2 PARTLIST SAFETY CLASSIFICATION Item17 THREADED INSERT B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ThreadedInsertsareonlyusedtolifttheCaskLid.ThreadedInsertshaveavery limitedsafetyfunctionduringtransportation;andfailurewillnotallowbreachofthe containmentorshielding,SafetyClassificationCisanappropriatedesignationforthispart.
C2 PARTLIST SAFETY CLASSIFICATION Item23 TRUNNION COVERSCREWS B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:TrunnionCoverScrewsareonlyusedtosecuretheTrunnionCovertothe Trunnion.Asfailurewillnotallowbreachofthecontainmentorshielding,SafetyClassification Cisanappropriatedesignationforthispart.
B2 PARTLIST SAFETY CLASSIFICATION Item31 PORTPLUG SPACER A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortPlugSpacersarenotapartofthecontainmentsystem,anddonotrequirean AorBSafetyClassification.
A2 PARTLIST SAFETY CLASSIFICATION Item18and27 PORTCOVER
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PortCoverspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 13 DrawingNo.105E9719Rev.MUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.J)
Whatitis(Rev.K)
A2 PARTLIST SAFETY CLASSIFICATION Item19&29 ORING
B
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:ORingspreventdebrisfromenteringthePortPlugarea,arenotapartofthe containmentsystem.
Thesehaveaminorimpactonsafety,theirfailureormalfunctionwouldnotreducethe packagingeffectivenessandwouldnotbelikelytocreateasituationadverselyaffectingpublic healthandsafety;anddonotrequireanAorBSafetyClassification.
C2 PARTLIST SAFETY CLASSIFICATION Item26 PIPEPLUG A
<DowngradedbasedonguidanceprovidedinNUREG/CR6407>
C Justification:PipePlugsarenotapartofthecontainmentsystem;theypreventdebrisfrom enteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.
C5 PARTLIST MATERIAL Item26 PIPEPLUG ASMESA182/ASTMA182,GRADEF304ORF316,ASMESA479/ASTMA479,TYPE 304OR316
<AddOptionalmaterialdescription>
OR316;OROPTIONAL-MCMASTERCARRPARTNO.9171K251,1/827NPTPRECISION EXTREMEPRESSUREBRASSPIPEFITTING,PLUGWITHHEXDRIVE,ANSI/ASMEB1.20.1 Justification:PipePlugsarenotapartofthecontainmentsystem;theypreventdebrisfrom enteringtheCaskAnnulusarea;anddonotrequireanAorBSafetyClassification.Assuch, anoptionalmaterialisprovidedtoreducewearandtearonthethreadsintheCaskAssembly.
Sheet2of2 E4 DETAILK
Item18and27 TORQUE55lbft(75Nm)(LUBASREQUIRED)
<Revisedspecifiedrequirement>
TORQUE25lbft(34Nm)(LUBASREQUIRED)
Justification:Revisedtoreduceexcessivetorquevaluedesignated.PortCoversareoutsidethe containmentboundary.
DrawingNo.183C8491Rev.IUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges
SARFM9054,Rev.J(re.Table15)CERTIFICATIONDRAWINGUPDATES January29,2021 14 DrawingNo.183C8518Rev.BUpdatesTrackingdrawingzone,heading/item,paragraphnumber,linenumber;whatitwas,whatitisandjustification(ifneeded)
Dwg.
Zone Heading/
Item Para#/Item Line#/Item Whatitwas(Rev.I)
Whatitis(Rev.J)
Sheet1of2
NoChanges
Sheet2of2
NoChanges